  1. The Effects of Wet Compression by the Electronic Expansion Valve Opening on the Performance of a Heat Pump System

    Directory of Open Access Journals (Sweden)

    Kyoungjin Seong

    2017-03-01

    Full Text Available In this study, by controlling the Electronic Expansion Valve opening, the influence of wet compression on a heat pump system was experimentally investigated in different heating conditions. The results demonstrate that the discharge temperature decreased and the mass flow rate increased, due to quality of the rising liquid droplets. It was also found that the heating capacity and power input of wet compression increased more than that of dry compression, with a superheat of 10 °C. The maximum COP (Coefficient of Performance exists at a specific quality of ca. 0.94 to 0.90, as the power input in the region of wet compression is proportionally larger than the increase in the heating capacity, according to the decreasing quality. When the Entering Water Temperature of the Outdoor Heat Exchanger was 10 °C, 5 °C, and 0 °C, the COP increased by a maximum of ca. 12.4%, 10.6%, and 10.2%, respectively, in comparison to the superheat of 10 °C. In addition, the superheat at the discharge line is proposed as a proper controlling parameter to adjust the quality at the suction line, by varying the opening of the expansion valve during wet compression.

  2. Frostless heat pump having thermal expansion valves

    Science.gov (United States)

    Chen, Fang C [Knoxville, TN; Mei, Viung C [Oak Ridge, TN

    2002-10-22

    A heat pump system having an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant and further having a compressor, an interior heat exchanger, an exterior heat exchanger, a heat pump reversing valve, an accumulator, a thermal expansion valve having a remote sensing bulb disposed in heat transferable contact with the refrigerant piping section between said accumulator and said reversing valve, an outdoor temperature sensor, and a first means for heating said remote sensing bulb in response to said outdoor temperature sensor thereby opening said thermal expansion valve to raise suction pressure in order to mitigate defrosting of said exterior heat exchanger wherein said heat pump continues to operate in a heating mode.

  3. EVALUATION OF A MULTIFUNCTIONAL VALVE ASSEMBLY IN A DIRECT EXPANSION REFRIGERATION SYSTEM REPORT

    Science.gov (United States)

    The report describes the performance, including energy consumption, of a refrigeration system incorporating a multifunctional valve (MXV assembly). The MXV assembly (consisting of additional liquid line, an XTC valve, and a larger thermostatic expansion valve) was installed on al...

  4. Hermetic compressor and block expansion valve in refrigeration performance

    Science.gov (United States)

    Santoso, Budi; Susilo, Didik Djoko; Tjahjana, D. D. D. P.

    2016-03-01

    Vehicle cabin in tropical countries requires the cooling during the day for comfort of passengers. Air conditioning machine is commonly driven by an internal combustion engine having a great power, which the conventional compressor is connected to crank shaft. The stage of research done is driving the hermetic compressor with an electric motor, and using block expansion valve. The HFC-134a was used as refrigerant working. The primary parameters observed during the experiment are pressure, temperature, and power consumption for different cooling capacities. The results show that the highest coefficient of performance (COP) and the electric power of system are 6.3 and 638 Watt, respectively.

  5. Investigation of charges for thermostatic expansion valves containing condensable and non condensable gas

    DEFF Research Database (Denmark)

    Langmaack, Lasse Nicolai; Knudsen, Hans-Jørgen Høgaard

    2006-01-01

    The bulb of a thermostatic expansion valve (TXV) is basically a temperature-pressure converter. It senses the temperature at the outlet of the evaporator, and the substance in the bulb (charge) generates the corresponding saturation pressure inside the bulb. The aim of the work presented...

  6. Heat transfer from the evaporator outlet to the charge of thermostatic expansion valves

    DEFF Research Database (Denmark)

    Langmaack, Lasse Nicolai; Knudsen, Hans-Jørgen Høgaard

    2006-01-01

    The bulb of a thermostatic expansion valve (TXV) is basically a temperature-pressure converter. It senses the temperature at the outlet of the evaporator, and the substance in the bulb (charge) generates the corresponding saturation pressure inside the bulb. The bulb is mounted on the evaporator...... outlet with a special mounting strap. The heat transfer is quite complex because it takes place both directly through the contact points between bulb and pipe and indirectly through the mounting strap The TXV has to react to temperature changes at the evaporator outlet. Therefore, the dynamic behavior...... of the valve (and thereby the whole refrigeration system) depends greatly on the heat transfer between the evaporator outlet tube and the charge in the bulb. In this paper a model for the overall heat transfer between the pipe and the charge is presented. Geometrical data and material properties have been kept...

  7. Fuzzy Pattern Classification Based Detection of Faulty Electronic Fuel Control (EFC Valves Used in Diesel Engines

    Directory of Open Access Journals (Sweden)

    Umut Tugsal

    2014-05-01

    Full Text Available In this paper, we develop mathematical models of a rotary Electronic Fuel Control (EFC valve used in a Diesel engine based on dynamic performance test data and system identification methodology in order to detect the faulty EFC valves. The model takes into account the dynamics of the electrical and mechanical portions of the EFC valves. A recursive least squares (RLS type system identification methodology has been utilized to determine the transfer functions of the different types of EFC valves that were investigated in this study. Both in frequency domain and time domain methods have been utilized for this purpose. Based on the characteristic patterns exhibited by the EFC valves, a fuzzy logic based pattern classification method was utilized to evaluate the residuals and identify faulty EFC valves from good ones. The developed methodology has been shown to provide robust diagnostics for a wide range of EFC valves.

  8. Development of an Electronically Controlled Self-Teaching Lift Valve Family

    OpenAIRE

    Goenechea, Eneko

    2016-01-01

    Other than mobile hydraulics and high voltage switchgears, Bucher Hydraulics is also involved in the less-known area of hydraulic lifts. In fact, Bucher Hydraulics did invent the electronically controlled lift valve in the 1970s. Since then, Bucher Hydraulics developed a wide line of products for hydraulic elevators, such as valves and power units. In 2012, this valve family included various sizes, pressure ranges, systems with constant motor speeds, inverter-driven motors, energy-efficient s...

  9. Dosimetric evaluation in mammary glands radiotherapy using expansive prosthesis with magnetic valve; Avaliacao dosimetrica de tratamentos de radioterapia de mama usando proteses expansivas com valvula magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Lizar, J.C.; Pavoni, J.F.; Baffa, O. [Universidade de Sao Paulo (USP), Ribeirao Preto (Brazil); Krutman, Y. [Rabin Medical Center (RMC), (Israel)

    2016-07-01

    This work aims to verify the influence on dose distribution that the expansive prosthesis (SILIMED/470), containing a magnetic valve, generates in radiotherapy postoperative treatment of patients who have undergone mastectomy. (author)

  10. Electron-electron interaction, weak localization and spin valve effect in vertical-transport graphene devices

    Energy Technology Data Exchange (ETDEWEB)

    Long, Mingsheng; Gong, Youpin; Wei, Xiangfei; Zhu, Chao; Xu, Jianbao; Liu, Ping; Guo, Yufen; Li, Weiwei; Liu, Liwei, E-mail: lwliu2007@sinano.ac.cn [Key Laboratory of Nanodevices and Applications-CAS and Collaborative Innovation Center of Suzhou Nano Science and Technology, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (CAS), Suzhou 215123 (China); Liu, Guangtong [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-04-14

    We fabricated a vertical structure device, in which graphene is sandwiched between two asymmetric ferromagnetic electrodes. The measurements of electron and spin transport were performed across the combined channels containing the vertical and horizontal components. The presence of electron-electron interaction (EEI) was found not only at low temperatures but also at moderate temperatures up to ∼120 K, and EEI dominates over weak localization (WL) with and without applying magnetic fields perpendicular to the sample plane. Moreover, spin valve effect was observed when magnetic filed is swept at the direction parallel to the sample surface. We attribute the EEI and WL surviving at a relatively high temperature to the effective suppress of phonon scattering in the vertical device structure. The findings open a way for studying quantum correlation at relatively high temperature.

  11. Centrifuge pump control: valves or electronic driving?; Controle de bombas centrifugas: valvulas ou acionamento eletronico?

    Energy Technology Data Exchange (ETDEWEB)

    Bortoni, Edson da Costa [UNESP, Guaratingueta (Brazil); Tiago Filho, Geraldo Lucio; Silva, Benedito Claudio da [Escola Federal de Engenharia de Itajuba (EFEI), MG (Brazil)

    1998-10-01

    A methodology to estimate the energy economy potential is presented, resultant of the utilization, in the flow control in pumping systems of variable-speed electronic driving in place of throttling valves. The procedure comprehends the determination and analysis of the pump and installation curves, providing reliable data for a economical feasibility analysis.

  12. Negative Thermal Expansion and Ferroelectric Oxides in Electronic Device Composites

    Science.gov (United States)

    Trujillo, Joy Elizabeth

    Electronic devices increasingly pervade our daily lives, driving the need to develop components which have material properties that can be designed to target a specific need. The principle motive of this thesis is to investigate the effects of particle size and composition on three oxides which possess electronic and thermal properties essential to designing improved ceramic composites for more efficient, high energy storage devices. A metal matrix composite project used the negative thermal expansion oxide, ZrW2O 8, to offset the high thermal expansion of the metal matrix without sacrificing high thermal conductivity. Composite preparation employed a powder mixing technique to achieve easy composition control and homogenous phase distribution in order to build composites which target a specific coefficient of thermal expansion (CTE). A tailorable CTE material is desirable for overcoming thermomechanical failure in heat sinks or device casings. This thesis also considers the particle size effect on dielectric properties in a common ferroelectric perovskite, Ba1-xSrxTiO 3. By varying the Ba:Sr ratio, the Curie temperature can be adjusted and by reducing the particle size, the dielectric constant can be increased and hysteresis decreased. These conditions could yield anonymously large dielectric constants near room temperature. However, the ferroelectric behavior has been observed to cease below a minimum size of a few tens of nanometers in bulk or thin film materials. Using a new particle slurry approach, electrochemical impedance spectroscopy allows dielectric properties to be determined for nanoparticles, as opposed to conventional methods which measure only bulk or thin film dielectric properties. In this manner, Ba1-xSrxTiO3 was investigated in a new size regime, extending the theory on the ferroelectric behavior to < 10 nm diameter. This knowledge will improve the potential to incorporate high dielectric constant, low loss ferroelectric nanoparticles in many

  13. Development of a control system for compression and expansion cycles of critical valve for high vacuum systems

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Jyoti, E-mail: jagarwal@ipr.res.in; Sharma, H.; Patel, Haresh; Gangradey, R.; Lambade, Vrushabh

    2016-11-15

    Highlights: • Control system with feedback loop of pressure gauge is developed for measuring the life cycle of vacuum isolation valve. • GUI based software developed for easy use and handling of control system. • Control system tested with an experiment showcasing the capability of the control system. • Control system can operate valve based on pressure inside the chamber, which helps to know the degradation of sealing capabilities of valve. • Control system can monitor the total closing and opening time of valve, cycles and pressure inside the vessel. - Abstract: A control system with feedback loop is designed, developed and tested to monitor the life cycles of the axial valve and bellows used in vacuum valves. The control system monitors number of compression cycles of any bellow or closing and opening cycle of a valve. It also interfaces vacuum gauges or pressure gauges to get pressure values inside the system. To find life cycle of valve, the developed control and monitoring system is integrated with an axial valve experimental test set up. In this system, feedback from the vacuum gauge attached to valve enclosure, is given and the life cycle test is automated. This paper describes the control and monitoring system in details and briefs the experiment carried out for valve life cycle. The same system can be used for life cycle estimate for bellows. A suitable GUI is also developed to control the function of the components and resister the number of cycles.

  14. Collagen mineralization in human aortic valve stenosis: a field emission scanning electron microscopy and energy dispersive spectroscopy analysis.

    Science.gov (United States)

    Perrotta, Ida; Davoli, Mariano

    2014-08-01

    Abstract Calcific aortic stenosis is a slowly progressive disorder characterized by an important extracellular matrix remodeling with fibrosis and massive deposition of minerals (primarily calcium) in the valve leaflet. The main structural components of human aortic valve are the large, thick collagen bundles that withstand the diastolic loading. Collagen has been studied in a number of reports that aim to clarify the mechanisms underlying the structural deterioration of heart valve substitutes, however to date, little is known regarding the morphological interaction between collagen and mineral crystals in the calcifying tissue of native aortic valve. Here, we have analyzed a total of 12 calcified native aortic valves by using scanning electron microscopy (SEM) with Energy Dispersive X-Ray Analysis (EDX) to depict the morphological appearance of mineralized collagen and to determine the location of calcium phosphate minerals in the collagen matrix of the valve cusp. Our results demonstrate that crystals probably nucleate and grow in the interior of the collagen fibers in the absence of surface events.

  15. Low-rank spectral expansions of two electron excitations for the acceleration of quantum chemistry calculations.

    Science.gov (United States)

    Schwerdtfeger, Christine A; Mazziotti, David A

    2012-12-28

    Treatment of two-electron excitations is a fundamental but computationally expensive part of ab initio calculations of many-electron correlation. In this paper we develop a low-rank spectral expansion of two-electron excitations for accelerated electronic-structure calculations. The spectral expansion differs from previous approaches by relying upon both (i) a sum of three expansions to increase the rank reduction of the tensor and (ii) a factorization of the tensor into geminal (rank-two) tensors rather than orbital (rank-one) tensors. We combine three spectral expansions from the three distinct forms of the two-electron reduced density matrix (2-RDM), (i) the two-particle (2)D, (ii) the two-hole (2)Q, and the (iii) particle-hole (2)G matrices, to produce a single spectral expansion with significantly accelerated convergence. While the resulting expansion is applicable to any quantum-chemistry calculation with two-particle excitation amplitudes, it is employed here in the parametric 2-RDM method [D. A. Mazziotti, Phys. Rev. Lett. 101, 253002 (2008)]. The low-rank parametric 2-RDM method scales quartically with the basis-set size, but like its full-rank version it can capture multi-reference correlation effects that are difficult to treat efficiently by traditional single-reference wavefunction methods. Applications are made to computing potential energy curves of HF and triplet OH(+), equilibrium bond distances and frequencies, the HCN-HNC isomerization, and the energies of hydrocarbon chains. Computed 2-RDMs nearly satisfy necessary N-representability conditions. The low-rank spectral expansion has the potential to expand the applicability of the parametric 2-RDM method as well as other ab initio methods to large-scale molecular systems that are often only treatable by mean-field or density functional theories.

  16. Experimental evaluation on the use of capillary tube and thermostatic expansion valve with heat recovery hot spot water heater in air source refrigeration system

    Science.gov (United States)

    Aziz, Azridjal; Mainil, Rahmat Iman; Mainil, Afdhal Kurniawan; Saputra, Eko

    2017-01-01

    The present experimental evaluation has been carried out to investigate the use of capillary tube (CT) and thermostatic expansion valve (TEV) with heat recovery hot spot water heater (HRHSWH) in air source compression refrigeration system. CT and TEV are the two basic types of refrigerant expansion devices that most frequently used in compression refrigeration system, but the identified about HRHSWH in extant literature are limited. The HRHSWH is modified from residential refrigeration system. The heat exchanger coil as HRHSWH was bonded with the compressor discharge pipe line as counter-flow heat exchanger, then insulated and placed them into transparent acrylic box. Water from storage tank with 50L capacity is pumped using circulation pump to the HRHSWH and heating the water in storage tank. The system performance of those two expansion devices in compression refrigeration system are evaluated and compared between with or without modified using HRHSWH. Results show that refrigeration system using TEV performs better performance than CT using HRHSWH compared to standard refrigeration system (without HRHSWH). The use of TEV device in HRHSWH causes a slight decrease in compressor power 0.0198 kW (4%), where the COP increases around 20% higher than the CT device. The finding indicates that the use of HRHSWH generates free hot water for TEV and CT with temperature around 54.06°C and 55.78°C, respectively. In general, HRHSWH give better perfomance than standar refrigeration system.

  17. Perceived Barriers Of E-Commerce Expansion In The Electronic Manufacturing Companies In Malaysia

    OpenAIRE

    Syed Shah Alam; Ali Khatibi; Chloe Teah Woon Sim; Ahasanul Haque

    2011-01-01

    This study examines the major barriers that prevent manufacturing companies in Malaysia from adopting e-commerce. The major barriers of e-commerce expansion were security of payment and uncertain nature of legal and regulatory frameworks. Also the empirical findings reveal that doing business over Internet involves high start-up cost. In fact it is costly to set-up business electronically, because so many technological appliances are involved. Computers are quite expensive to buy limited main...

  18. Perpendicular hot electron spin-valve effect in a new magnetic field sensor: The spin-valve transistor

    NARCIS (Netherlands)

    Monsma, D.J.; Lodder, J.C.; Popma, T.J.A.; Dieny, B.

    1995-01-01

    A new magnetic field sensor is presented, based on perpendicular hot electron transport in a giant magnetoresistance (Co/Cu)4 multilayer, which serves as a base region of an n-silicon metal-base transistor structure. A 215% change in collector current is found in 500 Oe (77 K), with typical

  19. Improving search over Electronic Health Records using UMLS-based query expansion through random walks.

    Science.gov (United States)

    Martinez, David; Otegi, Arantxa; Soroa, Aitor; Agirre, Eneko

    2014-10-01

    Most of the information in Electronic Health Records (EHRs) is represented in free textual form. Practitioners searching EHRs need to phrase their queries carefully, as the record might use synonyms or other related words. In this paper we show that an automatic query expansion method based on the Unified Medicine Language System (UMLS) Metathesaurus improves the results of a robust baseline when searching EHRs. The method uses a graph representation of the lexical units, concepts and relations in the UMLS Metathesaurus. It is based on random walks over the graph, which start on the query terms. Random walks are a well-studied discipline in both Web and Knowledge Base datasets. Our experiments over the TREC Medical Record track show improvements in both the 2011 and 2012 datasets over a strong baseline. Our analysis shows that the success of our method is due to the automatic expansion of the query with extra terms, even when they are not directly related in the UMLS Metathesaurus. The terms added in the expansion go beyond simple synonyms, and also add other kinds of topically related terms. Expansion of queries using related terms in the UMLS Metathesaurus beyond synonymy is an effective way to overcome the gap between query and document vocabularies when searching for patient cohorts. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Detection of expansion at large angle grain boundaries using electron diffraction

    Science.gov (United States)

    Balluffi, R. W.; Bristowe, P. D.

    1984-02-01

    Lamarre and Sass (LS) (Scripta Metall. 17: 1141(1983) observed a grain boundary electron diffraction effect from a large angle twist boundary which is used to obtain the volume expansion at the grain boundary in a direction normal to it. The case where the intensity from the grain boundary region, is close to lattice reflections on the same element of the boundary diffraction lattice is considered. Analysis of this complex problem show that the simplified model of LS is misleading in this case.

  1. Detection of expansion at large angle grain boundaries using electron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Balluffi, R.W.; Bristowe, P.D.

    1984-02-01

    Lamarre and Sass (LS) (Scripta Metall. 17: 1141(1983)) observed a grain boundary electron diffraction effect from a large angle twist boundary which they claim can be used to obtain the volume expansion at the grain boundary in a direction normal to it. This paper considers the case where the intensity from the grain boundary region, is close to lattice reflections on the same element of the boundary diffraction lattice. Analysis of this complex problem show that the simplified model of LS is misleading in this case. (DLC)

  2. Spherical Harmonic Expansion Method for Coupled Electron-Phonon Boltzmann Transport

    Science.gov (United States)

    Santia, Marco; Albrecht, John

    2014-03-01

    Thermoelectric transport modeling often relies on independent Boltzmann transport equations (BTEs) for electrons and phonons which work best near equilibrium (linearized) and steady-state. Device design relies heavily on this baseline approximation. Monte Carlo methods can allow for complex physical interactions (e.g., anharmonicity) but their stochastic nature has practical limits. Distribution functions with wide disparities in population (e.g., ratios >108 between majority and minority carriers.[1]) are a computational challenge. We present a coupled BTE solver based on a k-space spherical harmonic expansion (SHE) of the distribution functions and eigenstates of electrons and phonons. The method is deterministic and allows for detailed treatments of scattering processes, yet ameliorates the issues with population disparity within phase space. We set the formalism and examine the accuracy of the SHE for phonon band structures, calculate scattering rates determined within that representation, and compare our preliminary results for distribution statistics in control examples such as thermal conductivity and drift velocity.

  3. Cell maceration scanning electron microscopy and computer-derived porosity measurements in assessment of connective tissue microstructure changes in the canine myxomatous mitral valve.

    Science.gov (United States)

    Han, R I; Impoco, G; Culshaw, G; French, A T; Black, A; Corcoran, B M

    2013-08-01

    Canine myxomatous mitral valve disease is associated with changes in the valve extracellular matrix (ECM). The aim of this study was to examine the use of cell macerated scanning electron microscopy (CMSEM) in evaluating ECM changes in a small sample of valves and to quantify these changes using computer-aided image analysis of sample porosity (a measure of structural disorganisation and collagen loss). The distinct layered structure of the de-cellularised matrix could be seen in the normal valve and there were marked changes in layers and ECM organisation as the disease progressed. Clearly visible and quantifiable, statistically significant changes were found in valve porosity across the entire leaflet thickness and particularly in the valve mid and distal zones. All of these changes are presumed to affect the mechanical function of the valve. In conclusion, CMSEM with computed image analysis can be used to visualise and measure tissue structural changes in a quasi-3-dimensional manner in normal and diseased tissues. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Electronic and optical properties of radiated oxide films on valve metals

    Energy Technology Data Exchange (ETDEWEB)

    Schultze, J.W.; Elfenthal, L.; Hansen, G.; Patzelt, T.; Siemensmeyer, B.; Thietke, J. (Duesseldorf Univ. (Germany, F.R.). Inst. fuer Physikalische Chemie und Elektrochemie)

    1990-01-01

    The electronic and optical properties of passive films are changed by radiation in different ways. Nuclear and electronic interaction must be discussed for heavy particles but only electronic interaction for {beta}- and {gamma}-radiation. Nuclear interaction means defect production and amorphization of the solid which can be detected by measurements of capacity, electron transfer reactions, photocurrents, UPS and XPS and reflection spectra. Various electrode reactions are enhanced which change the passive behavior. The electronic effect of radiation can be simulated by a focussed laser beam. Electron hole pairs are generated and separated in the electric field. Hole accumulation near the surface causes radiation induced oxide growth. (author).

  5. Influence of pre-injection control parameters on main-injection fuel quantity for an electronically controlled double-valve fuel injection system of diesel engine

    Science.gov (United States)

    Song, Enzhe; Fan, Liyun; Chen, Chao; Dong, Quan; Ma, Xiuzhen; Bai, Yun

    2013-09-01

    A simulation model of an electronically controlled two solenoid valve fuel injection system for a diesel engine is established in the AMESim environment. The accuracy of the model is validated through comparison with experimental data. The influence of pre-injection control parameters on main-injection quantity under different control modes is analyzed. In the spill control valve mode, main-injection fuel quantity decreases gradually and then reaches a stable level because of the increase in multi-injection dwell time. In the needle control valve mode, main-injection fuel quantity increases with rising multi-injection dwell time; this effect becomes more obvious at high-speed revolutions and large main-injection pulse widths. Pre-injection pulse width has no obvious influence on main-injection quantity under the two control modes; the variation in main-injection quantity is in the range of 1 mm3.

  6. Accelerating Atomic Orbital-based Electronic Structure Calculation via Pole Expansion plus Selected Inversion

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Lin; Chen, Mohan; Yang, Chao; He, Lixin

    2012-02-10

    We describe how to apply the recently developed pole expansion plus selected inversion (PEpSI) technique to Kohn-Sham density function theory (DFT) electronic structure calculations that are based on atomic orbital discretization. We give analytic expressions for evaluating charge density, total energy, Helmholtz free energy and atomic forces without using the eigenvalues and eigenvectors of the Kohn-Sham Hamiltonian. We also show how to update the chemical potential without using Kohn-Sham eigenvalues. The advantage of using PEpSI is that it has a much lower computational complexity than that associated with the matrix diagonalization procedure. We demonstrate the performance gain by comparing the timing of PEpSI with that of diagonalization on insulating and metallic nanotubes. For these quasi-1D systems, the complexity of PEpSI is linear with respect to the number of atoms. This linear scaling can be observed in our computational experiments when the number of atoms in a nanotube is larger than a few hundreds. Both the wall clock time and the memory requirement of PEpSI is modest. This makes it even possible to perform Kohn-Sham DFT calculations for 10,000-atom nanotubes on a single processor. We also show that the use of PEpSI does not lead to loss of accuracy required in a practical DFT calculation.

  7. Transverse expansion of the electron sheath during laser acceleration of protons

    Science.gov (United States)

    Svensson, K.; Mackenroth, F.; Senje, L.; Gonoskov, A.; Harvey, C.; Aurand, B.; Hansson, M.; Higginson, A.; Dalui, M.; Lundh, O.; McKenna, P.; Persson, A.; Marklund, M.; Wahlström, C.-G.

    2017-12-01

    The transverse expansion of the electrostatic sheath during target normal sheath acceleration of protons is investigated experimentally using a setup with two synchronized laser pulses. With the pulses spatially separated by less than three laser spot diameters, the resulting proton beam profiles become elliptical. By introducing a small intensity difference between the two pulses, the ellipses are rotated by a certain angle, except if the spatial separation of the two laser pulses is in the plane of incidence. The rotation angle is shown to depend on the relative intensity of the two pulses. The observed effects are found to require high temporal contrasts of the laser pulses. A simple model describing how the transverse shape of the electron sheath on the rear of the target depends on the relative intensity between the foci is presented. The model assumptions are verified, and the unknown dependence of the transverse extents of the sheaths are estimated self-consistently through a series of high resolution, two-dimensional particle-in-cell simulations. The results predicted by the model are also shown to be consistent with those obtained from the experiment.

  8. Magnetotransport of hot electrons and holes in the spin-valve transistor

    NARCIS (Netherlands)

    Gökcan, H.

    The conventional electronics uses the charge property of the electrons and holes. The building blocks are semiconductors which can be tuned to change the properties of the devices. In the field of spintronics, the spin property of the charge carriers is added to the functionality of the devices. The

  9. Valve Disease

    Science.gov (United States)

    ... See also on this site: Diseases of the Mitral Valve Diseases of the Aortic Valve Diseases of the Tricuspid ... most invasive option for the treatment of valve disease. During surgery, ... defects of the mitral valve. Replacement is used to treat any diseased ...

  10. Is spin transport through molecules really occurring in organic spin valves? A combined magnetoresistance and inelastic electron tunnelling spectroscopy study

    Science.gov (United States)

    Galbiati, Marta; Tatay, Sergio; Delprat, Sophie; Khanh, Hung Le; Servet, Bernard; Deranlot, Cyrile; Collin, Sophie; Seneor, Pierre; Mattana, Richard; Petroff, Frédéric

    2015-02-01

    Molecular and organic spintronics is an emerging research field which combines the versatility of chemistry with the non-volatility of spintronics. Organic materials have already proved their potential as tunnel barriers (TBs) or spacers in spintronics devices showing sizable spin valve like magnetoresistance effects. In the last years, a large effort has been focused on the optimization of these organic spintronics devices. Insertion of a thin inorganic tunnel barrier (Al2O3 or MgO) at the bottom ferromagnetic metal (FM)/organic interface seems to improve the spin transport efficiency. However, during the top FM electrode deposition, metal atoms are prone to diffuse through the organic layer and potentially short-circuit it. This may lead to the formation of a working but undesired FM/TB/FM magnetic tunnel junction where the organic plays no role. Indeed, establishing a protocol to demonstrate the effective spin dependent transport through the organic layer remains a key issue. Here, we focus on Co/Al2O3/Alq3/Co junctions and show that combining magnetoresistance and inelastic electron tunnelling spectroscopy measurements one can sort out working "organic" and short-circuited junctions fabricated on the same wafer.

  11. Is spin transport through molecules really occurring in organic spin valves? A combined magnetoresistance and inelastic electron tunnelling spectroscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Galbiati, Marta; Tatay, Sergio; Delprat, Sophie; Khanh, Hung Le; Deranlot, Cyrile; Collin, Sophie; Seneor, Pierre, E-mail: pierre.seneor@thalesgroup.com; Mattana, Richard, E-mail: richard.mattana@thalesgroup.com; Petroff, Frédéric [Unité Mixte de Physique CNRS/Thales, 1 Av. A. Fresnel, 91767 Palaiseau, France and Université Paris-Sud, 91405 Orsay (France); Servet, Bernard [Thales Research and Technology, 1 Av. A. Fresnel, 91767 Palaiseau (France)

    2015-02-23

    Molecular and organic spintronics is an emerging research field which combines the versatility of chemistry with the non-volatility of spintronics. Organic materials have already proved their potential as tunnel barriers (TBs) or spacers in spintronics devices showing sizable spin valve like magnetoresistance effects. In the last years, a large effort has been focused on the optimization of these organic spintronics devices. Insertion of a thin inorganic tunnel barrier (Al{sub 2}O{sub 3} or MgO) at the bottom ferromagnetic metal (FM)/organic interface seems to improve the spin transport efficiency. However, during the top FM electrode deposition, metal atoms are prone to diffuse through the organic layer and potentially short-circuit it. This may lead to the formation of a working but undesired FM/TB/FM magnetic tunnel junction where the organic plays no role. Indeed, establishing a protocol to demonstrate the effective spin dependent transport through the organic layer remains a key issue. Here, we focus on Co/Al{sub 2}O{sub 3}/Alq{sub 3}/Co junctions and show that combining magnetoresistance and inelastic electron tunnelling spectroscopy measurements one can sort out working “organic” and short-circuited junctions fabricated on the same wafer.

  12. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  13. Heart valve surgery

    Science.gov (United States)

    Valve replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... can relieve your symptoms and prolong your life. Mechanical heart valves do not often fail. However, blood clots can ...

  14. On the calculation of electron atom collision processes using exterior complex dilated S-matrix expansions

    Energy Technology Data Exchange (ETDEWEB)

    Carlsund, C. (Manne Siegbahn Inst. of Physics, Stockholm (Sweden) Dept. of Theoretical Physics, Royal Inst. of Tech., Stockholm (Sweden)); Krylstedt, P. (Manne Siegbahn Inst. of Physics, Stockholm (Sweden) Dept. of Theoretical Physics, Royal Inst. of Tech., Stockholm (Sweden) Swedish National Defence Establishment, Stockholm (Sweden)); Elander, N. (Manne Siegbahn Inst. of Physics, Stockholm (Sweden)); Cowan, R.D. (Los Alamos National Lab., NM (USA))

    1990-09-01

    Our work on analytically continued scattering theory based on the Schroedinger equation is reviewed. We give a brief description of how resonances, here defined as partial wave S-matrix poles, can be calculated as complex eigenvalues to the complex scaled Schroedinger equation. A Mittag-Leffler type expansion is then introduced and it is shown how one can partition a scattering cross section into contributions from isolated S-matrix poles and a background. Computationally this method has proven to be considerably faster than conventional methods. A new, faster and more accurate integration method is used. Examples of detailed previous work as well as current research are given. (orig.).

  15. The spin-valve transistor

    NARCIS (Netherlands)

    Anil Kumar, P.S.; Lodder, J.C.

    2000-01-01

    The spin-valve transistor is a magnetoelectronic device that can be used as a magnetic field sensor. It has a ferromagnet-semiconductor hybrid structure. Using a vacuum metal bonding technique, the spin-valve transistor structure Si/Pt/NiFe/Au/Co/Au/Si is obtained. It employs hot electron transport

  16. Confronting electron-positron annihilation into hadrons with QCD: an operator product expansion analysis

    Science.gov (United States)

    Bodenstein, S.; Dominguez, C. A.; Eidelman, S. I.; Spiesberger, H.; Schilcher, K.

    2012-01-01

    Experimental data on the total cross section of e + e - annihilation into hadrons are confronted with QCD and the operator product expansion using finite energy sum rules. Specifically, the power corrections in the operator product expansion, i.e. the vacuum condensates, of dimension d = 2, 4 and 6 are determined using recent isospin I = 0 + {1} data sets. Reasonably stable results are obtained which are compatible within errors with values from τ -decay. However, the rather large data uncertainties, together with the current value of the strong coupling constant, lead to very large errors in the condensates. It also appears that the separation into isovector and isoscalar pieces introduces additional uncertainties and errors. In contrast, the high precision τ -decay data of the ALEPH collaboration in the vector channel allows for a more precise determination of the condensates. This is in spite of QCD asymptotics not quite been reached at the end of the τ spectrum. We point out that isospin violation is negligible in the integrated cross sections, unlike the case of individual channels.

  17. Path-decomposition expansion and edge effects in a magnetized electron gas

    NARCIS (Netherlands)

    Suttorp, L.G.

    2000-01-01

    The influence of boundaries on the properties of a magnetized free-electron gas is discussed with the help of a path-integral representation for the temperature Green function. By using a suitable decomposition of the paths the profiles of the excess particle density and the current density are

  18. Pregnancy-induced remodeling of heart valves.

    Science.gov (United States)

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves. Copyright © 2015 the American Physiological Society.

  19. Electron cooling and finite potential drop in a magnetized plasma expansion

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Sanchez, M. [Department of Aeronautics and Astronautics, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139 (United States); Navarro-Cavallé, J. [Escuela Técnica Superior de Ingeniería Aeronáutica y del Espacio, Universidad Politécnica de Madrid, Plaza Cardenal Cisneros 3, Madrid 28040 (Spain); Ahedo, E. [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Avda. Universidad 30, Leganés 28911, Madrid (Spain)

    2015-05-15

    The steady, collisionless, slender flow of a magnetized plasma into a surrounding vacuum is considered. The ion component is modeled as mono-energetic, while electrons are assumed Maxwellian upstream. The magnetic field has a convergent-divergent geometry, and attention is restricted to its paraxial region, so that 2D and drift effects are ignored. By using the conservation of energy and magnetic moment of particles and the quasi-neutrality condition, the ambipolar electric field and the distribution functions of both species are calculated self-consistently, paying attention to the existence of effective potential barriers associated to magnetic mirroring. The solution is used to find the total potential drop for a set of upstream conditions, plus the axial evolution of various moments of interest (density, temperatures, and heat fluxes). The results illuminate the behavior of magnetic nozzles, plasma jets, and other configurations of interest, showing, in particular, in the divergent plasma the collisionless cooling of electrons, and the generation of collisionless electron heat fluxes.

  20. The evolution of magnetic transitions, negative thermal expansion and unusual electronic transport properties in Mn3AgxMnyN

    Science.gov (United States)

    Deng, Sihao; Sun, Ying; Yan, Jun; Shi, Zaixing; Shi, Kewen; Wang, Lei; Hu, Pengwei; Malik, Muhammad Imran; Wang, Cong

    2015-11-01

    The antiperovskite compounds Mn3AgxMnyN with Ag vacancies and Mn doping at Ag site were synthesized and investigated. The introduction of Ag vacancies has a very small influence on magnetic transitions. However, the magnetic transitions at TN (Néel temperature) and Tt (transition at lower temperature) gradually overlap with Mn doping accompanied by broadening of negative thermal expansion behavior. We also observed the nearly zero temperature coefficient of resistivity (NZ-TCR) behavior above magnetic order-disorder transition. The tunable TCR values from positive to negative could be achieved in Mn3AgxMnyN by reducing the contribution of (electron-phonon) e-p scattering in resistivity. Our results reveal the significance of e-p scattering for the evolution of TCR values, which could enrich the understanding of NZ-TCR behavior in antiperovskite manganese nitrides.

  1. Cryo-electron microscopy and single molecule fluorescent microscopy detect CD4 receptor induced HIV size expansion prior to cell entry

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Son [Deakin University, Victoria 3216 (Australia); CSIRO Australian Animal Health Laboratory, Victoria 3220 (Australia); Tabarin, Thibault [ARC Centre of Excellence in Advanced Molecular Imaging, University of New South Wales, New South Wales 3220 (Australia); Garvey, Megan; Pade, Corinna [Deakin University, Victoria 3216 (Australia); CSIRO Australian Animal Health Laboratory, Victoria 3220 (Australia); Rossy, Jérémie [ARC Centre of Excellence in Advanced Molecular Imaging, University of New South Wales, New South Wales 3220 (Australia); Monaghan, Paul; Hyatt, Alex [CSIRO Australian Animal Health Laboratory, Victoria 3220 (Australia); Böcking, Till [ARC Centre of Excellence in Advanced Molecular Imaging, University of New South Wales, New South Wales 3220 (Australia); Leis, Andrew [CSIRO Australian Animal Health Laboratory, Victoria 3220 (Australia); Gaus, Katharina, E-mail: k.gaus@unsw.edu.au [ARC Centre of Excellence in Advanced Molecular Imaging, University of New South Wales, New South Wales 3220 (Australia); Mak, Johnson, E-mail: j.mak@deakin.edu.au [Deakin University, Victoria 3216 (Australia); CSIRO Australian Animal Health Laboratory, Victoria 3220 (Australia)

    2015-12-15

    Viruses are often thought to have static structure, and they only remodel after the viruses have entered target cells. Here, we detected a size expansion of virus particles prior to viral entry using cryo-electron microscopy (cryo-EM) and single molecule fluorescence imaging. HIV expanded both under cell-free conditions with soluble receptor CD4 (sCD4) targeting the CD4 binding site on the HIV-1 envelope protein (Env) and when HIV binds to receptor on cellular membrane. We have shown that the HIV Env is needed to facilitate receptor induced virus size expansions, showing that the ‘lynchpin’ for size expansion is highly specific. We demonstrate that the size expansion required maturation of HIV and an internal capsid core with wild type stability, suggesting that different HIV compartments are linked and are involved in remodelling. Our work reveals a previously unknown event in HIV entry, and we propose that this pre-entry priming process enables HIV particles to facilitate the subsequent steps in infection. - Highlights: • Cell free viruses are able to receive external trigger that leads to apparent size expansion. • Virus envelope and CD4 receptor engagement is the lynchpin of virus size expansion. • Internal capsid organisation can influence receptor mediated virus size expansion. • Pre-existing virus-associated lipid membrane in cell free virus can accommodate the receptor mediated virus size expansion.

  2. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  3. Manufacturable plastic microfluidic valves using thermal actuation.

    Science.gov (United States)

    Pitchaimani, Karthik; Sapp, Brian C; Winter, Adam; Gispanski, Austin; Nishida, Toshikazu; Hugh Fan, Z

    2009-11-07

    A low-cost, manufacturable, thermally actuated, plastic microfluidic valve has been developed. The valve contains an encapsulated, temperature-sensitive fluid, which expands, deflecting a thin elastomeric film into a fluidic channel to control fluid flow. The power input for thermal expansion of each microfluidic valve can be controlled using a printed circuit board (PCB)-based controller, which is suitable for mass production and large-scale integration. A plastic microfluidic device with such valves was fabricated using compression molding and thermal lamination. The operation of the valves was investigated by measuring a change in the microchannel's ionic conduction current mediated by the resistance variation corresponding to the deflection of the microvalve. Valve closing was also confirmed by the disappearance of fluorescence when a fluorescent solution was displaced in the valve region. Valve operation was characterized for heater power ranging from 36 mW to 80 mW. When the valve was actuating, the local channel temperature was 10 to 19 degrees C above the ambient temperature depending on the heater power used. Repetitive valve operations (up to 50 times) have been demonstrated with a flow resulting from a hydrostatic head. Valve operation was tested for a flow rate of 0.33-4.7 microL/min.

  4. On the error in the nucleus-centered multipolar expansion of molecular electron density and its topology: A direct-space computational study

    Science.gov (United States)

    Michael, J. Robert; Koritsanszky, Tibor

    2017-05-01

    The convergence of nucleus-centered multipolar expansion of the quantum-chemical electron density (QC-ED), gradient, and Laplacian is investigated in terms of numerical radial functions derived by projecting stockholder atoms onto real spherical harmonics at each center. The partial sums of this exact one-center expansion are compared with the corresponding Hansen-Coppens pseudoatom (HC-PA) formalism [Hansen, N. K. and Coppens, P., "Testing aspherical atom refinements on small-molecule data sets," Acta Crystallogr., Sect. A 34, 909-921 (1978)] commonly utilized in experimental electron density studies. It is found that the latter model, due to its inadequate radial part, lacks pointwise convergence and fails to reproduce the local topology of the target QC-ED even at a high-order expansion. The significance of the quantitative agreement often found between HC-PA-based (quadrupolar-level) experimental and extended-basis QC-EDs can thus be challenged.

  5. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  6. Phase diagram of electronic systems with quadratic Fermi nodes in 2 expansion, 4 -ɛ expansion, and functional renormalization group

    Science.gov (United States)

    Janssen, Lukas; Herbut, Igor F.

    2017-02-01

    Several materials in the regime of strong spin-orbit interaction such as HgTe, the pyrochlore iridate Pr2Ir2O7 , and the half-Heusler compound LaPtBi, as well as various systems related to these three prototype materials, are believed to host a quadratic band touching point at the Fermi level. Recently, it has been proposed that such a three-dimensional gapless state is unstable to a Mott-insulating ground state at low temperatures when the number of band touching points N at the Fermi level is smaller than a certain critical number Nc. We further substantiate and quantify this scenario by various approaches. Using ɛ expansion near two spatial dimensions, we show that Nc=64 /(25 ɛ2) +O (1 /ɛ ) and demonstrate that the instability for N expansion both near two as well as near four dimensions, and which smoothly interpolates between these two perturbatively accessible limits for general 2

  7. Maxillary Expansion

    OpenAIRE

    Agarwal, Anirudh; Mathur, Rinku

    2010-01-01

    ABSTRACT Maxillary transverse discrepancy usually requires expansion of the palate by a combination of orthopedic and orthodontic tooth movements. Three expansion treatment modalities are used today: rapid maxillary expansion, slow maxillary expansion and surgically assisted maxillary expansion.This article aims to review the maxillary expansion by all the three modalities and a brief on commonly used appliances.

  8. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  9. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  10. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  11. Butterfly valve. Spjeldventil

    Energy Technology Data Exchange (ETDEWEB)

    Cupedo, D.J.

    1984-02-06

    Butterfly valve comprising a body and a valve seat arranged therein, on which a valve member is supported. The valve member comprises an operating rod and the assembly of valve member and operating rod has a fixed pivot point at the bottom of the body. The operating rod can be moved by means of pins movable in grooves and slots in such a manner that when the valve is opened the valve member first pivots about the pivot point to lift the valve member from the seat and subsequently rotates about the pivot point to fully open the valve. 12 drawings.

  12. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  13. Aortic Valve Stenosis

    Science.gov (United States)

    ... rapid, fluttering heartbeat Not eating enough (mainly in children with aortic valve stenosis) Not gaining enough weight (mainly in children with aortic valve stenosis) The heart-weakening effects of aortic valve stenosis ...

  14. Cryo-electron microscopy and single molecule fluorescent microscopy detect CD4 receptor induced HIV size expansion prior to cell entry.

    Science.gov (United States)

    Pham, Son; Tabarin, Thibault; Garvey, Megan; Pade, Corinna; Rossy, Jérémie; Monaghan, Paul; Hyatt, Alex; Böcking, Till; Leis, Andrew; Gaus, Katharina; Mak, Johnson

    2015-12-01

    Viruses are often thought to have static structure, and they only remodel after the viruses have entered target cells. Here, we detected a size expansion of virus particles prior to viral entry using cryo-electron microscopy (cryo-EM) and single molecule fluorescence imaging. HIV expanded both under cell-free conditions with soluble receptor CD4 (sCD4) targeting the CD4 binding site on the HIV-1 envelope protein (Env) and when HIV binds to receptor on cellular membrane. We have shown that the HIV Env is needed to facilitate receptor induced virus size expansions, showing that the 'lynchpin' for size expansion is highly specific. We demonstrate that the size expansion required maturation of HIV and an internal capsid core with wild type stability, suggesting that different HIV compartments are linked and are involved in remodelling. Our work reveals a previously unknown event in HIV entry, and we propose that this pre-entry priming process enables HIV particles to facilitate the subsequent steps in infection. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. What Is Heart Valve Disease?

    Science.gov (United States)

    ... Heart Valves Sometimes heart valves can’t be repaired and must be replaced. This surgery involves removing the faulty valve and replacing it with a man-made or biological valve. Biological valves are made ...

  16. Morphological assessment of sucrose preservation for porcine heart valves.

    OpenAIRE

    Drury, P J; Olsen, E G; Ross, D N

    1982-01-01

    Porcine aortic valves stored in various concentrations of sucrose (50-80%) for up to 52 weeks were examined both histologically and by electron microscopy. The valves were compared with porcine aortic valves stored in a nutrient and antibiotic medium for 12 weeks. Overall preservation was better in those porcine valves stored in sucrose solution than in nutrient and antibiotic medium, the best preservation being in 50% sucrose. Despite wide separation of collagen at that concentration seen on...

  17. Defect structure, electronic conductivity and expansion of properties of (La1−xSrx)sCo1−yNiyO3−δ

    DEFF Research Database (Denmark)

    Hjalmarsson, Per; Søgaard, Martin; Mogensen, Mogens Bjerg

    2010-01-01

    This study reports on oxygen nonstoichiometry, electronic conductivity and lattice expansion of three compositions as function of T and PO2 in the (La1−xSrx)sCo1−yNiyO3−δ (x=0.1, y=0.4; x=0.1, y=0.3; x=0.2, y=0.2) materials system. The nonstoichiometry data were successfully fitted using the itin......This study reports on oxygen nonstoichiometry, electronic conductivity and lattice expansion of three compositions as function of T and PO2 in the (La1−xSrx)sCo1−yNiyO3−δ (x=0.1, y=0.4; x=0.1, y=0.3; x=0.2, y=0.2) materials system. The nonstoichiometry data were successfully fitted using...... the itinerant electron model which indicates the existence of delocalized electronic states. This was also reflected in the high electronic conductivities, above 1000 S cm−1, measured for all three compositions. The electronic conductivity was shown to decrease linearly with the oxygen nonstoichiometry...... parameter, δ, supporting that the conductivity is dependent on p-type charge carriers. Comparing calculated p-type mobilities with data reported in literature on La1−xSrxCoO3 indicated that Ni-substitution into (La1−xSrx)sCoO3−δ increases the p-type mobility. The electronic conductivity was also found...

  18. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  19. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  20. Mitral valve regurgitation

    Science.gov (United States)

    ... around the valve. You are at risk for mitral valve regurgitation if you have: Coronary heart disease and high blood pressure Infection of the heart valves Mitral valve prolapse (MVP) Rare conditions, such as untreated syphilis or Marfan ... heart disease. This is a complication of untreated strep throat ...

  1. Tissue engineered aortic valve

    OpenAIRE

    Dohmen, P M

    2012-01-01

    Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation heart valve, which overcome limitations of biological and mechanical heart valves due to remodelling,...

  2. Comparison of Conjugate Gradient Density Matrix Search and Chebyshev Expansion Methods for Avoiding Diagonalization in Large-Scale Electronic Structure Calculations

    Science.gov (United States)

    Bates, Kevin R.; Daniels, Andrew D.; Scuseria, Gustavo E.

    1998-01-01

    We report a comparison of two linear-scaling methods which avoid the diagonalization bottleneck of traditional electronic structure algorithms. The Chebyshev expansion method (CEM) is implemented for carbon tight-binding calculations of large systems and its memory and timing requirements compared to those of our previously implemented conjugate gradient density matrix search (CG-DMS). Benchmark calculations are carried out on icosahedral fullerenes from C60 to C8640 and the linear scaling memory and CPU requirements of the CEM demonstrated. We show that the CPU requisites of the CEM and CG-DMS are similar for calculations with comparable accuracy.

  3. Electronic Waste: DOD Is Recovering Materials, but Several Factors May Hinder Near-Term Expansion of These Efforts

    Science.gov (United States)

    2016-06-01

    conclusions based on our audit objectives. The Strategic and Critical Materials Stock Piling Act provides for the acquisition and retention of... Strategy for Electronic Stewardship, July 20, 2011. The federal government website on electronics stewardship references this guidance in the context...and other federal agency customers pay to obtain these recovered precious metals are below current market prices; customers are charged only for the

  4. Risks for Heart Valve Problems

    Science.gov (United States)

    ... Thromboembolism Aortic Aneurysm More Risks for Heart Valve Problems Updated:Jan 18,2017 Who is at risk ... content was last reviewed May 2016. Heart Valve Problems and Disease • Home • About Heart Valves • Heart Valve ...

  5. Living with Heart Valve Disease

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  6. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  7. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  8. Superluminal sheath-field expansion and fast-electron-beam divergence measurements in laser-solid interactions.

    Science.gov (United States)

    Ridgers, C P; Sherlock, M; Evans, R G; Robinson, A P L; Kingham, R J

    2011-03-01

    We show that including a sufficient description of the target's rear surface significantly affects the interpretation of a wide range of laser-solid experiments. A simple Debye sheath model will be shown to be adequate. From this the sheath field responsible for ion acceleration has been shown to expand at superluminal speeds, leading to very large ion-emission regions on the target's rear surface; a new explanation for the dynamics of the ion-accelerating sheath field accounts for this observation and demonstrates the inaccuracy of measuring the angular divergence of the injected electron beam, crucial to fast ignition, from the lateral extent of the ion emission. However, it is shown that on careful probing the sheath field can provide unique insight into details of the fast electron's distribution function. The relative merits of probing other physical quantities has been examined. The width of the background temperature spot overestimates the divergence by a factor of 2 unless electron recirculation is prevented.

  9. Mitral valve prolapse

    Science.gov (United States)

    ... mitral valve prolapse is called "mitral valve prolapse syndrome," and includes: Chest pain (not caused by coronary artery disease or a heart attack) Dizziness Fatigue Panic attacks Sensation of feeling the heart beat ( palpitations ) ...

  10. Mitral Valve Stenosis

    Science.gov (United States)

    ... valve stenosis include: Rheumatic fever. A complication of strep throat, rheumatic fever can damage the mitral valve. Rheumatic ... children see your doctor for sore throats. Untreated strep throat infections can develop into rheumatic fever. Fortunately, strep ...

  11. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  12. A case of SAPIEN XT valve fallen into left ventricle during valve-in-valve transcatheter aortic valve implantation.

    Science.gov (United States)

    Koizumi, Shigeki; Ehara, Natsuhiko; Nishiya, Kenta; Koyama, Tadaaki

    2017-06-24

    Late transcatheter heart valve embolization is a rare but life-threatening complication of transcatheter aortic valve implantation. Surgical intervention is performed for most cases, but some cases were treated by valve-in-valve transcatheter aortic valve implantation. We describe a patient in whom a 29-mm Edwards SAPIEN XT valve migrated into the left ventricular outflow tract 41 days after the initial implantation. We tried to perform valve-in-valve transcatheter aortic valve implantation using a transfemoral approach. As soon as the second transcatheter heart valve touched the first implanted valve, it fell into the left ventricle. Immediate surgical intervention was required. The first valve was removed, and surgical aortic valve replacement was successfully performed. In conclusion, we should choose surgical aortic valve replacement for late transcatheter heart valve embolization. Even if we need to treat by catheter intervention, transapical approach may be better.

  13. Blood compatibility of the jellyfish valve without anticoagulant.

    Science.gov (United States)

    Imachi, K; Mabuchi, K; Chinzei, T; Abe, Y; Imanishi, K; Suzukawa, M; Yonezawa, T; Kouno, A; Ono, T; Nozawa, H

    1991-01-01

    The blood compatibility of the jellyfish valve was studied. Artificial heart (AH) blood pumps incorporating jellyfish valves were connected to 18 goats as total artificial hearts (TAHs) and pumped for 1 to 125 days without anticoagulant or antiplatelet drugs. No thrombus was formed on the valve membrane or around the valve seat. Scanning electron microscopy showed almost no platelet deposition or microfibrin clot formation on the valve membrane, including its central region; the spokes of the valve seat were also free from platelet and microfibrin clots. No calcification was observed during these tests, and plasma free hemoglobin was between 2 and 7 mg/dl. The jellyfish valve revealed good blood compatibility, even without anticoagulant use.

  14. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  15. Post-focus expansion of ion beams for low fluence and large area MeV ion irradiation: Application to human brain tissue and electronics devices

    Science.gov (United States)

    Whitlow, Harry J.; Guibert, Edouard; Jeanneret, Patrick; Homsy, Alexandra; Roth, Joy; Krause, Sven; Roux, Adrien; Eggermann, Emmanuel; Stoppini, Luc

    2017-08-01

    Irradiation with ∼3 MeV proton fluences of 106-109 protons cm-2 have been applied to study the effects on human brain tissue corresponding to single-cell irradiation doses and doses received by electronic components in low-Earth orbit. The low fluence irradiations were carried out using a proton microbeam with the post-focus expansion of the beam; a method developed by the group of Breese [1]. It was found from electrophysiological measurements that the mean neuronal frequency of human brain tissue decreased to zero as the dose increased to 0-1050 Gy. Enhancement-mode MOSFET transistors exhibited a 10% reduction in threshold voltage for 2.7 MeV proton doses of 10 Gy while a NPN bipolar transistor required ∼800 Gy to reduce the hfe by 10%, which is consistent the expected values.

  16. Analytical solutions of the planar cyclic voltammetry process for two soluble species with equal diffusivities and fast electron transfer using the method of eigenfunction expansions

    Directory of Open Access Journals (Sweden)

    Adib Samin

    2015-08-01

    Full Text Available Cyclic voltammetry is a powerful tool that is used for characterizing electrochemical processes. Models of cyclic voltammetry take into account the mass transport of species and the kinetics at the electrode surface. Analytical solutions of these models are not well-known due to the complexity of the boundary conditions. In this study we present closed form analytical solutions of the planar voltammetry model for two soluble species with fast electron transfer and equal diffusivities using the eigenfunction expansion method. Our solution methodology does not incorporate Laplace transforms and yields good agreement with the numerical solution. This solution method can be extended to cases that are more general and may be useful for benchmarking purposes.

  17. Effects of High Temperature on the Microstructure of Automotive Engine Valves

    Directory of Open Access Journals (Sweden)

    Ajay Pandey

    2014-03-01

    Full Text Available In this paper, failures of automobile valves are considered and discussed. The changes in microstructures of valves were studied and analyzed with the aid of a Scanning Electron Microscope (SEM. Specimens were prepared out of failed engine valves whereas new valves were also analyzed for the sake of comparison. This was done by image analysis of specimens of failed and new valves at adequate magnification. The benchmarking of microstructures of failed valves v/s new valves revealed that the size of grains, grain boundaries, and distribution of carbide particles across the material matrix is affected by high temperature conditions and the effects are more severe for exhaust valves. The microstructure of valve material shows discernible changes after operating at high temperatures. The grain size of the material also changes at high temperature, thus resulting in a reduction in the hardness of the valve material which, in turn, causes more wear.

  18. Carbon Fiber Reinforced Carbon Composites Rotary Valves for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    Carbon fiber reinforced carbon composite rotary, sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or warp-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties, do not present the sealing and lubrication problems that have prevented rotary, sleeve, and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  19. Carbon Fiber Reinforced Carbon Composite Rotary Valve for an Internal Combustion Engine

    Science.gov (United States)

    Northam, G.Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    2000-01-01

    Carbon fiber reinforced carbon composite rotary sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or wrap-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties do not present the sealing and lubrication problems that have prevented rotary sleeve and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  20. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  1. Expansion of electronic health record-based screening, prevention, and management of diabetes in New York City.

    Science.gov (United States)

    Albu, Jeanine; Sohler, Nancy; Matti-Orozco, Brenda; Sill, Jordan; Baxter, Daniel; Burke, Gary; Young, Edwin

    2013-01-01

    To address the increasing burden of diabetes in New York City, we designed 2 electronic health records (EHRs)-facilitated diabetes management systems to be implemented in 6 primary care practices on the West Side of Manhattan, a standard system and an enhanced system. The standard system includes screening for diabetes. The enhanced system includes screening and ensures close patient follow-up; it applies principles of the chronic care model, including community-clinic linkages, to the management of patients newly diagnosed with diabetes and prediabetes through screening. We will stagger implementation of the enhanced system across the 6 clinics allowing comparison, through a quasi-experimental design (pre-post difference with a control group), of patients treated in the enhanced system with similar patients treated in the standard system. The findings could inform health system practices at multiple levels and influence the integration of community resources into routine diabetes care.

  2. Modeling study of the ABS relay valve

    Science.gov (United States)

    Lei, Ming; Lin, Min; Guo, Bin; Luo, Zai; Xu, Weidong

    2011-05-01

    The ABS (anti-lock braking system) relay valve is the key component of anti-lock braking system in most commercial vehicles such as trucks, tractor-trailers, etc. In this paper, structure of ABS relay valve and its work theory were analyzed. Then a mathematical model of ABS relay valve, which was investigated by dividing into electronic part, magnetic part, pneumatic part and mechanical part, was set up. The displacement of spools and the response of pressure increasing, holding, releasing of ABS relay valve were simulated and analyzed under conditions of control pressure 500 KPa, braking pressure 600 KPa, atmospheric pressure 100 KPa and air temperature 310 K. Thisarticle provides reliable theory for improving the performance and efficiency of anti-lock braking system of vehicles.

  3. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  4. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  5. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  6. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  7. Fusion of valve cushions as a key factor in the formation of congenital bicuspid aortic valves in Syrian hamsters.

    Science.gov (United States)

    Sans-Coma, V; Fernández, B; Durán, A C; Thiene, G; Arqué, J M; Muñoz-Chápuli, R; Cardo, M

    1996-04-01

    Bicuspid aortic valve is the most frequent congenital cardiac malformation in humans. However, the morphogenesis of the defect is still unknown. Previous work showed that, in the Syrian hamster, congenital bicuspid aortic valves with the aortic sinuses arranged in ventrodorsal orientation are expressions of a trait the variation of which takes the form of a continuous phenotypic spectrum, ranging from a tricuspid aortic valve with no fusion of the ventral commissure to a bicuspid aortic valve devoid of any raphe. The present study was designed to elucidate the mechanism involved in the formation of bicuspid aortic valves in Syrian hamsters as a possible starting point for further investigation of this process in humans. The sample examined consisted of 80 embryos, aged between 10 days, 16 hours and 13 days, 1 hour postcoitum. Most (n = 59) of the embryos belonged to a laboratory-inbred family of Syrian hamsters with a high incidence of bicuspid aortic valves. The study was carried out using scanning electron microscopy and histological techniques for light microscopy. Twenty-three embryos showed a still undivided conotruncus. In all of these cases there were six mesenchymal semilunar valve primordia protruding into the lumen of the conotruncus. In a further 29 embryos, the conotruncus had just divided into the aortic and pulmonary channels; the embryos were at the beginning of the valvulogenesis. In 13 of these 29 embryos there were three well-defined aortic valve cushions, right, left, and dorsal, whereas in the other 16, the right and left valve cushions were more or less fused toward the lumen of the aorta; when they were completely fused, only two aortic valve cushions, a ventral and a dorsal, could be identified. In the remaining 28 embryos, the aortic valve cushions showed a marked degree of excavation. In 23 of these cases, the valve exhibited a basically tricuspid architecture, whereas it was unequivocally bicuspid in the other five. All variants of the

  8. An up-to-date overview of the most recent transcatheter implantable aortic valve prostheses

    NARCIS (Netherlands)

    Wiegerinck, Esther M. A.; van Kesteren, Floortje; van Mourik, Martijn S.; Vis, Marije M.; Baan, Jan

    2016-01-01

    Over the past decade transcatheter aortic valve implantation (TAVI) has evolved towards the routine therapy for high-risk patients with severe aortic valve stenosis. Technical refinements in TAVI are rapidly evolving with a simultaneous expansion of the number of available devices. This review will

  9. Replaceable valve seat

    Science.gov (United States)

    Jordan, Raymond W.

    1992-01-01

    A valve with an O-ring, a disk seal, and a replaceable valve seat is presented. A groove in the bottom on the valve seat flange forms an inner and outer drip ledge with the inner and outer periphery of the flange. If leakage occurs at the valve seat O-ring, fluid droplets will form on the out drip ledge. If leakage occurs at the disk seal, fluid droplets will form on the inner drip ledge. A visual inspection of these drip ledges through an access port, or by a borescope placed in an inspection port, can discriminate between a leak which originates in the O-ring and a leak which originates in the disk seal. When conventional replaceable valve seats leak, fluid droplets form at the bottom on the valve seat. In the present invention, such a valve seat is modified by machining a groove on the bottom surface of the valve seat flange. This groove and the inner and outer surfaces of the flange intersect and form drip ledges. If leakage occurs at the valve seat seal, shown as an O-ring in the preferred embodiment, fluid droplets will form on the outer drip ledge. If leakage occurs at the valve disk seal, fluid droplets will form on the inner drip ledge. The drip ledges can be inspected either through an access port or by passing a borescope through a small inspection port in the valve case. Visual inspection of the bottom on the drip ledge will positively identify the required repair action.

  10. Valve reconstruction for congenital mitral valve disease.

    Science.gov (United States)

    Quinonez, Luis G; Del Nido, Pedro J

    2015-01-01

    The surgical treatment of mitral valve disease in children is a challenging problem. Mitral stenosis and regurgitation may occur in isolation or together. Mitral valve repair is almost always preferable to replacement. Mitral valve replacement is not an ideal alternative to repair due to limitations of size, growth, structural valve degeneration, anticoagulation and poor survival. Surgical repair of congenital mitral stenosis must address the multiple levels of obstruction, including resection of the supramitral ring, thinning of leaflets and mobilization of the subvalvular apparatus. Sometimes leaflet augmentation is required. Repair of mitral regurgitation in children may involve simple cleft closures, edge-to-edge repairs, triangular resections and annuloplasties. Techniques used in adults, such as annuloplasty bands or artificial chords, may not be appropriate for children. Overall, an imperfect mitral valve repair may be more acceptable than the negative consequences of a replacement in a child. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. expansion method

    Indian Academy of Sciences (India)

    In this paper, we shall apply the (G /G)-expansion method to obtain the exact travelling wave solution of the two-dimensional ... In §3, we apply our method to the mentioned equations. In §4, some conclusions are ..... The exact solution obtained by this method can be used to check computer codes or as initial condition for ...

  12. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  13. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  14. Mitral Valve Prolapse

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ...

  15. Mitral Valve Disease

    Science.gov (United States)

    ... clots, but they also are less durable than mechanical valves and may need to be replaced in the future. Like mitral valve repair, replacement can be done minimally invasively or with traditional open heart surgery. Your medical team will discuss the advantages ...

  16. Electromechanically Actuated Valve for Controlling Flow Rate

    Science.gov (United States)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  17. Transcatheter aortic valve implantation for bicuspid aortic valve stenosis.

    Science.gov (United States)

    Hamdan, Ashraf; Kornowski, Ran

    2015-08-01

    In Preprocedural CT, patients with BAV have larger aortic annulus perimeters, and more calcified valves compared with TAV. In patients with BAV, self-expandable valves were under-expand and balloon-expandable valves have a trend toward increased rates of postimplantation AR grade. Self-expandable valves have higher postprocedural gradient in BAV compared with TAV. © 2015 Wiley Periodicals, Inc.

  18. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  19. [Related research on mechanical property of valve membrane in transcatheter bioprosthesis valve based on the chemical modification and cutting technology].

    Science.gov (United States)

    Chen, Dakai; Li, Yu; Luo, Qiyi; Liu, Baolin; Chen, Kangmin

    2014-08-01

    The aim of this research is to investigate the preparation method of valve membrane in transcatheter bio- prosthetic valve, and to study the effect of chemical modification and cutting technology to tensile property and suture force property of valve membrane. We carried out a series of processes to perform the tests, such as firstly to test the crosslinking degree of valve membrane using ninhydrin method, then to test the tensile property and suture force property by using Instron's biomechanicAl testing equipment, and then to observe the collagen fiber orientation in valve membrane using Instron's biomechanical testing equipment and using field emission scanning electron microscopy. The study indicated that after the chemical modification, the crosslinking degree, tensile strength and suture force strength increasing rate of valve membrane were 93.78% ± 3. 2%, (8.24 ± 0.79) MPa, 102%, respectively. The valve membrane had a better biomechanical property and would be expected to become valve membrane in transcatheter bioprosthesis valve.

  20. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  1. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    OpenAIRE

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mecha...

  2. Mitral valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... stroke. Valves made from human or animal tissue fail over time. They have an average lifespan of ...

  3. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  4. Aortic Valve Regurgitation

    Science.gov (United States)

    ... valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a common childhood illness in the ... a severe sore throat, see a doctor. Untreated strep throat can lead to rheumatic fever. Fortunately, strep throat ...

  5. Hydrodynamic characterization of a passive shape memory alloy valve

    Science.gov (United States)

    Waddell, A. M.; Punch, J.; Stafford, J.; Jeffers, N.

    2014-07-01

    Next generation high-performance electronics will have large heat fluxes (>102 W/cm2) and an alternative approach to traditional air cooling is required. An attractive solution is micro-channel cooling and micro-valves will be required for refined flow control in the supporting micro-fluidic systems. A NiTi Shape Memory Alloy (SMA) micro-valve design was hydrodynamically characterized in this work to obtain the valve loss coefficient (K) from pressure measurements. The hydrodynamic characterization was important as in the flow regime of the micro-fluidic system K is sensitive to Reynolds number (Re) and geometry. Static replicas of the SMA valve geometry were studied for low Reynolds numbers (110 - 220) in a 1x1 mm CSA miniature channel. The loss coefficients were found to be sensitive to flow rate and decreased rapidly with an increase in Re. The SMA valve was compared to a similar gate micro-valve and loss across both valves was of the same order of magnitude. The valve loss coefficients obtained in this work are important parameters in the modeling and design of micro-fluidic cooling systems.

  6. How Is Heart Valve Disease Treated?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  7. How Is Heart Valve Disease Diagnosed?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  8. When a Heart Murmur Signals Valve Disease

    Science.gov (United States)

    ... Order AHA Brochures Your Heart Valve Surgery Your Mitral Valve Prolapse Innocent Heart Murmurs If Your Child Has a Congenital Heart Defect See all of our brochures Valve Disease Resources Patient Guide: Understanding Your Heart Valve Problem | ...

  9. Low-field magnetocurrent above 200% in a spin-valve transistor at room temperature

    NARCIS (Netherlands)

    Anil Kumar, P.S.; Jansen, R.; van 't Erve, O.M.J.; Vlutters, R.; de Haan, P.; Lodder, J.C.

    2000-01-01

    A spin-valve transistor (SVT) that employs hot electrons is shown to exhibit a huge magnetotransport effect at room temperature in small magnetic fields. The SVT is a ferromagnet-semiconductor hybrid structure in which hot electrons are injected into a NiFe/Au/Co spin valve, and collected on the

  10. First in human implantation of the mechanical expanding Lotus® valve in degenerated surgical valves in mitral position.

    Science.gov (United States)

    Schaefer, Ulrich; Conradi, Lenard; Lubos, Edith; Deuschl, Florian; Schofer, Niklas; Seiffert, Moritz; Treede, Hendrik; Schirmer, Johannes; Reichenspurner, Hermann; Blankenberg, Stefan

    2015-12-01

    Implantation of transcatheter heart valves (THV) into degenerated surgical valves is an emerging therapy for selected high-risk patients. Although, CE mark of most THV is limited for native aortic valvular stenosis, transcatheter valve implantation into degenerated bioprostheses, even in mitral position is very intriguing. After placement of a cerebral protection device (Claret Sentinel®), three consecutive patients (age, 79.0 ± 6.1; log EuroSCORE I: 33.3 ± 9.2%) with a degenerated mitral bioprosthesis were treated by transapical implantation of the Lotus® valve (Boston Scientific Inc.). In addition, a SwanGanz catheter was introduced in the pulmonary artery for hemodynamic assessments all patients. Procedural success was 100%. Valve implantation was performed without rapid ventricular pacing. Resheating was performed in two patients due to suboptimal initial positioning. Invasive online hemodynamics revealed stable blood pressure in all patients. After Lotus® valve implantation, valvular mitral regurgitation was completely eliminated in all patients. One patient had a mild paravalvular leak of the surgical bioprosthesis, which was present before implantation. Invasive right and left heart hemodynamics showed an immediate improvement after Lotus® valve implantation. Mean mitral surface area (2.1 ± 0.2 cm(2) ) and mean gradient (3.7 ± 2.1 mm Hg) demonstrated satisfactory results. All patients were immediately extubated and discharged from the hospital without any adverse event. This study demonstrates for the first time the feasibility of transapical Lotus® Valve implantation in degenerated mitral bioprostheses. The controlled mechanical Lotus® valve expansion with remarkably stable hemodynamics throughout the procedure offers a new and valuable treatment option. © 2015 Wiley Periodicals, Inc.

  11. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  12. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  13. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... diseases of the tricuspid valve are regurgitation and stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid ... the tricuspid valve may also be needed. Tricuspid Stenosis Tricuspid stenosis is a narrowing or blockage of ...

  14. Options for Heart Valve Replacement

    Science.gov (United States)

    ... valve: Aortic regurgitation , (sometimes referred to as aortic insufficiency) is another common valve problem that may require ... allows oxygenated blood to flow backwards into the lungs instead of continuing through the heart as it ...

  15. Variable Valve Actuation

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    Many approaches exist to enable advanced mode, low temperature combustion systems for diesel engines - such as premixed charge compression ignition (PCCI), Homogeneous Charge Compression Ignition (HCCI) or other HCCI-like combustion modes. The fuel properties and the quantity, distribution and temperature profile of air, fuel and residual fraction in the cylinder can have a marked effect on the heat release rate and combustion phasing. Figure 1 shows that a systems approach is required for HCCI-like combustion. While the exact requirements remain unclear (and will vary depending on fuel, engine size and application), some form of substantially variable valve actuation is a likely element in such a system. Variable valve actuation, for both intake and exhaust valve events, is a potent tool for controlling the parameters that are critical to HCCI-like combustion and expanding its operational range. Additionally, VVA can be used to optimize the combustion process as well as exhaust temperatures and impact the after treatment system requirements and its associated cost. Delphi Corporation has major manufacturing and product development and applied R&D expertise in the valve train area. Historical R&D experience includes the development of fully variable electro-hydraulic valve train on research engines as well as several generations of mechanical VVA for gasoline systems. This experience has enabled us to evaluate various implementations and determine the strengths and weaknesses of each. While a fully variable electro-hydraulic valve train system might be the 'ideal' solution technically for maximum flexibility in the timing and control of the valve events, its complexity, associated costs, and high power consumption make its implementation on low cost high volume applications unlikely. Conversely, a simple mechanical system might be a low cost solution but not deliver the flexibility required for HCCI operation. After modeling more than 200 variations of

  16. Echocardiography of the mitral valve

    OpenAIRE

    Omran, A.S.; Arifi, A.A.; Mohamed, A.A.

    2010-01-01

    Mitral valve disease is the second most common valvular heart disease after the aortic valve worldwide. Mitral valve has historically been a structure of interest by pioneers in echocardiography. One of the earliest applications of echocardiography was in the diagnosis of valvular heart disease, particularly mitral stenosis. In this review we wish to take the reader through the structural and hemodynamic evaluation of the normal mitral valve.

  17. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    Science.gov (United States)

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe

  18. Oil Stiction in Fast Switching Annular Seat Valves for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    Digital Displacement (DD) fluid power machines utilizes electronically controlled seat valves connected to pressure chambers to obtain variable displacement with high operational efficiency and high bandwidth. To achieve high efficiency, fast valve switching is essential and all aspects related...... to the dynamic behaviour of the seat valves must be considered to optimize the machine efficiency. A significant effect influencing the valves switching performance is the presence of oil stiction when separating the contact surfaces in valve opening movement. This oil stiction force is limited by cavitation...... for low pressure levels, e.g. valves connected to the low pressure manifold, however for valves operated at higher pressure levels, the oil stiction force is dominating when the separating surfaces are close to contact. This paper presents an analytic solution to the oil stiction force for annular seat...

  19. Development and multiplexed control of latching pneumatic valves using microfluidic logical structures.

    Science.gov (United States)

    Grover, William H; Ivester, Robin H C; Jensen, Erik C; Mathies, Richard A

    2006-05-01

    Novel latching microfluidic valve structures are developed, characterized, and controlled independently using an on-chip pneumatic demultiplexer. These structures are based on pneumatic monolithic membrane valves and depend upon their normally-closed nature. Latching valves consisting of both three- and four-valve circuits are demonstrated. Vacuum or pressure pulses as short as 120 ms are adequate to hold these latching valves open or closed for several minutes. In addition, an on-chip demultiplexer is demonstrated that requires only n pneumatic inputs to control 2(n-1) independent latching valves. These structures can reduce the size, power consumption, and cost of microfluidic analysis devices by decreasing the number of off-chip controllers. Since these valve assemblies can form the standard logic gates familiar in electronic circuit design, they should be useful in developing complex pneumatic circuits.

  20. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...

  1. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel.......It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...

  2. Edwards SAPIEN 3 valve.

    Science.gov (United States)

    Binder, Ronald K; Rodés-Cabau, Josep; Wood, David A; Webb, John G

    2012-09-01

    Building on the established success with the SAPIEN, SAPIEN XT and earlier prototypic transcatheter heart valves (THV) the newest balloon-expandable valve incorporates a number of new and enhanced features intended to reduce the risk of vascular injury, to reduce paravalvular regurgitation, and to facilitate rapid and accurate positioning and implantation. The SAPIEN 3 THV incorporates a cobalt chromium stent, bovine pericardial leaflets, and both an inner and new outer polyethylene terephthalate sealing cuff. The delivery system incorporates an active three-dimensional coaxial positioning catheter, and is compatible with a 14 Fr expandable sheath.

  3. Noncontacting valve-position indicator

    Science.gov (United States)

    Crovella, E. A.; Cummins, R. D.; Wada, J. M.

    1979-01-01

    Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

  4. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    Science.gov (United States)

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve.

    Science.gov (United States)

    Maymir, J C; Deutsch, S; Meyer, R S; Geselowitz, D B; Tarbell, J M

    1997-09-01

    While many investigators have measured the turbulent stresses associated with forward flow through tilting disk heart valves, only recently has attention been given to the regurgitant jets formed as fluid is squeezed through the gap between the occluder and housing of a closed valve. The objective of this investigation was to determine the effect of gap width on the turbulent stresses of the regurgitant jets through a Björk-Shiley monostrut tilting disk heart valve seated in the mitral position of a Penn State artificial heart. A 2 component laser-Doppler velocimetry system with a temporal resolution of 1 ms was used to measure the instantaneous velocities in the regurgitant jets in the major and minor orifices around the mitral valve. The gap width was controlled through temperature variation by taking advantage of the large difference between the thermal expansion coefficients of the Delrin occluder and the Stellite housing of Björk-Shiley monostrut valves. The turbulent shear stress and mean (ensemble averaged) velocity were incorporated into a model of red blood cell damage to assess the potential for hemolytic damage at each gap width investigated. The results revealed that the minor orifice tends to form stronger jets during regurgitant flow than the major orifice, indicating that the gap width is not uniform around the circumference of the valve. Based on the results of a red blood cell damage model, the hemolytic potential of the mitral valve decreases as the gap width increases. This investigation also established that the hemolytic potential of the regurgitant phase of valve operation is comparable to, if not greater than, the hemolytic potential of forward flow, consistent with experimental data on hemolysis.

  6. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  7. Aortic valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  8. The spin-valve transistor: a preview and outlook

    NARCIS (Netherlands)

    Jansen, R.

    2003-01-01

    Combining ferromagnetic and semiconductor materials is a challenging route to create new options for electronic devices in which the spin of the electron is employed. The spin-valve transistor (SVT) is the first of such hybrid devices shown to work successfully. This review describes the basic

  9. Rupture of mitral valve chordae in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Boissier, Florence; Achkouty, Guy; Bruneval, Patrick; Fabiani, Jean-Noël; Nguyen, Anh Tuan; Riant, Elisabeth; Desnos, Michel; Hagège, Albert

    2015-04-01

    While occasional reports of mitral valve chordal rupture have been described in hypertrophic cardiomyopathy, the exact prevalence and characteristics of this event in a large medical cohort have not been reported. To assess the prevalence of mitral valve chordal rupture in hypertrophic cardiomyopathy and the clinical, echocardiographic, surgical and histological profiles of those patients. We searched for patients with mitral valve chordal rupture diagnosed by echocardiography among all electronic files of patients admitted to our centre for hypertrophic cardiomyopathy between 2000 and 2010. Among 580 patients admitted for hypertrophic cardiomyopathy, six patients (1%, 5 men, age 68-71 years) presented with mitral valve chordal rupture, symptomatic in five cases, always involving the posterior mitral leaflet. In all cases, echocardiography before rupture showed mitral valve systolic anterior motion, with anterior (and not posterior) leaflet elongation compared with a random sample of patients with non-obstructive hypertrophic cardiomyopathy (P=0.006) (and similar to that observed in obstructive hypertrophic cardiomyopathy). Significant resting left ventricular outflow tract obstruction was always present before rupture and disappeared after rupture in the five cases requiring mitral valve surgery for severe mitral regurgitation. Histological findings were consistent with extensive myxomatous degeneration in all cases. Mitral valve chordal rupture is: infrequent in hypertrophic cardiomyopathy; occurs in aged patients with obstructive disease; involves, essentially, the posterior mitral leaflet; and causes, in general, severe mitral regurgitation requiring surgery. Myxomatous degeneration may be the substrate for rupture in these patients. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  11. Micro-valve pump light valve display

    Science.gov (United States)

    Lee, Yee-Chun

    1993-01-01

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  12. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  13. Digital valve for high pressure high flow applications

    Science.gov (United States)

    Badescu, Mircea; Sherrit, Stewart; Lewis, Derek; Bao, Xiaoqi; Bar-Cohen, Yoseph; Hall, Jeffery L.

    2016-04-01

    To address the challenges, which are involved with the development of flow control valves that can meet high demand requirements such as high pressure, high flow rate, limited power and limited space, the authors have conceived a novel design configuration. This design consists of a digitalized flow control valve with multipath and multistage pressure reduction structures. Specifically, the valve is configured as a set of parallel flow paths from the inlet to the outlet. A choke valve controls the total flow rate by digitally opening different paths or different combination of the paths. Each path is controlled by a poppet cap valve basically operated in on-off states. The number of flow states is 2N where N is the number of flow paths. To avoid erosion from sand in the fluid and high speed flow, the seal area of the poppet cap valve is located at a distance from the flow inlet away from the high speed flow and the speed is controlled to stay below a predefined erosion safe limit. The path is a multistage structure composed of a set of serial nozzles-expansion chambers that equally distribute the total pressure drop to each stage. The pressure drop of each stage and, therefore, the flow speed at the nozzles and expansion chambers is controlled by the number of stages. The paths have relatively small cross section and could be relatively long for large number of stages and still fit in a strict annular space limit. The paper will present the design configuration, analysis and preliminary test results.

  14. Ionic/Electronic Conductivity, Thermal/Chemical Expansion and Oxygen Permeation in Pr and Gd Co-Doped Ceria PrxGd0.1Ce0.9-xO1.95-δ

    DEFF Research Database (Denmark)

    Cheng, Shiyang; Chatzichristodoulou, Christodoulos; Søgaard, Martin

    2017-01-01

    The oxygen permeation flux of Ce0.9Gd0.1O1.95-δ (CGO)-based oxygen transport membranes under oxidizing conditions is limited by the electronic conductivity of the material. This work aims to enhance the bulk ambipolar conductivity of CGO by partial substitution of Ce with the redox active element...... Pr. A series of compositions of PrxGd0.1Ce0.9-xO1.95-δ (x = 0, 0.02, 0.05, 0.08, 0.15, 0.25, 0.3 and 0.4) was prepared by solid state reaction. X-ray powder diffraction (XPD) indicates that Pr is completely dissolved in the fluorite structure up to 40 at.%. Pronounced nonlinear thermal expansion...... behavior was observed as a function of temperature, due to the simultaneous contributions of both thermal and chemical expansion. The electronic and ionic conductivities were measured as a function of temperature and oxygen partial pressure. Within the range from 10 to 15 at.% Pr, a drastic drop...

  15. Valve radio and audio repair handbook

    CERN Document Server

    MILLER, CHAS

    2000-01-01

    This book is not only an essential read for every professional working with antique radio and gramophone equipment, but also dealers, collectors and valve technology enthusiasts the world over. The emphasis is firmly on the practicalities of repairing and restoring, so technical content is kept to a minimum, and always explained in a way that can be followed by readers with no background in electronics. Those who have a good grounding in electronics, but wish to learn more about the practical aspects, will benefit from the emphasis given to hands-on repair work, covering mechanical as

  16. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  17. First Reported Successful Femoral Valve-in-Valve Transcatheter Aortic Valve Replacement Using the Edwards Sapien 3 Valve.

    Science.gov (United States)

    Fournier, Stephane; Monney, Pierre; Roguelov, Christan; Zuffi, Andrea; Iglesias, Juan F; Qanadli, Salah D; Courbon, Cecile; Eeckhout, Eric; Muller, Olivier

    2015-10-01

    Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

  18. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-02-01

    Full Text Available Aim: Valve diseases in developing countries like Turkey which often occur as a complication of rheumatic fever are a serious disease. Surgical treatment of valve diseases should be done before irreversible damage to the myocardium occurred. In this study, we aimed to present the early results of mechanical valve replacement operations. Method: A hundred patients with mechanical valve replacement surgery were retrospectively evaluated in Seyhan Application Center attached to our clinic between July 2007 and August 2011. Results: Fifty patients were male and 50 were women. The mean age of patients was 47.88 (18-78. Isolated aortic valve replacement (AVR was performed to 23 patients, isolated mitral valve replacement (MVR was 32, double valve replacement (AVR + MVR was 12, MVR + aortic valve valvuloplasty was 1, AVR + mitral kommissurotomi was 1, AVR + coronary artery bypass graft surgery (CABG was 17, MVR + CABG was 8, MVR + atrial septal defect closure was 2 and Bentall procedure.was 4 patients. In addition, ablation procedure was performed to 5 patients intraoperatively because of preoperative atrial fibrillation. Two patients (2 % died in early postoperative period. Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1.000: 49-54

  19. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  20. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  1. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  2. Thermo-electric valve

    Science.gov (United States)

    Chamberland, R. R.; Stanland, A. J.

    1985-02-01

    A thermo-electric valve is described for scuttling floating devices comprising, a cylindrical sleeve affixed to and passing through a bulkhead separating a pressurized medium on one side from a lower pressure space on the other side, a piston moveably mounted within the sleeve bore and exposed to the pressurized medium having a portion thereof blocking the sleeve bore, an O-ring sealing the gap between the piston head and the sleeve bore, a fully compressed spring pressing against the piston, a rigid dielectric washer and a low power resistor holding the piston against the spring. In operation a low current is passed through the resistor, disintegrating it and releasing the spring's stored energy. This actuates the valve by expelling the piston which allows the pressurized fluid or gas to enter the lower pressure space.

  3. Effects of pressure and temperature on gate valve unwedging

    Energy Technology Data Exchange (ETDEWEB)

    Damerell, P.S.; Harrison, D.H.; Hayes, P.W.; Simons, J.W.; Walker, T.A.

    1996-12-01

    The stem thrust required to unwedge a gate valve is influenced by the pressure and temperature when the valve is closed and by the changes in these conditions between closure and opening. {open_quotes}Pressure locking{close_quotes} and {open_quotes}thermal binding{close_quotes} refer to situations where pressure and temperature effects cause the unwedging load to be much higher than normal. A model of these phenomena has been developed. Wedging (closure) is modeled as developing an {open_quotes}interference{close_quotes} between the disk and its seat rings in the valve. The effects of pressure and temperature are analyzed to determine the change in this disk-to-seat {open_quotes}interference{close_quotes}. Flexibilities, of the disk, body, stem and yoke strongly influence the unwedging thrust. Calculations and limited comparisons to data have been performed for a range of valve designs and scenarios. Pressure changes can increase the unwedging load when there is either a uniform pressure decrease, or a situation where the bonnet pressure exceeds the pressures in the adjacent piping. Temperature changes can increase the unwedging load when: (1) valve closure at elevated system temperature produces a delayed stem expansion, (2) a temperature increase after closure produces a bonnet pressure increase, or (3) a temperature change after closure produces an increase in the disk-to-seat {open_quotes}interference{close_quotes} or disk-to-seat friction.

  4. Patents and heart valve surgery--I: mechanical valves.

    Science.gov (United States)

    Cheema, Faisal H; Hussain, Nasir; Kossar, Alexander P; Polvani, Gianluca

    2013-04-01

    Valvular heart disease, inherited or acquired, affects more than 5 million Americans yearly. Whereas medical treatment is beneficial in the initial stages of valvular heart disease, surgical correction provides symptomatic relief and long-term survival benefits. Surgical options include either repair or replacement using mechanical or bio-prosthetic valves. Patient age and the post-operative need for anticoagulation therapy are major determinants of the choice between use of mechanical or bio-prosthetic valves. Since the first mechanical valves were made available several decades ago, the incorporation of increasingly sophisticated materials and methodologies has led to substantial improvements in the valve design, and has catalyzed a parallel increase in the amount of patents issued for these emerging technologies. In this paper, we have chronologically reviewed such patents, briefly discussed various challenges that mechanical heart valve implementation is faced with and finally reviewed some of the strategies employed to overcome such obstacles. An ideal prosthetic heart valve would comprehensively mimic the natural hemodynamics and physiology of the native heart valve. Additionally, such a valve would be easily implantable, associated with a minimal risk of thrombosis and thus need for anti-coagulation, and with a proven long-term durability. With cutting edge technological advancements in the recent times, the ongoing innovative and collaborative efforts of physicians, scientists, and engineers will not seize until an ideal mechanical heart valve becomes a reality.

  5. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...... and southern European countries. Imbalances in the prevalence of rheumatic heart disease, health resource availability and variations in surgical practice throughout Europe might be possible etiological causes....

  6. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  7. Optothermally actuated capillary burst valve

    Science.gov (United States)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders; Marie, Rodolphe

    2017-04-01

    We demonstrate the optothermal actuation of individual capillary burst valves in an all-polymer microfluidic device. The capillary burst valves are realised in a planar design by introducing a fluidic constriction in a microfluidic channel of constant depth. We show that a capillary burst valve can be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett. 10, 826-832 (2010)]. An individual valve is burst by focusing the laser in its vicinity. We demonstrate the capture of single polystyrene 7 μm beads in the constriction triggered by the bursting of the valve.

  8. Update of transcatheter valve treatment.

    Science.gov (United States)

    Liu, Xian-bao; Wang, Jian-an

    2013-08-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair--MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed.

  9. Mitral valve repair versus replacement

    Science.gov (United States)

    Keshavamurthy, Suresh; Gillinov, A. Marc

    2015-01-01

    Degenerative, ischemic, rheumatic and infectious (endocarditis) processes are responsible for mitral valve disease in adults. Mitral valve repair has been widely regarded as the optimal surgical procedure to treat mitral valve dysfunction of all etiologies. The supporting evidence for repair over replacement is strongest in degenerative mitral regurgitation. The aim of the present review is to summarize the data in each category of mitral insufficiency and to provide recommendations based upon this data. PMID:26309824

  10. Anatomy and formation of congenital bicuspid and quadricuspid pulmonary valves in Syrian hamsters.

    Science.gov (United States)

    Fernández, B; Fernández, M C; Durán, A C; López, D; Martire, A; Sans-Coma, V

    1998-01-01

    Congenital bicuspid and quadricuspid pulmonary valves have received little attention because of their limited clinical relevance. However, knowledge of the mechanisms by which these anomalous valves develop is essential to obtain a more accurate survey of the etiological factors implicated in the malformations of the cardiac outflow tract in mammals. The present study was designed to assess the anatomical features of bicuspid and quadricuspid pulmonary valves in Syrian hamsters as well as to elucidate the mechanisms involved in the formation of these defective valves. The sample examined consisted of 206 adults and 28 embryos belonging to a laboratory-inbred family of Syrian hamsters with a high incidence of congenital anomalies of the pulmonary and aortic valves. The study was carried out using histological techniques for light microscopy, semithin sections, and scanning electron microscopy. The pulmonary valve was tricuspid in 140 of the 206 adult hamsters, and in 124 of these tricuspid valves the dorsal commissure was more or less extensively fused. Another 45 hamsters possessed a bicuspid pulmonary valve with the sinuses oriented ventrodorsally. In 43 of these bicuspid valves, a raphe was located in the dorsal pulmonary sinus. The pulmonary valve was quadricuspid in a further nine specimens. The remaining 12 hamsters had a tricuspid pulmonary valve with a raphe-like ridge located in the right pulmonary sinus. In seven of these valves, the dorsal commissure showed a more or less extensive fusion. The embryos examined, aged between 11 days, 3 hours and 12 days, 6 hours postcoitum, were at the beginning of the valvulogenesis. In five of the 28 embryos, the pulmonary valve consisted of three mesenchymal valve cushions, right, left, and dorsal. In a further 17 embryos, the right and left valve cushions were more or less fused toward the lumen of the pulmonary artery. In the remaining six embryos, the left and dorsal valve cushions were normal, whereas the right

  11. Metallurgical analysis of failed Björk-Shiley cardiac valve prostheses.

    Science.gov (United States)

    Sacks, S H; Harrison, M; Bischler, P J; Martin, J W; Watkins, J; Gunning, A

    1986-01-01

    An investigation into the mechanisms of failure of current Björk-Shiley cardiac valve prostheses is reported. Two failed valves, one apparently unfailed but defective valve, and one unused valve, were examined by scanning electron microscopy and metallographic section. In the first two valves (removed 12 and 23 months after implantation) fracture was associated with the welds joining the short strut to the valve ring. The fracture surfaces in all cases were heavily faceted and showed branching cracks. Extensive wear had occurred on one fracture surface in the first case, suggesting that one leg of the short strut had failed before the other, though this had been clinically undetectable. The third valve was removed owing to failure of the suturing (24 months after implantation) but one leg of the short strut was found to be completely fractured. The other leg showed extensive cracking and porosity in the weld region. A metallographic section taken through the weld region of the fourth (unused) valve illustrated several sizable defects directly attributable to the welding process. It is suggested that the valves failed by fatigue and that these problems could be overcome if the complete valve cage were machined as a single piece. Images PMID:3704981

  12. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  13. Supercritical Carbon Dioxide–Based Sterilization of Decellularized Heart Valves

    Directory of Open Access Journals (Sweden)

    Ryan S. Hennessy, MD

    2017-02-01

    Full Text Available Summary: Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid– and supercritical carbon dioxide–treated valves were found to be sterile using histology, microbe culture, and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide–treated valves were higher compared with valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Key Words: decellularized, decontamination, heart valve, tensile properties, tissue engineering

  14. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural...

  15. In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves.

    Science.gov (United States)

    Simonato, Matheus; Azadani, Ali N; Webb, John; Leipsic, Jonathon; Kornowski, Ran; Vahanian, Alec; Wood, David; Piazza, Nicolo; Kodali, Susheel; Ye, Jian; Whisenant, Brian; Gaia, Diego; Aziz, Mina; Pasala, Tilak; Mehilli, Julinda; Wijeysundera, Harindra C; Tchetche, Didier; Moat, Neil; Teles, Rui; Petronio, Anna Sonia; Hildick-Smith, David; Landes, Uri; Windecker, Stephan; Arbel, Yaron; Mendiz, Oscar; Makkar, Raj; Tseng, Elaine; Dvir, Danny

    2016-09-18

    Transcatheter heart valve (THV) implantation in failed bioprosthetic valves (valve-in-valve [ViV]) offers an alternative therapy for high-risk patients. Elevated post-procedural gradients are a significant limitation of aortic ViV. Our objective was to assess the relationship between depth of implantation and haemodynamics. Commercially available THVs used for ViV were included in the analysis (CoreValve Evolut, SAPIEN XT and the Portico valve). THVs were implanted in small surgical valves (label size 19 mm) to simulate boundary conditions. Custom-mounted pulse duplicators registered relevant haemodynamic parameters. Twenty-eight experiments were performed (13 CVE, 5 SXT and 10 Portico). Ranges of depth of implantation were: CVE: -1.2 mm to 15.7 mm; SXT: -2.2 mm to 7.5 mm; Portico: 1.4 mm to 12.1 mm. Polynomial regression established a relationship between depth of implantation and valvular mean gradients (CVE: p<0.001; SXT: p=0.01; Portico: p=0.002), as well as with EOA (CVE: p<0.001; SXT: p=0.02; Portico valve: p=0.003). In addition, leaflet coaptation was better in the high implantation experiments for all valves. The current comprehensive bench testing assessment demonstrates the importance of high device position for the attainment of optimal haemodynamics during aortic ViV procedures.

  16. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  17. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...

  18. Butterfly valve apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Ball, L.K.; Hines, M.U.; Miller, T.L.

    1990-10-23

    This patent describes a method of controlling fluid flow in a duct, and duct having a wall bounding a flow path wherein flows the fluid. It comprises: disposing a plate-like valve member in the flow path, which valve member is pivotally movable about an axis generally transverse to the duct between a first position transverse to and closing the flow path and a second position generally parallel with the flow path to open and allow fluid flow therein: transecting the valve member with the pivot axis to define with respect to direction of the fluid flow in the duct and pivotal movement of the valve member toward the open position an upstream valve member wing and a downstream valve member wing each substantially equal in area: increasing the effective area of the valve member upon which the fluid flow exerts fluid dynamic flow forces; and pivoting the valve member toward the second open position thereof in response to the increase of effective area.

  19. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-03-01

    Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1: 49-54

  20. Development of the spin valve transistor (invited paper)

    NARCIS (Netherlands)

    Monsma, D.J.; Vlutters, R.; Shimatsu, T.; Shimatsu, T.; Keim, Enrico G.; Mollema, R.H.; Lodder, J.C.

    1997-01-01

    As the easiest experimental approach, GMR (giant magnetoresistance) is usually measured using the current in plane (CIP)-GMR. The spin-valve transistor has previously been presented as a spectroscopic tool to measure current perpendicular to the planes (CPP)-GMR. Hot electrons cross the magnetic

  1. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    Science.gov (United States)

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Bridges Expansion Joints

    OpenAIRE

    Sergey W. Kozlachkow

    2012-01-01

    The survey is concerned with the expansion joints, used in bridge constructions to compensate medium and significant operational linear and spatial displacements between adjacent spans or between bridge span and pier. The analysis of design features of these types of expansion joints, their advantages and disadvantages, based on operational experience justified the necessity to design constructions, meeting the modern demands imposed to expansion joints.

  3. Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure.

    Science.gov (United States)

    D'Amore, Antonio; Luketich, Samuel K; Raffa, Giuseppe M; Olia, Salim; Menallo, Giorgio; Mazzola, Antonino; D'Accardi, Flavio; Grunberg, Tamir; Gu, Xinzhu; Pilato, Michele; Kameneva, Marina V; Badhwar, Vinay; Wagner, William R

    2018-01-01

    Valvular heart disease is currently treated with mechanical valves, which benefit from longevity, but are burdened by chronic anticoagulation therapy, or with bioprosthetic valves, which have reduced thromboembolic risk, but limited durability. Tissue engineered heart valves have been proposed to resolve these issues by implanting a scaffold that is replaced by endogenous growth, leaving autologous, functional leaflets that would putatively eliminate the need for anticoagulation and avoid calcification. Despite the diversity in fabrication strategies and encouraging results in large animal models, control over engineered valve structure-function remains at best partial. This study aimed to overcome these limitations by introducing double component deposition (DCD), an electrodeposition technique that employs multi-phase electrodes to dictate valve macro and microstructure and resultant function. Results in this report demonstrate the capacity of the DCD method to simultaneously control scaffold macro-scale morphology, mechanics and microstructure while producing fully assembled stent-less multi-leaflet valves composed of microscopic fibers. DCD engineered valve characterization included: leaflet thickness, biaxial properties, bending properties, and quantitative structural analysis of multi-photon and scanning electron micrographs. Quasi-static ex-vivo valve coaptation testing and dynamic organ level functional assessment in a pressure pulse duplicating device demonstrated appropriate acute valve functionality. Copyright © 2017. Published by Elsevier Ltd.

  4. High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Harold Schock; Farhad Jaberi; Ahmed Naguib; Guoming Zhu; David Hung

    2007-12-31

    This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when

  5. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  6. An Analytic Approach to Cascade Control Design for Hydraulic Valve-Cylinder Drives

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Hansen, Anders Hedegaard; Andersen, Torben O.

    2016-01-01

    Motion control design for hydraulic drives remains to be a complicated task, and has not evolved on a level with electrical drives. When considering specifically motion control of hydraulic drives, the industry still prefers conventional linear control structures, often combined with feed forward...... control and possibly linear active damping functionalities. However difficulties often arise due to the inherent and strong nonlinear nature of hydraulic drives, with the more dominant being nonlinear valve flow- and oil stiffness characteristics, and furthermore the volume expansion/retraction when......, unfortunately not present in valve-operated hydraulic drives. This paper considers a cascade control approach for hydraulic valve-cylinder drives motivated by the fact that this may be applied to successfully suppress nonlinearities. The drive is pre-compensated utilizing a pressure updated inverse valve flow...

  7. A method for evaluating pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, T.

    1996-12-01

    A method is described to evaluate the susceptibility of gate valves to pressure locking and thermal binding. Binding of the valve disc in the closed position due to high pressure water trapped in the bonnet cavity (pressure locking) or differential thermal expansion of the disk in the seat (thermal binding) represents a potential mechanism that can prevent safety-related systems from functioning when called upon. The method described here provides a general equation that can be applied to a given gate valve design and set of operating conditions to determine the susceptibility of the valve to fail due to disc binding. The paper is organized into three parts. The first part discusses the physical mechanisms that cause disc binding. The second part describes the mathematical equations. The third part discusses the conclusions.

  8. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  9. On skin expansion.

    Science.gov (United States)

    Pamplona, Djenane C; Velloso, Raquel Q; Radwanski, Henrique N

    2014-01-01

    This article discusses skin expansion without considering cellular growth of the skin. An in vivo analysis was carried out that involved expansion at three different sites on one patient, allowing for the observation of the relaxation process. Those measurements were used to characterize the human skin of the thorax during the surgical process of skin expansion. A comparison between the in vivo results and the numerical finite elements model of the expansion was used to identify the material elastic parameters of the skin of the thorax of that patient. Delfino's constitutive equation was chosen to model the in vivo results. The skin is considered to be an isotropic, homogeneous, hyperelastic, and incompressible membrane. When the skin is extended, such as with expanders, the collagen fibers are also extended and cause stiffening in the skin, which results in increasing resistance to expansion or further stretching. We observed this phenomenon as an increase in the parameters as subsequent expansions continued. The number and shape of the skin expanders used in expansions were also studied, both mathematically and experimentally. The choice of the site where the expansion should be performed is discussed to enlighten problems that can lead to frustrated skin expansions. These results are very encouraging and provide insight into our understanding of the behavior of stretched skin by expansion. To our knowledge, this study has provided results that considerably improve our understanding of the behavior of human skin under expansion. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  11. Management of a locked Strata valve.

    Science.gov (United States)

    Bullivant, Kelly J; Mitha, Alim P; Hamilton, Mark G

    2009-04-01

    The PS Medical Strata valve is a programmable shunt valve used in the treatment of hydrocephalus that allows for noninvasive changes in the pressure setting using a magnet. The Strata valve is sensitive to magnetic fields, and reprogramming is frequently necessary after MR imaging. A known but rare complication of the Strata valve is that the rotor can become locked, causing shunt malfunction. This complication can only occur in a first generation Strata valve.

  12. 3D Printed Multimaterial Microfluidic Valve

    OpenAIRE

    Keating, Steven J.; Gariboldi, Maria Isabella; Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deform...

  13. Treatment of Aortic, Mitral and Tricuspid Structural Bioprosthetic Valve Deterioration Using the Valve-in-Valve Technique.

    Science.gov (United States)

    Codner, Pablo; Assali, Abid; Vaknin-Assa, Hana; Shapira, Yaron; Orvin, Katia; Sharony, Ram; Sagie, Alexander; Kornowski, Ran

    2015-05-01

    The percutaneous approach for a failed bioprosthetic valve is an emerging alternative to redo-valve surgery in patients at high surgical risk. The study aim was to describe the treatment of patients with structural bioprosthetic valve deterioration, using the valve-in-valve technique. A total of 33 consecutive patients with symptomatic structural bioprosthetic valve deterioration was treated at the authors' institution, using the valve-in-valve technique. The valve-in-valve procedure in the aortic position was performed in 23 patients (mean age 81.4 ± 5.9 years; mean STS score 9.6 ± 5.4). The self-expandable and balloon-expandable devices were used in 21 cases (91.3%) and two cases (8.7%), respectively. Procedures were performed via the trans-femoral, trans-axillary and trans-apical routes in 18 (78.2%), three (13%) and two (8.7%) cases, respectively. After the procedure, all patients were in NYHA class I/II. Survival rates were 95.6% at the one-year follow up. The valve-in-valve procedure in the mitral position was performed in 10 patients (mean age 73.6 ± 15 years; mean STS score 7.7 ± 4.1). All procedures were performed using the balloon-expandable device via the trans-apical route. The composite end point of device success was achieved in all patients. Survival rates were 100% and 75% at one month and two years' follow up, respectively. A single valve-in-valve implantation within a failed tricuspid bioprosthetic valve was also successfully performed. In the authors' experience, the valve-in-valve technique for the treatment of a wide range of bioprosthetic valve deterioration modes of failure in different valve positions is safe and very effective.

  14. The expansion of polarization charge layers into magnetized vacuum - Theory and computer simulations

    Science.gov (United States)

    Galvez, Miguel; Borovsky, Joseph E.

    1991-01-01

    The formation and evolution of polarization charge layers on cylindrical plasma streams moving in vacuum are investigated using analytic theory and 2D electrostatic particle-in-cell computer simulations. It is shown that the behavior of the electron charge layer goes through three stages. An early time expansion is driven by electrostatic repulsion of electrons in the charge layer. At the intermediate stage, the simulations show that the electron-charge-layer expansion is halted by the positively charged plasma stream. Electrons close to the stream are pulled back to the stream and a second electron expansion follows in time. At the late stage, the expansion of the ion charge layer along the magnetic field lines accompanies the electron expansion to form an ambipolar expansion. It is found that the velocities of these electron-ion expansions greatly exceed the velocities of ambipolar expansions which are driven by plasma temperatures.

  15. Ranking Medical Terms to Support Expansion of Lay Language Resources for Patient Comprehension of Electronic Health Record Notes: Adapted Distant Supervision Approach.

    Science.gov (United States)

    Chen, Jinying; Jagannatha, Abhyuday N; Fodeh, Samah J; Yu, Hong

    2017-10-31

    Medical terms are a major obstacle for patients to comprehend their electronic health record (EHR) notes. Clinical natural language processing (NLP) systems that link EHR terms to lay terms or definitions allow patients to easily access helpful information when reading through their EHR notes, and have shown to improve patient EHR comprehension. However, high-quality lay language resources for EHR terms are very limited in the public domain. Because expanding and curating such a resource is a costly process, it is beneficial and even necessary to identify terms important for patient EHR comprehension first. We aimed to develop an NLP system, called adapted distant supervision (ADS), to rank candidate terms mined from EHR corpora. We will give EHR terms ranked as high by ADS a higher priority for lay language annotation-that is, creating lay definitions for these terms. Adapted distant supervision uses distant supervision from consumer health vocabulary and transfer learning to adapt itself to solve the problem of ranking EHR terms in the target domain. We investigated 2 state-of-the-art transfer learning algorithms (ie, feature space augmentation and supervised distant supervision) and designed 5 types of learning features, including distributed word representations learned from large EHR data for ADS. For evaluating ADS, we asked domain experts to annotate 6038 candidate terms as important or nonimportant for EHR comprehension. We then randomly divided these data into the target-domain training data (1000 examples) and the evaluation data (5038 examples). We compared ADS with 2 strong baselines, including standard supervised learning, on the evaluation data. The ADS system using feature space augmentation achieved the best average precision, 0.850, on the evaluation set when using 1000 target-domain training examples. The ADS system using supervised distant supervision achieved the best average precision, 0.819, on the evaluation set when using only 100 target

  16. The surface microstructure of cusps and leaflets in rabbit and mouse heart valves

    Directory of Open Access Journals (Sweden)

    Xia Ye

    2014-05-01

    Full Text Available In this investigation, scanning electron microscopy was used to characterize the microstructure on the surfaces of animal heart valve cusps/leaflets. The results showed that though these surfaces appear smooth to the naked eye, they are actually comprised of a double hierarchical structure consisting of a cobblestone-like microstructure and nano-cilia along with mastoids with a directional arrangement. Such nanostructures could play a very important role in the hemocompatibility characteristics of heart valves. On this basis, the model of the microstructure was constructed and theoretical analysis was used to obtain optimal geometric parameters for the rough surface of artificial valve cusps/leaflets. This model may help improve reconstructive techniques and it may be beneficial in the design and fabrication of valve substitutes or partial substitutes. Namely, the model may help ameliorate heart valve replacement surgery.

  17. Bridges Expansion Joints

    Directory of Open Access Journals (Sweden)

    Sergey W. Kozlachkow

    2012-05-01

    Full Text Available The survey is concerned with the expansion joints, used in bridge constructions to compensate medium and significant operational linear and spatial displacements between adjacent spans or between bridge span and pier. The analysis of design features of these types of expansion joints, their advantages and disadvantages, based on operational experience justified the necessity to design constructions, meeting the modern demands imposed to expansion joints.

  18. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). Conclusions-High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self-and balloon-expandable transcatheter......Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets...... for implantation that would improve hemodynamics after ViV. Methods and Results-Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated...

  19. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  20. Bridges Expansion Joints

    National Research Council Canada - National Science Library

    Sergey W. Kozlachkow

    2012-01-01

    .... The analysis of design features of these types of expansion joints, their advantages and disadvantages, based on operational experience justified the necessity to design constructions, meeting...

  1. Exact e-e (exchange) correlations of 2-D quantum dots in magnetic field: Size extensive N = 3 , 4 , … , ‧ n ‧ -electron systems via multi-pole expansion

    Science.gov (United States)

    Aggarwal, Priyanka; Sharma, Shivalika; Singh, Sunny; Kaur, Harsimran; Hazra, Ram Kuntal

    2017-04-01

    Inclusion of coulomb interaction emerges with the complexity of either convergence of integrals or separation of variables of Schrödinger equations. For an N-electron system, interaction terms grow by N(N-1)/2 factors. Therefore, 2-e system stands as fundamental basic unit for generalized N-e systems. For the first time, we have evaluated e-e correlations in very simple and absolutely terminating finite summed hypergeometric series for 2-D double carrier parabolic quantum dot in both zero and arbitrary non-zero magnetic field (symmetric gauge) and have appraised these integrals in variational methods. The competitive role among confinement strength, magnetic field, mass of the carrier and dielectric constant of the medium on energy level diagram, level-spacing statistics, heat capacities (Cv at 1 K) and magnetization (T ∼ (0-1)K) is studied on systems spanning over wide range of materials (GaAs,Ge,CdS,SiO2 and He, etc). We have also constructed an exact theory for generalized correlated N-e 2-D quantum dots via multi-pole expansion but for the sake of compactness of the article we refrain from data.

  2. Sutureless Valves Reduce Hospital Costs Compared to Traditional Valves.

    Science.gov (United States)

    Laborde, François; Folliguet, Thierry; Ghorayeb, Gabriel; Zannis, Konstantinos

    2017-01-01

    The study aim was to assess differences in clinical outcome, safety, and associated costs between sutureless and aortic isolated aortic valve replacement (AVR) with a standard bioprosthesis. A retrospective comparative study was conducted to investigate 65 patients, each of whom had undergone isolated AVR with a traditional aortic valve (T) or a Perceval S sutureless aortic prosthesis (P) between January 2010 and December 2012. Cost data were drawn from the proprietary cost accounting system of the hospital, excluding acquisition costs of the devices. A linear regression model was used to estimate the mean total costs difference between groups. The mean cardiopulmonary bypass time and aortic cross-clamp times in the T and P groups were 80 ± 41 min and 58 ± 26 min versus 38 ± 16 min and 26 ± 10 min, respectively (p costs savings for group P compared to group T were €3,801 (p = 0.13), mainly driven by hospital stay costs. Savings between the P and T groups increased with age: €4,992 in patients aged 70-79 years and €9,326 in those aged 80+ years, and with risk (€4,296 for high-risk patients). Sutureless aortic valves present shorter procedural times and lower hospital costs compared to traditional valves, with higher cost savings at increased patient age and risk. Sutureless aortic valves seem to be cost-effective in patients undergoing AVR.

  3. Robotically assisted mitral valve replacement.

    Science.gov (United States)

    Gao, Changqing; Yang, Ming; Xiao, Cangsong; Wang, Gang; Wu, Yang; Wang, Jiali; Li, Jiachun

    2012-04-01

    In the present study, we determined the safety and efficacy of robotic mitral valve replacement using robotic technology. From January 2007 through March 2011, more than 400 patients underwent various types of robotic cardiac surgery in our department. Of these, 22 consecutive patients underwent robotically assisted mitral valve replacement. Of the 22 patients with isolated rheumatic mitral valve stenosis (9 men and 13 women), the mean age was 44.7 ± 19.8 years (range, 32-65). Preoperatively, all patients underwent a complete workup, including coronary angiography and transthoracic echocardiography. Of the 22 patients, 15 had concomitant atrial fibrillation. The surgical approach was through 4 right-side chest ports with femoral perfusion. Aortic occlusion was performed with a Chitwood crossclamp, and antegrade cardioplegia was administered directly by way of the anterior chest. Using 3 port incisions in the right side of the chest and a 2.5- to 3.0-cm working port, all the procedures were completed with the da Vinci S robot. All patients underwent successful robotic surgery. Of the 22 patients, 16 received a mechanical valve and 6 a tissue valve. The mean cardiopulmonary bypass time and aortic crossclamp time was 137.1 ± 21.9 minutes (range, 105-168) and 99.3 ± 17.9 minutes (range, 80-133), respectively. No operative deaths, stroke, or other complications occurred, and no incisional conversions were required. After surgery, all the patients were followed up echocardiographically. Robotically assisted mitral valve replacement can be performed safely in patients with isolated mitral valve stenosis, and surgical results are excellent. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  4. What Are the Signs and Symptoms of Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  5. Strain effects on anisotropic magnetoresistance in a nanowire spin valve

    Science.gov (United States)

    Hossain, Md I.; Maksud, M.; Subramanian, A.; Atulasimha, J.; Bandyopadhyay, S.

    2016-11-01

    The longitudinal magnetoresistance of a copper nanowire contacted by two cobalt contacts shows broad spin-valve peaks at room temperature. However, when the contacts are slightly heated, the peaks change into troughs which are signature of anisotropic magnetoresistance (AMR). Under heating, the differential thermal expansion of the contacts and the substrate generates a small strain in the cobalt contacts which enhances the AMR effect sufficiently to change the peak into a trough. This shows the extreme sensitivity of AMR to strain. The change in the AMR resistivity coefficient due to strain is estimated to be a few m Ω -m/microstrain.

  6. Butterfly valve of all rubber lining type

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Shosaku; Nakatsuma, Sumiya (Kubota Ltd., Osaka (Japan)); Sasaki, Iwao; Aoki, Naoshi

    1982-08-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported.

  7. Mitral valve aneurysm associated with aortic valve endocarditis and regurgitation.

    Science.gov (United States)

    Raval, Amish N; Menkis, Alan H; Boughner, Derek R

    2002-01-01

    Mitral valve aneurysms are rare complications occurring most commonly in association with aortic valve infective endocarditis. [Decroly 1989, Chua 1990, Northridge 1991, Karalis 1992, Roguin 1996, Mollod 1997, Vilacosta 1997, Cai 1999, Vilacosta 1999, Teskey 1999, Chan 2000, Goh 2000, Marcos- Alberca 2000] While the mechanism of the development of this lesion is unclear, complications such as perforation can occur and lead to significant mitral regurgitation. [Decroly 1989, Karalis 1992, Teskey 1999, Vilacosta 1999]; The case of a 69-year-old male with Streptococcus Sanguis aortic valve endocarditis and associated anterior mitral leaflet aneurysm is presented. Following surgery, tissue pathology of the excised lesion revealed myxomatous degeneration and no active endocarditis or inflammatory cells. This may add support to the hypothesis that physical stress due to severe aortic insufficiency and structural weakening, without infection of the anterior mitral leaflet, can lead to the development of this lesion.

  8. Valved stent for off-pump mitral valve replacement

    OpenAIRE

    Ma, L.(School of Physics, Shandong University, Shandong, China)

    2004-01-01

    Résumé Objectif : Evaluer un remplacement de valve mitrale hors-pompe avec des stents valvés Méthode: Des homografts préservés dans du glutaraldehyde ont été suturés dans une prothèse tubulaire avant d'être soudés à deux stents Z en nitinol pour créer deux couronnes auto- extensibles. A) Nous avons testé la valve in vitro en utilisant un circuit pulsatile fermé (mock loop) ayant de débuter les expériences sur les porcs. (n=8, 46 .0± 4.3 kg : B). L'oreillette gauche a été exposée p...

  9. Mechanical heart valve cavitation in patients with bileaflet valves.

    Science.gov (United States)

    Johansen, Peter; Andersen, Tina S; Hasenkam, J Michael; Nygaard, Hans; Paulsen, Peter K

    2014-01-01

    Today, the quality of mechanical heart valves is quite high, and implantation has become a routine clinical procedure with a low operative mortality (mechanism found to be a possible contributor to these adverse effects is cavitation. In vitro, cavitation has been directly demonstrated by visualization and indirectly in vivo by registering of high frequency pressure fluctuations (HFPF). Tilting disc valves are thought of having higher cavitation potential than bileaflet valves due to higher closing velocities. However, the thromboembolic potential seems to be the same. Further studies are therefore needed to investigate the cavitation potential of bileaflet valves in vivo. The post processing of HFPF have shown difficulties when applied on bileaflet vavles due to asynchronous closure of the two leaflets. The aim of this study was therefore to isolate the pressure signature from each leaflet closure and perform cavitation analyses on each component. Six patients were included in the study (St. Jude Medical (n=3) and CarboMedics (n=3); all aortic bileaflet mechanical heart valves). HFPFs were recorded intraoperatively through a hydrophone at the aortic root. The pressure signature relating to the first and second leaflet closure was isolated and cavitation parameters were calculated (RMS after 50 kHz highpass filtering and signal energy). Data were averaged over 30 heart cycles. For all patients both the RMS value and signal energy of the second leaflet closure were higher than for the first leaflet closure. This indicates that the second leaflet closure is most prone to cause cavitation. Therefore, quantifying cavitation based on the HFPF related to the second leaflet closure may suggest that the cavitation potential for bileaflet valves in vivo may be higher than previous studies have suggested.

  10. Minimally Invasive Heart Valve Surgery.

    Science.gov (United States)

    Bouhout, Ismail; Morgant, Marie-Catherine; Bouchard, Denis

    2017-09-01

    Minimally invasive valve surgery represents a recent and significant advance in modern heart surgery. Indeed, many less invasive approaches for both the aortic and mitral valves have been developed in the past 2 decades. These procedures were hypothesized to result in less operative trauma, which might translate into better patient outcomes. However, this clinical benefit remains controversial in the literature. The aim of this review is to discuss the evidence surrounding minimally invasive heart valve surgery in the current era. A systematic search of the literature from 2006-2016 was performed looking for articles reporting early or late outcomes after minimally invasive valve surgery. Less invasive valve surgery is safe and provides long-term surgical outcomes similar to those of standard sternotomy. In addition, these approaches result in a reduction in overall hospital length of stay and may mitigate the risk of early morbidity-mainly postoperative bleeding, transfusions, and ventilation duration. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive...... in Denmark who had received a Mitroflow aortic bioprosthesis since 2000. METHODS: Patients alive in Denmark with a Mitroflow bioprosthesis implanted since January 2000 were invited to participate in a nationwide cross-sectional study with a predefined definition of SVD. Of 1552 patients, 861 patients had...

  12. Development of mechanical heart valves - an inspiring tale

    Directory of Open Access Journals (Sweden)

    P Rajashekar

    2015-01-01

    Full Text Available The historical evolution of the prosthetic heart valves from the first attempts with the Hufnagel′s valve in the treatment of the aortic insufficiency to the Starr-Edwards′ ball valve and later the tilting disc valves (Bjork-Shiley etc., and finally the bileaflet valves (St. Jude are discussed. The Indian contribution with Chitra valve is also described.

  13. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves

    Science.gov (United States)

    van Rensburg, Annari; Doubell, Anton

    2017-01-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P abnormal papillary muscles (P = 0.002) and an additional chord or tendon in the left ventricle cavity (P = 0.007). Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. PMID:28515127

  14. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  15. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves.

    Science.gov (United States)

    van Rensburg, Annari; Herbst, Philip; Doubell, Anton

    2017-06-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P mitral regurgitation (P Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. © 2017 The authors.

  16. Should a Regurgitant Mitral Valve Be Replaced Simultaneously with a Stenotic Aortic Valve?

    OpenAIRE

    Christenson, Jan T.; Jordan, Bernard; Bloch, Antoine; Schmuziger, Martin

    2000-01-01

    Mitral valve regurgitation frequently accompanies aortic valve stenosis. It has been suggested that mitral regurgitation improves after aortic valve replacement alone and that the mitral valve need not be replaced simultaneously. Furthermore, mitral regurgitation associated with coronary artery disease, particularly in patients with poor left ventricular function, shows immediate improvement after coronary artery bypass grafting.

  17. Association of altered collagen content and lysyl oxidase expression in degenerative mitral valve disease.

    Science.gov (United States)

    Purushothaman, K-Raman; Purushothaman, Meerarani; Turnbull, Irene C; Adams, David H; Anyanwu, Anelechi; Krishnan, Prakash; Kini, Annapoorna; Sharma, Samin K; O'Connor, William N; Moreno, Pedro R

    Collagen cross-linking is mediated by lysyl oxidase (LOX) enzyme in the extracellular matrix (ECM) of mitral valve leaflets. Alterations in collagen content and LOX protein expression in the ECM of degenerative mitral valve may enhance leaflet expansion and disease severity. Twenty posterior degenerative mitral valve leaflets from patients with severe mitral regurgitation were obtained at surgery. Five normal posterior mitral valve leaflets procured during autopsy served as controls. Valvular interstitial cells (VICs) density was quantified by immunohistochemistry, collagen Types I and III by picro-sirius red staining and immunohistochemistry, and proteoglycans by alcian blue staining. Protein expression of LOX and its mediator TGFβ1 were quantified by immunofluorescence and gene expression by PCR. VIC density was increased, structural Type I collagen density was reduced, while reparative Type III collagen and proteoglycan densities were increased (Pvalves. These changes were associated with a reduction in LOX (Pmitral valve leaflets. Observed changes in Type I and III collagen densities in Degenerative Mitral Valve Disease may be secondary to alterations in LOX protein expression, contributing to disorganization of ECM and disease severity. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  19. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  20. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  1. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  2. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Rho, Hyung Joon; Lee, Jee Keun [Chonbuk National Univ., Jeonju (Korea, Republic of); Choi, Hee Joo [Firstec Co., Ltd., Changwon (Korea, Republic of)

    2008-01-15

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.

  3. 49 CFR 195.420 - Valve maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each valve...

  4. Double orifice mitral valve; a coincidental finding

    NARCIS (Netherlands)

    Westendorp, Iris C. D.; de Bruin-Bon, H. A. C. M.; Hrudova, Jana

    2006-01-01

    A double orifice mitral valve (DOMV) represents a rare congenital malformation characterised by two valve orifices with two separate subvalvular apparatus. This case demonstrates the necessity of careful imaging of the mitral valve apparatus, not only in patients with atrioventricular septal

  5. Pregnancy in women with prosthetic heart valves

    NARCIS (Netherlands)

    Pieper, P. G.; Balci, A.; Van Dijk, A. P.

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis mid death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than unfractionated and low-molecular-weight heparin, but carry the risk

  6. Pregnancy in women with prosthetic heart valves.

    NARCIS (Netherlands)

    Pieper, P.G.; Balci, A.; Dijk, A.P.J. van

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis and death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than un-fractionated and low-molecular-weight heparin, but carry the risk

  7. Transcatheter mitral valve implantation via transapical approach

    DEFF Research Database (Denmark)

    Sondergaard, Lars; Brooks, Matthew; Ihlemann, Nikolaj

    2015-01-01

    OBJECTIVES: As many as 50% of patients with severe symptomatic mitral valve regurgitation are denied surgical valve replacement or repair due to high operative risk. We describe an early series of cases of transcatheter implantation with a CardiAQ™ mitral valve via a transapical approach. METHODS...

  8. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  9. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  10. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  11. [The Starr-Edwards heart valve: one of the oldest mechanical heart valves still functioning today].

    Science.gov (United States)

    Schoenaker, Michiel H; van Wetten, Herbert B; Morshuis, Wim J

    2015-01-01

    In the 1960s, the Starr-Edwards valve was the first artificial heart valve to be successfully implanted in humans. This valve has now been in use for decades with outstanding results: patients whose life expectancy had previously been short acquired a good prognosis with this development. Nowadays the Starr-Edwards valve is not used anymore, but patients are being described today in whom these valves are still functioning well after more than 40 years.

  12. Conformal expansions and renormalons

    CERN Document Server

    Brodsky, S J; Grunberg, G; Rathsman, J; Brodsky, Stanley J.; Gardi, Einan; Grunberg, Georges; Rathsman, Johan

    2001-01-01

    The coefficients in perturbative expansions in gauge theories are factoriallyincreasing, predominantly due to renormalons. This type of factorial increaseis not expected in conformal theories. In QCD conformal relations betweenobservables can be defined in the presence of a perturbative infraredfixed-point. Using the Banks-Zaks expansion we study the effect of thelarge-order behavior of the perturbative series on the conformal coefficients.We find that in general these coefficients become factorially increasing.However, when the factorial behavior genuinely originates in a renormalonintegral, as implied by a postulated skeleton expansion, it does not affect theconformal coefficients. As a consequence, the conformal coefficients willindeed be free of renormalon divergence, in accordance with previousobservations concerning the smallness of these coefficients for specificobservables. We further show that the correspondence of the BLM method with theskeleton expansion implies a unique scale-setting procedure. Th...

  13. Negative thermal expansion in framework compounds

    Indian Academy of Sciences (India)

    electron microscopy, EXAFS and differential scanning calorimetry have been used to study structural properties as a function of temperature for these compounds. In this paper we report the results obtained from our study [14–20] of negative thermal expansion (NTE) compounds with chemical compositions of NX2O8 and.

  14. Imaging of Cardiac Valves by Computed Tomography

    OpenAIRE

    Gudrun Feuchtner

    2013-01-01

    This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use ...

  15. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  16. Isolated tricuspid valve infective endocarditis

    African Journals Online (AJOL)

    1990-07-07

    Jul 7, 1990 ... Case 2. Initial chest radiograph showing rounded shadows with cavitation. Fig. 2. Case 2. Chest radiograph showing progression to effusion. nuc/eacum was Isolated from repeated blood cultures. Two- dimensional echocardiography revealed vegetations on the tricuspid valve (Fig. 3). The patient was now ...

  17. Optothermally actuated capillary burst valve

    DEFF Research Database (Denmark)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders

    2017-01-01

    be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett...

  18. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  19. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  20. Hemodynamics driven cardiac valve morphogenesis.

    Science.gov (United States)

    Steed, Emily; Boselli, Francesco; Vermot, Julien

    2016-07-01

    Mechanical forces are instrumental to cardiovascular development and physiology. The heart beats approximately 2.6 billion times in a human lifetime and heart valves ensure that these contractions result in an efficient, unidirectional flow of the blood. Composed of endocardial cells (EdCs) and extracellular matrix (ECM), cardiac valves are among the most mechanically challenged structures of the body both during and after their development. Understanding how hemodynamic forces modulate cardiovascular function and morphogenesis is key to unraveling the relationship between normal and pathological cardiovascular development and physiology. Most valve diseases have their origins in embryogenesis, either as signs of abnormal developmental processes or the aberrant re-expression of fetal gene programs normally quiescent in adulthood. Here we review recent discoveries in the mechanobiology of cardiac valve development and introduce the latest technologies being developed in the zebrafish, including live cell imaging and optical technologies, as well as modeling approaches that are currently transforming this field. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel. Copyright © 2015. Published by Elsevier B.V.

  1. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected fo...

  2. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... called stenosis). • Don’t close properly and let blood leak where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t close properly (more common in women).As pressure builds inside the left ventricle, it pushes the ...

  3. Fabrication of a novel hybrid scaffold for tissue engineered heart valve.

    Science.gov (United States)

    Hong, Hao; Dong, Nianguo; Shi, Jiawei; Chen, Si; Guo, Chao; Hu, Ping; Qi, Hongxu

    2009-10-01

    The aim of this study was to fabricate biomatrix/polymer hybrid scaffolds using an electrospinning technique. Then tissue engineered heart valves were engineered by seeding mesenchymal stromal cells (MSCs) onto the scaffolds. The effects of the hybrid scaffolds on the proliferation of seed cells, formation of extracellular matrix and mechanical properties of tissue engineered heart valves were investigated. MSCs were obtained from rats. Porcine aortic heart valves were decellularized, coated with poly(3-hydroxybutyrate-co-4-hydroxybutyrate) using an electrospinning technique, and reseeded and cultured over a time period of 14 days. In control group, the decellularized valve scaffolds were reseeded and cultured over an equivalent time period. Specimens of each group were examined histologically (hematoxylin-eosin [HE] staining, immunohistostaining, and scanning electron microscopy), biochemically (DNA and 4-hydroxyproline) and mechanically. The results showed that recellularization was comparable to the specimens of hybrid scaffolds and controls. The specimens of hybrid scaffolds and controls revealed comparable amounts of cell mass and 4-hydroxyproline (P>0.05). However, the specimens of hybrid scaffolds showed a significant increase in mechanical strength, compared to the controls (Phybrid scaffolds to increase the mechanical strength of tissue engineered heart valves. And compared to the decellularized valve scaffolds, the hybrid scaffolds showed similar effects on the proliferation of MSCs and formation of extracellular matrix. It was believed that the hybrid scaffolds could be used for the construction of tissue engineered heart valves.

  4. Mitral Valve Disease: a Comprehensive Review.

    Science.gov (United States)

    Harb, Serge C; Griffin, Brian P

    2017-08-01

    This review aims to provide a comprehensive assessment of mitral valve disease, both mitral stenosis and mitral regurgitation, starting with an overview of the valve anatomy. The advent of three-dimensional imaging has allowed a better representation of the valve anatomy. Rheumatic disease is still the number one cause of mitral stenosis worldwide and percutaneous balloon mitral valvuloplasty remains the therapy of choice when indicated and in anatomically eligible patients. Mitral regurgitation (MR) is classified as primary (i.e., lesion in the mitral apparatus) or secondary (caused by left ventricular geometrical alterations). While surgery, preferably repair, is still the recommended therapy for severe primary MR, percutaneous approaches to repair and/or replace the mitral valve are being extensively investigated. Mitral valve disease is common. A careful understanding of mitral valve anatomy and the disease processes that affect the valve are crucial for providing optimal patient care.

  5. Mitral Valve Repair: The Chordae Tendineae

    Directory of Open Access Journals (Sweden)

    Carlos-A Mestres

    2015-10-01

    Full Text Available Repair of the mitral valve is the treatment of choice for mitral valve regurgitation when the anatomy is favorable. It is well known that mitral valve repair enjoys better clinical and functional results than any other type of valve substitute. This fact is beyond doubt regardless of the etiology of the valve lesion and is of particular importance in degenerative diseases.This review analyzes the most important advances in the knowledge of the anatomy, pathophysiology, and chordal function of the mitral valve as well as the different alternatives in the surgical repair and clinical results of the most prevalent diseases of the mitral valve. An attempt has been made to organize the acquired information available in a practical way.

  6. Resonant state expansions

    Energy Technology Data Exchange (ETDEWEB)

    Lind, P.

    1993-02-01

    The completeness properties of the discrete set of bound state, virtual states and resonances characterizing the system of a single nonrelativistic particle moving in a central cutoff potential is investigated. From a completeness relation in terms of these discrete states and complex scattering states one can derive several Resonant State Expansions (RSE). It is interesting to obtain purely discrete expansion which, if valid, would significantly simplify the treatment of the continuum. Such expansions can be derived using Mittag-Leffler (ML) theory for a cutoff potential and it would be nice to see if one can obtain the same expansions starting from an eigenfunction theory that is not restricted to a finite sphere. The RSE of Greens functions is especially important, e.g. in the continuum RPA (CRPA) method of treating giant resonances in nuclear physics. The convergence of RSE is studied in simple cases using square well wavefunctions in order to achieve high numerical accuracy. Several expansions can be derived from each other by using the theory of analytic functions and one can the see how to obtain a natural discretization of the continuum. Since the resonance wavefunctions are oscillating with an exponentially increasing amplitude, and therefore have to be interpreted through some regularization procedure, every statement made about quantities involving such states is checked by numerical calculations.Realistic nuclear wavefunctions, generated by a Wood-Saxon potential, are used to test also the usefulness of RSE in a realistic nuclear calculation. There are some fundamental differences between different symmetries of the integral contour that defines the continuum in RSE. One kind of symmetry is necessary to have an expansion of the unity operator that is idempotent. Another symmetry must be used if we want purely discrete expansions. These are found to be of the same form as given by ML. (29 refs.).

  7. Conical Seat Shut-Off Valve

    Science.gov (United States)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  8. Coronary artery anomalies and aortic valve morphology in the Syrian hamster.

    Science.gov (United States)

    Fernández, M C; Durán, A C; Real, R; López, D; Fernández, B; de Andrés, A V; Arqué, J M; Gallego, A; Sans-Coma, V

    2000-04-01

    In the Syrian hamster, anomalies in the origin of the left coronary artery are significantly associated with the bicuspid condition of the aortic valve. In this species, bicuspid aortic valves are expressions of a trait, the variation of which takes the form of a phenotypic continuum, ranging from a tricuspid aortic valve with no commissural fusion to a bicuspid aortic valve with the aortic sinuses located in ventrodorsal orientation and devoid of any raphe. The intermediate stages of the continuum are represented by tricuspid aortic valves with a more or less extensive fusion of the ventral commissure and bicuspid aortic valves with a more or less developed raphe located in the ventral aortic sinus. The present study was designed to decide whether there is a gap between tricuspid and bicuspid aortic valves regarding the incidence of coronary artery anomalies, or whether this incidence varies according to the different tricuspid and bicuspid morphotypes of the continuum. The study was carried out in Syrian hamsters belonging to a single inbred family with a high incidence of tricuspid aortic valves with fusion of the ventral commissure, bicuspid aortic valves, and anomalies in the origin of the left coronary artery, i.e. single right coronary artery ostium in aorta, anomalous origin of the left coronary artery from the pulmonary artery, and anomalous origin of the left coronary artery from the dorsal aortic sinus. The specimens were examined by means of a stereomicroscope and, in several cases, scanning electron microscopy was also used. The relationships between anomalous coronary artery patterns and aortic valve morphologies were tested using a logistic regression model. The results obtained indicate that there is no discontinuity between tricuspid and bicuspid aortic valves regarding the incidence of coronary artery anomalies. The probability of occurrence of anomalous coronary artery patterns increases continuously according to the deviation degree of the

  9. Virial Expansion Bounds

    Science.gov (United States)

    Tate, Stephen James

    2013-10-01

    In the 1960s, the technique of using cluster expansion bounds in order to achieve bounds on the virial expansion was developed by Lebowitz and Penrose (J. Math. Phys. 5:841, 1964) and Ruelle (Statistical Mechanics: Rigorous Results. Benjamin, Elmsford, 1969). This technique is generalised to more recent cluster expansion bounds by Poghosyan and Ueltschi (J. Math. Phys. 50:053509, 2009), which are related to the work of Procacci (J. Stat. Phys. 129:171, 2007) and the tree-graph identity, detailed by Brydges (Phénomènes Critiques, Systèmes Aléatoires, Théories de Jauge. Les Houches 1984, pp. 129-183, 1986). The bounds achieved by Lebowitz and Penrose can also be sharpened by doing the actual optimisation and achieving expressions in terms of the Lambert W-function. The different bound from the cluster expansion shows some improvements for bounds on the convergence of the virial expansion in the case of positive potentials, which are allowed to have a hard core.

  10. Scophony light valve.

    Science.gov (United States)

    Johnson, R V

    1979-12-01

    The optical modulator in a flying spot scanner converts the electronic video signal into a corresponding temporal modulation of a light beam. An alternative configuration, which directly exploits the spatial modulation of an acoustooptic cell, is the Scophony scanner, first developed by the Scophony Laboratories of London during the 1930s. The Scophony scanner responds like a coherent imaging system, whereas the flying spot scanner performs like an incoherent imaging system, when the light source is spatially coherent. The Scophony response is intimately linked to the concepts of FM blur and the deflector as video spectrum bandpass filter.

  11. Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

    Science.gov (United States)

    El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A

    2018-01-23

    Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.

  12. Longitudinal expansion of field line dipolarization

    Science.gov (United States)

    Saka, O.; Hayashi, K.

    2017-11-01

    We examine the substorm expansions that started at 1155 UT 10 August 1994 in the midnight sector focusing on the longitudinal (eastward) expansion of field line dipolarization in the auroral zone. Eastward expansion of the dipolarization region was observed in all of the H, D, and Z components. The dipolarization that started at 1155 UT (0027 MLT) from 260° of geomagnetic longitude (CMO) expanded to 351°(PBQ) in about 48 min. The expansion velocity was 0.03-0.04°/s, or 1.9 km/s at 62°N of geomagnetic latitude. The dipolarization region expanding to the east was accompanied by a bipolar event at the leading edge of the expansion in latitudes equatorward of the westward electrojet (WEJ). In the midnight sector at the onset meridian, the Magnetospheric Plasma Analyzer (MAP) on board geosynchronous satellite L9 measured electrons and ions between 10 eV and 40 keV. We conclude from the satellite observations that this dipolarization was characterized by the evolution of temperature anisotropies, an increase of the electron and ion temperatures, and a rapid change in the symmetry axis of the temperature tensor. The field line dipolarization and its longitudinal expansion were interpreted in terms of the slow MHD mode triggered by the current disruption. We propose a new magnetosphere-ionosphere coupling (MI-coupling) mechanism based on the scenario that transmitted westward electric fields from the magnetosphere in association with expanding dipolarization produced electrostatic potential (negative) in the ionosphere through differences in the mobility of collisional ions and collisionless electrons. The field-aligned currents that emerged from the negative potential region are arranged in a concentric pattern around the negative potential region, upward toward the center and downward on the peripheral.

  13. Design and Optimization of Fast Switching Valves for Large Scale Digital Hydraulic Motors

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck

    The present thesis is on the design, analysis and optimization of fast switching valves for digital hydraulic motors with high power ratings. The need for such high power motors origins in the potential use of hydrostatic transmissions in wind turbine drive trains, as digital hydraulic machines...... have been shown to improve the overall efficiency and efficient operation range compared to traditional hydraulic machines. Digital hydraulic motors uses electronically controlled independent seat valves connected to the pressure chambers, which must be fast acting and exhibit low pressure losses...... to enable efficient operation. These valves are complex components to design, as multiple design aspects are present in these integrated valve units, with conflicting objectives and interdependencies. A preliminary study on a small scale single-cylinder digital hydraulic pump has initially been conducted...

  14. Optimization of geometry of annular seat valves suitable for Digital Displacement fluid power pumps/motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    work an annular seat valve suitable for use in Digital Displacement units is considered, and the ring geometry is optimized using finite element analysis including non-linear material behaviour, contact elements and fluid pressure penetrating load, closely reflecting the actual load of the seat valve......Digital Displacement Fluid Power is an upcoming technology setting new standards for the achievable efficiency of fluid power pumps and motors. The core element of the Digital Displacement technology is high performance electronically controlled seat valves, which must exhibit very low flow...... pressure loss and switching times within a few milliseconds to enable high efficiency operation. These valves are mechatronic components and special attention to both the mechanical, electromagnetic, fluid dynamical and control system design must be paid to ensure the needed performance. In the present...

  15. Prognostic implications of left ventricular asymmetry in patients with asymptomatic aortic valve stenosis

    DEFF Research Database (Denmark)

    Sigvardsen, Per Ejlstrup; Larsen, Linnea Hornbech; Carstensen, Helle Gervig

    2017-01-01

    Aims: Left ventricular (LV) regional hypertrophy in the form of LV asymmetry is a common finding in patients with aortic valve stenosis. The aim of this study was to test the hypothesis that LV asymmetry predicts future symptomatic status and indication for aortic valve replacement (AVR) in patie......Aims: Left ventricular (LV) regional hypertrophy in the form of LV asymmetry is a common finding in patients with aortic valve stenosis. The aim of this study was to test the hypothesis that LV asymmetry predicts future symptomatic status and indication for aortic valve replacement (AVR...... by multi-detector computed tomography according to previous definitions. Follow-up was conducted using electronic health records. Event-free survival was assessed using Cox proportional hazards models. Patients were followed for a median of 2.2 years (interquartile range 1.6-3.6). Indication for AVR...

  16. Use of thermodynamics and expansion in parts and machines; Utilisation de la thermodynamique de la detente dans les organes et les machines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This conference day was organized by the `thermodynamics` section of the French association of thermal engineers. This book of proceedings contains 11 papers entitled: `introduction talk`; `use of thermodynamics during expansion in valves in order to improve their behaviour`; `influence of the presence of impurities on the vapour condensation process during expansion inside a nozzle`; `excitations generated by flows during expansions`; `relief valves for refrigerating machineries`; `the influence of pressure losses in distribution systems over thermodynamic performances of the cryogenic pressure reducer and pneumatic engines`; `analysis of energy losses in turbine blades`; `humid vapor expansion in turbines`; `expansion of high temperature combustion gases in a turbine: influence of chemical reactivity`; `high expansion rate turbines`; `contribution of new calculation methods`. (J.S.)

  17. Subclinical leaflet thickening and stent frame geometry in self-expanding transcatheter heart valves

    DEFF Research Database (Denmark)

    Fuchs, Andreas; De Backer, Ole; Brooks, Matthew

    2017-01-01

    AIMS: This study aimed to assess the potential relationship between subclinical leaflet thickening and stent frame geometry in patients who underwent aortic valve replacement with a self-expanding transcatheter heart valve (THV). METHODS AND RESULTS: Seventy-five patients with a self-expanding THV...... were studied with 4D-computed tomography and analysed for leaflet thickening. There was no difference in THV size, overall THV expansion, eccentricity or implantation depth between patients with and those without leaflet thickening. Moderate-to-severe regional THV underexpansion (≤90°) more frequently...... occurred at the non-coronary and right coronary cusps with a significantly higher incidence of leaflet thickening than in cases of full regional THV expansion (24% vs. 3%, p

  18. A New Hemostasis Valve for Neuroendovascular Procedures

    Science.gov (United States)

    Namba, K.; Song, J.K.; Niimi, Y.; Heran, N.S.; Berenstein, A.

    2007-01-01

    Summary A hemostasis valve is routinely used in neuroendovascular procedures to decrease the risk of thromboembolism1,2. Recently, a new hemostasis valve that is designed to minimize blood loss has been introduced. We report our initial experience in using this new hemostasis valve. In neuroendovascular procedures, a hemostasis valve is commonly used for continuous irrigation of guide and microcatheters to decrease the risk of thromboembolism1,2,3. A conventional hemostasis valve has a rotating seal at the end, which is turned open or closed each time a wire or microcatheter/guidewire is introduced or extracted. Often this results in significant back bleeding. When a rotating seal is adjusted suboptimally during a wire or microcatheter manipulation, leakage of pressurized saline from the end of a hemostasis valve results in stagnation of blood within a guiding catheter, which becomes a potential source of emboli during a procedure. The Guardian Haemostasis Valve (Zerusa Limited, Galway, Ireland) is a new hemostasis valve that is designed to minimize blood loss during interventional procedures by minimizing the opening time of the valve during wire or microcatheter insertion. A continuous sealing mechanism during wire or microcatheter positioning minimizes blood loss and stagnation of blood within the guide catheter. We report our initial experience with the Guardian hemostasis valve. PMID:20566129

  19. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    Science.gov (United States)

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  20. Contemporary outcomes in reoperative mitral valve surgery.

    Science.gov (United States)

    Mehaffey, Hunter J; Hawkins, Robert B; Schubert, Sarah; Fonner, Clifford; Yarboro, Leora T; Quader, Mohammed; Speir, Alan; Rich, Jeff; Kron, Irving L; Ailawadi, Gorav

    2017-10-05

    Data suggest that redo mitral valve surgery is being performed in increasing numbers, possibly with superior results according to single-centre studies. The purpose of this study is to describe outcomes of redo mitral valve surgery and identify risk-adjusted predictors of poor outcomes. All (11 973) open mitral valve cases were evaluated (2002-2016) from a regional Society of Thoracic Surgery (STS) database. Patients were stratified by primary versus redo mitral valve surgery. Mixed effects logistic regression models including hospital as a random effect were used to identify risk factors for patients undergoing redo mitral valve surgery. Of all mitral valve cases, 1096 (9.7%) had a previous mitral operation. Redo patients had higher rates of valve replacement and preoperative comorbidities resulting in more complications, operative mortalities (11.1%vs6.5%, pmitral valve surgery increased 10% per year and the observed-to-expected ratios (O/E) for operative mortality in redo mitral surgery improved from 1.44 early in the study period to 0.72 in the most recent era. Redo mitral valve surgery accounts for approximately 10% of mitral valve operations and is associated with increased risk and resource utilisation. However, as the volume of redo mitral surgery increases, outcomes have dramatically improved and are now better than predicted. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  2. Bioprosthetic heart valves of the future.

    Science.gov (United States)

    Manji, Rizwan A; Ekser, Burcin; Menkis, Alan H; Cooper, David K C

    2014-01-01

    Glutaraldehyde-fixed bioprosthetic heart valves (GBHVs), derived from pigs or cows, undergo structural valve deterioration (SVD) over time, with calcification and eventual failure. It is generally accepted that SVD is due to chemical processes between glutaraldehyde and free calcium ions in the blood. Valve companies have made significant progress in decreasing SVD from calcification through various valve chemical treatments. However, there are still groups of patients (e.g., children and young adults) that have accelerated SVD of GBHV. Unfortunately, these patients are not ideal patients for valve replacement with mechanical heart valve prostheses as they are at high long-term risk from complications of the mandatory anticoagulation that is required. Thus, there is no "ideal" heart valve replacement for children and young adults. GBHVs represent a form of xenotransplantation, and there is increasing evidence that SVD seen in these valves is at least in part associated with xenograft rejection. We review the evidence that suggests that xenograft rejection of GBHVs is occurring, and that calcification of the valve may be related to this rejection. Furthermore, we review recent research into the transplantation of live porcine organs in non-human primates that may be applicable to GBHVs and consider the potential use of genetically modified pigs as sources of bioprosthetic heart valves. © 2014 John Wiley & Sons A/S.

  3. Low power valve actuation using trans-permanent magnetics

    Science.gov (United States)

    Duval, Luis Denit

    The subject of magnetic actuators is very broad, and encompasses a wide range of technologies, magnetic circuit topologies, and performance characteristics for an ever-increasing spectrum of applications. As a consequence of recent advances in soft and hard magnetic materials and developments in power electronics, microprocessors and digital control strategies, and the continuing demand for higher performance motion control systems, there appears to be more research and development activity in magnetic actuators for applications spanning all market sectors than at any time. In this dissertation, a rational approach for switching the states of permanent magnets through an on-board magnetization process is presented. The resulting dynamic systems are referred to as trans-permanent magnetic systems (T-PM). The first part of this research focuses on the governing equations needed for the analysis of T-PM systems. Their feasibility is demonstrated experimentally. In doing so, a method that has the potential of leading to new ultra-low power designs for electromechanical devices is introduced. In the second part of this research, the aforementioned developments in T-PM are applied to the problem of low power valves. Whereas alternate approaches to low power valve control may utilize latching mechanisms to maintain valve position during inactive periods, an approach that eliminates latching mechanisms is presented. Instead, the principles of T-PM are employed to switch the states of permanent magnets; the used of permanent magnets instead of electromagnets eliminates power consumption during inactive periods, thereby reducing power consumption to ultra-low levels. The magnets in a T-PM actuator are configured in a stack. The relationships between the strength and number of magnets in the stack and the stroke and resolution of the actuator are developed. This dissertation reports on the design and testing of a prototype valve actuator that uses a stack pf T-PM with

  4. Wake Expansion Models

    DEFF Research Database (Denmark)

    Branlard, Emmanuel Simon Pierre

    2017-01-01

    Different models of wake expansion are presented in this chapter: the 1D momentum theory model, the cylinder analog model and Theodorsen’s model. Far wake models such as the ones from Frandsen or Rathmann or only briefly mentioned. The different models are compared to each other. Results from thi...... this chapter are used in Chap. 16 to link near-wake and far-wake parameters and in Chap. 20 to study the influence of expansion on tip-losses....

  5. Nuclear expansion with excitation

    Energy Technology Data Exchange (ETDEWEB)

    De, J.N. [Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata 700064 (India); Departament d' Estructura i Constituents de la Materia, Facultat de Fisica, Universitat de Barcelona, Diagonal 647, 08028 Barcelona (Spain); Samaddar, S.K. [Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata 700064 (India); Vinas, X. [Departament d' Estructura i Constituents de la Materia, Facultat de Fisica, Universitat de Barcelona, Diagonal 647, 08028 Barcelona (Spain); Centelles, M. [Departament d' Estructura i Constituents de la Materia, Facultat de Fisica, Universitat de Barcelona, Diagonal 647, 08028 Barcelona (Spain)]. E-mail: mario@ecm.ub.es

    2006-07-06

    The expansion of an isolated hot spherical nucleus with excitation energy and its caloric curve are studied in a thermodynamic model with the SkM{sup *} force as the nuclear effective two-body interaction. The calted results are shown to compare well with the recent experimental data from energetic nuclear collisions. The fluctuations in temperature and density are also studied. They are seen to build up very rapidly beyond an excitation energy of {approx}9 MeV/u. Volume-conserving quadrupole deformation in addition to expansion indicates, however, nuclear disassembly above an excitation energy of {approx}4 MeV/u.

  6. Uniform gradient expansions

    Directory of Open Access Journals (Sweden)

    Massimo Giovannini

    2015-06-01

    Full Text Available Cosmological singularities are often discussed by means of a gradient expansion that can also describe, during a quasi-de Sitter phase, the progressive suppression of curvature inhomogeneities. While the inflationary event horizon is being formed the two mentioned regimes coexist and a uniform expansion can be conceived and applied to the evolution of spatial gradients across the protoinflationary boundary. It is argued that conventional arguments addressing the preinflationary initial conditions are necessary but generally not sufficient to guarantee a homogeneous onset of the conventional inflationary stage.

  7. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  8. Mechanical valves in the pulmonary position : An international retrospective analysis

    NARCIS (Netherlands)

    Pragt, Hanna; van Melle, Joost P.; Javadikasgari, Hoda; Seo, Dong Man; Stulak, John M.; Knez, Igor; Hoerer, Juergen; Munoz-Guijosa, Christian; Dehaki, Mahyar G.; Shin, Hong Ju; Dearani, Joseph A.; Dehaki, Maziar G.; Pieper, Petronella G.; Eulenburg, Christine; Dos, Laura; Ebels, Tjark

    2017-01-01

    Objective: Life expectancy of patients with congenital heart disease has improved over the past decades, increasing the need for a durable pulmonary prosthetic valve. Biological valves in various forms have become the valve of choice for pulmonary valve replacement (PVR), but structural valve

  9. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  10. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  11. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  12. AUTO-EXPANSIVE FLOW

    Science.gov (United States)

    Physics suggests that the interplay of momentum, continuity, and geometry in outward radial flow must produce density and concomitant pressure reductions. In other words, this flow is intrinsically auto-expansive. It has been proposed that this process is the key to understanding...

  13. Rethinking expansive learning

    DEFF Research Database (Denmark)

    Kolbæk, Ditte; Lundh Snis, Ulrika

    discussion forum on Google groups, they created new ways of reflecting and learning. We used netnography to select qualitative postings from the online community and expansive learning concepts for data analysis. The findings show how students changed practices of organisational learning...

  14. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  15. 3D Printed Multimaterial Microfluidic Valve.

    Science.gov (United States)

    Keating, Steven J; Gariboldi, Maria Isabella; Patrick, William G; Sharma, Sunanda; Kong, David S; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  16. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), inclu...... population. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173....

  17. Elimination of alpha-gal xenoreactive epitope: alpha-galactosidase treatment of porcine heart valves.

    Science.gov (United States)

    Choi, Sun-Young; Jeong, Hee-Jin; Lim, Hong-Gook; Park, Seong-Sik; Kim, Soo-Hwan; Kim, Yong Jin

    2012-05-01

    Porcine heart valves are among the most widely used tissue valves in clinical heart valve implantation. However, immunologic responses have been implicated as potential causes of the limited durability of xenograft heart valves. The study aim was to determine the effectiveness of alpha-galactosidase treatment used to degrade the major xenoreactive antigens found in xenograft heart valves. Fresh porcine heart valves and pericardium treated with alpha-galactosidase were studied to evaluate the xenoreactive galactose (alpha1,3) galactose (alpha-gal) antigen. Removal of the alpha-gal epitope from the porcine heart valve was monitored via 3,3'-diaminobenzidine staining intensity, while the removal of alpha-gal from N-glycans on porcine heart valves treated with recombinant alpha-galactosidase was determined either qualitatively or quantitatively by mass fingerprinting using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The porcine pericardium was used for monitoring the change in mechanical properties after alpha-galactosidase treatment. In addition, the biomechanical modification property of collagen fiber rearrangement on tissue was assessed using transmission electron microscopy (TEM). Following a 24-h incubation at pH 7.2, 4 degrees C, employing 0.1 U/ml of Bacteroides thetaiotaomicron-derived recombinant alpha-galactosidase, the enzyme effectively removed the alpha-gal epitopes expressed on porcine heart valves. The identification type of alpha-gal N-glycan on fresh aortic valve, aortic wall, pulmonary valve, and pulmonary wall was 7.1%, 10.3%, 6% and 8%, respectively. In the presence of alpha-galactosidase treatment, alpha-gal-containing N-glycans were converted into alpha-gal-negative N-glycans. Likewise, alpha-gal-containing N-glycans were not detected when MALDI-TOF MS quantitative analysis was used. Furthermore, no significant difference was observed in the mechanical properties and findings from TEM in alpha

  18. Impact of percutaneous pulmonary valve implantation procedural steps on leaflets histology and mechanical behaviour: An in vitro study.

    Science.gov (United States)

    Jalal, Zakaria; Galmiche, Louise; Beloin, Christophe; Boudjemline, Younes

    2016-01-01

    Percutaneous pulmonary valve implantation (PPVI) using the bovine jugular vein Melody(®) valve (Medtronic Inc., Minneapolis, MN, USA) is safe and effective. However, post-procedural complications have been reported, the reasons for which are unclear. To assess the impact of PPVI procedural steps on valvular histology and leaflet mechanical behaviour. Three different valved stents (the Melody(®) valve and two homemade stents with bovine and porcine pericardium) were tested in vitro under four conditions: (1) control group; (2) crimping; (3) crimping plus inflation of low-pressure balloon; (4) condition III plus post-dilatation (high-pressure balloon). For each condition, valvular leaflets (and a venous wall sample for Melody(®) stents) were taken for histological analysis and mechanical uniaxial testing of the valve leaflets. Among the Melody(®) valves, the incidence of transverse fractures was significantly higher in traumatized samples compared with the control group (P<0.05), whereas the incidence and depth of transverse fractures were not statistically different between the four conditions for bovine and porcine pericardial leaflets. No significant modification of the mechanical behaviour of in vitro traumatized Melody(®) valvular leaflets was observed. Bovine and porcine pericardia became more elastic and less resilient after balloon expansion and post-dilatation (conditions III and IV), with a significant decrease in elastic modulus and stress at rupture. Valved stent implantation procedural steps induced histological lesions on Melody(®) valve leaflets. Conversely, bovine and porcine pericardial valved stents were not histologically altered by in vitro manipulations, although their mechanical properties were significantly modified. These data could explain some of the long-term complications observed with these substitutes. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Simplified surgical-hybrid Melody® valve implantation for paediatric mitral valve disease

    OpenAIRE

    Hofmann, Michael; Dave, Hitendu; Hübler, Michael; Kretschmar, Oliver

    2017-01-01

    Children suffering from left atrioventricular valve (LAVV) disease not amenable to repair represent a significant challenge. The results of surgical reconstruction are not optimal. Valve replacement as an alternative is associated with poor results. The surgical-hybrid approach with implantation of a stented biological valve (bovine jugular vein graft, Melody® valve) seems to represent a new therapeutic option. Here we demonstrate our case, the consideration and the approach to extreme clinic...

  20. Propellant actuated nuclear reactor steam depressurization valve

    Science.gov (United States)

    Ehrke, Alan C.; Knepp, John B.; Skoda, George I.

    1992-01-01

    A nuclear fission reactor combined with a propellant actuated depressurization and/or water injection valve is disclosed. The depressurization valve releases pressure from a water cooled, steam producing nuclear reactor when required to insure the safety of the reactor. Depressurization of the reactor pressure vessel enables gravity feeding of supplementary coolant water through the water injection valve to the reactor pressure vessel to prevent damage to the fuel core.

  1. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  2. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  3. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  4. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  5. Percutaneous approaches to mitral valve disease

    National Research Council Canada - National Science Library

    Fassa, A-A; Himbert, D; Brochet, E; Bouleti, C; Vahanian, A

    2015-01-01

    Percutaneous approaches to mitral valve disease consist in modifications of existing surgical techniques, aiming to replicate the favourable outcomes of surgery, with less procedure-related risk, due...

  6. Hammock mitral valve: A rare case report

    Directory of Open Access Journals (Sweden)

    Veeresh F. Manvi

    2014-01-01

    Full Text Available Congenital mitral stenosis is a relatively rare disorder comprising 0.2% of all congenital heart defects. Hammock mitral valve producing severe mitral stenosis is a rare variant of congenital mitral stenosis. We report a 2-year-old boy who had hammock mitral valve producing severe mitral stenosis with severe pulmonary artery hypertension. He underwent successful surgical repair. Post-surgery, the mitral valve opening was adequate without residual stenosis or regurgitation. Pulmonary artery pressure had normalized. Follow-up data showed he had significant clinical and echocardiography improvement. This is the first reported case of successful surgical repair done for hammock mitral valve from our institute.

  7. Stentless aortic valve replacement: an update

    Directory of Open Access Journals (Sweden)

    Kobayashi J

    2011-06-01

    Full Text Available Junjiro KobayashiDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, Osaka, JapanAbstract: Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient–prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose of this review is to provide a current overview of stentless valves in the aortic position. Retrospective and prospective randomized controlled studies showed similar operative mortality and morbidity in stented and stentless aortic valve replacement (AVR, though stentless AVR required longer cross-clamp and cardiopulmonary bypass time. Several cohort studies showed improved survival after stentless AVR, probably due to better hemodynamic performance and earlier left ventricular (LV mass regression compared with stented AVR. However, there was a bias of operation age and nonrandomization. A randomized trial supported an improved 8-year survival of patients with the Freestyle or Toronto valves compared with Carpentier–Edwards porcine valves. On the contrary, another randomized study did not show improved clinical outcomes up to 12 years. Freedom from reoperation at 12 years in Toronto stentless porcine valves ranged from 69% to 75%, which is much lower than for Carpentier–Edwards Perimount valves. Cusp tear with consequent aortic regurgitation was the most common cause of structural valve deterioration. Cryolife O'Brien valves also have shorter durability compared with stent valves. Actuarial freedom from reoperation was 44% at 10 years. Early prosthetic valve failure was also reported in patients who underwent root replacement with Shelhigh stentless composite grafts. There was no level I or IIa evidence of more effective orifice

  8. Pump arrangement Comprising a Savety Valve

    OpenAIRE

    Richter, M.; Kruckow, J.

    2009-01-01

    A pump arrangement comprises a pump (20) having a pump inlet (22) and a pump outlet (24), which are designed to pump a fluid from the pump inlet to the pump outlet, and it further comprises a safety valve (40), which is disposed between the pump outlet (24) and an outlet (48) of the pump arrangement and comprises a valve set (42) and a valve cover (44). The valve seat, the pump outlet, and the pump inlet are structured in a first surface of a first single-piece part (14) of the pump arrangeme...

  9. Fracturing a dysfunctional Edwards Perimount bioprosthetic valve to facilitate percutaneous valve-in-valve placement of SAPIEN 3 valve with modified delivery system.

    Science.gov (United States)

    Shahanavaz, Shabana; Rockefeller, Toby; Nicolas, Ramzi; Balzer, David

    2017-10-10

    Pulmonary valve replacement via surgical implantation of a bioprosthetic valve (BPV) is a well-established treatment for patients with dysfunctional RV outflow tracts. BPVs are prone to structural deterioration, and will eventually require replacement. Recently, percutaneous valve-in-valve (VIV) placement of transcatheter valves has established itself as a safe and effective alternative to surgical revision. Unfortunately, VIV therapy is inherently limited by the inner diameter of the BPV, which restricts the number of eligible patients. Other centers have reported on the feasibility of cracking certain BPVs with ultra high-pressure balloons in bench testing. We now report cracking an Edwards Perimount BPV in the pulmonary position to facilitate VIV placement of an Edwards SAPIEN 3. The ability to crack the Perimount valve allowed placement of a larger valve than previously considered and minimized the final valve gradient. In an effort to avoid the morbidity and mortality of surgical pulmonary valve replacement, this new strategy will expand the number of patients eligible for percutaneous VIV therapy. © 2017 Wiley Periodicals, Inc.

  10. Aortic Calcification: An Early Sign of Heart Valve Problems?

    Science.gov (United States)

    ... the aortic valve — a condition called aortic valve stenosis. Aortic valve calcification may be an early sign ... have any other heart disease symptoms. Calcification and stenosis generally affects people older than age 65. When ...

  11. 40 CFR 63.175 - Quality improvement program for valves.

    Science.gov (United States)

    2010-07-01

    ... (e.g., ball, gate, check); valve manufacturer; valve design (e.g., external stem or actuating... categories, or classes, of valves as needed to distinguish among operating conditions and services associated...

  12. Ionic/Electronic Conductivity, Thermal/Chemical Expansion and Oxygen Permeation in Pr and Gd Co-Doped Ceria PrxGd0.1Ce0.9-xO1.95

    DEFF Research Database (Denmark)

    Cheng, Shiyang; Chatzichristodoulou, Christodoulos; Søgaard, Martin

    2017-01-01

    Pr. A series of compositions of PrxGd0.1Ce0.9-xO1.95-δ (x = 0, 0.02, 0.05, 0.08, 0.15, 0.25, 0.3 and 0.4) was prepared by solid state reaction. X-ray powder diffraction (XPD) indicates that Pr is completely dissolved in the fluorite structure up to 40 at.%. Pronounced nonlinear thermal expansion...... behavior was observed as a function of temperature, due to the simultaneous contributions of both thermal and chemical expansion. The electronic and ionic conductivities were measured as a function of temperature and oxygen partial pressure. Within the range from 10 to 15 at.% Pr, a drastic drop...

  13. IKEA's International Expansion

    OpenAIRE

    Harapiak, Clayton

    2013-01-01

    This case concerns a global retailing firm that is dealing with strategic management and marketing issues. Applying a scenario of international expansion, this case provides a thorough analysis of the current business environment for IKEA. Utilizing a variety of methods (e.g. SWOT, PESTLE, McKinsey Matrix) the overall objective is to provide students with the opportunity to apply their research skills and knowledge regarding a highly competitive industry to develop strategic marketing strateg...

  14. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  15. Character expansion of matrix integrals

    OpenAIRE

    van de Leur, J. W.; Orlov, A. Yu.

    2016-01-01

    We consider character expansion of tau functions and multiple integrals in characters of orhtogonal and symplectic groups. In particular we consider character expansions of integrals over orthogonal and over symplectic matrices.

  16. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    -annular mechanical prostheses (CarboMedics, Inc., Arvada, CO, USA) at two institutions. Size frequency distribution was compared to published series, and to the manufacturer's US registry. The ventriculoaortic junction (VAJ) size was available in 234 patients, and compared to the size of the Top Hat valve implanted......BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...... is less than that of a normal valve. It is suggested that the ability to implant Top Hat valves having greater size, relative to standard intra-annular valves, may currently be under-utilized. Further, there has been some concern that Top Hat implantation can cause obstruction of the coronary ostia...

  17. The Heimlich Valve for Pleural Cavity Drainage

    African Journals Online (AJOL)

    The valve drains into a plastic bag that can be held at any level, allowing the patient to be ambulatory by carrying the bag. The construction and function of the valve is easily understood by medical and nursing staff. It is pre sterilized, stored in a sterile package, and readily utilized on emergency vehicles and in the operating.

  18. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  19. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    She delivered a normal baby uneventfully in follow up at full term of pregnancy with no complications. Fibrinolytic therapy for mechanical valve thrombosis is a reasonable alternative to surgery in first trimester of pregnancy. KEY WORDS: Prosthetic valve thrombosis; Echocardiography; Streptokinase;. Thrombolysis; Fetus.

  20. Sealing a Loosely Fitting Valve Assembly

    Science.gov (United States)

    Goff, L.; Tellier, G.

    1986-01-01

    Double-ring seal avoids expense of remachining or redesigning valve parts. Mating fittings on valve sealed by pair of rings - one O-ring and backup ring. Backup ring fills relatively large gap between parts. Prevents softer O-ring from being pushed into and through gap.

  1. High Temperature Resistant Exhaust Valve Spindle

    DEFF Research Database (Denmark)

    Bihlet, Uffe Ditlev

    of the engine, new high temperature alloys are required for a specific engine component, the exhaust valve spindle. Two alloys are used for an exhaust valve spindle; one for the bottom of the spindle, and one for the spindle seat. Being placed in the exhaust gas stream, combustion products such as V2O5 and Na2...

  2. Mitral valve disease--morphology and mechanisms.

    Science.gov (United States)

    Levine, Robert A; Hagége, Albert A; Judge, Daniel P; Padala, Muralidhar; Dal-Bianco, Jacob P; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H; Clusel, Catherine; Delling, Francesca N; Dietz, Harry C; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D; Jensen, Morten O; Jeunemaitre, Xavier P; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R; Mérot, Jean; Messas, Emmanuel; Milan, David P; Neri, Tui; Norris, Russell A; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A; Song, Jae-Kwan; Yacoub, Magdi H

    2015-12-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.

  3. Mitral valve disease—morphology and mechanisms

    Science.gov (United States)

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  4. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    , most of these transcatheter mitral valve interventions are still in their early clinical or preclinical development phase. Challenges arising from the complex anatomy of the mitral valve and the interplay of the mitral apparatus with the left ventricle (LV) have contributed to a more difficult...

  5. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    system, most of these transcatheter mitral valve interventions are still in their early clinical or preclinical development phase. Challenges arising from the complex anatomy of the mitral valve and the interplay of the mitral apparatus with the left ventricle (LV) have contributed to a more difficult...

  6. Device at valves. Anordning vid ventiler

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, M.; Hedlund, P.O.

    1990-07-02

    The invention is intended to be utilized in pipes and at valves where there are risks for accumulation of oxyhydrogen gas. In or at the pipe/valve is located a body of recombining material such as platinum or other platinum metals or its alloys in order to recombine oxyhydrogen gas. (L.F.).

  7. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...

  8. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  9. Heart Valve Disease among Patients with Hyperprolactinaemia

    DEFF Research Database (Denmark)

    Steffensen, Charlotte; Maegbaek, Merete Lund; Laurberg, Peter

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  10. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature. © The Author(s) 2014.

  11. Multidisciplinary optimization of a butterfly valve.

    Science.gov (United States)

    Song, Xue Guan; Wang, Lin; Baek, Seok Heum; Park, Young Chul

    2009-07-01

    A butterfly valve is a type of flow control device, typically used to regulate fluid flow. This paper proposes a new process to meet desired needs in valve design that is characterized by the complex configuration. First, the need is identified according to the valve user/company, and then the problem is defined with a characteristic function. Second, the initial model of valve is made, and then the initial analysis including fluid and/or structural analysis is carried out to predict the fluid and/or structural performance of the valve. Third, the optimization in the form of mathematical functions, which considers single or multiple objective and/or discipline, is handled. This part includes the design of computer experiment, approximation technique, topology optimization and sizing optimization. Finally, the validation experiment is conducted based on the optimum result to verify the accuracy of the optimization. An example is provided to confirm the availability of the process proposed here.

  12. The Leipzig experience with robotic valve surgery.

    Science.gov (United States)

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  13. Airbag vent valve and system

    Science.gov (United States)

    Peterson, Leslie D. (Inventor); Zimmermann, Richard E. (Inventor)

    2001-01-01

    An energy absorbing airbag system includes one or more vent valve assemblies for controlling the release of airbag inflation gases to maintain inflation gas pressure within an airbag at a substantially constant pressure during a ride-down of an energy absorbing event. Each vent valve assembly includes a cantilever spring that is flat in an unstressed condition and that has a free end portion. The cantilever spring is secured to an exterior surface of the airbag housing and flexed to cause the second free end portion of the cantilever spring to be pressed, with a preset force, against a vent port or a closure covering the vent port to seal the vent port until inflation gas pressure within the airbag reaches a preselected value determined by the preset force whereupon the free end portion of the cantilever spring is lifted from the vent port by the inflation gases within the airbag to vent the inflation gases from within the airbag. The resilience of the cantilever spring maintains a substantially constant pressure within the airbag during a ride-down portion of an energy absorbing event by causing the cantilever spring to vent gases through the vent port whenever the pressure of the inflation gases reaches the preselected value and by causing the cantilever spring to close the vent port whenever the pressure of the inflation gases falls below the preselected value.

  14. Study on decellularized porcine aortic valve/poly (3-hydroxybutyrate-co-3-hydroxyhexanoate) hybrid heart valve in sheep model.

    Science.gov (United States)

    Wu, Song; Liu, Ying-Long; Cui, Bin; Qu, Xiang-Hua; Chen, Guo-Qiang

    2007-09-01

    To overcome shortcomings of current heart valve prostheses, novel hybrid valves were fabricated from decellularized porcine aortic valves coated with poly (3-hydroxybutyrate-co-3-hydroxyhexanoate [PHBHHx]). In the mechanical test in vitro, the biomechanical performance of hybrid valve was investigated. In an in vivo study, hybrid valve conduits were implanted in pulmonary position in sheep without cardiopulmonary bypass. Uncoated grafts were used as control. The valves were explanted and examined histologically and biochemically 16 weeks after surgery. The hybrid valve conduits maintained original shapes, were covered by a confluent layer of cells, and had less calcification than uncoated control. The mechanical test in vitro revealed that PHBHHx coating improved tensile strength. The results in vivo indicated that PHBHHx coating reduced calcification and promoted the repopulation of hybrid valve with the recipient's cells resembling native valve tissue. The hybrid valve may provide superior valve replacement with current techniques.

  15. Magneto-resistive and spin valve heads fundamentals and applications

    CERN Document Server

    Mallinson, John C

    2002-01-01

    This book is aims to be a comprehensive source on the physics and engineering of magneto-resistive heads. Most of the material is presented in a nonmathematical manner to make it more digestible for researchers, students, developers, and engineers.In addition to revising and updating material available in the first edition, Mallinson has added nine new chapters dealing with various aspects concerning spin valves, the electron spin tunneling effect, the electrostatic discharge effects, read amplifiers, and signal-to-noise ratios, making this a completely up-to-date reference.Th

  16. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    Science.gov (United States)

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  17. 3D Printed Trileaflet Valve Conduits Using Biological Hydrogels and Human Valve Interstitial Cells

    Science.gov (United States)

    Duan, Bin; Kapetanovic, Edi; Hockaday, Laura A.; Butcher, Jonathan T.

    2014-01-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, 3D bioprinting enables deposition of cells and hydrogels into 3D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach is however constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not known how human valve cells respond to these printed environments. In this study, we develop 3D printable formulations of hybrid hydrogels based on methacrylated hyaluronic acid (Me-HA) and methacrylated gelatin (Me-Gel), and utilize them to bioprint heart valve conduits containing encapsulated human aortic valvular interstitial cells (HAVIC). Increasing Me-Gel concentration resulted in lower stiffness and higher viscosity, facilitated cell spreading, and better maintained HAVIC fibroblastic phenotype. Bioprinting accuracy was dependent upon the relative concentrations of Me-Gel and Me-HA, but when optimized enabled the fabrication of a trileaflet valve shape accurate to the original design. HAVIC encapsulated within bioprinted heart valves maintained high viability, and remodeled the initial matrix by depositing collagen and glyosaminoglycans. These findings represent the first rational design of bioprinted trileaflet valve hydrogels that regulate encapsulated human VIC behavior. The use of anatomically accurate living valve scaffolds through bioprinting may accelerate our understanding of physiological valve cell interactions and our progress towards de novo living valve replacements. PMID:24334142

  18. Quadruple valve replacement with mechanical valves: an 11-year follow-up study.

    Science.gov (United States)

    Cao, Yukun; Gu, Chunhu; Sun, Guocheng; Yu, Shiqiang; Wang, Hongbing; Yi, Dinghua

    2012-06-01

    We performed the first quadruple valve replacement with mechanical valves, combined with the correction of complex congenital heart disease on November 17, 1999. We report here the 11-year follow-up study. A 47-year-old man with subacute rheumatic endocarditis, a ventricular septal defect, and an obstruction of the right ventricular outflow tract required replacement of the aortic, mitral, tricuspid, and pulmonary valves; repair of the ventricular septal defect; and relief of the obstruction of the right ventricular outflow tract. The surgery was done on November 17, 1999, after careful systemic preparation of the patient. Warfarin therapy with a target international normalized ratio (INR) range of 1.5 to 2.0 was used. Follow-up included monitoring the INR, recording the incidences of thromboembolic and bleeding events, electrocardiography, radiography, and echocardiography evaluations. The patient's INR was maintained between 1.5 and 2.0. All 4 mechanical prosthetic heart valves worked well. He is in generally good health without any thromboembolic or bleeding complications. Long-term management is challenging for patients who have experienced quadruple valve replacement with mechanical valves; however, promising results could mean that replacement of all 4 heart valves in 1 operation is feasible in patients with quadruple valve disease, and an INR of 1.5 to 2.0 could be appropriate for Chinese patients with undergoing valve replacement with mechanical valves.

  19. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  20. Quantification of calcified particles in human valve tissue reveals asymmetry of calcific aortic valve disease development

    Directory of Open Access Journals (Sweden)

    Katsumi Yabusaki

    2016-11-01

    Full Text Available Recent studies indicated that small calcified particles observable by scanning electron microcopy (SEM may initiate calcification in cardiovascular tissues. We hypothesized that if the calcified particles precede gross calcification observed in calcific aortic valve disease (CAVD, they would exhibit a regional asymmetric distribution associated with CAVD development, which always initiates at the base of aortic valve leaflets adjacent to the aortic outflow in a region known as the fibrosa. Testing this hypothesis required counting the calcified particles in histological sections of aortic valve leaflets. SEM images, however, do not provide high contrast between components within images, making the identification and quantification of particles buried within tissue extracellular matrix difficult. We designed a new unique pattern matching-based technique to allow for flexibility in recognizing particles by creating a gap zone in the detection criteria that decreased the influence of non-particle image clutter in determining whether a particle was identified. We developed this flexible pattern particle labeling (FpPL technique using synthetic test images and human carotid artery tissue sections. A conventional image particle counting method (pre-installed in ImageJ did not properly recognize small calcified particles located in noisy images that include complex extracellular matrix structures, and other commonly used pattern matching methods failed to detect the wide variation in size, shape and brightness exhibited by the particles. Comparative experiments with the ImageJ particle counting method demonstrated that our method detected significantly more p<2*10-7 particles than the conventional method with significantly fewer p<0.0003 false positives and false negatives p<0.0003. We then applied the FpPL technique to CAVD leaflets and showed a significant increase in detected particles in the fibrosa at the base of the leaflets (p<0.0001, supporting

  1. 49 CFR 192.193 - Valve installation in plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve installation in plastic pipe. 192.193... Components § 192.193 Valve installation in plastic pipe. Each valve installed in plastic pipe must be designed so as to protect the plastic material against excessive torsional or shearing loads when the valve...

  2. Towards new therapies for calcific aortic valve disease

    NARCIS (Netherlands)

    Riem Vis, P.W.

    2011-01-01

    Calcific aortic valve disease (CAVD) is characterized by progressive calcification of the aortic valve cusps. The end-stage (stenosis), can lead to heart failure and death. Approximately 2-3% of adults over 65 years of age are thought to suffer from valve stenosis, requiring aortic valve

  3. 46 CFR 56.20-9 - Valve construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve construction. 56.20-9 Section 56.20-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Valves § 56.20-9 Valve construction. (a) Each valve must close with a right-hand (clockwise...

  4. [Clinical analysis of robotic mitral valve repair].

    Science.gov (United States)

    Gao, Chang-Qing; Yang, Ming; Xiao, Cang-Song; Wang, Gang; Wang, Jia-Li; Wu, Yang; Wang, Yao

    2011-07-01

    To determine the safety and efficacy of robotic mitral valve repair using da Vinci S Surgical system. Method From January 2007 to April 2011, over 400 cases of robotic cardiac surgery have been performed, in which 60 patients with isolated mitral valve insufficiency underwent robotic mitral valve repair, including 42 male and 18 female patients with a mean age of (44 ± 13) years (ranging from 14 to 70 years). Forty-eight patients were in NYHA class I-II and 12 patients in class III. Fourteen patients were concomitant with atrial fibrillation. Surgery approach was achieved through 4 right chest ports with femoral perfusion and Chitwood aortic occlusion. Antegrade cold blood cardioplegia was administered directly via chest for myocardial protection. The transesophageal echocardiography was used intraoperatively to estimate the surgical results. All patients had successful valve repair including quadrangular resections, sliding plasties and chordal replacement. There was no conversion to median sternotomy. The mean cardiopulmonary bypass and arrested heart time were (132 ± 30) min and (88 ± 22) min. One patient had hemolysis after operation, and required mitral valve replacement. Echocardiographic follow-up revealed trace to mild regurgitation in 2 patients with a mean of (16 ± 9) months. Robotic mitral valve repair is safe and efficacious in the patients with isolated mitral valve insufficiency.

  5. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  6. Low cost valves motorization using micro controller; Motorizacion de valvulas de bajo coste mediante microcontrolador

    Energy Technology Data Exchange (ETDEWEB)

    Menendez, A.; Leal, M. A.; Dominguez Ademe, G.; Yaglian, E.

    2004-07-01

    This article describes a new solution for valves motorization with the objective to obtain a minimum cost and a minimum size. With it, it is proposed to facilitate the complex applications of automation in the hydraulic sector, with multiple volume and pressure controls, like the one made on Integrated Digital Control of Desalting Water Plants. The design presented here consists basically of an original mechanical connection that allows to use standard market valves and moto-gearboxes and a simplified electronic controller based on a micro controller with an elaborated software that allows to control the mother either in ON/Off (open/close) applications or in incremental applications of Regulation. (Author)

  7. Percutaneous management of prosthetic valve thrombosis.

    Science.gov (United States)

    Hariram, Vuppaladadhiam

    2014-01-01

    Thrombosis of a prosthetic valve is a serious complication in patients with prosthetic heart valves. Thrombolysis is the initial choice of treatment. Patients who do not respond to thrombolysis are subjected to surgery which carries a high risk. We report a case series of 5 patients with prosthetic mitral valve thrombosis who did not respond to thrombolysis and were subjected to percutaneous manipulation of the prosthetic valves successfully and improved. Five patients who were diagnosed to have prosthetic mitral valve thrombosis and failed to respond to a minimum of 36 h of thrombolysis (persistent symptoms with increased gradients, abnormal findings on fluoroscopy),were subjected to percutaneous treatment after receiving proper consent. None of them had a visible thrombus on transthoracic echocardiogram. All patients underwent transseptal puncture following which a 6F JR4 guiding catheter was passed into the left atrium. The valve leaflets were repeatedly hit gently under fluoroscopic guidance till they regained their normal mobility. Mean age was 38.8 years. Average peak and mean gradients prior to the procedure were 38 and 25 and after the procedure were 12 and 6 mm of Hg respectively. All patients had successful recovery of valve motion on fluoroscopy with normalization of gradients and complete resolution of symptoms. None of the patients had any focal neurological deficits, embolic manifestations or bleeding complications. Percutaneous manipulation of prosthetic valves in selected patients with prosthetic valve thrombosis who do not respond to thrombolytic therapy is feasible and can be used as an alternative to surgery. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  8. Transcatheter Aortic Valve Replacement: A Review Article

    Directory of Open Access Journals (Sweden)

    Juan A Siordia

    2016-06-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive procedure and reduce common complications, such as stroke. This review article focuses on the current data on the indications, risks, benefits, and future directions of TAVR. Recently, TAVR has been considered as a standard-of-care procedure. While this technique is used frequently in high-risk surgical candidates, studies have been focusing on the application of this method for younger patients with lower surgical risk. Moreover, several studies have proposed promising results regarding the use of valve-in-valve technique or the procedure in which the valve is placed within a previously implemented bioprosthetic valve. However, ischemic strokes and paravalvular leak remain a matter of debate in these surgeries. New methods and devices have been developed to reduce the incidence of post-procedural stroke. While the third generation of TAVR valves (i.e., Edwards Sapien 3 and Medtronic Evolut R addresses the issue of paravalvular leak structurally, results on their efficacy in reducing the risk of paravalvular leak are yet to be obtained. Furthermore, TAVR enters the field of hybrid methods in the treatment of cardiac issues via both surgical and catheter-based approaches. Finally, while TAVR is primarily performed on cases with aortic stenosis, new valves and methods have been proposed regarding the application of this technique in aortic regurgitation, as well as other aortic pathologies. TAVR is a suitable therapeutic approach for the treatment of aortic stenosis in high-risk patients. Considering the promising results in the current patient population

  9. Optimal Design and Operation for a No-Moving-Parts-Valve (NMPV Micro-Pump with a Diffuser Width of 500 µm

    Directory of Open Access Journals (Sweden)

    Jia-Ming Sun

    2009-05-01

    Full Text Available A no-moving-parts-valve (NMPV with a diffuser width of D = 500 microns was investigated in this study by numerical simulations at Reynolds numbers, ReD, ranging from 20 to 75, and expansion valve angles ranging from 30° < θ1 < 57° and 110° < θ2 < 120°. The D p,i value, 1.02 < D p,i < 1.14, is larger within the proposed range of the expansion valve angles. A flow channel structure with a depth of 500 micron is manufactured using yellow light lithography in this study. From prior analyses and experiments, it is found that piezoelectric films work better at a buzz driving frequency of f < 30Hz and the best operating frequency is at a driving frequency of f = 10Hz because it produces the largest net flow. In addition, the expansion angles θ1 = 30° and θ2 = 120° are the best expansion angles because they produce the largest net flow. These related results are very helpful for the actual design of no-moving-parts-valve micro-pump.

  10. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  11. Sensitivity study of a valve recession model

    OpenAIRE

    Vera-Cardenas, E.E.; Lewis, R; Slatter, T.

    2017-01-01

    The aim of this work was to carry out a sensitivity\\ud analysis of a valve recession model. \\ud For the sensitivity study, the effects of the param\\ud eters on the valve recession mode\\ud l were \\ud investigated, for both, light duty and heavy duty \\ud engines. It was seen that for light duty \\ud engines, the impact component parameters had the gr\\ud eatest effect on valve recession and \\ud for heavy duty engines the sliding wear component p\\ud arameters have an increasing con-\\ud tribution t...

  12. PUMP ARRANGEMENT COMPRISING A SAFETY VALVE ARRANGEMENT

    OpenAIRE

    Richter, Martin; Wackerle, Martin

    2014-01-01

    A pump arrangement comprises a microfluidic pump (20) having a pump inlet (22) and a pump outlet (24), which is configured to pump a fluid from the pump inlet to the pump outlet, wherein the pump inlet (22) and an inlet (46) of the pump arrangement are fluidically connected. The pump arrangement further comprises a safety valve arrangement having first safety valve (40), the first safety valve (40) being arranged between the pump outlet (24) and an outlet (48) of the pump arrangement and comp...

  13. Rotary Valve FY 2016 Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  14. Conical seat shut off valve

    Science.gov (United States)

    Farner, Bruce R. (Inventor)

    2012-01-01

    A valve includes a housing defining a bore having an inlet and extending along a longitudinal axis. A head is attached to the housing and defines a head passage having an outlet. A piston is disposed within the bore and includes a piston passage extending through the piston along the longitudinal axis. The piston is moveable between a closed position in which a sealing end of the piston abuts a seat of the head to close fluid communication through the piston passage and an open position in which the sealing end of the piston is axially spaced along the longitudinal axis from the seat of the head to permit fluid communication through the piston passage between the inlet and the outlet. The housing defines an equalizing chamber in fluid communication with the head passage for damping movement of the piston.

  15. Valve Corporation: Composing Internal Markets

    Directory of Open Access Journals (Sweden)

    Todd R. Zenger

    2015-07-01

    Full Text Available Discussions of the Valve Corporation are always enlightening. The skeptic wonders how much is rhetoric and recruiting ploy and how much is real. Is there clear evidence that this organizational design actually works – that it is efficient in this setting? While revenues per employee are quite remarkable, cause and effect are unclear. Is “boss-less-ness” the cause of high sales per employee or simply the result of high sales per employee, fueled from earlier success? The same question could be asked of Google’s unusual organizational approach. Is Google’s success the result of its extensive autonomy granted to employees, or is its past success the enabling cause of such autonomy? Such questions, of course, are empirically unanswerable here. I therefore set them aside and assume this organizational specimen is efficient – well-suited to its environment – and proceed with further commentary.

  16. Decellularized allogeneic heart valves demonstrate self-regeneration potential after a long-term preclinical evaluation.

    Directory of Open Access Journals (Sweden)

    Laura Iop

    Full Text Available Tissue-engineered heart valves are proposed as novel viable replacements granting longer durability and growth potential. However, they require extensive in vitro cell-conditioning in bioreactor before implantation. Here, the propensity of non-preconditioned decellularized heart valves to spontaneous in body self-regeneration was investigated in a large animal model. Decellularized porcine aortic valves were evaluated for right ventricular outflow tract (RVOT reconstruction in Vietnamese Pigs (n = 11 with 6 (n = 5 and 15 (n = 6 follow-up months. Repositioned native valves (n = 2 for each time were considered as control. Tissue and cell components from explanted valves were investigated by histology, immunohistochemistry, electron microscopy, and gene expression. Most substitutes constantly demonstrated in vivo adequate hemodynamic performances and ex vivo progressive repopulation during the 15 implantation months without signs of calcifications, fibrosis and/or thrombosis, as revealed by histological, immunohistochemical, ultrastructural, metabolic and transcriptomic profiles. Colonizing cells displayed native-like phenotypes and actively synthesized novel extracellular matrix elements, as collagen and elastin fibers. New mature blood vessels, i.e. capillaries and vasa vasorum, were identified in repopulated valves especially in the medial and adventitial tunicae of regenerated arterial walls. Such findings correlated to the up-regulated vascular gene transcription. Neoinnervation hallmarks were appreciated at histological and ultrastructural levels. Macrophage populations with reparative M2 phenotype were highly represented in repopulated valves. Indeed, no aspects of adverse/immune reaction were revealed in immunohistochemical and transcriptomic patterns. Among differentiated elements, several cells were identified expressing typical stem cell markers of embryonic, hematopoietic, neural and mesenchymal lineages in significantly

  17. In vitro balloon dilatation of mitral valve stenosis: the importance of subvalvar involvement as a cause of mitral valve insufficiency

    NARCIS (Netherlands)

    Sadee, A. S.; Becker, A. E.

    1991-01-01

    To investigate the mechanism that increases the orifice area of the mitral valve during balloon dilatation 43 surgically excised intact rheumatic mitral valves were studied. The main pathological features were (a) fibrosis of mitral valve leaflets and commissures (10 valves); (b) fibrosis with

  18. 46 CFR 153.361 - Arrangements for removal of valves from venting systems having multiple relief valves.

    Science.gov (United States)

    2010-10-01

    ... having multiple relief valves. 153.361 Section 153.361 Shipping COAST GUARD, DEPARTMENT OF HOMELAND... removal of valves from venting systems having multiple relief valves. A venting system having multiple... arranged so that cargo vapor will not escape through the opening left after a valve has been removed. ...

  19. Conformal expansions and renormalons

    CERN Document Server

    Gardi, E; Gardi, Einan; Grunberg, Georges

    2001-01-01

    The large-order behaviour of QCD is dominated by renormalons. On the other hand renormalons do not occur in conformal theories, such as the one describing the infrared fixed-point of QCD at small beta_0 (the Banks--Zaks limit). Since the fixed-point has a perturbative realization, all-order perturbative relations exist between the conformal coefficients, which are renormalon-free, and the standard perturbative coefficients, which contain renormalons. Therefore, an explicit cancellation of renormalons should occur in these relations. The absence of renormalons in the conformal limit can thus be seen as a constraint on the structure of the QCD perturbative expansion. We show that the conformal constraint is non-trivial: a generic model for the large-order behaviour violates it. We also analyse a specific example, based on a renormalon-type integral over the two-loop running-coupling, where the required cancellation does occur.

  20. Transcatheter aortic valve implantation with balloonexpandable valve: early experience from China

    Directory of Open Access Journals (Sweden)

    Qingsheng Lu

    2015-08-01

    Full Text Available Abstract Objective: The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is still in the early stages of testing in China, particularly for the balloon-expandable valve procedure. Methods: This was a retrospective study. All patients undergoing transcatheter aortic valve implantation with balloon-expandable system in our hospital between 2011 and 2014 were included. Edwards SAPIEN XT Transcatheter Heart Valve was used. The improvement of valve and heart function was evaluated as well as 30-day mortality and major complications according to the VARC-2 definition. Results: A total of 10 transcatheter aortic valve implantation procedures with the balloon-expandable system were performed in our hospital, of which 9 were transfemoral and 1 was transapical. The median age was 76 years, and the median STS score and Logistic EuroSCORE (% were 8.9 and 16.2. The implantation was successfully conducted in all patients, only 2 patients had mild paravalvular leak. There was no second valve implantation. Moreover, no 30-day mortality or complications was reported. Following the transcatheter aortic valve implantation procedure, the heart and valve functions had improved significantly. During the follow-up period of 3-34 months, one patient died of lung cancer 13 months after the operation. Conclusion: This early experience has provided preliminary evidence for the safety and efficacy of transcatheter aortic valve implantation procedure with the balloon-expandable system in the developing world with an increasing aging population.

  1. Osteoprotegerin inhibits aortic valve calcification and preserves valve function in hypercholesterolemic mice.

    Directory of Open Access Journals (Sweden)

    Robert M Weiss

    Full Text Available There are no rigorously confirmed effective medical therapies for calcific aortic stenosis. Hypercholesterolemic Ldlr (-/- Apob (100/100 mice develop calcific aortic stenosis and valvular cardiomyopathy in old age. Osteoprotegerin (OPG modulates calcification in bone and blood vessels, but its effect on valve calcification and valve function is not known.To determine the impact of pharmacologic treatment with OPG upon aortic valve calcification and valve function in aortic stenosis-prone hypercholesterolemic Ldlr (-/- Apob (100/100 mice.Young Ldlr (-/- Apob (100/100 mice (age 2 months were fed a Western diet and received exogenous OPG or vehicle (N = 12 each 3 times per week, until age 8 months. After echocardiographic evaluation of valve function, the aortic valve was evaluated histologically. Older Ldlr (-/- Apob (100/100 mice were fed a Western diet beginning at age 2 months. OPG or vehicle (N = 12 each was administered from 6 to 12 months of age, followed by echocardiographic evaluation of valve function, followed by histologic evaluation.In Young Ldlr (-/- Apob (100/100 mice, OPG significantly attenuated osteogenic transformation in the aortic valve, but did not affect lipid accumulation. In Older Ldlr (-/- Apob (100/100 mice, OPG attenuated accumulation of the osteoblast-specific matrix protein osteocalcin by ∼80%, and attenuated aortic valve calcification by ∼ 70%. OPG also attenuated impairment of aortic valve function.OPG attenuates pro-calcific processes in the aortic valve, and protects against impairment of aortic valve function in hypercholesterolemic aortic stenosis-prone Ldlr (-/- Apob (100/100 mice.

  2. Computational Fluid Dynamics Analysis of Butterfly Valve Performance Factors

    OpenAIRE

    Del Toro, Adam

    2012-01-01

    Butterfly valves are commonly used in industrial applications to control the internal flow of both compressible and incompressible fluids. A butterfly valve typically consists of a metal disc formed around a central shaft, which acts as its axis of rotation. As the valve's opening angle is increased from 0 degrees (fully closed) to 90 degrees (fully open), fluid is able to more readily flow past the valve. Characterizing a valve's performance factors, such as pressure drop, hydrodynamic torqu...

  3. The 3 S's of the Sapien balloon expandable valve.

    Science.gov (United States)

    Kornowski, Ran

    2016-09-01

    The Sapien 3 (S3) balloon expandable aortic valve equipped with an outer skirt to minimize paravalvular leakage (PVL) was built upon the predecessor Sapien XT (SXT) valve. There is scant comparative data of transcatheter aortic valve replacement using S3 versus SXT valve. The study shows that S3 valve is associated with reduced PVL rate compared with SXT, which is an important clinical advantage. © 2016 Wiley Periodicals, Inc.

  4. Primordial vorticity and gradient expansion

    CERN Document Server

    Giovannini, Massimo

    2012-01-01

    The evolution equations of the vorticities of the electrons, ions and photons in a pre-decoupling plasma are derived, in a fully inhomogeneous geometry, by combining the general relativistic gradient expansion and the drift approximation within the Adler-Misner-Deser decomposition. The vorticity transfer between the different species is discussed in this novel framework and a set of general conservation laws, connecting the vorticities of the three-component plasma with the magnetic field intensity, is derived. After demonstrating that a source of large-scale vorticity resides in the spatial gradients of the geometry and of the electromagnetic sources, the total vorticity is estimated to lowest order in the spatial gradients and by enforcing the validity of the momentum constraint. By acknowledging the current bounds on the tensor to scalar ratio in the (minimal) tensor extension of the $\\Lambda$CDM paradigm the maximal comoving magnetic field induced by the total vorticity turns out to be, at most, of the or...

  5. Large scale steam valve test: Performance testing of large butterfly valves and full scale high flowrate steam testing

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.B.; Robbins, G.E.; Roselius, D.G. [and others

    1995-05-01

    This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned valves operated satisfactorily under high flow conditions.

  6. A Hybrid Double Access for Transcatheter Mitral Valve-In-Valve Implantation.

    Science.gov (United States)

    Pagnotta, Paolo; Mennuni, Marco G; Ferrante, Giuseppe; Ornaghi, Diego; Bragato, Renato; Cappai, Antioco; Presbitero, Patrizia

    2015-06-01

    We present a case of hybrid mitral valve-in valve implantation. The planned transapical approach failed due to the inability to cross the degenerated stenotic mitral bioprosthesis. An alternative strategy was performed: first, an anterograde crossing of mitral stenosis, and then, a guidewire externalization through the apex by using a snare. To our knowledge, this is the first described case of double approach mitral valve-in valve implantation. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. In vitro evaluation of the iValve: a novel hands-free speech valve.

    Science.gov (United States)

    van der Houwen, Eduard B; van Kalkeren, Tjouwke A; Burgerhof, Johannes G M; van der Laan, Bernard F A M; Verkerke, Gijsbertus J

    2011-12-01

    We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.

  8. Full metal jacket: transfemoral aortic valve implantation for regurgitant valve after endovascular aortic repair†.

    Science.gov (United States)

    Tanyeli, Omer; Dereli, Yuksel; Gormus, Niyazi; Duzenli, Mehmet Akif

    2017-07-25

    Transfemoral aortic valve implantation has become an almost routine interventional procedure for severe aortic stenosis in high-risk patients. Over time an increased number of experiences has led to unusual procedures. In this report, we present a successful valve-in-valve transfemoral aortic valve implantation in a patient with aortic regurgitation, who previously had debranching and thoracic endovascular aortic repair operations. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  10. External stress-corrosion cracking of a 1.22-m-diameter type 316 stainless steel air valve

    Science.gov (United States)

    Moore, Thomas J.; Telesman, Jack; Moore, Allan S.; Johnson, Dereck F.; Kuivinen, David E.

    1993-01-01

    An investigation was conducted to determine the cause of the failure of a massive AISI Type 316 stainless steel valve which controlled combustion air to a jet engine test facility. Several through-the-wall cracks were present near welded joints in the valve skirt. The valve had been in outdoor service for 18 years. Samples were taken in the cracked regions for metallographic and chemical analyses. Insulating material and sources of water mist in the vicinity of the failed valve were analyzed for chlorides. A scanning electron microscope was used to determine whether foreign elements were present in a crack. On the basis of the information generated, the failure was characterized as external stress-corrosion cracking. The cracking resulted from a combination of residual tensile stress from welding and the presence of aqueous chlorides. Recommended countermeasures are included.

  11. Morse basis expansion applied to diatomic molecules

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Emanuel F. de, E-mail: eflima@rc.unesp.br [Departamento de Estatística, Matemática Aplicada e Computação, Instituto de Geociências e Ciências Exatas, Universidade Estadual Paulista – UNESP, Rio Claro, São Paulo 13506-900 (Brazil)

    2012-02-20

    This work explores the use of the eigenfunctions of the Morse potential with a infinite barrier at long range to solve the radial Schrödinger equation for diatomic molecules. Analytical formulas are obtained for the kinetic energy operator matrix elements in the Morse basis. The Morse basis expansion is applied to find the vibrational–rotational levels of the sodium molecule in the electronic ground state. -- Highlights: ► The Morse potential basis is invoked to find the rovibrational levels of diatomic molecules. ► Analytical formulas for the kinetic energy operator in the Morse basis are obtained. ► The results of the Morse basis expansion show good agreement with the Fourier Grid technique.

  12. Permissible limit for mandibular expansion.

    Science.gov (United States)

    Motoyoshi, Mitsuru; Shirai, Sawa; Yano, Shinya; Nakanishi, Kotoe; Shimizu, Noriyoshi

    2005-04-01

    In recent years, mandibular expansion has been increasingly performed in conjunction with orthodontic treatment. Lateral tipping of the molars associated with mandibular expansion should, however, be considered, because excessive expansion may result in excessive buccal tooth inclination, which may disturb the occlusal relationship. This study was conducted to quantitatively clarify molar movement during mandibular expansion using the Schwarz appliance to determine the permissible limit of mandibular expansion as a clinical index for inclination movement. Inclinations in the masticatory surface of the first molar and intermolar width were measured before expansion (T1), after expansion (T2), and before edgewise treatment (T3). Lower plaster models from 29 subjects treated with expansion plates were used and compared with models from 11 control subjects with normal occlusion. The average treatment change (T1-T2) in intermolar width was 5.42 mm (standard deviation 1.98), and the average angle of buccal tooth inclination was 10.16 degrees (standard deviation 3.83). No significant correlation was found between age prior to treatment and the treatment period when they were compared with the intermolar width increments and inclination angles. There was a significant positive correlation between retention duration and the amount of expansion. The regression coefficient of the angle of buccal tooth inclination during expansion to the increment of the intermolar width was approximately 0.2. This means that 1 mm of expansion is accompanied by 5 degrees of molar lateral tipping. This coefficient is clinically useful for estimating the permissible limit for mandibular expansion.

  13. Burial Ground Expansion Hydrogeologic Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gaughan , T.F.

    1999-02-26

    Sirrine Environmental Consultants provided technical oversight of the installation of eighteen groundwater monitoring wells and six exploratory borings around the location of the Burial Ground Expansion.

  14. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two low-mass, linear throttling, high-efficiency, leak-proof cryogenic valves of diameters 1/2" and 4" will be built and tested. Based upon cryogenically-proven...

  15. Fluid-solid modeling of lymphatic valves

    Science.gov (United States)

    Caulk, Alexander; Ballard, Matthew; Nepiyushchikh, Zhanna; Dixon, Brandon; Alexeev, Alexander

    2015-11-01

    The lymphatic system performs important physiological functions such as the return of interstitial fluid to the bloodstream to maintain tissue fluid balance, as well as the transport of immune cells in the body. It utilizes contractile lymphatic vessels, which contain valves that open and close to allow flow in only one direction, to directionally pump lymph against a pressure gradient. We develop a fluid-solid model of geometrically representative lymphatic valves. Our model uses a hybrid lattice-Boltzmann lattice spring method to capture fluid-solid interactions with two-way coupling between a viscous fluid and lymphatic valves in a lymphatic vessel. We use this model to investigate the opening and closing of lymphatic valves, and its effect on lymphatic pumping. This helps to broaden our understanding of the fluid dynamics of the lymphatic system.

  16. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two cryogenic flow-control valves of diameters 1/2" and 2" will be built and tested. Based on cryogenically-proven Venturi Off-Set Technology (VOST) they have no...

  17. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  18. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  19. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cryogenic flow-control valve based on Venturi-Offset Technology (VOST) will be designed and modeled. VOST provides precise linear flow control within a...

  20. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Heart Valve Surgery Recovery and Follow Up Updated:Sep 14,2016 ... resources from Adam Pick's blog: Traveling Timeline After Heart Surgery 5 Things to Do While Your Heart Mends ( ...

  1. Posterior Urethral Valves with Severe Unilateral Vesicoureteral ...

    African Journals Online (AJOL)

    2004-08-10

    Aug 10, 2004 ... urinary catheter drainage, with no pedal oedema. There ... In patients with posterior urethral valves (PUV), severe unilateral vesicoureteral reflux (VUR) is one ... evaluation of urinary tract infection (UTI), voiding dysfunction, or ...

  2. Automatic balancing valves in distribution networks today

    Energy Technology Data Exchange (ETDEWEB)

    Golestan, F. [Flow Design, Inc., Dallas, TX (United States)

    1996-12-31

    Automatic flow-limiting (self-actuated) valves have been in the heating, ventilating, and air-conditioning (HVAC) market for some time now. Their principle of operation is based on fluid momentum and Bernoulli`s theorem. Basically, they absorb pressure to keep the flow rate constant. The general operation and their flow characteristics are described in the 1992 ASHRAE Handbook--Systems and Equipment, chapter 43 (ASHRAE 1992). The application and interaction of these valves with other system components, when installed in hydronic distribution networks, are outlined in this presentation. A simple, multilevel piping network is analyzed. The network consists of a pump, connecting piping, an automatic temperature control valve (ATC), a coil, and balancing valves.

  3. Novel passive normally closed microfluidic valve

    CSIR Research Space (South Africa)

    Land, K

    2009-09-01

    Full Text Available -8 lithography and replication molding processes. It was successfully implemented, and initial results show the relationship between the applied pressure and flow rate. In addition to being used as a toggle valve, this design also allows...

  4. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. All rights reserved.

  5. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cylindrical, low-mass, high-efficiency, leak-proof cryogenic valve will be designed using composites and exotic metals. Based upon cryogenically-proven Venturi...

  6. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  7. A Hybrid Tissue-Engineered Heart Valve

    National Research Council Canada - National Science Library

    Alavi, S Hamed; Kheradvar, Arash

    2015-01-01

    This study describes the efforts to develop and test the first hybrid tissue-engineered heart valve whose leaflets are composed of an extra-thin superelastic Nitinol mesh tightly enclosed by uniform...

  8. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  9. Basis of valve operator selection for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H. S.; Lee, D. J.; See, J. K.; Park, C. K.; Choi, B. S

    2000-05-01

    SMART, an integral reactor with enhanced safety and operability, is under development for use of the nuclear energy. The valve operator of SMART system were selected through the data survey and technical review of potential valve fabrication vendors, and it will provide the establishment and optimization of the basic system design of SMART. In order to establish and optimize the basic system design of SMART, the basis of selection for the valve operator type were provided based on the basic design requirements. The basis of valve operator selection for SMART will be used as a basic technical data for the SMART basic and detail design and a fundamental material for the new reactor development in the future.

  10. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we report a case of an antenatal female in first trimester with aortic prosthetic valve thrombosis (PVT), who was successfully ...

  11. Boosting the superconducting spin valve effect in a metallic superconductor/ferromagnet heterostructure

    Energy Technology Data Exchange (ETDEWEB)

    Leksin, Pavel [Leibniz Institute for Solid State and Materials Research Dresden, IFW Dresden (Germany); Zavoisky Physical-Technical Institute, Russian Academy of Sciences, Kazan (Russian Federation); Kamashev, Andrey; Garifullin, Ilgiz [Zavoisky Physical-Technical Institute, Russian Academy of Sciences, Kazan (Russian Federation); Schumann, Joachim; Kataev, Vladislav; Thomas, Juergen [Leibniz Institute for Solid State and Materials Research Dresden, IFW Dresden (Germany); Buechner, Bernd [Leibniz Institute for Solid State and Materials Research Dresden, IFW Dresden (Germany); Technical University Dresden (Germany)

    2016-07-01

    We demonstrate a crucial role of the morphology of the superconducting layer for the operation of the multilayer S/F1/F2 spin valve. For that, we studied two types of superconducting spin valve heterostructures, with a rough and with a smooth superconducting layer, respectively, with transmission electron microscopy in combination with transport and magnetic characterization. We have found that the quality of the S/F interface is not critical for the S/F proximity effect as regards the suppression of the critical temperature of the S layer. However, it appears to be of a paramount importance for the performance of the S/F1/F2 spin valve. The magnitude of the conventional superconducting spin valve effect significantly increases, when the morphology of the S layer is changed from the type of overlapping islands to a smooth one. We attribute this drastic effect to a homogenization of the Green function of the superconducting condensate over the S/F interface in the S/F1/F2 valve with a smooth S layer surface.

  12. Giant Magnetoresistance of Cobalt-Copper Spin Valves

    Science.gov (United States)

    Butler, W. H.; Zhang, X.-G.; Speriosu, V. S.; Gurney, B. A.

    1996-03-01

    We report theoretical and experimental studies of the conductance and magnetoconductance of Co-Cu spin valves. Model results for structures consisting of 10 atomic 111 planes of Cu with 10 to 30 Co atomic planes on either side of the Cu layer are compared with results from magnetron sputtered Co|Cu|Co|FeMn spin valves. The theoretical calculations were performed using a fully quantum mechanical first principles technique and predict a contribution to the giant magnetoconductance (GMC) from channeling of majority electrons in the Cu layer if the Co-Cu interfaces are sufficiently smooth. This contribution to the GMC is essentially independent of the thickness of the Co layers. The other major contribution to the GMC arises from electrons which are accelerated by the electric field in one Co layer, propagate through the Cu and contribute to the current in the other Co layer. This contribution to the GMC, like the experimental result, increases approximately linearly with the thickness of the Co layers for Co thickness below 60Å Work at ORNL sponsored by USDOE Assistant Secretary of Defense Programs, Technology Management Group, Technology Transfer Initiative under contract DEAC05-84OR21400 with Lockheed Martin Energy Systems.

  13. Netiquette in Electronic Communication

    OpenAIRE

    Tomáš Kozík; Jozefína Slivová

    2014-01-01

    Electronic mail and electronic communications systems are considered significant and effective tools of communication. One of the most widespread electronic communication tools is e - mail communication. In order to avoid misinterpretation of the report on the side of the recipient, it is need to pay attention to the writing of e - mail messages as well as to their content. With the continuous expansion of the use of electronic communication there have gradually developed certain rules of...

  14. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) can improve the symptoms and prognosis of patients with severe aortic stenosis who, due to a high expected operative risk, would not have otherwise been treated surgically. If these patients develop prosthetic valve endocarditis, their presentations m...... treated medically, discuss the challenges in the diagnosis and management of such patients, and review available literature on the incidence and outcome of the condition. © 2012 Wiley Periodicals, Inc....

  15. Numerical simulation of mitral valve function

    OpenAIRE

    Lau, K. D.

    2012-01-01

    In the mammalian heart there are four heart valves (HV), of which the largest is the mitral valve (MV). Key components in the circulatory system, correct HV function is vital to cardiovascular health. A tethered and asymmetric structure, the MV regulates unidirectional flow between the left atrium and left ventricle. MVfunction is divided between systole/closure, where theMVis required to sustain a pressure load ~120 mmHg whilst minimising flow reversal, and diastole/opening in wh...

  16. Native valve Escherichia coli endocarditis following urosepsis

    Directory of Open Access Journals (Sweden)

    D Rangarajan

    2013-01-01

    Full Text Available Gram-negative organisms are a rare cause of infective endocarditis. Escherichia coli, the most common cause of urinary tract infection and gram-negative septicemia involves endocardium rarely. In this case report, we describe infection of native mitral valve by E. coli following septicemia of urinary tract origin in a diabetic male; subsequently, he required prosthetic tissue valve replacement indicated by persistent sepsis and congestive cardiac failure.

  17. Native valve Escherichia coli endocarditis following urosepsis

    OpenAIRE

    Rangarajan, D.; Ramakrishnan, S.; Patro, K. C.; Devaraj, S.; Krishnamurthy, V.; Kothari, Y.; Satyaki, N.

    2013-01-01

    Gram-negative organisms are a rare cause of infective endocarditis. Escherichia coli, the most common cause of urinary tract infection and gram-negative septicemia involves endocardium rarely. In this case report, we describe infection of native mitral valve by E. coli following septicemia of urinary tract origin in a diabetic male; subsequently, he required prosthetic tissue valve replacement indicated by persistent sepsis and congestive cardiac failure.

  18. Potential problems will drillstring safety valves

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    In the paper titled ``New generation drill string safety valves,`` presented at the IADC Well Control Conference for Europe, Aberdeen, May 22--24, 1996, documented limitations of presently available drillstring safety valves commonly used as kelly valves and stabbing valves were presented, and industry efforts to develop solutions to these problems were described. Authors of the paper are B.A. Tarr and R.A. Sukup (Mobil E and P Technology Center, Dallas), Dr. R. Luy (ITE, Clausthal, Germany), G. Rabby (Hi-Kalibre, Edmonton, Alberta) and J. Mertsch (ITAG, Celle, Germany). In 1995, the Task Group developed a draft of a new spec, and a DSSV testing program was initiated as a joint industry project, with the Gas Research Institute (GRI) as the major sponsor. Two manufacturers, Hi-Kalibre and ITAG, agreed to build new valves for the testing program. Hi-Kalibre, Edmonton, Alberta, supplied an already-commercial twin floating ball valve for November 1995 testing. This product is being used by Tesco in its portable top drive system. ITAG of Germany supplied a radically improved DSSV design, which was tested in December, and was to be retested in May following modifications.

  19. Europa Propulsion Valve Seat Material Testing

    Science.gov (United States)

    Addona, Brad M.

    2017-01-01

    The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

  20. A Hybrid Tissue-Engineered Heart Valve.

    Science.gov (United States)

    Alavi, S Hamed; Kheradvar, Arash

    2015-06-01

    This study describes the efforts to develop and test the first hybrid tissue-engineered heart valve whose leaflets are composed of an extra-thin superelastic Nitinol mesh tightly enclosed by uniform tissue layers composed of multiple cell types. The trileaflet Nitinol mesh scaffolds underwent three-dimensional cell culture with smooth muscle and fibroblast/myofibroblast cells enclosing the mesh, which were finally covered by an endothelial cell layer. Quantitative and qualitative assays were performed to analyze the microstructure of the tissues. A tissue composition almost similar to that of natural heart valve leaflets was observed. The function of the valves and their Nitinol scaffolds were tested in a heart flow simulator that confirmed the trileaflet valves open and close robustly under physiologic flow conditions with an effective orifice area of 75%. The tissue-metal attachment of the leaflets once exposed to physiologic flow rates was tested and approved. Our preliminary results indicate that the novel hybrid approach with nondegradable scaffold for engineering heart valves is viable and may address the issues associated with current tissue-engineered valves developed with degradable scaffolds. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Experimental study of asymmetric heart valve prototype

    Science.gov (United States)

    Vukicevic, M.; Fortini, S.; Querzoli, G.; Cenedese, A.; Pedrizzetti, G.

    2011-11-01

    The mechanical heart valves (MHVs) are extremely important medical devices, commonly used for diseased heart valves replacement. Despite the long term of use and constant design refinement, the MHVs are very far from ideal and their performance is very diverse from that of the native ones. It has been approved that small variations in geometry of valvular leaflets influence the significant change in the intraventricular vortical flow, known as one of the most important factors for the overall functionality of the heart. We have experimentally examined the home-made heart valve prototypes, exclusively modeled for the mitral valve replacement. The performance and energetic properties of the prototypes have been compared with those in the presence of standard MHVs. The analysis was based on the testing of intraventricular fluid dynamics, usually missing criteria for the quality of the valve performance. It has been shown that the asymmetric prototype, with unequal leaflets and D-shaped orifice produces flow patterns and energetic properties close to those found in the healthy subjects. Thus, the break of symmetry in the standard bi-leaflet MHV prosthesis, at least from the fluid dynamics point of view, is worthwhile to be considered for the design of MHVs for the mitral valve replacement.

  2. Combined mitral and tricuspid valve repair in rheumatic valve disease: fewer reoperations with prosthetic ring annuloplasty.

    Science.gov (United States)

    Bernal, José M; Pontón, Alejandro; Diaz, Begoña; Llorca, Javier; García, Iván; Sarralde, J Aurelio; Gutiérrez-Morlote, Jesús; Pérez-Negueruela, Carolina; Revuelta, José M

    2010-05-04

    We examined predictors of early and very long-term outcome after combined mitral and tricuspid valve repair for rheumatic disease. Between 1974 and 2002, 153 consecutive patients (mean age, 46.0+/-13.2 years) underwent combined mitral and tricuspid valve repair for rheumatic disease. Mitral disease was predominantly stenosis (82.3%); 100% of patients had organic tricuspid valve disease, predominantly with regurgitation (53.6%) or some degree of tricuspid stenosis (46.4%). Mitral repair included commissurotomy in 132 patients (86.3%) associated with a flexible annuloplasty in 108. Tricuspid valve repair included flexible annuloplasty in 68 patients (44.4%) and suture annuloplasty in 20 patients (13.1%) combined with tricuspid commissurotomy in 62 patients (42.5%). Thirty-day mortality was 5.9%. Late mortality was 60.1%. The median follow-up was 15.8 years (interquartile range, 6 to 19 years). Follow-up was 97.9% complete. Age>65 years was the only predictor of late mortality. Kaplan-Meier survival probability was 74.4% at 10 years and 57.0% at 15 years. Sixty-three patients required valve reoperation (mitral valve, 59; tricuspid valve, 38). Predictors of valve reoperations were either mitral or tricuspid commissurotomy without associated prosthetic ring annuloplasty. At 20 years, Kaplan-Meier freedom from reoperation was 48.5+/-5.1%. Combined mitral and tricuspid valve repair in rheumatic disease showed satisfactory early results. Long-term results were poor because of high mortality and a high number of valve-related reoperations. The use of prosthetic ring annuloplasty was significantly associated with a reduced incidence of both mitral and tricuspid valve reoperations.

  3. Comparative Matched Outcome of Evolut-R vs CoreValve Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    Landes, Uri; Bental, Tamir; Barsheshet, Alon; Assali, Abid; Vaknin Assa, Hana; Levi, Amos; Orvin, Katia; Kornowski, Ran

    2017-02-01

    The Evolut-R (Medtronic, Inc) is a transcatheter aortic valve implantation (TAVI) system that was built on the well-established foundation of Medtronic's CoreValve device platform. Although already in extensive clinical utilization, it is unknown if the Evolut-R improves TAVI outcomes. Herein, we compared TAVI outcomes of the Evolut-R and CoreValve devices. A propensity score 1:1 matching was conducted on 358 Evolut-R patients (n = 75) and CoreValve patients (n = 283). Thirty-day outcomes were compared using Valve Academic Research Consortium (VARC)-2 criteria. A combined 30-day endpoint including all-cause death, stroke, major vascular complication, major bleeding, implantation failure, paravalvular leak (PVL) ≥ moderate, and new pacemaker implantation was also tested. The final study group included 146 patients (73 Evolut-R; 73 CoreValve). Post matching, baseline characteristics were similar between the two groups. Mean patient age was 82 ± 6 years, mean STS score was 5.2 ± 3.8, 72% were female, and 17% were deemed frail. Implantation success reached 99% with Evolut-R and 94% with CoreValve (P=.10). Both groups had low periprocedural stroke/myocardial infarction/mortality rates and there was also no difference in 30-day vascular complications (P=.18), bleeding (P=.37), PVL (P=.24), and new pacemaker (P=.14). The combined outcome rate was 24% with Evolut-R and 37% with CoreValve (P=.10). This study indicates that the efficacy and safety of the self-expandable second-generation Evolut-R transcatheter valve is at least comparable with the first-generation CoreValve. The observed improved performance in correct positioning of a single valve and the numerically lower chance to suffer a combined TAVI endpoint needs further investigation.

  4. Use of oversized injectable valves in growing children for total repair of right ventricular outflow tract anomalies (preliminary results).

    Science.gov (United States)

    Deorsola, Luca; Abbruzzese, Pietro Angelo

    2014-08-01

    Right ventricular outflow tract surgery was originally confined to transannular patching, in the belief that pulmonary regurgitation was well tolerated. Because follow-up evaluations revealed the deleterious effects of pulmonary regurgitation, surgery today aims to spare or replace the valve. Available replacement devices have short lifetimes, considering growth mismatch in children. We hypothesize that oversizing the right infundibulum anticipates growth and that a squeezed prosthesis can complete the expansion process. The No-React® Injectable BioPulmonic Valve is designed for right infundibular surgery in adults, and hundreds of implants have shown promising results. We used this device for surgery in babies, with the addition of an innovative oversizing technique. This study evaluates our preliminary results and investigates whether such a technique might reduce growth mismatch. From September 2010 through July 2012, we implanted 11 injectable pulmonic valves. The median age of our patients was 23 months. After opening the right infundibulum, we enlarged it as much as possible with a wide patch. Before completing the patch suture, we injected an oversized valve. No problems occurred during surgery. No major insufficiency or leak was observed. We conclude that prostheses can be quite oversized and perform well even when not completely expanded. Oversized injectable pulmonic valves, shrunken to a smaller diameter, enabled the implantation of a device wider than otherwise possible, without affecting performance. Moreover, the prosthesis tended to return to its original size following growth, thereby reducing growth mismatch. Longer follow-up and larger numbers of patients are needed for verification.

  5. Matched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis: Insights From the Valve-in-Valve International Data Registry (VIVID).

    Science.gov (United States)

    Alnasser, Sami; Cheema, Asim N; Simonato, Matheus; Barbanti, Marco; Edwards, Jeremy; Kornowski, Ran; Horlick, Eric; Wijeysundera, Harindra C; Testa, Luca; Bedogni, Francesco; Amrane, Hafid; Walther, Thomas; Pelletier, Marc; Latib, Azeem; Laborde, Jean-Claude; Hildick-Smith, David; Kim, Won-Keun; Tchetche, Didier; Agrifoglio, Marco; Sinning, Jan-Malte; van Boven, Ad J; Kefer, Joëlle; Frerker, Christian; van Mieghem, Nicolas M; Linke, Axel; Worthley, Stephen; Asgar, Anita; Sgroi, Carmelo; Aziz, Mina; Danenberg, Haim D; Labinaz, Marino; Manoharan, Ganesh; Cheung, Anson; Webb, John G; Dvir, Danny

    2017-04-01

    Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding THV devices were analyzed using centralized core laboratory blinded to clinical events. St. Jude Medical Portico versus Medtronic CoreValve were compared in a 1:2 fashion after propensity score matching. A total of 162 patients, Portico- (n=54) and CoreValve- (n=108) based valve-in-valve procedures comprised the study population with no significant difference in baseline characteristics (age, 79±8.2 years; 60% women; mean STS [Society of Thoracic Surgery] score 8.1±5.5%). Postimplantation, CoreValve was associated with a larger effective orifice area (1.67 versus 1.31 cm2; P=0.001), lower mean gradient (14±7.5 versus 17±7.5 mm Hg; P=0.02), and lower core laboratory-adjudicated moderate-to-severe aortic insufficiency (4.2% versus 13.7%; P=0.04), compared with Portico. Procedural complications including THV malpositioning, second THV requirement, or coronary obstruction were not significantly different between the 2 groups. Survival and stroke rates at 30 days were similar, but overall mortality at 1 year was higher among patients treated with Portico compared with CoreValve (22.6% versus 9.1%; P=0.03). In this first matched comparison of THVs for valve-in-valve implantations, Portico and CoreValve demonstrated differences in postprocedural hemodynamics and long-term clinical outcomes. Although this could be related to THV design characteristics, the impact of other procedural factors cannot be excluded and require further evaluation. © 2017 American Heart Association, Inc.

  6. Transcatheter aortic valve implantation with the self-expandable venus A-Valve and CoreValve devices: Preliminary Experiences in China.

    Science.gov (United States)

    Liao, Yan-Biao; Zhao, Zhen-Gang; Wei, Xin; Xu, Yuan-Ning; Zuo, Zhi-Liang; Li, Yi-Jian; Zheng, Ming-Xia; Feng, Yuan; Chen, Mao

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has been demonstrated to be an effective alternative to surgical aortic valve replacement (SAVR) in patients with aortic stenosis who are deemed high risk or inoperable. Currently, TAVI procedures in China mostly make use of the domestic Venus A-Valve and the CoreValve; however, there is no data on their comparative performance. Consecutive patients undergoing TAVI with the aforementioned devices were included. The outcomes were reported according to the Valve Academic Research Consortium-2 (VARC) definitions. A total of 54 TAVI procedures were performed, 27 with the CoreValve and the other 27 with the Venus A-Valve. An additional valve was required in 4 (14.8%) and 3 (11.1%) patients, and the VARC-2 device success rates were 81.5 and 85.2%, respectively. The incidences of common complications were similar, except for the significantly less frequent pacemaker insertion in the Venus A-Valve group (7.4 vs. 37.0%, P = 0.03). Within 30 days, 2 (3.7%) patients died, 1 in each group, and both had a bicuspid aortic valve (BAV). No other serious complications, such as annular rupture, coronary obstruction and aortic dissection, occurred in the 32 BAV patients treated with the Venus A-Valve (14) or the CoreValve (18). After 2-years of follow-up, there was no significant difference between CoreValve group and Venus-A group (11.1 vs. 7.4%, P = 0.64). TAVI with the domestic Venus A-Valve is feasible, safe, and can produce favorable short-term outcomes comparable to those with the CoreValve in inoperable or high-risk patients with tricuspid and bicuspid aortic valve stenosis. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. Shape Memory Actuated Normally Open Permanent Isolation Valve

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Bacha, Caitlin E. (Inventor)

    2017-01-01

    A valve assembly for an in-space propulsion system includes an inlet tube, an outlet tube, a valve body coupling the inlet tube to the outlet tube and defining a propellant flow path, a valve stem assembly disposed within the valve body, an actuator body coupled to the valve body, the valve stem assembly extending from an interior of the valve body to an interior of the actuator body, and an actuator assembly disposed within the actuator body and coupled to the valve stem assembly, the actuator assembly including a shape memory actuator member that when heated to a transition temperature is configured to enable the valve stem assembly to engage the outlet tube and seal the propellant flow path.

  8. Low-Dose Gamma Irradiation of Decellularized Heart Valves Results in Tissue Injury In Vitro and In Vivo.

    Science.gov (United States)

    Helder, Meghana R K; Hennessy, Ryan S; Spoon, Daniel B; Tefft, Brandon J; Witt, Tyra A; Marler, Ronald J; Pislaru, Sorin V; Simari, Robert D; Stulak, John M; Lerman, Amir

    2016-02-01

    Decellularized heart valves are emerging as a potential alternative to current bioprostheses for valve replacement. Whereas techniques of decellularization have been thoroughly examined, terminal sterilization techniques have not received the same scrutiny. This study evaluated low-dose gamma irradiation as a sterilization method for decellularized heart valves. Incubation of valves and transmission electron microscopy evaluation after different doses of gamma irradiation were used to determine the optimal dose of gamma irradiation. Quantitative evaluation of mechanical properties was done by tensile mechanical testing of isolated cusps. Sterilized decellularized heart valves were tested in a sheep model (n = 3 [1 at 1,500 Gy and 2 at 3,000 Gy]) of pulmonary valve replacement. Valves sterilized with gamma radiation between 1,000 Gy and 3,000 Gy were found to be optimal with in vitro testing. However, in vivo testing showed deteriorating valve function within 2 months. On explant, the valve with 1,500 Gy gamma irradiation showed signs of endocarditis with neutrophils on hematoxylin and eosin staining, and positive gram stain resembling streptococcus infection. The 3,000 Gy valves had no evidence of infection, but the hematoxylin and eosin staining showed evidence of wound remodeling with macrophages and fibroblasts. Tensile strength testing showed decreased strength (0 Gy: 2.53 ± 0.98 MPa, 1,500 Gy: 2.03 ± 1.23 MPa, and 3,000 Gy: 1.26 ± 0.90 MPa) with increasing levels of irradiation. Low-dose gamma irradiation does not maintain the mechanical integrity of valves, and the balance between sterilization and damage may not be able to be achieved with gamma irradiation. Other methods of terminal sterilization must be pursued and evaluated. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Convergence of generalized eigenfunction expansions

    Directory of Open Access Journals (Sweden)

    Mayumi Sakata

    2007-05-01

    Full Text Available We present a simplified theory of generalized eigenfunction expansions for a commuting family of bounded operators and with finitely many unbounded operators. We also study the convergence of these expansions, giving an abstract type of uniform convergence result, and illustrate the theory by giving two examples: The Fourier transform on Hecke operators, and the Laplacian operators in hyperbolic spaces.

  10. Valve-in-valve outcome: design impact of a pre-existing bioprosthesis on the hydrodynamics of an Edwards Sapien XT valve.

    Science.gov (United States)

    Doose, Christian; Kütting, Maximilian; Egron, Sandrine; Farhadi Ghalati, Pejman; Schmitz, Christoph; Utzenrath, Marc; Sedaghat, Alexander; Fujita, Buntaro; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-03-01

    Bioprosthetic aortic heart valves are increasingly implanted in younger patients. Therefore, a strategy for potential valve failure should be developed before implanting the 'first valve'. The goal of this in vitro study was to provide insight into the effects of the design of a bioprosthesis on a valve-in-valve implanted Sapien XT valve. The hydrodynamic performance of a 23-mm Sapien XT valve implanted in Vascutek Aspire, Edwards Perimount, Medtronic Mosaic and St. Jude Medical Trifecta heart valves was investigated in a left heart simulator. In addition to the hydrodynamic results, the leaflet dynamics were analysed in high-speed video recordings of the tests. All valve-in-valve combinations in this study fulfilled the minimum acceptance criteria defined by relevant approval standards (e.g. ISO 5840) but displayed significant differences in their performances. Small inner diameters of the bioprostheses were associated with increased mean pressure gradients, decreased effective orifice areas and geometric opening areas as well as with pin-wheeling and uneven leaflet motion. In addition, implantation in bioprostheses with internally mounted leaflets was associated with lower paravalvular leakage. The results of this study suggest that a surgical bioprosthesis with a large inner diameter and internally mounted leaflets improves the heamodynamics and potentially the durability of a valve-in-valve combination. These results should give the attending physicians critical information to consider when deciding on a bioprosthesis for younger patients.

  11. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  12. Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung Han; Lefèvre, Thierry; Ahn, Jung Ming

    2016-01-01

    Background Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices.  Objective...

  13. Anterior mitral valve aneurysm perforation secondary to aortic valve endocarditis detected by Doppler colour flow mapping.

    Science.gov (United States)

    Decroly, P; Vandenbossche, J L; Englert, M

    1989-02-01

    We report a case of mitral valve aneurysm formation and perforation, secondary to Streptococcus sanguis endocarditis of the aortic valve. Aneurysm formation was documented by cross-sectional echocardiography and its perforation was established by Doppler colour flow mapping, and subsequently confirmed at surgery.

  14. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure

  15. Bjork-Shiley convexoconcave valves: Susceptibility artifacts at brain MR imaging and mechanical valve fractures

    NARCIS (Netherlands)

    van Gorp, Maarten J.; van der Graaf, Yolanda; de Mol, Bas A. J. M.; Bakker, Chris J. G.; Witkamp, Theo D.; Ramos, Lino M. P.; Mali, Willem P. T. M.

    2004-01-01

    PURPOSE: To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Bjork-Shiley convexoconcave (BSCC) valves. MATERIALS AND METHODS: MR images of the brain were obtained in 58 patients with prosthetic heart

  16. [Heart valve prosthesis and pregnancy].

    Science.gov (United States)

    Ben-Ismail, M; Fekih, M; Taktak, M; Chelli, M

    1979-02-01

    Sixteen pregnancies were followed up in 13 patients with prosthetic heart valves: 8 pregnancies went to term under oral anticoagulation, 4 under heparin and 4 without anticoagulation. 9 healthy normal children were delivered; there were 2 still births and 5 abortions. On the maternal side 3 haemorrhages and thromboembolic episodes which involved 2 patients on heparin, one of whom died, were observed. The following points are apparent from our observations and a review of the existing medical literature: --the risk of thromboembolism is not increased. The marked clotting tendency of maternal blood post-partum contraindicates the withdrawal of anticoagulants during this critical period; --haemorrhagic complications are common with anticoagulants; --foetal loss is greatly increased; --the teratogenecity of vitamin-K antagonists is certain, but the risk is small. The problems of anticoagulation are discussed; theoretically heparin should be given during the 1st trimestre and from the 38th week to the second post-partum week. The patients should be closely supervised by both obstetrician and cardiologist and hospitalisation is advised for the last month of pregnancy. Normal vaginal delivery is usually possible.

  17. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  18. Simplified surgical-hybrid Melody valve implantation for paediatric mitral valve disease.

    Science.gov (United States)

    Hofmann, Michael; Dave, Hitendu; Hübler, Michael; Kretschmar, Oliver

    2015-05-01

    Children suffering from left atrioventricular valve (LAVV) disease not amenable to repair represent a significant challenge. The results of surgical reconstruction are not optimal. Valve replacement as an alternative is associated with poor results. The surgical-hybrid approach with implantation of a stented biological valve (bovine jugular vein graft, Melody valve) seems to represent a new therapeutic option. Here we demonstrate our case, the consideration and the approach to extreme clinical findings in a small child. We describe a simplified surgical-hybrid Melody valve implantation in a LAVV position. The technique of implantation is relatively simple and the immediate postoperative result very good. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Use of phase change materials during compressed air expansion for isothermal CAES plants

    Science.gov (United States)

    Castellani, B.; Presciutti, A.; Morini, E.; Filipponi, M.; Nicolini, A.; Rossi, F.

    2017-11-01

    Compressed air energy storage (CAES) plants are designed to store compressed air into a vessel or in an underground cavern and to expand it in an expansion turbine when energy demand is high. An innovative CAES configuration recently proposed is the isothermal process. Several methods to implement isothermal CAES configuration are under investigation. In this framework, the present paper deals with the experimental testing of phase change materials (PCM) during compressed air expansion phase. The experimental investigation was carried out by means of an apparatus constituted by a compression section, a steel pressure vessel, to which an expansion valve is connected. The initial internal absolute pressure was equal to 5 bar to avoid moisture condensation and the experimental tests were carried out with two paraffin-based PCM amounts (0.05 kg and 0.1 kg). Results show that the temperature change during air expansion decreases with increasing the PCM amount inside the vessel. With the use of PCM during expansions an increase of the expansion work occurs. The increase is included in the range from 9.3% to 18.2%. In every test there is an approach to the isothermal values, which represent the maximum theoretical value of the obtainable expansion work.

  20. Thrombolytic therapy in prosthetic valve thrombosis during early pregnancy

    Directory of Open Access Journals (Sweden)

    B.C. Srinivas

    2012-01-01

    Full Text Available Regardless of the improvements in the design of prosthetic heart valves and the use of anticoagulation, systemic embolism and valve thrombosis remains the most dreaded complications of mechanical heart valve replacement. A course of thrombolytic therapy may be considered as a first-line therapy for prosthetic heart valve thrombosis. The safety of thrombolysis in early pregnancy is not known. We describe a primigravida with mitral valve replacement status presenting with acute prosthetic valve thrombosis and treated successfully with intravenous streptokinase.

  1. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  2. On the Bantu expansion.

    Science.gov (United States)

    Rowold, Daine J; Perez-Benedico, David; Stojkovic, Oliver; Garcia-Bertrand, Ralph; Herrera, Rene J

    2016-11-15

    Here we report the results of fine resolution Y chromosomal analyses (Y-SNP and Y-STR) of 267 Bantu-speaking males from three populations located in the southeast region of Africa. In an effort to determine the relative Y chromosomal affinities of these three genotyped populations, the findings are interpreted in the context of 74 geographically and ethnically targeted African reference populations representing four major ethno-linguistic groups (Afro-Asiatic, Niger Kordofanin, Khoisan and Pygmoid). In this investigation, we detected a general similarity in the Y chromosome lineages among the geographically dispersed Bantu-speaking populations suggesting a shared heritage and the shallow time depth of the Bantu Expansion. Also, micro-variations in the Bantu Y chromosomal composition across the continent highlight location-specific gene flow patterns with non-Bantu-speaking populations (Khoisan, Pygmy, Afro-Asiatic). Our Y chromosomal results also indicate that the three Bantu-speaking Southeast populations genotyped exhibit unique gene flow patterns involving Eurasian populations but fail to reveal a prevailing genetic affinity to East or Central African Bantu-speaking groups. In addition, the Y-SNP data underscores a longitudinal partitioning in sub-Sahara Africa of two R1b1 subgroups, R1b1-P25* (west) and R1b1a2-M269 (east). No evidence was observed linking the B2a haplogroup detected in the genotyped Southeast African Bantu-speaking populations to gene flow from contemporary Khoisan groups. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Effect of transcatheter aortic valve size and position on valve-in-valve hemodynamics: An in vitro study.

    Science.gov (United States)

    Azadani, Ali N; Reardon, Michael; Simonato, Matheus; Aldea, Gabriel; Nickenig, Georg; Kornowski, Ran; Dvir, Danny

    2017-06-01

    Transcatheter heart valve implantation in failed aortic bioprostheses (valve-in-valve [ViV]) is an increasingly used therapeutic option for high-risk patients. However, high postprocedural gradients are a significant limitation of aortic ViV. Our objective was to evaluate Medtronic CoreValve Evolut R ViV hemodynamics in relation to the degree of device oversizing and depth of implantation. Evolut R devices of 23 and 26 mm were implanted within 21-, 23-, and 25-mm Hancock II bioprostheses. Small and gradual changes in implantation depth were attempted. Hemodynamic testing was performed in a pulse duplicator under ISO-5840 standard. A total of 47 bench-testing experiments were performed. The mean gradient of the 26-mm Evolut R in 23- and 25-mm Hancock II was lower than 23-mm Evolut R (P  17.5 mm. The current comprehensive bench-testing assessment demonstrates the importance of both transcatheter heart valve size and device position for the attainment of optimal hemodynamics during ViV procedures. Additional in vitro testing may be required to develop hemodynamics-based guidelines for device sizing in ViV procedures in degenerated surgical bioprostheses. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Pilot licensing after aortic valve surgery.

    Science.gov (United States)

    Syburra, Thomas; Schnüriger, Hans; Kwiatkowski, Barbara; Graves, Kirk; Reuthebuch, Oliver; Genoni, Michele

    2010-05-01

    Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is

  5. Lined 10'' butterfly valve outlasts competitive valves in brine filter system

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, A.

    1982-03-01

    One of the world's largest chlorine production units located in the Gulf Coast area has an extensive brine piping system with a large number of valves. Some of the valves performed well but many failed to meet the service requirements, especially in the brine filtering system with the salt solution at ambient temperatures and pressures about 100 psi. One of these was a 10'' valve. Various types of gear-operated butterfly valves, with an elastomer lining to withstand the somewhat corrosive solution, had been tried but developed leaks and had to be repaired or replaced after 4 to 6 months. The valves became difficult or impossible to operate in some cases when brine leaking past the stem seal attacked the inner surface of the metal valve body and the liner was dislodged by the movement of the disc. In September 1980, a 10'' butterfly valve specifically designed for bubble-tight shut off and zero stem leakage was installed in the brine filter line on a trial basis. The valve has a 1-piece, epoxy-coated ductile iron body with a molded one-piece liner of Hypalon rubber, and a stainless steel stem and disc with splines instead of pins to provide a trouble-free connection. The stem is positively sealed against leakage by a patented spherical machining process on both the disc and the liner. The valve was furnished with a variable ratio gear actuator that has higher torque output when the disc begins to make contact with the seat to assure a bubble-tight shutoff with minimum input torque. The butterfly valve has provided leaktight performance since it was installed in September 1980 and is still easy to open and close by the geared actuator.

  6. Loss of Axin2 results in impaired heart valve maturation and subsequent myxomatous valve disease.

    Science.gov (United States)

    Hulin, Alexia; Moore, Vicky; James, Jeanne M; Yutzey, Katherine E

    2017-01-01

    Myxomatous valve disease (MVD) is the most common aetiology of primary mitral regurgitation. Recent studies suggest that defects in heart valve development can lead to heart valve disease in adults. Wnt/β-catenin signalling is active during heart valve development and has been reported in human MVD. The consequences of increased Wnt/β-catenin signalling due to Axin2 deficiency in postnatal valve remodelling and pathogenesis of MVD were determined. To investigate the role of Wnt/β-catenin signalling, we analysed heart valves from mice deficient in Axin2 (KO), a negative regulator of Wnt/β-catenin signalling. Axin2 KO mice display enlarged mitral and aortic valves (AoV) after birth with increased Wnt/β-catenin signalling and cell proliferation, whereas Sox9 expression and collagen deposition are decreased. At 2 months in Axin2 KO mice, the valve extracellular matrix (ECM) is stratified but distal AoV leaflets remain thickened and develop aortic insufficiency. Progressive myxomatous degeneration is apparent at 4 months with extensive ECM remodelling and focal aggrecan-rich areas, along with increased BMP signalling. Infiltration of inflammatory cells is also observed in Axin2 KO AoV prior to ECM remodelling. Overall, these features are consistent with the progression of human MVD. Finally, Axin2 expression is decreased and Wnt/β-catenin signalling is increased in myxomatous mitral valves in a murine model of Marfan syndrome, supporting the importance of Wnt/β-catenin signalling in the development of MVD. Altogether, these data indicate that Axin2 limits Wnt/β-catenin signalling after birth and allows proper heart valve maturation. Moreover, dysregulation of Wnt/β-catenin signalling resulting from loss of Axin2 leads to progressive MVD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  7. Compact in-place gate valve for molecular-beam experiments

    OpenAIRE

    Küpper, J.; Haak, H.; Wohlfart, K.; Meijer, G.

    2006-01-01

    A high vacuum gate valve for skimmed molecular beam experiments is described. It is designed with a very short extent of only 10 mm along the molecular beam axis to minimize the distance between the molecular beam source and the experiment to provide the maximum molecular flux to the experiment. At the same time it provides free space on both sides of the skimmer to not disturb the supersonic expansion in front of the skimmer, to give optical access to the full distance between beam source an...

  8. Pressure drop and temperature rise in He II flow in round tubes, Venturi flowmeters and valves

    Science.gov (United States)

    Walstrom, P. L.; Maddocks, J. R.

    1988-01-01

    Pressure drops in highly turbulent He II flow were measured in round tubes, valves, and Venturi flowmeters. Results are in good agreement with single-phase flow correlations for classical fluids. The temperature rise in flow in a round tube was measured, and found to agree well with predictions for isenthalpic expansion. Cavitation was observed in the venturis under conditions of low back pressure and high flow rate. Metastable superheating of the helium at the venturi throat was observed before the helium made a transition to saturation pressure.

  9. LMFBR large valve development. Comparison study of advantages and disadvantages of foreign design of offset pivot butterfly valves with AMCO's offset pivot ball valve

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, L.

    1975-02-01

    The purpose of this effort was to compare the advantages and disadvantages of foreign designs of offset pivot butterfly valves presented during a specialists meeting on Operating Experience and Design Criteria of Sodium Valves with the characteristics of the present AMCO offset pivot ball valve design concept. In addition, the comparison was directed to indicating if work on a butterfly concept should be initiated by AMCO. This work could be in parallel with or in lieu of, the present AMCO effort on an offset pivot ball valve for isolation valve purposes.

  10. Durability of pericardial versus porcine bioprosthetic heart valves.

    Science.gov (United States)

    Grunkemeier, Gary L; Furnary, Anthony P; Wu, YingXing; Wang, Lian; Starr, Albert

    2012-12-01

    To compare the probability, and modes, of explantation for Carpentier-Edwards pericardial versus porcine valves. Our porcine series began in 1974 and our pericardial series in 1991, with annual prospective follow-up. We used the Kaplan-Meier method and Cox regression for estimation and analysis of patient mortality, and the cumulative incidence function and competing risks regression for estimation and analysis of valve durability. Through the end of 2010, we had implanted 506 porcine and 2449 pericardial aortic valves and 181 porcine and 163 pericardial mitral valves. The corresponding total and maximum follow-up years were 3471 and 24, 11,517 and 18, 864 and 22, and 645 and 9. The corresponding probabilities (cumulative incidence function) of any valve explant were 7%, 8%, 22%, and 8%, and of explant for structural valve deterioration were 4%, 5%, 16%, and 5% at 15 years for the first 3 series and at 8 years for the fourth (pericardial mitral valve) series. Using competing risks regression for structural valve deterioration explant, with age, gender, valve size, and concomitant coronary bypass surgery as covariates, a slight (subhazard ratio, 0.79), but nonsignificant, protective effect was found for the pericardial valve in the aortic position and a greater (subhazard ratio, 0.31) and almost significant (P = .08) protective effect of the pericardial valve in the mitral position. Leaflet tear was responsible for 61% of the structural valve deterioration explants in the porcine series and 46% in the pericardial series. Using competing risks regression, the pericardial valve had a subhazard ratio for structural valve deterioration explant of less than 1 in both positions, approaching statistical significance in the mitral position. The mode of structural valve deterioration was predominantly leaflet tear for porcine valves and fibrosis/calcification for pericardial valves. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc

  11. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  12. Cardiac crossroads: deciding between mechanical or bioprosthetic heart valve replacement

    Directory of Open Access Journals (Sweden)

    Maggie N Tillquist

    2011-02-01

    Full Text Available Maggie N Tillquist1, Thomas M Maddox21School of Medicine, University of Colorado Denver, Denver, CO, USA; 2VA Eastern Colorado Health Care System, and Department of Medicine (Cardiology, University of Colorado Denver, Denver, CO, USAAbstract: Nearly 15 million people in the United States suffer from either aortic or mitral valvular disease. For patients with severe and symptomatic valvular heart disease, valve replacement surgery improves morbidity and mortality outcomes. In 2009, 90,000 valve replacement surgeries were performed in the United States. This review evaluates the advantages and disadvantages of mechanical and bioprosthetic prosthetic heart valves as well as the factors for consideration in deciding the appropriate valve type for an individual patient. Although many caveats exist, the general recommendation is for patients younger than 60 to 65 years to receive mechanical valves due to the valve's longer durability and for patients older than 60 to 65 years to receive a bioprosthetic valve to avoid complications with anticoagulants. Situations that warrant special consideration include patient co-morbidities, the need for anticoagulation, and the potential for pregnancy. Once these characteristics have been considered, patients' values, anxieties, and expectations for their lifestyle and quality of life should be incorporated into final valve selection. Decision aids can be useful in integrating preferences in the valve decision. Finally, future directions in valve technology, anticoagulation, and medical decision-making are discussed.Keywords: prosthetic heart valves, patient preference, valve type, anticoagulant, structural valve deterioration 

  13. Valvular Heart Disease in Adults: Management of Prosthetic Heart Valves.

    Science.gov (United States)

    Trujillo, John F; Hollenberg, Steven M

    2017-06-01

    Patients undergoing cardiac valve replacement may receive mechanical or bioprosthetic valves. Mechanical valves require lifelong anticoagulation but are durable and the need for a second surgery is up to eightfold times less than with bioprosthetic valves. Bioprosthetic valves do not require lifelong anticoagulation and thus are associated with fewer bleeding complications but they are less durable and associated with higher morbidity and mortality rates, particularly in younger patients. Anticoagulation with mechanical valves is achieved using warfarin; use of direct-acting oral anticoagulants is not indicated. Concomitant low-dose aspirin is recommended for patients with mechanical valves and as sole thromboembolism prophylaxis for patients receiving aortic or mitral bioprosthetic valves. If a patient taking warfarin is to undergo a surgical procedure that requires interruption of anticoagulation, bridging therapy with heparin is indicated if the patient has a mechanical aortic valve and any risk of thromboembolism, an older-generation mechanical aortic valve, or a mechanical mitral valve. Warfarin is teratogenic; pregnant women should take heparin. Patients with mechanical or bioprosthetic valves should receive antibiotic prophylaxis before some dental and surgical procedures to prevent endocarditis. Thrombolytic therapy should be considered in patients who develop a thrombus on a valve that does not resolve with heparin. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  14. Osseous and chondromatous metaplasia in calcific aortic valve stenosis.

    Science.gov (United States)

    Torre, Matthew; Hwang, David H; Padera, Robert F; Mitchell, Richard N; VanderLaan, Paul A

    2016-01-01

    Aortic valve replacement for calcific aortic valve stenosis is one of the more common cardiac surgical procedures. However, the underlying pathophysiology of calcific aortic valve stenosis is poorly understood. We therefore investigated the histologic findings of aortic valves excised for calcific aortic valve stenosis and correlated these findings with their associated clinical features. We performed a retrospective analysis on 6685 native aortic valves excised for calcific stenosis and 312 prosthetic tissue aortic valves with calcific degeneration at a single institution between 1987 and 2013. Patient demographics were correlated with valvular histologic features diagnosed on formalin-fixed, decalcified, and paraffin embedded hematoxylin and eosin stained sections. Of the analyzed aortic valves, 5200 (77.8%) were tricuspid, 1473 (22%) were bicuspid, 11 (0.2%) were unicuspid, and 1 was quadricuspid. The overall prevalence of osseous and/or chondromatous metaplasia was 15.6%. Compared to tricuspid valves, bicuspid valves had a higher prevalence of metaplasia (30.1% vs. 11.5%) and had an earlier mean age of excision (60.2 vs. 75.1 years old). In addition, the frequency of osseous metaplasia and/or chondromatous metaplasia increased with age at time of excision of bicuspid aortic valves, while tricuspid aortic valves showed the same incidence regardless of patient age. Males had a higher prevalence of metaplasia in both bicuspid (33.5% vs. 22.3%) and tricuspid (13.8% vs. 8.6%) aortic valves compared to females. Osseous metaplasia and/or chondromatous metaplasia was also more common in patients with bicuspid aortic valves and concurrent chronic kidney disease or atherosclerosis than in those without (33.6% vs. 28.3%). No osseous or chondromatous metaplasia was observed within the cusps of any of the prosthetic tissue valves. Osseous and chondromatous metaplasia are common findings in native aortic valves but do not occur in prosthetic tissue aortic valves. Bicuspid

  15. TOPICAL REVIEW: Negative thermal expansion

    Science.gov (United States)

    Barrera, G. D.; Bruno, J. A. O.; Barron, T. H. K.; Allan, N. L.

    2005-02-01

    There has been substantial renewed interest in negative thermal expansion following the discovery that cubic ZrW2O8 contracts over a temperature range in excess of 1000 K. Substances of many different kinds show negative thermal expansion, especially at low temperatures. In this article we review the underlying thermodynamics, emphasizing the roles of thermal stress and elasticity. We also discuss vibrational and non-vibrational mechanisms operating on the atomic scale that are responsible for negative expansion, both isotropic and anisotropic, in a wide range of materials.

  16. Thermal Expansion of Polyurethane Foam

    Science.gov (United States)

    Lerch, Bradley A.; Sullivan, Roy M.

    2006-01-01

    Closed cell foams are often used for thermal insulation. In the case of the Space Shuttle, the External Tank uses several thermal protection systems to maintain the temperature of the cryogenic fuels. A few of these systems are polyurethane, closed cell foams. In an attempt to better understand the foam behavior on the tank, we are in the process of developing and improving thermal-mechanical models for the foams. These models will start at the microstructural level and progress to the overall structural behavior of the foams on the tank. One of the key properties for model characterization and verification is thermal expansion. Since the foam is not a material, but a structure, the modeling of the expansion is complex. It is also exacerbated by the anisoptropy of the material. During the spraying and foaming process, the cells become elongated in the rise direction and this imparts different properties in the rise direction than in the transverse directions. Our approach is to treat the foam as a two part structure consisting of the polymeric cell structure and the gas inside the cells. The polymeric skeleton has a thermal expansion of its own which is derived from the basic polymer chemistry. However, a major contributor to the thermal expansion is the volume change associated with the gas inside of the closed cells. As this gas expands it exerts pressure on the cell walls and changes the shape and size of the cells. The amount that this occurs depends on the elastic and viscoplastic properties of the polymer skeleton. The more compliant the polymeric skeleton, the more influence the gas pressure has on the expansion. An additional influence on the expansion process is that the polymeric skeleton begins to breakdown at elevated temperatures and releases additional gas species into the cell interiors, adding to the gas pressure. The fact that this is such a complex process makes thermal expansion ideal for testing the models. This report focuses on the thermal

  17. Electrical Textile Valves for Paper Microfluidics.

    Science.gov (United States)

    Ainla, Alar; Hamedi, Mahiar M; Güder, Firat; Whitesides, George M

    2017-10-01

    This paper describes electrically-activated fluidic valves that operate based on electrowetting through textiles. The valves are fabricated from electrically conductive, insulated, hydrophobic textiles, but the concept can be extended to other porous materials. When the valve is closed, the liquid cannot pass through the hydrophobic textile. Upon application of a potential (in the range of 100-1000 V) between the textile and the liquid, the valve opens and the liquid penetrates the textile. These valves actuate in less than 1 s, require low energy (≈27 µJ per actuation), and work with a variety of aqueous solutions, including those with low surface tension and those containing bioanalytes. They are bistable in function, and are, in a sense, the electrofluidic analog of thyristors. They can be integrated into paper microfluidic devices to make circuits that are capable of controlling liquid, including autonomous fluidic timers and fluidic logic. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Radiological findings of congenital urethral valves

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyung Mo; Kook, Shin Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Congenital urethral valve is the common cause of hydronephrosis in newborn infants and the most common cause of bladder outlet obstruction in male children. We reviewed and analysed radiological findings and associated anomalies of 16 cases of congenital urethral valve which were examined during the period from January 1985 to December 1989. The most frequent age was under one year old (56%). The main symptoms were urinary dribbing (37.5%), weak stream (25%) and urinary frequency and incontinence (25%). Anterior urethral valve (AUV) was 5 cases (31%) and posterior urethral valve (PUV) was 11 cases(69%), in which 10 cases were Type I and one case was Type III. Bladder wall thickening was seen in all cases and its severity was partly correlated with the degree of vesicoureteral reflux (VUR). VUR was observed in 12 cases (75%), and relatively severe in older age group. The degree of VUR was milder in AUV than PUV. Hydronephrosis was more severe in PUV than in anterior one, and its degree was correlated with the severity of VUR. Associated anomalies were ectopic urethral opening (2 cases), PDA (1 case), congenital megacolon (1 case) and patent urachus (1 case) in PUV. So early diagnosis and treatment of congenital urethral valve is essential to the prevention of renal damage.

  19. TCT-670 Optimal Transcatheter Heart Valve Sizing in Aortic Valve in Valve Implantation: Insights from the Valve in Valve International Data (VIVID) Registry

    DEFF Research Database (Denmark)

    Alnasser, Sami; Cheema, Asim N; Horlick, Eric

    2016-01-01

    )/true ID x 100. Results: A total of 595 patients (359 for standard size and 236 for oversized group) were included in the analysis. Baseline clinical, hemodynamic and surgical valve parameters were similar in these two groups. Both groups used similar THV devices in each matched comparison. The oversized.......1±8.1mmHg vs. 17.4±8.5mmHg, p=0.002) in comparison to the standard cohort. The oversized group however, had a higher rate of moderate to severe AI (6.9% vs. 2.7%, p=0.001) and second THV requirement (5.5%vs. 2.2%, p=0.04). THV mal-positioning, coronary obstruction and postoperative pacemaker requirement...

  20. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Science.gov (United States)

    Zhang, Ben; Chen, Xiang; Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. This design of the

  1. Transseptal transcatheter mitral valve-in-valve: A step by step guide from preprocedural planning to postprocedural care.

    Science.gov (United States)

    Guerrero, Mayra; Salinger, Michael; Pursnani, Amit; Pearson, Paul; Lampert, Mark; Levisay, Justin; Russell, Hyde; Feldman, Ted

    2017-05-30

    Transcatheter mitral valve replacement has been successfully performed with the use of aortic transcatheter heart valves in hundreds of patients worldwide with severe dysfunction of a degenerated mitral bioprosthesis and high surgical risk for repeat operation. The delivery approach in the vast majority of the mitral valve-in-valve procedures has been transapical. Although the transseptal approach may be more technically challenging, it is less invasive and may be preferred by patients. Data from case series and a large international registry suggest that patients treated with transseptal mitral valve-in-valve have faster recovery, more improvement in left ventricular ejection fraction and possibly lower mortality compared with patients treated with transapical approach. A prospective clinical trial, the MITRAL trial (Mitral Implantation of TRAnscatheter vaLves) is evaluating the safety and feasibility of transvenous transseptal mitral valve-in-valve. The experience from this trial has allowed us to improve our procedural approach. In anticipation of a wider adoption of the transseptal approach for mitral valve-in-valve, we describe our current method step-by-step from planning the procedure through postprocedural management. This is an evolving technique that has changed with experience and the transition to newer generation transcatheter heart valve devices. We discuss the use of cardiac computed tomography for planning the procedure including transseptal puncture and valve size selection, provide procedural and technical tips, and discuss postprocedural care. © 2017 Wiley Periodicals, Inc.

  2. Mechanical Designs for Relief Valves for Cryogenic Apparatuses and Installations

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    There are also pressure relief valves with warm seat available on which the set pressure is based on an adjustment of forces by permanent magnets. Pressure vessel rules allows also the choice for an active triggered pressure relief valve (Cont...

  3. Recognizing the Symptoms of Worsening Heart Valve Disease

    Science.gov (United States)

    ... be hard to separate our habits from the mechanics of our hearts, which is one important reason ... About Heart Valves • Heart Valve Problems and Causes • Risks, Signs and Symptoms Introduction Understanding Symptoms Recognizing Symptoms ...

  4. TRINITY heart valve prosthesis: a novel repositionable and retrievable transapical transcatheter aortic valve system.

    Science.gov (United States)

    Hengstenberg, Christian; Condado, Jose; Garcia, David; Martinez, Milka Marin; La Forgia, Giambattista; Ebner, Adrian; Gallo, Santiago; Silva, Enrique; Holzamer, Andreas; Husser, Oliver; Hilker, Michael

    2015-03-01

    Transcatheter aortic valve implantation (TAVI) has become a viable option for selected high-risk patients with severe and symptomatic aortic stenosis. First- and second-generation TAVI devices are either self- or balloon-expandable, and are often not repositionable or not fully retrievable, leading to suboptimal positioning in some cases. This may result in paravalvular regurgitation, AV conduction delay, or compromise of coronary perfusion. A broader application of TAVI requires advances in both valve and delivery systems. Therefore, in order to facilitate accurate positioning, to minimise paravalvular leakage, possibly to reduce the risk of AV conduction delay, and possibly to be able to abort the procedure, a "next-generation" TAVI system has been developed which is repositionable and retrievable, the TRINITY heart valve system. The TRINITY heart valve system was implanted in a first-in-human study using the transapical approach to demonstrate feasibility and procedural success. All endpoints were adjudicated according to VARC definitions at seven and 30 days. The TRINITY heart valve system was implanted in a 74-year-old patient with severe symptomatic aortic valve stenosis. In this case, repositioning of the TRINITY resulted in optimal position without paravalvular leakage and with perfect function. The TRINITY heart valve is a repositionable and retrievable TAVI system. Both the implantation result and short-term clinical and haemodynamic outcome were excellent.

  5. Echocardiographic anatomy of the mitral valve in healthy dogs and dogs with myxomatous mitral valve disease.

    Science.gov (United States)

    Wesselowski, S; Borgarelli, M; Menciotti, G; Abbott, J

    2015-06-01

    To further characterize the echocardiographic anatomy of the canine mitral valve apparatus in normal dogs and in dogs affected by myxomatous mitral valve disease (MMVD). Twenty-two normal dogs and 60 dogs with MMVD were prospectively studied. The length (AMVL), width (AMVW) and area (AMVA) of the anterior mitral valve leaflet were measured in the control group and the affected group, as were the diameters of the mitral valve annulus in diastole (MVAd) and systole (MVAs). The dogs with MMVD were staged based on American College of Veterinary Internal Medicine (ACVIM) guidelines and separated into groups B1 and B2/C. All measurements were indexed to body weight based on empirically defined allometric relationships. There was a statistically significant relationship between all log10 transformed mitral valve dimensions and body weight. The AMVL, AMVW, AMVA, MVAd and MVAs were all significantly greater in the B2/C group compared to the B1 and control groups. The AMVW was also significantly greater in the B1 group compared to the control group. Interobserver % coefficient of variation (% CV) was mitral valve leaflet and the mitral valve annulus in the dog can be indexed to body weight based on allometric relationships. Preliminary reference intervals have been proposed over a range of body sizes. Relative to normal dogs, AMVL, AMVW, AMVA, MVAd and MVAs are greater in patients with advanced MMVD. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Balloon expandable transcatheter heart valves for native mitral valve disease with severe mitral annular calcification.

    Science.gov (United States)

    Guerrero, Mayra; Urena, Marina; Pursnani, Amit; Wang, Dee D; Vahanian, Alec; O'Neill, William; Feldman, Ted; Himbert, Dominique

    2016-06-01

    Patients with mitral annular calcification (MAC) have high surgical risk for mitral valve replacement due to associated comorbidities and technical challenges related to calcium burden, precluding surgery in many patients. Transcatheter mitral valve replacement (TMVR) with the compassionate use of balloon expandable aortic transcatheter heart valves has been used in this clinical scenario. The purpose of this review was to summarize the early experience including successes and failures reported. TMVR might evolve into an acceptable alternative for selected patients with severe MAC who are not candidates for conventional mitral valve surgery. However, this field is at a very early stage and the progress will be significantly slower than the development of transcatheter aortic valve replacement due to the complexity of the mitral valve anatomy and its pathology. Optimizing patient selection process by using multimodality imaging tools to accurately measure the mitral valve annulus and evaluate the risk of left ventricular outflow tract obstruction is essential to minimize complications. Strategies for treating and preventing left ventricular outflow tract obstruction are being tested. Similarly, carefully selecting candidates avoiding patients at the end of their disease process, might improve the overall outcomes.

  7. Thermostat valve 2.0. Self sufficient, radio operated actuators and thus possible new control concepts; Thermostatventil 2.0. Energieautarke funkgesteuerte Stellantriebe und dadurch moegliche neuartige Regelkonzepte

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, Arne [Fachhochschule Muenster, Steinfurt (Germany). Labor fuer MSR-Technik und Gebaeudeautomation; Gloesekoetter, Peter [Fachhochschule Muenster, Steinfurt (Germany). Labor fuer Halbleiter-Bauelemente und Bussysteme

    2010-07-01

    At present, in co-operation between the laboratory for electronic components of the Faculty of Electrical Engineering and the laboratory for MSR Engineering and Building Automation of the Faculty of Energy, Building, Environment of the University of Applied Sciences Muenster (Federal Republic of Germany) one investigates the substitution of the classical thermostat valve by the ''Thermostat Valve 2.0'' as a new solution. At the same time this enables new control concepts.

  8. Compact UHV valve with field replaceable windows

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D. (Brookhaven National Lab., Upton, NY (United States)); Freeman, J. (VAT, Inc., Woburn, MA (United States)); Powell, F. (Luxel, Inc., Friday Harbor, WA (United States))

    1991-01-01

    There are many applications in synchrotron radiation research where window valves can be usefully employed. Examples include gas cells for monochromator calibration, filters for high order light rejection, and as vacuum isolation elements between machine and experimental vacua. Often these devices are fairly expensive, and have only fixed (ie non-removable) windows. The development of a new type of seal technology by VAT for their series 01 valves provides a gate surface which is free from obstructions due to internal mechanical elements. This feature allows a threaded recess to be machined into the gate to receive a removable window frame which can carry standard size Luxel thin film windows. The combination of these features results in a DN 40 (2.75in. conflat flange) valve which provides a clear aperture of 21mm diameter for the window material. 8 refs., 2 figs.

  9. Cardiac Rehabilitation After Heart Valve Surgery

    DEFF Research Database (Denmark)

    Pollmann, Agathe Gerwina Elena; Frederiksen, Marianne; Prescott, Eva

    2017-01-01

    PURPOSE: Evidence of the effect of cardiac rehabilitation (CR) after heart valve surgery is scarce, but nevertheless CR is recommended for this group of patients. Therefore, this study assessed the effect of CR on exercise capacity, cardiovascular risk factors, and long-term mortality and morbidity......, as well as predictors for enrolment in or failing to complete CR. METHODS: A review of medical records identified 250 patients who underwent heart valve surgery between January 2009 and August 2013. Of these, 211 patients eligible for CR were identified. Effect of CR was assessed by peak oxygen uptake.......58-15.06). CONCLUSIONS: CR after heart valve surgery improved exercise capacity and was associated with reduced morbidity. Elderly and ethnic minorities were less likely to attend or complete CR and deserve special attention....

  10. Piezogenic pedal papules with mitral valve prolapse

    Directory of Open Access Journals (Sweden)

    Cihan Altin

    2016-01-01

    Full Text Available Piezogenic pedal papules (PPP are herniations of subcutaneous adipose tissue into the dermis. PPP are skin-colored to yellowish papules and nodules on lateral surfaces of feet that typically become apparent when the patient stands flat on his/her feet. Some connective tissue diseases and syndromes have been reported in association with PPP. Mitral valve prolapse (MVP is a myxomatous degeneration of the mitral valve, characterized by the displacement of an abnormally thickened mitral valve leaflet into the left atrium during systole. MVP may be isolated or part of a heritable connective tissue disorder. PPP, which is generally considered as an isolated lesion, might be also a predictor of some cardiac diseases associated with connective tissue abnormalities such as MVP. A detailed systemic investigation including cardiac examination should be done in patients with PPP. Since in the literature, there are no case reports of association of PPP with MVP, we report these cases.

  11. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  12. Interlayer reliant magnetotransport in graphene spin valve

    Science.gov (United States)

    Iqbal, Muhammad Zahir; Hussain, Ghulam; Siddique, Salma; Iqbal, Muhammad Waqas

    2017-11-01

    Here the magnetotransport properties of vertical spin valve structures incorporating graphene (Gr), Gr/Au and Gr/Al2O3 intervening layers are elucidated. An in-plane magnetic field is obliquely applied to the device with the purpose to vary the relative magnetizations of ferromagnetic electrodes (Co and Ni). The relative magnetoresistance (MR) of Co/Gr/Ni is enhanced from ∼0.16% to 0.57% by simply passivating the bottom Ni electrode with thin Au film. On the other hand, depositing Al2O3 on the bottom ferromagnetic layer in such a spin valve junction not only increases the magnitude of MR (∼-0.52%) but also reverses its polarity. Furthermore, the linear current-voltage characteristics for graphene and graphene/Au spin valve devices specifies ohmic contact, while non-linear curves indicate tunneling behavior for graphene/Al2O3 device.

  13. Magneto-Seebeck effect in spin valves

    Science.gov (United States)

    Zhang, X. M.; Wan, C. H.; Wu, H.; Tang, P.; Yuan, Z. H.; Zhang, Q. T.; Zhang, X.; Tao, B. S.; Fang, C.; Han, X. F.

    2017-10-01

    The magneto-Seebeck (MS) effect, which is also called magneto-thermo-power, was observed in Co/Cu/Co and NiFe/Cu/Co spin valves. Their Seebeck coefficients in the parallel state were larger than those in the antiparallel state, and the MS ratio defined as (SAP -SP)/SP could reach -9% in our case. The MS effect originated not only from trivial giant magnetoresistance but also from spin current generated due to spin-polarized thermoelectric conductivity of ferromagnetic materials and subsequent modulation of the spin current by different spin configurations in spin valves. A simple Mott two-channel model reproduced a -11% MS effect for the Co/Cu/Co spin valves, qualitatively consistent with our observations. The MS effect could be applied for simultaneously sensing the temperature gradient and the magnetic field and also be possibly applied to determine spin polarization of thermoelectric conductivity and the Seebeck coefficient of ferromagnetic thin films.

  14. Strategic Complexity and Global Expansion

    DEFF Research Database (Denmark)

    Oladottir, Asta Dis; Hobdari, Bersant; Papanastassiou, Marina

    2012-01-01

    The purpose of this paper is to analyse the determinants of global expansion strategies of newcomer Multinational Corporations (MNCs) by focusing on Iceland, Israel and Ireland. We argue that newcomer MNCs from small open economies pursue complex global expansion strategies (CGES). We distinguish....... The empirical evidence suggests that newcomer MNCs move away from simplistic dualities in the formulation of their strategic choices towards more complex options as a means of maintaining and enhancing their global competitiveness....

  15. Estimates of expansion time scales

    Science.gov (United States)

    Jones, E. M.

    Monte Carlo simulations of the expansion of a spacefaring civilization show that descendants of that civilization should be found near virtually every useful star in the Galaxy in a time much less than the current age of the Galaxy. Only extreme assumptions about local population growth rates, emigration rates, or ship ranges can slow or halt an expansion. The apparent absence of extraterrestrials from the solar system suggests that no such civilization has arisen in the Galaxy.

  16. Exhaust gas bypass valve control for thermoelectric generator

    Science.gov (United States)

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  17. AeroValve Experimental Test Data Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, Mark W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-09-01

    This report documents the collection of experimental test data and presents performance characteristics for the AeroValve brand prototype pneumatic bidirectional solenoid valves tested at the Oak Ridge National Laboratory (ORNL) in July/August 2014 as part of a validation of AeroValve energy efficiency claims. The test stand and control programs were provided by AeroValve. All raw data and processing are included in the report attachments.

  18. Modal-Based Design Improvement of a Butterfly Valve Disc

    OpenAIRE

    Marius Draghiciu; Zoltan-Iosif Korka; Gilbert-Rainer Gillich

    2017-01-01

    The dynamic behaviour control of a butterfly valve is important because, when one of the valve disc natural frequency is close to the frequency of vortex shedding, which appears when the valve is fully open or partially closed, resonance may appear and vibration with significant amplitudes is generated. This paper presents an example by how the design of a butterfly valve disc can be improved by using a modal analysis performed by means of the finite element method. For this purpose, the rese...

  19. Numerical study of cavitating flow inside a flush valve

    OpenAIRE

    BAYEUL-LAINE, Annie-Claude; Simonet, Sophie; DUTHEIL, Daniel; Caignaert, Guy

    2011-01-01

    In water supply installations, noise pollution often occurs. As a basic component of a system, a flush valve may frequently be a source of noise and vibration generated by cavitation or high turbulence levels. During valve closing or valve opening, cavitation can be a problem. In order to decrease the noise and to improve the design inside a flush valve, some experimental and numerical analyses were carried out in our laboratories. These analyses led to some improvements in the de...

  20. Surgery for rheumatic tricuspid valve disease: a 30-year experience.

    Science.gov (United States)

    Bernal, José M; Pontón, Alejandro; Diaz, Begoña; Llorca, Javier; García, Iván; Sarralde, Aurelio; Diago, Carmen; Revuelta, José M

    2008-08-01

    This study was undertaken to assess factors influencing short- and long-term outcomes of surgery for rheumatic disease of the tricuspid valve. Between 1974 and 2005, a total of 328 consecutive patients (mean age 51.3 +/- 13.6 years) underwent tricuspid valve surgery for rheumatic disease. There were 12 cases of isolated tricuspid lesion, 199 of triple-valve disease, 114 of tricuspid and mitral valve disease, and 3 of aortic and tricuspid valve disease. Most patients (72%) had predominantly tricuspid regurgitation. Tricuspid valve prosthetic replacement was performed in 31 cases and valve repair in 297. In-hospital mortality was 7.6%. Late mortality was 52.1%, whereas the expected mortality of the Spanish population of the same age was 24.2%. Predictors of in-hospital mortality were male sex, isolated tricuspid lesion, moderate aortic insufficiency, postclamping time, and tricuspid valve replacement. Mean follow-up was 8.7 years (range 1-31 years). Follow-up was 98.9% complete. Predictors of late mortality were age, New York Heart Association functional class IV, postclamping time, and mitral valve replacement. In total, 114 patients required valve reoperation, but only 4 (3.5%) for isolated tricuspid valve dysfunction. At 30 years, actuarial survival was 12.1% +/- 4.4%, actuarial freedom from reoperation was 27.5% +/- 5.8%, and actuarial freedom from valve-related complications was 2.0% +/- 1.3%. Organic tricuspid valve disease associated with rheumatic mitral or aortic lesions increases hospital and late mortality, but valve repair compared favorably with valve replacement. Long-term results may be considered acceptable for otherwise incurable valve disease.

  1. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  2. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  3. [Quality in aortic valve replacement--how good have hybrid valves have to be?].

    Science.gov (United States)

    Aicher, D; Groesdonk, H V; Schäfers, H-J

    2009-10-01

    The current enthusiasm with the development of catheter-based aortic valve replacement suggests a critical appraisal of the quality of conventional techniques. Currently surgical treatment of diseased aortic valves includes different methods that can be employed with a low risk. Risk prediction is difficult, the Euroscore largely overestimates mortality. By comparison, there is no evidence that the risk of implantation is reduced by catheter-based implantation. Specific complications (stroke, AV-block, perivalvular leak) are more frequent compared to conventional replacement. Despite the current enthusiasm over the feasibility of catheter-based implantation of hybrid aortic valves they should still be used cautiously. Georg Thieme Verlag KG Stuttgart, New York.

  4. Tissue engineering of heart valves: PEGylation of decellularized porcine aortic valve as a scaffold for in vitro recellularization.

    Science.gov (United States)

    Zhou, Jianliang; Hu, Shidong; Ding, Jingli; Xu, Jianjun; Shi, Jiawei; Dong, Nianguo

    2013-09-05

    Poly (ethylene glycol) (PEG) has attracted broad interest for tissue engineering applications. The aim of this study was to synthesize 4-arm -PEG-20kDa with the terminal group of diacrylate (4-arm-PEG-DA) and evaluate its dual functionality for decellularized porcine aortic valve (DAV) based on its mechanical and biological properties. 4-arm-PEG-DA was synthesized by graft copolymerization of linear PEG 20,000 monomers, and characterized by IR1H NMR and 13C NMR; PEGylation of DAV was achieved by the Michael addition reaction between propylene acyl and thiol, its effect was tested by uniaxial planar tensile testing, hematoxylin and eosin (HE) and scanning electron microscopy (SEM). Gly-Arg-Gly-Asp-Ser-Pro-Cys (GRGDSPC) peptides and vascular endothelial growth factor-165 (VEGF165) were conjugated onto DAV by branched PEG-DA (GRGDSPC-PEG-DAV-PEG-VEGF165). Mechanical testing confirmed that PEG-cross-linking significantly enhanced the tensile strength of DAV. Immunofluoresce confirmed the GRGDSPC peptides and VEGF165 were conjugated effectively onto DAV; the quantification of conjunction was completed roughly using spectrophotometry and ELISA. The human umbilical vein endothelial cells (HUVECs) grew and spread well on the GRGDSPC-PEG-DAV-PEG-VEGF165. Therefore, PEGylation of DAV not only can improve the tensile strength of DAV, and can also mediate the conjugation of bioactive molecule (VEGF165 and GRGDSPC peptides) on DAV, which might be suitable for further development of tissue engineered heart valve.

  5. Morphological and Chemical Study of Pathological Deposits in Human Aortic and Mitral Valve Stenosis: A Biomineralogical Contribution

    Directory of Open Access Journals (Sweden)

    Valentina Cottignoli

    2015-01-01

    Full Text Available Aim of this study was to investigate heart valve calcification process by different biomineralogical techniques to provide morphological and chemical features of the ectopic deposit extracted from patients with severe mitral and aortic valve stenosis, to better evaluate this pathological process. Polarized light microscopy and scanning electron microscopy analyses brought to light the presence of nodular and massive mineralization forms characterized by different levels of calcification, as well as the presence of submicrometric calcified globular cluster, micrometric cavities containing disorganized tissue structures, and submillimeter pockets formed by organic fibers very similar to amyloid formations. Electron microprobe analyses showed variable concentrations of Ca and P within each deposit and the highest content of Ca and P within calcified tricuspid aortic valves, while powder X-ray diffraction analyses indicated in the nanometer range the dimension of the pathological bioapatite crystals. These findings indicated the presence of highly heterogeneous deposits within heart valve tissues and suggested a progressive maturation process with continuous changes in the composition of the valvular tissue, similar to the multistep formation process of bone tissue. Moreover the micrometric cavities represent structural stages of the valve tissue that immediately precedes the formation of heavily mineralized deposits such as bone-like nodules.

  6. Assessment of slurry pressure letdown valve and slurry block valve technology for direct coal liquefaction demonstration and pioneer commercial plants

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, R.P.

    1984-10-01

    This report examines the status of the technology of high pressure slurry letdown valves and slurry block valves in coal liquefaction service. All of the demonstration and pioneer commercial direct liquefaction plant designs call for the use of high pressure slurry letdown valves for flow control and slurry block valves for flow isolation. Successful performance and reliability of these valves is a serious concern because of the severity of the process streams and the limited experience and performance data on these valves under such conditions. The objectives of this report are: (1) to examine the existing data base on these valves from the four major direct coal liquefaction pilot plants in the US, (2) to present the recommendations from the pilot plant experience, (3) to examine the specifications for the letdown and block valves in the demonstration/pioneer commercial designs, and (4) to identify the scale-up issues, data gaps, and development and testing needs. 23 references, 20 figures, 7 tables.

  7. Remote operated valves - the Bolivian approach

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar, O.; Arce, G.; Blanco, E.; Collazos, A.; Chavarria, E. [Transredes S.A., Transporte de Hidrocarburos, La Paz (Bolivia)

    2005-07-01

    For pipeline operators, the Remote Operated Valves (ROV) are tools to isolate pipe segments and contain any potential spill and they are also useful tools to provide data on operating conditions. Projects and articles about the locations and site layouts were developed to install Remote Operated Valves and the criteria for their use; each location has its own environmental, social and logistical particulars. This article describes the approach used to install ROV in Bolivia and the final design installed discussions and lessons learned about the: criteria to define the location, layout equipment installed and shelter and particulars of the location. (author)

  8. Left Ventricular Pseudoaneurysm after Valve Replacement

    Directory of Open Access Journals (Sweden)

    Jun Ho Lee

    2015-02-01

    Full Text Available We present a case of left ventricular pseudoaneurysm, which is a very rare and fatal complication of cardiac procedures such as mitral valve replacement. A 55-year-old woman presented to the Department of Thoracic and Cardiovascular Surgery at Hanyang University Seoul Hospital with chest pain. Ten years prior, the patient had undergone double valve replacement due to aortic regurgitation and mitral steno-insufficiency. Surgical repair was successfully performed using a prosthetic pericardial patch via a left lateral thoracotomy.

  9. The serpentine mitral valve and cerebral embolism

    Directory of Open Access Journals (Sweden)

    Ker James

    2011-02-01

    Full Text Available Abstract Valvular strands, well-delineated filiform masses, attached to cardiac valve edges are associated with cerebral embolism and stroke. Strokes, caused by emboli from valvular strands, tend to occur among younger persons. In this case report a valvular strand, giving a peculiar serpentine appearance to the mitral valve is described. This mitral valvular strand was the only explanation for an episode of cerebral embolism, presenting with a transient right sided hemiparesis. It is proposed that a randomized study involving combined treatment with aspirin and clopidogrel is warranted in young patients with valvular strands, presenting with a first episode of cerebral embolism.

  10. Torque limited drive for manual valves

    Science.gov (United States)

    Elliott, Philip G.; Underwood, Daniel E.

    1989-01-01

    The present invention is directed to a torque-limiting handwheel device for preventing manual valves from being damaged due to the application of excessive torque during the opening or closing operation of the valves. Torque can only be applied when ridges in the handwheel assembly engage in channels machined in the face of the baseplate. The amount of torque required for disengagement of the ridges from the channels is determined by the force exerted by various Bellville springs and the inclination of the side faces of the channels.

  11. Computer tomographic findings in mitral valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Heuser, L.; Neufang, K.F.R.; Jansen, W.

    1984-04-01

    In 38 patients suffering from mitral valve disease the findings of cardiac CT scans were compared to the results of echocardiographic, standard roentgenographic, and cineangiocardiographic studies as well as to intraoperative and histological findings. CT proved to be superior to the other imaging modalities in detecting mitral calcifications and in demonstrating the morphological changes, but cannot replace cardiac catheterization as it does not yield haemodynamic data. The indication for CT in mitral valve disease therefore is restricted to cases with extremely enlarged left atria in which the other methods do not provide satisfactory visualization, and to patients with suspected intracavitary thrombus or tumor. 8 figs.

  12. Multimodality Imaging of Heart Valve Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, Ronak, E-mail: Dr.R.Rajani@gmail.com [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom); Khattar, Rajdeep [Department of Cardiology, Royal Brompton Hospital, London (United Kingdom); Chiribiri, Amedeo [Divisions of Imaging Sciences, The Rayne Institute, St. Thomas' Hospital, London (United Kingdom); Victor, Kelly; Chambers, John [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom)

    2014-09-15

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

  13. Autonomous valve for detection of biopolymer degradation

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Noeth, Nadine-Nicole; Fetz, Stefanie

    2009-01-01

    We present a polymer microvalve that allows the detection of biopolymer degradation without the need of external energy. The valve is based on a polymer container filled with a colored marker solution and closed by a thin lid. This structure is covered by a film of poly(L-lactide) and degradation...... of the biopolymer triggers the release of the color which is detected visually. The autonomous valve has potential for the fast testing of biopolymer degradation under various environmental conditions or by specific enzymes....

  14. Pregnancy Outcomes in Women With Aortic Valve Substitutes

    NARCIS (Netherlands)

    Heuvelman, Helena J.; Arabkhani, Bardia; Cornette, Jerome M. J.; Pieper, Petronella G.; Bogers, Ad J. J. C.; Takkenberg, Johanna J. M.; Roos-Hesselink, Jolien W.

    2013-01-01

    Young women who require aortic valve replacement need information on the potential cardiac and obstetric complications of pregnancy for the different valve substitutes available. We, therefore, assessed the pregnancy outcomes in women who had received an autograft, homograft, or mechanical valve in

  15. 46 CFR 61.05-20 - Boiler safety valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping... INSPECTIONS Tests and Inspections of Boilers § 61.05-20 Boiler safety valves. Each safety valve for a drum, superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. ...

  16. The Bundle of His in Prosthetic Heart Valve Replacement*

    African Journals Online (AJOL)

    1973-01-27

    Jan 27, 1973 ... sudden deaths which occur following heart valve replace- ment. In our local cardiac surgery unit at Groote Schuur. Hospital, the hospital mortality rate for aortic valve replacement with the University of Cape Town (VeT) aortic valve prosthesis between March 1963 and October. 1968, was 120. 0 according to ...

  17. Intermittent intravalvar regurgitation of a mechanical aortic valve ...

    African Journals Online (AJOL)

    Mechanical prosthetic valve regurgitation may be either periprosthetic or intraprosthetic. The later is usually mild, occurring in the majority of normally functioning valves and is due to the 'regurgitant flow' closing the valve. An unusual case is reported of intermitent intraprosthetic regurgitation through a normally functioning ...

  18. Low-power piezoelectric micro-machined valve

    Science.gov (United States)

    Gianchandani, Yogesh B. (Inventor); Nellis, Gregory Francis (Inventor); Klein, Sanford A. (Inventor); Park, John Moon (Inventor); Evans, Allan Thomas (Inventor); Taylor, Ryan (Inventor); Brosten, Tyler R. (Inventor)

    2010-01-01

    A piezoelectric microvalve employs a valve element formed of hermetically sealed and opposed plates flexed together by a cross axis piezoelectric element. Large flow modulation with small piezoelectric actuator displacement is obtained by perimeter augmentation of the valve seat which dramatically increases the change in valve flow area for small deflections.

  19. 49 CFR 230.52 - Water glass valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Water glass valves. 230.52 Section 230.52... Water Glasses and Gauge Cocks § 230.52 Water glass valves. All water glasses shall be equipped with no more than two valves capable of isolating the water glass from the boiler. They shall also be equipped...

  20. The Heimlich Valve for Pleural Cavity Drainage | Makanga | Annals ...

    African Journals Online (AJOL)

    One-way valve systems such as the Heimlich valve are small, portable apparatus that allow regulation of fluid flow and require minimal nursing care other than daily charting. Methods: A retrospective descriptive analysis of all chest drains connected to a Heimlich valve between January 2009 and December 2012. Data on ...

  1. 49 CFR 192.181 - Distribution line valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution line valves. 192.181 Section 192.181 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... line valves. (a) Each high-pressure distribution system must have valves spaced so as to reduce the...

  2. 46 CFR 154.546 - Excess flow valve: Closing flow.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Excess flow valve: Closing flow. 154.546 Section 154.546... and Process Piping Systems § 154.546 Excess flow valve: Closing flow. (a) The rated closing flow of vapor or liquid cargo for an excess flow valve must be specially approved by the Commandant (CG-522). (b...

  3. The Warm, Rich Sound of Valve Guitar Amplifiers

    Science.gov (United States)

    Keeports, David

    2017-01-01

    Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier…

  4. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance: Transmission lines. 192.745... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.745 Valve maintenance: Transmission lines. (a) Each transmission line valve that might be required during any emergency...

  5. Perioperative anticoagulation for children with prosthetic mechanical valves

    OpenAIRE

    Grech, Victor E.; Rees, Philip G.

    2000-01-01

    The insertion of a mechanical heart valve predisposes to thrombosis and embolism, and for this reason, individuals with mechanical valves who undergo dental/surgical procedures must take special precautions. In this article, we illustrate a protocol for anticoagulation during such procedures in individuals with mechanical valves.

  6. Porcine vena cava as an alternative to bovine pericardium in bioprosthetic percutaneous heart valves.

    Science.gov (United States)

    Munnelly, Amy E; Cochrane, Leonard; Leong, Joshua; Vyavahare, Naren R

    2012-01-01

    Percutaneous heart valves are revolutionizing valve replacement surgery by offering a less invasive treatment option for high-risk patient populations who have previously been denied the traditional open chest procedure. Percutaneous valves need to be crimped to accommodate a small-diameter catheter during deployment, and they must then open to the size of heart valve. Thus the material used must be strong and possess elastic recoil for this application. Most percutaneous valves utilize bovine pericardium as a material of choice. One possible method to reduce the device delivery diameter is to utilize a thin, highly elastic tissue. Here we investigated porcine vena cava as an alternative to bovine pericardium for percutaneous valve application. We compared the structural, mechanical, and in vivo properties of porcine vena cava to those of bovine pericardium. While the extracellular matrix fibers of pericardium are randomly oriented, the vena cava contains highly aligned collagen and elastin fibers that impart strength to the vessel in the circumferential direction and elasticity in the longitudinal direction. Moreover, the vena cava contains a greater proportion of elastin, whereas the pericardium matrix is mainly composed of collagen. Due to its high elastin content, the vena cava is significantly less stiff than the pericardium, even after crosslinking with glutaraldehyde. Furthermore, the vena cava's mechanical compliance is preserved after compression under forces similar to those exerted by a stent, whereas pericardium is significantly stiffened by this process. Bovine pericardium also showed surface cracks observed by scanning electron microscopy after crimping that were not seen in vena cava tissue. Additionally, the vena cava exhibited reduced calcification (46.64 ± 8.15 μg Ca/mg tissue) as compared to the pericardium (86.79 ± 10.34 μg/mg). These results suggest that the vena cava may provide enhanced leaflet flexibility, tissue resilience, and tissue

  7. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    OpenAIRE

    Ben Zhang; Xiang Chen; Tong-yi Xu; Zhi-gang Zhang; Xin Li; Lin Han; Zhi-yun Xu

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmo...

  8. Modeling and Investigation of Electromechanical Valve Train Actuator at simulated Pressure conditions

    DEFF Research Database (Denmark)

    Habib, Tufail

    2012-01-01

    In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about investig......In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about...

  9. Concomitant mitral valve surgery with aortic valve replacement: a 21-year experience with a single mechanical prosthesis

    Directory of Open Access Journals (Sweden)

    Sidhu Pushpinder

    2007-05-01

    Full Text Available Abstract Background Long-term survival for combined aortic and mitral valve replacement appears to be determined by the mitral valve prosthesis from our previous studies. This 21-year retrospective study assess long-term outcome and durability of aortic valve replacement (AVR with either concomitant mitral valve replacement (MVR or mitral valve repair (MVrep. We consider only a single mechanical prosthesis. Methods Three hundred and sixteen patients underwent double valve replacement (DVR (n = 273 or AVR+MVrep (n = 43, in the period 1977 to 1997. Follow up of 100% was achieved via telephone questionnaire and review of patients' medical records. Actuarial analysis of long-term survival was determined by Kaplan-Meier method. The Cox regression model was used to evaluate potential predictors of mortality. Results There were seventeen cases (5.4% of early mortality and ninety-six cases of late mortality. Fifteen-year survival was similar in both groups at 44% and 57% for DVR and AVR+MVrep respectively. There were no significant differences in valve related deaths, anticoagulation related complications, or prosthetic valve endocarditis between the groups. There were 6 cases of periprosthetic leak in the DVR group. Sex, pre-operative mitral and aortic valve pathology or previous cardiac surgery did not significantly affect outcome. Conclusion The mitral valve appears to be the determinant of survival following double valve surgery and survival is not significantly influenced by mitral valve repair.

  10. 30 CFR 250.445 - What are the requirements for kelly valves, inside BOPs, and drill-string safety valves?

    Science.gov (United States)

    2010-07-01

    ... motor and use drill pipe instead of a kelly, you must install one kelly valve above, and one strippable kelly valve below, the joint of drill pipe used in place of a kelly; (d) On a top-drive system equipped..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources MINERALS...

  11. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  12. Mitraclip Followed by Surgical Aortic Valve Replacement: Hybrid Techniques for Regurgitant Aortic and Mitral Valve Disease.

    Science.gov (United States)

    Eudailey, Kyle; Hamid, Nadira; Hahn, Rebecca T; Kodali, Susheel; Gray, William; George, Isaac

    2016-08-01

    With the advent of percutaneous valve interventions, the landscape for management of high-risk valve replacement and repair has changed dramatically. Transcatheter valve repair/replacement techniques can be used in conjunction with open surgery to facilitate a hybrid approach in patients with multivalve disease. We present a case of staged hybrid valve repair followed by surgical replacement for a high-risk patient with mitral regurgitation and aortic regurgitation. This case illustrates the effectiveness of the staged hybrid approach for high-risk patients with incomplete transcatheter options. We expect these techniques to play an increasingly larger role in the treatment algorithm for high-risk multivalve disease. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... distortion. (b) Exhalation valves shall be: (1) Protected against damage and external influence; and (2... or in the hose fitting near the facepiece of all Type A, AE, B, and BE supplied-air respirators. ...

  14. Transvalvular pressure gradients for different methods of mitral valve repair: only neochordoplasty achieves native valve gradients.

    Science.gov (United States)

    Jahren, Silje Ekroll; Hurni, Samuel; Heinisch, Paul Philipp; Winkler, Bernhard; Obrist, Dominik; Carrel, Thierry; Weber, Alberto

    2018-02-01

    Many surgical and interventional methods are available to restore patency for patients with degenerative severe mitral valve regurgitation. Leaflet resection and neochordoplasty, which both include ring annuloplasty, are the most frequently performed techniques for the repair of posterior mitral leaflet flail. It is unclear which technique results in the best haemodynamics. In this study, we investigated the effect of different mitral valve reconstruction techniques on mitral valve haemodynamics and diastolic transvalvular pressure gradient in an ex vivo porcine model. Eight porcine mitral valves were tested under pulsatile flow conditions in an in vitro pulsatile flow loop for haemodynamic quantification. Severe acute posterior mitral leaflet flail was created by resecting the posterior marginal chorda. The acute mitral valve regurgitation was corrected using 4 different repair techniques, in each valve, in a strictly successive order: (i) neochordoplasty with polytetrafluoroethylene sutures alone and (ii) with ring annuloplasty, (iii) edge-to-edge repair and (iv) triangular leaflet resection, both with ring annuloplasty. Valve haemodynamics were measured and quantified for all valve configurations (native, rupture and each surgical reconstruction). The results were analysed using a validated statistical linear mixed model, and the P-values were calculated using a 2-sided Wald test. All surgical reconstruction techniques were able to sufficiently correct the acute mitral valve regurgitation. Neochordoplasty without ring annuloplasty was the only reconstruction technique that resulted in haemodynamic properties similar to the native mitral valve (P-values from 0.071 to 0.901). The diastolic transvalvular gradient remained within the physiological range for all reconstructions but was significantly higher than in the native valve for neochordoplasty with ring annuloplasty (P < 0.000), edge-to-edge repair (P < 0.000) and leaflet resection (P < 0

  15. Effectiveness of rivaroxaban for thromboprophylaxis of prosthetic heart valves in a porcine heterotopic valve model.

    Science.gov (United States)

    Greiten, Lawrence E; McKellar, Stephen H; Rysavy, Joseph; Schaff, Hartzell V

    2014-05-01

    Warfarin is used to reduce the risk of stroke and thromboembolic complications in patients with mechanical heart valves. Yet, despite frequent blood testing, its poor pharmacokinetic and pharmacodynamic profiles often result in variable therapeutic levels. Rivaroxaban is a direct competitive factor Xa inhibitor that is taken orally. It inhibits the active site of factor Xa without the need for the cofactor antithrombin, and thus, its mechanism of action is differentiated from that of the fractionated heparins and indirect factor Xa inhibitors. No in vivo data exist regarding the effectiveness of rivaroxaban in preventing thromboembolic complications of mechanical heart valves. We tested the hypothesis that rivaroxaban is as effective as enoxaparin for thromboprophylaxis of mechanical valves that use a previously described heterotopic aortic valve porcine model. A modified bileaflet mechanical valved conduit that bypassed the native, ligated descending thoracic aorta was implanted into 30 swine. Postoperatively, the animals were randomly assigned to groups receiving no anticoagulation (n = 10), enoxaparin at 2 mg/kg subcutaneously twice daily (n = 10) or rivaroxaban at 2 mg/kg orally twice daily (n = 10). The amount of valve thrombus was measured on post-implantation day 30 as the primary end point. Quantitative evaluation of radiolabelled platelet deposition on the valve prostheses was done and embolic and haemorrhagic events were measured as secondary end points. Animals with no anticoagulation had a thrombus mean of 759.9 mg compared with 716.8 mg with enoxaparin treatment and 209.6 mg with rivaroxaban treatment (P = 0.05 for enoxaparin vs rivaroxaban). Similarly, the mean number of platelets deposited on the valve prosthesis was lower in the rivaroxaban group (6.13 × 10(9)) than in the enoxaparin group (3.03 × 10(10)) (P = 0.03). In this study, rivaroxaban was more effective than enoxaparin for short-term thromboprophylaxis of mechanical valve prosthetics in

  16. The effect of electrodes on 11 acene molecular spin valve: Semi-empirical study

    Science.gov (United States)

    Aadhityan, A.; Preferencial Kala, C.; John Thiruvadigal, D.

    2017-10-01

    A new revolution in electronics is molecular spintronics, with the contemporary evolution of the two novel disciplines of spintronics and molecular electronics. The key point is the creation of molecular spin valve which consists of a diamagnetic molecule in between two magnetic leads. In this paper, non-equilibrium Green's function (NEGF) combined with Extended Huckel Theory (EHT); a semi-empirical approach is used to analyse the electron transport characteristics of 11 acene molecular spin valve. We examine the spin-dependence transport on 11 acene molecular junction with various semi-infinite electrodes as Iron, Cobalt and Nickel. To analyse the spin-dependence transport properties the left and right electrodes are joined to the central region in parallel and anti-parallel configurations. We computed spin polarised device density of states, projected device density of states of carbon and the electrode element, and transmission of these devices. The results demonstrate that the effect of electrodes modifying the spin-dependence behaviours of these systems in a controlled way. In Parallel and anti-parallel configuration the separation of spin up and spin down is lager in the case of iron electrode than nickel and cobalt electrodes. It shows that iron is the best electrode for 11 acene spin valve device. Our theoretical results are reasonably impressive and trigger our motivation for comprehending the transport properties of these molecular-sized contacts.

  17. Predictors of permanent pacemaker implantation after transfemoral aortic valve implantation with the Lotus valve.

    Science.gov (United States)

    Keßler, Mirjam; Gonska, Birgid; Seeger, Julia; Rottbauer, Wolfgang; Wöhrle, Jochen

    2017-10-01

    Permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation is of high clinical relevance, but PPMI rates differ widely between valve types. Although the Lotus valve can be repositioned, reported rates for PPMI are high. The predictors of PPMI after Lotus valve implantation have not been defined yet. We analyzed the impact of preexisting conduction disturbances, depth of implantation, oversizing, and amount of calcification on PPMI in 216 patients with severe symptomatic aortic stenosis underdoing Lotus valve implantation. PPMI was required in 39.8% of patients. Patients with need for PPMI compared with patients without need for PPMI had more often the following criteria: male gender (P=.035); preprocedural right bundle-branch block (RBBB) (16.3% vs 0, P<.001); atrioventricular (AV) block first degree (26.7% vs 10.1%, P=.004); higher calcium volume of the left coronary cusp (63.1±87.5 mm(3) vs 42.8±49.3 mm(3), P=.05); and deeper valve implantation at right coronary (P=.011), noncoronary (P=.026), and left coronary (P=.012) position. Oversizing in relation to annulus and left ventricular outflow tract did not have an impact on need for PPMI. By multiple regression analysis, preprocedural AV block first degree (P=.005), RBBB (P<.001), and depth of implantation (P=.006) were independent risk factors for need of PPMI. In patients with severe aortic stenosis receiving transfemoral Lotus valve, preexisting AV block first degree, RBBB, and implantation depth are independent predictors of PPMI, highlighting the importance of careful valve positioning. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. 3D Printed Trileaflet Valve Conduits Using Biological Hydrogels and Human Valve Interstitial Cells

    OpenAIRE

    Duan, Bin; Kapetanovic, Edi; Hockaday, Laura A.; Butcher, Jonathan T.

    2013-01-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, 3D bioprinting enables deposition of cells and hydrogels into 3D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach is however constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not know...

  19. Characterization of Aortic Valve Closure Artifact During Outflow Tract Mapping: Correlation With Hemodynamics and Mechanical Valves.

    Science.gov (United States)

    Romero, Jorge; Ajijola, Olujimi; Shivkumar, Kalyanam; Tung, Roderick

    2017-06-01

    Premature ventricular contractions originating in the left ventricle outflow tract represent a significant subgroup of patients referred for catheter ablation. Mechanical artifacts from aortic valve leaflet motion may be observed during mapping, although the incidence and characteristics have not been reported. Twenty-eight consecutive patients with left ventricle outflow tract premature ventricular contraction were included. Electric signals recorded on the ablation catheter not coincident with atrial or ventricular depolarization were analyzed on the recording system. Correlation with invasive hemodynamic aortic pressure tracings was performed. Additionally, 4 patients with mechanical aortic valves, who underwent scar-related ventricular tachycardia ablation, were analyzed to correlate the timing of the observed artifacts with native aortic valves. Aortic valve artifact was observed while mapping within the coronary cusps in 11 patients (39%; 73% men; age, 41±25 years; left ventricular ejection fraction 49±16%) with high incidence from the left coronary cusp. This artifact was consistently observed with timing coincident with the terminal portion of the T wave. The average interval between the end of the T wave and the aortic valve artifact was 19±37 ms. The duration of the aortic valve artifact was 39±8 ms with amplitude of 0.12±0.07 mV (range, 0.06-0.36 mV). In patients referred for left ventricle outflow tract premature ventricular contraction ablation, an aortic valve closure artifact is observed in up to one third of cases during mapping within the aortic cusps. The timing of this artifact correlates with invasive hemodynamics and mechanical aortic valve artifacts. Recognition of this physiological phenomenon is useful when assigning near-field activation. © 2017 American Heart Association, Inc.

  20. The warm, rich sound of valve guitar amplifiers

    Science.gov (United States)

    Keeports, David

    2017-03-01

    Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier adds harmonics to an input sound. While a moderately overdriven valve amplifier produces strong even harmonics that enhance a sound, an overdriven transistor amplifier creates strong odd harmonics that can cause dissonance. The functioning of a triode valve explains its creation of even and odd harmonics. Music production software enables the examination of both the wave shape and the harmonic content of amplified sounds.

  1. Three-dimensional analysis of partially open butterfly valve flows

    Energy Technology Data Exchange (ETDEWEB)

    Huang, C.; Kim, R.H. [Univ. of North Carolina, Charlotte, NC (United States). Dept. of Mechanical Engineering and Engineering Science

    1996-09-01

    A numerical simulation of butterfly valve flows is a useful technique to investigate the physical phenomena of the flow field. A three-dimensional numerical analysis was carried out on incompressible fluid flows in a butterfly valve by using FLUENT, which solves difference equations. Characteristics of the butterfly valve flows at different valve disk angles with a uniform incoming velocity were investigated. Comparisons of FLUENT results with other results, i.e., experimental results, were made to determine the accuracy of the employed method. Results of the three-dimensional analysis may be useful in the valve design.

  2. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  3. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  4. Diaphragms in air-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Groeger, J.E.

    1996-12-01

    The author will present current issues related to diaphgrams in air-operated valves. Altran Materials Engineering, Inc., often performs root-cause analyses for nuclear power plant owners. The author will discuss various analyses that have been performed or are currently underway.

  5. Ventriculopleural shunting with new technology valves.

    Science.gov (United States)

    Martínez-Lage, J F; Torres, J; Campillo, H; Sanchez-del-Rincón, I; Bueno, F; Zambudio, G; Poza, M

    2000-12-01

    Ventriculoperitoneal shunting constitutes the standard procedure for draining cerebrospinal fluid (CSF) in children with hydrocephalus. Ventriculoatrial and ventriculopleural shunting are alternative methods of CSF drainage, which have gained less acceptance. Ventriculopleural shunts are seldom used owing to justified fears of pneumothorax and symptomatic effusions of CSF. The addition of an antisiphon device to standard shunt systems seems to have prevented CSF pleural effusion. From 1988 to 1998, we treated each of six hydrocephalic children with a ventriculopleural shunt. In five cases we used new-technology valves designed to prevent the effects of siphoning with current differential pressure valves. Peritoneal adhesions, recent peritonitis, ascites, and obstruction of a previous ventriculoatrial shunt were the indications for pleural shunting. After a mean follow-up period of 2.5 years all shunts were functioning adequately. Only one patient showed transient symptoms of CSF overdrainage, which were corrected by up-grading the valve setting with the magnet. A late death was unrelated to the pleural shunting procedure. The use of valves of a new design designed to prevent overdrainage seems to account for the satisfactory outcomes observed in this series. We suggest that ventriculopleural shunting should be considered as the preferred alternative to peritoneal drainage in children with intra-abdominal adhesions or with a history of recent peritoneal infection.

  6. Suspension suture techniques in nasal valve surgery

    NARCIS (Netherlands)

    Page, Meile S.; Menger, Dirk J.

    2011-01-01

    Impaired nasal breathing or collapse of the lateral side wall of the nasal valve region during inspiration is a frequently encountered symptom. In general, this is caused by a cross-sectional area that is too small, a weak lateral side wall, or a combination of both. Over the years, many techniques

  7. Differential Pressure Helps Seal Ball Valve

    Science.gov (United States)

    Mangialardi, J. K.

    1985-01-01

    Leakage suppressed despite O-ring wear. New design eliminates leakage in vacuum selector valve on Space Shuttle waste-control subsystem. Applied to improve sealing in laboratory and industrial vacuum systems and other plumbing involving switching among lines with pressure differentials of order of 1 atmosphere (0.1 MPa).

  8. Autopsy after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    van Kesteren, F; Wiegerinck, E M A; Rizzo, S

    2017-01-01

    Autopsy after transcatheter aortic valve implantation (TAVI) is a new field of interest in cardiovascular pathology. To identify the cause of death, it is important to be familiar with specific findings related to the time interval between the procedure and death. We aimed to provide an overview ...

  9. Potentially fatal tricuspid valve aspergilloma detected after ...

    African Journals Online (AJOL)

    Potentially fatal tricuspid valve aspergilloma detected after laparoscopic abdominal surgery. ... Aspergillus endocarditis is usually associated with high morbidity and mortality. ... The patient was successfully managed with emergency open-heart surgery and systemic antifungal agents in the postoperative period. Keywords: ...

  10. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, Lau Caspar

    2015-01-01

    age (hazard ratio (95% CI): 1.3 (1.0-1.6)), male sex (1.2 (1.0-1.5)), mitral valve surgery (1.3 (1.0-1.6)), and infective endocarditis after surgery (1.8 (1.1-3.0), p: 0.01) predicted readmission, whereas higher age (2.3 (1.0-5.4)), higher comorbidity score (3.2 (1.8-6.0)), and infective endocarditis......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12 months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n = 867). Participants completed a questionnaire regarding health-status (n = 742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...

  11. Minimally Invasive Mitral Valve Surgery III

    Science.gov (United States)

    Lehr, Eric J.; Guy, T. Sloane; Smith, Robert L.; Grossi, Eugene A.; Shemin, Richard J.; Rodriguez, Evelio; Ailawadi, Gorav; Agnihotri, Arvind K.; Fayers, Trevor M.; Hargrove, W. Clark; Hummel, Brian W.; Khan, Junaid H.; Malaisrie, S. Chris; Mehall, John R.; Murphy, Douglas A.; Ryan, William H.; Salemi, Arash; Segurola, Romualdo J.; Smith, J. Michael; Wolfe, J. Alan; Weldner, Paul W.; Barnhart, Glenn R.; Goldman, Scott M.; Lewis, Clifton T. P.

    2016-01-01

    Abstract Minimally invasive mitral valve operations are increasingly common in the United States, but robotic-assisted approaches have not been widely adopted for a variety of reasons. This expert opinion reviews the state of the art and defines best practices, training, and techniques for developing a successful robotics program. PMID:27662478

  12. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2011-03-01

    The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range.

  13. Antithrombotic therapy after bioprosthetic aortic valve implantation

    DEFF Research Database (Denmark)

    Rafiq, Sulman; Steinbrüchel, Daniel Andreas; Lilleør, Nikolaj Bang

    2017-01-01

    Background The optimal medical strategy for prevention of thromboembolic events after surgical bioprosthetic aortic valve replacement (BAVR) is still debated. The objective of this study was to compare warfarin therapy (target INR of 2.0 to 3.0) with aspirin 150 mg daily as antithrombotic therapy...

  14. Towards Performance Prognostics of a Launch Valve

    Science.gov (United States)

    2014-10-02

    Towards Performance Prognostics of a Launch Valve Glenn Shevach1, Mark Blair2, James Hing3, Larry Venetsky4, Everard Martin5, John Wheelock6...focuses on robotics and machine learning for ALRE & SE applications. Everard Martin is a Mechanical Engineer in the Steam Catapult Launcher In-Service

  15. Graphene spin valve: An angle sensor

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Zahir, E-mail: zahir.upc@gmail.com [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Hussain, Ghulam [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Siddique, Salma [Department of Bioscience & Biotechnology, Sejong University, Seoul 143-747 (Korea, Republic of); Iqbal, Muhammad Waqas [Department of Physics, Riphah Institute of Computing and Applied Sciences (RICAS), Riphah International University, Lahore (Pakistan)

    2017-06-15

    Graphene spin valves can be optimized for various spintronic applications by tuning the associated experimental parameters. In this work, we report the angle dependent magnetoresistance (MR) in graphene spin valve for different orientations of applied magnetic field (B). The switching points of spin valve signals show a clear shift towards higher B for each increasing angle of the applied field, thus sensing the response for respective orientation of the magnetic field. The angular variation of B shifts the switching points from ±95 G to ±925 G as the angle is varied from 0° to 90° at 300 K. The observed shifts in switching points become more pronounced (±165 G to ±1450 G) at 4.2 K for similar orientation. A monotonic increase in MR ratio is observed as the angle of magnetic field is varied in the vertical direction at 300 K and 4.2 K temperatures. This variation of B (from 0° to 90°) increases the magnitude of MR ratio from ∼0.08% to ∼0.14% at 300 K, while at 4.2 K it progresses to ∼0.39% from ∼0.14%. The sensitivity related to angular variation of such spin valve structure can be employed for angle sensing applications.

  16. Reed's Conjecture on hole expansions

    CERN Document Server

    Fouquet, Jean-Luc

    2012-01-01

    In 1998, Reed conjectured that for any graph $G$, $\\chi(G) \\leq \\lceil \\frac{\\omega(G) + \\Delta(G)+1}{2}\\rceil$, where $\\chi(G)$, $\\omega(G)$, and $\\Delta(G)$ respectively denote the chromatic number, the clique number and the maximum degree of $G$. In this paper, we study this conjecture for some {\\em expansions} of graphs, that is graphs obtained with the well known operation {\\em composition} of graphs. We prove that Reed's Conjecture holds for expansions of bipartite graphs, for expansions of odd holes where the minimum chromatic number of the components is even, when some component of the expansion has chromatic number 1 or when a component induces a bipartite graph. Moreover, Reed's Conjecture holds if all components have the same chromatic number, if the components have chromatic number at most 4 and when the odd hole has length 5. Finally, when $G$ is an odd hole expansion, we prove $\\chi(G)\\leq\\lceil\\frac{\\omega(G)+\\Delta(G)+1}{2}\\rceil+1$.

  17. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  18. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  19. The Use of Stepper Motor-Controlled Proportional Valve for Fio2Calculation in the Ventilator and its Control with Fuzzy Logic.

    Science.gov (United States)

    Gölcük, Adem; Güler, İnan

    2017-01-01

    This article proposes the employment of a proportional valve that can calculate the amount of oxygen in the air to be given to patient in accordance with the amount of FiO 2 which is set from the control menu of the ventilation device. To actualize this, a stepper motor-controlled proportional valve was used. Two counts of valves were employed in order to control the gases with 2 bar pressure that came from both the oxygen and medical air tanks. Oxygen and medical air manometers alongside the pressure regulators were utilized to perform this task. It is a fuzzy-logic-based controller which calculates at what rate the proportional valves will be opened and closed for FiO 2 calculation. Fluidity and pressure of air given by the ventilation device were tested with a FlowMeter while the oxygen level was tested using the electronic lung model. The obtained results from the study revealed that stepper motor controlled proportional valve could be safely used in ventilation devices. In this article, it was indicated that fluidity and pressure control could be carried out with just two counts of proportional valve, which could be done with many solenoid valves, so this reduces the cost of ventilator, electrical power consumed by the ventilator, and the dimension of ventilator.

  20. Vorticity dynamics of a bileaflet mechanical heart valve in an axisymmetric aorta

    Science.gov (United States)

    Dasi, L. P.; Ge, L.; Simon, H. A.; Sotiropoulos, F.; Yoganathan, A. P.

    2007-06-01

    We present comprehensive particle image velocimetry measurements and direct numerical simulation (DNS) of physiological, pulsatile flow through a clinical quality bileaflet mechanical heart valve mounted in an idealized axisymmetric aorta geometry with a sudden expansion modeling the aortic sinus region. Instantaneous and ensemble-averaged velocity measurements as well as the associated statistics of leaflet kinematics are reported and analyzed in tandem to elucidate the structure of the velocity and vorticity fields of the ensuing flow-structure interaction. The measurements reveal that during the first half of the acceleration phase, the flow is laminar and repeatable from cycle to cycle. The valve housing shear layer rolls up into the sinus and begins to extract vorticity of opposite sign from the sinus wall. A start-up vortical structure is shed from the leaflets and is advected downstream as the leaflet shear layers become wavy and oscillatory. In the second half of flow acceleration the leaflet shear layers become unstable and break down into two von Karman-like vortex streets. The onset of vortex shedding from the valve leaflets is responsible for the growth of significant cycle-to-cycle vorticity oscillations. At peak flow, the housing and leaflet shear layers undergo secondary instabilities and break down rapidly into a chaotic, turbulent-like state with multiple small-scale vortical structures emerging in the flow. During the deceleration and closing phases all large-scale coherent flow features disappear and a chaotic small-scale vorticity field emerges, which persists even after the valve has closed. Probability density functions of the leaflet position during opening and closing phases show that the leaflet position fluctuates from cycle to cycle with larger fluctuations evident during valve closure. The DNS is carried out by prescribing the leaflet kinematics from the experimental data. The computed instantaneous vorticity fields are in very good

  1. Hybrid textile heart valve prosthesis: preliminary in vitro evaluation.

    Science.gov (United States)

    Vaesken, Antoine; Pidancier, Christian; Chakfe, Nabil; Heim, Frederic

    2016-09-22

    Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.

  2. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2015-12-15

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles.

  3. Numerical Analysis for Structural Safety Evaluation of Butterfly Valves

    Science.gov (United States)

    Shin, Myung-Seob; Yoon, Joon-Yong; Park, Han-Yung

    2010-06-01

    Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low operating pressure especially in large size pipelines. For the industrial application of butterfly valves, it must be ensured that the valve could be used safety under the fatigue life and the deformations produced by the pressure of the fluid. In this study, we carried out the structure analysis of the body and the valve disc of the butterfly valve and the numerical simulation was performed by using ANSYS v11.0. The reliability of valve is evaluated under the investigation of the deformation, the leak test and the durability of the valve.

  4. Theoretical analysis of steady state operating forces in control valves

    Directory of Open Access Journals (Sweden)

    Basavaraj Hubballi

    2018-01-01

    Full Text Available The controlling components, such as valves are used to regulate controlled fluid power. It is not always possible to calculate valve forces accurately, and with some types of valves even the existence of certain types of forces cannot be predicted with certainty. In many cases, however, the analysis can be made fairly completely and accurately. The assumption of steady state conditions is valid for the valve alone, but transient effects in the rest of the system may be large. These effects are particularly important with regard to the instability of valves, where the system may react on the valve in such a way as to make it squeal or oscillate, sometimes with large amplitude. The origin of the steady state flow force understood from a brief qualitative explanation. The following paper will summarize much of what is known about valve forces in the spool type controlling element.

  5. Fluid-structure interaction of an aortic heart valve prosthesis driven by an animated anatomic left ventricle

    Science.gov (United States)

    Le, Trung Bao; Sotiropoulos, Fotis

    2013-07-01

    We develop a novel large-scale kinematic model for animating the left ventricle (LV) wall and use this model to drive the fluid-structure interaction (FSI) between the ensuing blood flow and a mechanical heart valve prosthesis implanted in the aortic position of an anatomic LV/aorta configuration. The kinematic model is of lumped type and employs a cell-based, FitzHugh-Nagumo framework to simulate the motion of the LV wall in response to an excitation wavefront propagating along the heart wall. The emerging large-scale LV wall motion exhibits complex contractile mechanisms that include contraction (twist) and expansion (untwist). The kinematic model is shown to yield global LV motion parameters that are well within the physiologic range throughout the cardiac cycle. The FSI between the leaflets of the mechanical heart valve and the blood flow driven by the dynamic LV wall motion and mitral inflow is simulated using the curvilinear immersed boundary (CURVIB) method (Ge and Sotiropoulos, 2007; Borazjani et al., 2008) [1,2] implemented in conjunction with a domain decomposition approach. The computed results show that the simulated flow patterns are in good qualitative agreement with in vivo observations. The simulations also reveal complex kinematics of the valve leaflets, thus, underscoring the need for patient-specific simulations of heart valve prosthesis and other cardiac devices.

  6. Double orifice mitral valve: A case report

    Directory of Open Access Journals (Sweden)

    Musić Ljilja

    2016-01-01

    Full Text Available Introduction. Double orifice mitrol valve (DOMV is a very rare congenital heart defect. Case report. We reported 20-year-old male referred to our center due to evaluation of his cardiologic status. He was operated on shortly after birth for a tracheoesophageal fistula. Accidentally, echocardiography examination at the age of 4 years revealed double orifice mitral valve (DOMV without the presence of mitral regurgitation, as well as mitral stenosis, with normal dimensions of all cardiac chambers. The patient was asymptomatic, even more he was a kick boxer. His physical finding was normal. Electrocardiography showed regular sinus rhythm, incomplete right bundle branch block. Transthoracic echocardiography (TTE examination revealed the normal size of the left atrial, mitral leaflets were slightly more redundant. The left and right heart chambers, aorta, tricuspid valve and pulmonary artery valve were normal. During TTE examination on a short axis view two asymmetric mitral orifices were seen as a double mitral orifice through which we registered normal flow, without regurgitation and mitral stenosis. Transesophageal echocardiography (TEE examination from the transgastric view at the level of mitral valve, showed 2 single asymmetric mitral orifices separated by fibrous tissue, mitral leaflet with a separate insertion of hordes for each orifice. Conclusion. The presented patient with DOMV is the only one recognized in our country. The case is interesting because during 16-year a follow-up period there were no functional changes despite the fact that he performed very demanded sport activities. This is very important because there is no information in the literature about that.

  7. Low thermal expansion glass ceramics

    CERN Document Server

    1995-01-01

    This book is one of a series reporting on international research and development activities conducted by the Schott group of companies With the series, Schott aims to provide an overview of its activities for scientists, engineers, and managers from all branches of industry worldwide where glasses and glass ceramics are of interest Each volume begins with a chapter providing a general idea of the current problems, results, and trends relating to the subjects treated This volume describes the fundamental principles, the manufacturing process, and applications of low thermal expansion glass ceramics The composition, structure, and stability of polycrystalline materials having a low thermal expansion are described, and it is shown how low thermal expansion glass ceramics can be manufactured from appropriately chosen glass compositions Examples illustrate the formation of this type of glass ceramic by utilizing normal production processes together with controlled crystallization Thus glass ceramics with thermal c...

  8. Low Thermal Expansion Glass Ceramics

    CERN Document Server

    Bach, Hans

    2005-01-01

    This book appears in the authoritative series reporting the international research and development activities conducted by the Schott group of companies. This series provides an overview of Schott's activities for scientists, engineers, and managers from all branches of industry worldwide in which glasses and glass ceramics are of interest. Each volume begins with a chapter providing a general idea of the current problems, results, and trends relating to the subjects treated. This new extended edition describes the fundamental principles, the manufacturing process, and applications of low thermal expansion glass ceramics. The composition, structure, and stability of polycrystalline materials having a low thermal expansion are described, and it is shown how low thermal expansion glass ceramics can be manufactured from appropriately chosen glass compositions. Examples illustrate the formation of this type of glass ceramic by utilizing normal production processes together with controlled crystallization. Thus g...

  9. Thermal Expansion of Hafnium Carbide

    Science.gov (United States)

    Grisaffe, Salvatore J.

    1960-01-01

    Since hafnium carbide (HfC) has a melting point of 7029 deg. F, it may have many high-temperature applications. A literature search uncovered very little information about the properties of HfC, and so a program was initiated at the Lewis Research Center to determine some of the physical properties of this material. This note presents the results of the thermal expansion investigation. The thermal-expansion measurements were made with a Gaertner dilatation interferometer calibrated to an accuracy of +/- 1 deg. F. This device indicates expansion by the movement of fringes produced by the cancellation and reinforcement of fixed wave-length light rays which are reflected from the surfaces of two parallel quartz glass disks. The test specimens which separate these disks are three small cones, each approximately 0.20 in. high.

  10. Repeated expansion in burn sequela.

    Science.gov (United States)

    Pitanguy, Ivo; Gontijo de Amorim, Natale Ferreira; Radwanski, Henrique N; Lintz, José Eduardo

    2002-08-01

    This paper presents a retrospective study of the use of 346 expanders in 132 patients operated at the Ivo Pitanguy Clinic, between the period of 1985 and 2000. The expanders were used in the treatment of burn sequela. In the majority of cases, more than one expander was used at the same time. In 42 patients, repeated tissue expansion was done. The re-expanded flaps demonstrated good distension and viability. With the increase in area at each new expansion, larger volume expanders were employed, achieving an adequate advancement of the flaps to remove the injured tissue. The great advantage of using tissue re-expansion in the burned patient is the reconstruction of extensive areas with the same color and texture of neighboring tissues, without the addition of new scars.

  11. Langmuir probe study of plasma expansion in pulsed laser ablation

    DEFF Research Database (Denmark)

    Hansen, T.N.; Schou, Jørgen; Lunney, J.G.

    1999-01-01

    Langmuir probes were used to monitor the asymptotic expansion of the plasma produced by the laser ablation of a silver target in a vacuum. The measured angular and temporal distributions of the ion flux and electron temperature were found to be in good agreement with the self-similar isentropic a...... and adiabatic solution of the gas dynamics equations describing the expansion. The value of the adiabatic index gamma was about 1.25, consistent with the ablation plume being a low temperature plasma....

  12. Expansion coefficients of scattering parameters in quantum thermodynamic perturbation theory

    Energy Technology Data Exchange (ETDEWEB)

    Buendia, E.; Guardiola, R. (Departamento de Fisica Moderna, Universidad de Granada Granada, Spain, 18071 (ES)); De Llano, M. (Physics Department, North Dakota State University, Fargo, North Dakota 58105)

    1989-07-01

    We tabulate the expansion coefficients of various scattering parameters associated with several interparticle pair potentials used in the quantum thermodynamic perturbation theory of strongly coupled, many-particle substances. The expansion is in powers or the attractive part of the pair potential. The potential is divided into repulsive and attractive parts according to several methods in vogue both in classical and in quantum equation-of-state studies of condensed-matter systems. Results are reported for several interparticle potentials of helium-3 and -4 atoms, of the three electron spin-polarized isotopes of atomic hydrogen, and of the nucleon.

  13. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mell, Ellen [Aerovalve, LLC, St. Louis, Mo (United States)

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  14. Performance evaluation of ejector expansion combined cooling and power cycles

    Science.gov (United States)

    Ghaebi, Hadi; Rostamzadeh, Hadi; Matin, Pouria Seyed

    2017-09-01

    This paper studies performance characteristics of a basic ejector expansion combined cooling and power cycle (EECCPC) as well as three modified ones. These modified cycles are EECCPC incorporating turbine bleeding, regenerative EECCP cycle, and EECCP cycle incorporating with both turbine bleeding and regeneration. The expansion valve has been replaced by a two-phase ejector-expander in the traditional CCP cycle to improve the first and second-law efficiencies. Furthermore, the exergy destruction for components of the systems as well as the whole systems has been calculated, leading to determination of the main source of irreversibility in different cycles. The results of the exergy analysis reveals that the generator has the major contribution role in the overall losses of the systems. The results also show that the EECCP cycle surpasses the TCCP cycle in terms of thermal and exergy efficiencies. As a matter of fact, the thermal and exergy efficiencies are improved by 6.02, and 5.44%, respectively, throughout this successive modification. At last, sensitivity analysis of different key parameters on performance of the cycles has been investigated. It is shown that one can obtain higher thermal efficiency by increasing of the generator and evaporator temperatures or decreasing of the condenser temperature.

  15. 18 CFR 154.309 - Incremental expansions.

    Science.gov (United States)

    2010-04-01

    ... Changes § 154.309 Incremental expansions. (a) For every expansion for which incremental rates are charged... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Incremental expansions... incremental facilities to be rolled-in to the pipeline's rates. For every expansion that has an at-risk...

  16. Collisionless plasma expansion into vacuum: Two new twists on an old problema)

    Science.gov (United States)

    Arefiev, Alexey V.; Breizman, Boris N.

    2009-05-01

    The paper deals with a generic problem of collisionless plasma expansion into vacuum in the regimes where the expanding plasma consists of hot electrons and cold ions. The expansion is caused by electron pressure and serves as an energy transfer mechanism from electrons to ions. This process is often described under the assumption of Maxwellian electrons, which easily fails in the absence of collisions. The paper discusses two systems with a naturally occurring non-Maxwellian distribution: an expanding laser-irradiated nanoplasma and a supersonic jet coming out of a magnetic nozzle. The presented rigorous kinetic description demonstrates how the deviation from the Maxwellian distribution fundamentally alters the process of ion acceleration during plasma expansion. This result points to the critical importance of a fully kinetic treatment in problems with collisionless plasma expansion.

  17. Low-thermal expansion infrared glass ceramics

    Science.gov (United States)

    Lam, Philip

    2009-05-01

    L2 Tech, Inc. is in development of an innovative infrared-transparent glass ceramic material with low-thermal expansion (ZrW2O8) which has Negative Thermal Expansion (NTE). The glass phase is the infrared-transparent germanate glass which has positive thermal expansion (PTE). Then glass ceramic material has a balanced thermal expansion of near zero. The crystal structure is cubic and the thermal expansion of the glass ceramic is isotropic or equal in all directions.

  18. How Heart Valves Evolve to Adapt to an Extreme-Pressure System: Morphologic and Biomechanical Properties of Giraffe Heart Valves.

    Science.gov (United States)

    Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik; Martin Bibby, Bo; Carl Andelius, Ted; Toft Brøndum, Emil; Wang, Tobias; Michael Hasenkam, J

    2017-01-01

    Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid in developing techniques to design improved pressure-resistant biological heart valves. Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations. The aortic valve was shown to be 70% (95% CI 42-103%) stronger in the giraffe than in its bovine counterpart (p giraffe aortic valve was found to be significantly stiffer than the bovine aortic valve (p giraffes contained significantly more collagen than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength, stiffness, and collagen content.

  19. Suppression of runaway electron generation by massive helium injection after induced disruptions on TEXTOR

    Science.gov (United States)

    Lvovskiy, A.; Koslowski, H. R.; Zeng, L.

    2015-10-01

    > Disruptions with runaway electron generation have been deliberately induced by injection of argon using a disruption mitigation valve. A second disruption mitigation valve has been utilised to inject varying amounts of helium after a short time delay. No generation of runaway electrons has been observed when more than a critical amount of helium has been injected no later than 5 ms after the triggering of the first valve. The required amount of helium for suppression of runaway electron generation is up to one order of magnitude lower than the critical density according to Connor & Hastie (1975) and Rosenbluth & Putvinski (1997).

  20. St Jude Epic heart valve bioprostheses versus native human and porcine aortic valves - comparison of mechanical properties.

    Science.gov (United States)

    Kalejs, Martins; Stradins, Peteris; Lacis, Romans; Ozolanta, Iveta; Pavars, Janis; Kasyanov, Vladimir

    2009-05-01

    The major problem with heart valve bioprostheses made from chemically treated porcine aortic valves is their limited longevity caused by gradual deterioration, which has a causal link with valve tissue mechanical properties. To our best knowledge, there are no published studies on the mechanical properties of modern, commercially available bioprostheses comparing them to native human valves. The objective of this study is to determine the mechanical properties of St Jude Epic bioprostheses and to compare them with native human and porcine aortic valves. Leaflets from eight porcine aortic valves and six Epic bioprostheses were analyzed using uni-axial tensile tests in radial and circumferential directions. Mechanical properties of human valves have been previously published by our group. Results are represented as mean values+/-S.D. Circumferential direction. Modulus of elasticity of Epic bioprostheses in circumferential direction at the level of stress 1.0 MPa is 101.99+/-58.24 MPa, 42.3+/-4.96 MPa for native porcine and 15.34+/-3.84 MPa for human aortic valves. Ultimate stress is highest for Epic bioprostheses 5.77+/-1.94 MPa, human valves have ultimate stress of 1.74+/-0.29 MPa and porcine 1.58+/-0.26 MPa. Ultimate strain in circumferential direction is highest for human valves 18.35+/-7.61% followed by 7.26+/-0.69% for porcine valves and 5.95+/-1.54% for Epic bioprostheses. Radial direction. Modulus of elasticity in radial direction is 9.18+/-1.81 MPa for Epic bioprostheses, 5.33+/-0.61 MPa for native porcine, and 1.98+/-0.15 MPa for human aortic valve leaflets. In the radial direction ultimate stress is highest for Epic bioprostheses 0.7+/-0.21 MPa followed by native porcine valves 0.55+/-0.11 MPa and 0.32+/-0.04 MPa for human valves. For human valves ultimate strain is 23.92+/-4.87%, for native porcine valves 8.57+/-0.8% and 7.92+/-1.74% for Epic bioprostheses. Epic bioprostheses have non-linear stress-strain behavior similar to native valve tissue, but they