WorldWideScience

Sample records for electronic acquisition system

  1. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  2. The LHCb front-end electronics and data acquisition system

    CERN Document Server

    Jost, B

    2000-01-01

    The LHCb experiment is the most recently approved of the four experiments under construction at CERN's LHC accelerator. It is a special purpose experiment designed to precisely measure the CP violation parameters in the B-B system and to study rare B-decays. Triggering poses special problems since the interesting events containing B-mesons are immersed in a large background of inelastic p-p reactions. We therefore decided to implement a four-level triggering scheme. The LHCb data acquisition (DAQ) system will have to cope with an average trigger rate of 40 kHz, after two levels of hardware triggers, and an average event size of 100 kB. Thus, an event-building network which can sustain an average bandwidth of 4 GB /s is required. A powerful software trigger farm will have to be installed to reduce the rate from 40 kHz to 100 Hz of events written for permanent storage. In this paper we will outline the general architectures of the front-end electronics and of the trigger and DAQ system and the readout protocols...

  3. Data acquisition system for the Pelletron electron accelerator

    International Nuclear Information System (INIS)

    Flores E, O.

    1997-01-01

    In this work, a system is developed that allows to know and view of immediate manner the conditions occurred during the operation of the Pelletron. This is carried out by means of the design of a data acquisition system which displays in graphic form, in the screen of a computer, the operation conditions like pressure of the tank, current of the electron beam, voltage in the inductors of the elctrostatic generator, level of produced radiation, etc., all of this parameters determine the behavior of the accelerator. The hardware of the system includes the design and construction of conditioning and transmission circuits used to send the information to an interface board that allows th communication between the analog world and the computer. In this case, the utilized board is the AT-MIO-16L-25, that is a high-performance multifunction analog, digital and timing input/output (I/O) board for the IBM PC/AT and compatibles. The software implicates the design of the necessary programs to manipulate the interface board, for the processing and presentation of information in the screen of the computer and also for the storage of the acquired data in a permanent medium. In this case, a relatively new tool, known like Virtual instrumentation is utilized. Concretely, the LabVIEW programming software package is used (Laboratory Virtual Instrument Engineering Workbench), which is designed for applications in instrumentation and control. This programming package gives the necessary elements for the analysis and processing of the acquired data. The system is developed in base to the requirements done for the users and designers of the Pelletron. (Author)

  4. Development of electronics and data acquisition system for independent calibration of electron cyclotron emission radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, Praveena, E-mail: praveena@ipr.res.in; Raulji, Vismaysinh; Mandaliya, Hitesh; Patel, Jignesh; Siju, Varsha; Pathak, S.K.; Rajpal, Rachana; Jha, R.

    2016-11-15

    Highlights: • Indigenous development of an electronics and data acquisition system to digitize signals for a desired time and automatization of calibration process. • 16 bit DAQ board with form factor of 90 × 89 mm. • VHDL Codes written for generating control signals for PC104 Bus, ADC and RAM. • Averaging process is done in two ways single point averaging and additive averaging. - Abstract: Signal conditioning units (SCU) along with Multichannel Data acquisition system (DAS) are developed and installed for automatization and frequent requirement of absolute calibration of ECE radiometer system. The DAS is an indigenously developed economical system which is based on Single Board Computer (SBC). The onboard RAM memory of 64 K for each channel enables the DAS for simultaneous and continuous acquisition. A Labview based graphical user interface provides commands locally or remotely to acquire, process, plot and finally save the data in binary format. The microscopic signals received from radiometer are strengthened, filtered by SCU and acquired through DAS for the set time and at set sampling frequency. Stored data are processed and analyzed offline with Labview utility. The calibration process has been performed for two hours continuously at different sampling frequency (100 Hz to 1 KHz) at two set of temperature like hot body and the room temperature. The detailed hardware and software design and testing results are explained in the paper.

  5. The data acquisition system used in one-dimension multichannel fast electron energy loss spectrometer

    International Nuclear Information System (INIS)

    Jiang Weichun; Zhu Linfan; Zhang Yijun; Xu Kezuo

    2010-01-01

    It describes a data acquisition system used in one dimension multichannel fast electron energy loss spectrometer, which can work in scan acquisition mode and static acquisition mode. The timing precision of the scan mode is less than 4 μs by utilizing the gated signal generated by data acquisition card DAQ2010 and an AND logic circuit. A timer card PCI8554 is used to synchronize the data acquisition card and the personal computer. The scan voltage supply is controlled by the personal computer through the RS232 interface. The multithreading technology is used in the acquisition software in order to improve the accommodating-err ability of the acquisition system. A satisfactory test result is given. (authors)

  6. 75 FR 65439 - Defense Federal Acquisition Regulation Supplement; Electronic Subcontracting Reporting System

    Science.gov (United States)

    2010-10-25

    ... Accounting Service or Missile Defense Agency. (2) For DoD, the authority to acknowledge receipt or reject... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Parts 219 and 252 [DFARS Case 2009-D002] Defense Federal Acquisition Regulation Supplement; Electronic Subcontracting Reporting...

  7. An asynchronous, pipelined, electronic acquisition system for Active Matrix Flat-Panel Imagers (AMFPIs)

    CERN Document Server

    Huang, W; Berry, J; Maolinbay, M; Martelli, C; Mody, P; Nassif, S; Yeakey, M

    1999-01-01

    The development of a full-custom electronic acquisition system designed for readout of large-area active matrix flat-panel imaging arrays is reported. The arrays, which comprise two-dimensional matrices of pixels utilizing amorphous silicon thin-film transistors, are themselves under development for a wide variety of X-ray imaging applications. The acquisition system was specifically designed to facilitate detailed, quantitative investigations of the properties of these novel imaging arrays and contains significant enhancements compared to a previously developed acquisition system. These enhancements include pipelined preamplifier circuits to allow faster readout speed, expanded addressing capabilities allowing a maximum of 4096 array data lines, and on-board summing of image frames. The values of many acquisition system parameters, including timings and voltages, may be specified and downloaded from a host computer. Once acquisition is enabled, the system operates asynchronously of its host computer. The sys...

  8. Electronics engineering tools for modern data acquisition systems

    International Nuclear Information System (INIS)

    Cardoso, Guilherme; Kwan, Simon; Vergara, Sergio; Sheaff, Marleigh

    2003-01-01

    The very large number of channels and high data rates in modern particle physics experiments put very stringent requirements on the acquisition of data. To reduce the cost as well as the number of cables required to transport the data from detector to counting room, it is necessary to use very large scale integrated circuits for pre-processing the data right on the front-end circuit boards. Also, very high speed optoelectronic circuits are needed to transport the data on to the counting room from the front-end circuits. Two techniques relevant to data acquisition are discussed. The first is Field Programmable Gate Arrays (FPGAs), including using the Very High Speed Integrated Circuit Hardware Description Language (VHDL) to program them. The second is the design of a very high speed optoelectronic circuit for data transport

  9. Electronic drive and acquisition system for mass spectrometry

    Science.gov (United States)

    Schaefer, Rembrandt Thomas (Inventor); Mojarradi, Mohammad (Inventor); Chutjian, Ara (Inventor); Darrach, Murray R. (Inventor); MacAskill, John (Inventor); Tran, Tuan (Inventor); Burke, Gary R. (Inventor); Madzunkov, Stojan M. (Inventor); Blaes, Brent R. (Inventor); Thomas, John L. (Inventor)

    2010-01-01

    The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.

  10. Microprocessor system for data acquisition processing and display for Auger electrons spectrometer

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Cudny, W.; Hildebrandt, S.; Marzec, J.; Walentek, J.; Zaremba, K.

    1984-01-01

    Data acquisition system for Auger electron spectrometry is developed. The system is used for chemical and structural analysis of materials and consists of a cylindrical mirror analyzer being a measuring spectrometer device, CAMAC unit and control unit. The control unit comprises a microcomputer based on INTEL 8080 microprocessor and display

  11. Data acquisition system for electronic paramagnetic resonance spectrophotometer

    International Nuclear Information System (INIS)

    Pena Eguiluz, R.

    1992-01-01

    In the Atomic and Molecular Physics Laboratory at the Physics Department of the Instituto Nacional de Investigaciones Nucleares (ININ), there is in operation an electronic paramagnetic resonance spectrometer (EPR). This equipment is utilized for determine, the distribution of the absorbed energy intensity for a sample of paramagnetic substance by means of the study and analysis of its emission lines spectrum. The useful information is provided as a graphic result showing the spectrum corresponding to the analyzed sample. In similar devices like this, the researchers problem, trying to get the important information, is a hard and imprecise work, thus, this process of find the ordinate magnitudes of a approximately two hundred points, equal spaced in the spectrum, is carried out completely by hand. After this, the information is captured and processed in a personal computer. As a solution for this problem, an interface in both aspects, hardware and software adaptable to a personal computer, was designed and constructed. This interface is able to: a) To get and digitized the analogical signal, that represents the corresponding spectrum curve. b) It stores the digitized information in files and c) It displays in graphic mode the stored data, and then these are normalized in order to be transferred to a statistics and analytical software packets (Author)

  12. Application of a digital data acquisition system for time of flight Positron annihilation-induced Auger Electron Spectroscopy

    Science.gov (United States)

    Gladen, R. W.; Chirayath, V. A.; McDonald, A. D.; Fairchild, A. J.; Chrysler, M. D.; Imam, S. K.; Koymen, A. R.; Weiss, A. H.

    We describe herein a digital data acquisition system for a time-of-flight Positron annihilation-induced Auger Electron Spectrometer. This data acquisition system consists of a high-speed digitizer collecting signals induced by Auger electrons and annihilation gammas in a multi-channel plate electron detector and a BaF2 gamma detector, respectively. The time intervals between these two signals is used to determine the times of flight of the Auger electrons, which are analyzed by algorithms based on traditional nuclear electronics methods. Ultimately, this digital data acquisition system will be expanded to incorporate the first coincidence measurements of Auger electron and annihilation gamma energies.

  13. Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak

    International Nuclear Information System (INIS)

    Kim, J. B.; Lee, W.; Yun, G. S.; Park, H. K.; Domier, C. W.; Luhmann, N. C. Jr.

    2010-01-01

    A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment.

  14. An asynchronous, pipelined, electronic acquisition system for Active Matrix Flat-Panel Imagers (AMFPIs)

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W.; Antonuk, L.E. E-mail: antonuk@umich.edu; Berry, J.; Maolinbay, M.; Martelli, C.; Mody, P.; Nassif, S.; Yeakey, M

    1999-07-11

    The development of a full-custom electronic acquisition system designed for readout of large-area active matrix flat-panel imaging arrays is reported. The arrays, which comprise two-dimensional matrices of pixels utilizing amorphous silicon thin-film transistors, are themselves under development for a wide variety of X-ray imaging applications. The acquisition system was specifically designed to facilitate detailed, quantitative investigations of the properties of these novel imaging arrays and contains significant enhancements compared to a previously developed acquisition system. These enhancements include pipelined preamplifier circuits to allow faster readout speed, expanded addressing capabilities allowing a maximum of 4096 array data lines, and on-board summing of image frames. The values of many acquisition system parameters, including timings and voltages, may be specified and downloaded from a host computer. Once acquisition is enabled, the system operates asynchronously of its host computer. The system allows image capture in both radiographic mode (corresponding to the capture of individual X-ray images), and fluoroscopic mode (corresponding to the capture of a continual series of X-ray images). A detailed description of the system architecture and the underlying motivations for the design is reported in this paper. (author)

  15. The System of Public Acquisitions by Means of Electronic Bids in the Light of European Regulations

    Directory of Open Access Journals (Sweden)

    Costantin Roman

    2007-01-01

    Full Text Available E-commerce can lead in many different ways to cost reduction in case of a supplier and can subsequently increase the competition potential of a company. As for the competition mechanism, such changes produce significant modifications within a market economy. The Internet renders the possibility of creating business contacts in a rapid and geographically independent manner, as well as possibilities of obtaining data and realizing transactions within the world’s economy. Public acquisitions by means of dynamic systems and electronic bids are currently one of the significant areas of electronic commerce.

  16. Design and implementation of electronics and data acquisition system for Ultra-Fast Flash Observatory

    DEFF Research Database (Denmark)

    Jung, A.; Ahmad, S.; Barrillon, P.

    2013-01-01

    . UBAT is equipped with an X-ray detector, analog and digital signal readout electronics that detects X-rays from GRBs and determines the location. SMT is equipped with a stepping motor and the associated electronics to rotate the slewing mirror targeting the GRBs identified by UBAT. First the slewing...... mirror points to a GRB, then SMT obtains the optical image of the GRB using the intensified CCD and its readout electronics. The UFFO Data Acquisition system (UDAQ) is responsible for the overall function and operation of the observatory and the communication with the satellite main processor....... In this paper we present the design and implementation of the electronics of UBAT and SMT as well as the architecture and implementation of UDAQ....

  17. Using VME to leverage legacy CAMAC electronics into a high speed data acquisition system

    International Nuclear Information System (INIS)

    Anthony, P.L.

    1997-06-01

    The authors report on the first full scale implementation of a VME based Data Acquisition (DAQ) system at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the End Station A (ESA) fixed target program. It was designed to handle interrupts at rates up to 120 Hz and event sizes up to 10,000 bytes per interrupt. One of the driving considerations behind the design of this system was to make use of existing CAMAC based electronics and yet deliver a high performance DAQ system. This was achieved by basing the DAQ system in a VME backplane allowing parallel control and readout of CAMAC branches and VME DAQ modules. This system was successfully used in the Spin Physics research program at SLAC (E154 and E155)

  18. MPS Data Acquisition System

    International Nuclear Information System (INIS)

    Eiseman, S.E.; Miller, W.J.

    1975-01-01

    A description is given of the data acquisition system used with the multiparticle spectrometer facility at Brookhaven. Detailed information is provided on that part of the system which connects the detectors to the data handler; namely, the detector electronics, device controller, and device port optical isolator

  19. The Electronics and Data Acquisition System of the DarkSide Dark Matter Search

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P.; et al.

    2014-12-09

    It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.

  20. An Analysis of Electronic Commerce Acquisition Systems: Comparison of a New Pure Electronic Purchasing and Exchange System (Electronic Storefront) and Other Legacy On-line Purchasing Systems

    National Research Council Canada - National Science Library

    Rowe, Arthur

    2002-01-01

    ... as they relate to contracting and purchasing of supplies and services, The issues and concerns with legacy on-line procurement systems will be compared to a newly developed Pure Electronic Ordering System...

  1. Calo trigger acquisition system

    CERN Multimedia

    Franchini, Matteo

    2016-01-01

    Calo trigger acquisition system - Evolution of the acquisition system from a multiple boards system (upper, orange cables) to a single board one (below, light blue cables) where all the channels are collected in a single board.

  2. Flexible data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Clout, P N; Ridley, P A [Science Research Council, Daresbury (UK). Daresbury Lab.

    1978-06-01

    A data acquisition system has been developed which enables several independent experiments to be controlled by a 24 K word PDP-11 computer. Significant features of the system are the use of CAMAC, a high level language (RTL/2) and a general-purpose operating system executive which assist the rapid implementation of new experiments. This system has been used successfully for EXAFS and photo-electron spectroscopy experiments. It is intended to provide powerful concurrent data analysis and feedback facilities to the experimenter by on-line connection to the central IBM 370/165 computer.

  3. Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

    International Nuclear Information System (INIS)

    Alves de Oliveira, Juliano; Assis de Melo, Marco Antônio; Guazzelli da Silveira, Marcilei A.; Medina, Nilberto H.

    2014-01-01

    In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray

  4. Acquisition of electrical signals using commercial electronic components for detection system of Lead ion in distilled water

    Science.gov (United States)

    Pujiyanto; Yasin, M.; Rusydi, F.

    2018-03-01

    Development of lead ion detection systems is expected to have an advantage in terms of simplicity of the device and easy for concentration analysis of a lead ion with very high performance. One important part of lead ion detection systems are electrical signal acquisition parts. The electrical signal acquisition part uses the main electronic components: non inverting op-amplifier, instrumentation amplifier, multiplier circuit and logarithmic amplifier. Here will be shown the performance of lead ion detection systems when the existing electrical signal processors use commercial electronic components. The results that can be drawn from this experimental were the lead ion sensor that has been developed can be used to detect lead ions with a sensitivity of 10.48 mV/ppm with the linearity 97.11% and had a measurement range of 0.1 ppm to 80 ppm.

  5. The Lean Acquisition Strategy Behind the DOD’s 2015 Electronic Health Record System

    Science.gov (United States)

    2016-09-01

    the acquisition of CHCS, numerous errors caused delays in system development contracting. First, the DOD miscommunicated with some vendors and...Unsolidified program milestones Manager Lack of commitment Program focus on home-grown solutions 3. Question 2: What Were the Key Obstacles and Risks...differences in a way … solutions are presented” (personal communication, June 10, 2016). Program manager 1 echoes the findings from the survey that the

  6. Data-acquisition systems

    International Nuclear Information System (INIS)

    Cyborski, D.R.; Teh, K.M.

    1995-01-01

    Up to now, DAPHNE, the data-acquisition system developed for ATLAS, was used routinely for experiments at ATLAS and the Dynamitron. More recently, the Division implemented 2 MSU/DAPHNE systems. The MSU/DAPHNE system is a hybrid data-acquisition system which combines the front-end of the Michigan State University (MSU) DA system with the traditional DAPHNE back-end. The MSU front-end is based on commercially available modules. This alleviates the problems encountered with the DAPHNE front-end which is based on custom designed electronics. The first MSU system was obtained for the APEX experiment and was used there successfully. A second MSU front-end, purchased as a backup for the APEX experiment, was installed as a fully-independent second MSU/DAPHNE system with the procurement of a DEC 3000 Alpha host computer, and was used successfully for data-taking in an experiment at ATLAS. Additional hardware for a third system was bought and will be installed. With the availability of 2 MSU/DAPHNE systems in addition to the existing APEX setup, it is planned that the existing DAPHNE front-end will be decommissioned

  7. A high dynamic range data acquisition system for a solid-state electron electric dipole moment experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin; Kunkler, Brandon; Liu, Chen-Yu; Visser, Gerard [CEEM, Physics Department, Indiana University, Bloomington, Indiana 47408 (United States)

    2012-01-15

    We have built a high precision (24-bit) data acquisition (DAQ) system capable of simultaneously sampling eight input channels for the measurement of the electric dipole moment of the electron. The DAQ system consists of two main components: a master board for DAQ control and eight individual analog-to-digital converter (ADC) boards for signal processing. This custom DAQ system provides galvanic isolation of the ADC boards from each other and the master board using fiber optic communication to reduce the possibility of ground loop pickup and attain ultimate low levels of channel cross-talk. In this paper, we describe the implementation of the DAQ system and scrutinize its performance.

  8. Overview of the data acquisition electronics system design for the SLAC Linear Collider Detector (SLD)

    International Nuclear Information System (INIS)

    Larsen, R.S.

    1985-09-01

    The SLD Detector will contain five major electronics subsystems: Vertex, Drift, Liquid Argon Calorimeter, Cerenkov Ring Imaging, and Warm Iron Calorimeter. To implement the approximately 170,000 channels of electronics, extensive miniaturization and heavy use of multiplexing techniques are required. Design criteria for each subsystem, overall system architecture, and the R and D program are described

  9. Instrumentation system for pulsed neutron generator. Pt. 1. Electronic control and data acquisition

    International Nuclear Information System (INIS)

    Burda, J.; Igielski, A.; Janik, W.; Kosik, M.; Kurowski, A.; Zaleski, T.

    1997-01-01

    The paper presents an electronic instrumentation system which is successfully applied for pulsed neutron generator and measurements. In the paper there are described in details all modernized parts of the system as well as new designed and applied ones. The set of diagrams is enclosed. An important part of the system has been designed and built in the Neutron Transport Physics Laboratory. (author)

  10. Data acquisition system for the Hamilton Standard W2 Electron Beam Welder

    International Nuclear Information System (INIS)

    Hopwood, J.

    1979-06-01

    A data acquisition system has been designed which will perform on-line weld-parameter sampling. It is a microprocessor-based program controller and calculator. The parameters sampled are beam current, accelerating voltage, focus-coil current, workpiece rpm, and filament voltage. Sampling in analog form occurs in pre-selected angular-rotation increments from 1 to 9 degrees. There are three data printout options: (A) all data displayed; (B) only out-of-tolerance values displayed; and (C) differences between nominal and sampled values in excess of preselected error bands displayed. A magnetic tape cartridge unit allows long-term data storage and easy retrieval. This report is a manual for system operation. It also describes the design--logic principles, circuitry, and programming--in detail

  11. Data acquisition system for the Hamilton Standard W2 Electron Beam Welder

    Energy Technology Data Exchange (ETDEWEB)

    Hopwood, J.

    1979-06-01

    A data acquisition system has been designed which will perform on-line weld-parameter sampling. It is a microprocessor-based program controller and calculator. The parameters sampled are beam current, accelerating voltage, focus-coil current, workpiece rpm, and filament voltage. Sampling in analog form occurs in pre-selected angular-rotation increments from 1 to 9 degrees. There are three data printout options: (A) all data displayed; (B) only out-of-tolerance values displayed; and (C) differences between nominal and sampled values in excess of preselected error bands displayed. A magnetic tape cartridge unit allows long-term data storage and easy retrieval. This report is a manual for system operation. It also describes the design--logic principles, circuitry, and programming--in detail.

  12. High-speed multi-frame dynamic transmission electron microscope image acquisition system with arbitrary timing

    Science.gov (United States)

    Reed, Bryan W.; DeHope, William J.; Huete, Glenn; LaGrange, Thomas B.; Shuttlesworth, Richard M.

    2016-02-23

    An electron microscope is disclosed which has a laser-driven photocathode and an arbitrary waveform generator (AWG) laser system ("laser"). The laser produces a train of temporally-shaped laser pulses each being of a programmable pulse duration, and directs the laser pulses to the laser-driven photocathode to produce a train of electron pulses. An image sensor is used along with a deflector subsystem. The deflector subsystem is arranged downstream of the target but upstream of the image sensor, and has a plurality of plates. A control system having a digital sequencer controls the laser and a plurality of switching components, synchronized with the laser, to independently control excitation of each one of the deflector plates. This allows each electron pulse to be directed to a different portion of the image sensor, as well as to enable programmable pulse durations and programmable inter-pulse spacings.

  13. High-speed multiframe dynamic transmission electron microscope image acquisition system with arbitrary timing

    Science.gov (United States)

    Reed, Bryan W.; DeHope, William J.; Huete, Glenn; LaGrange, Thomas B.; Shuttlesworth, Richard M.

    2015-10-20

    An electron microscope is disclosed which has a laser-driven photocathode and an arbitrary waveform generator (AWG) laser system ("laser"). The laser produces a train of temporally-shaped laser pulses of a predefined pulse duration and waveform, and directs the laser pulses to the laser-driven photocathode to produce a train of electron pulses. An image sensor is used along with a deflector subsystem. The deflector subsystem is arranged downstream of the target but upstream of the image sensor, and has two pairs of plates arranged perpendicular to one another. A control system controls the laser and a plurality of switching components synchronized with the laser, to independently control excitation of each one of the deflector plates. This allows each electron pulse to be directed to a different portion of the image sensor, as well as to be provided with an independently set duration and independently set inter-pulse spacings.

  14. New KENS data acquisition system

    International Nuclear Information System (INIS)

    Arai, M.; Furusaka, M.; Satoh, S.

    1989-01-01

    In this report, the authors discuss a data acquisition system, KENSnet, which is newly introduced to the KENS facility. The criteria for the data acquisition system was about 1 MIPS for CPU speed and 150 Mbytes for storage capacity for a computer per spectrometer. VAX computers were chosen with their propreitary operating system, VMS. The Vax computers are connected by a DECnet network mediated by Ethernet. Front-end computers, Apple Macintosh Plus and Macintosh II, were chosen for their user-friendly manipulation and intelligence. New CAMAC-based data acquisition electronics were developed. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS and have been installed. 2 refs., 3 figs., 1 tab

  15. Data Acquisition System

    International Nuclear Information System (INIS)

    Cirstea, C.D.; Buda, S.I.; Constantin, F.

    2005-01-01

    This paper deals with a multi parametric acquisition system developed for a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  16. Data acquisition system

    International Nuclear Information System (INIS)

    Cirstea, D.C.; Buda, S.I.; Constantin, F.

    2005-01-01

    The topic of this paper deals with a multi parametric acquisition system developed around a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming, the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  17. Two-Year Operational Evaluation Of A Consumer Electronics-Based Data Acquisition System For Equipment Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Van Hoy, Blake W. [ORNL; Phillips, Larry D. [ORNL; Wetherington Jr, G Randall [ORNL; Damiano, Brian [ORNL; Green, Craig [ORNL

    2017-04-01

    Oak Ridge National Laboratory (ORNL) has performed a two-year evaluation of the performance of an in-house developed consumer electronics-based data acquisition system (DAS). The main advantage of this approach compared to conventional instrumentation grade systems is cost; instrument grade data acquisition systems average costs range from $800 to $2,000 per channel compared to a range of $200 - $400 per channel for a consumer electronics-based system. The DAS is operated as a full-time in-situ vibration monitor. The resulting data stream is streamed over the ORNL network, at an aggregate rate of approximately 2 megabytes/s, to a Linux server. The server includes the capability to implement event-triggered data stores, as well as real-time files for the implementation of continuous display monitoring of the spectra. Detailed spectral analysis is performed post event. The DAS is installed on a large industrial chiller and cooling water pump associated with ORNL’s Titan supercomputer. These mechanical systems include rotating components that operate at fundamental frequencies within the range of 30 Hz to over 3 KHz. Evaluation of the DAS data over a two-year operating period leads to the conclusion that for many industrial processes this system could form the basis for a cost effective means of obtaining operating health data in real time from rotating machinery. The deployment has also shown that the DAS technology is reliable. Furthermore, because the cost of the DAS is low, the other significant advantage of this approach is that the DAS can be deployed in a dedicated manner and operated on a full-time basis.

  18. The CMD-3 Data Acquisition System

    CERN Document Server

    Kozyrev, A N; Epifanov, D A; Epshteyn, L B; Logashenko, I B; Mikhailov, K Yu; Popov, A S; Ruban, A A; Selivanov, A N; Talyshev, A A; Titov, V M; Yudin, Y V

    2017-01-01

    The specialized data acquisition system designed for CMD-3 detector which is installed at the electron-positron collider VEPP-2000 to the Budker Institute of Nuclear Physics, Novosibirsk, Russia. The structure of electronic hardware and firmware is described.

  19. Seismic data acquisition systems

    International Nuclear Information System (INIS)

    Kolvankar, V.G.; Nadre, V.N.; Rao, D.S.

    1989-01-01

    Details of seismic data acquisition systems developed at the Bhabha Atomic Research Centre, Bombay are reported. The seismic signals acquired belong to different signal bandwidths in the band from 0.02 Hz to 250 Hz. All these acquisition systems are built around a unique technique of recording multichannel data on to a single track of an audio tape and in digital form. Techniques of how these signals in different bands of frequencies were acquired and recorded are described. Method of detecting seismic signals and its performance is also discussed. Seismic signals acquired in different set-ups are illustrated. Time indexing systems for different set-ups and multichannel waveform display systems which form essential part of the data acquisition systems are also discussed. (author). 13 refs., 6 figs., 1 tab

  20. MAST data acquisition system

    International Nuclear Information System (INIS)

    Shibaev, S.; Counsell, G.; Cunningham, G.; Manhood, S.J.; Thomas-Davies, N.; Waterhouse, J.

    2006-01-01

    The data acquisition system of the Mega-Amp Spherical Tokamak (MAST) presently collects up to 400 MB of data in about 3000 data items per shot, and subsequent fast growth is expected. Since the start of MAST operations (in 1999) the system has changed dramatically. Though we continue to use legacy CAMAC hardware, newer VME, PCI, and PXI based sub-systems collect most of the data now. All legacy software has been redesigned and new software has been developed. Last year a major system improvement was made-replacement of the message distribution system. The new message system provides easy connection of any sub-system independently of its platform and serves as a framework for many new applications. A new data acquisition controller provides full control of common sub-systems, central error logging, and data acquisition alarms for the MAST plant. A number of new sub-systems using Linux and Windows OSs on VME, PCI, and PXI platforms have been developed. A new PXI unit has been designed as a base sub-system accommodating any type of data acquisition and control devices. Several web applications for the real-time MAST monitoring and data presentation have been developed

  1. Multiprocessor data acquisition system

    International Nuclear Information System (INIS)

    Haumann, J.R.; Crawford, R.K.

    1987-01-01

    A multiprocessor data acquisition system has been built to replace the single processor systems at the Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory. The multiprocessor system was needed to accommodate the higher data rates at IPNS brought about by improvements in the source and changes in instrument configurations. This paper describes the hardware configuration of the system and the method of task sharing and compares results to the single processor system

  2. KENS data acquisition system KENSnet

    International Nuclear Information System (INIS)

    Arai, Masatoshi; Furusaka, Michihiro; Satoh, Setsuo; Johnson, M.W.

    1988-01-01

    The installation of a new data acquisition system KENSnet has been completed at the KENS neutron facility. For data collection, 160 Mbytes are necessary for temporary disk storage, and 1 MIPS of CPU is required. For the computing system, models were chosen from the VAX family of computers running their proprietary operating system VMS. The VMS operating system has a very user friendly interface, and is well suited to instrument control applications. New data acquisition electronics were developed. A gate module receives a signal of proton extraction time from the accelerator, and checks the veto signals from the sample environment equipment (vacuum, temperature, chopper phasing, etc.). Then the signal is issued to a delay-time module. A time-control module starts timing from the delayed start signal from the delay-time module, and distributes an encoded time-boundary address to memory modules at the preset times anabling the memory modules to accumulate data histograms. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS, and have been installed in the new data acquisition system. They give the experimenter 'user-friendly' data acquisition and a good environment for data manipulation. The ICP controls the DAE and transfers the histogram data into the computers. (N.K.)

  3. Acquisition system for the CLIC Module

    CERN Document Server

    Vilalte, Sebastien

    2011-01-01

    The status of R&D activities for CLIC module acquisition are discussed [1]. LAPP is involved in the design of the local CLIC module acquisition crate, described in the document Study of the CLIC Module Front-End Acquisition and Evaluation Electronics [2]. This acquisition system is a project based on a local crate, assigned to the CLIC module, including several mother boards. These motherboards are foreseen to hold mezzanines dedicated to the different subsystems. This system has to work in radiation environment. LAPP is involved in the development of Drive Beam stripline position monitors read-out, described in the document Drive Beam Stripline BPM Electronics and Acquisition [3]. LAPP also develops a generic acquisition mezzanine that allows to perform all-around acquisition and components tests for drive beam stripline BPM read-out.

  4. Front-end electronics and data acquisition system for imaging atmospheric Cherenkov telescopes

    International Nuclear Information System (INIS)

    Chen, Y.T.; La Taille, C. de; Suomijärvi, T.; Cao, Z.; Deligny, O.; Dulucq, F.; Ge, M.M.; Lhenry-Yvon, I.; Martin-Chassard, G.; Nguyen Trung, T.; Wanlin, E.; Xiao, G.; Yin, L.Q.; Yun Ky, B.; Zhang, L.; Zhang, H.Y.; Zhang, S.S.; Zhu, Z.

    2015-01-01

    In this paper, a front-end electronics based on an application-specific integrated circuit (ASIC) is presented for the future imaging atmospheric Cherenkov telescopes (IACTs). To achieve this purpose, a 16-channel ASIC chip, PARISROC 2 (Photomultiplier ARray Integrated in SiGe ReadOut Chip) is used in the analog signal processing and digitization. The digitized results are sent to the server by a user-defined User Datagram Protocol/Internet Protocol (UDP/IP) hardcore engine through Ethernet that is managed by a FPGA. A prototype electronics fulfilling the requirements of the Wide Field of View Cherenkov Telescope Array (WFCTA) of the Large High Altitude Air Shower Observatory (LHAASO) project has been designed, fabricated and tested to prove the concept of the design. A detailed description of the development with the results of the test measurements are presented. By using a new input structure and a new configuration of the ASIC, the dynamic range of the circuit is extended. A highly precise-time calibrating algorithm is also proposed, verified and optimized for the mass production. The test results suggest that the proposed electronics design fulfills the general specification of the future IACTs

  5. Front-end electronics and data acquisition system for imaging atmospheric Cherenkov telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.T., E-mail: chenytao@ynu.edu.cn [Institut de Physique Nucléaire, IN2P3-CNRS, Université Paris-Sud, 91406 Orsay Cedex (France); Yunnan University, 650091 Kunming (China); La Taille, C. de [OMEGA (UMS 3605) - IN2P3/CNRS, Ecole Polytechnique, 91128 Palaiseau Cedex (France); Suomijärvi, T. [Institut de Physique Nucléaire, IN2P3-CNRS, Université Paris-Sud, 91406 Orsay Cedex (France); Cao, Z. [Institute of High Energy Physics, 100049 Beijing (China); Deligny, O. [Institut de Physique Nucléaire, IN2P3-CNRS, Université Paris-Sud, 91406 Orsay Cedex (France); Dulucq, F. [OMEGA (UMS 3605) - IN2P3/CNRS, Ecole Polytechnique, 91128 Palaiseau Cedex (France); Ge, M.M. [Yunnan University, 650091 Kunming (China); Lhenry-Yvon, I. [Institut de Physique Nucléaire, IN2P3-CNRS, Université Paris-Sud, 91406 Orsay Cedex (France); Martin-Chassard, G. [OMEGA (UMS 3605) - IN2P3/CNRS, Ecole Polytechnique, 91128 Palaiseau Cedex (France); Nguyen Trung, T.; Wanlin, E. [Institut de Physique Nucléaire, IN2P3-CNRS, Université Paris-Sud, 91406 Orsay Cedex (France); Xiao, G.; Yin, L.Q. [Institute of High Energy Physics, 100049 Beijing (China); Yun Ky, B. [Institut de Physique Nucléaire, IN2P3-CNRS, Université Paris-Sud, 91406 Orsay Cedex (France); Zhang, L. [Yunnan University, 650091 Kunming (China); Zhang, H.Y. [Tsinghua University, 100084 Beijing (China); Zhang, S.S.; Zhu, Z. [Institute of High Energy Physics, 100049 Beijing (China)

    2015-09-21

    In this paper, a front-end electronics based on an application-specific integrated circuit (ASIC) is presented for the future imaging atmospheric Cherenkov telescopes (IACTs). To achieve this purpose, a 16-channel ASIC chip, PARISROC 2 (Photomultiplier ARray Integrated in SiGe ReadOut Chip) is used in the analog signal processing and digitization. The digitized results are sent to the server by a user-defined User Datagram Protocol/Internet Protocol (UDP/IP) hardcore engine through Ethernet that is managed by a FPGA. A prototype electronics fulfilling the requirements of the Wide Field of View Cherenkov Telescope Array (WFCTA) of the Large High Altitude Air Shower Observatory (LHAASO) project has been designed, fabricated and tested to prove the concept of the design. A detailed description of the development with the results of the test measurements are presented. By using a new input structure and a new configuration of the ASIC, the dynamic range of the circuit is extended. A highly precise-time calibrating algorithm is also proposed, verified and optimized for the mass production. The test results suggest that the proposed electronics design fulfills the general specification of the future IACTs.

  6. An Examination of Electronic Links between the Book Trade and Library Acquisitions Systems.

    Science.gov (United States)

    Bonk, Sharon C.

    Based on interviews and correspondence conducted during 1981, this report describes British library and book trade plans for expansion of their internal order processing systems to include the eventual exchange of data through the use of telecommunications. Comparisons are made between the situation in England and the United States. The report…

  7. Data Acquisition System

    International Nuclear Information System (INIS)

    Watwood, D.; Beatty, J.

    1991-01-01

    The Data Acquisition System (DAS) is comprised of a Hewlett-Packard (HP) model 9816, Series 200 Computer System with the appropriate software to acquire, control, and archive data from a Data Acquisition/Control Unit, models HP3497A and HP3498A. The primary storage medium is an HP9153 16-megabyte hard disc. The data is backed-up on three floppy discs. One floppy disc drive is contained in the HP9153 chassis; the other two comprise an HP9122 dual disc drive. An HP82906A line printer supplies hard copy backup. A block diagram of the hardware setup is shown. The HP3497A/3498A Data Acquisition/Control Units read each input channel and transmit the raw voltage reading to the HP9816 CPU via the HPIB bus. The HP9816 converts this voltage to the appropriate engineering units using the calibration curves for the sensor being read. The HP9816 archives both the raw and processed data along with the time and the readings were taken to hard and floppy discs. The processed values and reading time are printed on the line printer. This system is designed to accommodate several types of sensors; each type is discussed in the following sections

  8. MDSplus data acquisition system

    International Nuclear Information System (INIS)

    Stillerman, J.A.; Fredian, T.W.; Klare, K.; Manduchi, G.

    1997-01-01

    MDSplus, a tree based, distributed data acquisition system, was developed in collaboration with the ZTH Group at Los Alamos National Lab and the RFX Group at CNR in Padua, Italy. It is currently in use at MIT, RFX in Padua, TCV at EPFL in Lausanne, and KBSI in South Korea. MDSplus is made up of a set of X/motif based tools for data acquisition and display, as well as diagnostic configuration and management. It is based on a hierarchical experiment description which completely describes the data acquisition and analysis tasks and contains the results from these operations. These tools were designed to operate in a distributed, client/server environment with multiple concurrent readers and writers to the data store. While usually used over a Local Area Network, these tools can be used over the Internet to provide access for remote diagnosticians and even machine operators. An interface to a relational database is provided for storage and management of processed data. IDL is used as the primary data analysis and visualization tool. IDL is a registered trademark of Research Systems Inc. copyright 1996 American Institute of Physics

  9. Study of Acquisition Electronics with a High Dynamic Range for a Beam Loss Measurement System

    CERN Document Server

    Venturini, G; Dehning, B; Effinger, E

    2010-01-01

    The particles accelerated in CERN accelerator chain reach high energies, topped by the particle energy at collision in the LHC, 7 GeV. During the operation, an amount of particles is inevitably lost from the beam. Depending on the extent of the losses, physical damage to machine components may be caused and the shower of secondary emission particles deposits energy in the surrounding equipment constituting the accelerator. The hadronic cascade also activates their materials, representing a hazard to the workers at CERN. In the LHC, the superconducting magnets that constitute the synchrotron lattice are kept at an operating temperature of 1:9K through a cryogenic facility employing superliquid helium, the increase in their temperature potentially initiates a quench. In the SPS, the damage due to a lost beam is also visible. The Beam Loss Monitoring (BLM) system has been developed to reliably protect the machines composing CERN’s accelerator chain and additionally provide information about the beam status: th...

  10. TCABR data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Fagundes, A.N. E-mail: fagundes@if.usp.br; Sa, W.P.; Coelho, P.M.S.A

    2000-08-01

    A brief description of the design of the data acquisition system for the TCABR tokamak is presented. The system comprises the VME standard instrumentation incorporating CAMAC instrumentation through the use of a GPIB interface. All the necessary data for programming different parts of the equipment, as well as the repertoire of actions for the machine control, are stored in a DBMS, with friendly interfaces. Public access software is used, where feasible, in the development of codes. The TCABR distinguished feature is the virtual lack of frontiers in upgrading, either in hardware or software.

  11. Development of data acquisition system for CSNS 3He detector

    International Nuclear Information System (INIS)

    Zhao Dongxu; Zhang Hongyu

    2012-01-01

    This paper introduces the research and development of data acquisition system of CSNS 3 He detector prototype. This system provides high performance data acquisition capability of CSNS 3 He detector, as well as several performance tests of electronics prototype. This data acquisition system establishes foundation for the later data acquisition development. (authors)

  12. DEAP-3600 Data Acquisition System

    Science.gov (United States)

    Lindner, Thomas

    2015-12-01

    DEAP-3600 is a dark matter experiment using liquid argon to detect Weakly Interacting Massive Particles (WIMPs). The DEAP-3600 Data Acquisition (DAQ) has been built using a combination of commercial and custom electronics, organized using the MIDAS framework. The DAQ system needs to suppress a high rate of background events from 39Ar beta decays. This suppression is implemented using a combination of online firmware and software-based event filtering. We will report on progress commissioning the DAQ system, as well as the development of the web-based user interface.

  13. Data acquisition system for the Pelletron electron accelerator; Sistema de adquisicion y monitoreo de datos para el acelerador de electrones Pelletron

    Energy Technology Data Exchange (ETDEWEB)

    Flores E, O

    1997-04-01

    In this work, a system is developed that allows to know and view of immediate manner the conditions occurred during the operation of the Pelletron. This is carried out by means of the design of a data acquisition system which displays in graphic form, in the screen of a computer, the operation conditions like pressure of the tank, current of the electron beam, voltage in the inductors of the elctrostatic generator, level of produced radiation, etc., all of this parameters determine the behavior of the accelerator. The hardware of the system includes the design and construction of conditioning and transmission circuits used to send the information to an interface board that allows th communication between the analog world and the computer. In this case, the utilized board is the AT-MIO-16L-25, that is a high-performance multifunction analog, digital and timing input/output (I/O) board for the IBM PC/AT and compatibles. The software implicates the design of the necessary programs to manipulate the interface board, for the processing and presentation of information in the screen of the computer and also for the storage of the acquired data in a permanent medium. In this case, a relatively new tool, known like Virtual instrumentation is utilized. Concretely, the LabVIEW programming software package is used (Laboratory Virtual Instrument Engineering Workbench), which is designed for applications in instrumentation and control. This programming package gives the necessary elements for the analysis and processing of the acquired data. The system is developed in base to the requirements done for the users and designers of the Pelletron. (Author).

  14. IPNS data acquisition system

    International Nuclear Information System (INIS)

    Worlton, T.G.; Crawford, R.K.; Haumann, J.R.; Daly, R.

    1983-01-01

    The IPNS Data Acquisition System (DAS) was designed to be reliable, flexible, and easy to use. It provides unique methods of acquiring Time-of-Flight neutron scattering data and allows collection, storage, display, and analysis of very large data arrays with a minimum of user input. Data can be collected from normal detectors, linear position-sensitive detectors, and/or area detectors. The data can be corrected for time-delays and can be time-focussed before being binned. Corrections to be made to the data and selection of inputs to be summed are entirely software controlled, as are the time ranges and resolutions for each detector element. Each system can be configured to collect data into millions of channels. Maximum continuous data rates are greater than 2000 counts/sec with full corrections, or 16,000 counts/sec for the simpler binning scheme used with area detectors. Live displays of the data may be made as a function of time, wavevector, wavelength, lattice spacing, or energy. In most cases the complete data analysis can be done on the DAS host computer. The IPNS DAS became operational for four neutron scattering instruments in 1981 and has since been expanded to seven instruments

  15. Electronics and electronic systems

    CERN Document Server

    Olsen, George H

    1987-01-01

    Electronics and Electronic Systems explores the significant developments in the field of electronics and electronic devices. This book is organized into three parts encompassing 11 chapters that discuss the fundamental circuit theory and the principles of analog and digital electronics. This book deals first with the passive components of electronic systems, such as resistors, capacitors, and inductors. These topics are followed by a discussion on the analysis of electronic circuits, which involves three ways, namely, the actual circuit, graphical techniques, and rule of thumb. The remaining p

  16. The data acquisition system for SLD

    International Nuclear Information System (INIS)

    Sherden, D.J.

    1986-10-01

    This paper describes the data acquisition system planned for the SLD detector, which is being constructed for use with the SLAC Linear Collider (SLC). Analog electronics, heavily incorporating hybrid and custom VLSI circuitry, is mounted on the detector itself. Extensive use is made of multiplexing through optical fibers to a FASTBUS readout system. The low repetition rate of the SLC allows a relatively simple software-based trigger. Hardware and software processors within the acquisition modules are used to reduce the large volume of data per event and to calibrate the electronics. A farm of microprocessors is used for full reconstruction of a sample of events prior to transmission to the host

  17. Data acquisition and online control system for new gas-electron multiplier detectors in the endcap muon system of the CMS experiment

    CERN Document Server

    Ruiz Alvarez, Jose David

    2016-01-01

    A new data acquisition and on-line control system is being developed for gas-electron multiplier (GEM) detectors which will be installed in the forward region (1.6 \\( < \\eta < \\) 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, planned for the period 2018-2019. A prototype system employs the TOTEM VFAT2 ASIC that will eventually be replaced with the VFAT3 ASIC, under development. The front-end ASIC communicates over printed circuit lines with an intermediate on-detector board called the opto-hybrid. Data, trigger, and control information is transmitted via optical fiber between the opto-hybrid and an off-detector readout system using micro-TCA technology. On-line software, implemented in the CMS XDAQ framework, includes applications for latency and HV scans, and system management. We report on the operational status of the prototype system that has been tested using cosmic ray muons and extracted high-energy particle beams. This work is preparatory for the operation of a prot...

  18. Platform attitude data acquisition system

    Digital Repository Service at National Institute of Oceanography (India)

    Afzulpurkar, S.

    A system for automatic acquisition of underwater platform attitude data has been designed, developed and tested in the laboratory. This is a micro controller based system interfacing dual axis inclinometer, high-resolution digital compass...

  19. The electronics, trigger and data acquisition system for the liquid argon time projection chamber of the DarkSide-50 search for dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Caravati, M.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Chepurnov, A.; Cicaló, C.; Cocco, A. G.; Covone, G.; Crippa, L.; D' Angelo, D.; D' Incecco, M.; Davini, S.; de Candia, A.; Cecco, S. De; Deo, M. De; Filippis, G. De; Rosa, G. De; Vincenzi, M. De; Derbin, A.; Devoto, A.; Eusanio, F. Di; Dionisi, C.; Pietro, G. Di; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K. R.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, A.; Ianni, A.; James, I.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Loer, B.; Lombardi, P.; Longo, G.; Luitz, S.; Ma, Y.; Machado, A.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Agasson, A. Navrer; Nelson, A.; Odrowski, S.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.

    2017-12-01

    The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.

  20. The electronics readout and data acquisition system of the KM3NeT neutrino telescope node

    Energy Technology Data Exchange (ETDEWEB)

    Real, Diego [IFIC, Instituto de Física Corpuscular, CSIC-Universidad de Valencia, C/Catedrático José Beltrán, 2, 46980 Paterna (Spain); Collaboration: KM3NeT Collaboration

    2014-11-18

    The KM3NeT neutrino telescope will be composed by tens of thousands of glass spheres, called Digital Optical Module (DOM), each of them containing 31 PMTs of small photocathode area (3'). The readout and data acquisition system of KM3NeT have to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers and at the same time to provide time synchronization between each DOM at the level of 1 ns. It is described in the present article the Central Logic Board, that integrates the Time to Digital Converters and the White Rabbit protocol used for the DOM synchronization in a transparent way, the Power Board used in the DOM, the PMT base to readout the photomultipliers and the respective collecting boards, the so called Octopus Board.

  1. The electronics readout and data acquisition system of the KM3NeT neutrino telescope node

    International Nuclear Information System (INIS)

    Real, Diego

    2014-01-01

    The KM3NeT neutrino telescope will be composed by tens of thousands of glass spheres, called Digital Optical Module (DOM), each of them containing 31 PMTs of small photocathode area (3'). The readout and data acquisition system of KM3NeT have to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers and at the same time to provide time synchronization between each DOM at the level of 1 ns. It is described in the present article the Central Logic Board, that integrates the Time to Digital Converters and the White Rabbit protocol used for the DOM synchronization in a transparent way, the Power Board used in the DOM, the PMT base to readout the photomultipliers and the respective collecting boards, the so called Octopus Board

  2. Portable Data Acquisition System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a portable data acquisition system (PDAT) that can be easily transported and set up at remote locations to display and archive...

  3. Precision cryogenic temperature data acquisition system

    International Nuclear Information System (INIS)

    Farah, Y.; Sondericker, J.H.

    1985-01-01

    A Multiplexed Temperature Data Acquisition System with an overall precision of +-25 ppM has been designed using state-of-the-art electronics to accurately read temperature between 2.4 K and 600 K from pre-calibrated transducers such as germanium, silicon diode, thermistor or platinum temperature sensors

  4. Performance Confirmation Data Acquisition System

    International Nuclear Information System (INIS)

    D.W. Markman

    2000-01-01

    The purpose of this analysis is to identify and analyze concepts for the acquisition of data in support of the Performance Confirmation (PC) program at the potential subsurface nuclear waste repository at Yucca Mountain. The scope and primary objectives of this analysis are to: (1) Review the criteria for design as presented in the Performance Confirmation Data Acquisition/Monitoring System Description Document, by way of the Input Transmittal, Performance Confirmation Input Criteria (CRWMS M and O 1999c). (2) Identify and describe existing and potential new trends in data acquisition system software and hardware that would support the PC plan. The data acquisition software and hardware will support the field instruments and equipment that will be installed for the observation and perimeter drift borehole monitoring, and in-situ monitoring within the emplacement drifts. The exhaust air monitoring requirements will be supported by a data communication network interface with the ventilation monitoring system database. (3) Identify the concepts and features that a data acquisition system should have in order to support the PC process and its activities. (4) Based on PC monitoring needs and available technologies, further develop concepts of a potential data acquisition system network in support of the PC program and the Site Recommendation and License Application

  5. Data acquisition system for LHCb calorimeter

    International Nuclear Information System (INIS)

    Dai Gang; Gong Guanghua; Shao Beibei

    2007-01-01

    LHCb Calorimeter system is mainly used to identify and measure the energy of the photon, electron, hadron produced by the collision of proton. TELL1 is a common data acquisition platform based on FPGA for LHCb experiment. It is used to adopt custom data acquisition and process method for every detector and provide the data standard for the CPU matrix. This paper provides a novel DAQ and data process model in VHDL for Calorimeter. According to this model. We have built an effective Calorimeter DAQ system, which would be used in LHCb Experiment. (authors)

  6. Acquisition parameters optimization of a transmission electron forward scatter diffraction system in a cold-field emission scanning electron microscope for nanomaterials characterization.

    Science.gov (United States)

    Brodusch, Nicolas; Demers, Hendrix; Trudeau, Michel; Gauvin, Raynald

    2013-01-01

    Transmission electron forward scatter diffraction (t-EFSD) is a new technique providing crystallographic information with high resolution on thin specimens by using a conventional electron backscatter diffraction (EBSD) system in a scanning electron microscope. In this study, the impact of tilt angle, working distance, and detector distance on the Kikuchi pattern quality were investigated in a cold-field emission scanning electron microscope (CFE-SEM). We demonstrated that t-EFSD is applicable for tilt angles ranging from -20° to -40°. Working distance (WD) should be optimized for each material by choosing the WD for which the EBSD camera screen illumination is the highest, as the number of detected electrons on the screen is directly dependent on the scattering angle. To take advantage of the best performances of the CFE-SEM, the EBSD camera should be close to the sample and oriented towards the bottom to increase forward scattered electron collection efficiency. However, specimen chamber cluttering and beam/mechanical drift are important limitations in the CFE-SEM used in this work. Finally, the importance of t-EFSD in materials science characterization was illustrated through three examples of phase identification and orientation mapping. © Wiley Periodicals, Inc.

  7. Ion implantation data acquisition system

    International Nuclear Information System (INIS)

    Struttmann, D.A.; Anderl, R.A.

    1989-01-01

    This paper describes a data acquisition system developed for hydrogen ion-driven permeation experiments for materials relevant to fusion technology. The system consists of an IMB PC-AT, CAMAC interface to diagnostic instrumentation and custom-developed software (BASIC) to provide time-history information for signals from several instruments including three quadrupole mass spectrometers. 4 refs., 5 figs

  8. Advanced IPNE data acquisition system

    International Nuclear Information System (INIS)

    Duma, M.; Moisa, D.; Petrovici, M.; Berceanu, I.; Ivascu, M.; Pascovici, G.; Simion, V.; Osvath, E.; Bock, R.; Gobbi, A.; Hildebrand, K.D.; Lynen, U.; Mueller, W.F.J.; Beeskow, M.

    1987-05-01

    A complex and flexible data acquisition system has been developed in order to run relative complex experiments in our acceleration system - ALIGATOR. AIDA programme has been carried out on a small PDP - 11/34 computer and is based on a CAMAC hardware. The main hardware and software features are presented. (authors)

  9. The CBM Experiment at FAIR-New challenges for Front-End Electronics, Data Acquisition and Trigger Systems

    International Nuclear Information System (INIS)

    Mueller, Walter F J

    2006-01-01

    The 'Compressed Baryonic Matter' (CBM) experiment at the new 'Facility for Antiproton and Ion Research' (FAIR) in Darmstadt is designed to study the properties of highly compressed baryonic matter produced in nucleus-nucleus collisions in the 10 to 45 A GeV energy range. One of the key observables is hidden (J/ψ) and open (D 0 , D ± ) charm production. To achieve an adequate sensitivity extremely high interaction rates of up to 10 7 events/second are required, resulting in major technological challenges for the detectors, front-end electronics and data processing. The front-end electronics will be self-triggered, autonomously detect particle hits, and output hit parameter together with a precise absolute time-stamp. Several layers of feature extraction and event selection will reduce the primary data flow of about 1 TByte/sec to a level of 1 GByte/sec. This new architecture avoids many limitations of conventional DAQ/Trigger systems and is for example essential for open charm detection, which requires the reconstruction of displaced vertices, in a high-rate heavy ion environment

  10. Arduino based acquisition system for control applications

    OpenAIRE

    Granado Navarro, Miguel Ángel

    2012-01-01

    The aim of this project is to design an implement a low cost acquisition system intended for control applications using the Arduino prototyping platform. Arduino has become a popular open-source single-board microcontroller among electronic hobbyists, and it is gaining acceptance as a quick prototyping tool for engineering and educational projects also. A computer, using a control application done in LabVIEW or IDE Arduino, must control all the system by cable or wireless. The pro...

  11. The meteorological data acquisition system

    International Nuclear Information System (INIS)

    Bouharrour, S.; Thomas, P.

    1975-07-01

    The 200 m meteorological tower of the Karlsruhe Nuclear Research Center has been equipped with 45 instruments measuring the meteorological parameters near the ground level. Frequent inquiry of the instruments implies data acquisition with on-line data reduction. This task is fulfilled by some peripheral units controlled by a PDP-8/I. This report presents details of the hardware configuration and a short description of the software configuration of the meteorological data acquisition system. The report also serves as an instruction for maintenance and repair work to be carried out at the system. (orig.) [de

  12. The FINUDA data acquisition system

    International Nuclear Information System (INIS)

    Cerello, P.; Marcello, S.; Filippini, V.; Fiore, L.; Gianotti, P.; Raimondo, A.

    1996-07-01

    A parallel scalable Data Acquisition System, based on VME, has been developed to be used in the FINUDA experiment, scheduled to run at the DAPHNE machine at Frascati starting from 1997. The acquisition software runs on embedded RTPC 8067 processors using the LynxOS operating system. The readout of event fragments is coordinated by a suitable trigger Supervisor. data read by different controllers are transported via dedicated bus to a Global Event Builder running on a UNIX machine. Commands from and to VME processors are sent via socket based network protocols. The network hardware is presently ethernet, but it can easily changed to optical fiber

  13. Modelling a data acquisition system

    International Nuclear Information System (INIS)

    Green, P.W.

    1986-01-01

    A data acquisition system to be run on a Data General ECLIPSE computer has been completely designed and developed using a VAX 11/780. This required that many of the features of the RDOS operating system be simulated on the VAX. Advantages and disadvantages of this approach are discussed, with particular regard to transportability of the system among different machines/operating systems, and the effect of the approach on various design decisions

  14. Data acquisition electronics for positron emission mammography (PEM) detectors

    International Nuclear Information System (INIS)

    Martinez, J.D.; Sebastia, A.; Cerda, J.; Esteve, R.; Mora, F.J.; Toledo, J.F.; Benlloch, J.M.; Gimenez, N.; Gimenez, M.; Lerche, Ch. W.; Pavon, N.; Sanchez, F.

    2005-01-01

    Positron emission mammography (PEM) is an innovative technique to increase sensitivity and overcome the main drawbacks of conventional X-ray screening. However, dedicated PET imaging systems demand specific hardware solutions for data acquisition and processing that can take advantage of the reduction in the number of channels. Data acquisition issues can affect PEM scanners performance and they should be exhaustively addressed in order to exploit the increment in the event count rate. This is crucial in order to reduce both the scanning time and the total injected dose. This paper presents the electronics for our PEM camera prototype that enables us to achieve very high-count rates and perform comprehensive online processing. Results about acquisition in our detector for a typical clinical setup are studied using Monte Carlo simulation of hot lesion phantoms

  15. Digital acquisition and processing of electron micrographs using a scanning transmission electron microscope

    International Nuclear Information System (INIS)

    Engel, A.; Christen, F.; Michel, B.

    1981-01-01

    A digital acquisition system that collects multichannel information from a scanning transmission electron microscope (STEM) and its application are described. The hardware comprises (i) single electron counting detectors, (ii) a digital scan generator, (iii) a digital multi-channel on-line processor, (iv) an interface to a minicomputer, and (v) a display system. Experimental results characterizing these components are presented, and their performance is discussed. The software includes assembler coded programs for dynamic file maintenance and fast acquisition of image data, a display driver, and FORTRAN coded application programs. The usefulness of digitized STEM is illustrated by a variety of biological applications. (orig.)

  16. New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, T., E-mail: mizumoto@cr.scphys.kyoto-u.ac.jp [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Matsuoka, Y. [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Mizumura, Y. [Unit of Synergetic Studies for Space, Kyoto University, 606-8502 Kyoto (Japan); Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Tanimori, T. [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Unit of Synergetic Studies for Space, Kyoto University, 606-8502 Kyoto (Japan); Kubo, H.; Takada, A.; Iwaki, S.; Sawano, T.; Nakamura, K.; Komura, S.; Nakamura, S.; Kishimoto, T.; Oda, M.; Miyamoto, S.; Takemura, T.; Parker, J.D.; Tomono, D.; Sonoda, S. [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Miuchi, K. [Department of Physics, Kobe University, 658-8501 Kobe (Japan); Kurosawa, S. [Institute for Materials Research, Tohoku University, 980-8577 Sendai (Japan)

    2015-11-11

    For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10×10×15 cm{sup 3} TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm){sup 3} medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm){sup 3} ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from ~10% to ~100%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.

  17. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University -- Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  18. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  19. Data acquisition systems at Fermilab

    International Nuclear Information System (INIS)

    Votava, M.

    1999-01-01

    Experiments at Fermilab require an ongoing program of development for high speed, distributed data acquisition systems. The physics program at the lab has recently started the operation of a Fixed Target run in which experiments are running the DART[1] data acquisition system. The CDF and D experiments are preparing for the start of the next Collider run in mid 2000. Each will read out on the order of 1 million detector channels. In parallel, future experiments such as BTeV R ampersand D and Minos have already started prototype and test beam work. BTeV in particular has challenging data acquisition system requirements with an input rate of 1500 Gbytes/sec into Level 1 buffers and a logging rate of 200 Mbytes/sec. This paper will present a general overview of these data acquisition systems on three fronts those currently in use, those to be deployed for the Collider Run in 2000, and those proposed for future experiments. It will primarily focus on the CDF and D architectures and tools

  20. Fast Access Data Acquisition System (FADAS)

    International Nuclear Information System (INIS)

    Katsman, Vladimir

    1998-01-01

    Our goal in this program is to develop Fast Access Data Acquisition System (FADAS) by combining the flexibility of Multilink's GaAs and InP electronics and electro-optics with an extremely high data rate for the efficient handling and transfer of collider experimental data. This novel solution is based on Multilink's and Los Alamos National Laboratory's (LANL) unique components and technologies for extremely fast data transfer, storage, and processing

  1. The ALICE data acquisition system

    CERN Document Server

    Carena, F; Chapeland, S; Chibante Barroso, V; Costa, F; Dénes, E; Divià, R; Fuchs, U; Grigore, A; Kiss, T; Simonetti, G; Soós, C; Telesca, A; Vande Vyvre, P; Von Haller, B

    2014-01-01

    In this paper we describe the design, the construction, the commissioning and the operation of the Data Acquisition (DAQ) and Experiment Control Systems (ECS) of the ALICE experiment at the CERN Large Hadron Collider (LHC). The DAQ and the ECS are the systems used respectively for the acquisition of all physics data and for the overall control of the experiment. They are two computing systems made of hundreds of PCs and data storage units interconnected via two networks. The collection of experimental data from the detectors is performed by several hundreds of high-speed optical links. We describe in detail the design considerations for these systems handling the extreme data throughput resulting from central lead ions collisions at LHC energy. The implementation of the resulting requirements into hardware (custom optical links and commercial computing equipment), infrastructure (racks, cooling, power distribution, control room), and software led to many innovative solutions which are described together with ...

  2. The performance of the ZEUS central tracking detector z-by-timing electronics in a transputer based data acquisition system

    International Nuclear Information System (INIS)

    Foster, B.; Heath, G.P.; Llewellyn, T.J.; Gingrich, D.M.; Harnew, N.; Hallam-Baker, P.M.; Khatri, T.; McArthur, I.C.; Morawitz, P.; Nash, J.; Shield, P.D.; Topp-Jorgensen, S.; Wilson, F.F.; Allen, D.B.; Carter, R.C.; Jeffs, M.D.; Morrissey, M.C.; Quinton, S.P.H.; Lane, J.B.; Postranecky, M.

    1993-01-01

    The Central Tracking Detector of the ZEUS experiment employs a time difference technique to measure the z coordinate of each hit. The method provides fast, three-dimensional space point measurements which are used as input to all levels of the ZEUS trigger. Such a tracking trigger is essential in order to discriminate against events with vertices lying outside the nominal electron-proton interaction region. Since the beam crossing interval of the HERA collider is 96 ns, all data must be pipelined through the front-end readout electronics. Subsequent data aquisition employs a novel technique which utilizes a network of approximately 120 INMOS transputers to process the data in parallel. The z-by-timing method and its data aquisition have been employed successfully in recording and reconstructing tracks from electron-proton interactions in ZEUS. (orig.)

  3. Acquisition: Acquisition of the Advanced Deployable System

    National Research Council Canada - National Science Library

    2002-01-01

    ... facility for data processing, evaluation, and reporting. The System will be used to conduct missions, such as threat port surveillance, friendly port protection, area defense, area sanitization, and strategic indications and warnings...

  4. Data acquisition system for SLD

    International Nuclear Information System (INIS)

    Sherden, D.J.

    1985-05-01

    This paper describes the data acquisition system planned for the SLD detector which is being constructed for use with the SLAC Linear Collider (SLC). An exclusively FASTBUS front-end system is used together with a VAX-based host system. While the volume of data transferred does not challenge the band-width capabilities of FASTBUS, extensive use is made of the parallel processing capabilities allowed by FASTBUS to reduce the data to a size which can be handled by the host system. The low repetition rate of the SLC allows a relatively simple software-based trigger. The principal components and overall architecture of the hardware and software are described

  5. Multiparameter data acquisition system for spectroscopy

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Brown, G. V.; Hildebrandt, L.; Wong, K. L.; Ali, R.

    2001-01-01

    A powerful and versatile, simple to use multiparameter data acquisition system has been implemented for use in spectroscopy. In its standard configuration, the system can acquire signal from 16 time-to-digital converter channels, 16 analog-to-digital converter channels, and 12 scaler inputs. The system was put to use on the electron beam ion trap experiment to record the output from four position-sensitive proportional counters in two soft x-ray spectrometers together with the signal from an x-ray pulse height analyzer. Also recorded are the electron beam energy and the pulse height distribution of the proportional counters. All data are recorded as a function of time. Because the relevant parameters are recorded simultaneously, software gates instead of hardware gates are used to select the data of interest. This has led to a substantial cost saving over earlier data acquisition systems. Data are stored in binary or in ascii format for system-independent processing. The operation of the system is demonstrated in a measurement of the M-shell soft x-ray spectrum of gold. We used the system to record the 3--4 and 3--5 transitions of gold (Au 44+ --Au 51+ ) excited with a simulated Maxwellian with electron temperature of 2.5 keV

  6. The BaBar Data Acquisition System

    CERN Document Server

    Scott, I; Grosso, P; Huffer, M E; O'Grady, C; Russell, J J

    1999-01-01

    The BaBar experiment at the Stanford Linear Accelerator Center is designed to perform a search for CP violation by ana-lyzing the decays of a very large sample of B and B(Bar) mesons produced at the high luminosity PEP-II accelerator. The data acquisition system must cope with a sustained high event rate, while supporting real time feature extraction and data compression with minimal dead time. The BaBar data acquisition system is based around a common VME interface to the electronics read-out of the separate detec-tor subsystems. Data from the front end electronics is read into commercial VME processors via a custom "Personality Card" and PCI interface. The commercial CPUs run the Tornado operating system to provide a platform for detector subsystem code to perform the necessary data processing. The data is read out via a non-blocking network switch to a farm of commercial UNIX processors. The current implementation of the BaBar data acquisition sys-tem has been shown to sustain a Level 1 trigger rate of 1.3...

  7. Aerial robotic data acquisition system

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Hayes, D.W.; Pendergast, M.M.

    1995-01-01

    A small unmanned aerial vehicle (UAV) equipped with sensors for physical and chemical measurements of remote environments, is described. A miniature helicopter airframe is used as a platform for sensor testing and development. The sensor output is integrated with the flight control system for real-time, interactive, data acquisition and analysis. Pre programmed flight missions will be flown with several sensors to demonstrate the cost-effective surveillance capabilities of this new technology. (author) 10 refs

  8. The GRIFFIN data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Garnsworthy, A.B., E-mail: garns@triumf.ca [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Pearson, C.J.; Bishop, D.; Shaw, B.; Smith, J.K.; Bowry, M. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Bildstein, V. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada); Hackman, G. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Garrett, P.E. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada); Linn, Y. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Martin, J.-P. [Department of Physics, Université de Montréal, 2900 Boulevard Edouard-Montpetit, Montréal, QC, Canada H3T 1J4 (Canada); Mills, W.J. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Svensson, C.E. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada)

    2017-05-01

    Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty better than 0.05% are described. The system has demonstrated the ability to effectively collect signals from High-purity germanium crystals at counting rates up to 50 kHz while maintaining good energy resolution, detection efficiency and spectral quality.

  9. Crystal ball data acquisition system

    International Nuclear Information System (INIS)

    Chestnut, R.; Kiesling, C.; Bloom, E.; Bulos, F.; Gaiser, J.; Godfrey, G.; Oreglia, M.; Partridge, R.; Peck, C.; Porter, F.; Aschman, D.; Cavali-Sforza, M.; Coyne, D.; Sadrozinski, H.; Kollmann, W.; Richardson, M.

    1979-01-01

    The data acquisition system for the Crystal Ball project at SLAC is described. A PDP-11/t55 using RSX-11M connected to the SLAC Triplex is the basis of the system. A ''physics pipeline'' allows physicists to write their own equipment-monitoring or physics tasks which require event sampling. As well, an interactive analysis package (MULTI) is in the pipeline. Histogram collection and display on the PDP are implemented using the Triplex histogramming package. Various interactive event displays are also implemented

  10. Unmanned Maritime Systems Incremental Acquisition Approach

    Science.gov (United States)

    2016-12-01

    REPORT TYPE AND DATES COVERED MBA professional report 4. TITLE AND SUBTITLE UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH 5. FUNDING...Approved for public release. Distribution is unlimited. UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH Thomas Driscoll, Lieutenant...UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH ABSTRACT The purpose of this MBA report is to explore and understand the issues

  11. Data Acquisition for Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodsinsky, Carlos M. (Inventor)

    2014-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.

  12. Soudan 2 data acquisition and trigger electronics

    International Nuclear Information System (INIS)

    Dawson, J.; Haberichter, W.; Laird, R.

    1985-01-01

    The 1.1 kton Soudan 2 calorimetric drift-chamber detector is read out by 16K anode wires and 32K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 200 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 80C86 microprocessor, which supervises a pipe-lined data compactor, and allows transfer of the compacted data via CAMAC to the host computer. The 80C86's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology

  13. Soudan 2 data acquisition and trigger electronics

    International Nuclear Information System (INIS)

    Dawson, J.; Laird, R.; May, E.; Mondal, N.; Schlereth, J.; Solomey, N.; Thron, J.; Heppelmann, S.

    1985-01-01

    The 1.1 kton Soudan 2 detector is read out by 16K anode wires and 3 2K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 150 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 8086 microprocessors, which supervises a pipe-lined data compactors, and allows transfer of the compacted data via CAMAC to the host computer. The 8086's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology

  14. Soudan 2 data acquisition and trigger electronics

    International Nuclear Information System (INIS)

    Dawson, J.; Heppelmann, S.; Laird, R.; May, E.; Mondal, N.; Schlereth, J.; Solomey, N.; Thron, J.

    1985-01-01

    The 1.1 kton Soudan 2 detector is read out by 16K anode wires and 32K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 150 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 8086 microprocessors, which supervises a pipe-lined data compactors, and allows transfer of the compacted data via CAMAC to the host computer. The 8086's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology

  15. Electron backscatter diffraction: Strategies for reliable data acquisition and processing

    International Nuclear Information System (INIS)

    Randle, Valerie

    2009-01-01

    In electron backscatter diffraction (EBSD) software packages there are many user choices both in data acquisition and in data processing and display. In order to extract maximum scientific value from an inquiry, it is helpful to have some guidelines for best practice in conducting an EBSD investigation. The purpose of this article therefore is to address selected topics of EBSD practice, in a tutorial manner. The topics covered are a brief summary on the principles of EBSD, specimen preparation, calibration of an EBSD system, experiment design, speed of data acquisition, data clean-up, microstructure characterisation (including grain size) and grain boundary characterisation. This list is not meant to cover exhaustively all areas where EBSD is used, but rather to provide a resource consisting of some useful strategies for novice EBSD users.

  16. CAMAC interface for TPC data-acquisition electronics

    International Nuclear Information System (INIS)

    Sidman, S.; Olson, S.; Jared, R.

    1983-06-01

    The Time Projection Chamber (TPC) is a detector used for high-energy physics research at the Stanford PEP Accelerator. TPC requires about 17,000 channels of data acquisition, which samples on command the input to each channel at a 10 MHz rate. This high data rate is made possible by means of Charge Coupled Devices (CCDs), intelligent digitizers, and a sophisticated trigger system. The TPC-CAMAC interface described here was developed to allow experiments of smaller scale than the complete TPC to use the standard data acquisition portion of the TPC electronics, namely the amplifier, CCD and digitizer bins. These three bins, when properly interconnected and controlled by the interface control bin, form a transient digitizer with a depth of 455 samples and a maximum width of 256 channels per bin set

  17. Data acquisition electronics for NESTOR experiment: project and tests

    International Nuclear Information System (INIS)

    Ameli, Fabrizio; Bonori, Maurizio; Bottai, Sergio; Capone, Antonio; Curti, Franco; Desiati, Paolo; De Marchis, Giancarlo; Massa, Fabrizio; Masullo, Rocco; Piccari, Luigi; Vannucci, Italo

    1999-01-01

    The NESTOR detector, at present under construction, is a telescope for high-energy neutrino astronomy. The apparatus, based on Cherenkov light detection, will be deployed in deep sea (about 4000 m) near the S.W. Greek coast. We briefly describe the NESTOR detector, then we describe with more details the electronics for NESTOR data acquisition and transmission. The detector signals are sampled at 200 MHz and all the resulting information are transmitted to the laboratory on 30 km long electro-optical cable. The estimated Mean Time Between Failure of the full electronics system is greater than 20 years. Tests performed on the first prototypes confirm the main characteristics of these electronics: the dynamic range allowed for the signals is bigger than 1000, the pulse shape is reconstructed with an 8 bit ADC accuracy and the resolution in the measurement of the signal 'threshold crossing time' is better than 200 ps

  18. The ALICE data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Carena, F.; Carena, W.; Chapeland, S.; Chibante Barroso, V.; Costa, F. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Dénes, E. [Research Institute for Particle and Nuclear Physics, Wigner Research Center, Budapest (Hungary); Divià, R.; Fuchs, U. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Grigore, A. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Politehnica Univesity of Bucharest, Bucharest (Romania); Kiss, T. [Cerntech Ltd., Budapest (Hungary); Simonetti, G. [Dipartimento Interateneo di Fisica ‘M. Merlin’, Bari (Italy); Soós, C.; Telesca, A.; Vande Vyvre, P. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Haller, B. von, E-mail: bvonhall@cern.ch [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland)

    2014-03-21

    In this paper we describe the design, the construction, the commissioning and the operation of the Data Acquisition (DAQ) and Experiment Control Systems (ECS) of the ALICE experiment at the CERN Large Hadron Collider (LHC). The DAQ and the ECS are the systems used respectively for the acquisition of all physics data and for the overall control of the experiment. They are two computing systems made of hundreds of PCs and data storage units interconnected via two networks. The collection of experimental data from the detectors is performed by several hundreds of high-speed optical links. We describe in detail the design considerations for these systems handling the extreme data throughput resulting from central lead ions collisions at LHC energy. The implementation of the resulting requirements into hardware (custom optical links and commercial computing equipment), infrastructure (racks, cooling, power distribution, control room), and software led to many innovative solutions which are described together with a presentation of all the major components of the systems, as currently realized. We also report on the performance achieved during the first period of data taking (from 2009 to 2013) often exceeding those specified in the DAQ Technical Design Report.

  19. Data acquisition system for MEGHA

    International Nuclear Information System (INIS)

    Chappell, S.P.G.; Hunt, R.A.; Smith, D.; Rae, W.D.M.; Clarke, N.M.; Freer, M.; Fulton, B.R.; Jagpal, S.S.; Singer, S.M.; Watson, D.L.

    2000-01-01

    A multi-channel data acquisition system has been commissioned for the Charissa 'MEGHA' detector array. It is designed to read multiparameter events where there are many potential channels (320) but where only a fraction of these are active in any typical event. Custom-built pre- and main amplifiers process the amplitude (energy) signal from each detector and the system records both amplitude and time of arrival for each signal within an event. The signal amplitude is converted to time using the standard Wilkinson technique and then combined with its time of arrival into a single time trace. These traces are converted by multi-hit TDCs, which only convert the active channels and thus reduce the processing load. Additional custom-built CAMAC modules organise the TDC output into a suitable form for storage and transmission to a network of processor terminals over standard ethernet. This paper presents a description of the data acquisition system from preamplifier through to final storage in a VME-based system and subsequent distribution to a network of Sun terminals over ethernet. The system performance is illustrated with results from heavy-ion elastic scattering recorded with position sensitive strip detectors

  20. Electric vehicle data acquisition system

    DEFF Research Database (Denmark)

    Svendsen, Mathias; Winther-Jensen, Mads; Pedersen, Anders Bro

    2014-01-01

    and industrial applications, e.g. research in electric vehicle driving patterns, vehicle substitutability analysis and fleet management. The platform is based on a embedded computer running Linux, and features a high level of modularity and flexibility. The system operates independently of the make of the car......, by using the On-board Diagnostic port to identify car model and adapt its software accordingly. By utilizing on-board Global Navigation Satellite System, General Packet Radio Service, accelerometer, gyroscope and magnetometer, the system not only provides valuable data for research in the field of electric......A data acquisition system for electric vehicles is presented. The system connects to the On-board Diagnostic port of newer vehicles, and utilizes the in-vehicle sensor network, as well as auxiliary sensors, to gather data. Data is transmitted continuously to a central database for academic...

  1. Modeling of the DZero data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Angstadt, R.; Johnson, M.; Manning, I.L. [Fermi National Accelerator Lab., Batavia, IL (United States); Wightman, J.A. [Texas A and M Univ., College Station, TX (United States). Dept. of Physics]|[Texas Accelerator Center, The Woodlands, TX (United States)

    1991-12-01

    A queuing theory model was used in the initial design of the D0 data acquisition system. It was mainly used for the front end electronic systems. Since then the model has been extended to include the entire data path for the tracking system. The tracking system generates the most data so we expect this system to determine the overall transfer rate. The model was developed using both analytical and simulation methods for solving a series of single server queues. We describe the model and the methods used to develop it. We also present results from the original models, updated calculations representing the system as built and comparisons with measurements made with the hardware in place for the cosmic ray test run. 3 refs.

  2. Modelling of data acquisition systems

    International Nuclear Information System (INIS)

    Buono, S.; Gaponenko, I.; Jones, R.; Mapelli, L.; Mornacchi, G.; Prigent, D.; Sanchez-Corral, E.; Spiwoks, R.; Skiadelli, M.; Ambrosini, G.

    1994-01-01

    The RD13 project was approved in April 1991 for the development of a scalable data taking system suitable to host various LHC studies. One of its goals is to use simulations as a tool for understanding, evaluating, and constructing different configurations of such data acquisition (DAQ) systems. The RD13 project has developed a modelling framework for this purpose. It is based on MODSIM II, an object-oriented, discrete-event simulation language. A library of DAQ components allows to describe a variety of DAQ architectures and different hardware options in a modular and scalable way. A graphical user interface (GUI) is used to do easy configuration, initialization and on-line monitoring of the simulation program. A tracing facility is used to do flexible off-line analysis of a trace file written at run-time

  3. Front-end data processing the SLD data acquisition system

    International Nuclear Information System (INIS)

    Nielsen, B.S.

    1986-07-01

    The data acquisition system for the SLD detector will make extensive use of parallel at the front-end level. Fastbus acquisition modules are being built with powerful processing capabilities for calibration, data reduction and further pre-processing of the large amount of analog data handled by each module. This paper describes the read-out electronics chain and data pre-processing system adapted for most of the detector channels, exemplified by the central drift chamber waveform digitization and processing system

  4. Session summary: Electronics, triggering and data acquisition

    International Nuclear Information System (INIS)

    Rescia, S.

    1991-12-01

    The session focused on the requirements for calorimetry at the SSC/LHC. Results on new readout techniques, calibration, radiation hard electronics and semiconductor devices, analog and digital front and electronics, and trigger strategies are presented

  5. An embedded control and acquisition system for multichannel detectors

    International Nuclear Information System (INIS)

    Gori, L.; Tommasini, R.; Cautero, G.; Giuressi, D.; Barnaba, M.; Accardo, A.; Carrato, S.; Paolucci, G.

    1999-01-01

    We present a pulse counting multichannel data acquisition system, characterized by the high number of high speed acquisition channels, and by the modular, embedded system architecture. The former leads to very fast acquisitions and allows to obtain sequences of snapshots, for the study of time dependent phenomena. The latter, thanks to the integration of a CPU into the system, provides high computational capabilities, so that the interfacing with the user computer is very simple and user friendly. Moreover, the user computer is free from control and acquisition tasks. The system has been developed for one of the beamlines of the third generation synchrotron radiation sources ELETTRA, and because of the modular architecture can be useful in various other kinds of experiments, where parallel acquisition, high data rates, and user friendliness are required. First experimental results on a double pass hemispherical electron analyser provided with a 96 channel detector confirm the validity of the approach. (author)

  6. EBT data acquisition and analysis system

    International Nuclear Information System (INIS)

    Burris, R.D.; Greenwood, D.E.; Stanton, J.S.; Geoffroy, K.A.

    1980-10-01

    This document describes the design and implementation of a data acquisition and analysis system for the EBT fusion experiment. The system includes data acquisition on five computers, automatic transmission of that data to a large, central data base, and a powerful data retrieval system. The system is flexible and easy to use, and it provides a fully documented record of the experiments

  7. Advanced data acquisition system for SEVAN

    Science.gov (United States)

    Chilingaryan, Suren; Chilingarian, Ashot; Danielyan, Varuzhan; Eppler, Wolfgang

    2009-02-01

    Huge magnetic clouds of plasma emitted by the Sun dominate intense geomagnetic storm occurrences and simultaneously they are correlated with variations of spectra of particles and nuclei in the interplanetary space, ranging from subtermal solar wind ions till GeV energy galactic cosmic rays. For a reliable and fast forecast of Space Weather world-wide networks of particle detectors are operated at different latitudes, longitudes, and altitudes. Based on a new type of hybrid particle detector developed in the context of the International Heliophysical Year (IHY 2007) at Aragats Space Environmental Center (ASEC) we start to prepare hardware and software for the first sites of Space Environmental Viewing and Analysis Network (SEVAN). In the paper the architecture of the newly developed data acquisition system for SEVAN is presented. We plan to run the SEVAN network under one-and-the-same data acquisition system, enabling fast integration of data for on-line analysis of Solar Flare Events. An Advanced Data Acquisition System (ADAS) is designed as a distributed network of uniform components connected by Web Services. Its main component is Unified Readout and Control Server (URCS) which controls the underlying electronics by means of detector specific drivers and makes a preliminary analysis of the on-line data. The lower level components of URCS are implemented in C and a fast binary representation is used for the data exchange with electronics. However, after preprocessing, the data are converted to a self-describing hybrid XML/Binary format. To achieve better reliability all URCS are running on embedded computers without disk and fans to avoid the limited lifetime of moving mechanical parts. The data storage is carried out by means of high performance servers working in parallel to provide data security. These servers are periodically inquiring the data from all URCS and storing it in a MySQL database. The implementation of the control interface is based on high level

  8. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  9. Data-Acquisition Systems for Fusion Devices

    NARCIS (Netherlands)

    van Haren, P. C.; Oomens, N. A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology

  10. Data Acquisition System On Beta Installation

    International Nuclear Information System (INIS)

    Abtokhi, Ahmad; Nurhanan; Sudarno; Sumarno, Edy

    2000-01-01

    Data acquisition system is needed on every installation. This is important used to monitoring and processing data to get information desired. This system applied to β installation which is facility to carry out experiments on accident condition like as reflooding phenomena in test section. The 16 exp.th channel data acquisition system is drived by ADC 0804 and programme application DELPHI

  11. The DISTO data acquisition system at SATURNE

    International Nuclear Information System (INIS)

    Balestra, F.; Bedfer, Y.; Bertini, R.

    1998-01-01

    The DISTO collaboration has built a large-acceptance magnetic spectrometer designed to provide broad kinematic coverage of multiparticle final states produced in pp scattering. The spectrometer has been installed in the polarized proton beam of the Saturne accelerator in Saclay to study polarization observables in the rvec pp → pK + rvec Y (Y = Λ, Σ 0 or Y * ) reaction and vector meson production (ψ, ω and ρ) in pp collisions. The data acquisition system is based on a VME 68030 CPU running the OS/9 operating system, housed in a single VME crate together with the CAMAC interface, the triple port ECL memories, and four RISC R3000 CPU. The digitization of signals from the detectors is made by PCOS III and FERA front-end electronics. Data of several events belonging to a single Saturne extraction are stored in VME triple-port ECL memories using a hardwired fast sequencer. The buffer, optionally filtered by the RISC R3000 CPU, is recorded on a DLT cassette by DAQ CPU using the on-board SCSI interface during the acceleration cycle. Two UNIX workstations are connected to the VME CPUs through a fast parallel bus and the Local Area Network. They analyze a subset of events for on-line monitoring. The data acquisition system is able to read and record 3,500 ev/burst in the present configuration with a dead time of 15%

  12. Changing of the ELAN data acquisition to an integrated system with VME frontend acquisition and VAX work station analysis

    International Nuclear Information System (INIS)

    Foerster, W.

    1991-07-01

    A new data acquisition system for the experiment ELAN at the electron stretcher accelerator ELSA had become necessary due to changes in the experimental setup. The data acquisition and analysis which formerly both were performed by a single computer system are now separately done by a VMEbus-Computer and a VAX-Workstation. Based on the software components MECDAS (Mainz Experiment Control and Data Acquisition System) and GOOSY (GSI Online Offline System) a powerfull tool for data acquisition and analysis has been adapted to the requirements of the ELAN experiment. (orig.) [de

  13. The Chateau de Cristal data acquisition system

    International Nuclear Information System (INIS)

    Villard, M.M.

    1987-05-01

    This data acquisition system is built on several dedicated data transfer busses: ADC data readout through the FERA bus, parallel data processing in two VME crates. High data rates and selectivities are performed via this acquisition structure and new developed processing units. The system modularity allows various experiments with additional detectors

  14. Multi spectral scaling data acquisition system

    International Nuclear Information System (INIS)

    Behere, Anita; Patil, R.D.; Ghodgaonkar, M.D.; Gopalakrishnan, K.R.

    1997-01-01

    In nuclear spectroscopy applications, it is often desired to acquire data at high rate with high resolution. With the availability of low cost computers, it is possible to make a powerful data acquisition system with minimum hardware and software development, by designing a PC plug-in acquisition board. But in using the PC processor for data acquisition, the PC can not be used as a multitasking node. Keeping this in view, PC plug-in acquisition boards with on-board processor find tremendous applications. Transputer based data acquisition board has been designed which can be configured as a high count rate pulse height MCA or as a Multi Spectral Scaler. Multi Spectral Scaling (MSS) is a new technique, in which multiple spectra are acquired in small time frames and are then analyzed. This paper describes the details of this multi spectral scaling data acquisition system. 2 figs

  15. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  16. Automation of specimen selection and data acquisition for protein electron crystallography

    NARCIS (Netherlands)

    Oostergetel, G.T.; Keegstra, W.; Brisson, A.D R

    A system is presented for semi-automatic specimen selection and data acquisition for protein electron crystallography, based on a slow-scan CCD camera connected to a transmission electron microscope and control from an external computer. Areas of interest on the specimen are localised at low

  17. A marine meteorological data acquisition system

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Desa, E.; Vithayathil, G.

    A marine meteorological data acquisition system has been developed for long term unattended measurements at remote coastal sites, ocean surface platforms and for use on board research vessels. The system has an open and modular configuration...

  18. Analysis of the SIAM Infrared Acquisition System

    Energy Technology Data Exchange (ETDEWEB)

    Varnado, S.G.

    1974-02-01

    This report describes and presents the results of an analysis of the performance of the infrared acquisition system for a Self-Initiated Antiaircraft Missile (SIAM). A description of the optical system is included, and models of target radiant intensity, atmospheric transmission, and background radiance are given. Acquisition probabilities are expressed in terms of the system signal-to-noise ratio. System performance against aircraft and helicopter targets is analyzed, and background discrimination techniques are discussed. 17 refs., 22 figs., 6 tabs.

  19. Data Acquisition and Real-Time Systems.

    Science.gov (United States)

    Lawrence, D. E., Ed.; Fenwick, P. M., Ed.

    The first group of papers starts with a tutorial paper which surveys the methods used in data acquisition systems. Other papers in this group describe: (1) some problems involved in the computer acquisition of high-speed randomly-occurring data and the protection of this data from accidental corruption, (2) an input/output bus to allow an IBM…

  20. Electron beam fusion data acquisition program DATAIN (EBD)

    International Nuclear Information System (INIS)

    Boyer, W.B.

    1977-02-01

    This report describes the e beam automatic data acquisition program DATAIN. The program was written for a Modular Computer Systems Modcomp II computer interfaced to Tektronix R7912 Transient Digitizers. Operator Communications and data handling steps are described

  1. New developments in electron microscopy for serial image acquisition of neuronal profiles.

    Science.gov (United States)

    Kubota, Yoshiyuki

    2015-02-01

    Recent developments in electron microscopy largely automate the continuous acquisition of serial electron micrographs (EMGs), previously achieved by laborious manual serial ultrathin sectioning using an ultramicrotome and ultrastructural image capture process with transmission electron microscopy. The new systems cut thin sections and capture serial EMGs automatically, allowing for acquisition of large data sets in a reasonably short time. The new methods are focused ion beam/scanning electron microscopy, ultramicrotome/serial block-face scanning electron microscopy, automated tape-collection ultramicrotome/scanning electron microscopy and transmission electron microscope camera array. In this review, their positive and negative aspects are discussed. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Data acquisition for sensor systems

    CERN Document Server

    Taylor, H Rosemary

    1997-01-01

    'Data acquisition' is concerned with taking one or more analogue signals and converting them to digital form with sufficient accu­ racy and speed to be ready for processing by a computer. The increasing use of computers makes this an expanding field, and it is important that the conversion process is done correctly because information lost at this stage can never be regained, no matter how good the computation. The old saying - garbage in, garbage out - is very relevant to data acquisition, and so every part of the book contains a discussion of errors: where do they come from, how large are they, and what can be done to reduce them? The book aims to treat the data acquisition process in depth with less detailed chapters on the fundamental principles of measure­ ment, sensors and signal conditioning. There is also a chapter on software packages, which are becoming increasingly popular. This is such a rapidly changing topic that any review of available pro­ grams is bound to be out of date before the book re...

  3. Acquisition Guide for Interactive Electronic Technical Manuals

    Science.gov (United States)

    2000-04-01

    6.1 ASCII Editors A𔄂 A.6.2 ADEPT*Editor.... Aŝ A.6.3 FrameMaker +SGML (FM+SGML) A൒ A.6.4 IADS A_n A.7 Developing and Editing...Interface A-9 Figure A-6. FrameMaker +SGML Authoring Environment A-l 1 Figure A-7. IADS Reader Aൔ Figure A-8. TechSight Viewer A_13 Figure A-9...errors should be corrected before importing an SGML-tagged file into ADEPT. A.6.3 FrameMaker +SGML (FM+SGML) FM+SGML is an Adobe System product and

  4. An integrated acquisition, display, and analysis system

    International Nuclear Information System (INIS)

    Ahmad, T.; Huckins, R.J.

    1987-01-01

    The design goal of the ND9900/Genuie was to integrate a high performance data acquisition and display subsystem with a state-of-the-art 32-bit supermicrocomputer. This was achieved by integrating a Digital Equipment Corporation MicroVAX II CPU board with acquisition and display controllers via the Q-bus. The result is a tightly coupled processing and analysis system for Pulse Height Analysis and other applications. The system architecture supports distributed processing, so that acquisition and display functions are semi-autonomous, making the VAX concurrently available for applications programs

  5. Advanced Mars Water Acquisition System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Mars Water Acquisition System (AMWAS) recovers and purifies water from Mars soils for oxygen and fuel production, life support, food production, and...

  6. DABASCO Experiment Data Acquisition and Control System

    International Nuclear Information System (INIS)

    Alberdi Primicia, J.; Artigao Arteaga, A.; Barcala Rieveira, J. M.; Oller Gonzalez, J. C.

    2000-01-01

    DABASCO experiment wants to study the thermohydraulic phenomena produced into the containment area for a severe accident in a nuclear power facility. This document describes the characteristics of the data acquisition and control system used in the experiment. The main elements of the system were a data acquisition board, PCI-MIO-16E-4, and an application written with LaB View. (Author) 5 refs

  7. ACP/R3000 processors in data acquisition systems

    International Nuclear Information System (INIS)

    Deppe, J.; Areti, H.; Atac, R.

    1989-02-01

    We describe ACP/R3000 processor based data acquisition systems for high energy physics. This VME bus compatible processor board, with a computational power equivalent to 15 VAX 11/780s or better, contains 8 Mb of memory for event buffering and has a high speed secondary bus that allows data gathering from front end electronics. 2 refs., 3 figs

  8. An improved data acquisition system for isotopic ratio mass spectrometers

    International Nuclear Information System (INIS)

    Saha, T.K.; Reddy, B.; Nazare, C.K.; Handu, V.K.

    1999-01-01

    Isotopic ratio mass spectrometers designed and fabricated to measure the isotopic ratios with a precision of better than 0.05%. In order to achieve this precision, the measurement system consisting of ion signal to voltage converters, analog to digital converters, and data acquisition electronics should be at least one order better than the overall precision of measurement. Using state of the art components and techniques, a data acquisition system, which is an improved version of the earlier system, has been designed and developed for use with multi-collector isotopic ratio mass spectrometers

  9. The WASA Data Acquisition System (WDAQ)

    CERN Document Server

    Gustafsson, L; Sukhanov, A

    1999-01-01

    The WASA Data Acquisition System (WDAQ) is described. It is a modular, and scalable network based system. The chosen structure facilitate that different old and new front-end electronics standards can work together in an efficient way. Fast hardware triggers are created from discriminated signals from specific parts of the WASA detector by extensive use of programmable logic. The trigger logic is configured to do cluster finding in one or two dimensions. The front- end data is linked together in an event-building switch using the Asynchronous Transfer Mode (ATM) protocol and sent to different PC- stations for further filtering, before put onto tape. The data analysis software is using the ROOT (CERN) system which provides a set of object oriented frameworks with all the functionality needed to handle and analyze large amounts of data in a very efficient way. The slow control software is based on the MIDAS (PSI/TRIUMF) system and comprises a fast online database to keep and monitor all WDAQ parameters. The WAS...

  10. Architecture of an acquisition system-multiprocessors

    International Nuclear Information System (INIS)

    Postec, H.

    1987-07-01

    To follow the huge increasing of concerned parameters in nuclear detection systems, acquisition systems become bigger and have to present very good rapidity performance. At Ganil, four detection systems have been set in Nautilus reaction chamber, that lead to experiment configurations with 700 parameters to process. In front of present acquisition system limitation, a device more relevant to lecture of a large number of channels show off necessary. Functionalities already operating in other systems and hardware already used have been chosen; specific technical solutions were aldo developed to use the most recent techniques and to take in account the four detection system structure of the device [fr

  11. CLIC-ACM: Acquisition and Control System

    CERN Document Server

    Bielawski, B; Magnoni, S

    2014-01-01

    CLIC [1] (Compact Linear Collider) is a world-wide collaboration to study the next terascale lepton collider, relying upon a very innovative concept of two-beamacceleration. In this scheme, the power is transported to the main accelerating structures by a primary electron beam. The Two Beam Module (TBM) is a compact integration with a high filling factor of all components: RF, Magnets, Instrumentation, Vacuum, Alignment and Stabilization. This paper describes the very challenging aspects of designing the compact system to serve as a dedicated Acquisition & Control Module (ACM) for all signals of the TBM. Very delicate conditions must be considered, in particular radiation doses that could reach several kGy in the tunnel. In such severe conditions shielding and hardened electronics will have to be taken into consideration. In addition, with more than 300 ADC&DAC channels per ACM and about 21000 ACMs in total, it appears clearly that power consumption will be an important issue. It is also obvious that...

  12. VME data acquisition system. Interactive software for the acquisition, display and storage of one or two dimensional spectra

    International Nuclear Information System (INIS)

    Petremann, E.

    1989-01-01

    The development and construction of a complete data acquisition system for nuclear physics applications, are described. The system is based on the VME bus and the 16/32 bits microprocessor. The data acquisition system enables the obtention of line spectra, involving one or two parameters, and the simultaneous storage of events in a magnetic tape. The analysis and the description of the data acquisition software, the experimental spectra display and saving on magnetic systems are given. Pascal and Assembler are used. The development of cards, for the standard VME and electronic equipment interfaces, is performed [fr

  13. Data acquisition system for nuclear reactor environment

    International Nuclear Information System (INIS)

    Tiwari, Akash; Tiwari, Railesha; Tiwari, S.S.; Panday, Lokesh; Suri, Nitin; Chouksey, Abhsek; Singh, Sarvesh Kumar; Dwivedi, Tarun; Agrawal, Ashish; Pandey, Pranav Kumar; Sharma, Brijnandan; Bhatia, Chirag

    2004-01-01

    We have designed an online real time data acquisition system for nuclear reactor environment monitoring. Data acquisition system has eight channels of analog signals and one channel of pulsed input signal from detectors like GM Tube, or any other similar input. Connectivity between the data acquisition system and environmental parameters monitoring computer is made through a wireless data communication link of 151 MHz/100 mW RF power and 10 km maximum communication range for remote data telemetry. Sensors used are gamma ionizing radiation sensor made from CsI:Tl scintillator, atmospheric pressure sensor with +/-0.1 mbar precision, temperature sensor with +/-l milli degree Celsius precision, relative humidity with +/-0.1RH precision, pulse counts with +/-1 count in 0-10000 Hz count rate measurement precision and +/-1 count is accumulated count measurement precision. The entire data acquisition system and wireless telemetry system is 9 V battery powered and the device is to be fitted on a wireless controlled mobile robot for scanning the nuclear reactor zone from remote. Wireless video camera has been planned for integration into the existing system on a later date for moving the robotics environmental data acquisition system beyond human vision reach. System development cost is Rs.25 Lacs and has been developed for Department of Atomic Energy, Government of India and Indian Defense use. (author)

  14. Five channel data acquisition system for tracer studies

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhananjay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    Radioactive tracers are being used by many modern industries for trouble shooting, process control/quality control and optimization in the process plants. A five channel data acquisition system which has five independent scintillation detector based channels for data acquisition has been developed and made available. This system can be used for tracer studies involving Mean residence time, Resident time distribution and other similar parameters involving tracer movement. System developed can acquire data with dwell times ranging from 10 m sec to 100 sec into each channel and has a capacity to acquire data into 10K channels. Each channel electronics, has a 1x1 NaI Scintillation Detector probe, HV, AMP SCA, micro-controller based data acquisition card with independent dot matrix LCD display for visualization. Extensive use of serial bus (I 2 C, microwire) compatible devices has been incorporated in the design. Data acquisition is initiated simultaneously into all the channels. System design permits delayed/prompt data acquisition selectively. Dual counter switching technique has been employed to achieve faster dwell times for data acquisition. (author)

  15. Mark-II Data Acquisition and Trigger system

    International Nuclear Information System (INIS)

    Breidenbach, M.

    1984-06-01

    The Mark-II Data Acquisition and Trigger system requirements and general solution are described. The solution takes advantage of the synchronous crossing times and low event rates of an electron positron collider to permit a very highly multiplexed analog scheme to be effective. The system depends on a two level trigger to operate with acceptable dead time. The trigger, multiplexing, data reduction, calibration, and CAMAC systems are described

  16. Building blocks for modular data acquisition systems

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, B

    1996-12-31

    The principles of building blocks for modular data acquisition systems by means of the VIC bus are discussed. Real time operating systems based on the VME environment for program development drastically reducing the time needed to develop a working system. 4 figs.

  17. Content Analysis in Systems Engineering Acquisition Activities

    Science.gov (United States)

    2016-04-30

    Acquisition Activities Karen Holness, Assistant Professor, NPS Update on the Department of the Navy Systems Engineering Career Competency Model Clifford...systems engineering toolkit . Having a common analysis tool that is easy to use would support the feedback of observed system performance trends from the

  18. Acquisition system of tandem injector parameters

    International Nuclear Information System (INIS)

    Decourt, M.

    1986-01-01

    The system centralizes all the parameters belonging to the accelerator injector. The acquisition center system reinforces an original device made of cameras and video receivers. Besides giving access to all the parameters of the ion source, the new system allows, in the ''OSCILLO'' mode, to visualize in real time any channel on the oscilloscope [fr

  19. Data acquisition system of the GDL facility

    International Nuclear Information System (INIS)

    Salikova, T.V.

    1992-01-01

    Data acquisition system (DAS) operates in the RSX-IIM environment with the CAMAC system CAMAC driven and CAMAC control processor are used for the CAMAC system operation support. The exchange rate between a problem and the CAMAC module is equal to 100 K worf/c. 14 refs

  20. LAMPF nuclear chemistry data acquisition system

    International Nuclear Information System (INIS)

    Giesler, G.C.

    1983-01-01

    The LAMPF Nuclear Chemistry Data Acquisition System (DAS) is designed to provide both real-time control of data acquisition and facilities for data processing for a large variety of users. It consists of a PDP-11/44 connected to a parallel CAMAC branch highway as well as to a large number of peripherals. The various types of radiation counters and spectrometers and their connections to the system will be described. Also discussed will be the various methods of connection considered and their advantages and disadvantages. The operation of the system from the standpoint of both hardware and software will be described as well as plans for the future

  1. Data Acquisition System for Quartz Crystal Microbalances

    Directory of Open Access Journals (Sweden)

    Kleber Romero Felizardo

    2006-02-01

    Full Text Available This work presents a data acquisition system used in a mass sensor: quartz crystal microbalance. This system reads the frequency of this sensor along the time and sends the collected data to the computer through a serial interface.

  2. Development of the OASIS acquisition system

    International Nuclear Information System (INIS)

    Douet, R.

    1999-01-01

    OASIS is a general purpose data acquisition system built at IPN Orsay, which has been developed around UNIX and VME real time processors. This system can be used to acquire, process, store and display physics data. New OASIS is also used to process event data tapes coming from experiments and has been connected to the analysis software at IPN. (author)

  3. Data acquisition system for TBR-1

    International Nuclear Information System (INIS)

    Fagundes, A.N.

    1989-07-01

    The data acquisition system of Tokamak TBR-1 has as goal to obtain retrieval signal from diagnostic systems. The final process of storage, register and transfer of the signals is described. The hardware used to convert the signals and its storage and the software developed for the operation are discussed [pt

  4. Autonomous System Design for Moessbauer Spectra Acquisition

    International Nuclear Information System (INIS)

    Morales, A. L.; Zuluaga, J.; Cely, A.; Tobon, J.

    2001-01-01

    An autonomous system for Moessbauer spectroscopy based in a microcontroller has been designed. A timer of the microcontroller was used to generate the control signal for the Moessbauer linear motor, and a counter for the spectra acquisition. Additionally, the system has its own memory for data storage and a serial port to transmit the data to a computer for its later processing and display

  5. The data acquisition system of ICT

    International Nuclear Information System (INIS)

    Gao Fuqiang; An Kang; Lu Hua; Cao Peng; Jiang Renqing; Gao Fubing

    2008-01-01

    The purpose of the design is to develop a data acquisition system which can be used to collect and transmit hundreds of channels of weak light signal data at the same time, so as to meet the need of industrial computer tomography. The system is composed of two parts, detection circuit and acquisition circuit. FPGA and 20 bit integral and conversion chips are the primary chips adopted in detection circuit, while the primary chips for acquisition circuit are FPGA and AMCCS5335. The problems, data jam-up and data drop were solved by using multilevel memorizer. A large number of experiments have proved that this system has very high precision and transmission reliability. The design has been applied in several industrial computer tomography machines produced by the industrial computer tomography research center of Chongqing University, and its effectiveness is well apprised. (authors)

  6. The data acquisition system for a SPECT with cylindrical detector

    International Nuclear Information System (INIS)

    Jin Yongjie; Liu Yinong; Li Yuanjing

    1995-01-01

    The data acquisition and position estimation system has been developed for a multi-crystal SPECT with modular cylindrical detector. The electronics screen photon energy determines the detector module stricken by incident photon. The relevant PMT outputs are digitized and passed onto a Pentium PC. Then PMT gain normalization, detector bar identification, energy correction, event coordinates calculation and linearity correction are real-time performed by the PC. The system has been employed in clinical brain imaging

  7. Draft Automatic Data Acquisition System Plan

    International Nuclear Information System (INIS)

    1987-04-01

    This Automatic Data Acquisition System (ADAS) Plan has been prepared in support of the requirement for detailed site characterization of the Deaf Smith County candidate repository site in salt, and describes the data acquisition system which will be used for unattended data collection from the geotechnical instrumentation installed at the site. Section 1.1 discusses the programmatic background to the plan, Section 1.2 presents the scope and purpose of the plan, and the organization of the document is given in Section 1.3. 31 refs., 34 figs., 8 tabs

  8. On Shaft Data Acquisition System (OSDAS)

    Science.gov (United States)

    Pedings, Marc; DeHart, Shawn; Formby, Jason; Naumann, Charles

    2012-01-01

    On Shaft Data Acquisition System (OSDAS) is a rugged, compact, multiple-channel data acquisition computer system that is designed to record data from instrumentation while operating under extreme rotational centrifugal or gravitational acceleration forces. This system, which was developed for the Heritage Fuel Air Turbine Test (HFATT) program, addresses the problem of recording multiple channels of high-sample-rate data on most any rotating test article by mounting the entire acquisition computer onboard with the turbine test article. With the limited availability of slip ring wires for power and communication, OSDAS utilizes its own resources to provide independent power and amplification for each instrument. Since OSDAS utilizes standard PC technology as well as shared code interfaces with the next-generation, real-time health monitoring system (SPARTAA Scalable Parallel Architecture for Real Time Analysis and Acquisition), this system could be expanded beyond its current capabilities, such as providing advanced health monitoring capabilities for the test article. High-conductor-count slip rings are expensive to purchase and maintain, yet only provide a limited number of conductors for routing instrumentation off the article and to a stationary data acquisition system. In addition to being limited to a small number of instruments, slip rings are prone to wear quickly, and introduce noise and other undesirable characteristics to the signal data. This led to the development of a system capable of recording high-density instrumentation, at high sample rates, on the test article itself, all while under extreme rotational stress. OSDAS is a fully functional PC-based system with 48 channels of 24-bit, high-sample-rate input channels, phase synchronized, with an onboard storage capacity of over 1/2-terabyte of solid-state storage. This recording system takes a novel approach to the problem of recording multiple channels of instrumentation, integrated with the test

  9. PC based 8-parameter data acquisition system

    International Nuclear Information System (INIS)

    Gupta, J.D.; Naik, K.V.; Jain, S.K.; Pathak, R.V.; Suman, B.

    1989-01-01

    Multiparameter data acquisition (MPA) systems which analyse nuclear events with respect to more than one property of the event are essential tools for the study of some complex nuclear phenomena requiring analysis of time coincident spectra. For better throughput and accuracy each parameter is digitized by its own ADC. A stand alone low cost IBM PC based 8-parameter data acquisition system developed by the authors makes use of Address Recording technique for acquiring data from eight 12 bit ADC's in the PC Memory. Two memory buffers in the PC memory are used in ping-pong fashion so that data acquisition in one bank and dumping of data onto PC disk from the other bank can proceed simultaneously. Data is acquired in the PC memory through DMA mode for realising high throughput and hardware interrupt is used for switching banks for data acquisition. A comprehensive software package developed in Turbo-Pascal offers a set of menu-driven interactive commands to the user for setting-up system parameters and control of the system. The system is to be used with pelletron accelerator. (author). 5 figs

  10. Complex System Governance for Acquisition

    Science.gov (United States)

    2016-04-30

    are not the privilege, or curse, of any particular field or sector (energy, utilities, healthcare, transportation , commerce, defense, security...2005; Whitney et al., 2015) and Management Cybernetics ( Beer , 1972, 1979, 1985) and the field has been built upon their philosophical, theoretical, and...et al., 2015), while Management Cybernetics has been identified as the science of effective (system) organization ( Beer , 1972). Following from the

  11. Electronic payment systems

    OpenAIRE

    Mláka, Michal

    2010-01-01

    This bachelor thesis analysis issue of electronic payment systems. It discusses their use for payments on the internet and sending funds via e-mail. The first part is devoted to the theoretical definition and legislation of the issuance of electronic money and activities of electronic money institutions. The main part of the work clearly focuses on the use of e-wallets, which is an integral part of electronic payment systems. E-wallet of electronic payment system Moneybookers is considered as...

  12. DAISY - the Oslo Cyclotron data acquisition system

    International Nuclear Information System (INIS)

    Ramsoey, T.

    1991-08-01

    The new CACTUS multidetector system for the Oslo Cyclotron consists of 8 particle telescopes, 28 NAI detectors and 2 Ge detectors. Each detector gives rise to one energy parameter and one time parameter. Thus, a total of 80 parameters are present. The counting rate is 100 kByte/s for the highest beam intensities. A new data acquisition system, DAISY, satisfying these demands has been designed. The present report is intended as a complete technical manual for the new system. 24 refs

  13. Data acquisition system from uncorrelated experimental inputs

    International Nuclear Information System (INIS)

    Bals, I.; Caprini, M.; Goran, B.; Lutescu, S.; Niculescu, D.

    1974-01-01

    The system described in this work was performed as a small acquisition center for neutron physics experiment and was designed as a specialized device. The system was entirely MSI and SSI integrated circuits performed using 33 double sided printed circuit boards. The modular structure with information flow on buses led to wining simplification. The system can be further developed, using appropriate interfaces and programming modules to extend the range of possible experiments

  14. Neutral particle beam distributed data acquisition system

    International Nuclear Information System (INIS)

    Daly, R.T.; Kraimer, M.R.; Novick, A.H.

    1987-01-01

    A distributed data acquisition system has been designed to support experiments at the Argonne Neutral Particle Beam Accelerator. The system uses a host VAXstation II/GPX computer acting as an experimenter's station linked via Ethernet with multiple MicroVAX IIs and rtVAXs dedicated to acquiring data and controlling hardware at remote sites. This paper describes the hardware design of the system, the applications support software on the host and target computers, and the real-time performance

  15. Data acquisition on a VME/68000 system

    International Nuclear Information System (INIS)

    Aoun, Walid

    1990-01-01

    A data acquisition system for correlated or independent events handling has been designed. This system is based on VME boards and 68000 processors. The software include data taking, on line sort and storage on magnetic tape. A driver has been written under the UNIX operating system for a high graphic resolution VME board, this implementation was provided as an off-line facility. (author) [fr

  16. New data acquisition system for AMS

    Energy Technology Data Exchange (ETDEWEB)

    Pfenninger, R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A new data acquisition system based on a VME front-end computer, a Sun workstation and a PC has been installed. It is used for the acquisition of mainly AMS data, their graphical display, and storage of the data in a Oracle database. The measurement of magazines of 25 sample each is fully automated. Several data parameters such as transmission are regularly checked. In case of problems the operator is informed by optical and/or acoustical signals. Screens are updated automatically after every measurement cycle. (author) 1 fig.

  17. Optimization of Hierarchical System for Data Acquisition

    Directory of Open Access Journals (Sweden)

    V. Novotny

    2011-04-01

    Full Text Available Television broadcasting over IP networks (IPTV is one of a number of network applications that are except of media distribution also interested in data acquisition from group of information resources of variable size. IP-TV uses Real-time Transport Protocol (RTP protocol for media streaming and RTP Control Protocol (RTCP protocol for session quality feedback. Other applications, for example sensor networks, have data acquisition as the main task. Current solutions have mostly problem with scalability - how to collect and process information from large amount of end nodes quickly and effectively? The article deals with optimization of hierarchical system of data acquisition. Problem is mathematically described, delay minima are searched and results are proved by simulations.

  18. Embedded Linux platform for data acquisition systems

    International Nuclear Information System (INIS)

    Patel, Jigneshkumar J.; Reddy, Nagaraj; Kumari, Praveena; Rajpal, Rachana; Pujara, Harshad; Jha, R.; Kalappurakkal, Praveen

    2014-01-01

    Highlights: • The design and the development of data acquisition system on FPGA based reconfigurable hardware platform. • Embedded Linux configuration and compilation for FPGA based systems. • Hardware logic IP core and its Linux device driver development for the external peripheral to interface it with the FPGA based system. - Abstract: This scalable hardware–software system is designed and developed to explore the emerging open standards for data acquisition requirement of Tokamak experiments. To address the future need for a scalable data acquisition and control system for fusion experiments, we have explored the capability of software platform using Open Source Embedded Linux Operating System on a programmable hardware platform such as FPGA. The idea was to identify the platform which can be customizable, flexible and scalable to support the data acquisition system requirements. To do this, we have selected FPGA based reconfigurable and scalable hardware platform to design the system with Embedded Linux based operating system for flexibility in software development and Gigabit Ethernet interface for high speed data transactions. The proposed hardware–software platform using FPGA and Embedded Linux OS offers a single chip solution with processor, peripherals such ADC interface controller, Gigabit Ethernet controller, memory controller amongst other peripherals. The Embedded Linux platform for data acquisition is implemented and tested on a Virtex-5 FXT FPGA ML507 which has PowerPC 440 (PPC440) [2] hard block on FPGA. For this work, we have used the Linux Kernel version 2.6.34 with BSP support for the ML507 platform. It is downloaded from the Xilinx [1] GIT server. Cross-compiler tool chain is created using the Buildroot scripts. The Linux Kernel and Root File System are configured and compiled using the cross-tools to support the hardware platform. The Analog to Digital Converter (ADC) IO module is designed and interfaced with the ML507 through Xilinx

  19. Embedded Linux platform for data acquisition systems

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Jigneshkumar J., E-mail: jjp@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Reddy, Nagaraj, E-mail: nagaraj.reddy@coreel.com [Sandeepani School of Embedded System Design, Bangalore, Karnataka (India); Kumari, Praveena, E-mail: praveena@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Rajpal, Rachana, E-mail: rachana@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Pujara, Harshad, E-mail: pujara@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Jha, R., E-mail: rjha@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Kalappurakkal, Praveen, E-mail: praveen.k@coreel.com [Sandeepani School of Embedded System Design, Bangalore, Karnataka (India)

    2014-05-15

    Highlights: • The design and the development of data acquisition system on FPGA based reconfigurable hardware platform. • Embedded Linux configuration and compilation for FPGA based systems. • Hardware logic IP core and its Linux device driver development for the external peripheral to interface it with the FPGA based system. - Abstract: This scalable hardware–software system is designed and developed to explore the emerging open standards for data acquisition requirement of Tokamak experiments. To address the future need for a scalable data acquisition and control system for fusion experiments, we have explored the capability of software platform using Open Source Embedded Linux Operating System on a programmable hardware platform such as FPGA. The idea was to identify the platform which can be customizable, flexible and scalable to support the data acquisition system requirements. To do this, we have selected FPGA based reconfigurable and scalable hardware platform to design the system with Embedded Linux based operating system for flexibility in software development and Gigabit Ethernet interface for high speed data transactions. The proposed hardware–software platform using FPGA and Embedded Linux OS offers a single chip solution with processor, peripherals such ADC interface controller, Gigabit Ethernet controller, memory controller amongst other peripherals. The Embedded Linux platform for data acquisition is implemented and tested on a Virtex-5 FXT FPGA ML507 which has PowerPC 440 (PPC440) [2] hard block on FPGA. For this work, we have used the Linux Kernel version 2.6.34 with BSP support for the ML507 platform. It is downloaded from the Xilinx [1] GIT server. Cross-compiler tool chain is created using the Buildroot scripts. The Linux Kernel and Root File System are configured and compiled using the cross-tools to support the hardware platform. The Analog to Digital Converter (ADC) IO module is designed and interfaced with the ML507 through Xilinx

  20. In-situ straining and time-resolved electron tomography data acquisition in a transmission electron microscope.

    Science.gov (United States)

    Hata, S; Miyazaki, S; Gondo, T; Kawamoto, K; Horii, N; Sato, K; Furukawa, H; Kudo, H; Miyazaki, H; Murayama, M

    2017-04-01

    This paper reports the preliminary results of a new in-situ three-dimensional (3D) imaging system for observing plastic deformation behavior in a transmission electron microscope (TEM) as a directly relevant development of the recently reported straining-and-tomography holder [Sato K et al. (2015) Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography. Microsc. 64: 369-375]. We designed an integrated system using the holder and newly developed straining and image-acquisition software and then developed an experimental procedure for in-situ straining and time-resolved electron tomography (ET) data acquisition. The software for image acquisition and 3D visualization was developed based on the commercially available ET software TEMographyTM. We achieved time-resolved 3D visualization of nanometer-scale plastic deformation behavior in a Pb-Sn alloy sample, thus demonstrating the capability of this system for potential applications in materials science. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Magnetic Field Response Measurement Acquisition System

    Science.gov (United States)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  2. Performance confirmation data acquisition system

    International Nuclear Information System (INIS)

    McAffee, D.A.; Raczka, N.T.

    1997-01-01

    As part of the Viability Assessment (VA) work, this QAP-3-9 document presents and evaluates a comprehensive set of viable concepts for collecting Performance Confirmation (PC) related data. The concepts include: monitoring subsurface repository air temperatures, humidity levels and gaseous emissions via the subsurface ventilation systems, and monitoring the repository geo-technical parameters and rock mass from bore-holes located along the perimeter main drifts and throughout a series of human-rated Observation Drifts to be located in a plane 25 meters above the plane of the emplacement drifts. A key element of this document is the development and analysis of a purposed multi-purpose Remote Inspection Gantry that would provide direct, real-time visual, thermal, and radiological monitoring of conditions inside operational emplacement drifts and close-up observations of in-situ Waste Packages. Preliminary finite-element analyses are presented that indicate the technological feasibility of operating an inspection gantry inside the operational emplacement drifts for short inspection missions lasting 2--3 hours. Overall reliability, availability, and maintainability of the PC data collection concepts are discussed. Preliminary concepts for PC data collection network are also provided

  3. Performance confirmation data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    McAffee, D.A.; Raczka, N.T. [Yucca Mountain Project, Las Vegas, NV (United States)

    1997-12-31

    As part of the Viability Assessment (VA) work, this QAP-3-9 document presents and evaluates a comprehensive set of viable concepts for collecting Performance Confirmation (PC) related data. The concepts include: monitoring subsurface repository air temperatures, humidity levels and gaseous emissions via the subsurface ventilation systems, and monitoring the repository geo-technical parameters and rock mass from bore-holes located along the perimeter main drifts and throughout a series of human-rated Observation Drifts to be located in a plane 25 meters above the plane of the emplacement drifts. A key element of this document is the development and analysis of a purposed multi-purpose Remote Inspection Gantry that would provide direct, real-time visual, thermal, and radiological monitoring of conditions inside operational emplacement drifts and close-up observations of in-situ Waste Packages. Preliminary finite-element analyses are presented that indicate the technological feasibility of operating an inspection gantry inside the operational emplacement drifts for short inspection missions lasting 2--3 hours. Overall reliability, availability, and maintainability of the PC data collection concepts are discussed. Preliminary concepts for PC data collection network are also provided.

  4. Data acquisition systems for fusion devices

    International Nuclear Information System (INIS)

    Van Haren, P.C.; Oomens, N.A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology driven; the emphasis has been on the development of computer hardware and system software. For future DASs, challenging problems are to be solved: The DASs have to be better optimized with respect to the needs of the users. Existing bottlenecks, such as CAMAC-computer coupling or pulse file merging, need to be eliminated. Continuous or long-pulse operation will require the introduction of event abstraction in DAS design. 59 refs., 4 figs., 1 tab

  5. Embedded data acquisition system with MDSPlus

    International Nuclear Information System (INIS)

    Rajpal, Rachana; Patel, Jigneshkumar; Kumari, Praveena; Panchal, Vipul; Chattopadhyay, P.K.; Pujara, Harshad; Saxena, Y.C.

    2012-01-01

    This data acquisition system (DAS) is designed and developed to cater the increasing demand of Plasma Diagnostics for Aditya Tokamak as well as to support the basic physics research going on at Institute for Plasma Research. The main design criteria were to design a system with minimum resources and flexible to cater the needs of slow and fast diagnostic channels and can be easily integrated with the existing data acquisition system of Aditya Tokamak. The DAS is designed on embedded PC/104 platform. This is a multi channel system which supports standard features of commercially available DAS. The control and bus interface logic are implemented using Very High Speed Hardware Description Language (VHDL) on Complex Programmable Logic Device (CPLD). For Aditya Tokamak pulse experiment, the software application is designed such that the data is directly integrated to the MDSplus tree of Aditya DAS. The detailed hardware and software design, development and testing results will be discussed in the paper.

  6. Data acquisition and test system software

    International Nuclear Information System (INIS)

    Bourgeois, N.A. Jr.

    1979-03-01

    Sandia Laboratories has been assigned the task by the Base and Installation Security Systems (BISS) Program Office to develop various aspects of perimeter security systems. One part of this effort involves the development of advanced signal processing techniques to reduce the false and nuisance alarms from sensor systems while improving the probability of intrusion detection. The need existed for both data acquisition hardware and software. Also, the hardware is used to implement and test the signal processing algorithms in real time. The hardware developed for this signal processing task is the Data Acquisition and Test System (DATS). The programs developed for use on DATS are described. The descriptions are taken directly from the documentation included within the source programs themselves

  7. Software for nuclear data acquisition systems

    International Nuclear Information System (INIS)

    Christensen, P.

    1983-01-01

    The situation for experimenters and system designers needing software for instrumentation is described. It is stated that software for a data acquisition system can be divided into programmes described as the foundation software, the applications programme, and the analysis programme. Special attention is given to CAMAC. Two examples from Risoe describing data transportation and archiving are given. Finally the supply of software and the problems of documentation are described. (author)

  8. The ngdp framework for data acquisition systems

    OpenAIRE

    Isupov, A. Yu.

    2010-01-01

    The ngdp framework is intended to provide a base for the data acquisition (DAQ) system software. The ngdp's design key features are: high modularity and scalability; usage of the kernel context (particularly kernel threads) of the operating systems (OS), which allows to avoid preemptive scheduling and unnecessary memory--to--memory copying between contexts; elimination of intermediate data storages on the media slower than the operating memory like hard disks, etc. The ngdp, having the above ...

  9. The UA1 VME data acquisition system

    International Nuclear Information System (INIS)

    Cittolin, S.

    1988-01-01

    The data acquisition system of a large-scale experiment such as UA1, running at the CERN proton-antiproton collider, has to cope with very high data rates and to perform sophisticated triggering and filtering in order to analyze interesting events. These functions are performed by a variety of programmable units organized in a parallel multiprocessor system whose central architecture is based on the industry-standard VME/VMXbus. (orig.)

  10. Data acquisition and processing system for reactor noise analysis

    International Nuclear Information System (INIS)

    Costa Oliveira, J.; Morais Da Veiga, C.; Forjaz Trigueiros, D.; Pombo Duarte, J.

    1975-01-01

    A data acquisition and processing system for reactor noise analysis by time correlation methods is described, consisting in one to four data feeding channels (transducer, associated electronics and V/f converter), a sampling unit, a landline transmission system and a PDP 15 computer. This system is being applied to study the kinetic parameters of the 'Reactor Portugues de Investigacao', a swimming-pool 1MW reactor. The main features that make such a data acquisition and processing system a useful tool to perform noise analysis are: the improved characteristics of analog-to-digital converters employed to quantize the signals; the use of an on-line computer which allows a great accumulation and a rapid treatment of data together with an easy check of the correctness of the experiments; and the adoption of the time cross-correlation technique using two-detectors which by-pass the limitation of low efficiency detectors. (author)

  11. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  12. Microcomputer-controlled ultrasonic data acquisition system

    International Nuclear Information System (INIS)

    Simpson, W.A. Jr.

    1978-11-01

    The large volume of ultrasonic data generated by computer-aided test procedures has necessitated the development of a mobile, high-speed data acquisition and storage system. This approach offers the decided advantage of on-site data collection and remote data processing. It also utilizes standard, commercially available ultrasonic instrumentation. This system is controlled by an Intel 8080A microprocessor. The MCS80-SDK microcomputer board was chosen, and magnetic tape is used as the storage medium. A detailed description is provided of both the hardware and software developed to interface the magnetic tape storage subsystem to Biomation 8100 and Biomation 805 waveform recorders. A boxcar integrator acquisition system is also described for use when signal averaging becomes necessary. Both assembly language and machine language listings are provided for the software

  13. Reducing acquisition risk through integrated systems of systems engineering

    Science.gov (United States)

    Gross, Andrew; Hobson, Brian; Bouwens, Christina

    2016-05-01

    In the fall of 2015, the Joint Staff J7 (JS J7) sponsored the Bold Quest (BQ) 15.2 event and conducted planning and coordination to combine this event into a joint event with the Army Warfighting Assessment (AWA) 16.1 sponsored by the U.S. Army. This multipurpose event combined a Joint/Coalition exercise (JS J7) with components of testing, training, and experimentation required by the Army. In support of Assistant Secretary of the Army for Acquisition, Logistics, and Technology (ASA(ALT)) System of Systems Engineering and Integration (SoSE&I), Always On-On Demand (AO-OD) used a system of systems (SoS) engineering approach to develop a live, virtual, constructive distributed environment (LVC-DE) to support risk mitigation utilizing this complex and challenging exercise environment for a system preparing to enter limited user test (LUT). AO-OD executed a requirements-based SoS engineering process starting with user needs and objectives from Army Integrated Air and Missile Defense (AIAMD), Patriot units, Coalition Intelligence, Surveillance and Reconnaissance (CISR), Focused End State 4 (FES4) Mission Command (MC) Interoperability with Unified Action Partners (UAP), and Mission Partner Environment (MPE) Integration and Training, Tactics and Procedures (TTP) assessment. The SoS engineering process decomposed the common operational, analytical, and technical requirements, while utilizing the Institute of Electrical and Electronics Engineers (IEEE) Distributed Simulation Engineering and Execution Process (DSEEP) to provide structured accountability for the integration and execution of the AO-OD LVC-DE. As a result of this process implementation, AO-OD successfully planned for, prepared, and executed a distributed simulation support environment that responsively satisfied user needs and objectives, demonstrating the viability of an LVC-DE environment to support multiple user objectives and support risk mitigation activities for systems in the acquisition process.

  14. Isothermal thermogravimetric data acquisition analysis system

    Science.gov (United States)

    Cooper, Kenneth, Jr.

    1991-01-01

    The description of an Isothermal Thermogravimetric Analysis (TGA) Data Acquisition System is presented. The system consists of software and hardware to perform a wide variety of TGA experiments. The software is written in ANSI C using Borland's Turbo C++. The hardware consists of a 486/25 MHz machine with a Capital Equipment Corp. IEEE488 interface card. The interface is to a Hewlett Packard 3497A data acquisition system using two analog input cards and a digital actuator card. The system provides for 16 TGA rigs with weight and temperature measurements from each rig. Data collection is conducted in three phases. Acquisition is done at a rapid rate during initial startup, at a slower rate during extended data collection periods, and finally at a fast rate during shutdown. Parameters controlling the rate and duration of each phase are user programmable. Furnace control (raising and lowering) is also programmable. Provision is made for automatic restart in the event of power failure or other abnormal terminations. Initial trial runs were conducted to show system stability.

  15. A data acquisition system based on a personal computer

    International Nuclear Information System (INIS)

    Omata, K.; Fujita, Y.; Yoshikawa, N.; Sekiguchi, M.; Shida, Y.

    1991-07-01

    A versatile and flexible data acquisition system KODAQ (Kakuken Online Data AcQuisition system) has been developed. The system runs with CAMAC and a most popular Japanese personal computer, PC9801 (NEC), similar to the IBM PC/AT. The system is designed to set up easily a data acquisition system for various kinds of nuclear-physics experiments. (author)

  16. MPS [Multiparticle Spectrometer] data acquisition software system

    International Nuclear Information System (INIS)

    Saulys, A.C.; Etkin, A.; Foley, K.J.

    1989-01-01

    A description of the software for a FASTBUS based data acquisition system in use at the Brookhaven National Laboratory Multiparticle Spectrometer is presented. Data reading and formatting is done by the SLAC Scanner Processors (SSP's) resident in the FASTBUS system. A multiprocess software system on VAX computers is used to communicate with the SSP's, record the data, and monitor on-line the progress of high energy and heavy ion experiments. The structure and the performance of this system are discussed. 4 refs., 1 fig

  17. Acquisition system testing with superfluid helium

    International Nuclear Information System (INIS)

    Anderson, J.E.; Fester, D.A.; DiPirro, M.J.

    1988-01-01

    NASA is evaluating both a thermomechanical pump and centrifugal pump for the SHOOT experiment using capillary fluid acquisition systems. Tests were conducted for these systems with superfluid helium under adverse operating conditions. Minus one-g outflow tests were run in conjunction with the thermomechanical pump. Both fine mesh screen and porous sponges were tested. A screen acquisition device was also tested with the low-NPSH centrifugal pump. Results to date show that the screen and sponge are capable of supplying superfluid helium to the thermomechanical pump inlet against a one-g head up to four cm. This is more than sufficient for the SHOOT application. Results with the sponge were reproducible while those with the screen could not always be repeated

  18. Candidate sample acquisition systems for the Rosetta

    International Nuclear Information System (INIS)

    Magnani, P.G.; Gerli, C.; Colombina, G.; Vielmo, P.

    1989-01-01

    The Comet Nucleus Sample Return (CNSR) mission, one of the four cornerstones of the ESA scientific program, is one of the most complex space ventures within the next century, both from technological and deep space exploration point of view. In the Rosetta scenario the sample acquisition phase represents the most critical point for the global mission's success. The proposed paper illustrates the main results obtained in the context of the CNSR-SAS ongoing activity. The main areas covered are related to: (1) sample properties characterization (comet soil model, physical/chemical properties, reference material for testing); (2) concepts identification for coring, shovelling, harpooning and anchoring; (3) preferred concept (trade off among concepts, identification of the preferred configuration); and (4) proposed development activity for gaining the necessary confidence before finalizing the CNSR mission. Particular emphasis will be given to the robotic and flexibility aspects of the identified sample acquisition systems (SAS) configuration, intended as a means for the overall system performance enhancement

  19. ORELA data acquisition system hardware. Volume 1: introduction

    International Nuclear Information System (INIS)

    Reynolds, J.W.

    1977-01-01

    The Oak Ridge Electron Linear Accelerator Facility (ORELA) has been specifically designed as a facility for neutron cross-section measurements by the time-of-flight technique. ORELA was designed so that a number of cross-section experiments can be performed simultaneously. This goal of simultaneous operation of several experiments, a maximum of six to date, has been achieved by using the multiple flight paths radiating from the target room, the multiple flight stations on each flight path, the laboratory facilities surrounding the central data area, and a shared data acquisition computer system. The flight stations contain the fast electronics for initial processing of the nuclear detector signals on a time scale of nanoseconds. The laboratories, and in some cases the flight stations, contain the equipment to digitize the nanosecond detector signals on a time scale of a few microseconds. At this point, the data passes into the ORELA Data Acquisition portion of the ORELA Data Handling System. An introduction to the ORELA Data Acquisition System is given, and the component parts of the system are briefly reviewed. Each specifically designed piece of hardware is briefly described with a simplified block diagram. Modifications to standard peripheral devices are reviewed. A list of drawings and programming notes are also included

  20. Acquisition and treatment systems for experimental data

    International Nuclear Information System (INIS)

    Bouard, E.

    1988-01-01

    The acquisition and treatment systems for experimental data has been conceived to give a response to experimental requirements in a research reactor such OSIRIS. Its objective is to acquire and treat the ensemble of informations coming from one or many experiences, to archive useful data for an ulterior treatment and to give at the experimentator a tool ensemble for a better track of his experience. Its main characteristics are given in this text [fr

  1. Data acquisition system for radiographic imaging

    International Nuclear Information System (INIS)

    Lanza, R.C.; Votano, J.R.; Russ, T.

    1992-01-01

    This patent describes a continuous data acquisition system for radiographic imaging without interrupting acquisition activity the acquisition system. It comprises at least two memory means for storing radiographic data from a radiation detector wherein each of the memory means having a plurality of addressable memory locations and each of the memory means are such that the locations of the memory means correspond to spatial locations in the radiation detector; logic control means for sensing radiographic data transmitted by the radiation detector, for selecting one of the memory means for storage of the data, for transferring data to the selected memory means, and for switching form one memory means to another memory means according to a predefined schedule and according to memory capacity level, the logic control means further comprising a logic device which receives data and increments the contents of locations in a memory means in response to such data; and interface control means for reading data from one or the other memory means when such memory means is not actively acquiring data such that data can be acquired continuously by the system

  2. Acquisition system for the diagnostics data from a toroidal machine

    International Nuclear Information System (INIS)

    Moulin, B.

    1976-01-01

    The data acquisition system 'ARIANE' has been conceived by the SIG (Service d'Ionique Generale), for physical measurements on the toroidal machines PETULA and WEGA, which were designed to study the H.F. heating of pulsed plasmas. These systems are constitued of electronic modules which permit them to be adapted to different kinds of measurements, either by analogue channels or by pulse counting. The programmation of these systems, are achieved, either by multiswitches accessible manually on front panels, or by a computer which performs the numerical computations [fr

  3. The HyperCP data acquisition system

    International Nuclear Information System (INIS)

    Kaplan, D.M.

    1997-06-01

    For the HyperCP experiment at Fermilab, we have assembled a data acquisition system that records on up to 45 Exabyte 8505 tape drives in parallel at up to 17 MB/s. During the beam spill, data are acquired from the front-end digitization systems at ∼ 60 MB/s via five parallel data paths. The front-end systems achieve typical readout deadtime of ∼ 1 micros per event, allowing operation at 75-kHz trigger rate with approx-lt 30% deadtime. Event building and tapewriting are handled by 15 Motorola MVME167 processors in 5 VME crates

  4. The ngdp framework for data acquisition systems

    International Nuclear Information System (INIS)

    Isupov, A.Yu.

    2010-01-01

    The ngdp framework is intended to provide a base for the data acquisition (DAQ) system software. The ngdp's design key features are: high modularity and scalability; usage of the kernel context (particularly kernel threads) of the operating systems (OS), which allows one to avoid preemptive scheduling and unnecessary memory-to-memory copying between contexts; elimination of intermediate data storages on the media slower than the operating memory like hard disks, etc. The ngdp, having the above properties, is suitable to organize and manage data transportation and processing for needs of essentially distributed DAQ systems

  5. CAMAC data acquisition system for the pelletron

    International Nuclear Information System (INIS)

    Chatterjee, A.; Ghodgaonkar, M.D.; Khare, A.N.

    1993-01-01

    We have developed a CAMAC data acquisition system to meet the needs of a broad range of experiments at the pelletron. The system makes use of the DMA CAMAC crate controller CC3. The system is designed around two configurations. In the first, the crate controller is interfaced to an IBM PC/AT. The data are acquired on the PC Winchester disk. In the second configuration, the IBM PC is further linked to a HORIZON III mini-computer via ethernet. In this case list mode data can be taken directly on 1/2-inch reel tapes or 60MB cartridges. (author). 3 refs., 2 figs

  6. Embedded data acquisition system for neutron monitors

    International Nuclear Information System (INIS)

    Población, Ó G; Tejedor, I G; Sánchez, S; Blanco, J J; Gómez-Herrero, R; Medina, J; Steigies, C T

    2014-01-01

    This article presents the design and implementation of a new data acquisition system to be used as replacement for the old ones that have been in use with neutron monitors for the last decades and, which are eventually becoming obsolete. This new system is also intended to be used in new installations, enabling these scientific instruments to use today's communication networks to send data and receive commands from the operators. This system is currently running in two stations: KIEL2, in the Christian-Albrechts-Universität zu Kiel, Kiel, Germany, and CALMA, in the Castilla-La Mancha Neutron Monitor, Guadalajara, Spain

  7. Development of an automatic sample changer and a data acquisition system

    International Nuclear Information System (INIS)

    Bianchini, Ricardo M.; Estevez, Jorge; Vollmer, Alberto E.; Iglicki, Flora A.

    1999-01-01

    An automatic electro-pneumatic sample changer with a rotating sample holder is described. The changer is coupled through an electronic interface with the data acquisition station. The software to automate the system has been designed. (author)

  8. Distributed radiation data acquisition system for KAPP

    International Nuclear Information System (INIS)

    Narsaiah, A.; Anantakrishnan, T.S.; Bairi, B.R.

    1992-01-01

    Increased concern for the safety of personnel working in Nuclear Power Stations demands an efficient centralized Radiation Data Acquisition System (RADAS) to monitor different types of radiation at distributed locations of the plant. The system provides a comprehensive picture of radio-activity level distribution in the reactor building to facilitate prompt and correct decision making to take care of any emergency situation. The system is build around an industrial IBM-PC connected to remote intelligent data acquisition units using serial data communication links. To ensure high system availability and ease of maintenance the mechanical moving disk storage has been replaced by solid state memory storage (RAM Disk). Functional CRT displays have been substituted by the assembly of IBM-PC Mother Board with built-in firmware and standard TV Monitor. The computer handles a variety of processing functions which include the conversion to engineering units, checking of alarms, display/printing of plant radiation level status and system diagnostics. Intelligent terminals have been provided with graphic and text formatting capabilities. A hot standby computer connected to analog and digital inputs takes over the system functions on the failure of the host system. Modular software written in the higher level C-language runs under a standard real-time operating system Kernel. This provides for easy modification and expandability at site. Based on the experience of its commissioning at Kakrapar Power Station a new compact version is being designed for a specific application in another class of reactor. (author). 3 refs., 1 fig

  9. Jefferson Lab Data Acquisition Run Control System

    International Nuclear Information System (INIS)

    Vardan Gyurjyan; Carl Timmer; David Abbott; William Heyes; Edward Jastrzembski; David Lawrence; Elliott Wolin

    2004-01-01

    A general overview of the Jefferson Lab data acquisition run control system is presented. This run control system is designed to operate the configuration, control, and monitoring of all Jefferson Lab experiments. It controls data-taking activities by coordinating the operation of DAQ sub-systems, online software components and third-party software such as external slow control systems. The main, unique feature which sets this system apart from conventional systems is its incorporation of intelligent agent concepts. Intelligent agents are autonomous programs which interact with each other through certain protocols on a peer-to-peer level. In this case, the protocols and standards used come from the domain-independent Foundation for Intelligent Physical Agents (FIPA), and the implementation used is the Java Agent Development Framework (JADE). A lightweight, XML/RDF-based language was developed to standardize the description of the run control system for configuration purposes

  10. Development of signal acquisition device of rotating coil measurement system

    International Nuclear Information System (INIS)

    Zhou Jianxin; Li Li; Kang Wen; Deng Chengdong; Yin Baogui; Fu Shinian

    2013-01-01

    A new rotating coil magnetic measurement system using the technical solution of the combination of a dynamic signal acquisition card and software with specific functions was developed. The acquisition device of the system successfully implemented the function of the PDI-5025 integrator. The sampling rate, the range, the accuracy and the flexibility of the system were improved. The development program of signal acquisition equipment, the realization of the acquisition function and the reliability and stability of the system were introduced. (authors)

  11. Pattern-based framework for data acquisition systems

    International Nuclear Information System (INIS)

    Padmini, S.; Diwakar, M.P.; Nair, Preetha; Mathew, R.

    2004-01-01

    The data acquisition framework implements a reusable abstract architectural design for use in the development of data acquisition systems. The framework is being used to build Flux Mapping system (FMs) for TAPS III-IV and RRS Data Acquisition System for Dhruva reactor

  12. Tracking Electron Uptake from a Cathode into Shewanella Cells: Implications for Energy Acquisition from Solid-Substrate Electron Donors

    Directory of Open Access Journals (Sweden)

    Annette R. Rowe

    2018-02-01

    Full Text Available While typically investigated as a microorganism capable of extracellular electron transfer to minerals or anodes, Shewanella oneidensis MR-1 can also facilitate electron flow from a cathode to terminal electron acceptors, such as fumarate or oxygen, thereby providing a model system for a process that has significant environmental and technological implications. This work demonstrates that cathodic electrons enter the electron transport chain of S. oneidensis when oxygen is used as the terminal electron acceptor. The effect of electron transport chain inhibitors suggested that a proton gradient is generated during cathode oxidation, consistent with the higher cellular ATP levels measured in cathode-respiring cells than in controls. Cathode oxidation also correlated with an increase in the cellular redox (NADH/FMNH2 pool determined with a bioluminescence assay, a proton uncoupler, and a mutant of proton-pumping NADH oxidase complex I. This work suggested that the generation of NADH/FMNH2 under cathodic conditions was linked to reverse electron flow mediated by complex I. A decrease in cathodic electron uptake was observed in various mutant strains, including those lacking the extracellular electron transfer components necessary for anodic-current generation. While no cell growth was observed under these conditions, here we show that cathode oxidation is linked to cellular energy acquisition, resulting in a quantifiable reduction in the cellular decay rate. This work highlights a potential mechanism for cell survival and/or persistence on cathodes, which might extend to environments where growth and division are severely limited.

  13. Tracking Electron Uptake from a Cathode into Shewanella Cells: Implications for Energy Acquisition from Solid-Substrate Electron Donors

    Science.gov (United States)

    Rajeev, Pournami; Jain, Abhiney; Pirbadian, Sahand; Okamoto, Akihiro; Gralnick, Jeffrey A.; El-Naggar, Mohamed Y.; Nealson, Kenneth H.

    2018-01-01

    ABSTRACT While typically investigated as a microorganism capable of extracellular electron transfer to minerals or anodes, Shewanella oneidensis MR-1 can also facilitate electron flow from a cathode to terminal electron acceptors, such as fumarate or oxygen, thereby providing a model system for a process that has significant environmental and technological implications. This work demonstrates that cathodic electrons enter the electron transport chain of S. oneidensis when oxygen is used as the terminal electron acceptor. The effect of electron transport chain inhibitors suggested that a proton gradient is generated during cathode oxidation, consistent with the higher cellular ATP levels measured in cathode-respiring cells than in controls. Cathode oxidation also correlated with an increase in the cellular redox (NADH/FMNH2) pool determined with a bioluminescence assay, a proton uncoupler, and a mutant of proton-pumping NADH oxidase complex I. This work suggested that the generation of NADH/FMNH2 under cathodic conditions was linked to reverse electron flow mediated by complex I. A decrease in cathodic electron uptake was observed in various mutant strains, including those lacking the extracellular electron transfer components necessary for anodic-current generation. While no cell growth was observed under these conditions, here we show that cathode oxidation is linked to cellular energy acquisition, resulting in a quantifiable reduction in the cellular decay rate. This work highlights a potential mechanism for cell survival and/or persistence on cathodes, which might extend to environments where growth and division are severely limited. PMID:29487241

  14. AZ-101 Mixer Pump Demonstration Data Acquisition System and Gamma Cart Data Acquisition Control System Software Configuration Management Plan

    International Nuclear Information System (INIS)

    WHITE, D.A.

    1999-01-01

    This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS)

  15. Electronic theodolite intersection systems

    OpenAIRE

    Bingley, R. M.

    1990-01-01

    The development of electronic surveying instruments, such as electronic theodolites, and concurrent advances in computer technology, has revolutionised engineering surveying; one of the more recent examples being the introduction of Electronic Theodolite Intersection Systems (ETISs). An ETIS consists of two or more electronic theodolites and a computer, with peripheral hardware and suitable software. The theoretical principles on which they are based have been known for a long time, but ...

  16. A data acquisition work station for ORELA [Oak Ridge Electron Linear Accelerator

    International Nuclear Information System (INIS)

    Rooney, B.D.; Todd, J.H.; Spencer, R.R.; Weston, L.W.

    1990-09-01

    A new multiparameter data acquisition system has been developed and fabricated at the Oak Ridge Electron Linear Accelerator (ORELA) which utilizes an IBM PS/2 Model 80 personal computer and data handler with a 2048 word buffer. The acquisition system can simultaneously acquire data from one, two, or three digitizers, multiplex up to four detectors, read and control up to 16 scalers, and output 32 DC logic signals which can be used to control external instrumentation. Software has been developed for the OS/2 operating system, supporting multiparameter data storage for up to three million channels with the capability of collecting data in a background mode, to make the computer available for other tasks while collecting data. The system also supports multiparameter biasing and can collect, crunch, and store data at rates as high as 30,000 events per second

  17. Automated system for data acquisition and monitoring

    Directory of Open Access Journals (Sweden)

    Borza Sorin

    2017-01-01

    Full Text Available The Environmental management has become, with the development of human society a very important issue. There have been multiple systems that automatically monitors the environment. In this paper we propose a system that integrates GIS software and data acquisition software. In addition the proposed system implements new AHP multicriteria method that can get an answer online on each pollutant influence on limited geographical area in which the monitors. Factors pollutants of limited geographical areas are taken automatically by specific sensors through acquisition board. Labview software, with virtual instrument created by transferring them into a database Access. Access database they are taken up by software Geomedia Professional and processed using multi-criteria method AHP, so that at any moment, their influence on the environment and classify these influences, can be plotted on the screen monitoring system. The system allows, the automatic collection of data, the memorization and the generation of GIS elements. The research presented in this paper were aimed at implementing multi-criteria methods in GIS software.

  18. CAMAC data acquisition system based on micro VAXII

    International Nuclear Information System (INIS)

    Yin Xijin; Shen Cuihua; Bai Xiaowei; Li Weisheng

    1993-01-01

    The CAMAC data acquisition system based on Micro VAXII Computer provides high-speed, Zero-suppressed, and 256-parameter CAMAC acquisition. It consists of three parts: control logic unit, CAMAC readout system and host computer system. When the control logical unit is triggered by external electronic selection signal, it produces a pilot signal to keep all of the parameters of a particular event together. Event-model data have been collected by using a CAMAC Fast Crate controller. The host computer system, in hard environment, is equipped with certain peripheral device. It includes the following: 1. at least two M990 GCR, 6250B/inch, magnetic tape driver operating at 75 inches per second or faster; 2. a Tektronix 4014 storage scope; 3. a laser printer, LND3-AE or copier which is capable of making hard-copies of Tektronix 4014 screen; 4. a control console device and a line printer; 5. x-press color graphics terminal; 6. DEC network. When the system is in real-time acquisition, it is able, on-line, to handle and analyse data stream, to monitor and control experiment and to display dynamically spectra on the Tektronix 4014

  19. Auxiliary controllers for data acquisition from scintillation detector electronic equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leonenko, D A; Rybakov, V G; Sen' ko, V A [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Serpukhov. Inst. Fiziki Vysokikh Ehnergij

    1983-01-01

    Structural schemes of auxiliary controllers of three types ensuring compression, filtration and record in buffer storage of data from scintillation detectors electronic equipment are described. The electronics is made according to the CAMAC ideology. The KD-85 controller exercises data readout from analog-to-digital converters (ADC), subtraction of pedestal values, discrimination by the bottom level and record into the buffer storage module. The KD-86 controller summarizes data from all the ADC channels in a crate dicscriminates the summarized data by the upper and bottom levels, and rejects data classified as useless. The KD-90 controller ensures data reading from different modules of the crate according to preset code and records information in the buffer storage module. The considered controllers employ integral microcircuits of the K 155 series. At present the controllers are under experimental operation. Their utilization would permit to adopt new arrangement of data acquisition from experimental facilities in the nearest future and essentially increase the operating efficiency of these facilities.

  20. MFTF plasma diagnostics data acquisition system

    International Nuclear Information System (INIS)

    Davis, G.E.; Coffield, F.E.

    1979-01-01

    The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982

  1. Multichannel long period seismic data acquisition system

    International Nuclear Information System (INIS)

    Kolvankar, V.G.; Rao, D.S.

    1990-01-01

    This paper discusses the specifications and performance of an eight channel long period seismic digital data acquisition system, which is developed and installed at Seismic Array Station, Gauribidanur, Karnataka State. The paper describes how these data in an unedited form are recorded on a single track of magnetic tape inter-mittantly, which has resulted in recording of 50 days data on a single tapespool. A time indexing technique which enables quick access to any desired portion of a recorded tape is also discussed. Typical examples of long period seismic event signals recorded by this system are also illustrated. Various advantages, the system provides over the analog multichannel instrumentation tape recording system, operating at Seismic Array Station for th e last two decades, are also discussed. (author). 7 figs

  2. An Effective 3D Ear Acquisition System.

    Directory of Open Access Journals (Sweden)

    Yahui Liu

    Full Text Available The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  3. DATA ACQUISITION FOR SNS BEAM LOSS MONITOR SYSTEM

    International Nuclear Information System (INIS)

    YENG, Y.; GASSNER, D.; HOFF, L.; WITKOVER, R.

    2003-01-01

    The Spallation Neutron Source (SNS) beam loss monitor system uses VME based electronics to measure the radiation produced by lost beam. Beam loss signals from cylindrical argon-filled ion chambers and neutron detectors will be conditioned in analog front-end (AFE) circuitry. These signals will be digitized and further processed in a dedicated VME crate. Fast beam inhibit and low-level, long-term loss warnings will be generated to provide machine protection. The fast loss data will have a bandwidth of 35kHz. While the low level, long-term loss data will have much higher sensitivity. This is further complicated by the 3 decade range of intensity as the Ring accumulates beam. Therefore a bandwidth of 100kHz and dynamic range larger than 21 bits data acquisition system will be required for this purpose. Based on the evaluation of several commercial ADC modules in preliminary design phase, a 24 bits Sigma-Delta data acquisition VME bus card was chosen as the SNS BLM digitizer. An associated vxworks driver and EPICS device support module also have been developed at BNL. Simulating test results showed this system is fully qualified for both fast loss and low-level, long-term loss application. The first prototype including data acquisition hardware setup and EPICS software (running database and OPI clients) will be used in SNS Drift Tube Linac (DTL) system commissioning

  4. A Data Acquisition System for Medical Imaging

    International Nuclear Information System (INIS)

    Abellan, Carlos; Cachemiche, Jean-Pierre; Rethore, Frederic; Morel, Christian

    2013-06-01

    A data acquisition system for medical imaging applications is presented. Developed at CPPM, it provides high performance generic data acquisition and processing capabilities. The DAQ system is based on the PICMG xTCA standard and is composed of 1 up to 10 cards in a single rack, each one with 2 Altera Stratix IV FPGAs and a Fast Mezzanine Connector (FMC). Several mezzanines have been produced, each one with different functionalities. Some examples are: a mezzanine capable of receiving 36 optical fibres with up to 180 Gbps sustained data rates or a mezzanine with 12 x 5 Gbps input links, 12 x 5 Gbps output links and an SFP+ connector for control purposes. Several rack sizes are also available, thus making the system scalable from a one card desktop system useful for development purpose up to a full featured rack mounted DAQ for high end applications. Depending on the application, boards may exchange data at speeds of up to 25.6 Gbps bidirectional sustained rates in a double star topology through back-plane connections. Also, front panel optical fibres can be used when higher rates are required by the application. The system may be controlled by a standard Ethernet connection, thus providing easy integration with control computers and avoiding the need for drivers. Two control systems are foreseen. A Socket connection provides easy interaction with automation software regardless of the operating system used for the control PC. Moreover a web server may run on the Envision cards and provide an easy intuitive user interface. The system and its different components will be introduced. Some preliminary measurements with high speed signal links will be presented as well as the signal conditioning used to allow these rates. (authors)

  5. Human Robotic Systems (HRS): Robotic ISRU Acquisition Element

    Data.gov (United States)

    National Aeronautics and Space Administration — During 2014, the Robotic ISRU Resource Acquisition project element will develop two technologies:Exploration Ground Data Systems (xGDS)Sample Acquisition on...

  6. Remote data acquisition system based on MSM7512B8

    International Nuclear Information System (INIS)

    Jiang Junfeng

    2003-01-01

    This paper introduces a remote data acquisition system based on MC68HC908GP32 and MSM7512B, which can accomplish remote data communications on telephone network, and realize remote data acquisition. (authors)

  7. Analysis of System Training Impact for Major Defense Acquisition Programs (MDAPs): Training Systems Acquisition

    Science.gov (United States)

    2012-07-01

    Training Systems Acquisition IDA Document D-4648 Log: H 12-001032 July 2012 Approved for public release; distribution is unlimited...Background The Patriot system began because of the need to replace an aging and limited air defense system in the 1970s, the Nike -Hercules, and...simulation technology, embedded training and distributed learning (DoD Instruction 1322.26), and instrumentation systems that provide “anytime, anyplace

  8. A prototype switched Ethernet data acquisition system

    International Nuclear Information System (INIS)

    Ye Gaoying; Deng Huichen; Chen Liaoyuan; Liu Li; Wang Xinhui

    1999-01-01

    A prototype switched Ethernet data acquisition system has been built up and successfully operated in HL-1M tokamak experiments. The system is based on a switched high bandwidth Ethernet network with which the CAMAC crates are directly interfaced. It takes the advanced features of LAN switch and Ethernet CAMAC controller (ECC 1365 MK III, HYTEC product) to avoid the rewriting of CAMAC driver for an individual computer system and to ensure high data transmission rate between CAMAC system and host computers on the network. It is a new approach to DAS system architecture and provides a solution for a well-known bottleneck problem in traditional distributed DAS system for fusion research. An average throughput of the test system reaches over 100 Mbps. The system features also an easy and low cost migration from traditional distributed DAS system. In the paper, the hardware configuration, software structure, performance of the system and the method of migrating from current DAS system are discussed in detail. (orig.)

  9. Multiparameter nuclear data acquisition and processing system

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, M; Turzo, I; Kristiak, J; Matousek, V [Inst. of Physics, Slovak Academy of Sciences, Bratislava (Slovakia)

    1996-12-31

    A modular system to determine correlations among many detection in radiation measurements is described. The capabilities of the system are illustrated of correlation between positron annihilation life-time and the momentum of electron-positron pairs using four detectors. 8 refs.

  10. Instrumentation & Data Acquisition System (D AS) Engineer

    Science.gov (United States)

    Jackson, Markus Deon

    2015-01-01

    The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

  11. 2XIIB computer data acquisition system

    International Nuclear Information System (INIS)

    Tyler, G.C.

    1975-01-01

    All major plasma diagnostic measurements from the 2XIIB experiment are recorded, digitized, and stored by the computer data acquisition system. The raw data is then examined, correlated, reduced, and useful portions are quickly retrieved which direct the future conduct of the plasma experiment. This is done in real time and on line while the data is current. The immediate availability of this pertinent data has accelerated the rate at which the 2XII personnel have been able to gain knowledge in the study of plasma containment and fusion interaction. The up time of the experiment is being used much more effectively than ever before. This paper describes the hardware configuration of our data system in relation to various plasma parameters measured, the advantages of powerful software routines to reduce and correlate the data, the present plans for expansion of the system, and the problems we have had to overcome in certain areas to meet our original goals

  12. Shigella Iron Acquisition Systems and their Regulation.

    Science.gov (United States)

    Wei, Yahan; Murphy, Erin R

    2016-01-01

    Survival of Shigella within the host is strictly dependent on the ability of the pathogen to acquire essential nutrients, such as iron. As an innate immune defense against invading pathogens, the level of bio-available iron within the human host is maintained at exceeding low levels, by sequestration of the element within heme and other host iron-binding compounds. In response to sequestration mediated iron limitation, Shigella produce multiple iron-uptake systems that each function to facilitate the utilization of a specific host-associated source of nutrient iron. As a mechanism to balance the essential need for iron and the toxicity of the element when in excess, the production of bacterial iron acquisition systems is tightly regulated by a variety of molecular mechanisms. This review summarizes the current state of knowledge on the iron-uptake systems produced by Shigella species, their distribution within the genus, and the molecular mechanisms that regulate their production.

  13. A triggerless digital data acquisition system for nuclear decay experiments

    Energy Technology Data Exchange (ETDEWEB)

    Agramunt, J.; Tain, J. L.; Albiol, F.; Algora, A.; Estevez, E.; Giubrone, G.; Jordan, M. D.; Molina, F.; Rubio, B.; Valencia, E. [Instituto de Fisica Corpuscular, Centro Mixto C.S.I.C. - Univ. Valencia, Apdo. Correos 22085, 46071 Valencia (Spain)

    2013-06-10

    In nuclear decay experiments an important goal of the Data Acquisition (DAQ) system is to allow the reconstruction of time correlations between signals registered in different detectors. Classically DAQ systems are based in a trigger that starts the event acquisition, and all data related with the event of that trigger are collected as one compact structure. New technologies and electronics developments offer new possibilities to nuclear experiments with the use of sampling ADC-s. This type of ADC-s is able to provide the pulse shape, height and a time stamp of the signal. This new feature (time stamp) allows new systems to run without an event trigger. Later, the event can be reconstructed using the time stamp information. In this work we present a new DAQ developed for {beta}-delayed neutron emission experiments. Due to the long moderation time of neutrons, we opted for a self-trigger DAQ based on commercial digitizers. With this DAQ a negligible acquisition dead time was achieved while keeping a maximum of event information and flexibility in time correlations.

  14. Multisensory experiments and data acquisition systems on the meson facilities

    International Nuclear Information System (INIS)

    Bystritskij, V.M.

    2000-01-01

    The paper describes some of the multisensory experiments performed or being performed at the meson factories PSI (Switzerland), TRIUMF (Canada), LAMPF (USA), KEK (Japan), RAL (England) in order to investigate the fundamental processes in elementary particle physics. Designs of various detectors are briefly reviewed, the organizational ideology and the structure of the recording electronics and data acquisition systems for these experiments are considered. The ideology underlying the off-line analysis software is touched upon and the most important results of the investigations at meson factories are given

  15. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  16. A control system for a free electron laser experiment

    International Nuclear Information System (INIS)

    Giove, D.

    1992-01-01

    The general layout of a control and data acquisition system for a Free Electron Laser experiment will be discussed. Some general considerations about the requirements and the architecture of the whole system will be developed. (author)

  17. Characterization of an electronic system for Image acquisition portal to open field dosimetry; Caracterizacao de um sistema eletronico de aquisicao de imagem portal para dosimetria em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Barbi, Gustavo L.; Oliveira, Harley F.; Bertucci, Edenyse C.; Amaral, Leonardo L.; Borges, Leandro F., E-mail: gustavobarbi@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica

    2012-08-15

    The objective was to characterize and enable an electronic portal imaging device (EPID) to use like a portal dosimetry device - PDI, in non-transit mode, without interposition of scattering between the beam and EPID for measurement to open fields. The images as well as the DICOM header data are extracted from software ImageJ and the information are used in the basic algorithm for converting pixel to dose. The linearity and reproducibility of response were analyzed, and the maximum deviation found of 2,3% to 800 monitor units (MU) for linearity and -0,9% for reproducibility of signal measured daily. A 512x512 matrix with a resolution of 0,8mm was established to restore the shape of beam from the image. The field size dependence was evaluated, by obtaining the ratio of total scattering of ionization chamber and EPID. Finally, a calibration factor of 28470.88{+-}170.73 pixel/cGy was established for the central area of the image. Comparative analyzes between the PDI, radiochromic film and array of ionization chambers (MatriXX) showed good agreement for fields greater then 5 x 5 cm{sup 2} to reestablishment of form field and dose, however, for fields between 3x3 cm{sup 2} and 5x5 cm{sup 2}, the agreement to shape of beam was best established by film. (author)

  18. Options for Next Generation Digital Acquisition Systems

    CERN Document Server

    Boccardi, A

    2011-01-01

    Digital acquisition system designers have an always increasing number of options in terms of bus standards and digital signal processing hardware among which to choose. This allows for high flexibility but also opens the door to a proliferation of different architectures, potentially limiting the reusability and the design synergies among the various instrumentation groups. This contribution illustrates the design trends in some of the major institutes around the world with design examples including VME, PCI and TCA based modular systems using AMC and/or FMC mezzanines. Some examples of FPGA design practices aimed at increasing reusability of code will be mentioned together with some of the tools already available to designers to improve the information exchange and collaboration, like the Open Hardware Repository project.

  19. Nike Facility Diagnostics and Data Acquisition System

    Science.gov (United States)

    Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim

    2013-10-01

    The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.

  20. Experiences at HERA with the H1 data acquisition system

    International Nuclear Information System (INIS)

    Haynes, W.J.

    1992-09-01

    The recently commissioned HERA collider provides a significant pointer to the problems that have to be surmounted in data acquisition systems at the next generation of hadron machines. With bunch crossings, between 30 GeV electrons and 820 GeV protons, 96 nanoseconds apart, the H1 experiment illustrates the application of sophisticated pipelining solutions in the readout of several hundred thousand electronic channels. A modular, multiprocessor design structure emphasis the architectural concepts necessary to cope with large data throughput and yet remain flexible enough to exploit ongoing technological advances in both hardware and software. The range of techniques implemented will be surveyed, covering various digitisation solutions at the front-end through to embedded microprocessor arrays in standard busses controlled by graphics-based stations executing object- orientated code. The experiences gained in developing such a system are also discussed. (orig.)

  1. Synchronization and sequencing of data acquisition and control electronics at the European X-ray free electron laser

    International Nuclear Information System (INIS)

    Gessler, Patrick

    2015-11-01

    The 3.5 km long European X-Ray Free Electron Laser, currently under construction in northern Germany, will deliver bursts of up to 2700 short X-ray pulses every 100 ms, providing wavelengths between 0.05 and 6 nm, and a repetition rate of 4.5 MHz to several experiment stations. It allows in-depth research in various scientific fields. In order to set-up the beam, position samples and capture the measured variables, information from the accelerator, diagnostic devices and detectors have to be digitized, converted, processed, transferred, concentrated, distributed, reorganized, controlled and saved. All these steps have to be accurately synchronized and sequenced relative to the actual electron bunch or photon pulse in order to guarantee correct data acquisition timings and unique identification of each bunch passing the beamlines. This document provides a complete description of the planning, design, realization and evaluation of the European XFEL Timing System, which implements the synchronization and sequencing of the data acquisition and control electronics for the European X-Ray Free-Electron Laser Facility.

  2. Electronics circuits and systems

    CERN Document Server

    Bishop, Owen

    2007-01-01

    The material in Electronics - Circuits and Systems is a truly up-to-date textbook, with coverage carefully matched to the electronics units of the 2007 BTEC National Engineering and the latest AS and A Level specifications in Electronics from AQA, OCR and WJEC. The material has been organized with a logical learning progression, making it ideal for a wide range of pre-degree courses in electronics. The approach is student-centred and includes: numerous examples and activities; web research topics; Self Test features, highlighted key facts, formulae and definitions. Each chapter ends with a set

  3. Electronics circuits and systems

    CERN Document Server

    Bishop, Owen

    2011-01-01

    The material in Electronics - Circuits and Systems is a truly up-to-date textbook, with coverage carefully matched to the electronics units of the 2007 BTEC National Engineering and the latest AS and A Level specifications in Electronics from AQA, OCR and WJEC. The material has been organized with a logical learning progression, making it ideal for a wide range of pre-degree courses in electronics. The approach is student-centred and includes: numerous examples and activities; web research topics; Self Test features, highlighted key facts, formulae and definitions. Ea

  4. The MDSplus data acquisition system, current status and future directions

    International Nuclear Information System (INIS)

    Stillerman, J.; Fredian, T.W.

    1999-01-01

    The MDSplus data acquisition system was developed in collaboration with the ZTH group at Los Alamos National Laboratory and the RFX group at CNR in Padua, Italy and is currently in use at MIT, RFX in Padua, and TCV at EPFL in Lausanne. MDSplus is based on a hierarchical experiment description which completely describes the data acquisition and analysis tasks and contains the results from these operations. It also includes a set of X/motif based tools for data acquisition and display, as well as diagnostic configuration and management. These tools were designed to operate in a distributed, client/server environment with multiple concurrent readers and writers to the data store. An interface to a relational database is provided for storage and management of processed data. A commercially available package called IDL is used as the primary data analysis and visualization tool. The current projects include a new interface to the electronic logbook, tools for remote collaborators and WWW access, and a port of the system to UNIX and Windows-NT/95. (orig.)

  5. Data acquisition system realization for H1 experiment

    International Nuclear Information System (INIS)

    Del Buono, L.

    1989-06-01

    The acquisition and trigger system for H1 liquid argon calorimeter deals with severe constraints which have to be taken into account. We describe the system which results from these constraints, emphasizing the solutions adopted to meet the specificities of the detector and the difficult experimental conditions at HERA: high physical background (10 4-5 Hz), physics and background events pile up (10%), large crossing frequency of proton and electron bunches (10.4 MHz). Next, we present a detailed description of the acquisition and online control scheme used during the calorimetry tests in SPS beam, at CERN. This test system, prefiguring the final one (which will start to work at the end of 1989), includes a fast frontal processor CAB (taking charge of the electronics read out and sequencing, and furthermore producing simple histograms). The CAB is controlled by a Micro Vax computer which realizes the user interface, allowing a quick visualisation and verification of the acquired data, these functions being performed in multitasking environment [fr

  6. CODA: A scalable, distributed data acquisition system

    International Nuclear Information System (INIS)

    Watson, W.A. III; Chen, J.; Heyes, G.; Jastrzembski, E.; Quarrie, D.

    1994-01-01

    A new data acquisition system has been designed for physics experiments scheduled to run at CEBAF starting in the summer of 1994. This system runs on Unix workstations connected via ethernet, FDDI, or other network hardware to multiple intelligent front end crates -- VME, CAMAC or FASTBUS. CAMAC crates may either contain intelligent processors, or may be interfaced to VME. The system is modular and scalable, from a single front end crate and one workstation linked by ethernet, to as may as 32 clusters of front end crates ultimately connected via a high speed network to a set of analysis workstations. The system includes an extensible, device independent slow controls package with drivers for CAMAC, VME, and high voltage crates, as well as a link to CEBAF accelerator controls. All distributed processes are managed by standard remote procedure calls propagating change-of-state requests, or reading and writing program variables. Custom components may be easily integrated. The system is portable to any front end processor running the VxWorks real-time kernel, and to most workstations supplying a few standard facilities such as rsh and X-windows, and Motif and socket libraries. Sample implementations exist for 2 Unix workstation families connected via ethernet or FDDI to VME (with interfaces to FASTBUS or CAMAC), and via ethernet to FASTBUS or CAMAC

  7. STADUS - Ultrasonic data acquisition and processing system

    International Nuclear Information System (INIS)

    Saglio, Robert; Birac, A.M.; Frappier, J.C.

    1982-05-01

    The CEA (Commissariat a l'Energie Atomique) has developed a system for the acquisition and analysis of data recorded during ultrasonic testing. Initially this system was designed and built for the needs of in-service inspection of PWR type power reactors. It is in far wider use today for miscellaneous automatic ultrasonic inspection procedures. This system records, in digital form, the ultrasonic data supplied by the transducers (maximum 16 simultaneous channels), and the geometric coordinates defining the position of the inspection tool. Based on these data, which are recorded on floppy disk, this system helps to display data in the form of A SCAN, B SCAN and C SCAN images. In addition, processing programs of data transfer from the STADUS floppy disks have been developed and inserted on computers more powerful than the one used in the STADUS system. These programs serve to obtain different fault charts on an adjustable scale, as well as listings concerning the defect positions and dimensions [fr

  8. NOTE: A method for controlling image acquisition in electronic portal imaging devices

    Science.gov (United States)

    Glendinning, A. G.; Hunt, S. G.; Bonnett, D. E.

    2001-02-01

    Certain types of camera-based electronic portal imaging devices (EPIDs) which initiate image acquisition based on sensing a change in video level have been observed to trigger unreliably at the beginning of dynamic multileaf collimation sequences. A simple, novel means of controlling image acquisition with an Elekta linear accelerator (Elekta Oncology Systems, Crawley, UK) is proposed which is based on illumination of a photodetector (ORP-12, Silonex Inc., Plattsburgh, NY, USA) by the electron gun of the accelerator. By incorporating a simple trigger circuit it is possible to derive a beam on/off status signal which changes at least 100 ms before any dose is measured by the accelerator. The status signal does not return to the beam-off state until all dose has been delivered and is suitable for accelerator pulse repetition frequencies of 50-400 Hz. The status signal is thus a reliable means of indicating the initiation and termination of radiation exposure, and thus controlling image acquisition of such EPIDs for this application.

  9. Accelerator optimization using a network control and acquisition system

    International Nuclear Information System (INIS)

    Geddes, Cameron G.R.; Catravas, P.E.; Faure, Jerome; Toth, Csaba; Tilborg, J. van; Leemans, Wim P.

    2002-01-01

    Accelerator optimization requires detailed study of many parameters, indicating the need for remote control and automated data acquisition systems. A control and data acquisition system based on a network of commodity PCs and applications with standards based inter-application communication is being built for the l'OASIS accelerator facility. This system allows synchronous acquisition of data at high (> 1 Hz) rates and remote control of the accelerator at low cost, allowing detailed study of the acceleration process

  10. Data acquisition system issues for large experiments

    International Nuclear Information System (INIS)

    Siskind, E.J.

    2007-01-01

    This talk consists of personal observations on two classes of data acquisition ('DAQ') systems for Silicon trackers in large experiments with which the author has been concerned over the last three or more years. The first half is a classic 'lessons learned' recital based on experience with the high-level debug and configuration of the DAQ system for the GLAST LAT detector. The second half is concerned with a discussion of the promises and pitfalls of using modern (and future) generations of 'system-on-a-chip' ('SOC') or 'platform' field-programmable gate arrays ('FPGAs') in future large DAQ systems. The DAQ system pipeline for the 864k channels of Si tracker in the GLAST LAT consists of five tiers of hardware buffers which ultimately feed into the main memory of the (two-active-node) level-3 trigger processor farm. The data formats and buffer volumes of these tiers are briefly described, as well as the flow control employed between successive tiers. Lessons learned regarding data formats, buffer volumes, and flow control/data discard policy are discussed. The continued development of platform FPGAs containing large amounts of configurable logic fabric, embedded PowerPC hard processor cores, digital signal processing components, large volumes of on-chip buffer memory, and multi-gigabit serial I/O capability permits DAQ system designers to vastly increase the amount of data preprocessing that can be performed in parallel within the DAQ pipeline for detector systems in large experiments. The capabilities of some currently available FPGA families are reviewed, along with the prospects for next-generation families of announced, but not yet available, platform FPGAs. Some experience with an actual implementation is presented, and reconciliation between advertised and achievable specifications is attempted. The prospects for applying these components to space-borne Si tracker detectors are briefly discussed

  11. Design of data acquisition system for GEM detector

    International Nuclear Information System (INIS)

    Lu Jianliang; Chen Ziyu; Shen Ji; Jin Xi

    2011-01-01

    It describes the design and realization of the USB 2.0 high speed data acquisition devise which is used in the readout electronics of the GEM (gas electron multiplier) detector. By using of the USB Microcontroller EZ-USB FX2 CY7C68013A, high speed ADC and FPGA, high-speed data rate of data acquisition and transmission was realized. The data rate reaches to 20 MByte/s, meeting the requirements of data acquisition and transmission of the detector. (authors)

  12. Electro-Optical Data Acquisition and Tracking System

    Data.gov (United States)

    Federal Laboratory Consortium — The Electro-Optical Data Acquisition and Tracking System (EDATS) dynamically tracks and measures target signatures. It consists of an instrumentation van integrated...

  13. Defense Contract Management Command Support to System Acquisition Program Managers

    National Research Council Canada - National Science Library

    1999-01-01

    .... This report discusses the planning of contract administration office support to system acquisition program managers through the program integration process and the customer support outreach program...

  14. MIDAS [Master Information and Data Acquisition System

    International Nuclear Information System (INIS)

    Ball, D.L.

    1986-01-01

    The Master Information and Data Acquisition System (MIDAS) is a computerized work control system that provides 24-hour, real-time access to plant equipment information and work package status. It is used in the 400 Area of the Department of Energy (DOE) Hanford Site in Richland, Washington. MIDAS was originally created to aid in the release and control of work at the Fast Flux Test Facility (FFTF), which is operated by the Westinghouse Hanford Company for the DOE. After MIDAS performed that function at FFTF successfully for over two years, its role was expanded to provide similar functions for other facilities supporting the LMR mission. Through its ability to provide online, accurate information on plant components, safety criteria, and work package status, MIDAS reinforces Operations functions and the control and authorization of maintenance activities in the FFTF plant and in other related facilities. Thus, MIDAS enhances the operational safety, as well as the planning and scheduling process for these facilities. MIDAS consists of three parts: The Plant Tracking System (PTS), the Work Control Log (WCL), and the MIDAS Component Indices

  15. The LHCb trigger and data acquisition system

    CERN Document Server

    Dufey, J P; Harris, F; Harvey, J; Jost, B; Mato, P; Müller, E

    2000-01-01

    The LHCb experiment is the most recently approved of the 4 experiments under construction at CERNs LHC accelerator. It is a special purpose experiment designed to precisely measure the CP violation parameters in the B-B system. Triggering poses special problems since the interesting events containing B-mesons are immersed in a large background of inelastic p-p reactions. We therefore decided to implement a 4 level triggering scheme. The LHCb Data Acquisition (DAQ) system will have to cope with an average trigger rate of ~40 kHz, after two levels of hardware triggers, and an average event size of ~100 kB. Thus an event-building network which can sustain an average bandwidth of 4 GB/s is required. A powerful software trigger farm will have to be installed to reduce the rate from the 40 kHz to ~100 Hz of events written to permanent storage. In this paper we outline the general architecture of the Trigger and DAQ system and the readout protocols we plan to implement. First results of simulations of the behavior o...

  16. BEPCII electronic logbook system

    International Nuclear Information System (INIS)

    Liu Shu; Zhao Jijiu; Wang Chunhong

    2007-01-01

    According to demands of BEPCII construction and future operation, we are going to supply an open electronic logbook platform for people to record their message in developing and running BEPCII, and browse the log-book on website. That gives people an open and transparent logbook, rather than traditional paper notebook. With the template of DESY's Elogbook, the BEPCII electronic logbook was developed, using the popular JSP technology to develop dynamic Web applications. This paper will introduce the development of BEPCII electronic logbook system. (authors)

  17. Electronic components and systems

    CERN Document Server

    Dennis, W H

    2013-01-01

    Electronic Components and Systems focuses on the principles and processes in the field of electronics and the integrated circuit. Covered in the book are basic aspects and physical fundamentals; different types of materials involved in the field; and passive and active electronic components such as capacitors, inductors, diodes, and transistors. Also covered in the book are topics such as the fabrication of semiconductors and integrated circuits; analog circuitry; digital logic technology; and microprocessors. The monograph is recommended for beginning electrical engineers who would like to kn

  18. $ANBA; a rapid, combined data acquisition and correction program for the SEMQ electron microprobe

    Science.gov (United States)

    McGee, James J.

    1983-01-01

    $ANBA is a program developed for rapid data acquisition and correction on an automated SEMQ electron microprobe. The program provides increased analytical speed and reduced disk read/write operations compared with the manufacturer's software, resulting in a doubling of analytical throughput. In addition, the program provides enhanced analytical features such as averaging, rapid and compact data storage, and on-line plotting. The program is described with design philosophy, flow charts, variable names, a complete program listing, and system requirements. A complete operating example and notes to assist in running the program are included.

  19. Triggering, front-end electronics, and data acquisition for high-rate beauty experiments

    International Nuclear Information System (INIS)

    Johnson, M.; Lankford, A.J.

    1988-04-01

    The working group explored the feasibility of building a trigger and an electronics data acquisition system for both collider and fixed target experiments. There appears to be no fundamental technical limitation arising from either the rate or the amount of data for a collider experiment. The fixed target experiments will likely require a much higher rate because of the smaller cross section. Rates up to one event per RF bucket (50 MHz) appear to be feasible. Higher rates depend on the details of the particular experiment and trigger. Several ideas were presented on multiplicity jump and impact parameter triggers for fixed target experiments. 14 refs., 3 figs

  20. Multi-channel data acquisition system for CT

    International Nuclear Information System (INIS)

    Cao Fuqiang; He Bin; Liu Guohua; Xu Minjian

    2009-01-01

    The architecture design and realization of a data acquisition system for multi-channel CT is described. The article introduces the conversion of analog signal to digital signal, the data cache and transmission. This data acquisition system can be widely used in the system which requires the multi-channel, weak current signal detection. (authors)

  1. A data acquisition system based on PC-CAMAC BUS

    International Nuclear Information System (INIS)

    Xie Xiangyang; Jiang Haiyan; Luo Jiarong; Ji Zhenshan

    2000-08-01

    The author introduces a Data Acquisition System applied to HT-7 (a superconduction Tokamak device). The system is based on the CAMAC standard and the personal computer. The software has been written in C language. The system performs the following tasks: setup parameters of modules, data acquisition, disk data storage and their display

  2. Electronics a systems approach

    CERN Document Server

    Storey, Neil

    2017-01-01

    Electronics plays a central role in our everyday lives. It is at the heart of almost all of today's essential technology, from mobile phones to computers and from cars to power stations. As such, all engineers, scientists and technologists need to have a fundamental understanding of this exciting subject, and for many this will just be the beginning. Now in its sixth edition, Electronics: A Systems Approach provides an outstanding introduction to this fast-moving and important field. Comprehensively revised and updated to cover the latest developments in the world of electronics, the text continues to use Neil Storey's established and well-respected systems approach. It introduces the basic concepts first before progressing to a more advanced analysis, enabling you to contextualise what a system is designed to achieve before tackling the intricacies of designing or analysing its various components with confidence. This book is accompanied by a website which contains over 100 video tutorials to help explain ke...

  3. Data acquisition system for a deuteration chamber

    International Nuclear Information System (INIS)

    Monroy A, L.

    1994-01-01

    The work present is focusing auxiliary in the experiment the reaction of fusion in cold in the laboratory of Physical of Plasmas of Instituto Nacional de Investigaciones Nucleares. These systems of acquisition of data concrete to register in line surface of pressure and temperature in the gap of 5.6 x 10 -4 to 1 x 10 3 and -270 to 1300 Centigrade degrees with help of personal computer. The manner of purchase in chamber of Deuterium is per middle of thermocouple with the object of whereas any control of the temperature in different point in the some of manner the signal of in for the system is the thermocouple (milli volts), the conversion analogy a digital is mean of Cad of 12 bits rate double slope the out is mean the PPI to send the signal to P C of these manner the read of the thermocouples is translate graphic or digital in the screen of the P C. In the phase of pressure element sensor is measure type Pirani, the measure is of manner of temperature. (Author)

  4. Nuclear spectrometry data acquisition system based on LabVIEW

    International Nuclear Information System (INIS)

    Zhao Dan; Shen Li; Deng Lili; Zhou Sichun

    2006-01-01

    The whole process of designing nuclear spectrometry data acquisition system was particularized with LabVIEW and data acquisition board, based on virtual instrument technology. It can analyze the output of the radiation detector and give the height spectrum by the method of the continuous real-time data acquisition and the abstraction of pulse signal amplitude. The simple test shows that this system can meet the demand, and it can be easily expanded according to the situation. (authors)

  5. 3D - Acquisition systems - test in Chooz B nuclear plant

    International Nuclear Information System (INIS)

    Brillault, B.; Thibault, G.

    1992-06-01

    EDF needs 3D-acquisition systems to get the precise geometry of critical nuclear spaces in order to prepare computer simulations of operations in these areas. The simulations must lead to an increase of the efficiency of the operation. The acquisition of the 3-D geometry can be done using 3D-acquisition systems. To answer the needs of the Construction Division, four different systems are compared by the Research Division in Chooz B nuclear plant in order to determine the right solution for each 3D-acquisition problem

  6. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    Energy Technology Data Exchange (ETDEWEB)

    Wheat, Jr., Robert Mitchell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

  7. Programmable electronic safety systems

    International Nuclear Information System (INIS)

    Parry, R.R.

    1993-01-01

    Traditionally safety systems intended for protecting personnel from electrical and radiation hazards at particle accelerator laboratories have made extensive use of electromechanical relays. These systems have the advantage of high reliability and allow the designer to easily implement fail-safe circuits. Relay based systems are also typically simple to design, implement, and test. As systems, such as those presently under development at the Superconducting Super Collider Laboratory (SSCL), increase in size, and the number of monitored points escalates, relay based systems become cumbersome and inadequate. The move toward Programmable Electronic Safety Systems is becoming more widespread and accepted. In developing these systems there are numerous precautions the designer must be concerned with. Designing fail-safe electronic systems with predictable failure states is difficult at best. Redundancy and self-testing are prime examples of features that should be implemented to circumvent and/or detect failures. Programmable systems also require software which is yet another point of failure and a matter of great concern. Therefore the designer must be concerned with both hardware and software failures and build in the means to assure safe operation or shutdown during failures. This paper describes features that should be considered in developing safety systems and describes a system recently installed at the Accelerator Systems String Test (ASST) facility of the SSCL

  8. Programmable Electronic Safety Systems

    International Nuclear Information System (INIS)

    Parry, R.

    1993-05-01

    Traditionally safety systems intended for protecting personnel from electrical and radiation hazards at particle accelerator laboratories have made extensive use of electromechanical relays. These systems have the advantage of high reliability and allow the designer to easily implement failsafe circuits. Relay based systems are also typically simple to design, implement, and test. As systems, such as those presently under development at the Superconducting Super Collider Laboratory (SSCL), increase in size, and the number of monitored points escalates, relay based systems become cumbersome and inadequate. The move toward Programmable Electronic Safety Systems is becoming more widespread and accepted. In developing these systems there are numerous precautions the designer must be concerned with. Designing fail-safe electronic systems with predictable failure states is difficult at best. Redundancy and self-testing are prime examples of features that should be implemented to circumvent and/or detect failures. Programmable systems also require software which is yet another point of failure and a matter of great concern. Therefore the designer must be concerned with both hardware and software failures and build in the means to assure safe operation or shutdown during failures. This paper describes features that should be considered in developing safety systems and describes a system recently installed at the Accelerator Systems String Test (ASST) facility of the SSCL

  9. A compact multiparameter acquisition system for radon concentration studies

    Science.gov (United States)

    Pugliese; Baiano; Boiano; D'Onofrio; Roca; Sabbarese; Vollaro

    2000-07-01

    A compact device suitable to acquire and display, at the same time, radon concentrations in a given atmosphere, and the environmental parameters characterising the atmosphere, is presented and described. It consists of two main blocks: (i) a detection section including a set of sensors for measuring pressure, humidity and temperature, and a set of silicon surface barrier detectors mounted in electrostatic cells collecting the ionised radon daughters; (ii) a single NIM module featuring an eight channel 12 bit ADC and the linear electronics to shape the signals from the silicon detectors. The system is controlled by a computer via a RS232 port. The software, implemented in Visual Basic, allows to display the energy distribution of the pulses coming from the alpha detectors and to initialise and control all phases of the acquisition. The results of preliminary tests show the high reliability of the system.

  10. A compact multiparameter acquisition system for radon concentration studies

    International Nuclear Information System (INIS)

    Pugliese, M.; Baiano, G.; Boiano, A.; D'Onofrio, A.; Roca, V.; Sabbarese, C.; Vollaro, P.

    2000-01-01

    A compact device suitable to acquire and display, at the same time, radon concentrations in a given atmosphere, and the environmental parameters characterising the atmosphere, is presented and described. It consists of two main blocks: (i) a detection section including a set of sensors for measuring pressure, humidity and temperature, and a set of silicon surface barrier detectors mounted in electrostatic cells collecting the ionised radon daughters; (ii) a single NIM module featuring an eight channel 12 bit ADC and the linear electronics to shape the signals from the silicon detectors. The system is controlled by a computer via a RS232 port. The software, implemented in Visual Basic, allows to display the energy distribution of the pulses coming from the alpha detectors and to initialise and control all phases of the acquisition. The results of preliminary tests show the high reliability of the system

  11. Digital control and data acquisition system for the QUIET experiment

    International Nuclear Information System (INIS)

    Bogdan, Mircea; Kapner, Dan; Samtleben, Dorothea; Vanderlinde, Keith

    2007-01-01

    We present the Digital Control and Data Acquisition System (DCDAQ) for Phase I of the Q/U Imaging Experiment (QUIET), arrays of 91 W-band and 19 Q-band receivers, placed on 1.4 m telescopes, in Chajnantor, Chile to measure the polarization of the cosmic microwave background. QUIET uses custom-built electronics boards that control and monitor its polarimeters. Each of these boards is digitally addressable, so that the DCDAQ can set and monitor any of the 1600 biases needed to operate the 91 receivers. The DCDAQ consists of a controller and up to 13 custom-made 32-channel ADC cards. Local FPGAs allow real-time data processing for each channel. This immediate data reduction is necessary, as it is planned to scale this technology beyond Phase I. The DCDAQ system is implemented with this future in mind and can easily be scaled to operate 1000 receivers

  12. 76 FR 25566 - Defense Federal Acquisition Regulation Supplement (DFARS); Electronic Ordering Procedures (DFARS...

    Science.gov (United States)

    2011-05-05

    ... officials to specify e-mail as an ``electronic commerce method'' so long as it is authorized in the schedule... recognized electronic commerce method. The respondent recommended, in the alternative, that the Government... stated that electronic commerce is a term specifically identified in Federal Acquisition Regulation (FAR...

  13. Data-acquisition system for radon monitoring

    International Nuclear Information System (INIS)

    Franklin, J.C.; Zawadzki, R.J.; Meyer, T.O.; Hill, A.L.

    1976-01-01

    A data-acquisition system was designed by the Bureau of Mines to monitor five detectors with radon continuously flowing through each. These detectors could be monitored up to 12 times an hour, but were only monitored according to a preset time, thus allowing radon to be monitored continuously in a uranium mine. The counter can be set to monitor each detector for any period of time up to 16.5 minutes. This allows very low concentrations to be monitored longer to reduce statistical error. There would be no upper limit in radon concentration that could be monitored, but there would be a lower limit of 50 pCi/l. Each detector was calibrated by the Lucas flask method. Multiple samples were taken at two different concentrations, and the correction factor for each detector was determined by a least squares fit of the data. To verify the calibrations, a series of measurements at several concentrations were made against a constant source. The agreement at low radon concentrations (300 pCi/l) with the two-filter method was within 3 percent; thus, the total error would be this difference plus the two-filter error. At high concentrations, the coefficient of variation ranged between 2.1 and 9.8 percent for the five different detector units

  14. Integrated delivery systems: mergers and acquisitions.

    Science.gov (United States)

    Pinkerton, S

    1999-01-01

    Mergers and acquisitions are usually the way an IDS is built. The CNO and/or CNOs/DONs have an integral role in the resolution of the M/A process. During this time of significant change, during which there may even be chaos, the CNOs work to maintain stability so there is as little impact as possible on patient outcomes, a core responsibility of the CNOs. The CNOs should focus on identifying and working with the highly skilled individuals in the organization to get to the recovery stage of the M/A process, at which time a high-performing organization is achieved. To build this new organization or IDS, the old organizations of the M/A must be changed (Moss Kanter, 1994). The successful CNOs will manage the trade-offs and will become experts in collaboration. The CNO's goals are to maximize the quality of patient care, the professional satisfaction of the nurse, and the goals of achieving cost effectiveness for the system (Clifford, 1998), and keeping this focus through the M/A process will yield success.

  15. Electron-electron interactions in disordered systems

    CERN Document Server

    Efros, AL

    1985-01-01

    ``Electron-Electron Interactions in Disordered Systems'' deals with the interplay of disorder and the Coulomb interaction. Prominent experts give state-of-the-art reviews of the theoretical and experimental work in this field and make it clear that the interplay of the two effects is essential, especially in low-dimensional systems.

  16. Electron beam processing system

    International Nuclear Information System (INIS)

    Kashiwagi, Masayuki

    2004-01-01

    Electron beam Processing Systems (EPS) are used as useful and powerful tools in many industrial application fields such as the production of cross-linked wire, rubber tire, heat shrinkable film and tubing, curing, degradation of polymers, sterilization and environmental application. In this paper, the feature and application fields, the selection of machine ratings and safety measures of EPS will be described. (author)

  17. Study of customer acquisition support system for mobile operators

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The mobile operators are struggling for improving the market share and the revenues.One important method is to acquire the potential customers from the competitors.This article presents a whole acquisition process and an integrated framework for customer acquisition support system (CASS).The core of the system is the customer acquisition identification models which are built based on data mining technologies.The CASS can automate the acquisition process and decrease the cost and implement precise marketing strategy for mobile operators.

  18. 'RADAR': Euratom's standard unattended data acquisition system

    International Nuclear Information System (INIS)

    Schwalbach, P.; Holzleitner, L.; Jung, S.; Chare, P.; Smejkal, A.; Swinhoe, M.; Kloeckner, W.

    2001-01-01

    Full text: The physical verification of nuclear material is an essential part of Euratom's inspection activities. Industrial plants handling large amounts of bulk material typically require large numbers of measurements. Modem plants, particularly plutonium-handling facilities, are normally automated and make it difficult for the inspector to access the material. Adapting to the plant requirements with respect to safety and security as well as economics (throughput), safeguards instrumentation is today often integrated into the plant. In order to optimize scarce inspection resources, the required measurements as well as the data analysis have to be done automatically as far as feasible. For automatic measurements Euratom has developed a new unattended data acquisition system, called RADAR (Remote Acquisition of Data and Review), which has been deployed to more than a dozen installations, handling more than 100 sensors (neutron and gamma radiations detectors, balances, seals, identity readers, switches, etc.). RADAR is the standard choice for new systems but is also replacing older automatic data systems slowly as they become outdated. RADAR and most of the associated analysis tools are the result of an in-house development, with the support of external software contractors where appropriate. Experience with turn-key systems led, in 1997, to the conclusion that in-house development would be a more effective use of resources than to buy third party products. RADAR has several layers, which will be discussed in detail in the presentation. The inner core of the package consists of services running under Windows NT. This core has watchdog and logging functions, contains a scheduler and takes care of replicating files across a network. Message and file exchange is based on TCP/IP. The replicator service contains compression and encryption facilities, the encryption is based on POP. With the help of routers, e.g. from CISCO, network connections to remote locations can be

  19. Report on a field-portable VME-based distributed data acquisition system

    International Nuclear Information System (INIS)

    Drigert, M.W.; Cole, J.D.; Reber, E.L.; Young, J.M.

    1996-01-01

    A development effort was started two years ago to develop a portable data acquisition system which could be used for performing arms control verification and environmental monitoring measurements with complex multi-detector systems in the field. A field portable data acquisition system has been developed around a VMEbus based micro-processor and standard TCP/IP network protocols. The hardware consists of a compact VME crate and a single CAMAC crate containing the signal processing electronics. The component processes of the data acquisition system transfer control and event data over a set of TCP/IP socket connections. The use of network sockets for the interprocess communications allows the data acquisition system to be operated transparently on one workstation or on a number of workstations distributed around a local network

  20. The image acquisition system design of floor grinder

    Science.gov (United States)

    Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin

    2018-01-01

    Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.

  1. Image acquisition system for traffic monitoring applications

    Science.gov (United States)

    Auty, Glen; Corke, Peter I.; Dunn, Paul; Jensen, Murray; Macintyre, Ian B.; Mills, Dennis C.; Nguyen, Hao; Simons, Ben

    1995-03-01

    An imaging system for monitoring traffic on multilane highways is discussed. The system, named Safe-T-Cam, is capable of operating 24 hours per day in all but extreme weather conditions and can capture still images of vehicles traveling up to 160 km/hr. Systems operating at different remote locations are networked to allow transmission of images and data to a control center. A remote site facility comprises a vehicle detection and classification module (VCDM), an image acquisition module (IAM) and a license plate recognition module (LPRM). The remote site is connected to the central site by an ISDN communications network. The remote site system is discussed in this paper. The VCDM consists of a video camera, a specialized exposure control unit to maintain consistent image characteristics, and a 'real-time' image processing system that processes 50 images per second. The VCDM can detect and classify vehicles (e.g. cars from trucks). The vehicle class is used to determine what data should be recorded. The VCDM uses a vehicle tracking technique to allow optimum triggering of the high resolution camera of the IAM. The IAM camera combines the features necessary to operate consistently in the harsh environment encountered when imaging a vehicle 'head-on' in both day and night conditions. The image clarity obtained is ideally suited for automatic location and recognition of the vehicle license plate. This paper discusses the camera geometry, sensor characteristics and the image processing methods which permit consistent vehicle segmentation from a cluttered background allowing object oriented pattern recognition to be used for vehicle classification. The image capture of high resolution images and the image characteristics required for the LPRMs automatic reading of vehicle license plates, is also discussed. The results of field tests presented demonstrate that the vision based Safe-T-Cam system, currently installed on open highways, is capable of producing automatic

  2. A DSP controlled data acquisition system for CELSIUS

    International Nuclear Information System (INIS)

    Bengtsson, M.; Lofnes, T.; Ziemann, V.

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities

  3. A DSP controlled data acquisition system for CELSIUS

    CERN Document Server

    Bengtsson, M; Ziemann, Volker

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities.

  4. Progress on the data acquisition system at NSCL

    International Nuclear Information System (INIS)

    Fox, R.; Au, R.; Glynn, T.; Pollack, B.; Vander Mulen, A.

    1985-01-01

    We report on the progress made in data acquisition software development. Specifically, a unique generalized data routing scheme has been developed which allows user online analysis programs to be safely integrated into the acquisition system without endangering data sent to event recording devices. We describe the structure of the system. Performance is discussed and throughput calculated from it. User experience with the system is also discussed. We show how this routing system may easily be adapted to loosely coupled multiprocessor systems

  5. Operation and maintenance manual for data acquisition system of MIDAS

    International Nuclear Information System (INIS)

    Lee, D. Y.; Park, W. M.; Kim, J. T.; Euh, D. J.

    2001-09-01

    This report describes an operation and maintenance manual of the data acquisition system and the data processing system for the DVI performance evaluation facility, MIDAS. The data acquisition system is implemented with VXI based system of Kinetic Systems TM , and the data processing PC. This report presents the configuration method and operation procedure for the operator. The modification procedure and method for functional extension and performance modification are also included for the future demand

  6. Real-Time Wireless Data Acquisition System

    Science.gov (United States)

    Valencia, Emilio J.; Perotti, Jose; Lucena, Angel; Mata, Carlos

    2007-01-01

    Current and future aerospace requirements demand the creation of a new breed of sensing devices, with emphasis on reduced weight, power consumption, and physical size. This new generation of sensors must possess a high degree of intelligence to provide critical data efficiently and in real-time. Intelligence will include self-calibration, self-health assessment, and pre-processing of raw data at the sensor level. Most of these features are already incorporated in the Wireless Sensors Network (SensorNet(TradeMark)), developed by the Instrumentation Group at Kennedy Space Center (KSC). A system based on the SensorNet(TradeMark) architecture consists of data collection point(s) called Central Stations (CS) and intelligent sensors called Remote Stations (RS) where one or more CSs can be accommodated depending on the specific application. The CS's major function is to establish communications with the Remote Stations and to poll each RS for data and health information. The CS also collects, stores and distributes these data to the appropriate systems requiring the information. The system has the ability to perform point-to-point, multi-point and relay mode communications with an autonomous self-diagnosis of each communications link. Upon detection of a communication failure, the system automatically reconfigures to establish new communication paths. These communication paths are automatically and autonomously selected as the best paths by the system based on the existing operating environment. The data acquisition system currently under development at KSC consists of the SensorNet(TradeMark) wireless sensors as the remote stations and the central station called the Radio Frequency Health Node (RFHN). The RFF1N is the central station which remotely communicates with the SensorNet(TradeMark) sensors to control them and to receive data. The system's salient feature is the ability to provide deterministic sensor data with accurate time stamps for both time critical and non

  7. Design of the data acquisition and analysis system for RFX

    International Nuclear Information System (INIS)

    Flor, G.

    1986-01-01

    This paper describes the conceptual design of the data acquisition and analysis system for the RFX experiment. In order to adequately describe an intrinsically dynamic experiment, the concept of an experiment's model is introduced. The model is generated by means of a suitable experiment description language; the diagnostic system is represented as a tree structure and is described by defining all the data and devices involved in the data acquisition system. The resulting data structures drive the data acquisition process and can be used, with minor modifications, as data descriptions in the archiving system. The need of a generalized I/O system is envisaged and a way to implement it is outlined

  8. 78 FR 28756 - Defense Federal Acquisition Regulation Supplement: System for Award Management Name Changes...

    Science.gov (United States)

    2013-05-16

    ... Management Name Changes, Phase 1 Implementation (DFARS Case 2012- D053) AGENCY: Defense Acquisition... Excluded Parties Listing System (EPLS) databases into the System for Award Management (SAM) database. DATES... enacted in an effort to improve the management and promotion of electronic Government services and...

  9. Information management system breadboard data acquisition and control system.

    Science.gov (United States)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  10. Select PC/windows flat to develop data acquisition system

    International Nuclear Information System (INIS)

    Zhang Jin

    1993-01-01

    Through needing analysis, and also, considering user's ability of payment, the characteristic of China computer market, the computer developing tending, and the system's compatibility and up grade capability, PC/Windows flat are selected to develop a data acquisition system

  11. Software aspects of designing an online data acquisition system

    International Nuclear Information System (INIS)

    Bandyopadhyay, A.

    1989-01-01

    The design aspect of a data acquisition system software for experimental nuclear physics applications is discussed. The features of a good data acquisition system and the techniques which are used to meet the requirements are also discussed. The suitability of different programming languages for different applications have been outlined. The operating system requirements and the difficulties encountered by the programmer for non-ideal operating system environment is also highlighted. (author)

  12. Improvement of digital data acquisition system in reflood test rig

    International Nuclear Information System (INIS)

    Sudoh, Takashi; Murao, Yoshio; Niitsuma, Yasushi

    1979-03-01

    The original master digital data acquisition system was designed to collect 30 channels of analog data rapidly and convert them into digital form for recording on a magnetic tape. Due to the increases in the number of channels and the ranges of measurement, an additional acquisition device was needed for the original system. This report descrives the design of the additional data acquisition device and the results of performance tests. The operational manual is attached as an appendix. It was confirmed that the new system satisfied the requirements of system. (author)

  13. Minicomputer data acquisition system for nuclear physics applications

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, R [Princeton Univ., NJ (USA). Joseph Henry Labs.

    1978-09-15

    The data acquisition system for the Princeton Cyclotron facility based on a Data General Eclipse computer is described. The program ACQUIRE is a highly flexible acquisition code able to support diverse experimental requirements and yet capable of sorting a repetitious pulser in a single ADC at up to 40 kHz without loss.

  14. The Data Acquisition System for a Kinetic Inductance Detector

    International Nuclear Information System (INIS)

    Branchini, P; Budano, A; Capasso, L; Marchetti, D

    2015-01-01

    The Data Acquisition System (DAQ) and the Front-End electronics for an array of Kinetic Inductance Detectors (KIDs) are described. KIDs are superconductive detectors, in which electrons are organized in Cooper pairs. Any incident radiation could break a pair generating a couple of quasi-particles that increase the inductance of the detector. The DAQ system we developed is a hardware/software co-design, based on state machines and on a microprocessor embedded into an FPGA. A commercial DAC/ADC board is used to interface the FPGA to the array of KIDs. The DAQ system generates a Stimulus signal suitable for an array of up to 128 KIDs. Such signal is up-mixed with a 3 GHz carrier wave and it then excites the KIDs array. The read-out signal from the detector is down-mixed with respect to the 3 GHz sine wave and recovered Stimulus is read back by the ADC device. The microprocessor stores read out data via a PCI express bus (PCIe) into an external disk. It also computes the Fast Fourier Transform of the acquired read out signal: this allows extrapolating which KID interacted and the energy of the impinging radiation. Simulations and tests have been performed successfully and experimental results are presented. (paper)

  15. Dumand-array data-acquisition system

    International Nuclear Information System (INIS)

    Brenner, A.E.; Theriot, D.; Dau, W.D.; Geelhood, B.D.; Harris, F.; Learned, J.G.; Stenger, V.; March, R.; Roos, C.; Shumard, E.

    1982-04-01

    An overall data acquisition approach for DUMAND is described. The scheme assumes one array to shore optical fiber transmission line for each string of the array. The basic event sampling period is approx. 13 μsec. All potentially interesting data is transmitted to shore where the major processing is performed

  16. Electronics for embedded systems

    CERN Document Server

    Bindal, Ahmet

    2017-01-01

    This book provides semester-length coverage of electronics for embedded systems, covering most common analog and digital circuit-related issues encountered while designing embedded system hardware. It is written for students and young professionals who have basic circuit theory background and want to learn more about passive circuits, diode and bipolar transistor circuits, the state-of-the-art CMOS logic family and its interface with older logic families such as TTL, sensors and sensor physics, operational amplifier circuits to condition sensor signals, data converters and various circuits used in electro-mechanical device control in embedded systems. The book also provides numerous hardware design examples by integrating the topics learned in earlier chapters. The last chapter extensively reviews the combinational and sequential logic design principles to be able to design the digital part of embedded system hardware.

  17. UNIBUS processor interface for a FASTBUS data acquisition system

    International Nuclear Information System (INIS)

    Larwill, M.; Lagerlund, T.D.; Barsotti, E.; Taff, L.M.; Franzen, J.

    1981-01-01

    Current work on a FASTBUS data acquisition system at Fermilab is described. The system will consist of three pieces of FASTBUS hardware: a UNIBUS processor interface (UPI), a dual-ported bulk memory, and a FASTBUS ''event builder'' (i.e., data acquisition processor). Primary efforts have been on specifying and constructing a UPI. The present specification includes capability for all basic FASTBUS operations, including list processing of consecutive FASTBUS operations. Some possible FASTBUS data acquisition system architectures employing the UPI are discussed along with some detailed specifications of the UPI itself

  18. A nuclear data acquisition system flow control model

    International Nuclear Information System (INIS)

    Hack, S.N.

    1988-01-01

    A general Petri Net representation of a nuclear data acquisition system model is presented. This model provides for the unique requirements of a nuclear data acquisition system including the capabilities of concurrently acquiring asynchronous and synchronous data, of providing multiple priority levels of flow control arbitration, and of permitting multiple input sources to reside at the same priority without the problem of channel lockout caused by a high rate data source. Finally, a previously implemented gamma camera/physiological signal data acquisition system is described using the models presented

  19. Incorporating Ethical Consumption into Electronic Device Acquisition: A Proposal

    Science.gov (United States)

    Poggiali, Jennifer

    2016-01-01

    This essay proposes that librarians practice ethical consumption when purchasing electronic devices. Though librarians have long been engaged with environmentalism and social justice, few have suggested that such issues as e-waste and sweatshop labor should impact our decisions to acquire e-readers, tablets, and other electronics. This article…

  20. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  1. Data acquisition system for fusion diagnostics on the ARGUS laser

    International Nuclear Information System (INIS)

    Greenwood, J.R.; Campbell, D.E.; Frerking, C.E.

    1976-09-01

    An extensive data acquisition and analysis system has been implemented for experiments on the ARGUS laser. The system is based upon a PDP-11/40 minicomputer and CAMAC interfaces. Highspeed transient digitizers, calorimeter digitizing modules and time integrated data are interfaced through CAMAC over a fiber optic serial highway. The system allows for dynamic definition of the experimental environment by an operator, automatic data acquisition during a shot. Two interactive graphics terminals allow experimenters real-time access to target shot data

  2. The data acquisition system for the JADE detector

    International Nuclear Information System (INIS)

    Cords, D.; Dittmann, P.; Eichler, R.; Mills, H.E.

    1985-07-01

    An outline of the data acquisition system for the JADE experiment at PETRA, DESY is presented. After describing the hardware configuration, we describe our guiding ideas for the design of the data acquisition system, which is followed by accounts of the implementation of real time software, the data flow, the monitoring and detector control as well as the online event analysis and filtering. Finally we summarise our experience with the system. (orig.)

  3. The trigger and data acquisition system of the SAPHIR detector

    International Nuclear Information System (INIS)

    Honscheid, K.

    1988-10-01

    At present SAPHIR, a new experimental facility for medium energy physics is under construction at the Bonn electron accelerator ELSA (energy ≤ 3.5 GeV, duty cycle ≅ 100%). SAPHIR combines a large solid angle coverage with a tagging system and is therefore suited to investigate reactions with multi-particle final states. Structure and function of the multi-stage trigger system, which is used to select such processes, are described in this paper. With this system the trigger decision can be based on the number of charged particles as well as on the number of neutral particle detected. Several VMEbus modules have been developed, using memory look-up tables to make fast trigger decisions possible. In order to determine the number of neutral particles from the cluster distribution in the electromagnetic calorimeter some ideas of cellular had to be added. The system has a modular structure, so it can easily be extended. In the second part of this thesis the SAPHIR data acquisition system is discussed. It consists of a multiprocessor system with the VIP microcomputer as central element. The VIP is a VMEbus modul optimized for a multiprocessor environment. Its description as well as that of the other VMEbus boards developed for the SAPHIR online system can be found in this paper. As a basis for software development the operating system SOS is supplied. With SOS it is possible to write programs independent of the actual hardware configuration and so the complicated multiprocessor environment is hidden. To the user the system looks like a simple multi-tasking system. SOS is not restricted to the VIPs but can also be installed on computers of the VAX family, so that efficient mixed configurations are possible. The SAPHIR online system, based on the VIP microcomputer and the SOS operating system, is presented in the last part of this paper. This includes the read-out system, the monitoring of the different components etc. (orig./HSI) [de

  4. Embedded systems design for high-speed data acquisition and control

    CERN Document Server

    Di Paolo Emilio, Maurizio

    2015-01-01

    This book serves as a practical guide for practicing engineers who need to design embedded systems for high-speed data acquisition and control systems. A minimum amount of theory is presented, along with a review of analog and digital electronics, followed by detailed explanations of essential topics in hardware design and software development. The discussion of hardware focuses on microcontroller design (ARM microcontrollers and FPGAs), techniques of embedded design, high speed data acquisition (DAQ) and control systems. Coverage of software development includes main programming techniques, culminating in the study of real-time operating systems. All concepts are introduced in a manner to be highly-accessible to practicing engineers and lead to the practical implementation of an embedded board that can be used in various industrial fields as a control system and high speed data acquisition system.   • Describes fundamentals of embedded systems design in an accessible manner; • Takes a problem-solving ...

  5. Design and Implementation of the Dynamic Data Acquisition and Historical Data Query System for BEPCII Control System

    International Nuclear Information System (INIS)

    Ma Mei; Huang Song; Zhao Jijiu; Zhao Zhuo; Huang Xianghao; Wang Jincan; Wang Chunhong; Fan Ruohong

    2009-01-01

    The BEPCII is the project of upgrading Beijing Electron Positron Collider, and it's one of the National fundamental research center. Based on the dynamic data query system of the BEPCII control system which has already been put into operation, it provides a more comprehensive presentation of the dynamic data acquisition, historical data query system, including system architecture, database design, development schema and technology, the system environment and system function, and illustrated some results of the system operating. (authors)

  6. Bus-based architectures in the H1 data acquisition system

    International Nuclear Information System (INIS)

    Haynes, W.J.

    1992-08-01

    The recently commissioned Hadron-Electron Ring Anage (HERA) electron-proton collider at DESY, Deutsches Elektronen Synchrotron has presented a challenging environment in coping with huge volumes of data in real-time. With bunch-crossing intervals of 96 nanoseconds, the H1 experiment can generate nearly 3 Megabytes of raw digital information from several hundred thousand electronic channels. The open VMEbus standard is exploited to provide the necessary modularity and system flexibility for embedding fast readout electronics in a multiprocessor design array. The architectural concepts of the data acquisition structure are discussed together with many of the experiences gained in implementing a large multi-crate system. (author)

  7. The Defense Systems Acquisition and Review Council

    Science.gov (United States)

    1976-09-15

    34 or budget subimittal and explained. f. w.hen an OSD-generated PPES document, such as tK2 Issue Paper or PPJ, offers an alternative to the 9CP/ )SARC...cost objectives, and operating constraints. A mission need may result from a deficiency in existing agency capabilities or the decision to establish new...missions, capabilities; deficiencies , and needs and objectives related to acquisition programs, in consonance with Section 601(i) of the Congressional

  8. PCI-VME bridge device driver design of a high-performance data acquisition and control system on LINUX

    International Nuclear Information System (INIS)

    Sun Yan; Ye Mei; Zhang Nan; Zhao Jingwei

    2000-01-01

    Data Acquisition and Control is an important part of Nuclear Electronic and Nuclear Detection application in HEP. The key methods are introduced for designing LINUX Device Driver of PCI-VME Bridge Device based on the realized Data Acquisition and Control System

  9. PCI-VME bridge device driver design of a high-performance data acquisition and control system on LINUX

    International Nuclear Information System (INIS)

    Sun Yan; Ye Mei; Zhang Nan; Zhao Jingwei

    2001-01-01

    Data acquisition and control is an important part of nuclear electronic and nuclear detection application in HEP. The key method has been introduced for designing LINUX device driver of PCI-VME bridge device based on realized by authors' data acquisition and control system

  10. Recent developments of the RFX control and data acquisition system

    International Nuclear Information System (INIS)

    Barana, O.; Luchetta, A.; Manduchi, G.; Taliercio, C.

    2004-01-01

    Although the new RFX machine is still under modification, most power supply systems have been used since early 2003 for testing an ITER high-power by-pass switch. This has given us the opportunity to verify the effectiveness of several choices we made in the development of the new data acquisition and control system of RFX. The system has been renewed both in its control and data acquisition components. For control, the new system employs Simatic S7 PLCs and a commercial Supervisory Control and Data Acquisition (SCADA) tool. Many improvements have been made to the MDSplus-based data acquisition system. The whole system has been ported from OpenVMS to Linux, using a server for data storage and CAMAC data acquisition, and a set of CompactPCI crates, each hosting a Linux PC board. Device-specific code is now entirely implemented in TDI, the scripting language of MDSplus. Our experience in the new system has been positive, especially for the data acquisition system

  11. Data acquisition system in TPE-1RM15

    International Nuclear Information System (INIS)

    Yagi, Yasuyuki; Yahagi, Eiichi; Hirano, Yoichi; Shimada, Toshio; Hirota, Isao; Maejima, Yoshiki

    1991-01-01

    The data acquisition system for TPE-1RM15 reversed field pinch machine had been developed and has recently been completed. Thd data to be acquired consist of many channels of time series data which come from plasma diagnostics. The newly developed data acquisition system uses CAMAC (Computer Automated Measurement And Control) system as a front end data acquisition system and micro-VAX II for control, file management and analyses. Special computer programs, DAQR/D, have been developed for data acquisition routine. Experimental setting and process controlling items are managed by a parameter database in a shared common region and every task can easily refer to it. The acquired data are stored into a mass storage system (total of 1.3GBytes plus a magnetic tape system) including an optical disk system, which can save storage space and allow quick reference. At present, the CAMAC system has 88 (1MHz sampling) and 64(5kHz sampling) channels corresponding to 1.6 MBytes per shot. The data acquisition system can finish one routine within 5 minutes with 1.6MBytes data depending on the amount of graphic outputs. Hardwares and softwares of the system are specified so that the system can be easily expanded. The computer is connected to the AIST Ethernet and the system can be remotely accessed and the acquired data can be transferred to the mainframes on the network. Details about specifications and performance of the system are given in this report. (author)

  12. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  13. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  14. Equipment acquisition plans for the SSCL magnet excitation power system

    International Nuclear Information System (INIS)

    Winje, R.

    1993-05-01

    This report gives a brief description of the major electrical technical equipment used in the Superconducting Super Collider accelerators systems and the present laboratory plans for the acquisition of the equipment

  15. Understanding Information Systems Integration Deficiencies in Mergers and Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Kettinger, William J.

    2017-01-01

    Information systems (IS) integration is a critical challenge for value-creating mergers and acquisitions. Appropriate design and implementation of IS integration is typically a precondition for enabling a majority of the anticipated business benefits of a combined organization. Often...

  16. Aircraft Nodal Data Acquisition System (ANDAS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Development of an Aircraft Nodal Data Acquisition System (ANDAS) based upon the short haul Zigbee networking standard is proposed. It employs a very thin (135 um)...

  17. Online event filtering in the JADE data acquisition system

    International Nuclear Information System (INIS)

    Mills, H.E.

    1986-01-01

    The data acquisition system developed for the JADE experiment at PETRA, DESY includes the facility to use software to filter out background events. The design, implementation, testing and experience gained are discussed. (orig.)

  18. Extremelly High Bandwidth Rad Hard Data Acquisition System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Analog-to-digital converters (ADCs) are the key components for digitizing high-speed analog data in modern data acquisition systems, which is a critical part of...

  19. Multiple-user data acquisition and analysis system

    International Nuclear Information System (INIS)

    Manzella, V.; Chrien, R.E.; Gill, R.L.; Liou, H.I.; Stelts, M.L.

    1981-01-01

    The nuclear physics program at the Brookhaven National Laboratory High Flux Beam Reactor (HFBR) employs a pair of PDP-11 computers for the dual functions of data acquisition and analysis. The data acquisition is accomplished through CAMAC and features a microprogrammed branch driver to accommodate various experimental inputs. The acquisition computer performs the functions of multi-channel analyzers, multiscaling and time-sequenced multichannel analyzers and gamma-ray coincidence analyzers. The data analysis computer is available for rapid processing of data tapes written by the acquisition computer. The ability to accommodate many users is facilitated by separating the data acquisition and analysis functions, and allowing each user to tailor the analysis to the specific requirements of his own experiment. The system is to be upgraded soon by the introduction of a dual port disk to allow a data base to be available to each computer

  20. The data acquisition system for the ANTARES neutrino telescope

    International Nuclear Information System (INIS)

    Aguilar, J.A.; Albert, A.; Ameli, F.

    2007-01-01

    The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described

  1. The data acquisition system for the ANTARES neutrino telescope

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, J.A. [IFIC, Instituto de Fisica Corpuscular, Edificios Investigacion de Paterna, CSIC, Universitat de Valencia, Apdo. de Correos 22085, 46071 Valencia (Spain); Albert, A. [GRPHE - Groupe de Recherche en Physique des Hautes Energies, Universite de Haute Alsace, 61 Rue Albert Camus, 68093 Mulhouse Cedex (France); Ameli, F. [Dipartimento di Fisica dell' Universita ' La Sapienza' e Sezione INFN, P.le Aldo Moro 2, 00185 Rome (Italy)] (and others)

    2007-01-01

    The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described.

  2. Construction of a FASTBUS data-acquisition system for the ELAN experiment

    International Nuclear Information System (INIS)

    Noel, A.

    1992-06-01

    To use the FASTBUS data acquisition system for the experiment ELAN at the electron stretcher accelerator ELSA a new software tool has been developed. This tool manages to readout parallel CAMAC with a VME front-end-processor and FASTBUS with the special FASTBUS processor segment AEB. Both processors are connected by a 32 bit high speed VSB data bus. (orig.) [de

  3. Submicronic Particle Measurement Instrumentation Test Bench Data Acquisition and Control System

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J. M.; Sanz, D.; Gomez, F. J.; Molinero, A.; Navarrete, J. J.

    1999-01-01

    This document describes the SAD-100 system characteristics. The unit makes the instrumentation test bench data acquisition and control, SAD-100 was designed and developed by Electronic and Automation Area (CIEMAT) and Aerosol Technology in Energy Generation Project (CIEMAT). (Author) 2 refs

  4. A PC-Linux-based data acquisition system for the STAR TOFp detector

    International Nuclear Information System (INIS)

    Liu Zhixu; Liu Feng; Zhang Bingyun

    2003-01-01

    Commodity hardware running the open source operating system Linux is playing various important roles in the field of high energy physics. This paper describes the PC-Linux-based Data Acquisition System of STAR TOFp detector. It is based on the conventional solutions with front-end electronics made of NIM and CAMAC modules controlled by a PC running Linux. The system had been commissioned into the STAR DAQ system, and worked successfully in the second year of STAR physics runs

  5. Operational experience with the CMS Data Acquisition System

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The data-acquisition (DAQ) system of the CMS experiment at the LHC performs the read-out and assembly of events accepted by the first level hardware trigger. Assembled events are made available to the high-level trigger (HLT), which selects interesting events for offline storage and analysis. The system is designed to handle a maximum input rate of 100 kHz and an aggregated throughput of 100 GB/s originating from approximately 500 sources and 10^8 electronic channels. An overview of the architecture and design of the hardware and software of the DAQ system is given. We report on the performance and operational experience of the DAQ and its Run Control System in the first two years of collider run of the LHC, both in proton-proton and Pb-Pb collisions. We present an analysis of the current performance, its limitations, and the most common failure modes and discuss the ongoing evolution of the HLT capability needed to match the luminosity ramp-up of the LHC.

  6. THE ATLAS DATA ACQUISITION SYSTEM IN LHC RUN 2

    CERN Document Server

    Pozo Astigarraga, Mikel Eukeni; The ATLAS collaboration

    2017-01-01

    The LHC has been providing proton-proton collisions with record intensity and energy since the start of Run 2 in 2015. In the ATLAS experiment the Data Acquisition is responsible for the transport and storage of the more complex event data at higher rates that the new collision environment implies. Data from events selected by the first level hardware trigger are subject to further filtration from software running on a commodity server farm. During this time the data are transferred from detector electronics across 1900 optical links to custom buffer hardware hosted across 100 commodity server PCs, and then across the system for processing by high bandwidth network at an average throughput of 30 GB/s. Accepted events are transported to a data logging system for final packaging and transfer to permanent storage, with an average output rate of 1.5 GB/s. The whole system is actively monitored to maximise efficiency and minimise downtime. Due to the scale of the system and the challenging collision environment th...

  7. Control and Data Acquisition System for the Spanish Beamline (BM25) at the ESRF

    International Nuclear Information System (INIS)

    Pereira Gonzalez, A.; Olalla Garcia, C.; Sanchez Sanz, J.; Castro, G. R.

    2005-01-01

    A new control and data acquisition system has been developed for BM25 Spanish Line at the ESRF. The system is based in VMEbus, Motorola PreP architecture and Linux Operating System and it's linked to a local ETHERNET network which provides the way of communicate with the servers (PC workstations). In these computers, the data are available for general usage in order to analyze them. The data acquisition consists of many channels connected to the VME crates mainly, independent between them, and fully programmable by drivers, CLUI's and GUI's interfaces, and a set of independent systems (embedded ones, PLCs, others) controlling the security aspects. This report is described in terms of their architecture, their electronic system to the process hard ware and the functionality and the application development facilities they provide using the software and the data acquisition. (Author) 18 refs

  8. An introduction to LAMPF data acquisition system introduce

    International Nuclear Information System (INIS)

    Fu Saihong

    1993-01-01

    LAMPF Data Acquisition Systems are divided into general DAQ system and advanced MEGA DAQ system. The construct and future plan of general system are described. The second stage trigger has been implemented at LAMPF using a commercially available workstation and VME interface. The implementation is described and measurements of data transfer speeds are presented

  9. Data acquisition system for linear position sensitive detector based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, A.; Prafulla, S.; Srivastava, V.D.; Mukhopadhyaya, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2003-03-01

    This data acquisition system is developed to serve the requirements of various linear 1PSD based neutron diffractometers. A neutron diffractometer uses a neutron beam as a probe to study the crystallographic properties of materials. Presently two multi-PSD and two single-PSD diffractometers are commissioned and a few more are being installed in Dhruva. This data acquisition system is installed at each of these - diffractometers. Different requirements of individual diffractometers were studied and reconciled to design a single data acquisition system, which can be easily configured or customized for individual setups. The charge division in a linear PSD is converted to a position output with the help of an RDC (Ratio ADC). The ftont-end electronics, which consist of preamplifiers and shaping amplifiers, provide an interface between a PSD and an RDC. A PC add-on card is designed around a Transputer. It can interface 16 RDCs, a few motor controls and on/off controls. Data acquisition and other controls are implemented in the Transputer program. A front-end Windows98 application merges the raw data of different RDCs to obtain the equiangular data. Through software the data acquisition system can be configured for diffetent diffractometers. Commercially available hardware is also integrated as,a part of the data acquisition system in some of the setups. The data acquisition system is working reliably as a part of two single PSD and two multi-PSD diffractometers. It can handle data rates upto 15 K/Sec without any loss of counts. It has played a significant role in providing improved throughput and utilization ofvarious diffractometers. The'data acquisition system and its different applications are presented in this report. (author)

  10. Versatile data acquisition system and the ISOL facility TRISTAN

    International Nuclear Information System (INIS)

    Gill, R.L.; Stelts, M.L.; Chrien, R.E.; Manzella, V.; Liou, H.I.; Shostak, S.

    1980-01-01

    The on-line mass separator, TRISTAN, is located at Brookhaven's High Flux Beam Reactor. A Nielsen-type ion source, which can contain up to 8g. of 235 U in an external beam with a flux of approx. 2 x 10 9 n/cm 2 /sec is used to generate short-lived fission products. A Users Group has been formed to coordinate research between University groups and BNL. Developments planned for TRISTAN include FEBIAD, surface ionization and negative-surface ionization-type ion sources, and a He-jet system as well as construction of new experimental facilities. An off-line separator, ISTU, is available for the development program. A versatile, modular data acquisition system to service experiments on TRISTAN and other nuclear research facilities at the HFBR using Camac interfacing is described. Standard, commercially-available electronic instruments and computer programs, such as FORTRAN and system routines, are used throughout. Simple interfaces have been built to adapt non-Camac equipment to Camac input registers

  11. The ATLAS Data Acquisition System in LHC Run 2

    CERN Document Server

    Pozo Astigarraga, Mikel Eukeni; The ATLAS collaboration

    2017-01-01

    The LHC has been providing proton-proton collisions with record intensity and energy since the start of Run 2 in 2015. In the ATLAS experiment the Data Acquisition is responsible for the transport and storage of the more complex event data at higher rates that the new collision environment implies. Data from events selected by the first level hardware trigger are subject to further filtration from software running on a commodity load balanced processing farm of some 2000 servers. During this time the data transferred from detector electronics across 1900 optical links to custom buffer hardware hosted across 100 commodity server PCs, and transferred across the system for processing by high bandwidth network at an average throughput of 30 GB/s. Accepted events are then transported to a data logging system for final packaging and transfer to permanent storage, with a final average output bandwidth of 1.5 GB/s. The whole system is actively monitored to maximise efficiency and minimise downtime. Due to the scale o...

  12. ARM Processor Based Embedded System for Remote Data Acquisition

    OpenAIRE

    Raj Kumar Tiwari; Santosh Kumar Agrahari

    2014-01-01

    The embedded systems are widely used for the data acquisition. The data acquired may be used for monitoring various activity of the system or it can be used to control the parts of the system. Accessing various signals with remote location has greater advantage for multisite operation or unmanned systems. The remote data acquisition used in this paper is based on ARM processor. The Cortex M3 processor used in this system has in-built Ethernet controller which facilitate to acquire the remote ...

  13. Electronic Nicotine Delivery Systems.

    Science.gov (United States)

    Walley, Susan C; Jenssen, Brian P

    2015-11-01

    Electronic nicotine delivery systems (ENDS) are rapidly growing in popularity among youth. ENDS are handheld devices that produce an aerosolized mixture from a solution typically containing concentrated nicotine, flavoring chemicals, and propylene glycol to be inhaled by the user. ENDS are marketed under a variety of names, most commonly electronic cigarettes and e-cigarettes. In 2014, more youth reported using ENDS than any other tobacco product. ENDS pose health risks to both users and nonusers. Nicotine, the major psychoactive ingredient in ENDS solutions, is both highly addictive and toxic. In addition to nicotine, other toxicants, carcinogens, and metal particles have been detected in solutions and aerosols of ENDS. Nonusers are involuntarily exposed to the emissions of these devices with secondhand and thirdhand aerosol. The concentrated and often flavored nicotine in ENDS solutions poses a poisoning risk for young children. Reports of acute nicotine toxicity from US poison control centers have been increasing, with at least 1 child death reported from unintentional exposure to a nicotine-containing ENDS solution. With flavors, design, and marketing that appeal to youth, ENDS threaten to renormalize and glamorize nicotine and tobacco product use. There is a critical need for ENDS regulation, legislative action, and counter promotion to protect youth. ENDS have the potential to addict a new generation of youth to nicotine and reverse more than 50 years of progress in tobacco control. Copyright © 2015 by the American Academy of Pediatrics.

  14. The data-acquisition and second level trigger system for the ZEUS calorimeter

    International Nuclear Information System (INIS)

    Lugt, H.J. van der.

    1993-01-01

    ZEUS and HERA are introduced in chapter 1 with emphasis on the ZEUS Calorimeter and the ZEUS trigger system. The analog and digital electronics developed for the readout of the Calorimeter signals, and the hardware for the Calorimeter Second Level Trigger and data-acquisition system, is described in chapter 2. Emphasis is put on the hardware developed at NIKHEF, which is based on the transputer as the main processing element. The ZEUS trigger and data-acquisition environment as well as the calibration procedures needed for the Calorimeter impose several requirements on the design of the data-acquisition system. The requirements, their implications for the design of the transputer network architecture and the design itself, are described in detail in chapter 3. The software developed for the Calorimeter data-acquisition is described in chapter 4. It includes both the software for the Calorimeter data-acquisition as that required for the calibration of the Calorimeter. First experiences with the CAL-SLT algorithms, obtained during the 1992 HERA running periods, are presented in chapter 5. Chapter 6 discusses the performance of the Calorimeter data-acquisition system. (orig.)

  15. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  16. Multiple multichannel spectra acquisition and processing system with intelligent interface

    International Nuclear Information System (INIS)

    Chen Ying; Wei Yixiang; Qu Jianshi; Zheng Futang; Xu Shengkui; Xie Yuanming; Qu Xing; Ji Weitong; Qiu Xuehua

    1986-01-01

    A Multiple multichannel spectra acquisition and processing system with intelligent interface is described. Sixteen spectra measured with various lengths, channel widths, back biases and acquisition times can be identified and collected by the intelligent interface simultaneously while the connected computer is doing data processing. The execution time for the Ge(Li) gamma-ray spectrum analysis software on IBM PC-XT is about 55 seconds

  17. Design of gamma camera data acquisition system based on PCI9810

    International Nuclear Information System (INIS)

    Zhao Yuanyuan; Zhao Shujun; Liu Yang

    2004-01-01

    This paper describe the design of gamma camera's data acquisition system, which is based on PCI9810 data acquisition card of ADLink Technology Inc. The main function of PCI9810 and the program of data acquisition system are described. (authors)

  18. The data acquisition and control system for Thomson Scattering on ATF [Advanced Toroidal Facility

    International Nuclear Information System (INIS)

    Stewart, K.A.; Kindsfather, R.R.; Rasmussen, D.A.

    1989-01-01

    The 2-dimensional Thomson Scattering System measuring electron temperatures and densities in the Advanced Toroidal Facility (ATF) is interfaced to a VAX-8700 computer system running in a clustered configuration. Calibration, alignment, and operation of this diagnostic is under computer control. Extensive CAMAC instrumentation is used for timing control, data acquisition, and laser alignment. This paper will discuss the computer hardware and software, system operations, and data storage and retrieval. 3 refs

  19. Review of Supervisory Control and Data Acquisition (SCADA) Systems

    Energy Technology Data Exchange (ETDEWEB)

    Reva Nickelson; Briam Johnson; Ken Barnes

    2004-01-01

    A review using open source information was performed to obtain data related to Supervisory Control and Data Acquisition (SCADA) systems used to supervise and control domestic electric power generation, transmission, and distribution. This report provides the technical details for the types of systems used, system disposal, cyber and physical security measures, network connections, and a gap analysis of SCADA security holes.

  20. An universal multi-parameter data acquisition system MOLDAS1

    International Nuclear Information System (INIS)

    Jiao Dunpang; Zhou Yanyen; Ge Wenxiu; Wang Yanyu; Yu Jusheng; Jing Lan

    1988-01-01

    MOLDAS1 is a data acquisition system to be used for data-taking from reactions induced by heavy-ion in IMP. Its configuration both on hardware and software, system control logic, data flow and functions are intraduced. System specification is discussed as well

  1. A data acquisition and analysis system for the RIBLL

    CERN Document Server

    Wenlong, Z; Zhong Yan, G; Guoqing, X; Jin Chuan W; Jia Xing, L; Xiang Wei, M; Shanhong, J; Lijun, Q; Quanjin, W

    2000-01-01

    The Radioactive Ion Beam Line in Lanzhou (RIBLL) is described. This system has been connected to a 100 M Ethernet and is run on the NT platform of MS windows. The system has adopted CAMAC specification and incorporates PAW and CERNLIB from CERN. It is a powerful and flexible data acquisition and analysis system with a rate of ~640 Kb /s. (4 refs).

  2. An intelligent data acquisition system for fluid mechanics research

    Science.gov (United States)

    Cantwell, E. R.; Zilliac, G.; Fukunishi, Y.

    1989-01-01

    This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.

  3. Design and construction of the front-end electronics data acquisition for the SLD CRID [Cherenkov Ring Imaging Detector

    International Nuclear Information System (INIS)

    Hoeflich, J.; McShurley, D.; Marshall, D.; Oxoby, G.; Shapiro, S.; Stiles, P.; Spencer, E.

    1990-10-01

    We describe the front-end electronics for the Cherenkov Ring Imaging Detector (CRID) of the SLD at the Stanford Linear Accelerator Center. The design philosophy and implementation are discussed with emphasis on the low-noise hybrid amplifiers, signal processing and data acquisition electronics. The system receives signals from a highly efficient single-photo electron detector. These signals are shaped and amplified before being stored in an analog memory and processed by a digitizing system. The data from several ADCs are multiplexed and transmitted via fiber optics to the SLD FASTBUS system. We highlight the technologies used, as well as the space, power dissipation, and environmental constraints imposed on the system. 16 refs., 10 figs

  4. A versatile data acquisition system and the ISOL facility TRISTAN

    International Nuclear Information System (INIS)

    Gill, R.L.; Stelts, M.L.; Chrien, R.E.; Manzella, V.; Liou, H.; Shostak, S.

    1981-01-01

    We have constructed a versatile, modular data acquisition system to service experiments on TRISTAN and other nuclear research facilities at the HFBR using CAMAC interfacing. Standard, commercially-available electronic instruments and computer programs, such as FORTRAN and system routines, are used throughout. Simple interfaces have been built to adapt non-CAMAC equipment to CAMAC input registers. Up to eight different experiments can be multiplexed on the branch highway by a fast microprogrammed branch driver with a 4096 word memory. The branch driver delivers pre-processed data to a bus which links devices such as a central processor, 1 megaword core memory, tape drives, discs, display processor and terminal. The following features are offered: two 8192 channel pulse height analyzers, a 3-parameter coincidence unit, 4 multiscalers, a timed sequence of delayed γ-ray spectra (33 spectra of 4096 channels each), a 2-parameter (pulse height versus time-of-flight) analyzer, 16 scalers and 24 experimental interlocks. Up to 100 different spectra are available to users for display during an experiment. (orig./RW)

  5. Proceedings of the second data acquisition system workshop

    International Nuclear Information System (INIS)

    Ohska, T.K.

    1988-02-01

    The second data acquisition system workshop was held on July 18 and 19, 1986 at the National Laboratory for High Energy Physics (KEK). The organizers had one thing in mind when this workshop was planned. It was wanted to make a record of mistakes in designing and building the electronic system. The time when this workshop was held was just before the completion of the TRISTAN detectors when everyone was very busy. Brilliant achievements have been published every year in the world, but the hard earned experience on what should not be done does not appear on publication. To record it while it is still hot was the basic motivation of this workshop. More than 100 people attended the workshop, and some speakers did excellently what the organizers hoped to do, but some talked on their great achievements only. The organizers are very thankful to everybody who helped before, during and after the workshop. If possible, it should be asked all speakers to hand in their write-ups on the day of the workshop. Actually, the last write-up was received almost one year late, and the publication of this report delayed. In this book, those write-ups are collected. (Kako, I.)

  6. Operation of inspection data acquisition and evaluation system

    International Nuclear Information System (INIS)

    Takahashi, Yoichi; Harada, Hiroshi; Watanabe, Masayuki; Sakaguchi, Makoto; Ishikawa, Masayuki

    2016-01-01

    Rokkasho Reprocessing Plant (RRP) is a large scale plant to treat a huge amount of Plutonium significant for safeguards. The LArge SCAle Reprocessing plant safeguards (LASCAR) Forum recommended an effective utilization of unattended verification systems and automated data acquisition system etc. Based on LASCAR recommendation, Nuclear Material Control Center (NMCC) has developed the inspection data acquisition system as the automated data acquisition system from the unattended verification systems (including non-destructive assay equipment, solution monitoring system and surveillance camera). The data gathered from the unattended verification system are provided to the inspection data evaluation system for the State and the IAEA. In this development, redundancy concepts for data transfer line, in order to prevent inspection data missing, were introduced, and the timely confirmation of solution behaver such as material flows and inventories by the solution monitoring can be achieved. Furthermore, for purpose of efficiency of evaluation of inspection activity for the State, NMCC has developed the inspection data evaluation system which operates automated partition of inspection data coming from each verification equipment. Additionally, the inspection data system evaluation can manage the inspection activities and their efforts. These development and operation have been funded by JSGO (Japan Safeguards Office). This paper describes development history and operation of the inspection data acquisition and evaluation system. (author)

  7. Parallel preprocessing in a nuclear data acquisition system

    International Nuclear Information System (INIS)

    Pichot, G.; Auriol, E.; Lemarchand, G.; Millaud, J.

    1977-01-01

    The appearance of microprocessors and large memory chips has somewhat modified the spectrum of tools usable by the data acquisition system designer. This is particular true in the nuclear research field where the data flow has been continuously growing as a consequence of the increasing capabilities of new detectors. This paper deals with the insertion, between a data acquisition system and a computer, of a preprocessing structure based on microprocessors and large capacity high speed memories. The results shows a significant improvement on several aspects in the operation of the system with returns paying back the investments in 18 months

  8. How Cisco Systems Used Enterprise Architecture Capability to Sustain Acquisition-Based Growth

    DEFF Research Database (Denmark)

    Toppenberg, Gustav; Shanks, Graeme; Henningsson, Stefan

    2015-01-01

    Value-creating acquisitions are a major challenge for many firms. The case of Cisco Systems shows that an advanced enterprise architecture (EA) capability can contribute to the four phases of the acquisition process: pre-acquisition preparation, acquisition selection, acquisition integration...... and post-integration management. Cisco’s EA capability improves its ability to rapidly capture value from acquisitions and to sustain its acquisition-based growth strategy over time....

  9. Thermal Gradient Data Acquisition System Documentation

    National Research Council Canada - National Science Library

    Walker, Larry D; Robinson, Scott B; Leon, Lisa

    2004-01-01

    ... that can be recorded in mice. Since acceptable commercial systems are not available, this system was custom-built to acquire data using National Instruments' versatile hardware components and LabVIEW...

  10. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  11. An updated data acquisition and analysis system at RIBLL

    International Nuclear Information System (INIS)

    Chen, Z.Q.; Ye, Y.L.; Zhan, W.L.; Xiao, G.Q.; Guo, Z.Y.; Xu, H.S.; Wang, J.C.; Jiang, D.X.; Wang, Q.J.; Zheng, T.; Zhang, G.L.; Wu, C.E.; Li, Z.H.; Li, X.Q.; Hu, Q.Y.; Pang, D.Y.; Wang, J.

    2005-01-01

    An updated data acquisition and analysis system for beam tuning and nuclear physics experiments at RIBLL is presented. The system hardware is based on standard CAMAC bus with SCSI KSC3929-Z1B crate controller. The system software has a user-friendly GUI which is written in C/C++ language using Microsoft Visual C++ .Net 2003 with ROOT class library and runs under PC-based Windows 2000 operating system. The performance of the DAQ system is reliable and safe

  12. Design considerations for a multiprocessor based data acquisition system

    International Nuclear Information System (INIS)

    Tippie, J.W.; Kulaga, J.E.

    1979-01-01

    The rapid advance of digital technology has provided the systems designer with many new design options. Hardware is no longer the controlling expense. Complex operating systems provide the flexibility and development tools needed by software designers, but restrict throughput. Multiprocessor-based systems can be used to ''front-end'' high-throughput applications while maintaining the many advantages offered by multitasking operating systems. The design of a high-throughput data acquisition system for application in low energy nuclear physics is considered

  13. Reliability of electronic systems

    International Nuclear Information System (INIS)

    Roca, Jose L.

    2001-01-01

    Reliability techniques have been developed subsequently as a need of the diverse engineering disciplines, nevertheless they are not few those that think they have been work a lot on reliability before the same word was used in the current context. Military, space and nuclear industries were the first ones that have been involved in this topic, however not only in these environments it is that it has been carried out this small great revolution in benefit of the increase of the reliability figures of the products of those industries, but rather it has extended to the whole industry. The fact of the massive production, characteristic of the current industries, drove four decades ago, to the fall of the reliability of its products, on one hand, because the massively itself and, for other, to the recently discovered and even not stabilized industrial techniques. Industry should be changed according to those two new requirements, creating products of medium complexity and assuring an enough reliability appropriated to production costs and controls. Reliability began to be integral part of the manufactured product. Facing this philosophy, the book describes reliability techniques applied to electronics systems and provides a coherent and rigorous framework for these diverse activities providing a unifying scientific basis for the entire subject. It consists of eight chapters plus a lot of statistical tables and an extensive annotated bibliography. Chapters embrace the following topics: 1- Introduction to Reliability; 2- Basic Mathematical Concepts; 3- Catastrophic Failure Models; 4-Parametric Failure Models; 5- Systems Reliability; 6- Reliability in Design and Project; 7- Reliability Tests; 8- Software Reliability. This book is in Spanish language and has a potentially diverse audience as a text book from academic to industrial courses. (author)

  14. The ATLAS Data Acquisition and High Level Trigger system

    International Nuclear Information System (INIS)

    2016-01-01

    This paper describes the data acquisition and high level trigger system of the ATLAS experiment at the Large Hadron Collider at CERN, as deployed during Run 1. Data flow as well as control, configuration and monitoring aspects are addressed. An overview of the functionality of the system and of its performance is presented and design choices are discussed.

  15. Migrating Legacy Systems in the Global Merger & Acquisition Environment

    Science.gov (United States)

    Katerattanakul, Pairin; Kam, Hwee-Joo; Lee, James J.; Hong, Soongoo

    2009-01-01

    The MetaFrame system migration project at WorldPharma, while driven by merger and acquisition, had faced complexities caused by both technical challenges and organizational issues in the climate of uncertainties. However, WorldPharma still insisted on instigating this post-merger system migration project. This project served to (1) consolidate the…

  16. A data-acquisition system for high speed linear CCD

    International Nuclear Information System (INIS)

    Liu Zhiyan; Chen Xiangcai; Jiang Xiaoshan; Zhang Hongyu; Liang Zhongwang; Xiang Haisheng; Hu Jun

    2010-01-01

    A data-acquisition system for high speed linear CCD (Charge Coupled device) is mainly introduced. The optical fiber transmission technology is used. The data is sent to PC through USB or PCI interface. The construction of the system, the design of the PCI interface hardware, software design and the design of the control program running on host computer are also introduced. (authors)

  17. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  18. Data acquisition system for linear PSD based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, Anita; Ghodgaonkar, M.D.

    2001-01-01

    Single or multi-PSD configurations are used in different neutron diffractometer setups. A data acquisition system is developed to serve the gross requirements of all the diffractometer setups. It is also customized to specific requirements of different setups. The hardware is developed as a Transputer based add-on card. Most of the hardware functionality is handled in the Transputer program thus improving throughput of the system. The card can handle 16 RDCs, a few motor controls and on/off controls. The software comprises of a front-end Windows98 application, a Transputer program and a device driver. The data acquisition system performs data acquisition, analysis, display and storage. Analysis includes converting raw data of linear PSD to equiangular format, merging and clubbing the data to make a continuous equiangular spectrum. Calibration of individual PSD is a crucial activity in correctly merging the data coming from PSDs. (author)

  19. A multi-parameter, acquisition system positron annihilation lifetime spectrometer

    International Nuclear Information System (INIS)

    Sharshar, T.

    2004-01-01

    A positron annihilation lifetime spectrometer employing a multi-parameter acquisition system has been prepared for various purposes such as the investigation and characterization of solid-state materials. The fast-fast coincidence technique was used in the present spectrometer with a pair of plastic scintillation detectors. The acquisition system is based on the Kmax software and on CAMAC modules. The data are acquired in event-by-event list mode. The time spectrum for the desired energy windows can be obtained by off-line data sorting and analysis. The spectrometer for event-by-event data acquisition is an important step to construct a positron age-momentum correlation (AMOC) spectrometer. The AMOC technique is especially suited for the observation of positron transitions between different states during their lifetime. The system performance was tested and the results were presented and discussed

  20. Hardware overview of the EUROGAM data acquisition system

    International Nuclear Information System (INIS)

    Alexander, J.; Owen, E.C.G.; Lazaurs, I.; McPherson, G.M.; Beck, F.A.; Ring, C.; Ender, C.; Pouxe, J.; Richard, A.

    1992-01-01

    This paper reports on EUROGAM, an Anglo/French ray detector which will alternate between the tandem Van der Graaf accelerator at Daresbury and the Vivitron at Strasbourg. Because of the very sensitive nature of the electronics for Germanium gamma ray detection, VXIbus (VMEbus extensions for instrumentation) was chosen as the basis for data acquisition. A major program of development, shared between the British and French participants, is now in its final stages for operation in early 1992

  1. Timing performances of a data acquisition system for Time of Flight PET

    International Nuclear Information System (INIS)

    Morrocchi, Matteo; Marcatili, Sara; Belcari, Nicola; Bisogni, Maria G.; Collazuol, Gianmaria; Ambrosi, Giovanni; Corsi, Francesco; Foresta, Maurizio; Marzocca, Cristoforo; Matarrese, Gianvito; Sportelli, Giancarlo; Guerra, Pedro; Santos, Andres; Del Guerra, Alberto

    2012-01-01

    We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm 2 of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.

  2. Timing performances of a data acquisition system for Time of Flight PET

    Energy Technology Data Exchange (ETDEWEB)

    Morrocchi, Matteo, E-mail: matteo.morrocchi@pi.infn.it [University of Pisa and INFN Sezione di Pisa, I 56127 Pisa (Italy); Marcatili, Sara; Belcari, Nicola; Bisogni, Maria G. [University of Pisa and INFN Sezione di Pisa, I 56127 Pisa (Italy); Collazuol, Gianmaria [University of Padova and INFN Sezione di Padova (Italy); Ambrosi, Giovanni [INFN Sezione di Perugia, I 06100 Perugia (Italy); Corsi, Francesco; Foresta, Maurizio; Marzocca, Cristoforo; Matarrese, Gianvito [Politecnico di Bari and INFN Sezione di Bari, I 70100 Bari (Italy); Sportelli, Giancarlo; Guerra, Pedro; Santos, Andres [Universidad Politecnica de Madrid, E 28040 Madrid (Spain); Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Del Guerra, Alberto [University of Pisa and INFN Sezione di Pisa, I 56127 Pisa (Italy)

    2012-12-11

    We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm{sup 2} of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.

  3. A VMEbus general-purpose data acquisition system

    International Nuclear Information System (INIS)

    Ninane, A.; Nemry, M.; Martou, J.L.; Somers, F.

    1992-01-01

    We present a general-purpose, VMEbus based, multiprocessor data acquisition and monitoring system. Events, handled by a master CPU, are kept at the disposal of data storage and monitoring processes which can run on distinct processors. They access either the complete set of data or a fraction of them, minimizing the acquisition dead-time. The system is built with the VxWorks 5.0 real time kernel to which we have added device drivers for data acquisition and monitoring. The acquisition is controlled and the data are displayed on a workstation. The user interface is written in C ++ and re-uses the classes of the Interviews and the NIH libraries. The communication between the control workstation and the VMEbus processors is made through SUN RPCs on an Ethernet link. The system will be used for, CAMAC based, data acquisition for nuclear physics experiments as well as for the VXI data taking with the 4π configuration (100 neutron detectors) of the Brussels-Caen-Louvian-Strasbourg DEMON collaboration. (author)

  4. Waste retrieval sluicing system data acquisition system acceptance test report

    International Nuclear Information System (INIS)

    Bevins, R.R.

    1998-01-01

    This document describes the test procedure for the Project W-320 Tank C-106 Sluicing Data Acquisition System (W-320 DAS). The Software Test portion will test items identified in the WRSS DAS System Description (SD), HNF-2115. Traceability to HNF-2115 will be via a reference that follows in parenthesis, after the test section title. The Field Test portion will test sensor operability, analog to digital conversion, and alarm setpoints for field instrumentation. The W-320 DAS supplies data to assist thermal modeling of tanks 241-C-106 and 241-AY-102. It is designed to be a central repository for information from sources that would otherwise have to be read, recorded, and integrated manually. Thus, completion of the DAS requires communication with several different data collection devices and output to a usable PC data formats. This test procedure will demonstrate that the DAS functions as required by the project requirements stated in Section 3 of the W-320 DAS System Description, HNF-2115

  5. Data acquisition system for a proton imaging apparatus

    CERN Document Server

    Sipala, V; Bruzzi, M; Bucciolini, M; Candiano, G; Capineri, L; Cirrone, G A P; Civinini, C; Cuttone, G; Lo Presti, D; Marrazzo, L; Mazzaglia, E; Menichelli, D; Randazzo, N; Talamonti, C; Tesi, M; Valentini, S

    2009-01-01

    New developments in the proton-therapy field for cancer treatments, leaded Italian physics researchers to realize a proton imaging apparatus consisting of a silicon microstrip tracker to reconstruct the proton trajectories and a calorimeter to measure their residual energy. For clinical requirements, the detectors used and the data acquisition system should be able to sustain about 1 MHz proton rate. The tracker read-out, using an ASICs developed by the collaboration, acquires the signals detector and sends data in parallel to an FPGA. The YAG:Ce calorimeter generates also the global trigger. The data acquisition system and the results obtained in the calibration phase are presented and discussed.

  6. An Overview of Advanced Data Acquisition System (ADAS)

    Science.gov (United States)

    Mata, Carlos T.; Steinrock, T. (Technical Monitor)

    2001-01-01

    The paper discusses the following: 1. Historical background. 2. What is ADAS? 3. R and D status. 4. Reliability/cost examples (1, 2, and 3). 5. What's new? 6. Technical advantages. 7. NASA relevance. 8. NASA plans/options. 9. Remaining R and D. 10. Applications. 11. Product benefits. 11. Commercial advantages. 12. intellectual property. Aerospace industry requires highly reliable data acquisition systems. Traditional Acquisition systems employ end-to-end hardware and software redundancy. Typically, redundancy adds weight, cost, power consumption, and complexity.

  7. CORBA technology in reengineering the FTU data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Bertocchi, A; Buceti, G; Centioli, C; Di Muzio, D; Iannone, F.; Panella, M; Vitale, V

    2002-06-01

    In its early stages, Frascati tokamak upgrade DAS was essentially devoted to acquiring data from experiments in CAMAC standard, using a software system (code and database) entirely written by domestic professionals. In 15 years of life DAS has been growing in size and complexity, still preserving its original structure; at the same time new standards were introduced (VME, PCI) to take into account users' ever increasing demands for amount of data and acquisition frequency with which the existing code couldn't cope. Moreover, machines were getting old and the maintenance became troublesome. Finally, the data archive porting to Unix has definitely shown that the DAS system was ageing and a thorough redesign was needed. The system we are planning to introduce is founded on a standard CORBA bus: (i) to integrate heterogeneous platforms and define a standard layer for interactions between the different acquisition units; (ii) to grant, with open source tools (MySql) and interfaces (Html and Java), unified access to hardware and software configuration data. So, a dedicated PC server, connected via a suitable PCI serial highway driver card, will perform the CAMAC access for all the clients interacting through the CORBA layer. Up to now we have successfully tested CAMAC access, and we designed an acquisition unit, which will be the building block of the new system. The next step will be migrating to Alpha/VMS the software related to CAMAC data acquisition, which has been so far the cornerstone of the whole DAS; it will be completely redesigned to fit the 'acquisition unit' paradigm we have defined. Finally we will have a fully distributed data acquisition system with VME (at present six such units have been operating since 1999) and PCI stations, an Alpha/VMS client of the CAMAC/PC server and any possible platform interacting through a CORBA bus for getting data configuration, synchronisation and data archiving.

  8. CORBA technology in reengineering the FTU data acquisition system

    International Nuclear Information System (INIS)

    Bertocchi, A.; Buceti, G.; Centioli, C.; Di Muzio, D.; Iannone, F.; Panella, M.; Vitale, V.

    2002-01-01

    In its early stages, Frascati tokamak upgrade DAS was essentially devoted to acquiring data from experiments in CAMAC standard, using a software system (code and database) entirely written by domestic professionals. In 15 years of life DAS has been growing in size and complexity, still preserving its original structure; at the same time new standards were introduced (VME, PCI) to take into account users' ever increasing demands for amount of data and acquisition frequency with which the existing code couldn't cope. Moreover, machines were getting old and the maintenance became troublesome. Finally, the data archive porting to Unix has definitely shown that the DAS system was ageing and a thorough redesign was needed. The system we are planning to introduce is founded on a standard CORBA bus: (i) to integrate heterogeneous platforms and define a standard layer for interactions between the different acquisition units; (ii) to grant, with open source tools (MySql) and interfaces (Html and Java), unified access to hardware and software configuration data. So, a dedicated PC server, connected via a suitable PCI serial highway driver card, will perform the CAMAC access for all the clients interacting through the CORBA layer. Up to now we have successfully tested CAMAC access, and we designed an acquisition unit, which will be the building block of the new system. The next step will be migrating to Alpha/VMS the software related to CAMAC data acquisition, which has been so far the cornerstone of the whole DAS; it will be completely redesigned to fit the 'acquisition unit' paradigm we have defined. Finally we will have a fully distributed data acquisition system with VME (at present six such units have been operating since 1999) and PCI stations, an Alpha/VMS client of the CAMAC/PC server and any possible platform interacting through a CORBA bus for getting data configuration, synchronisation and data archiving

  9. Intelligent Acquisition System Used in Mechanical Laboratory

    Directory of Open Access Journals (Sweden)

    Rob Raluca

    2016-01-01

    Full Text Available The main purpose of this paper consists in determining of the parameters which characterize the functioning of the Teves MK 60 as an ABS-ESP braking laboratory stand. This braking system model is used by the Volkswagen Golf and Bora the since 2002. The braking laboratory stand is able to simulate many operations which are able to give information concerning the ABS-ESP braking system comparing to the classical braking system. An application designed in LabVIEW comes to acquire and to process in real time the electrical signals generated by the Teves MK 60 laboratory stand.

  10. Novel electron gas systems

    International Nuclear Information System (INIS)

    Senatore, G.; Rapisarda, F.; Conti, S.

    1998-01-01

    We review recent progress on the physics of electrons in the bilayered electron gas, relevant to coupled quantum wells in GaAs/AIGaAs heterostructures. First we focus on the phase diagram of a symmetric bilayer at T = B = 0, obtained by diffusion Monte Carlo (DMC) simulations. It is found that inter-layer correlations stabilize crystalline structures at intermediate inter-layer separation, while favoring a liquid phase at smaller distance. Also, the available DMC evidence is in contrast with the recently (Hartree-Fock) predicted total charge transfer (TCT), whereby all the electron spontaneously jump in one layer. In fact, one can show that such a TCT state is never stable in the ideal bilayer with no tunneling. We finally comment on ongoing DMC investigations on the electron-hole bilayer, where excitonic condensation is expected to take place. (Copyright (1998) World Scientific Publishing Co. Pte. Ltd)

  11. Acquisition System Verification for Energy Efficiency Analysis of Building Materials

    Directory of Open Access Journals (Sweden)

    Natalia Cid

    2017-08-01

    Full Text Available Climate change and fossil fuel depletion foster interest in improving energy efficiency in buildings. There are different methods to achieve improved efficiency; one of them is the use of additives, such as phase change materials (PCMs. To prove this method’s effectiveness, a building’s behaviour should be monitored and analysed. This paper describes an acquisition system developed for monitoring buildings based on Supervisory Control and Data Acquisition (SCADA and with a 1-wire bus network as the communication system. The system is empirically tested to prove that it works properly. With this purpose, two experimental cubicles are made of self-compacting concrete panels, one of which has a PCM as an additive to improve its energy storage properties. Both cubicles have the same dimensions and orientation, and they are separated by six feet to avoid shadows. The behaviour of the PCM was observed with the acquisition system, achieving results that illustrate the differences between the cubicles directly related to the PCM’s characteristics. Data collection devices included in the system were temperature sensors, some of which were embedded in the walls, as well as humidity sensors, heat flux density sensors, a weather station and energy counters. The analysis of the results shows agreement with previous studies of PCM addition; therefore, the acquisition system is suitable for this application.

  12. Distributed data acquisition system for Pachmarhi array of Cverenkov telescopes

    Science.gov (United States)

    Upadhya, S. S.; Acharya, B. S.; Bhat, P. N.; Chitnis, V. R.; D'Souza, A. I.; Francis, P. J.; Gothe, K. S.; Joshi, S. R.; Majumdar, P.; Manogaran, M.; Nagesh, B. K.; Pose, M. S.; Purohit, P. N.; Rahman, M. A.; Rao, K. K.; Rao, S. K.; Sharma, S. K.; Singh, B. B.; Stanislaus, A. J.; Sudersanan, P. V.; Venkatesh Murthy, B. L.; Vishwanath, P. R.

    2002-03-01

    Pachmarhi Array of Cverenkov Telescopes consists of 25 Telescopes distributed within an area of 8000m2. The array was designed to detect and process faint Cverenkov light flashes that lasts for a few nanoseconds, produced in the atmosphere by celestial VHE ?-rays or cosmic rays. In this experiment, the arrival time and amplitude of fast tiny pulses have to be measured and recorded from each of 175 photo-tubes in a shortest possible time. In view of the complexity of the system, the entire array is divided into 4 sectors. A Distributed Data Acquisition System developed for the purpose consists of independent Sector Data Acquisition Systems and a Master Data Acquisition System. The distributed data acquisition and monitoring system are built using PC's which are networked through LAN. The entire software for DDAS was developed in-house in C language under LINUX environment. Also, most of the hardware barring a few fast digitization modules were designed and fabricated in-house. The design features, implementation strategy as well as the performance of the whole system are discussed.

  13. Design and Performance of the Data Acquisition System for the NA61/SHINE Experiment at CERN

    CERN Document Server

    Laszlo, Andras; Fodor, Zoltan; Kiss, Tivadar; Kleinfelder, Stuart; Soos, Csaba; Tefelski, Dariusz; Tolyhi, Tamas; Vesztergombi, Gyorgy; Wyszynski, Oskar

    2015-01-01

    This paper describes the hardware, firmware and software systems used in data acquisition for the NA61/SHINE experiment at the CERN SPS accelerator. Special emphasis is given to the design parameters of the readout electronics for the 40 m^3 volume Time Projection Chamber detectors as these give the largest contribution to event data among all the subdetectors: events consisting of 8 bit ADC values from 256 time slices of 200 k electronic channels are to be read out with order of ~100 Hz readout rate. As the data acquisition system is organized in `push data mode', i.e. local systems transmit data asynchronously, techniques of solving subevent synchronization is also discussed.

  14. A fast data acquisition system for PHA and MCS measurements

    International Nuclear Information System (INIS)

    Eijk, P.J.A. van; Keyser, C.J.; Rigterink, B.J.; Hasper, H.

    1985-01-01

    A microprocessor controlled data acquisition system for pulse height analysis and multichannel scaling is described. A 4K x 24 bit static memory is used to obtain a fast data acquisition rate. The system can store 12 bit ADC or TDC data within 150 ns. Operating commands can be entered via a small keyboard or by a RS-232-C interface. An oscilloscope is used to display a spectrum. The display of a spectrum or the transmission of spectrum data to an external computer causes only a short interruption of a measurement in progress and is accomplished by using a DMA circuit. The program is written in Modular Pascal and is divided into 15 modules. These implement 9 parallel processes which are synchronized by using semaphores. Hardware interrupts from the data acquisition, DMA, keyboard and RS-232-C circuits are used to signal these processes. (orig.)

  15. Implementation of High Speed Distributed Data Acquisition System

    Science.gov (United States)

    Raju, Anju P.; Sekhar, Ambika

    2012-09-01

    This paper introduces a high speed distributed data acquisition system based on a field programmable gate array (FPGA). The aim is to develop a "distributed" data acquisition interface. The development of instruments such as personal computers and engineering workstations based on "standard" platforms is the motivation behind this effort. Using standard platforms as the controlling unit allows independence in hardware from a particular vendor and hardware platform. The distributed approach also has advantages from a functional point of view: acquisition resources become available to multiple instruments; the acquisition front-end can be physically remote from the rest of the instrument. High speed data acquisition system transmits data faster to a remote computer system through Ethernet interface. The data is acquired through 16 analog input channels. The input data commands are multiplexed and digitized and then the data is stored in 1K buffer for each input channel. The main control unit in this design is the 16 bit processor implemented in the FPGA. This 16 bit processor is used to set up and initialize the data source and the Ethernet controller, as well as control the flow of data from the memory element to the NIC. Using this processor we can initialize and control the different configuration registers in the Ethernet controller in a easy manner. Then these data packets are sending to the remote PC through the Ethernet interface. The main advantages of the using FPGA as standard platform are its flexibility, low power consumption, short design duration, fast time to market, programmability and high density. The main advantages of using Ethernet controller AX88796 over others are its non PCI interface, the presence of embedded SRAM where transmit and reception buffers are located and high-performance SRAM-like interface. The paper introduces the implementation of the distributed data acquisition using FPGA by VHDL. The main advantages of this system are high

  16. Command & Control (C2) Systems Acquisition Study

    Science.gov (United States)

    1982-09-01

    34: 0 The movement of substantial capability closer to individual users with significant improvements in the interface between the user and the system...description of the overall capability desired; (2) an archi- teLLural framework where evolution can occur with minimum subsequent redesign; and (3) a

  17. Control and data acquisition electronics for the CDF Silicon Vertex Detector

    Energy Technology Data Exchange (ETDEWEB)

    Turner, K.J.; Nelson, C.A.; Shaw, T.M.; Wesson, T.R.

    1991-11-01

    A control and data acquisition system has been designed for the CDF Silicon Vertex Detector (SVX) at Fermilab. The system controls the operation of the SVX Rev D integrated circuit (SVX IC) that is used to instrument a 46,000 microstrip silicon detector. The system consists of a Fastbus Sequencer, a Crate Controller and Digitizer modules. 11 refs., 6 figs., 3 tabs.

  18. Control and data acquisition electronics for the CDF silicon vertex detector

    International Nuclear Information System (INIS)

    urner, K.J.; Nelson, C.A.; Shaw, T.M.; Wesson, T.R.

    1992-01-01

    This paper reports on a control and data acquisition system that has been designed for the CDF Silicon Vertex Detector (SVX) at Fermilab. The system controls the operation of the SVX Rev D integrated circuit (SVX IC) that is used to instrument a 46,000 microstrip silicon detector. The system consists of a Fastbus Sequencer, a Crate Controller and Digitizer modules

  19. Control and data acquisition electronics for the CDF Silicon Vertex Detector

    International Nuclear Information System (INIS)

    Turner, K.J.; Nelson, C.A.; Shaw, T.M.; Wesson, T.R.

    1991-11-01

    A control and data acquisition system has been designed for the CDF Silicon Vertex Detector (SVX) at Fermilab. The system controls the operation of the SVX Rev D integrated circuit (SVX IC) that is used to instrument a 46,000 microstrip silicon detector. The system consists of a Fastbus Sequencer, a Crate Controller and Digitizer modules. 11 refs., 6 figs., 3 tabs

  20. Development of data acquisition software for VME based system

    International Nuclear Information System (INIS)

    Kumar, A.; Chatterjee, A.; Mahata, K.; Ramachandran, K.

    2012-01-01

    A data acquisition system for VME has been developed for use in accelerator based experiments. The development was motivated by the growing demand for higher throughput in view of the increasing size of experiments. VME based data acquisition system provides a powerful alternative to CAMAC standards on account of higher readout speeds (100 ns/word) resulting in reduced dead time. Further, high density VME modules are capable of providing up to 640 channels in a single VME crate with 21 slots. The software system LAMPS, earlier developed for CAMAC based system and used extensively in our laboratory and elsewhere has been modified for the present VME based system. The system makes use of the VME library to implement Chain Block Transfer Readout (CBLT) and gives the option of both Polling and Interrupt mode to acquire data. Practical throughput of ∼ 250 ns/word in zero suppressed mode has been achieved. (author)

  1. Data-acquisition systems for the present and the future

    International Nuclear Information System (INIS)

    Drobnis, D.D.

    1982-09-01

    Basic components of today's acquisition systems are surveyed. These include front-end tools such as microprocessors, programmable controllers, and CAMAC interfaces. Some key concepts in large central real-time systems are examined: Hardware and Software architecture, and data base structure. Some trends in present data acquisition system design are analyzed, including increasing distribution of system functions and expansion to hierarchical multi-processor netowrks. With the evolution of microprocessors, front-end intelligence is growing into front-end computing power. Real-time host systems are becoming increasingly sophisticated human interface and data base management tools, with increasingly complex operating systems, and increasing amounts of memory, mass storage, and computing power. And the ultimate analysis of plasma data is becoming increasingly sophisticated

  2. [Electronic poison information management system].

    Science.gov (United States)

    Kabata, Piotr; Waldman, Wojciech; Kaletha, Krystian; Sein Anand, Jacek

    2013-01-01

    We describe deployment of electronic toxicological information database in poison control center of Pomeranian Center of Toxicology. System was based on Google Apps technology, by Google Inc., using electronic, web-based forms and data tables. During first 6 months from system deployment, we used it to archive 1471 poisoning cases, prepare monthly poisoning reports and facilitate statistical analysis of data. Electronic database usage made Poison Center work much easier.

  3. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  4. Automated system for acquisition and image processing for the control and monitoring boned nopal

    Science.gov (United States)

    Luevano, E.; de Posada, E.; Arronte, M.; Ponce, L.; Flores, T.

    2013-11-01

    This paper describes the design and fabrication of a system for acquisition and image processing to control the removal of thorns nopal vegetable (Opuntia ficus indica) in an automated machine that uses pulses of a laser of Nd: YAG. The areolas, areas where thorns grow on the bark of the Nopal, are located applying segmentation algorithms to the images obtained by a CCD. Once the position of the areolas is known, coordinates are sent to a motors system that controls the laser to interact with all areolas and remove the thorns of the nopal. The electronic system comprises a video decoder, memory for image and software storage, and digital signal processor for system control. The firmware programmed tasks on acquisition, preprocessing, segmentation, recognition and interpretation of the areolas. This system achievement identifying areolas and generating table of coordinates of them, which will be send the motor galvo system that controls the laser for removal

  5. A camac data acquisition system based on PC-Linux

    International Nuclear Information System (INIS)

    Ribas, R.V.

    2002-01-01

    A multi-parametric data acquisition system for Nuclear Physics experiments using camac instrumentation on a personal computer with the Linux operating system in described. The system is very reliable, inexpensive and is capable of handling event rates up to 4-6 k events/s. In the present version, the maximum number of parameters to be acquired is limited only by the number of camac modules that can be fitted in one camac crate

  6. Decal electronics for printed high performance cmos electronic systems

    KAUST Repository

    Hussain, Muhammad Mustafa; Sevilla, Galo Torres; Cordero, Marlon Diaz; Kutbee, Arwa T.

    2017-01-01

    High performance complementary metal oxide semiconductor (CMOS) electronics are critical for any full-fledged electronic system. However, state-of-the-art CMOS electronics are rigid and bulky making them unusable for flexible electronic applications

  7. Data acquisition systems for high energy physics experiments

    International Nuclear Information System (INIS)

    Duran, I.; Olmos, P.

    1986-01-01

    The Data Acquisition Systems most frequently used in High Energy Physics experiments is described. This report begins with a brief description of the main elements of a typical signal processing chain, following with a detailed exposition of the four most popular instrumentation standards used in this kind of experiments: NIM, CAMAC, and VMI. (author). 20 figs., 9 ref

  8. A status report on the SLD data acquisition system

    International Nuclear Information System (INIS)

    1988-11-01

    The basic design of the SLD data acquisition system and its present status are reviewed. Aspects of the design that take particular advantage of the relatively low e + e/sup /minus// cross section and the low beam crossing rate of a linear collider are explained. 14 refs., 8 figs

  9. The data acquisition system for the HERA H1 experiment

    International Nuclear Information System (INIS)

    Haynes, W.J.

    1990-06-01

    The HERA ep collider will set new challenges for the acquisition of data from large particle physics experiments. Short bunch-crossing times combined with high data rates imply sophisticated designs based on current technology. This paper describes how a multi-microprocessor system is being used at the H1 experiment. (author)

  10. The implement of java based GUI for data acquisition system

    International Nuclear Information System (INIS)

    Yang Xiaoqing

    2003-01-01

    Web based technique have been used to produce a Graphic User Interface framework for small Data Acquisition System. A CORBA library used for the communication with the JRCS servers. The GUI was implemented by Java Swing. the integration between Java and CORBA provide a powerful independent distributed environment. (authors)

  11. Application Features of Language Acquisition Assessment System in Kazakhstan: KAZTEST

    Science.gov (United States)

    Dinayeva, Bekzat B.; Sapina, Sabira M.; Utanova, Aizada K.; Aitova, Nurlykhan N.

    2016-01-01

    The article deals with the analysis of peculiarities of language acquisition assessment system in Kazakhstan--KAZTEST. The author pays attention to the role of control as a way of assessment students' skills, habits and knowledge. In addition, author determined the place and functions of tests as a form of control. The author explores the…

  12. Data acquisition systems for high energy Physics experiments

    International Nuclear Information System (INIS)

    Duran, I.; Olmos, P.

    1986-01-01

    We describe here the Data Acquisition Systems most frequently used in High Energy Physics experiments. This report begins with a brief description of the main elements of a typical signal processing chain, following with a detailed exposition of the four most popular instrumentation standards used in this kind of experimental: NIM, CAMAC, FASTBUS and VME. (Author) 9 refs

  13. Bell Laboratories Book Acquisition, Accounting and Cataloging System (BELLTIP).

    Science.gov (United States)

    Sipfle, William K.

    BELLTIP is an on-line library processing system concerned with book acquisitions, cataloging, and financial accounting for a newwork of 26 technical libraries. At its center is an interactively updated and queried set of files concerned with all items currently in process. Principal products include all purchase orders, claims, and cancellations;…

  14. System of acquisition and analysis of ultrasonic data

    International Nuclear Information System (INIS)

    Vaubert, Y.; Birac, A.M.; Saglio, R.

    1982-08-01

    An original system of acquisition and analysis of ultrasonic data collected during examinations named STADUS-PRODUS has been developed by C.E.A. in Saclay. First developed for the needs of in-service inspection of PWR vessels, it is now used for the different automatic ultrasonic controls with various tools

  15. The acquisition system for Tore Supra 1000 s discharges

    International Nuclear Information System (INIS)

    Guillerminet, B.; How, J.

    2000-01-01

    Long duration discharges are planned for Tore Supra in the near future. A study has been made to detect and correct all the possible limitations of the data acquisition system. Results and analysis of a few 1000 s 'dry-run' test pulses are presented in this paper as well as the solutions foreseen for Tore Supra

  16. Control and data acquisition system for rotary compressor

    Directory of Open Access Journals (Sweden)

    Buczaj Marcin

    2017-01-01

    Full Text Available The rotary compressor (crimping machine is a machine designed for making hollow forgings. The rotary compressor is a prototype device designed and built at the Technical University of Lublin. The compressor is dedicated to perform laboratory tests related to the hollow forgings of various shapes using different materials. Since the rotary compressor is an experimental device, there is no control and acquisition data system available. The article presents the concept and the capabilities of the computer control and data acquisition system supporting rotary compressing process. The main task of software system is acquisition of force and kinetic parameters related to the analysed process of the rotary forging compression. The software allows the user to declare the course of the forming forgings. This system allows current recording and analysis of four physical values: feed rate (speed of working head movement, hydraulic oil pressure at inlet and outlet of hydraulic cylinder and the torque of engine. Application functions can be divided into three groups: the configuration of the pressing process, the acquisition and analysis of data from the pressing process and the recording and presentation of stored results. The article contains a detailed description about hardware and software implementation of mentioned functions.

  17. 40 CFR 205.54-2 - Sound data acquisition system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Sound data acquisition system. 205.54-2 Section 205.54-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound...

  18. Privacy Impact Assessment for the EPA Acquisition System

    Science.gov (United States)

    The EPA Acquisition System collects data on the business process of acquiring goods in support of the Agency's mission. Learn how this data is collected, how it will be used, access to the data, the purpose of data collection, and record retention policies

  19. A microprocessor based multiscaling data acquisition system for moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Bohm, C.; Ekdahl, T.

    1985-01-01

    A microprocessor based data acquisition system is described, which was developed for use in Moessbauer spectroscopy. It is designed to record two spectra simultaneously, one of which could be a calibration spectrum. It is autonomous, but uses a host computer for initialization and permanent storage of data. The host communication software is also described. (Author)

  20. Engineered barrier experiment. Power control and data acquisition systems

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J.M.; Gamero, E.; Martin, P.L.; Molinero, A.; Navarrete, J.J.; Yuste, C.

    1997-01-01

    The engineered barrier concept for the storage of radioactive wastes is being tested at almost full scale at CIEMAT facilities. A data acquisition and control is an element of this experiment. This system would be operating for next three years. (Author)

  1. The data acquisition system for the TASSO experiment

    International Nuclear Information System (INIS)

    Quarrie, D.R.

    1981-06-01

    The TASSO experiment at PETRA uses a Norsk Data NORD-10S for monitoring and control of the experiment. Trigger rates of typically 1 to 10 Hz are accepted and data are sent via a high speed link to the Central DESY IBM Triplex for later off-line analysis. This data acquisition system is described. (author)

  2. A remote data acquisition and control system for Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Zhou Qingguo; Wang Li; Wang Yanlong; Zhao Hong; Zhou Rongjie

    2004-01-01

    A remote data acquisition and control system for Moessbauer spectroscopy based on an embedded computer with the Mini Real-Time Linux operating system is presented. This system can be accessed by an Internet browser or a Java application program, which is designed especially for this purpose. So controlling this system is simple and the interface is user friendly. The components of this system can easily be obtained. So it could be built in most laboratories. We have succeeded in designing and developing this system, as well as using the system at the Key Laboratory for Magnetism and Magnetic Material of Ministry of Education, Lanzhou University, PR China

  3. Current position on software for the automatic data acquisition system

    International Nuclear Information System (INIS)

    1988-01-01

    This report describes the current concepts for software to control the operation of the Automatic Data Acquisition System (ADAS) proposed for the Deaf Smith County, Texas, Exploratory Shaft Facility (ESF). The purpose of this report is to provide conceptual details of how the ADAS software will execute the data acquisition function, and how the software will make collected information available to the test personnel, the Data Management Group (DMG), and other authorized users. It is not intended that this report describe all of the ADAS functions in exact detail, but the concepts included herein will form the basis for the formal ADAS functional requirements definition document. 5 refs., 14 figs

  4. Data acquisition and control system for SMARTEX – C

    Energy Technology Data Exchange (ETDEWEB)

    Yeole, Yogesh Govind, E-mail: yogesh@ipr.res.in [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India); Lachhvani, Lavkesh; Bajpai, Manu; Rathod, Surendrasingh; Kumar, Abhijeet; Sathyanarayana, K.; Pujara, H.D. [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India); Pahari, Sambaran [BARC, Vishakhapatanam, 530 012 Andhra Pradesh (India); Chattopadhyay, Prabal K. [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India)

    2016-11-15

    Highlights: • We have developed control and data acquisition system for Nonneutral Plasma experiment named as SMARTEX – C. • The hardware of the system includes a high current power supply, a trigger circuit, a comparator circuit, a PXI system and a computer. • The software has been developed in LabVIEW{sup ®}. • We have presented the complete time synchronization of the operation of the system. • Results obtained from the equipment has been shown. - Abstract: A PXI based data acquisition system has been developed for Small Aspect Ratio Toroidal Experiment in C – shaped geometry (SMARTEX – C), a device to create and confine non-neutral plasma. The data acquisition system (DAQ) includes PXI based data acquisition cards, communication card, chassis, Optical fiber link, a dedicated computer, a trigger circuit (TC) and a voltage comparator. In this paper, we report the development of a comprehensive code in LabVIEW{sup ®} – 2012 software in order to control the operation of SMARTEX – C as well as to acquire the experimental data from it. The code has been incorporated with features like configuration of card parameters. A hardware based control sequence involving TC has also been developed and integrated with the DAQ. In the acquisition part, the data from an experimental shot is acquired when a digital pulse from one of the PXI cards triggers TC, which further triggers the TF – power supply and rest of the DAQ. The data hence acquired, is stored in the hard disc in binary format for further analysis.

  5. L-C Measurement Acquisition Method for Aerospace Systems

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, B. Douglas; Shams, Qamar A.; Fox, Robert L.

    2003-01-01

    This paper describes a measurement acquisition method for aerospace systems that eliminates the need for sensors to have physical connection to a power source (i.e., no lead wires) or to data acquisition equipment. Furthermore, the method does not require the sensors to be in proximity to any form of acquisition hardware. Multiple sensors can be interrogated using this method. The sensors consist of a capacitor, C(p), whose capacitance changes with changes to a physical property, p, electrically connected to an inductor, L. The method uses an antenna to broadcast electromagnetic energy that electrically excites one or more inductive-capacitive sensors via Faraday induction. This method facilitates measurements that were not previously possible because there was no practical means of providing power and data acquisition electrical connections to a sensor. Unlike traditional sensors, which measure only a single physical property, the manner in which the sensing element is interrogated simultaneously allows measurement of at least two unrelated physical properties (e.g., displacement rate and fluid level) by using each constituent of the L-C element. The key to using the method for aerospace applications is to increase the distance between the L-C elements and interrogating antenna; develop all key components to be non-obtrusive and to develop sensing elements that can easily be implemented. Techniques that have resulted in increased distance between antenna and sensor will be presented. Fluid-level measurements and pressure measurements using the acquisition method are demonstrated in the paper.

  6. On line systems of information acquisition

    International Nuclear Information System (INIS)

    Kucharek, P.; Toth, J.

    2004-01-01

    The modern methods of tracing the real state of working funds and the decisions made on the basis of the portfolio of factors, with the possibility of depicting the results of strategical decisions, enable the companies to compete in the hard environs of the global competition. Common platform providing the total information about dynamics of procedures and production goods in the real time is applied in many power plants of the SE, Plc. The software platform SYSTEM 1 is the subject to the constant development in accordance with the needs of modern management of working fond. The System 1(tm) release 5.0 is expected in the second quarter of 2004. New approach to application package according to users demands will provide higher comfort by using a product. New possibilities will be demonstrated on particular SE, Plc applications. Scenario of determination of potential breakdown of a machine - elements of a machine at the very beginning and the way of support decision on different levels of management. Operation, maintenance, optimization of production and the management of the whole company can decide on the basis of the knowledge and the factors provided in real time and fully by one environs directly on the manager's desk

  7. Data acquisition system and analysis programme for environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    Rajaram, S.; Kannan, V.; Hegde, A.G.

    2003-01-01

    Full text: In every Environmental Survey Laboratory (ESL) many nuclear radiation detecting instruments such as low level Gas Flow Beta Counting Systems, Gross Alpha Counting Systems, Gamma Counting Systems (Single Channel Analyser) are in use to detect the environmental radiation level. These instruments give output in terms of number (total pulse event counts), which is further manually converted into activity concentration per unit weight of the environmental samples. There is considerable difficulty and delay in obtaining the data, since calculations are done manually and also it is very difficult to maintain database of these results for future reference. In order to overcome all this difficulties a Data Acquisition System and Analysing Software Programme has been designed and developed. This paper describes the design and development of the Data Acquisition System using PCL-830 Counter Timer add on card, for networking the environmental radioactivity monitoring equipment's, which is under routine operation at ESL Kalpakkam

  8. A data acquisition system for elementary particle physics

    International Nuclear Information System (INIS)

    Grittenden, J.A.; Benenson, G.; Cunitz, H.; Hsuing, Y.B.; Kaplan, D.M.; Sippach, W.; Stern, B.

    1984-01-01

    The data acquisition system experiment 605 at the Fermi National Accelerator Laboratory employs a set of data transfer protocols developed at Columbia University and implemented in the Nevis Laboratories Data Transport System. The authors describe the logical design of the Transport System, its physical realization, and its particular application during the Spring, 1982 data run of experiment 605. During that run it served as the interface between the data latches and a megabyte of fast memory, operating at a data transfer rate of 200 nsec/16-bit word. Up to two thousand events were read out during the one second beam spill, each event consisting of about 250 words. Included are details of proposed improvements to the data acquisition system and append a brief comment of the need for inexpensive, versatile readout systems in experimental elementary particle physics

  9. An improved data acquisition system at the Saskatchewan Accelerator Laboratory

    International Nuclear Information System (INIS)

    Norum, W.E.

    1994-01-01

    An improved data acquisition system has been in service at the Saskatchewan Accelerator Laboratory for the past 14 months. The system has shown itself to be reliable and easy to use having collected over 800 gigabytes of data for a number of experiments. The system is based on a VME front end computer acquiring data from CAMAC and FASTBUS modules and forwarding the data via an Ethernet connection to an acquisition workstation for archiving and on-line analysis. A multiprocessor real-time operating system in the front end computer makes increasing the performance of the system a simple matter of adding an additional processor to the VME chassis. Experimenters need only write a high-level description of their experiment which is transformed into a C program for the front end computer by a translation program. Special requirements are met by facilities for direct inclusion of user C or FORTRAN code

  10. Autonomous data acquisition system for Paks NPP process noise signals

    International Nuclear Information System (INIS)

    Lipcsei, S.; Kiss, S.; Czibok, T.; Dezso, Z.; Horvath, Cs.

    2005-01-01

    A prototype of a new concept noise diagnostics data acquisition system has been developed recently to renew the aged present system. This new system is capable of collecting the whole available noise signal set simultaneously. Signal plugging and data acquisition are performed by autonomous systems (installed at each reactor unit) that are controlled through the standard plant network from a central computer installed at a suitable location. Experts can use this central unit to process and archive data series downloaded from the reactor units. This central unit also provides selected noise diagnostics information for other departments. The paper describes the hardware and software architecture of the new system in detail, emphasising the potential benefits of the new approach. (author)

  11. Proceedings of the workshop on data acquisition system for high energy physics

    International Nuclear Information System (INIS)

    Hayano, R.S.

    1984-09-01

    The workshop ''Data acquisition system for high energy experiment'' was held by the on-line electronics group of KEK in cooperation with the data processing section on May 28-29, 1984, at KEK. This year, the proton synchrotron is prepared for the work after shutdown, and in the TRISTAN, the full scale construction of the data acquisition system is advanced. One of the large topics was the TKO box proposed by the data acquisition development group of KEK, and its specification is included in this book. This workshop was the meeting with very wide range from front end electronics to large computers. The talks on flash analog/digital converters and latest data communication were held. As a new trial, the wish lists on the future development and support of on-line electronics and others were collected from the participants, and these were deliberated by all the members. The contents of the discussion at this time are given in this book. The summaries of the lectures presented at the meeting are collected in this book. The interchange with the experimental group is indispensable for the activities of the on-line electronics group, accordingly, the workshop like this will be held hereafter. (Kako, I.)

  12. Design and Development of Data Acquisition System Process Parameters of Kartini Reactor

    International Nuclear Information System (INIS)

    Prajitno

    2009-01-01

    Design and development of computer program for data acquisition system of process parameters of the Kartini reactor have been done. System was designed using industrial computer which equipped with electronic module PCL-812PG. The function of computer is to take parameter data of reactor process, processing the data and displaying on the numeric form and bar graphic. Electronics module PCL- 12PG was installed in one of computer slot, functions to convert from analog signal to digital, received digital status signal and produce digital output. The analog signal and digital status got from logarithmic power channel, linear power channel dan three control rod. Result of data acquisition is merged in the form of ASCII characters block, send to the master computer serially with communications protocols RS-232. Computer program which has been developed was tested and used for monitoring Kartini reactor operation and give good performance result. (author)

  13. Data Management and Acquisition System for INAA

    International Nuclear Information System (INIS)

    Donald J. Ondov; John M. Ondov

    1998-01-01

    Instrumental neutron activation analysis (INAA) remains a powerful technique for multielemental trace analysis. In atmospheric aerosol studies, we typically determine 40 elements, including markers of natural and anthropogenic sources, heavy metals, and toxic or nutrient trace elements in aerosol samples. The need for size spectral, spatial, and temporal information requires that hundreds of samples be collected and accurately analyzed. Quality assurance is a primary component of the analytical protocol. The quality of INAA data depends on counting statistics--accurate preparation of standards, positioning of samples above the detector, resolution of interferences, and correction for coincidence effects when counting close to the detector--and on reliable operation of the amplifier and analog-to-digital converters. Furthermore, the analysis of such large numbers of samples by INAA is a complicated endeavor, involving a large number of tasks that, if not recorded or completed properly, can compromise the analysis. To reduce the possibility of operator error in keeping track of a complex array of information and to speed the detection of instrumental faults, we have developed a new analysis protocol and automated sample analysis and management (SAM) software system. The SAM system is a relational database application designed to log data associated with the collection of atmospheric aerosol and associated samples collected with a variety of instruments, assist in choosing samples for analysis by a variety of techniques, schedule irradiation and counting for INAA, interface with the ORTEC Gamma Vision (GV) software, capture the analytical data, calculate elemental masses from activities provided by GV, and prepare first-tier data summaries and manipulations. All the sample and flux monitor counts are initiated through SAM

  14. War-gaming application for future space systems acquisition

    Science.gov (United States)

    Nguyen, Tien M.; Guillen, Andy T.

    2016-05-01

    Recently the U.S. Department of Defense (DOD) released the Defense Innovation Initiative (DII) [1] to focus DOD on five key aspects; Aspect #1: Recruit talented and innovative people, Aspect #2: Reinvigorate war-gaming, Aspect #3: Initiate long-range research and development programs, Aspect #4: Make DOD practices more innovative, and Aspect #5: Advance technology and new operational concepts. Per DII instruction, this paper concentrates on Aspect #2 and Aspect #4 by reinvigorating the war-gaming effort with a focus on an innovative approach for developing the optimum Program and Technical Baselines (PTBs) and their corresponding optimum acquisition strategies for acquiring future space systems. The paper describes a unified approach for applying the war-gaming concept for future DOD acquisition of space systems. The proposed approach includes a Unified Game-based Acquisition Framework (UGAF) and an Advanced Game-Based Mathematical Framework (AGMF) using Bayesian war-gaming engines to optimize PTB solutions and select the corresponding optimum acquisition strategies for acquiring a space system. The framework defines the action space for all players with a complete description of the elements associated with the games, including Department of Defense Acquisition Authority (DAA), stakeholders, warfighters, and potential contractors, War-Gaming Engines (WGEs) played by DAA, WGEs played by Contractor (KTR), and the players' Payoff and Cost functions (PCFs). The AGMF presented here addresses both complete and incomplete information cases. The proposed framework provides a recipe for the DAA and USAF-Space and Missile Systems Center (SMC) to acquire future space systems optimally.

  15. A review of electronic journal acquisition, management, and use in health sciences libraries.

    Science.gov (United States)

    Burrows, Suzetta

    2006-01-01

    The paper describes patterns of electronic journal usage in health sciences libraries during the past decade. The paper presents a case study, documenting the pattern of acquisition, management, and usage at the Louis Calder Memorial Library of the University of Miami Miller School of Medicine. Health sciences journals were early to offer electronic alternatives to print. As a result, health sciences libraries, their patrons, and the public at large were early to embrace the new versions and continue to embrace the significant changes in scholarly communication they enable. Although the patterns of electronic journals among health sciences libraries and other special and academic libraries have similarities, they also have differences. Broad studies of electronic journals in non-health sciences libraries have been published, but a retrospective review of electronic journals in health sciences libraries has not.

  16. A higher level language data acquisition system (III) - the user data acquisition program

    International Nuclear Information System (INIS)

    Finn, J.M.; Gulbranson, R.L.; Huang, T.L.

    1983-01-01

    The nuclear physics group at the University of Illinois has implemented a data acquisition system using modified versions of the Concurrent Pascal and Sequential Pascal languages. The user, a physicist, develops a data acquisition ''operating system'', written in these higher level languages, which is tailored to the planned experiment. The user must include only those system functions which are essential to the task, thus improving efficiency. The user program is constructed from simple modules, mainly consisting of Concurrent Pascal PROCESSes, MONITORs, and CLASSes together with appropriate data type definitions. Entire programs can be put together using ''cut and paste'' techniques. Planned enhancements include the automating of this process. Systems written for the Perkin-Elmer 3220 using this approach can easily exceed 2 kHz data rates for event by event handling; 20 kHz data rates have been achieved by the addition of buffers in the interrupt handling software. These rates have been achieved without the use of special-purpose hardware such as micro-programmed branch drivers. With the addition of such devices even higher data rates should be possible

  17. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  18. The ALS gun electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-01-01

    The ALS Gun Electronics system has been designed to accommodate the gun with a custom made socket and a high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  19. The ALS Gun Electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-05-01

    The ALS Gun Electronics system has been designed to accommodate gun with a custom made socket and high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  20. AGS BOOSTER BEAM POSITION, TUNE, AND LONGITUDINAL PROFILE DATA ACQUISITION SYSTEM

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; SEVERINO, F; SMITH, K.; WILINSKI, M

    2003-01-01

    In this paper we will describe a data acquisition system designed and developed for the AGS Booster. The system was motivated by the need to get high quality beam diagnostics from the AGS Booster. This was accomplished by locating the electronics and digital data acquisition close to the Booster ring, to minimize loss of bandwidth in the original signals. In addition we had to develop the system rapidly and at a low cost. The system consists of a Lecroy digital oscilloscope which is interfaced through a National Instruments LabView(trademark) server application, developed for this project. This allows multiple client applications to time share the scope without interfering with each other. We will present a description of the system design along with example clients that we have implemented

  1. The data acquisition system of the RFX experiment

    International Nuclear Information System (INIS)

    Manduchi, G.; Luchetta, A.; Taliercio, C.; Vitturi, S.

    1999-01-01

    The paper describes the experience gained in the development and maintenance of the data acquisition system for the RFX nuclear fusion experiment. The design of the system core started in 1987 and the system was ready at the beginning of the machine operation in late 1991. Since the early design stage it was clear that a careful definition of the system architecture was crucial for allowing the system to cope with the expected improvement in the hardware performance. Not all the initial design choices proved successful for this purpose. In the paper the (positive or negative) consequences of the main design choices of the system are reported. (orig.)

  2. Standard Hardware Acquisition and Reliability Program's (SHARP's) efforts in incorporating fiber optic interconnects into standard electronic module (SEM) connectors

    Science.gov (United States)

    Riggs, William R.

    1994-05-01

    SHARP is a Navy wide logistics technology development effort aimed at reducing the acquisition costs, support costs, and risks of military electronic weapon systems while increasing the performance capability, reliability, maintainability, and readiness of these systems. Lower life cycle costs for electronic hardware are achieved through technology transition, standardization, and reliability enhancement to improve system affordability and availability as well as enhancing fleet modernization. Advanced technology is transferred into the fleet through hardware specifications for weapon system building blocks of standard electronic modules, standard power systems, and standard electronic systems. The product lines are all defined with respect to their size, weight, I/O, environmental performance, and operational performance. This method of defining the standard is very conducive to inserting new technologies into systems using the standard hardware. This is the approach taken thus far in inserting photonic technologies into SHARP hardware. All of the efforts have been related to module packaging; i.e. interconnects, component packaging, and module developments. Fiber optic interconnects are discussed in this paper.

  3. An integrated, multi-vendor distributed data acquisition system

    International Nuclear Information System (INIS)

    Butner, D.N.; Drlik, M.; Meyer, W.H.; Moller, J.M.; Preckshot, G.G.

    1988-01-01

    A distributed data acquisition system that uses various computer hardware and software is being developed to support magnetic fusion experiments at Lawrence Livermore National Laboratory (LLNL). The experimental sequence of operations is controlled by a supervisory program, which coordinates software running on Digital Equipment Corporation (DEC) VAX computers, Hewlett-Packard (HP) UNIX-based workstations, and HP BASIC desktop computers. An interprocess communication system (IPCS) allows programs to communicate with one another in a standard manner regardless of program location in the network or of operating system and hardware differences. We discuss the design and implementation of this data acquisition system with particular emphasis on the coordination model and the IPCS. 5 refs., 3 figs

  4. Software development for a switch-based data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, A. (Superconducting Super Collider Lab., Dallas, TX (United States)); Black, D.; Walsh, D. (Fermi National Accelerator Lab., Batavia, IL (United States))

    1991-12-01

    We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an integrated systems engineering'' environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

  5. A new data acquisition system for pelletron-LINAC experiments

    International Nuclear Information System (INIS)

    Ramachandran, K.; Chatterjee, A.; Singh, Sudheer; Jha, K.; Joy, Saju; Behere, A.; Goadgoankar, M.D.

    2007-01-01

    The LINAC booster facility coupled with Pelletron accelerator at Mumbai and the plans to have large detector arrays such as Indian National Gamma Array, Charged Particle Array, Neutron Array, BaF 2 etc. pose new challenges to have a Data Acquisition system (DAQ) with a throughput an order of magnitude higher than the present CAMAC system. The major limitation of CAMAC readout is the 1μs/word readout time. A new FERA (Fast Encoding and Readout) data acquisition system developed at BARC for the augmentation of the throughput of CAMAC is a readout bus for the CAMAC ADCs. With this FERA DAQ, it is possible to readout CAMAC ADC's at 150 ns/word. This talk will present the new DAQ system used at BARC-TIFR Pelletron Accelerator facility. (author)

  6. Experiment data acquisition and analysis system. Vol. 1

    International Nuclear Information System (INIS)

    Busch, F.; Croome, D.; Goeringer, H.; Hartmann, V.; Lowsky, J.; Marinescu, D.; Richter, M.; Winkelmann, K.

    1983-08-01

    The Experiment Data Acquisition and Analysis System EDAS was created to acquire and analyze data collected in experiments carried out at the heavy ion accelerator UNILAC. It has been available since 1975 and has become the most frequently used system for evaluating experiments at GSI. EDAS has undergone constant development, and the many enhancements make this completely revised third edition of the EDAS manual necessary. EDAS consists of two sub-systems: GOLDA for experimental data acquisition on PDP-11's and SATAN mainly for off-line analysis in replay mode on large IBM mainframes. The capacity of one IBM 3081 CPU is mainly dedicated to EDAS processing and is almost fully utilized by this application. More than 200 users from GSI as well as from collaborating laboratories and universities use SATAN in more than 100 sessions daily needing 10 to 20 hours of user CPU time. EDAS is designed as an open system. (orig./HSI)

  7. Acquisition Management for System of Systems: Requirement Evolution and Acquisition Strategy Planning

    Science.gov (United States)

    2013-01-29

    of modern portfolio and control theory . The reformulation allows for possible changes in estimated quantities (e.g., due to market shifts in... Portfolio Theory (MPT). Final Report: NPS award N00244-11-1-0003 5 Extending CEM and Markov: Agent-Based Modeling Approach Research conducted in the...integration and acquisition from a robust portfolio theory standpoint. Robust portfolio management methodologies have been widely used by financial

  8. A data acquisition system for silicon microstrip detectors

    International Nuclear Information System (INIS)

    Adriani, O.; Civinini, C.; D'Alessandro, R.; Meschini, M.; Pieri, M.; Castellini, G.

    1998-01-01

    Following initial work on the readout of the L3 silicon microvertex detector, the authors have developed a complete data acquisition system for silicon microstrip detectors for use both in their home institute and at the various test beam facilities at the CERN laboratory. The system uses extensive decoupling schemes allowing a fully floating connection to the detector. This feature has many advantages especially in the readout of the latest double-sided silicon microstrip detectors

  9. Data acquisition system for segmented reactor antineutrino detector

    Czech Academy of Sciences Publication Activity Database

    Hons, Zdeněk; Vlášek, J.

    2017-01-01

    Roč. 12, č. 1 (2017), č. článku P01022. ISSN 1748-0221 R&D Projects: GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : Data acquisition concepts * Detector control systems (detector and experiment monitoring and slow-control system, architecture , hardware, algorithms, databases) * Neutrino detectors Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Nuclear physics Impact factor: 1.220, year: 2016

  10. Object oriented run control for the CEBAF data acquisition system

    International Nuclear Information System (INIS)

    Quarrie, D.R.; Heyes, G.; Jastrzembski, E.; Watson, W.A. III

    1992-01-01

    After an extensive evaluation, the Eiffel object oriented language has been selected for the design and implementation of the run control portion of the CEBAF Data Acquisition System. The OSF/Motif graphical user interface toolkit and Data Views process control system have been incorporated into this framework. in this paper, the authors discuss the evaluation process, the status of the implementation and the lessons learned, particularly in the use of object oriented techniques

  11. Simulation Based Acquisition for NASA's Office of Exploration Systems

    Science.gov (United States)

    Hale, Joe

    2004-01-01

    In January 2004, President George W. Bush unveiled his vision for NASA to advance U.S. scientific, security, and economic interests through a robust space exploration program. This vision includes the goal to extend human presence across the solar system, starting with a human return to the Moon no later than 2020, in preparation for human exploration of Mars and other destinations. In response to this vision, NASA has created the Office of Exploration Systems (OExS) to develop the innovative technologies, knowledge, and infrastructures to explore and support decisions about human exploration destinations, including the development of a new Crew Exploration Vehicle (CEV). Within the OExS organization, NASA is implementing Simulation Based Acquisition (SBA), a robust Modeling & Simulation (M&S) environment integrated across all acquisition phases and programs/teams, to make the realization of the President s vision more certain. Executed properly, SBA will foster better informed, timelier, and more defensible decisions throughout the acquisition life cycle. By doing so, SBA will improve the quality of NASA systems and speed their development, at less cost and risk than would otherwise be the case. SBA is a comprehensive, Enterprise-wide endeavor that necessitates an evolved culture, a revised spiral acquisition process, and an infrastructure of advanced Information Technology (IT) capabilities. SBA encompasses all project phases (from requirements analysis and concept formulation through design, manufacture, training, and operations), professional disciplines, and activities that can benefit from employing SBA capabilities. SBA capabilities include: developing and assessing system concepts and designs; planning manufacturing, assembly, transport, and launch; training crews, maintainers, launch personnel, and controllers; planning and monitoring missions; responding to emergencies by evaluating effects and exploring solutions; and communicating across the OEx

  12. Acquisition (Purchasing of ERP Systems from Organizational Buying Behavior Perspective

    Directory of Open Access Journals (Sweden)

    Tariq Bhatti

    2014-05-01

    Full Text Available Enterprise Resource Planning (ERP systems are becoming a mature infrastructure in many organizations. Organizations purchase these systems to integrate, improve internal business processes, serve their customers better and fulfill their needs. The buying process of these systems is more complicated and it requires a lot more consideration as it can have long term effects and consequences for the organization as well as for its stakeholders. Acquisition (purchasing of ERP systems is a complex behavior for organizations and has a lot to consider, from motives all the way to goals being pursued. Buying organizations consider several components that make up its business entity: like vendors, consumers, competitors, and regulations (Harris, 2013. Importance and relevance should be given to each one of these components as they all play key essential roles in sales organizations and their success. Typical organizations treat the purchasing process as a problem solving situation and rely on consultants or sometimes miss out on systematic buying process and the success factors to be considered vary from technicality, price, risk aversion, reputation, all the way to ethical decisions and legal regulations (Bellizzi, 2009. This research paper describe the current acquisition processes, critical success factors literature and propose integrated ERP systems acquisition model for organizations interested in buying similar systems in future.

  13. The JET fast central acquisition and trigger system

    International Nuclear Information System (INIS)

    Blackler, K.; Edwards, A.W.

    1994-01-01

    This paper describes a new data acquisition system at JET which uses Texas TMS320C40 parallel digital signal processors and the HELIOS parallel operating system to reduce the large amounts of experimental data produced by fast diagnostics. This unified system features a two level trigger system which performs real-time activity detection together with asynchronous event classification and selection. This provides automated data reduction during an experiment. The system's application to future fusion machines which have almost continuous operation is discussed

  14. Diagnostic-management system and test pulse acquisition for WEST plasma measurement system

    International Nuclear Information System (INIS)

    Wojenski, A.; Kasprowicz, G.; Pozniak, K.T.; Byszuk, A.; Juszczyk, B.; Zabolotny, W.; Zienkiewicz, P.; Chernyshova, M.; Czarski, T.; Mazon, D.; Malard, P.

    2014-01-01

    This paper describes current status of electronic, firmware and software development for new plasma measurement system for use in WEST facility. The system allows to perform two dimensional plasma visualization (in time) with spectrum measurement. The analog front-end is connected to Gas Electron Multiplier detector (GEM detector). The system architecture have high data throughput due to use of PCI-Express interface, Gigabit Transceivers and sampling frequency of ADC integrated circuits. The hardware is based on several years of experience in building X-ray spectrometer system for Joint European Torus (JET) facility. Data streaming is done using Artix7 FPGA devices. The system in basic configuration can work with up to 256 channels, while the maximum number of measurement channels is 2048. Advanced firmware for the FPGA is required in order to perform high speed data streaming and analog signal sampling. Diagnostic system management has been developed in order to configure measurement system, perform necessary calibration and prepare hardware for data acquisition. (authors)

  15. An electronic interface for acquisition of 12 delayed gamma-gammacoincidence spectra

    International Nuclear Information System (INIS)

    Domienikan, Claudio

    2001-01-01

    An electronic interface has been constructed to be used m conjunctionwith a Time differential Perturbed gamma-gamma Angular Correlation (TDPAC)spectrometer with four BaF 2 detectors. The routing interface is speciallydesigned to work with the Ortec model ADCAM 920-16 multichannel analyzer(MCA) having 16 multiplexed inputs, permitting the simultaneous acquisitionof 12 delayed gamma-gamma coincidence spectra. This innovation provides aconsiderable reduction in the experimental data acquisition time and as aconsequence permits an improvement in the precision of the final results ofthe hyperfine parameters deduced from the TDPAC measurements. The interfaceconsists of two distinct electronic circuits. A novel high performance analogdemultiplexer circuit is used to address the linear pulses from the time toamplitude converter (TAC) to the corresponding MCA inputs, according to thepair of detectors responsible for the given gamma-gamma coincidence.Validation of the gamma-gamma coincidence and control of the analogdemultiplexer are realized by a digital circuit, consisting basically ofmonostable multivibrators and decoders of High-Speed CMOS Logic (HCT). Theperformance of the routing interface was evaluated through several testmeasurements which included the time resolution and linearity of the system,the quadrupolar interaction in 181 Ta(Hf), 181 Ta(HfO 2 ), 111 Cd(Cd)and 111 Cd(Pd) samples, and the hyperfine magnetic field in 181 'Ta(Ni), 11 '1Cd(Ni) and 140 Ce(Gd) samples. The results of the hyperfineinteraction measurements are discussed and compared with previous results andserve to demonstrate the correct and efficient performance of the constructedinterface. (author)

  16. TELL1 data acquisition system for LHCb detectors

    International Nuclear Information System (INIS)

    Gong Guanghua; Xue Tao; Gong Hui; Shao Beibei

    2004-01-01

    A FPGA based data acquisition readout board has been developed for the LHCb detectors. With optical or analogue daughter cards, it can readout data from several different off-detector electronics. The data synchronization, buffering, pre-processing, zero-suppression and many interfaces to memory chips and communication buses are all implemented by the FPGA in VHDL code. The board sends data out via a 4 channel Gigabit Ethernet adapter. The TELL1 can accepts 24 optical links running at 1.6 GHz and provides for the analogue option 64 10-bit ADC channels sampling at 40 MHz. (authors)

  17. New data acquisition system for the lujan center

    International Nuclear Information System (INIS)

    Nelson, R.; Bowling, P.S.; Cooper, G.M.; Kozlowski, T.

    2001-01-01

    To meet the data acquisition requirements for six new neutron scattering instruments at the Los Alamos Science Center (LANSCE), we are building systems using Web tools, commercial hardware and software, software developed by the controls community, and custom hardware developed by the neutron scattering community. To service these new instruments as well as seven existing instruments, our data acquisition system needs common software and hardware core capabilities and the means to flexibly integrate them while differentiating the needs of the diverse instrument suite. Neutron events are captured and processed in VXI modules while controls for sample environment and beam line setup are processed with PCs. Typically users access the system through web browsers. (author)

  18. Microcomputer-controlled ultrasonic data acquisition system. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, W.A. Jr.

    1978-11-01

    The large volume of ultrasonic data generated by computer-aided test procedures has necessitated the development of a mobile, high-speed data acquisition and storage system. This approach offers the decided advantage of on-site data collection and remote data processing. It also utilizes standard, commercially available ultrasonic instrumentation. This system is controlled by an Intel 8080A microprocessor. The MCS80-SDK microcomputer board was chosen, and magnetic tape is used as the storage medium. A detailed description is provided of both the hardware and software developed to interface the magnetic tape storage subsystem to Biomation 8100 and Biomation 805 waveform recorders. A boxcar integrator acquisition system is also described for use when signal averaging becomes necessary. Both assembly language and machine language listings are provided for the software.

  19. Run control techniques for the Fermilab DART data acquisition system

    International Nuclear Information System (INIS)

    Oleynik, G.; Engelfried, J.; Mengel, L.; Moore, C.; Pordes, R.; Udumula, L.; Votava, M.; Drunen, E. van; Zioulas, G.

    1996-01-01

    DART is the high speed, Unix based data acquisition system being developed by the Fermilab Computing Division in collaboration with eight High Energy Physics Experiments. This paper describes DART run-control which implements flexible, distributed, extensible and portable paradigms for the control monitoring of a data acquisition systems. We discuss the unique and interesting aspects of the run-control - why we chose the concepts we did, the benefits we have seen from the choices we made, as well as our experiences in deploying and supporting it for experiments during their commissioning and sub-system testing phases. We emphasize the software and techniques we believe are extensible to future use, and potential future modifications and extensions for those we feel are not. (author)

  20. Experience from Tore Supra acquisition system and evolutions

    International Nuclear Information System (INIS)

    Guillerminet, B.; Buravand, Y.; Chatelier, E.; Leroux, F.

    2004-01-01

    The Tore Supra tokamak has been upgraded to explore long duration plasma discharges up to 1000s. Since summer 2001, the acquisition system operates in continuous mode apart of the data processing which is still done after the pulse. In the first part, we explore a few solutions to process continuously the data during the pulse, based on parallel processing on a Linux farm and then on a CONDOR system. The second part is devoted to the Web service exposing the Tore Supra operation. In the last part, the VME acquisition system has been redesigned to keep up with the high data rates required by a few diagnostics. The workflow is now distributed among a few computers. At the end, we give the current status of the realisation and the future planning

  1. New data acquisition system for the lujan center

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, R.; Bowling, P.S.; Cooper, G.M.; Kozlowski, T. [Los Alamos National Loboratory, Los Alamos, NM (United States)

    2001-03-01

    To meet the data acquisition requirements for six new neutron scattering instruments at the Los Alamos Science Center (LANSCE), we are building systems using Web tools, commercial hardware and software, software developed by the controls community, and custom hardware developed by the neutron scattering community. To service these new instruments as well as seven existing instruments, our data acquisition system needs common software and hardware core capabilities and the means to flexibly integrate them while differentiating the needs of the diverse instrument suite. Neutron events are captured and processed in VXI modules while controls for sample environment and beam line setup are processed with PCs. Typically users access the system through web browsers. (author)

  2. Proposed data acquisition system for the Fermilab Booster

    International Nuclear Information System (INIS)

    Bharadwaj, V.; Peggs, S.; Wu, G.; Saltmarsh, C.

    1991-01-01

    At present, studies involving the FNAL Booster (or in fact most accelerators) depend on knowing exactly what detector one has to look at and at what time. Because of this, most studies are done 'on-line' and involve looking for repetitive effects using a limited number of detectors. In this paper the authors propose to design a Booster Data Acquisition System (BDAQ) for the FNAL Booster. In essence this system consists of a large number of digitizers with circular memory buffers. After a machine cycle of interest, these buffers are frozen and then read out into a mass storage device. This paper discusses the hardware and software capabilities needed to make such a data acquisition system a powerful tool for doing accelerator physics studies and improving machine performance

  3. Run control techniques for the Fermilab DART data acquisition system

    International Nuclear Information System (INIS)

    Oleynik, G.; Engelfried, J.; Mengel, L.

    1995-10-01

    DART is the high speed, Unix based data acquisition system being developed by the Fermilab Computing Division in collaboration with eight High Energy Physics Experiments. This paper describes DART run-control which implements flexible, distributed, extensible and portable paradigms for the control and monitoring of data acquisition systems. We discuss the unique and interesting aspects of the run-control - why we chose the concepts we did, the benefits we have seen from the choices we made, as well as our experiences in deploying and supporting it for experiments during their commissioning and sub-system testing phases. We emphasize the software and techniques we believe are extensible to future use, and potential future modifications and extensions for those we feel are not

  4. Control and Data Acquisition System of the ATLAS Facility

    International Nuclear Information System (INIS)

    Choi, Ki-Yong; Kwon, Tae-Soon; Cho, Seok; Park, Hyun-Sik; Baek, Won-Pil; Kim, Jung-Taek

    2007-02-01

    This report describes the control and data acquisition system of an integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) facility, which recently has been constructed at KAERI (Korea Atomic Energy Research Institute). The control and data acquisition system of the ATLAS is established with the hybrid distributed control system (DCS) by RTP corp. The ARIDES system on a LINUX platform which is provided by BNF Technology Inc. is used for a control software. The IO signals consists of 1995 channels and they are processed at 10Hz. The Human-Machine-Interface (HMI) consists of 43 processing windows and they are classified according to fluid system. All control devices can be controlled by manual, auto, sequence, group, and table control methods. The monitoring system can display the real time trend or historical data of the selected IO signals on LCD monitors in a graphical form. The data logging system can be started or stopped by operator and the logging frequency can be selected among 0.5, 1, 2, 10Hz. The fluid system of the ATLAS facility consists of several systems including a primary system to auxiliary system. Each fluid system has a control similarity to the prototype plant, APR1400/OPR1000

  5. Impact of CALS on Electronic Publishing Systems and Users.

    Science.gov (United States)

    Beazley, William G.

    1990-01-01

    The U.S. Department of Defense has begun using its buying power to enforce standards on the vendors and contractors of automatic data processing hardware and software. An example of this, the Computer-Aided Acquisition and Logistic Support (CALS) program, is described, and how it will affect electronic publishing systems is discussed. (five…

  6. STRATEGY FOR EVALUATION AND SELECTION OF SYSTEMS FOR ELECTRONIC LEARNING

    OpenAIRE

    Dubravka Mandušić; Lucija Blašković

    2012-01-01

    Today`s technology supported and accelerated learning time requires constant and continuous acquisition of new knowledge. On the other hand, it does not leave enough time for additional education. Increasing number of E-learning systems, withdraws a need for precise evaluation of functionality that those systems provide; so they could be reciprocally compared. While implementing new systems for electronic learning, it is very important to pre-evaluate existing systems in order to ...

  7. A multifunctional data acquisition and processing system based on microcomputer

    International Nuclear Information System (INIS)

    Chen Huaide; Pan Dajing; Zhu Cuiqin

    1988-01-01

    Introduced herein is a multifunctional MCA-computer system which can operate as a foreground and a background with capabilities of high resolution in γ-ray spectrum analysis, multiplex multi-scale, multi-scale, and the display system with resolution being high up to 8192 points. The MCA has 8192 channels with 20 bits and 8k buffer memory. Firstly, the acquisition data is stored into the buffer memory and then transformed into computer for processing. The system software consists of the management software, spectrum processing and multiplex multi-scale measurement software. The block diagram of the system, the specifications and testing results are given

  8. ELECTRONIC FILE MONITORING SYSTEM

    African Journals Online (AJOL)

    GBUBEMI

    2014-11-06

    Nov 6, 2014 ... The result of the developed system shows a simple and effective graphic user interface ... business transactions, decision-making records and storage of .... Start. Input username and password. Access denied was login.

  9. Vessel Electronic Reporting System (VERS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The VERS system is composed of a database and other related applications which facilitate the reporting of electronically collected research data via Fisheries...

  10. A research of a high precision multichannel data acquisition system

    Science.gov (United States)

    Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei

    2013-08-01

    The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.

  11. Multi-channel data acquisition system with absolute time synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Włodarczyk, Przemysław, E-mail: pan.wlodarczyk@uj.edu.pl [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland); Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Pustelny, Szymon, E-mail: pustelny@uj.edu.pl [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Budker, Dmitry [Department of Physics, University of California at Berkeley, Berkeley, California 94720-7300 (United States); Lipiński, Marcin [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland)

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics – GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  12. Multi-channel data acquisition system with absolute time synchronization

    Science.gov (United States)

    Włodarczyk, Przemysław; Pustelny, Szymon; Budker, Dmitry; Lipiński, Marcin

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics - GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  13. Optimal Acquisition and Inventory Control for a Remanufacturing System

    Directory of Open Access Journals (Sweden)

    Zhigang Jiang

    2013-01-01

    Full Text Available Optimal acquisition and inventory control can often make the difference between successful and unsuccessful remanufacturing. However, there is a greater degree of uncertainty and complexity in a remanufacturing system, which leads to a critical need for planning and control models designed to deal with this added uncertainty and complexity. In this paper, a method for optimal acquisition and inventory control of a remanufacturing system is presented. The method considers three inventories, one for returned item and the other for serviceable and recoverable items. Taking the holding cost for returns, recoverable and remanufactured products, remanufacturing cost, disposal cost, and the loss caused by backlog into account, the optimal inventory control model is established to minimize the total costs. Finally, a numerical example is provided to illustrate the proposed methods.

  14. A small Unix-based data acquisition system

    International Nuclear Information System (INIS)

    Engberg, D.; Glanzman, T.

    1993-06-01

    The proposed SLAC B Factory detector plans to use Unix-based machines for all aspects of computing, including real-time data acquisition and experimental control. An R ampersand D program has been established to investigate the use of Unix in the various aspects of experimental computation. Earlier R ampersand D work investigated the basic real-time aspects of the IBM RS/6000 workstation running AIX. The next step in this R ampersand D is the construction of prototype data acquisition system which attempts to exercise many of the features needed in the final on-line system in a realistic situation. For this project, we have combined efforts with a team studying the use of novel cell designs and gas mixtures in a new prototype drift chamber

  15. Automatic Control and Data Acquisition System for Combustion Laboratory Applications.

    Science.gov (United States)

    1982-10-01

    O VPI Access~.ion FCr- 1473 2 UNCLASSIFIED Approved for public release; distribution unlimited JAutomatic Control and Data Acquisition System for...unit. The CPU/ROK board includes a 16 bit microprocessor chip which decodes and executes all in- structions, and controls all data transfers. The 12K...in the limited memory space of 32K of the HP-85 33 ACQDTA’ 1) Controls DevicesCRAIN ,2) Acquires Photodiods Output$ 3) Stores Data o Disc 1

  16. Biomedical image acquisition system using a gamma camera

    International Nuclear Information System (INIS)

    Jara B, A.T.; Sevillano, J.; Del Carpio S, J.A.

    2003-01-01

    A gamma camera images PC acquisition board has been developed. The digital system has been described using VHDL and has been synthesized and implemented in a Altera Max7128S CPLD and two PALs 16L8. The use of programmable-logic technologies has afforded a higher scale integration and a reduction of the digital delays and also has allowed us to modify and bring up to date the entire digital design easily. (orig.)

  17. A simple timestamping data acquisition system for ToF-ERDA

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Mikko, E-mail: mikrossi@jyu.fi; Rahkila, Panu; Kettunen, Heikki; Laitinen, Mikko

    2015-03-15

    A new data acquisition system, ToF-DAQ, has been developed for a ToF-ERDA telescope and other ToF-E and ToF–ToF measurement systems. ToF-DAQ combines an analogue electronics front-end to asynchronous time stamped data acquisition by means of a FPGA device. Coincidences are sought solely in software based on the timestamps. Timestamping offers more options for data analysis as coincidence events can be built also in offline analysis. The system utilizes a National Instruments R-series FPGA device and a Windows PC as a host computer. Both the FPGA code and the host software were developed using the National Instruments LabVIEW graphical programming environment. Up to eight NIM ADCs can be handled by a single FPGA. The host computer and the FPGA can process total continuous count rates of over 750,000 counts/s with a timestamping resolution of 8.33 ns.

  18. A New Acquisition and Imaging System for Environmental Measurements: An Experience on the Italian Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Fabio Leccese

    2014-05-01

    Full Text Available A new acquisition system for remote control of wall paintings has been realized and tested in the field. The system measures temperature and atmospheric pressure in an archeological site where a fresco has been put under control. The measuring chain has been designed to be used in unfavorable environments where neither electric power nor telecommunication infrastructures are available. The environmental parameters obtained from the local monitoring are then transferred remotely allowing an easier management by experts in the field of conservation of cultural heritage. The local acquisition system uses an electronic card based on microcontrollers and sends the data to a central unit realized with a Raspberry-Pi. The latter manages a high quality camera to pick up pictures of the fresco. Finally, to realize the remote control at a site not reached by internet signals, a WiMAX connection based on different communication technologies such as WiMAX, Ethernet, GPRS and Satellite, has been set up.

  19. The JET diagnostic fast central acquisition and trigger system (abstract)

    Science.gov (United States)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  20. The Resource Manager the ATLAS Trigger and Data Acquisition System

    CERN Document Server

    Aleksandrov, Igor; The ATLAS collaboration; Lehmann Miotto, Giovanna; Soloviev, Igor

    2016-01-01

    The Resource Manager of the ATLAS Trigger and Data Acquisition system The Resource Manager is one of the core components of the Data Acquisition system of the ATLAS experiment at the LHC. The Resource Manager marshals the right for applications to access resources which may exist in multiple but limited copies, in order to avoid conflicts due to program faults or operator errors. The access to resources is managed in a manner similar to what a lock manager would do in other software systems. All the available resources and their association to software processes are described in the Data Acquisition configuration database. The Resource Manager is queried about the availability of resources every time an application needs to be started. The Resource Manager’s design is based on a client-server model, hence it consists of two components: the Resource Manager "server" application and the "client" shared library. The Resource Manager server implements all the needed functionalities, while the Resource Manager c...

  1. Isolated data acquisition system for high voltage applications

    International Nuclear Information System (INIS)

    Waitz, A.; Donaldson, A.

    1985-06-01

    This report describes the design and operation of a microcomputer controlled system for acquisition of both analog and binary data within the high voltage stages of a linac modulator. The system is comprised of a microprocessor Controller which communicates with the remote data Acquisition circuits via an optical bus. The bus, which uses a 1 MHz Manchester II format, is configured as a loop, starting at the Controller, daisy-chaining the remote cards and terminating back at the Controller. Upon receiving a linac timing pulse, the Controller sends addressed commands to the individual remote cards and receives data back. It then passes this data to the linac control system through a Multibus connection. Each remote circuit can return 16 binary sense and 7 (12 bit) analog parameters within 270 us. This speed is possible because of a pipelined design where one word is transmitted while another is being converted. A data conversion cycle is initiated when a remote data acquisition card receives the proper command and address from the controller

  2. The scientific data acquisition system of the GAMMA-400 space project

    Science.gov (United States)

    Bobkov, S. G.; Serdin, O. V.; Gorbunov, M. S.; Arkhangelskiy, A. I.; Topchiev, N. P.

    2016-02-01

    The description of scientific data acquisition system (SDAS) designed by SRISA for the GAMMA-400 space project is presented. We consider the problem of different level electronics unification: the set of reliable fault-tolerant integrated circuits fabricated on Silicon-on-Insulator 0.25 mkm CMOS technology and the high-speed interfaces and reliable modules used in the space instruments. The characteristics of reliable fault-tolerant very large scale integration (VLSI) technology designed by SRISA for the developing of computation systems for space applications are considered. The scalable net structure of SDAS based on Serial RapidIO interface including real-time operating system BAGET is described too.

  3. A camac based data acquisition system for flat-panel image array readout

    International Nuclear Information System (INIS)

    Morton, E.J.; Antonuk, L.E.; Berry, J.E.; Huang, W.; Mody, P.; Yorkston, J.; Longo, M.J.

    1993-01-01

    A readout system has been developed to facilitate the digitization and subsequent display of image data from two-dimensional, pixellated, flat-panel, amorphous silicon imaging arrays. These arrays have been designed specifically for medical x-ray imaging applications. The readout system is based on hardware and software developed for various experiments at CERN and Fermi National Accelerator Laboratory. Additional analog signal processing and digital control electronics were constructed specifically for this application. The authors report on the form of the resulting data acquisition system, discuss aspects of its performance, and consider the compromises which were involved in its design

  4. Structure and data presentation in the data acquisition system for the SFINKS device

    International Nuclear Information System (INIS)

    Kul'man, N.Yu.

    1988-01-01

    The aim of the paper is to create a convenient system to describe the data structure coming from the data acquisition electronics. A language to describe the data structure to accordance with the setup detectors which allows one to make changes in the processing system with the changes of the setup configuration has been proposed. The inner presentation is realized in the form of trees in the ZBOOK system, widely used in high energy physics. Events are treated according to the description and are in the ZBOOK banks. The data are written on the tape in the computer-independent EP-format

  5. The Nuclotron internal target control and data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Isupov, A.Yu., E-mail: isupov@moonhe.jinr.ru [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Krasnov, V.A.; Ladygin, V.P.; Piyadin, S.M.; Reznikov, S.G. [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation)

    2013-01-11

    The new control system of the Nuclotron (JINR, Dubna) internal target is described in both hardware and software aspects. The CAMAC hardware is based on the use of the standard CAMAC modules developed and manufactured at JINR. The internal target control and data acquisition (IntTarg CDAQ) system software is implemented using the ngdp framework under the Unix-like operating system (OS) FreeBSD to allow easy network distribution of the online data collected from internal target and accompanying detectors, as well as the internal target remote control.

  6. The design of the Hyperon Data Acquisition System

    International Nuclear Information System (INIS)

    Gee, C.N.P.

    1980-12-01

    A new Native-mode Data Acquisition system, running on a VAX 11/780, has been designed for the SPS Hyperon Experiments at CERN. The system incorporates a variable number of communicating processes running under VAX/VMS, including user-written monitoring processes. Event handling has been implemented into the CAMAC Driver, and facilities are provided for using a data buffer much larger than the System Maximum Working-set Size. A generalised debugging facility for non terminal-oriented processes is also supported. (author)

  7. Advanced electronics for the CTF MEG system.

    Science.gov (United States)

    McCubbin, J; Vrba, J; Spear, P; McKenzie, D; Willis, R; Loewen, R; Robinson, S E; Fife, A A

    2004-11-30

    Development of the CTF MEG system has been advanced with the introduction of a computer processing cluster between the data acquisition electronics and the host computer. The advent of fast processors, memory, and network interfaces has made this innovation feasible for large data streams at high sampling rates. We have implemented tasks including anti-alias filter, sample rate decimation, higher gradient balancing, crosstalk correction, and optional filters with a cluster consisting of 4 dual Intel Xeon processors operating on up to 275 channel MEG systems at 12 kHz sample rate. The architecture is expandable with additional processors to implement advanced processing tasks which may include e.g., continuous head localization/motion correction, optional display filters, coherence calculations, or real time synthetic channels (via beamformer). We also describe an electronics configuration upgrade to provide operator console access to the peripheral interface features such as analog signal and trigger I/O. This allows remote location of the acoustically noisy electronics cabinet and fitting of the cabinet with doors for improved EMI shielding. Finally, we present the latest performance results available for the CTF 275 channel MEG system including an unshielded SEF (median nerve electrical stimulation) measurement enhanced by application of an adaptive beamformer technique (SAM) which allows recognition of the nominal 20-ms response in the unaveraged signal.

  8. Application of tape unit in data acquisition system and its maintenance and trouble shoot

    International Nuclear Information System (INIS)

    Xing Jianping; Qian Xicheng

    1995-01-01

    Application of magnetic tape unit in data acquisition system of DEC computer imported from German and its maintenance as well as trouble shoot is described. The system is used for nuclear data acquisition and processing

  9. Monitoring and Acquisition Real-time System (MARS)

    Science.gov (United States)

    Holland, Corbin

    2013-01-01

    MARS is a graphical user interface (GUI) written in MATLAB and Java, allowing the user to configure and control the Scalable Parallel Architecture for Real-Time Acquisition and Analysis (SPARTAA) data acquisition system. SPARTAA not only acquires data, but also allows for complex algorithms to be applied to the acquired data in real time. The MARS client allows the user to set up and configure all settings regarding the data channels attached to the system, as well as have complete control over starting and stopping data acquisition. It provides a unique "Test" programming environment, allowing the user to create tests consisting of a series of alarms, each of which contains any number of data channels. Each alarm is configured with a particular algorithm, determining the type of processing that will be applied on each data channel and tested against a defined threshold. Tests can be uploaded to SPARTAA, thereby teaching it how to process the data. The uniqueness of MARS is in its capability to be adaptable easily to many test configurations. MARS sends and receives protocols via TCP/IP, which allows for quick integration into almost any test environment. The use of MATLAB and Java as the programming languages allows for developers to integrate the software across multiple operating platforms.

  10. Architecture of SPIDER control and data acquisition system

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Taliercio, C.; Soppelsa, A.; Barbalace, A.; Paolucci, F.; Sartori, F.; Barbato, P.; Breda, M.; Capobianco, R.; Molon, F.; Moressa, M.; Polato, S.; Simionato, P.; Zampiva, E.

    2012-01-01

    The ITER Heating Neutral Beam injectors will be implemented in three steps: development of the ion source prototype, development of the full injector prototype, and, finally, construction of up to three ITER injectors. The first two steps will be carried out in the ITER neutral beam test facility under construction in Italy. The ion source prototype, referred to as SPIDER, which is currently in the development phase, is a complex experiment involving more than 20 plant units and operating with beam-on pulses lasting up to 1 h. As for control and data acquisition it requires fast and slow control (cycle time around 0.1 ms and 10 ms, respectively), synchronization (10 ns resolution), and data acquisition for about 1000 channels (analogue and images) with sampling frequencies up to tens of MS/s, data throughput up to 200 MB/s, and data storage volume of up to tens of TB/year. The paper describes the architecture of the SPIDER control and data acquisition system, discussing the SPIDER requirements and the ITER CODAC interfaces and specifications for plant system instrumentation and control.

  11. Mobile real-time data acquisition system for application in preventive medicine.

    Science.gov (United States)

    Neubert, Sebastian; Arndt, Dagmar; Thurow, Kerstin; Stoll, Regina

    2010-05-01

    In this article, the development of a system for online monitoring of a subject's physiological parameters and subjective workload regardless of location has been presented, which allows for studies on occupational health. In the sector of occupational health, modern acquisition systems are needed. Such systems can be used by the subject during usual daily routines without being influenced by the presence of an examiner. Moreover, the system's influence on the subject should be reduced to a minimum to receive reliable data from the examination. The acquisition system is based on a mobile handheld (or smart phone), which allows both management of the communication process and input of several dialog data (e.g., questionnaires). A sensor electronics module permits the acquisition of different physiological parameters and their online transmission to the handheld via Bluetooth. The mobile handheld and the sensor electronics module constitute a wireless personal area network. The handheld allows the first analysis, the synchronization of the data, and the continuous data transfer to a communication server by the integrated mobile radio standards of the handheld. The communication server stores the incoming data of several subjects in an application-dependent database and allows access from all over the world via a Web-based management system. The developed system permits one examiner to monitor the physiological parameters and the subjective workload of several subjects in different locations at the same time. Thereby the subjects can move almost freely in any area covered by the mobile network. The mobile handheld allows the popping-up of the questionnaires at flexible time intervals. This electronic input of the dialog data, in comparison to the manual documentation on papers, is more comfortable to the subject as well as to the examiner for an analysis. A Web-based management application facilitates a continuous remote monitoring of the physiological and the

  12. System design description for mini-dacs data acquisition and control system

    International Nuclear Information System (INIS)

    Vargo, F.G. Jr.; Trujillo, L.T.; Smith, S.O.

    1994-01-01

    This document describes the hardware computer system, for the mini data acquisition and control system (DACS) that was fabricated by Los Alamos National Laboratory (LANL), to support the testing of the spare mixer pump for SY-101

  13. Component reliability for electronic systems

    CERN Document Server

    Bajenescu, Titu-Marius I

    2010-01-01

    The main reason for the premature breakdown of today's electronic products (computers, cars, tools, appliances, etc.) is the failure of the components used to build these products. Today professionals are looking for effective ways to minimize the degradation of electronic components to help ensure longer-lasting, more technically sound products and systems. This practical book offers engineers specific guidance on how to design more reliable components and build more reliable electronic systems. Professionals learn how to optimize a virtual component prototype, accurately monitor product reliability during the entire production process, and add the burn-in and selection procedures that are the most appropriate for the intended applications. Moreover, the book helps system designers ensure that all components are correctly applied, margins are adequate, wear-out failure modes are prevented during the expected duration of life, and system interfaces cannot lead to failure.

  14. Fundamentals of electronic systems design

    CERN Document Server

    Lienig, Jens

    2017-01-01

    This textbook covers the design of electronic systems from the ground up, from drawing and CAD essentials to recycling requirements. Chapter by chapter, it deals with the challenges any modern system designer faces: the design process and its fundamentals, such as technical drawings and CAD, electronic system levels, assembly and packaging issues and appliance protection classes, reliability analysis, thermal management and cooling, electromagnetic compatibility (EMC), all the way to recycling requirements and environmental-friendly design principles. Enables readers to face various challenges of designing electronic systems, including coverage from various engineering disciplines; Written to be accessible to readers of varying backgrounds; Uses illustrations extensively to reinforce fundamental concepts; Organized to follow essential design process, although chapters are self-contained and can be read in any order.

  15. 77 FR 70708 - VA Acquisition Regulation: Electronic Submission of Payment Requests

    Science.gov (United States)

    2012-11-27

    ... electronic data interchange (EDI) formats; or (3) another electronic form as prescribed by the contract....fsc.va.gov/einvoice.asp .); or, (b) A system that conforms to the X12 electronic data interchange (EDI... Institute (ANSI). The X12 EDI Web site ( http://www.x12.org ) includes additional information on EDI 810 and...

  16. Analytical purpose electron backscattering system

    International Nuclear Information System (INIS)

    Desdin, L.; Padron, I.; Laria, J.

    1996-01-01

    In this work an analytical purposes electron backscattering system improved at the Center of Applied Studies for Nuclear Development is described. This system can be applied for fast, exact and nondestructive testing of binary and AL/Cu, AL/Ni in alloys and for other applications

  17. The PAUCam readout electronics system

    Science.gov (United States)

    Jiménez, Jorge; Illa, José M.; Cardiel-Sas, Laia; de Vicente, Juan; Castilla, Javier; Casas, Ricard

    2016-08-01

    The PAUCam is an optical camera with a wide field of view of 1 deg x 1 deg and up to 46 narrow and broad band filters. The camera is already installed on the William Herschel Telescope (WHT) in the Canary Islands, Spain and successfully commissioned during the first period of 2015. The paper presents the main results from the readout electronics commissioning tests and include an overview of the whole readout electronics system, its configuration and current performance.

  18. Proposed data acquisition system for an associated particle neutron generator and a LYSO gamma detector

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Kwang Pyo; Sim, Cheul Muu; Em, V. T.; Lee, Seung Wook; Kim, Young Jin [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Park, Seong Yong; Park, Jin; Kim, Hee Jung [Kyungwon Enterprise, Seoul (Korea, Republic of)

    2005-07-01

    A data acquisition system has been designed that deals with essentially two signals: a sharp timing pulse (with a width of roughly 20 nanoseconds) from a Hamamatsu H6568 square photomultiplier tube utilizing a 16-pixel ZnO(Ga) phosphor-coated alpha particle detector, and a long energy pulse (with a falltime of roughly 200 microseconds) from a LYSO detector designed for extreme precision in measuring the energy of gamma rays. These two detectors have been selected because they exhibit ideal characteristics for the ultimate goal of this system: detection and identification of drugs, explosives, and chemical warfare agents at a comparably very high rate of speed while maintaining reliable decision-making capacity. The entire data acquisition Will be designed and each component Will be specified with a commercially-available electronic module utilizing a VME bus or high speed CAMAC.

  19. Method for signal conditioning and data acquisition system, based on variable amplification and feedback technique

    Energy Technology Data Exchange (ETDEWEB)

    Conti, Livio, E-mail: livio.conti@uninettunouniversity.net [Facoltà di Ingegneria, Università Telematica Internazionale Uninettuno, Corso Vittorio Emanuele II 39, 00186 Rome, Italy INFN Sezione Roma Tor Vergata, Via della Ricerca Scientifica 1, 00133 Rome (Italy); Sgrigna, Vittorio [Dipartimento di Matematica e Fisica, Università Roma Tre, 84 Via della Vasca Navale, I-00146 Rome (Italy); Zilpimiani, David [National Institute of Geophysics, Georgian Academy of Sciences, 1 M. Alexidze St., 009 Tbilisi, Georgia (United States); Assante, Dario [Facoltà di Ingegneria, Università Telematica Internazionale Uninettuno, Corso Vittorio Emanuele II 39, 00186 Rome, Italy INFN Sezione Roma Tor Vergata, Via della Ricerca Scientifica 1, 00133 Rome (Italy)

    2014-08-21

    An original method of signal conditioning and adaptive amplification is proposed for data acquisition systems of analog signals, conceived to obtain a high resolution spectrum of any input signal. The procedure is based on a feedback scheme of the signal amplification with aim at maximizing the dynamic range and resolution of the data acquisition system. The paper describes the signal conditioning, digitization, and data processing procedures applied to an a priori unknown signal in order to enucleate its amplitude and frequency content for applications in different environments: on the ground, in space, or in the laboratory. An electronic board of the conditioning module has also been constructed and described. In the paper are also discussed the main fields of application and advantages of the method with respect to those known today.

  20. Method for signal conditioning and data acquisition system, based on variable amplification and feedback technique

    International Nuclear Information System (INIS)

    Conti, Livio; Sgrigna, Vittorio; Zilpimiani, David; Assante, Dario

    2014-01-01

    An original method of signal conditioning and adaptive amplification is proposed for data acquisition systems of analog signals, conceived to obtain a high resolution spectrum of any input signal. The procedure is based on a feedback scheme of the signal amplification with aim at maximizing the dynamic range and resolution of the data acquisition system. The paper describes the signal conditioning, digitization, and data processing procedures applied to an a priori unknown signal in order to enucleate its amplitude and frequency content for applications in different environments: on the ground, in space, or in the laboratory. An electronic board of the conditioning module has also been constructed and described. In the paper are also discussed the main fields of application and advantages of the method with respect to those known today

  1. The Tara control, monitoring, data acquisition, and analysis system

    International Nuclear Information System (INIS)

    Sullivan, J.D.; Gaudreau, M.P.J.; Blanter, B.

    1987-01-01

    Experiments at the MIT Tara Tandem Mirror utilize an integrated system for control, monitoring, data acquisition, physics analysis, and archiving. This system consists of two distinct parts with narrowly defined information interchange; one to provide automated control and real time monitoring of engineering functions and one to acquire, analyze, and display data for physics in near real time. Typical machine operation achieves a total cycle time of 3 to 8 minutes with 5 to 7 Mbytes of data stored and with --160 individual signals displayed in hardcopy on --10 pages

  2. Multifunctional data acquisition system based on USB and FPGA

    International Nuclear Information System (INIS)

    Huang Tuchen; Gong Hui; Shao Beibei

    2013-01-01

    A multifunctional data acquisition system based on USB and FPGA was developed. The system has four analog inputs digitalized by fast ADC. Based on flexibility of FPGA, different functions can be implemented such as waveform sampling, pulse counting, multi-channel pulse height analysis, and charge division readout process. The hardware communicates with host PC via USB interface. The Labview based user soft ware initializes the hardware, configures the running parameters, reads and processes the data as well as displays the result online. (authors)

  3. Integrated systems for real time data acquisition and processing

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.

    1995-01-01

    The continuous measuring of all the nuclear and dosimetric parameters in a nuclear facility is essential for personnel and environment protection. Considering the vast amount of information and data required to keep an updated overview of a situation the need for an efficient acquisition processing and information system is evident. The paper analyses the special requirements as concerning the real time inter-process communication and proposes a modern concept based on the last trends existing in the field of computer technology and operating systems. (author)

  4. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  5. The Tara control, monitoring, data acquisition and analysis system

    International Nuclear Information System (INIS)

    Sullivan, J.D.; Gaudreau, M.P.J.; Blanter, B.

    1986-09-01

    Experiments at the MIT Tara Tandem Mirror utilize an integrated system for control, monitoring, data acquisition, physics analysis, and archiving. This system consists of two distinct parts with narrowly defined information interchange; one to provide automated control and real time monitoring of engineering functions and one to acquire, analyze, and display data for physics in near real time. Typical machine operation achieves a total cycle time of 3 to 8 minutes with 5 to 7 Mbytes of data stored and with ∼160 individual signals displayed in hardcopy on ∼10 pages

  6. IPNS distributed-processing data-acquisition system

    International Nuclear Information System (INIS)

    Haumann, J.R.; Daly, R.T.; Worlton, T.G.; Crawford, R.K.

    1981-01-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a major new user-oriented facility which has come on line for basic research in neutron scattering and neutron radiation damage. This paper describes the distributed-processing data-acquisition system which handles data collection and instrument control for the time-of-flight neutron-scattering instruments. The topics covered include the overall system configuration, each of the computer subsystems, communication protocols linking each computer subsystem, and an overview of the software which has been developed

  7. Data acquisition system for medium power neutral beam test facility

    International Nuclear Information System (INIS)

    Stewart, C.R. Jr.; Francis, J.E. Jr.; Hammons, C.E.; Dagenhart, W.K.

    1978-06-01

    The Medium Power Neutral Beam Test Facility at Oak Ridge National Laboratory was constructed in order to develop, test, and condition powerful neutral beam lines for the Princeton Large Torus experiment at Princeton Plasma Physics Laboratory. The data acquisition system for the test stand monitors source performance, beam characteristics, and power deposition profiles to determine if the beam line is operating up to its design specifications. The speed of the computer system is utilized to provide near-real-time analysis of experimental data. Analysis of the data is presented as numerical tabulation and graphic display

  8. Data acquisition system for PLT Neutral Beam Test Stand

    International Nuclear Information System (INIS)

    Francis, J.E. Jr.; Hammons, C.E.

    1977-01-01

    The PLT Neutral Beam Test Stand at Oak Ridge National Laboratory was constructed to test and condition powerful neutral beam sources for the Princeton Large Torus experiment at Princeton Plasma Physics Laboratory. The data acquisition system for the test stand monitors the beam characteristics and power output to determine if the beam is operating at its design specifications. The high speed of the computer system is utilized to provide near-real-time analysis of experimental data. The analysis of the data is presented as numerical tabulation and graphic display

  9. Wearable System for Acquisition and Monitoring of Biological Signals

    Science.gov (United States)

    Piccinini, D. J.; Andino, N. B.; Ponce, S. D.; Roberti, MA; López, y. N.

    2016-04-01

    This paper presents a modular, wearable system for acquisition and wireless transmission of biological signals. Configurable slaves for different signals (such as ECG, EMG, inertial sensors, and temperature) based in the ADS1294 Medical Analog Front End are connected to a Master, based in the CC3200 microcontroller, both from Texas Instruments. The slaves are configurable according to the specific application, providing versatility to the wearable system. The battery consumption is reduced, through a couple of Li-ion batteries and the circuit has also a battery charger. A custom made box was designed and fabricated in a 3D printer, preserving the requirements of low cost, low weight and safety recommendations.

  10. Study on data acquisition system based on reconfigurable cache technology

    Science.gov (United States)

    Zhang, Qinchuan; Li, Min; Jiang, Jun

    2018-03-01

    Waveform capture rate is one of the key features of digital acquisition systems, which represents the waveform processing capability of the system in a unit time. The higher the waveform capture rate is, the larger the chance to capture elusive events is and the more reliable the test result is. First, this paper analyzes the impact of several factors on the waveform capture rate of the system, then the novel technology based on reconfigurable cache is further proposed to optimize system architecture, and the simulation results show that the signal-to-noise ratio of signal, capacity, and structure of cache have significant effects on the waveform capture rate. Finally, the technology is demonstrated by the engineering practice, and the results show that the waveform capture rate of the system is improved substantially without significant increase of system's cost, and the technology proposed has a broad application prospect.

  11. Low cost open data acquisition system for biomedical applications

    Science.gov (United States)

    Zabolotny, Wojciech M.; Laniewski-Wollk, Przemyslaw; Zaworski, Wojciech

    2005-09-01

    In the biomedical applications it is often necessary to collect measurement data from different devices. It is relatively easy, if the devices are equipped with a MIB or Ethernet interface, however often they feature only the asynchronous serial link, and sometimes the measured values are available only as the analog signals. The system presented in the paper is a low cost alternative to commercially available data acquisition systems. The hardware and software architecture of the system is fully open, so it is possible to customize it for particular needs. The presented system offers various possibilities to connect it to the computer based data processing unit - e.g. using the USB or Ethernet ports. Both interfaces allow also to use many such systems in parallel to increase amount of serial and analog inputs. The open source software used in the system makes possible to process the acquired data with standard tools like MATLAB, Scilab or Octave, or with a dedicated, user supplied application.

  12. Design of remote laser-induced fluorescence system's acquisition circuit

    Science.gov (United States)

    Wang, Guoqing; Lou, Yue; Wang, Ran; Yan, Debao; Li, Xin; Zhao, Xin; Chen, Dong; Zhao, Qi

    2017-10-01

    Laser-induced fluorescence system(LIfS) has been found its significant application in identifying one kind of substance from another by its properties even it's thimbleful, and becomes useful in plenty of fields. Many superior works have reported LIfS' theoretical analysis , designs and uses. However, the usual LIPS is always constructed in labs to detect matter quite closely, for the system using low-power laser as excitation source and charge coupled device (CCD) as detector. Promoting the detectivity of LIfS is of much concern to spread its application. Here, we take a high-energy narrow-pulse laser instead of commonly used continuous wave laser to operate sample, thus we can get strong fluorescent. Besides, photomultiplier (PMT) with high sensitivity is adopted in our system to detect extremely weak fluorescence after a long flight time from the sample to the detector. Another advantage in our system, as the fluorescence collected into spectroscopy, multiple wavelengths of light can be converted to the corresponding electrical signals with the linear array multichannel PMT. Therefore, at the cost of high-powered incentive and high-sensitive detector, a remote LIFS is get. In order to run this system, it is of importance to turn light signal to digital signal which can be processed by computer. The pulse width of fluorescence is deeply associated with excitation laser, at the nanosecond(ns) level, which has a high demand for acquisition circuit. We design an acquisition circuit including, I/V conversion circuit, amplifying circuit and peak-holding circuit. The simulation of circuit shows that peak-holding circuit can be one effective approach to reducing difficulty of acquisition circuit.

  13. The research of data acquisition system for Raman spectrometer

    Science.gov (United States)

    Cui, Xiao; Guo, Pan; Zhang, Yinchao; Chen, Siying; Chen, He; Chen, Wenbo

    2011-11-01

    Raman spectrometer has been widely used as an identification tool for analyzing material structure and composition in many fields. However, Raman scattering echo signal is very weak, about dozens of photons at most in one laser plus signal. Therefore, it is a great challenge to design a Raman spectrum data acquisition system which could accurately receive the weak echo signal. The system designed in this paper receives optical signals with the principle of photon counter and could detect single photon. The whole system consists of a photoelectric conversion module H7421-40 and a photo counting card including a field programmable gate array (FPGA) chip and a PCI9054 chip. The module H7421-40 including a PMT, an amplifier and a discriminator has high sensitivity on wavelength from 300nm to 720nm. The Center Wavelength is 580nm which is close to the excitation wavelength (532nm), QE 40% at peak wavelength, Count Sensitivity is 7.8*105(S-1PW-1) and Count Linearity is 1.5MHZ. In FPGA chip, the functions are divided into three parts: parameter setting module, controlling module, data collection and storage module. All the commands, parameters and data are transmitted between FPGA and computer by PCI9054 chip through the PCI interface. The result of experiment shows that the Raman spectrum data acquisition system is reasonable and efficient. There are three primary advantages of the data acquisition system: the first one is the high sensitivity with single photon detection capability; the second one is the high integrated level which means all the operation could be done by the photo counting card; and the last one is the high expansion ability because of the smart reconfigurability of FPGA chip.

  14. PXIe based data acquisition and control system for ECRH systems on SST-1 and Aditya tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Jatinkumar J., E-mail: jatin@ipr.res.in [Institute for Plasma Research, Bhat, Gandhinagar (India); Shukla, B.K.; Rajanbabu, N.; Patel, H.; Dhorajiya, P.; Purohit, D. [Institute for Plasma Research, Bhat, Gandhinagar (India); Mankadiya, K. [Optimized Solutions Pvt. Ltd (India)

    2016-11-15

    Highlights: • Data Aquisition and control system (DAQ). • PXIe hardware–(PXI–PCI bus extension for Instrumention Express). • RHVPS–Regulated High Voltage Power supply. • SST1–Steady state superconducting tokamak. - Abstract: In Steady State Superconducting (SST-1) tokamak, various RF heating sub-systems are used for plasma heating experiments. In SST-1, Two Electron Cyclotron Resonance Heating (ECRH) systems have been installed for pre-ionization, heating and current drive experiments. The 42 GHz gyrotron based ECRH system is installed and in operation with SST-1 plasma experiments. The 82.6 GHz gyrotron delivers 200 kW CW power (1000 s) while the 42 GHz gyrotron delivers 500 kW power for 500 ms duration. Each gyrotron system consists of various auxiliary power supplies, the crowbar unit and the water cooling system. The PXIe (PCI bus extension for Instrumentation Express)bus based DAC (Data Acquisition and Control) system has been designed, developed and under implementation for safe and reliable operation of the gyrotron. The Control and Monitoring Software applications have been developed using NI LabView 2014 software with real time support on windows platform.

  15. PXIe based data acquisition and control system for ECRH systems on SST-1 and Aditya tokamak

    International Nuclear Information System (INIS)

    Patel, Jatinkumar J.; Shukla, B.K.; Rajanbabu, N.; Patel, H.; Dhorajiya, P.; Purohit, D.; Mankadiya, K.

    2016-01-01

    Highlights: • Data Aquisition and control system (DAQ). • PXIe hardware–(PXI–PCI bus extension for Instrumention Express). • RHVPS–Regulated High Voltage Power supply. • SST1–Steady state superconducting tokamak. - Abstract: In Steady State Superconducting (SST-1) tokamak, various RF heating sub-systems are used for plasma heating experiments. In SST-1, Two Electron Cyclotron Resonance Heating (ECRH) systems have been installed for pre-ionization, heating and current drive experiments. The 42 GHz gyrotron based ECRH system is installed and in operation with SST-1 plasma experiments. The 82.6 GHz gyrotron delivers 200 kW CW power (1000 s) while the 42 GHz gyrotron delivers 500 kW power for 500 ms duration. Each gyrotron system consists of various auxiliary power supplies, the crowbar unit and the water cooling system. The PXIe (PCI bus extension for Instrumentation Express)bus based DAC (Data Acquisition and Control) system has been designed, developed and under implementation for safe and reliable operation of the gyrotron. The Control and Monitoring Software applications have been developed using NI LabView 2014 software with real time support on windows platform.

  16. Low cost method for manufacturing a data acquisition system with USB connectivity

    Science.gov (United States)

    Niculescu, V.; Dobre, R. A.; Popovici, E.

    2016-06-01

    In the process of designing and manufacturing an electronic system the digital oscilloscope plays an essential role but it also represents one of the most expensive equipment present on the typical workbench. In order to make electronic design more accessible to students and hobbyists, an affordable data acquisition system was imagined. The paper extensively presents the development and testing of a low cost, medium speed, data acquisition system which can be used in a wide range of electronic measurement and debugging applications, assuring also great portability due to the small physical dimensions. Each hardware functional block and is thoroughly described, highlighting the challenges that occurred as well as the solutions to overcome them. The entire system was successfully manufactured using high quality components to assure increased reliability, and high frequency PCB materials and techniques were preferred. The measured values determined based on test signals were compared to the ones obtained using a digital oscilloscope available on the market and differences less than 1% were observed.

  17. Design and implementation of a data acquisition system for the study of dynamics signals in the time Domain

    International Nuclear Information System (INIS)

    Daza, Arnoldo; Hinojosa, Ana; Diaz, Xavier; Neira, Oscar

    2011-01-01

    The purpose of this research was to design and implement a data acquisition system for the study of dynamic signals in the time in order of nanoseconds, through the use of electronic instrumentation to obtain the temporal profiles of light signals, such as pulses of light from a laser or fluorescent light signals. To carry out the design and implementation of the data acquisition system proposed, we used a rapid response transducer and a data acquisition card of high speed. As well, it was developed a graphical user interface for visualization, analysis and study of the data acquired. Thus, it was possible to perform the digitization of a pulse on the order of nanoseconds, as well as the acquisition of fluorescence signals of different wavelengths, from which to obtain theoretical and experimental valuable knowledge based on the physics of spectroscopy.

  18. Spent fuel test. Climax data acquisition system integration report

    International Nuclear Information System (INIS)

    Nyholm, R.A.; Brough, W.G.; Rector, N.L.

    1982-06-01

    The Spent Fuel Test - Climax (SFT-C) is a test of the retrievable, deep geologic storage of commercially generated, spent nuclear reactor fuel in granitic rock. Eleven spent fuel assemblies, together with 6 electrical simulators and 20 guard heaters, are emplaced 420 m below the surface in the Climax granite at the Nevada Test Site. On June 2, 1978, Lawrence Livermore National Laboratory (LLNL) secured funding for the SFT-C, and completed spent fuel emplacement May 28, 1980. This multi-year duration test is located in a remote area and is unattended much of the time. An extensive array of radiological safety and geotechnical instrumentation is deployed to monitor the test performance. A dual minicomputer-based data acquisition system collects and processes data from more than 900 analog instruments. This report documents the design and functions of the hardware and software elements of the Data Acquisition System and describes the supporting facilities which include environmental enclosures, heating/air-conditioning/humidity systems, power distribution systems, fire suppression systems, remote terminal stations, telephone/modem communications, and workshop areas. 9 figures

  19. Microprocessor based data acquisition system for Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Patwardhan, P.K.; Indurkar, V.S.

    1981-01-01

    A data acquisition system, for Moessbauer spectrometer and other probability distribution spectrum is described. This utilizes the advantages of incorporating a microcomputer for providing a flexible analytical capability and speed of hard wired MCS unit updating channel contents in DMA. Holbourn, Player and Woodhams have recently described a microprocessor controlled Moessbauer spectrometer where microprocessor performs the task of updating channel contents, requiring about 60 micro seconds in interrupt mode. This imposes restrictions on increasing the channel number and on increasing the velocity scan frequency in order to cover higher velocity ranges. The system described in this article performs data acquisition in faster direct memory access. It is a two module system, (1) MCS module (2) Microcomputer module, arranged around a common address, data and control buses. The microcomputer module has an access to the system data during flyback periods and can be programmed for the task of monitor on progess of experiment and as a manipulator of various control operations needed during experiment. The system firmware includes: (1) MONITOR (2) BLOCK-TRANSFER (3) DATA-SMOOTHING (4) DECIMAL-CONVERTER (5) MATH. The scope of this firmware is briefly described. (author)

  20. Quality cost system in electronics

    International Nuclear Information System (INIS)

    Denzer, H.O.

    1978-01-01

    A description is presented of a formal cost of quality system used in an electronic manufacturing facility. The system elements and reports are illustrated. Examples of the use of a quality cost system to measure quality performance and to improve product quality are included. A comparison to industry averages for quality costs is made. The paper attempts to show that the collection and use of quality costs are an aid to management and can be accompanied by improved product quality

  1. A High-Performance VME-Based Acquisition System for Positron Emission Mammography

    International Nuclear Information System (INIS)

    Abbott, D.J.; Weisenberger, A.; Majewski, S.; Kieper, D.; Kross, B.; Popov, V.; Wojcik, R.; Raylman, R.R.

    2001-01-01

    A prototype for a practical and economical breast imaging system for cancer detection is currently under development at Jefferson Lab. The latest advances in bright, fast, crystal scintillators, compact position-sensitive photomultipliers (PSPMT), and high-performance digitizing and readout electronics are being used to develop a compact imager based on Positron Emission Tomography (PET). To facilitate the performance demands of the detector as well as the high number of readout channels, the data acquisition system is built around an intelligent, self-contained, VME form-factor

  2. Development of an operator's mental model acquisition system. 1. Estimation of a physical mental model acquisition system

    International Nuclear Information System (INIS)

    Ikeda, Mitsuru; Mizoguchi, Riichirou; Yoshikawa, Shinji; Ozawa, Kenji

    1997-03-01

    This report describes a technical survey of acquisition method of an operator's understanding for functions and structures of his target nuclear plant. This method is to play a key role in the information processing framework to support on-training operators in forming their knowledge of the nuclear plants. This kind of technical framework is aiming at enhancing human operator's ability to cope with anomaly plant situations which are difficult to expect from preceding experiences or engineering surveillance. In these cases, cause identifications and responding operation selections are desired to made not only empirically but also based on thoughts about possible phenomena to take place within the nuclear plant. This report focuses on a particular element technique, defined as 'explanation-based knowledge acquisition', as the candidate technique to potentially be extended to meet the requirement written above, and discusses about applicability to the learning support system and about necessary improvements, to identify future technical developments. (author)

  3. Development of an operator`s mental model acquisition system. 1. Estimation of a physical mental model acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Mitsuru; Mizoguchi, Riichirou [Inst. of Scientific and Industrial Research, Osaka Univ., Ibaraki (Japan); Yoshikawa, Shinji; Ozawa, Kenji

    1997-03-01

    This report describes a technical survey of acquisition method of an operator`s understanding for functions and structures of his target nuclear plant. This method is to play a key role in the information processing framework to support on-training operators in forming their knowledge of the nuclear plants. This kind of technical framework is aiming at enhancing human operator`s ability to cope with anomaly plant situations which are difficult to expect from preceding experiences or engineering surveillance. In these cases, cause identifications and responding operation selections are desired to made not only empirically but also based on thoughts about possible phenomena to take place within the nuclear plant. This report focuses on a particular element technique, defined as `explanation-based knowledge acquisition`, as the candidate technique to potentially be extended to meet the requirement written above, and discusses about applicability to the learning support system and about necessary improvements, to identify future technical developments. (author)

  4. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  5. Magnetic-Field-Response Measurement-Acquisition System

    Science.gov (United States)

    Woodward, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.

    2006-01-01

    A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a

  6. Integrated knowledge base tool for acquisition and verification of NPP alarm systems

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Seong, Poong Hyun

    1998-01-01

    Knowledge acquisition and knowledge base verification are important activities in developing knowledge-based systems such as alarm processing systems. In this work, we developed the integrated tool, for knowledge acquisition and verification of NPP alarm processing systems, by using G2 tool. The tool integrates document analysis method and ECPN matrix analysis method, for knowledge acquisition and knowledge verification, respectively. This tool enables knowledge engineers to perform their tasks from knowledge acquisition to knowledge verification consistently

  7. A multi-channel microcomputer data acquisition system

    International Nuclear Information System (INIS)

    Loureiro, J.S.

    1987-01-01

    A data acquisition system was developed in order to transfer automatically to a 64 kb microcomputer the data generated by a nuclear spectroscopy system in a multichannel analyser. The data in the memory are stored in a floppy disk and will be further used as data entry for any spectrum analysis program, eliminating the tedious work of manually digitizing the spectrum and the possible mistakes associated with it. The developed system connected a POLYMAX 201 DP microcomputer, under CP/M operational system, to a NUCLEAR DATA MODEL ND-65 multichannel analyser and was planned for either local spectrum analysis in the microcomputer using a simplified program, or remote analysis in a mainframe using the sophisticated analysis program SAMPO. With the present system, the time spent between printing out of the 4096 channels with the multichannel analyser printer and its corresponding introduction in the analysis program has been reduced from about 6 hours to less than 2 minutes. (author)

  8. The ATLAS Data Acquisition System LHC Run 2

    CERN Document Server

    Panduro Vazquez, William; The ATLAS collaboration

    2016-01-01

    The LHC has been providing pp collisions with record luminosity and energy since the start of Run 2 in 2015. In the ATLAS experiment the Trigger and Data Acquisition system has been upgraded to deal with the increased event rates. The dataflow element of the system is distributed across hardware and software and is responsible for buffering and transporting event data from the Readout system to the High Level Trigger and on to event storage. The dataflow system has been reshaped in order benefit from technological progress and to maximize the flexibility and efficiency of the data selection process. The updated dataflow system is radically different from the previous implementation both in terms of architecture and performance. The previous two level software filtering architecture, known as L2 and the Event Filter, have been merged with the Event Builder function into a single process, performing incremental data collection and analysis. This design has many advantages, among which are: radical simplificatio...

  9. Work of plant data acquisition system for 'MONJU'

    International Nuclear Information System (INIS)

    Hashimoto, Daisuke; Komatsu, Keiichi; Eguchi, Kenji; Morizono, Koji

    2007-01-01

    The fast breeder reactor 'MONJU' (hereafter 'MONJU') is equipped with the system called 'MONJU Integrated Data Acquisition System (MIDAS)' to effectively acquire, accumulate and analyze relevant real-plant process data gathered from the system start-up test. At present, 'MONJU' has been suspended due to a sodium leak accident that occurred in 1995. However, the main part of remodeling construction to prevent sodium leaks was completed in May, 2007 and 'MONJU' is highly expected to resume its operations, stepping into the practical testing phase. In this situation, 'MIDAS' has been replaced with an upgraded version before the system start-up test was resumed. This paper describes overview of the new 'MIDAS' system. (author)

  10. Fibre optic control for electron gun power supplies and data acquisition of 3 MeV DC accelerator

    International Nuclear Information System (INIS)

    Chavan, R.B.; Yadav, Vivek; Dixit, K.P.; Bakhtsingh, R.I.; Rajan, Rehim; Nanu, K.; Mittal, K.C.; Chakravarthy, D.P.; Gantayet, L.M.

    2011-01-01

    A 3 MeV, 10 mA DC Industrial Electron Beam Accelerator is being commissioned at Electron Beam Centre, Navi Mumbai. The electron beam is generated by a triode electron gun and injected into the accelerating column at 5 keV. The gun and its power supplies, (5 kV anode, 3 kV grid and 15V/20A filament), are floating at 3 Million volts, and are situated in a tank which is pressurized with SF6 at 6 kg/cm 2 . These power supplies are required to be controlled remotely. The various accelerator parameters like Beam Energy, Beam Current, RF Electrode Voltage, Power Oscillator Plate Voltage / Current and Vacuum are required to be monitored during beam operation. The software was developed in VB.Net for control and data acquisition. The database is provided in SQL 2005 for storing the data. For this purpose, control system using ADAM modules and Optical fibre has been designed and developed. This paper describes the design features of the control system and experience of use of control software during initial beam trials. (author)

  11. Value-informed space systems design and acquisition

    Science.gov (United States)

    Brathwaite, Joy

    Investments in space systems are substantial, indivisible, and irreversible, characteristics that make them high-risk, especially when coupled with an uncertain demand environment. Traditional approaches to system design and acquisition, derived from a performance- or cost-centric mindset, incorporate little information about the spacecraft in relation to its environment and its value to its stakeholders. These traditional approaches, while appropriate in stable environments, are ill-suited for the current, distinctly uncertain, and rapidly changing technical and economic conditions; as such, they have to be revisited and adapted to the present context. This thesis proposes that in uncertain environments, decision-making with respect to space system design and acquisition should be value-based, or at a minimum value-informed. This research advances the value-centric paradigm by providing the theoretical basis, foundational frameworks, and supporting analytical tools for value assessment of priced and unpriced space systems. For priced systems, stochastic models of the market environment and financial models of stakeholder preferences are developed and integrated with a spacecraft-sizing tool to assess the system's net present value. The analytical framework is applied to a case study of a communications satellite, with market, financial, and technical data obtained from the satellite operator, Intelsat. The case study investigates the implications of the value-centric versus the cost-centric design and acquisition choices. Results identify the ways in which value-optimal spacecraft design choices are contingent on both technical and market conditions, and that larger spacecraft for example, which reap economies of scale benefits, as reflected by their decreasing cost-per-transponder, are not always the best (most valuable) choices. Market conditions and technical constraints for which convergence occurs between design choices under a cost-centric and a value

  12. Development Of Data Acquisition Software For Centralized Radiation Monitoring System

    International Nuclear Information System (INIS)

    Nolida Yussup; Maslina Mohd Ibrahim; Mohd Fauzi Haris; Syirrazie Che Soh; Harzawardi Hasim; Azraf Azman; Mohd Ashhar Khalid

    2014-01-01

    Nowadays, with the growth of technology, many devices and equipment's can be connected to the network and internet to enable online data acquisition. Centralized radiation monitoring system utilizes a Local Area Network (LAN) as a communication media for data acquisition of the area radiation levels from radiation detectors in Malaysian Nuclear Agency (Nuclear Malaysia). The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software development on the system server that is responsible to acquire and record the area radiation readings from the detectors. Then the recorded readings are called in a web programming to be displayed on a web site. The readings with the time stamp are stored in the system database for query. Besides acquiring the area radiation levels in Nuclear Malaysia centrally, additional features such as data conversion from mR to μSv and line chart display are developed in the software for effective radiation level trend observation and studies. (author)

  13. Floating data acquisition system for microwave calorimeter measurements on MTX

    International Nuclear Information System (INIS)

    Sewall, N.R.

    1989-01-01

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 Series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs

  14. Floating data acquisition system for microwave calorimeter measurements on MTX

    International Nuclear Information System (INIS)

    Sewall, N.R.; Meassick, S.

    1989-01-01

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs

  15. The reliability data acquisition system in PWR nuclear power plants

    International Nuclear Information System (INIS)

    Lienart, P.

    1984-01-01

    In April 1978, Electricite de France put a reliability data acquisition system (SRDF) into operation at its two nuclear power plant sites: Fessenheim and Bugey. In the light of the experience acquired and the advantages offered by such a data bank, this system has been progressively extended since 1982 to cover the entire PWR network. The SRDF was originally designed for the follow-up of 4000 items of equipment per pair of units. However, the various difficulties encountered in gathering data made it necessary - in order to safeguard the quality of the information - to reduce this number initially to 800 major mechanical or electromechanical items of equipment designed to ensure the safety or availability of the units. Subsequently, an increase to 1100 was possible. The SRDF consists of a centralized information bank linked by telephone to the various nuclear sites. The software enables the data-acquisition cards to be introduced, modified or deleted. Any user can gain access to the bank by simply making queries in real time. The quality of the acquisition and processing of the data depend on a list of equipment confined to essential operational systems and on a card design combining, as far as possible, the precision and accessibility of the data. A method of logical failure analysis has also been devised, its main purposes being to provide the following: (1) aid to card instruction; (2) an easier way of checking the uniformity of information concerning a failure; and (3) compatibility between the instructions and analysis of data, thereby facilitating development of the data-processing program. (author)

  16. Data acquisition system for light-ion irradiation creep experiment

    International Nuclear Information System (INIS)

    Hendrick, P.L.; Whitaker, T.J.

    1979-07-01

    Software was developed for a PDP11V/03-based data acquisition system to support the Light-Ion Irradiation Creep Experiment installed at the University of Washington Tandem Van de Graaff Accelerator. The software consists of a real-time data acquisition and storage program, DAC04, written in assembly language. This program provides for the acquisition of up to 30 chennels at 100 Hz, data averaging before storage on disk, alarming, data table display, and automatic disk switching. All analog data are acquired via an analog-to-digital converter subsystem having a resolution of 14 bits, a maximum throughput of 20 kHz, and an overall system accuracy of +-0.01%. These specifications are considered essential for the long-term measurement of irradiation creep strains and temperatures during the light-ion bombardment of irradiation creep specimens. The software package developed also contains a collection of FORTRAN programs designed to monitor a test while in progress. These programs use the foreground/background feature of the RT-11 operating system. The background programs provide a variety of services. The program, GRAFTR, allows transient data (i.e., prior to averaging) to be graphed at the graphics terminal. The program, GRAFAV, allows averaged data to be read from disk and displayed graphically at the terminal. The program, TYPAV, reads averaged data from disk and displays it at the terminal in tabular form. Other programs allow text messages to be written to disk, read from disk, and allow access to DAC04 initialization data. 5 figures, 18 tables

  17. FTU bolometer electronic system upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Pollastrone, Fabio, E-mail: fabio.pollastrone@enea.it [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Neri, Carlo; Florean, Marco; Ciccone, Giovanni [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy)

    2013-10-15

    Highlights: ► Design and realization of a new bolometer electronic system. ► Many improvements over the actual commercial system. ► Architecture based on digital electronic hardware with minimal analog front end. ► Auto off-set correction, real time visualization features and small system size. ► Test results for the electronic system. -- Abstract: The FTU (Frascati Tokamak Upgrade) requires a bolometer diagnostic in order to measure the total plasma radiation. The current diagnostic architecture is based on a full analog multichannel AC bolometer system, which uses a carrier frequency amplifier with a synchronous demodulation. Taking into account the technological upgrades in the field of electronics, it was decided to realize an upgrade for the bolometric electronic system by using a hybrid analog/digital implementation. The new system developed at the ENEA Frascati laboratories has many improvements, and mainly a massive system volume reduction, a good measurement linearity and a simplified use. The new hardware system consists of two subsystems: the Bolometer Digital Control and the Bolometer Analog System. The Bolometer Digital Control can control 16 bolometer bridges through the Bolometer Analog System. The Bolometer Digital Control, based on the FPGA architecture, is connected via Ethernet with a PC; therefore, it can receive commands settings from the PC and send the stream of bolometric measurements in real time to the PC. In order to solve the cross-talk between the bridges and the cables, each of the four bridges in the bolometer head receives a different synthesized excitation frequency. Since the system is fully controlled by a PC GUI (Graphic User Interface), it is very user friendly. Moreover, some useful features have been developed, such as: auto off-set correction, bridge amplitude regulation, software gain setting, real time visualization, frequency excitation selection and noise spectrum analyzer embedded function. In this paper, the

  18. LOFT data acquisition and visual display system (DAVDS) presentation program

    International Nuclear Information System (INIS)

    Bullock, M.G.; Miyasaki, F.S.

    1976-03-01

    The Data Acquisition and Visual Display System (DAVDS) at the Loss-of-Fluid Test Facility (LOFT) has 742 data channel recording capability of which 576 are recorded digitally. The purpose of this computer program is to graphically present the data acquired and/or processed by the LOFT DAVDS. This program takes specially created plot data buffers of up to 1024 words and generates time history plots on the system electrostatic printer-plotter. The data can be extracted from two system input devices: Magnetic disk or digital magnetic tape. Versatility has been designed in the program by providing the user three methods of scaling plots: Automatic, control record, and manual. Time required to produce a plot on the system electrostatic printer-plotter varies from 30 to 90 seconds depending on the options selected. The basic computer and program details are described

  19. Increasing the information acquisition volume in iris recognition systems.

    Science.gov (United States)

    Barwick, D Shane

    2008-09-10

    A significant hurdle for the widespread adoption of iris recognition in security applications is that the typically small imaging volume for eye placement results in systems that are not user friendly. Separable cubic phase plates at the lens pupil have been shown to ameliorate this disadvantage by increasing the depth of field. However, these phase masks have limitations on how efficiently they can capture the information-bearing spatial frequencies in iris images. The performance gains in information acquisition that can be achieved by more general, nonseparable phase masks is demonstrated. A detailed design method is presented, and simulations using representative designs allow for performance comparisons.

  20. The D0 level three data acquisition system

    International Nuclear Information System (INIS)

    Chapin, D.

    2004-01-01

    The DZERO experiment located at Fermilab has recently started RunII with an upgraded detector. The RunII physics program requires the Data Acquisition to readout the detector at a rate of 1 KHz. Events fragments, totaling 250 KB, are readout from approximately 60 front end crates and sent to a particular farm node for Level 3 Trigger processing. A scalable system, capable of complex event routing, has been designed and implemented based on commodity components: VMIC 7750 Single Board Computers for readout, a Cisco 6509 switch for data flow, and close to 100 Linux-based PCs for high-level event filtering