WorldWideScience

Sample records for electron-ion multiple coincidence

  1. A new apparatus for electron-ion multiple coincidence momentum imaging spectroscopy

    International Nuclear Information System (INIS)

    Morishita, Y.; Kato, M.; Pruemper, G.; Liu, X.-J.; Lischke, T.; Ueda, K.; Tamenori, Y.; Oura, M.; Yamaoka, H.; Suzuki, I.H.; Saito, N.

    2006-01-01

    We have developed a new experimental apparatus for the electron-ion multiple coincidence momentum imaging spectroscopy in order to obtain the angular distributions of vibration-resolved photoelectrons from molecules fixed in space. The apparatus consists of a four-stage molecular supersonic jet and a spectrometer analyzing three-dimensional momenta of fragment ions and electrons in coincidence

  2. Development of an electron electron ion coincidence analyzer for Auger photoelectron coincidence spectroscopy (APECS) and electron ion coincidence (EICO) spectroscopy

    International Nuclear Information System (INIS)

    Kakiuchi, Takuhiro; Kobayashi, Eiichi; Okada, Naoyuki; Oyamada, Ken; Okusawa, Makoto; Okudaira, Koji K.; Mase, Kazuhiko

    2007-01-01

    We have developed an electron electron ion coincidence (EEICO) analyzer for Auger photoelectron coincidence spectroscopy (APECS) and electron ion coincidence (EICO) spectroscopy. It consists of a coaxially symmetric mirror electron energy analyzer (coASMA), a miniature cylindrical mirror electron energy analyzer (CMA), a miniature time-of-flight ion mass spectrometer (TOF-MS), a xyz stage, a tilt-adjustment mechanism, and a conflat flange with an outer diameter of 203 mm. A sample surface is irradiated by synchrotron radiation, and emitted electrons are energy-analyzed and detected by the coASMA and the CMA, while desorbed ions are detected by the TOF-MS. The performance of the new EEICO analyzer was tested by measuring Si-LVV-Si-2p APECS data of clean Si(1 1 1)7 x 7 and Si(1 1 1)7 x 7 covered by dissociated H 2 O, and by measuring the Auger-electron photoion coincidence (AEPICO) spectra of condensed H 2 O at the 4a 1 <- O 1s resonance

  3. Development of an Apparatus for High-Resolution Auger Photoelectron Coincidence Spectroscopy (APECS) and Electron Ion Coincidence (EICO) Spectroscopy

    Science.gov (United States)

    Kakiuchi, Takuhiro; Hashimoto, Shogo; Fujita, Narihiko; Mase, Kazuhiko; Tanaka, Masatoshi; Okusawa, Makoto

    We have developed an electron electron ion coincidence (EEICO) apparatus for high-resolution Auger photoelectron coincidence spectroscopy (APECS) and electron ion coincidence (EICO) spectroscopy. It consists of a coaxially symmetric mirror electron energy analyzer (ASMA), a miniature double-pass cylindrical mirror electron energy analyzer (DP-CMA), a miniature time-of-flight ion mass spectrometer (TOF-MS), a magnetic shield, an xyz stage, a tilt-adjustment mechanism, and a conflat flange with an outer diameter of 203 mm. A sample surface was irradiated by synchrotron radiation, and emitted electrons were energy-analyzed and detected by the ASMA and the DP-CMA, while desorbed ions were mass-analyzed and detected by the TOF-MS. The performance of the new EEICO analyzer was evaluated by measuring Si 2p photoelectron spectra of clean Si(001)-2×1 and Si(111)-7×7, and by measuring Si-L23VV-Si-2p Auger photoelectron coincidence spectra (Si-L23VV-Si-2p APECS) of clean Si(001)-2×1.

  4. High mass-resolution electron-ion-ion coincidence measurements on core-excited organic molecules

    CERN Document Server

    Tokushima, T; Senba, Y; Yoshida, H; Hiraya, A

    2001-01-01

    Total electron-ion-ion coincidence measurements on core excited organic molecules have been carried out with high mass resolution by using multimode (reflectron/linear) time-of-flight mass analyzer. From the ion correlation spectra of core excited CH sub 3 OH and CD sub 3 OH, the reaction pathway to form H sub 3 sup + (D sub 3 sup +) is identified as the elimination of three H (D) atoms from the methyl group, not as the inter-group (-CH sub 3 and -OH) interactions. In a PEPIPICO spectrum of acetylacetone (CH sub 3 COCH sub 2 COCH sub 3) measured by using a reflectron TOF, correlations between ions up to mass number 70 with one-mass resolution was recorded.

  5. Wavelength dependent photoelectron circular dichroism of limonene studied by femtosecond multiphoton laser ionization and electron-ion coincidence imaging

    Science.gov (United States)

    Rafiee Fanood, Mohammad M.; Janssen, Maurice H. M.; Powis, Ivan

    2016-09-01

    Enantiomers of the monoterpene limonene have been investigated by (2 + 1) resonance enhanced multiphoton ionization and photoelectron circular dichroism employing tuneable, circularly polarized femtosecond laser pulses. Electron imaging detection provides 3D momentum measurement while electron-ion coincidence detection can be used to mass-tag individual electrons. Additional filtering, by accepting only parent ion tagged electrons, can be then used to provide discrimination against higher energy dissociative ionization mechanisms where more than three photons are absorbed to better delineate the two photon resonant, one photon ionization pathway. The promotion of different vibrational levels and, tentatively, different electronic ion core configurations in the intermediate Rydberg states can be achieved with different laser excitation wavelengths (420 nm, 412 nm, and 392 nm), in turn producing different state distributions in the resulting cations. Strong chiral asymmetries in the lab frame photoelectron angular distributions are quantified, and a comparison made with a single photon (synchrotron radiation) measurement at an equivalent photon energy.

  6. Multiplicity sorter for shift-register coincidence electronics

    International Nuclear Information System (INIS)

    Swansen, J.E.; Collinsworth, P.R.; Krick, M.S.; Peterson, D.L.

    1982-02-01

    A multiplicity sorter for the latest Los Alamos National Laboratory version of shift-register coincidence electronics is described. The multiplicity information taken from the coincidence-gate up-down counter is decoded and gated onto the output lines by prompt real-plus-accidental (R+A) and delayed accidental (A) strobes. Multiplicities of 0-7 and greater than or equal to 8 are sorted for both the R+A and A gates

  7. VUV photoionization of acetamide studied by electron/ion coincidence spectroscopy in the 8-24 eV photon energy range

    KAUST Repository

    Schwell, Martin

    2012-01-01

    A VUV photoionization study of acetamide was carried out over the 8-24 eV photon energy range using synchrotron radiation and photoelectron/photoion coincidence (PEPICO) spectroscopy. Threshold photoelectron photoion coincidence (TPEPICO) measurements were also made. Photoion yield curves and branching ratios were measured for the parent ion and six fragment ions. The adiabatic ionization energy of acetamide was determined as I.E. (1 2A′) = (9.71 ± 0.02) eV, in agreement with an earlier reported photoionization mass spectrometry (PIMS) value. The adiabatic energy of the first excited state of the ion, 1 2A″, was determined to be ≈10.1 eV. Assignments of the fragment ions and the pathways of their formation by dissociative photoionization were made. The neutral species lost in the principal dissociative photoionization processes are CH 3, NH 2, NH 3, CO, HCCO and NH 2CO. Heats of formation are derived for all ions detected and are compared with literature values. Some astrophysical implications of these results are discussed. © 2011 Elsevier B.V. All rights reserved.

  8. Association of autoimmune hepatitis and multiple sclerosis: a coincidence?

    Directory of Open Access Journals (Sweden)

    Marta Sofia Mendes Oliveira

    2015-09-01

    Full Text Available Autoimmune hepatitis is a chronic liver inflammation resulting from deregulation of immune tolerance mechanisms. Multiple sclerosis is also an inflammatory disease in which the insulating covers of nerve cells in the brain and spinal cord are damaged. Here we present a case of an 18 year old female with multiple sclerosis was treated with glatiramer acetate and with interferon beta 1a at our hospital. Seven months after initiating treatment, liver dysfunction occurred. Clinical and laboratory findings were suggestive of drug-induced hepatitis, which led to discontinuation of treatment with interferon. Facing a new episode of acute hepatitis one year later, she was subjected to a liver biopsy, and the analysis of autoantibodies was positive for smooth muscle antibodies. Given the diagnosis of autoimmune hepatitis she started therapy with prednisolone and azathioprine, with good clinical and analytical response. Besides, the demyelinating lesions of multiple sclerosis became lower. In conclusion, there are only a few cases that describe the association of autoimmune hepatitis with multiple sclerosis, and there is a chance both diseases have the same autoimmune inflammatory origin.

  9. Theoretical analysis of the multiple resonances for many-level spin systems. The four-level spin system of s electron ions subjected to strong microwave fields

    International Nuclear Information System (INIS)

    Popescu, F.F.; Marica, F.

    1994-01-01

    The analytic steady state solutions of master equation for the density matrix of a multilevel spin system in dilute paramagnetic crystals at high temperature, subjected to strong microwave fields, are discussed. These solutions enable to obtain the populations of the levels, and the microwave powers absorbed or emitted by the crystal, in the presence of one, two or more microwave fields. A detailed theoretical study of the maser effects for s electron ions with nuclear spin one-half is carried out. In the case of three frequency correlated strong fields, when 'the spectroscopic' bridge conditions are fulfilled, sensitive detections, or high efficient generations of microwaves of frequency higher than those of the pumping fields are predicted. (author) 16 figs., 16 refs

  10. Correction for variable moderation and multiplication effects associated with thermal neutron coincidence counting

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    A correction is described for multiplication and moderation when doing passive thermal neutron coincidence counting nondestructive assay measurements on powder samples of PuO 2 mixed arbitrarily with MgO, SiO 2 , and moderating material. The multiplication correction expression is shown to be approximately separable into the product of two independent terms; F/sub Pu/ which depends on the mass of 240 Pu, and F/sub αn/ which depends on properties of the matrix material. Necessary assumptions for separability are (1) isotopic abundances are constant, and (2) fission cross sections are independent of incident neutron energy: both of which are reasonable for the 8% 240 Pu powder samples considered here. Furthermore since all prompt fission neutrons are expected to have nearly the same energy distributions, variations among different samples can be due only to the moderating properties of the samples. Relative energy distributions are provided by a thermal neutron well counter having two concentric rings of 3 He proportional counters placed symmetrically about the well. Measured outer-to-inner ring ratios raised to an empirically determined power for coincidences, (N/sup I//N/sup O/)/sup Z/, and singles, (T/sup O//T/sup I/)/sup delta/, provide corrections for moderation and F/sub αn/ respectively, and F/sub Pu/ is approximated by M 240 /sup X//M 240 . The exponents are calibration constants determined by a least squares fitting procedure using standards' data. System calibration is greatly simplified using the separability principle. Once appropriate models are established for F/sub Pu/ and F/sub αn/, only a few standards are necessary to determine the calibration constants associated with these terms. Since F/sub Pu/ is expressed as a function of M 240 , correction for multiplication in a subsequent assay demands only a measurement of F/sub αn/

  11. Spectroscopy of heavy few-electron ions

    International Nuclear Information System (INIS)

    Mokler, P.H.

    1986-07-01

    In this paper we ask first, why is it interesting to investigate heavy-few electron ions. Then the various accelerator-based methods to produce heavy few-electron ions are discussed. In the main part an overview on available heavy few-electron ion data and current experiments is given. The summary will end up with future aspects in this field. (orig.)

  12. Using anisotropies in prompt fission neutron coincidences to assess the neutron multiplication of highly multiplying subcritical plutonium assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, J.M., E-mail: jonathan_mueller@ncsu.edu; Mattingly, J.

    2016-07-21

    There is a significant and well-known anisotropy between the prompt neutrons emitted from a single fission event; these neutrons are most likely to be observed at angles near 0° or 180° relative to each other. However, the propagation of this anisotropy through different generations of a fission chain reaction has not been previously studied. We have measured this anisotropy in neutron–neutron coincidences from a subcritical highly-multiplying assembly of plutonium metal. The assembly was a 4.5 kg α-phase plutonium metal sphere composed of 94% {sup 239}Pu and 6% {sup 240}Pu by mass. Data were collected using two EJ-309 liquid scintillators and two EJ-299 plastic scintillators. The angular distribution of neutron–neutron coincidences was measured at 90° and 180° and found to be largely isotropic. Simulations were performed using MCNPX-PoliMi of similar plutonium metal spheres of varying sizes and a correlation between the neutron multiplication of the assembly and the anisotropy of neutron–neutron coincidences was observed. In principle, this correlation could be used to assess the neutron multiplication of an unknown assembly.

  13. Using anisotropies in prompt fission neutron coincidences to assess the neutron multiplication of highly multiplying subcritical plutonium assemblies

    Science.gov (United States)

    Mueller, J. M.; Mattingly, J.

    2016-07-01

    There is a significant and well-known anisotropy between the prompt neutrons emitted from a single fission event; these neutrons are most likely to be observed at angles near 0° or 180° relative to each other. However, the propagation of this anisotropy through different generations of a fission chain reaction has not been previously studied. We have measured this anisotropy in neutron-neutron coincidences from a subcritical highly-multiplying assembly of plutonium metal. The assembly was a 4.5 kg α-phase plutonium metal sphere composed of 94% 239Pu and 6% 240Pu by mass. Data were collected using two EJ-309 liquid scintillators and two EJ-299 plastic scintillators. The angular distribution of neutron-neutron coincidences was measured at 90° and 180° and found to be largely isotropic. Simulations were performed using MCNPX-PoliMi of similar plutonium metal spheres of varying sizes and a correlation between the neutron multiplication of the assembly and the anisotropy of neutron-neutron coincidences was observed. In principle, this correlation could be used to assess the neutron multiplication of an unknown assembly.

  14. Multiple capture investigated by coincident electron spectroscopy in X{sup 7+}+Ar, at 70 keV

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A. [Universite Paul Sabatier, Toulouse (France). Lab. Collisions-Agregats-Reactivite

    1999-11-01

    The multiple electron capture in N{sup 7+} + Ar and F{sup 7+}(1s{sup 2}) + Ar systems is investigated at 70 keV with a new electron-recoil ion charge coincidence experiment. The whole electron energy range has been studied. Up to six electrons are found to be captured into autoionizing states. The recoil ion charge distribution associated with the emission of electrons is similar for both systems and found to be in good agreement with the prediction of Niehaus`s model roughly adapted to take into account autoionizing cascades. New findings for the coincident double and triple captures are briefly discussed. A capture of an inner L-shell electron of Ar into the K-shell of the projectile is also observed in N{sup 7+} + Ar collisions. (orig.) 10 refs.

  15. Severe oxidative damage in multiple sclerosis lesions coincides with enhanced antioxidant enzyme expression.

    NARCIS (Netherlands)

    Horssen, J. van; Schreibelt, G.; Drexhage, J.; Hazes, T.; Dijkstra, C.D.; Valk, P. van de; Vries, H.E. de

    2008-01-01

    Reactive oxygen species (ROS) and subsequent oxidative damage may contribute to the formation and persistence of multiple sclerosis (MS) lesions by acting on distinct pathological processes. ROS initiate lesion formation by inducing blood-brain barrier disruption, enhance leukocyte migration and

  16. Severe oxidative damage in multiple sclerosis lesions coincides with enhanced antioxidant enzyme expression

    NARCIS (Netherlands)

    van Horssen, J.; Schreibelt, G.; Drexhage, J.; Hazes, T.; Dijkstra, C.D.; van der Valk, P.; de Vries, H.E.

    2008-01-01

    Reactive oxygen species (ROS) and subsequent oxidative damage may contribute to the formation and persistence of multiple sclerosis (MS) lesions by acting on distinct pathological processes. ROS initiate lesion formation by inducing blood-brain barrier disruption, enhance leukocyte migration and

  17. Indirect processes in electron-ion scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bottcher, C.; Griffin, D.C.; Pindzola, M.S.; Phaneuf, R.A.

    1983-10-01

    A summary is given of an informal workshop held at Oak Ridge National Laboratory on June 22-23, 1983, in which the current status of theoretical calculations of indirect processes in electron-ion scattering was reviewed. Processes of particular interest in astrophysical and fusion plasmas were emphasized. Topics discussed include atomic structure effects, electron-impact ionization, and dielectronic recombination.

  18. Imaging photoelectron circular dichroism of chiral molecules by femtosecond multiphoton coincidence detection

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, C. Stefan; Ram, N. Bhargava; Janssen, Maurice H. M., E-mail: m.h.m.janssen@vu.nl [LaserLaB Amsterdam, VU University Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands); Powis, Ivan [School of Chemistry, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2013-12-21

    Here, we provide a detailed account of novel experiments employing electron-ion coincidence imaging to discriminate chiral molecules. The full three-dimensional angular scattering distribution of electrons is measured after photoexcitation with either left or right circular polarized light. The experiment is performed using a simplified photoelectron-photoion coincidence imaging setup employing only a single particle imaging detector. Results are reported applying this technique to enantiomers of the chiral molecule camphor after three-photon ionization by circularly polarized femtosecond laser pulses at 400 nm and 380 nm. The electron-ion coincidence imaging provides the photoelectron spectrum of mass-selected ions that are observed in the time-of-flight mass spectra. The coincident photoelectron spectra of the parent camphor ion and the various fragment ions are the same, so it can be concluded that fragmentation of camphor happens after ionization. We discuss the forward-backward asymmetry in the photoelectron angular distribution which is expressed in Legendre polynomials with moments up to order six. Furthermore, we present a method, similar to one-photon electron circular dichroism, to quantify the strength of the chiral electron asymmetry in a single parameter. The circular dichroism in the photoelectron angular distribution of camphor is measured to be 8% at 400 nm. The electron circular dichroism using femtosecond multiphoton excitation is of opposite sign and about 60% larger than the electron dichroism observed before in near-threshold one-photon ionization with synchrotron excitation. We interpret our multiphoton ionization as being resonant at the two-photon level with the 3s and 3p Rydberg states of camphor. Theoretical calculations are presented that model the photoelectron angular distribution from a prealigned camphor molecule using density functional theory and continuum multiple scattering X alpha photoelectron scattering calculations

  19. Electron-Ion Collider : The next QCD frontier

    NARCIS (Netherlands)

    Accardi, A.; Albacete, J. L.; Anselmino, M.; Armesto, N.; Aschenauer, E. C.; Bacchetta, A.; Boer, D.; Brooks, W. K.; Burton, T.; Chang, N. -B.; Deng, W. -T.; Deshpande, A.; Diehl, M.; Dumitru, A.; Dupre, R.; Ent, R.; Fazio, S.; Guzey, V.; Hakobyan, H.; Hao, Y.; Hasch, D.; Holt, R.; Horn, T.; Huang, M.; Hutton, A.; Hyde, C.; Jalilian-Marian, J.; Klein, S.; Kopeliovich, B.; Kovchegov, Y.; Kumar, K.; Kumericki, K.; Lamont, M. A. C.; Lappi, T.; Lee, J. -H.; Lee, Y.; Levin, E. M.; Lin, F. -L.; Litvinenko, V.; Ludlam, T. W.; Marquet, C.; Meziani, Z. -E.; McKeown, R.; Metz, A.; Milner, R.; Morozov, V. S.; Mueller, A. H.; Muller, B.; Mueller, D.; Nadel-Turonski, P.; Paukkunen, H.; Prokudin, A.; Ptitsyn, V.; Qian, X.; Qiu, J. -W.; Ramsey-Musolf, M.; Roser, T.; Sabatie, F.; Sassot, R.; Schnell, G.; Schweitzer, P.; Sichtermann, E.; Stratmann, M.; Strikman, M.; Sullivan, M.; Taneja, S.; Toll, T.; Trbojevic, D.; Ullrich, T.; Venugopalan, R.; Vigdor, S.; Vogelsang, W.; Weiss, C.; Xiao, B. -W.; Yuan, F.; Zhang, Y. -H.; Zheng, L.

    2016-01-01

    This White Paper presents the science case of an Electron-Ion Collider (EIC), focused on the structure and interactions of gluon-dominated matter, with the intent to articulate it to the broader nuclear science community. It was commissioned by the managements of Brookhaven National Laboratory (BNL)

  20. Ion-acoustic envelope modes in a degenerate relativistic electron-ion plasma

    Energy Technology Data Exchange (ETDEWEB)

    McKerr, M.; Kourakis, I. [Centre for Plasma Physics, School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN Belfast, Northern Ireland (United Kingdom); Haas, F. [Instituto de Física, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, Porto Alegre, RS (Brazil)

    2016-05-15

    A self-consistent relativistic two-fluid model is proposed for one-dimensional electron-ion plasma dynamics. A multiple scales perturbation technique is employed, leading to an evolution equation for the wave envelope, in the form of a nonlinear Schrödinger type equation (NLSE). The inclusion of relativistic effects is shown to introduce density-dependent factors, not present in the non-relativistic case—in the conditions for modulational instability. The role of relativistic effects on the linear dispersion laws and on envelope soliton solutions of the NLSE is discussed.

  1. Electron-ion thermal equilibration after spherical shock collapse

    Energy Technology Data Exchange (ETDEWEB)

    Rygg, J R; Frenje, J A; Li, C K; Seguin, F H; Petrasso, R D; Meyerhofer, D D; Stoeckl, C

    2009-08-14

    A comprehensive set of dual nuclear product observations provides a snapshot of imploding inertial confinement fusion capsules at the time of shock collapse, shortly before the final stages of compression. The collapse of strong convergent shocks at the center of spherical capsules filled with D{sub 2} and {sup 3}He gas induces D-D and D-{sup 3}He nuclear production. Temporal and spectral diagnostics of products from both reactions are used to measure shock timing, temperature, and capsule areal density. The density and temperature inferred from these measurements are used to estimate the electron-ion thermal coupling, and demonstrate a lower electron-ion relaxation rate for capsules with lower initial gas density.

  2. Analytical Schwartz density applied to heavy two-electron ions

    Energy Technology Data Exchange (ETDEWEB)

    Romera, E.; Dehesa, J.S. [Universidad de Granada (Spain); Koga, Toshikatsu [Muroran Institute of Technology (Japan)

    1997-01-20

    An analytical expression of the electron density function p(r) due to Schwartz for two-electron atomic systems is applied to a detailed study of density-dependent properties of relatively heavy two-electron ions. Comparison of the Schwartz results with those from accurate Hartree-Fock and Hylleraas wave functions shows that despite its simple yet analytical form, the Schwartz density has a quantitative applicability in the density study of two-electron atoms within the nonrelativistic framework. 13 refs., 4 tabs.

  3. Polarized Parton Distributions at an Electron-Ion Collider

    CERN Document Server

    Ball, Richard D.; Guffanti, Alberto; Nocera, Emanuele R.; Ridolfi, Giovanni; Rojo, Juan

    2014-01-01

    We study the potential impact of inclusive deep-inelastic scattering data from a future electron-ion collider (EIC) on longitudinally polarized parton distribution (PDFs). We perform a PDF determination using the NNPDF methodology, based on sets of deep-inelastic EIC pseudodata, for different realistic choices of the electron and proton beam energies. We compare the results to our current polarized PDF set, NNPDFpol1.0, based on a fit to fixed-target inclusive DIS data. We show that the uncertainties on the first moments of the polarized quark singlet and gluon distributions are substantially reduced in comparison to NNPDFpol1.0, but also that more measurements may be needed to ultimately pin down the size of the gluon contribution to the nucleon spin.

  4. Novel Plasmonic Photocathodes for Electron-Ion Colliders

    Energy Technology Data Exchange (ETDEWEB)

    Lukaszew, Rosa Alejandra [College of William and Mary, Williamsburg, VA (United States)

    2017-06-20

    Our aim was to explore new photocathode materials and schemes to develop strategies and technologies for next generation nuclear physics accelerator capabilities, particularly for Electron Ion Colliders (EIC). We successfully implemented an experimental setup for light incidence at an acute angle onto metallic photocathodes in UHV, in order to excite surface Plasmon resonance, hence increasing light absorption by the metallic surface and tested the photoemitted current. We successfully tested the setup with a hot cathode as well as Plasmonic silver-MgO samples and obtained excellent results. We extended our studies to shorter wavelengths to help defeat the work function of the metal. We also used oblique incidence thin film deposition onto gratings to achieve optimized Plasmonic excitation leading to stronger EM field and also lower emittance. We tested and used adequate software to model our samples and simulate our experimental results. We incorporated the concept of Fano resonances applied to gratings to better interpret our experimental results.

  5. Experiments using coincidence methods

    International Nuclear Information System (INIS)

    Anwar Dhani.

    1978-01-01

    Experiments on γ spectroscopy using the simple coincidence techniques, including investigation of angular distribution of γ radiation from annihilation process in decay of Na 22 , γ - γ angular correlation technique in decay of Co 60 , decay scheme study of Bi 207 and life time measurement of nuclear Pb 207 excited state have been carried out. (author)

  6. A β - γ coincidence

    International Nuclear Information System (INIS)

    Agullo, F.

    1960-01-01

    A β - γ coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from 1 98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs

  7. Coincidence studies with antiprotons

    Energy Technology Data Exchange (ETDEWEB)

    McGovern, M; Walters, H R J [Department of Applied Mathematics and Theoretical Physics, Queen' s University, Belfast BT7 1NN (United Kingdom); Assafrao, D; Mohallem, J R [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O Box 702, 30123-970 Belo Horizonte, MG (Brazil); Whelan, Colm T, E-mail: mmcgovern06@qub.ac.u [Department of Physics, Old Dominion University, Norfolk, VA 23529-0116 (United States)

    2010-02-01

    We present a short overview of a new method for calculating fully differential cross sections that is able to describe any aspect of coincidence measurements involving heavy projectiles. The method is based upon impact parameter close coupling with pseudostates. Examples from antiproton impact ionization are shown.

  8. Prospects in coincidence experiments

    International Nuclear Information System (INIS)

    Laget, J.M.

    1984-01-01

    The sensitivity of virtual photons to the local variations of the charge and magnetization densities is exploited to study the short-range part of the nucleon-nucleon interaction inside the nucleus. The possibility of varying energy, squared mass and longitudinal polarization of the photons independently enables us to disentangle the mechanisms related to the internal structure of the nucleon (e.g. quark interchange) and the contribution due to meson exchange. Coincidence experiments of the type (e,e'N) and (e,e'NN) are performed to suppress the meson contribution to the longitudinal part of the quasi-elastic peak. Four typical examples of coincidence experiments induced by virtual photons are discussed: experiments (1) on the spectroscopic structure of the quasi-elastic peak and the problem of deep lying hole states; (2) on the structure of the continuum; (3) on the low energy side of the quasi-elastic peak; and finally a three-arm coincidence experiment. (Auth.)

  9. Physics Opportunity with an Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Patrizia [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-12-01

    Understanding the emergence of nucleons and nuclei and their interactions from the properties and dynamics of quarks and gluons in Quantum Chromodynamics (QCD) is a fundamental and compelling goal of nuclear science. A high-energy, high-luminosity polarized electron-ion collider (EIC) will be needed to explore and advance many aspects of QCD studies in the gluon dominated regions in nucleon and nuclei. The federal Nuclear Science Advisory Committee unanimously approved a high-energy electro-ion collider to explore a new frontier in physics research. In fact, the committee calls the collider the country's next "highest priority" in new facility construction, and is one of four main recommendations contained in its 2015 Long Range Plan for Nuclear Science. Two proposals for the EIC are being considered in the U.S.: one each at Jefferson Laboratory (JLab) and at Brookhaven National Laboratory (BNL). An overview of the physics opportunities an EIC presents to the nuclear science community in future decades is presented.

  10. Device for monitoring electron-ion ring parameters

    International Nuclear Information System (INIS)

    Tyutyunnikov, S.I.; Shalyapin, V.N.

    1982-01-01

    The invention is classified as the method of collective ion acceleration. The device for electron-ion ring parameters monitoring is described. The invention is aimed at increasing functional possibilities of the device at the expense of the enchance in the number of the ring controlled parameters. The device comprises three similar plane mirrors installed over accelerating tube circumference and a mirror manufactured in the form of prism and located in the tube centre, as well as the system of synchrotron radiation recording and processing. Two plane mirrors are installed at an angle of 45 deg to the vertical axis. The angle of the third plane mirror 3 α and that of prismatic mirror 2 α to the vertical axis depend on geometric parameters of the ring and accelerating tube and they are determined by the expression α=arc sin R K /2(R T -L), where R K - ring radius, R T - accelerating tube radius, L - the height of segment, formed by the mirror and inner surface of the accelerating tube. The device suggested permits to determine longitudinal dimensions of the ring, its velocity and the number of electrons and ions in the ring

  11. Measuring the electron-ion ring parameters by bremsstrahlung

    International Nuclear Information System (INIS)

    Inkin, V.D.; Mozelev, A.A.; Sarantsev, V.P.

    1982-01-01

    A system is described for measuring the number of electrons and ions in the electron-ion rings of a collective heavy ion accelerator. The system operation is based on detecting gamma quanta of bremsstrahlung following the ring electron interaction with the nuclei of neutral atoms and ions at different stages of filling the ring with ions. The radiation detector is a scintillation block - a photomultiplier operating for counting with NaI(Tl) crystal sized 30x30 mm and ensuring the detection efficiency close to unity. The system apparatus is made in the CAMAC standard and rems on-line with the TRA/i miniature computer. The block-diagrams of the system and algorithm of data processing are presented. A conclusion is drawn that the results of measuring the ring parameters with the use of the diagnostics system described are in good agreement within the range of measuring errors with those obtained by means of the diagnostics system employing synchrotron radiation and induction sensors

  12. Nuclear structure functions at a future electron-ion collider

    Science.gov (United States)

    Aschenauer, E. C.; Fazio, S.; Lamont, M. A. C.; Paukkunen, H.; Zurita, P.

    2017-12-01

    The quantitative knowledge of heavy nuclei's partonic structure is currently limited to rather large values of momentum fraction x —robust experimental constraints below x ˜10-2 at low resolution scale Q2 are particularly scarce. This is in sharp contrast to the free proton's structure which has been probed in Deep Inelastic Scattering (DIS) measurements down to x ˜10-5 at perturbative resolution scales. The construction of an electron-ion collider (EIC) with a possibility to operate with a wide variety of nuclei, will allow one to explore the low-x region in much greater detail. In the present paper we simulate the extraction of the nuclear structure functions from measurements of inclusive and charm reduced cross sections at an EIC. The potential constraints are studied by analyzing simulated data directly in a next-to-leading order global fit of nuclear Parton Distribution Functions based on the recent EPPS16 analysis. A special emphasis is placed on studying the impact an EIC would have on extracting the nuclear gluon parton distribution function, the partonic component most prone to nonlinear effects at low Q2. In comparison to the current knowledge, we find that the gluon parton distribution function can be measured at an EIC with significantly reduced uncertainties.

  13. A New Simulation Framework for the Electron-Ion Collider

    Science.gov (United States)

    Arrington, John

    2017-09-01

    Last year, a collaboration between Physics Division and High-Energy Physics at Argonne was formed to enable significantly broader contributions to the development of the Electron-Ion Collider. This includes efforts in accelerator R&D, theory, simulations, and detector R&D. I will give a brief overview of the status of these efforts, with emphasis on the aspects aimed at enabling the community to more easily become involved in evaluation of physics, detectors, and details of spectrometer designs. We have put together a new, easy-to-use simulation framework using flexible software tools. The goal is to enable detailed simulations to evaluate detector performance and compare detector designs. In addition, a common framework capable of providing detailed simulations of different spectrometer designs will allow for fully consistent evaluations of the physics reach of different spectrometer designs or detector systems for a variety of physics channels. In addition, new theory efforts will provide self-consistent models of GPDs (including QCD evolution) and TMDs in nucleons and light nuclei, as well as providing more detailed physics input for the evaluation of some new observables. This material is based upon work supported by Laboratory Directed Research and Development (LDRD) funding from Argonne National Laboratory, provided by the Director, Office of Science, of the U.S. Department of Energy under Contract DE-AC02-06CH11357.

  14. Development of rheumatoid arthritis during treatment of multiple sclerosis with interferon beta 1-a. Coincidence of two conditions or a complication of treatment: A case report.

    Science.gov (United States)

    Hojjati, Seyed Mohammad Masood; Heidari, Behzad; Babaei, Mansour

    2016-09-01

    Coexistence of multiple sclerosis (MS) with other autoimmune diseases has been attributed to common background genetic or environmental factors. This study presents development of rheumatoid arthritis (RA) during treatment of MS. The MS was confirmed by the Mc Donald criteria and the diagnosis of RA was confirmed by the ACR/EULAR criteria. A 35 years old women with 9 years of MS who was receiving interferon beta 1-a (INF) for 7 years and who did not respond to conventional therapy of RA over 8 months developed clinical manifestations of RA. But a rapid response was observed after discontinuation of INF. These findings suggest a possible contribution of INF in the development of RA.

  15. Development of rheumatoid arthritis during treatment of multiple sclerosis with interferon beta 1-a. Coincidence of two conditions or a complication of treatment: A case report

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Masood Hojjati

    2016-09-01

    Full Text Available Coexistence of multiple sclerosis (MS with other autoimmune diseases has been attributed to common background genetic or environmental factors. This study presents development of rheumatoid arthritis (RA during treatment of MS. The MS was confirmed by the Mc Donald criteria and the diagnosis of RA was confirmed by the ACR/EULAR criteria. A 35 years old women with 9 years of MS who was receiving interferon beta 1-a (INF for 7 years and who did not respond to conventional therapy of RA over 8 months developed clinical manifestations of RA. But a rapid response was observed after discontinuation of INF. These findings suggest a possible contribution of INF in the development of RA.

  16. Design studies for the next generation electron ion colliders

    Energy Technology Data Exchange (ETDEWEB)

    Sayed, Hisham Kamal [BNL; Bogacz, Slawomir A. [JLAB; Krafft, Geoffrey A. [JLAB

    2014-04-01

    The next generation Electron Ion Collider (EIC) at Thomas Jefferson National Accelerator Facility (JLAB) utilizes a figure-8 shaped ion and electron rings. EIC has the ability to preserve the ion polarization during acceleration, where the electron ring matches in footprint with a figure-8 ion ring. The electron ring is designed to deliver a highly polarized high luminous electron beam at interaction point (IP). The main challenges of the electron ring design are the chromaticity compensation and maintaining high beam polarization of 70% at all energies 3–11 GeV without introducing transverse orbital coupling before the IP. The very demanding detector design limits the minimum distance between the final focus quadrupole and the interaction point to 3.5 m which results in a large β function inside the final focus quadrupoles leading to increased beam chromaticity. In this paper, we present a novel chromaticity compensation scheme that mitigates IP chromaticity by a compact chromaticity compensation section with multipole magnet components. In addition, a set of spin rotators are utilized to manipulate the polarization vector of the electron beam in order to preserve the beam polarization. The spin rotator solenoids introduce undesired coupling between the horizontal and vertical betatron motion of the beam. We introduce a compact and modular orbit decoupling insert that can fit in the limited space of the straight section in the figure-8 ring. We show a numerical study of the figure-8 ring design with the compact straight section, which includes the interaction region, chromaticity compensation section, and the spin rotators, the figure-8 design performance is evaluated with particle tracking.

  17. Shift register neutron coincidence module

    International Nuclear Information System (INIS)

    Stephens, M.M.; Swansen, J.E.; East, L.V.

    1975-11-01

    A neutron coincidence module was designed using multistage shift registers to produce the coincidence gates and a crystal controlled oscillator with variable clock outputs to change the gate lengths. The advantage of this system over the conventional, thermal-neutron coincidence gates is a decrease in deadtime by more than an order of magnitude

  18. Correlated electron-ion collisions in a strong laser field

    International Nuclear Information System (INIS)

    Ristow, T.

    2007-01-01

    Electron-ion-collisions in plasmas in the presence of an ultra-short intensive laser pulse can cause high energy transfers to the electrons. During the collision the oscillation energy of the electron in the laser field is changed into drift energy. In this regime, multi-photon processes, known from the ionization of neutral atoms (Above-Threshold Ionization), and successive, so called correlated collisions, are important. The subject of the thesis is a study of binary Coulomb collisions in strong laser fields. The collisions are treated both in the context of classical Newtonian mechanics and in the quantum-mechanical framework by the Schroedinger equation. In the classical case a simplified instantaneous collision model and a complete dynamical treatment are discussed. Collisions can be treated instantaneously, if the ratio of the impact parameter to the quiver amplitude is small. The energy distributions calculated in this approximation show an elastic peak and a broad plateau due to rescattered electrons. At incident velocities smaller than the quiver velocity, correlated collisions are observed in the electron trajectories of the dynamical model. This effect leads to characteristic momentum distributions of the electrons, that are explicitly calculated and compared with the results of the instantaneous model. In addition, the time-dependence of the collisions is discussed in the framework of a singular perturbation theory. The complete description of the Coulomb scattering requires a quantum-mechanical description. A time-dependent method of wave-packet scattering is used and the corresponding time-dependent three-dimensional Schroedinger equation is solved by an implicit ADImethod on a spatial grid. The momentum and the energy distributions of the scattered electrons are calculated by the Fourier transformation of the wavefunction. A comparison of the scattering from a repulsive and an attractive potential is used to distinguish between simple collisions and

  19. Crabbing system for an electron-ion collider

    Energy Technology Data Exchange (ETDEWEB)

    Castilla, Alejandro [Old Dominion Univ., Norfolk, VA (United States)

    2017-05-01

    As high energy and nuclear physicists continue to push further the boundaries of knowledge using colliders, there is an imperative need, not only to increase the colliding beams' energies, but also to improve the accuracy of the experiments, and to collect a large quantity of events with good statistical sensitivity. To achieve the latter, it is necessary to collect more data by increasing the rate at which these processes are being produced and detected in the machine. This rate of events depends directly on the machine's luminosity. The luminosity itself is proportional to the frequency at which the beams are being delivered, the number of particles in each beam, and inversely proportional to the cross-sectional size of the colliding beams. There are several approaches that can be considered to increase the events statistics in a collider other than increasing the luminosity, such as running the experiments for a longer time. However, this also elevates the operation expenses, while increasing the frequency at which the beams are delivered implies strong physical changes along the accelerator and the detectors. Therefore, it is preferred to increase the beam intensities and reduce the beams cross-sectional areas to achieve these higher luminosities. In the case where the goal is to push the limits, sometimes even beyond the machines design parameters, one must develop a detailed High Luminosity Scheme. Any high luminosity scheme on a modern collider considers|in one of their versions|the use of crab cavities to correct the geometrical reduction of the luminosity due to the beams crossing angle. In this dissertation, we present the design and testing of a proof-of-principle compact superconducting crab cavity, at 750 MHz, for the future electron-ion collider, currently under design at Jefferson Lab. In addition to the design and validation of the cavity prototype, we present the analysis of the first order beam dynamics and the integration of the

  20. Quantum theory of incoherent THz emission of an interacting electron-ion plasma

    Science.gov (United States)

    Richter, M.; Schaarschmidt, M.; Knorr, A.; Hoyer, W.; Moloney, J. V.; Wright, E. M.; Kira, M.; Koch, S. W.

    2005-05-01

    The THz spectrum of the spontaneous emission of an interacting electron-ion gas, recently observed in laser pulse ionized air, is theoretically analyzed. Using the correlation expansion of the involved many particle system, the contribution of electron-molecule and electron-ion collisions to the transitions in the free electron continuum are treated. Depending on the particle density and the ion distribution, electromagnetic emission is found from the terahertz range up to optical frequencies.

  1. Coincidence method for determination of radionuclides activities

    International Nuclear Information System (INIS)

    Andrukhovich, S.K.; Berestov, A.V.; Rudak, E.A.

    2004-01-01

    The radon and radium activity measurements using six-crystal gamma-gamma coincidence, 4 -spectrometer PRIPJAT and radioactivity measurements in different samples of meat and vegetation by 32-crystal spectrometer ARGUS, are described. Radiation detector with 4 -geometry provides higher efficiency, and therefore shorter counting time than a detector without such geometry. However, its application is limited by the fact that obtained spectrum contains summing peaks of all γ-quanta registered in coincidence. Multiparameter information on coincident photon emission can be obtained only by a detection system where the 4 -geometry is made by many detectors, such are both the PRIPJAT and the ARGUS - γ-coincidence spectrometer of the Crystal Ball type in the Institute of Physics, Minsk [1,2]. There are other characteristics, as background conditions, energy and time resolution, makes it ve suitable for investigation of rare decays and interactions, cascade transitions, k intensity radiations etc. We are developing a method of 2 26R a and 2 26 Rn measurement by a multidetector 4 -spectrometer. The method is based on coincidence counting of γ-rays from two step cascade transitions that follow - decay of 2 14 Bi. Its application to the PRIPL spectrometer, which has 6 Nal(Tl) detectors, is presented here, as well as the method of the determination of radionuclide activities based on the registration of the cascades intensity of γ-rays of different multiplicity using ARGUS

  2. Flow shear stabilization of hybrid electron-ion drift mode in tokamaks

    International Nuclear Information System (INIS)

    Bai, L.

    1999-01-01

    In this paper, a model of sheared flow stabilization on hybrid electron-ion drift mode is proposed. At first, in the presence of dissipative trapped electrons, there exists an intrinsic oscillation mode in tokamak plasmas, namely hybrid dissipative trapped electron-ion temperature gradient mode (hereafter, called as hybrid electron-ion drift mode). This conclusion is in agreement with the observations in the simulated tokamak experiment on the CLM. Then, it is found that the coupling between the sheared flows and dissipative trapped electrons is proposed as the stabilization mechanism of both toroidal sheared flow and poloidal sheared flow on the hybrid electron-ion drift mode, that is, similar to the stabilizing effect of poloidal sheared flow on edge plasmas in tokamaks, in the presence of both dissipative trapped electrons and toroidal sheared flow, large toroidal sheared flow is always a strong stabilizing effect on the hybrid electron-ion drift mode in internal transport barrier location, too. This result is consistent with the experimental observations in JT-60U. (author)

  3. Flow shear stabilization of hybrid electron-ion drift mode in tokamaks

    International Nuclear Information System (INIS)

    Bai, L.

    2001-01-01

    In this paper, a model of sheared flow stabilization on hybrid electron-ion drift mode is proposed. At first, in the presence of dissipative trapped electrons, there exists an intrinsic oscillation mode in tokamak plasmas, namely hybrid dissipative trapped electron-ion temperature gradient mode (hereafter, called as hybrid electron-ion drift mode). This conclusion is in agreement with the observations in the simulated tokamak experiment on the CLM. Then, it is found that the coupling between the sheared flows and dissipative trapped electrons is proposed as the stabilization mechanism of both toroidal sheared flow and poloidal sheared flow on the hybrid electron-ion drift mode, that is, similar to the stabilizing effect of poloidal sheared flow on edge plasmas in tokamaks, in the presence of both dissipative trapped electrons and toroidal sheared flow, large toroidal sheared flow is always a strong stabilizing effect on the hybrid electron-ion drift mode in internal transport barrier location, too. This result is consistent with the experimental observations in JT-60U. (author)

  4. Quantum ion acoustic solitary waves in electron-ion plasmas: A Sagdeev potential approach

    International Nuclear Information System (INIS)

    Mahmood, S.; Mushtaq, A.

    2008-01-01

    Linear and nonlinear ion acoustic waves are studied in unmagnetized electron-ion quantum plasmas. Sagdeev potential approach is employed to describe the nonlinear quantum ion acoustic waves. It is found that density dips structures are formed in the subsonic region in a electron-ion quantum plasma case. The amplitude of the nonlinear structures remains constant and the width is broadened with the increase in the quantization of the system. However, the nonlinear wave amplitude is reduced with the increase in the wave Mach number. The numerical results are also presented

  5. Projectile K-Auger-electron production by bare, one-, and two-electron ions

    International Nuclear Information System (INIS)

    Dillingham, T.R.; Newcomb, J.; Hall, J.; Pepmiller, P.L.; Richard, P.

    1984-01-01

    Projectile K-Auger-electron production measurements were performed for the bare, one-, and two-electron ions of C, N, O, and F incident on He, Ne, Ar, and Kr gases. The measurements were taken over an energy range of (1/4) to (2/3) MeV/amu using a cylindrical mirror analyzer. For the incident two-electron ions, single-electron capture to excited states of the (1s2s) 3 S metastable component of the incident beam was the principal mechanism giving rise to the observed K-Auger transitions. For the bare and one-electron ions, double electron capture to excited states was the dominant mechanism leading to K-Auger-electron production. In addition to Auger-spectroscopy measurements, total K-Auger production cross sections were determined as well as the partial cross sections for electron capture to specific n levels of the projectile. The n distributions were also measured for double electron capture to excited states of the bare and one-electron ions

  6. Systematics of projectile K-Auger electron production by bare, one, and two electron ions

    International Nuclear Information System (INIS)

    Dillingham, T.R.

    1983-01-01

    Projectile K-Auger electron production measurements were performed for the bare, one, and two electron ions of C, N, O, and F incident on He, Ne, Ar, and Kr gases. The measurements were taken over an energy range of 1/4 to 2/3 MeV/amu using a cylindrical mirror analyzer. For the incident two electron ions, single electron capture to excited states of the (1s2s) 3 S metastable component of the incident beam was the principal mechanism giving rise to the observed K-Auger transitions. For the bare and one electron ions, double electron capture to excited states was the dominant mechanism leading to K-Auger electron production. In addition to Auger spectroscopy measurements, total K-Auger production cross sections were determined as well as the partial cross sections for electron capture to specific n-levels of the projectile. The n-distribution for single electron capture was observed to follow a 1/n 3 dependence. The n-distributions were also measured for double electron capture to excited states of the bare and one electron ions

  7. Predictions for exclusive vector meson production in the electron-ion collider

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, V.P. [Instituto de Fisica e Matematica, Universidade Federal de Pelotas C. P. 354, 96010-090 Pelotas, RS (Brazil); Kugeratski, M.S. [Instituto de Fisica, Universidade de Sao Paulo C. P. 66318, 05315-970 Sao Paulo, SP (Brazil); Machado, M.V.T. [Centro de Ciencias Exatas e Tecnologicas, Universidade Federal do Pampa Campus de Bage Rua Carlos Barbosa, 96400-970 Bage, RS (Brazil); Navarra, F.S. [Instituto de Fisica, Universidade de Sao Paulo C. P. 66318, 05315-970 Sao Paulo, SP (Brazil)

    2010-02-15

    We calculate the nuclear cross section for coherent and incoherent vector meson production within the QCD color dipole picture, including saturation effects. Predictions for scattering on both light and heavy nuclei are given over a wide range of energy. Our analysis shows that coherent process should be dominant in the future electron-ion collider.

  8. ELECTRON-ION CORRELATION IN LIQUID-METALS FROM FIRST PRINCIPLES - LIQUID MG AND LIQUID PI

    NARCIS (Netherlands)

    DEWIJS, GA; PASTORE, G; SELLONI, A; VANDERLUGT, W

    1995-01-01

    We present a theoretical determination of electron-ion pair correlation functions g(ie) in liquid Mg and liquid Bi, two systems with widely different electronic and cohesive properties. Our calculations are based on first-principles molecular-dynamics simulations, which provide an accurate and

  9. Theoretical research of electron-ion direct impact excitation cross sections for hot dense plasma

    International Nuclear Information System (INIS)

    Tian Mingfeng

    2003-01-01

    An average-atom (AA) model, Younger formula and partial wave method are employed to study the electron- ion direct impact excitation cross sections for hot dense plasma. The phenomenon of electron resonance near the excitation threshold and its mechanism are discussed. (author)

  10. On the electron-ion temperature ratio established by collisionless shocks

    Science.gov (United States)

    Vink, Jacco; Broersen, Sjors; Bykov, Andrei; Gabici, Stefano

    2015-07-01

    Astrophysical shocks are often collisionless shocks, in which the changes in plasma flow and temperatures across the shock are established not through Coulomb interactions, but through electric and magnetic fields. An open question about collisionless shocks is whether electrons and ions each establish their own post-shock temperature (non-equilibration of temperatures), or whether they quickly equilibrate in the shock region. Here we provide a simple, thermodynamic, relation for the minimum electron-ion temperature ratios that should be expected as a function of Mach number. The basic assumption is that the enthalpy-flux of the electrons is conserved separately, but that all particle species should undergo the same density jump across the shock, in order for the plasma to remain charge neutral. The only form of additional electron heating that we allow for is adiabatic heating, caused by the compression of the electron gas. These assumptions result in an analytic treatment of expected electron-ion temperature ratio that agrees with observations of collisionless shocks: at low sonic Mach numbers, Ms ≲ 2, the electron-ion temperature ratio is close to unity, whereas for Mach numbers above Ms ≈ 60 the electron-ion temperature ratio asymptotically approaches a temperature ratio of Te/Ti = me/ ⟨ mi ⟩. In the intermediate Mach number range the electron-ion temperature ratio scales as Te/Ti ∝ Ms-2. In addition, we calculate the electron-ion temperature ratios under the assumption of adiabatic heating of the electrons only, which results in a higher electron-ion temperature ratio, but preserves the Te/Ti ∝ Ms-2 scaling. We also show that for magnetised shocks the electron-ion temperature ratio approaches the asymptotic value Te/Ti = me/ ⟨ mi ⟩ for lower magnetosonic Mach numbers (Mms), mainly because for a strongly magnetised shock the sonic Mach number is larger than the magnetosonic Mach number (Mms ≤ Ms). The predicted scaling of the electron-ion

  11. Heavy ion beam loss mechanisms at an electron-ion collider

    Directory of Open Access Journals (Sweden)

    Spencer R. Klein

    2014-12-01

    Full Text Available There are currently several proposals to build a high-luminosity electron-ion collider, to study the spin structure of matter and measure parton densities in heavy nuclei, and to search for gluon saturation and new phenomena like the colored glass condensate. These measurements require operation with heavy nuclei. We calculate the cross sections for two important processes that will affect accelerator and detector operations: bound-free pair production and Coulomb excitation of the nuclei. Both of these reactions have large cross sections, 28–56 mb, which can lead to beam ion losses, produce beams of particles with altered charge:mass ratio, and produce a large flux of neutrons in zero degree calorimeters. The loss of beam particles limits the sustainable electron-ion luminosity to levels of several times 10^{32}/cm^{2}/s.

  12. Effect of electron-ion equilibration on optical emission from a shock wave

    International Nuclear Information System (INIS)

    Chiu, G.; Ng, A.; Forsman, A.

    1997-01-01

    Optical emission from a shock wave emerging from a free surface is studied using numerical simulations taking into account the effect of temperature equilibration between electrons and ions. The results show significant variations depending on the equilibration rate. They also illustrate how measurements of the absolute intensity, relative spectral intensities, and temporal history of such emission can provide a new and important means for determining electron-ion equilibration rate in dense matter. copyright 1997 The American Physical Society

  13. A cold cathode of a gas-discharge electron-ion gun

    International Nuclear Information System (INIS)

    1974-01-01

    A cold cathode of a gas-discharge electron-ion gun is constructed in order to continuously replace the eroded material by feeding a wire or a set of coaxial cylinders in the spot where the ions hit the cathode. In this way, the form of the cathode and the electric-field configuration is preserved which guarantees the conservation of a sharp narrow electron beam profile

  14. Relativistic Shear Flow between Electron-Ion and Electron-Positron Plasmas and Astrophysical Applications

    Science.gov (United States)

    Liang, Edison; Fu, Wen; Böttcher, Markus

    2017-10-01

    We present particle-in-cell simulation results of relativistic shear boundary layers between electron-ion and electron-positron plasmas and discuss their potential applications to astrophysics. Specifically, we find that in the case of a fast electron-positron spine surrounded by a slow-moving or stationary electron-ion sheath, lepton acceleration proceeds in a highly anisotropic manner due to electromagnetic fields created at the shear interface. While the highest-energy leptons still produce a beaming pattern (as seen in the quasi-stationary frame of the sheath) of order 1/Γ, where Γ is the bulk Lorentz factor of the spine, for lower-energy particles, the beaming is much less pronounced. This is in stark contrast to the case of pure electron-ion shear layers, in which anisotropic particle acceleration leads to significantly narrower beaming patterns than 1/Γ for the highest-energy particles. In either case, shear-layer acceleration is expected to produce strongly angle-dependent lepton (hence, emanating radiation) spectra, with a significantly harder spectrum in the forward direction than viewed from larger off-axis angles, much beyond the regular Doppler boosting effect from a co-moving isotropic lepton distribution. This may solve the problem of the need for high (and apparently arbitrarily chosen) minimum Lorentz factors of radiating electrons, often plaguing current blazar and GRB jet modeling efforts.

  15. Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Bourva, L.C.A.; Croft, S.

    1999-01-01

    basis, previously published analytical results for the double exponential case are thought to be in error. As derived analytically, the numerical calculations have been found to be both independent of the detector's efficiency and of the spontaneous fission neutron multiplicity distribution used in the Monte Carlo calculations. Extension of the MCF calculations to multiplicity counting, and in particular to triple coincidence counting, confirmed that, for a single exponential die-away profile, the triple gate utilisation factor is equal to the square of the real gate utilisation factor. For other profiles this relation no longer holds. An analytical expression is given for the case of a double exponential profile. Comparison of the MCF results with earlier calculated estimates of the gate utilisation factor for the on-site laboratory neutron coincidence chamber showed a significant difference. Use of the MCF results led to much better agreement between the observed and calculated specific reals coincidence rate of the on-site laboratory counter for the assay of plutonium samples. Moreover, the present work constitutes a further step towards the improvement of the accuracy of absolute Monte Carlo calculations for active or passive neutron measurements of nuclear materials. (author)

  16. A Harmonic Kicker Scheme for the Circulator Cooler Ring in the Proposed Medium Energy Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Nissen, Edward W.; Hutton, Andrew M.; Kimber, Andrew J.

    2013-06-01

    The current electron cooler design for the proposed Medium Energy Electron-Ion collider (MEIC) at Jefferson Lab utilizes a circulator ring for reuse of the cooling electron bunch up to 100 times to cool the ion beams. This cooler requires a fast kicker system for injecting and extracting individual bunches in the circulator ring. Such a kicker must work at a high repetition rate, up to 7.5 to 75 MHz depending on the number of turns in the recirculator ring. It also must have a very short rise and fall time (of order of 1 ns) such that it will kick an individual bunch without disturbing the others in the ring. Both requirements are orders of magnitude beyond the present state-of-the-art as well as the goals of other on-going kicker R&D programs such as that for the ILC damping rings. In this paper we report a scheme of creating this fast, high repetition rate kicker by combining RF waveforms at multiple frequencies to create a kicker waveform that will, for example, kick every eleventh bunch while leaving the other ten unperturbed. We also present a possible implementation of this scheme as well as discuss its limitations.

  17. Effects of Crab Cavities' Multipole Content in an Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Satogata, Todd J. [Jefferson Lab., Newport News, VA (United States); Morozov, Vasiliy [Jefferson Lab., Newport News, VA (United States); Delayen, Jean R. [Old Dominion Univ., Norfolk, VA (United States); Jefferson Lab., Newport News, VA (United States); Castillo, Alejandro [Old Dominion Univ., Norfolk, VA (United States)

    2015-09-01

    The impact on the beam dynamics of the Medium Energy Electron-Ion Colider (MEIC) due to the multipole content of the 750 MHz crab cavity was studied using thin multipole elements for 6D phase space particle tracking in ELEGANT. Target values of the sextupole component for the cavity’s field expansion were used to perform preliminary studies on the proton beam stability when compared to the case of pure dipole content of the rf kicks. Finally, important effects on the beam sizes due to non-linear components of the crab cavities’ fields were identified, and some criteria for their future study were proposed.

  18. Interaction Region Design for the Electron-Ion Collider eRHIC

    CERN Document Server

    Montag, Christoph; Tepikian, Steven; Wang, Dong

    2005-01-01

    To facilitate the study of collisions between 10 GeV polarized electrons and 100 GeV/u heavy ions or 250 GeV polarized protons at high luminosities, adding a 10 GeV electron storage ring to the existing RHIC complex has been proposed. The interaction region of this electron-ion collider eRHIC has to provide the required low-beta focusing, while simultaneously accomodating the synchrotron radiation fan generated by beam separation close to the interaction point, which is particularly challenging. The latest design status of the eRHIC interaction region is presented.

  19. Electron-ion plasma dynamics in the presence of highly charged dust-clusters

    Energy Technology Data Exchange (ETDEWEB)

    Djebli, Mourad, E-mail: mdjebli@usthb.dz; Benkhelifa, El-Amine [USTHB, Faculty of Physics, Theoretical Physics Laboratory, B.P. 32 Bab-Ezzouar, 16079 Algiers (Algeria)

    2015-05-15

    Electron-ion plasma expansion is studied in the presence of positively (negatively) highly charged uniformly distributed dust particles, considered as impurities. For that purpose, a multi-fluid model is used, where the charged impurities characteristics are included in Poisson's equation. We found that ion acceleration is enhanced by the presence of positively charged dust. The latter leads to spiky structures in the ion front which have a higher amplitude as the charge increases. The charged impurities have a significant effect when the combination of their charge and density is greater than a critical value which depends on ion to electron temperature ratio.

  20. Preliminary cryogenic loads requirements for the electron-ion collider at Brookhaven National Laboratory

    Science.gov (United States)

    Than, R.; Ravikumar, D. K.

    2017-12-01

    The proposed electron ion collider at Brookhaven National Laboratory will consist of using one existing hadron ring and developing a new electron accelerator. This paper presents the cryogenic loads for the hadron ring’s superconducting magnets as well as related upgrades to handle the additional loads. The cryogenic loads for the superconducting RF injector/accelerator and storage ring for the electron beam are summarized. The proposed cryogenic plant, and the configuration and flow distribution of the related cryogenic systems are also presented.

  1. Directional modulation of electron-ion pairs recombination in liquid argon

    Science.gov (United States)

    Cataudella, V.; de Candia, A.; De Filippis, G.; Catalanotti, S.; Cadeddu, M.; Lissia, M.; Rossi, B.; Galbiati, C.; Fiorillo, G.

    2017-12-01

    Motivated by the ongoing study of a possible directional signal in liquid argon dark matter detectors, we introduce a new model describing the recombination of electron-ion pairs in ionizing tracks in liquid argon in the presence of a drift field. The emphasis is on the three-dimensional distribution of electrons and ions and on their orientation relative to that of the electric field. We successfully apply our model to describe the angular dependence of the ionization signal of protons recently reported in measurements performed by the ArgoNeuT Collaboration with a liquid argon time projection chamber.

  2. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  3. A training and educational tool for neutron coincidence measurements

    International Nuclear Information System (INIS)

    Huszti, J.; Bagi, J.; Langner, D.

    2009-01-01

    Neutron coincidence counting techniques are widely used for nuclear safeguards inspection. They are based on the detection of time correlated neutrons created from spontaneous or induced fission of plutonium and some other actinides. IAEA inspectors are trained to know and to use this technique, but it is not easy to illustrate and explain the basics of the neutron coincidence counting. The traditional shift registers or multiplicity counters give only multiplicity distributions and the singles, doubles and triples count rates. Using the list mode method for the recording and evaluation of neutron coincidence data makes it easier to teach this technique. List mode acquisition is a relatively new way to collect data in neutron coincidence counting. It is based on the recording of the follow-up times of neutron pulses originating from a neutron detector into a file. The recorded pulse train can be evaluated with special software after the measurement. Hardware and software for list mode neutron coincidence acquisition have been developed in the Institute of Isotopes and is called a Pulse Train Reader. A system called Virtual Source for replaying pulse trains registered with the list mode device has also been developed. The list mode device and the pulse train 're-player' together build a good educational tool for teaching the basics of neutron coincidence counting. Some features of the follow-up time, multiplicity and Rossi-alpha distributions can be well demonstrated by replaying artificially generated or pre-recorded pulse trains. The choice of real sources is stored on DVD. There is no need to transport and maintain real sources for the training. Virtual sources also give the possibility of investigating rare sources that trainees would not have access to otherwise. (authors)

  4. Science Requirements and Conceptual Design for a Polarized Medium Energy Electron-Ion Collider at Jlab

    Energy Technology Data Exchange (ETDEWEB)

    Abeyratne, S; Ahmed, S; Barber, D; Bisognano, J; Bogacz, A; Castilla, A; Chevtsov, P; Corneliussen, S; Deconinck, W; Degtiarenko, P; Delayen, J; Derbenev, Ya; DeSilva, S; Douglas, D; Dudnikov, V; Ent, R; Erdelyi, B; Evtushenko, P; Fujii, Yu; Filatov, Yury; Gaskell, D; Geng, R; Guzey, V; Horn, T; Hutton, A; Hyde, C; Johnson, R; Kim, Y; Klein, F; Kondratenko, A; Kondratenko, M; Krafft, G; Li, R; Lin, F; Manikonda, S; Marhauser, F; McKeown, R; Morozov, V; Dadel-Turonski, P; Nissen, E; Ostroumov, P; Pivi, M; Pilat, F; Poelker, M; Prokudin, A; Rimmer, R; Satogata, T; Sayed, H; Spata, M; Sullivan, M; Tennant, C; Terzic, B; Tiefenback, M; Wang, M; Wang, S; Weiss, C; Yunn, B

    2012-08-01

    Researchers have envisioned an electron-ion collider with ion species up to heavy ions, high polarization of electrons and light ions, and a well-matched center-of-mass energy range as an ideal gluon microscope to explore new frontiers of nuclear science. In its most recent Long Range Plan, the Nuclear Science Advisory Committee (NSAC) of the US Department of Energy and the National Science Foundation endorsed such a collider in the form of a 'half-recommendation.' As a response to this science need, Jefferson Lab and its user community have been engaged in feasibility studies of a medium energy polarized electron-ion collider (MEIC), cost-effectively utilizing Jefferson Lab's already existing Continuous Electron Beam Accelerator Facility (CEBAF). In close collaboration, this community of nuclear physicists and accelerator scientists has rigorously explored the science case and design concept for this envisioned grand instrument of science. An electron-ion collider embodies the vision of reaching the next frontier in Quantum Chromodynamics - understanding the behavior of hadrons as complex bound states of quarks and gluons. Whereas the 12 GeV Upgrade of CEBAF will map the valence-quark components of the nucleon and nuclear wave functions in detail, an electron-ion collider will determine the largely unknown role sea quarks play and for the first time study the glue that binds all atomic nuclei. The MEIC will allow nuclear scientists to map the spin and spatial structure of quarks and gluons in nucleons, to discover the collective effects of gluons in nuclei, and to understand the emergence of hadrons from quarks and gluons. The proposed electron-ion collider at Jefferson Lab will collide a highly polarized electron beam originating from the CEBAF recirculating superconducting radiofrequency (SRF) linear accelerator (linac) with highly polarized light-ion beams or unpolarized light- to heavy-ion beams from a new ion accelerator and storage complex. Since the very

  5. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  6. RF System Requirements for a Medium-Energy Electron-Ion Collider (MEIC) at JLab

    International Nuclear Information System (INIS)

    JLab is studying options for a medium energy electron-ion collider that could fit on the JLab site and use CEBAF as a full-energy electron injector. A new ion source, linac and booster would be required, together with collider storage rings for the ions and electrons. In order to achieve the maximum luminosity these will be high-current storage rings with many bunches. We present the high-level RF system requirements for the storage rings, ion booster ring and high-energy ion beam cooling system, and describe the technology options under consideration to meet them. We also present options for staging that might reduce the initial capital cost while providing a smooth upgrade path to a higher final energy. The technologies under consideration may also be useful for other proposed storage ring colliders or ultimate light sources.

  7. Laboratory investigation of electric charging of dust particles by electrons, ions, and UV radiation

    Science.gov (United States)

    Svestka, Jiri; Pinter, S.; Gruen, E.

    1989-01-01

    In many cosmic environments electric charging of dust particles occurs by electrons, ions, and UV radiation. In case of interstellar dust particles the value of their electric charge can have, for instance, very important consequences for their destruction rate in supernova remnant's shock waves and can globally influence the overall life cycle of dust particles in galaxies. For experimental simulation of charging processes a vacuum chamber was used in which the particles fall through an electron or ion beam of energies up to 10 KeV. The aim of the experiments was to attain maximum charge of dust particles. Furthermore the influence of the rest gas was also determined because electrons and ions produced by collisional ionization of the rest gas can result in significant effects. For measurement particles from 1 to 100 microns from glass, carbon, Al, Fe, MgO, and very loosely bound conglomerates of Al2O3 were used.

  8. Study of device of electron-ion treatment of mother baking yeasts

    International Nuclear Information System (INIS)

    Ostapenkov, A.M.; Merinov, N.S.; Nazarov, V.N.; Balan, E.L.

    1980-01-01

    Devices for electron- ion treatment of mother baking yeasts are considered and classified by the way of aerions removal from the ionization zone: the first ones - by means of the electric field, the other - by air directed flux. Devices of the first type require high voltage - 20-60 kV. Electrodynamic ion generator has been applied as a device of the second type; considered is its construction, principal of operation, given are diagrams of ion flux dependence. The methods of process calculations in the generator and experimental results are presented. The main advantage of the generator of the second type is operation at low (3-5 kV) voltages. It is shown, that the yeast growth module can achieve 36% at essential increase of biomass when using these yeasts as sowing. The device can be used for biostimulation and antisepting of food raw materials

  9. Analyses of 476 MHz and 952 MHz Crab Cavities for JLAB Electron Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Park, HyeKyoung [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Old Dominion Univ., Norfolk, VA (United States); Castilla, Alejandro [Old Dominion Univ., Norfolk, VA (United States); Delayen, Jean R. [Old Dominion Univ., Norfolk, VA (United States); De Silva, Subashini U. [Old Dominion Univ., Norfolk, VA (United States); Morozov, Vasiliy [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-05-01

    The Center for Accelerator Science at Old Dominion University has designed, fabricated and successfully tested a crab cavity for Electron Ion Collider at Jefferson Lab (JLEIC) [1]. This proof-of-principle cavity was based on the earlier MEIC design which used 748.5 MHz RF system. The updated JLEIC (called MEIC earlier) design [2] utilizes the components from PEP-II. It results in the change on the bunch repetition rate of stored beam to 476.3 MHz. The ion ring collider will eventually require 952.6 MHz crab cavities. This paper will present the analyses of crab cavities of both 476 MHz and 952 MHz options. It compares advantages and disadvantages of the options which provide the JLEIC design team important technical information for a system down selection.

  10. The Strength of Chaos: Accurate Simulation of Resonant Electron Scattering by Many-Electron Ions and Atoms in the Presence of Quantum Chaos

    Science.gov (United States)

    2017-01-20

    AFRL-AFOSR-JP-TR-2017-0012 The Strength of Chaos: accurate simulation of resonant electron scattering by many-electron ions and atoms in the presence...SUBTITLE The Strength of Chaos: accurate simulation of resonant electron scattering by many- electron ions and atoms in the presence of quantum chaos...Strength of Chaos: accurate simulation of resonant electron scattering by many-electron ions and atoms in the presence of quantum chaos” Date 13

  11. Tracing electron-ion recombination in nanoplasmas produced by extreme-ultraviolet irradiation of rare-gas clusters.

    Science.gov (United States)

    Schütte, B; Campi, F; Arbeiter, M; Fennel, Th; Vrakking, M J J; Rouzée, A

    2014-06-27

    We investigate electron-ion recombination in nanoplasmas produced by the ionization of rare-gas clusters with intense femtosecond extreme-ultraviolet (XUV) pulses. The relaxation dynamics following XUV irradiation is studied using time-delayed 790-nm pulses, revealing the generation of a large number of excited atoms resulting from electron-ion recombination. In medium-sized Ar-Xe clusters, these atoms are preferentially created in the Xe core within 10 ps after the cluster ionization. The ionization of excited atoms serves as a sensitive probe for monitoring the cluster expansion dynamics up to the ns time scale.

  12. Coincidence gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Markovic, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-01-01

    Gamma-ray spectrometry with high-purity germanium (HPGe) detectors is often the technique of choice in an environmental radioactivity laboratory. When measuring environmental samples associated activities are usually low so an important parameter that describes the performance of the spectrometer...... for a nuclide of interest is the minimum detectable activity (MDA). There are many ways for lowering the MDAs in gamma spectrometry. Recently, developments of fast and compact digital acquisition systems have led to growing number of multiple HPGe detector spectrometers. In these applications all detected...

  13. Electron-ion and ion-ion reaction rate coefficients at low altitudes during a PCA event

    NARCIS (Netherlands)

    Larsen, T.R.; Jespersen, M.; Murdin, J.; Bowling, T.S.; Beek, H.F. van; Stevens, G.A.

    Based on experimental data from several ESRO PCA rocket flights some considerations are presented regarding the mean values of the electron-ion dissociative recombination coefficient (αd) and the ion-ion neutralization coefficient (αi). The estimates yield values for αd = 10−5 cm3 sec−1 for heights

  14. Statistical data filtration in neutron coincidence counting

    International Nuclear Information System (INIS)

    Beddingfield, D.H.; Menlove, H.O.

    1992-11-01

    We assessed the effectiveness of statistical data filtration to minimize the contribution of matrix materials in 200-ell drums to the nondestructive assay of plutonium. Those matrices were examined: polyethylene, concrete, aluminum, iron, cadmium, and lead. Statistical filtration of neutron coincidence data improved the low-end sensitivity of coincidence counters. Spurious data arising from electrical noise, matrix spallation, and geometric effects were smoothed in a predictable fashion by the statistical filter. The filter effectively lowers the minimum detectable mass limit that can be achieved for plutonium assay using passive neutron coincidence counting

  15. Progress on the design of the polarized Medium-energy Electron Ion Collider at JLAB

    Energy Technology Data Exchange (ETDEWEB)

    Lin, F.; Bogacz, A.; Brindza, P.; Camsonne, A.; Daly, E.; Derbenev, Ya. S.; Douglas, D.; Ent, R.; Gaskell, D.; Geng, R.; Grames, J.; Guo, J.; Harwood, L.; Hutton, A.; Jordan, K.; Kimber, A.; Krafft, G.; Li, R.; Michalski, T.; Morozov, V. S.; Nadel-Turonski, P.; /Jefferson Lab /Argonne /DESY /Moscow , Inst. Phys. Tech., Dolgoprydny /Dubna, JINR /Northern Illinois U. /Old Doominion U. /Novosibirsk, GOO Zaryad /SLAC /Texas A-M

    2015-07-14

    The Medium-energy Electron Ion Collider (MEIC) at JLab is designed to provide high luminosity and high polarization needed to reach new frontiers in the exploration of nuclear structure. The luminosity, exceeding 1033 cm-2s-1 in a broad range of the center-of-mass (CM) energy and maximum luminosity above 1034 cm-2s-1, is achieved by high-rate collisions of short small-emittance low-charge bunches made possible by high-energy electron cooling of the ion beam and synchrotron radiation damping of the electron beam. The polarization of light ion species (p, d, 3He) can be easily preserved and manipulated due to the unique figure-8 shape of the collider rings. A fully consistent set of parameters have been developed considering the balance of machine performance, required technical development and cost. This paper reports recent progress on the MEIC accelerator design including electron and ion complexes, integrated interaction region design, figure-8-ring-based electron and ion polarization schemes, RF/SRF systems and ERL-based high-energy electron cooling. Luminosity performance is also presented for the MEIC baseline design.

  16. Transverse-momentum-dependent parton distribution/fragmentation functions at an electron-ion collider

    International Nuclear Information System (INIS)

    Anselmino, M.; Avakian, H.; Chen, J.P.; Musch, B.; Prokudin, A.; Qiang, Y.; Sulkosky, V.; Zhang, Y.; Boer, D.; Bradamante, F.; Burkardt, M.; Cisbani, E.; Contalbrigo, M.; Crabb, D.; Dutta, D.; Gamberg, L.; Gao, H.; Huang, M.; Laskaris, G.; Ye, Q.; Ye, Q.J.; Zheng, W.; Hasch, D.; Rossi, P.; Huang, J.; Kang, Z.; Keppel, C.; Liang, Z.T.; Liu, M.X.; Makins, N.; Peng, J.C.; Mckeown, R.D.; Qian, X.; Metz, A.; Meziani, Z.E.; Soffer, J.; Zhou, J.; Qiu, J.W.; Schweitzer, P.; Wang, Y.; Xiao, B.; Yuan, F.; Zhan, X.

    2011-01-01

    We present a summary of a recent workshop held at Duke University on Partonic Transverse Momentum in Hadrons: Quark Spin-Orbit Correlations and Quark-Gluon Interactions. The transverse-momentum-dependent parton distribution functions (TMDs), parton-to-hadron fragmentation functions, and multi-parton correlation functions, were discussed extensively at the Duke workshop. In this paper, we summarize first the theoretical issues concerning the study of partonic structure of hadrons at a future electron-ion collider (EIC) with emphasis on the TMDs. We then present simulation results on experimental studies of TMDs through measurements of single-spin asymmetries (SSA) from semi-inclusive deep inelastic scattering (SIDIS) processes with an EIC, and discuss the requirement of the detector for SIDIS measurements. The dynamics of parton correlations in the nucleon is further explored via a study of SSA in D (anti D) production at large transverse momenta with the aim of accessing the unexplored tri-gluon correlation functions. The workshop participants identified the SSA measurements in SIDIS as a golden program to study TMDs in both the sea and valence quark regions and to study the role of gluons, with the Sivers asymmetry measurements as examples. Such measurements will lead to major advancement in our understanding of TMDs in the valence quark region, and more importantly also allow for the investigation of TMDs in the unexplored sea quark region along with a study of their evolution. (orig.)

  17. LEIC - A Polarized Low Energy Electron-ion Collider at Jefferson Lab

    International Nuclear Information System (INIS)

    A polarized electron-ion collider is envisioned as the future nuclear science program at JLab beyond the 12 GeV CEBAF. Presently, a medium energy collider (MEIC) is set as an immediate goal with options for a future energy upgrade. A comprehensive design report for MEIC has been released recently. The MEIC facility could also accommodate electron and proton/ion collisions in a low CM energy range, covering proton energies from 10 to 25 GeV and ion energies with a similar magnetic rigidity, for additional science reach. In this paper, we present a conceptual design of this low energy collider, LEIC, showing its luminosity can reach above 10 33 cm -2 s -1 . The design specifies that the large booster of the MEIC is converted to a low energy ion collider ring with an interaction region and an electron cooler integrated into it. The design provides options for either sharing the detector with the MEIC or a dedicated low energy detector in a third collision point, with advantages of either a minimum cost or extra detection parallel to the MEIC operation, respectively. The LEIC could be positioned as the first and low cost phase of a multi-stage approach to realize the full MEIC

  18. Fluid aspects of electron streaming instability in electron-ion plasmas

    International Nuclear Information System (INIS)

    Jao, C.-S.; Hau, L.-N.

    2014-01-01

    Electrons streaming in a background electron and ion plasma may lead to the formation of electrostatic solitary wave (ESW) and hole structure which have been observed in various space plasma environments. Past studies on the formation of ESW are mostly based on the particle simulations due to the necessity of incorporating particle's trapping effects. In this study, the fluid aspects and thermodynamics of streaming instabilities in electron-ion plasmas including bi-streaming and bump-on-tail instabilities are addressed based on the comparison between fluid theory and the results from particle-in-cell simulations. The energy closure adopted in the fluid model is the polytropic law of d(pρ −γ )/dt=0 with γ being a free parameter. Two unstable modes are identified for the bump-on-tail instability and the growth rates as well as the dispersion relation of the streaming instabilities derived from the linear theory are found to be in good agreement with the particle simulations for both bi-streaming and bump-on-tail instabilities. At the nonlinear saturation, 70% of the electrons are trapped inside the potential well for the drift velocity being 20 times of the thermal velocity and the pρ −γ value is significantly increased. Effects of ion to electron mass ratio on the linear fluid theory and nonlinear simulations are also examined

  19. Probing Sea Quarks and Gluons: The Electron-Ion Collider Project

    Directory of Open Access Journals (Sweden)

    Horn Tanja

    2014-03-01

    Full Text Available The 21st century holds great promise for reaching a new era for unlocking the mysteries of the structure of the atomic nucleus and the nucleons inside it governed by the theory of strong interactions (QCD. In particular, much remains to be learned about the dynamical basis of the structure of hadrons and nuclei in terms of the fundamental quarks and gluons. One of the main goals of existing and nearly completed facilities is to map out the spin flavor structure of the nucleons in the valence region. A future Electron-Ion Collider (EIC would be the world’s first polarized electron-proton collider, and the world’s first e-A collider, and would seek the QCD foundation of nucleons and nuclei in terms of the sea quarks and gluons, matching to these valence quark studies. The EIC will provide a versatile range of kinematics and beam polarization, as well as beam species, to allow for mapping the spin and spatial structure of the quark sea and gluons, to discover the collective effects of gluons in atomic nuclei, and to understand the emergence of hadronic matter from color charge.

  20. Design Studies of High-Luminosity Ring-Ring Electron-Ion Collider at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Bogacz, Alex; Bogacz, Slawomir; Bogacz, Alex; Bogacz, Slawomir; Brindza, Paul; Bruell, Antje; Derbenev, Yaroslav; Ent, Rolf; Krafft, Geoffrey; Merminga, Nikolitsa; Musson, John; Wojtsekhowski, Bogdan; Yunn, Byung; Zhang, Yuhong; Qiang, Ji; Li, Rui

    2008-06-01

    An electron-ion collider of a center-of-mass energy up to 90 GeV at luminosity up to 1035 cm-2s-1 with both beams highly polarized is essential for exploring the new QCD frontier of strong color fields in nuclear and precisely imaging the sea-quarks and gluons in the nucleon. A conceptual design of a ring-ring collider based on CEBAF (ELIC) with energies up to 9 GeV for electrons/positrons and up to 225 GeV for protons and 100 GeV/u for ions has been proposed to fulfill the science desire and to serve as the next step for CEBAF after the planned 12 GeV energy upgrade of the fixed target program. Here, we summarize recent design progress for the ELIC complex with four interaction points (IP); including interaction region optics with chromatic aberration compensation scheme and complete lattices for the Figure-8 collider rings. Further optimization of crab crossing angles at the IPs, simulations of beam-beam interactions, and electron polarization in the Figure-8 ring and its matching at

  1. Electron Ion Collider: The Next QCD Frontier - Understanding the glue that binds us all

    CERN Document Server

    Accardi, A.; Anselmino, M.; Armesto, N.; Aschenauer, E.C.; Bacchetta, A.; Boer, D.; Brooks, W.K.; Burton, T.; Chang, N.B.; Deng, W.T.; Deshpande, A.; Diehl, M.; Dumitru, A.; Dupré, R.; Ent, R.; Fazio, S.; Gao, H.; Guzey, V.; Hakobyan, H.; Hao, Y.; Hasch, D.; Holt, R.; Horn, T.; Huang, M.; Hutton, A.; Hyde, C.; Jalilian-Marian, J.; Klein, S.; Kopeliovich, B.; Kovchegov, Y.; Kumar, K.; Kumerički, K.; Lamont, M.A.C.; Lappi, T.; Lee, J.H.; Lee, Y.; Levin, E.M.; Lin, F.L.; Litvinenko, V.; Ludlam, T.W.; Marquet, C.; Meziani, Z.E.; McKeown, R.; Metz, A.; Milner, R.; Morozov, V.S.; Mueller, A.H.; Müller, B.; Müller, Dieter; Nadel-Turonski, P.; Paukkunen, H.; Prokudin, A.; Ptitsyn, V.; Qian, X.; Qiu, J.W.; Ramsey-Musolf, M.; Roser, T.; Sabatié, F.; Sassot, R.; Schnell, G.; Schweitzer, P.; Sichtermann, E.; Stratmann, M.; Strikman, M.; Sullivan, M.; Taneja, S.; Toll, T.; Trbojevic, D.; Ullrich, T.; Venugopalan, R.; Vigdor, S.; Vogelsang, W.; Weiss, C.; Xiao, B.W.; Yuan, F.; Zhang, Y.H.; Zheng, L.

    2016-01-01

    This White Paper presents the science case of an Electron-Ion Collider (EIC), focused on the structure and interactions of gluon-dominated matter, with the intent to articulate it to the broader nuclear science community. It was commissioned by the managements of Brookhaven National Laboratory (BNL) and Thomas Jefferson National Accelerator Facility (JLab) with the objective of presenting a summary of scientific opportunities and goals of the EIC as a follow-up to the 2007 NSAC Long Range plan. This document is a culmination of a community-wide effort in nuclear science following a series of workshops on EIC physics and, in particular, the focused ten-week program on "Gluons and quark sea at high energies" at the Institute for Nuclear Theory in Fall 2010. It contains a brief description of a few golden physics measurements along with accelerator and detector concepts required to achieve them, and it benefited from inputs from the users' communities of BNL and JLab. This White Paper offers the promise to prope...

  2. Probing Sea Quarks and Gluons: The Electron-Ion Collider Project

    Science.gov (United States)

    Horn, Tanja

    2014-03-01

    The 21st century holds great promise for reaching a new era for unlocking the mysteries of the structure of the atomic nucleus and the nucleons inside it governed by the theory of strong interactions (QCD). In particular, much remains to be learned about the dynamical basis of the structure of hadrons and nuclei in terms of the fundamental quarks and gluons. One of the main goals of existing and nearly completed facilities is to map out the spin flavor structure of the nucleons in the valence region. A future Electron-Ion Collider (EIC) would be the world's first polarized electron-proton collider, and the world's first e-A collider, and would seek the QCD foundation of nucleons and nuclei in terms of the sea quarks and gluons, matching to these valence quark studies. The EIC will provide a versatile range of kinematics and beam polarization, as well as beam species, to allow for mapping the spin and spatial structure of the quark sea and gluons, to discover the collective effects of gluons in atomic nuclei, and to understand the emergence of hadronic matter from color charge.

  3. Pre-Town Meeting on spin physics at an Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Aschenauer, Elke-Caroline; Bland, Leslie; Huang, Jin; Tarasov, Andrey [Brookhaven National Laboratory, Physics Department, Upton, NY (United States); Balitsky, Ian; Radyushkin, Anatoly [Old Dominion University, Physics Department, Norfolk, VA (United States); Jefferson Lab, Newport News, VA (United States); Brodsky, Stanley J. [Stanford University, SLAC National Accelerator Laboratory, Stanford, CA (United States); Burkardt, Matthias [New Mexico State University, Department of Physics, Las Cruces, NM (United States); Burkert, Volker; Chen, Jian-Ping; Kubarovsky, Valery; Melnitchouk, Wally; Qiu, Jian-Wei; Richards, David [Jefferson Lab, Newport News, VA (United States); Deshpande, Abhay [Brookhaven National Laboratory, RIKEN BNL Research Center, Upton, NY (United States); Stony Brook University, SUNY, Department of Physics and Astronomy, Stony Brook, NY (United States); Diehl, Markus [Deutsches Elektronen-Synchroton DESY, Hamburg (Germany); Gamberg, Leonard [Penn State University-Berks, Division of Science, Reading, PA (United States); Grosse Perdekamp, Matthias [University of Illinois at Urbana-Champaign, Urbana, IL (United States); Hyde, Charles [Old Dominion University, Physics Department, Norfolk, VA (United States); Ji, Xiangdong [Shanghai Jiao Tong University, INPAC, Department of Physics, and Shanghai Key Lab for Particle Physics and Cosmology, Shanghai (China); Peking University, Center for High-Energy Physics, Beijing (China); University of Maryland, Maryland Center for Fundamental Physics, College Park, MD (United States); Jiang, Xiaodong; Liu, Ming [Los Alamos National Laboratory, Los Alamos, NM (United States); Kang, Zhong-Bo [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); University of California, Mani L. Bhaumik Institute for Theoretical Physics, Los Angeles, CA (United States); Lajoie, John [Iowa State University, Ames, IA (United States); Liu, Keh-Fei [University of Kentucky, Dept. of Physics and Astronomy Center for Computational Sciences, Lexington, KY (United States); Liuti, Simonetta [University of Virginia, Department of Physics, Charlottesville, VA (United States); Mulders, Piet [VU University Amsterdam, Nikhef and Department of Physics and Astronomy, Amsterdam (Netherlands); Prokudin, Alexei [Jefferson Lab, Newport News, VA (United States); Penn State University-Berks, Division of Science, Reading, PA (United States); Sichtermann, Ernst; Yuan, Feng [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Stratmann, Marco; Vogelsang, Werner [Tuebingen University, Institute for Theoretical Physics, Tuebingen (Germany)

    2017-04-15

    A polarized ep/eA collider (Electron-Ion Collider, or EIC), with polarized proton and light-ion beams and unpolarized heavy-ion beams with a variable center-of-mass energy √(s) ∝ 20 to ∝ 100 GeV (upgradable to ∝ 150 GeV) and a luminosity up to ∝ 10{sup 34} cm{sup -2}s{sup -1}, would be uniquely suited to address several outstanding questions of Quantum Chromodynamics, and thereby lead to new qualitative and quantitative information on the microscopic structure of hadrons and nuclei. During this meeting at Jefferson Lab we addressed recent theoretical and experimental developments in the spin and the three-dimensional structure of the nucleon (sea quark and gluon spatial distributions, orbital motion, polarization, and their correlations). This mini-review contains a short update on progress in these areas since the EIC White paper (A. Accardi et al., Eur. Phys. J. A 52, 268 (2016)). (orig.)

  4. High-performance DIRC detector for the future Electron Ion Collider experiment

    Science.gov (United States)

    Kalicy, G.; Allison, L.; Cao, T.; Dzhygadlo, R.; Horn, T.; Hyde, C.; Ilieva, Y.; Nadel-Turonski, P.; Park, K.; Peters, K.; Schwarz, C.; Schwiening, J.; Stevens, J.; Xi, W.; Zorn, C.

    2016-07-01

    A radially-compact subsystem providing particle identification (e/π, π/K, K/p) over a wide momentum range is an essential requirement for the central detector of an Electron-Ion Collider (EIC). With a radial size of only a few cm, a detector based on Detection of Internally Reflected Cherenkov light (DIRC) principle is a very attractive solution. The R&D undertaken by the EIC PID consortium achieved the goal of showing feasibility of a high-performance DIRC that would extend the momentum coverage well beyond state-of-the-art allowing 3σ separation of π/K up to 6 GeV/c, e/K up to 1.8 GeV/c and p/K up to 10 GeV/c. A key component to reach such a performance is a special 3-layer spherical compound lens. This article describes the status of the design and R&D for the DIRC at EIC detector, with a focus on the detailed Monte Carlo simulation results for the high-performance DIRC.

  5. Molecular Dynamics Simulation of Electron-Ion Temperature Relaxation in Dense Hydrogen: Electronic Quantum Effects

    Science.gov (United States)

    Ma, Qian; Dai, Jiayu; Zhao, Zengxiu

    2016-10-01

    The electron-ion temperature relaxation is an important non-equilibrium process in the generation of dense plasmas, particularly in Inertial Confinement Fusion. Classical molecular dynamics considers electrons as point charges, ignoring important quantum processes. We use an Electron Force Field (EFF) method to study the temperature relaxation processes, considering the nuclei as semi-classical point charges and assume electrons as Gaussian wave packets which includes the influences of the size and the radial motion of electrons. At the same time, a Pauli potential is used to describe the electronic exchange effect. At this stage, quantum effects such as exchange, tunneling can be included in this model. We compare the results from EFF and classical molecular dynamics, and find that the relaxation time is much longer with including quantum effects, which can be explained directly by the deference of collision cross sections between quantum particles and classical particles. Further, the final thermal temperature of electron and ion is different compared with classical results that the electron quantum effects cannot be neglected.

  6. New electron-ion-plasma equipment for modification of materials and products surface

    International Nuclear Information System (INIS)

    Koval', N.N.

    2013-01-01

    Electron-ion-plasma treatment of materials and products, including surface clearing and activation, formation surface layers with changed chemical and phase structure, increased hardness and corrosion resistance; deposition of various functional coatings, has received a wide distribution in a science and industry. Widespread methods of ion-plasma modification of material and product surfaces are ion etching and activation, ion-plasma nitriding, arc or magnetron deposition of functional coatings, including nanostructured. The combination of above methods of surface modification allows essentially to improve exploitation properties of treated products and to optimize the characteristics of modified surfaces for concrete final requirements. For the purpose of a combination of various methods of ion-plasma treatment in a single work cycle at Institute of High Current Electronics of SB RAS (IHCE SB RAS) specialized technological equipment 'DUET', 'TRIO' and 'QUADRO' and 'KVINTA' have been developed. This equipment allow generating uniform low-temperature gas plasma at pressures of (0.1-1) Pa with concentration of (10 9 -10 11 ) cm -3 in volume of (0.1-1) m 3 . In the installations consistent realization of several various operations of materials and products treatment in a single work cycle is possible. The operations are preliminary heating and degassing, ion clearing, etching and activation of materials and products surface by plasma of arc discharges; chemicothermal treatment (nitriding) for formation of diffusion layer on a surface of treated sample using plasma of nonself-sustained low-pressure arc discharge; deposition of single- or multilayered superhard (≥40 GPa) nanocrystalline coatings on the basis of pure metals or their compounds (nitrides, carbides, carbonitrides) by the arc plasma-assisted method. For realization of the modes all installations are equipped by original sources of gas and metal plasma. Besides, in

  7. A multipurpose electron-ion spectrometer for measurements with synchrotron radiation

    International Nuclear Information System (INIS)

    Huttula, Marko; Harkoma, Matti; Nommiste, Ergo; Aksela, Seppo

    2001-01-01

    A multipurpose system has been constructed for ion and electron measurements. The system can be used as a time of flight ion mass spectrometer, conventional electron spectrometer or threshold electron spectrometer. In the future it is planned to use the system as a coincidence spectrometer between ions and electrons with selected kinetic energies. The construction of the system is described and some measured spectra are presented

  8. Unified first principles description from warm dense matter to ideal ionized gas plasma: electron-ion collisions induced friction.

    Science.gov (United States)

    Dai, Jiayu; Hou, Yong; Yuan, Jianmin

    2010-06-18

    Electron-ion interactions are central to numerous phenomena in the warm dense matter (WDM) regime and at higher temperature. The electron-ion collisions induced friction at high temperature is introduced in the procedure of ab initio molecular dynamics using the Langevin equation based on density functional theory. In this framework, as a test for Fe and H up to 1000 eV, the equation of state and the transition of electronic structures of the materials with very wide density and temperature can be described, which covers a full range of WDM up to high energy density physics. A unified first principles description from condensed matter to ideal ionized gas plasma is constructed.

  9. Coupled electron-ion Monte Carlo simulation of hydrogen molecular crystals

    Science.gov (United States)

    Rillo, Giovanni; Morales, Miguel A.; Ceperley, David M.; Pierleoni, Carlo

    2018-03-01

    We performed simulations for solid molecular hydrogen at high pressures (250 GPa ≤ P ≤ 500 GPa) along two isotherms at T = 200 K (phase III) and at T = 414 K (phase IV). At T = 200 K, we considered likely candidates for phase III, the C2c and Cmca12 structures, while at T = 414 K in phase IV, we studied the Pc48 structure. We employed both Coupled Electron-Ion Monte Carlo (CEIMC) and Path Integral Molecular Dynamics (PIMD). The latter is based on Density Functional Theory (DFT) with the van der Waals approximation (vdW-DF). The comparison between the two methods allows us to address the question of the accuracy of the exchange-correlation approximation of DFT for thermal and quantum protons without recurring to perturbation theories. In general, we find that atomic and molecular fluctuations in PIMD are larger than in CEIMC which suggests that the potential energy surface from vdW-DF is less structured than the one from quantum Monte Carlo. We find qualitatively different behaviors for systems prepared in the C2c structure for increasing pressure. Within PIMD, the C2c structure is dynamically partially stable for P ≤ 250 GPa only: it retains the symmetry of the molecular centers but not the molecular orientation; at intermediate pressures, it develops layered structures like Pbcn or Ibam and transforms to the metallic Cmca-4 structure at P ≥ 450 GPa. Instead, within CEIMC, the C2c structure is found to be dynamically stable at least up to 450 GPa; at increasing pressure, the molecular bond length increases and the nuclear correlation decreases. For the other two structures, the two methods are in qualitative agreement although quantitative differences remain. We discuss various structural properties and the electrical conductivity. We find that these structures become conducting around 350 GPa but the metallic Drude-like behavior is reached only at around 500 GPa, consistent with recent experimental claims.

  10. Relativistic, QED and nuclear effects in highly charged ions revealed by resonant electron-ion recombination in storage rings

    OpenAIRE

    Schippers, Stefan

    2008-01-01

    Dielectronic recombination (DR) of few-electron ions has evolved into a sensitive spectroscopic tool for highly charged ions. This is due to technological advances in electron-beam preparation and ion-beam cooling techniques at heavy-ion storage rings. Recent experiments prove unambiguously that DR collision spectroscopy has become sensitive to 2nd order QED and to nuclear effects. This review discusses the most recent developments in high-resolution spectroscopy of low-energy DR resonances, ...

  11. Recent Progress on Design Studies of High-Luminosity Ring-Ring Electron-Ion Collider at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y; Bruell, A; Chevtsov, P; Derbenev, Y S; Ent, R; Krafft, G A; Li, R; Merminga, L

    2009-05-01

    The conceptual design of a ring-ring electron-ion collider based on CEBAF has been continuously optimized to cover a wide center-of-mass energy region and to achieve high luminosity and polarization to support next generation nuclear science programs. Here, we summarize the recent design improvements and R&D progress on interaction region optics with chromatic aberration compensation, matching and tracking of electron polarization in the Figure-8 ring, beam-beam simulations and ion beam cooling studies.

  12. Numerical Simulation of Beam-Beam Effects in the Proposed Electron-Ion Colider at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Balsa Terzic, Yuhong Zhang

    2010-05-01

    One key limiting factor to a collider luminosity is beam-beam interactions which usually can cause serious emittance growth of colliding beams and fast reduction of luminosity. Such nonlinear collective beam effect can be a very serious design challenge when the machine parameters are pushed into a new regime. In this paper, we present simulation studies of the beam-beam effect for a medium energy ring-ring electron-ion collider based on CEBAF.

  13. Quantifying radionuclide signatures from a γ–γ coincidence system

    International Nuclear Information System (INIS)

    Britton, Richard; Jackson, Mark J.; Davies, Ashley V.

    2015-01-01

    A method for quantifying gamma coincidence signatures has been developed, and tested in conjunction with a high-efficiency multi-detector system to quickly identify trace amounts of radioactive material. The γ–γ system utilises fully digital electronics and list-mode acquisition to time–stamp each event, allowing coincidence matrices to be easily produced alongside typical ‘singles’ spectra. To quantify the coincidence signatures a software package has been developed to calculate efficiency and cascade summing corrected branching ratios. This utilises ENSDF records as an input, and can be fully automated, allowing the user to quickly and easily create/update a coincidence library that contains all possible γ and conversion electron cascades, associated cascade emission probabilities, and true-coincidence summing corrected γ cascade detection probabilities. It is also fully searchable by energy, nuclide, coincidence pair, γ multiplicity, cascade probability and half-life of the cascade. The probabilities calculated were tested using measurements performed on the γ–γ system, and found to provide accurate results for the nuclides investigated. Given the flexibility of the method, (it only relies on evaluated nuclear data, and accurate efficiency characterisations), the software can now be utilised for a variety of systems, quickly and easily calculating coincidence signature probabilities. - Highlights: • Monte-Carlo based software developed to easily create/update a coincidence signal library for environmental radionuclides. • Coincidence library utilised to accurately quantify gamma coincidence signatures. • All coincidence signature probabilities are corrected for cascade summing, conversion electron emission and pair production. • Key CTBTO relevant radionuclides have been tested to verify the calculated correction factors. • Accurately quantifying coincidence signals during routine analysis will allow dramatically improved detection

  14. Quintessence, Cosmic Coincidence, and the Cosmological Constant

    International Nuclear Information System (INIS)

    Zlatev, I.; Wang, L.; Steinhardt, P.J.; Steinhardt, P.J.

    1999-01-01

    Recent observations suggest that a large fraction of the energy density of the Universe has negative pressure. One explanation is vacuum energy density; another is quintessence in the form of a scalar field slowly evolving down a potential. In either case, a key problem is to explain why the energy density nearly coincides with the matter density today. The densities decrease at different rates as the Universe expands, so coincidence today appears to require that their ratio be set to a specific, infinitesimal value in the early Universe. In this paper, we introduce the notion of a open-quotes tracker field,close quotes a form of quintessence, and show how it may explain the coincidence, adding new motivation for the quintessence scenario. copyright 1999 The American Physical Society

  15. Coincidence-counting corrections for accidental coincidences, set dead time and intrinsic dead time

    International Nuclear Information System (INIS)

    Wyllie, H.A.

    1998-01-01

    An equation is derived for calculating the radioactivity of a source from the results of coincidence counting, taking into account dead-time losses and accidental coincidences. The corrections allow for the extension of the set dead time in the p channel by the intrinsic dead time. Experimental verification shows improvement over a previous equation. (author)

  16. Coincidence imaging system with electron optics

    Czech Academy of Sciences Publication Activity Database

    Kroupa, M.; Jakubek, J.; Krejčí, F.; Žemlička, J.; Horáček, Miroslav; Radlička, Tomáš; Vlček, Ivan

    2011-01-01

    Roč. 633, Supl. 1 (2011), S270-S273 ISSN 0168-9002 R&D Projects: GA AV ČR IAA100650803 Institutional research plan: CEZ:AV0Z20650511 Keywords : electron optics * coincidence Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.207, year: 2011

  17. Preliminary results of a neutron-gamma coincidence experiment

    International Nuclear Information System (INIS)

    Piercey, R.B.; Dunnam, F.E.; Muga, M.L.; Rester, A.C.; Ramayya, A.V.; Hamilton, J.H.; Eberth, J.; Zganjar, E.F.

    1984-01-01

    The recently completed neutron multiplicity detector dubbed PANDA (Pentagonal Annular Neutron Detector Array) is fully described later in this report. The new detector was recently used for the first time on-line at the Holifield Heavy Ion Research Facility to measure neutron-gamma coincidence in the 24 Mg( 58 Ni,xαypzn) reaction. The detector configuration for the experiment is shown. The PANDA was situated in the forward direction, coaxial to the beam line with five gamma-ray detectors placed at +/- 90 0 , +/- 135 0 , and 0 0 . 2 figures

  18. Multiplicity

    Science.gov (United States)

    1991-04-01

    Virginia, 388 U.S. 1 (1967)(criminal statute prohibiting interracial marriages held unconstitutional violation of the Equal Protection and Due Process...such sentences does not violate the Constitution."°2 7 In effect , the double jeopardy protection from multiple punishments is coextensive with...unaware of what it accomplished . . . . In effect , the Blockburger test establishes a presumption of legislative intent: if each of two statutes

  19. Relativistic, QED and nuclear effects in highly charged ions revealed by resonant electron-ion recombination in storage rings

    International Nuclear Information System (INIS)

    Schippers, Stefan

    2009-01-01

    Dielectronic recombination (DR) of few-electron ions has evolved into a sensitive spectroscopic tool for highly charged ions. This is due to technological advances in electron-beam preparation and ion beam cooling techniques at heavy-ion storage rings. Recent experiments prove unambiguously that DR collision spectroscopy has become sensitive to 2nd order QED and to nuclear effects. This review discusses the most recent developments in high-resolution spectroscopy of low-energy DR resonances, experimental studies of KLL DR of very heavy hydrogen like ions, isotope shift measurements of DR resonances, and the experimental determination of hyperfine induced decay rates in divalent ions utilizing DR.

  20. Development of coincidence processing module for PEM

    International Nuclear Information System (INIS)

    Feng Baotong; Shuai Lei; Li Ke

    2011-01-01

    For the breast cancer diagnosis and therapy, a prototype of positron emission mammography (PEM) was developed in Institute of High Energy Physics, Chinese Academy of Sciences. In this paper, the design of coincidence processing module (CPM) for this PEM was presented. Both the hardware architecture and the software logic were introduced. In this design, the CPM used the Rocket IO fast interface in FPGA and fiber technology to acquire the preprocessed data from the continuous sampling module (CSM) and then selected the valid event with the coincidence timing window method, which was performed in the FPGA on the daughter board. The CPM transmits the processed data to host computer via gigabit Ethernet. The whole system was controlled by CAN bus. The primary tests indicate that the performance of this design is good. (authors)

  1. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  2. Improved coincidence rejection for silicon drift detectors

    Science.gov (United States)

    Mott, Richard B.

    2010-12-01

    The high count rates possible with silicon drift detectors (SDDs) raise the importance of coincidence ("pile-up") rejection in the pulse processor. Detection efficiency for close coincidence is energy dependent, with resolving times increasing sharply when at least one X-ray of the pair is below 1 keV. Traditional pile-up detection for low energies is done by applying a width test to the output of a shaping filter. SDDs have varying rise times at the preamplifier output due to the expansion of the charge cloud with drift path length, which limits the effectiveness of pulse width testing. Novel digital methods have been developed, which are largely immune to variations in rise time and significantly improve pulse-pair resolving times. Digital pulse processor filter parameters must take resolving times into account to achieve good sum peak position and shape for optimum software removal of sum peak artifacts during spectrum post-processing.

  3. Coincident-inclusive electrofission angular correlations

    International Nuclear Information System (INIS)

    Arruda Neto, J.D.T.

    1983-08-01

    A method for the joint analysis of coincident and inclusive electrofission data, in order to minimize effects of the model dependence of data interpretation, is developed. Explicit calculations of the (e,e'f) angular correlations are presented. The potentialities of the method to the study of sub- and near-barrier properties of the fission process, and to the study of the giant resonances fission mode, are discussed. (Author) [pt

  4. Timing coincidence studies with fast photomultipliers

    International Nuclear Information System (INIS)

    Raoof, M.A.; Raoof, S.A.

    1981-01-01

    The time response of RCA C70045D photomultipliers was studied using a subnanosecond light flasher. The tubes, which have an output rise time of approximately 0.5 ns, were used in coincidence to study the variations in the fwhm of the time spectrum over a certain dynamic range of pulse amplitudes for both leading edge and constant fraction discrimination. A comparison has also been made for the measured time resolutions with some of the other fast photomultipliers. (orig.)

  5. Multi-gamma windows coincidence method

    International Nuclear Information System (INIS)

    Liu Yunpeng

    1998-10-01

    In 4πβ-γ coincidence measurement of radioactivity, efficiency extrapolation method has been applied for a long time. According to the principle developed by P. J. Campion, usually a single gamma window is selected, and also an useful assumption is introduced that efficiency of individual β-branch are linearly related to one another, resulting in a simply linear efficiency function. Generally, the extrapolation curve is not linear so in practice an unspecified efficiency function which is usually defined simply as a polynomial in N c /N γ is introduced. Because of the unspecification of the efficiency function, systematic errors may arise theoretically from which the polynominal function is either inaccurate or unsuitable for extrapolation. To solve this problem, a new method, which is called multi-gamma windows coincidence method is proposed, and a new linear extrapolation equation based on average β efficiency is strictly derived from the basic coincidence equations with the least approximation. Theoretically, this method is applicable to any simple or complex decay (except pure β decay and some decay with long life metastable energy level) with minimum systematic errors

  6. The Nielsen Coincidence Number of Maps into Tori. | Jezierski ...

    African Journals Online (AJOL)

    ... of connected components of the coincidence set of a pair of maps between two tori (possibly of different dimensions). Mathematics Subject Classification (1991): 55M20 Keywords: coincidence index, coincidence Nielsen number, fixed points and coincidences tori, Nielsen Quaestiones Mathematicae 24(2) 2001, 217-223 ...

  7. Cochlear spike synchronization and neuron coincidence detection model

    Science.gov (United States)

    Bader, Rolf

    2018-02-01

    Coincidence detection of a spike pattern fed from the cochlea into a single neuron is investigated using a physical Finite-Difference model of the cochlea and a physiologically motivated neuron model. Previous studies have shown experimental evidence of increased spike synchronization in the nucleus cochlearis and the trapezoid body [Joris et al., J. Neurophysiol. 71(3), 1022-1036 and 1037-1051 (1994)] and models show tone partial phase synchronization at the transition from mechanical waves on the basilar membrane into spike patterns [Ch. F. Babbs, J. Biophys. 2011, 435135]. Still the traveling speed of waves on the basilar membrane cause a frequency-dependent time delay of simultaneously incoming sound wavefronts up to 10 ms. The present model shows nearly perfect synchronization of multiple spike inputs as neuron outputs with interspike intervals (ISI) at the periodicity of the incoming sound for frequencies from about 30 to 300 Hz for two different amounts of afferent nerve fiber neuron inputs. Coincidence detection serves here as a fusion of multiple inputs into one single event enhancing pitch periodicity detection for low frequencies, impulse detection, or increased sound or speech intelligibility due to dereverberation.

  8. Imaging photoelectron photoion coincidence spectroscopy with velocity focusing electron optics

    International Nuclear Information System (INIS)

    Bodi, Andras; Johnson, Melanie; Gerber, Thomas; Gengeliczki, Zsolt; Sztaray, Balint; Baer, Tomas

    2009-01-01

    An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or thermal gas-phase sample. Photoelectrons are velocity focused, with better than 1 meV resolution for threshold electrons, and also act as start signal for the ion time-of-flight analysis. The ions are accelerated in a relatively low, 40-80 V cm -1 field, which enables the direct measurement of rate constants in the 10 3 -10 7 s -1 range. All electron and ion events are recorded in a triggerless multiple-start/multiple-stop setup, which makes it possible to carry out coincidence experiments at >100 kHz event frequencies. As examples, the threshold photoelectron spectrum of the argon dimer and the breakdown diagrams for hydrogen atom loss in room temperature methane and the chlorine atom loss in cold chlorobenzene are shown and discussed.

  9. A Real Time Digital Coincidence Processor for positron emission tomography

    International Nuclear Information System (INIS)

    Dent, H.M.; Jones, W.F.; Casey, M.E.

    1986-01-01

    A Real Time Digital Coincidence Processor has been developed for use in the Positron Emission Tomograph (PET) ECAT scanners manufactured by Computer Technology and Imaging, Inc. (CTI). The primary functions of the Coincidence Processor include: receive from the BGO detector modules serial data, which includes timing information and detector identification; process the received data to form coincidence detector pairs; and present the coincidence pair data to a Real Time Sorter. The primary design emphasis was placed on the Coincidence Processor being able to process the detector data into coincidence pairs at real time rates. This paper briefly describes the Coincidence Processor and some of the considerations that went into its design

  10. A method for coincidence timing resolution enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Ermis, E. E., E-mail: elermis@hotmail.com; Celiktas, C. [Faculty of Science, Physics Department, Ege University, 35100 Bornova, Izmir (Turkey); Pilicer, E. [Faculty of Arts and Science, Physics Department, Uludag University, Gorukle, Bursa (Turkey)

    2016-05-15

    A method including the coincidence time resolution improvement for a TOF/positron emission tomography system was suggested. The spectrometer for this aim was composed of two NaI(Tl) and two plastic scintillation detectors. Experimental results were supported by FLUKA Monte Carlo simulation program by constructing the detector setup in software medium. Present experimental results verified our previous results and conclusions obtained from the suggested method. It was concluded that better resolutions would help the improvement not only on the TOF gain but also on the spatial resolution, leading to better images and helping the Physician in his/her diagnosis and treatment.

  11. Coincidence logic modules for criticality alarming

    International Nuclear Information System (INIS)

    Schaief, C.C. III.

    1977-04-01

    A coincidence Logic Module and a companion contact closure Relay Module utilizing the NIM Standard have been developed for criticality alarming. The units provide an ALARM whenever two or more out of N detectors become activated. In addition, an ALERT is generated whenever one or more detectors is activated or when certain electronic component failures occur. The number of detector inputs (N) can be expanded in groups of six by adding modules. Serial and parallel redundancy were used to reduce the probability of system failure

  12. Cosmical coincidences and the Dirac-cosmos

    Energy Technology Data Exchange (ETDEWEB)

    Treder, H.J.

    1984-09-01

    The cosmical coincidences given by the relations between macro- and microphysical quantities suggest a manifold of small bangs and not universal big bang in the evolution of the meta-galaxy. An approximative model of such universe may be the Dirac-cosmos. The hypothesis is discussed that the small bangs are the relations of the super-galaxies. In this cases there are to be found two different values of the Hubble-parameter according to the differently evolutionary scenaries for the meta-galaxis and for super-galaxies.

  13. Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting

    CERN Document Server

    Bourva, L C A

    1999-01-01

    The general purpose neutron-photon-electron Monte Carlo N-Particle code, MCNP sup T sup M , has been used to simulate the neutronic characteristics of the on-site laboratory passive neutron coincidence counter to be installed, under Euratom Safeguards Directorate supervision, at the Sellafield reprocessing plant in Cumbria, UK. This detector is part of a series of nondestructive assay instruments to be installed for the accurate determination of the plutonium content of nuclear materials. The present work focuses on one aspect of this task, namely, the accurate calculation of the coincidence gate utilisation factor. This parameter is an important term in the interpretative model used to analyse the passive neutron coincidence count data acquired using pulse train deconvolution electronics based on the shift register technique. It accounts for the limited proportion of neutrons detected within the time interval for which the electronics gate is open. The Monte Carlo code MCF, presented in this work, represents...

  14. Excitation and ionization contributions to sum-rule Born cross sections for collisions of one-electron ions with atoms

    International Nuclear Information System (INIS)

    Gillespie, G.H.

    1978-01-01

    The contributions of bound-state excitations and continuum ionizations to the total inelastic (sum-rule) cross section are examined in Born approximation. The results of an investigation of this problem for the case of one-electron ions colliding with neutral atoms are presented. Emphasis in this work is placed on the general features of these types of cross sections and on the relative contributions of excitation and ionization to the total Born cross section. In addition, extensive numerical results for the parameters which determine the cross sections for electron loss, and for excitation to bound states, are given for one-electron ions having atomic numbers up to 30 colliding with He, N, and Ar target atoms. It is shown that for the asymptotic (high-velocity) Born cross sections, excitation never contributes more than a certain fraction of the total sum-rule inelastic cross section, and this fraction has a bound which is determined by the dipole limit of the transition amplitudes for the incident ion. This bound is given by M/sub ex/ 2 /M/sub tot/ 2 , where M/sub tot/ 2 is the -1 energy moment of the dipole-oscillator-strength distribution and M/sub ex/ 2 is the contribution to this moment from transitions to bound excited states. This result is independent of the target atom involved in the collision. Since M/sub ex/ 2 /M/sub tot/ 2 does not depend on the atomic number for one-electron ions, this bound is also independent of the incident-ion atomic number in this case. As a consequence, ionization never contributes less to the sum-rule cross sections than the fraction (1-M/sub ex/ 2 /M/sub tot/ 2 ) = M/sub ion/ 2 /M/sub tot/ 2 . The more general problem, which involves multielectron ions (or atoms) colliding with atoms, is discussed from several viewpoints, and similar results are suggested for that case. In particular, separate upper bounds on the Born-excitation cross section, and lower bounds on the Born electron-loss cross section, are proposed

  15. Multiplicity Counting

    Energy Technology Data Exchange (ETDEWEB)

    Geist, William H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-01

    This set of slides begins by giving background and a review of neutron counting; three attributes of a verification item are discussed: 240Pueff mass; α, the ratio of (α,n) neutrons to spontaneous fission neutrons; and leakage multiplication. It then takes up neutron detector systems – theory & concepts (coincidence counting, moderation, die-away time); detector systems – some important details (deadtime, corrections); introduction to multiplicity counting; multiplicity electronics and example distributions; singles, doubles, and triples from measured multiplicity distributions; and the point model: multiplicity mathematics.

  16. Comparison of electron-ion energy transfer in dense plasmas obtained from numerical simulations and quantum kinetic theory

    Science.gov (United States)

    Vorberger, J.; Gericke, D. O.

    2014-03-01

    We evaluate various analytical models for the electron-ion energy transfer and compare the results to data from molecular dynamics (MD) simulations. The models tested include energy transfer via strong binary collisions, Landau-Spitzer rates with different choices for the cut-off parameters in the Coulomb logarithm, rates based on Fermi's golden rule (FGR) and theories taking coupled collective modes (CM) into account. In search of a model easy to apply, we first analyze different approximations of the FGR energy transfer rate. Then, we investigate several numerical studies using MD simulations and try to uncover CM effects in the data obtained. Most MD data published so far, except one study by Murillo et al. [23], show no distinct CM effects and, thus, can be interpreted within a FGR or binary collision approach. We show that this finding is related to the parameter regime, in particular the initial temperature difference, considered in these investigations.

  17. Fireball as the result of self-organization of an ensemble of diamagnetic electron-ion nanoparticles in molecular gas

    Energy Technology Data Exchange (ETDEWEB)

    Lopasov, V. P., E-mail: lopas@iao.ru [Russian Academy of Sciences, Zuev Institute for Atmospheric Optics, Siberian Branch (Russian Federation)

    2011-12-15

    The conditions for dissipative self-organization of a fireball (FB) is a molecular gas by means of a regular correction of an elastic collision of water and nitrogen molecules by the field of a coherent bi-harmonic light wave (BLW) are presented. The BWL field is generated due to conversion of energy of a linear lightning discharge into light energy. A FB consists of two components: an ensemble of optically active diamagnetic electron-ion nanoparticles and a standing wave of elliptical polarization (SWEP). It is shown that the FB lifetime depends on the energies accumulated by nanoparticles and the SWEP field and on the stability of self-oscillations of the energy between nanoparticles and SWEP.

  18. Simulation Studies of Beam-Beam Effects of a Ring-Ring Electron-Ion Collider Based on CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Yuhong Zhang,Ji Qiang

    2009-05-01

    The collective beam-beam effect can potentially cause a rapid growth of beam sizes and reduce the luminosity of a collider to an unacceptably low level. The ELIC, a proposed ultra high luminosity electron-ion collider based on CEBAF, employs high repetition rate crab crossing colliding beams with very small bunch transverse sizes and very short bunch lengths, and collides them at up to 4 interaction points with strong final focusing. All of these features can make the beam-beam effect challenging. In this paper, we present simulation studies of the beam-beam effect in ELIC using a self-consistent strong-strong beam-beam simulation code developed at Lawrence Berkeley National Laboratory. This simulation study is used for validating the ELIC design and for searching for an optimal parameter set.

  19. The Washington Large Area Time Coincidence Array

    Science.gov (United States)

    Gran, R.; Berns, H.G.; Buchli, M.; Burnett, T.H.; Edmon, P.; Gran, R.; Haff, T.; Lemagie; Muhs, E.; Wheel, G.; Wilkes, R.J.

    2003-07-01

    WALTA (WAshington Large-area Time-coincidence Array) aims to study ultra-high energy (> 1018 eV) cosmic rays (UHECR) by placing detector elements in Seattle area secondary scho ols, and linking their data acquisition systems to the University of Washington via a computer network. The goal of WALTA is to have teachers and students become active participants in forefront scientific project, while building a long term partnership between the scho ols and the university-based physics research community. Considerable progress has been made in recruiting and training teachers and equipping scho ol sites since the last ICRC, including development of a low-cost data acquisition card in collab oration with Fermilab and the University of Nebraska.

  20. Electron-ion attachment induced instability of dust acoustic waves in the presence of ionization in a charge varying collisional dusty plasma

    International Nuclear Information System (INIS)

    Ghosh, Samiran; Khan, Manoranjan

    2006-01-01

    Low frequency electrostatic dust acoustic wave (DAW) instability with a significant background pressure of neutrals has been investigated in a collisional dusty plasma incorporating the dust charge relaxation and electron-ion attachment (recombination) onto dust grains using a self consistent theory. A long wavelength mode is found to be unstable due to electron-ion attachment on to the dust grains. Applications to experimental observations of low frequency fluctuation and the relevance of these results to 'void' in a laboratory gas discharge dusty plasma are briefly discussed

  1. A multiplicity logic unit

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Zagorski, A.

    1981-01-01

    The logic diagram principle of operation and some details of the design of the multiplicity logic unit are presented. This unit was specially designed to fulfil the requirements of a multidetector arrangement for gamma-ray multiplicity measurements. The unit is equipped with 16 inputs controlled by a common coincidence gate. It delivers a linear output pulse with the height proportional to the multiplicity of coincidences and logic pulses corresponding to 0, 1, ... up to >= 5-fold coincidences. These last outputs are used to steer the routing unit working with the multichannel analyser. (orig.)

  2. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  3. Obesity and asthma: association or coincidence?

    Science.gov (United States)

    Camilo, Daniella Fernandes; Ribeiro, José Dirceu; Toro, Adyleia Dalbo Contrera; Baracat, Emilio Carlos Elias; Barros Filho, Antonio Azevedo

    2010-01-01

    Asthma and obesity are among the major causes of morbidity in childhood and adolescence. Early obesity increases the chances of chronic degenerative diseases in adults. Although the concomitance or both clinical situations are being demonstrated in various studies, the intrinsic mechanisms of this association are still very little known. Therefore, the objective of this article was to review the main studies on the association of obesity and asthma and check if there is a cause-effect relation between them. Systematic review based on indexed data bases MEDLINE (PubMed) and SciELO. Original articles (cross-sectional, case-control, and prospective studies) and meta-analysis published in the period that ranges from January 1998 to January 2008 were reviewed. Studies published in English, Spanish, and Portuguese were researched. Although there are various studies on growing prevalence of asthma and obesity, few of them establish cause-effect relations between them. Physiopathological mechanisms and factors involved in this process are still little known. Methodological rigor in future studies must seek for answers to better understand if there is association between asthma and obesity or if the relationship between both diseases is a coincidence.

  4. K-chameleon and the coincidence problem

    International Nuclear Information System (INIS)

    Wei Hao; Cai Ronggen

    2005-01-01

    In this paper we present a hybrid model of k-essence and chameleon, named as k-chameleon. In this model, due to the chameleon mechanism, the directly strong coupling between the k-chameleon field and matters (cold dark matters and baryons) is allowed. In the radiation-dominated epoch, the interaction between the k-chameleon field and background matters can be neglected; the behavior of the k-chameleon therefore is the same as that of the ordinary k-essence. After the onset of matter domination, the strong coupling between the k-chameleon and matters dramatically changes the result of the ordinary k-essence. We find that during the matter-dominated epoch, only two kinds of attractors may exist: one is the familiar K attractor and the other is a completely new, dubbed C attractor. Once the Universe is attracted into the C attractor, the fraction energy densities of the k-chameleon Ω φ and dust matter Ω m are fixed and comparable, and the Universe will undergo a power-law accelerated expansion. One can adjust the model so that the K attractor does not appear. Thus, the k-chameleon model provides a natural solution to the cosmological coincidence problem

  5. Determination of plutonium in nuclear fuels using the neutron coincidence method

    International Nuclear Information System (INIS)

    Boehnel, K.

    1978-03-01

    In assays for plutonium the neutron coincidence technique is often used. This method which is based on measuring spontaneous fission rates is examined both experimentally and theoretically. A novel coincidence unit is described which works in effect without deadtime and which therefore has advantages over the currently used design. For waste samples a principle for measurement is described which avoids space dependence effects by rotating the probe in an asymmetric detector. Formulae are developed for the statistical error and various effects of deadtimes are discussed. Further it is shown that neutron multiplication in the sample is an important source of errors, especially when the (α, n)-background is neglected. (author)

  6. R&D of a High-Performance DIRC Detector for a Future Electron-Ion Collider

    Science.gov (United States)

    Allison, Stacey Lee

    An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly flat focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

  7. A novel cell-scale bio-nanogenerator based on electron-ion interaction for fast light power conversion.

    Science.gov (United States)

    Li, Yu-Tao; Tian, He; Zhao, Hai-Ming; Jian, Mu-Qiang; Lv, Yu-Jia; Tian, Ye; Wang, Qian; Yang, Yi; Xiang, Yan; Zhang, Yingying; Ren, Tian-Ling

    2018-01-03

    Natural energy haversting devices serve as an alternative candidate for power supply in many micro-/nano-systems. However, traditional nanogenerators based on piezoelectricity or triboelectric power generation face challenges in terms of biocompatibility and stability in various biological systems. The bacteriorhodopsin (bR) protein in Halobacterium halobium is an ideal biocompatible material for photoelectric conversion. Conventional bR systems based on ion transport or enhanced light absorption layers have a limited light power conversion speed. On the other hand, bR-based biohybrid devices have a great potential for sensitive light power conversion as compared to conventional nanogenerators. Herein, we present a biohybrid nanogenerator made of bR and horizontally aligned-long carbon nanotubes (CNTs) with electron-ion interaction for the first time for sensitive light power conversion. The bR layer serves as the proton pump, whereas CNTs are utilized to enhance the photocurrent; thus, the photocurrent frequency response improves significantly because of the effect of the electron-ion interaction. The photocurrent shows a linear relationship with the intensity of light and can still obtain a stable signal at a light intensity of 0.03 mW cm -2 . With regard to the influence of the light on-off period, the photocurrent initially increases and then decreases with an increase in flickering frequency up to 360 Hz; this can be ascribed to the combinational influence of light switch speed and photocycle decay time. The photocurrent shows highest value (99 nA cm -2 ) at a frequency of about 50 Hz at a light intensity of 0.43 mW cm -2 , which matches well with the frequency standard of the electrical power supply system. Moreover, we found that a higher density of CNTs contributed to improve performance of the nanogenerators. Furthermore, a H + ion releasing model was proposed to interpret the operating mechanism of the biohybrid nanogenerator. The biohybrid nanogenerator

  8. R&D of a high-performance DIRC detector for a future electron-ion collider

    Energy Technology Data Exchange (ETDEWEB)

    Allison, Staceu L. [Old Dominion Univ., Norfolk, VA (United States)

    2017-08-01

    An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly at focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

  9. Molecular dynamics studies of electron-ion temperature equilibration in hydrogen plasmas within the coupled-mode regime.

    Science.gov (United States)

    Benedict, Lorin X; Surh, Michael P; Stanton, Liam G; Scullard, Christian R; Correa, Alfredo A; Castor, John I; Graziani, Frank R; Collins, Lee A; Čertík, Ondřej; Kress, Joel D; Murillo, Michael S

    2017-04-01

    We use classical molecular dynamics (MD) to study electron-ion temperature equilibration in two-component plasmas in regimes for which the presence of coupled collective modes has been predicted to substantively reduce the equilibration rate. Guided by previous kinetic theory work, we examine hydrogen plasmas at a density of n=10^{26}cm^{-3}, T_{i}=10^{5}K, and 10^{7}K

  10. Harmonic Kicker RF Cavity for the Jefferson Lab Electron-Ion Collider EM Simulation, Modification, and Measurements

    Science.gov (United States)

    Overstreet, Sarah; Wang, Haipeng

    2017-09-01

    An important step in the conceptual design for the future Jefferson Lab Electron-Ion Collider (JLEIC) is the development of supporting technologies for the Energy Recovery Linac (ERL) Electron Cooling Facility. The Harmonic Radiofrequency (RF) kicker cavity is one such device that is responsible for switching electron bunches in and out of the Circulator Cooling Ring (CCR) from and to the ERL, which is a critical part of the ion cooling process. Last year, a half scale prototype of the JLEIC harmonic RF kicker model was designed with resonant frequencies to support the summation of 5 odd harmonics (95.26 MHz, 285.78 MHz, 476.30 MHz, 666.82 MHz, and 857.35 MHz); however, the asymmetry of the kicker cavity gives rise to multipole components of the electric field at the electron-beam axis of the cavity. Previous attempts to symmetrize the electric field of this asymmetrical RF cavity have been unsuccessful. The aim of this study is to modify the existing prototype for a uniform electric field across the beam pathway so that the electron bunches will experience nearly zero beam current loading. In addition to this, we have driven the unmodified cavity with the harmonic sum and used the wire stretching method for an analysis of the multipole electric field components.

  11. Results from the magnetic electron ion spectrometer (MagEIS) instruments aboard the Van Allen Probes spacecraft

    Science.gov (United States)

    Fennell, Joseph; O'Brien, Paul; Roeder, James; Reeves, Geoffrey; Claudepierre, Seth; Clemmons, James; Spence, Harlan; Blake, Bernard

    The Magnetic Electron Ion Spectrometer (MagEIS) instruments aboard the Van Allen Probes Spacecraft (formerly RBSP) measure electrons and ions in the Earth's inner and outer radiation belts. The MagEIS instruments are part of the Energetic Particle, Composition, and Thermal Plasma Suite (ECT), which also includes the Relativistic Electron Proton Telescope (REPT) and the Helium Oxygen Proton Electron (HOPE) analyzer. MagEIS consists of four magnetic electron spectrometers aboard each of the two Van Allen Probes spacecraft that measure the differential fluxes, energies, and angular distributions of electrons from 20 keV to 4 MeV. The MagEIS suite also contains a silicon-detector telescope that measures the differential fluxes, energies, and angular distributions of protons from 60 keV to 20 MeV, and helium and oxygen ions above a hundred keV/AMU. We briefly describe the instrument design and measurement technique and present a set of results from the MagEIS observations, including ultra-low frequency (ULF) modulations of energetic electron flux, and observations of electron flux enhancements associated with the recent BARREL x-ray observations.

  12. Initial Results from the Magnetic Electron Ion Spectrometer (MagEIS) Instruments Aboard the Van Allen Probes Spacecraft

    Science.gov (United States)

    Claudepierre, S. G.; Blake, J. B.; Fennell, J. F.; Clemmons, J. H.; Roeder, J. L.; Spence, H. E.; Reeves, G. D.; Van Allen Probes ECT Team

    2013-05-01

    The Magnetic Electron Ion Spectrometer (MagEIS) instruments aboard the Van Allen Probes Spacecraft (formerly RBSP) measure electrons and ions in the Earth's inner and outer radiation belts. The MagEIS instruments are part of the Energetic Particle, Composition, and Thermal Plasma Suite (ECT), which also includes the Relativistic Electron Proton Telescope (REPT) and the Helium Oxygen Proton Electron (HOPE) analyzer. MagEIS consists of four magnetic electron spectrometers aboard each of the two Van Allen Probes spacecraft that measure the differential fluxes, energies, and angular distributions of electrons from 20 keV to 4 MeV. The MagEIS suite also contains a silicon-detector telescope that measures the differential fluxes, energies, and angular distributions of protons from 60 keV to 20 MeV, and helium and oxygen ions above a hundred keV/AMU. We briefly describe the instrument design and measurement technique and present a set of initial results from the MagEIS observations, including ultra-low frequency (ULF) modulations of energetic electron flux, and observations of electron flux enhancements associated with the recent BARREL x-ray observations.

  13. Validity of the independent-processes approximation for resonance structures in electron-ion scattering cross sections

    International Nuclear Information System (INIS)

    Badnell, N.R.; Pindzola, M.S.; Griffin, D.C.

    1991-01-01

    The total inelastic cross section for electron-ion scattering may be found in the independent-processes approximation by adding the resonant cross section to the nonresonant background cross section. We study the validity of this approximation for electron excitation of multiply charged ions. The resonant-excitation cross section is calculated independently using distorted waves for various Li-like and Na-like ions using (N+1)-electron atomic-structure methods previously developed for the calculation of dielectronic-recombination cross sections. To check the effects of interference between the two scattering processes, we also carry out detailed close-coupling calculations for the same atomic ions using the R-matrix method. For low ionization stages, interference effects manifest themselves sometimes as strong window features in the close-coupling cross section, which are not present in the independent-processes cross section. For higher ionization stages, however, the resonance features found in the independent-processes approximation are found to be in good agreement with the close-coupling results

  14. Structure of very heavy few-electron ions - new results from the heavy ion storage ring, ESR

    International Nuclear Information System (INIS)

    Mokler, P.H.; Stoehlker, T.; Kozhuharov, C.; Moshammer, R.; Rymuza, P.; Bosch, F.; Kandler, T.

    1993-08-01

    The heavy ion synchrotron/storage ring facility at GSI, SIS/ESR, provides intense beams of cooled, highly-charged ions up to naked uranium (U 92+ ). By electron capture during ion-atom collisions in the gas target of the ESR or by recombination at ion-electron encounters in the ''electron cooler'' excited states are populated. The detailed structure of very heavy one-, two- and three-electron ions is studied. The different mechanisms leading to the excited states are described, as well as the new experimental tools now available for a detailed spectroscopy of these interesting systems. Special emphasis is given to X-ray transitions to the groundstates in H- and He-like systems. For the heaviest species the groundstate Lambshift can now be probed on an accuracy level of better than 10% using solid-state X-ray detectors. Applying dispersive X-ray analyzing techniques, this accuracy will certainly be improved in future. However, utilizing the dielectronic resonances for a spectroscopy, the structure in Li-like heavy ions can already be probed now on the sub eV level. (orig.)

  15. Operations manual for the megachannel gamma-ray coincidence system

    International Nuclear Information System (INIS)

    Ruhter, W.

    1977-01-01

    To aid in the study of nuclear structures, a megachannel pulse-height coincidence analysis system on a PDP-8 computer was constructed. The system digitizes the energies of coincident gamma-rays and stores the resultant information on a moving-head disk. The system uses a minicomputer to sort and store gamma-gamma coincident information on line. The megachannel system and how to use it are described

  16. Digital gamma-gamma coincidence HPGe system for environmental analysis

    DEFF Research Database (Denmark)

    Markovic, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-01-01

    The performance of a new gamma-gamma coincidence spectrometer system for environmental samples analysis at the Center for Nuclear Technologies of the Technical University of Denmark (DTU) is reported. Nutech Coincidence Low Energy Germanium Sandwich (NUCLeGeS) system consists of two HPGe detector...... in a surface laboratory with a digital acquisition system used to collect the data in time-stamped list mode with 10. ns time resolution. The spectrometer is used in both anticoincidence and coincidence modes....

  17. Principle of coincidence method and application in activity measurement

    International Nuclear Information System (INIS)

    Li Mou; Dai Yihua; Ni Jianzhong

    2008-01-01

    The basic principle of coincidence method was discussed. The basic principle was generalized by analysing the actual example, and the condition in theory of coincidence method was brought forward. The cause of variation of efficiency curve and the effect of dead-time in activity measurement were explained using the above principle and condition. This principle of coincidence method provides the foundation in theory for activity measurement. (authors)

  18. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  19. Femto-second dynamics probed by resonant photoemission and coincidence techniques

    International Nuclear Information System (INIS)

    Miron, C.; Ceolin, D.; Morin, P.

    2004-01-01

    Full text: It is well known nowadays that inner-shell excitation induces very rich dynamics where nuclear motion and electronic decay compete on a very short time scale, like in the case of ultra-fast molecular dissociation. Since the st experimental evidence was given by P. Morin and I. Nenner in 1986 for HBr and until now, it was shown that it acted as a general phenomenon taking place in a large variety of molecular systems. A nice consequence of such a process was shown by Prof. Svensson's group in Sweden by resonant photoemission measurements of the decay of the O 1s → σ * core-excited state in O 2 : the Auger-Doppler effect. More recently, a Japanese group demonstrated that the Auger-Doppler effect may be employed as a probe of the Auger emission anisotropy. The present talk will mainly deal with the mechanisms of intra-molecular ultra-fast chemical reaction pathways induced by inner-shell excitation and probed by energy selected resonant Auger electron-ion coincidences (ES-RAEPICO) and resonant photoemission measurements. Such a reactive pathway could be revealed through the appearance of rearrangement products. The dynamics of such ultra-fast chemical reactions, if they occur, will be entirely governed by the competition between the nuclear motion in the core-excited state and electronic decay (Auger decay). Since the chemical reaction is able to occur only during the lifetime of the core-excited state, the Auger decay may be seen in this context as a chemical reaction inhibitor, which leads the excited system towards a different relaxation pathway. The measurement in coincidence of the kinetic energy of the ejected Auger electrons and of fragment ions is able to reveal in such a case the energetics and kinematics of the possible decay mechanisms. Moreover, the photon energy detuning with respect to the nominal core-excitation energy allows changing the energy of the reactants and influence the chemical dynamics on a femtosecond time scale

  20. Shift-register coincidence electronics system for thermal neutron counters

    International Nuclear Information System (INIS)

    Swansen, J.E.; Collinsworth, P.R.; Krick, M.S.

    1980-04-01

    An improved shift-register, coincidence-counting logic circuit, developed for use with thermal neutron well counters, is described in detail. A distinguishing feature of the circuit is its ability to operate usefully at neutron counting rates of several hundred kHz. A portable electronics package incorporating the new coincidence logic and support circuits is also described

  1. Coincidence of and collinearity between game theoretic solutions

    NARCIS (Netherlands)

    Driessen, Theo; Funaki, Y.

    1991-01-01

    The first part is the study of several conditions which are sufficient for the coincidence of the prenucleolus concept and the egalitarian nonseparable contribution (ENSC-) method. The main sufficient condition for the coincidence involved requires that the maximal excesses at the ENSC-solution are

  2. Identification of peaks in multidimensional coincidence {gamma}-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, Miroslav E-mail: fyzimiro@savba.sk; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-03-21

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector {gamma}-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges.

  3. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  4. An Inexpensive Coincidence Circuit for the Pasco Geiger Sensors

    CERN Document Server

    Fichera, F; Librizzi, F; Riggi, F

    2005-01-01

    A simple coincidence circuit was devised to carry out educational coincidence experiments involving the use of Geiger counters. The system was tested by commercially available Geiger sensors from PASCO, and is intended to be used in collaboration with high school students and teachers

  5. Recovery and normalization of triple coincidences in PET

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.; Herraiz, Joaquin L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Moore, Stephen C.; Sitek, Arkadiusz; Park, Mi-Ae [Division of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States); Udías, Jose M. [Grupo de Física Nuclear, Departamento de Física Atómica Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Vaquero, Juan J. [Departamento de Ingeniería Biomédica e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Leganés 28911 (Spain)

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the

  6. Introduction to Neutron Coincidence Counter Design Based on Boron-10

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Siciliano, Edward R.

    2012-01-22

    The Department of Energy Office of Nonproliferation Policy (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is ultimately to design, build and demonstrate a boron-lined proportional tube based alternative system in the configuration of a coincidence counter. This report, providing background information for this project, is the deliverable under Task 1 of the project.

  7. Software correction of scatter coincidence in positron CT

    International Nuclear Information System (INIS)

    Endo, M.; Iinuma, T.A.

    1984-01-01

    This paper describes a software correction of scatter coincidence in positron CT which is based on an estimation of scatter projections from true projections by an integral transform. Kernels for the integral transform are projected distributions of scatter coincidences for a line source at different positions in a water phantom and are calculated by Klein-Nishina's formula. True projections of any composite object can be determined from measured projections by iterative applications of the integral transform. The correction method was tested in computer simulations and phantom experiments with Positologica. The results showed that effects of scatter coincidence are not negligible in the quantitation of images, but the correction reduces them significantly. (orig.)

  8. Some target assay uncertainties for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Ensslin, N.; Langner, D.G.; Menlove, H.O.; Miller, M.C.; Russo, P.A.

    1990-01-01

    This paper provides some target assay uncertainties for passive neutron coincidence counting of plutonium metal, oxide, mixed oxide, and scrap and waste. The target values are based in part on past user experience and in part on the estimated results from new coincidence counting techniques that are under development. The paper summarizes assay error sources and the new coincidence techniques, and recommends the technique that is likely to yield the lowest assay uncertainty for a given material type. These target assay uncertainties are intended to be useful for NDA instrument selection and assay variance propagation studies for both new and existing facilities. 14 refs., 3 tabs

  9. Digital gamma-gamma coincidence HPGe system for environmental analysis.

    Science.gov (United States)

    Marković, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-08-01

    The performance of a new gamma-gamma coincidence spectrometer system for environmental samples analysis at the Center for Nuclear Technologies of the Technical University of Denmark (DTU) is reported. Nutech Coincidence Low Energy Germanium Sandwich (NUCLeGeS) system consists of two HPGe detectors in a surface laboratory with a digital acquisition system used to collect the data in time-stamped list mode with 10ns time resolution. The spectrometer is used in both anticoincidence and coincidence modes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Low-resource synchronous coincidence processor for positron emission tomography

    International Nuclear Information System (INIS)

    Sportelli, Giancarlo; Belcari, Nicola; Guerra, Pedro; Santos, Andres

    2011-01-01

    We developed a new FPGA-based method for coincidence detection in positron emission tomography. The method requires low device resources and no specific peripherals in order to resolve coincident digital pulses within a time window of a few nanoseconds. This method has been validated with a low-end Xilinx Spartan-3E and provided coincidence resolutions lower than 6 ns. This resolution depends directly on the signal propagation properties of the target device and the maximum available clock frequency, therefore it is expected to improve considerably on higher-end FPGAs.

  11. Correlated electron-ion collisions in a strong laser field; Korrelierte Elektron-Ion-Stoesse in starken Laserfeldern

    Energy Technology Data Exchange (ETDEWEB)

    Ristow, T.

    2007-12-17

    Electron-ion-collisions in plasmas in the presence of an ultra-short intensive laser pulse can cause high energy transfers to the electrons. During the collision the oscillation energy of the electron in the laser field is changed into drift energy. In this regime, multi-photon processes, known from the ionization of neutral atoms (Above-Threshold Ionization), and successive, so called correlated collisions, are important. The subject of the thesis is a study of binary Coulomb collisions in strong laser fields. The collisions are treated both in the context of classical Newtonian mechanics and in the quantum-mechanical framework by the Schroedinger equation. In the classical case a simplified instantaneous collision model and a complete dynamical treatment are discussed. Collisions can be treated instantaneously, if the ratio of the impact parameter to the quiver amplitude is small. The energy distributions calculated in this approximation show an elastic peak and a broad plateau due to rescattered electrons. At incident velocities smaller than the quiver velocity, correlated collisions are observed in the electron trajectories of the dynamical model. This effect leads to characteristic momentum distributions of the electrons, that are explicitly calculated and compared with the results of the instantaneous model. In addition, the time-dependence of the collisions is discussed in the framework of a singular perturbation theory. The complete description of the Coulomb scattering requires a quantum-mechanical description. A time-dependent method of wave-packet scattering is used and the corresponding time-dependent three-dimensional Schroedinger equation is solved by an implicit ADImethod on a spatial grid. The momentum and the energy distributions of the scattered electrons are calculated by the Fourier transformation of the wavefunction. A comparison of the scattering from a repulsive and an attractive potential is used to distinguish between simple collisions and

  12. Photoelectron photoion coincidence imaging of ultrafast control in multichannel molecular dynamics.

    Science.gov (United States)

    Lehmann, C Stefan; Ram, N Bhargava; Irimia, Daniel; Janssen, Maurice H M

    2011-01-01

    The control of multichannel ionic fragmentation dynamics in CF3I is studied by femtosecond pulse shaping and velocity map photoelectron photoion coincidence imaging. When CF3I is photoexcited with femtosecond laser pulses around 540 nm there are two major ions observed in the time-of-flight mass spectrum, the parent CF3I+ ion and the CF3+ fragment ion. In this first study we focussed on the influence of LCD-shaped laser pulses on the molecular dynamics. The three-dimensional recoil distribution of electrons and ions were imaged in coincidence using a single time-of-flight delay line detector. By fast switching of the voltages on the various velocity map ion lenses after detection of the electron, both the electron and the coincident ion are measured with the same imaging detector. These results demonstrate that a significant simplification of a photoelectron-photoion coincidence imaging apparatus is in principle possible using switched lens voltages. It is observed that shaped laser fields like chirped pulses, double pulses, and multiple pulses can enhance the CF3+CF3I+ ratio by up to 100%. The total energetics of the dynamics is revealed by analysis of the coincident photoelectron spectra and the kinetic energy of the CF3+ and I fragments. Both the parent CF3I+ and the CF3+ fragment result from a five-photon excitation process. The fragments are formed with very low kinetic energy. The photoelectron spectra and CF3+/CF3I+ ratio vary with the center wavelength of the shaped laser pulses. An optimal enhancement of the CF3+/CF3I+ ratio by about 60% is observed for the double pulse excitation when the pulses are spaced 60 fs apart. We propose that the control mechanism is determined by dynamics on neutral excited states and we discuss the results in relation to the location of electronically excited (Rydberg) states of CF3I.

  13. Unattended mode monitoring of passive neutron coincidence detector systems using a commercial data logger

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Outram, J.D.; Storey, M.

    1991-01-01

    A commercial Data Logger for unattended passive neutron coincidence data acquisition is described. This consists of an inexpensive commercial Data Logging equipment attached to a neutron coincidence electronics and a software package for data review. The Data Logger permits both the flexible configuration of a passive neutron coincidence measurement system for unattended mode monitoring and the storage of the measured Totals and Reals count rates. An additional feature of the Data Logger is a custom software package providing for the complete analysis of the stored data and yielding an assay of each item passing through the measurement cavity. The analysis includes an input for different isotopic compositions, the calculation of the multiplication corrected Reals rates, the inclusion of a calibration functions, and the determination of 240 Pu masses. The software package for data review displays the Totals and Reals count rates logged by the Data Logger as a function of time. In addition the custom software provides input files to the data review package to display the multiplication corrected Reals count rates and the measured 240 Pu masses as a function of time. Information on the Data Logger is presented along with the monitoring mode specifications. The analysis functions implemented are described as is the data review software. Results are presented for a specific application

  14. A deadtime reduction circuit for thermal neutron coincidence counters with Amptek preamplifiers

    International Nuclear Information System (INIS)

    Bourret, S.C.; Krick, M.S.

    1994-01-01

    We have developed a deadtime reduction circuit for thermal neutron coincidence counters using Amptek preamplifier/amplifier/discriminator circuits. The principle is to remove the overlap between the output pulses from the Amptek circuits by adding a derandomizer between the Amptek circuits and the shift-register coincidence electronics. We implemented the derandomizer as an Actel programmable logic array; the derandomizer board is small and can be mounted in the high-voltage junction box with the Amptek circuits, if desired. Up to 32 Amptek circuits can be used with one derandomizer. The derandomizer has seven outputs: four groups of eight inputs, two groups of 16 inputs, and one group of 32 inputs. We selected these groupings to facilitate detector ring-ratio measurements. The circuit was tested with the five-ring research multiplicity counter, which has five output signals-one for each ring. The counter's deadtime was reduced from 70 to 30 ns

  15. LINEAR BUNDLES WITHIN THE FRAMEWORK OF COINCIDENCE OF CIRCLE AND ELLIPSE

    Directory of Open Access Journals (Sweden)

    Polezhaev Yuriy Olegovich

    2012-10-01

    Full Text Available Compositions represented by geometrical graphic models of circular and elliptical shapes enjoy wide application in architectural and interior design. The research of variations of coincidences of circles and ellipses is a relevant subject of exploration. In the paper, the authors analyze some of the multiplicity of coincidences, and an example of their practical implementation (a church dome model. The section of an object is "amalgamated" into the architectural concept of the structure, the relief and theological ideas. Geometric interlinks, compositions and figurations of interconnected diameters, circular and elliptical arcs, their tangency, incidences and interspaces have always been of interest to researchers; they have triggered the search for harmonious and rational solutions in civil engineering and architecture. Advancements in theoretical geometrography and its software applications facilitate new solutions.

  16. Ion-ion coincidence imaging at high event rate using an in-vacuum pixel detector

    Science.gov (United States)

    Long, Jingming; Furch, Federico J.; Durá, Judith; Tremsin, Anton S.; Vallerga, John; Schulz, Claus Peter; Rouzée, Arnaud; Vrakking, Marc J. J.

    2017-07-01

    A new ion-ion coincidence imaging spectrometer based on a pixelated complementary metal-oxide-semiconductor detector has been developed for the investigation of molecular ionization and fragmentation processes in strong laser fields. Used as a part of a velocity map imaging spectrometer, the detection system is comprised of a set of microchannel plates and a Timepix detector. A fast time-to-digital converter (TDC) is used to enhance the ion time-of-flight resolution by correlating timestamps registered separately by the Timepix detector and the TDC. In addition, sub-pixel spatial resolution (principle experiment on strong field dissociative double ionization of carbon dioxide molecules (CO2), using a 400 kHz repetition rate laser system. The experimental results demonstrate that the spectrometer can detect multiple ions in coincidence, making it a valuable tool for studying the fragmentation dynamics of molecules in strong laser fields.

  17. CDL, a Precise, Low-Cost Coincidence Detector Latch

    Directory of Open Access Journals (Sweden)

    Ralf Joost

    2015-12-01

    Full Text Available The electronic detection of the coincidence of two events is still a key ingredient for high-performance applications, such as Positron Emission Tomography and Quantum Optics. Such applications are demanding, since the precision of their calculations and thus their conclusions directly depend on the duration of the interval in which two events are considered coincidental. This paper proposes a new circuitry, called coincidence detector latch (CDL, which is derived from standard RS latches. The CDL has the following advantages: low complexity, fully synthesizable, and high scalability. Even in its simple implementation, it achieves a coincidence window width as short as 115 ps, which is more than 10 times better than that reported by recent research.

  18. Importance of interpolation and coincidence errors in data fusion

    Science.gov (United States)

    Ceccherini, Simone; Carli, Bruno; Tirelli, Cecilia; Zoppetti, Nicola; Del Bianco, Samuele; Cortesi, Ugo; Kujanpää, Jukka; Dragani, Rossana

    2018-02-01

    The complete data fusion (CDF) method is applied to ozone profiles obtained from simulated measurements in the ultraviolet and in the thermal infrared in the framework of the Sentinel 4 mission of the Copernicus programme. We observe that the quality of the fused products is degraded when the fusing profiles are either retrieved on different vertical grids or referred to different true profiles. To address this shortcoming, a generalization of the complete data fusion method, which takes into account interpolation and coincidence errors, is presented. This upgrade overcomes the encountered problems and provides products of good quality when the fusing profiles are both retrieved on different vertical grids and referred to different true profiles. The impact of the interpolation and coincidence errors on number of degrees of freedom and errors of the fused profile is also analysed. The approach developed here to account for the interpolation and coincidence errors can also be followed to include other error components, such as forward model errors.

  19. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  20. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  1. Automatic classification of gammas-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.; Gonzalez, J. A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a MULTI-8 minicomputer, is transferred to a new tape in 36 bit words, using the program LEC0M8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program CLAFI. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the UNIVAC 1106 computer of J.E.N. (Author) 4 refs

  2. Optical Co-Incidence Gate | Srinivasulu | African Journal of Science ...

    African Journals Online (AJOL)

    The paper explains Optical co-incidence gate, realized using Unijunction transistors (UJT), Light emitting diodes (LED) and Photo-resistors (LDR), which works on 1.8Vdc instead of 3Vdc. The power dissipation of the designed gate is only 3 mW. This optical gate finds application in the field of Mechatronics, Instrumentation ...

  3. Analysis of (HI, xnγ) coincidence spectra

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Chintalapudi, S.N.

    2000-01-01

    The increase in the sensitivity and the detection limits of the modern third generation gamma detector arrays, has made it necessary to properly understand and estimate the observed background in such experiments. The present paper extends the two algorithms to improve the genuine photo-peak-photo-peak coincident events of interest

  4. Coincidence and common fixed point theorems in compact Hausdorff spaces

    Directory of Open Access Journals (Sweden)

    Zeqing Liu

    2005-01-01

    Full Text Available The existence of coincidence and fixed points for continuous mappings in compact Hausdorff spaces is established. Some equivalent conditions of the existence of fixed and common fixed points for any continuous mapping and a pair of mappings in compact Hausdorff spaces are given, respectively. Our results extend, improve, and unify the corresponding results due to Jungck, Liu, and Singh and Rao.

  5. Non-minimal quintessence: Dynamics and coincidence problem

    Indian Academy of Sciences (India)

    Brans–Dicke scalar–tensor theory provides a conformal coupling of the scalar field with gravity in Einstein's frame. This model is equivalent to an interacting quintessence in which dark matter is coupled to dark energy. This provides a natural mechanism to alleviate the coincidence problem. We investigate the dynamics of ...

  6. Application of coincidence techniques to fusion product measurements

    International Nuclear Information System (INIS)

    Murphy, T.J.; Heidbrink, W.W.; Strachan, J.D.

    1986-06-01

    Measurement of two products of a fusion reaction in coincidence is proposed. Possible detector arrays and sample count rates have been evaluated for reactions in the TFR and TEXT tokamaks and in the TFTR neutral beamlines. The count rates indicate that this method is feasible on existing devices

  7. Non-minimal quintessence: Dynamics and coincidence problem

    Indian Academy of Sciences (India)

    Abstract. Brans–Dicke scalar–tensor theory provides a conformal coupling of the scalar field with gravity in Einstein's frame. This model is equivalent to an interacting quintessence in which dark matter is coupled to dark energy. This provides a natural mechanism to alleviate the coincidence problem. We investigate the ...

  8. Chemical application of positron annihilation through triple coincidence measurement

    International Nuclear Information System (INIS)

    Yegnasubramanian, S.; Gangadharan, S.

    1982-01-01

    This report summarises the work on the application of triple coincidence measurement of annihilation radiation for providing chemical state information; the observations have been corroborated by angular correlation and Doppler broadening measurements and supplemented by the magnetic quenching in the angular correlation and peak-to-valley ratio in the Ge(Li) singles spectrum for the 511 keV line. (author)

  9. Proposed mechanisms for coincidence detection in the auditory brainstem

    Czech Academy of Sciences Publication Activity Database

    Maršálek, Petr; Lánský, Petr

    2005-01-01

    Roč. 92, č. 6 (2005), s. 445-451 ISSN 0340-1200 R&D Projects: GA AV ČR 1ET400110401 Institutional research plan: CEZ:AV0Z50110509 Keywords : neuronal modeling * coincidence detection * hearing Subject RIV: ED - Physiology Impact factor: 1.398, year: 2005

  10. A {beta} - {gamma} coincidence; Metodo de coincidencias {beta} - {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, F.

    1960-07-01

    A {beta} - {gamma} coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from {sup 1}98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs.

  11. Application of neutron multiplicity counting to waste assay

    International Nuclear Information System (INIS)

    Pickrell, M.M.; Ensslin, N.

    1997-01-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A tunable multiplicity approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions

  12. 'TrueCoinc' software utility for calculation of the true coincidence correction

    International Nuclear Information System (INIS)

    Sudar, S.

    2002-01-01

    The true coincidence correction plays an important role in the overall accuracy of the γ ray spectrometry especially in the case of present-day high volume detectors. The calculation of true coincidence corrections needs detailed nuclear structure information. Recently these data are available in computerized form from the Nuclear Data Centers through the Internet or on a CD-ROM of the Table of Isotopes. The aim has been to develop software for this calculation, using available databases for the levels data. The user has to supply only the parameters of the detector to be used. The new computer program runs under the Windows 95/98 operating system. In the framework of the project a new formula was prepared for calculating the summing out correction and calculation of the intensity of alias lines (sum peaks). The file converter for reading the ENDSF-2 type files was completed. Reading and converting the original ENDSF was added to the program. A computer accessible database of the X rays energies and intensities was created. The X ray emissions were taken in account in the 'summing out' calculation. Calculation of the true coincidence 'summing in' correction was done. The output was arranged to show independently two types of corrections and to calculate the final correction as multiplication of the two. A minimal intensity threshold can be set to show the final list only for the strongest lines. The calculation takes into account all the transitions, independently of the threshold. The program calculates the intensity of X rays (K, L lines). The true coincidence corrections for X rays were calculated. The intensities of the alias γ lines were calculated. (author)

  13. A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors

    International Nuclear Information System (INIS)

    Gamage, Kelum A.A.; Joyce, Malcolm J.; Cave, Frank D.

    2013-06-01

    Neutron coincidence counting is an established, nondestructive method for the qualitative and quantitative analysis of nuclear materials. Several even-numbered nuclei of the actinide isotopes, and especially even-numbered plutonium isotopes, undergo spontaneous fission, resulting in the emission of neutrons which are correlated in time. The characteristics of this i.e. the multiplicity can be used to identify each isotope in question. Similarly, the corresponding characteristics of isotopes that are susceptible to stimulated fission are somewhat isotope-related, and also dependent on the energy of the incident neutron that stimulates the fission event, and this can hence be used to identify and quantify isotopes also. Most of the neutron coincidence counters currently used are based on 3 He gas tubes. In the 3 He-filled gas proportional-counter, the (n, p) reaction is largely responsible for the detection of slow neutrons and hence neutrons have to be slowed down to thermal energies. As a result, moderator and shielding materials are essential components of many systems designed to assess quantities of fissile materials. The use of a moderator, however, extends the die-away time of the detector necessitating a larger coincidence window and, further, 3 He is now in short supply and expensive. In this paper, a simulation based on the Monte Carlo method is described which has been performed using MCNPX 2.6.0, to model the geometry of a sector-shaped liquid scintillation detector in response to coincident neutron events. The detection of neutrons from a mixed-oxide (MOX) fuel pellet using an organic liquid scintillator has been simulated for different thicknesses of scintillators. In this new neutron detector, a layer of lead has been used to reduce the gamma-ray fluence reaching the scintillator. The effect of lead for neutron detection has also been estimated by considering different thicknesses of lead layers. (authors)

  14. Using CHIMERA detector at LNS for gamma-particle coincidences

    Directory of Open Access Journals (Sweden)

    Cardella G.

    2016-01-01

    Full Text Available We have recently evaluated the quality of γ-ray angular distributions that can be extracted in particle-gamma coincidence measurements using the CHIMERA detector at LNS. γ-rays have been detected using the CsI(Tl detectors of the spherical part of the CHIMERA array. Very clean γ-rays angular distributions were extracted in reactions induced by different stable beams impinging on 12C thin targets. The results evidenced an effect of projectile spin flip on the γ-rays angular distributions. γ-particle coincidence measurements were also performed in reactions induced by neutron rich exotic beams produced through in-flight fragmentation at LNS. In recent experiments also the Farcos array was used to improve energy and angular resolution measurements of the detected charged particles. Results obtained with both stable and radioactive beams are reported.

  15. Simplified slow anti-coincidence circuit for Compton suppression systems

    Energy Technology Data Exchange (ETDEWEB)

    Al-Azmi, Darwish [Department of Applied Sciences, College of Technological Studies, Public Authority for Applied Education and Training, P.O. Box 42325, Shuwaikh 70654 (Kuwait)], E-mail: ds.alazmi@paaet.edu.kw

    2008-08-15

    Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The system has been tested to observe the improvement in the energy spectra for medium to high-energy gamma-ray photons from terrestrial and environmental samples.

  16. Device for multi-dimensional γ-γ-coincidence study

    International Nuclear Information System (INIS)

    Gruzinova, T.M.; Erokhina, K.I.; Kutuzov, V.I.; Lemberg, I.Kh.; Petrov, S.A.; Revenko, V.S.; Senin, A.T.; Chugunov, I.N.; Shishlinov, V.M.

    1977-01-01

    A device for studying multi-dimensional γ-γ coincidences is described which operates on-line with the BESM-4 computer. The device comprises Ge(Li) detectors, analog-to-digital converters, shaper discriminators and fast amplifiers. To control the device operation as a whole and to elaborate necessary commands, an information distributor has been developed. The following specific features of the device operation are noted: the device may operate both in the regime of recording spectra of direct γ radiation in the block memory of multi-channel analyzer, and in the regime of data transfer to the computer memory; the device performs registration of coincidences; it transfers information to the computer which has a channel of direct access to the memory. The procedure of data processing is considered, the data being recorded on a magnetic tape. Partial spectra obtained are in a good agreement with data obtained elsewhere

  17. What can we learn about fragmentation from coincidence experiments?

    International Nuclear Information System (INIS)

    Kaufman, S.B.

    1987-01-01

    It has become clear that in order to characterize a complex process such as nuclear fragmentation more exclusive experimental measurements must be performed, i.e., the correlations between coincident fragments must be determined. Some types of correlations are readily interpreted in terms of specific mechanisms, for example, the angular correlation between two heavy fragments. Binary (fission-like) breakup results in relatively strong angular correlations, while no strong correlations are expected for a multi-body fragmentation mechanism. Data from coincidence measurements of the fragmentation of uranium and gold targets by relativistic projectiles are presented which illustrate these points. The interplay between such experiments and model calculations of fragmentation is discussed. 19 refs., 9 figs

  18. Simplified slow anti-coincidence circuit for Compton suppression systems

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2008-01-01

    Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The system has been tested to observe the improvement in the energy spectra for medium to high-energy gamma-ray photons from terrestrial and environmental samples

  19. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  20. The coincidence of dementia and intracranial tumours. Avoidable misdiagnosis

    International Nuclear Information System (INIS)

    Schroeder, M.; Maerz, U.

    1997-01-01

    The case of a 66-year-old female suffering from a large olfactory groove meningioma with first diagnosis of 'Alzheimer's disease' exemplifies problems that occur in the differential diagnosis of dementia. Special regard is given to the coincidence of dementia and intracranial tumours. The case described above shows that early neuroimaging is advisable to exclude idiopathic from remediable dementias in order to offer the possibility of intervention. (orig.) [de

  1. A coincidence of addiction to "Kratom" and severe primary hypothyroidism.

    Science.gov (United States)

    Sheleg, Sergey V; Collins, Gregory B

    2011-12-01

    Here we present a case of a coincidence of addiction to "Kratom" (botanically known as Mitragyna speciosa Korth) and developed severe primary hypothyroidism. We are discussing a possibility that high dose of indole alkaloid mitragynine (the major alkaloid identified from "Kratom") might reduce the normal response of the thyroid gland to thyroid-stimulating hormone resulting in primary hypothyroidism. Further experimental investigations of mitragynine as a possible suppressor of thyroid gland function would be a matter of interest.

  2. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  3. Post training REMs coincident auditory stimulation enhances memory in humans.

    Science.gov (United States)

    Smith, C; Weeden, K

    1990-06-01

    Sleep activity was monitored in 20 freshman college students for two consecutive nights. Subjects were assigned to 4 equal groups and all were asked to learn a complex logic task before bed on the second night. Two groups of subjects learned the task with a constant clicking noise in the background (cued groups), while two groups simply learned the task (non cued). During the night, one cued and one non cued group were presented with auditory clicks during REM sleep such as to coincide with all REMs of at least 100 microvolts. The second cued group was given auditory clicks during REM sleep, but only during the REMs "quiet" times. The second non-cued control group was never given any nighttime auditory stimulations. The cued REMs coincident group showed a significant 23% improvement in task performance when tested one week later. The non cued REMs coincident group showed only an 8.8% improvement which was not significant. The cued REMs quiet and non-stimulated control groups showed no change in task performance when retested. The results were interpreted as support for the idea that the cued auditory stimulation induced a "recall" of the learned material during the REM sleep state in order for further memory processing to take place.

  4. Importance of interpolation and coincidence errors in data fusion

    Directory of Open Access Journals (Sweden)

    S. Ceccherini

    2018-02-01

    Full Text Available The complete data fusion (CDF method is applied to ozone profiles obtained from simulated measurements in the ultraviolet and in the thermal infrared in the framework of the Sentinel 4 mission of the Copernicus programme. We observe that the quality of the fused products is degraded when the fusing profiles are either retrieved on different vertical grids or referred to different true profiles. To address this shortcoming, a generalization of the complete data fusion method, which takes into account interpolation and coincidence errors, is presented. This upgrade overcomes the encountered problems and provides products of good quality when the fusing profiles are both retrieved on different vertical grids and referred to different true profiles. The impact of the interpolation and coincidence errors on number of degrees of freedom and errors of the fused profile is also analysed. The approach developed here to account for the interpolation and coincidence errors can also be followed to include other error components, such as forward model errors.

  5. High sensitivity neutron activation analysis using coincidence counting method

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    1999-01-01

    Four kinds of standard samples such as river sediment (NIES CRM No.16), Typical Japanese Diet, otoliths and river water were irradiated by TRIGA-II (100 kW, 3.7x10 12 n cm -2 s -1 ) for 6 h. After irradiation and cooling, they were analyzed by the coincidence counting method and a conventional γ-ray spectrometry. Se, Ba and Hf were determined by 75 Se 265 keV, 131 Ba 496 keV and 181 Hf 482 keV. On the river sediment sample, Ba and Hf showed the same values by two methods, but Se value contained Ta by the conventional method, although the coincidence counting method could analyze Se. On Typical Japanese Diet and otoliths, Se could be determined by two methods and Ba and Hf determined by the coincidence counting method but not determined by the conventional method. Se value in the river water agreed with the authorization value. (S.Y.)

  6. Recent Advances in Digital Coincidence Counting for Radionuclide Metrology

    International Nuclear Information System (INIS)

    Keightley, John; Bobin, Christophe; Bouchard, Jacques; Capogni, Marco; Loreti, Stefano; Roteta, Miguel

    2013-06-01

    The radioactivity measurement techniques developed within the EURAMET EMRP 'MetroFission' Joint Research Project, were aimed at performing on-site activity measurements at the primary standard level (4πβ-γ coincidence counting) for a wide range of radionuclides utilizing recent advances in high-speed digital sampling and digital signal processing. The state-of-the-art technology employed within this project provides up to 14-bit digitizer systems operating with sampling rates in the order of 10 8 to 10 9 samples-per-second, incorporating on-board FPGA devices, which greatly enhances the application of digital signal processing for the implementation of digital coincidence counting. These devices when coupled to suitable analysis software, demonstrate a significant improvement in the provision of primary standards of radioactivity. This manuscript provides a description of the systems employed, along with recommendations regarding optimization of the digital sampling of signals from photo-multiplier tubes and pre-amplifiers and compare the benefits of 'off-line' versus 'on-line' 4πβ-γ digital coincidence counting systems. (authors)

  7. X-ray line coincidence photopumping in a solar flare

    Science.gov (United States)

    Keenan, F. P.; Poppenhaeger, K.; Mathioudakis, M.; Rose, S. J.; Flowerdew, J.; Hynes, D.; Christian, D. J.; Nilsen, J.; Johnson, W. R.

    2018-03-01

    Line coincidence photopumping is a process where the electrons of an atomic or molecular species are radiatively excited through the absorption of line emission from another species at a coincident wavelength. There are many instances of line coincidence photopumping in astrophysical sources at optical and ultraviolet wavelengths, with the most famous example being Bowen fluorescence (pumping of O III 303.80 Å by He II), but none to our knowledge in X-rays. However, here we report on a scheme where a He-like line of Ne IX at 11.000 Å is photopumped by He-like Na X at 11.003 Å, which predicts significant intensity enhancement in the Ne IX 82.76 Å transition under physical conditions found in solar flare plasmas. A comparison of our theoretical models with published X-ray observations of a solar flare obtained during a rocket flight provides evidence for line enhancement, with the measured degree of enhancement being consistent with that expected from theory, a truly surprising result. Observations of this enhancement during flares on stars other than the Sun would provide a powerful new diagnostic tool for determining the sizes of flare loops in these distant, spatially unresolved, astronomical sources.

  8. Multi-channel Andreev reflection in Co-W nanocontacts fabricated using focused electron/ion beam induced deposition.

    Science.gov (United States)

    Sharma, N; Vugts, P; Daniels, C; Keuning, W; Kohlhepp, J T; Kurnosikov, O; Koopmans, B

    2014-12-12

    We report multi-channel electron transport in nano-contacts fabricated using focused electron beam induced deposited (FEBID) cobalt and focused ion beam induced deposited (FIBID) tungsten. Anomalous Andreev reflection (AR) effect is observed to which the conventional Blonder-Tinkham-Klapwijk (BTK) fit cannot be applied. In specific, we have observed multiple number of shoulders near the AR peak, whose origin is unknown in literature. We explain this effect based on a simple model that takes into account the material properties of the FIBID grown W superconductor, as well as the specific interface properties that are an outcome of using FEBID/FIBID as a fabrication technique. We show that numerical calculations using the BTK approximation based on the consideration of multiple channels generate similar shoulders as we observed in the AR experiments. Electrical measurements and x-ray photoemission spectroscopy carried out on FIBID W deposits puts additional evidence towards multi-channel current transport occuring at the interface of the nanocontacts.

  9. Coincident-site lattice matching during van der Waals epitaxy

    OpenAIRE

    Boschker, Jos E.; Galves, Lauren A.; Flissikowski, Timur; Lopes, Joao Marcelo J.; Riechert, Henning; Calarco, Raffaella

    2015-01-01

    Van der Waals (vdW) epitaxy is an attractive method for the fabrication of vdW heterostructures. Here Sb2Te3 films grown on three different kind of graphene substrates (monolayer epitaxial graphene, quasi freestanding bilayer graphene and the SiC (6?3???6?3)R30? buffer layer) are used to study the vdW epitaxy between two 2-dimensionally (2D) bonded materials. It is shown that the Sb2Te3 /graphene interface is stable and that coincidence lattices are formed between the epilayers and substrate ...

  10. Correlated multiphoton holes: absence of multiphoton coincidence events.

    Science.gov (United States)

    Afek, I; Ambar, O; Silberberg, Y

    2010-08-27

    We generate bipartite states of light which exhibit an absence of multiphoton coincidence events between two modes amid a constant background flux. These "correlated photon holes" are produced by mixing a coherent state and relatively weak spontaneous parametric down-conversion by using a balanced beam splitter. Correlated holes with arbitrarily high photon numbers may be obtained by adjusting the relative phase and amplitude of the inputs. We measure states of up to five photons and verify their nonclassicality. The scheme provides a route for observation of high-photon-number nonclassical correlations without requiring intense quantum resources.

  11. Coincident systemic lupus erythematosus and psoriasis vulgaris: a case report.

    Science.gov (United States)

    Wang, Y; Da, G; Yu, Y; Han, J; Li, H

    2015-12-01

    Psoriasis vulgaris is an autoimmune chronic inflammatory skin disease, but its association with other typical autoimmune disease such as systemic lupus erythematosus has only occasionally been reported. We presented a 25-year-old female who developed systemic lupus erythematosus associated with psoriasis vulgaris. Her conditions were in good control after she got administration of prednisolone (5 mg/day) and Tripterygium Wilfordii Hook (20 mg/day). It is necessary to integrate past history and physical examination to diagnose coincident SLE and psoriasis, and combined treatment with prednisolone and Tripterygium Wilfordii Hook proves effective.

  12. Some remarks on dead-time losses of coincidences

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1976-01-01

    Dead-time effects for coincident pulses are known to be a very difficult subject. Apart from some trivial cases, no rigorous results are yet known. For all practical applications, approximate solutions are used, the quality of which is difficult to judge. Whereas in general they seem to be sufficiently reliable, their deficiency begins to show up clearly for very high count rates. Unfortunately, the present small note will not really improve this situation. It may, however, provide some guideline for the credibility of the various approaches which have been suggested

  13. High-level neutron coincidence counter maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  14. High-level neutron coincidence counter maintenance manual

    International Nuclear Information System (INIS)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included

  15. Coincidence corrected efficiency calibration of Compton-suppressed HPGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Aucott, Timothy [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brand, Alexander [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); DiPrete, David [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-20

    The authors present a reliable method to calibrate the full-energy efficiency and the coincidence correction factors using a commonly-available mixed source gamma standard. This is accomplished by measuring the peak areas from both summing and non-summing decay schemes and simultaneously fitting both the full-energy efficiency, as well as the total efficiency, as functions of energy. By using known decay schemes, these functions can then be used to provide correction factors for other nuclides not included in the calibration standard.

  16. Stroboscopic vision and sustained attention during coincidence-anticipation.

    Science.gov (United States)

    Ballester, Rafael; Huertas, Florentino; Uji, Makoto; Bennett, Simon J

    2017-12-20

    We compared coincidence-anticipation performance in normal vision and stroboscopic vision as a function of time-on-task. Participants estimated the arrival time of a real object that moved with constant acceleration (-0.7, 0, +0.7 m/s 2 ) in a pseudo-randomised order across 4 blocks of 30 trials in both vision conditions, received in a counter-balanced order. Participants (n = 20) became more errorful (accuracy and variability) in the normal vision condition as a function of time-on-task, whereas performance was maintained in the stroboscopic vision condition. We interpret these data as showing that participants failed to maintain coincidence-anticipation performance in the normal vision condition due to monotony and attentional underload. In contrast, the stroboscopic vision condition placed a greater demand on visual-spatial memory for motion extrapolation, and thus participants did not experience the typical vigilance decrement in performance. While short-term adaptation effects from practicing in stroboscopic vision are promising, future work needs to consider for how long participants can maintain effortful processing, and whether there are negative carry-over effects from cognitive fatigue when transferring to normal vision.

  17. Coincidence of lung cancer and silicosis in Czechoslovak uranium miners

    International Nuclear Information System (INIS)

    Urban, S.; Urbanova, S.

    1988-01-01

    27 patients with established coincidence of lung cancer and silicosis from a group of 1607 cases of lung cancer from radioactive compounds, and 166 cases of pneumoconiosis were reported by the Occupational Diseases Ward of the works Institute of National Health in Uranium Industry in the 1962 to 1986 years. Lung cancer was found in 16% of reported silicosis patients, in 81% it was simple silicosis, in 50% of cases in was an epidermoid type of cancer. In two cases the malignant process originated in the silicotic node, in one case from a tuberculoma. Lung cancer occurred most frequently in the right lower lung region. The mean age of the silicosis group was 48.6 years and 56.0 years for the lung cancer group. No difference was thus seen from the mean age of patients with lung cancer from radioactive compounds diagnosed in the years 1976 to 1980 but it was significantly lower that the reported average age of patients with coincidence of lung cancer and pneumoconiosis in the population not exposed to ionizing radiation. (author). 2 figs., 1 tab., 18 refs

  18. Performance of a coincidence based blood activity monitor

    International Nuclear Information System (INIS)

    Moses, W.W.

    1989-12-01

    A new device has been constructed that measures the positron emitting radio-tracer concentration in arterial blood by extracting blood with a peristaltic pump, then measuring the activity concentration by detecting coincident pairs of 511 keV photons with a pair of heavy inorganic scintillators attached to photomultiplier tubes. The sensitivity of this device is experimentally determined to be 610 counts/second per μCi/ml, and has a paralyzing dead time of 1.2 μs, so is capable of measuring blood activity concentration as high as 1 mCi/ml. Its performance is compared to two other blood monitoring methods: discrete blood samples counted with a well counter and device that uses a plastic scintillator to directly detect positrons. The positron detection efficiency of this device for 18 F is greater than the plastic scintillation counter, and also eliminates the radioisotope dependent correction factors necessary to convert count rate to absolute concentration. Coincident photon detection also has the potential of reducing the background compared to direct positron detection, thereby increasing the minimum detectable isotope concentration. 10 refs., 6 figs

  19. Is there another coincidence problem at the reionization epoch?

    Science.gov (United States)

    Lombriser, Lucas; Smer-Barreto, Vanessa

    2017-12-01

    The cosmological coincidences between the matter and radiation energy densities at recombination as well as between the densities of matter and the cosmological constant at the present time are well known. We point out that, moreover, the third intersection between the energy densities of radiation and the cosmological constant coincides with the reionization epoch. To quantify the statistical relevance of this concurrence, we compute the Bayes factor between the concordance cosmology with free Thomson scattering optical depth and a model for which this parameter is inferred from imposing a match between the time of density equality and the epoch of reionization. This is to characterize the potential explanatory gain if one were to find a parameter-free physical connection. We find a very strong preference for such a concurrence on the Jeffreys scale from current cosmological observations. We furthermore discuss the effect of the choice of priors, changes in reionization history, and free sum of neutrino masses. We also estimate the impact of adding intermediate polarization data from the Planck High Frequency Instrument and prospects for future 21 cm surveys. In the first case, the preference for the correlation remains substantial, whereas future data may give results more decisive in pro or substantial in contra of it. Finally, we provide a discussion on different interpretations of these findings. In particular, we show how a connection between the star-formation history and the cosmological background dynamics can give rise to this concurrence.

  20. An application of the refined born approximation to the solution of coupled equations involved in electron-ion and electron-atom scattering problems

    Science.gov (United States)

    Staszewska, G.

    1981-06-01

    A new approach to the solution of coupled equations involved in electron-ion and electron-atom scattering problems is proposed. This method is a combination of iteration and variation procedures. The main advantage of this method is that exchange terms can be calculated in a direct and straightforward manner. The method is based on the Lippmann-Schwinger equation and does not require trial functions satisfying appropriate boundary conditions. Using the Volterra formulation one can find the solution on an interval determined by the range of the exchange potential and the long-range potential terms can be taken into account by a projection procedure giving the asymptotic value of the reactance matrix. The method is tested on the case of electron-hydrogen atom scattering in the 1s-2s and 1s-2s-2p approximation. We have adapted the method proposed originally by Rayski to obtain solutions of coupled equations involved in electron-ion and electron-atom scattering. As mentioned in section 1 the construction of the method secures an automatic fulfilment of the boundary conditions. It allows an easy calculation of the exchange potential as well as an estimation of the introduced approximation. It gives also a possibility of detecting any spurious convergence. Moreover, it is important that this formalism can be applied in the case of normalized as well as unnormalized initial integral equations. This fact is of special importance in the case of long-range interactions. When the method is used for unnormalized (Volterra) equations it allows application of a very convenient projection procedure for treating the long-range terms in the direct potential. Electron-hydrogen atom collisions are investigated as a numerical illustration of the method. In the 1s-2s approximation the normalized equations were solved, while in the 1s-2s-2p approximation the solution was obtained with the help of Volterra equations and the long-range terms of the direct potential were taken into account

  1. Evaluation of double photon coincidence Compton imaging method with GEANT4 simulation

    Science.gov (United States)

    Yoshihara, Yuri; Shimazoe, Kenji; Mizumachi, Yuki; Takahashi, Hiroyuki

    2017-11-01

    Compton imaging has been used for various applications including astronomical observations, radioactive waste management, and biomedical imaging. The positions of radioisotopes are determined in the intersections of multiple cone traces through a large number of events, which reduces signal to noise ratio (SNR) of the images. We have developed an advanced Compton imaging method to localize radioisotopes with high SNR by using information of the interactions of Compton scattering caused by two gamma rays at the same time, as the double photon coincidence Compton imaging method. The targeted radioisotopes of this imaging method are specific nuclides that emit several gamma rays at the same time such as 60Co, 134Cs, and 111In, etc. Since their locations are determined in the intersections of two Compton cones, the most of cone traces would disappear in the three-dimensional space, which enhances the SNR and angular resolution. In this paper, the comparison of the double photon coincidence Compton imaging method and the single photon Compton imaging method was conducted by using GEANT4 Monte Carlo simulation.

  2. Molybdenum Cluster Chalcogenides: In Situ X-Ray Studies on the Formation of Cu xMo 6S 8 via Electron/Ion Transfer

    Science.gov (United States)

    Fischer, C.; Gocke, E.; Stege, U.; Schöllhorn, R.

    1993-01-01

    Systematic structural investigation have been performed on the formation of the ternary Chevrel phase system CuxMo6S8 by topotactic intercalation of copper into Mo6S8 via electron/ion transfer reactions. In high-temperature synthesis the homogeneity range of CuxMo6S8 formation corresponds to 1.8 ≤ x ≤ 3.66, while by galvanostatic or potentiostatic reduction of binary Mo6S8 at ambiet temperature in aqueous CuSO4 or aprotic CuCl/Ch3CN electrolyte the terminal rhombohedral phase Cu4Mo6S8 with the maximum number of electrons per Mo6 cluster can be obtained. The phase range 1 ≤ x ≤ 4 of CuxMo6S8 as obtained by galvanostatic reduction of Mo6S8 in aqueous CuSO4 electrolyte has been determined by in situ X-ray experiments. Warburg oxygen manometry has proved to be a new and powerful analytical tool for examination of the Cu content of ternary phase CuxMo6S8. Thermodiffractometry and 63 Cu NMR studies of Cu2Mo6S8 (high-temperature phase) reveal a phase-transition rhombohedral/triclinic in a broad temperature range between 285 and 200 K. Superconducting properties (temperature-dependent ac susceptibility) of high temperature and electrochemically prepared Cu phases are reported.

  3. Development of a Bunched Beam Electron Cooler based on ERL and Circulator Ring Technology for the Jefferson Lab Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Benson, Stephen V. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Derbenev, Yaroslav S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Douglas, David R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Hannon, Fay E. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Hutton, Andrew M. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Li, Rui [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Rimmer, Robert A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Roblin, Yves R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Tennant, Christopher D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wang, Haipeng [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, He [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, Yuhong [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2018-01-01

    Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second uses a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.

  4. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  5. The spallation in reverse kinematics: what for a coincidence measurement?

    International Nuclear Information System (INIS)

    Ducret, J.E.

    2006-07-01

    The Spaladin installation has been designed to study spallation reactions in reverse kinematics. Furthermore, the heavy and light fragments are detected by coincidence which allows us to get an instantaneous picture of the reaction at a level of accuracy better than that obtained through inclusive measurement. The first part is dedicated to the theoretical description of the different mechanisms involved in the spallation reactions. In the second part we describe the Spaladin installation and report some results on the reaction: Fe 56 + p at an energy of 1 GeV/nucleon. In the third part we expose the performance of the installation through its simulation with the Geant-IV model. We present a study about the sensitivity of the Spaladin installation to theoretical predictions. The fourth part is dedicated to the future experiments that will be performed with the Spaladin installation. (A.C.)

  6. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  7. Analysis of 125Xe electron-photon coincidence decay

    International Nuclear Information System (INIS)

    Klingberg, F.J.; Biegalski, S.R.

    2016-01-01

    As part of the verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), environmental gas samples originating from nuclear fission are analyzed for the presence of 131m Xe, 133m Xe, 133 Xe, and 135 Xe. In this work, the non-traditional radioxenon isotope 125 Xe was investigated. The isotope was produced as an isotopically pure sample via neutron activation of 124 Xe at the University of Texas at Austin Nuclear Engineering Teaching Lab's TRIGA MARK II Reactor. The sample was then measured using a HPGe detector as well as an ARSA-style b-c coincidence detector. Potential sources and sensitivities for production of 125 Xe are also considered for relevance to the CTBT verification mission. (author)

  8. Analysis of coincidence-time loopholes in experimental Bell tests

    Science.gov (United States)

    Christensen, B. G.; Hill, A.; Kwiat, P. G.; Knill, E.; Nam, S. W.; Coakley, K.; Glancy, S.; Shalm, L. K.; Zhang, Y.

    2015-09-01

    We apply a distance-based Bell-test analysis method [E. Knill et al., Phys. Rev. A 91, 032105 (2015), 10.1103/PhysRevA.91.032105] to three experimental data sets where conventional analyses failed or required additional assumptions. The first is produced from a classical source exploiting a "coincidence-time loophole" for which standard analysis falsely shows a Bell violation. The second is from a source previously shown to violate a Bell inequality; the distance-based analysis agrees with the previous results but with fewer assumptions. The third data set does not show a violation with standard analysis despite the high source quality, but is shown to have a strong violation with the distance-based analysis method.

  9. On the spatial coincidence of hydroxyl and methanol masers

    Science.gov (United States)

    Hartquist, T. W.; Menten, K. M.; Lepp, S.; Dalgarno, A.

    1995-01-01

    We argue that purely gas-phase chemical models for the production of OH in hydroxyl masers around ultracompact H II regions such as W3(OH) cannot account for the CH_3OH in the methanol masers that are found to coincide with the hydroxyl masers in these sources. We suggest that the CH_3OH in the masers is injected into the gas phase by evaporation of the grain mantles, the grains being heated by the passage of weak shocks. Gas evaporation also injects H_2O into the gas. Photodissociation of H_2O, CH_3OH and OH occur at similar rates, and substantial abundances of CH_3OH and OH coexist.

  10. Passive Time Coincidence Measurements with HEU and DU Metal Castings

    International Nuclear Information System (INIS)

    McConchie, Seth M.; Hausladen, Paul; Mihalczo, John T.; Wright, Michael C.; Archer, Daniel E.

    2008-01-01

    A Department of Energy sponsored Oak Ridge National Laboratory/Y-12 National Security Complex program of passive time coincidence measurements has been initiated at Y-12 to evaluate the ability to determine the presence of high enriched uranium (HEU) and distinguish it from depleted uranium (DU). This program uses the Nuclear Materials Identification System (NMIS) without an active interrogation source. Previous passive NMIS measurements with Pu metal and Pu oxide have been successful in determining the Pu mass, assuming a known 240Pu content. The spontaneous fission of uranium metal is considerably lower than Pu and measurements of this type have been performed at Lawrence Livermore National Laboratory. This work presents results of measurements of HEU and DU metal castings using moderated 3He detectors.

  11. Coincident photoelectron spectroscopy on superconductors; Koinzidente Photoelektronenspektroskopie an Supraleitern

    Energy Technology Data Exchange (ETDEWEB)

    Voss, Stefan

    2011-07-01

    Aim of the performed experiments of this thesis was to attempt to detect Cooper pairs as carriers of the superconducting current directly by means of the photoelectric effect. The method of the coincident photoelectron spectroscopy aims thereby at the detection of two coherently emitted electrons by the interaction with a photon. Because electrostatic analyzers typically cover only a very small spatial angle, which goes along with very low coincidence rates, in connection with this thesis a time-of-flight projection system has been developed, which maps nearly the whole spatial angle on a position-resolving detector. The pulsed light source in form of special synchrotron radiation necessary for the measurement has been adjusted so weak, that only single photons could arrive at the sample. Spectroscoped were beside test measurements on silver layers both a lead monocrystal as representative of the classical BCS superconductors and monocrystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} from the family of the high-temperature superconductors. With excitation energies up to 40 eV could be shown that sufficiently smooth and clean surfaces in the superconducting phase exhibit within the resolving power of about 0.5 eV no recognizable differences in comparison to the normally conducting phase. Beside these studies furthermore the simple photoemission at the different samples and especially in the case of the lead crystal is treated, because here no comparable results are known. Thereby the whole momentum space is discussed and the Fermi surface established as three-dimensional model, by means of which the measurement results are discussed. in the theoretical descriptions different models for the Cooper-pair production are presented, whereby to the momentum exchange with the crystal a special role is attributed, because this can only occur in direct excitations via discrete lattice vectors.

  12. VUV state-selected photoionization of thermally-desorbed biomolecules by coupling an aerosol source to an imaging photoelectron/photoion coincidence spectrometer: case of the amino acids tryptophan and phenylalanine.

    Science.gov (United States)

    Gaie-Levrel, François; Garcia, Gustavo A; Schwell, Martin; Nahon, Laurent

    2011-04-21

    Gas phase studies of biological molecules provide structural and dynamical information on isolated systems. The lack of inter- or intra-molecular interactions facilitates the interpretation of the experimental results through theoretical calculations, and constitutes an informative complement to the condensed phase. However advances in the field are partially hindered by the difficulty of vaporising these systems, most of which are thermally unstable. In this work we present a newly developed aerosol mass thermodesorption setup, which has been coupled to a Velocity Map Imaging (VMI) analyzer operated in coincidence with a Wiley-McLaren Time of Flight spectrometer, using synchrotron radiation as a single photon ionization source. Although it has been previously demonstrated that thermolabile molecules such as amino acids can be produced intact by the aerosol vaporisation technique, we show how its non-trivial coupling to a VMI analyzer plus the use of electron/ion coincidences greatly improves the concept in terms of the amount of spectroscopic and dynamic information that can be extracted. In this manner, we report on the valence shell ionization of two amino acids, tryptophan and phenylalanine, for which threshold photoelectron spectra have been recorded within the first 3 eV above the first ionization energy using synchrotron radiation emitted from the DESIRS beamline located at SOLEIL in France. Their adiabatic ionization energies (IEs) have been measured at 7.40 ± 0.05 and 8.65 ± 0.02 eV, respectively, and their spectra analyzed using existing theoretical data from the literature. The IE values agree well with previously published ones, but are given here with a considerably reduced uncertainty by up to a factor of 5. The photostability of both amino acids is also described in detail, through the measurement of the state-selected fragmentation pathways via the use of threshold electron/ion coincidences (TPEPICO), with appearance energies for the different

  13. Calibration of HPGe-HPGe coincidence spectrometer through performing standardisation of 125I activity by X-ray-gamma coincidence spectrometry using two HPGe detectors

    Science.gov (United States)

    Marković, Nikola; Roos, Per; Hou, Xiaolin; Nielsen, Sven Poul

    2018-02-01

    An X-ray-gamma coincidence measurement method for efficiency calibration of a HPGe-HPGe system, using the methodology for activity standardisation of 125I, has been developed. By taking one list-mode time-stamped measurement of the 125I source, six spectra were generated in post-processing: total spectra, coincidence spectra and energy gated coincidence spectra for each of the two detectors. The method provides enough observables for source activity to be determined without a prior knowledge of the detector efficiencies. In addition, once the source is calibrated in this way the same spectra can also be used to perform efficiency calibration of the individual detectors in the low energy range. This new methodology for source activity determination is an alternative to the already established X-ray-(X-ray, gamma) coincidence counting method; with two NaI(Tl) detectors and the sum-peak method using a single HPGe detector. When compared to the coincidence counting method using two NaI(Tl) detectors, the newly developed method displays improved energy resolution of HPGe detectors combined with measurement of only full peak areas, without the need for total efficiency determination. This enables activity determination even in presence of other gamma emitters in the sample. Standard coincidence counting with NaI(Tl) detectors provides lower uncertainties. The method has been used for calibration of a coincidence HPGe spectrometer in the low energy range of 125I and fine adjustments of a Monte Carlo model of the coincidence system.

  14. Coincidence and awareness of oral parafunctions in college students.

    Science.gov (United States)

    Panek, H; Nawrot, P; Mazan, M; Bielicka, B; Sumisławska, M; Pomianowski, R

    2012-03-01

    The aim of the study was to determine the prevalence and awareness of particular types of oral parafunctions in young healthy students and any association with temporomandibular disorders (TMD). The study was performed in a randomly selected group of 303 healthy students (mean age 18.8 years) from the vocational technical school in Wrocław, Poland, who underwent a routine clinical examination and functional analysis of the mouth. On taking the history all subjects were asked about their awareness of various forms of parafunctional activity in their mouth. Almost all subjects revealed various oral parafunctions such as: bruxism, nail and pen biting, chewing gum, and biting the mucosa of lip or cheek. These habits were present singly or as double, triple or even fourfold coincidences in a single person. The most frequent oral parafunctions were habitual gum chewing and bruxism. Subjects were very seldom aware of the last parafunction. TMDs were more prevalent in the presence of bruxism than in other oral parafunctions. The studied students revealed various types of oral parafunctions, however most of them were not aware of clenching and grinding their teeth.

  15. Interaction of multicharged ions with molecules (CO{sub 2}, C{sub 60}) by coincident electron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A. [Universite Paul Sabatier, Toulouse (France). Lab. CAR-IRSAMC

    2001-07-01

    First results for the investigation of electron capture processes in collisions between multicharged ions and molecule targets using electron spectroscopy in coincidence with charged fragments, are presented. It is shown that a much more detailed investigation of the capture reaction can be achieved using molecular instead of heavy atomic targets provided that an analysis of the target dissociation is made. The collisional systems {sup 18}O{sup 8+}+Ar, CO{sub 2} and C{sub 60} have been studied at 80 keV. Non coincident electron spectra as well as first results of double or triple coincidence experiments are discussed. Kinetic energy distributions of the C{sub n}{sup +} fragments (n=1 to 8) produced in multiple capture processes from C{sub 60} target are given. A detailed investigation of the double capture process with CO{sub 2} molecule allows the measurement of kinetic energy release distributions (KERD) which characterize the dissociation of CO{sub 2}{sup 2+} molecular ions; our results are found to be very similar to those measured in double photoionisation experiments. (orig.)

  16. Coincident Observations of Surface Ozone and NMVOCs over Abu Dhabi

    Science.gov (United States)

    Abbasi, Naveed; Majeed, Tariq; Iqbal, Mazhar; Tarasick, David; Davies, Jonathan; Riemer, Daniel; Apel, Eric

    2016-07-01

    The vertical profiles of ozone are measured coincidently with non-methane volatile organic compounds (NMVOCs) at the meteorological site located at the Abu Dhabi international airport (latitude 24.45N; longitude 54.22E) during the years 2012 - 2014. Some of the profiles show elevated surface ozone >95 ppbv during the winter months (December, January and February). The ground-level NMVOCs obtained from the gas chromatography-flame ionization detection/mass spectrometry system also show elevated values of acetylene, ethane, propane, butane, pentane, benzene, and toluene. NMVOCs and ozone abundances in other seasons are much lower than the values in winter season. NMVOCs are emitted from an extensive number of sources in urban environments including fuel production, distribution, and consumption, and serve as precursor of ozone. Transport sources contribute a substantial portion of the NMVOC burden to the urban atmosphere in developed regions. Abu Dhabi is located at the edge of the Arabian Gulf and is highly affected by emissions from petrochemical industries in the neighboring Gulf region. The preliminary results indicate that wintertime enhancement in ozone is associated with large values of NMVOCs at Abu Dhabi. The domestic production of surface ozone is estimated from the combination of oxygen recombination and NMVOCs and compared with the data. It is estimated that about 40-50% of ozone in Abu Dhabi is transported from the neighbouring petrochemical industries. We will present ozone sounding and NMVOCs data and our model estimates of surface ozone, including a discussion on the high levels of the tropospheric ozone responsible for contaminating the air quality in the UAE. This work is supported by National Research Foundation, UAE.

  17. Gamma-gamma coincidence performance of LaBr3:Ce scintillation detectors vs HPGe detectors in high count-rate scenarios.

    Science.gov (United States)

    Drescher, A; Yoho, M; Landsberger, S; Durbin, M; Biegalski, S; Meier, D; Schwantes, J

    2017-04-01

    A radiation detection system consisting of two cerium doped lanthanum bromide (LaBr 3 :Ce) scintillation detectors in a gamma-gamma coincidence configuration has been used to demonstrate the advantages that coincident detection provides relative to a single detector, and the advantages that LaBr 3 :Ce detectors provide relative to high purity germanium (HPGe) detectors. Signal to noise ratios of select photopeak pairs for these detectors have been compared to high-purity germanium (HPGe) detectors in both single and coincident detector configurations in order to quantify the performance of each detector configuration. The efficiency and energy resolution of LaBr 3 :Ce detectors have been determined and compared to HPGe detectors. Coincident gamma-ray pairs from the radionuclides 152 Eu and 133 Ba have been identified in a sample that is dominated by 137 Cs. Gamma-gamma coincidence successfully reduced the Compton continuum from the large 137 Cs peak, revealed several coincident gamma energies characteristic of these nuclides, and improved the signal-to-noise ratio relative to single detector measurements. LaBr 3 :Ce detectors performed at count rates multiple times higher than can be achieved with HPGe detectors. The standard background spectrum consisting of peaks associated with transitions within the LaBr 3 :Ce crystal has also been significantly reduced. It is shown that LaBr 3 :Ce detectors have the unique capability to perform gamma-gamma coincidence measurements in very high count rate scenarios, which can potentially benefit nuclear safeguards in situ measurements of spent nuclear fuel. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Obesidade e asma: associação ou coincidência? Obesity and asthma: association or coincidence?

    Directory of Open Access Journals (Sweden)

    Daniella Fernandes Camilo

    2010-02-01

    Full Text Available OBJETIVO: A asma e a obesidade estão entre as maiores causas de morbidade na infância e adolescência. A obesidade precoce aumenta as chances de doenças crônicas degenerativas no adulto. Embora a concomitância de ambas as situações clínicas vem sendo demonstrada em vários estudos, os mecanismos intrínsecos dessa associação ainda são pouco conhecidos. Portanto, o objetivo deste artigo foi revisar os principais trabalhos sobre a associação de obesidade e asma e verificar se existe relação de causa e efeito entre ambas. FONTES DOS DADOS: Revisão sistemática baseada em bases de dados indexadas MEDLINE (PubMed e SciELO. Foram revisados artigos originais (transversal, caso-controle e prospectivo e meta-análises publicados no período de janeiro de 1998 a janeiro de 2008. Foram pesquisados estudos divulgados em língua inglesa, espanhola e portuguesa. SÍNTESE DOS DADOS: Embora existam muitos estudos sobre as crescentes prevalências da asma e da obesidade, poucos estabelecem relações de causa e efeito entre ambas. Os mecanismos fisiopatológicos e os fatores envolvidos nesse processo ainda são pouco conhecidos. CONCLUSÃO: O rigor metodológico em estudos futuros deverá buscar respostas para melhor entender se existe associação entre asma e obesidade, ou se a relação entre ambas as doenças é coincidência.OBJECTIVE: Asthma and obesity are among the major causes of morbidity in childhood and adolescence. Early obesity increases the chances of chronic degenerative diseases in adults. Although the concomitance or both clinical situations are being demonstrated in various studies, the intrinsic mechanisms of this association are still very little known. Therefore, the objective of this article was to review the main studies on the association of obesity and asthma and check if there is a cause-effect relation between them. SOURCES: Systematic review based on indexed data bases MEDLINE (PubMed and SciELO. Original articles

  19. Differential coincidence circuit in the 10-10 second region (1960)

    International Nuclear Information System (INIS)

    Van Zurk, R.; Grenoble-1 Univ., 38; Commissariat a l'Energie Atomique, Saclay

    1960-01-01

    A coincidence circuit of low resolution time using the differential coincidence Bay principle is described. It uses three 6BN6 tubes ordered to chronotron structure. Results with Radiotechnique 56 AVP photomultipliers and for 60 Co γ-γ coincidences are 4,6.10 -10 s (full width at half maximum) if the efficiency is ε = 40 per cent and also 7,2.10 -10 s if ε = 85 per cent. (author) [fr

  20. Description and performance characteristics for the neutron Coincidence Collar for the verification of reactor fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1981-08-01

    An active neutron interrogation method has been developed for the measurement of 235 U content in fresh fuel assemblies. The neutron Coincidence Collar uses neutron interrogation with an AmLi neutron source and coincidence counting the induced fission reaction neutrons from the 235 U. This manual describes the system components, operation, and performance characteristics. Applications of the Coincidence Collar to PWR and BWR types of reactor fuel assemblies are described

  1. Calibration of four neutron coincidence collars for PWR fresh fuel assemblies

    International Nuclear Information System (INIS)

    De Baere, P.; Carchon, R.; Smaers, G.; Smith, B.G.R.; Cranston, R.; Levy-Gorget, J.L.

    1988-05-01

    A measurement campaign was set up in order to calibrate four Neutron Coincidence Collars. For this purpose, a PWR fuel mock-up was used, as well as a series of real size PWR fuel assemblies. Calibration functions were set up, representing net real coincidence rate as a function of mass loading. All these calibration expressions have been referred to a general calibration expression, by applying some correction factors on the real coincidence count rate. (Author)

  2. The coincidence of IgA nephropathy and Fabry disease

    Directory of Open Access Journals (Sweden)

    Maixnerová Dita

    2013-01-01

    Full Text Available Abstract Background IgA nephropathy (IgAN is the most common glomerulonephritis, which may also coexist with other diseases. We present two patients with an unusual coincidence of IgAN and Fabry disease (FD. Case presentation A 26 year-old man underwent a renal biopsy in February 2001. Histopathology showed very advanced IgAN and vascular changes as a result of hypertension. Because of his progressive renal insufficiency the patient began hemodialysis in August 2001. By means of the blood spot test screening method the diagnosis of FD was suspected. Low activity of alpha-galactosidase A in the patient’s plasma and leukocytes and DNA analysis confirmed the diagnosis of FD. Enzyme replacement therapy started in July 2004. Then the patient underwent kidney transplantation in November 2005. Currently, his actual serum creatinine level is 250 μmol/l. Other organ damages included hypertrophic cardiomyopathy, neuropathic pain and febrile crisis. After enzyme replacement therapy, myocardial hypertrophy has stabilized and other symptoms have disappeared. No further progression of the disease has been noted. The other patient, a 30 year-old woman, suffered from long-term hematuria with a good renal function. Recently, proteinuria (2.6 g/day appeared and a renal biopsy was performed. Histopathology showed IgAN with remarkably enlarged podocytes. A combination of IgAN and a high suspicion of FD was diagnosed. Electron microscopy revealed dense deposits in paramesangial areas typical for IgAN and podocytes with inclusive zebra bodies and myelin figures characteristic of FD. FD was confirmed by the decreased alpha-galactosidase A activity in plasma and leukocytes and by DNA and RNA analysis. Enzyme replacement therapy and family screening were initiated. Conclusions Our results emphasize the role of complexity in the process of diagnostic evaluation of kidney biopsy samples. Electron microscopy represents an integral part of histopathology, and genetic

  3. Studies on the true coincidence correction in measuring filter samples by gamma spectrometry

    CERN Document Server

    Lian Qi; Chang Yong Fu; Xia Bing

    2002-01-01

    The true coincidence correction in measuring filter samples has been studied by high efficiency HPGe gamma detectors. The true coincidence correction for a specific three excited levels de-excitation case has been analyzed, and the typical analytical expressions of true coincidence correction factors have been given. According to the measured relative efficiency on the detector surface with 8 'single' energy gamma emitters and efficiency of filter samples, the peak and total efficiency surfaces are fitted. The true coincidence correction factors of sup 6 sup 0 Co and sup 1 sup 5 sup 2 Eu calculated by the efficiency surfaces agree well with experimental results

  4. Coincidence-anticipation timing and reaction time in youth tennis and table tennis players.

    Science.gov (United States)

    Ak, Emre; Koçak, Settar

    2010-06-01

    The purpose of this study was to compare the coincidence-anticipation timing and reaction times (RT) of 10- to 14-year-old tennis and table tennis players and examine possible sex differences. 107 (51.4%) tennis and 101 (48.6%) table tennis players participated in this study. Players were compared on coincidence-anticipation timing and reaction time. Tennis players performed with less error in the coincidence-anticipation timing task than table tennis players, whereas table tennis players had lower mean reaction time than tennis players. It was also found that male players made fewer errors in the coincidence-anticipation timing task than their female counterparts.

  5. A COSMIC COINCIDENCE: THE POWER-LAW GALAXY CORRELATION FUNCTION

    International Nuclear Information System (INIS)

    Watson, Douglas F.; Berlind, Andreas A.; Zentner, Andrew R.

    2011-01-01

    are satellites, the relative difference in mass between the halos of isolated galaxies and halos that contain a single satellite on average, and the rareness of halos that host galaxies. These pieces are intertwined and we find no simple, universal rule for which a power law ξ(r) will occur. However, we do show that the physics responsible for setting the galaxy content of halos do not care about the conditions needed to achieve a power law ξ(r) and that these conditions are met only in a narrow mass and redshift range. We conclude that the power-law nature of ξ(r) for L * and fainter galaxy samples at low redshift is a cosmic coincidence.

  6. A Web-based Google-Earth Coincident Imaging Tool for Satellite Calibration and Validation

    Science.gov (United States)

    Killough, B. D.; Chander, G.; Gowda, S.

    2009-12-01

    The Group on Earth Observations (GEO) is coordinating international efforts to build a Global Earth Observation System of Systems (GEOSS) to meet the needs of its nine “Societal Benefit Areas”, of which the most demanding, in terms of accuracy, is climate. To accomplish this vision, satellite on-orbit and ground-based data calibration and validation (Cal/Val) of Earth observation measurements are critical to our scientific understanding of the Earth system. Existing tools supporting space mission Cal/Val are often developed for specific campaigns or events with little desire for broad application. This paper describes a web-based Google-Earth based tool for the calculation of coincident satellite observations with the intention to support a diverse international group of satellite missions to improve data continuity, interoperability and data fusion. The Committee on Earth Observing Satellites (CEOS), which includes 28 space agencies and 20 other national and international organizations, are currently operating and planning over 240 Earth observation satellites in the next 15 years. The technology described here will better enable the use of multiple sensors to promote increased coordination toward a GEOSS. The CEOS Systems Engineering Office (SEO) and the Working Group on Calibration and Validation (WGCV) support the development of the CEOS Visualization Environment (COVE) tool to enhance international coordination of data exchange, mission planning and Cal/Val events. The objective is to develop a simple and intuitive application tool that leverages the capabilities of Google-Earth web to display satellite sensor coverage areas and for the identification of coincident scene locations along with dynamic menus for flexibility and content display. Key features and capabilities include user-defined evaluation periods (start and end dates) and regions of interest (rectangular areas) and multi-user collaboration. Users can select two or more CEOS missions from a

  7. Complete intrinsic coincident polarimetry using stacked organic photovoltaics

    Science.gov (United States)

    Gupta Roy, S.; Awartani, O. M.; Sen, P.; O'Connor, B. T.; Kudenov, M. W.

    2015-09-01

    Measuring the 2 dimensional Stokes vector, to determine the polarization state of light, finds application in multiple areas, including the characterization of aerosol size distributions, target identification, quality control by evaluating the distribution of stress birefringence, resolving data channels in telecommunications, and for evaluating biological tissues in medical imaging. Conventional methods, such as channeled and division of focal plane polarimeters, usually limit spatial resolution, while others, like division of aperture or division of amplitude polarimeters, have higher complexity and less compactness. To help solve these issues, we have developed a system that uses semitransparent organic photovoltaics (OPVs) as photodetectors. The active area of the devices consist of biaxially oriented polymer films, which enables the device to preferentially absorb certain polarized states of incident light, depending on the orientation of the polymer chains. Taking advantage of the cells' transparency and ease of processing, compared to inorganic materials, enables multiple devices to be "stacked" along the optical axis. Presently, experiments have been conducted to detect linear polarization states of light. We use three stacked OPVs, where each device can measure one of the first three Stokes parameters simultaneously, thereby ensuring high spatial and temporal resolution with inherent spatial registration. In this paper, the fabrication of the OPVs and the design and calibration technique is documented, along with experimental data, supporting the hypothesis.

  8. Systemic lupus erythematosus and pemphigus vulgaris: association or coincidence.

    Science.gov (United States)

    Calebotta, A; Cirocco, A; Giansante, E; Reyes, O

    2004-01-01

    Few cases have been published relating systemic lupus erythematosus (SLE) and pemphigus vulgaris (PV). We describe a patient with this association. A 35-year old woman who started to develop persistent pain and morning stiffness of proximal inter and metacarpo-phalangeal joints. During the following year, the patient recalled the onset of blisters on both legs, face, arms and thorax, as well as erosions appearing on oral mucous membranes. We observed generalized multiple erosions on her trunk and legs, flaccid bullae located on her right thigh and multiple erosions on oral mucous membranes. A skin biopsy reported PV Direct immunofluorescence on the perilesional skin specimen, showed beehive intercellular IgG deposits in the epidermis (+++), suggesting PV; granular discontinuous IgM and C3 deposits in the dermal-epidermal union (+++), suggesting SLE. Direct immunofluorescence of the healthy unexposed skin specimen, reported granular discontinuous IgG deposits in the dermal-epidermal union and beehive intercellular IgG deposits in the lower levels of the epidermis (+++); granular continuous IgM deposits in the dermal-epidermal union (+++). The results of rheumatic studies were obtained as follows: ANA :3 +, Anti-DNA, Anti-Sm, Anti-Ro and Anti-La :4 + . The definite diagnosis was PVand SLE. Treatment with 50 mg of prednisone daily with good evolution.

  9. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen

    2017-12-22

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  10. Experimental study on the possibility of reducing background for the gamma coincidence spectrometer with high pure germanium detectors

    International Nuclear Information System (INIS)

    Dinh Sy Hien

    2012-01-01

    Gamma coincidence spectrometers with HPGe detectors are used for environmental research, nuclear reactions (n, γ), (n, 2 γ) due to Compton backgrounds of their gamma spectra are very low. In this work, three types of coincidence spectrometers such as gamma coincidence spectrometer, gamma coincidence spectrometers with TAC and sum coincidence spectrometer using HPGe are described. Some experimental results obtained by using gamma coincidence spectrometers are presented. Especially, taking advantages of the software and hardware of the sum coincidence spectrometer used for research of nuclear reactions (n, γ), (n, 2 γ), we have converted the spectrometer to one with very low background level. (author)

  11. Coupled Coincidence Point and Coupled Common Fixed Point Theorems in Partially Ordered Metric Spaces with -Distance

    Directory of Open Access Journals (Sweden)

    Ilić Dejan

    2010-01-01

    Full Text Available We introduce the concept of a -compatible mapping to obtain a coupled coincidence point and a coupled point of coincidence for nonlinear contractive mappings in partially ordered metric spaces equipped with -distances. Related coupled common fixed point theorems for such mappings are also proved. Our results generalize, extend, and unify several well-known comparable results in the literature.

  12. Estimation of coincidence and correlation in non-analogous Monte Carlo particle transport - 159

    International Nuclear Information System (INIS)

    Szieberth, M.; Leen Kloosterman, J.

    2010-01-01

    The conventional non-analogous Monte Carlo methods are optimized to preserve the mean value of the distributions and therefore they are not suited for non-Boltzmann problems like the estimation of coincidences or correlations. This paper presents a general method called history splitting for the non-analogous estimation of such quantities. The basic principle of the method is that a non-analogous particle history can be interpreted as a collection of analogous histories with different weights according to the probability of their realization. Calculations with a simple Monte Carlo program for a pulse-height-type estimator prove that the method is feasible and provides unbiased estimation. Different variance reduction techniques have been tried with the method and Russian roulette turned out to be ineffective in high multiplicity systems. An alternative history control method is applied instead. Simulation results of a Feynman-α measurement shows that even the reconstruction of the higher moments is possible with the history splitting method, which makes the simulation of neutron noise measurements feasible. (authors)

  13. The ENSO-pandemic influenza connection: coincident or causal?

    Science.gov (United States)

    Shaman, J. L.; Lipsitch, M.

    2011-12-01

    The El Niño-Southern Oscillation (ENSO) is a coupled ocean-atmosphere system in the tropical Pacific, which affects weather conditions, including temperatures, precipitation, winds and storm activity, across the planet. ENSO has two extreme phases marked by either warmer (El Niño) or cooler (La Niña) than average sea surface temperatures in the central equatorial Pacific. We find that the 4 most recent human influenza pandemics (1918, 1957, 1968, 2009), all of which were first identified in boreal spring or summer, were preceded by La Niña conditions in the equatorial Pacific. Changes in ENSO have been shown to alter the migration, stopover time, fitness and interspecies mixing of migratory birds, and consequently likely affect their mixing with domestic animals. We hypothesize that La Niña conditions bring divergent influenza subtypes together in some parts of the world and favor the reassortment of influenza through simultaneous multiple infection of individual hosts and the generation of novel pandemic strains. We propose approaches to test this hypothesis using influenza population genetics, virus prevalence in various host species, and avian migration patterns.

  14. Evaluation of accidental coincidences for time-differential Moessbauer-spectroscopy

    International Nuclear Information System (INIS)

    Alflen, M.; Meyer, W.

    1995-01-01

    The accidental coincidences of a measuring system based on time-to-amplitude conversion are considered in some detail for the case of low starting and high stopping rates. Two types of accidental coincidences are distinguished, those carrying time information and those without time information. Neglecting any deadtime effects of the detectors, analytical expressions for the calculation of the time distribution of the random coincidences are evaluated. The analytical expressions have been confirmed by Monte Carlo simulations. The procedure is applied to time-differential Moessbauer spectroscopy in order to extract the time spectra of true coincidences. The measured spectrum in a time channel turns out to be a superposition of the true spectrum (true coincidences), a time integral spectrum (random coincidences), and a weighted superposition of true spectra of other time channels (random but time carrying information). A measurement with a single line 57 Co/Rh-source and single line K[Fe(CN) 6 ].3H 2 O-absorber with stopping rates of 1 MBq shows agreement between the theoretical time-filtered spectra and the corrected measured spectra of true coincidences. ((orig.))

  15. Testing the Cosmic Coincidence Problem and the Nature of Dark Energy

    International Nuclear Information System (INIS)

    Dalal, Neal; Abazajian, Kevork; Jenkins, Elizabeth; Manohar, Aneesh V.

    2001-01-01

    Dark energy models which alter the relative scaling behavior of dark energy and matter could provide a natural solution to the cosmic coincidence problem -- why the densities of dark energy and dark matter are comparable today. A generalized class of dark energy models is introduced which allows noncanonical scaling of the ratio of dark matter and dark energy with the Robertson-Walker scale factor a(t) . We show that determining whether there is a coincidence problem, and the extent of cosmic coincidence, can be addressed by several forthcoming experiments

  16. Instrument limitation of accuracy of absolute measurement by method of 4π beta-gamma coincidence

    International Nuclear Information System (INIS)

    Plkh, J.

    1979-01-01

    Accuracy is discussed of determination of coincidence channels dead-time in 4π β-γ installation and determination of coincidence resolution time as well as conditions for determination and accuracy of these parameters. Conditions are considered under which these parameters have not been determined and there is wrong performance of the installation. Special attention was paid to the electronic circuit of the γ-channel. It has been shown that as a result of wrong performance of electronic circuit a new type of wrong coincidence appeared [ru

  17. Study of the coincidences between the gravitational wave detectors EXPLORER and NAUTILUS in 2001

    International Nuclear Information System (INIS)

    Astone, P; Babusci, D; Bassan, M; Bonifazi, P; Carelli, P; Cavallari, G; Coccia, E; Cosmelli, C; D'Antonio, S; Fafone, V; Federici, G; Frasca, S; Giordano, G; Marini, A; Minenkov, Y; Modena, I; Modestino, G; Moleti, A; Pallottino, G V; Pizzella, G; Quintieri, L; Rocchi, A; Ronga, F; Terenzi, R; Torrioli, G; Visco, M

    2002-01-01

    We report the result from a search for bursts of gravitational waves using data collected by the cryogenic resonant detectors EXPLORER and NAUTILUS during 2001 for a total measuring time of 90 days. With these data we repeated the coincidence search performed on the 1998 data (which showed a small coincidence excess) applying data analysis algorithms based on known physical characteristics of the detectors. With the 2001 data, a new interesting coincidence excess is found when the detectors are favourably oriented with respect to the galactic disc

  18. The IAEA neutron coincidence counting (INCC) and the DEMING least-squares fitting programs

    International Nuclear Information System (INIS)

    Krick, M.S.; Harker, W.C.; Rinard, P.M.; Wenz, T.R.; Lewis, W.; Pham, P.; Ridder, P. de

    1998-01-01

    Two computer programs are described: (1) the INCC (IAEA or International Neutron Coincidence Counting) program and (2) the DEMING curve-fitting program. The INCC program is an IAEA version of the Los Alamos NCC (Neutron Coincidence Counting) code. The DEMING program is an upgrade of earlier Windows reg-sign and DOS codes with the same name. The versions described are INCC 3.00 and DEMING 1.11. The INCC and DEMING codes provide inspectors with the software support needed to perform calibration and verification measurements with all of the neutron coincidence counting systems used in IAEA inspections for the nondestructive assay of plutonium and uranium

  19. Unexpected decline in tuberculosis cases coincident with economic recession -- United States, 2009

    Directory of Open Access Journals (Sweden)

    Winston Carla A

    2011-11-01

    Full Text Available Abstract Background Since 1953, through the cooperation of state and local health departments, the U.S. Centers for Disease Control and Prevention (CDC has collected information on incident cases of tuberculosis (TB disease in the United States. In 2009, TB case rates declined -11.4%, compared to an average annual -3.8% decline since 2000. The unexpectedly large decline raised concerns that TB cases may have gone unreported. To address the unexpected decline, we examined trends from multiple sources on TB treatment initiation, medication sales, and laboratory and genotyping data on culture-positive TB. Methods We analyzed 142,174 incident TB cases reported to the U. S. National Tuberculosis Surveillance System (NTSS during January 1, 2000-December 31, 2009; TB control program data from 59 public health reporting areas; self-reported data from 50 CDC-funded public health laboratories; monthly electronic prescription claims for new TB therapy prescriptions; and complete genotyping results available for NTSS cases. Accounting for prior trends using regression and time-series analyses, we calculated the deviation between observed and expected TB cases in 2009 according to patient and clinical characteristics, and assessed at what point in time the deviation occurred. Results The overall deviation in TB cases in 2009 was -7.9%, with -994 fewer cases reported than expected (P Conclusions Our assessments show that the decline in reported TB was not an artifact of changes in surveillance methods; rather, similar declines were found through multiple data sources. While the steady decline of TB cases before 2009 suggests ongoing improvement in TB control, we were not able to identify any substantial change in TB control activities or TB transmission that would account for the abrupt decline in 2009. It is possible that other multiple causes coincident with economic recession in the United States, including decreased immigration and delayed access to

  20. Comparison of satellite reflectance algorithms for estimating chlorophyll-a in a temperate reservoir using coincident hyperspectral aircraft imagery and dense coincident surface observations

    Science.gov (United States)

    We analyzed 10 established and 4 new satellite reflectance algorithms for estimating chlorophyll-a (Chl-a) in a temperate reservoir in southwest Ohio using coincident hyperspectral aircraft imagery and dense water truth collected within one hour of image acquisition to develop si...

  1. X-ray fluorescence/Auger-electron coincidence spectroscopy of vacancy cascades in atomic argon

    International Nuclear Information System (INIS)

    Arp, U.

    1996-01-01

    Argon L 2.3 -M 2.3 M 2.3 Auger-electron spectra were measured in coincidence with Kα fluorescent x-rays in studies of Ar K-shell vacancy decays at several photon energies above the K-threshold and on the 1s-4p resonance in atomic argon. The complex spectra recorded by conventional electron spectroscopy are greatly simplified when recorded in coincidence with fluorescent x-rays, allowing a more detailed analysis of the vacancy cascade process. The resulting coincidence spectra are compared with Hartree-Fock calculations which include shake-up transitions in the resonant case. Small energy shifts of the coincidence electron spectra are attributed to post-collision interaction with 1s photoelectrons

  2. High proportion of smaller ranged hummingbird species coincides with ecological specialization across the Americas

    DEFF Research Database (Denmark)

    Sonne, Jesper; Martín González, Ana M.; Maruyama, Pietro K.

    2016-01-01

    Ecological communities that experience stable climate conditions have been speculated to preserve more specialized interspecific associations and have higher proportions of smaller ranged species (SRS). Thus, areas with disproportionally large numbers of SRS are expected to coincide geographicall...

  3. A gamma-gamma coincidence spectrometric method for rapid characterization of uranium isotopic fingerprints

    International Nuclear Information System (INIS)

    Weihua Zhang; Jing Yi; Pawel Mekarski; Kurt Ungar; Barry Hauck; Kramer, G.H.

    2011-01-01

    This paper reports on initial efforts for uranium isotopic analysis using gamma-rays and X-ray fluorescence coincidence. In this study, a gamma-gamma coincidence spectrometry was developed. The spectrometry consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The developed spectrometry was optimized according to the considerations of output count rate and gamma peak energy resolution. It has been demonstrated that the spectrometry provides an effective method of assessing the content of uranium isotopes for nuclear materials. The main advantages of this approach over the conventional gamma spectrometry include the fact that 235 U enrichment can be graphically characterized by its unique coincidence 'fingerprints'. The method could be further developed for fast uranium isotope verification with an established gamma-gamma coincidence spectral imaging library by various nuclear materials. (author)

  4. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  5. Reproduction of the coincidence effect in gamma ray spectrometry by using Monte Carlo method

    International Nuclear Information System (INIS)

    Park, S. H.; Kim, J. K.; Lee, S. H.

    2001-01-01

    Scintillation detector such as NaI(TI), or semiconductor detector, such as HPGe, are used for Measurement/Assessment of the radiation type and radiation activity. The measured energy spectrum are used for measuring the radiation type and activity. Corrections for true coincidence due to emit more than 2 photons at the same time and random coincidence due to measuring system when increasing of the radiation intensity. For accurate assessment, measurement with adequate measure system is performed, and corrections for coincidence are performed in the hardware aspect and software aspect. In general, there are limitations or difficulties in measurement of radiation assessment, computational simulation is instead used. In simulation, it has much advantages than measurement in technically, timely, and financially, it is widely used instead of measurement. In this study, the method to reproduce of the coincidence effect was proposed by using monte carlo method

  6. Subtraction of random coincidences in γ-ray spectroscopy: A new approach

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Basu, S.K.; Garg, U.; Ray, S.; Sinha, A.K.; Zhu, S.

    2006-01-01

    A new analytical method for estimation and subsequent subtraction of random coincidences has been developed. It utilizes the knowledge of the counts in the main diagonal of a background-subtracted symmetric data set for the estimation of the events originating from random coincidences. This procedure has been successfully applied to several data sets. It could be a valuable tool for low-fold data sets, especially for low-cross-section events

  7. A method for measuring the energy spectrum of coincidence events in positron emission tomography.

    Science.gov (United States)

    Goertzen, Andrew L; Stout, David B; Thompson, Christopher J

    2010-01-21

    Positron emission tomography (PET) system energy response is typically characterized in singles detection mode, yet there are situations in which the energy spectrum of coincidence events might be different than the spectrum measured in singles mode. Examples include imaging with isotopes that emit a prompt gamma in coincidence with a positron emission, imaging with low activity in a LSO/LYSO-based cameras, in which the intrinsic activity is significant, and in high scatter situations where the two 511 keV photons have different scattering probabilities (i.e. off-center line source). The ability to accurately measure the energy spectrum of coincidence events could be used for validating simulation models, optimizing energy discriminator levels and examining scatter models and corrections. For many PET systems operating in coincidence mode, the only method available for estimating the energy spectrum is to step the lower and upper level discriminators (LLD and ULD). Simple measurement techniques such as using a narrow sliding energy window or stepping only the LLD will not yield a spectrum of coincidence events that is accurate for cases where there are different energy components contributing to the spectrum. In this work we propose a new method of measuring the energy spectrum of coincidence events in PET based on a linear combination of two sets of coincident count measurements: one made by stepping the LLD and one made by stepping the ULD. The method was tested using both Monte Carlo simulations of a Siemens microPET R4 camera and measured data acquired on a Siemens Inveon PET camera. The results show that our energy spectrum calculation method accurately measures the coincident energy spectra for cases including the beta/gamma spectrum of the (176)Lu intrinsic activity present in the LSO scintillator crystals, a (68)Ge source and an (124)I source (in which there are prompt gamma-rays emitted together with the positron).

  8. Dynamic remodeling of lipids coincides with dengue virus replication in the midgut of Aedes aegypti mosquitoes.

    Directory of Open Access Journals (Sweden)

    Nunya Chotiwan

    2018-02-01

    Full Text Available We describe the first comprehensive analysis of the midgut metabolome of Aedes aegypti, the primary mosquito vector for arboviruses such as dengue, Zika, chikungunya and yellow fever viruses. Transmission of these viruses depends on their ability to infect, replicate and disseminate from several tissues in the mosquito vector. The metabolic environments within these tissues play crucial roles in these processes. Since these viruses are enveloped, viral replication, assembly and release occur on cellular membranes primed through the manipulation of host metabolism. Interference with this virus infection-induced metabolic environment is detrimental to viral replication in human and mosquito cell culture models. Here we present the first insight into the metabolic environment induced during arbovirus replication in Aedes aegypti. Using high-resolution mass spectrometry, we have analyzed the temporal metabolic perturbations that occur following dengue virus infection of the midgut tissue. This is the primary site of infection and replication, preceding systemic viral dissemination and transmission. We identified metabolites that exhibited a dynamic-profile across early-, mid- and late-infection time points. We observed a marked increase in the lipid content. An increase in glycerophospholipids, sphingolipids and fatty acyls was coincident with the kinetics of viral replication. Elevation of glycerolipid levels suggested a diversion of resources during infection from energy storage to synthetic pathways. Elevated levels of acyl-carnitines were observed, signaling disruptions in mitochondrial function and possible diversion of energy production. A central hub in the sphingolipid pathway that influenced dihydroceramide to ceramide ratios was identified as critical for the virus life cycle. This study also resulted in the first reconstruction of the sphingolipid pathway in Aedes aegypti. Given conservation in the replication mechanisms of several

  9. Standardization of 59Fe 4πβ(LS)-γcoincidence counting with digital sampling method

    International Nuclear Information System (INIS)

    Agusbudiman, A.; Lee, K. B.; Lee, J. M.; Park, T. S.

    2014-01-01

    The radionuclide 59Fe decays with a half-life of 44.494(12) days, by several beta minus emission to the ground state and to four excited states of 59 Co, mainly to the 1099 keV and 1291 keV (Bé et al., 2004). The activity of 59 Fe was measured by 4 πβ(LS)-γ coincidence counting method with digital sampling technique. A gamma spectrometry analysis was also conducted to check the impurities of the source. As comparison, the activity were also measured by using the 4πβ(PC)-γ coincidence counting system and 4πβ (LS)-γ anti-coincidence method. The radionuclide 59Fe has been standardized using the 4πβ(LS)-γcoincidence counting with digital sampling method. The result was in a good agreement with the result from 4πβ(PC)-γ coincidence counting and the 4πβ(LS)-γ anti-coincidence method

  10. An investigation of a coincidence detection system for an all-digital small animal PET scanner

    International Nuclear Information System (INIS)

    Liu Wei; Chen Yuanbao; Long Anwen; Chen Xin; Wu Zhongyi; Zhang Yongxue; Xie Qingguo

    2013-01-01

    Objective: To investigate and design a coincidence detection system for an all-digital small animal PET scanner and evaluate its preliminary performance properties. Methods: This coincidence module adopted a coincidence identification mode based on singles data in list-mode.Using digital signal processing technology, energy calibration, crystal identification, timing alignment and coincidence events extraction were performed on singles data in list-mode. The obtained data could be used for image reconstruction. Results: The 13 × 13 crystal array was well recognized by the position histogram of one lutetium yttrium orthosilicate (LYSO) crystal block. In the coincidence timing histogram of the micro-Derenzo phantom, 1.36 ns full width at half maximum was obtained. The rods with a diameter of 1.2 mm were clearly displayed in the reconstructed image of the micro-Derenzo phantom. Conclusion: The coincidence module can provide satisfactory performance to meet the design needs of an all-digital small animal PET scanner. (authors)

  11. Multiple Pregnancy

    Science.gov (United States)

    ... Education & Events Advocacy For Patients About ACOG Multiple Pregnancy Home For Patients Search FAQs Multiple Pregnancy Page ... Multiple Pregnancy FAQ188, July 2015 PDF Format Multiple Pregnancy Pregnancy How does multiple pregnancy occur? What are ...

  12. Multiple sclerosis; Multiple Sklerose

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Kuehn, A.L.; Backens, M.; Papanagiotou, P. [Universitaet des Saarlandes, Abteilung fuer Diagnostische und Interventionelle Neuroradiologie, Radiologische Klinik, Homburg/Saar (Germany); Shariat, K. [Universitaet des Saarlandes, Klinik fuer Neurochirurgie, Homburg/Saar (Germany); Kostopoulos, P. [Universitaet des Saarlandes, Klinik fuer Neurologie, Homburg/Saar (Germany)

    2008-06-15

    Multiple sclerosis is the most common chronic inflammatory disease of myelin with interspersed lesions in the white matter of the central nervous system. Magnetic resonance imaging (MRI) plays a key role in the diagnosis and monitoring of white matter diseases. This article focuses on key findings in multiple sclerosis as detected by MRI. (orig.) [German] Die Multiple Sklerose (MS) ist die haeufigste chronisch-entzuendliche Erkrankung des Myelins mit eingesprengten Laesionen im Bereich der weissen Substanz des zentralen Nervensystems. Die Magnetresonanztomographie (MRT) hat bei der Diagnosestellung und Verlaufskontrolle eine Schluesselrolle. Dieser Artikel befasst sich mit Hauptcharakteristika der MR-Bildbebung. (orig.)

  13. Threshold Photoelectron Photoion Coincidence (TPEPICO) Studies. The Road to ± 0.1 kJ/mol Thermochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Baer, Tomas [Univ. of North Carolina, Chapel Hill, NC (United States)

    2013-10-14

    The threshold photoelectron photoion coincidence (TPEPICO) technique is utilized to investigate the dissociation dynamics and thermochemistry of energy selected medium to large organic molecular ions. The reactions include parallel and consecutive steps that are modeled with the statistical theory in order to extract dissociation onsets for multiple dissociation paths. These studies are carried out with the aid of molecular orbital calculations of both ions and the transition states connecting the ion structure to their products. The results of these investigations yield accurate heats of formation of ions, free radicals, and stable molecules. In addition, they provide information about the potential energy surface that governs the dissociation process. Isomerization reactions prior to dissociation are readily inferred from the TPEPICO data.

  14. Development of an analysis methodology applied to 4πβ-γ software coincidence data acquisition system

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro da Silva; Toledo, Fabio de

    2009-01-01

    The present work describes the new software methodology under development at the IPEN Nuclear Metrology Laboratory for radionuclide standardizations with 4πβ-γ coincidence technique. The software includes the Coincidence Graphic User Interface (GUI) and the Coincidence Analysis Program. The first results for a 60 Co sample measurement are discussed and compared to the results obtained with two different conventional coincidence systems. (author)

  15. Determination of trace elements in scallop and fish otolith by instrumental neutron activation analysis using anti-coincidence and coincidence counting methods

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    2005-01-01

    Trace element concentrations in scallop reference material and fish otolith certified reference materials prepared at the National Institute for Environmental Studies (NIES) of Japan were determined by instrumental neutron activation analysis (INAA). Nine aliquots of scallop sample (ca. 252∼507 mg) and five aliquots of fish otolith sample (ca. 502 ∼ 988 mg) and comparative standards were irradiated for a short time (10 s) at a thermal neutron flux of 1.5 x 10 12 n cm -2 s -1 (pneumatic transfer) and for a long time (6 h) at a thermal neutron flux of 3.7 x 10 12 n cm -2 s -1 (central thimble) in the Rikkyo University Research Reactor (100 kW). The irradiated samples were measured by conventional γ-ray spectrometry using a coaxial Ge detector, and by anti-coincidence and coincidence γ-ray spectrometry with a coaxial Ge detector and a well-type NaI (Tl) detector to determine as many trace elements as possible with high sensitivity. The concentrations of 34 elements of the NIES No.15 scallop reference material and 16 elements of the NIES No.22 fish otolith CRM were determined. Using the coincidence counting method to determine Se, Ba and Hf, the lower limit of the determination was improved by 2 times compared with the conventional counting method. (author)

  16. Comparison of Satellite Reflectance Algorithms for Estimating Phycocyanin Values and Cyanobacterial Total Biovolume in a Temperate Reservoir Using Coincident Hyperspectral Aircraft Imagery and Dense Coincident Surface Observations

    Directory of Open Access Journals (Sweden)

    Richard Beck

    2017-05-01

    Full Text Available We analyzed 27 established and new simple and therefore perhaps portable satellite phycocyanin pigment reflectance algorithms for estimating cyanobacterial values in a temperate 8.9 km2 reservoir in southwest Ohio using coincident hyperspectral aircraft imagery and dense coincident water surface observations collected from 44 sites within 1 h of image acquisition. The algorithms were adapted to real Compact Airborne Spectrographic Imager (CASI, synthetic WorldView-2, Sentinel-2, Landsat-8, MODIS and Sentinel-3/MERIS/OLCI imagery resulting in 184 variants and corresponding image products. Image products were compared to the cyanobacterial coincident surface observation measurements to identify groups of promising algorithms for operational algal bloom monitoring. Several of the algorithms were found useful for estimating phycocyanin values with each sensor type except MODIS in this small lake. In situ phycocyanin measurements correlated strongly (r2 = 0.757 with cyanobacterial sum of total biovolume (CSTB allowing us to estimate both phycocyanin values and CSTB for all of the satellites considered except MODIS in this situation.

  17. Portable multiplicity counter

    Science.gov (United States)

    Newell, Matthew R [Los Alamos, NM; Jones, David Carl [Los Alamos, NM

    2009-09-01

    A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

  18. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  19. Digital Pulse Shape Analysis with Phoswich Detectors to Simplify Coincidence Measurements of Radioactive Xenon

    International Nuclear Information System (INIS)

    Hennig, Wolfgang; Tan, Hui; Warburton, William K.; McIntyre, Justin I.

    2005-01-01

    The Comprehensive Nuclear-Test-Ban Treaty establishes a network of monitoring stations to detect radioactive Xenon in the atmosphere from nuclear weapons testing. One such monitoring system is the Automated Radio-xenon Sampler/Analyzer (ARSA) developed at Pacific Northwest National Laboratory, which uses a complex arrangement of separate beta and gamma detectors to detect beta-gamma coincidences from the Xe isotopes of interest. The coincidence measurement is very sensitive, but the large number of detectors and photomultiplier tubes require careful calibration which makes the system hard to use. It has been suggested that beta-gamma coincidences could be detected with only a single photomultiplier tube and electronics channel by using a phoswich detector consisting of optically coupled beta and gamma detectors (Ely, 2003). In that work, rise time analysis of signals from a phoswich detector was explored as a method to determine if interactions occurred in either the beta or the gamma detector or in both simultaneously. However, this approach was not able to detect coincidences with the required sensitivity or to measure the beta and gamma energies with sufficient precision for Xenon monitoring. In this paper, we present a new algorithm to detect coincidences by pulse shape analysis of the signals from a BC-404/CsI(Tl) phoswich detector. Implemented on fast digital readout electronics, the algorithm achieves clear separation of beta only, gamma only and coincidence events, accurate measurement of both beta and gamma energies, and has an error rate for detecting coincidences of less than 0.1%. Monte Carlo simulations of radiation transport and light collection were performed to optimize design parameters for a replacement detector module for the ARSA system, obtaining an estimated coincidence detection efficiency of 82-92% and a background rejection rate better than 99%. The new phoswich/pulse shape analysis method is thus suitable to simplify the existing ARSA

  20. A Nal-Nal Coincidence Low Background Counting System for Low-Level gamma -Ray Measurements

    International Nuclear Information System (INIS)

    Sharshar, T.

    1998-01-01

    A Nal-Nal coincidence low background counting system has been constructed to be used in neutron activation analysis and radioenvironmental measurements. The slow timing technique, using the Constant Fraction Timing Single Channel Analyzer and Coincidence unit, was used in the present system. To improve the coincidence counting efficiency of the system, four 3.8cm x 2.5cmNaI(Tl) detectors were used. A special scintillation preamplifier with three inputs and one output was constructed for summing the outputs of three PM tubes. The performance of the new system was tested using radioactive point sources and some environmental samples. The system characteristics and its special features are discussed

  1. Application of multiparameter coincidence spectrometry using a Ge detectors array to neutron activation analysis

    International Nuclear Information System (INIS)

    Hatsukawa, Y.; Oshima, M.; Hayakawa, T.; Toh, Y.; Shinohara, N.

    2002-01-01

    The method of multiparameter coincidence spectrometry based on γ-γ coincidence is widely used for the nuclear structure studies, because of its high sensitivity to γ-rays. In this study, feasibility of the method of multiparameter coincidence spectrometry for analytical chemistry was examined. Two reference igneous rock samples (JP-1, JB-1a) issued by the Geological Survey of Japan were irradiated at a research reactor, and the γ-rays from the radioisotopes produced via neutron capture reactions were measured using an array of 12 Ge detectors with BGO Compton suppressors, GEMINI. Simultaneously 24 elements were analyzed without chemical separation. The observed smallest component was Eu contained in JP-1 with abundance of 4 ppb

  2. Instrumentation and data handling. I. Positron coincidence imaging with the TOKIM system

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    In addition to the conventional singles mode of operation, the TOKIM system's two Anger-type gamma cameras may be used in the (stationary, 180 0 opposition) coincidence mode, making it possible to achieve tomographic imaging with three-dimensional spatial resolution and high detection sensitivity, utilizing β + emitting radioisotopes. This method, however, suffers from certain inherent limitations. Our efforts during this past year to improve upon the TOKIM imaging capability in the β + mode have been directed towards the reduction of the limitations by the following means: the removal of out of focal plane image contributions through a computerized iterative correction procedure, coupled with coincidence aperture limitation to achieve uniform sensitivity across a reasonable portion of the detector pair diameter, and the application of Muehllehner's graded filter approach to the TOKIM to increase the ratio of usable coincidence events versus singles count rate

  3. Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Cowles, Christian C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Siciliano, Edward R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-10-01

    The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

  4. Convergent input from brainstem coincidence detectors onto delay-sensitive neurons in the inferior colliculus.

    Science.gov (United States)

    McAlpine, D; Jiang, D; Shackleton, T M; Palmer, A R

    1998-08-01

    Responses of low-frequency neurons in the inferior colliculus (IC) of anesthetized guinea pigs were studied with binaural beats to assess their mean best interaural phase (BP) to a range of stimulating frequencies. Phase plots (stimulating frequency vs BP) were produced, from which measures of characteristic delay (CD) and characteristic phase (CP) for each neuron were obtained. The CD provides an estimate of the difference in travel time from each ear to coincidence-detector neurons in the brainstem. The CP indicates the mechanism underpinning the coincidence detector responses. A linear phase plot indicates a single, constant delay between the coincidence-detector inputs from the two ears. In more than half (54 of 90) of the neurons, the phase plot was not linear. We hypothesized that neurons with nonlinear phase plots received convergent input from brainstem coincidence detectors with different CDs. Presentation of a second tone with a fixed, unfavorable delay suppressed the response of one input, linearizing the phase plot and revealing other inputs to be relatively simple coincidence detectors. For some neurons with highly complex phase plots, the suppressor tone altered BP values, but did not resolve the nature of the inputs. For neurons with linear phase plots, the suppressor tone either completely abolished their responses or reduced their discharge rate with no change in BP. By selectively suppressing inputs with a second tone, we are able to reveal the nature of underlying binaural inputs to IC neurons, confirming the hypothesis that the complex phase plots of many IC neurons are a result of convergence from simple brainstem coincidence detectors.

  5. Coincidence and common fixed point of F-contractions via $CLR_{ST}$ property

    Directory of Open Access Journals (Sweden)

    Anita Tomar

    2016-03-01

    Full Text Available The aim of this paper is to establish the existence of coincidence and common fixed point of F-contractions via CLRST property. Our results generalize, extend and improve the results of Wardowski [D. Wardowski, Fixed points of a new type of contractive mappings in complete metric spaces, Fixed Point Theory and Applications (2012 2012:94, 6 pages, doi: 10.1186/1687-1812-2012-94], Batra et al. [Coincidence Point Theorem for a New Type of Contraction on Metric Spaces, Int. Journal of Math. Analysis, Vol. 8(27 2014, 1315-1320] and others existing in literature. Examples are also given in support of our results.

  6. Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

    International Nuclear Information System (INIS)

    Hu, Jianwei; Croft, Stephen; McElroy, Robert Dennis

    2017-01-01

    The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non- 3 He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235 U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

  7. Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-01-01

    The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non-3He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

  8. LIGO Triggered Search for Coincidence with High Energy Photon Survey Missions

    Science.gov (United States)

    Camp, Jordan

    2009-01-01

    LIGO is about to begin a new, higher sensitivity science run, where gravitational detection is plausible. A possible candidate for detection is a compact binary merger, which would also be likely to emit a high energy electromagnetic signal. Coincident observation of the gw signal from a compact merger with an x-ray or gamma-ray signal would add considerable weight to the claim for gw detection. In this talk I will consider the possibility of using LIGO triggers with time and sky position to perform a coincident analysis of EM signals from the RXTE, SWIFT, and FERMI missions.

  9. Study and development of a spectrometer with Compton suppression and gamma coincidence counting

    International Nuclear Information System (INIS)

    Masse, D.

    1990-10-01

    This paper presents the characteristics of a spectrometer consisting of a Ge detector surrounded by a NaI(T1) detector that can operate in Compton-suppression and gamma-gamma coincidence modes. The criteria that led to this measurement configuration are discussed and the spectrometer performances are shown for 60 Co and 137 Cs gamma-ray sources. The results for the measurement of 189 Ir (Compton suppression) and for the measurement of 101 Rh (gamma-gamma coincidence) in the presence of other radioisotopes are given. 83 Rb and 105 Ag isotopes are also measured with this spectrometer [fr

  10. A 15 channel 2- and 3-fold coincidence counting system for radioactivity standardization

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.; Raave, D.A.

    1986-01-01

    The 4π β-γ liquid scintillation coincidence counting system which is used at the National Accelerator Centre for standardizing radioisotopes, has been extended to allow for up to fifteen data points to be measured simultaneously by introducing a 15-fold coincidence unit and a 32-channel scaler into the system. A new control / data acquisition computer program has been written and its operation explained in detail. The advantages of the new system are discussed, and the activity of a 139 Ce source as measured by the new system and the old 3-fold system is compared

  11. n-Tupled Coincidence Point Theorems for Probabilistic ψ-Contractions in Menger Spaces

    Directory of Open Access Journals (Sweden)

    Penumarthy Parvateesam Murthy

    2016-01-01

    Full Text Available We introduced n-tupled coincidence point for a pair of maps T:Xn→X and A:X→X in Menger space. Utilizing the properties of the pseudometric and the triangular norm, we will establish n-tupled coincidence point theorems under weak compatibility as well as n-tupled fixed point theorems for hybrid probabilistic ψ-contractions with a gauge function. Our main results do not require the conditions of continuity and monotonicity of ψ. At the end of this paper, an example is given to support our main theorem.

  12. Neutron Multiplicity And Active Well Neutron Coincidence Verification Measurements Performed For March 2009 Semi-Annual DOE Inventory

    International Nuclear Information System (INIS)

    Dewberry, R.; Ayers, J.; Tietze, F.; Klapper, K.

    2010-01-01

    The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control and Accountability (MC and A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe) γ-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate γ-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC and A booking, and holdup measurements assays Site-wide. However none of the AD HpGe γ-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a γ-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC and A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.

  13. 4πβ(PS)–4πγ(GE) list-mode coincidence counter and its applications

    International Nuclear Information System (INIS)

    Yamada, T.; Kawada, Y.; Sato, Y.

    2016-01-01

    We developed a 4πβ–4πγ counter composed of a 4π plastic scintillation detector and a well-type Ge detector, employing digital coincidence counting and data storage in list-mode. In both of the β- and γ-channels, the amplified pulses from a linear amplifier feed the input channel of the digitizer directly via delay circuits. A signal from the peak-hold of each channel is fed to a sliding scale ADC (14 bits, 200 MHz clock) after peak detection and converted into 13 bit digital data, registered along with a time stamp and event channel allowing various data analysis to be implemented offline. When employing multiple gamma window settings, a weighted average of each apparent efficiency might be introduced to improve the efficiency functions. This idea was investigated along with reasonable estimates of the weighing factors, and activity measurements of 59 Fe using this system are presented. - Highlights: • A4πβ–4πγ system was developed, employing a well-type Ge-SSD and a plastic scintillator. • This system was employed to the measurement of 59 Fe with multiple γ-window settings. • An almost flat extrapolation curve could be obtained with appropriate weighting proecdures.

  14. A study on application of 18F-FDG coincidence imaging in diagnosis of cancer

    International Nuclear Information System (INIS)

    Liu Jianjun; Huang Gang; Shi Yiping; Yuan Jimin; Zhu Cuiying; Xu Qing

    2004-01-01

    To study the value of 18 F-FDG coincidence imaging in diagnosis of cancer, 101 patients who were suspicious of cancer were 18 F-FDG coincidence imaged before operation. Diagnoses of visual and semi-quantitative analysis were compared with the pathologic results after operation. The sensitivity and speciality of 18 F-FDG coincidence imaging were 84.61% and 78.26% in detecting cancer, while accuracy was 83.1%. For patients with a cancer of less than 2 cm, the sensitivity and speciality were 80% and 100%, accuracy was 82.35%. When standard of diagnosis was higher than 2.0 in T/N value, the sensitivity and speciality were 85.90% and 82.61%, while accuracy was 85.15%; when visual analysis was combined with semi-quantitative analysis, the sensitivity and speciality were 88.5% and 87.0%, while accuracy was 88.11%. In conclusion, it is of higher value to diagnose cancers with 18 F-FDG coincidence imaging and the accuracy of diagnosis can be improved by visual analysis combined with semi-quantitative analysis. (authors)

  15. Pre-coincidence brain activity predicts the perceptual outcome of streaming/bouncing motion display.

    Science.gov (United States)

    Zhao, Song; Wang, Yajie; Jia, Lina; Feng, Chengzhi; Liao, Yu; Feng, Wenfeng

    2017-08-18

    When two identical visual discs move toward each other on a two-dimensional visual display, they can be perceived as either "streaming through" or "bouncing off" each other after their coincidence. Previous studies have observed a strong bias toward the streaming percept. Additionally, the incidence of the bouncing percept in this ambiguous display could be increased by various factors, such as a brief sound at the moment of coincidence and a momentary pause of the two discs. The streaming/bouncing bistable motion phenomenon has been studied intensively since its discovery. However, little is known regarding the neural basis underling the perceptual ambiguity in the classic version of the streaming/bouncing motion display. The present study investigated the neural basis of the perception disambiguating underling the processing of the streaming/bouncing bistable motion display using event-related potential (ERP) recordings. Surprisingly, the amplitude of frontal central P2 (220-260 ms) that was elicited by the moving discs ~200 ms before the coincidence of the two discs was observed to be predictive of subsequent streaming or bouncing percept. A larger P2 amplitude was observed for streaming percept than the bouncing percept. These findings suggest that the streaming/bouncing bistable perception may have been disambiguated unconsciously ~200 ms before the coincidence of the two discs.

  16. Metformin and lactic acidosis : cause or coincidence? A review of case reports

    NARCIS (Netherlands)

    Stades, AME; Heikens, JT; Erkelens, DW; Holleman, F; Hoekstra, JBL

    Objective. Metformin has been associated with the serious side-effect lactic acidosis. However, it remains unclear whether the use of metformin was a cause or a coincidence in lactic acidosis. Design. A literature search of the Index Medicus (1959-66) and of the databases Embase, Medline, Medline

  17. Real Time Coincidence Detection Engine for High Count Rate Timestamp Based PET

    Science.gov (United States)

    Tetrault, M.-A.; Oliver, J. F.; Bergeron, M.; Lecomte, R.; Fontaine, R.

    2010-02-01

    Coincidence engines follow two main implementation flows: timestamp based systems and AND-gate based systems. The latter have been more widespread in recent years because of its lower cost and high efficiency. However, they are highly dependent on the selected electronic components, they have limited flexibility once assembled and they are customized to fit a specific scanner's geometry. Timestamp based systems are gathering more attention lately, especially with high channel count fully digital systems. These new systems must however cope with important singles count rates. One option is to record every detected event and postpone coincidence detection offline. For daily use systems, a real time engine is preferable because it dramatically reduces data volume and hence image preprocessing time and raw data management. This paper presents the timestamp based coincidence engine for the LabPET¿, a small animal PET scanner with up to 4608 individual readout avalanche photodiode channels. The engine can handle up to 100 million single events per second and has extensive flexibility because it resides in programmable logic devices. It can be adapted for any detector geometry or channel count, can be ported to newer, faster programmable devices and can have extra modules added to take advantage of scanner-specific features. Finally, the user can select between full processing mode for imaging protocols and minimum processing mode to study different approaches for coincidence detection with offline software.

  18. Increased coincidence detection for quantum versus pseudo-generated random numbers

    NARCIS (Netherlands)

    Boshoff, Lieze; Jolij, Jacob

    2015-01-01

    People often see meaning in stimuli that are typically considered meaningless. According to Von Lucadou’s idea of Generalized Quantum Teory (GQT), such perceived coincidences, or examples of synchronicity, may be the result of entanglement between a conscious observer and the physical world. Here we

  19. Calculation of coincidence summing corrections for a specific small soil sample geometry

    Energy Technology Data Exchange (ETDEWEB)

    Helmer, R.G.; Gehrke, R.J.

    1996-10-01

    Previously, a system was developed at the INEL for measuring the {gamma}-ray emitting nuclides in small soil samples for the purpose of environmental monitoring. These samples were counted close to a {approx}20% Ge detector and, therefore, it was necessary to take into account the coincidence summing that occurs for some nuclides. In order to improve the technical basis for the coincidence summing corrections, the authors have carried out a study of the variation in the coincidence summing probability with position within the sample volume. A Monte Carlo electron and photon transport code (CYLTRAN) was used to compute peak and total efficiencies for various photon energies from 30 to 2,000 keV at 30 points throughout the sample volume. The geometry for these calculations included the various components of the detector and source along with the shielding. The associated coincidence summing corrections were computed at these 30 positions in the sample volume and then averaged for the whole source. The influence of the soil and the detector shielding on the efficiencies was investigated.

  20. Study of the pygmy dipole resonance in Mo-94 using the (alpha, alpha ' gamma) coincidence technique

    NARCIS (Netherlands)

    Derya, V.; Endres, J.; Elvers, M.; Harakeh, M. N.; Pietralla, N.; Romig, C.; Savran, D.; Scheck, M.; Siebenhuehner, F.; Stoica, V. I.; Wortche, H. J.; Zilges, A.

    2013-01-01

    The (alpha, alpha' gamma) reaction at E-alpha = 136 MeV was used to study the electric dipole response in the open-shell vibrational nucleus Mo-94 below the neutron-separation threshold. The coincidence experiment has been performed at the Kernfysisch Versneller Instituut in Groningen, The

  1. COINCIDENCE MEASUREMENTS BETWEEN ELECTRONS FROM PROJECTILE AUTOIONIZATION AND TARGET IONS IN SPECIFIC CHARGE STATES

    NARCIS (Netherlands)

    POSTHUMUS, JH; LUKEY, P; MORGENSTERN, R

    1991-01-01

    For Ar9+ collisions on Ar we have - by means of a coincidence method - identified the number of primarily transferred electrons leading eventually to the emission of projectile Auger electrons at various energies. Auger cascades are found to play an important role: most of the high energy electrons

  2. Calibration and adjustment of the EGRET coincidence/time-of-flight system

    International Nuclear Information System (INIS)

    Hunter, S.D.

    1991-01-01

    The coincidence/time-of-flight system of the energetic gamma ray experiment telescope (EGRET) on NASA's Gamma Ray Observatory (GRO) consists of two layers of sixteen scintillator tiles. These tiles are paired into 96 coincidence telescopes. Valid coincidence and time-of-flight values (indicating downward moving particles) from one of these telescopes are two of the requirements for an EGRET event trigger. To maximize up-down discrimination, variations in the mean timing value of the telescopes must be minimized. The timing values of the 96 telescopes are not independent, hence they cannot be individually adjusted to calibrate the system. An iterative approach was devised to determine adjustments to the length of the photomultiplier signal cables. These adjustments were made directly in units of time using a time domain reflectometry technique, by timing the reflection of a fast pulse from the unterminated end of eable, and observing the charge in signal propagation time as the length of the cable was shortened. Two constant fraction discriminators, a time-to-amplitude converter and a pulse height analyzer were used for these measurements. Using this direct time measuring approach, the timing values for the 96 EGRET coincidence/time-of-flight telescopes were adjusted with an FWHM variation of less than 450 ps (± 1 TOF timing channel). (orig.)

  3. A simple and versatile data acquisition system for software coincidence and pulse-height discrimination in 4πβ-γ coincidence experiments.

    Science.gov (United States)

    Kawada, Y; Yamada, T; Unno, Y; Yunoki, A; Sato, Y; Hino, Y

    2012-09-01

    A simple but versatile data acquisition system for software coincidence experiments is described, in which any time stamping and live time controller are not provided. Signals from β- and γ-channels are fed to separately two fast ADCs (16 bits, 25 MHz clock maximum) via variable delay circuits and pulse-height stretchers, and also to pulse-height discriminators. The discriminating level was set to just above the electronic noise. Two ADCs were controlled with a common clock signal, and triggered simultaneously by the logic OR pulses from both discriminators. Paired digital signals for each sampling were sent to buffer memories connected to main PC with a FIFO (First-In, First-Out) pipe via USB. After data acquisition in list mode, various processing including pulse-height analyses was performed using MS-Excel (version 2007 and later). The usefulness of this system was demonstrated for 4πβ(PS)-4πγ coincidence measurements of (60)Co, (134)Cs and (152)Eu. Possibilities of other extended applications will be touched upon. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Detecting gravitational waves from inspiraling binaries with a network of detectors: Coherent versus coincident strategies

    International Nuclear Information System (INIS)

    Mukhopadhyay, Himan; Dhurandhar, Sanjeev; Sago, Norichika; Tagoshi, Hideyuki; Takahashi, Hirotaka; Kanda, Nobuyuki

    2006-01-01

    We compare two strategies of multidetector detection of compact binary inspiral signals, namely, the coincidence and the coherent. For simplicity we consider here two identical detectors having the same power spectral density of noise, that of initial LIGO, located in the same place and having the same orientation. We consider the cases of independent noise as well as that of correlated noise. The coincident strategy involves separately making two candidate event lists, one for each detector, and from these choosing those pairs of events from the two lists which lie within a suitable parameter window, which then are called coincidence detections. The coherent strategy on the other hand involves combining the data phase coherently, so as to obtain a single network statistic which is then compared with a single threshold. Here we attempt to shed light on the question as to which strategy is better. We compare the performances of the two methods by plotting the receiver operating characteristics (ROC) for the two strategies. Several of the results are obtained analytically in order to gain insight. Further we perform numerical simulations in order to determine certain parameters in the analytic formulae and thus obtain the final complete results. We consider here several cases from the relatively simple to the astrophysically more relevant in order to establish our results. The bottom line is that the coherent strategy although more computationally expensive in general than the coincidence strategy, is superior to the coincidence strategy--considerably less false dismissal probability for the same false alarm probability in the viable false alarm regime

  5. Parenting Multiples

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Parenting Multiples KidsHealth / For Parents / Parenting Multiples What's in ... your ability to take care of your babies. Parenting Issues With Multiples It may be difficult to ...

  6. The spallation in reverse kinematics: what for a coincidence measurement?; La spallation en cinematique inverse: pourquoi faire une mesure en coincidence?

    Energy Technology Data Exchange (ETDEWEB)

    Ducret, J.E

    2006-07-15

    The Spaladin installation has been designed to study spallation reactions in reverse kinematics. Furthermore, the heavy and light fragments are detected by coincidence which allows us to get an instantaneous picture of the reaction at a level of accuracy better than that obtained through inclusive measurement. The first part is dedicated to the theoretical description of the different mechanisms involved in the spallation reactions. In the second part we describe the Spaladin installation and report some results on the reaction: Fe{sup 56} + p at an energy of 1 GeV/nucleon. In the third part we expose the performance of the installation through its simulation with the Geant-IV model. We present a study about the sensitivity of the Spaladin installation to theoretical predictions. The fourth part is dedicated to the future experiments that will be performed with the Spaladin installation. (A.C.)

  7. X-ray spectral line coincidences between fluorine VIII (and IX) and transition metal lines

    International Nuclear Information System (INIS)

    Charatis, G.; Rockett, P.D.; Burkhalter, P.G.

    1983-01-01

    X-ray spectroscopy was performed in the 12 to 15 A region, recording L-shell lines from selected laser-irradiated transition metals. Line coincidences and near coincidences were identified between Fe, Cr, Mn, and Ni L-spectra, and F VIII and F IX K-shell lines. Wavelengths were determined to accuracies of 1 to 3 mA and will be utilized in selecting potential pumping candidates in future x-ray lasing schemes. High-resolution x-ray spectra were collected under controlled illumination and target conditions using 1.05 μm and 0.527 μm laser excitation with the KMS CHROMA laser

  8. Calculation of “LS-curves” for coincidence summing corrections in gamma ray spectrometry

    Science.gov (United States)

    Vidmar, Tim; Korun, Matjaž

    2006-01-01

    When coincidence summing correction factors for extended samples are calculated in gamma-ray spectrometry from full-energy-peak and total efficiencies, their variation over the sample volume needs to be considered. In other words, the correction factors cannot be computed as if the sample were a point source. A method developed by Blaauw and Gelsema takes the variation of the efficiencies over the sample volume into account. It introduces the so-called LS-curve in the calibration procedure and only requires the preparation of a single standard for each sample geometry. We propose to replace the standard preparation by calculation and we show that the LS-curves resulting from our method yield coincidence summing correction factors that are consistent with the LS values obtained from experimental data.

  9. Gamma-X-ray coincidence Moessbauer spectroscopic study of the aftereffects in sulfate hydrates

    International Nuclear Information System (INIS)

    Kobayashi, T.; Makita, T.; Fukumura, K.

    1990-01-01

    The anomalous charge states formed after the electron capture decay of 57 Co in FeSO 4 .H 2 O and FeSO 4 .7H 2 O are investigated using the conventional Moessbauer emission spectroscopy and a gamma-X ray coincidence method. This method is based on the idea that a Moessbauer spectrum observed with the coincidence technique only when K-X rays are emitted is reflected by isolated events with a reduced influence of the Auger-electron self-irradiation. The formation of the anomalous electronic and structural configuration is attributed to the self-radiolysis of the H 2 O and SO 4 2- ligands in the nearest and the second nearest coordination shells around the decaying atom. (orig.)

  10. Performance evaluation of BGO block detectors used in positron emission tomography and a coincidence system

    International Nuclear Information System (INIS)

    Kim, J. H.; Choi, Y.; Lim, K. C.; Lee, M. Y.; Woo, S. K.; Lee, K. H.; Kim, S. E.; Choi, Y. S.; Kim, B. T.

    1999-01-01

    We investigated the basic performances of the BGO block detectors, which is used in the GE Advance positron emission tomography. The block detector is composed of 36 small BGO crystals coupled to two 2-channel photomultiplier tubes. In this study, we measured the crystal map and the intrinsic energy resolution of the detector. The coincidence signals between the detectors were also obtained using F-18. The intrinsic energy resolution of the block detector was 69% FWHM at 140 keV and 33% FWHM at 511 keV. High quality crystal map and the coincidence signals between the detectors were successfully obtained. The timing resolution of the detectors are being measured. The results of this study demonstrate the feasibility of developing high performance positron emission tomography

  11. A processing circuit for overlapped pulse signals for a thermal neutron coincidence counter

    International Nuclear Information System (INIS)

    Lee, Chul-Yong; Lee, Tae-hoon; Kim, Ho-dong

    2009-01-01

    We have developed a processing circuit for overlapped pulse signals. The overlapped pulse signals are generated when the pulse signals of a He-3 detector, by using a neutron coincidence counter, are connected to shift register coincidence electronics by an OR gate device. The developed circuit detects the overlapped pulse signals from among four input signals and produces new 50 ns pulse wide signals. We considered a case where two pulse signals are simultaneously overlapped among four signals. This circuit was tested with an ACP safeguards neutron counter (ASNC) for an advanced spent fuel conditioning process (ACP) and a 252 Cf neutron source at high rates. The loss rate of the output signal was reduced by 1.27% for singles and 4.75% for doubles when compared with the OR gate device. Also the variation for the triples was much bigger.

  12. A processing circuit for overlapped pulse signals for a thermal neutron coincidence counter.

    Science.gov (United States)

    Lee, Chul-Yong; Lee, Tae-Hoon; Kim, Ho-Dong

    2009-11-01

    We have developed a processing circuit for overlapped pulse signals. The overlapped pulse signals are generated when the pulse signals of a He-3 detector, by using a neutron coincidence counter, are connected to shift register coincidence electronics by an OR gate device. The developed circuit detects the overlapped pulse signals from among four input signals and produces new 50 ns pulse wide signals. We considered a case where two pulse signals are simultaneously overlapped among four signals. This circuit was tested with an ACP safeguards neutron counter (ASNC) for an advanced spent fuel conditioning process (ACP) and a (252)Cf neutron source at high rates. The loss rate of the output signal was reduced by 1.27% for singles and 4.75% for doubles when compared with the OR gate device. Also the variation for the triples was much bigger.

  13. Studies of weak capture-gamma-ray resonances via coincidence techniques

    CERN Document Server

    Rowland, C; Champagne, A E; Dummer, A K; Fitzgerald, R; Harley, E C T; Mosher, J; Runkle, R

    2002-01-01

    A method for measuring weak capture-gamma-ray resonances via gamma gamma-coincidence counting techniques is described. The coincidence apparatus consisted of a large-volume germanium detector and an annular NaI(Tl) crystal. The setup was tested by measuring the weak E sub R =227 keV resonance in sup 2 sup 6 Mg(p,gamma) sup 2 sup 7 Al. Absolute germanium and NaI(Tl) counting efficiencies for a range of gamma-ray energies and for different detector-target geometries are presented. Studies of the gamma-ray background in our spectra are described. Compared to previous work, our method improves the detection sensitivity for weak capture-gamma-ray resonances by a factor of approx 100. The usefulness of the present technique for investigations of interest to nuclear astrophysics is discussed.

  14. SPADnet: Embedded coincidence in a smart sensor network for PET applications

    Energy Technology Data Exchange (ETDEWEB)

    Bruschini, C., E-mail: claudio.bruschini@epfl.ch [Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Charbon, E. [Delft University of Technology, Delft (Netherlands); Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Veerappan, C. [Delft University of Technology, Delft (Netherlands); Braga, L.H.C.; Massari, N.; Perenzoni, M.; Gasparini, L.; Stoppa, D. [Fondazione Bruno Kessler (FBK), Trento (Italy); Walker, R.; Erdogan, A.; Henderson, R.K. [University of Edinburgh, Edinburgh (United Kingdom); East, S.; Grant, L. [STMicroelectronics (R and D) Ltd, Edinburgh (United Kingdom); Jatekos, B.; Ujhelyi, F.; Erdei, G.; Lörincz, E. [Budapest University of Technology and Economics (BME), Budapest (Hungary); André, L.; Maingault, L.; Reboud, V. [CEA-LETI, Grenoble (France); and others

    2014-01-11

    In this paper we illustrate the core technologies at the basis of the European SPADnet project ( (www.spadnet.eu)), and present the corresponding first results. SPADnet is aimed at a new generation of MRI-compatible, scalable large area image sensors, based on CMOS technology, that are networked to perform gamma-ray detection and coincidence to be used primarily in (Time-of-Flight) Positron Emission Tomography (PET). The project innovates in several areas of PET systems, from optical coupling to single-photon sensor architectures, from intelligent ring networks to reconstruction algorithms. In addition, SPADnet introduced the first computational model enabling study of the full chain from gamma photons to network coincidence detection through scintillation events, optical coupling, etc.

  15. SPADnet: Embedded coincidence in a smart sensor network for PET applications

    International Nuclear Information System (INIS)

    Bruschini, C.; Charbon, E.; Veerappan, C.; Braga, L.H.C.; Massari, N.; Perenzoni, M.; Gasparini, L.; Stoppa, D.; Walker, R.; Erdogan, A.; Henderson, R.K.; East, S.; Grant, L.; Jatekos, B.; Ujhelyi, F.; Erdei, G.; Lörincz, E.; André, L.; Maingault, L.; Reboud, V.

    2014-01-01

    In this paper we illustrate the core technologies at the basis of the European SPADnet project ( (www.spadnet.eu)), and present the corresponding first results. SPADnet is aimed at a new generation of MRI-compatible, scalable large area image sensors, based on CMOS technology, that are networked to perform gamma-ray detection and coincidence to be used primarily in (Time-of-Flight) Positron Emission Tomography (PET). The project innovates in several areas of PET systems, from optical coupling to single-photon sensor architectures, from intelligent ring networks to reconstruction algorithms. In addition, SPADnet introduced the first computational model enabling study of the full chain from gamma photons to network coincidence detection through scintillation events, optical coupling, etc

  16. Detection of coincident radiations in a single transducer by pulse shape analysis

    Science.gov (United States)

    Warburton, William K [Menlo Park, CA

    2008-03-11

    Pulse shape analysis determines if two radiations are in coincidence. A transducer is provided that, when it absorbs the first radiation produces an output pulse that is characterized by a shorter time constant and whose area is nominally proportional to the energy of the absorbed first radiation and, when it absorbs the second radiation produces an output pulse that is characterized by a longer time constant and whose area is nominally proportional to the energy of the absorbed second radiation. When radiation is absorbed, the output pulse is detected and two integrals are formed, the first over a time period representative of the first time constant and the second over a time period representative of the second time constant. The values of the two integrals are examined to determine whether the first radiation, the second radiation, or both were absorbed in the transducer, the latter condition defining a coincident event.

  17. Equivalence of computer codes for calculation of coincidence summing correction factors

    International Nuclear Information System (INIS)

    Vidmar, T.; Capogni, M.; Hult, M.; Hurtado, S.; Kastlander, J.; Lutter, G.; Lépy, M.-C.; Martinkovič, J.; Ramebäck, H.; Sima, O.; Tzika, F.; Vidmar, G.

    2014-01-01

    The aim of the study was to check for equivalence of computer codes that can perform calculations of true coincidence summing correction factors. All calculations were performed for a set of well-defined detector and sample parameters, without any reference to empirical data. For a p-type detector model the application of different codes resulted in satisfactory agreement in the calculated correction factors. For high-efficiency geometries in combination with an n-type detector and a radionuclide emitting abundant X-rays the results were scattered. - Highlights: • Measured and calculated true coincidence corrections differ in recent study. • We checked for equivalence of computer codes that can perform such calculations. • Codes compared with each other for a set of well-defined detector and sample models. • Satisfactory agreement between the codes for a p-type detector model. • Large differences for an n-type detector model and X-ray emitting radionuclides

  18. Use of γ-γ coincidence spectrometry in the geochemical study of diamictites from South Africa

    International Nuclear Information System (INIS)

    Huber, H.; Koeberl, Ch.; McDonald, I.; Reimold, W.U.

    2000-01-01

    γ-γ coincidence spectrometry was used to investigate the possible presence of a meteoritical component in 27 samples of South African diamictites. Recently, several studies have suggested that some tillites/diamictites may represent impact breccias, but a petrographical study by our group found no evidence for the presence of impact-characteristic shocked minerals. The siderophile elements, such as Cr, Co, Ni, and, especially, the platinum group elements, have high abundances in meteorites, but low abundances in terrestrial crustal rocks. The Ir content of the diamictites was measured with the new iridium coincidence spectrometer (ICS) at the University of Vienna, with detection limits of around 0.02 ppb. No enrichments in the contents of Ir and other siderophile elements compared to average crustal concentrations were found; thus, no unequivocal evidence for an impact origin of these diamictites of the South African Dwyka Group can be documented. (author)

  19. Performances of the Coincidence Matrix ASIC of the ATLAS Barrel Level-1 Muon Trigger

    CERN Document Server

    Pastore, F; Vari, R; Veneziano, S

    2005-01-01

    The ATLAS Barrel Level-1 muon trigger handles data coming from the Resistive Plate Chamber detectors, structured in three concentric layers inside the air-core barrel toroid. The trigger classifies muons within different programmable transverse momentum thresholds, and tags the identified tracks with the corresponding bunch crossing number. The algorithm looks for hit coincidences within different detector layers inside the programmed geometrical road which defines the transverse momentum cut. The Coincidence Matrix ASIC implements the trigger algorithm and the readout of the RPC detector, processing hit signals coming from up to four detector layers. It finds muon track candidates and generates the output trigger patterns with a latency of a few 25 ns bunch crossing periods, and produces and time tags the readout hit patterns. Due to the different performance needs and limitations in the maximum power dissipation and technology, the CMA input pipeline and trigger logic and the time interpolator run at the wo...

  20. Coincidence system for standardization of radionuclides using a 4 pi plastic scintillator detector

    CERN Document Server

    Baccarelli, A M; Koskinas, M F

    2003-01-01

    A coincidence system using a plastic scintillator detector in 4 pi geometry has been developed and applied for the standardization of radionuclides. The scintillator shape and dimensions have been optimized for maximum charge particle detection efficiency, while keeping background low and a nearly constant gamma-ray efficiency for different points from the radioactive source. The gamma-ray events were measured with a NaI(Tl) scintillation counter. The electronic system for processing pulses consisted of logic gates and delay modules feeding a time-to-amplitude converter with output to a multichannel analyzer. The alpha detection efficiency measured with sup 2 sup 4 sup 1 Am was around 95% and the beta detection efficiency for sup 6 sup 0 Co was around 67%. Activity measurements of sup 2 sup 4 sup 1 Am and sup 6 sup 0 Co were performed and the results showed good agreement when compared with a conventional coincidence system employing a 4 pi proportional counter.

  1. New tools for analyzing the Mexican economy: indexes of coincident and leading economic indicators

    OpenAIRE

    Keith R. Phillips; Lucinda Vargas; Victor Zarnowitz

    1996-01-01

    New composite indexes presented in this article could prove useful in analyzing and forecasting the Mexican economy. Keith Phillips, Lucinda Vargas, and Victor Zarnowitz present composite indexes of leading and coincident indexes for Mexico. In constructing the indexes, the economists use an approach similar to that developed by the National Bureau of Economic Research to create the composite indexes of U.S. economic activity. The authors classify peaks and troughs in the Mexican business cyc...

  2. Surgical guidance system using hand-held probe with accompanying positron coincidence detector

    Energy Technology Data Exchange (ETDEWEB)

    Majewski, Stanislaw; Weisenberger, Andrew G.

    2017-10-10

    A surgical guidance system offering different levels of imaging capability while maintaining the same hand-held convenient small size of light-weight intra-operative probes. The surgical guidance system includes a second detector, typically an imager, located behind the area of surgical interest to form a coincidence guidance system with the hand-held probe. This approach is focused on the detection of positron emitting biomarkers with gamma rays accompanying positron emissions from the radiolabeled nuclei.

  3. Coincidences and Estimation of Entropies of Random Variables with Large Cardinalities

    Directory of Open Access Journals (Sweden)

    Ilya Nemenman

    2011-12-01

    Full Text Available We perform an asymptotic analysis of the NSB estimator of entropy of a discrete random variable. The analysis illuminates the dependence of the estimates on the number of coincidences in the sample and shows that the estimator has a well defined limit for a large cardinality of the studied variable. This allows estimation of entropy with no a priori assumptions about the cardinality. Software implementation of the algorithm is available.

  4. Double Photon Emission Coincidence Imaging using GAGG-SiPM pixel detectors

    Science.gov (United States)

    Shimazoe, K.; Uenomachi, M.; Mizumachi, Y.; Takahashi, H.; Masao, Y.; Shoji, Y.; Kamada, K.; Yoshikawa, A.

    2017-12-01

    Single photon emission computed tomography(SPECT) is a useful medical imaging modality using single photon detection from radioactive tracers, such as 99Tc and 111In, however further development of increasing the contrast in the image is still under investigation. A novel method (Double Photon Emission CT / DPECT) using a coincidence detection of two cascade gamma-rays from 111In is proposed and characterized in this study. 111In, which is well-known and commonly used as a SPECT tracer, emits two cascade photons of 171 keV and 245 keV with a short delay of approximately 85 ns. The coincidence detection of two gamma-rays theoretically determines the position in a single point compared with a line in single photon detection and increases the signal to noise ratio drastically. A fabricated pixel detector for this purpose consists of 8 × 8 array of high-resolution type 1.5 mm thickness Ce:GAGG (3.9% @ 662 keV, 6.63g/cm3, C&A Co. Ce:Gd3Ga2.7Al2.3O12 2.5 × 2.5 × 1.5 mm3) crystals coupled a 3 mm pixel SiPM array (Hamamatsu MPPC S13361-2050NS-08). The signal from each pixel is processed and readout using time over threshold (TOT) based parallel processing circuit to extract the energy and timing information. The coincidence was detected by FPGA with the frequency of 400 MHz. Two pixel detectors coupled to parallel-hole collimators are located at the degree of 90 to determine the position and coincidence events (time window =1 μs) are detected and used for making back-projection image. The basic principle of DPECT is characterized including the detection efficiency and timing resolution.

  5. A coincidence point result in Menger spaces using a control function

    Energy Technology Data Exchange (ETDEWEB)

    Choudhury, Binayak S. [Department of Mathematics, Bengal Engineering and Science University, P.O. B. Garden, Shibpur, Howrah, West Bengal 711103 (India); Das, Krishnapada [Department of Mathematics, Bengal Engineering and Science University, P.O. B. Garden, Shibpur, Howrah, West Bengal 711103 (India)], E-mail: kestapm@yahoo.co.in

    2009-12-15

    In the present work we prove a coincidence point theorem in Menger spaces with a t-norm T which satisfies the condition sup{l_brace}T(t,t):t<1{r_brace}=1. As a corollary of our theorem we obtain some existing results in metric spaces and probabilistic metric spaces. Particularly our result implies a probabilistic generalization of Banach contraction mapping theorem. We also support our result by an example.

  6. Field tests and evaluations of the IAEA Active-Well Coincidence Counter

    International Nuclear Information System (INIS)

    Krick, M.S.; Rinard, P.M.

    1982-12-01

    This report summarizes and evaluates field tests of the Active Well Coincidence Counter (AWCC) at Winfrith and Dounreay, United Kingdom. The applicability of the AWCC for assaying the uranium content of a wide variety of materials was demonstrated and calibration curves were generated. The AWCC was used in three modes (fast, thermal, and passive) while assaying powders, pellets, cartridges, plates, assorted residues, and materials-testing-reactor fuel assemblies

  7. A Contractive Metric for Systems of Conservation Laws with Coinciding Shock and Rarefaction Curves

    Science.gov (United States)

    Bressan, A.

    We introduce two algorithms for the construction of weak, entropy-admissible solutions to a class of systems of conservation laws with coinciding shock and rarefaction curves. Global existence, uniqueness, and continuous dependence are proved for all solutions obtained by our constructive procedure. The generated semigroup is contractive with respect to a Riemann-type metric, defined in terms of Glimm's wave interaction functional, equivalent to the usual L1 distance.

  8. High-level neutron coincidence counter (HLNCC): users' manual

    Energy Technology Data Exchange (ETDEWEB)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective /sup 240/Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications.

  9. Determination of U-chain concentration in NaI(Tl) scintillator by delayed coincidence method

    CERN Document Server

    Umehara, S; Koori, N; Kudomi, N; Kume, K; Kuramoto, H; Nakayama, S; Shimojo, T; Takahisa, K; Tsubakida, R; Tsujimoto, Y; Yoshida, S

    2002-01-01

    We have accurately determined U-chain concentration in a detector by means of the beta-alpha delayed coincidence method. This method can measure the radioactivity of the order of 10 sup - sup 7 Bq/kg. It corresponds to the concentration of the order of 0.01 ppt under the assumption that the U-chain is in the secular radioactive equilibrium, by a signal-to-noise ratio of one to one.

  10. Hippocampal sharp wave bursts coincide with neocortical “up-state” transitions

    OpenAIRE

    Battaglia, Francesco P.; Sutherland, Gary R.; McNaughton, Bruce L.

    2004-01-01

    The sleeping neocortex shows nested oscillatory activity in different frequency ranges, characterized by fluctuations between “up-states” and “down-states.” High-density neuronal ensemble recordings in rats now reveal the interaction between synchronized activity in the hippocampus and neocortex: Electroencephalographic sharp waves in the hippocampus were more probable during down-states than during up-states, and tended to coincide with transitions from down-states to up-states. The form of ...

  11. 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle detection

    Science.gov (United States)

    Vignetti, M. M.; Calmon, F.; Pittet, P.; Pares, G.; Cellier, R.; Quiquerez, L.; Chaves de Albuquerque, T.; Bechetoille, E.; Testa, E.; Lopez, J.-P.; Dauvergne, D.; Savoy-Navarro, A.

    2018-02-01

    Single-Photon Avalanche Diodes (SPADs) are p-n junctions operated in Geiger Mode by applying a reverse bias above the breakdown voltage. SPADs have the advantage of featuring single photon sensitivity with timing resolution in the picoseconds range. Nevertheless, their relatively high Dark Count Rate (DCR) is a major issue for charged particle detection, especially when it is much higher than the incoming particle rate. To tackle this issue, we have developed a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD). This novel device implements two vertically aligned SPADs featuring on-chip electronics for the detection of coincident avalanche events occurring on both SPADs. Such a coincidence detection mode allows an efficient discrimination of events related to an incoming charged particle (producing a quasi-simultaneous activation of both SPADs) from dark counts occurring independently on each SPAD. A 3D-SiCAD detector prototype has been fabricated in CMOS technology adopting a 3D flip-chip integration technique, and the main results of its characterization are reported in this work. The particle detection efficiency and noise rejection capability for this novel device have been evaluated by means of a β- strontium-90 radioactive source. Moreover the impact of the main operating parameters (i.e. the hold-off time, the coincidence window duration, the SPAD excess bias voltage) over the particle detection efficiency has been studied. Measurements have been performed with different β- particles rates and show that a 3D-SiCAD device outperforms single SPAD detectors: the former is indeed capable to detect particle rates much lower than the individual DCR observed in a single SPAD-based detectors (i.e. 2 to 3 orders of magnitudes lower).

  12. The effect of acute caffeine ingestion on coincidence anticipation timing in younger and older adults.

    Science.gov (United States)

    Duncan, Michael J; Tallis, Jason; Wright, Sheila Leddington; Eyre, Emma L J; Bryant, Elizabeth; Langdon, Dominic

    2014-09-01

    This study compared the effect of acute caffeine ingestion on coincidence timing accuracy in younger and older adults. Thirteen young (aged 18-25 years, age: 20 ± 2 years, 7 females, 5 males) and 13 older (aged 61-77 years, age: 68 ± 6 years, 9 females, 3 males) adults, all who were habitual moderate caffeine consumers undertook measures of coincident anticipation timing performance pre- and post-acute caffeine (3 mg/kg) or placebo ingestion administered in a double blind, randomized fashion. Results indicated significant pre-to-post X substance (caffeine vs. placebo) interactions for absolute (P = 0.02, Pη(2) = 0.204) and variable error (P = 0.015, Pη(2) = 0.221). In both cases, error (absolute or variable) improved pre-to-post ingestion in the caffeine condition but not in the placebo condition. There were no significant differences due to age (younger vs. older adults, P > 0.05) in any of the analyses. The results of this study suggest that acute caffeine ingestion positively influence coincidence anticipation timing performance in both younger and older adults, who are moderate habitual caffeine consumers. Such effects might therefore be useful for older adults in enhancing ability to undertake cognitive-perceptual tasks which involve interceptive actions.

  13. Positron Annihilation in Carbon Nanotubes Studied by Coincidence Doppler Broadening Spectroscopy

    Science.gov (United States)

    Murakami, H.; Sato, K.; Kanazawa, I.; Sano, M.

    2008-05-01

    In order to assign the sites of positron annihilation, coincidence Doppler broadening spectra were measured for a highly oriented pyrolytic graphite crystal, graphite powder, multi-walled carbon nanotubes (MNTs) and cup-stacked carbon nanotubes (CNTs). The spectrum for graphite powder normalized to that for highly oriented pyrolytic graphite (HOPG) is almost flat in the momentum region from 7×10-3 to 13×10-3 mec, having a ratio close to unity. The flat spectrum demonstrates that positrons injected into graphite powder annihilate in the interlayer spaces of piled graphite sheets, in the same manner as positrons in highly oriented pyrolytic graphite annihilate in the bulk. The coincidence Doppler broadening spectra for MNTs and CNTs are quite different from that for highly oriented pyrolytic graphite, which indicates that positrons injected into MNTs and CYTs annihilate not in the bulk, but on surface. The positron lifetime spectrum for multi-walled carbon nanotubes is analyzed in terms of a single component due to surface-trapped positrons, while that for CNTs is decomposed into three components attributable to para-positronium surface-trapped positrons and ortho-positronium. The difference between the coincidence Doppler broadening spectrum for CNTs and that for MNTs is explained in terms of positron annihilation on zigzag surfaces of CNTs which are composed of both graphite-sheet and graphite-edge planes.

  14. New approach to calculate the true-coincidence effect of HpGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Alnour, I. A., E-mail: aaibrahim3@live.utm.my, E-mail: ibrahim.elnour@yahoo.com [Department of Physics, Faculty of Pure and Applied Science, International University of Africa, 12223 Khartoum (Sudan); Wagiran, H. [Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Skudai,Johor (Malaysia); Ibrahim, N. [Faculty of Defence Science and Technology, National Defence University of Malaysia, Kem Sungai Besi, 57000 Kuala Lumpur (Malaysia); Hamzah, S.; Elias, M. S. [Malaysia Nuclear Agency (MNA), Bangi, 43000 Kajang, Selangor D.E. (Malaysia); Siong, W. B. [Chemistry Department, Faculty of Resource Science & Technology, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Sarawak (Malaysia)

    2016-01-22

    The corrections for true-coincidence effects in HpGe detector are important, especially at low source-to-detector distances. This work established an approach to calculate the true-coincidence effects experimentally for HpGe detectors of type Canberra GC3018 and Ortec GEM25-76-XLB-C, which are in operation at neutron activation analysis lab in Malaysian Nuclear Agency (NM). The correction for true-coincidence effects was performed close to detector at distances 2 and 5 cm using {sup 57}Co, {sup 60}Co, {sup 133}Ba and {sup 137}Cs as standard point sources. The correction factors were ranged between 0.93-1.10 at 2 cm and 0.97-1.00 at 5 cm for Canberra HpGe detector; whereas for Ortec HpGe detector ranged between 0.92-1.13 and 0.95-100 at 2 and 5 cm respectively. The change in efficiency calibration curve of the detector at 2 and 5 cm after correction was found to be less than 1%. Moreover, the polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points.

  15. Observation of relaxation on time scale of core hole decay by coincidence photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2007-01-01

    It is shown by a many-body theory that when the relaxation time of a metastable core hole state(s) to the most stable one is comparable to or shorter than core hole decay time of the former state(s), a comparison between the singles (noncoincidence) photoelectron spectroscopy (PES) spectrum and the coincidence one provides a direct evidence of the relaxation. In principle the variation with photoelectron kinetic energy of relaxation (or charge transfer (CT)) time can be determined. By singles measurement the correlation of a photoelectron generated by creation of the metastable states not only with an Auger electron generated by annihilation of the same core hole state but also with an Auger electron generated by annihilation of the stable state via relaxation of the metastable state, is completely lost, unless only the metastable state is observed by PES, whereas the correlation often manifests directly in the coincidence spectra. Thus, compared to the coincidence spectroscopy the singles one is often much less capable of elucidating the competition between relaxation and core hole decay of a metastable state. Such examples are discussed

  16. Frequencies of mutagen-induced coincident mitotic recombination at unlinked loci in Saccharomyces cerevisiae

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Kathryn M. [Department of Biology, College of the Holy Cross, One College Street, Worcester, MA 01610-2395 (United States); Hoffmann, George R. [Department of Biology, College of the Holy Cross, One College Street, Worcester, MA 01610-2395 (United States)]. E-mail: ghoffmann@holycross.edu

    2007-03-01

    Frequencies of coincident genetic events were measured in strain D7 of Saccharomyces cerevisiae. This diploid strain permits the detection of mitotic gene conversion involving the trp5-12 and trp5-27 alleles, mitotic crossing-over and gene conversion leading to the expression of the ade2-40 and ade2-119 alleles as red and pink colonies, and reversion of the ilv1-92 allele. The three genes are on different chromosomes, and one might expect that coincident (simultaneous) genetic alterations at two loci would occur at frequencies predicted by those of the single alterations acting as independent events. Contrary to this expectation, we observed that ade2 recombinants induced by bleomycin, {beta}-propiolactone, and ultraviolet radiation occur more frequently among trp5 convertants than among total colonies. This excess among trp5 recombinants indicates that double recombinants are more common than expected for independent events. No similar enrichment was found among Ilv{sup +} revertants. The possibility of an artifact in which haploid yeasts that mimic mitotic recombinants are generated by a low frequency of cryptic meiosis has been excluded. Several hypotheses that can explain the elevated incidence of coincident mitotic recombination have been evaluated, but the cause remains uncertain. Most evidence suggests that the excess is ascribable to a subset of the population being in a recombination-prone state.

  17. A new double imaging velocity focusing coincidence experiment: i{sup 2}PEPICO

    Energy Technology Data Exchange (ETDEWEB)

    Bodi, Andras; Hemberger, Patrick; Gerber, Thomas [Paul Scherrer Institut, Villigen 5232 (Switzerland); Sztaray, Balint [Department of Chemistry, University of the Pacific, Stockton, California 95211 (United States)

    2012-08-15

    The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary double imaging setup (i{sup 2}PEPICO) has been built. Volatile samples can be introduced at room temperature or in a molecular beam, a pyrolysis source allows for radical production, and non-volatile solids can be evaporated in a heated cell. Monochromatic VUV radiation ionizes the sample and both photoelectrons and photoions are velocity map imaged onto two fast position sensitive detectors and detected in delayed coincidence. High intensity synchrotron radiation leads to ionization rates above 10{sup 5} s{sup -1}. New data acquisition and processing approaches are discussed for recording coincidence processes at high rates. The setup is capable of resolving pulsed molecular beam profiles and the synchrotron time structure temporally. The latter is shown by photoelectron autocorrelation, which displays both the 1.04 MHz ring clock frequency as well as resolving the micro-pulses with a separation of 2 ns. Kinetic energy release analysis on the dissociative photoionization of CF{sub 4} indicates a dissociation mechanism change in the Franck-Condon allowed energy range of the first ion state.

  18. Frequencies of mutagen-induced coincident mitotic recombination at unlinked loci in Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Freeman, Kathryn M.; Hoffmann, George R.

    2007-01-01

    Frequencies of coincident genetic events were measured in strain D7 of Saccharomyces cerevisiae. This diploid strain permits the detection of mitotic gene conversion involving the trp5-12 and trp5-27 alleles, mitotic crossing-over and gene conversion leading to the expression of the ade2-40 and ade2-119 alleles as red and pink colonies, and reversion of the ilv1-92 allele. The three genes are on different chromosomes, and one might expect that coincident (simultaneous) genetic alterations at two loci would occur at frequencies predicted by those of the single alterations acting as independent events. Contrary to this expectation, we observed that ade2 recombinants induced by bleomycin, β-propiolactone, and ultraviolet radiation occur more frequently among trp5 convertants than among total colonies. This excess among trp5 recombinants indicates that double recombinants are more common than expected for independent events. No similar enrichment was found among Ilv + revertants. The possibility of an artifact in which haploid yeasts that mimic mitotic recombinants are generated by a low frequency of cryptic meiosis has been excluded. Several hypotheses that can explain the elevated incidence of coincident mitotic recombination have been evaluated, but the cause remains uncertain. Most evidence suggests that the excess is ascribable to a subset of the population being in a recombination-prone state

  19. Coincidence Point, Best Approximation, and Best Proximity Theorems for Condensing Set-Valued Maps in Hyperconvex Metric Spaces

    Directory of Open Access Journals (Sweden)

    Farajzadeh AP

    2008-01-01

    Full Text Available Abstract In hyperconvex metric spaces, we first present a coincidence point theorem for condensing set-valued self-maps. Then we consider the best approximation problem and the best proximity problem for set-valued mappings that are condensing. As an application, we derive a coincidence point theorem for nonself-condensing set-valued maps.

  20. Search for transient gravitational waves in coincidence with short-duration radio transients during 2007-2013

    NARCIS (Netherlands)

    Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Phythian-Adams, A.T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Aggarwal, N.T.; Aguiar, O. D.; Aiello, L.; Ain, A.; Ajith, P.; Allen, B.; Allocca, A.; Altin, P. A.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Babak, S.; Bacon, P.; Bader, M. K. M.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, R.D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Baune, C.; Bavigadda, V.; Bazzan, M.; Behnke, B.; Bejger, M.; Bell, A. S.; Bell, C. J.; Berger, B. K.; Bergman, J.; Bergmann, G.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Birch, M.J.; Birney, R.; Biscans, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, A.L.S.; Bock, O.; Bodiya, T. P.; Boer, M.; Bogaert, J.G.; Bogan, C.; Bohe, A.; Bojtos, P.; Bond, T.C; Bondu, F.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Brooks, A. F.; Brown, A.D.; Brown, D.; Brown, N. M.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Calderon Bustillo, J.; Callister, T. A.; Calloni, E.; Camp, J. B.; Cannon, K. C.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Diaz, J. Casanueva; Casentini, C.; Caudill, S.; Cavaglia, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Baiardi, L. Cerboni; Cerretani, G.; Cesarini, E.; Chakraborty, R.; Chalermsongsak, T.; Chamberlin, S. J.; Chan, M.; Chao, D. S.; Charlton, P.; Chassande-Mottin, E.; Chen, H. Y.; Chen, Y; Cheng, C.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Qian; Chua, S. E.; Chung, E.S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P. -F.; Colla, A.; Collette, C. G.; Cominsky, L.; Constancio, M., Jr.; Conte, A.; Conti, L.; Cook, D.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, A.C.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J. -P.; Countryman, S. T.; Couvares, P.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Craig, K.; Creighton, J. D. E.; Cripe, J.; Crowder, S. G.; Cumming, A.; Cunningham, A.L.; Cuoco, E.; Dal Canton, T.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Darman, N. S.; Dattilo, V.; Dave, I.; Daveloza, H. P.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; Debra, D.; Debreczeni, G.; Degallaix, J.; De laurentis, M.; Deleglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dergachev, V.A.; Rosa, R.; DeRosa, R. T.; DeSalvo, R.; Dhurandhar, S.; Diaz, M. C.; Di Fiore, L.; Giovanni, M.G.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Virgilio, A.; Dojcinoski, G.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Douglas, R.; Downes, T. P.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H. -B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Engels, W.; Essick, R. C.; Etzel, T.; Evans, T. M.; Evans, T. M.; Everett, R.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.M.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W. M.; Favata, M.; Fays, M.; Fehrmann, H.; Fejer, M. M.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Fiori, I.; Fiorucci, D.; Fisher, R. P.; Flaminio, R.; Fletcher, M; Fournier, J. -D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fricke, T. T.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H. A. G.; Gair, J. R.; Gammaitoni, L.; Gaonkar, S. G.; Garufi, F.; Gaur, G.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; George, J.; Gergely, L.; Germain, V.; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.P.; Glaefke, A.; Goetz, E.; Goetz, R.; Gondan, L.; Gonzalez, Idelmis G.; Castro, J. M. Gonzalez; Gopakumar, A.; Gordon, N. A.; Gorodetsky, M. L.; Gossan, S. E.; Lee-Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.M.; Greco, G.; Green, A. C.; Groot, P.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Hacker, J. J.; Buffoni-Hall, R.; Hall, E. D.; Hammond, G.L.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hanson, P.J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Hartman, M. T.; Haster, C. -J.; Haughian, K.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Hofman, D.; Hollitt, S. E.; Holt, K.; Holz, D. E.; Hopkins, P.; Hosken, D. J.; Hough, J.; Houston, E. A.; Howell, E. J.; Hu, Y. M.; Huang, S.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Idrisy, A.; Indik, N.; Ingram, D. R.; Inta, R.; Isa, H. N.; Isac, J. -M.; Isi, M.; Islas, G.; Isogai, T.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jang, D.H.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jimenez-Forteza, F.; Johnson, W.; Jones, I.D.; Jones, R.; Jonker, R. J. G.; Ju, L.; Haris, K.; Kalaghatgi, C. V.; Kalogera, V.; Kandhasamy, S.; Kang, G.H.; Kanner, J. B.; Karki, S.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kaur, T.; Kawabe, K.; Kawazoe, F.; Kefelian, F.; Kehl, M. S.; Keitel, D.; Kelley, D. B.; Kells, W.; Kennedy, R.E.; Key, J. S.; Khalaidovski, A.; Khalili, F. Y.; Khan, I.; Khan., S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chunglee; Kim, J.; Kim, K.; Kim, Nam-Gyu; Kim, Namjun; Kim, Y.M.; King, E. J.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Kleybolte, L.; Klimenko, S.; Koehlenbeck, S. M.; Kokeyama, K.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kringel, V.; Krolak, A.; Krueger, C.; Kuehn, G.; Kumar, P.; Kuo, L.; Kutynia, A.; Lackey, B. D.; Landry, M.; Lange, J.; Lantz, B.; Lasky, P. D.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lebigot, E. O.; Lee, C.H.; Lee, K.H.; Lee, M.H.; Lee, K.; Lenon, A.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levin, Y.; Levine, B. M.; Li, T. G. F.; Libson, A.; Littenberg, T. B.; Lockerbie, N. A.; Logue, J.; Lombardi, A. L.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lueck, H.; Lundgren, A. P.; Luo, J.; Lynch, R.; Ma, Y.; MacDonald, T.T.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magana-Sandoval, F.; Magee, R. M.; Mageswaran, M.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Marka, S.; Marka, Z.; Markosyan, A. S.; Maros, E.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R.M.; Martynov, D. V.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Meidam, J.; Melatos, A.; Mendell, G.; Mendoza-Gandara, D.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Mezzani, F.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, J.; Millhouse, M.; Minenkov, Y.; Ming, J.; Mirshekari, S.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moggi, A.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, B.C.; Moore, J.C.; Moraru, D.; Gutierrez Moreno, M.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, C. L.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, S.D.; Mukherjee, S.; Mukund, K. N.; Mullavey, A.; Munch, J.; Murphy, D. J.; Murray, P.G.; Mytidis, A.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Necula, V.; Nedkova, K.; Nelemans, G.; Gutierrez-Neri, M.; Neunzert, A.; Newton-Howes, G.; Nguyen, T. T.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Oberling, J.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J.; Oh, S. H.; Ohme, F.; Oliver, M. B.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; O'Shaughnessy, R.; Ott, C. D.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Paris, H. R.; Parker, W.S; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patricelli, B.; Patrick, Z.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Pereira, R.R.; Perreca, A.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Pletsch, H. J.; Poggiani, R.; Popolizio, P.; Post, A.; Powell, J.; Prasad, J.; Predoi, V.; Premachandra, S. S.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Purrer, M.; Qi, H.; Qin, J.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rakhmanov, M.; Rapagnani, P.; Raymond, V.; Razzano, M.; Re, V.; Read, J.; Reed, C. M.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Rew, H.; Ricci, F.; Riles, K.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, J. D.; Romano, R.; Romanov, G.; Romie, J. H.; Rosinska, D.; Rowan, S.; Ruediger, A.; Ruggi, P.; Ryan, K.A.; Sachdev, P.S.; Sadecki, T.; Sadeghian, L.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sanchez, E. J.; Sandberg, V.; Sandeen, B.; Sanders, J. R.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Sauter, O. E. S.; Savage, R. L.; Sawadsky, A.; Schale, P.; Schilling, R.; Schmidt, J; Schmidt, P.; Schnabel, R.B.; Schofield, R. M. S.; Schoenbeck, A.; Schreiber, K.E.C.; Schuette, D.; Schutz, B. F.; Scott, J.; Scott, M.S.; Sellers, D.; Sentenac, D.; Sequino, V.; Sergeev, A.; Serna, G.; Setyawati, Y.; Sevigny, A.; Shaddock, D. A.; Shahriar, M. S.; Shaltev, M.; Shao, Z.M.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, António Dias da; Simakov, D.; Singer, A; Singer, L. P.; Singh, A.; Singh, R.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, R. J. E.; Smith, N.D.; Smith, R. J. E.; Son, E. J.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Srivastava, A. K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stephens, B. C.; Stiles, C.D.; Stone, J.R.; Strain, K. A.; Straniero, N.; Stratta, G.; Strauss, N. A.; Strigin, S. E.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sutton, P. J.; Swinkels, B. L.; Szczepanczyk, M. J.; Tacca, M.D.; Talukder, D.; Tanner, D. B.; Tapai, M.; Tarabrin, S. P.; Taracchini, A.; Taylor, W.R.; Theeg, T.; Thirugnanasambandam, M. P.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Tomlinson, C.; Tonelli, M.; Torres, C. V.; Torrie, C. I.; Toyra, D.; Travasso, F.; Traylor, G.; Trifiro, D.; Tringali, M. C.; Trozzo, L.; Tse, M.; Turconi, M.; Tuyenbayev, D.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; Van Beuzekom, Martin; van den Brand, J. F. J.; Van Den Broeck, C.F.F.; Vander-Hyde, D. C.; van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Vass, S.; Vasuth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P.J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Vicere, A.; Vinciguerra, S.; Vine, D. J.; Vinet, J. -Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Voss, D. V.; Vousden, W. D.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, MT; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, M.; Wang, X.; Wang, Y.; Ward, R. L.; Warner, J.; Was, M.; Weaver, B.; Wei, L. -W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.M.; Wessels, P.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Williams, D.R.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Worden, J.; Wright, J.L.; Wu, G.; Yablon, J.; Yam, W.; Yamamoto, H.; Yancey, C. C.; Yap, M. J.; Yu, H.; Yvert, M.; Zadrozny, A.; Zangrando, L.; Zanolin, M.; Zendri, J. -P.; Zevin, M.; Zhang, F.; Zhang, L.; Zhang, M.; Zhang, Y.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, X. J.; Zucker, M. E.; Zuraw, S. E.; Zweizig, J.; Archibald, A. M.; Banaszak, S.; Berndsen, A.; Boyles, J.; Cardoso, R. F.; Chawla, P.; Cherry, A.; Dartez, L. P.; Day-Lewis, F.D.; Epstein, C. R.; Ford, A. J.; Flanigan, J.; Garcia, A.; Hessels, J. W. T.; Hinojosa, J; Jenet, F. A.; Karako-Argaman, C.; Kaspi, V. M.; Keane, E. F.; Kondratiev, V. I.; Kramer, M.; Leake, S.; Lorimer, D.; Lunsford, G.; Lynch, R. S.; Martinez, J. G.; Mata, A.; McLaughlin, M. A.; McPhee, C. A.; Penucci, T.; Ransom, S.; Roberts, M. S. E.; Rohr, M. D. W.; Stairs, I. H.; Stovall, K.; van Leeuwen, J.; Walker, A. N.; Wells, B. L.

    2016-01-01

    We present an archival search for transient gravitational-wave bursts in coincidence with 27 single-pulse triggers from Green Bank Telescope pulsar surveys, using the LIGO, Virgo, and GEO interferometer network. We also discuss a check for gravitational-wave signals in coincidence with Parkes fast

  1. Construction of a γ-γ and β-γ coincidence measurement system for precise determination of nuclear data

    International Nuclear Information System (INIS)

    Furutaka, Kazuyoshi; Nakamura, Shoji; Harada, Hideo; Katoh, Toshio

    1999-01-01

    A γ-γ and β-γ coincidence measurement system was constructed for the precise determination of nuclear data, such as thermal neutron capture cross sections and γ-ray emission probabilities. The validity of the system was tested by a γ-γ coincidence measurement with a 60 Co standard source. (author)

  2. Evaluating Coincident Relationships Between Obesity Incidence and Normal Weight Incidence From Birth Through Kindergarten for US Children.

    Science.gov (United States)

    Yeaton, William H; Shah, Megha K; Moss, Brian G

    2018-01-01

    We examine the concurrent relationship between obesity incidence and normal weight status incidence and prevalence in children between 9 months and kindergarten. Multistage, probability sample from the Early Childhood Longitudinal Study-Birth cohort. United States. Representative sample of US preschool children (n = 9950) followed from birth through kindergarten. From direct, anthropometric measures, we reported prevalence and incidence rates across 4 follow-up periods. In addition to prevalence and incidence rates, we reported risk ratios based on multiple definitions and estimated predicted probabilities of obesity and normal weight status using clinically meaningful body mass index (BMI)-for-age percentiles. Obesity prevalence (13%-20%) was much smaller than normal weight status prevalence (66%-70%). Lower socioeconomic status, Hispanic, and non-Hispanic black children had greater risk of obesity. During 9 months to kindergarten, obesity incidence decreased two-thirds (15.6%), while normal weight status incidence decreased almost one-half (44.6%). Coincidently, normal weight status incidence (ranged from 23% to 45%) was consistently and substantially higher than obesity incidence (ranged from 5% to 15%). During 4 years to kindergarten, the obesity risk for overweight children was 13 times higher than that for normal weight status children. Overall rates of obese and normal weight incidence were substantial at 9 months, trended lower, but remained high through kindergarten. At 4 years to kindergarten, children with relatively high initial BMI were very likely to become obese but far less likely to achieve normal weight status.

  3. 4πβ(PS)-4πγ(GE) list-mode coincidence counter and its applications.

    Science.gov (United States)

    Yamada, T; Kawada, Y; Sato, Y

    2016-03-01

    We developed a 4πβ-4πγ counter composed of a 4π plastic scintillation detector and a well-type Ge detector, employing digital coincidence counting and data storage in list-mode. In both of the β- and γ-channels, the amplified pulses from a linear amplifier feed the input channel of the digitizer directly via delay circuits. A signal from the peak-hold of each channel is fed to a sliding scale ADC (14bits, 200MHz clock) after peak detection and converted into 13bit digital data, registered along with a time stamp and event channel allowing various data analysis to be implemented offline. When employing multiple gamma window settings, a weighted average of each apparent efficiency might be introduced to improve the efficiency functions. This idea was investigated along with reasonable estimates of the weighing factors, and activity measurements of (59)Fe using this system are presented. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction

    International Nuclear Information System (INIS)

    Torres-Espallardo, I; Spanoudaki, V; Ziegler, S I; Rafecas, M; McElroy, D P

    2008-01-01

    Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Simulated singles list-mode data of the MADPET-II small animal PET scanner were used as input. The simulations have been performed using the GATE simulation toolkit. Several sources with different geometries have been employed. We evaluated the number of random events using three methods: delayed window (DW), singles rate (SR) and time histogram fitting (TH). Since the GATE simulations allow random and true coincidences to be distinguished, a comparison between the number of random coincidences estimated using the standard methods and the number obtained using GATE was performed. An overestimation in the number of random events was observed using the DW and SR methods. This overestimation decreases for LETs higher than 255 keV. It is additionally reduced when the single events which have undergone a Compton interaction in crystals before being detected are removed from the data. These two observations lead us to infer that the overestimation is due to inter-crystal scatter. The effect of this mismatch in the reconstructed images is important for quantification because it leads to an underestimation of activity. This was shown using a hot-cold-background source with 3.7 MBq total activity in the background region and a 1.59 MBq total activity in the hot region. For both 200 keV and 400 keV LET, an overestimation of random coincidences for the DW and SR methods was observed, resulting in approximately 1.5% or more (at 200 keV LET: 1.7% for DW and 7% for SR) and less than 1% (at 400 keV LET: both methods) underestimation of activity within the background region. In almost all cases, images obtained by compensating for random events in the reconstruction

  5. Absolute standardization of radionuclides with complex decay by the peak-sum coincidence method and photon spectrometry with HPGe detector; Padronização primária de radionuclídeos com decaimento complexo pelo método de coincidência pico-soma espectrometria de fótons com detector GeHP

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Ronaldo Lins da

    2017-07-01

    This study aims to present a new methodology for absolute standardization of {sup 133}Ba, which is a complex decay radionuclide, using the peak-sum coincidence method associated with gamma spectrometry with a high resolution germanium detector. The use of the method of direct multiplication of matrices allowed identifying all the energies of sum coincidence, as well as their probabilities of detection, which made possible the calculation of the probabilities of detecting the energies of interferences. In addition, with the use of deconvolution software it was possible to obtain the areas of energy without interference of other sums, and by means of the deduced equation for the peak sum method, it was possible to standardize {sup 133}Ba. The result of the activity was compared with those found by the absolute methods existing in the LNMRI, where the result obtained by coincidence peak-sum was highlighted among all. The estimated uncertainties were below 0.30%, compatible with the results found in the literature by other absolute methods. Thus, it was verified that the methodology was able to standardize radionuclide {sup 133}Ba with precision, accuracy, easiness and quickness. The relevance of this doctoral thesis is to provide the National Metrology Laboratory of Ionizing Radiation (LNMRI) with a new absolute standardization methodology for complex decay radionuclides. (author)

  6. Multiple Sclerosis

    Science.gov (United States)

    Multiple sclerosis (MS) is a nervous system disease that affects your brain and spinal cord. It damages the ... attacks healthy cells in your body by mistake. Multiple sclerosis affects women more than men. It often begins ...

  7. Multiple Endpoints

    OpenAIRE

    Parys, Dariusz

    2007-01-01

    In ANOVA we are mainly based on inter-treatment comparisons. Another common problems arising in biometric studies (especially in biomedical studies) is that of comparing two groups of patients (treatment and a control group) based on multiple response (called multiple endpoints). In this paper we present the continuos and discrete approaches to multiple endpoints. In the case of continuous multiple endpoints we have common assumption in that the covariance matrices in group ...

  8. Artefactual multiplicity

    DEFF Research Database (Denmark)

    Bjørn, Pernille; Hertzum, Morten

    2011-01-01

    Whiteboards are highly important to the work in emergency departments (EDs). As a collaborative technology ED whiteboards are usually placed in the dynamic centre of the ED, and all ED staff will approach the whiteboard regularly to organize their individual yet interdependent work. Currently, di...... this characteristic of heterogeneous artefacts; namely artefactual multiplicity. Artefactual multiplicity identifies not only the multiple functions of heterogeneous artefacts but also the intricate relations between these multiple functionalities....

  9. Finger Multiplication

    Science.gov (United States)

    Simanihuruk, Mudin

    2011-01-01

    Multiplication facts are difficult to teach. Therefore many researchers have put a great deal of effort into finding multiplication strategies. Sherin and Fuson (2005) provided a good survey paper on the multiplication strategies research area. Kolpas (2002), Rendtorff (1908), Dabell (2001), Musser (1966) and Markarian (2009) proposed the finger…

  10. Magnetized relativistic electron-ion plasma expansion

    Science.gov (United States)

    Benkhelifa, El-Amine; Djebli, Mourad

    2016-03-01

    The dynamics of relativistic laser-produced plasma expansion across a transverse magnetic field is investigated. Based on a one dimensional two-fluid model that includes pressure, enthalpy, and rest mass energy, the expansion is studied in the limit of λD (Debye length) ≤RL (Larmor radius) for magnetized electrons and ions. Numerical investigation conducted for a quasi-neutral plasma showed that the σ parameter describing the initial plasma magnetization, and the plasma β parameter, which is the ratio of kinetic to magnetic pressure are the key parameters governing the expansion dynamics. For σ ≪ 1, ion's front shows oscillations associated to the break-down of quasi-neutrality. This is due to the strong constraining effect and confinement of the magnetic field, which acts as a retarding medium slowing the plasma expansion.

  11. Theory of Electron-Ion Collisions

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Donald C

    2009-10-02

    Collisions of electrons with atoms and ions play a crucial role in the modeling and diagnostics of fusion plasmas. In the edge and divertor regions of magnetically confined plasmas, data for the collisions of electrons with neutral atoms and low charge-state ions are of particular importance, while in the inner region, data on highly ionized species are needed. Since experimental measurements for these collisional processes remain very limited, data for such processes depend primarily on the results of theoretical calculations. Over the period of the present grant (January 2006 - August 2009), we have made additional improvements in our parallel scattering programs, generated data of direct fusion interest and made these data available on The Controlled Fusion Atomic Data Center Web site at Oak Ridge National Laboratory. In addition, we have employed these data to do collsional-radiative modeling studies in support of a variety of experiments with magnetically confined fusion plasmas.

  12. Electron-ion recombination at low energy

    International Nuclear Information System (INIS)

    Andersen, L.H.

    1993-01-01

    The work is based on results obtained with a merged-beams experiment. A beam of electronics with a well characterized density and energy distribution was merged with a fast, monoenergetic ion beam. Results have been obtained for radiative recombination and dielectronic recombination at low relative energies (0 to ∼70eV). The obtained energy resolution was improved by about a factor of 30. High vacuum technology was used to suppress interactions with electrons from the environments. The velocity distribution of the electron beam was determined. State-selective dielectronic-recombination measurements were performable. Recombination processes were studied. The theoretical background for radiative recombination and Kramers' theory are reviewed. The quantum mechanical result and its relation to the semiclassical theory is discussed. Radiative recombination was also measured with several different non-bare ions, and the applicability of the semiclassical theory to non-bare ions was investigated. The use of an effective charge is discussed. For dielectronic recombination, the standard theoretical approach in the isolated resonance and independent-processes approximation is debated. The applicability of this method was tested. The theory was able to reproduce most of the experimental data except when the recombination process was sensitive to couplings between different electronic configurations. The influence of external perturbing electrostatic fields is discussed. (AB) (31 refs.)

  13. Secondary electron ion source neutron generator

    Science.gov (United States)

    Brainard, John P.; McCollister, Daryl R.

    1998-01-01

    A neutron generator employing an electron emitter, an ion source bombarded by the electrons from the electron emitter, a plasma containment zone, and a target situated between the plasma containment zone and the electron emitter. The target contains occluded deuterium, tritium, or a mixture thereof

  14. Clinical value of 18F-FDG coincidence imaging for diagnosis of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Ning Yanli; Lou Cen; Huang Zhongke; Shi Guohua; Chen Dongfang; Mu Da

    2012-01-01

    Objective: To investigate the value of 18 F-FDG coincidence imaging for diagnosis of nasopharyngeal carcinoma. Methods: A total of 45 patients with nasopharyngeal carcinoma (33 males and 12 females, average age (55.56 ± 13.50) years), who underwent 18 F-FDG coincidence imaging before treatment, were studied retrospectively. The images of 18 F-FDG coincidence imaging (GE Millennium VG SPECT) and MRI were analyzed. The radioactivity ratio of the accumulated regions to cerebellum (T/NT)was calculated by ROI technique. The volume of nasopharyngeal carcinoma was recorded by MRI. The positive rates of 18 F-FDG coincidence imaging and EB virus-related antibody measurements were compared by paired χ 2 test. The correlation between T/NT ratios and tumor volumes were tested by Pearson correlation, and then ROC curves were established. The T/NT ratios and tumor volumes of different groups (different first symptoms, clinical stages, T stages, pathological classification and outcomes, with or without lymph node enlargement) were compared by t-test and rank sum test. Results: The positive rate of 18 F-FDG coincidence imaging was 97.78% (44/45), and the positive rate of EB virus-related antibody measurement was 95.56% (43/45, χ 2 =1.33, P>0.05). The T/NT ratio (2.439 ±1.119) and tumor volume ((7.311 ± 8.280) cm 3 ) of primary lesions had a positive correlation (r=0.463, P<0.05). The cut-off values of T/NT ratio and the tumor volume were 2.396 and 7.348 cm 3 , respectively, by ROC curves. T/NT ratios in groups with or without first symptom of epistaxis (2.847 ± 1.254 vs 2.082 ± 0.863, t=-2.409) and groups with or without facial numbness (2.855 ± 1.261 vs 2.134 ± 0.913, t=-2.225) were both significantly different (both P<0.05). T/NT ratios of differentiated and undifferentiated cancer were 2.266 ± 0.997 and 2.971 ± 1.351, respectively (t=-2.018, P<0.05). There was a significant difference of tumor volumes between groups with or without facial numbness (t=-2.684, P<0

  15. Disintegration rate of Tc -99m and In -111 radioactive solutions in coincidence systems

    International Nuclear Information System (INIS)

    Brito, Andreia Barreto de

    2011-01-01

    The 111 In and 99 mTc standardization in a 4πβ-γ coincidence system is described. The 111 In was produced by the reaction of 111 Cd (p, n) 111 In in the cyclotron. The 111 In decays with a half life of 2.8 days by electron capture process, populating the excited levels of 111 Cd, emitting two main gamma rays with energies of 171 keV and 245 keV. The 99m Tc decay with a half life of 6.007 h for isomeric transition, from the radioactive decay of 99 Mo. 111 In standardization was carried out in a 4πβ-γ system, consisted of a gas flow proportional counter with 4π geometry coupled to a pair of NaI(Tl) scintillation counter with conventional electronics. The gamma window was set comprising the (171 keV + 245 keV) total absorption energy peaks. The choice of the window was based on the analysis of the extrapolation curves prediction, obtained by Monte Carlo simulation. The 99 mTc standardization has been accomplished by the 4πβ-γ coincidence method using a thin window proportional counter in a 4π geometry coupled to a single NaI(Tl) scintillation counter. The beta efficiency was varied by electronic discrimination using a software coincidence counting system (SCS). Two windows were selected for the gamma channel: one at 140 keV gamma ray and the other at 20 keV X ray total absorption peaks. The result of the experimental activity of 111 In two solutions agree with the results obtained by Monte Carlo simulation. The experimental activities of 99m Tc for the two gamma windows are in agreement within the experimental uncertainty, indicating that the adopted methodology is adequate. (author)

  16. A simultaneous beta and coincidence-gamma imaging system for plant leaves

    Science.gov (United States)

    Ranjbar, Homayoon; Wen, Jie; Mathews, Aswin J.; Komarov, Sergey; Wang, Qiang; Li, Ke; O'Sullivan, Joseph A.; Tai, Yuan-Chuan

    2016-05-01

    Positron emitting isotopes, such as 11C, 13N, and 18F, can be used to label molecules. The tracers, such as 11CO2, are delivered to plants to study their biological processes, particularly metabolism and photosynthesis, which may contribute to the development of plants that have a higher yield of crops and biomass. Measurements and resulting images from PET scanners are not quantitative in young plant structures or in plant leaves due to poor positron annihilation in thin objects. To address this problem we have designed, assembled, modeled, and tested a nuclear imaging system (simultaneous beta-gamma imager). The imager can simultaneously detect positrons ({β+} ) and coincidence-gamma rays (γ). The imaging system employs two planar detectors; one is a regular gamma detector which has a LYSO crystal array, and the other is a phoswich detector which has an additional BC-404 plastic scintillator for beta detection. A forward model for positrons is proposed along with a joint image reconstruction formulation to utilize the beta and coincidence-gamma measurements for estimating radioactivity distribution in plant leaves. The joint reconstruction algorithm first reconstructs beta and gamma images independently to estimate the thickness component of the beta forward model and afterward jointly estimates the radioactivity distribution in the object. We have validated the physics model and reconstruction framework through a phantom imaging study and imaging a tomato leaf that has absorbed 11CO2. The results demonstrate that the simultaneously acquired beta and coincidence-gamma data, combined with our proposed joint reconstruction algorithm, improved the quantitative accuracy of estimating radioactivity distribution in thin objects such as leaves. We used the structural similarity (SSIM) index for comparing the leaf images from the simultaneous beta-gamma imager with the ground truth image. The jointly reconstructed images yield SSIM indices of 0.69 and 0.63, whereas the

  17. Coinciding exercise with peak serum caffeine does not improve cycling performance.

    Science.gov (United States)

    Skinner, Tina L; Jenkins, David G; Taaffe, Dennis R; Leveritt, Michael D; Coombes, Jeff S

    2013-01-01

    To investigate whether coinciding peak serum caffeine concentration with the onset of exercise enhances subsequent endurance performance. Randomised, double-blind, crossover. In this randomised, placebo-controlled, double-blind crossover study, 14 male trained cyclists and triathletes (age 31±5year, body mass 75.4±5.7 kg, VO₂max 69.5±6.1 mL kg⁻¹ min⁻¹ and peak power output 417±35W, mean±SD) consumed 6 mg kg(-1) caffeine or a placebo either 1h (C(1h)) prior to completing a 40 km time trial or when the start of exercise coincided with individual peak serum caffeine concentrations (C(peak)). C(peak) was determined from a separate 'caffeine profiling' session that involved monitoring caffeine concentrations in the blood every 30 min over a 4h period. Following caffeine ingestion, peak serum caffeine occurred 120 min in 12 participants and 150 min in 2 participants. Time to complete the 40 km time trial was significantly faster (2.0%; p=0.002) in C(1h) compared to placebo. No statistically significant improvement in performance was noted in the C(peak) trial versus placebo (1.1%; p=0.240). Whilst no differences in metabolic markers were found between C(peak) and placebo conditions, plasma concentrations of glucose (p=0.005), norepinephrine and epinephrine (p≤0.002) were higher in the C(1h) trial 6 min post-exercise versus placebo. In contrast to coinciding peak serum caffeine concentration with exercise onset, caffeine consumed 60 min prior to exercise resulted in significant improvements in 40 km time trial performance. The ergogenic effect of caffeine was not found to be related to peak caffeine concentration in the blood at the onset of endurance exercise. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Estimating accidental coincidences for pixelated PET detectors and singles list-mode acquisition

    International Nuclear Information System (INIS)

    Rafecas, M.; Torres, I.; Spanoudaki, V.; McElroy, D.P.; Ziegler, S.I.

    2007-01-01

    We have studied the validity of random estimation techniques for various low energy thresholds (LETs) and single list-mode data sets in small animal PET. While a LET below 255 keV helps to increase the sensitivity, it also results in an increase of random coincidences and inter-crystal scatter (ICS). The study is carried out for MADPET-II, a dual-layer positron emission tomography (PET) scanner prototype consisting of LSO crystals read out individually by APDs. The data are acquired in singles list-mode format, and coincidences are computed post-acquisition. To estimate randoms, we have used the delayed coincidence window method (DW), and the singles rate model (SR). Various phantoms were simulated using GATE. For LETs under 255 keV, the number of random events R, estimated using the SR and the DW methods, is larger than the number of randoms which was directly computed from GATE simulations, and R(SR)>R(DW)>R(GATE). The higher the LET, the smaller the overestimation. For LETs >255 keV, R(DW)/R(GATE) ∼1. If scattered singles were excluded from the file, this discrepancy between R(DW or SR) and R(GATE) significantly diminished. This fact points out to ICS as the effect responsible for the mismatch, since for LETs lower than 255 keV, all singles related to an ICS event can be detected independently, thus altering the singles rate. Therefore, if low LETs are used, random estimation techniques should account for ICS

  19. Performance demonstration of 4πβ(LS)-γ coincidence counting system for standardization of radionuclides with complex decay scheme.

    Science.gov (United States)

    Kulkarni, D B; Anuradha, R; Joseph, Leena; Kulkarni, M S; Tomar, B S

    2016-02-01

    A standardization of (134)Cs and (131)I was carried out in order to demonstrate the performance and applicability of the 4πβ(LS)-γ coincidence counting system for standardization of radionuclides with complex decay scheme. The coincidence analyzer, capable of analyzing coincidence between beta and two gamma windows simultaneously, was developed and used for the standardization. The use of this dual coincidence analyzer has reduced the total experimental time by half. The activity concentrations obtained using the 4πβ(LS)-γ coincidence counting system, a 4πβ(PC)-γ coincidence counting system, and the CIEMAT/NIST method are in excellent agreement with each other within uncertainty limits and hence demonstrates its performance for standardization of radionuclides decaying with complex decay scheme. Hence use of this 4πβ(LS)-γ coincidence counting system can be an alternative method suitable to standardize radionuclides with complex decay scheme with acceptable precision. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Positron annihilation in polypropylene studied by lifetime and coincidence Doppler-broadening spectroscopy

    Science.gov (United States)

    Djourelov, N.; He, C.; Suzuki, T.; Shantarovich, V. P.; Ito, Y.; Kondo, K.; Ito, Y.

    2003-12-01

    The momentum density distributions (MDDs) of electrons taking part in the annihilation processes in polypropylene (PP) have been measured by coincidence Doppler-broadening spectroscopy. MDDs at the beginning of measurements to those at the saturation level of Ps formation have been compared in order to follow the possible changes in concentration of carbonyl groups (CG). A high initial CG concentration in PP has been observed, while for antioxidant-containing PP no significant presence of CG has been detected, and no changes have been observed during positron irradiation.

  1. Calibration and performance testing of the IAEA Aquila Active Well Coincidence Counter (Unit 1)

    International Nuclear Information System (INIS)

    Menlove, H.O..; Siebelist, R.; Wenz, T.R.

    1996-01-01

    An Active Well Coincidence Counter (AWCC) and a portable shift register (PSR-B) produced by Aquila Technologies Group, Inc., have been tested and cross-calibrated with existing AWCCs used by the International Atomic Energy Agency (IAEA). This report summarizes the results of these tests and the cross-calibration of the detector. In addition, updated tables summarizing the cross-calibration of existing AWCCs and AmLi sources are also included. Using the Aquila PSR-B with existing IAEA software requires secondary software also supplied by Aquila to set up the PSR-B with the appropriate measurement parameters

  2. Constructing coincident indices of economic activity for the Latin American economy

    Directory of Open Access Journals (Sweden)

    João Victor Issler

    2013-03-01

    Full Text Available This paper has three main contributions. The first is to propose an individual coincident indicator for the following Latin American countries: Argentina, Brazil, Chile, Colombia and Mexico. In order to obtain similar series to those traditionally used in business-cycle research in constructing coincident indices (output, sales, income and employment we were forced to back-cast several individual country series which were not available in a long time-series span. The second contribution is to establish a chronology of recessions for these countries, covering the period from 1980 to 2012 on a monthly basis. Based on this chronology, the countries are compared in several respects. The final contribution is to propose an aggregate coincident indicator for the Latin American economy, which weights individual-country composite indices. Finally, this indicator is compared with the coincident indicator (The Conference Board - TCB of the U.S. economy. We find that the U.S. indicator Granger-causes the Latin American indicator in statistical testsEsse artigo tem 3 contribuições à literatura de ciclos de negócios. A primeira é a de construir indicadores coincidentes de atividade econômica para Argentina, Brasil, Chile, Colômbia e México, usando pesos idênticos para as séries de Emprego, Produção, Renda, e Vendas. Para tal, tivemos que fazer o back-cast de algumas séries chave para poder construir esses indicadores. A segunda é a de estabelecer uma cronologia de recessões para esses países no período 1980-2012 em bases mensais. Com base na última, fazemos comparações em várias dimensões. Finalmente, nossa última contribuição é propor um índice coincidente agregado para a América Latina, que é comparado ao índice agregado dos EUA. Esta comparação indica que o índice coincidente dos EUA Granger-causa o da América Latina, mas a recíproca não é verdadeira

  3. Efficiency-optimized low-cost TDPAC spectrometer using a versatile routing/coincidence unit

    International Nuclear Information System (INIS)

    Renteria, M.; Bibiloni, A. G.; Darriba, G. N.; Errico, L. A.; Munoz, E. L.; Richard, D.; Runco, J.

    2008-01-01

    A highly efficient, reliable, and low-cost γ-γ TDPAC spectrometer, PACAr, optimized for 181 Hf-implanted low-activity samples, is presented. A versatile EPROM-based routing/coincidence unit was developed and implemented to be use with the memory-card-based multichannel analyzer hosted in a personal computer. The excellent energy resolution and very good overall resolution and efficiency of PACAr are analyzed and compare with advanced and already tested fast-fast and slow-fast PAC spectrometers.

  4. Efficiency-optimized low-cost TDPAC spectrometer using a versatile routing/coincidence unit

    Energy Technology Data Exchange (ETDEWEB)

    Renteria, M., E-mail: renteria@fisica.unlp.edu.ar; Bibiloni, A. G.; Darriba, G. N.; Errico, L. A.; Munoz, E. L.; Richard, D.; Runco, J. [Universidad Nacional de La Plata, Departamento de Fisica, Facultad de Ciencias Exactas (Argentina)

    2008-01-15

    A highly efficient, reliable, and low-cost {gamma}-{gamma} TDPAC spectrometer, PACAr, optimized for {sup 181}Hf-implanted low-activity samples, is presented. A versatile EPROM-based routing/coincidence unit was developed and implemented to be use with the memory-card-based multichannel analyzer hosted in a personal computer. The excellent energy resolution and very good overall resolution and efficiency of PACAr are analyzed and compare with advanced and already tested fast-fast and slow-fast PAC spectrometers.

  5. Hypohidrotic ectodermal dysplasia and immunodeficiency with coincident NEMO and EDA Mutations

    Directory of Open Access Journals (Sweden)

    Michael D. Keller

    2011-11-01

    Full Text Available Ectodermal dysplasias (ED are uncommon genetic disorders resulting in abnormalities in ectodermally-derived structures. Though many ED-associated genes have been described, the NF-κB Essential Modulator (NEMO encoded by the IKBKG gene is unique in that mutations also result in severe humoral and cellular immunologic defects. We describe three unrelated kindreds with defects in both EDA and IKBKG resulting from an X-chromosome crossover. This demonstrates the importance of thorough immunologic consideration of patients with ED even when an EDA etiology is confirmed, and raises the possibility of a specific phenotype arising from coincident mutations in EDA and IKBKB.

  6. Extraction of plate bending stiffness from coincidence angles of sound transmission measurements.

    Science.gov (United States)

    Anderson, Brian E; Shaw, Matthew D; Harker, Blaine M

    2015-01-01

    The bending stiffness in a homogeneous, isotropic, thin plate is experimentally derived from measurements of coincidence angles extracted from supercritical sound transmission versus frequency measurements. A computer controlled turn table rotates a plate sample and a receiver array, placed in the near field of the plate. The array is used to track the transmitted sound through the plate, generated by a far-field stationary source, using beam forming. The array technique enables measurement of plates measuring only one wavelength in width. Two examples are used for proof of concept, including an aluminum plate in air and an alumina plate under water.

  7. Uranium cross-calibration measurements using an active well coincidence counter

    International Nuclear Information System (INIS)

    Nikolaev, V.; Prochine, I.; Smirnov, V.; Ensslin, N.; Carillo, L.

    1998-01-01

    This paper reports on the cross-calibration of an Active Well Coincidence Counter for use in the Materials Protection, Control, and Accountability Graduate Program at the Moscow State Engineering Physics Institute (MEPhI). The cross-calibration procedure and its application to nuclear material types available at MEPhI for instructional purposes is described. Cross-calibration results at Los Alamos and initial applications at MEPhI are summarized. Based on the results so far, the authors conclude that the cross-calibration approach seems useful, with good prospects for potential applications at other Russian and US Dept. of Energy facilities

  8. Phantom dark energy with varying-mass dark matter particles: Acceleration and cosmic coincidence problem

    International Nuclear Information System (INIS)

    Leon, Genly; Saridakis, Emmanuel N.

    2010-01-01

    We investigate several varying-mass dark matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.

  9. beta sup + -gamma coincidence positron lifetime spectrometer with positron energy selection by electromagnetic lens

    CERN Document Server

    Chalermkarnnon, P; Araki, H; Shirai, Y; Shishido, I

    2002-01-01

    A beta sup + -gamma coincidence positron lifetime spectrometer equipped with two electromagnetic lenses was constructed. The electromagnetic lens was used to have energy-selected positron beam. It accomplished a time resolution of 385 ps (FWHM) for the total system with a Pilot U plastic scintillator. By using a silicon avalanche diode instead of Pilot U plastic scintillator to initiate start timing signals, the time resolution was improved to 345 ps (FWHM). With this method, in-situ positron lifetime measurements at high temperatures or under high stresses can be attained easily. (author)

  10. Absolute measurements of the alpha-gamma emitters activities by a sum-coincidence method

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1982-01-01

    The absolute activity of U-235 contained in a UO 2 sample, using a sum-coincidence circuit which selected only the alpha particles which were simultaneous with the well known 184 Kev gamma radiation from Th-231. The alpha particles were detected by ZnS(Ag) scintillator specially designed to show its maximun efficiency for U-235 alpha particles, whereas the gamma radiation was detected by NaI(Tl) scintillation detector. The values obtained for the half-life of U-235 was compared with data from various observers using different experimental techniques. (Author) [pt

  11. Cogroups in the category of connected graded algebras whose inverse and antipode coincide

    OpenAIRE

    Kihara, Hiroshi

    2013-01-01

    Let A be a cogroup in the category of connected graded algebras over a commutative ring R. Let nu denote the inverse of A and chi the antipode of the underlying Hopf algebra of A. We clarify the differences and similarities of nu and chi, and show that nu coincides with chi if and only if A is commutative as a graded algebra. Let A^co_CG be the category of cogroups satisfying these equivalent conditions. If R is a field, the category A^co_CG is completely determined. We also establish an equi...

  12. Method for improving the gamma-transition cascade spectra amplitude resolution during coincidence code computerized processing

    International Nuclear Information System (INIS)

    Sukhovoj, A.M.; Khitrov, V.A.

    1984-01-01

    A method of unfolding the differential γ-cascade spectra during radiation capture of slow neutrons based on the computeri-- zed processing of the results of measurements performed, by means of a spectrometer with two Ge(Li) detectors is suggested. The efficiency of the method is illustrated using as an example the spectrum of 35 Cl(n, γ) reaction corresponding to the 8580 keV peak. It is shown that the above approach permits to improve the resolution by 1.2-2.6 times without decrease in registration efficiency within the framework of the method of coincidence pulse amplitude summation

  13. 65Zn and 133Ba standardizing by photon-photon coincidence counting

    Science.gov (United States)

    Loureiro, Jamir S.; da Cruz, Paulo A. L.; Iwahara, Akira; Delgado, José U.; Lopes, Ricardo T.

    2018-03-01

    The LNMRI/Brazil has deployed a system using X-gamma coincidence technique for the standardizing radionuclide, which present simple and complex decay scheme with X-rays of energy below 100 keV. The work was carried on radionuclide metrology laboratory using a sodium iodide detector, for gamma photons, in combination with a high purity germanium detector for X-rays. Samples of 65Zn and 133Ba were standardized and the results for both radionuclides showed good precision and accuracy when compared with reference values. The standardization differences were 0.72 % for 65Zn and 0.48 % for 133Ba samples.

  14. Study of the continuum in heavy ion inelastic spectra by light particle coincidence measurements

    International Nuclear Information System (INIS)

    Scarpaci, J.A.; Blumenfeld, Y.; Chomaz, P.; Frascaria, N.; Garron, J.P.; Roynette, J.C.; Suomijarvi, T.; Van der Woude, A.; Alamanos, N.; Fernandez, B.; Gillibert, A.; Van der Woude, A.; Lepine, A.

    1990-01-01

    The continuum in heavy ion inelastic spectra contains, in addition to the excitation of target nucleus states, contributions from pick-up break-up and knock out reactions. In the case of the 40 Ca + 40 Ca collision at 50 MeV/N these contributions are separated and their relative importance assessed by the measurement of light charged particles in coincidence with the inelastically scattered fragments. The pick-up break-up contribution is found to make up less than half of the cross section at high excitation energies, conversely, the knock out process is important

  15. MULTIPLE OBJECTS

    Directory of Open Access Journals (Sweden)

    A. A. Bosov

    2015-04-01

    Full Text Available Purpose. The development of complicated techniques of production and management processes, information systems, computer science, applied objects of systems theory and others requires improvement of mathematical methods, new approaches for researches of application systems. And the variety and diversity of subject systems makes necessary the development of a model that generalizes the classical sets and their development – sets of sets. Multiple objects unlike sets are constructed by multiple structures and represented by the structure and content. The aim of the work is the analysis of multiple structures, generating multiple objects, the further development of operations on these objects in application systems. Methodology. To achieve the objectives of the researches, the structure of multiple objects represents as constructive trio, consisting of media, signatures and axiomatic. Multiple object is determined by the structure and content, as well as represented by hybrid superposition, composed of sets, multi-sets, ordered sets (lists and heterogeneous sets (sequences, corteges. Findings. In this paper we study the properties and characteristics of the components of hybrid multiple objects of complex systems, proposed assessments of their complexity, shown the rules of internal and external operations on objects of implementation. We introduce the relation of arbitrary order over multiple objects, we define the description of functions and display on objects of multiple structures. Originality.In this paper we consider the development of multiple structures, generating multiple objects.Practical value. The transition from the abstract to the subject of multiple structures requires the transformation of the system and multiple objects. Transformation involves three successive stages: specification (binding to the domain, interpretation (multiple sites and particularization (goals. The proposed describe systems approach based on hybrid sets

  16. Coincidences in analysis: Sigmund Freud and the strange case of Dr Forsyth and Herr von Vorsicht.

    Science.gov (United States)

    Pierri, Maria

    2010-08-01

    Freud's interest in thought transference opens the possibility for psychoanalytic research on the primary preverbal language and the maternal function, which the emphasis on verbal and paternal communication had hidden in the background of the setting. The author advances a new interpretation of coincidences in analysis and of the psychopathology of everyday life of the setting. Starting from a strange coincidence, new hypotheses are submitted following additional readings of the unpublished manuscript of the 'Forsyth case', recovered by the author, in regard to a significant moment of transformation, both in Freud and in psychoanalysis, at the end of the war. This phase corresponds first to a change of language, from German to English, as well as to the foundation of the International Journal of Psychoanalysis by Ernest Jones. In particular, the roots of the metapsychological turn of the 1920s are explored, together with the opening of private and productive thoughts in the area of 'telepathy' that joined Freud, Ferenczi, and Anna Freud in a true 'dialogue of unconsciouses'. The free association between A Child Is Being Beaten, Beyond the Pleasure Principle, and the clinical experience with 'Herr B.' is outlined in order to understand Freud's heroic self-analysis at the time when he was treating his daughter Anna and grieving the death of his beloved Sophie. Copyright © 2010 Institute of Psychoanalysis.

  17. Advances in threshold photoelectron spectroscopy (TPES) and threshold photoelectron photoion coincidence (TPEPICO).

    Science.gov (United States)

    Baer, Tomas; Tuckett, Richard P

    2017-04-12

    The history and evolution of molecular threshold photoelectron spectroscopy and threshold photoelectron photoion coincidence spectroscopy (TPEPICO) over the last fifty years are reviewed. Emphasis is placed on instrumentation and the extraction of dynamical information about energy selected ion dissociation, not on the detailed spectroscopy of certain molecules. Three important advances have expanded greatly the power of the technique, and permitted its implementation on modern synchrotron radiation beamlines. The use of velocity focusing of threshold electrons onto an imaging detector in the 1990s simultaneously improved the sensitivity and electron energy resolution, and also facilitated the subtraction of hot electron background in both threshold electron spectroscopy and TPEPICO studies. The development of multi-start multi-stop collection detectors for both electrons and ions in the 2000s permitted the use of the full intensity of modern synchrotron radiation thereby greatly improving the signal-to-noise ratio. Finally, recent developments involving imaging electrons in a range of energies as well as ions onto separate position-sensitive detectors has further improved the collection sensitivity so that low density samples found in a variety of studies can be investigated. As a result, photoelectron photoion coincidence spectroscopy is now well positioned to address a range of challenging problems that include the quantitative determination of compositions of isomer mixtures, and the detection and spectroscopy of free radicals produced in pyrolysis or discharge sources as well as in combustion studies.

  18. Hypernuclear weak decay experiments at KEK: n-n and n-p coincidence measurement

    International Nuclear Information System (INIS)

    Outa, H.; Ajimura, S.; Aoki, K.; Banu, A.; Bhang, H.C.; Fukuda, T.; Hashimoto, O.; Hwang, J.I.; Kameoka, S.; Kang, B.H.; Kim, E.H.; Kim, J.H.; Kim, M.J.; Maruta, T.; Miura, Y.; Miyake, Y.; Nagae, T.; Nakamura, M.; Nakamura, S.N.; Noumi, H.; Okada, S.; Okayasu, Y.; Park, H.; Saha, P.K.; Sato, Y.; Sekimoto, M.; Takahashi, T.; Tamura, H.; Tanida, K.; Toyoda, A.; Tsukada, K.; Watanabe, T.; Yim, H.J.

    2005-01-01

    We performed a coincidence measurement of two nucleons emitted from the nonmesonic weak decay (NMWD) of 5 Λ He and 12 Λ C formed via the (π+,K+) reaction. In both of n+p and n+n pair coincidence spectra, we observed a clean back-to-back correlation coming from the two-body decay of Λp->np and Λn->nn, respectively. We obtained the ratio of the nucleon pair numbers, Nnn/Nnp ( 5 Λ He)=0.45-bar +/--bar 0.11-bar (stat)-bar +/--bar 0.03-bar (syst) in the kinematic region of cosθNN-0.8. Since each decay mode was exclusively detected, the measured ratio should be close to the ratio of Γ(Λp->nn)/Γ(Λn->np). The Γn/Γp ratio was measured also for the NMWD of 12 Λ C. It is also close to 0.5. Those ratios are consistent with recent theoretical calculations based on the heavy meson/direct quark exchange picture

  19. Correlation-Based Amplitude Estimation of Coincident Partials in Monaural Musical Signals

    Directory of Open Access Journals (Sweden)

    Jayme Garcia Arnal Barbedo

    2010-01-01

    Full Text Available This paper presents a method for estimating the amplitude of coincident partials generated by harmonic musical sources (instruments and vocals. It was developed as an alternative to the commonly used interpolation approach, which has several limitations in terms of performance and applicability. The strategy is based on the following observations: (a the parameters of partials vary with time; (b such a variation tends to be correlated when the partials belong to the same source; (c the presence of an interfering coincident partial reduces the correlation; and (d such a reduction is proportional to the relative amplitude of the interfering partial. Besides the improved accuracy, the proposed technique has other advantages over its predecessors: it works properly even if the sources have the same fundamental frequency, it is able to estimate the first partial (fundamental, which is not possible using the conventional interpolation method, it can estimate the amplitude of a given partial even if its neighbors suffer intense interference from other sources, it works properly under noisy conditions, and it is immune to intraframe permutation errors. Experimental results show that the strategy clearly outperforms the interpolation approach.

  20. Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Yuan-Chuan [Washington Univ., St. Louis, MO (United States). School of Medicine

    2016-09-30

    The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11C to study carbon assimilation in biofuel plants.

  1. PET with a coincidence gamma camera: results in selected oncological questions

    International Nuclear Information System (INIS)

    Lauer, I.; Haase, A; Adam, S.; Prueter, I.; Richter, E.; Baehre, M.

    2001-01-01

    Since early 1997, about 1660 investigations with coincidence gamma camera PET (CGC-PET) have been performed in our department, mostly undertaken for oncological questions. Based on these data, several retrospective and prospective studies were performed. In the following, the results in CUP (cancer of unknown primary) syndrome, melanoma and malignant lymphoma are presented. Methods: CGC-PET was performed after application of 250-350 MBq [ 18 F]FDG using a coincidence double head gamma camera with 19 mm Nal cristal. CUP-Syndrome: After completing conventional diagnostic procedures, 32 patients have been examined in a prospective study, including 25 patients with recently detected CUP and 7 patients undergoing restaging after therapy. Localization of the primary tumor was successful in 12 (38%) cases. Melanoma: We evaluated 50 studies in 41 patients suffering from melanoma, retrospectively. CGC-PET showed a sensitivity of 76%, and a specificity of 94%. In comparison to conventional diagnostic methods, CGC-PET delineated important additional information in 16%. CGC-PET was superior to morphological diagnostic tools in the differentiation between residual scar tissue and active tumor following immunochemotherapy. Malignant lymphoma: 29 CGC-PET in 29 patients were performed for staging of malignant lymphoma, sensitivity was 86% versus 88% for CT. Overall CGC-PET showed additional information to conventional diagnostic methods, but revealed problems in detecting small infiltrations of organs. In restaging malignant melanoma (26 patients, 33 studies), specificity of CGC-PET was superior to conventional diagnostics (92% versus 35%). (orig.) [de

  2. Total variation-based method for radar coincidence imaging with model mismatch for extended target

    Science.gov (United States)

    Cao, Kaicheng; Zhou, Xiaoli; Cheng, Yongqiang; Fan, Bo; Qin, Yuliang

    2017-11-01

    Originating from traditional optical coincidence imaging, radar coincidence imaging (RCI) is a staring/forward-looking imaging technique. In RCI, the reference matrix must be computed precisely to reconstruct the image as preferred; unfortunately, such precision is almost impossible due to the existence of model mismatch in practical applications. Although some conventional sparse recovery algorithms are proposed to solve the model-mismatch problem, they are inapplicable to nonsparse targets. We therefore sought to derive the signal model of RCI with model mismatch by replacing the sparsity constraint item with total variation (TV) regularization in the sparse total least squares optimization problem; in this manner, we obtain the objective function of RCI with model mismatch for an extended target. A more robust and efficient algorithm called TV-TLS is proposed, in which the objective function is divided into two parts and the perturbation matrix and scattering coefficients are updated alternately. Moreover, due to the ability of TV regularization to recover sparse signal or image with sparse gradient, TV-TLS method is also applicable to sparse recovering. Results of numerical experiments demonstrate that, for uniform extended targets, sparse targets, and real extended targets, the algorithm can achieve preferred imaging performance both in suppressing noise and in adapting to model mismatch.

  3. Cosmology of a FLRW 3-brane, late-time cosmic acceleration, and the cosmic coincidence

    CERN Document Server

    Doolin, Ciaran

    2013-01-01

    A late epoch cosmic acceleration may be naturally entangled with cosmic coincidence - the observation that at the onset of acceleration the vacuum energy density fraction nearly coincides with the matter density fraction. In this letter we show that this is indeed the case with the cosmology of a Friedmann-Lama\\^itre-Robertson-Walker (FLRW) 3-brane in a 5-dimensional anti-de Sitter spacetime. We derive the 4-dimensional effective action on a FLRW 3-brane, which helps define a general reduction formula, namely $M_P^{2}=\\rho_{b}/|\\Lambda_5|$, where $M_{P}$ is the effective Planck mass, $\\Lambda_5$ is the 5-dimensional cosmological constant and $\\rho_b$ is the sum of the 3-brane tension $V$ and the matter density $\\rho$. The behavior of the background solution is consistent with the results based on the form of the 4D effective potential. Although the range of variation in $\\rho_{b}$ is strongly constrained, the Big Bang Nucleosynthesis bound on the time variation of the renormalised Newton constant $G_N = (8\\pi...

  4. Determination of the absolute activity by the coincidences 4πβ-γ method

    International Nuclear Information System (INIS)

    Urcelay Silva, A.J.

    1975-01-01

    The 4π beta-gamma coincidence method for absolute determination of activities is extremely important in the production of high-precision radioactive sources. By means of this method it is possible to obtain absolute measurements of decay to within 0.1%. Thanks to the high efficiency of the 4π counter, most of the corrections required - background, random coincidences, dead time, decay scheme and detector efficiency - are small. The paper describes the experimental set-up showing the pulses in the two branches of the system, together with the conditions under which the 4πbeta flux detector functions. To determine whether the system was functioning satisfactorily, the activity of four cobalt-60 standards (supplied by the International Bureau of Weights and Measures based at Sevres in France) was determined and the differences obtained were less than 0.5% with respect to the certificates accompanying the sources. Alterations to the flux detector are suggested so that higher accuracy may be obtained. (author)

  5. Topologically associating domains are ancient features that coincide with Metazoan clusters of extreme noncoding conservation.

    Science.gov (United States)

    Harmston, Nathan; Ing-Simmons, Elizabeth; Tan, Ge; Perry, Malcolm; Merkenschlager, Matthias; Lenhard, Boris

    2017-09-05

    Developmental genes in metazoan genomes are surrounded by dense clusters of conserved noncoding elements (CNEs). CNEs exhibit unexplained extreme levels of sequence conservation, with many acting as developmental long-range enhancers. Clusters of CNEs define the span of regulatory inputs for many important developmental regulators and have been described previously as genomic regulatory blocks (GRBs). Their function and distribution around important regulatory genes raises the question of how they relate to 3D conformation of these loci. Here, we show that clusters of CNEs strongly coincide with topological organisation, predicting the boundaries of hundreds of topologically associating domains (TADs) in human and Drosophila. The set of TADs that are associated with high levels of noncoding conservation exhibit distinct properties compared to TADs devoid of extreme noncoding conservation. The close correspondence between extreme noncoding conservation and TADs suggests that these TADs are ancient, revealing a regulatory architecture conserved over hundreds of millions of years.Metazoan genomes contain many clusters of conserved noncoding elements. Here, the authors provide evidence that these clusters coincide with distinct topologically associating domains in humans and Drosophila, revealing a conserved regulatory genomic architecture.

  6. Investigating the γ decay of 65Ni from particle-γ coincidence data

    Science.gov (United States)

    Campo, L. Crespo; Larsen, A. C.; Garrote, F. L. Bello; Eriksen, T. K.; Giacoppo, F.; Görgen, A.; Guttormsen, M.; Klintefjord, M.; Renstrøm, T.; Sahin, E.; Siem, S.; Tornyi, T. G.; Tveten, G. M.

    2017-07-01

    The γ decay of 65Ni has been studied from particle-γ coincidence data on the 64Ni(d ,p γ )65Ni reaction. γ -ray spectra at excitation energies below Ex≈2 MeV have been studied and compared with previous measurements. Coincidences corresponding to Ex≈4.4 -6.1 MeV have been used to constrain the shape of the nuclear level density and γ -strength function of 65Ni by means of the Oslo method. The experimental γ -strength function presents an enhancement at γ energies below Eγ≈3 MeV . In addition, a resonance-like structure centered at Eγ≈4.6 MeV is seen together with accumulated strength at Eγ≈2.6 -3.6 MeV . The obtained results contribute to the systematic study of γ decay in the Ni isotopes, which is of great interest for the understanding of both single-particle and collective nuclear structure phenomena.

  7. A new MCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

    International Nuclear Information System (INIS)

    Evans, Louise G.; Schear, Melissa A.; Hendricks, John S.; Swinhoe, Martyn T.; Tobin, Stephen J.; Croft, Stephen

    2010-01-01

    The existing MCNPX(trademark) PTRAC coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the isotopes that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and isotope). Here, the power of this tool is demonstrated using a detector design that has been developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile isotopes of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

  8. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system

    International Nuclear Information System (INIS)

    Carlos, J. E. de; Granados, C. E.

    1972-01-01

    In 4π β-γ coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between theβ--and γ-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs

  9. Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, Aruna; Ganguly, Rumpa [Dept. of Diagnosis and Health Promotion, Division of Oral and Maxillofacial Radiology, Tufts University School of Dental Medicine, Boston (United States); Soroushian, Sheila [Dept. of Orthodontics, Howard University College of Dentistry, Washington, DC(United States)

    2013-12-15

    This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, 'With CCAP' and 'Without CCAP', there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

  10. Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

    International Nuclear Information System (INIS)

    Ramesh, Aruna; Ganguly, Rumpa; Soroushian, Sheila

    2013-01-01

    This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, 'With CCAP' and 'Without CCAP', there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

  11. Exploring short-GRB afterglow parameter space for observations in coincidence with gravitational waves

    Science.gov (United States)

    Saleem, M.; Resmi, L.; Misra, Kuntal; Pai, Archana; Arun, K. G.

    2018-03-01

    Short duration Gamma Ray Bursts (SGRB) and their afterglows are among the most promising electromagnetic (EM) counterparts of Neutron Star (NS) mergers. The afterglow emission is broad-band, visible across the entire electromagnetic window from γ-ray to radio frequencies. The flux evolution in these frequencies is sensitive to the multidimensional afterglow physical parameter space. Observations of gravitational wave (GW) from BNS mergers in spatial and temporal coincidence with SGRB and associated afterglows can provide valuable constraints on afterglow physics. We run simulations of GW-detected BNS events and assuming that all of them are associated with a GRB jet which also produces an afterglow, investigate how detections or non-detections in X-ray, optical and radio frequencies can be influenced by the parameter space. We narrow down the regions of afterglow parameter space for a uniform top-hat jet model, which would result in different detection scenarios. We list inferences which can be drawn on the physics of GRB afterglows from multimessenger astronomy with coincident GW-EM observations.

  12. Photoelectron-Auger electron coincidence spectroscopy of free molecules: New experiments

    International Nuclear Information System (INIS)

    Ulrich, Volker; Barth, Silko; Lischke, Toralf; Joshi, Sanjeev; Arion, Tiberiu; Mucke, Melanie; Foerstel, Marko; Bradshaw, Alex M.; Hergenhahn, Uwe

    2011-01-01

    Photoelectron-Auger electron coincidence spectroscopy probes the dicationic states produced by Auger decay following the photoionization of core or inner valence levels in atoms, molecules or clusters. Moreover, the technique provides valuable insight into the dynamics of core hole decay. This paper serves the dual purpose of demonstrating the additional information obtained by this technique compared to Auger spectroscopy alone as well as of describing the new IPP/FHI apparatus at the BESSY II synchrotron radiation source. The distinguishing feature of the latter is the capability to record both the photoelectron and Auger electron with good energy and angle resolution, for which purpose a large hemispherical electrostatic analyser is combined with several linear time-of-flight spectrometers. New results are reported for the K-shell photoionization of oxygen (O 2 ) and the subsequent KVV Auger decay. Calculations in the literature for non-coincident O 2 Auger spectra are found to be in moderately good agreement with the new data.

  13. Unique Coincidence and Fixed Point Theorem for g-Weakly C-Contractive Mappings in Partial Metric Spaces

    Directory of Open Access Journals (Sweden)

    Saud M. Alsulami

    2014-01-01

    Full Text Available We prove that every map satisfying the g-weakly C-contractive inequality in partial metric space has a unique coincidence point. Our results generalize several well-known existing results in the literature.

  14. Multiple sclerosis

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Kuehn, A.L.; Backens, M.; Papanagiotou, P.; Shariat, K.; Kostopoulos, P.

    2008-01-01

    Multiple sclerosis is the most common chronic inflammatory disease of myelin with interspersed lesions in the white matter of the central nervous system. Magnetic resonance imaging (MRI) plays a key role in the diagnosis and monitoring of white matter diseases. This article focuses on key findings in multiple sclerosis as detected by MRI. (orig.) [de

  15. Coincidence and coherent data analysis methods for gravitational wave bursts in a network of interferometric detectors

    International Nuclear Information System (INIS)

    Arnaud, Nicolas; Barsuglia, Matteo; Bizouard, Marie-Anne; Brisson, Violette; Cavalier, Fabien; Davier, Michel; Hello, Patrice; Kreckelbergh, Stephane; Porter, Edward K.

    2003-01-01

    Network data analysis methods are the only way to properly separate real gravitational wave (GW) transient events from detector noise. They can be divided into two generic classes: the coincidence method and the coherent analysis. The former uses lists of selected events provided by each interferometer belonging to the network and tries to correlate them in time to identify a physical signal. Instead of this binary treatment of detector outputs (signal present or absent), the latter method involves first the merging of the interferometer data and looks for a common pattern, consistent with an assumed GW waveform and a given source location in the sky. The thresholds are only applied later, to validate or not the hypothesis made. As coherent algorithms use more complete information than coincidence methods, they are expected to provide better detection performances, but at a higher computational cost. An efficient filter must yield a good compromise between a low false alarm rate (hence triggering on data at a manageable rate) and a high detection efficiency. Therefore, the comparison of the two approaches is achieved using so-called receiving operating characteristics (ROC), giving the relationship between the false alarm rate and the detection efficiency for a given method. This paper investigates this question via Monte Carlo simulations, using the network model developed in a previous article. Its main conclusions are the following. First, a three-interferometer network such as Virgo-LIGO is found to be too small to reach good detection efficiencies at low false alarm rates: larger configurations are suitable to reach a confidence level high enough to validate as true GW a detected event. In addition, an efficient network must contain interferometers with comparable sensitivities: studying the three-interferometer LIGO network shows that the 2-km interferometer with half sensitivity leads to a strong reduction of performances as compared to a network of three

  16. γγ-coincidence in the neutron rich nucleus 25F

    International Nuclear Information System (INIS)

    Vajta, Zs.; Sohler, D.; Dombradi, Zs.; Azaiez, F.; Belleguic, M.; Brown, B.A.; Becker, F.

    2012-01-01

    Complete text of publication follows. The 25 F isotope, having a valence proton in addition to the doubly closed shell 24 O core, is expected to have a rather simple structure: its energy spectrum can be described as a few single proton states coupled to the ground and excited states of the neighboring oxygen nucleus, 24 O. However, states arising from cross shell excitations may also be present. According to theoretical calculations intruder states may appear in 25 F somewhat above the neutron separation energy. To see if any of these states is bound the structure of 25 F was studied at GANIL by in-beam γ-spectroscopic technique in the double step fragmentation reaction. In the experiment the primary beam of 36 S delivered by the two GANIL cyclotrons at an energy of 77.5 MeVA and an intensity of 400 pnA hit a carbon target of 348 mg/cm 2 thickness placed in the SISSI device. The produced nuclei were selected through the Alpha spectrometer. The secondary beam was mainly composed of 24 F, 25,26 Ne, 27,28 Na and 29,30 Mg. The fragments produced by reactions of the secondary beam on an 'active' target made of a plastic scintillator sandwiched by two carbon foils were collected and identified at the focal plane of the SPEG spectrometer by the combined use of ΔE, E, TOF information. 74 BaF 2 scintillators surrounding the secondary target detected the γ rays from the fragments. The γ-spectra were corrected for the Doppler-shift caused by the large fragment velocity. As the detectors were closely packed, the γ rays could easily scatter from one detector to another. To decrease the background caused by the scattered particles, we used the array in anti-Compton mode. On the basis of the analysis of γ-ray spectrum taken for 25 F 6 γ lines are assigned to the studied nucleus between 750 and 4200 keV. To help the level scheme construction, γγ-coincidence matrices were created. Putting a gate on the most intense 1720-keV γ line, it was found to be in coincidence with

  17. Simultaneous, coincident 2-D ACAR and DBAR using segmented HPGe detectors incorporating sub-pixel interpolation

    International Nuclear Information System (INIS)

    Williams, Christopher S; Burggraf, Larry W; Petrosky, James C; Oxley, Mark E; Adamson, Paul E

    2010-01-01

    A three-dimensional Positron Annihilation Spectrometry System (3D PASS) for determination of 3D electron-positron (e - -e + ) momentum densities by measuring coincident annihilation photons was designed, constructed and characterized. 3D PASS collects a single data set including correlated photon energies and coincident photon positions which are typically collected separately by two-dimensional angular correlation of annihilation radiation (2D ACAR) and two-detector coincident Doppler broadening of annihilation radiation (CDBAR) spectrometry. 3D PASS is composed of two position-sensitive, high-purity germanium (HPGe) double-sided strip detectors (DSSD(s)) linked together by a 32-channel, 50 MHz digital electronics suite. The DSSDs data were analyzed to determine location of photon detection events using an interpolation method to achieve a spatial resolution less than the 5-mm width of the DSSDs' charge collection strips. The interpolation method relies on measuring a figure-of-merit proportional to the area of the transient charges observed on both strips directly adjacent to the charge collection strip detecting the full charge deposited by the annihilation photon. This sub-pixel resolution, corresponding to the error associated with event location within a sub-pixel was measured for both DSSDs using the approach outlined in Williams et al [1] and was on the order of ± 0.20 mm (± one-standard deviation). As a result of the sub-pixel resolution, the distance between the DSSDs and material sample was reduced by a factor of five compared to what is typically required in 2D ACAR systems was necessary to achieve 0.5-mrad angular resolution. This reduction in the system's footprint decreases attenuation of the annihilation photons in the air between the material sample and the DSSDs and increases the solid angle between the sample and the DSSDs, ultimately resulting in higher system detection efficiency. 3D PASS was characterized in the same manner comparable to

  18. Application of coincidence Doppler broadening spectroscopy to polypropylene and polyethylene: taking into account the positronium formation

    Energy Technology Data Exchange (ETDEWEB)

    Djourelov, N.; Suzuki, T.; Yu, R.S.; Shantarovich, V.; Kondo, K

    2004-07-12

    The coincidence Doppler broadening (CDB) and positron annihilation lifetime (PAL) techniques were applied to study low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene (PP), and antioxidant containing polypropylene (PPA). It was demonstrated that the Doppler-broadened lines for LDPE and PPA could be decomposed into two components a narrow component due to positronium (Ps) annihilation and another broader one due to free positron annihilation. The determined Ps-component in the Doppler-broadened line was used to calculate the Ps-corrected CDB ratios for HDPE and PP to LDPE. Different ways to compare CDB ratios in polymers were discussed. During a long-term ({approx}500 h) positron-irradiation experiment at a low temperature (50 K), a significant enhancement of the carbonyl group concentration in PP was found by means of CDB technique, while the enhancement in HDPE was very slight.

  19. Coincidence system for absolute measuring of radionuclide activity using surface barrier detectors

    International Nuclear Information System (INIS)

    Koskinas, M.F.; Dias, M.S.

    1986-01-01

    A system for the standardization of alpha-gamma radionuclides has been developed at IPEN. Two surface barrier detectors are coupled to two thin-window NaI(Tl) crystals, suitable for low energy gamma ray detection. The performance of the system has been verified by means of the standardization of a Am-241 solution. The absolute activity has been obtained using the extrapolation method applied to the 4πα-γ coincidence technique. The alpha efficiency was varied by placing absorbers over the source or by changing the source to detector distance. The results were compared to those obtained by the linear extrapolation method, using a flow-gas 4π proportional counter. The agreement between the results were around 99.5%. (Author) [pt

  20. The underwater coincidence counter for plutonium measurements in mixed-oxide fuel assemblies manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Menlove, H.O.; Abhold, M.; Baker, M.; Pecos, J.

    1999-01-01

    This manual describes the Underwater Coincidence Counter (UWCC) that has been designed for the measurement of plutonium in mixed-oxide (MOX) fuel assemblies prior to irradiation. The UWCC uses high-efficiency 3 He neutron detectors to measure the spontaneous-fission and induced-fission rates in the fuel assembly. Measurements can be made on MOX fuel assemblies in air or underwater. The neutron counting rate is analyzed for singles, doubles, and triples time correlations to determine the 240 Pu effective mass per unit length of the fuel assembly. The system can verify the plutonium loading per unit length to a precision of less than 1% in a measurement time of 2 to 3 minutes. System design, components, performance tests, and operational characteristics are described in this manual

  1. Reduction of elevated IGF-1 levels in coincident amyotrophic lateral sclerosis and acromegaly

    Science.gov (United States)

    PEREIRA, ERLICK A. C.; TURNER, MARTIN R.; WASS, JOHN A. H.; TALBOT, KEVIN

    2011-01-01

    We report a patient presenting with ALS in whom acromegaly was later confirmed. Insulin-like growth factor-1 (IGF-1) has been tried in the treatment of ALS and despite equivocal results from clinical trials, efforts have continued to try to harness the significant positive effects on motor neuron growth observed in vitro and in survival of mouse models of the disease. One subsequent study has reported an association between higher circulating serum IGF-1 levels and longer disease duration in ALS patients. Concern therefore arose in our case that treatment of the acromegaly with a somatostatin analogue might adversely affect the natural course of his ALS through lowering of potentially beneficial IGF-1 levels. Through clinical observation and prognostic modelling we suggest that this concern was unfounded. The potential interaction of these two rarely coincident disorders in our patient is discussed. PMID:19634028

  2. γ-Particle coincidence technique for the study of nuclear reactions

    Energy Technology Data Exchange (ETDEWEB)

    Zagatto, V.A.B., E-mail: vinicius.zagatto@gmail.com [Instituto de Física da Universidade de São Paulo (Brazil); Oliveira, J.R.B.; Allegro, P.R.P.; Chamon, L.C.; Cybulska, E.W.; Medina, N.H.; Ribas, R.V.; Seale, W.A.; Silva, C.P.; Gasques, L.R. [Instituto de Física da Universidade de São Paulo (Brazil); Zahn, G.S.; Genezini, F.A.; Shorto, J.M.B. [Instituto de Pesquisas Energéticas e Nucleares (Brazil); Lubian, J.; Linares, R. [Instituto de Física da Universidade Federal Fluminense (Brazil); Toufen, D.L. [Instituto Federal de Educação, Ciência e Tecnologia (Brazil); Silveira, M.A.G. [Centro Universitário da FEI (Brazil); Rossi, E.S. [Centro Universitário FIEO – UNIFIEO (Brazil); Nobre, G.P. [Lawrence Livermore National Laboratory (United States)

    2014-06-01

    The Saci-Perere γ ray spectrometer (located at the Pelletron AcceleratorLaboratory – IFUSP) was employed to implement the γ-particle coincidence technique for the study of nuclear reaction mechanisms. For this, the {sup 18}O+{sup 110}Pd reaction has been studied in the beam energy range of 45–54 MeV. Several corrections to the data due to various effects (energy and angle integrations, beam spot size, γ detector finite size and the vacuum de-alignment) are small and well controlled. The aim of this work was to establish a proper method to analyze the data and identify the reaction mechanisms involved. To achieve this goal the inelastic scattering to the first excited state of {sup 110}Pd has been extracted and compared to coupled channel calculations using the São Paulo Potential (PSP), being reasonably well described by it.

  3. Molecular photoionisation using synchrotron radiation. Photoelectron photoion coincidence and circular dichroism

    CERN Document Server

    Garcia-Macias, G A

    2002-01-01

    The first ionisation potential of the CF sub 3 radical has been determined in this work from the appearance potential of the CF sub 3 sup + fragment, formed in the photofragmentation of CF sub 3 Br. In obtaining this value special care has been taken in removing the contributions from second order light and internal energy of the fragmenting parent ion. The resulting ionisation potential was found to be in very good agreement with a number of recent theoretical calculations. The valence photoelectron spectra of three monoterpenes such as limonene, carvone and camphor have been recorded along with their mass spectra taken in coincidence with energy selected photoelectrons, providing information about state selected parent ion fragmentation channels. A new photoelectron spectrometer based on the Alien box design has been studied by ray-tracing simulations. It will include a two dimensional position sensitive detector system consisting in two micro channel plates in a chevron stack and a delay-line anode to enco...

  4. A new reaction chamber for heavy ion, light particles - gamma ray coincidences

    International Nuclear Information System (INIS)

    Petrovici, M.; Simion, V.; Andronic, A.; Berceanu, I.; Buta, A.; Duma, M.; Moisa, D.; Pop, A.; Migneco, E.; Del Zoppo, A.; Bellia, G.

    1994-01-01

    Available as short communication only. In order to perform heavy ion, light particles -gamma ray coincidence measurements the experimental set-up DRACULA is foreseen to be connected with the gamma ray filter existing at LNS Catania. For this purpose a new reaction chamber was constructed. It consists of a spherical body (200 mm in diameter), an exit part toward the big ionization chamber, an entrance part having three beam pipes, a target holder part and an inspecting window. As one can see from the figure attached, the chamber gives the possibility to perform measurements at three different angles. Around the chamber a number of 13 big NaI(Tl) crystals and 4-6 Ge(Li) detectors hold by a special frame are foreseen to be installed. (Author) 1 Fig., 2 Refs

  5. Digital data recording system for the 4 πβ-γ coincidence apparatus

    International Nuclear Information System (INIS)

    Shaha, V.V.; Srivastava, P.K.

    1975-01-01

    The data recording system for the 4πβ-γ coincidence apparatus consists of three scalers, a timer, a day-clock, a print control unit and a Hewlett-Packard printer. The print control unit serves as an interface unit as well as generates necessary electronic commands for starting, scanning, recycling and actuating the printer. It also generates the run number and identification number. It has made the data recording and recycling completely automatic. The report describes the data recording system which has been in continuous use since March 1973. Brief description of the scalers, the timer, the day-clock and the printer is given. The print control unit is described and the working of the data handling, scanning and cycle counting sections is explained. (author)

  6. A coincidence-type ion-electron converter detector for low-energy protons

    International Nuclear Information System (INIS)

    Benka, O.; Weinzierl, P.; Dobrozemsky, R.; Stratowa, C.

    1981-04-01

    A coincidence type ion-electron converter detector has been developed and used - together with an electrostatic energy-analyser - for precision measurements of the energy distribution of recoil protons from free-neutron decay. The most important aspect of the development was, besides keeping the background below 0,2 counts/sec in the presence of a certain radiation background, to achieve a high and energy-independent counting probability for protons with energies between 100 and 1000 eV. With an acceleration voltage of about 25 kV and Al-foils (20 to 35 ug/cmsup2) as converter, we obtained counting efficiences of 70 to 85 percent. The design and performance of the detector system, employing six foils with different sensitive areas, are described and discussed in detail. (author)

  7. Frequent floods in the European Alps coincide with cooler periods of the past 2500 years.

    Science.gov (United States)

    Glur, Lukas; Wirth, Stefanie B; Büntgen, Ulf; Gilli, Adrian; Haug, Gerald H; Schär, Christoph; Beer, Jürg; Anselmetti, Flavio S

    2013-09-26

    Severe floods triggered by intense precipitation are among the most destructive natural hazards in Alpine environments, frequently causing large financial and societal damage. Potential enhanced flood occurrence due to global climate change would thus increase threat to settlements, infrastructure, and human lives in the affected regions. Yet, projections of intense precipitation exhibit major uncertainties and robust reconstructions of Alpine floods are limited to the instrumental and historical period. Here we present a 2500-year long flood reconstruction for the European Alps, based on dated sedimentary flood deposits from ten lakes in Switzerland. We show that periods with high flood frequency coincide with cool summer temperatures. This wet-cold synchronism suggests enhanced flood occurrence to be triggered by latitudinal shifts of Atlantic and Mediterranean storm tracks. This paleoclimatic perspective reveals natural analogues for varying climate conditions, and thus can contribute to a better understanding and improved projections of weather extremes under climate change.

  8. Application of coincidence Doppler broadening spectroscopy to polypropylene and polyethylene: taking into account the positronium formation

    Science.gov (United States)

    Djourelov, N.; Suzuki, T.; Yu, R. S.; Shantarovich, V.; Kondo, K.

    2004-07-01

    The coincidence Doppler broadening (CDB) and positron annihilation lifetime (PAL) techniques were applied to study low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene (PP), and antioxidant containing polypropylene (PPA). It was demonstrated that the Doppler-broadened lines for LDPE and PPA could be decomposed into two components a narrow component due to positronium (Ps) annihilation and another broader one due to free positron annihilation. The determined Ps-component in the Doppler-broadened line was used to calculate the Ps-corrected CDB ratios for HDPE and PP to LDPE. Different ways to compare CDB ratios in polymers were discussed. During a long-term (˜500 h) positron-irradiation experiment at a low temperature (50 K), a significant enhancement of the carbonyl group concentration in PP was found by means of CDB technique, while the enhancement in HDPE was very slight.

  9. Coincident Auger electron and recoil ion momentum spectroscopy for low-energy ion-atom collisions

    Energy Technology Data Exchange (ETDEWEB)

    Laurent, G. E-mail: glaurent@ganil.fr; Tarisien, M.; Flechard, X.; Jardin, P.; Guillaume, L.; Sobocinski, P.; Adoui, L.; Bordenave-Montesquieu, A.; Bordenave-Montesquieu, D.; Chesnel, J.-Y.; Fremont, F.; Hennecart, D.; Lienard, E.; Maunoury, L.; Moretto-Capelle, P.; Cassimi, A

    2003-05-01

    The recoil ion momentum spectroscopy (RIMS) method combined with the detection of Auger electrons has been used successfully to analyse double electron capture following O{sup 6+} + He collisions at low impact velocities. Although RIMS and Auger spectroscopies are known to be efficient tools to obtain details on the primary processes occurring during the collision, the conjunction of both techniques provides new insights on the electron capture process. In the present experiment, triple coincidence detection of the scattered projectile, the target recoil ion and the Auger electron allows for a precise identification of the doubly excited states O{sup 4+} (1s{sup 2}nln{sup '}l{sup '}) populated after double electron-capture events.

  10. The Anti-Coincidence Detector for the GLAST Large Area Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Moiseev, A.A.; Hartman, R.C.; Ormes, J.F.; Thompson, D.J.; Amato, M.J.; Johnson, T.E.; Segal, K.N.; Sheppard, D.A.

    2007-03-23

    This paper describes the design, fabrication and testing of the Anti-Coincidence Detector (ACD) for the Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT). The ACD is LAT's first-level defense against the charged cosmic ray background that outnumbers the gamma rays by 3-5 orders of magnitude. The ACD covers the top and 4 sides of the LAT tracking detector, requiring a total active area of {approx}8.3 square meters. The ACD detector utilizes plastic scintillator tiles with wave-length shifting fiber readout. In order to suppress self-veto by shower particles at high gamma-ray energies, the ACD is segmented into 89 tiles of different sizes. The overall ACD efficiency for detection of singly charged relativistic particles entering the tracking detector from the top or sides of the LAT exceeds the required 0.9997.

  11. Subducting slab ultra-slow velocity layer coincident with silent earthquakes in southern Mexico.

    Science.gov (United States)

    Song, Teh-Ru Alex; Helmberger, Donald V; Brudzinski, Michael R; Clayton, Robert W; Davis, Paul; Pérez-Campos, Xyoli; Singh, Shri K

    2009-04-24

    Great earthquakes have repeatedly occurred on the plate interface in a few shallow-dipping subduction zones where the subducting and overriding plates are strongly locked. Silent earthquakes (or slow slip events) were recently discovered at the down-dip extension of the locked zone and interact with the earthquake cycle. Here, we show that locally observed converted SP arrivals and teleseismic underside reflections that sample the top of the subducting plate in southern Mexico reveal that the ultra-slow velocity layer (USL) varies spatially (3 to 5 kilometers, with an S-wave velocity of approximately 2.0 to 2.7 kilometers per second). Most slow slip patches coincide with the presence of the USL, and they are bounded by the absence of the USL. The extent of the USL delineates the zone of transitional frictional behavior.

  12. Upgrading DRACULA setup to be used for light products - fission fragments coincidence measurements

    International Nuclear Information System (INIS)

    Simion, V.; Petrovici, M.; Pop, A.; Berceanu, I.; Duma, M.; Moisa, D.; Pagano, A.; Geraci, E.

    1999-01-01

    At low bombarding energy (E/A 238 U give rise to a number of fission processes, all leading to very similar fission products. Therefore, in order to understand the fission processes in this energy domain it is of interest to determine the amount of fission occurring after a peripheral interaction relative to that originating from compound nucleus formation. Although the detection of a projectile residue (PLF) in coincidence with the fission fragments is a very promising probe for the macroscopic features of the mechanism of induced fission, at incident energies in the vicinity of the Coulomb barrier (E/A 2 cross section area uses the phoswich technique by coupling a thin fast NE102A plastic scintillator to a 10 cm long BaF 2 crystal of hexagonal section. The BaF 2 crystal detectors have been successfully used in modular multielement detector ARGOS in the context of GANCT and HOTCT researches at LNS. The light response of the phoswich configuration as a function of the plastic thickness and of the energy and charge of the incident ion has been studied at Tandem energies. Both arrays will be placed in separate vacuum chambers attached to the remaining large angular opening windows of the reaction chamber. By rotating the whole device the fission fragment detection arrays will cover a range of 96 angle in the horizontal plane. The main advantage of this setup is that it allows to perform continuous measurements in energy and angle of the reaction products. The geometry of the whole device has been tested by Monte Carlo calculations using the code ELPHIC. The coincidence condition is completely fulfilled for the first two positions of the setup and partially for the third one. Measurements are intended to be performed at the SMP Tandem from LNS-Catania using light beams ( 16 O, 19 F, 20 Ne, 32 S) at ∼ 6 MeV/A on high fissility parameter targets. (authors)

  13. Analysis of Coincident HICO and Airborne Hyperspectral Images Over Lake Erie Western Basin HABs

    Science.gov (United States)

    Cline, Michael T., Jr.

    Harmful algal blooms (HABs) produce waterborne toxins that pose a significant threat to people, livestock, and wildlife. Nearly 40 million people in both Canada and the U.S. depend on Great Lakes water. In the summer of 2014, in the Lake Erie Western Basin, an HAB of the cyanobacteria Microcystis was so severe that a do-not-drink advisory was in effect for the greater Toledo area, Ohio. This advisory applied to the water supply to over 400,000 people from a single water intake. Bloom intensity, composition, and spatial variability were investigated by comparing coincidental hyperspectral data from NASA's HICO, and NASA GRC's HSI airborne sensor, with on-lake ASD radiometer measurements and in situ water quality testing as ground reference data. Coincident data sets were obtained with HICO only on one day in 2014, however all other datasets coincide four times in 2015. Remote sensing data were atmospherically corrected using the empirical line method, utilizing dark reference spectra from a nearby asphalt parking lot measured from ASD and HSI radiometers. Cyanobacteria Index (CI) images were created from processed images using the Wynne (2010) algorithm, previously used for MODIS and MERIS imagery. This algorithm-generated CI images provide reliable results for both ground level (R2=0.921), airborne (R2=0.7981), and satellite imagery (R2=0.7794) for seven sampling points. The ability to robustly atmospherically correct and generate useful CI maps from airborne and satellite sensors can provide a time- and cost-effective method for HABs analysis. Timely processing of these high spatial and spectral resolution remote sensing data can aid in management of water intake resources. These results will help to improve methods leading to HABs mapping by testing different algal retrieval algorithms and atmospheric correction techniques using a three tiered hyperspectral sensor approach utilizing satellite, airborne, and ground level sensors, coupled with water quality

  14. Song pattern recognition in crickets based on a delay-line and coincidence-detector mechanism.

    Science.gov (United States)

    Hedwig, Berthold; Sarmiento-Ponce, Edith Julieta

    2017-05-31

    Acoustic communication requires filter mechanisms to process and recognize key features of the perceived signals. We analysed such a filter mechanism in field crickets ( Gryllus bimaculatus ), which communicate with species-specific repetitive patterns of sound pulses and chirps. A delay-line and coincidence-detection mechanism, in which each sound pulse has an impact on the processing of the following pulse, is implicated to underlie the recognition of the species-specific pulse pattern. Based on this concept, we hypothesized that altering the duration of a single pulse or inter-pulse interval in three-pulse chirps will lead to different behavioural responses. Phonotaxis was tested in female crickets walking on a trackball exposed to different sound paradigms. Changing the duration of either the first, second or third pulse of the chirps led to three different characteristic tuning curves. Long first pulses decreased the phonotactic response whereas phonotaxis remained strong when the third pulse was long. Chirps with three pulses of increasing duration of 5, 20 and 50 ms elicited phonotaxis, but the chirps were not attractive when played in reverse order. This demonstrates specific, pulse duration-dependent effects while sequences of pulses are processed. The data are in agreement with a mechanism in which processing of a sound pulse has an effect on the processing of the subsequent pulse, as outlined in the flow of activity in a delay-line and coincidence-detector circuit. Additionally our data reveal a substantial increase in the gain of phonotaxis, when the number of pulses of a chirp is increased from two to three. © 2017 The Authors.

  15. STDP allows close-to-optimal spatiotemporal spike pattern detection by single coincidence detector neurons.

    Science.gov (United States)

    Masquelier, Timothée

    2017-06-29

    Repeating spatiotemporal spike patterns exist and carry information. How this information is extracted by downstream neurons is unclear. Here we theoretically investigate to what extent a single cell could detect a given spike pattern and what the optimal parameters to do so are, in particular the membrane time constant τ. Using a leaky integrate-and-fire (LIF) neuron with homogeneous Poisson input, we computed this optimum analytically. We found that a relatively small τ (at most a few tens of ms) is usually optimal, even when the pattern is much longer. This is somewhat counter-intuitive as the resulting detector ignores most of the pattern, due to its fast memory decay. Next, we wondered if spike-timing-dependent plasticity (STDP) could enable a neuron to reach the theoretical optimum. We simulated a LIF equipped with additive STDP, and repeatedly exposed it to a given input spike pattern. As in previous studies, the LIF progressively became selective to the repeating pattern with no supervision, even when the pattern was embedded in Poisson activity. Here we show that, using certain STDP parameters, the resulting pattern detector is optimal. These mechanisms may explain how humans learn repeating sensory sequences. Long sequences could be recognized thanks to coincidence detectors working at a much shorter timescale. This is consistent with the fact that recognition is still possible if a sound sequence is compressed, played backward, or scrambled using 10-ms bins. Coincidence detection is a simple yet powerful mechanism, which could be the main function of neurons in the brain. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Using neutron angular anisotropy information to dynamically determine the ratio of the (α,n) rate to spontaneous fission rate for coincidence counting applications

    Science.gov (United States)

    Holewa, L.; Charlton, W.; Miller, E.; Pozzi, S.

    2013-02-01

    Typically, when neutron coincidence or multiplicity counting is performed, there are three unknowns: the sample mass, the leakage self-multiplication, and the ratio of the (α,n) rate of the source to the spontaneous fission rate. For a given counting time, the strength of the source or the detector efficiency must be sufficiently high for the singles, doubles, and triples count rates to represent statistically meaningful quantities. Often, the strength of the source and the allotted counting time are such that only the singles and doubles count rates are statistically meaningful. In this latter case, the ratio of (α,n) to the spontaneous fission must be estimated through some other means. With a simulated (α,n) rate, the two equations related to the singles and doubles count rates can be used to determine the sample mass. In order to determine the ratio of (α,n) to spontaneous fission rate of the source, the isotopic composition of the sample as well as the light element impurities inside the source must be known. Ideally, there would be a way to dynamically determine the (α,n) rate of the source from count rate information. In this paper, it is shown that the (α,n) rate of the source can be determined by using information about the ratio of the number of coincident neutrons at 180° to the number at 90°. By using this information, the three aforementioned unknowns can be dynamically determined through the sole use of singles and doubles count rates.

  17. Active neutron multiplicity counting of bulk uranium

    International Nuclear Information System (INIS)

    Ensslin, N.; Krick, M.S.; Langner, D.G.; Miller, M.C.

    1991-01-01

    This paper describes a new nondestructive assay technique being developed to assay bulk uranium containing kilogram quantities of 235 U. The new technique uses neutron multiplicity analysis of data collected with a coincidence counter outfitted with AmLi neutron sources. We have calculated the expected neutron multiplicity count rate and assay precision for this technique and will report on its expected performance as a function of detector design characteristics, 235 U sample mass, AmLi source strength, and source-to-sample coupling. 11 refs., 2 figs., 2 tabs

  18. Value of coincidence gamma camera PET for diagnosing head and neck tumors: functional imaging and image coregistration

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Hahn, K.

    2001-01-01

    54 patients suffering from head and neck tumors (30 m, 24 f, age: 32-67 years) were examined using dedicated PET and coincidence gamma camera PET after injection of 185-350 MBq [ 18 F]FDG. Examinations were carried out on the dedicated PET first (Siemens ECAT Exact HR+) followed by a scan on the coincidence gamma camera PET (Picker Prism 2000 XP-PCD, Marconi Axis g-PET 2 AZ). Dedicated PET was acquired in 3D mode, coincidence gamma camera PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and coincidence gamma camera PET. All patients received a CT scan in multislice technique (Siemens Somatom Plus 4, Marconi MX 8000). Image coregistration was performed on an Odyssey workstation (Marconi). All findings have been verified by the gold standard histology or in case of negative histology by follow-up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using coincidence gamma camera PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with coincidence gamma camera PET and in 15/18 with CT. False-positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and hybrid PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastatic lesions were seen with dedicated PET and with coincidence gamma camera PET elsewhere in the body (lung: n = 7, bone: n = 3, liver: n = 1). Additional malignant disease other than the head and neck tumor was found in 4 patients. (orig.) [de

  19. Multiple myeloma.

    LENUS (Irish Health Repository)

    Collins, Conor D

    2012-02-01

    Advances in the imaging and treatment of multiple myeloma have occurred over the past decade. This article summarises the current status and highlights how an understanding of both is necessary for optimum management.

  20. Multiple Sclerosis

    Science.gov (United States)

    ... read or download the National Academies/Institute of Medicine report, go to: " Multiple Sclerosis: Current Status and Strategies for the Future ." Information from the National Library of Medicine’s MedlinePlus ...

  1. Performance of coincidence imaging with long-lived positron emitters as an alternative to dedicated PET and SPECT

    Science.gov (United States)

    Sandström, Mattias; Tolmachev, Vladimir; Kairemo, Kalevi; Lundqvist, Hans; Lubberink, Mark

    2004-12-01

    An important application of quantitative imaging in nuclear medicine is the estimation of absorbed doses in radionuclide therapy. Depending on the radionuclide used for therapy, quantitative imaging of the kinetics of the therapeutic radiopharmaceutical could be done using planar imaging, SPECT or PET. Since many nuclear medicine departments have a gamma camera system that is also suitable for coincidence imaging, the performance of these systems with respect to quantitative imaging of PET isotopes that could be of use in radionuclide dosimetry is of interest. We investigated the performance of a gamma camera with coincidence imaging capabilities with 99mTc, 111In, 18F and 76Br and a dedicated PET system with 18F and 76Br, using a single standard set of phantom measurements. Here, 76Br was taken as a typical example of prompt gamma-emitting PET isotopes that are applicable in radionuclide therapy dosimetry such as 86Y and 124I. Image quality measurements show comparable image contrasts for 76Br coincidence imaging and 111In SPECT. Although the spatial resolution of coincidence imaging is better than single photon imaging, the contrast obtained with 76Br is not better than that with 99mTc or 111In because of the prompt gamma involved. Additional improvements are necessary to allow for quantitative coincidence imaging of long-lived, prompt gamma producing positron emitters.

  2. Method and program for decay scheme reconstruction based on formal logical analysis of gamma-gamma coincidence matrix

    International Nuclear Information System (INIS)

    Adam, J.; Tsupko-Sitnikov, V.M.

    1996-01-01

    A new, rigorously substantiated approach to construction of decay schemes on the basis of γ-γ coincidence data is described. Complete decay modes (concrete cascades of transitions from excited to the ground-state of a nucleus excited in a decay or a reaction) and continuity regions in complete modes (regions of successive transitions) are isolated by logical operations with rows (columns) of a symmetrical coincidence matrix where rows (columns) correspond to energies of coinciding transitions and matrix elements are unities and zeros, depending on the presence or absence of the given coincidence. To reject false complete modes and continuity regions arising from incompleteness of the coincidence data and errors in them, energy selection is introduced for complete modes and continuity regions, which demands that total energy of their constituent transitions should be equal to total energy of some other complete modes and continuity regions and to the energies of singles. With the continuity regions found, it is possible to order transitions in the selected complete modes and to algorithmize matching of complete modes into a decay scheme. 10 refs., 3 figs

  3. Cocaine Promotes Coincidence Detection and Lowers Induction Threshold during Hebbian Associative Synaptic Potentiation in Prefrontal Cortex.

    Science.gov (United States)

    Ruan, Hongyu; Yao, Wei-Dong

    2017-01-25

    Addictive drugs usurp neural plasticity mechanisms that normally serve reward-related learning and memory, primarily by evoking changes in glutamatergic synaptic strength in the mesocorticolimbic dopamine circuitry. Here, we show that repeated cocaine exposure in vivo does not alter synaptic strength in the mouse prefrontal cortex during an early period of withdrawal, but instead modifies a Hebbian quantitative synaptic learning rule by broadening the temporal window and lowers the induction threshold for spike-timing-dependent LTP (t-LTP). After repeated, but not single, daily cocaine injections, t-LTP in layer V pyramidal neurons is induced at +30 ms, a normally ineffective timing interval for t-LTP induction in saline-exposed mice. This cocaine-induced, extended-timing t-LTP lasts for ∼1 week after terminating cocaine and is accompanied by an increased susceptibility to potentiation by fewer pre-post spike pairs, indicating a reduced t-LTP induction threshold. Basal synaptic strength and the maximal attainable t-LTP magnitude remain unchanged after cocaine exposure. We further show that the cocaine facilitation of t-LTP induction is caused by sensitized D1-cAMP/protein kinase A dopamine signaling in pyramidal neurons, which then pathologically recruits voltage-gated l-type Ca 2+ channels that synergize with GluN2A-containing NMDA receptors to drive t-LTP at extended timing. Our results illustrate a mechanism by which cocaine, acting on a key neuromodulation pathway, modifies the coincidence detection window during Hebbian plasticity to facilitate associative synaptic potentiation in prefrontal excitatory circuits. By modifying rules that govern activity-dependent synaptic plasticity, addictive drugs can derail the experience-driven neural circuit remodeling process important for executive control of reward and addiction. It is believed that addictive drugs often render an addict's brain reward system hypersensitive, leaving the individual more susceptible to

  4. [REPAIR OF THUMB PULP DEFECTS WITH SIDE ISLAND FLAP COINCIDING DORSAL BRANCH OF DIGITAL NERVE].

    Science.gov (United States)

    Yang, Huanyou; Wang, Bin; Lu, Aidong; Li, Ruiguo; Chen, Chao; Ma, Tiepeng

    2014-07-01

    To explore the effectiveness of the side island flap coinciding dorsal branch of the digital. nerve for repairing thumb pulp defects. Between May 2008 and July 2012, 36 cases of thumb pulp defects were treated with the side island flap coinciding dorsal branch of the digital nerve. There were 26 males and 10 females, aged 21-51 years (mean, 32.4 years). The injury causes included electric saw injury in 14 cases, punchpress injury in 8 cases, machine twist injury in 5 cases, door crushing injury in 5 cases, and glass cutting injury in 4 cases. The left hand was involved in 12 cases and the right hand in 24 cases. Combined injuries included tendon and bone exposure in all cases, fracture of the distal phalanx in 3 cases, and nail bed lacerations in 2 cases. The defect size ranged from 1.4 cm x 1.2 cm to 2.5 cm x 2.1 cm; and the flap size ranged from 1.8 cm x 1.4 cm to 3.0 cm x 2.5 cm. Two flaps with distal skin flap tension blisters and skin scabbing, which were cured after dressing changes; the wound healed by first intension in the other 34 cases. The skin grafts at donor site survived, and primary healing of incision was obtained. The patients were followed up 3-15 months (mean, 8 months). The appearance and function restored well. Two-point discrimination of the flap was 5.2 mm on average (range, 4-8 mm) at last follow-up. The finger joint had no stiff. According to the upper extremity function evaluation criteria issued by the Hand Surgery Society of Chinese Medical Association, the sensation was S4 in 33 and S3+ in 3 cases. No ectopic feeling was observed. The extension and flexion activity of fingers at donor site was normal, the sensation reached S4 with no atrophy of the finger. With constant anatomy, reliable blood supply, and safe operation, the anastomoses of the finger side island flap with dorsal branch of digital nerve is a better method to repair thumb pulp defects because it also effectively overcome the ectopic feeling with traditional methods and

  5. Search for Transient Gravitational Waves in Coincidence with Short-Duration Radio Transients During 2007-2013

    Science.gov (United States)

    Abbott, B. P.; Hughey, Brennan; Zanolin, Michele; Szczepanczyk, Marek; Gill, Kiranjyot; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; hide

    2016-01-01

    We present an archival search for transient gravitational-wave bursts in coincidence with 27 single-pulse triggers from Green Bank Telescope pulsar surveys, using the LIGO (Laser Interferometer Gravitational Wave Observatory), Virgo (Variability of Solar Irradiance and Gravity Oscillations) and GEO (German-UK Interferometric Detector) interferometer network. We also discuss a check for gravitational-wave signals in coincidence with Parkes fast radio bursts using similar methods. Data analyzed in these searches were collected between 2007 and 2013. Possible sources of emission of both short-duration radio signals and transient gravitational-wave emission include star quakes on neutron stars, binary coalescence of neutron stars, and cosmic string cusps. While no evidence for gravitational-wave emission in coincidence with these radio transients was found, the current analysis serves as a prototype for similar future searches using more sensitive second-generation interferometers.

  6. A First Search for Coincident Gravitational Waves and High Energy Neutrinos Using LIGO, Virgo and ANTARES Data from 2007

    Science.gov (United States)

    Adrian-Martinez, S.; Samarai, Al; Albert, A.; Andre, M.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M; Astraatmadja, T.; Aubert, J.-J.; hide

    2013-01-01

    We present the results of the first search for gravitational wave bursts associated with high energy neutrinos. Together, these messengers could reveal new, hidden sources that are not observed by conventional photon astronomy, particularly at high energy. Our search uses neutrinos detected by the underwater neutrino telescope ANTARES in its 5 line configuration during the period January - September 2007, which coincided with the fifth and first science runs of LIGO and Virgo, respectively. The LIGO-Virgo data were analysed for candidate gravitational-wave signals coincident in time and direction with the neutrino events. No significant coincident events were observed. We place limits on the density of joint high energy neutrino - gravitational wave emission events in the local universe, and compare them with densities of merger and core-collapse events.

  7. A first search for coincident gravitational waves and high energy neutrinos using LIGO, Virgo and ANTARES data from 2007

    Science.gov (United States)

    Adrián-Martínez, S.; Samarai, I. Al; Albert, A.; André, M.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Astraatmadja, T.; Aubert, J.-J.; Baret, B.; Basa, S.; Bertin, V.; Biagi, S.; Bigongiari, C.; Bogazzi, C.; Bou-Cabo, M.; Bouhou, B.; Bouwhuis, M. C.; Brunner, J.; Busto, J.; Capone, A.; Cârloganu, C.; Carr, J.; Cecchini, S.; Charif, Z.; Charvis, Ph.; Chiarusi, T.; Circella, M.; Coniglione, R.; Core, L.; Costantini, H.; Coyle, P.; Creusot, A.; Curtil, C.; De Bonis, G.; Decowski, M. P.; Dekeyser, I.; Deschamps, A.; Distefano, C.; Donzaud, C.; Dornic, D.; Dorosti, Q.; Drouhin, D.; Eberl, T.; Emanuele, U.; Enzenhöfer, A.; Ernenwein, J.-P.; Escoffier, S.; Fehn, K.; Fermani, P.; Ferri, M.; Ferry, S.; Flaminio, V.; Folger, F.; Fritsch, U.; Fuda, J.-L.; Galatà, S.; Gay, P.; Geyer, K.; Giacomelli, G.; Giordano, V.; Gómez-González, J. P.; Graf, K.; Guillard, G.; Hallewell, G.; Hamal, M.; van Haren, H.; Heijboer, A. J.; Hello, Y.; Hernández-Rey, J. J.; Herold, B.; Hößl, J.; Hsu, C. C.; de Jong, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Katz, U.; Kavatsyuk, O.; Kooijman, P.; Kopper, C.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lambard, G.; Larosa, G.; Lattuada, D.; Lefèvre, D.; Lim, G.; Lo Presti, D.; Loehner, H.; Loucatos, S.; Louis, F.; Mangano, S.; Marcelin, M.; Margiotta, A.; Martínez-Mora, J. A.; Martini, S.; Meli, A.; Montaruli, T.; Morganti, M.; Moscoso, L.; Motz, H.; Neff, M.; Nezri, E.; Palioselitis, D.; Păvălaş, G. E.; Payet, K.; Petrovic, J.; Piattelli, P.; Popa, V.; Pradier, T.; Presani, E.; Racca, C.; Reed, C.; Riccobene, G.; Richardt, C.; Richter, R.; Rivière, C.; Robert, A.; Roensch, K.; Rostovtsev, A.; Ruiz-Rivas, J.; Rujoiu, M.; Russo, G. V.; Samtleben, D. F. E.; Sánchez-Losa, A.; Sapienza, P.; Schmid, J.; Schnabel, J.; Schöck, F.; Schuller, J.-P.; Schüssler, F.; Seitz, T.; Shanidze, R.; Simeone, F.; Spies, A.; Spurio, M.; Steijger, J. J. M.; Stolarczyk, Th.; Taiuti, M.; Tamburini, C.; Trovato, A.; Vallage, B.; Vallée, C.; Van Elewyck, V.; Vecchi, M.; Vernin, P.; Visser, E.; Wagner, S.; Wijnker, G.; Wilms, J.; de Wolf, E.; Yepes, H.; Zaborov, D.; Zornoza, J. D.; Zúñiga, J.; Aasi, J.; Abadie, J.; Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M.; Accadia, T.; Acernese, F.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Ajith, P.; Allen, B.; Allocca, A.; Amador Ceron, E.; Amariutei, D.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Ast, S.; Aston, S. M.; Astone, P.; Atkinson, D.; Aufmuth, P.; Aulbert, C.; Aylott, B. E.; Babak, S.; Baker, P.; Ballardin, G.; Ballmer, S.; Bao, Y.; Barayoga, J. C. B.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barton, M. A.; Bartos, I.; Bassiri, R.; Bastarrika, M.; Basti, A.; Batch, J.; Bauchrowitz, J.; Bauer, Th. S.; Bebronne, M.; Beck, D.; Behnke, B.; Bejger, M.; Beker, M. G.; Bell, A. S.; Bell, C.; Belopolski, I.; Benacquista, M.; Berliner, J. M.; Bertolini, A.; Betzwieser, J.; Beveridge, N.; Beyersdorf, P. T.; Bhadbade, T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Biswas, R.; Bitossi, M.; Bizouard, M. A.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Bland, B.; Blom, M.; Bock, O.; Bodiya, T. P.; Bogan, C.; Bond, C.; Bondarescu, R.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, S.; Bosi, L.; Braccini, S.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Breyer, J.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Britzger, M.; Brooks, A. F.; Brown, D. A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Burguet–Castell, J.; Buskulic, D.; Buy, C.; Byer, R. L.; Cadonati, L.; Cagnoli, G.; Calloni, E.; Camp, J. B.; Campsie, P.; Cannon, K.; Canuel, B.; Cao, J.; Capano, C. D.; Carbognani, F.; Carbone, L.; Caride, S.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chalermsongsak, T.; Charlton, P.; Chassande-Mottin, E.; Chen, W.; Chen, X.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Chow, J.; Christensen, N.; Chua, S. S. Y.; Chung, C. T. Y.; Chung, S.; Ciani, G.; Clara, F.; Clark, D. E.; Clark, J. A.; Clayton, J. H.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colacino, C. N.; Colla, A.; Colombini, M.; Conte, A.; Conte, R.; Cook, D.; Corbitt, T. R.; Cordier, M.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M.; Coulon, J.-P.; Couvares, P.; Coward, D. M.; Cowart, M.; Coyne, D. C.; Creighton, J. D. E.; Creighton, T. D.; Cruise, A. M.; Cumming, A.; Cunningham, L.; Cuoco, E.; Cutler, R. M.; Dahl, K.; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dattilo, V.; Daudert, B.; Daveloza, H.; Davier, M.; Daw, E. J.; Day, R.; Dayanga, T.; De Rosa, R.; DeBra, D.; Debreczeni, G.; Degallaix, J.; Del Pozzo, W.; Dent, T.; Dergachev, V.; DeRosa, R.; Dhurandhar, S.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Emilio, M. Di Paolo; Di Virgilio, A.; Díaz, M.; Dietz, A.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorsher, S.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Dumas, J.-C.; Dwyer, S.; Eberle, T.; Edgar, M.; Edwards, M.; Effler, A.; Ehrens, P.; Endrőczi, G.; Engel, R.; Etzel, T.; Evans, K.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Farr, B. F.; Favata, M.; Fazi, D.; Fehrmann, H.; Feldbaum, D.; Ferrante, I.; Ferrini, F.; Fidecaro, F.; Finn, L. S.; Fiori, I.; Fisher, R. P.; Flaminio, R.; Foley, S.; Forsi, E.; Forte, L. A.; Fotopoulos, N.; Fournier, J.-D.; Franc, J.; Franco, S.; Frasca, S.; Frasconi, F.; Frede, M.; Frei, M. A.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Friedrich, D.; Fritschel, P.; Frolov, V. V.; Fujimoto, M.-K.; Fulda, P. J.; Fyffe, M.; Gair, J.; Galimberti, M.; Gammaitoni, L.; Garcia, J.; Garufi, F.; Gáspár, M. E.; Gelencser, G.; Gemme, G.; Genin, E.; Gennai, A.; Gergely, L. Á.; Ghosh, S.; Giaime, J. A.; Giampanis, S.; Giardina, K. D.; Giazotto, A.; Gil-Casanova, S.; Gill, C.; Gleason, J.; Goetz, E.; González, G.; Gorodetsky, M. L.; Goßler, S.; Gouaty, R.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Griffo, C.; Grote, H.; Grover, K.; Grunewald, S.; Guidi, G. M.; Guido, C.; Gupta, R.; Gustafson, E. K.; Gustafson, R.; Hallam, J. M.; Hammer, D.; Hammond, G.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Hartman, M. T.; Haughian, K.; Hayama, K.; Hayau, J.-F.; Heefner, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M. A.; Heng, I. S.; Heptonstall, A. W.; Herrera, V.; Heurs, M.; Hewitson, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Holt, K.; Holtrop, M.; Hong, T.; Hooper, S.; Hough, J.; Howell, E. J.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Izumi, K.; Jacobson, M.; James, E.; Jang, Y. J.; Jaranowski, P.; Jesse, E.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kasprzack, M.; Kasturi, R.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kaufman, K.; Kawabe, K.; Kawamura, S.; Kawazoe, F.; Keitel, D.; Kelley, D.; Kells, W.; Keppel, D. G.; Keresztes, Z.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, B. K.; Kim, C.; Kim, H.; Kim, K.; Kim, N.; Kim, Y. M.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Kokeyama, K.; Kondrashov, V.; Koranda, S.; Korth, W. Z.; Kowalska, I.; Kozak, D.; Kringel, V.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kurdyumov, R.; Kwee, P.; Lam, P. K.; Landry, M.; Langley, A.; Lantz, B.; Lastzka, N.; Lawrie, C.; Lazzarini, A.; Le Roux, A.; Leaci, P.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Leong, J. R.; Leonor, I.; Leroy, N.; Letendre, N.; Lhuillier, V.; Li, J.; Li, T. G. F.; Lindquist, P. E.; Litvine, V.; Liu, Y.; Liu, Z.; Lockerbie, N. A.; Lodhia, D.; Logue, J.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Lubinski, M.; Lück, H.; Lundgren, A. P.; Macarthur, J.; Macdonald, E.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Mageswaran, M.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandel, I.; Mandic, V.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Marque, J.; Martelli, F.; Martin, I. W.; Martin, R. M.; Marx, J. N.; Mason, K.; Masserot, A.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McIver, J.; Meadors, G. D.; Mehmet, M.; Meier, T.; Melatos, A.; Melissinos, A. C.; Mendell, G.; Menéndez, D. F.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyer, M. S.; Miao, H.; Michel, C.; Milano, L.; Miller, J.; Minenkov, Y.; Mingarelli, C. M. F.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Mohan, M.; Mohapatra, S. R. P.; Moraru, D.; Moreno, G.; Morgado, N.; Morgia, A.; Mori, T.; Morriss, S. R.; Mosca, S.; Mossavi, K.; Mours, B.; Mow–Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Müller-Ebhardt, H.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nash, T.; Naticchioni, L.; Necula, V.; Nelson, J.; Neri, I.; Newton, G.; Nguyen, T.; Nishizawa, A.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E.; Nuttall, L.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Oldenberg, R. G.; O'Reilly, B.; O'Shaughnessy, R.; Osthelder, C.; Ott, C. D.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Page, A.; Palladino, L.; Palomba, C.; Pan, Y.; Pankow, C.; Paoletti, F.; Paoletti, R.; Papa, M. A.; Parisi, M.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Pedraza, M.; Penn, S.; Perreca, A.; Persichetti, G.; Phelps, M.; Pichot, M.; Pickenpack, M.; Piergiovanni, F.; Pierro, V.; Pihlaja, M.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Pletsch, H. J.; Plissi, M. V.; Poggiani, R.; Pöld, J.; Postiglione, F.; Poux, C.; Prato, M.; Predoi, V.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Quetschke, V.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Rakhmanov, M.; Ramet, C.; Rankins, B.; Rapagnani, P.; Raymond, V.; Re, V.; Reed, C. M.; Reed, T.; Regimbau, T.; Reid, S.; Reitze, D. H.; Ricci, F.; Riesen, R.; Riles, K.; Roberts, M.; Robertson, N. A.; Robinet, F.; Robinson, C.; Robinson, E. L.; Rocchi, A.; Roddy, S.; Rodriguez, C.; Rodruck, M.; Rolland, L.; Rollins, J. G.; Romano, J. D.; Romano, R.; Romie, J. H.; Rosińska, D.; Röver, C.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Salemi, F.; Sammut, L.; Sandberg, V.; Sankar, S.; Sannibale, V.; Santamaría, L.; Santiago-Prieto, I.; Santostasi, G.; Saracco, E.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R. L.; Schilling, R.; Schnabel, R.; Schofield, R. M. S.; Schulz, B.; Schutz, B. F.; Schwinberg, P.; Scott, J.; Scott, S. M.; Seifert, F.; Sellers, D.; Sentenac, D.; Sergeev, A.; Shaddock, D. A.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siemens, X.; Sigg, D.; Simakov, D.; Singer, A.; Singer, L.; Sintes, A. M.; Skelton, G. R.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M. R.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Somiya, K.; Sorazu, B.; Speirits, F. C.; Sperandio, L.; Stefszky, M.; Steinert, E.; Steinlechner, J.; Steinlechner, S.; Steplewski, S.; Stochino, A.; Stone, R.; Strain, K. A.; Strigin, S. E.; Stroeer, A. S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sung, M.; Susmithan, S.; Sutton, P. J.; Swinkels, B.; Szeifert, G.; Tacca, M.; Taffarello, L.; Talukder, D.; Tanner, D. B.; Tarabrin, S. P.; Taylor, R.; ter Braack, A. P. M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Thüring, A.; Titsler, C.; Tokmakov, K. V.; Tomlinson, C.; Toncelli, A.; Tonelli, M.; Torre, O.; Torres, C. V.; Torrie, C. I.; Tournefier, E.; Travasso, F.; Traylor, G.; Tse, M.; Ugolini, D.; Vahlbruch, H.; Vajente, G.; van den Brand, J. F. J.; Van Den Broeck, C.; van der Putten, S.; van Veggel, A. A.; Vass, S.; Vasuth, M.; Vaulin, R.; Vavoulidis, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Viceré, A.; Villar, A. E.; Vinet, J.-Y.; Vitale, S.; Vocca, H.; Vorvick, C.; Vyatchanin, S. P.; Wade, A.; Wade, L.; Wade, M.; Waldman, S. J.; Wallace, L.; Wan, Y.; Wang, M.; Wang, X.; Wanner, A.; Ward, R. L.; Was, M.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Wiesner, K.; Wilkinson, C.; Willems, P. A.; Williams, L.; Williams, R.; Willke, B.; Wimmer, M.; Winkelmann, L.; Winkler, W.; Wipf, C. C.; Wiseman, A. G.; Wittel, H.; Woan, G.; Wooley, R.; Worden, J.; Yablon, J.; Yakushin, I.; Yamamoto, H.; Yamamoto, K.; Yancey, C. C.; Yang, H.; Yeaton-Massey, D.; Yoshida, S.; Yvert, M.; Zadrożny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, F.; Zhang, L.; Zhao, C.; Zotov, N.; Zucker, M. E.; Zweizig, J.

    2013-06-01

    We present the results of the first search for gravitational wave bursts associated with high energy neutrinos. Together, these messengers could reveal new, hidden sources that are not observed by conventional photon astronomy, particularly at high energy. Our search uses neutrinos detected by the underwater neutrino telescope ANTARES in its 5 line configuration during the period January - September 2007, which coincided with the fifth and first science runs of LIGO and Virgo, respectively. The LIGO-Virgo data were analysed for candidate gravitational-wave signals coincident in time and direction with the neutrino events. No significant coincident events were observed. We place limits on the density of joint high energy neutrino - gravitational wave emission events in the local universe, and compare them with densities of merger and core-collapse events.

  8. Implementation of the active neutron Coincidence Collar for the verification of unirradiated PWR and BWR fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-01-01

    An active neutron interrogation technique has been developed for the measurement of the 235 U content in fresh fuel assemblies. The method employs an AmLi neutron source to induce fission reactions in the fuel assembly and coincidence counting of the resulting fission reaction neutrons. When no interrogation source is present, the passive neutron coincidence rate gives a measure of the 238 U by the spontaneous fission reactions. The system can be applied to the fissile content determination in fresh fuel assemblies for accountability, criticality control, and safeguards purposes. Field tests have been performed by International Atomic Energy Agency (IAEA) staff using the Coincidence Collar to verify the 235 U content in light-water-reactor fuel assemblies. The results gave an accuracy of 1 to 2% in the active mode ( 235 U) and 2 to 3% in the passive mode ( 238 U) under field conditions

  9. A new 4π(LS)-γ coincidence counter at NCBJ RC POLATOM with TDCR detector in the beta channel.

    Science.gov (United States)

    Ziemek, T; Jęczmieniowski, A; Cacko, D; Broda, R; Lech, E

    2016-03-01

    A new 4π(LS)-γ coincidence system (TDCRG) was built at the NCBJ RC POLATOM. The counter consists of a TDCR detector in the beta channel and scintillation detector with NaI(Tl) crystal in the gamma channel. The system is equipped with a digital board with FPGA, which records and analyses coincidences in the TDCR detector and coincidences between the beta and gamma channels. The characteristics of the system and a scheme of the FPGA implementation with behavioral simulation are given. The TDCRG counter was validated by activity measurements on (14)C and (60)Co solutions standardized in RC POLATOM using previously validated methods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Corrections for the effects of accidental coincidences, Compton scatter, and object size in positron emission mammography (PEM) imaging

    Energy Technology Data Exchange (ETDEWEB)

    Raymond Raylman; Stanislaw Majewski; Randolph Wojcik; Andrew Weisenberger; Brian Kross; Vladimir Popov

    2001-06-01

    Positron emission mammography (PEM) has begun to show promise as an effective method for the detection of breast lesions. Due to its utilization of tumor-avid radiopharmaceuticals labeled with positron-emitting radionuclides, this technique may be especially useful in imaging of women with radiodense or fibrocystic breasts. While the use of these radiotracers affords PEM unique capabilities, it also introduces some limitations. Specifically, acceptance of accidental and Compton-scattered coincidence events can decrease lesion detectability. The authors studied the effect of accidental coincidence events on PEM images produced by the presence of 18F-Fluorodeoxyglucose in the organs of a subject using an anthropomorphic phantom. A delayed-coincidence technique was tested as a method for correcting PEM images for the occurrence of accidental events. Also, a Compton scatter correction algorithm designed specifically for PEM was developed and tested using a compressed breast phantom.

  11. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, Egon; Stenager, E N; Knudsen, Lone

    1994-01-01

    In a cross-sectional study of 117 randomly selected patients (52 men, 65 women) with definite multiple sclerosis, it was found that 76 percent were married or cohabitant, 8 percent divorced. Social contacts remained unchanged for 70 percent, but outgoing social contacts were reduced for 45 percent......, need for structural changes in home and need for pension became greater with increasing physical handicap. No significant differences between gender were found. It is concluded that patients and relatives are under increased social strain, when multiple sclerosis progresses to a moderate handicap...

  12. Elliptic multiple zeta values and one-loop superstring amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Broedel, Johannes [Institut für Theoretische Physik, Eidgenössische Technische Hochschule Zürich,Wolfgang-Pauli-Strasse 27, 8093 Zürich (Switzerland); Mafra, Carlos R. [Department of Applied Mathematics and Theoretical Physics, University of Cambridge,Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Matthes, Nils [Fachbereich Mathematik, Universität Hamburg,Bundesstraße 55, 20146 Hamburg (Germany); Schlotterer, Oliver [Max-Planck-Institut für Gravitationsphysik, Albert-Einstein-Institut,Am Mühlenberg 1, 14476 Potsdam (Germany)

    2015-07-21

    We investigate iterated integrals on an elliptic curve, which are a natural genus-one generalization of multiple polylogarithms. These iterated integrals coincide with the multiple elliptic polylogarithms introduced by Brown and Levin when constrained to the real line. At unit argument they reduce to an elliptic analogue of multiple zeta values, whose network of relations we start to explore. A simple and natural application of this framework are one-loop scattering amplitudes in open superstring theory. In particular, elliptic multiple zeta values are a suitable language to express their low energy limit. Similar to the techniques available at tree-level, our formalism allows to completely automatize the calculation.

  13. "Islam" In the Anti-Multicultural Rhetoric of Western European Politicians and Anthropologists: Congruence or Coincidence?

    Directory of Open Access Journals (Sweden)

    Marko Pišev

    2016-02-01

    Full Text Available The recent rhetoric of the "end" or "failure" of multiculturalism in Europe and beyond came as no surprise to anthropologists. Moreover, the statements made by leading politicians of key European economies seem as though they are based on the decades old anthropological critique of the consequences of the failed implementation of multicultural policies in Europe and on the global level. It is as though the messages we have been getting over the course of the last few years – that multicultural policies are contraindicated, that they weaken the contacts between cultures, rob individuals of the right to change and chose their identities and strengthen intra-cultural mediators of power, with patriarchy, violence against women and children, leaving school, religious fundamentalism and even terrorism as main consequences – are being read by politicians from anthropological analyses of abuses of collective "cultural" rights. The paper considers the nature of this similarity between the discourse of politicians and anthropologists with a special emphasis on the status of "Islam" in them, and discusses whether it is congruence or mere coincidence of stances toward minorities, immigrants and cultural differences, as toward the regulations which were tasked with protecting this diversity as a fundamental European value which today, at least at the rhetorical level, seems to be fading.

  14. Cosmological dynamics of D-BIonic and DBI scalar field and coincidence problem of dark energy

    Science.gov (United States)

    Panpanich, Sirachak; Maeda, Kei-ichi; Mizuno, Shuntaro

    2017-05-01

    We study the cosmological dynamics of a D-BIonic and Dirac-Born-Infeld scalar field, which is coupled to matter fluid. For the exponential potential and the exponential couplings, we find a new analytic scaling solution yielding the accelerated expansion of the Universe. Since it is shown to be an attractor for some range of the coupling parameters, the density parameter of matter fluid can be the observed value, as in the coupled quintessence with a canonical scalar field. Contrary to the usual coupled quintessence, where the value of the matter coupling giving the observed density parameter is too large to satisfy the observational constraint from the cosmic microwave background, we show that the D-BIonic theory can give a similar solution with a much smaller value of matter coupling. As a result, together with the fact that the D-BIonic theory has a screening mechanism, the D-BIonic theory can solve the so-called coincidence problem as well as the dark energy problem.

  15. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence.

    Science.gov (United States)

    Liu, Bailing; Zhang, Fumin; Qu, Xinghua; Shi, Xiaojia

    2016-02-18

    Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration.

  16. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Directory of Open Access Journals (Sweden)

    Bailing Liu

    2016-02-01

    Full Text Available Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration.

  17. First satellite measurements of chemical changes in coincidence with sprite activity

    Science.gov (United States)

    Arnone, Enrico; São Sabbas, Fernanda; Kero, Antti; Soula, Serge; Carlotti, Massimo; Chanrion, Olivier; Dinelli, Bianca Maria; Papandrea, Enzo; Castelli, Elisa; Neubert, Torsten

    2010-05-01

    The last twenty years have seen the discovery of electric discharges in the Earth's atmosphere above thunderstorms, the so-called sprites and jets. It has been suggested that they impact the atmospheric chemistry and possibly affect the ozone layer through their repeated occurrence. Whereas theoretical studies and laboratory experiments suggest enhancement of such gasses as nitrogen oxides by up to hundreds of percent within sprites, a definitive detection of their chemical effects have to date been unsuccessful. In this paper, we report on the first measurements of atmospheric chemical perturbations recorded in coincidence with sprite activity. A striking event occurred on 25 August 2003 when the MIPAS spectrometer onboard the Envisat satellite recorded spectroscopic measurements soon after a sequence of 11 sprites observed above Corsica (France) by Eurosprite ground facilities (details of the convective system are discussed in a companion paper by São Sabbas et al.). The measurements show an enhancement of ambient nitrous oxide by 80% at 52 km altitude in the region above the parent thunderstorm. The recorded chemical changes imply sprites can exert significant modification of the atmospheric chemistry at a regional scale, confirming model and laboratory predictions of sprite-chemistry, and requiring a new estimate of their global impact. The results of the analysis and their implications are discussed.

  18. Imaging the electron transfer reaction of Ne2+ with Ar using position-sensitive coincidence spectroscopy

    International Nuclear Information System (INIS)

    Harper, Sarah M; Hu Wanping; Price, Stephen D

    2002-01-01

    A new experiment, employing position-sensitive detection coupled with time-of-flight mass spectrometry, has been used to investigate the single-electron transfer reaction between Ne 2+ and Ar by detecting the resulting pairs of singly charged ions in coincidence. The experimental technique allows the determination of the individual velocity vectors of the ionic products, in the centre-of-mass frame, for each reactive event detected. The experiments show that forward scattering dominates the reactivity, although a bimodal angular distribution is apparent. In addition, the spectra show that at laboratory frame collision energies from 4-14 eV the reactivity is dominated by Ne 2+ (2p 4 , 3 P) accepting an electron from an argon atom to form the ground state of Ne + together with an Ar + ion in an excited electronic level, predominantly arising from the Ar + (3s 2 3p 4 3d) configuration. The form of this reactivity, and the differences between the reactivity observed in these experiments and those performed at higher collision energies, are well reproduced by Landau-Zener theory

  19. Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4

    International Nuclear Information System (INIS)

    Giubrone, G.; Ortiz, J.; Gallardo, S.; Martorell, S.; Bas, M.C.

    2016-01-01

    The aim of this paper was to calculate the True Coincidence Summing Correction Factors (TSCFs) for an HPGe coaxial detector in order to correct the summing effect as a result of the presence of 88 Y and 60 Co in a multigamma source used to obtain a calibration efficiency curve. Results were obtained for three volumetric sources using the Monte Carlo toolkit, GEANT4. The first part of this paper deals with modeling the detector in order to obtain a simulated full energy peak efficiency curve. A quantitative comparison between the measured and simulated values was made across the entire energy range under study. The True Summing Correction Factors were calculated for 88 Y and 60 Co using the full peak efficiencies obtained with GEANT4. This methodology was subsequently applied to 134 Cs, and presented a complex decay scheme. - Highlights: • True Summing Correction Factors have been calculated for an HPGe detector. • GEANT4 toolkit has been used to calculate the efficiency curve for different source geometries. • Quantitative comparisons have been made using appropriate statistical tests to validate the simulations. • The average differences between simulated and measurement efficiencies are lower than 2%.

  20. Cosmologies with variable parameters and dynamical cosmon: implications on the cosmic coincidence problem

    International Nuclear Information System (INIS)

    Grande, Javier; Sola, Joan; Stefancic, Hrvoje

    2007-01-01

    Dynamical dark energy (DE) has been proposed to explain various aspects of the cosmological constant (CC) problem(s). For example, it is very difficult to accept that a strictly constant Λ-term constitutes the ultimate explanation for the DE in our Universe. It is also hard to acquiesce in the idea that we accidentally happen to live in an epoch where the CC contributes an energy density value ρ Λ = Λ/8πG right in the ballpark of the rapidly diluting matter density ρ m ∼ 1/a 3 . It should perhaps be more plausible to conceive that the vacuum energy, ρ Λ , is actually a dynamical quantity as the Universe itself. More generally, we could even entertain the possibility that the total DE is in fact a mixture of ρ Λ and other dynamical components (e.g. fields, higher order terms in the effective action etc) which can be represented collectively by an effective entity X (dubbed the 'cosmon'). The 'cosmon', therefore, acts as a dynamical DE component different from the vacuum energy. While it can actually behave phantom-like by itself, the overall DE fluid may effectively appear as standard quintessence, or even mimic at present an almost exact CC behaviour. Thanks to the versatility of such cosmic fluid we can show that a composite DE system of this sort ('ΛXCDM') may have a key to resolving the mysterious coincidence problem

  1. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Science.gov (United States)

    Liu, Bailing; Zhang, Fumin; Qu, Xinghua; Shi, Xiaojia

    2016-01-01

    Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration. PMID:26901203

  2. Coincidence Efficiency Measurement Using 11B(p,n)11C

    Science.gov (United States)

    Russ, Megan; Padalino, Stephen; Polsin, Danae; Krieger, Michael; Stillman, Collin; Bienstock, Mollie; Ellison, Drew; Simone, Angela; Yuly, Mark; Mann, Keith; Reynolds, Tyler; Sangster, Craig

    2012-10-01

    An attempt to measure the 12C(n,2n)11C cross section for high energy neutrons in the range of 20-30 MeV was conducted using Ohio University's accelerator facility as a fast neutron source. The neutrons were incident on a graphite target and the β+ decay of the activated carbon-11 nuclei were observed in an on-axis gamma ray detector pair. To pre-determine the efficiency of this gamma ray detector system, a boron-11 activation experiment was performed. Using SUNY Geneseo's 1.7 MV tandem pelletron accelerator, 3.1 MeV protons were incident upon the 11B foil inducing the 11B(p,n)11C reaction to occur at a high rate of activation. The 11C decays via β+ emission, then upon annihilation with an electron creates characteristic 511-511 keV photon pairs which were counted using coincidence methods. Since the 11B(p,n) cross section is well defined, a calculation was performed to determine the expected number of activations and later compared to the total number of decays observed in the counting system. Funded in part by a grant from the DOE through the Laboratory for Laser Energetics.

  3. Coincident nonlinear changes in the endocrine and immune systems due to low-frequency magnetic fields.

    Science.gov (United States)

    Marino, A A; Wolcott, R M; Chervenak, R; Jourd'heuil, F; Nilsen, E; Frilot, C; Pruett, S B

    2001-01-01

    The characteristic biological effects of low-frequency electromagnetic fields (EMFs) appear to be functional changes in the central nervous, endocrine and immune systems. For unapparent reasons, however, the results of similar studies have often differed markedly from one another. We recognized that it had generally been assumed, in the studies, that EMF effects would exhibit a dose-effect relationship, which is a basic property of linear systems. Prompted by recent developments in the theory on nonlinear systems, we hypothesized that there was a nonlinear relationship between EMFs and the effects they produced in the endocrine and immune systems. We developed a novel analytical method that could be used to distinguish between linear and nonlinear effects, and we employed it to examine the effect of EMFs on the endocrine and immune systems. Mice exposed to 5 G, 60 Hz for 1-175 days in 7 independent experiments reliably exhibited changes in serum corticosterone and lymphoid phenotype when the data were analyzed while allowing that the field exposure and the resulting effects could be nonlinearly related. When the analysis was restricted to linear relationships, no effects due to the field were found. The results indicated that transduction of EMFs resulted in changes in both the endocrine and immune systems, and that the laws governing the changes in each system were not the type that govern conventional dose-effect relationships. Evidence based on mathematical modeling was found suggesting that the coincident changes could have been causally related. Copyright 2001 S. Karger AG, Basel

  4. Coincident In Vitro Analysis of DNA-PK-Dependent and -Independent Nonhomologous End Joining

    Directory of Open Access Journals (Sweden)

    Cynthia L. Hendrickson

    2010-01-01

    Full Text Available In mammalian cells, DNA double-strand breaks (DSBs are primarily repaired by nonhomologous end joining (NHEJ. The current model suggests that the Ku 70/80 heterodimer binds to DSB ends and recruits DNA-PKcs to form the active DNA-dependent protein kinase, DNA-PK. Subsequently, XRCC4, DNA ligase IV, XLF and most likely, other unidentified components participate in the final DSB ligation step. Therefore, DNA-PK plays a key role in NHEJ due to its structural and regulatory functions that mediate DSB end joining. However, recent studies show that additional DNA-PK-independent NHEJ pathways also exist. Unfortunately, the presence of DNA-PKcs appears to inhibit DNA-PK-independent NHEJ, and in vitro analysis of DNA-PK-independent NHEJ in the presence of the DNA-PKcs protein remains problematic. We have developed an in vitro assay that is preferentially active for DNA-PK-independent DSB repair based solely on its reaction conditions, facilitating coincident differential biochemical analysis of the two pathways. The results indicate the biochemically distinct nature of the end-joining mechanisms represented by the DNA-PK-dependent and -independent NHEJ assays as well as functional differences between the two pathways.

  5. Rhizobitoxine-induced Chlorosis Occurs in Coincidence with Methionine Deficiency in Soybeans

    Science.gov (United States)

    Okazaki, Shin; Sugawara, Masayuki; Yuhashi, Ken-Ichi; Minamisawa, Kiwamu

    2007-01-01

    Background and Aims Rhizobitoxine, produced by the legume symbiont Bradyrhizobium elkanii, inhibits cystathionine-β-lyase (EC 4·4·1·8) in methionine biosynthesis and 1-aminocyclopropane-1-carboxylate synthase (ACC) in ethylene biosynthesis. Rhizobitoxine production by B. elkanii enhances nodulation of host legumes via the inhibition of ethylene synthesis, but causes foliar chlorosis in susceptible soybeans, though how it does so remains to be investigated. The aim of this study was to examine the physiological basis of rhizobitoxine-induced chlorosis in soybeans. Methods Wild-type B. elkanii and a rhizobitoxine-deficient mutant were inoculated in Glycine max ‘Lee’. Thirty days after inoculation, the upper parts of soybean shoots were analysed for amino acid contents. Chlorotic soybeans inoculated with wild-type B. elkanii were treated with methionine and ACC to assess the effects of the chemicals on the chlorosis. Key Results Chlorotic upper shoots of soybeans inoculated with wild-type B. elkanii had a lower methionine content and higher accumulation of the methionine precursors than those with the rhizobitoxine-deficient mutant. In addition, the foliar chlorosis was alleviated by the application of methionine. Conclusions Rhizobitoxine-induced chlorosis occurs in coincidence with methionine deficiency as a result of cystathione-β-lyase inhibition during methionine biosynthesis. PMID:17525098

  6. Radar Coincidence Imaging for Off-Grid Target Using Frequency-Hopping Waveforms

    Directory of Open Access Journals (Sweden)

    Xiaoli Zhou

    2016-01-01

    Full Text Available Radar coincidence imaging (RCI is a high-resolution staring imaging technique without the limitation of the target relative motion. To achieve better imaging performance, sparse reconstruction is commonly used. While its performance is based on the assumption that the scatterers are located at the prediscretized grid-cell centers, otherwise, off-grid emerges and the performance of RCI degrades significantly. In this paper, RCI using frequency-hopping (FH waveforms is considered. The off-grid effects are analyzed, and the corresponding constrained Cramér-Rao bound (CCRB is derived based on the mean square error (MSE of the “oracle” estimator. For off-grid RCI, the process is composed of two stages: grid matching and off-grid error (OGE calibration, where two-dimension (2D band-excluded locally optimized orthogonal matching pursuit (BLOOMP and alternating iteration minimization (AIM algorithms are proposed, respectively. Unlike traditional sparse recovery methods, BLOOMP realizes the recovery in the refinement grids by overwhelming the shortages of coherent dictionary and is robust to noise and OGE. AIM calibration algorithm adaptively adjusts the OGE and, meanwhile, seeks the optimal target reconstruction result.

  7. First coincidences in pre-clinical Compton camera prototype for medical imaging

    Science.gov (United States)

    Studen, A.; Burdette, D.; Chesi, E.; Cindro, V.; Clinthorne, N. H.; Dulinski, W.; Fuster, J.; Han, L.; Kagan, H.; Lacasta, C.; Llosá, G.; Marques, A. C.; Malakhov, N.; Meier, D.; Mikuž, M.; Park, S. J.; Roe, S.; Rogers, W. L.; Steinberg, J.; Weilhammer, P.; Wilderman, S. J.; Zhang, L.; Žontar, D.

    2004-09-01

    Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500μm thick, 256 pad silicon detector with pad size of 1.4×1.4mm2, combined with a 15×15×1cm3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (σ) of the spectroscopic outputs gave an equivalent noise charge (ENC) with a mean value of =137e with a spread of 10e, corresponding to an energy resolution of 1.15keV FWHM for the scattered electron energy. Threshold settings above 8.2keV were required for stable operation of the trigger. Coincident Compton scatter events in both modules were observed for photons emitted by 57Co source with principal gamma ray energies of 122 and 136keV.

  8. The Rare Coincidence: Nonrecurrent Laryngeal Nerve Pointed by a Zuckerkandl's Tubercle

    Directory of Open Access Journals (Sweden)

    Emin Gurleyik

    2012-01-01

    Full Text Available The safety of thyroid operations mainly depends on complete anatomical knowledge. Anatomical and embryological variations of the inferior laryngeal nerve (ILN, of the thyroid gland itself and unusual relations between ILN and the gland threaten operation security are discussed. The patient with toxic multinodular goiter is treated with total thyroidectomy. During dissection of the right lobe, the right ILN which has nonrecurrent course arising directly from cervical vagus nerve is identified and fully isolated until its laryngeal entry. At the operation, we observe bilateral Zuckerkandl's tubercles (ZTs as posterior extension of both lateral lobes. The left ILN has usual recurrent course in the trachea-esophageal groove. The right ZT is placed between upper and middle third of the lobe points the nonrecurrent ILN. The coincidence of non-recurrent ILN pointed by a ZT is rare anatomical and embryological feature of this case. Based on anatomical and embryological variations, we suggest identification and full exposure of ILN before attempting excision of adjacent structures, like the ZT which has surgical importance for completeness of thyroidectomy.

  9. Does functional recovery of hibernating myocardium coincide with improvement in perfusion?

    International Nuclear Information System (INIS)

    Takeishi, Yasuchika; Tonooka, Ichiro; Chiba, Junya; Abe, Shinya; Tsuiki, Kai; Tomoike, Hitonobu; Yasui, Shoji.

    1992-01-01

    To determine how much recovery of hibernating myocardium coincide with perfusion improvement, 49 patients underwent radionuclide left ventriculography and exercise Tl-201 myocardial scintigraphy (Ex-Tl) before and one month after coronary artery bypass grafting (CABG). The left ventricle was divided into 6 segments for the assessment of wall motion and Tl-201 uptake. One month after CABG, wall motion improvement was found in a total of 74 segments (seg A), and was also associated with perfusion improvement in 66 segments (89%). Although 8 segments showed wall motion improvement at follow-up examinations (seg B), 7 (88%) had been improved for perfusion one month after CABG. Preoperative akinesis or dyskinesis was more frequently observed for seg B (75%) than seg A (34%). Similarly, seg B was associated with lower %Tl-201 uptake as compared with seg A (74±9% vs 83±8%). In conclusion, perfusion recovery preceded recovery of hibernating myocardium in some segments, suggesting the involvement of stunned myocardium. These segments were associated with severe wall motion abnormality before CABG and lower Tl-201 uptake. (N.K.)

  10. Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics and architectural comparison of polarimeter techniques

    Science.gov (United States)

    Yang, Ruonan; Sen, Pratik; O'Connor, B. T.; Kudenov, M. W.

    2017-08-01

    An intrinsic coincident full-Stokes polarimeter is demonstrated by using stain-aligned polymer-based organic photovoltaics (OPVs) which can preferentially absorb certain polarized states of incident light. The photovoltaic-based polarimeter is capable of measuring four stokes parameters by cascading four semitransparent OPVs in series along the same optical axis. Two wave plates were incorporated into the system to modulate the S3 stokes parameter so as to reduce the condition number of the measurement matrix. The model for the full-Stokes polarimeter was established and validated, demonstrating an average RMS error of 0.84%. The optimization, based on minimizing the condition number of the 4-cell OPV design, showed that a condition number of 2.4 is possible. Performance of this in-line polarimeter concept was compared to other polarimeter architectures, including Division of Time (DoT), Division of Amplitude (DoAm), Division of Focal Plane (DoFP), and Division of Aperture (DoA) from signal-to-noise ratio (SNR) perspective. This in-line polarimeter concept has the potential to enable both high temporal (as compared with a DoT polarimeter) and high spatial resolution (as compared with DoFP and DoA polarimeters). We conclude that the intrinsic design has the same √2 SNR advantage as the DoAm polarimeter, but with greater compactness.

  11. Severe mammal declines coincide with proliferation of invasive Burmese pythons in Everglades National Park

    Science.gov (United States)

    Dorcas, Michael E.; Wilson, John D.; Reed, Robert N.; Snow, Ray W.; Rochford, Michael R.; Miller, Melissa A.; Meshaka, Walter E.; Andreadis, Paul T.; Mazzotti, Frank J.; Romagosa, Christina M.; Hart, Kristen M.

    2012-01-01

    Invasive species represent a significant threat to global biodiversity and a substantial economic burden. Burmese pythons, giant constricting snakes native to Asia, now are found throughout much of southern Florida, including all of Everglades National Park (ENP). Pythons have increased dramatically in both abundance and geographic range since 2000 and consume a wide variety of mammals and birds. Here we report severe apparent declines in mammal populations that coincide temporally and spatially with the proliferation of pythons in ENP. Before 2000, mammals were encountered frequently during nocturnal road surveys within ENP. In contrast, road surveys totaling 56,971 km from 2003–2011 documented a 99.3% decrease in the frequency of raccoon observations, decreases of 98.9% and 87.5% for opossum and bobcat observations, respectively, and failed to detect rabbits. Road surveys also revealed that these species are more common in areas where pythons have been discovered only recently and are most abundant outside the python's current introduced range. These findings suggest that predation by pythons has resulted in dramatic declines in mammals within ENP and that introduced apex predators, such as giant constrictors, can exert significant top-down pressure on prey populations. Severe declines in easily observed and/or common mammals, such as raccoons and bobcats, bode poorly for species of conservation concern, which often are more difficult to sample and occur at lower densities.

  12. Flow structure from a horizontal cylinder coincident with a free surface in shallow water flow

    Directory of Open Access Journals (Sweden)

    Kahraman Ali

    2012-01-01

    Full Text Available Vortex formation from a horizontal cylinder coincident with a free surface of a shallow water flow having a depth of 25.4 [mm] was experimentally investigated using the PIV technique. Instantaneous and time-averaged flow patterns in the wake region of the cylinder were examined for three different cylinder diameter values under the fully developed turbulent boundary layer condition. Reynolds numbers were in the range of 1124£ Re£ 3374 and Froude numbers were in the range of 0.41 £ Fr £ 0.71 based on the cylinder diameter. It was found that a jet-like flow giving rise to increasing the flow entrainment between the core and wake regions depending on the cylinder diameter was formed between the lower surface of the cylinder and bottom surface of the channel. Vorticity intensity, Reynolds stress correlations and the primary recirculating bubble lengths were grown to higher values with increasing the cylinder diameter. On the other hand, in the case of the lowest level of the jet-like flow emanating from the beneath of the smallest cylinder, the variation of flow characteristics were attenuated significantly in a shorter distance. The variation of the reattachment location of the separated flow to the free-surface is a strong function of the cylinder diameter and the Froude number.

  13. Performances evaluation of the coincidence detection on a gamma-camera

    International Nuclear Information System (INIS)

    Dreuille, O. de; Gaillard, J.F.; Brasse, D.; Bendriem, B.; Groiselle, C.; Rocchisani, J.M.; Moretti, J.L.

    2000-01-01

    The performance of the VERTEX gamma-camera (ADAC) working in coincidence mode are investigated using a protocol derived from the NEMA and IEC recommendations. With a field of view determined by two rectangular detectors (50.8 cm x 40 cm) composed of NaI crystal, this camera allows a 3-D acquisition with different energy window configurations: photopeak-photopeak only (PP) and photopeak-photopeak + photopeak-Compton (PC). An energy resolution of 11% and a scatter fraction of 27% and 33% for the 3D-PP and 3D-PC mode respectively are the main significant results of our study. The spatial resolution equals 5.9 mm and the limit of the detectability ranges from 16 mm to 13 mm for a contrast of 2.5: as a function of the random estimation, the maximum of the Noise Equivalent Count rate varies from 3 kcps to 4.5 kcps for the PP mode and from 3.85 kcps to 6.1 kcps for the PC mode. These maxima are reached for a concentration of 8 kBq/ml for the PP mode and 5 kBq/ml for the PC mode. These values are compared with the results obtained by other groups for the VERTEX gamma camera and several dedicated PET systems. (authors)

  14. Automatic classification of gammas-gamma coincidence matrices; Clasificacion automatizada de matrices de coincidencias Gamma-Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos Merino, J. M.; Gonzalez, J. A.

    1978-07-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a MULTI-8 minicomputer, is transferred to a new tape in 36 bit words, using the program LEC0M8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program CLAFI. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the UNIVAC 1106 computer of J.E.N. (Author) 4 refs.

  15. Software for the on-off-line A-A-T coincidence experiment with use of semiconductor detector of nuclear radiation

    International Nuclear Information System (INIS)

    Samatov, Zh.K.; Fominyh, V.I.; Gromov, K.Ya; Samatov, Zh.K.; Safarov, A.N.

    2006-01-01

    Full text: In γ-spectra measurements with 200 cm 3 HPGe-detector with energy resolution (FWHM) of 3.5 keV for α-rays 1.33 MeV 60 Co, 60 cm 3 Ge(Li)-detector with energy resolution of 1.9 keV for γ -rays 1.33 MeV 60 Co, 2 cm 3 HPGe-detector with energy resolution of 1.0 keV for α-rays 122 keV 57 Co and planar 250 mm 3 HPGe-detector with energy resolution of 0.5 keV for γ -rays 53 keV 133 Ba. For accumulation and analysis of the experimental information the analog electronics produced companies ORTEC, CANBERRA, Dzhelepov Laboratory of Nuclear Problem of JINR, units of the digital electronics of standard KAMAK, personal computers were used. The accumulation of information on the coincidence spectra was provided by record of each event (E 1 , E 2 , t)-coincidence (in list mode) and single spectra E 1 and E 2 that gave the broad possibilities for analysis result after completion experiment by means of the multiple sorting of information on spectra of the coincidences with installation the energy and time windows. In the report, a description of programs of the management and control of the on-off-line experiment designed at the begin 90-s being performed in Dubna by the YASNAPP-2 program [1-3] on the experimental complex for study nuclei far from the drip-line β-stability is given. The publication of the description of controlling programs is retard from publication of descriptions of the measuring equipment and result of the physical studies [4-6] due to in particular with creation in Institute of Nuclear Physics in Tashkent of the experimental complex γ-γ -coincidences, which can be used to accumulate the unpublished material by authors. The programs are formed in the Turbo-Pascal language with reference to the KAMAK-standard digital equipment and spectrometric equipment in standard NIM. It is properly to classify beforehand the programs in amount of 50 items: Program of the accumulation coincidence spectra of the type A-A-T with using the digital windows and

  16. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Knudsen, L; Jensen, K

    1991-01-01

    In a cross-sectional investigation of 116 patients with multiple sclerosis, the social and sparetime activities of the patient were assessed by both patient and his/her family. The assessments were correlated to physical disability which showed that particularly those who were moderately disabled...

  17. Multiple Myeloma

    African Journals Online (AJOL)

    The results of the use of melphalan in 52 patients with multiple myeloma have been analysed. The median survival of the whole group of patients was 30 months, and of those w:th renal insufficiency only 12,5 months. Bence-lones proteinuria was also a poor prognostic finding,. but only because of its association with renal ...

  18. Multiple Sclerosis.

    Science.gov (United States)

    Plummer, Nancy; Michael, Nancy, Ed.

    This module on multiple sclerosis is intended for use in inservice or continuing education programs for persons who administer medications in long-term care facilities. Instructor information, including teaching suggestions, and a listing of recommended audiovisual materials and their sources appear first. The module goal and objectives are then…

  19. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Jensen, K

    1988-01-01

    Forty-two (12%) of a total of 366 patients with multiple sclerosis (MS) had psychiatric admissions. Of these, 34 (81%) had their first psychiatric admission in conjunction with or after the onset of MS. Classification by psychiatric diagnosis showed that there was a significant positive correlati...

  20. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Jensen, K

    1990-01-01

    An investigation on the correlation between ability to read TV subtitles and the duration of visual evoked potential (VEP) latency in 14 patients with definite multiple sclerosis (MS), indicated that VEP latency in patients unable to read the TV subtitles was significantly delayed in comparison...

  1. Clearance of an immunosuppressive virus from the CNS coincides with immune reanimation and diversification

    Directory of Open Access Journals (Sweden)

    McGavern Dorian B

    2007-06-01

    Full Text Available Abstract Once a virus infection establishes persistence in the central nervous system (CNS, it is especially difficult to eliminate from this specialized compartment. Therefore, it is of the utmost importance to fully understand scenarios during which a persisting virus is ultimately purged from the CNS by the adaptive immune system. Such a scenario can be found following infection of adult mice with an immunosuppressive variant of lymphocytic choriomeningitis virus (LCMV referred to as clone 13. In this study we demonstrate that following intravenous inoculation, clone 13 rapidly infected peripheral tissues within one week, but more slowly inundated the entire brain parenchyma over the course of a month. During the establishment of persistence, we observed that genetically tagged LCMV-specific cytotoxic T lymphocytes (CTL progressively lost function; however, the severity of this loss in the CNS was never as substantial as that observed in the periphery. One of the most impressive features of this model system is that the peripheral T cell response eventually regains functionality at ~60–80 days post-infection, and this was associated with a rapid decline in virus from the periphery. Coincident with this "reanimation phase" was a massive influx of CD4 T and B cells into the CNS and a dramatic reduction in viral distribution. In fact, olfactory bulb neurons served as the last refuge for the persisting virus, which was ultimately purged from the CNS within 200 days post-infection. These data indicate that a functionally revived immune response can prevail over a virus that establishes widespread presence both in the periphery and brain parenchyma, and that therapeutic enhancement of an existing response could serve as an effective means to thwart long term CNS persistence.

  2. Development and Testing of the Positron Identification By Coincident Annihilation Photons (PICAP) System

    Science.gov (United States)

    Tran, D.; Connell, J. J.; Lopate, C.; Bickford, B.

    2014-12-01

    Moderate energy positrons (~few to 10 MeV) have seldom been observed in the Heliosphere, due primarily to there not having been dedicated instruments for such measurements. Their detection would have implications in the study of Solar energetic particle events and the transport and modulation of the Solar wind and Galactic cosmic rays. The Positron Identification by Coincident Annihilation Photons (PICAP) system is designed specifically to measure these moderate energy positrons by simultaneously detecting the two 511-keV γ-ray photons that result from a positron stopping in the instrument and the subsequent electron-positron annihilation. This method is also expected to effectively discriminate positrons from protons by measuring the amount of energy deposited in the detectors (dE/dx versus residual energy). PICAP offers a low-mass, low-power option for measuring positrons, electrons, and ions in space. Following Monte Carlo modeling, a PICAP laboratory prototype, adaptable to a space-flight design, was designed, built, and tested. This instrument is comprised of (Si) solid-state detectors, plastic scintillation detectors, and high-Z BGO crystal scintillator suitable for detecting the 511-keV γ rays. The prototype underwent preliminary laboratory testing and calibration using radioactive sources for the purpose of establishing functionality. It has since been exposed to beams of energetic protons (up to ~200 MeV) at Massachusetts General Hospital's Francis H. Burr Proton Beam Therapy Center and positrons and electrons (up to ~10 MeV) at Idaho State University's Idaho Accelerator Center. The goal is to validate modeling and determine the performance of the instrument concept. We will present a summary of modeling calculations and analysis of data taken at the accelerator tests. This work is 95% supported by NASA Grant NNX10AC10G.

  3. The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a program overview

    Science.gov (United States)

    Macculi, C.; Argan, A.; D'Andrea, M.; Lotti, S.; Laurenza, M.; Piro, L.; Biasotti, M.; Corsini, D.; Gatti, F.; Torrioli, G.; Fiorini, M.; Molendi, S.; Uslenghi, M.; Mineo, T.; Bulgarelli, A.; Fioretti, V.; Cavazzuti, E.

    2016-07-01

    The ATHENA observatory is the second large-class ESA mission, in the context of the Cosmic Vision 2015 - 2025, scheduled to be launched on 2028 at L2 orbit. One of the two on-board instruments is the X-IFU (X-ray Integral Field Unit): it is a TES-based kilo-pixels order array able to perform simultaneous high-grade energy spectroscopy (2.5 eV at 6 keV) and imaging over the 5 arcmin FoV. The X-IFU sensitivity is degraded by the particles background which is induced by primary protons of both solar and Cosmic Rays origin, and secondary electrons. The studies performed by Geant4 simulations depict a scenario where it is mandatory the use of reduction techniques that combine an active anticoincidence detector and a passive electron shielding to reduce the background expected in L2 orbit down to the goal level of 0.005 cts/cm2/s/keV, so enabling the characterization of faint or diffuse sources (e.g. WHIM or Galaxy cluster outskirts). From the detector point of view this is possible by adopting a Cryogenic AntiCoincidence (CryoAC) placed within a proper optimized environment surrounding the X-IFU TES array. It is a 4-pixels detector made of wide area Silicon absorbers sensed by Ir TESes, and put at a distance design of the CryoAC. Both the background studies and the detector development work is on-going to provide confident results about the expected residual background at the TES-array level, and the single pixel design to produce a detector for testing activity on 2016/2017. Here we will provide an overview of the CryoAC program, discussing some details about the background assessment having impact on the CryoAC design, the last single pixel characterization, the structural issues, followed by some programmatic aspects.

  4. Binding energies and isomerization in metallocene ions from threshold photoelectron photoion coincidence spectroscopy.

    Science.gov (United States)

    Révész, Agnes; Szepes, László; Baer, Tomas; Sztáray, Bálint

    2010-12-22

    Metallocene ions (Cp(2)M(+), M = Cr, Co, Ni) were studied by threshold photoelectron photoion coincidence spectroscopy (TPEPICO) to investigate the mechanism, energetics, and kinetics of the ionic dissociation processes. The examined energy-selected Cp(2)M(+) ions fragment by losing the neutral cyclopentadienyl ligand. In addition, CH and C(2)H(2) losses appear as minor channels, while the cobaltocene ion also loses an H atom. A possible isomerization pathway has also been observed for Cp(2)Ni(+), yielding a complex with pentafulvalene (C(10)H(8)) with a loss of H(2). In order to determine the 0 K appearance energies for the CpM(+) fragment ions, the asymmetric time-of-flight peak shapes and the breakdown diagrams of the energy-selected metallocene ions were modeled by both the rigid activated complex (RAC) Rice-Ramsperger-Kassel-Marcus (RRKM) theory and the simplified statistical adiabatic channel model (SSACM). The following appearance energies were obtained with SSACM, which is more reliable for loose transition states: 10.57 ± 0.14, 11.01 ± 0.13, and 10.18 ± 0.13 eV for M = Cr, Co, and Ni, respectively. These values combined with the corresponding adiabatic ionization energies yield M-Cp bond dissociation energies in Cp(2)M(+) ions of 5.04 ± 0.16, 5.77 ± 0.15, and 3.96 ± 0.15 eV. Density functional calculations at the B3LYP/6-311G(d,p) level of theory were used to determine the structures of these complexes and to provide parameters necessary for the analysis of the experimental data. The trends in the M-Cp bond energies can be related to the electronic structures of the metallocene ions based on a simple molecular orbital picture.

  5. Acute motor axonal neuropathy associated with anal carcinoma: Paraneoplastic neurological syndrome or coincidence?

    International Nuclear Information System (INIS)

    Lopez, J. L.; Amezcua, S.; Pascual, J.; Algara, M.

    2011-01-01

    Aim: Assessment of the association of an acute motor axonal neuropathy with a squamous cell anal carcinoma. Background: Paraneoplastic neurologic syndromes are not a direct consequence of neither primary tumor nor its metastasis. They often parallel the course of the malignancy but may be the presenting sign of an occult cancer. Sometimes it is very difficult to distinguish if it is a paraneoplastic syndrome or just a coincidence. Materials and methods: We report a 60-year-old man that presented with an acute motor deficit of the four limbs. Clinical examination found a pure and severe motor deficit in the four limbs. No sensory abnormality was found and all motor nerves were unexcitable. Electromyography suggested the diagnosis of acute motor axonal neuropathy (AMAN). Four months after developing the AMAN, blood in the stool revealed anal carcinoma. The patient was treated with concurrent chemoradiotherapy. Radiation was given to the tumor and to the pelvis, including inguinal nodes, over a five-week period plus fluorouracil and mitomycin. We investigated the presence of anti ganglioside antibodies as studies suggest that carcinomas can express antigens shared with Schwann cells. Results: Anti-GM1 IgG antibodies were detected by an enzyme-linked immunosorbent assay method. Other antibodies, including antinuclear nucleoprotein antibody (anti-Hu), anti-Tr, anti-Ri, anti-CV2, anti-amphiphysin and anti-Yo, were negative. Clinical improvement of the motor state was observed at the fourth week of oncologic treatment. Conclusion: The presence of anti-GM1 IgG antibodies and the clinical improvement of the motor state after concurrent chemoradiotherapy lead us to believe there is an association between anal carcinoma and this severe impairment. (authors)

  6. Epidemic pasteurellosis in a bighorn sheep population coinciding with the appearance of a domestic sheep.

    Science.gov (United States)

    George, Janet L; Martin, Daniel J; Lukacs, Paul M; Miller, Michael W

    2008-04-01

    A pneumonia epidemic reduced bighorn sheep (Ovis canadensis) survival and recruitment during 1997-2000 in a population comprised of three interconnected wintering herds (Kenosha Mountains, Sugarloaf Mountain, Twin Eagles) that inhabited the Kenosha and Tarryall Mountain ranges in central Colorado, USA. The onset of this epidemic coincided temporally and spatially with the appearance of a single domestic sheep (Ovis aires) on the Sugarloaf Mountain herd's winter range in December 1997. Although only bighorns in the Sugarloaf Mountain herd were affected in 1997-98, cases also occurred during 1998-99 in the other two wintering herds, likely after the epidemic spread via established seasonal movements of male bighorns. In all, we located 86 bighorn carcasses during 1997-2000. Three species of Pasteurella were isolated in various combinations from affected lung tissues from 20 bighorn carcasses where tissues were available and suitable for diagnostic evaluation; with one exception, beta-hemolytic mannheimia (Pasteurella) haemolytica (primarily reported as biogroup 1(G) or 1(alphaG)) was isolated from lung tissues of cases evaluated during winter 1997-98. The epidemic dramatically lowered adult bighorn monthly survival in all three herds; a model that included an acute epidemic effect, differing between sexes and with vaccination status, that diminished linearly over the next 12 mo best represented field data. In addition to the direct mortality associated with epidemics in these three herds, lamb recruitment in years following the pneumonia epidemic also was depressed as compared to years prior to the epidemic. Based on observations presented here, pasteurellosis epidemics in free-ranging bighorn sheep can arise through incursion of domestic sheep onto native ranges, and thus minimizing contact between domestic and bighorn sheep appears to be a logical principle for bighorn sheep conservation.

  7. Shifting brucellosis risk in livestock coincides with spreading seroprevalence in elk

    Science.gov (United States)

    Brennan, Angela; Cross, Paul C.; Portacci, Katie; Scurlock, Brandon M.; Edwards, William H.

    2017-01-01

    Tracking and preventing the spillover of disease from wildlife to livestock can be difficult when rare outbreaks occur across large landscapes. In these cases, broad scale ecological studies could help identify risk factors and patterns of risk to inform management and reduce incidence of disease. Between 2002 and 2014, 21 livestock herds in the Greater Yellowstone Area (GYA) were affected by brucellosis, a bacterial disease caused by Brucella abortus, while no affected herds were detected between 1990 and 2001. Using a Bayesian analysis, we examined several ecological covariates that may be associated with affected livestock herds across the region. We showed that livestock risk has been increasing over time and expanding outward from the historical nexus of brucellosis in wild elk on Wyoming’s feeding grounds where elk are supplementally fed during the winter. Although elk were the presumed source of cattle infections, occurrences of affected livestock herds were only weakly associated with the density of seropositive elk across the GYA. However, the shift in livestock risk did coincide with recent increases in brucellosis seroprevalence in unfed elk populations. As increasing brucellosis in unfed elk likely stemmed from high levels of the disease in fed elk, disease-related costs of feeding elk have probably been incurred across the entire GYA, rather than solely around the feeding grounds. Our results suggest that focused disease mitigation in areas where seroprevalence in unfed elk is high could reduce the spillover of brucellosis to livestock. We also highlight the need to better understand the epidemiology of spillover events with detailed histories of disease testing, calving, and movement of infected livestock. Finally, we recommend using case-control studies to investigate local factors important to livestock risk.

  8. Shifting brucellosis risk in livestock coincides with spreading seroprevalence in elk.

    Directory of Open Access Journals (Sweden)

    Angela Brennan

    Full Text Available Tracking and preventing the spillover of disease from wildlife to livestock can be difficult when rare outbreaks occur across large landscapes. In these cases, broad scale ecological studies could help identify risk factors and patterns of risk to inform management and reduce incidence of disease. Between 2002 and 2014, 21 livestock herds in the Greater Yellowstone Area (GYA were affected by brucellosis, a bacterial disease caused by Brucella abortus, while no affected herds were detected between 1990 and 2001. Using a Bayesian analysis, we examined several ecological covariates that may be associated with affected livestock herds across the region. We showed that livestock risk has been increasing over time and expanding outward from the historical nexus of brucellosis in wild elk on Wyoming's feeding grounds where elk are supplementally fed during the winter. Although elk were the presumed source of cattle infections, occurrences of affected livestock herds were only weakly associated with the density of seropositive elk across the GYA. However, the shift in livestock risk did coincide with recent increases in brucellosis seroprevalence in unfed elk populations. As increasing brucellosis in unfed elk likely stemmed from high levels of the disease in fed elk, disease-related costs of feeding elk have probably been incurred across the entire GYA, rather than solely around the feeding grounds. Our results suggest that focused disease mitigation in areas where seroprevalence in unfed elk is high could reduce the spillover of brucellosis to livestock. We also highlight the need to better understand the epidemiology of spillover events with detailed histories of disease testing, calving, and movement of infected livestock. Finally, we recommend using case-control studies to investigate local factors important to livestock risk.

  9. Electron irradiation effect of polyurethane using coincidence doppler-broadening spectroscopy

    International Nuclear Information System (INIS)

    Yang, D.J.; Zhang, J.D.; Leung, J.K.C.; Beling, C.D.; Liu, L.B.

    2006-01-01

    Full text: To understand the electron irradiation effects on polymer, polyether-urethane (ETPU) samples of 2m m in thickness and 1 0 m m in diameter were irradiated by a 1.8M eV electron beam with beam current of 3 ma at room temperature. The irradiated doses are 5 kGy, 10 kGy, 15 kGy, 30 kGy, 100 kGy and 150 kGy. ETPU was manufactured by mixing PTMG-100, TDI-100 and MOCA. The momentum density distributions (MMDs) of electrons taking part in the annihilation processes of positron-electron pairs in ETPU have been measured by coincidence Doppler-broadening spectroscopy (CDBS). By presenting the ratio of the counts in every channel of the measured CDB spectrum to the corresponding counts from a reference spectrum (pristine ETPU), we observed that the change in MMDs is not significant for doses lower than 10 kGy. However, high momentum part of MMDs exhibit an obvious decrease for dose exceeding 15 kGy and then slowly down to steady with doses until 150 kGy. This valley occurs at around 15 x1 0 3m οc and is well known as oxygen-specific, indicative of a less positron trapping by oxygen atoms in some samples of higher dose radiation. It is postulated that the radiation will break the crosslinkings, allowing the trace water and oxygen molecules to be released from the sample surface. Excess NCO groups in ETPU would crosslink with urethane and urea groups to produce allophanate and biuret groups. After receiving a certain amount of electron irradiation, crosslinked allophanate and biuret groups would produce degradation. Thus, residual water and oxygen trapped in ETPU by the crosslinking would diffuse out. However, the irradiation doses up to 150 kGy in this experiment are still not large enough to induce strong degradation of urethane and urea groups

  10. Early dystrophin loss is coincident with the transition of compensated cardiac hypertrophy to heart failure.

    Science.gov (United States)

    Prado, Fernanda P; Dos Santos, Daniele O; Blefari, Valdecir; Silva, Carlos A; Machado, Juliano; Kettelhut, Isis do Carmo; Ramos, Simone G; Baruffi, Marcelo Dias; Salgado, Helio C; Prado, Cibele M

    2017-01-01

    Hypertension causes cardiac hypertrophy, one of the most important risk factors for heart failure (HF). Despite the importance of cardiac hypertrophy as a risk factor for the development of HF, not all hypertrophied hearts will ultimately fail. Alterations of cytoskeletal and sarcolemma-associated proteins are considered markers cardiac remodeling during HF. Dystrophin provides mechanical stability to the plasma membrane through its interactions with the actin cytoskeleton and, indirectly, to extracellular matrix proteins. This study was undertaken to evaluate dystrophin and calpain-1 in the transition from compensated cardiac hypertrophy to HF. Wistar rats were subjected to abdominal aorta constriction and killed at 30, 60 and 90 days post surgery (dps). Cardiac function and blood pressure were evaluated. The hearts were collected and Western blotting and immunofluorescence performed for dystrophin, calpain-1, alpha-fodrin and calpastatin. Statistical analyses were performed and considered significant when pDystrophin expression was lightly increased at 30 and 60 dps and HH group. HD group showed decreased expression of dystrophin and calpastatin and increased expression of calpain-1 and alpha-fodrin fragments. The first signals of dystrophin reduction were observed as early as 60 dps. In conclusion, some hearts present a distinct molecular pattern at an early stage of the disease; this pattern could provide an opportunity to identify these failure-prone hearts during the development of the cardiac disease. We showed that decreased expression of dystrophin and increased expression of calpains are coincident and could work as possible therapeutic targets to prevent heart failure as a consequence of cardiac hypertrophy.

  11. Functional recovery of hibernating myocardium after coronary bypass surgery: Does it coincide with improvement in perfusion

    International Nuclear Information System (INIS)

    Takeishi, Y.; Tono-oka, I.; Kubota, I.; Ikeda, K.; Masakane, I.; Chiba, J.; Abe, S.; Tsuiki, K.; Komatani, A.; Yamaguchi, I.

    1991-01-01

    To determine the relationship between functional recovery and improvement in perfusion after coronary artery bypass graft surgery (CABG), 49 patients were studied. Radionuclide angiography was performed before, 1 month after, and 6 to 12 months after CABG to evaluate regional wall motion. Exercise thallium-201 myocardial perfusion imaging was done before and 1 month after CABG to assess regional perfusion. Preoperative asynergy was observed in 108 segments, and 74 of them showed an improvement in wall motion 1 month after CABG (segment A). Sixty-six of these segments (89%) were associated with an improvement in perfusion. Eight segments that had not improved 1 month after CABG demonstrated a delayed recovery of wall motion 6 to 12 months after CABG (segment B). However, seven of eight segments (88%) already showed an improvement in perfusion 1 month after CABG. A total of 82 segments exhibited functional recovery after CABG and were considered hibernating segments. In the preoperative study segment B more frequently had areas of akinesis or dyskinesis than segment A (75% vs 34%, p less than 0.05). The mean percent thallium-201 uptake in segment B was lower than that in segment A (74% ± 9% vs 83% ± 8%, p less than 0.05). Functional recovery of hibernating myocardium usually coincided with an improvement in perfusion. However, delayed functional recovery after reperfusion was observed in some instances. Severe asynergy and severe thallium-201 defects were more frequently observed in these segments with delayed recovery. Hibernating myocardium might remain stunned during those recovery periods

  12. Shifting brucellosis risk in livestock coincides with spreading seroprevalence in elk.

    Science.gov (United States)

    Brennan, Angela; Cross, Paul C; Portacci, Katie; Scurlock, Brandon M; Edwards, William H

    2017-01-01

    Tracking and preventing the spillover of disease from wildlife to livestock can be difficult when rare outbreaks occur across large landscapes. In these cases, broad scale ecological studies could help identify risk factors and patterns of risk to inform management and reduce incidence of disease. Between 2002 and 2014, 21 livestock herds in the Greater Yellowstone Area (GYA) were affected by brucellosis, a bacterial disease caused by Brucella abortus, while no affected herds were detected between 1990 and 2001. Using a Bayesian analysis, we examined several ecological covariates that may be associated with affected livestock herds across the region. We showed that livestock risk has been increasing over time and expanding outward from the historical nexus of brucellosis in wild elk on Wyoming's feeding grounds where elk are supplementally fed during the winter. Although elk were the presumed source of cattle infections, occurrences of affected livestock herds were only weakly associated with the density of seropositive elk across the GYA. However, the shift in livestock risk did coincide with recent increases in brucellosis seroprevalence in unfed elk populations. As increasing brucellosis in unfed elk likely stemmed from high levels of the disease in fed elk, disease-related costs of feeding elk have probably been incurred across the entire GYA, rather than solely around the feeding grounds. Our results suggest that focused disease mitigation in areas where seroprevalence in unfed elk is high could reduce the spillover of brucellosis to livestock. We also highlight the need to better understand the epidemiology of spillover events with detailed histories of disease testing, calving, and movement of infected livestock. Finally, we recommend using case-control studies to investigate local factors important to livestock risk.

  13. Study of a 4πβ-γ coincidence system for absolute radionuclide activity measurement using plastic scintillators

    International Nuclear Information System (INIS)

    Piuvezam Filho, Helio

    2007-01-01

    The present work was intended to study a coincidence system 4π(PS)β-γ for absolute activity measurement using plastic scintillators in 4π geometry. Along with experiments on the coincidence system, simulations were also performed applying the Monte Carlo Method, by means of codes PENELOPE and ESQUEMA. These simulations were performed in order to calculate the extrapolation curve of the coincidence system 4π(PS)β-γ and compare it to experimental data. A new geometry was proposed to the coincidence system adding up a second photomultiplier tube to the previous system for improving light collection from the plastic scintillator, as this system presented limitations in the minimum detected energy due to the presence of electronic noise and low gain. The results show that an improvement in the signal-to-noise ratio was obtained, as well as in the minimum detected energy. Moreover, there was an increase in the detection efficiency. With these modifications, it is now possible to calibrate radionuclides which emit low energy electrons or X-rays, increasing the number of radionuclides that can be standardized with this type of system.(author)

  14. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter)

    International Nuclear Information System (INIS)

    Sartory, M.

    1953-01-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X K photons and photons γ issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4π was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [fr

  15. Multiple Parenting

    OpenAIRE

    Dias, Paulo Cezar; Gramstrup, Erik Frederico

    2016-01-01

    With the modification of the family concept in human history, now considered the site of important value, aimed at personal fulfillment of its members, in line with the Federal Constitution of 1988 was enshrined in the principles of human dignity, affection, equal affiliations and plurality of family entities, recognizing the socio-affective parenting, founded in the state of emotional child, and biological, originally from consanguinity ties, arises multiple parenting in response to the full...

  16. Multiple sclerosis.

    Science.gov (United States)

    Thompson, Alan J; Baranzini, Sergio E; Geurts, Jeroen; Hemmer, Bernhard; Ciccarelli, Olga

    2018-03-22

    Multiple sclerosis continues to be a challenging and disabling condition but there is now greater understanding of the underlying genetic and environmental factors that drive the condition, including low vitamin D levels, cigarette smoking, and obesity. Early and accurate diagnosis is crucial and is supported by diagnostic criteria, incorporating imaging and spinal fluid abnormalities for those presenting with a clinically isolated syndrome. Importantly, there is an extensive therapeutic armamentarium, both oral and by infusion, for those with the relapsing remitting form of the disease. Careful consideration is required when choosing the correct treatment, balancing the side-effect profile with efficacy and escalating as clinically appropriate. This move towards more personalised medicine is supported by a clinical guideline published in 2018. Finally, a comprehensive management programme is strongly recommended for all patients with multiple sclerosis, enhancing health-related quality of life through advocating wellness, addressing aggravating factors, and managing comorbidities. The greatest remaining challenge for multiple sclerosis is the development of treatments incorporating neuroprotection and remyelination to treat and ultimately prevent the disabling, progressive forms of the condition. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Multiple sclerosis

    International Nuclear Information System (INIS)

    Sadashima, Hiromichi; Kusaka, Hirofumi; Imai, Terukuni; Takahashi, Ryosuke; Matsumoto, Sadayuki; Yamamoto, Toru; Yamasaki, Masahiro; Maya, Kiyomi

    1986-01-01

    Eleven patients with a definite diagnosis of multiple sclerosis were examined in terms of correlations between the clinical features and the results of cranial computed tomography (CT), and magnetic resonance imaging (MRI). Results: In 5 of the 11 patients, both CT and MRI demonstrated lesions consistent with a finding of multiple sclerosis. In 3 patients, only MRI demonstrated lesions. In the remaining 3 patients, neither CT nor MRI revealed any lesion in the brain. All 5 patients who showed abnormal findings on both CT and MRI had clinical signs either of cerebral or brainstem - cerebellar lesions. On the other hand, two of the 3 patients with normal CT and MRI findings had optic-nerve and spinal-cord signs. Therefore, our results suggested relatively good correlations between the clinical features, CT, and MRI. MRI revealed cerebral lesions in two of the four patients with clinical signs of only optic-nerve and spinal-cord lesions. MRI demonstrated sclerotic lesions in 3 of the 6 patients whose plaques were not detected by CT. In conclusion, MRI proved to be more helpful in the demonstration of lesions attributable to chronic multiple sclerosis. (author)

  18. Primary Standardization of 152Eu by 4πβ(LS) – γ (Nal) coincidence counting and CIEMAT-NIST method

    Science.gov (United States)

    Ruzzarin, A.; da Cruz, P. A. L.; Ferreira Filho, A. L.; Iwahara, A.

    2018-03-01

    The 4πβ-γ coincidence counting and CIEMAT/NIST liquid scintillation method were used in the standardization of a solution of 152Eu. In CIEMAT/NIST method, measurements were performed in a Liquid Scintillation Counter model Wallac 1414. In the 4πβ-γ coincidence counting, the solution was standardized using a coincidence method with ‘‘beta-efficiency extrapolation”. A simple 4πβ-γ coincidence system was used, with acrylic scintillation cell coupled to two coincident photomultipliers at 180° each other and NaI(Tl) detector. The activity concentrations obtained were 156.934 ± 0.722 and 157.403 ± 0.113 kBq/g, respectively, for CIEMAT/NIST and 4πβ-γ coincidence counting measurement methods.

  19. A tandem time–of–flight spectrometer for negative–ion/positive–ion coincidence measurements with soft x-ray excitation

    Energy Technology Data Exchange (ETDEWEB)

    Stråhlman, Christian, E-mail: Christian.Strahlman@maxlab.lu.se; Sankari, Rami; Nyholm, Ralf [MAX IV Laboratory, Lund University, P.O. Box 118, 22100 Lund (Sweden); Kivimäki, Antti [Consiglio Nazionale delle Ricerche—Istituto Officina dei Materiali, Laboratorio TASC, 34149 Trieste (Italy); Richter, Robert [Elettra–Sincrotrone Trieste, Area Science Park, 34149 Trieste (Italy); Coreno, Marcello [Consiglio Nazionale delle Ricerche—Istituto di Struttura della Materia, 34149 Trieste (Italy)

    2016-01-15

    We present a newly constructed spectrometer for negative–ion/positive–ion coincidence spectroscopy of gaseous samples. The instrument consists of two time–of–flight ion spectrometers and a magnetic momentum filter for deflection of electrons. The instrument can measure double and triple coincidences between mass–resolved negative and positive ions with high detection efficiency. First results include identification of several negative–ion/positive–ion coincidence channels following inner-shell photoexcitation of sulfur hexafluoride (SF{sub 6})

  20. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, Egon; Stenager, E N; Knudsen, Lone

    1994-01-01

    In a cross-sectional study of 117 randomly selected patients (52 men, 65 women) with definite multiple sclerosis, it was found that 76 percent were married or cohabitant, 8 percent divorced. Social contacts remained unchanged for 70 percent, but outgoing social contacts were reduced for 45 percent....... Ninety-five percent lived in own house or flat and 70 percent received disablement pension. More than half of the patients (56.4 percent) were dependent on help from close relatives, most frequently spouse. The need for help, the risk of divorce, loss of contact with relatives, difficulty in going out...

  1. The Rationale of Crisis Management – On the Handling of Coincidence in Economic Situation

    Directory of Open Access Journals (Sweden)

    Peter Bendixen

    2010-07-01

    Full Text Available The subject of this essay is too complex a problem as to cover all details in depth and, thus, draws its attention only to core aspects of the handling of coincidence leaving out sophisticated studies and analytic findings as well as detailed reference to economic literature though there is not very much. On the other hand, for a lot of actual as well as general reasons, the subject is too important a matter as to ignore the serious methodological problems of crisis management, which are rooted in some politically still active bias hidden in orthodox neo-classical economics (Stiglitz 2010. If crisis management continues to follow traditional rationales, it will fail realizing the increasing dynamic of crises within the globalising economies of the world. No existing economy can be considered as an isolated system of its own embedded in a stable composition of societal surroundings. Obviously, many a critical situation has its origin in the sphere of civilization, of political discrepancies, and of administrative inflexibilities. On the other hand, any grave amplitude of markets would touch the entire social surrounding. The belief in the markets’ strength of self-regulation is a dangerous construction of orthodox economics (Bendixen 2009b, 2010. The view on crises suggested here is that of a holistic approach to understand a critical situation. Any interpretation of a situation includes empirical dates and figures based on analytic research, but solving a problem is not an act of logical derivation from findings, as if a solution can be excavated in the mud of reality by empirical studies only. Empirical figures report events of the past; the future does not reveal any empiricism. This would be a contradiction in itself. The end of a crisis as well as the search for solutions to fight the problems revealed is unavoidably a view into the future. Therefore, the rationale of crisis management cannot be made of pure empiricism but should include a

  2. The supermassive black hole coincident with the luminous transient ASASSN-15lh

    Science.gov (United States)

    Krühler, T.; Fraser, M.; Leloudas, G.; Schulze, S.; Stone, N. C.; van Velzen, S.; Amorin, R.; Hjorth, J.; Jonker, P. G.; Kann, D. A.; Kim, S.; Kuncarayakti, H.; Mehner, A.; Nicuesa Guelbenzu, A.

    2018-02-01

    The progenitors of astronomical transients are linked to a specific stellar population and galactic environment, and observing their host galaxies hence constrains the physical nature of the transient itself. Here, we use imaging from the Hubble Space Telescope, and spatially resolved, medium-resolution spectroscopy from the Very Large Telescope obtained with X-shooter and MUSE to study the host of the very luminous transient ASASSN-15lh. The dominant stellar population at the transient site is old (around 1 to 2 Gyr) without signs of recent star formation. We also detect emission from ionized gas, originating from three different, time invariable, narrow components of collisionally excited metal and Balmer lines. The ratios of emission lines in the Baldwin-Phillips-Terlevich diagnostic diagram indicate that the ionization source is a weak active galactic nucleus with a black hole mass of M• = 5-3+8 × 108 M⊙, derived through the M•-σ relation. The narrow line components show spatial and velocity offsets on scales of 1 kpc and 500 km s-1, respectively; these offsets are best explained by gas kinematics in the narrow-line region. The location of the central component, which we argue is also the position of the supermassive black hole, aligns with that of the transient within an uncertainty of 170 pc. Using this positional coincidence as well as other similarities with the hosts of tidal disruption events, we strengthen the argument that the transient emission observed as ASASSN-15lh is related to the disruption of a star around a supermassive black hole, most probably spinning with a Kerr parameter a• ≳ 0.5. Based on observations at ESO, Program IDs: 097.D-1054, 297.B-5035, 099.D-0115.The data used in this manuscript are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/610/A14

  3. Abrupt hydroclimate disruption across the Australian arid zone 50 ka coincident with human colonization

    Science.gov (United States)

    Miller, G. H.; Fogel, M. L.; Magee, J. W.; Gagan, M. K.

    2016-12-01

    Although many studies focus on how climate change impacted ancient societies, in Australia a growing body of evidence indicates that activities of the earliest human colonizers in turn altered the Australian climate. We utilize the stable isotopes of carbon and oxygen preserved in near-continuous 100 ka time series of avian eggshell from five regions across the Australian arid zone to reconstruct ecosystem status (d13C) and effective moisture (d18O). Training sets of sub-modern samples provide the basis for the reconstructions. Together, d13C and d18O provide independent estimates of ecosystem status and climate over the past 100 ka from the same dated sample, reducing correlation uncertainties between proxies. Changes in eggshell d13C document a dramatic reduction of palatable summer-wet C4 grasses in all regions between 50 and 45 ka, that has persisted through to modern times. Continuous 100 ka records of effective moisture derived from eggshell d18O show moist conditions from 100 to 60 ka, with variable drying after 60 ka, but the strong shift toward greatest aridity is coincident with the onset of the last glacial maximum 30 ka ago, 15 ka after the observed ecosystem restructuring. Combining the d13C and d18O time-series shows that an abrupt and permanent restructuring of the moisture/ecosystem balance occurred between 50 and 45 ka. Additional studies show that most large monsoon-fed inland arid-zone lakes carried permanent water at least intermittently between 120 and 50 ka, but never experienced permanent deep-water status after 45 ka, despite a wide range of global climate states, including the early Holocene when most other monsoon systems were reinvigorated. The lack of exceptional climate shifts either locally or globally between 60 and 40 ka eliminates climate as the cause of the ecosystem restructuring and persistent lake desiccation. Collectively these data suggest the wave of human colonization across Australia in altered land surface characteristics

  4. A first search for coincident gravitational waves and high energy neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Di Palma, Irene

    2012-08-14

    We present the results of the first search for gravitational wave (GW) bursts associated with high energy neutrinos (HEN), detected by the underwater neutrino telescope ANTARES in its 5 lines configuration, during the fifth LIGO science run and first Virgo science run. The data used in this analysis were collected from February 9 to September 30 2007. Cataclysmic cosmic events with burst activity can be plausible sources of concomitant GW and HEN. Such messengers could reveal new, hidden sources that are not observed by conventional photon astronomy, in particular at high energy. In a first stage of the analysis, HEN candidates, detected during the operation of the ANTARES Telescope were selected. In a second stage, GW candidates in time and space correlation with the HEN events were searched for in LIGO and Virgo data. During this first joint GW+HEN search, no coincident event was observed. We set limits on the population density of different types of concurrent GW-HEN sources. For short GRB-like sources, related to the merger of two compact objects, the density upper limit is {rho}{sub GW-HEN}{sup SGRB}

  5. Design of an electronic system with simultaneous registering of pulse amplitude and event time applied to the 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Toledo, Fabio de

    2009-01-01

    The 4πβ-γ coincidence method for absolute radionuclide activity measurement has been considered for many years as a primary standard in Nuclear Metrology, because of dependence on few observable quantities and high accuracy. The Laboratorio de Metrologia Nuclear (LMN) - Nuclear Metrology Laboratory -, at Instituto de Pesquisas Energeticas e Nucleares (IPEN) - Nuclear and Energy Research Institute -, among its measurement techniques, uses the 4πβ-γ coincidence method. Recently a new technique known as 'software coincidence' has been used, with many advantages over the conventional coincidence methodology. In order to update the methodologies for radionuclide standardizations, the LMN developed a new system based on the software coincidence technique, described in the present work. This system uses the same nuclear set up for beta and gamma detection. The new software coincidence electronics uses a National Instruments (NI) acquisition card connected to a microcomputer and, through a connection panel, to the nuclear detection set up. The card configuration and controlling is accomplished by software using the LabVIEW, a NI proprietary product. This system records into disk files all the amplitudes and occurrence times for beta and gamma detected pulses. A suitable software was developed (the coincidence analysis program) to process the recorded data in order to obtain beta, gamma and coincidence counts and perform calculation of the radioactive source activity. The work also presents and discusses the results obtained with the first version of the coincidence analysis program, as well as perspectives for future works. (author)

  6. [Multiple myeloma].

    Science.gov (United States)

    Abe, Masahiro; Miki, Hirokazu; Nakamura, Shingen

    2016-03-01

    Owing to the positive clinical benefits obtained with new agents, complete remission (CR) can be used as a surrogate for overall survival, and should be achieved. Although multiple myeloma is a heterogeneous disease in terms of myeloma cell- and patient-related risk factors, patients should receive the most effective combination therapy based on proteasome inhibitors and/or immunomodulatory drugs (IMiDs) as backbone medication irrespective of the risks encountered in the setting of induction therapy ("one-size-fits-all" therapy), followed by consolidation/maintenance therapy to achieve CR with the ultimate goal of extended survival. Myeloma-defining biomarkers have been established to identify high-risk smoldering myeloma requiring treatment. The development of salvage treatments yielding better outcomes for relapsed/refractory myeloma is urgently needed. Upcoming novel molecular targeting agents with different modes of action and immunotherapeutic agents will be integrated into myeloma treatment regimens with a great therapeutic impact, and further evolution of the treatment paradigm for multiple myeloma is eagerly anticipated.

  7. Multiple inflation

    International Nuclear Information System (INIS)

    Murphy, P.J.

    1987-01-01

    The Theory of Inflation, namely, that at some point the entropy content of the universe was greatly increased, has much promise. It may solve the puzzles of homogeneity and the creation of structure. However, no particle physics model has yet been found that can successfully drive inflation. The difficulty in satisfying the constraint that the isotropy of the microwave background places on the effective potential of prospective models is immense. In this work we have codified the requirements of such models in a most general form. We have carefully calculated the amounts of inflation the various problems of the Standard Model need for their solution. We have derived a completely model independent upper bond on the inflationary Hubble parameter. We have developed a general notation with which to probe the possibilities of Multiple Inflation. We have shown that only in very unlikely circumstances will any evidence of an earlier inflation, survive the de Sitter period of its successor. In particular, it is demonstrated that it is most unlikely that two bouts of inflation will yield high amplitudes of density perturbations on small scales and low amplitudes on large. We conclude that, while multiple inflation will be of great theoretical interest, it is unlikely to have any observational impact

  8. Coincidence of flowering time and the productivity and quality of cauliflower hybrid seeds Coincidência de florescimento entre linhagens de couve-flor na produtividade e qualidade de sementes híbridas

    Directory of Open Access Journals (Sweden)

    Marcelo Fontanetti Verdial

    2001-09-01

    Full Text Available The missing of flowering synchronization between the self-incompatible lines in a crop field of cauliflower hybrid seeds besides making the seed production smaller can compromise the genetic purity of them. The coincidence of the flowering time between two cauliflower lines was examined to study its effect on the productivity and quality of hybrid seeds. The treatments consisted of six different sowing dates, every fifteen days, using a self-incompatible tropical line pollinated by a winter line which does not present self-incompatibility. The following characteristics were evaluated: leaf average area and number of flowers per plant, number of siliques per plant, number and weight of seeds per plant, weight of thousand seeds and average number of seeds per silique. The germination standard test and genetic seed purity were determined for each treatment. The coincident flowering season between cauliflower lines affects directly the productivity and the genetic quality of the produced hybrid seeds. The closer the flowering time coincidence between the lines, the greater the number of seeds per silique and the smaller the percentage of non-hybrid seedlings. However, the coincidence of the flowering season between lines was found to influence physiological seed quality.A falta de sincronismo de florescimento entre as linhagens auto incompatíveis em um campo de produção de sementes híbridas de couve flor pode além de reduzir a produção de sementes comprometer a pureza genética das mesmas. Com o objetivo de estudar o efeito da coincidência de florescimento entre linhagens de couve-flor na produtividade e qualidade de sementes híbridas, foi realizado o presente experimento. Os tratamentos consistiram em seis diferentes épocas de semeadura, espaçadas a cada quinze dias, de uma linhagem de verão auto-incompatível que foi polinizada por uma linhagem de inverno que não apresenta auto-incompatibilidade. Observou-se a coincidência do

  9. Realisation of a {beta} spectrometer solenoidal and a double {beta} spectrometer at coincidence; Realisation d'un spectrometre {beta} solenoidal et d'un double spectrometre {beta} a coincidence

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-06-15

    The two spectrometers have been achieved to tackle numerous problems of nuclear spectrometry. They possess different fields of application that complete themselves. The solenoidal spectrometer permits the determination of the energy limits of {beta} spectra and of their shape; it also permits the determination of the coefficients of internal conversion and reports {alpha}{sub K} / {alpha}{sub L} and it is especially efficient for the accurate energy levels of the {gamma} rays by photoelectric effect. The double coincidence spectrometer has been conceived to get a good efficiency in coincidence: indeed, the sum of the solid angles used for the {beta} and {gamma} emission is rather little lower to 4{pi} steradians. To get this efficiency, one should have sacrificed a little the resolution that is lower to the one obtained with the solenoidal spectrometer for a same brightness. Each of the elements of the double spectrometer can also be adapted to the study of angular correlations {beta}{gamma} and e{sup -}{gamma}. In this use, it is superior to the thin magnetic lens used up to here. The double spectrometer also permits the survey of the coincidences e{sup -}e{sup -}, e{sup -}{beta} of a equivalent way to a double lens; it can also be consider some adaptation for the survey of the angular correlations e{sup -}e{sup -}, e{sup -}{beta}. Finally, we applied the methods by simple spectrometry and by coincidence spectrometry, to the study of the radiances of the following radioelements: {sup 76}As (26 h), {sup 122}Sb (2,8 j), {sup 124}Sb (60 j), {sup 125}Sb (2,7 years). (M.B.) [French] Les deux spectrometres qui ont ete realises permettent d'aborder un grand nombre de problemes de spectrometrie nucleaire. Ils possedent des champs d'application tres differents qui se completent. Le spectrometre solenoidal permet la determination des energies limites des spectres {beta} et de leur forme; il permet aussi la determination des coefficients de conversion interne et

  10. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Knudsen, L; Jensen, K

    1994-01-01

    a significant correlation between results of an attention and perceptual motor speed test i.e. Symbol Digit Modalities test and the ability to read TV-subtitles, but no correlation was found with another attention and perceptual motor speed test, or verbal or visual memory. No correlation between the use......In a cross-sectional study of 94 patients (42 males, 52 females) with definite multiple sclerosis (MS) in the age range 25-55 years, the correlation of neuropsychological tests with the ability to read TV-subtitles and with the use of sedatives is examined. A logistic regression analysis reveals...... of sedatives and results on neuropsychological tests was found. Anxiety was not correlated with the ability to read TV-subtitles. It is concluded that visual deficits but not the use of sedatives may be a confounding factor in neuropsychological testing in MS....

  11. [Multiple apheresis].

    Science.gov (United States)

    Coffe, C

    2007-05-01

    Multiple apheresis makes it possible to obtain at least two labile blood components from a single donor using a cell separator. It can be either multicomponent apheresis leading to the preparation of at least two different blood component types or red blood cell apheresis providing two identical red blood cell concentrates. These techniques available in addition to whole blood donation, are modifying collection strategies in many Etablissements Français du Sang and will contribute to improve stock logistics in the future. In areas with insufficient stock, these procedures will help achieve blood component self-sufficiency. The author first describes the principle underlying different--current or future--techniques as well as their advantages and drawbacks. He finally addresses the potential impact of these processes on the evolution of blood collection and the advantages to be gained.

  12. An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements.

    Science.gov (United States)

    Joseph, Leena; Das, A P; Ravindra, Anuradha; Kulkarni, D B; Kulkarni, M S

    2018-03-06

    4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Copyright © 2018. Published by Elsevier Ltd.

  13. Detection of helium in irradiated Fe9Cr alloys by coincidence Doppler broadening of slow positron annihilation

    Science.gov (United States)

    Cao, Xingzhong; Zhu, Te; Jin, Shuoxue; Kuang, Peng; Zhang, Peng; Lu, Eryang; Gong, Yihao; Guo, Liping; Wang, Baoyi

    2017-03-01

    An element analysis method, coincidence Doppler broadening spectroscopy of slow positron annihilation, was employed to detect helium in ion-irradiated Fe9Cr alloys. Spectra with higher peak to background ratio were recorded using a two-HPGe detector coincidence measuring system. It means that information in the high-momentum area of the spectra can be used to identify helium in metals. This identification is not entirely dependent on the helium concentration in the specimens, but is related to the structure and microscopic arrangement of atoms surrounding the positron annihilation site. The results of Doppler broadening spectroscopy and transmission electron microscopy show that vacancies and dislocations were formed in ion-irradiated specimens. Thermal helium desorption spectrometry was performed to obtain the types of He traps.

  14. Alpha and conversion electron spectroscopy of 238,239Pu and 241Am and alpha-conversion electron coincidence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Dion, Michael P.; Miller, Brian W.; Warren, Glen A.

    2016-09-01

    A technique to determine the isotopics of a mixed actinide sample has been proposed by measuring the coincidence of the alpha particle during radioactive decay with the conversion electron (or Auger) emitted during the relaxation of the daughter isotope. This presents a unique signature to allow the deconvolution of isotopes that possess overlapping alpha particle energy. The work presented here are results of conversion electron spectroscopy of 241Am, 238Pu and 239Pu using a dual-stage peltier-cooled 25 mm2 silicon drift detector. A passivated ion implanted planar silicon detector provided measurements of alpha spectroscopy. The conversion electron spectra were evaluated from 20–55 keV based on fits to the dominant conversion electron emissions, which allowed the relative conversion electron emission intensities to be determined. These measurements provide crucial singles spectral information to aid in the coincident measurement approach.

  15. Detection in coincidence of gravitational wave bursts with a network of interferometric detectors: Geometric acceptance and timing

    International Nuclear Information System (INIS)

    Arnaud, Nicolas; Barsuglia, Matteo; Bizouard, Marie-Anne; Canitrot, Philippe; Cavalier, Fabien; Davier, Michel; Hello, Patrice; Pradier, Thierry

    2002-01-01

    Detecting gravitational wave bursts (characterized by short durations and poorly modeled waveforms) requires coincidences between several interferometric detectors in order to reject nonstationary noise events. As the wave amplitude seen in a detector depends on its location with respect to the source direction and as the signal to noise ratio of these bursts is expected to be low, coincidences between antennas may not be very likely. This paper investigates this question from a statistical point of view by using a simple model of a network of detectors; it also estimates the timing precision of a detection in an interferometer, which is an important issue for the reconstruction of the source location based on time delays

  16. An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Weihua Zhang

    2011-01-01

    Full Text Available An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404 embedded in a CsI(Tl crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.

  17. Coincidence theory: Seeking a perceptual preference for just intonation, equal temperament, and Pythagorean intonation in excerpts for wind instruments

    Science.gov (United States)

    Long, Derle Ray

    Coincidence theory states that when the components of harmony are in enhanced alignment the sound will be more consonant to the human auditory system. An objective method of examining the components of harmony is by investigating alignment of the mathematics of a particular sound or harmony. The study examined preference responses to excerpts tuned in just intonation, Pythagorean intonation, and equal temperament. Musical excerpts were presented in pairs and study subjects simply picked one version from the pair that they perceived as the most consonant. Results of the study revealed an overall preference for equal temperament in contradiction to coincidence theory. Several additional areas for research are suggested to further investigate the results of this study.

  18. The influence of radiation and light on Ps formation in PMMA and PE studied by coincidence Doppler-broadening spectroscopy

    CERN Document Server

    Suzuki, T; Shantarovich, V; Kondo, K; Hamada, E; Matso, M; Ma Li; Ito, Y

    2003-01-01

    Using two Ge detectors, the high-resolution Doppler-broadening energy spectra of positron annihilation gamma rays has been obtained by measuring the coincidences of the two photons. Light bleaching and oxygen effects on positron annihilation were investigated in this way. A large enhancement of the high-momentum part of the coincidence Doppler spectra was observed in poly(methylmethacrylate) (PMMA), which contains oxygen atoms in the polymer structure. Bleaching experiments in PMMA and in copolymer ethylene-methylmethacrylate EMMA (LDPE+MMA 3 mol%) have demonstrated that the enhancement effect may be due to the trapping of positrons by the polar -C sup + 6-O sup - groups, followed by positron annihilation with the electrons belonging to oxygen.

  19. Activity determination of a {sup 201}Tl solution by 4πβ-γ and sum-peak coincidence methods

    Energy Technology Data Exchange (ETDEWEB)

    Ruzzarin, Anelise; Lopes, Ricardo Tadeu, E-mail: aruzzarin@nuclear.ufrj.br [Coordenacao dos Cursos de Pos-Graduacao em Engenharia (LIN/PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear. Lab. de Instrumentacao Nuclear; Silva, Monica A. L. da [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Iwahara, Akira; Silva, Ronaldo L. da; Filho, Octavio L.T.; Poledna, Roberto [Instituto de Radioprotecao e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes

    2015-07-01

    {sup 201}Tl is used in nuclear medicine in cardiac imaging for evaluating the injury level in cardiac muscle at rest and exercise. In this work the activity concentration of a {sup 201}Tl radioactive solution has been absolutely determined using the 4πβ-γ coincidence and sum-peak coincidence methods. The presence of {sup 202}Tl radioactive impurity that imposes some difficult in the activity measurements was taken into account in the measurements. In the sum-peak method a planar germanium detector was used. The half-lives were evaluated by the reference source method and the results obtained were (3.033 ± 0.004) d and (12.320 ± 0.163) d, respectively, for {sup 201}Tl and {sup 202}Tl. (author)

  20. Standardization of 68Ge-68Ga using 4πβ(LS)-γ coincidence counting system for activity measurements.

    Science.gov (United States)

    Kulkarni, D B; Joseph, Leena; Anuradha, R; Kulkarni, M S; Tomar, B S

    2017-05-01

    68 Ga has great scope for use in future for positron emission tomography (PET) imaging due to its very fast blood clearance and fast target localization, even though at present 18 F is widely used. 68 Ge in equilibrium with 68 Ga ( 68 Ge- 68 Ga) can also be used as a surrogate for 18 F calibration, as 18 F source standardization can be done at national metrology institute (NMI) but, these standards cannot be sent to nuclear medicine centers (NMCs) across India for calibration of isotope calibrators, due to the short half-life of 18 F (110min). Providing 68 Ge- 68 Ga standards to NMCs requires that first standardization must be carried out at NMI (BARC in India) to provide traceability to the measurements carried out at NMCs. In the present work, standardization of 68 Ge- 68 Ga was carried out using 4πβ(LS)-γ coincidence counting system and CIEMAT/NIST efficiency tracing technique. The decay scheme correction factors for two gamma windows were calculated by Monte Carlo technique using general purpose code FLUKA. The activity concentration values were normalized by the activity concentration obtained by 4πβ(LS)-γ coincidence counting system using window-1. The final result reported to BIPM for 4πβ(LS)-γ coincidence counting was calculated by taking arithmetic mean of activity concentrations obtained for two gamma windows. The normalized activity concentration obtained by 4πβ(LS)-γ coincidence counting was 0.998±0.005 and that obtained using CIEMAT/NIST efficiency tracing was 1.002±0.007 which are in excellent agreement within uncertainty limits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. (e,e'f) coincidence experiments for fission decay of giant resonances in 235,238U

    International Nuclear Information System (INIS)

    Weber, T.; Heil, R.D.; Kneissl, U.; Pecho, W.; Wilke, W.; Emrich, H.J.; Kihm, T.; Knoepfle, K.T.

    1988-01-01

    Extending previous work on 238 U, 235 U(e,e'f) coincidence data were taken at 4 momentum transfers yielding both E1, E2/E0 and E3 form factors and the respective multipole strength distributions in the giant resonance region of 238 U (4 x x /Γ a is obtained as a function of excitation energy for separated multipoles. The giant E2 resonance exhibits an increased symmetric fission contribution compared to E1 and E3 resonances. (orig.)

  2. Development of liquid scintillation based 4πβ(LS)-γ coincidence counting system and demonstration of its performance by standardization of ⁶⁰Co.

    Science.gov (United States)

    Kulkarni, D B; Anuradha, R; Joseph, Leena; Tomar, B S

    2013-02-01

    A single-vial, single-PMT 4πβ(LS)-γ coincidence counting system has been developed at the Radiation Safety Systems Division, BARC. It has advantages of simple sample preparation, higher counting efficiency and the absence of self absorption over the conventional proportional counter based 4πβ(PC)-γ coincidence counting system. The performance of the system is demonstrated by standardizing a (60)Co solution using the 4πβ(LS)-γ coincidence counting system, 4πβ(PC)-γ coincidence counting system and CIEMAT/NIST method and comparing the results obtained by each method. The detection efficiency of liquid scintillation counter of the 4πβ(LS)-γ coincidence counting system was varied by color quenching, by chemical quenching and by varying the bias voltage applied to the LSC PMT. For the proportional counter based 4πβ(PC)-γ coincidence counting system the detection efficiency was varied by source self absorption. The activity concentrations obtained using the 4πβ(LS)-γ coincidence counting system, the 4πβ(PC)-γ coincidence counting system and the CIEMAT/NIST method are comparable within the uncertainty limits. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. {sup 18}F-FDG for the staging of patients with differentiated thyroid cancer. Comparison of a dual-head coincidence gamma camera with dedicated PET

    Energy Technology Data Exchange (ETDEWEB)

    Tiepolt, C.; Beuthien-Baumann, B.; Hliscs, R.; Bredow, J.; Kuehne, A.; Kropp, J.; Burchert, W.; Franke, W. [Univ. of Dresden (Germany). Carl Gustav Carus Medical School

    2000-10-01

    Coincidence imaging with a dual-head gamma camera may offer a cost-effective alternative to dedicated PET. The aim of this study was to compare the diagnostic accuracy of coincidence imaging and PET in patients with differentiated thyroid cancer. Thirty-one patients were studied after thyroidectomy and radioiodine ablation. They were injected with a single dose of 300 MBq {sup 18}F-fluorodeoxyglucose (FDG). Scanning was performed on a dedicated PET system after 1 hr, and on a coincidence gamma camera after 4 hrs. Based on a lesion-by-lesion comparison, coincidence imaging and PET concurred in 69% of 118 lesions. Based on lesions size, concurrence was 96% in lesions larger than 1.5 cm, and 62% in those between 1 and 1.5 cm. Lesions smaller than 1 cm could not be identified with coincidence imaging. Identical staging was obtained with coincidence imaging and PET in 26/31 patients (84%). In four patients FDG accumulating lesions were shown by both the coincidence camera and the dedicated scanner, but not detectable with any other imaging means and were confirmed histologically on surgery. Although a coincidence camera is technically inferior to a dedicated PET scanner, it may provide clinically useful results in situations were a lesion of sufficient size and FDG uptake is to be expected, e.g. when evaluating a known lesion for malignancy. (author)

  4. Phylogenetic relationships among extant classes of echinoderms, as inferred from sequences of 18S rDNA, coincide with relationships deduced from the fossil record.

    Science.gov (United States)

    Wada, H; Satoh, N

    1994-01-01

    In spite of the rich fossil record and multiple descriptions of morphological and embryological characteristics, the origin and subsequent evolution of echinoderms remain highly controversial issues. Using sequence data derived from 18S rDNA, we have investigated the phylogenetic relationships among five extant classes of echinoderms--namely, crinoids, asteroids, ophiuroids, echinoids, and holothurians. Almost complete sequences of 18S rDNA were determined for one species in each class, and phylogenetic trees were constructed both by the neighbor-joining method and by the maximum-likelihood method, with a hemichordate as an outgroup. The trees constructed by these methods support the hypothesis that the phylum Echinodermata can be subdivided into two subphyla, Pelmatozoa and Eleutherozoa. The class Holothuroidea, which has been the subject of debate with respect to whether the members are primitive or advanced echinoderms, did not occupy a primitive position but had an affinity for the class Echinoidea. Since both trees gave different branching topologies for the order of emergence of asteroids and ophiuroids, it seems likely that these two groups emerged within a very short period of time. A rough estimate of the timing of the divergence of the five classes from the present molecular analysis coincided with that deduced from the fossil record.

  5. An overview of the web-based Google Earth coincident imaging tool

    Science.gov (United States)

    Chander, Gyanesh; Kilough, B.; Gowda, S.

    2010-01-01

    The Committee on Earth Observing Satellites (CEOS) Visualization Environment (COVE) tool is a browser-based application that leverages Google Earth web to display satellite sensor coverage areas. The analysis tool can also be used to identify near simultaneous surface observation locations for two or more satellites. The National Aeronautics and Space Administration (NASA) CEOS System Engineering Office (SEO) worked with the CEOS Working Group on Calibration and Validation (WGCV) to develop the COVE tool. The CEOS member organizations are currently operating and planning hundreds of Earth Observation (EO) satellites. Standard cross-comparison exercises between multiple sensors to compare near-simultaneous surface observations and to identify corresponding image pairs are time-consuming and labor-intensive. COVE is a suite of tools that have been developed to make such tasks easier.

  6. Development of liquid scintillation based 4πβ(LS)-γ coincidence counting system and demonstration of its performance by standardization of 60Co

    International Nuclear Information System (INIS)

    Kulkarni, D.B.; Anuradha, R.; Joseph, Leena; Tomar, B.S.

    2013-01-01

    A single-vial, single-PMT 4πβ(LS)-γ coincidence counting system has been developed at the Radiation Safety Systems Division, BARC. It has advantages of simple sample preparation, higher counting efficiency and the absence of self absorption over the conventional proportional counter based 4πβ(PC)-γ coincidence counting system. The performance of the system is demonstrated by standardizing a 60 Co solution using the 4πβ(LS)-γ coincidence counting system, 4πβ(PC)-γ coincidence counting system and CIEMAT/NIST method and comparing the results obtained by each method. The detection efficiency of liquid scintillation counter of the 4πβ(LS)-γ coincidence counting system was varied by color quenching, by chemical quenching and by varying the bias voltage applied to the LSC PMT. For the proportional counter based 4πβ(PC)-γ coincidence counting system the detection efficiency was varied by source self absorption. The activity concentrations obtained using the 4πβ(LS)-γ coincidence counting system, the 4πβ(PC)-γ coincidence counting system and the CIEMAT/NIST method are comparable within the uncertainty limits. - Highlights: ► A 4πβ(LS)-γ coincidence counting system has been developed in the laboratory. ► The performance of the system is demonstrated by standardizing a 60 Co solution. ► Three methods viz. 4πβ(LS)-γ, 4πβ(PC)-γ coincidence counting system, and CIEMAT/NIST method are used. ► The activity concentrations obtained by different methods are comparable within uncertainty limits.

  7. Cytoplasmic localization of Hug1p, a negative regulator of the MEC1 pathway, coincides with the compartmentalization of Rnr2p–Rnr4p

    International Nuclear Information System (INIS)

    Ainsworth, William B.; Hughes, Bridget Todd; Au, Wei Chun; Sakelaris, Sally; Kerscher, Oliver; Benton, Michael G.; Basrai, Munira A.

    2013-01-01

    Highlights: •Hug1p overexpression sensitizes wild-type cells to DNA damage and hydroxyurea (HU). •Expression of Hug1p in response to HU treatment is delayed relative to Rnr3p. •MEC1 pathway genes are required for cytoplasmic localization of Hug1p. •Hug1p subcellular compartmentalization to the cytoplasm coincides with Rnr2p–Rnr4p. -- Abstract: The evolutionarily conserved MEC1 checkpoint pathway mediates cell cycle arrest and induction of genes including the RNR (Ribonucleotide reductase) genes and HUG1 (Hydroxyurea, ultraviolet, and gamma radiation) in response to DNA damage and replication arrest. Rnr complex activity is in part controlled by cytoplasmic localization of the Rnr2p–Rnr4p subunits and inactivation of negative regulators Sml1p and Dif1p upon DNA damage and hydroxyurea (HU) treatment. We previously showed that a deletion of HUG1 rescues lethality of mec1Δ and suppresses dun1Δ strains. In this study, multiple approaches demonstrate the regulatory response of Hug1p to DNA damage and HU treatment and support its role as a negative effector of the MEC1 pathway. Consistent with our hypothesis, wild-type cells are sensitive to DNA damage and HU when HUG1 is overexpressed. A Hug1 polyclonal antiserum reveals that HUG1 encodes a protein in budding yeast and its MEC1-dependent expression is delayed compared to the rapid induction of Rnr3p in response to HU treatment. Cell biology and subcellular fractionation experiments show localization of Hug1p-GFP to the cytoplasm upon HU treatment. The cytoplasmic localization of Hug1p-GFP is dependent on MEC1 pathway genes and coincides with the cytoplasmic localization of Rnr2p–Rnr4p. Taken together, the genetic interactions, gene expression, and localization studies support a novel role for Hug1p as a negative regulator of the MEC1 checkpoint response through its compartmentalization with Rnr2p–Rnr4p

  8. Cytoplasmic localization of Hug1p, a negative regulator of the MEC1 pathway, coincides with the compartmentalization of Rnr2p–Rnr4p

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, William B. [Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803 (United States); Hughes, Bridget Todd; Au, Wei Chun; Sakelaris, Sally [Genetics Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Kerscher, Oliver [Biology Department, The College of William and Mary, Williamsburg, VA 23185 (United States); Benton, Michael G., E-mail: benton@lsu.edu [Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803 (United States); Basrai, Munira A., E-mail: basraim@mail.nih.gov [Genetics Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States)

    2013-10-04

    Highlights: •Hug1p overexpression sensitizes wild-type cells to DNA damage and hydroxyurea (HU). •Expression of Hug1p in response to HU treatment is delayed relative to Rnr3p. •MEC1 pathway genes are required for cytoplasmic localization of Hug1p. •Hug1p subcellular compartmentalization to the cytoplasm coincides with Rnr2p–Rnr4p. -- Abstract: The evolutionarily conserved MEC1 checkpoint pathway mediates cell cycle arrest and induction of genes including the RNR (Ribonucleotide reductase) genes and HUG1 (Hydroxyurea, ultraviolet, and gamma radiation) in response to DNA damage and replication arrest. Rnr complex activity is in part controlled by cytoplasmic localization of the Rnr2p–Rnr4p subunits and inactivation of negative regulators Sml1p and Dif1p upon DNA damage and hydroxyurea (HU) treatment. We previously showed that a deletion of HUG1 rescues lethality of mec1Δ and suppresses dun1Δ strains. In this study, multiple approaches demonstrate the regulatory response of Hug1p to DNA damage and HU treatment and support its role as a negative effector of the MEC1 pathway. Consistent with our hypothesis, wild-type cells are sensitive to DNA damage and HU when HUG1 is overexpressed. A Hug1 polyclonal antiserum reveals that HUG1 encodes a protein in budding yeast and its MEC1-dependent expression is delayed compared to the rapid induction of Rnr3p in response to HU treatment. Cell biology and subcellular fractionation experiments show localization of Hug1p-GFP to the cytoplasm upon HU treatment. The cytoplasmic localization of Hug1p-GFP is dependent on MEC1 pathway genes and coincides with the cytoplasmic localization of Rnr2p–Rnr4p. Taken together, the genetic interactions, gene expression, and localization studies support a novel role for Hug1p as a negative regulator of the MEC1 checkpoint response through its compartmentalization with Rnr2p–Rnr4p.

  9. Positron annihilation in polypropylene studied by lifetime and coincidence Doppler-broadening spectroscopy[Positron annihilation; Doppler broadening; Coincidence Doppler system; PP; Antioxidant; Carbonyl group; Irradiation effect; Core electrons

    Energy Technology Data Exchange (ETDEWEB)

    Djourelov, N. E-mail: nikdjour@post.kek.jp; He, C.; Suzuki, T.; Shantarovich, V.P.; Ito, Y.; Kondo, K.; Ito, Y

    2003-12-01

    The momentum density distributions (MDDs) of electrons taking part in the annihilation processes in polypropylene (PP) have been measured by coincidence Doppler-broadening spectroscopy. MDDs at the beginning of measurements to those at the saturation level of Ps formation have been compared in order to follow the possible changes in concentration of carbonyl groups (CG). A high initial CG concentration in PP has been observed, while for antioxidant-containing PP no significant presence of CG has been detected, and no changes have been observed during positron irradiation.

  10. Restoration of. gamma. -ray multiplicity distributions from experiments with low efficiency multiplicity filters

    Energy Technology Data Exchange (ETDEWEB)

    Bellia, G.; Del Zoppo, A.; Migneco, E.; Russo, G. (Catania Univ. (Italy). Ist. di Fisica; Istituto Nazionale di Fisica Nucleare, Catania (Italy). Lab. del Sud)

    1984-10-01

    The restoration of ..gamma..-ray multiplicity distributions from experimental p-fold coincidence distributions is discussed. It is shown that the restoration of the multiplicity from measurements with low total detection efficiency is an 'incorrectly posed problem'. While in the literature the analysis of the experimental data has been attempted only in terms of the lowest central moments of the multiplicity distribution, in this paper an unfolding method based on the minimization of the directioned discrepancies in the probability space is used. The method is found to work very well even if the total efficiency ..cap omega.. <= 0.1. Realistic tests and a comparison with the usual method of analysis are presented.

  11. Restoration of γ-ray multiplicity distributions from experiments with low efficiency multiplicity filters

    International Nuclear Information System (INIS)

    Bellia, G.; Del Zoppo, A.; Migneco, E.; Russo, G.; Istituto Nazionale di Fisica Nucleare, Catania

    1984-01-01

    The restoration of γ-ray multiplicity distributions from experimental p-fold coincidence distributions is discussed. It is shown that the restoration of the multiplicity from measurements with low total detection efficiency is an 'incorrectly posed problem'. While in the literature the analysis of the experimental data has been attempted only in terms of the lowest central moments of the multiplicity distribution, in this paper an unfolding method based on the minimization of the directioned discrepancies in the probability space is used. The method is found to work very well even if the total efficiency Ω <= 0.1. Realistic tests and a comparison with the usual method of analysis are presented. (orig.)

  12. Gastric Carcinoid and Obesity: Association or Coincidence? Report of Two Cases and Literature Review

    Directory of Open Access Journals (Sweden)

    Obaid Al-Harbi

    2013-01-01

    Full Text Available Bariatric surgery is a prevalent procedure due to the high incidence of obesity and comorbidities. Upper gastrointestinal endoscopy is one of the procedures used to evaluate the patient before surgery. However, its role is questionable. The incidental findings during endoscopy are variable including inflammatory diseases, and ulcers, and epithelial and stromal tumors. Herein a report of two obese sisters with incidental gastric carcinoids was diagnosed in prebariatric surgery endoscopy. Case Summary. 35- and 41-year-old female patients presented with obesity and BMI of 102 and 46 kg/m2, respectively. Both patients underwent upper gastrointestinal endoscopy as part of presurgical evaluation. Multiple polyps were indentified in both patients, and biopsy was taken. Histological examination revealed tumors that were formed by nests of epithelial cells. The cells have eosinophilic cytoplasm and monomorphic nuclei, typical morphology of neuroendocrine tumors. Conclusions. (1 Upper gastrointestinal endoscopy is an important procedure for prebariatric surgery evaluation. (2 Gastric carcinoid is a rare tumor with higher incidence among obese patients.

  13. Concurrent presentation of erythrodermic lichen planus and squamous cell carcinoma: Coincidence or malignant transformation?

    Directory of Open Access Journals (Sweden)

    Neema M Ali

    2015-01-01

    Full Text Available Lichen planus is a common papulosquamous disorder affecting about 1-2% of the population, neoplastic transformation of cutaneous lichen planus lesions occurs very rarely. A 40 year old female patient presented with a 1 year history of developing multiple, itchy, pigmented lesions over both lower legs which gradually spread to involve the whole body. A few tense bullae were seen on the extremities. An erythematous fleshy lesion was seen on the upper aspect of the left buttock. Skin biopsy from a plaque on the right forearm showed features suggestive of lichen planus. Skin biopsy of a bullae showed a sub epidermal bulla filled with a mixed inflammatory infiltrate. Direct immunofluorescence revealed no immunoreactants along the basement membrane zone. A diagnosis of erythrodermic lichen planus with bullous lichen planus was made. Biopsy of fleshy lesion of left buttock revealed a moderately differentiated squamous cell carcinoma. Erythrodermic lichen planus with bullous lesions and secondary squamous cell carcinoma; these occurences in a single patient is extremely rare and has not been previously reported to the best of our knowledge.

  14. Concurrent Presentation of Erythrodermic Lichen Planus and Squamous Cell Carcinoma: Coincidence or Malignant Transformation?

    Science.gov (United States)

    Ali, Neema M; Bhat, Ramesh; Rao, Shwetha B

    2015-01-01

    Lichen planus is a common papulosquamous disorder affecting about 1-2% of the population, neoplastic transformation of cutaneous lichen planus lesions occurs very rarely. A 40 year old female patient presented with a 1 year history of developing multiple, itchy, pigmented lesions over both lower legs which gradually spread to involve the whole body. A few tense bullae were seen on the extremities. An erythematous fleshy lesion was seen on the upper aspect of the left buttock. Skin biopsy from a plaque on the right forearm showed features suggestive of lichen planus. Skin biopsy of a bullae showed a sub epidermal bulla filled with a mixed inflammatory infiltrate. Direct immunofluorescence revealed no immunoreactants along the basement membrane zone. A diagnosis of erythrodermic lichen planus with bullous lichen planus was made. Biopsy of fleshy lesion of left buttock revealed a moderately differentiated squamous cell carcinoma. Erythrodermic lichen planus with bullous lesions and secondary squamous cell carcinoma; these occurences in a single patient is extremely rare and has not been previously reported to the best of our knowledge.

  15. Probability of coincident vaccination in the 24 or 48 hours preceding sudden infant death syndrome death in Australia.

    Science.gov (United States)

    Brotherton, Julia M L; Hull, Brynley P; Hayen, Andrew; Gidding, Heather F; Burgess, Margaret A

    2005-06-01

    Vaccination does not cause sudden infant death syndrome (SIDS). However, SIDS peaks at 2 months of age, when vaccination encounters are frequent. There are no published estimates using population data on age of death and immunization coverage to indicate to practitioners how often coincident vaccination may occur by chance. This study aimed to determine the probability that an Australian infant who has died of SIDS was vaccinated in the days before death. An analytical study of population death data and immunization coverage was conducted for Australian children who were born between April 1, 2002, and March 31, 2003. Also evaluated were Australian children who were registered as dying of SIDS between 1997 and 2001. The main outcomes measured were distribution of SIDS deaths by age and distribution of immunization coverage by age. The probability of recent vaccination and SIDS coinciding varied by age and day of the week of death. The overall estimated probability of vaccination within the last 24 hours for a child who has died of SIDS in Australia is estimated as 1.3%. In the last 48 hours, it is 2.6%. With the average number of SIDS deaths for the period 1997-2001 equal to 130 cases per year, we estimated that a case of SIDS will occur when vaccination was given in the last 24 hours in 1.7 cases per year and within 48 hours in 3.5 cases. Although coincident vaccination and SIDS should not be a frequent problem, it can be expected to occur at least annually in Australia by chance alone. The probabilities of vaccination by age estimated in this study can also be applied to estimate the probability of a vaccination encounter for children who have experienced any unusual medical condition or death, when these occurrences are known to be unrelated to vaccination.

  16. Development of an ultrahigh-resolution Si-PM-based dual-head GAGG coincidence imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp [Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Watabe, Hiroshi; Kanai, Yasukazu [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Kato, Katsuhiko [Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Hatazawa, Jun [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, Osaka (Japan)

    2013-03-01

    A silicon photomultiplier (Si-PM) is a promising photodetector for high resolution PET systems due to its small channel size and high gain. Using Si-PMs, it will be possible to develop a high resolution imaging systems. For this purpose, we developed a small field-of-view (FOV) ultrahigh-resolution Si-PM-based dual-head coincidence imaging system for small animals and plant research. A new scintillator, Ce doped Gd{sub 3}Al{sub 12}Ga{sub 3}O{sub 12} (GAGG), was selected because of its high light output and its emission wavelength matched with the Si-PM arrays and contained no radioactivity. Each coincidence imaging block detector consists of 0.5×0.5×5 mm{sup 3} GAGG pixels combined with a 0.1-mm thick reflector to form a 20×17 matrix that was optically coupled to a Si-PM array (Hamamatsu MPPC S11064-050P) with a 1.5-mm thick light guide. The GAGG block size was 12.0×10.2 mm{sup 2}. Two GAGG block detectors were positioned face to face and set on a flexible arm based detector stand. All 0.5 mm GAGG pixels in the block detectors were clearly resolved in the 2-dimensional position histogram. The energy resolution was 14.4% FWHM for the Cs-137 gamma ray. The spatial resolution was 0.7 mm FWHM measured using a 0.25 mm diameter Na-22 point source. Small animal and plant images were successfully obtained. We conclude that our developed ultrahigh-resolution Si-PM-based dual-head coincidence imaging system is promising for small animal and plant imaging research.

  17. Development of an ultrahigh-resolution Si-PM-based dual-head GAGG coincidence imaging system

    Science.gov (United States)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Kato, Katsuhiko; Hatazawa, Jun

    2013-03-01

    A silicon photomultiplier (Si-PM) is a promising photodetector for high resolution PET systems due to its small channel size and high gain. Using Si-PMs, it will be possible to develop a high resolution imaging systems. For this purpose, we developed a small field-of-view (FOV) ultrahigh-resolution Si-PM-based dual-head coincidence imaging system for small animals and plant research. A new scintillator, Ce doped Gd3Al12Ga3O12 (GAGG), was selected because of its high light output and its emission wavelength matched with the Si-PM arrays and contained no radioactivity. Each coincidence imaging block detector consists of 0.5×0.5×5 mm3 GAGG pixels combined with a 0.1-mm thick reflector to form a 20×17 matrix that was optically coupled to a Si-PM array (Hamamatsu MPPC S11064-050P) with a 1.5-mm thick light guide. The GAGG block size was 12.0×10.2 mm2. Two GAGG block detectors were positioned face to face and set on a flexible arm based detector stand. All 0.5 mm GAGG pixels in the block detectors were clearly resolved in the 2-dimensional position histogram. The energy resolution was 14.4% FWHM for the Cs-137 gamma ray. The spatial resolution was 0.7 mm FWHM measured using a 0.25 mm diameter Na-22 point source. Small animal and plant images were successfully obtained. We conclude that our developed ultrahigh-resolution Si-PM-based dual-head coincidence imaging system is promising for small animal and plant imaging research.

  18. Evaluation of equipment performance, patient dose, imaging quality, and diagnostic coincidence in five Mexico City mammography services.

    Science.gov (United States)

    Brandan, María-Ester; Ruiz-Trejo, César; Verdejo-Silva, Maricela; Guevara, Martha; Lozano-Zalce, Horacio; Madero-Preciado, Luis; Martín, Julia; Noel-Etienne, Louise-Marie; Ramírez-Arias, José-Luis; Soto, Jesús; Villaseñor, Yolanda

    2004-01-01

    Regulations concerning the use of x-rays in medical diagnoses were published in Mexico in 1997. In this work, we evaluate technical aspects of mammography services in the Mexico City area and radiation dose and coincidence between the radiological interpretation by the institution radiologist and by a panel of experts. Following methodology proposed by the American College of Radiology and the European Community among others, we have evaluated the performance of six mammography systems in Mexico City public and private services. The studied services carry out approximately one half of the mammography studies in the capital's metropolitan area. The systems comply with 53-82% of a total of 31 applied quality control tests and measurements, which include the mammography unit, x-ray generation, collimation, automatic exposure control, compression devices, grid and image receptor, film processing, darkroom, viewboxes, dose, film rejection, and image quality. The elements that most frequently fail are film processing, darkroom, and light boxes; average ACR phantom score is 11.2 (9.5, 12.0); mean average glandular dose measured with the phantom is 1.00 (0.71-1.15) mGy, and measured in patients is 1.75 (0.3, 4.9) mGy; coincidence between radiologic reports (BI-RADS) by the institution radiologist and a panel of experts is obtained in 35% of studied cases. Statistical analysis of results indicated that the level of equipment performance is correlated with image quality, image quality estimated by the panel of radiologists is correlated with phantom score, and coincidence in clinical mammography reports is not correlated with equipment performance and appears to depend on the radiologist's experience.

  19. Cardiovascular risk factors are really linked in the metabolic syndrome: this phenomenon suggests clustering rather than coincidence.

    Science.gov (United States)

    Aizawa, Yoshifusa; Kamimura, Norihito; Watanabe, Hiroshi; Aizawa, Yoshiyasu; Makiyama, Yashiro; Usuda, Yoshimaru; Watanabe, Tohru; Kurashina, Yoshiaki

    2006-05-10

    The accumulation of cardiovascular risk factors can be seen in a single person but it needs to be determined if this occurs more frequently than might be explained by mere coincidence. This study involved 119,412 adults: 41,819 males and 77,593 females, who were 40 years of age or older and who underwent an annual health examination. From the clinical and biochemical data, the actual prevalence of a combination of 3 or more factors: abnormal body mass index (> or =25.0), hypertension, high triglyceride (> or =150 mg/dl), low HDL cholesterol (metabolism (fasting blood sugar > or =110 mg/dl or HbA1c. > or =5.5%) was determined. Then, the prevalence of a corresponding combination of 3-5 factors was predicted from the prevalence of each factor on the assumption that their combination occurs as a result of coincidence. The criteria of metabolic syndrome (> or =3 risk factors) was met in 17,842 (14.9%) of the examinees. The actual prevalence of any combination of 3-5 factors of metabolic syndrome was more frequent than those expected to occur by coincidence (P metabolic syndrome compared to that in the total examinees but it was 1.7 to 2.1 times higher in hypertension and high triglyceride. The former two were clustering more than hypertension or high triglyceride in metabolic syndrome. Abnormal levels of serum creatinine and total cholesterol were found more often in metabolic syndrome. Combinations of risk factors of metabolic syndrome were found more frequently than coincidental phenomenon in the subjects from the general population. These finding suggest that these risk factors do cluster and obesity and insulin resistance were suggested to be linked with metabolic syndrome more than hypertension or high triglyceride.

  20. A new method of time difference measurement: The time difference method by dual phase coincidence points detection

    Science.gov (United States)

    Zhou, Wei

    1993-01-01

    In the high accurate measurement of periodic signals, the greatest common factor frequency and its characteristics have special functions. A method of time difference measurement - the time difference method by dual 'phase coincidence points' detection is described. This method utilizes the characteristics of the greatest common factor frequency to measure time or phase difference between periodic signals. It can suit a very wide frequency range. Measurement precision and potential accuracy of several picoseconds were demonstrated with this new method. The instrument based on this method is very simple, and the demand for the common oscillator is low. This method and instrument can be used widely.