WorldWideScience

Sample records for electron-beam treatment estudos

  1. Electron beam flue gas treatment process. Review

    Energy Technology Data Exchange (ETDEWEB)

    Honkonen, V.A. [Kuopio Univ. (Finland). Dept. of Physics; Chmielewski, A.G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    The basis of the process for electron beam flue gas treatment are presented in the report. In tabular form the history of the research is reviewed. Main dependences of SO{sub 2} and NO{sub x} removal efficiencies on different physico-chemical parameters are discussed. Trends concerning industrial process implementation are presented in the paper,finally. (author). 74 refs, 11 figs, 1 tab.

  2. Estimation of the Processing Parameters in Electron Beam Thermal Treatments

    OpenAIRE

    Dulau, Mircea

    2014-01-01

    Electron beam have many special properties which make them particularly well suited for use in materials handling through melting, welding, surface treatment, etc., taking into account that this manufacturing is performed in vacuum. The use of electron beam for surface limited heat treatment of workpiece has brought about a noticeable extension of the beam technologies. Some theoretical aspects and simulation results are presented in this paper, considering a high power electron beam processi...

  3. Estimation of the Processing Parameters in Electron Beam Thermal Treatments

    Directory of Open Access Journals (Sweden)

    DULAU Mircea

    2014-05-01

    Full Text Available Electron beam have many special properties which make them particularly well suited for use in materials handling through melting, welding, surface treatment, etc., taking into account that this manufacturing is performed in vacuum. The use of electron beam for surface limited heat treatment of workpiece has brought about a noticeable extension of the beam technologies. Some theoretical aspects and simulation results are presented in this paper, considering a high power electron beam processing system and Matlab facilities. This paper can be used in power engineering and electro-technologies fields as a guideline, in order to simulate and analyse the process parameters.

  4. Gap application results for adjacent electron beams treatment

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio, Francisco G.A., E-mail: francisampaio@pg.ffclrp.usp.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Del Lama, Lucas S., E-mail: lucasdellama@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Petchevist, Paulo C.D., E-mail: petchevist12@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Instituto de Radioterapia e Megavoltagem de Ribeirao Preto - IRMEV, Rua Sete de Setembro 1150, CEP 14010-180, Ribeirao Preto, SP (Brazil); Moreira, Marcos V., E-mail: marcos_vasques@yahoo.com.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil); Instituto de Radioterapia e Megavoltagem de Ribeirao Preto - IRMEV, Rua Sete de Setembro 1150, CEP 14010-180, Ribeirao Preto, SP (Brazil); Almeida, Adelaide de, E-mail: dalmeida@ffclrp.usp.br [Departamento de Fisica - FFCLRP, Universidade de Sao Paulo - USP, Av. dos Bandeirantes 3900, CEP 14040-901, Ribeirao Preto, SP (Brazil)

    2011-12-15

    Nowadays, electron beams from high-energy linear accelerators (LINAC) are widely used in a variety of radiotherapy treatments being suitable especially for superficial tumors. Since this sort of ionizing radiation has stopping power higher than photons, deeper and healthier tissues can be preserved. On the other hand, when applying adjacent electron beams, 'hot' spots can be observed, due to penumbra and/or scattering, contributing to the increase of the absorbed dose in the target volume. In this sense, the objective of this work was to investigate the effects of parallel adjacent electron beams using the chemical dosimeter Fricke Xylenol Gel (FXG) and compare the experimental results with ones acquired using Monte Carlo simulation. Thus, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15 and 20 Multiplication-Sign 20 cm{sup 2} fields were irradiated with 5, 8 and 10 MeV electron beams applying different gap widths. The experimental results and the simulations indicated overdose values up to 40% from the prescribed one for the specific tumor. This demonstrates that specific gaps are necessary in the case of treatments with parallel adjacent electron beams in order to prevent overdoses in the depth of interest.

  5. Mathematical model of mass transfer at electron beam treatment

    Science.gov (United States)

    Konovalov, Sergey V.; Sarychev, Vladimir D.; Nevskii, Sergey A.; Kobzareva, Tatyana Yu.; Gromov, Victor E.; Semin, Alexander P.

    2017-01-01

    The paper proposes a model of convective mass transfer at electron beam treatment with beams in titanium alloys subjected to electro-explosion alloying by titanium diboride powder. The proposed model is based on the concept that treatment with concentrated flows of energy results in the initiation of vortices in the melted layer. The formation mechanism of these vortices rooted in the idea that the availability of temperature drop leads to the initiation of the thermo-capillary convection. For the melted layer of metal the equations of the convective heat transfer and boundary conditions in terms of the evaporated material are written. The finite element solution of these equations showed that electron-beam treatment results in the formation of multi-vortex structure that in developing captures all new areas of material. It leads to the fact that the strengthening particles are observed at the depth increasing many times the depth of their penetration according to the diffusion mechanism. The distribution of micro-hardness at depth and the thickness of strengthening zone determined from these data supported the view that proposed model of the convective mass transfer describes adequately the processes going on in the treatment with low-energy high-current electron beam.

  6. New "wet type" electron beam flue gas treatment pilot plant

    Science.gov (United States)

    Tan, Erdal; Ünal, Suat; Doğan, Alişan; Letournel, Eric; Pellizzari, Fabien

    2016-02-01

    We describe a new pilot plant for flue gas cleaning by a high energy electron beam. The special feature of this pilot plant is a uniquely designed reactor called VGS® (VIVIRAD Gas Scrubber, patent pending), that allows oxidation/reduction treating flue gas in a single step. The VGS® process combines a scrubber and an advanced oxidation/reduction process with the objective of optimizing efficiency and treatment costs of flue gas purification by electron accelerators. Promising treatment efficiency was achieved for SOx and NOx removal in early tests (99.2% and 80.9% respectively). The effects of various operational parameters on treatment performance and by-product content were investigated during this study.

  7. Electron beam treatment of tungsten mock-ups

    Science.gov (United States)

    Zalavutdinov, R.; Novokhatsky, A.; Gusev, V.; Bukhovets, V.; Gorodetsky, A.; Kuznetsov, V.; Litunovsky, N.; Makhankov, A.; Mazul, I.; Mukhin, E.; Petrov, Yu; Rybkina, T.; Sakharov, N.; Tolstyakov, S.; Voronin, A.; Zakharov, A.

    2017-12-01

    To simulate thermal loads in ITER several tungsten (W) water cooled mock-ups were treated by a scanning electron beam (Tsefey-M) at a heat flux up to 1.68 GW m‑2 for a duration of 18 μs and a frequency about 30 kHz. Surface morphology, chemical composition, structure, and microhardness of formed W layers were analyzed by SEM, EPMA, XRD, OM, and Vickers hardness tester. The irradiation treatment resulted in W melting to a depth of 0.3 mm, increasing sub-surface grain sizes, grain ordering in the metal bulk, deep cracking, and decreasing of microhardness to a depth of 2–4 mm. Installation of the pre-damaged W samples in a tokamak Globus-M divertor did not change practically discharge conditions.

  8. An investigation on some of the tumor treatment cases using x-rays and electron beams

    Science.gov (United States)

    Ucar, Burcu; Yigitoglu, Ibrahim; Arslan Kabalay, Ipek; Altiparmak, Duygu; Kilicaslan, Sinem

    2015-07-01

    In this work, we discussed some of the applications which X-rays and electron beam used in radiotherapy for tumor treatments. This study has been performed at Radiation Oncology Department, Medicine Faculty in Gaziosmanpasa University by using the VARIAN CLINICA DHX linear accelerator which is operated in the range of 6 MeV - 15 MeV. Processes for the treatments that X-rays used for pancreas, bladder and prostate tumors and the processes that the electron beam used for some of the derm tumors are studied. Effects of X-rays and electron beams to treatments process are examined and the obtained results are presented comparatively.

  9. Surface treatment by the ion flow from electron beam generated plasma in the forevacuum pressure range

    Directory of Open Access Journals (Sweden)

    Klimov Aleksandr

    2018-01-01

    Full Text Available The paper presents research results of peculiarities of gas ion flows usage and their generation from large plasma formation (>50 sq.cm obtained by electron beam ionization of gas in the forevacuum pressure range. An upgraded source was used for electron beam generation, which allowed obtaining ribbon electron beam with no transmitting magnetic field. Absence of magnetic field in the area of ion flow formation enables to obtain directed ion flows without distorting their trajectories. In this case, independent control of current and ion energy is possible. The influence of electron beam parameters on the parameters of beam plasma and ion flow – current energy and density – was determined. The results of alumina ceramics treatment with a beam plasma ions flow are given.

  10. Clinical use of a commercial Monte Carlo treatment planning system for electron beams.

    Science.gov (United States)

    Cygler, J E; Lochrin, C; Daskalov, G M; Howard, M; Zohr, R; Esche, B; Eapen, L; Grimard, L; Caudrelier, J M

    2005-03-07

    In 2002 we fully implemented clinically a commercial Monte Carlo based treatment planning system for electron beams. The software, developed by MDS Nordion (presently Nucletron), is based on Kawrakow's VMC++ algorithm. The Monte Carlo module is integrated with our Theraplan Plustrade mark treatment planning system. An extensive commissioning process preceded clinical implementation of this software. Using a single virtual 'machine' for each electron beam energy, we can now calculate very accurately the dose distributions and the number of MU for any arbitrary field shape and SSD. This new treatment planning capability has significantly impacted our clinical practice. Since we are more confident of the actual dose delivered to a patient, we now calculate accurate three-dimensional (3D) dose distributions for a greater variety of techniques and anatomical sites than we have in the past. We use the Monte Carlo module to calculate dose for head and neck, breast, chest wall and abdominal treatments with electron beams applied either solo or in conjunction with photons. In some cases patient treatment decisions have been changed, as compared to how such patients would have been treated in the past. In this paper, we present the planning procedure and some clinical examples.

  11. Electron beam flue gas treatment. Research cooperation among JAERI, IAEA and INCT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    The research co-operation is conducted among Japan Atomic Energy Research Institute (JAERI), International Atomic Energy Agency (IAEA) and Institute of Nuclear Chemistry and Technology in Poland (INCT) on Electron Beam Flue Gas Treatment from January 1993 to March 1997. The first phase of the cooperation was carried out for 3 years from January 1993 to March 1995. This cooperation was performed through information exchange meetings (Coordination Meetings), held in Takasaki and Warsaw, and experiments and discussions by exchange scientists. Many useful results were obtained on electron beam treatment of flue gas from coal-combustion heat generation plant in Kaweczyn within the frame work of the research co-operation. This report includes the main results of the tripartite research cooperation. (author)

  12. Effects of ion- and electron-beam treatment on surface physicochemical properties of polylactic acid

    Science.gov (United States)

    Pukhova, I. V.; Savkin, K. P.; Laput, O. A.; Lytkina, D. N.; Botvin, V. V.; Medovnik, A. V.; Kurzina, I. A.

    2017-11-01

    We describe our investigations of the surface physicochemical and mechanical properties of polylactic acid modified by silver, argon and carbon ion implantation to doses of 1 × 1014, 1 × 1015 and 1 × 1016 ions/cm2 at energies of 20 keV (for C and Ar) and 40 keV (for Ag), and by electron beam treatment with pulse-width of 100-300 μs in 50 μs increments at a beam energy 8 keV. Carbonyl bonds (sbnd Cdbnd O) related IR peak was reduced after ion and electron beam irradiation. Molecular weight of PLA decreases twice and does not depend on the nature of the bombarding particles. The microhardness of treated samples decreases by a factor of 1.3, and the surface conductivity increases by 6 orders of magnitude after ion implantation, and increases only modestly after electron beam treatment. Atomic force microscopy shows that surface roughness increases with irradiation dose. Samples irradiated with Ag to a dose of 1 × 1016 ions/cm2 show the greatest roughness of 190 nm.

  13. Introduction to Radiotherapy with Photon and Electron Beams and Treatment Planning from Conformal Radiotherapy to IMRT

    Science.gov (United States)

    Wilkens, Jan J.

    2007-11-01

    Besides surgery and chemotherapy, radiation therapy is one of the three main treatment options for cancer patients. This paper provides an introduction to the basic principles of radiotherapy with photons and electrons. It includes a brief summary of the physical properties for photon and electron beams as well as a description of treatment machines used to create these beams. The second part introduces the treatment planning process as it is commonly employed in radiotherapy. It covers dose calculation algorithms, conventional planning strategies for three-dimensional conformal radiotherapy, and optimization techniques for intensity modulated radiotherapy (IMRT).

  14. Stabilization of a cold cathode electron beam glow discharge for surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Mingolo, N.; Gonzalez, C.R. [Lab. de Haces Dirigidos, Depto. de Fisica, Facultad de Ingenieria, Universidad de Buenos Aires, Paseo Colon 850, 1063 Buenos Aires (Argentina); Martinez, O.E. [Lab. de Electronica Cuantica, Depto. de Fisica, Universidad de Buenos Aires, Pabellon 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); Rocca, J.J. [Department of Electrical Engineering, Colorado State University, Fort Collins, Colorado 80523 (United States)

    1997-10-01

    We have demonstrated that the reproducibility of electron beam pulses generated by a high power, cold cathode glow discharge is greatly improved by adding a small continuous keep-alive discharge current. A current of the order of 200 {mu}A was found to limit the shot to shot current variation to within 1.5{percent}. This stabilization in turn reduces by an order of magnitude the fluctuations of the energy density deposited on the target, demonstrating a reliable energy source for surface treatment. {copyright} {ital 1997 American Institute of Physics.}

  15. [Depth dose characteristics of electron beams released from a scanning type Racetrack Microtron treatment machine].

    Science.gov (United States)

    Sato, Tomoharu

    2002-01-01

    The Racetrack Microtron MM50 capable of taking out x-rays and electron beams having a high energy of up to 50 MeV was evaluated by a dosimetry of electron beams in comparison with Microtron MM22. The MM50 flattens the intensity of electron beams by using the beam scanning method while the MM22 utilizes the flattening-filter method. A percentage depth dose (PDD) curve was obtained through the dosimetry of electron beams using a water phantom. As compared with the MM22, the MM50 emits an electron beam that has an energy much closer to the nominal one, that is less contaminated by x-rays, and whose intensity decreases steeply down to near zero on the PDD curve. The MM50 has an electron beam dose distribution that is practically useful since the dose tends to be concentrated on the target volume.

  16. Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam; Estudo de viabilidade tecnica e economica para implementacao de uma unidade movel para tratamento de efluentes industriais com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Rela, Carolina Sciamarelli

    2006-07-01

    The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit. (author)

  17. Treatment result of so-called keloid with electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Masatsugu; Narabayashi, Isamu; Tatsumi, Toshiaki; Sueyoshi, Kozo; Uesugi, Yasuo; Nakata, Yasunobu; Tajima, Sadao [Osaka Medical Coll., Takatsuki (Japan)

    1999-03-01

    Between September 1993 and February 1997, 28 sites of so-called keloid (14 true keloids and 14 hypertrophic scars) were treated with electron beam irradiation. Twenty-five of these sites were treated with surgical excision followed by radiotherapy, and the other 3 sites received radiotherapy only. Irradiation by 9 MeV electron beam was performed for all patients, with a total dose of 20 Gy (10 fractions for 2 weeks). The results were evaluated at 8-49 months (Ave. 28.4 months) after treatment. Three sites treated with radiation more than 60 days after excision were excluded from evaluation of treatment response. Twenty-two of 25 sites showed complete response (CR) or partial response (PR). The control rate of total sites was 88.0%. The control rate was 92.9% in true keloids and 81.8% in hypertrophic scars. All keloid sites in the face, neck, shoulder, back and arm exhibited CR. One site of keloid in the head showed no response (NR). In 10 sites in the thoracic lesion, 8 were PR (80.0%) and 2 were NR (20.0%). In 8 sites in the abdominal lesion, 6 were CR (75.0%), 2 were PR (25.0%). All 3 non-operative sites exhibited PR. The control rate of sites treated with radiation within 14 days after keloid excision was 80.0% and that in sites treated more than 15 days after excision was 100.0%. Seven sites (7/28=25.0%) developed acute reaction, which were demonstrated erythema in the irradiated field, but this reaction was transient. Five sites (5/28=17.9%) showed hyperpigmentation indicating late reaction. The development of malignant tumor in or around the irradiated field was not shown. Postoperative electron beam irradiation was effective for so-called keloid. These data suggest that 10-fraction irradiation controls low grade of hyperpigmentation development, even though patients received a comparatively high total dose of radiotherapy. (author)

  18. Electron Beam-Induced Immobilization of Laccase on Porous Supports for Waste Water Treatment Applications

    Directory of Open Access Journals (Sweden)

    Elham Jahangiri

    2014-08-01

    Full Text Available The versatile oxidase enzyme laccase was immobilized on porous supports such as polymer membranes and cryogels with a view of using such biocatalysts in bioreactors aiming at the degradation of environmental pollutants in wastewater. Besides a large surface area for supporting the biocatalyst, the aforementioned porous systems also offer the possibility for simultaneous filtration applications in wastewater treatment. Herein a “green” water-based, initiator-free, and straightforward route to highly reactive membrane and cryogel-based bioreactors is presented, where laccase was immobilized onto the porous polymer supports using a water-based electron beam-initiated grafting reaction. In a second approach, the laccase redox mediators 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid (ABTS and syringaldehyde were cross-linked instead of the enzyme via electron irradiation in a frozen aqueous poly(acrylate mixture in a one pot set-up, yielding a mechanical stable macroporous cryogel with interconnected pores ranging from 10 to 50 µm in size. The membranes as well as the cryogels were characterized regarding their morphology, chemical composition, and catalytic activity. The reactivity towards waste- water pollutants was demonstrated by the degradation of the model compound bisphenol A (BPA. Both membrane- and cryogel-immobilized laccase remained highly active after electron beam irradiation. Apparent specific BPA removal rates were higher for cryogel- than for membrane-immobilized and free laccase, whereas membrane-immobilized laccase was more stable with respect to maintenance of enzymatic activity and prevention of enzyme leakage from the carrier than cryogel-immobilized laccase. Cryogel-immobilized redox mediators remained functional in accelerating the laccase-catalyzed BPA degradation, and especially ABTS was found to act more efficiently in immobilized than in freely dissolved state.

  19. Surface Nanostructure Formations in an AISI 316L Stainless Steel Induced by Pulsed Electron Beam Treatment

    Directory of Open Access Journals (Sweden)

    Yang Cai

    2015-01-01

    Full Text Available High current pulsed electron beam (HCPEB is an efficient technique for surface modifications of metallic materials. In the present work, the formations of surface nanostructures in an AISI 316L stainless steel induced by direct HCPEB treatment and HCPEB alloying have been investigated. After HCPEB Ti alloying, the sample surface contained a mixture of the ferrite and austenite phases with an average grain size of about 90 nm, because the addition of Ti favors the formation of ferrite. In contrast, electron backscattered diffraction (EBSD analyses revealed no structural refinement on the direct HCPEB treated sample. However, transmission electron microscope (TEM observations showed that fine cells having an average size of 150 nm without misorientations, as well as nanosized carbide particles, were formed in the surface layer after the direct HCPEB treatment. The formation of nanostructures in the 316L stainless steel is therefore attributed to the rapid solidification and the generation of different phases other than the steel substrate in the melted layer.

  20. Unilateral parotid electron beam radiotherapy as palliative treatment for sialorrhea in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Kasarskis, Edward J; Hodskins, Jacob; St Clair, William H

    2011-09-15

    When ALS patients experience oropharyngeal weakness, sialorrhea can become a considerable challenge. Drooling has a profound negative impact in patient's quality of life causing embarrassing social situations. Several therapeutic modalities, including anticholinergic drugs, botulinum toxin injection, and radiotherapy have emerged as treatments for drooling in ALS. This retrospective case series study examined the effect of palliative radiotherapy in controlling problematic oral secretions in 10 ALS patients refractory to medical management. External electron beam radiation was targeted to a single parotid gland unilaterally with a total dose of 1500 cGy in 3 fractions at a depth determined by CT scanning. One patient received additional radiotherapy to the contralateral parotid due to persistent secretions. All patients reported improvement with a reduction in the intensity and amount of drooling. In 5 of 10 patients, anticholinergics were discontinued and were reduced in another two. There were no major side effects of treatment. We conclude that unilateral parotid electron radiotherapy provides satisfactory relief from sialorrhea in ALS patients and should be considered as a therapeutic option for patients who are refractory to medical management. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Effect of postweld treatment on the fatigue crack growth rate of electron-beam-welded AISI 4130 steel

    Science.gov (United States)

    Wang, Chien-Chun; Chang, Yih

    1996-10-01

    This article studies the effect of in-chamber electron beam and ex-chamber furnace postweld treatments on the fatigue crack growth rate of electron-beam-welded AISI 4130 steel. Mechanical properties of the weldment are evaluated by tensile testing, while the fatigue properties are investigated by a fatigue crack propagation method. Microstructural examination shows that both postweld treatments temper the weldment by the appropriate control of beam pattern width, input beam energy, and furnace temperature. In addition, the ductility, strength, and microhardness of the weldment also reflect this tempering effect. The fatigue crack growth rate is decreased after both postweld treatments. This is mainly caused by the existence of a toughened microstructure and relief of the residual stress due to the fact that (1) the residual stress becomes more compressive as more beam energy is delivered into the samples and (2) postweld furnace tempering effectively releases the tensile stress into a compressive stress state.

  2. Heat treatment induced phase transition and microstructural evolution in electron beam surface melted Nb-Si based alloys

    Science.gov (United States)

    Guo, Yueling; Jia, Lina; Kong, Bin; Peng, Hui; Zhang, Hu

    2017-11-01

    The hardness, phase and microstructural development of Nb-18Si-24Ti-2Cr-2Al (at.%) alloys processed by electron beam surface melting (EBSM) and subsequent heat treatments were investigated. The EBSM experiments were performed using an electron beam based 3D printing system. Results showed that Nbss and Nb3Si phases were obtained via EBSM with a significantly refined microstructure. The eutectoid reaction of Nb3Si → Nbss + αNb5Si3 was triggered by heat treatments (HT) at 1200 °C or 1450 °C for 5 h. The growth and the coarsening of αNb5Si3 grains were promoted with a higher HT temperature. The hardness of the EBSM alloy was remarkably reduced by HT.

  3. [Treatment of nasal malignant tumor with electron beam irradiation after repair of nasolabial flap].

    Science.gov (United States)

    Zhang, Jianjun; Chen, Faguo; Yi, Chuanxun; Ye, Ruoshui; Ci, Hai; Hui, Huanli; Hai, Lati

    2009-09-01

    To explore the appropriate reconstructive methods and curative effect after nasal skin malignant tumor excision. Nasolabial flap was selected to cover the nasal defects in 15 cases which nasal tumors were removed. The secondary defect of donor site was directly sutured. Electron beam conventional radiotherapy (DT40-50 Gy/20-25 times/4-5 weeks) was delivered to the involved field after incision sutured out 2-5 days. A total of 15 patients with nasal tumor were available for follow-up of 6 to 24 months, no tumor recurrence occurred, and the repaired tissue were good match with surrounding tissue, good nasal contour was obtained with an inconspicuous scar. These data indicate that the nasolabial flap can be used to repair defects of the nose tumors in 15 cases and is surgically convenient. Combination of nasolabial flap repairing and postoperative local electron beam irradiation, inhibited the recurrence of nose tumor effectively, is an ideal method.

  4. Dosimetric comparison of electron beam and 9{sup 0}Sr+{sup 90}Y applicator for keloids treatment

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Talita S.; Tada, Ariane; Antonio, Patricia L.; Yoriyaz, Helio, E-mail: tasallesc@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Fernandes, Marco A.R., E-mail: marco@cetea.com.b [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Dept. de Dermatologia e Radioterapia Rubiao Junior

    2009-07-01

    Studies have been shown that among several methods that have been used for the treatment of keloids the surgical excision followed by the adjuvant radiotherapy presents the lowest relapsed rate of the injury. In this work a comparative dosimetric study has been performed using a 4 MeV electron beam from a Varian Clinac 2100C linear accelerator at the radiotherapy service of the Hospital das Clinicas of UNESP-HC, Botucatu-SP and an Amershan {sup 90}Sr+{sup 90}Y brachytherapy applicator with 1491 MBq of activity. Percentage depth dose curves from ionization chamber measurements and through Monte Carlo simulation have been obtained and compared. Dose measurements have been obtained using parallel plates ionization chamber (Esradin A12) and extrapolation mini-chamber developed at IPEN. The dose calculations have been obtained using the well-known Monte Carlo radiation transport code MCNP-4C. Maximum dose differences obtained between measured/calculated values for {sup 90}Sr+{sup 90}Y applicator and for the electron beam were, respectively: 7.8 % and 8.0%. The profiles of the depth and superficial tissue dose distribution produced by the electron beam revealed themselves flatter and more homogeneous than those produced by the {sup 90}Sr+{sup 90}Y applicator, especially to wider fields, which cannot be obtained with beta therapy applicators because of their geometric limitations. In conclusion this present work has shown that {sup 90}Sr+{sup 90}Y applicators could be efficient for small and very superficial lesions but in most cases electron beam sources are more adequate especially for large and deeper lesions. (author)

  5. Treatment of toluene and its by-products using an electron beam/ultra-fine bubble hybrid system

    Science.gov (United States)

    Son, Youn-Suk; Kim, Tae-Hun; Choi, Chang Yong; Park, Jun-Hyeong; Ahn, Ji-Won; Dinh, Trieu-Vuong

    2018-03-01

    Although, until quite recently, many technologies (electron beam (EB), plasma, and ultraviolet) have been studied to overcome disadvantages of conventional methods (such as absorption, adsorption, biofiltration and incineration) for treatment of volatile organic compounds (VOCs), their techniques still have some problems such as formation of a by-product. Generally, it is reported that various by-products are generated from the EB irradiation process to remove VOCs. Therefore, we developed an electron beam/ultra-fine bubble (EB/UB) hybrid system to enhance removal efficiency of a VOC (toluene) and to reduce its by-products formed by electron beam irradiation. As a result, the removal efficiency of toluene (30 ppm) by only EB (10 kGy) was 80.1%. However, the removal efficiency of toluene using the hybrid system (water temperature: 5 ℃) was increased up to 17% when compared to only EB (10 kGy). Additionally, the 65.2% of ozone formed from the EB process was removed in UB reactor. In case of other trace by-products such as undesired VOCs and aldehydes, the levels were lowered down to the below detection limit by the subsequent UB reactor. We also found that the amount of toluene collected and solubilized into water is affected by the water temperature in the UB reactor.

  6. Nanostructure Formations and Improvement in Corrosion Resistance of Steels by Means of Pulsed Electron Beam Surface Treatment

    Directory of Open Access Journals (Sweden)

    K. M. Zhang

    2013-01-01

    Full Text Available The corrosion of steels has long been the topic for materials scientists. It is established that surface treatment is an efficient way to improve the corrosion resistance of steels without changing the bulk properties and with low costs. In the present paper, different kinds of surface treatment techniques for steels are briefly reviewed. In particular, the surface modification involving nanostructure formations of steels by using a low energy high pulsed electron beam (LEHCPEB treatment is lightened in the case of an AISI 316L stainless steel and D2 steel. The overall results demonstrate the high potential of the LEHCPEB technique for improving the corrosion performance of steels.

  7. THE INFLUENCE OF POSTHEAT TREATMENT ON FERRITE REDISTRIBUTION IN DUPLEX STEELS ELECTRON BEAM WELDS

    Directory of Open Access Journals (Sweden)

    Zita Iždinská

    2009-04-01

    Full Text Available The duplex stainless steel is two-phase steel with the structure composed of austenite and ferrite with optimum austenite/ferrite proportion 50%. At present, classical arc processes for welding duplex steels are generally regarded as acceptable. On the other hand electron and laser beam welding is up to now considered less suitable for welding duplex steels. The submitted work presents the results of testing various thermal conditions at welding duplex stainless steel with electron beam. It was shown, that application of suitable postheat made possible to reduce the ferrite content in weld metal.

  8. Effects of heat treatment and welding process on superelastic behaviour and microstructure of micro electron beam welded NiTi

    Directory of Open Access Journals (Sweden)

    Balz Isabel

    2016-09-01

    Full Text Available Medical devices with small dimensions made of superelastic NiTi become more popular, but joining these parts remains challenging. Since laser welding was found to be an option, electron beam welding seems to be an interesting alternative as it provides additional advantages due to the precise beam positioning and the high vacuum. Superelasticity is influenced by microstructure and surface layer composition that are mainly affected by welding process and by heat treatment and therefore will be investigated in the present paper.

  9. Numerical treatment of retarded radiation effects from high brightness electron beams

    Directory of Open Access Journals (Sweden)

    A. R. Rossi

    2009-10-01

    Full Text Available A form is given of the retarded electric field and magnetic induction generated by the motion of a charged particle that expresses these fields as integrals of the retarded charge density only, with kernels depending on the charge velocity and acceleration fields. In the case of a single pointlike charge, the usual Liénard-Wiechert fields follow very easily. The set of equations for the dynamics of particles in assigned electromagnetic fields with the self-consistent field is written and integrated. The code Retar for the dynamics of charged particles in external and self-consistent fields is described and a few examples of benchmark are proposed. As a physical application, the case of an electron beam moving in a bending magnetic dipole is examined, and the radiation produced analyzed, in order to characterize a therahertz radiation source.

  10. Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer.

    Science.gov (United States)

    Steel, Jared; Stewart, Allan; Satory, Philip

    2009-09-01

    Matching the penumbra of a 6 MeV electron beam to the penumbra of a 6 MV photon beam is a dose optimization challenge, especially when the electron beam is applied from an extended source-to-surface distance (SSD), as in the case of some head and neck treatments. Traditionally low melting point alloy blocks have been used to define the photon beam shielding over the spinal cord region. However, these are inherently time consuming to construct and employ in the clinical situation. Multileaf collimators (MLCs) provide a fast and reproducible shielding option but generate geometrically nonconformal approximations to the desired beam edge definition. The effects of substituting Cerrobend for the MLC shielding mode in the context of beam matching with extended-SSD electron beams are the subject of this investigation. Relative dose beam data from a Varian EX 2100 linear accelerator were acquired in a water tank under the 6 MeV electron beam at both standard and extended-SSD and under the 6 MV photon beam defined by Cerrobend and a number of MLC stepping regimes. The effect of increasing the electron beam SSD on the beam penumbra was assessed. MLC stepping was also assessed in terms of the effects on both the mean photon beam penumbra and the intraleaf dose-profile nonuniformity relative to the MLC midleaf. Computational techniques were used to combine the beam data so as to simulate composite relative dosimetry in the water tank, allowing fine control of beam abutment gap variation. Idealized volumetric dosimetry was generated based on the percentage depth-dose data for the beam modes and the abutment geometries involved. Comparison was made between each composite dosimetry dataset and the relevant ideal dosimetry dataset by way of subtraction. Weighted dose-difference volume histograms (DDVHs) were produced, and these, in turn, summed to provide an overall dosimetry score for each abutment and shielding type/angle combination. Increasing the electron beam SSD increased

  11. Total skin electron beam therapy as palliative treatment for cutaneous manifestations of advanced, therapy-refractory cutaneous lymphoma and leukemia

    Directory of Open Access Journals (Sweden)

    Hauswald Henrik

    2012-07-01

    Full Text Available Abstract Background To retrospectively access the outcome and toxicity of a total skin electron beam therapy (TSEBT in patients with cutaneous lymphoma (CL or leukemia. Patients and methods Treatment results of 25 patients (median age 63 years; 5 female, 20 male with cutaneous manifestations of advanced and therapy-refractory CL (n = 21; T-cell lymphomas n = 18, B-cell lymphomas n = 3 stage IIB-IV or leukemia (n = 4; AML n = 2, CLL n = 1, PDC n = 1 treated between 1993 and 2010 were reviewed. All patients were symptomatic. The median total dose was 29Gy, applied in 29 fractions of median 1 Gy each. Results The median follow-up was 10 months. Palliation was achieved in 23 patients (92%. A clinical complete response was documented in 13 (52% and a partial response in 10 patients (40%. The median time to skin progression was 5 months (range 1–18 months and the actuarial one-year progression-free survival 35%. The median overall survival (OS after the initiation of TSEBT was 10 months (range 1–46 months and the actuarial one-year OS 45%. TSEBT related acute adverse events (grade 1 or 2 were observed in all patients during the treatment period. An acute grade 3 epitheliolysis developed in eight patients (32%. Long-term adverse events as a hyperpigmentation of the skin (grade 1 or 2 were documented in 19 patients (76%, and a hypohidrosis in seven patients (28%. Conclusion For palliation of symptomatic cutaneous manifestations of advanced cutaneous lymphoma or leukemia, total skin electron beam therapy is an efficient and well tolerated considerable treatment option.

  12. Total skin electron beam therapy as palliative treatment for cutaneous manifestations of advanced, therapy-refractory cutaneous lymphoma and leukemia.

    Science.gov (United States)

    Hauswald, Henrik; Zwicker, Felix; Rochet, Nathalie; Uhl, Matthias; Hensley, Frank; Debus, Jürgen; Herfarth, Klaus; Bischof, Marc

    2012-07-29

    To retrospectively access the outcome and toxicity of a total skin electron beam therapy (TSEBT) in patients with cutaneous lymphoma (CL) or leukemia. Treatment results of 25 patients (median age 63 years; 5 female, 20 male) with cutaneous manifestations of advanced and therapy-refractory CL (n = 21; T-cell lymphomas n = 18, B-cell lymphomas n = 3) stage IIB-IV or leukemia (n = 4; AML n = 2, CLL n = 1, PDC n = 1) treated between 1993 and 2010 were reviewed. All patients were symptomatic. The median total dose was 29Gy, applied in 29 fractions of median 1 Gy each. The median follow-up was 10 months. Palliation was achieved in 23 patients (92%). A clinical complete response was documented in 13 (52%) and a partial response in 10 patients (40%). The median time to skin progression was 5 months (range 1-18 months) and the actuarial one-year progression-free survival 35%. The median overall survival (OS) after the initiation of TSEBT was 10 months (range 1-46 months) and the actuarial one-year OS 45%. TSEBT related acute adverse events (grade 1 or 2) were observed in all patients during the treatment period. An acute grade 3 epitheliolysis developed in eight patients (32%). Long-term adverse events as a hyperpigmentation of the skin (grade 1 or 2) were documented in 19 patients (76%), and a hypohidrosis in seven patients (28%). For palliation of symptomatic cutaneous manifestations of advanced cutaneous lymphoma or leukemia, total skin electron beam therapy is an efficient and well tolerated considerable treatment option.

  13. Improving corrosion and wear resistance of FV520B steel by high current pulsed electron beam surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Shengzhi, E-mail: ebeam@dlut.edu.cn [Key Laboratory of Material Modification by Laser, Ion and Electron Beams, Ministry of Education, Dalian University of Technology, Dalian 116024 (China); Zhao, Limin [School of Materials Science and Engineering, Dalian Jiaotong University, Dalian 116028 (China); Zhang, Yanlong; Wang, Huihui [Key Laboratory of Material Modification by Laser, Ion and Electron Beams, Ministry of Education, Dalian University of Technology, Dalian 116024 (China)

    2015-08-01

    Highlights: • HCPEB surface treatment was conducted on FV520B steel. • Surface layer ∼10 μm was refined with elements homogenization. • Remelted layer exhibited 〈2 0 0〉 preferential orientation. • Corrosion potential increased and corrosion rate decreased one order of magnitude. • Wear resistance increased by 3 times. - Abstract: High current pulsed electron beam (HCPEB) surface treatment was conducted on FV520B steel with accelerating voltage 27 kV, pulse duration 2.5 μs, energy density 5 J/cm{sup 2} and 1–25 pulses. The surface microstructure and element distribution were examined by using scanning electron microscope (SEM), electron probe micro-analysis (EPMA) and X-ray diffraction (XRD) methods. After HCPEB treatments, the surface microstructure became refined and uniform with an average grain size less than 2 μm and a preferential solidification orientation in 〈2 0 0〉 direction. The thickness of surface remelted layer was ∼4 μm. The initial precipitated particles in surface layer of depth ∼10 μm were dissolved into the base matrix and gave a homogenous element distribution. The HCPEB modified surface exhibited an effective improvement in corrosion and wear resistance. The corrosion potential shifted towards positive and the corrosion rate decreased nearly one order of magnitude, while the wear resistance after 25 pulses of HCPEB treatment increased by 3 times as compared with the initial FV520B steel.

  14. Gradient changes in structural condition of the B2 phase of NiTi surface layers after electron-beam treatments

    Energy Technology Data Exchange (ETDEWEB)

    Meisner, Ludmila L., E-mail: llm@ispms.tsc.ru, E-mail: egu@ispms.tsc.ru; Gudimova, Ekaterina Yu., E-mail: llm@ispms.tsc.ru, E-mail: egu@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055, Russia and National Research Tomsk State University, Tomsk, 634050 (Russian Federation); Ostapenko, Marina G., E-mail: artifact@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055, Russia and National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Lotkov, Aleksandr I., E-mail: lotkov@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation)

    2014-11-14

    Structural conditions of the B2 phase of the Ti{sub 49.5}Ni{sub 50.5} alloy surface layers before and after electron-beam treatments (pulse duration τ = 150 μs, number of pulses n = 5, beam energy density E ≤ 20 J/cm{sup 2}) were studied by X-ray diffraction analysis. Analysis of the X-ray patterns demonstrates that surface layers modified by electron beam treatment contain phase with B2{sup surf} structure. It is revealed that the lattice parameter of the B2{sup surf} phase in the surface (modified) layer is also higher than the lattice parameter of the B2 phase in the underlying layer (a{sub B2} = 3.0159±0.0005). The values of lattice parameter of phase B2{sup surf} amounted a{sub B2}{sup surf} = 3.0316±0.0005 Å and a{sub B2}{sup surf} = 3.0252±0.0005 Å, for the specimens after electron-beam treatment at E{sub 1} = 15 J/cm{sup 2} and E{sub 2} = 20 J/cm{sup 2}, respectively. Inflated lattice parameters a{sub B2}{sup surf} are associated with changes in the chemical composition and the presence of residual stresses in the surface region of the samples after electron-beam treatments.

  15. Electron beam-induced immobilization of laccase on porous supports for waste water treatment applications

    National Research Council Canada - National Science Library

    Jahangiri, Elham; Reichelt, Senta; Thomas, Isabell; Hausmann, Kristin; Schlosser, Dietmar; Schulze, Agnes

    2014-01-01

    ... of environmental pollutants in wastewater. Besides a large surface area for supporting the biocatalyst, the aforementioned porous systems also offer the possibility for simultaneous filtration applications in wastewater treatment...

  16. Surface modification of 40CrNiMo7 steel with high current pulsed electron beam treatment

    Science.gov (United States)

    Hao, Shengzhi; Wang, Huihui; Zhao, Limin

    2016-02-01

    High current pulsed electron beam (HCPEB) treatment was conducted on 40CrNiMo7 steel with accelerating voltage 27 kV, energy density 3 J/cm2, pulse duration 2.5 μs and 1-50 pulses. The evolutions of surface microstructure were investigated by using optical microscopy (OM), X-ray diffraction (XRD), scanning electron microscope (SEM) and transmission electron microscopy (TEM) techniques. It was found that the carbides in the surface remelted layer of depth ∼4 μm were dissolved gradually along with the increasing number of HCPEB pulses. Eventually, the surface microstructure of 40CrNiMo7 steel was transformed to a complex structure composed of very refined ∼150 nm austenite as the main part and a little quantity of martensite phases. After 15 pulses of HCPEB treatment, the surface microhardness was doubled to 553 HV, and the wear rate decreased to one third of the initial state correspondingly.

  17. Reduction of SO{sub x} and NO{sub x} emissions by electron beam flue gas treatment

    Energy Technology Data Exchange (ETDEWEB)

    Edinger, R. [PAVAC Industries Inc., Richmond, BC (Canada)

    2008-07-01

    Since the 1970s, laboratory studies and pilot demonstrations have been taking place at the Japan Atomic Energy Research Institute (JAERI) at the University of Tokyo to investigate the treatment of industrial flue gases by exposure to electron beams (EBFGT). Since that time, several installations have been built around the world with the most recent being at the Pomorzany power station in Poland. This paper discussed the use of EBFGT technology, with particular reference to its developmental history, equipment and technology, advantages, EBFGT concept, and carbon dioxide capture requirements. A List of EBFGT installations worldwide and their location were presented along with maximum flow rate, pollutant concentrations, and years of operations. An illustration of the sequence and time scales of the chemical reactions taking place was also included. In addition, the paper discussed the chemical reactions and economic sustainability of EBFGT. It was concluded that EBFGT technology is a building block towards an economically viable multi pollution control procedure. EBFGT can accommodate high removal rates for sulphur oxides and nitrogen oxides and therefore, satisfy carbon dioxide preparation requirements. 8 refs., 1 tab., 5 figs.

  18. Analysis of mixing conditions and multistage irradiation impact on NOx removal efficiency in the electron beam flue gas treatment process.

    Science.gov (United States)

    Pawelec, Andrzej; Dobrowolski, Andrzej

    2017-01-01

    In the process of electron beam flue gas treatment (EBFGT), most energy is spent on NOx removal. The dose distribution in the reactor is not uniform and the flue gas flow pattern plays an important role in the process efficiency. It was found that proper construction of the reactor may increase the energy efficiency of the process. The impact of the number of irradiation stages and mixing conditions on NOx removal efficiency was investigated for an ideal case and a practical solution was presented and compared with previously known EBFGT reactor constructions. The research was performed by means of computational fluid dynamics methods in combination with empirical Wittig formula. Two versions of dose distribution were taken for calculations. The results of the research show that for an ideal case, application of multistage irradiation and interstage mixing may reduce the energy consumption in the process by up to 39%. On the other side, simulation of reactor construction modification for two-stage irradiation results in 25% energy consumption reduction. The results of presented case study may be applied for improving the existing reactors and proper design of future installations.

  19. Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability

    Directory of Open Access Journals (Sweden)

    Suzan Bsat

    2015-04-01

    Full Text Available Advanced additive manufacturing techniques such as electron beam melting (EBM, can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M and immersion times (6, 24 h of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.

  20. THE EFFECT OF IRRADIATION DOSE AND AMMONIA CONCENTRATION ON THE APPLICATION OF ELECTRON BEAM FOR TREATMENT GASES POLLUTION OF SO2AND NOX

    Directory of Open Access Journals (Sweden)

    Erizal Erizal

    2010-06-01

    Full Text Available The application of electron beam for treatment gases pollution of SO2 and NOx has been studied.  The simulated SO2 and NOx gases stream produced from diesel fuel burning boiler were flown into electron beam chamber. Irradiation was conducted using 1000 keV electron beam machine at the dose up to 8.8 kGy, while   water vapour and the ammonia gas with variation concentration flew into the system during irradiation. The concentrations of the gases change were observed during processes. After evaluation, it was found that by increasing irradiation dose, the concentration of SO2 and NOx gases removal increases.  The efficiency of gases removal may reach 98 % for SO2 and 88 % for NOX at a dose of 8.8 kGy. By increasing ammonia concentration, the efficiency gas removal increases. Besides, by-products from the irradiation yield were sulfate and nitrate salt compound which are possible to be used as a fertilizer.      Keywords: radiation, electron beam, gas pollution, SO2, NOx, ammonia

  1. Total Skin Electron Beam Therapy in the Treatment of Mycosis Fungoides: A Review of Conventional and Low-Dose Regimens.

    Science.gov (United States)

    Chowdhary, Mudit; Chhabra, Arpit M; Kharod, Shivam; Marwaha, Gaurav

    2016-12-01

    Mycosis fungoides (MF) is the most prevalent subtype of cutaneous T-cell lymphoma, which is characterized by the proliferation of CD4(+) T cells. While often an indolent disease, most patients eventually develop progression from isolated patches to tumors and finally nodal or visceral involvement. Treatment choice is largely based on disease burden, though prognostic factors such as disease stage, patient age, and extracutaneous involvement must be taken into consideration. Radiotherapy represents one of the most effective therapeutic modalities in the treatment of MF. Lymphocytes are exquisitely radiosensitive, and excellent responses are observed even with low doses of radiation. Total skin electron beam therapy (TSEBT) is a special technique that allows for the homogenous irradiation of the entire skin. There are well-documented radiation dose-response relationships for achieving a complete response. As such, TSEBT doses ≥ 30 Gy comprise the current standard of care. Although highly effective, most patients experience recurrent disease even after conventional-dose (≥ 30 Gy) TSEBT. In addition, toxicity is cumulatively dose dependent, and there is reluctance to administer multiple courses of conventional-dose TSEBT. Consequently, there has been renewed interest in determining the utility of TSEBT at lower total (≤ 30 Gy) doses. Advantages of low-total-dose (with standard dose per fraction) TSEBT include a shortened treatment course, the potential to minimize the risk of adverse events, and the opportunity to allow for retreatment in cases of disease recurrence. This comprehensive review compares the impact of different TSEBT dosing schemes on clinical outcomes of MF. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Combination of electron beam irradiation and thermal treatment to enhance the shelf-life of traditional Indian fermented food (Idli)

    Science.gov (United States)

    Mulmule, Manoj D.; Shimmy, Shankar M.; Bambole, Vaishali; Jamdar, Sahayog N.; Rawat, K. P.; Sarma, K. S. S.

    2017-02-01

    Idli, a steam-cooked breakfast food item consumed in India, is famous as a staple food for its spongy texture and unique fermented taste. Idli preparation is a time consuming process; although instant Idli pre-mixes as powder or batter are available in the market, they do not have the distinctive taste and aroma similar to the Idli prepared at home. Hence ready-to-eat (RTE) form of this food is in demand. Therefore, an attempt was made to prepare RTE Idli bearing similar taste as home-cooked Idli with an extended shelf-life of up to two months at an ambient temperature using Electron Beam Irradiation (EBI) at dosages 2.5 kGy, 5 kGy and 7.5 kGy and combination processing comprised of EBI dosage at 2.5 kGy and thermal treatment (80 °C for 20 min). The treated Idli's were microbiologically and sensorially evaluated at storage periods of zero day, 14 days, 30 days and 60 days. Idli's irradiated at 7.5 kGy and subjected to combination processing at 2.5 kGy and thermal treatment were shelf-stable for 60 days. 2.5 kGy and 5 kGy radiation dosages alone were not sufficient to preserve Idli samples for more than 14 days. Undesirable change in sensory properties of Idli was observed at an EBI dosage of 7.5 kGy. Sensory properties of combination processed Idli's were found to undergo minor change over the storage period. The present work suggests that lowest radiation dosage in combination with thermal treatment could be useful to achieve the extended shelf-life without considerably impairing the organoleptic quality of Ready-to-Eat Idli.

  3. MO-H-19A-01: FEATURED PRESENTATION - Treatment Planning Tool for Radiotherapy with Very High-Energy Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova, M; Qu, B; Palma, B; Loo, B; Maxim, P [Stanford University, Stanford, CA (United States); Hynning, E; Hardemark, B [RaySearch Laboratories, Stockholm (Sweden)

    2014-06-15

    Purpose: To develop a tool for treatment planning optimization for fast radiotherapy delivered with very high-energy electron beams (VHEE) and to compare VHEE plans to state-of-the-art plans for challenging pelvis and H'N cases. Methods: Treatment planning for radiotherapy delivered with VHEE scanning pencil beams was performed by integrating EGSnrc Monte Carlo (MC) dose calculations with spot scanning optimization run in a research version of RayStation. A Matlab GUI for MC beamlet generation was developed, in which treatment parameters such as the pencil beam size and spacing, energy and number of beams can be selected. Treatment planning study for H'N and pelvis cases was performed and the effect of treatment parameters on the delivered dose distributions was evaluated and compared to the clinical treatment plans. The pelvis case with a 691cm3 PTV was treated with 2-arc 15MV VMAT and the H'N case with four PTVs with total volume of 531cm3 was treated with 4-arc 6MV VMAT. Results: Most studied VHEE plans outperformed VMAT plans. The best pelvis 80MeV VHEE plan with 25 beams resulted in 12% body dose sparing and 8% sparing to the bowel and right femur compared to the VMAT plan. The 100MeV plan was superior to the 150MeV plan. Mixing 100 and 150MeV improved dose sparing to the bladder by 7% compared to either plan. Plans with 16 and 36 beams did not significantly affect the dose distributions compared to 25 beam plans. The best H'N 100MeV VHEE plan decreased mean doses to the brainstem, chiasm, and both globes by 10-42% compared to the VMAT plan. Conclusion: The pelvis and H'N cases suggested that sixteen 100MeV beams might be sufficient specifications of a novel VHEE treatment machine. However, optimum machine parameters will be determined with the presented VHEE treatment-planning tool for a large number of clinical cases. BW Loo and P Maxim received research support from RaySearch Laboratories. E Hynning and B Hardemark are employees of

  4. Evaluation of the antibiotic activity and genetic mutation of microorganisms in the effluent treated with the electron-beam from waste-water treatment plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hun; Nam, Ji Hyun; Shin, Ji Hye; Yun, Seo Yeon; Cho, Young Cheol; Oh, Kyoung hee [Chungbuk National University, Cheongju (Korea, Republic of)

    2011-04-15

    In this study, the residual concentrations and activities of antibiotics after UV or gamma-ray treatments were estimated, and the effect of irradiation of UV, gamma-ray, or electron beam was estimated on the survivability and less mutagenic effect on bacteria. The changes of bacterial communities and radiation resistant population in the effluent treated with UV and electron-beam were analyzed. The gamma-ray irradiation was more effective than UV in degradation of antibiotics. The extent of mutagenicity of electron-beam irradiation was less than those of UV or gamma-ray irradiations. The application of election-beam to the wastewater treatment system showed the high efficiency of destroying and removal effects on bacterial cells. The selective increase in population of radiation resistant bacteria was not observed. These results indicate that the application of ionizing radiation to the processes of wastewater treatment system will be suitable than UV irradiation because of its degradability of variable antibiotics, high removal rate of harmful bacteria, less mutagenicity of bacteria, and low selective effect on radiation resistant bacteria

  5. In vivo dosimetric study for a jaw-solitary-bony plasmacytomas-electron-beam-therapy;Estudo dosimetrico in vivo para terapia com eletrons em caso de plasmocitoma osseo solitario em mandibula

    Energy Technology Data Exchange (ETDEWEB)

    Biazotto, Bruna [Universidade Estadual de Campinas (HC/FCM/UNICAMP), SP (Brazil). Fac. de Ciencias Medicas. Hospital de Clinicas; Ferreira, Valeria A.; Ferrari, Vilma [Universidade Estadual de Campinas (HC/UNICAMP), SP (Brazil). Hospital de Clinicas. Servico de Radioterapia

    2009-07-01

    Some superficial tumors are treated with high energy electron beams. The dose distribution is rather complex, due to the beam crossing different electronic densities' materials. In the present work, the dose distribution in a jaw's-solitary-bony-plasmacytomas-treatment has been studied, to which 15 MeV electron beam was, initially, prescribed. Using lithium fluoride thermoluminescent dosimeters, the dose was evaluated on skin surface, behind the jaw, and, also, behind a lead shield designed to oral cavity protection. It was determined that the dose transmitted through the shield was 16% of the prescription dose, equivalent to 32 cGy, and, according to the medical staff, the treatment was modified to the 12 MeV-energy, resulting in a reduction to 8 cGy. It was assessed the influence of electron backscattering, resulting in a increase of the bolus thickness around the lead. (author)

  6. Phase composition in NiTi near-surface layers after electron beam treatment and its variation depending on beam energy density

    Energy Technology Data Exchange (ETDEWEB)

    Ostapenko, Marina G., E-mail: artifakt@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055, Russia and National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Meisner, Ludmila L., E-mail: llm@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055, Russia and National Research Tomsk State University, Tomsk, 634050 (Russian Federation); Lotkov, Aleksandr I., E-mail: lotkov@ispms.tsc.ru, E-mail: egu@ispms.tsc.ru; Gudimova, Ekaterina Y., E-mail: lotkov@ispms.tsc.ru, E-mail: egu@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation)

    2014-11-14

    In the work, we study the mechanisms of structural phase state formation in NiTi surface layers after low-energy pulsed electron beam irradiation depending on the electron beam energy density. It is revealed that after electron beam treatment of the NiTi specimens at energy densities E{sub 1} = 15 J/cm{sup 2}, E{sub 2} = 20 J/cm{sup 2}, and E{sub 3} = 30 J/cm{sup 2}, a series of effects is observed: the absence of the Ti2Ni phase and the presence of new peaks correspond to the B19′ martensite phase with monoclinic structure. Estimation of the relative volume content of the B2 and B19′ phases from the total intensity of their peaks shows that the percentage of the martensite phase increases from ∼5 vol.% in the NiTi specimen irradiated at E{sub 1} = 15 J/cm{sup 2} to ∼80 vol.% in the NiTi specimen irradiated at E{sub 3} = 30 J/cm{sup 2}. It is found that in the NiTi specimens irradiated at E ≤ 20 J/cm{sup 2}, the layer that contains a martensite phase resides not on the surface but at some depth from it.

  7. Sheet electron beam tester

    Science.gov (United States)

    Spear, Alexander Grenbeaux

    The DARPA HiFIVE project uses a pulsed electron sheet beam gun to power a traveling wave tube amplifier operating at 220 GHz. Presented is a method for characterizing the high current density 0.1 mm by 1 mm sheet electron beam. A tungsten tipped probe was scanned through the cross section of the sheet electron beam inside of a vacuum vessel. The probe was controlled with sub-micron precision using stepper motors and LabView computer control while boxcar averaging hardware sampled the pulsed beam. Matlab algorithms were used to interpret the data, calculate beam dimensions and current density, and create 2-dimensional cross section images. Full characterization of two separate HiFIVE sheet electron guns was accomplished and is also presented.

  8. Electron Beam Materials Processing

    Science.gov (United States)

    Powers, Donald E.

    2012-06-01

    In electron beam processing, a well-defined beam of relatively energetic electrons produced by a high voltage acceleration gap is used to transmit thermal energy into a material in a precise manner. This controlled deposition of heat is employed in a wide variety of industrial applications for precision cutting, drilling, and welding of materials as well as annealing, glazing, and surface hardening. This chapter will describe the equipment used and the most prominent industrial applications for this process.

  9. Single-dose electron beam irradiation in treatment and prevention of keloids and hypertrophic scars

    Energy Technology Data Exchange (ETDEWEB)

    Lo, T.C.M.; Salzman, F.A. (Lahey Clinic Medical Center, Burlington (USA). Department of Radiation Oncology); Seckel, B.R. (Lahey Clinic Medical Center, Burlington (USA). Department of Plastic and Reconstructive Surgery); Wright, K.A. (Massachusetts Institute of Technology, Cambridge (USA). High Voltage Research Laboratory)

    1990-11-01

    Low megavolt electron beam irradiation was used on 354 sites in 199 patients at Lahey Clinic either for palliation of symptomatic hypertrophic scars or as post operative irradiation in an attempt to prevent formation or recurrence of hypertrophic scars. Electron energies used ranged from 1.5 to 3.5 MeV. The median age of the 59 male patients was 22 years and of the 140 female patients 35 years. All patients had at least one follow-up visit, and the median follow-up was 35 months. Of the 294 sites treated for the first time, 272 were irradiated with a single fraction with a skin dose ranging from 2 to 20 Gy. Of the 85 sites in 63 patients without excision of symptomatic hypertrophic scars, single-dose electron beam irradiation was of clinically significant value in only 41 sites. No patients have been treated without surgical excision since 1973. Because of a history of formation of hypertrophic scars elsewhere in the body, 13 patients with 19 incisions were treated prophylactically after operation for other diseases. All sites were irradiated with single doses ranging from 8 to 20 Gy, and hypertrophic scars did not subsequently develop in any patient. Altogether, 119 patients with 174 sites were irradiated after surgical excision of hypertrophic scars to prevent recurrence; 168 sites received singe-fraction irradiation, and 161 received a dose of 8 Gy greater, up to 15 Gy. No statistically significant differences were observed in complete success rates, ranging from 82 to 90 per cent with doses of 9 Gy or greater. An interval of up to 72h between excision and single-fraction irradiation satisfactorily prevented recurrence, and clinically significant chronic telangiectasia was recorded in only one patient. Postoperative low megavolt electron beam irradiation with a single dose of 9 Gy or greater is highly effective in the prevention of formation recurrence of hypertrophic scars or keloids.

  10. Successful treatment of skin infiltration in childhood hematological malignancies with total skin electron beam therapy. A report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Ohkawa, Masahito; Shikano, Takaaki; Ueno, Norihiro; Tsujii, Hirohiko; Tono-oka, Tatsuhito; Matsumoto, Takahide.

    1988-07-01

    Two children with cutaneous lymphoma and leukemia who were treated with total skin electron beam therapy (TSEB) are described here. Patient 1. A 7-year-old boy was admitted because of a mass over the bilateral parotis and anemia. The white blood cell count on admission was 5,000/ul. Bone marrow examination revealed 70 per cent monoblasts (M5a type by FAB classification). Complete remission was obtained following the regimen of daunomycin, cytosine arabinoside, 6-mercaptopurine and prednisolone. He was again admitted because of a skin nodule on the left thigh 19 months after initial diagnosis. A biopsy of the skin nodule demonstrated monoblastic infiltration. He received 20 Grays (Gy) to the left thigh and this led to resolution of the skin nodule. At that time, other skin nodules appeared on the right upper and lower extremities. He was treated with TSEB. Daily doses of 1 Gy were given twice a week with a 4 MeV electron beam and a total dose of 10 Gy was administered over a period of 4 weeks. Although he again had a isolated skin relapse on the right shoulder, he remained in remission for 6 years after completing TSEB. Patient 2. A 6-year-old boy was admitted because of multiple skin lesions. Physical examination revealed 22 discrete, indurated skin nodules. a biopsy of a skin nodule demonstrated lymphoblast infiltration, confirming the diagnosis of B cell cutaneous lymphoma (stage IV). He was treated with CHOP (consisting of cyclophosphamide, adriamycin, vincristine and prednisolone). After two courses of CHOP therapy, he was treated with TSEB using the same technique described above. To date, the patient remains in remission 5 years after initial diagnosis.

  11. The consequences of physical post-treatments (microwave and electron-beam) on food/packaging interactions: A physicochemical and toxicological approach.

    Science.gov (United States)

    Riquet, A M; Breysse, C; Dahbi, L; Loriot, C; Severin, I; Chagnon, M C

    2016-05-15

    The safety of microwave and electron-beam treatments has been demonstrated, in regards to the formation of reaction products that could endanger human health. An integrated approach was used combining the potential toxicity of all the substances likely to migrate to their chemical characterizations. This approach was applied to polypropylene (PP) films prepared with a selection of additives. Components were identified by liquid and gas chromatography using a mass selective detector system. Their potential toxicity was assessed using three in vitro short-term bioassays and their migrations were carried out using a standards-based approach. After the electron-beam treatment some additives decomposed and there was a significant increase in the polyolefin oligomeric saturated hydrocarbons concentration. PP prepared with Irgafos 168 led to a significantly strong cytotoxic effect and PP prepared with Irganox 1076 induced a dose-dependant estrogenic effect in vitro. Migration values were low and below the detection limit of the analytical method applied. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Review of electron beam therapy physics.

    Science.gov (United States)

    Hogstrom, Kenneth R; Almond, Peter R

    2006-07-07

    For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed.

  13. Relativistic electron beams above thunderclouds

    DEFF Research Database (Denmark)

    Füellekrug, M.; Roussel-Dupre, R.; Symbalisty, E. M. D.

    2011-01-01

    Non-luminous relativistic electron beams above thunderclouds have been detected by the radio signals of low frequency similar to 40-400 kHz which they radiate. The electron beams occur similar to 2-9 ms after positive cloud-to-ground lightning discharges at heights between similar to 22-72 km above...... thunderclouds. Intense positive lightning discharges can also cause sprites which occur either above or prior to the electron beam. One electron beam was detected without any luminous sprite which suggests that electron beams may also occur independently of sprites. Numerical simulations show that beams...... of electrons partially discharge the lightning electric field above thunderclouds and thereby gain a mean energy of similar to 7MeV to transport a total charge of similar to-10mC upwards. The impulsive current similar to 3 x 10(-3) Am-2 associated with relativistic electron beams above thunderclouds...

  14. Direct writing of gold nanostructures with an electron beam: On the way to pure nanostructures by combining optimized deposition with oxygen-plasma treatment

    Directory of Open Access Journals (Sweden)

    Domagoj Belić

    2017-11-01

    Full Text Available This work presents a highly effective approach for the chemical purification of directly written 2D and 3D gold nanostructures suitable for plasmonics, biomolecule immobilisation, and nanoelectronics. Gold nano- and microstructures can be fabricated by one-step direct-write lithography process using focused electron beam induced deposition (FEBID. Typically, as-deposited gold nanostructures suffer from a low Au content and unacceptably high carbon contamination. We show that the undesirable carbon contamination can be diminished using a two-step process – a combination of optimized deposition followed by appropriate postdeposition cleaning. Starting from the common metal-organic precursor Me2-Au-tfac, it is demonstrated that the Au content in pristine FEBID nanostructures can be increased from 30 atom % to as much as 72 atom %, depending on the sustained electron beam dose. As a second step, oxygen-plasma treatment is established to further enhance the Au content in the structures, while preserving their morphology to a high degree. This two-step process represents a simple, feasible and high-throughput method for direct writing of purer gold nanostructures that can enable their future use for demanding applications.

  15. Direct writing of gold nanostructures with an electron beam: On the way to pure nanostructures by combining optimized deposition with oxygen-plasma treatment.

    Science.gov (United States)

    Belić, Domagoj; Shawrav, Mostafa M; Bertagnolli, Emmerich; Wanzenboeck, Heinz D

    2017-01-01

    This work presents a highly effective approach for the chemical purification of directly written 2D and 3D gold nanostructures suitable for plasmonics, biomolecule immobilisation, and nanoelectronics. Gold nano- and microstructures can be fabricated by one-step direct-write lithography process using focused electron beam induced deposition (FEBID). Typically, as-deposited gold nanostructures suffer from a low Au content and unacceptably high carbon contamination. We show that the undesirable carbon contamination can be diminished using a two-step process - a combination of optimized deposition followed by appropriate postdeposition cleaning. Starting from the common metal-organic precursor Me2-Au-tfac, it is demonstrated that the Au content in pristine FEBID nanostructures can be increased from 30 atom % to as much as 72 atom %, depending on the sustained electron beam dose. As a second step, oxygen-plasma treatment is established to further enhance the Au content in the structures, while preserving their morphology to a high degree. This two-step process represents a simple, feasible and high-throughput method for direct writing of purer gold nanostructures that can enable their future use for demanding applications.

  16. Electron beam silicon purification

    Energy Technology Data Exchange (ETDEWEB)

    Kravtsov, Anatoly [SIA ' ' KEPP EU' ' , Riga (Latvia); Kravtsov, Alexey [' ' KEPP-service' ' Ltd., Moscow (Russian Federation)

    2014-11-15

    Purification of heavily doped electronic grade silicon by evaporation of N-type impurities with electron beam heating was investigated in process with a batch weight up to 50 kilos. Effective temperature of the melt, an indicative parameter suitable for purification process characterization was calculated and appeared to be stable for different load weight processes. Purified material was successfully approbated in standard CZ processes of three different companies. Each company used its standard process and obtained CZ monocrystals applicable for photovoltaic application. These facts enable process to be successfully scaled up to commercial volumes (150-300 kg) and yield solar grade silicon. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Effect of Prior and Post-Weld Heat Treatment on Electron Beam Weldments of (α + β) Titanium alloy Ti-5Al-3Mo-1.5V

    Science.gov (United States)

    Anil Kumar, V.; Gupta, R. K.; Manwatkar, Sushant K.; Ramkumar, P.; Venkitakrishnan, P. V.

    2016-06-01

    Titanium alloy Ti5Al3Mo1.5V is used in the fabrication of critical engine components for space applications. Double vacuum arc re-melted and (α + β) forged blocks were sliced into 10-mm-thick plates and subjected to electron beam welding (EBW) with five different variants of prior and post-weld heat treatment conditions. Effects of various heat treatment conditions on the mechanical properties of the weldments have been studied. The welded coupons were characterized for microstructure, mechanical properties, and fracture analysis. An optimized heat treatment and welding sequence has been suggested. Weld efficiency of 90% could be achieved. Weldment has shown optimum properties in solution treated and aged condition. Heat-affected zone adjacent to weld fusion line is found to have lowest hardness in all conditions.

  18. Evolution of Structural-Phase States in TiNi Surface Layers Synthesized by Electron Beam Treatment

    Directory of Open Access Journals (Sweden)

    L. L. Meisner

    2010-01-01

    Full Text Available The paper presents the results of X-ray diffraction analysis of nonequilibrium structural and elastic stress states in TiNi surface layers irradiated by low-energy electron beams. It is found that a surface layer with a mixed (2D columnar and 3D equiaxial submicrocrystalline structure is formed on the irradiated side of the TiNi specimens, and the volume fractions of the two structure types depend on the beam energy parameters and number of pulses. The B2 phase synthesized in the layer is characterized by lattice microstrain due to stresses of the first and second kinds (εI≈±1%, εII=0.25%, and the layer as such is an internal stress concentrator for underlying layers of the material. In the intermediate layer beneath the stress concentrator, relaxation of irradiation-induced internal stress takes place. It is shown that the main mechanism of the relaxation is partial B2→B19′ martensite transformation. The B19′ martensite phase in the intermediate layer decreases the microstrain in the conjugate B2 phase. The thickness of the layer in which the relaxation processes develop through the B2→B19′ martensite transformation is 10–15 μm.

  19. Determination of microbial contamination of plastic cups for dairy products and utilization of electron beam treatment for sterilization.

    Science.gov (United States)

    Tacker, M; Hametner, C; Wepner, B

    2002-01-01

    Packaging materials are often considered a critical control point in HACCP systems of food companies. Methods for the determination of the microbial contamination rate of plastic cups, especially for dairy products, must reliably detect single moulds, yeasts or coliforms. In this study, a comparison of a specially adapted coating method, impedance method, direct inoculation and membrane filter technique was carried out to determine contamination with yeasts, moulds, coliforms and total bacterial counts using the appropriate agar in each case. The coating method is recommended for determining yeasts, moulds and coliforms as it allows the localization of the microorganisms as well as the determination of single microorganisms. For total bacterial count, a direct inoculation technique is proposed. The employing of simple measures in the production and during transport of packaging materials, such as dust-prevention or tight sealing in polyethylene bags, heavily reduces microbial contamination rates of packaging material. To reduce contamination rates further, electron beam irradiation was applied: plastic cups sealed in polyethylene bags were treated with 4-5 kGy, a dose that already leads to sterile polystyrene and polypropylene cups without influencing mechanical characteristics of the packaging material.

  20. Portable electron beam weld chamber

    Science.gov (United States)

    Lewis, J. R.; Dimino, J. M.

    1972-01-01

    Development and characteristics of portable vacuum chamber for skate type electron beam welding are discussed. Construction and operational details of equipment are presented. Illustrations of equipment are provided.

  1. Surface nanostructure and improved microhardness of 40CrNiMo7 steel induced by high current pulsed electron beam treatment

    Science.gov (United States)

    Wang, Huihui; Hao, Shengzhi

    2017-07-01

    In this paper, surface modification of 40CrNiMo7 steel was investigated with high current pulsed electron beam (HCPEB) treatment. The scanning electron microscope (SEM), electron back-scattered diffraction (EBSD), electron probe micro analysis (EPMA), transmission electron microscopy (TEM) and X-ray diffraction (XRD) results show that a composite microstructure of mainly refined austenite and a little martensite was produced in the surface modified layer of depth ∼7 μm. The average size of small cells on modified surface was decreased to ∼120 nm after 25 HCPEB pulses. XRD analysis indicates a preferred orientation of austenite (2 2 0) crystal plane, and TEM results show the broken and dissolved cementite in the surface modified layer. After HCPEB treatment, all the samples exhibited a remarkable improvement in surface microhardness measurement, up to ∼1000 HK for 15 HCPEB pulses, as tripled of the initial 40CrNiMo7 steel.

  2. Effect of two virus inactivation methods. Electron beam irradiation and binary ethylenimine treatment on determination of reproductive hormones in equine plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kyvsgaard, N.C.; Nansen, P. [The Royal Veterinary and Agricultural Univ., Danish Centre for Experimental Parasitology, Frederiksberg (Denmark); Hoeier, R.; Brueck, I. [The Royal Veterinary and Agricultural Univ., Dept. of Clinical Studies, Section of Reproduction, Frederiksberg (Denmark)

    1997-12-31

    Ionizing irradiation and binary ethylenimine treatment have previously been shown to be effective for in-vitro inactivation of virus in biological material. In the present study the 2 methods were tested for possible effects on measurable concentrations of reproductive hormones in equine plasma (luteinizing hormone (LH), follicle-stimulating hormone (FSH), progesterone (P{sub 4}), and oestradiol-17 {beta} (E{sub 2})). The inactivation methods were electron beam irradiation with a dose from 11 to 44 kGy or treatment with binary ethylenimine (BEI) in concentrations of 1 and 5 mmol/L. Generally, there was a close correlation (r>0.8, p<0.001) between pre- and post-treatment hormone levels. Thus, the different phases of the oestrous cycle could be distinguished on the basis of measured hormone concentrations of treated samples. However, both treatments significantly changed hormone concentrations of the plasma samples. For LH, FSH, and E{sub 2} the effect of irradiation and BEI treatment was depressive and dose-dependant. For P{sub 4} the effect of irradiation was also depressive and dose-dependant. However, the highest dose of BEI resulted in an increase of measured P{sub 4} concentration, which may be attributed to changes in the plasma matrix due to the treatment. Although the treatments affected measured hormone concentrations, the close correlation between pre-treatment and post-treatment measurements means that the diagnostic value will remain unchanged. (au). 17 refs.

  3. Producing nano-grained and Al-enriched surface microstructure on AZ91 magnesium alloy by high current pulsed electron beam treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Shengzhi, E-mail: ebeam@dlut.edu.cn; Li, Mincai

    2016-05-15

    Highlights: • HCPEB surface treatment was conducted on AZ91 magnesium alloy. • Surface modified microstructure and phase composition were characterized. • Preferential evaporation of Mg and dissolution of Mg{sub 17}Al{sub 12} phase occurred. • Nano-grained and Al-enriched surface layer was produced of depth ∼8 μm. • Surface microhardness and corrosion resistance were improved simultaneously. - Abstract: Surface treatment of AZ91 magnesium alloy was carried out by high current pulsed electron beam (HCPEB) with accelerating voltage 27 kV and energy density 3 J/cm{sup 2}. The surface microstructure and phase composition were characterized by using optical microscope (OM), X-ray diffraction (XRD), and scanning electron microscope (SEM) equipped with energy dispersive spectrometer (EDS). The surface microhardness and corrosion resistance were measured. Under HCPEB treatments, the preferential evaporation of Mg element occurred intensively on irradiated surface and the initial large Mg{sub 17}Al{sub 12} phases were dissolved. The nano-grained and Al-enriched surface modified layer was ultimately formed of depth ∼8 μm. According to the testing results, the surface microhardness increased from 63 to 141 HK after 30 pulses of HCPEB treatment, while the best improvement of corrosion resistance was obtained by 15 pulses of HCPEB treatment with a cathodic current density decreased by two orders of magnitude as compared with the initial AZ91 sample.

  4. METHOD OF ELECTRON BEAM PROCESSING

    DEFF Research Database (Denmark)

    2003-01-01

    As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which is the o......As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which...... exploiting the potential of electron beam processing to a greater degree than previously possible, for example by means of electron beam welding...

  5. Intense Relativistic Electron Beam Investigations

    Science.gov (United States)

    1979-04-01

    dif- fusion pump furnished with the electron beam machine was sized to hold vacuum rathcr thani to ,achieve rapid pump down, we were limited to 2 or...camera and lasers as well as providing an advance synchronized trigger pulse to the oscilloscopes. Since this water filled spark gap switch initiates...Equipment Source NRL 0.5 XeV 7 ohm relativistic "electron beam machine Government furnished Capacitor bank and magnetic field solenoid 4’ long with

  6. Effect of Heat Treatment on Low Temperature Toughness of Reduced Pressure Electron Beam Weld Metal of Type 316L Stainless Steel

    Science.gov (United States)

    Nakagawa, H.; Fujii, H.; Tamura, M.

    2006-03-01

    Austenitic stainless steels are considered to be the candidate materials for liquid hydrogen vessels and the related equipments, and those welding parts that require high toughness at cryogenic temperature. The authors have found that the weld metal of Type 316L stainless steel processed by reduced pressure electron beam (RPEB) welding has high toughness at cryogenic temperature, which is considered to be due to the single-pass welding process without reheating effect accompanied by multi-pass welding process. In this work, the effect of heat treatment on low temperature toughness of the RPEB weld metal of Type 316L was investigated by Charpy impact test at 77K. The absorbed energy decreased with higher temperature and longer holding time of heat treatment. The remarkable drop in the absorbed energy was found with heat treatment at 1073K for 2 hours, which is as low as that of conventional multi-pass weld metal such as tungsten inert gas welding. The observations of fracture surface and microstructure revealed that the decrease in the absorbed energy with heat treatment resulted from the precipitation of intermetallic compounds near delta-ferrite phase.

  7. Special features of electron-beam boronizing of steels

    Science.gov (United States)

    Sizov, I. G.; Smirnyagina, N. N.; Semenov, A. P.

    1999-12-01

    Electron-beam treatment is a promising method of surface treatment. It can be used in traditional technological operations, i.e., melting, welding, soldering, facing, quenching, and annealing, and in new processes, i.e., polymerization, local change of magnetic properties, recrystallization of the surface layer, zonal melting, etc. Chemical heat treatment of a metal surface with a daubing applied by means of a powerful electron beam is an interesting technique. By varying the composition of the daubing we can change the properties of the metal surface (wear resistance, corrosion strength, high-temperature strength, etc.). Electron-beam heating has some advantages over laser treatment, namely, (1) a high coefficient of the absorption of electron beam by the metal, which makes it possible to treat the surface effectively without absorbing coatings, (2) simplicity of organization of rapid scanning of the treated surface by the electron beam, (3) high efficiency of the electron gun (up to 70-80%), (4) the possibility of creating quite compact technological electron-beam units with a power of tens and hundreds of kilowatts, (5) treatment in vacuum. In this connection interest in works in this field has grown. The present paper concerns results of a study of the structure and properties of boronized layers deposited on carbon steels by the method of electron-beam treatment under vacuum and by the traditional method for comparison.

  8. Electron beam radiation for conjunctival squamous carcinoma.

    Science.gov (United States)

    Graue, Gerardo F; Tena, Lawrence B; Finger, Paul T

    2011-01-01

    To describe the authors' technique and preliminary results using electron beam radiation as rescue therapy for recalcitrant squamous cell carcinoma of the conjunctiva and cornea. A retrospective review comprised of an interventional case series of patients with pathologically confirmed diagnosis of squamous cell carcinoma of the conjunctiva and cornea, who had failed multiple standard treatments and underwent electron beam radiation therapy. Outcomes, radiation-related complications, and adverse effects were documented. Mortality and local control rates were calculated by the Kaplan-Meier survival probability method. Eight patients met the inclusion criteria; of these, 6 (75%) were men and 2 (25%) were women, with ages ranging from 38 to 65 years (mean 50 years). One tumor (12.5%) was classified as T2N0M0, 6 (75%) were classified as T3N0M0, and one (12.5%) was classified as T4N0M0. Follow up from electron beam radiation therapy ranged from 3 to 72 months (mean 30.25 months). The most common side effect was erythema and edema of the eyelids with diffuse transient eyelash loss, seen in all patients. Tumor local control and regression after electron beam radiation therapy were noted in 6 patients (75%); recurrence was noted in 2. There was neither metastatic spread nor tumor-related deaths. The authors report a small case series where local tumor control was achieved with electron beam radiation therapy for recalcitrant squamous cell carcinoma of the conjunctiva and cornea. This approach may be considered for patients who fail conventional therapy.

  9. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  10. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova-Carter, Magdalena; Qu, Bradley; Palma, Bianey; Jensen, Christopher; Maxim, Peter G., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu; Loo, Billy W., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Hårdemark, Björn; Hynning, Elin [RaySearch Laboratories AB, Stockholm SE-103 65 (Sweden)

    2015-05-15

    Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric

  11. Study the sensitivity of dose calculation in prism treatment planning system using Monte Carlo simulation of 6 MeV electron beam

    Science.gov (United States)

    Hardiansyah, D.; Male, S.; Haryanto, F.

    2014-09-01

    Prism is a non-commercial Radiotherapy Treatment Planning System (RTPS) develop by Ira J. Kalet from Washington University. Inhomogeneity factor is included in Prism TPS dose calculation. The aim of this study is to investigate the sensitivity of dose calculation on Prism using Monte Carlo simulation. Phase space source from head linear accelerator (LINAC) for Monte Carlo simulation is implemented. To achieve this aim, Prism dose calculation is compared with EGSnrc Monte Carlo simulation. Percentage depth dose (PDD) and R50 from both calculations are observed. BEAMnrc is simulated electron transport in LINAC head and produced phase space file. This file is used as DOSXYZnrc input to simulated electron transport in phantom. This study is started with commissioning process in water phantom. Commissioning process is adjusted Monte Carlo simulation with Prism RTPS. Commissioning result is used for study of inhomogeneity phantom. Physical parameters of inhomogeneity phantom that varied in this study are: density, location and thickness of tissue. Commissioning result is shown that optimum energy of Monte Carlo simulation for 6 MeV electron beam is 6.8 MeV. This commissioning is used R50 and PDD with Practical length (Rp) as references. From inhomogeneity study, the average deviation for all case on interest region is below 5 %. Based on ICRU recommendations, Prism has good ability to calculate the radiation dose in inhomogeneity tissue.

  12. Shimmed electron beam welding process

    Science.gov (United States)

    Feng, Ganjiang; Nowak, Daniel Anthony; Murphy, John Thomas

    2002-01-01

    A modified electron beam welding process effects welding of joints between superalloy materials by inserting a weldable shim in the joint and heating the superalloy materials with an electron beam. The process insures a full penetration of joints with a consistent percentage of filler material and thereby improves fatigue life of the joint by three to four times as compared with the prior art. The process also allows variable shim thickness and joint fit-up gaps to provide increased flexibility for manufacturing when joining complex airfoil structures and the like.

  13. SU-E-T-474: Improvements to Intra-Oral Shield Design for Electron Beam Treatments: Use of Multi-Layered Metal Foils

    Energy Technology Data Exchange (ETDEWEB)

    Butson, M

    2015-06-15

    Purpose: Intraoral electron shields used in radiotherapy are designed to minimize radiation exposure to non-treatment tissue. Sites where shields are used include but are not limited to, the treatment of lips, cheeks and ears whilst shielding the underlying oral cavity, tongue, gingival or temporal region. However their use produces an enhancement in dose on the beam side caused by an increase in electron backscatter radiation. This work designs a new shield incorporating copper, aluminium and wax in a step down filter arrangement to minimise backscatter whilst minimizing overall shield thickness. Methods: For electron beams ranging from 6 MeV to 10 MeV, shields of varying designs and thicknesses were assessed to determine the thinnest shield design that could be produced whilst minimising backscattered radiation to a clinically acceptable level. This was performed with conventional lead and wax shields as well as varying quantities of aluminium and copper foils. Results: From tested shield designs, a new shield design of 4 mm lead, 0.6 mm copper, 1.0 mm aluminium and 1.5 mm wax (3.1 mm added filtration, 7.1 mm total thickness) provided a clinically acceptable (no greater than 110% dose) backscatter and transmission reduction and matched a standard 4.5 mm lead and 10 mm wax (total thickness 14.5 mm) electron shield. Dose enhancement values of no more than 10 % were measured utilising this shield design with a 50 % reduction in shield thickness. Conclusion: The thinner layered shield reduced backscattered radiation dose to less than 10% enhancement for beam energies on 10 MeV and less and will allow easier patient set up. The thinner shields are tolerated better by patients when mucosal reactions occur as they place less physical pressure on these sites during treatment due to their smaller size and thickness.

  14. Effect of electron beam on in vitro cultured orchid organs

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jaihyunk; Bae, Seho; Bae, Changhyu [Sunchon National Univ., Suncheon (Korea, Republic of); Kang, Hyun Suk; Lee, Byung Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-07-01

    Ionizing radiations have been effective mutagen sources to overcome the limitation of the useful genetic resources in natural environment. The study was conducted to investigate an effect of electron beam on organogenesis, growth patterns and genetic variation in the irradiated orchid organs. The in utero cultured rhizomes of orchids were irradiated with the electron beam in the dose range of 15Gy to 2240Gy under the condition of various beam energy and beam current. Significant decreases in survival, growth and organogenesis were observed by increase of intensity of electron beam irradiation. The irradiation intensity of lethal dose 50 of the in utero cultured orchid was estimated as approximately 500Gy to 1000Gy under 10MeV/n, and 1000Gy was optimal for growth and organogenesis of the cultures under 10MeV/n with 0.05mA treatment, and 15Gy {approx} 48Gy under 2MeV/n and 0.5mA electron beam condition. RAPD and ISSR analyses for the electron beam irradiated organs were performed to analyze genetic variation under the electron beam condition. Both of RAPD and ISSR analyses showed higher polymorphic rate in the electron-beam irradiated C. gangrene and C. Kaner.

  15. Electron beam micromachining of plastics

    Czech Academy of Sciences Publication Activity Database

    Dupák, Libor

    2014-01-01

    Roč. 49, 5-6 (2014), s. 310-314 ISSN 0861-4717 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA MŠk EE.2.3.20.0103 Institutional support: RVO:68081731 Keywords : micromachining of plastics * Electron beam Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  16. Mixed feed and its ingredients electron beam decontamination

    Science.gov (United States)

    Bezuglov, V. V.; Bryazgin, A. A.; Vlasov, A. Yu; Voronin, L. A.; Ites, Yu V.; Korobeynikov, M. V.; Leonov, S. V.; Leonova, M. A.; Tkachenko, V. O.; Shtarklev, E. A.; Yuskov, Yu G.

    2017-01-01

    Electron beam treatment is used for food processing for decades to prevent or minimize food losses and prolong storage time. This process is also named cold pasteurization. Mixed feed ingredients supplied in Russia regularly occur to be contaminated. To reduce contamination level the contaminated mixed feed ingredients samples were treated by electron beam with doses from 2 to 12 kGy. The contamination levels were decreased to the level that ensuring storage time up to 1 year.

  17. APPARATUS FOR ELECTRON BEAM HEATING CONTROL

    Science.gov (United States)

    Jones, W.H.; Reece, J.B.

    1962-09-18

    An improved electron beam welding or melting apparatus is designed which utilizes a high voltage rectifier operating below its temperature saturation region to decrease variations in electron beam current which normally result from the gas generated in such apparatus. (AEC)

  18. Computer simulation of electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Sabchevski, S.P.; Mladenov, G.M. (Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. po Elektronika)

    1994-04-14

    Self-fields and forces as well as the local degree of space-charge neutralization in overcompensated electron beams are considered. The radial variation of the local degree of space-charge neutralization is analysed. A novel model which describes the equilibrium potential distribution in overcompensated beams is proposed and a method for computer simulation of the beam propagation is described. Results from numerical experiments which illustrate the propagation of finite emittance overneutralized beams are presented. (Author).

  19. Practical Teaching about Electron Beams

    Science.gov (United States)

    Strawson, R. J.

    2009-01-01

    If you have seen tubes like the ones we describe here in the back of a cupboard but have been reluctant to use them, now is the time to get them out. The aim of this article is to record the history of teaching about electron beams, particularly with Teltron equipment, and in doing so encourage those schools that are equipped with these tubes to…

  20. High-dose electron beam sterilization of soft-tissue grafts maintains significantly improved biomechanical properties compared to standard gamma treatment.

    Science.gov (United States)

    Hoburg, A; Keshlaf, S; Schmidt, T; Smith, M; Gohs, U; Perka, C; Pruss, A; Scheffler, S

    2015-06-01

    Allografts have gained increasing popularity in anterior cruciate ligament (ACL) reconstruction. However, one of the major concerns regarding allografts is the possibility of disease transmission. Electron beam (Ebeam) and Gamma radiation have been proven to be successful in sterilization of medical products. In soft tissue sterilization high dosages of gamma irradiation have been shown to be detrimental to biomechanical properties of grafts. Therefore, it was the objective of this study to compare the biomechanical properties of human bone-patellar tendon-bone (BPTB) grafts after ebeam with standard gamma irradiation at medium (25 kGy) and high doses (34 kGy). We hypothesized that the biomechanical properties of Ebeam irradiated grafts would be superior to gamma irradiated grafts. Paired 10 mm-wide human BPTB grafts were harvested from 20 donors split into four groups following irradiation with either gamma or Ebeam (each n = 10): (A) Ebeam 25 kGy, (B) Gamma 25 kGy, (C) Ebeam 34 kGy (D) Gamma 34 kGy and ten non-irradiated BPTB grafts were used as controls. All grafts underwent biomechanical testing which included preconditioning (ten cycles, 0-20 N); cyclic loading (200 cycles, 20-200 N) and a load-to-failure (LTF) test. Stiffness of non-irradiated controls (199.6 ± 59.1 N/mm) and Ebeam sterilized grafts did not significantly differ (152.0 ± 37.0 N/mm; 192.8 ± 58.0 N/mm), while Gamma-irradiated grafts had significantly lower stiffness than controls at both irradiation dosages (25 kGy: 126.1 ± 45.4 N/mm; 34 kGy: 170.6 ± 58.2 N/mm) (p properties than gamma irradiation. Considering the results of this study and the improved control of irradiation application with electronic beam, this technique might be a promising alternative in soft-tissue sterilization.

  1. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  2. Welding multiple plies with an electron beam

    Science.gov (United States)

    Kiluk, F. J.

    1980-01-01

    Method for electron-beam welding of multi-ply metal sheets eliminates ply separation and minimizes porosity. Method was developed for assembling bellows made of four plies of iron/nickel alloy sheets. Method consists of making successive stitch welds with electron beam until weld seam is completely filled in and all plies have been penetrated.

  3. Viewing electron-beam welds in progress

    Science.gov (United States)

    Armenoff, C. T.

    1980-01-01

    With aid of optical filter, operator of electron-beam welding machine can view TV image of joint that is being welded and can make corrections as necessary. Operator can see when weld bead gets out of alinement, for example, and compensate for deflection of electron beam caused by changes in magnetic field.

  4. Magnetic Deflection Of Welding Electron Beam

    Science.gov (United States)

    Malinzak, R. Michael; Booth, Gary N.

    1991-01-01

    Electron-beam welds inside small metal parts produced with aid of magnetic deflector. Beam redirected so it strikes workpiece at effective angle. Weld joint positioned to where heavy microfissure concentration removed when subsequent machining required, increasing likelihood of removing any weld defects located in face side of electron-beam weld.

  5. Experimental Device for Electron Beam Micromachining

    Czech Academy of Sciences Publication Activity Database

    Dupák, Libor; Zobač, Martin; Dupák, Jan; Vlček, Ivan

    2006-01-01

    Roč. 41, 5-6 (2006), s. 272-275 ISSN 0861-4717. [EBT 2006 - International Conference on Electron Beam Technologies /8./. Varna, 05.06.2006-10.06.2006] Institutional research plan: CEZ:AV0Z20650511 Keywords : electron beam drilling * quartz glass Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  6. Gamma and electron-beam irradiation of cut flowers

    Science.gov (United States)

    Kikuchi, Olivia Kimiko

    2003-01-01

    Fresh cut flowers are commodities that require quarantine treatment for export/import. In the present work some cut flowers were irradiated in a gamma panoramic source and in an electron beam accelerator with doses up to 800 Gy, and the results for the radiation tolerance of the flowers are presented.

  7. Flue gas cleaning by multiple irradiation with electron beam

    Science.gov (United States)

    Paur, H.-R.; Baumann, W.; Mätzing, H.; Lindner, W.

    1995-09-01

    By electron beam treatment, NOx and SO2 can be reduced simultaneously from combustion flue gas. The efficiency of the process has been shown to improve by multiple irradiation. It appears most promising to perform the multiple irradiation with an intermediate gas scrubber. This paper reports experimental investigations on the efficiency of the intermediate filter.

  8. Design of 7 MeV electron beams for breast radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jon In; Kim, Jung In; Kwon, Hyuck Jun [Interdisplinary Program in Radiation Applied Life Science, Seoul National University Graduate School, Seoul (Korea, Republic of); Ha, Sung Whan; Kim, Il Han [Dept. of Radiation Oncology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Hyun Suk; Ye, Sung Joon [Program in Biomedical Radiation Sciences, Dept. of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of)

    2013-04-15

    For treating early stage breast cancer, breast conserving therapy with lumpectomy followed by radiation therapy has been preferred as the standard method Irradiation technique consists of whole breast irradiation of 50.0 Gy and supplemental boost of 10 Gy to the tumor bed. The 'boost' to supplement the dose to the highest risk breast tissue around the lumpectomy following whole breast irradiation (WBI) improves in-breast local control. Electron beams have been favored radiation as boost irradiation. Because of limited depth in electron beams, it is possible to reduce the dose for unwished organ such as lung and heart in located in deeper region. Traditionally, electron beams can be modified using a bolus. The use of bolus conforms 90% isodose curve of a single energy electron beam to the distal edge of the target volume. However, it often increases the skin dose with electron beams of energy below 10 MeV. Therefore, with an aim to simultaneously control the penetration depth of the electron beams and the skin dose, we produced the new 7 MeV electron beam by modulating 9 MeV electron beams available in clinical linear accelerators. In this study, we show that the 7 MeV electron beam is appropriate for treatment of patient with a tumor bed located in clinical depth (R90 – R80)

  9. Microstructural characteristics and mechanism of toughness improvement of laser and electron-beam welds of V-4Cr-4Ti following postwelding heat-treatment

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H.M.; Park, J.H.; Gazda, J.; Smith, D.L. [Argonne National Laboratory, IL (United States)

    1996-10-01

    The authors are conducting a program to develop an optimal laser welding procedure for large-scale fusion-reactor structural components to be fabricated from vanadium-base alloys. Microstructural characteristics were investigated by optical microscopy, X-ray diffraction, transmission electron microscopy, and chemical analysis to provide an understanding of the mechanism of the drastic improvement of impact toughness of laser and electron-beam (EB) welds of V-4Cr-4Ti following postwelding annealing at 1000{degrees}C. Transmission electron microscopy (TEM) revealed that annealed weld zones were characterized by extensive networks of fine V(C,O,N) precipitates, which appear to clean away O, C, and N from grain matrices. This process is accompanied by simultaneous annealing-out of the dense dislocations present in the weld fusion zone. It seems possible to produce high-quality welds under practical conditions by controlling and adjusting the cooling rate of the weld zone by some innovative method to maximize the precipitation of V(C,O,N).

  10. Focused electron beam induced deposition: A perspective

    Directory of Open Access Journals (Sweden)

    Michael Huth

    2012-08-01

    Full Text Available Background: Focused electron beam induced deposition (FEBID is a direct-writing technique with nanometer resolution, which has received strongly increasing attention within the last decade. In FEBID a precursor previously adsorbed on a substrate surface is dissociated in the focus of an electron beam. After 20 years of continuous development FEBID has reached a stage at which this technique is now particularly attractive for several areas in both, basic and applied research. The present topical review addresses selected examples that highlight this development in the areas of charge-transport regimes in nanogranular metals close to an insulator-to-metal transition, the use of these materials for strain- and magnetic-field sensing, and the prospect of extending FEBID to multicomponent systems, such as binary alloys and intermetallic compounds with cooperative ground states.Results: After a brief introduction to the technique, recent work concerning FEBID of Pt–Si alloys and (hard-magnetic Co–Pt intermetallic compounds on the nanometer scale is reviewed. The growth process in the presence of two precursors, whose flux is independently controlled, is analyzed within a continuum model of FEBID that employs rate equations. Predictions are made for the tunability of the composition of the Co–Pt system by simply changing the dwell time of the electron beam during the writing process. The charge-transport regimes of nanogranular metals are reviewed next with a focus on recent theoretical advancements in the field. As a case study the transport properties of Pt–C nanogranular FEBID structures are discussed. It is shown that by means of a post-growth electron-irradiation treatment the electronic intergrain-coupling strength can be continuously tuned over a wide range. This provides unique access to the transport properties of this material close to the insulator-to-metal transition. In the last part of the review, recent developments in mechanical

  11. Low Emittance Electron Beam Studies

    Energy Technology Data Exchange (ETDEWEB)

    Tikhoplav, Rodion [Univ. of Rochester, NY (United States)

    2006-01-01

    We have studied the properties of a low emittance electron beam produced by laser pulses incident onto an rf gun photocathode. The experiments were carried out at the A0 photoinjector at Fermilab. Such beam studies are necessary for fixing the design of new Linear Colliders as well as for the development of Free Electron Lasers. An overview of the A0 photoinjector is given in Chapter 1. In Chapter 2 we describe the A0 photoinjector laser system. A stable laser system is imperative for reliable photoinjector operation. After the recent upgrade, we have been able to reach a new level of stability in the pulse-to-pulse fluctuations of the pulse amplitude, and of the temporal and transverse profiles. In Chapter 3 we present a study of transverse emittance versus the shape of the photo-cathode drive-laser pulse. For that purpose a special temporal profile laser shaping device called a pulse-stacker was developed. In Chapter 4 we discuss longitudinal beam dynamics studies using a two macro-particle bunch; this technique is helpful in analyzing pulse compression in the magnetic chicane, as well as velocity bunching effects in the rf-gun and the 9-cell accelerating cavity. In Chapter 5 we introduce a proposal for laser acceleration of electrons. We have developed a laser functioning on the TEM*01 mode, a mode with a longitudinal electric field component which is suitable for such a process. Using this technique at energies above 40 MeV, one would be able to observe laser-based acceleration.

  12. Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films; Estudo do efeito da radiacao por feixe de eletrons nas propriedades de filmes de copoliester alifatico aromatico

    Energy Technology Data Exchange (ETDEWEB)

    Poveda, Patricia Negrini Siqueira

    2008-07-01

    Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex{sup R} and Ecobras{sup R}) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile properties for aromatic aliphatic copolyester. Structural changes of the samples (crosslinking or degradation) by SEM were not observed. The FT-IR identified the characteristic peaks of each involved functional group (copolyester and corn starch). However, it was not found bands of oxidation of the samples. In the DSC, changes in the melting temperature of the irradiated Ecoflex{sup R} and Ecobras{sup R} samples, was not identified when compared with the samples of reference. However, it was verified a reduction in the melting enthalpy of the Ecobras{sup R} samples after irradiation. The Ecobras{sup R} material presented crosslinking, when submitted to doses of 10 kGy and 40 kGy. The Ecoflex{sup R} material did not present crosslinking when submitted to these doses. The biodegradability of the materials was evaluated by two methods of test: soil simulated and enzymatic. In both methods, the irradiated samples presented faster biodegradation than the references not irradiated. (author)

  13. Material Protection During Electron-Beam Welding

    Science.gov (United States)

    Tomlinson, R. L.; Kiluk, F. J.

    1982-01-01

    Alumina pellets behind electron-beam weld joint protect other parts of assembly from beam and from spattered material. Alumina pellets may be cleaned and reused. Easily applied and removed in regions that are narrow or have complex shapes.

  14. Electron beam welding complex diagnostics automated system

    Directory of Open Access Journals (Sweden)

    Є. В. Нікітенко

    2013-07-01

    Full Text Available The structure of the system of technical diagnostics is investigated. The algorithm of technical diagnostic of electron beam welding complex, which serves as the basis for creation of automated system for technical diagnostics, is proposed

  15. Metamaterial light sources driven by electron beams

    OpenAIRE

    ADAMO, G.; MacDonald, K. F.; De Angelis, F.; Di Fabrizio, E.; Zheludev, N. I.

    2011-01-01

    We demonstrate a new generation of free-space and fibre-coupled tuneable light sources based on nanostructured photonic metamaterials driven by free-electrons beams. Emission wavelengths are determined by metamaterial resonant modes and electron energies

  16. Influence of heat treatment on the mechanical and electrical characteristics of Ni{sub 0.5}Ti{sub 0.5} alloy prepared by electron-beam melting

    Energy Technology Data Exchange (ETDEWEB)

    Ammar, A.H. [Thin Film Laboratory, Physics Department, Faculty of Education, Ain Shams University (Egypt); Physics Department, Faculty of Science and Arts, Al-Ola, Taibah University (Saudi Arabia); Al-Buhairi, M. [Physics Department, Faculty of Science, Taiz University (Yemen); Farag, A.A.M., E-mail: alaafaragg@yahoo.com [Thin Film Laboratory, Physics Department, Faculty of Education, Ain Shams University (Egypt); Al-Wajeeh, N.M.M. [Physics Department, Faculty of Science, Taiz University (Yemen)

    2013-06-15

    Nickel titanium alloys (Ni{sub 0.5}Ti{sub 0.5}) were successfully produced from elemental Ni/Ti powders by electron-beam melting method and then subjected to annealing and aging treatment. Microstructure of the alloys was examined by XRD and SEM. The mechanical properties of the alloyed surface were examined. The microhardness was studied as a function of annealing temperature and time. It was found that the microhardness decreases with increasing annealing temperature until 660 °C after which the microhardness increases. Electrical resistance measurements were carried out in order to study the transformation behavior. The electrical measurements point out the importance of temperature dependence of Ni{sub 0.5}Ti{sub 0.5} electrical resistance for the identification of particular transformation. The influence of aging on the development of electrical resistivity was also investigated.

  17. Ion chromatographic determination of SO{sub 2} and SO{sub 3} in flue gases in pilot plant of removal of SO{sub 2} and NO{sub x} by electron beam treatment

    Energy Technology Data Exchange (ETDEWEB)

    Polkowska-Motrenko, H.; Kulisa, K.; Dybczynski, R. [Department of Analytical Chemistry, Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1998-12-31

    A method for the simultaneous determination of SO{sub 2} and SO{sub 3} in combustion flue gases from a coal-fired electric plant was elaborated. SO{sub 2} and SO{sub 3} were collected by absorbing the gases in alkaline aqueous solutions and determined by ion chromatography as sulfite and sulfate. The collection efficiency was practically 100%. Precision and accuracy of the method have been discussed. The method was used to control the content of SO{sub 2} and SO{sub 3} in flue gases from the pilot plant for removal of SO{sub 2} and NO{sub x} by electron beam treatment at the heat and power generating plant (HPGP) Kaweczyn. (author) 18 refs, 5 figs, 2 tabs

  18. Survey on electron beam processing technologies

    Science.gov (United States)

    Yasui, S.; Sunabe, K.; Inaba, T.

    1990-06-01

    The developing situation is studied of electron beam processing technologies and the future problems are shown when these are utilized for electric power utilities. When an electron beam is used as a heating source by focussing, the electron beam has features of high focusability, high controllability and high energy density, so that the electron beam is used for parts requiring high quality processing from micro machining, case hardening, and welding to melting furnaces of metals of high melting point. Presently is necessary to hold ultra high voltage for acceleration and high vacuum because of lower current. Since the processing capability with high energy density is high and the energy consumption efficiency is also high for the chemical field using the high energy density of the electron beam, the application are researched in the field from sterilization of medical instruments, sterilization of sludge, through food processing, improvement of thermal resistance of insulated wires to flue gas irradiation to desulfurize and denitrify. But a practical use is not yet realized because of small current of electron beam. Therefore, the largest technological problem may be the development of high current electron gun and the beam control systems.

  19. Multi-electron beam system for high resolution electron beam induced deposition

    NARCIS (Netherlands)

    Van Bruggen, M.J.

    2008-01-01

    The development of a multi-electron beam system is described which is dedicated for electron beam induced deposition (EBID) with sub-10 nm resolution. EBID is a promising mask-less nanolithography technique which has the potential to become a viable technique for the fabrication of 20-2 nm

  20. A simple electron-beam lithography system

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Madsen, Dorte Nørgaard; Bøggild, Peter

    2005-01-01

    A large number of applications of electron-beam lithography (EBL) systems in nanotechnology have been demonstrated in recent years. In this paper we present a simple and general-purpose EBL system constructed by insertion of an electrostatic deflector plate system at the electron-beam exit...... of the column of a scanning electron microscope (SEM). The system can easily be mounted on most standard SEM systems. The tested setup allows an area of up to about 50 x 50 pm to be scanned, if the upper limit for acceptable reduction of the SEM resolution is set to 10 run. We demonstrate how the EBL system can...... be used to write three-dimensional nanostructures by electron-beam deposition. (C) 2004 Elsevier B.V. All rights reserved....

  1. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Science.gov (United States)

    Lucero, J. F.; Rojas, J. I.

    2016-07-01

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient's entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  2. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt [Universidad Nacional de Costa Rica, Heredia (Costa Rica); Hope International, Guatemala (Guatemala); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XXI, San José (Costa Rica)

    2016-07-07

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  3. Effects of electron beam irradiation on cut flowers and mites

    Energy Technology Data Exchange (ETDEWEB)

    Dohino, Toshiyuki; Tanabe, Kazuo [Yokohama Plant Protection Station (Japan)

    1994-08-01

    Two spotted spider mite, Tetranychus urticae KOCH were irradiated with electron beams (2.5MeV) to develop an alternative quarantine treatment for imported cut flowers. The tolerance of eggs increased with age (1-5-day-old). Immature stages (larva-teleiochrysalis) irradiated at 0.4-0.8kGy increased tolerance with their development. Mated mature females irradiated at 0.4kGy or higher did not produce viable eggs, although temporary recovery was observed at 0.2kGy. Adult males were sterilized at 0.4kGy because non-irradiated virgin females mated with yielded female progeny malformed and sterilized. Various effects of electron beam irradiation were observed when nine species of cut flowers were irradiated in 5MeV Dynamitron accelerator. Chrysanthemum and rose were most sensitive among cut flowers. (author).

  4. The use of electron beams for pasteurization of meats

    Energy Technology Data Exchange (ETDEWEB)

    Prestwich, K.R.; Kaye, R.J.; Turman, B.N.; Neau, E.L.

    1994-12-01

    Electron beam accelerators can be used for electronic pasteurization of meat products by: (1) using the electrons directly impacting the products, or (2) optimizing the conversion of electron energy to x-rays and treating the product with these x-rays. The choice of process depends on the configuration of the product when it is treated. For electron treatment, ten million electron volt (MeV) kinetic energy is the maximum allowed by international agreement. The depth of penetration of electrons with that energy into a product with density of meat is about five centimeters (cm). Two-sided treatment can be done on products up to 10 cm thick with a two-to-one ratio between minimum and maximum dose. Ground beef patties are about 1.25 cm (0.5 inch thick). Beams with 2.5 MeV electron energy could be used to treat these products. Our calculations show that maximum to minimum dose ratios less than 1.2 can be achieved with this energy if the transverse beam energy is small. If the product thickness is greater than 10 cm, x-rays can provide the needed dose uniformity. Uniform doses can be supplied for pallets with dimensions greater than 1.2 m on each side using x-rays from a 5 MeV electron beam. The efficiency of converting the electron beam to x-rays and configurations to achieve dose uniformity are discussed.

  5. Electron beam irradiation of Matricaria chamomilla L. for microbial decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Nemtanu, Monica R. [National Institute for Lasers, Plasma and Radiation Physics, Electron Accelerator Laboratory, 409 Atomistilor Street, P.O. Box MG-36, 077125 Bucharest-Magurele (Romania)], E-mail: monica.nemtanu@inflpr.ro; Kikuchi, Irene Satiko; Jesus Andreoli Pinto, Terezinha de [University of Sao Paulo, Faculty of Pharmaceutical Sciences, Department of Pharmacy, Av. Prof. Lineu Prestes, 580-Bloco 13, Cidade Universitaria, 05508-900 Sao Paulo (Brazil); Mazilu, Elena; Setnic, Silvia [S.C. Hofigal Export-Import S.A., 2A Intrarea Serelor Street, 75669, Bucharest 4 (Romania); Bucur, Marcela [University of Bucharest, Faculty of Biology, Department of Microbiology, 1-3 Aleea Portocalelor Street, Bucharest 6 (Romania); Duliu, Octavian G. [University of Bucharest, Department of Atomic and Nuclear Physics, P.O. Box MG-11, 077125 Bucharest (Romania); Meltzer, Viorica; Pincu, Elena [University of Bucharest, Faculty of Chemistry, Department of Physical Chemistry, Bd. Regina Elisabeta 4-12, 030018 Bucharest (Romania)

    2008-05-15

    Wild chamomile (Matricaria chamomilla L.) is one of the most popular herbal materials with both internal and external use to cure different health disturbances. As a consequence of its origin, chamomile could carry various microbial contaminants which offer different hazards to the final consumer. Reduction of the microbial load to the in force regulation limits represents an important phase in the technological process of vegetal materials, and the electron beam treatment might be an efficient alternative to the classical methods of hygienic quality assurance. The purpose of the study was to analyze the potential application of the electron beam treatment in order to assure the microbial safety of the wild chamomile. Samples of chamomile dry inflorescences were treated in electron beam (e-beam) of 6 MeV mean energy, at room temperature and ambient pressure. Some loss of the chemical compounds with bioactive role could be noticed, but the number of microorganisms decreased as a function on the absorbed dose. Consequently, the microbial quality of studied vegetal material inflorescences was improved by e-beam irradiation.

  6. Activity of antibodies against Salmonella dublin, Toxoplasma gondii, or Actinobacillus pleuropneumoniae in sera after treatment with electron beam irradiation or binary ethylenimine

    DEFF Research Database (Denmark)

    Kyvsgaard, N.C.; Lind, Peter; Preuss, T.

    1996-01-01

    beam irradiation or binary ethylenimine (BEI) treatment The treatments were performed with sera obtained from pigs or cattle. For each treatment level, the posttreatment activity was plotted against the pretreatment activity and regression analyses were carried out. The slope of the regression line......Viral contamination of biological material may constitute a risk when samples are exchanged between countries, and it may be necessary to subject the material to an inactivation treatment. The present study investigated possible adverse effects on antibody activity subsequent to either electron...... was used as an estimate for the relative posttreatment activity. For a Toxoplasma gondii indirect enzyme-linked immunosorbent assay (ELISA) and agglutination assay as well as for a Salmonella dublin indirect ELISA, the posttreatment activity was more than 89% of the pretreatment activity when the samples...

  7. In-air fluence profiles and water depth dose for uncollimated electron beams

    Science.gov (United States)

    Toutaoui, Abedelkadar; Aichouche, Amar Nassim; Adjidir, Kenza Adjidir; Chami, Ahmed Chafik

    2008-01-01

    Advanced electron beam dose calculation models for radiation treatment planning systems require the input of a phase space beam model to configure a clinical electron beam in a computer. This beam model is a distribution in position, energy, and direction of electrons and photons in a plane in front of the patient. The phase space beam model can be determined by Monte Carlo simulation of the treatment head or from a limited set of measurements. In the latter case, parameters of the electron phase space beam model are obtained by fitting measured to calculated dosimetric data. In the present work, data for air fluence profiles and water depth doses have been presented for electron beams without an applicator for a medical linear accelerator. These data are used to parameterize the electron phase space beam model to a Monte Carlo dose calculation module available in the first commercial (MDS Nordion, now Nucletron) Monte Carlo treatment planning for electron beams. PMID:19893707

  8. Electron Beam Lithography for nano-patterning

    DEFF Research Database (Denmark)

    Greibe, Tine; Anhøj, Thomas Aarøe; Khomtchenko, Elena

    2014-01-01

    Electron beam lithography is a versatile tool for fabrication of nano-sized patterns. The patterns are generated by scanning a focused beam of high-energy electrons onto a substrate coated with a thin layer of electron-sensitive polymer (resist), i.e. by directly writing custom-made patterns...... in a polymer. Electron beam lithography is a suitable method for nano-sized production, research, or development of semiconductor components on a low-volume level. Here, we present electron beam lithography available at DTU Danchip. We expertize a JEOL 9500FZ with electrons accelerated to an energy of 100ke......V and focused to a beam spot size down to ~5nm. The electron beam can scan across the substrate with a speed of 100MHz and can write areas of 1mm x 1mm without stitching. In order to ensure high-precision patterning, the beam position on the substrate is controlled by a two-stage deflector system and substrates...

  9. Improved electron-beam welding technique

    Science.gov (United States)

    Schumacher, B.

    1970-01-01

    Electron-beam generator produces high quality welds without vaporization by relying on the mobility and hydrodynamic properties of the material in its liquid phase. The power density of the beam is relative to the speed of the workpiece, producing an inclined weld-front.

  10. Electron beam relaxation in turbulent plasma

    Energy Technology Data Exchange (ETDEWEB)

    Karfidov, D.M.; Lukina, N.A. [General Physics Institute of Russian Academy of Sciences, Moscow (Russian Federation)

    1997-12-31

    The electron beam interaction with collisionless plasma was studied experimentally. The beam relaxation length is shown to be determined by strong Langmuir turbulence development. Effective collision frequency of turbulence is determined; final cavity size determined from plasma electrical field strength measurements is estimated to be about 30 Debay lengths. (author)

  11. The effects of electron beam rotation upon electron beam welded copper-304 couples

    Science.gov (United States)

    Zysk, Kevin Tacy

    The United States Air Force, Arnold Engineering Development Center, has been using copper to 304 stainless steel couples made using the electron beam welding process during the fabrication of intrusive gas-path diagnostic probes for over five years. Only a limited physical analysis of the resulting welds had been done. The purpose of this investigation was to determine the effects that varying the rotation frequency of the electron beam had upon the mechanical characteristics of the copper to 304 stainless steel couples. All controllable weld process parameters were held constant with the exception of the electron beam rotation frequency; the rotation frequency was varied from 20 Hz to 180 Hz in steps of 20 Hz. Samples welded without electron beam rotation provided a baseline for comparison. Microhardness distributions showed that weld region homogeneity as evidenced by microhardness maps and optical microscopy was a function of the electron beam rotation frequency. There was no correlation between electron beam rotation frequency and weld tensile strength since each test coupon failed in the Cu base material outside of the weld region. The welds made at all electron beam rotation frequencies used for this study contained cracks within the weld region, heat affected zone (HAZ), or both. The relative number, length, and location of the individual cracks changed with electron beam rotation frequency. Cracking in the HAZ due to liquid metal embrittlement (LME) was not evident in those samples welded with the electron beam rotation frequencies below 100 Hz, Cracking due to LME outside of the weld region in the HAZ was observed to increase with the electron beam rotation frequency above 80 Hz. The relationship between weld region cracking and residual stress within the weld region was shown to be dependent on the electron beam rotation frequency. Cracking in the weld region was not observed in samples welded with the electron beam rotation frequency above 80 Hz

  12. Study on the effect of post weld heat treatment parameters on the relaxation of welding residual stresses in electron beam welded P91 steel plates

    OpenAIRE

    Venkata, K. Abburi; Kumar, S.; Dey, H.C.; Smith, D. J.; Bouchard, P J; Truman, C.E

    2014-01-01

    Residual stresses are created by localised heating effects that occur during the welding process. Post weld heat treatment (PWHT) is the most convenient method for stress relief of welds. But PWHT cannot completely eliminate the residual stresses. So, it is essential to determine the influence of PWHT parameters like holding temperature and time on the stress relaxation for optimising the process. The selected material is modified 9Cr-1Mo (Grade 91) steel in the form of plates welded together...

  13. Effect of post-weld heat treatment on microstructure, hardness and low-temperature impact toughness of electron beam welds of NIFS-HEAT-2 and CEA-J57 heats of V–4Ti–4Cr alloy

    Directory of Open Access Journals (Sweden)

    V. Tsisar

    2016-12-01

    Full Text Available Bead-on-plate electron beam welding in high vacuum atmosphere was applied to the plates of NIFS-HEAT-2 and CEA-J57 heats of V–4Ti–4Cr alloy. Effect of post-weld heat treatment (PWHT in the temperature range 673–1273K on the hardness, impact toughness at 77K and microstructure of weld metal was investigated. After PWHT at 773K, hardness of weld metal slightly decreases from 180HV100 (as-welded state to ∼170HV100 while absorbed energy increases up to ∼10J showing ductile fracture mode. PWHT at 973K results in re-hardening of weld metal up to ∼180HV100 caused by re-precipitation of Ti–C,O,N precipitates and corresponding decreasing absorbed energy to ∼2J with brittle fracture mode. PWHT in-between 1073–1273K results in gradual recovery of hardness towards values comparable with those of base metal. Impact toughness (77 K of weld metal after PWHT at 1073K is not recovered nether to the value in as-welded state nor to that one of base metal.

  14. Electron beam focusing in the magnetic field of a bent electron beam evaporator

    Directory of Open Access Journals (Sweden)

    M Salahshoor

    2017-08-01

    Full Text Available In this paper, the vacuum film deposition through electron beam evaporation has been reviewed and the effect of magnetic field on the operation of this system has been explained. Then, the magnetic field distribution due to magnetic components configuartion of a commercial evaporation source with 270-degree electron beam gun (manufactured by Sharif University Branch of ACECR, has been simulated by means of a finite element software, ANSYS. The simulation result was verified by comparing with the results obtained from measurement by Hall Effect sensor. Furthermore, by using the ray-tracing capability of the software, the capability of the magnetic lens of this device for electron beam focusing has been investigated. The predicted position of the electron beam spot on the target is in good agreement with experimental observations  

  15. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose.

    Science.gov (United States)

    Salem, Ahmed; Mohamad, Issa; Dayyat, Abdulmajeed; Kanaa'n, Haitham; Sarhan, Nasim; Roujob, Ibrahim; Salem, Abdel-Fattah; Afifi, Shatha; Jaradat, Imad; Mubiden, Rasmi; Almousa, Abdelateif

    2015-01-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dose and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V(20 Gy)), heart volume percentage receiving at least 25 Gy (V(25 Gy)). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p photon-electron (mean = 50.8 ± 40.9 cm(3)) and photon-only beams (mean = 32.2 ± 28.1 cm(3), p = 0.114). Heart V(25 Gy) was not statistically different among the plans (p = 0.999). Total lung V(20 Gy) was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p photon-only plans demonstrated the highest target coverage and total lung V(20 Gy). The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the

  16. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose

    Energy Technology Data Exchange (ETDEWEB)

    Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Mohamad, Issa; Dayyat, Abdulmajeed [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Kanaa’n, Haitham [Section of Medical Physics, Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Sarhan, Nasim [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Roujob, Ibrahim [Section of Medical Physics, Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Salem, Abdel-Fattah [Department of Obstetrics and Gynecology, Hashemite University, Zarqa (Jordan); Afifi, Shatha [Section of Medical Physics, Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Jaradat, Imad; Mubiden, Rasmi; Almousa, Abdelateif [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan)

    2015-10-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dose and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon

  17. System of video observation for electron beam welding process

    Science.gov (United States)

    Laptenok, V. D.; Seregin, Y. N.; Bocharov, A. N.; Murygin, A. V.; Tynchenko, V. S.

    2016-04-01

    Equipment of video observation system for electron beam welding process was developed. Construction of video observation system allows to reduce negative effects on video camera during the process of electron beam welding and get qualitative images of this process.

  18. Study on local vacuum electron beam welding of flange rim

    CERN Document Server

    He Cheng Dan; Ying Lei; Xu Qi Jin

    2002-01-01

    Local vacuum electron beam welding and its application prospect in military and civil industry are introduced. A home made local vacuum electron beam welding is completed. Its main technical parameters and key techniques are also presented

  19. Coulomb-Driven Relativistic Electron Beam Compression

    Science.gov (United States)

    Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhao, Lingrong; Zhu, Pengfei; Xiang, Dao; Zhang, Jie

    2018-01-01

    Coulomb interaction between charged particles is a well-known phenomenon in many areas of research. In general, the Coulomb repulsion force broadens the pulse width of an electron bunch and limits the temporal resolution of many scientific facilities such as ultrafast electron diffraction and x-ray free-electron lasers. Here we demonstrate a scheme that actually makes use of the Coulomb force to compress a relativistic electron beam. Furthermore, we show that the Coulomb-driven bunch compression process does not introduce additional timing jitter, which is in sharp contrast to the conventional radio-frequency buncher technique. Our work not only leads to enhanced temporal resolution in electron-beam-based ultrafast instruments that may provide new opportunities in probing material systems far from equilibrium, but also opens a promising direction for advanced beam manipulation through self-field interactions.

  20. Electron Beam Source for Technological Applications

    Science.gov (United States)

    Polyakov, V. A.; Shchedrin, I. S.

    1997-05-01

    Electron beam source with thermionic cathode and its application for technological purposes are described.Three electrode electron gun has a lanthanum hexaboride disc emitter with indirect heating. Accelerating voltage can be varied from 20 to 100 kV.Maximum d.c. current is 1-2 A for emitter diameter 4-5 mm.Magnetic focusing lens of solenoidal type ensures high beam power density on the object processed - up to 10 MW per sq.sm.This electron source was used for welding and thermoprocessing - surface hardening of ball-bearings. To ensure required complex power distribution on their surface special electronic unit for electron beam position control was designed.At the surface of ball-bearings the layer with hardness of 62-64 HRC and thickness about 1-1.5 mm was formed after electron processing that considerably increased their working period.

  1. Modification of Biodegradable Polyesters Using Electron Beam

    OpenAIRE

    M. Suhartini

    2013-01-01

    Poly(4-Hydroxybutirat) P4HB, Poly(butylene succinate-co-adipate) PBSA and Poly(-caprolactone) PCL were electron beam (EB)-irradiated. Poly(4-Hydroxybutirat) was irradiated without any polyfunctional monomers (PFM). While PBSA and PCL were irradiated in the presence of polyfunctional monomers such as Trimethallyl isocyanurate (TMAIC), Polyethyleneglycol dimethacrylate (2G, 4G), Trimethylolpropane trimethacrylate (TMPT) and Tetramethylolmethane tetraacrylate (A-TMMT) at ambient temperature. Ai...

  2. Modification of Biodegradable Polyesters Using Electron Beam

    OpenAIRE

    M. Suhartini

    2013-01-01

    Poly(4-Hydroxybutirat)p4hb, Poly(butylene succinate-co-adipate) PBSA and Poly(e-caprolactone) PCL were electron beam (EB)-irradiated. Poly(4-Hydroxybutirat) was irradiated without any polyfunctional monomers (PFM). While PBSA and PCL were irradiated in the presence of polyfunctional monomers such asTrimethallyl isocyanurate (TMAIC), Polyethyleneglycol dimethacrylate (2G, 4G), Trimethylolpropane trimethacrylate (TMPT) and Tetramethylolmethane tetraacrylate (A-TMMT) at ambient temperature. Ai...

  3. Preventing Contamination In Electron-Beam Welds

    Science.gov (United States)

    Goodin, Wesley D.; Gulbrandsen, Kevin A.; Oleksiak, Carl

    1990-01-01

    Simple expedient eliminates time-consuming, expensive manual hand grinding. Use of groove and backup tube greatly reduces postweld cleanup in some electron-beam welding operations. Tube-backup method developed for titanium parts, configurations of which prevents use of solid-block backup. In new welding configuration, tube inserted in groove to prevent contact between alumina beads and molten weld root. When welding complete and beads and tube removed, only minor spatter remains and is ground away easily.

  4. Electron beam position monitor for a dielectric microaccelerator.

    Science.gov (United States)

    Soong, Ken; Peralta, Edgar A; England, R Joel; Wu, Ziran; Colby, Eric R; Makasyuk, Igor; MacArthur, James P; Ceballos, Andrew; Byer, Robert L

    2014-08-15

    We report the fabrication and first demonstration of an electron beam position monitor for a dielectric microaccelerator. This device is fabricated on a fused silica substrate using standard optical lithography techniques and uses the radiated optical wavelength to measure the electron beam position with a resolution of 10 μm, or 7% of the electron beam spot size. This device also measures the electron beam spot size in one dimension.

  5. Gamma Putty dosimetric studies in electron beam

    Directory of Open Access Journals (Sweden)

    Aime M Gloi

    2016-01-01

    Full Text Available Traditionally, lead has been used for field shaping in megavoltage electron beams in radiation therapy. In this study, we analyze the dosimetric parameters of a nontoxic, high atomic number (Z = 83, bismuth-loaded material called Gamma Putty that is malleable and can be easily molded to any desired shape. First, we placed an ionization chamber at different depths in a solid water phantom under a Gamma Putty shield of thickness (t = 0, 3, 5, 10, 15, 20, and 25 mm, respectively and measured the ionizing radiation on the central axis (CAX for electron beam ranging in energies from 6 to 20 MeV. Next, we investigated the relationship between the relative ionization (RI measured at a fixed depth for several Gamma Putty shield at different cutout diameters ranging from 2 to 5 cm for various beam energies and derived an exponential fitting equation for clinical purposes. The dose profiles along the CAX show that bremsstrahlung dominates for Gamma Putty thickness >15 mm. For high-energy beams (12-20 MeV and all Gamma Putty thicknesses up to 25 mm, RI below 5% could not be achieved due to the strong bremsstrahlung component. However, Gamma Putty is a very suitable material for reducing the transmission factor below 5% and protecting underlying normal tissues for low-energy electron beams (6-9 MeV.

  6. Process variation in electron beam sterilization

    Science.gov (United States)

    Beck, Jeffrey A.

    2012-08-01

    The qualification and control of electron beam sterilization can be improved by the application of proven statistical analysis techniques such as Analysis of Variance (ANOVA) and Statistical Tolerance Limits. These statistical techniques can be useful tools in: Locating and quantifying the minimum and maximum absorbed dose in a product. Estimating the expected process maximum dose, given a minimum sterilizing dose. Setting a process minimum dose target, based on an allowance for random measurement and process variation. Determining the dose relationship between a reference dosimeter and process minimum and maximum doses. This study investigates and demonstrates the application of these tools in qualifying electron beam sterilization, and compares the conclusions obtained with those obtained using practices recommended in Association for the Advancement of Medical Instrumentation (AAMI) TIR 29 (2002) Guide for Process Control in Radiation Sterilization. The study supports the following conclusions for electron beam processes: ANOVA is a more effective tool for evaluating the equivalency of absorbed doses than methods suggested in AAMI TIR29 (2002). Process limits computed using statistical tolerance limits more accurately reflect actual process variability than the AAMI method, which applies +/-2 sample standard deviations (s) regardless of sample size. The use of reference dose ratios lends itself to qualification using statistical tolerance limits. The current AAMI recommended approach may result in an overly optimistic estimate of the reference dose adjustment factor, as it is based on application of +/-2(s) tolerances regardless of sample size.

  7. Effects of electron beam irradiation on tin dioxide gas sensors

    Indian Academy of Sciences (India)

    WINTEC

    Abstract. In this paper, the effects of electron beam irradiation on the gas sensing performance of tin dioxide thin films toward H2 are studied. The tin dioxide thin films were prepared by ultrasonic spray pyrolysis. The results show that the sensitivity increased after electron beam irradiation. The electron beam irradiation.

  8. Electron Beam Welding of Gear Wheels by Splitted Beam

    Directory of Open Access Journals (Sweden)

    Dřímal Daniel

    2014-06-01

    Full Text Available This contribution deals with the issue of electron beam welding of high-accurate gear wheels composed of a spur gearing and fluted shaft joined with a face weld for automotive industry. Both parts made of the high-strength low-alloy steel are welded in the condition after final machining and heat treatment, performed by case hardening, whereas it is required that the run-out in the critical point of weldment after welding, i. e. after the final operation, would be 0.04 mm max..

  9. Statistical process control for electron beam monitoring.

    Science.gov (United States)

    López-Tarjuelo, Juan; Luquero-Llopis, Naika; García-Mollá, Rafael; Quirós-Higueras, Juan David; Bouché-Babiloni, Ana; Juan-Senabre, Xavier Jordi; de Marco-Blancas, Noelia; Ferrer-Albiach, Carlos; Santos-Serra, Agustín

    2015-07-01

    To assess the electron beam monitoring statistical process control (SPC) in linear accelerator (linac) daily quality control. We present a long-term record of our measurements and evaluate which SPC-led conditions are feasible for maintaining control. We retrieved our linac beam calibration, symmetry, and flatness daily records for all electron beam energies from January 2008 to December 2013, and retrospectively studied how SPC could have been applied and which of its features could be used in the future. A set of adjustment interventions designed to maintain these parameters under control was also simulated. All phase I data was under control. The dose plots were characterized by rising trends followed by steep drops caused by our attempts to re-center the linac beam calibration. Where flatness and symmetry trends were detected they were less-well defined. The process capability ratios ranged from 1.6 to 9.3 at a 2% specification level. Simulated interventions ranged from 2% to 34% of the total number of measurement sessions. We also noted that if prospective SPC had been applied it would have met quality control specifications. SPC can be used to assess the inherent variability of our electron beam monitoring system. It can also indicate whether a process is capable of maintaining electron parameters under control with respect to established specifications by using a daily checking device, but this is not practical unless a method to establish direct feedback from the device to the linac can be devised. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    Energy Technology Data Exchange (ETDEWEB)

    Yasumoto, Kyoden; Fujino, Masayuki; Supriyadi (Kyoto Univ., Uji (Japan). Research Inst. for Food Science); Suzuki, Tetsuya; Hayashi, Toru

    1991-08-01

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 10{sup 8}/g. Turmeric finger which was irradiated by electron beam at 10 kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10 kGy and 20 kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers. (author).

  11. Electron Beam Propagation in a Plasma

    Directory of Open Access Journals (Sweden)

    Kyoung W. Min

    1988-06-01

    Full Text Available Electron beam propagation in a fully ionized plasma has been studied using a one-dimensional particle simulation model. We compare the results of electrostatic simulations to those of electromagnetic simulations. The electrostatic results show the essential features of beam-plasma instability which accelerates ambient plasmas. The results also show the heating of ambient plasmas and the trapping of plasmas due to the locally generated electric field. The level of the radiation generated by the same non-relativistic beam is slightly higher than the noise level. We discuss the results in context of the heating of coronal plasma during solar flares.

  12. Hybrid optical: electron-beam resists

    Science.gov (United States)

    Lennon, D. M.; Spector, S. J.; Fedynyshyn, T. H.; Lyszczarz, T. M.; Rothschild, M.; Thackeray, J.; Spear-Alfonso, K.

    2007-03-01

    Combining optical and electron beam exposures on the same wafer level is an attractive approach for extending the usefulness of current generation optical tools. This technique requires high-performance hybrid resists that perform equally well with optical and e-beam tools. In this paper Rohm and Haas EPIC TM 2340, a 193-nm chemically amplified photoresist, is used in a hybrid exposure role. The e-beam tool was used to pattern 45 nm half-pitch features and a 193- nm immersion stepper was used to pattern 60-nm half-pitch features in the same resist layer. The effects of processing parameters and delay times were investigated.

  13. Foil focusing of relativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Jr., Carl August [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-26

    When an intense relativistic electron beams (IREB) passes through a grounded metal foil, the transverse electric field due to the beam space charge is locally shorted out, and the beam is focused by the magnetic field of its current. The effect can be treated as focusing by a thin lens with first order aberration. Expressions for the focal length and aberration coefficient of the equivalent thin lens are developed in this note. These are then applied to practical examples representative of IREB research at Los Alamos National Laboratory.

  14. Susceptor heating device for electron beam brazing

    Science.gov (United States)

    Antieau, Susan M.; Johnson, Robert G. R.

    1999-01-01

    A brazing device and method are provided which locally apply a controlled amount of heat to a selected area, within a vacuum. The device brazes two components together with a brazing metal. A susceptor plate is placed in thermal contact with one of the components. A serrated pedestal supports the susceptor plate. When the pedestal and susceptor plate are in place, an electron gun irradiates an electron beam at the susceptor plate such that the susceptor plate is sufficiently heated to transfer heat through the one component and melt the brazing metal.

  15. An electron beam imaging system for quality assurance in IORT

    Energy Technology Data Exchange (ETDEWEB)

    Casali, F.; Rossi, M.; Morigi, M.P. E-mail: morigi@df.unibo.it; Brancaccio, R.; Paltrinieri, E.; Bettuzzi, M.; Romani, D.; Ciocca, M.; Tosi, G.; Ronsivalle, C.; Vignati, M

    2004-01-01

    Intraoperative radiation therapy is a special radiotherapy technique, which enables a high dose of radiation to be given in a single fraction during oncological surgery. The major stumbling block to the large-scale application of the technique is the transfer of the patient, with an open wound, from the operating room to the radiation therapy bunker, with the consequent organisational problems and the increased risk of infection. To overcome these limitations, in the last few years a new kind of linear accelerator, the Novac 7, conceived for direct use in the surgical room, has become available. Novac 7 can deliver electron beams of different energies (3, 5, 7 and 9 MeV), with a high dose rate (up to 20 Gy/min). The aim of this work, funded by ENEA in the framework of a research contract, is the development of an innovative system for on-line measurements of 2D dose distributions and electron beam characterisation, before radiotherapy treatment with Novac 7. The system is made up of the following components: (a) an electron-light converter; (b) a 14 bit cooled CCD camera; (c) a personal computer with an ad hoc written software for image acquisition and processing. The performances of the prototype have been characterised experimentally with different electron-light converters. Several tests have concerned the assessment of the detector response as a function of impulse number and electron beam energy. Finally, the experimental results concerning beam profiles have been compared with data acquired with other dosimetric techniques. The achieved results make it possible to say that the developed system is suitable for fast quality assurance measurements and verification of 2D dose distributions.

  16. Investigation of the clinical potential of scattering foil free electron beams.

    Science.gov (United States)

    Eldib, Ahmed; Jin, Lihui; Li, Jinsheng; Ma, C-M Charlie

    2014-02-21

    Electron beam therapy has been an important radiation therapy modality for many decades. Studies have been conducted recently for more efficient and advanced delivery of electron beam radiation therapy. X-ray contamination is a common problem that exists with all of the advanced electron beam therapy techniques such as Bolus Electron conformal therapy, segmented electron conformal therapy, and modulated electron arc therapy. X-ray contamination could add some limitations to the advancement and clinical utility of those electron modalities. It was previously shown in the literature that the scattering foil is one of the major accelerator parts contributing to the generation of bremsstrahlung photons. Thus, in this work we investigate the dosimetric characteristics of scattering foil free (SFF) electron beams and the feasibility of using those beams for breast cancer boosts. The SFF electron beams were modeled and simulated using the Monte Carlo method. CT scans of six previously treated breast patients were used for the treatment plan generation utilizing our in-house Monte Carlo-based treatment planning system. Electron boost plans with conventional beams and the SFF beams were generated, respectively, for all patients. A significant reduction of the photon component was observed with the removal of the primary scattering foil for beam energies higher than 12 MeV. Flatness was greatly affected but the difference in flatness between conventional and SFF beams was much reduced for small cone sizes, which were often used clinically for breast boosts. It was found that the SFF electron beams could deliver high-quality dose distributions as conventional electron beams for boost treatments of the breast with an added advantage of a further reduced dose to the lung and the heart.

  17. Contact lens surface by electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung Hyuck [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin [Dongshin Univ., Naju (Korea, Republic of)

    2011-07-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility.

  18. Electron beams in research and technology

    Science.gov (United States)

    Mehnert, R.

    1995-11-01

    Fast electrons lose their energy by inelastic collisions with electrons of target molecules forming secondary electrons and excited molecules. Coulomb interaction of secondary electrons with valence electrons of neighboring molecules leads to the formation of radical cations, thermalized electrons, excited molecular states and radicals. The primary reactive species initiate chemical reactions in the materials irradiated. Polymer modifications using accelerated electrons such as cross-linking of cable insulation, tubes, pipes and moldings, vulcanization of elastomers, grafting of polymer surfaces, processing of foamed plastics and heat shrinkable materials have gained wide industrial acceptance. A steadily growing electron beam technology is curing of paints, lacquers, printing inks and functional coatings. Electron beam processing offers high productivity, the possibility to treat the materials at normal temperature and pressure, excellent process control and clean production conditions. On an industrial scale the most important application of fast electrons is curing of 100% reactive monomer/prepolymer systems. Mainly acrylates and epoxides are used to formulate functional coatings on substrates such as paper, foil, wood, fibre board and high pressure laminates. A survey is given about the reaction mechanism of curing, the characterization of cured coatings, and of some industrial application.

  19. Electron beam damage in high temperature polymers

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S. (Dayton Univ., OH (USA). Research Inst.); Adams, W.W. (Air Force Materials Lab., Wright-Patterson AFB, OH (USA))

    1990-01-01

    Electron microscopic studies of polymers are limited due to beam damage. Two concerns are the damage mechanism in a particular material, and the maximum dose for a material before damage effects are observed. From the knowledge of the dose required for damage to the polymer structure, optimum parameters for electron microscopy imaging can be determined. In the present study, electron beam damage of polymers has been quantified by monitoring changes in the diffraction intensity as a function of electron dose. The beam damage characteristics of the following polymers were studied: poly(p-phenylene benzobisthiazole) (PBZT); poly(p-phenylene benzobisoxazole) (PBO); poly(benzoxazole) (ABPBO); poly(benzimidazole) (ABPBI); poly(p-phenylene terephthalamide) (PPTA); and poly(aryl ether ether ketone) (PEEK). Previously published literature results on polyethylene (PE), polyoxymethylene (POM), nylon-6, poly(ethylene oxide) (PEO), PBZT, PPTA, PPX, iPS, poly(butylene terephthalate) (PBT), and poly(phenylene sulphide) (PPS) were reviewed. This study demonstrates the strong dependence of the electron beam resistivity of a polymer on its thermal stability/melt temperature. (author).

  20. An Electron Beam Profile Instrument Based on FBGs

    Directory of Open Access Journals (Sweden)

    Dan Sporea

    2014-08-01

    Full Text Available Along with the dose rate and the total irradiation dose measurements, the knowledge of the beam localization and the beam profile/energy distribution in the beam are parameters of interest for charged particle accelerator installations when they are used in scientific investigations, industrial applications or medical treatments. The transverse profile of the beam, its position, its centroid location, and its focus or flatness depend on the instrument operating conditions or on the beam exit setup. Proof-of-concept of a new type of charged particle beam diagnostics based on fiber Bragg gratings (FBGs was demonstrated. Its operating principle relies on the measurement of the peak wavelength changes for an array of FBG sensors as function of the temperature following the exposure to an electron beam. Periodically, the sensor irradiation is stopped and the FBG are force cooled to a reference temperature with which the temperature influencing each sensor during beam exposure is compared. Commercially available FBGs, and FBGs written in radiation resistant optical fibers, were tested under electron beam irradiation in order to study their possible use in this application.

  1. The experimental study of neutralized electron beams for electron cooling

    CERN Document Server

    Bosser, Jacques; MacCaferri, R; Molinari, G; Tranquille, G; Varenne, F; Korotaev, Yu V; Meshkov, I N; Polyakov, V A; Smirnov, A; Syresin, E M

    1996-01-01

    In this report we present the latest experimental results on electron beam neutralization. These experiments have been made at LEAR and on the JINR test bench. The main difficulty in obtaining neutralized beams resides in an instability which is dependent on the electron beam current. A number of methods have been developed in order to overcome this instability and have enabled us to further investigate the possibility of generating intense low energy electron beams for the cooling of Pb ions.

  2. Electron beam throughput from raster to imaging

    Science.gov (United States)

    Zywno, Marek

    2016-12-01

    Two architectures of electron beam tools are presented: single beam MEBES Exara designed and built by Etec Systems for mask writing, and the Reflected E-Beam Lithography tool (REBL), designed and built by KLA-Tencor under a DARPA Agreement No. HR0011-07-9-0007. Both tools have implemented technologies not used before to achieve their goals. The MEBES X, renamed Exara for marketing purposes, used an air bearing stage running in vacuum to achieve smooth continuous scanning. The REBL used 2 dimensional imaging to distribute charge to a 4k pixel swath to achieve writing times on the order of 1 wafer per hour, scalable to throughput approaching optical projection tools. Three stage architectures were designed for continuous scanning of wafers: linear maglev, rotary maglev, and dual linear maglev.

  3. High Efficiency Transverse D. C. Electron Beams.

    Science.gov (United States)

    1984-10-01

    current for Ing a diffraction grating of 280 groves per millimeter. This each enra sl teruin :s indicated onl the left oif the figure prov ided at...moaio niII.i ineacflint MeTw:iI 6003 I(- I1IJL3limmm I i-i Ii t ciM~ pdl )oi’l ii)iioikiixc)1 pWIIpn;jOB. ,)r CyllteC’rIcI 0IIIW 1lllrieCl;ie ll)CIINlyILC...yield ly shown in Fig. 2 where the electron-beam-created plasma is cathode materials had weak spectra. The first five materials visible. The cathode face

  4. Current-limited electron beam injection

    Science.gov (United States)

    Stenzel, R. L.

    1977-01-01

    The injection of an electron beam into a weakly collisional, magnetized background plasma was investigated experimentally. The injected beam was energetic and cold, the background plasma was initially isothermal. Beam and plasma dimensions were so large that the system was considered unbounded. The temporal and spatial evolution of the beam-plasma system was dominated by collective effects. High-frequency electrostatic instabilities rapidly thermalized the beam and heated the background electrons. The injected beam current was balanced by a return current consisting of background electrons drifting toward the beam source. The drift between electrons and ions gave rise to an ion acoustic instability which developed into strong three-dimensional turbulence. It was shown that the injected beam current was limited by the return current which is approximately given by the electron saturation current. Non-Maxwellian electron distribution functions were observed.

  5. Electron beam analysis of particulate cometary material

    Science.gov (United States)

    Bradley, John

    1989-01-01

    Electron microscopy will be useful for characterization of inorganic dust grains in returned comet nucleus samples. The choice of instrument(s) will depend primarily on the nature of the samples, but ultimately a variety of electron-beam methods could be employed. Scanning and analytical (transmission) electron microscopy are the logical choise for morphological, mineralogical, and bulk chemical analyses of dust grains removed from ices. It may also be possible to examine unmelted ice/dust mixtures using an environmental scanning electron microscope equipped with a cryo-transfer unit and a cold stage. Electron microscopic observations of comet nuclei might include: (1) porosities of dust grains; (2) morphologies and microstructures of individual mineral grains; (3) relative abundances of olivine, pyroxene, and glass; and (4) the presence of phases that might have resulted from aqueous alteration (layer silicates, carbonates, sulfates).

  6. Radiative cooling of relativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhirong [Stanford Univ., CA (United States)

    1998-05-01

    Modern high-energy particle accelerators and synchrotron light sources demand smaller and smaller beam emittances in order to achieve higher luminosity or better brightness. For light particles such as electrons and positrons, radiation damping is a natural and effective way to obtain low emittance beams. However, the quantum aspect of radiation introduces random noise into the damped beams, yielding equilibrium emittances which depend upon the design of a specific machine. In this dissertation, the author attempts to make a complete analysis of the process of radiation damping and quantum excitation in various accelerator systems, such as bending magnets, focusing channels and laser fields. Because radiation is formed over a finite time and emitted in quanta of discrete energies, he invokes the quantum mechanical approach whenever the quasiclassical picture of radiation is insufficient. He shows that radiation damping in a focusing system is fundamentally different from that in a bending system. Quantum excitation to the transverse dimensions is absent in a straight, continuous focusing channel, and is exponentially suppressed in a focusing-dominated ring. Thus, the transverse normalized emittances in such systems can in principle be damped to the Compton wavelength of the electron, limited only by the Heisenberg uncertainty principle. In addition, he investigates methods of rapid damping such as radiative laser cooling. He proposes a laser-electron storage ring (LESR) where the electron beam in a compact storage ring repetitively interacts with an intense laser pulse stored in an optical resonator. The laser-electron interaction gives rise to rapid cooling of electron beams and can be used to overcome the space charge effects encountered in a medium energy circular machine. Applications to the designs of low emittance damping rings and compact x-ray sources are also explored.

  7. Study on electron beam in a low energy plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Muhammad Zubair, E-mail: mzubairkhan-um76@yahoo.com [Plasma Technology Research Center, Department of Physics, Faculty of Science, University Malaya, 50603 Kuala Lumpur, Malaysia and Department of Physics, Federal Urdu University of Arts, Science and Technology, 45320 Islamabad (Pakistan); Ling, Yap Seong; San, Wong Chiow [Plasma Technology Research Center, Department of Physics, Faculty of Science, University Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-03-05

    Electron beam emission was investigated in a low energy plasma focus device (2.2 kJ) using copper hollow anode. Faraday cup was used to estimate the energy of the electron beam. XR100CR X-ray spectrometer was used to explore the impact of the electron beam on the target observed from top-on and side-on position. Experiments were carried out at optimized pressure of argon gas. The impact of electron beam is exceptionally notable with two different approaches using lead target inside hollow anode in our plasma focus device.

  8. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2015-08-11

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  9. First test of BNL electron beam ion source with high current density electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, Alexander, E-mail: pikin@bnl.gov; Alessi, James G., E-mail: pikin@bnl.gov; Beebe, Edward N., E-mail: pikin@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); Shornikov, Andrey; Mertzig, Robert; Wenander, Fredrik; Scrivens, Richard [CERN, CH-1211 Geneva 23 (Switzerland)

    2015-01-09

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, the EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.

  10. Total skin electron beam therapy using an inclinable couch on motorized table and a compensating filter

    Science.gov (United States)

    Fuse, H.; Suzuki, K.; Shida, K.; Mori, Y.; Takahashi, H.; Kobayashi, D.; Seki, M.; Isobe, T.; Okumura, T.; Sakae, T.; Sakurai, H.

    2014-06-01

    Total skin electron beam is a specialized technique that involves irradiating the entire skin from the skin surface to only a few millimetres in depth. In the Stanford technique, the patient is in a standing position and six different directional positions are used during treatment. Our technique uses large electron beams in six directions with an inclinable couch on motorized table and a compensating filter was also used to spread the electron beam and move its intensity peak. Dose uniformity measurements were performed using Gafchromic films which indicated that the surface dose was 2.04 ± 0.05 Gy. This technique can ensure the dose reproducibility because the patient is fixed in place using an inclinable couch on a motorized table.

  11. Changes in mechanical and chemical wood properties by electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Schnabel, Thomas, E-mail: thomas.schnabel@fh-salzburg.ac.at [Salzburg University of Applied Sciences, Department of Forest Products Technology and Wood Constructions, Marktstraße 136a, 5431 Kuchl (Austria); Huber, Hermann [Salzburg University of Applied Sciences, Department of Forest Products Technology and Wood Constructions, Marktstraße 136a, 5431 Kuchl (Austria); Grünewald, Tilman A. [BOKU University of Natural Resources and Life Sciences, Institute of Physics and Materials Science, Peter Jordan Straße 82, 1190 Vienna (Austria); Petutschnigg, Alexander [Salzburg University of Applied Sciences, Department of Forest Products Technology and Wood Constructions, Marktstraße 136a, 5431 Kuchl (Austria); BOKU University of Natural Resources and Life Sciences, Konrad Lorenzstraße 24, 3430 Tulln (Austria)

    2015-03-30

    Highlights: • Changes in wood due to electron beam irradiations (EBI) were evaluated. • Wood components undergo different altering mechanisms due to the irradiation. • Chemical reactions in wood lead to better surface hardness of low irradiated wood. - Abstract: This study deals with the influence of various electron beam irradiation (EBI) dosages on the Brinell hardness of Norway spruce. The results of the hardness measurements and the FT-IR spectroscopic analysis show different effects of the EBI at dosages of 25, 50, 100 and 200 kGy. It was assumed that the lignin and carbohydrates undergo different altering mechanisms due to the EBI treatment. New cleavage products and condensation reactions of lignin and carbohydrates lead to better surface hardness of low irradiated wood samples. These results provide a useful basis for further investigations on the changes in wood chemistry and material properties due to electron beam irradiations.

  12. Low Voltage Electron Beam Processing Final Report CRADA No. TC-645-93-A

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wakalopulos, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-16

    This CRADA project was established to develop a small, inexpensive sealed-tube electron beam processing system having immediate applications in industrial, high speed manufacturing processes, and in the Department of Energy (DOE) waste treatment/cleanup operations. The technical work involved the development and demonstration of a compact, sealed, 50-75 kilovolt (kV) EB generator prototype, including controls and power supply. The specific goals of this project were to develop a low cost vacuum tube capable of shooting an electron beam several inches into the air, and to demonstrate that wide area materials processing is feasible by stacking the tubes to produce continuous beams. During the project, we successfully demonstrated the producibility of a low cost electron beam system and several material processing operations of interest to US industry, DOE and, since September 11, 2001, the Homeland Security.

  13. Practical use of a plastic scintillator for quality assurance of electron beam therapy

    Science.gov (United States)

    Yogo, Katsunori; Tatsuno, Yuya; Tsuneda, Masato; Aono, Yuki; Mochizuki, Daiki; Fujisawa, Yoshiki; Matsushita, Akihiro; Ishigami, Minoru; Ishiyama, Hiromichi; Hayakawa, Kazushige

    2017-06-01

    Quality assurance (QA) of clinical electron beams is essential for performing accurate and safe radiation therapy. However, with advances in radiation therapy, QA has become increasingly labor-intensive and time-consuming. In this paper, we propose a tissue-equivalent plastic scintillator for quick and easy QA of clinical electron beams. The proposed tool comprises a plastic scintillator plate and a charge-coupled device camera that enable the scintillation light by electron beams to be recorded with high sensitivity and high spatial resolution. Further, the Cerenkov image is directly subtracted from the scintillation image to discriminate Cerenkov emissions and accurately measure the dose profiles of electron beams with high spatial resolution. Compared with conventional methods, discrepancies in the depth profile improved from 7% to 2% in the buildup region via subtractive corrections. Further, the output brightness showed good linearity with dose, good reproducibility (deviations below 1%), and dose rate independence (within 0.5%). The depth of 50% dose measured with the tool, an index of electron beam quality, was within  ±0.5 mm of that obtained with an ionization chamber. Lateral brightness profiles agreed with the lateral dose profiles to within 4% and no significant improvement was obtained using Cerenkov corrections. Field size agreed to within 0.5 mm with those obtained with ionization chamber. For clinical QA of electron boost treatment, a disk scintillator that mimics the shape of a patient’s breast is applied. The brightness distribution and dose, calculated using a treatment planning system, was generally acceptable for clinical use, except in limited zones. Overall, the proposed plastic scintillator plate tool efficiently performs QA for electron beam therapy and enables simultaneous verification of output constancy, beam quality, depth, and lateral dose profiles during monthly QAs at lower doses of irradiation (small monitor units, MUs).

  14. Comparison of High Resolution Negative Electron Beam Resists

    DEFF Research Database (Denmark)

    Olsen, Brian Bilenberg; Schøler, Mikkel; Shi, Peixiong

    2006-01-01

    Four high resolution negative electron beam resists are compared: TEBN-1 from Tokuyama Corp. Japan, ma-N 2401XP and mr-L 6000AXP from microresist technology GmbH Germany, and SU-8 2000 series from MicroChem Corp., USA. Narrow linewidth high density patterns are defined by 100 kV electron beam...

  15. NOx reduction by electron beam-produced nitrogen atom injection

    Science.gov (United States)

    Penetrante, Bernardino M.

    2002-01-01

    Deactivated atomic nitrogen generated by an electron beam from a gas stream containing more than 99% N.sub.2 is injected at low temperatures into an engine exhaust to reduce NOx emissions. High NOx reduction efficiency is achieved with compact electron beam devices without use of a catalyst.

  16. Polystyrene as a zwitter resist in electron beam lithography based ...

    Indian Academy of Sciences (India)

    The resist action of polystyrene (w, 2,600,000) towards electroless deposition of gold on Si(100) surface following cross-linking by exposing to a 10 kV electron beam, has been investigated employing a scanning electron microscope equipped with electron beam lithography tool. With a low dose of electrons (21 C/cm2), ...

  17. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    user

    The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of sewage water. In general, sewage water comprises of heterogeneous organic based chemicals as well as pathogens. EB. (electron beam) ...

  18. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of sewage water. In general, sewage water comprises of heterogeneous organic based chemicals as well as pathogens. EB (electron beam) ...

  19. Issues for Bringing Electron Beam Irradiators On-Line

    Energy Technology Data Exchange (ETDEWEB)

    Kaye, R.J.; Turman, B.N.

    1999-04-20

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined.

  20. Modelling of electron beam absorption in complex geometries

    Science.gov (United States)

    Klassen, Alexander; Bauereiß, Andreas; Körner, Carolin

    2014-02-01

    Computational modelling of processes that involve highly energetic electrons like electron beam melting, welding, drilling or electron beam lithography, to name but a few, requires information about the attenuation of the electron beam as it passes through the sample. Depth-dose curves as a function of electron energy, target material as well as local surface obliquity have to be provided in situ during the calculation. The most efficient way to address this issue is by employing mathematical expressions. Therefore, we propose an electron beam model based on a set of semi-empirical equations available from different published literature and on theoretical considerations. Particular stress is thereby put on accuracy and the range of validity of the theoretical approach by comparison with experimental data. Finally, we apply our model to powder-bed based additive manufacturing. The numerical results demonstrate that electron beam absorption and depth of penetration have a strong influence on the quality of the fabricated product.

  1. Cutaneous complication after electron beam therapy in breast cancer

    Directory of Open Access Journals (Sweden)

    M Jalilian

    2005-11-01

    Full Text Available Background: Breast cancer is the most common cancer in women and the second cause of death among them. There are several treatment methods for breast cancer, one of which is radiation therapy. There are two important methods of radiation therapy: tangential field and single oppositional field. Main goal of this study is evaluation of factors that have a role in producing acute side effects such as skin burning in breast cancer patients treated by electron beam,in order to decrease these side effects. Methods: From 1/2003 through 7/2004, 200 consecutive patients were evaluated during 18 months in seid-al-shohad hospital, whose mean age was 49 years old. In this study a questionnaire was used including some questions about personal profile such as patient's name, address, registration number, age and some other factors. All patients who were candidated to enter in this investigation filled out the questionnaire at the end of radiation therapy. The patients were examined and their skin burning grades were evaluated by RTOG scale. Data were analyzed by chi-square test using SPSS 11 software. Results: None of patients showed grades O or 4 of burning. 31.5 % of Patients showed grade 1, 64.5 % showed grade 2, 4 % showed grade 3 of burning. There was statistically significant correlation between posterior axillary field and skin burning and there wasnot any meaning between the other factors. Conclusion: It is necessary to pay more attention to posterior axillary field planning including field size, location, photon energy, depth and dose of treatment. Keywords: breast cancer, electron beam radiation therapy, skin burning

  2. Electron beam irradiation of fluoropolymers containing polyethers

    Science.gov (United States)

    Bucio, E.; Burillo, G.; Tapia, F.; Adem, E.; Cedillo, G.; Cassidy, P. E.

    2009-02-01

    A highly fluorinated monomer, 1,3-bis(1,1,1,3,3,3-hexafluoro-2-pentafluorophenyl methoxy-2-propyl)benzene (12F-FBE) was polymerized with some diphenols by polycondensation and then was electron beam irradiated between 100 and 1000 kGy to determine degradation radiochemistry yield ( Gs) by gel permeation chromatography (GPC). The samples were characterized after irradiation by DSC, FTIR, and nuclear magnetic resonance (NMR). The fluoropolymers show apparent degradation in mechanical properties at 300 kGy, except 12F-FBE polymerized with biphenol and bisphenol A, when they did not show any apparent physical change up to 300 kGy; and continue to be flexible and transparent, with a radiochemical yield scission ( Gs) of 0.75, 0.53, 0.88, and 0.38 for 12F-FBE/SDL aliphatic, 12F-FBE/biphenol, 12F-FBE/bisphenol A, and 12F-FBE/bisphenol O, respectively. The number average molecular weights for three of the polymers decrease upon 1000 kGy irradiation to 10% of their original values; however, the polymer from bisphenol A is much more stable and its Mn decreases to only 24% of original.

  3. Fundamentals of high energy electron beam generation

    Science.gov (United States)

    Turman, B. N.; Mazarakis, M. G.; Neau, E. L.

    High energy electron beam accelerator technology has been developed over the past three decades in response to military and energy-related requirements for weapons simulators, directed-energy weapons, and inertially-confined fusion. These applications required high instantaneous power, large beam energy, high accelerated particle energy, and high current. These accelerators are generally referred to as 'pulsed power' devices, and are typified by accelerating potential of millions of volts (MV), beam current in thousands of amperes (KA), pulse duration of tens to hundreds of nanoseconds, kilojoules of beam energy, and instantaneous power of gigawatts to teffawatts (10(exp 9) to 10(exp 12) watts). Much of the early development work was directed toward single pulse machines, but recent work has extended these pulsed power devices to continuously repetitive applications. These relativistic beams penetrate deeply into materials, with stopping range on the order of a centimeter. Such high instantaneous power deposited in depth offers possibilities for new material fabrication and processing capabilities that can only now be explored. Fundamental techniques of pulse compression, high voltage requirements, beam generation and transport under space-charge-dominated conditions will be discussed in this paper.

  4. Heat shrinkage of electron beam modified EVA

    Energy Technology Data Exchange (ETDEWEB)

    Datta, S.K.; Chaki, T.K.; Bhowmick, A.K. [Indian Institute of Technology, Kharagpur (India). Rubber Technology Center; Tikku, V.K.; Pradhan, N.K. [NICCO Corporation Ltd., (Cable Div.), Calcutta (India)

    1997-10-01

    Heat shrinkage of electron beam modified ethylene vinyl acetate copolymer (EVA) has been investigated over a range of times, temperatures, stretching, irradiation doses and trimethylolpropane trimethacrylate (TMPTMA) levels. The irradiated (radiation dose 50 kGy and TMPTMA level 1%) and stretched (100% elongation) sample shrinks to a maximum level when kept at 453K temperature for 60 s. The heat shrinkage of samples irradiated with radiation doses of 20, 50, 100 and 150 kGy increases sharply with increasing stretching in the initial stage. Amnesia rating decreases with increasing radiation dose and TMPTMA level as well as gel content. The high radiation dose and TMPTMA level lower the heat shrinkage due to the chain scission. The effect of temperature at which extension is carried out on heat shrinkage is marginal. The irradiated (radiation dose 50 kGy and TMPTMA level 1%) EVA tubes of different dimensions expanded in a laboratory grade tube expander show similar behaviour at 453K and 60 s. The X-ray and DSC studies reveal that the crystallinity increases on stretching due to orientation of chains and it decreases to a considerable extent on heat shrinking. The theoretical and experimental values of heat shrinkage for tubes and rectangular strips are in good accord, when the radiation dose is 50 kGy and TMPTMA level 1%. (author).

  5. Modification of Biodegradable Polyesters Using Electron Beam

    Directory of Open Access Journals (Sweden)

    M. Suhartini

    2013-12-01

    Full Text Available Poly(4-Hydroxybutirat P4HB, Poly(butylene succinate-co-adipate PBSA and Poly(-caprolactone PCL were electron beam (EB-irradiated. Poly(4-Hydroxybutirat was irradiated without any polyfunctional monomers (PFM. While PBSA and PCL were irradiated in the presence of polyfunctional monomers such as Trimethallyl isocyanurate (TMAIC, Polyethyleneglycol dimethacrylate (2G, 4G, Trimethylolpropane trimethacrylate (TMPT and Tetramethylolmethane tetraacrylate (A-TMMT at ambient temperature. Aim of the study is to improve the properties of biodegradable polyester. It was pointed out that crosslinking yield of P4HB (6.39% gel was formed at dose of 90 kGy irradiated in vacuum conditions. Radiation degradation promoted, when P4HB was irradiated in air. The optimum crosslinking yield of PCL and PBSA respectively, were formed in the presence of 1% TMAIC at dose of 50 kGy. The biodegradability of the crosslinked PBSA evaluated by soil burial test is slightly retarded by increasing crosslinking yields.

  6. Onorbit electron beam welding experiment definition

    Science.gov (United States)

    1989-01-01

    The proposed experiment design calls for six panels to be welded, each having unique characteristics selected to yield specific results and information. The experiment is completely automated and the concept necessitated the design of a new, miniaturized, self-contained electron beam (EB) welding system, for which purpose a separate IR and D was funded by the contractor, Martin Marietta Corporation. Since future tasks beyond the proposed experiment might call for astronauts to perform hand-held EB gun repairs or for the gun to be interfaced with a dexterous robot such as the planned flight telerobotic servicer (FTS), the EB gun is designed to be dismountable from the automated system. In the experiment design, two separate, identical sets of weld panels will be welded, one on earth in a vacuum chamber and the other onorbit in the aft cargo bay of an orbiter. Since the main objective of the experiment is to demonstrate that high quality welds can be achieved under onorbit conditions, the welds produced will be subjected to a wide range of discriminating non-destructive Q.C. procedures and destructive physical tests. However, advantage will be taken of the availability of a fairly large quantity of welded material in the two series of welded specimens to widen the circle of investigative talent by providing material to academic and scientific institutions for examination.

  7. Electron beam irradiation of fluoropolymers containing polyethers

    Energy Technology Data Exchange (ETDEWEB)

    Bucio, E. [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico); Burillo, G. [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico)], E-mail: burillo@nucleares.unam.mx; Tapia, F. [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico); Adem, E. [Departamento de Fisica Experimental, Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico); Cedillo, G. [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico); Cassidy, P.E. [Department of Chemistry and Biochemistry, Texas State University, San Marcos, TX 78666 (United States)

    2009-02-15

    A highly fluorinated monomer, 1,3-bis(1,1,1,3,3,3-hexafluoro-2-pentafluorophenyl methoxy-2-propyl)benzene (12F-FBE) was polymerized with some diphenols by polycondensation and then was electron beam irradiated between 100 and 1000 kGy to determine degradation radiochemistry yield (G{sub s}) by gel permeation chromatography (GPC). The samples were characterized after irradiation by DSC, FTIR, and nuclear magnetic resonance (NMR). The fluoropolymers show apparent degradation in mechanical properties at 300 kGy, except 12F-FBE polymerized with biphenol and bisphenol A, when they did not show any apparent physical change up to 300 kGy; and continue to be flexible and transparent, with a radiochemical yield scission (G{sub s}) of 0.75, 0.53, 0.88, and 0.38 for 12F-FBE/SDL aliphatic, 12F-FBE/biphenol, 12F-FBE/bisphenol A, and 12F-FBE/bisphenol O, respectively. The number average molecular weights for three of the polymers decrease upon 1000 kGy irradiation to 10% of their original values; however, the polymer from bisphenol A is much more stable and its M{sub n} decreases to only 24% of origin0008.

  8. Fast Electron Beam Simulation and Dose Calculation

    CERN Document Server

    Trindade, A; Peralta, L; Lopes, M C; Alves, C; Chaves, A

    2003-01-01

    A flexible multiple source model capable of fast reconstruction of clinical electron beams is presented in this paper. A source model considers multiple virtual sources emulating the effect of accelerator head components. A reference configuration (10 MeV and 10x10 cm2 field size) for a Siemens KD2 linear accelerator was simulated in full detail using GEANT3 Monte Carlo code. Our model allows the reconstruction of other beam energies and field sizes as well as other beam configurations for similar accelerators using only the reference beam data. Electron dose calculations were performed with the reconstructed beams in a water phantom and compared with experimental data. An agreement of 1-2% / 1-2 mm was obtained, equivalent to the accuracy of full Monte Carlo accelerator simulation. The source model reduces accelerator simulation CPU time by a factor of 7500 relative to full Monte Carlo approaches. The developed model was then interfaced with DPM, a fast radiation transport Monte Carlo code for dose calculati...

  9. Electron beam modification of vanadium dioxide oscillators

    Energy Technology Data Exchange (ETDEWEB)

    Belyaev, Maksim; Velichko, Andrey; Putrolaynen, Vadim; Perminov, Valentin; Pergament, Alexander [Petrozavodsk State University, Petrozavodsk (Russian Federation)

    2017-03-15

    The paper presents the results of a study of electron-beam modification (EBM) of VO{sub 2}-switch I-V curve threshold parameters and the self-oscillation frequency of a circuit containing such a switching device. EBM in vacuum is reversible and the parameters are restored when exposed to air at pressure of 150 Pa. At EBM with a dose of 3 C cm{sup -2}, the voltages of switching-on (V{sub th}) and off (V{sub h}), as well as the OFF-state resistance R{sub off}, decrease down to 50% of the initial values, and the oscillation frequency increases by 30% at a dose of 0.7 C cm{sup -2}. Features of physics of EBM of an oscillator are outlined considering the contribution of the metal and semiconductor phases of the switching channel. Controlled modification allows EBM forming of switches with preset parameters. Also, it might be used in artificial oscillatory neural networks for pattern recognition based on frequency shift keying. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Non-vacuum electron-beam carburizing and surface hardening of mild steel

    Energy Technology Data Exchange (ETDEWEB)

    Bataev, I.A., E-mail: ivanbataev@ngs.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Golkovskii, M.G., E-mail: M.G.Golkovski@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, Lavrentieva Prospect 11, 630090 Novosibirsk (Russian Federation); Losinskaya, A.A., E-mail: anna.losinskaya@mail.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Bataev, A.A., E-mail: bataev@adm.nstu.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Popelyukh, A.I., E-mail: aip13@mail.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation); Hassel, T., E-mail: hassel@iw.uni-hannover.de [Leibniz University, Welfengarten 1, 30167 Hannover (Germany); Golovin, D.D., E-mail: ddgolovin@yandex.ru [Novosibirsk State Technical University, K. Marks 20, 630092 Novosibirsk (Russian Federation)

    2014-12-15

    Highlights: • Steel specimens were carburized by non-vacuum electron-beam cladding. • The depth of the clad layers reached 2.6 mm. • The cladding rate was 1.8 m{sup 2}/h, the quenching rate 12.6 m{sup 2}/h. • The microhardness of the quenched and tempered layers reached 8 GPa. - Abstract: In this paper, we study the structure, microhardness, and tribological properties of surface layers of mild (0.19% C) steel, which was formed by electron-beam cladding with an iron–graphite powder mixture followed by quenching and tempering. A 1.4 MeV electron beam that was extracted into air was used. Cladding of steel with the iron–graphite mixture at a beam current of 24 and 26 mA formed a hypoeutectic cast iron layer (2.19% C) and a hypereutectoid steel (1.57% C) layer, which were 2.0 and 2.6 mm thick, respectively. The microhardness of the surface-quenched and tempered steel and cast iron layers was 7 and 8 GPa, respectively. Electron-beam quenching of the surface layers of hypoeutectic cast iron was accompanied with multiple cracking. During the quenching of the 1.57% C steel layer, crack formation was not observed. In friction tests against fixed and loose abrasive particles, the surface layers of hypereutectoid steel and hypoeutectic cast iron that were produced by electron-beam cladding and quenching had lower wear rates than mild steel after pack carburizing, quenching, and tempering. In the sliding wear tests, the cast iron clad layer, which was subjected to electron-beam quenching and tempering, exhibited the highest wear resistance. Electron-beam treatment can be used to harden local areas of large workpieces. It is reasonable to treat clad layers of high-carbon steel with electron-beam quenching and tempering. To prevent multiple cracking, white cast iron layers should not be quenched.

  11. Electron Beam Welding of Thick Copper Material

    Energy Technology Data Exchange (ETDEWEB)

    Broemssen, Bernt von [IVF Industriforskning och utveckling AB, Stockholm (Sweden)

    2002-08-01

    The purpose of this study was to review the two variants of the Electron Beam Welding (EBW) processes developed (or used) by 1- SKB, Sweden with assistance from TWI, England and 2 - POSIVA, Finland with assistance from Outokumpu, Finland. The aim was also to explain the principle properties of the EBW method: how it works, the parameters controlling the welding result but also giving rise to benefits, and differences between the EBW variants. The main conclusions are that both SKB and POSIVA will within a few years succeed to qualify their respective EBW method for welding of copper canisters. The Reduced Pressure EBW that SKB use today seems to be very promising in order to avoid root defects. If POSIVA does not succeed to avoid root defects with the high vacuum method and the beam oscillation technique it should be possible for POSIVA to incorporate the Reduced Pressure technique albeit with significant changes to the EBW equipment. POSIVA has possibly an advantage over SKB with the beam oscillation technique used, which gives an extra degree of freedom to affect the weld quality. The beam oscillation could be of importance for closing of the keyhole. Before EBW of lids, the material certification showing the alloy content (specifying min and max impurity percentages) and the mechanical properties should be checked. The welded material needs also to be tested for mechanical properties. If possible the weld should have a toughness level equal to that of the unwelded parent material. Specifically some conclusions are reported regarding the SKB equipment. Suggestions for further development are also given in the conclusion chapter.

  12. Effects of electron-beam irradiation on HDPE/Brazil nut shell fiber composite

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Maiara S.; Sartori, Mariana N.; Oliveira, Rene R.; Moura, Esperidiana A.B., E-mail: maiara.sferreira@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    In recent years, research on the replacement of synthetic fibers by natural fibers as reinforcement in thermoplastic composites has increased dramatically due to the advantages of natural fibers, such as low density, low cost, environmental appeal and recyclability. In the present work, the influence of electron-beam irradiation on mechanical properties of HDPE and HDPE/Brazil Nut Shell (Bertholletia excelsa) fiber compositive was investigated. The HDPE composite reinforced with 5% or 10%, by weight of Brazil nut shell fiber powder with particle sizes equal or smaller than 250 μm were obtained by extrusion, using a twin screw extruder. The materials were irradiated at 200 kGy using a 1.5 MeV electron beam accelerator, at room temperature in presence of air. The irradiated and non-irradiated specimens tests samples were submitted to mechanical and thermo-mechanical tests, scanning electron microscopy (SEM), X-Ray diffraction (XRD) and sol-gel analysis and the correlation between their properties was discussed. The results showed significant changes in HDPE mechanical and thermo-mechanical properties due to Brazil nut shell fibers addition and electron-beam irradiation. The surface of the cryo fractured composite samples irradiated showed important visual changes which suggest a better fiber-matrix interfacial adhesion, due to irradiation treatment. These results showed that it is possible to get interesting property gains by using waste from renewable sources instead of the traditional ones and electron-beam radiation treatment. (author)

  13. Dose delivery accuracy of therapeutic photon and electron beams at low monitor unit settings

    Energy Technology Data Exchange (ETDEWEB)

    Ravikumar, M.; Al Asmary, M.A.; Sultan, R.A.; Al Ghamdi, H.A. [Oncology Center, King Abdul Aziz Hospital and Oncology Center, Jeddah (Saudi Arabia)

    2005-12-01

    Purpose: dose delivery accuracy at low monitor units (LMU) was evaluated for photon and electron beams. Knowledge of this study is required for few dosimetric applications and to know the dose delivered to the patient when the treatment is delivered with few monitor units (MU). Material and methods: dose measurements were carried out for photon and electron beams with 0.6 cm{sup 3} PTW ion chamber in white polystyrene phantom at D{sub max} with a field size of 10 x 10 cm{sup 2} at 100 cm FSD. The relative dose, which is the ratio of dose delivered per MU at the testing to that of the calibration condition, was found out. Results: significant deviation (+20% to +25%) in dose delivery was noticed for photon and electron beams (+39% to +45%) at LMU settings. Slightly higher inaccuracy in dose delivery was noticed for 6-MV compared to 18-MV photons. The deviation in dose delivery for electron beams was found to be energy-independent and the pattern of variation was similar for all electron energies. Conclusion: the dose delivery accuracy at LMU settings has to be ascertained before implementing conformal and IMRT (intensity-modulated radiotherapy) techniques. When there is dose nonlinearity, the treatment delivered with multiple small MU settings can result in significant error in dose delivery. (orig.)

  14. Electron beam accelerator: A new tool for environmental preservation in Malaysia

    Science.gov (United States)

    Hashim, Siti Aiasah; Bakar, Khomsaton Abu; Othman, Mohd Nahar

    2012-09-01

    Electron beam accelerators are widely used for industrial applications such as surface curing, crosslinking of wires and cables and sterilization/ decontamination of pharmaceutical products. The energy of the electron beam determines the type of applications. This is due to the penetration power of the electron that is limited by the energy. In the last decade, more work has been carried out to utilize the energetic electron for remediation of environmental pollution. For this purposes, 1 MeV electron beam accelerator is sufficient to treat wastewater from textile industry and flue gases from fossil fuel combustions. In Nuclear Malaysia, a variable energy Cockroft Walton type accelerator has been utilized to initiate investigations in these two areas. An electron beam flue gas treatment test rig was built to treat emission from diesel combustion, where it was found that using EB parameters of 1MeV and 12mA can successfully remove at least 80% of nitric oxide in the emission. Wastewater from textile industries was treated using combination of biological treatment and EB. The initial findings indicated that the quality of water had improved based on the CODCr, BOD5 indicators.

  15. Electron beam accelerator: A new tool for environmental preservation in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Hashim, Siti Aiasah; Bakar, Khomsaton Abu; Othman, Mohd Nahar [Malaysian Nuclear Agency, Bangi, 43000, Kajang Selangor (Malaysia)

    2012-09-26

    Electron beam accelerators are widely used for industrial applications such as surface curing, crosslinking of wires and cables and sterilization/ decontamination of pharmaceutical products. The energy of the electron beam determines the type of applications. This is due to the penetration power of the electron that is limited by the energy. In the last decade, more work has been carried out to utilize the energetic electron for remediation of environmental pollution. For this purposes, 1 MeV electron beam accelerator is sufficient to treat wastewater from textile industry and flue gases from fossil fuel combustions. In Nuclear Malaysia, a variable energy Cockroft Walton type accelerator has been utilized to initiate investigations in these two areas. An electron beam flue gas treatment test rig was built to treat emission from diesel combustion, where it was found that using EB parameters of 1MeV and 12mA can successfully remove at least 80% of nitric oxide in the emission. Wastewater from textile industries was treated using combination of biological treatment and EB. The initial findings indicated that the quality of water had improved based on the COD{sub Cr}, BOD{sub 5} indicators.

  16. Methacrylamide Copolymer Resists For Electron Beam Lithography

    Science.gov (United States)

    Namaste, Y. M. N.; Obendorf, S. K.; Rodriguez, F.

    1986-07-01

    Polymethacrylamide (PMAAm) and copolymers of MAAm with methyl methacrylate were synthesized and evaluated for their applicability to electron beam lithography. The sensitivity of PMAAm has previously been reported as less than 1 μC/cm2, with thermal stability at temperatures up to 330°C.' Despite these claims, further lithographic evaluation of this resist system is apparently absent from the literature. This research was conducted to further investigate the lithographic performance of these resists and to determine their sensitivity using current definitions. Using PMAAm homopolymer (Mw = 8.1 x 105), with a 15 minute prebake at 200°C, the lithographic results were much poorer than expected. Patterns exposed to doses of 10 μC/cm2 or lower could not be developed using water as the developing solvent. Forced developing with Na2SiO3 solution (pH=10) developed lower doses than water, but much greater thinning was observed. An unexposed thinning of 10% occurred when developing exposures of 15 μC/cm2 with water, and 40 μC/cm2 with Na2SiO3 solution (20 KV). Swelling of the unexposed polymer and some adhesion problems were observed. The high sensitivity previously reported for PMAAm' can not be attributed solely to chain scission efficiency (Gs), which has been reported to be only 1.5 times that of PMMA (Gs determined by Y-irradiation). An induction period in the dissolution of unexposed polymer has also been sugggested as contributing to the sensitivity of this resist. In the present work, dissolution induction periods were observed with laser interferometry for the unexposed films, but the magnitude of these induction periods could not account for a large enhancement of sensitivity. Imide crosslink formation may have been responsible for the previously reported sensitivity of PMAAm.' In the present work, imid formation was not observed, either after prebaking coated wafers at 180 to 240°C or heating of polymer solutions for 7 hours at 80°C. Apparently, the

  17. Tungsten spectroscopy at the Livermore electron beam ion trap facility

    National Research Council Canada - National Science Library

    Clementson, J; Beiersdorfer, P; Brown, G.V; Gu, M.F; Lundberg, H; Podpaly, Y; Trabert, E

    2011-01-01

    .... In this paper, an overview of recent results from the Livermore WOLFRAM spectroscopy project is presented, which includes experimental investigations at the EBIT-I and SuperEBIT electron beam ion traps...

  18. Optical circular deflector with attosecond resolution for ultrashort electron beam

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2017-05-01

    Full Text Available A novel method using high-power laser as a circular deflector is proposed for the measurement of femtosecond (fs and sub-fs electron beam. In the scheme, the electron beam interacts with a laser pulse operating in a radially polarized doughnut mode (TEM_{01^{*}} in a helical undulator, generating angular kicks along the beam in two directions at the same time. The phase difference between the two angular kicks makes the beam form a ring after a propagation section with appropriate phase advance, which can reveal the current profile of the electron beam. Detailed theoretical analysis of the method and numerical results with reasonable parameters are both presented. It is shown that the temporal resolution can reach up to ∼100 attosecond, which is a significant improvement for the diagnostics of ultrashort electron beam.

  19. Brushless dc motor uses electron beam switching tube as commutator

    Science.gov (United States)

    Studer, P.

    1965-01-01

    Electron beam switching tube eliminates physical contact between rotor and stator in brushless dc motor. The tube and associated circuitry control the output of a dc source to sequentially energize the motor stator windings.

  20. Interpenetrating Polymer Network (IPN) Adhesives for Electron Beam Cure

    National Research Council Canada - National Science Library

    Sands, James

    2000-01-01

    Electron beam (e-beam)-processed polymer adhesives have historically performed poorly compared to traditional adhesive technologies due to a lack of toughness engineered into these new types of adhesive materials...

  1. Nanoscale metamaterial light source driven by electron beam

    OpenAIRE

    ADAMO, G.; MacDonald, K. F.; De Angelis, F.; Di Fabrizio, E.; Zheludev, N. I.

    2011-01-01

    We demonstrate a new generation of free-space and fibre-coupled tuneable light sources based on nanostructured photonic metamaterials driven by free-electrons beams. Emission wavelengths are determined by metamaterial resonant modes and electron energies.

  2. Ribbon Reduces Spiking in Electron-Beam Welding

    Science.gov (United States)

    Olson, R. E.

    1984-01-01

    Spiking in electron-beam welding reduced by placing high-vapor-pressure substance along path of electron beam. Strip of metal having vapor pressure higher than base metal at same temperature placed in slot machined along weld line. Strip vaporizes as beam strikes it, and vapor pressure keeps surface tension from closing off top of channel. Technique used successfully on nickel alloys and aluminum alloys and effective on steel and titanium.

  3. Ionic liquids influence on the surface properties of electron beam irradiated wood

    Energy Technology Data Exchange (ETDEWEB)

    Croitoru, Catalin [“Transilvania” University of Brasov, Product Design and Environment Department, 29 Eroilor Str., 500036, Brasov (Romania); Patachia, Silvia, E-mail: st.patachia@unitbv.ro [“Transilvania” University of Brasov, Product Design and Environment Department, 29 Eroilor Str., 500036, Brasov (Romania); Doroftei, Florica; Parparita, Elena; Vasile, Cornelia [“Petru Poni” Institute of Macromolecular Chemistry, Physical Chemistry of Polymers Department, 41A Gr. Ghica Voda Alley, Iasi (Romania)

    2014-09-30

    Highlights: • Wood veneers impregnated with three imidazolium-based ionic liquids and irradiated with electron beam were studied by FTIR-ATR, SEM/EDX, AFM, contact angle and image analysis. • ILs preserve the surface properties of the wood (surface energy, roughness, color) upon irradiation, in comparison with the reference wood, but the surface composition is changed by treatment with IL-s, mainly with 1-butyl-3-methylimidazolium tetrafluoroborate. • Under electron beam irradiation covalent bonding of the imidazolium moiety to wood determines a higher resistance to water penetration and spreading on the surface. - Abstract: In this paper, the influence of three imidazolium-based ionic liquids (1-butyl-3-methylimidazolium tetrafluoroborate, 1-butyl-3-methylimidazolium hexafluorophosphate and 1-hexyl-3-methylimidazolium chloride) on the structure and surface properties of sycamore maple (Acer pseudoplatanus) veneers submitted to electron beam irradiation with a dose of 50 kGy has been studied by using Fourier transform infrared spectroscopy, as well as image, scanning electron microscopy/SEM/EDX, atomic force microscopy and contact angle analysis. The experimental results have proven that the studied ionic liquids determine a better preservation of the structural features of wood (cellulose crystallinity index and lignin concentration on the surface) as well as some of surface properties such as surface energy, roughness, color upon irradiation with electron beam, in comparison with the reference wood, but surface composition is changed by treatment with imidazolium-based ionic liquids mainly with 1-butyl-3-methylimidazolium tetrafluoroborate. Also, under electron beam irradiation covalent bonding of the imidazolium moiety to wood determines a higher resistance to water penetration and spreading on the surface.

  4. Design of electron beam accelerator for microwave application

    Science.gov (United States)

    Prestwich, K. R.

    Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx 1 microsec) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. Alternatively, a low voltage PFN followed by a highly coupled transformer can be used. Basic design principles for all of the above subsystems are discussed. Both PFLs and PFNs can also be operated as inductive storage systems with opening switches.

  5. Application of Concentrated Electron Beams in Extra-Vacuum Technologies

    Science.gov (United States)

    Gorshkov, Oleg; Iliin, A. A.; Lovtsov, A. S.; Rizakhanov, R. N.

    2001-10-01

    At present time the rise in development of the technology with using the concentrated electron beams in gas with atmospheric pressure is observed. Besides the technologies, which are usually carried out in vacuum and connected with surface modification by the concentrated energy flows (welding, cutting, metal surface hardening), at present time the plasma chemical processes become of greater interest. These are processes with using the beam of fast electrons to initiate the plasma chemical reactions. One of such technologies is gas cleaning of the toxic impurities (nitrogen oxides and sulfur oxides and etc.) The electron-beam gas cleaning of the toxic impurities (for example Ebara-process) is based on radiation-enhanced combining of toxic impurities. The disadvantage of this method are high level of consumed power during the gas cleaning and difficulties in devices development for the output of electron beam with megawatt unit power with foil outlet, as the facilities of this very power are necessary for the real industrial application. These problems can be solved by using the devices with concentrated electron beam output into the atmosphere. In this case the beam is transported into the dense gas through the system of lock chambers, independently pumped. But unlike the beam, output through the foil window, the concentrated electron beam is characterized by the noticeable spatial irregularity in distribution of temperature, plasma concentration and area of radiation. This paper is devoted to consideration of using the concentrated electron beams in extra-vacuum technologies.

  6. High energy gain electron beam acceleration by 100TW laser

    Energy Technology Data Exchange (ETDEWEB)

    Kotaki, Hideyuki; Kando, Masaki; Kondo, Shuji; Hosokai, Tomonao; Kanazawa, Shuhei; Yokoyama, Takashi; Matoba, Toru; Nakajima, Kazuhisa [Japan Atomic Energy Research Inst., Kizu, Kyoto (Japan). Kansai Research Establishment

    2001-10-01

    A laser wakefield acceleration experiment using a 100TW laser is planed at JAERI-Kansai. High quality and short pulse electron beams are necessary to accelerate the electron beam by the laser. Electron beam - laser synchronization is also necessary. A microtron with a photocathode rf-gun was prepared as a high quality electron injector. The quantum efficiency (QE) of the photocathode of 2x10{sup -5} was obtained. A charge of 100pC from the microtron was measured. The emittance and pulse width of the electron beam was 6{pi} mm-mrad and 10ps, respectively. In order to produce a short pulse electron beam, and to synchronize between the electron beam and the laser pulse, an inverse free electron laser (IFEL) is planned. One of problems of LWFA is the short acceleration length. In order to overcome the problem, a Z-pinch plasma waveguide will be prepared as a laser wakefield acceleration tube for 1 GeV acceleration. (author)

  7. Electron Beam Welding of Gear Wheels by Splitted Beam

    Science.gov (United States)

    Dřímal, Daniel

    2014-06-01

    This contribution deals with the issue of electron beam welding of high-accurate gear wheels composed of a spur gearing and fluted shaft joined with a face weld for automotive industry. Both parts made of the high-strength low-alloy steel are welded in the condition after final machining and heat treatment, performed by case hardening, whereas it is required that the run-out in the critical point of weldment after welding, i. e. after the final operation, would be 0.04 mm max.. In case of common welding procedure, cracks were formed in the weld, initiated by spiking in the weld root. Crack formation was prevented by the use of an interlocking joint with a rounded recess and suitable welding parameters, eliminating crack initiation by spiking in the weld root. Minimisation of the welding distortions was achieved by the application of tack welding with simultaneous splitting of one beam into two parts in the opposite sections of circumferential face weld attained on the principle of a new system of controlled deflection with digital scanning of the beam. This welding procedure assured that the weldment temperature after welding would not be higher than 400 °C. Thus, this procedure allowed achieving the final run-outs in the critical point of gearwheels within the maximum range up to 0.04 mm, which is acceptable for the given application. Accurate optical measurements did not reveal any changes in the teeth dimensions.

  8. Use of electron beam on aflatoxins degradation in coconut agar

    Energy Technology Data Exchange (ETDEWEB)

    Rogovschi, Vladimir D.; Nunes, Thaise C.F.; Villavicencio, Anna L.C.H. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: vrogovschi@ipen.br; Aquino, Simone; Goncalez, Edlayne [Instituto Biologico (IB-SP), Sao Paulo, SP (Brazil); Correa, Benedito [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Ciencias Biomedicas

    2009-07-01

    The fungi Aspergillus flavus are capable of producing toxic metabolites, such as aflatoxin, that is one of the most important human carcinogens, according to the 'International Agency for Research on Cancer'. The aim of this study was to compare the effect of electron beam irradiation on degradation of aflatoxin B1 present in laboratorial residues with a dose of 0 kGy and 5.0 kGy. The fungi were cultivated in potato dextrose agar (PDA) for 7 days and transferred to a coconut agar medium, incubated at a temperature of 25 deg C for 14 days to produce the laboratorial wastes (coconut agar) containing aflatoxins. The samples were conditioned in petri dish for radiation treatment of contaminated material and processed in the Electron Accelerator with 0 kGy and 5.0 kGy. Aflatoxin B{sub 1} was extracted with chloroform and separated on a thin layer chromatography plate (TLC) with chloroform: acetone (9:1). All the control and irradiated samples were analyzed in a Shimadzu Densitometer. The detection limit of this methodology is 0.1{mu}g kg{sup -1}. The results indicate that the irradiated samples had a reduction of 75.49 % in the analyzed dose. (author)

  9. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  10. Electron beam melting of advanced materials and structures

    Science.gov (United States)

    Mahale, Tushar Ramkrishna

    Layered manufacturing has for long been used for the fabrication of non-functional parts using polymer-based processes. Developments in laser beam and electron beam welding technologies and their adoption to layered manufacturing has made it possible to fabricate high-density functional parts in metal irrespective of the level of complexity. The Electron Beam Melting (EBM) process by Arcam AB is one such layered manufacturing process that utilizes a focused electron beam to process metal powder, layer by layer, in a vacuum environment. Research conducted as part of this body of work looks into the development of both bulk materials in the form of metal alloys and ceramic metal-matrix composites as well as the development of tunable mechanical & thermal metamaterials. Simulation models to approximate electron beam melting were suggested using commercial finite element analysis packages. A framework was developed based on the finite difference method to simulate layered manufacturing using Arcam AB's electron beam melting process. The outputs from the simulation data could be used to better understand the local melting, grain evolution, composition and internal stresses within freeform-fabricated metal parts.

  11. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  12. Manipulation and electron-oscillation-measurement of laser accelerated electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kotaki, H; Hayashi, Y; Kawase, K; Mori, M; Kando, M; Homma, T; Koga, J K; Daido, H; Bulanov, S V, E-mail: kotaki.hideyuki@jaea.go.jp [Advanced Photon Research Center, Japan Atomic Energy Agency, 8-1-7, Umemidai, Kizugawa, Kyoto (Japan)

    2011-01-15

    Monoenergetic electron beams have been generated in the self-injection scheme of laser acceleration. In applications of these laser accelerated electron beams, stable and controllable electron beams are necessary. A stable electron beam is generated in the self-injection scheme by using a nitrogen gas jet target. We found the profile of the electron beam was manipulated by rotating the laser polarization. The electron beam is in the first bucket of the wake wave. In the energy space, transverse oscillation is observed when the laser pulse has S-polarization. The direction of the electron beam is controlled by the gas jet position.

  13. Refractory phases synthesis at the surface microalloying using a wide aperture electron beam

    Science.gov (United States)

    Fedorov, S. V.; Htet Swe, Min

    2017-05-01

    The experimental results prove the ability to realize technology of chemical heat treatment of some materials by surface microalloying using a wide-aperture low-energy high-current electron beam. Such layers were produced due to initiating exothermic chemical self-propagating high-temperature reactions in the thermal explosion mode between the base and the thin film covered on the base. New phase compounds in reaction products were found.

  14. Electron Beam Quality Determination Through Fricke Xylenol Gel Dosimeter

    Science.gov (United States)

    Petchevist, P. C. D.; Moreira, M. V.; de Almeida, A.

    2009-03-01

    According to the IAEA TRS-398 protocol, a parallel plate ionization chamber is recommended to be used in electron dosimetry. The important dosimetric parameters such as R100 and R50, inferred from the percentage depth dose (PDD) curve, allow to obtain the electron beam average energy at the water phantom surface (material equivalent to the soft tissue). In this work, a chemical dosimeter based on the Fe(II) to Fe(III) oxidation was used to obtain the average energies from electrons beams (from nominal energies of 5, 8 and 10 MeV) and related parameters of R100, R50 and zref. These energies obtained through the Fricke Xylenol Gel (FXG) were compared to those with a parallel plate ionization chamber, following the cited protocol, which showed no significant differences. From these measurements one can conclude the FXG applicability for R100, R50 and electron beam average energy determination.

  15. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  16. 3D shaping of electron beams using amplitude masks

    Energy Technology Data Exchange (ETDEWEB)

    Shiloh, Roy, E-mail: royshilo@post.tau.ac.il; Arie, Ady

    2017-06-15

    Highlights: • Electron beams are shaped in 3D with examples of curves and lattices. • Computer generated holograms are manifested as binary amplitude masks. • Applications in electron-optical particle trapping, manipulation, and synthesis. • Electron beam lithography fabrication scheme explained in detail. • Measurement paradigms of 3D shaped beams are discussed. - Abstract: Shaping the electron wavefunction in three dimensions may prove to be an indispensable tool for research involving atomic-sized particle trapping, manipulation, and synthesis. We utilize computer-generated holograms to sculpt electron wavefunctions in a standard transmission electron microscope in 3D, and demonstrate the formation of electron beams exhibiting high intensity along specific trajectories as well as shaping the beam into a 3D lattice of hot-spots. The concepts presented here are similar to those used in light optics for trapping and tweezing of particles, but at atomic scale resolutions.

  17. Solid gold nanostructures fabricated by electron beam deposition

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Madsen, Dorte Nørgaard; Rasmussen, A.M.

    2003-01-01

    and bridges. Transmission electron microscopy was used to study how the composition of these structures was affected when the background gas in the ESEM chamber and the electron beam parameters were varied. The nanostructures were layered composites of up to three different materials each characterized......Direct writing with gold by electron beam deposition is a method for rapid fabrication of electrically conducting nanostructures. An environmental scanning electron microscope (ESEM) equipped with a source of the precursor gas dimethylacetylacetonate gold(Ill) was used to fabricate nanoscale tips...... by a certain range of gold/carbon ratios. Above a certain threshold of ESEM chamber water vapor pressure and a certain threshold of electron beam current, the deposited tips contained a solid polycrystalline gold core. The deposition technique was used to fabricate free-standing nanowires and to solder free...

  18. Electron beam irradiation processing for industrial and medical applications

    Science.gov (United States)

    Ozer, Zehra Nur

    2017-09-01

    In recent years, electron beam processing has been widely used for medical and industrial applications. Electron beam accelerators are reliable and durable equipments that can produce ionizing radiation when it is needed for a particular commercial use. On the industrial scale, accelerators are used to generate electrons in between 0.1-100 MeV energy range. These accelerators are used mainly in plastics, automotive, wire and electric cables, semiconductors, health care, aerospace and environmental industries, as well as numerous researches. This study presents the current applications of electron beam processing in medicine and industry. Also planned study of a design for such a system in the energy range of 200-300 keV is introduced.

  19. Generation of runaway electron beams in high-pressure nitrogen

    Science.gov (United States)

    Tarasenko, V. F.; Burachenko, A. G.; Baksht, E. Kh

    2017-07-01

    In this paper the results of experimental studies of the amplitude-temporal characteristics of a runaway electron beam, as well as breakdown voltage in nitrogen are presented. The voltage pulses with the amplitude in incident wave ≈120 kV and the rise time of ≈0.3 ns was used. The supershort avalanche electron beam (SAEB) was detected by a collector behind the flat anode. The amplitude-time characteristics of the voltage and SAEB current were studied with subnanosecond time resolution. The maximum pressure at which a SAEB is detectable by collector was ∼1 MPa. This pressure increases with decreasing the voltage rise time. The waveforms of the discharge and runaway electron beam currents was synchronized with the voltage pulses. The mechanism of the runaway electron generation in atmospheric-pressure gases is analyzed on the basis of the obtained experimental data.

  20. Measuring the electron beam energy in a magnetic bunch compressor

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Kirsten

    2010-09-15

    Within this thesis, work was carried out in and around the first bunch compressor chicane of the FLASH (Free-electron LASer in Hamburg) linear accelerator in which two distinct systems were developed for the measurement of an electron beams' position with sub-5 {mu}m precision over a 10 cm range. One of these two systems utilized RF techniques to measure the difference between the arrival-times of two broadband electrical pulses generated by the passage of the electron beam adjacent to a pickup antenna. The other system measured the arrival-times of the pulses from the pickup with an optical technique dependent on the delivery of laser pulses which are synchronized to the RF reference of the machine. The relative advantages and disadvantages of these two techniques are explored and compared to other available approaches to measure the same beam property, including a time-of-flight measurement with two beam arrival-time monitors and a synchrotron light monitor with two photomultiplier tubes. The electron beam position measurement is required as part of a measurement of the electron beam energy and could be used in an intra-bunch-train beam-based feedback system that would stabilize the amplitude of the accelerating field. By stabilizing the accelerating field amplitude, the arrival-time of the electron beam can be made more stable. By stabilizing the electron beam arrival-time relative to a stable reference, diagnostic, seeding, and beam-manipulation lasers can be synchronized to the beam. (orig.)

  1. The polarized electron beam for the SLAC Linear Collider

    Energy Technology Data Exchange (ETDEWEB)

    Woods, M.

    1996-10-01

    The SLAC Linear Collider has been colliding a polarized electron beam with an unpolarized positron beam at the Z{sup 0} resonance for the SLD experiment since 1992. An electron beam polarization of close to 80% has been achieved for the experiment at luminosities up to 8 {center_dot} 10{sup 29} cm{sup {minus}2} s{sup {minus}1}. This is the world`s first and only linear collider, and is a successful prototype for the next generation of high energy electron linear colliders. This paper discusses polarized beam operation for the SLC, and includes aspects of the polarized source, spin transport and polarimetry.

  2. Investigation of effect of electron beam on various polyethylene blends

    CERN Document Server

    Morshedian, J

    2003-01-01

    With regards to the expanding usage of electron beams irradiation in polymer industries such as sterilization of polymeric disposable medical products; cable manufacturing; pipes, heat shrinkable materials, etc. In this project the effect of electron beam on polyethylene used in manufacturing of pipe and heat shrinkable products was studied. Results showed that by increasing the applied dose on samples; the crosslink density would increase and polymers with tertiary carbon atoms in their backbone structure tend to crosslink more readily. The melting temperature and crystallinity percent decreased and degradation temperature increased. Density in low doses decreased and in high doses increased.

  3. Laser and electron beam processing of silicon and gallium arsenide

    Energy Technology Data Exchange (ETDEWEB)

    Narayan, J.

    1979-10-01

    Laser (photon) and electron beams provide a controlled source of heat by which surface layers of silicon and gallium arsenide can be rapidly melted and cooled with rates exceeding 10/sup 80/C/sec. The melting process has been used to remove displacement damage in ion implanted Si and GaAs, to remove dislocations, loops and precipitates in silicon and to study impurity segregation and solubility limits. The mechanisms associated with various phenomena will be examined. The possible impact of laser and electron beam processing on device technology, particularly with respect to solar cells is discussed.

  4. Electron-beam guiding by a reduced-density channel

    Science.gov (United States)

    Welch, D. R.; Bieniosek, F. M.; Godfrey, B. B.

    1990-12-01

    A new regime of density-channel guiding of a relativistic electron beam in air has been found using a three-dimensional charged-particle simulation code, and confirmed in a double-pulse electron-beam experiment. The guiding results from the temperature dependence of the electron-neutral momentum-transfer frequency nu(m). The mechanism does not require a deep channel to obtain a significant guiding force. For the 13-kA MEDEA II (and beams of similar parameters), guiding persists 10 nsec into the beam pulse, with the force per channel displacement as high as 4 G/cm.

  5. Low energy electron beams for industrial and environmental applications

    CERN Document Server

    Skarda, Vlad

    2017-01-01

    EuCARD-2 Workshop, 8-9 December 2016, Warsaw, Poland. Organizers: Science and Technology Facilities Council, UK CERN - The European Organization for Nuclear Research, Switzerland, Institute of Nuclear Chemistry and Technology, Poland, Fraunhofer Institute for Electron Beam and Plasma Technology, Germany, Warsaw University of Technology, Poland. An article presents short information about EuCARD-2 Workshop “Low energy electron beams for industrial and environmental applications”, which was held in December 2016 in Warsaw. Objectives, main topics and expected output of meeting are described. List of organizers is included.

  6. Numerical modeling of electron-beam welding of dissimilar metals

    Science.gov (United States)

    Krektuleva, R. A.; Cherepanov, O. I.; Cherepanov, R. O.

    2016-11-01

    This paper is devoted to numerical modeling of heat transfer processes and estimation of thermal stresses in weld seams created by electron beam welding of heterogeneous metals. The mathematical model is based on a system of equations that includes the Lagrange's variational equation of theory of plasticity and variational equation of M. Biot's principle to simulate the heat transfer processes. The two-dimensional problems (plane strain and plane stress) are considered for estimation of thermal stresses in welds considering differences of mechanical properties of welded materials. The model is developed for simulation of temperature fields and stresses during electron beam welding.

  7. Potential for Fabric Damage by Welding Electron Beam

    Science.gov (United States)

    Fragomeni, James M.; Nunes, Arthur C., Jr.

    1998-01-01

    Welding electron beam effects on Nextel AF-62 ceramic fabric enable a preliminary, tentative interpretation of electron beam fabric damage. Static surface charging does not protect fabric from beam penetration, but penetration occurs only after a delay time. The delay time is thought to be that required for the buildup of outgassing products at the fabric surface to a point where arcing occurs. Extra long delays are noted when the gun is close enough to the surface to be shut off by outgassing emissions. Penetration at long distances is limited by beam attenuation from electronic collisions with the chamber atmosphere.

  8. Tracking on the joint during the electron beam welding

    Science.gov (United States)

    Braverman, V.; Bogdanov, V.; Belozertsev, V.; Uspenskiy, N.

    2016-11-01

    In the article the description of device, which provides automatic positioning of electron beam relative to joint of welded parts during welding, is given. Extremum seeking based on synchronous detection of sensor signal (X-ray or secondary emission) is realized in the device. Measurements are made when beam goes out of the channel following the welding direction. The application of synchronous detection is possible due to the fact that during joint scanning with electron beam harmonics, carrying data about beam position relative to the joint appear in the joint sensor signal spectrum.

  9. Sterilization of ground spices by electron beams irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hashigiwa, Masayuki; Nakachi, Ayako; Kobayashi, Hiroshi [K. Kobayashi and Co., Ltd., Kako, Hyogo (Japan)

    1999-09-01

    Each ground spice (Black Pepper, Turmeric, Ginger, Paprika and Basil), which was packaged into polyethylene film, was irradiated by electron beams at 5 different levels: 2, 4, 6, 8 and 10 kGy. Bacteriological tests for total bacterial count were carried out on spices before and after irradiation, but the tests for microfiora were carried out only before irradiation. Total bacterial count decreased in proportion to the level of electron beams. But the decreasing rate for Turmeric, Ginger and Basil was lower compared with that of other spices. The reason seems that rate of contamination by B. pumilus, which is thought as radiation resistant bacteria, was higher on these spices. (author)

  10. Patterned electrochemical deposition of copper using an electron beam

    Directory of Open Access Journals (Sweden)

    Mark den Heijer

    2014-02-01

    Full Text Available We describe a technique for patterning clusters of metal using electrochemical deposition. By operating an electrochemical cell in the transmission electron microscope, we deposit Cu on Au under potentiostatic conditions. For acidified copper sulphate electrolytes, nucleation occurs uniformly over the electrode. However, when chloride ions are added there is a range of applied potentials over which nucleation occurs only in areas irradiated by the electron beam. By scanning the beam we control nucleation to form patterns of deposited copper. We discuss the mechanism for this effect in terms of electron beam-induced reactions with copper chloride, and consider possible applications.

  11. Electron beam weld development on a Filter Pack Assembly

    Science.gov (United States)

    Dereskiewicz, J. P.

    1994-06-01

    A continuous electron beam welding procedure was developed to replace the manual gas tungsten arc welding procedure on the Filter Pack Assembly. A statistical study was used to evaluate the feasibility of electron beam welding 6061-T6 aluminum covers to A356 cast weldments throughout the joint tolerance range specified on product drawings. Peak temperature exposures were not high enough to degrade the heat sensitive electrical components inside the cast weldment. Actual weldments with alodine coating on the weld joint area were successfully cleaned using a nonmetallic fiberglass brush cleaning method.

  12. Development of hollow electron beams for proton and ion collimation

    CERN Document Server

    Stancari, G.; Kuznetsov, G.; Shiltsev, V.; Still, D.A.; Valishev, A.; Vorobiev, L.G.; Assmann, R.; Kabantsev, A.

    2010-01-01

    Magnetically confined hollow electron beams for controlled halo removal in high-energy colliders such as the Tevatron or the LHC may extend traditional collimation systems beyond the intensity limits imposed by tolerable material damage. They may also improve collimation performance by suppressing loss spikes due to beam jitter and by increasing capture efficiency. A hollow electron gun was designed and built. Its performance and stability were measured at the Fermilab test stand. The gun will be installed in one of the existing Tevatron electron lenses for preliminary tests of the hollow-beam collimator concept, addressing critical issues such as alignment and instabilities of the overlapping proton and electron beams

  13. Development of hollow electron beams for proton and ion collimation

    CERN Document Server

    Stancari, G; Kuznetsov, G; Shiltsev, V; Still, D A; Valishev, A; Vorobiev, L G; Assmann, R; Kabantsev, A

    2012-01-01

    Magnetically confined hollow electron beams for controlled halo removal in high-energy colliders such as the Tevatron or the LHC may extend traditional collimation systems beyond the intensity limits imposed by tolerable material damage. They may also improve collimation performance by suppressing loss spikes due to beam jitter and by increasing capture efficiency. A hollow electron gun was designed and built. Its performance and stability were measured at the Fermilab test stand. The gun will be installed in one of the existing Tevatron electron lenses for preliminary tests of the hollow-beam collimator concept, addressing critical issues such as alignment and instabilities of the overlapping proton and electron beams.

  14. Generation of subnanosecond electron beams in air at atmospheric pressure

    Science.gov (United States)

    Kostyrya, I. D.; Tarasenko, V. F.; Baksht, E. Kh.; Burachenko, A. G.; Lomaev, M. I.; Rybka, D. V.

    2009-11-01

    Optimum conditions for the generation of runaway electron beams with maximum current amplitudes and densities in nanosecond pulsed discharges in air at atmospheric pressure are determined. A supershort avalanche electron beam (SAEB) with a current amplitude of ˜30 A, a current density of ˜20 A/cm2, and a pulse full width at half maximum (FWHM) of ˜100 ps has been observed behind the output foil of an air-filled diode. It is shown that the position of the SAEB current maximum relative to the voltage pulse front exhibits a time shift that varies when the small-size collector is moved over the foil surface.

  15. Use of electron beam irradiation to improve the microbiological safety of Hippophae rhamnoides

    Energy Technology Data Exchange (ETDEWEB)

    Minea, R. [National Institute for Lasers, Plasma and Radiation Physics, Electron Accelerators Department, 409 Atomistilor St., Bucharest-Magurele 077125 (Romania); Nemtanu, M.R. [National Institute for Lasers, Plasma and Radiation Physics, Electron Accelerators Department, 409 Atomistilor St., Bucharest-Magurele 077125 (Romania)], E-mail: monica.nemtanu@inflpr.ro; Manea, S.; Mazilu, E. [S.C. Hofigal Export-Import S.A., 2A Intrarea Serelor St., 75669, Bucharest 4 (Romania)

    2007-09-21

    Sea buckthorn (Hippophae rhamnoides) is increasingly used in food supplements due to its dietary and medicinal compounds with a beneficial role in human diet and health. As many other medicinal plants, sea buckthorn can be contaminated with microorganisms which exerts an important impact on the overall quality of the products. Irradiation is an effective method for food preservation because it is able to destroy pathogenic microorganisms keeping the organoleptic and nutritional characteristics of the foods. The objective of the present study was to investigate the application of electron beam irradiation in order to improve the microbiological safety of sea buckthorn. The experimental results indicated that the electron beam treatment might be a good method to remove undesirable microorganisms from sea buckthorn without significant changes in its active principles.

  16. Development of the techniques for food processing with low-energy electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Todoroki, Setsuko; Hayashi, Toru [National Food Research Inst., Tsukuba, Ibaraki (Japan)

    1999-02-01

    This study aimed to construct a new electron beam irradiation apparatus which allows to perform homogeneous irradiation up to a certain depth of a spherical or granular material through rotating it. And the sterilizing effects of this apparatus on various kinds of spices such as black and white peppers (grains), turmeric (root), coriander (seed), basil (leaves) were investigated to compare with the effects of {gamma}-ray irradiation. Electron beam irradiation was made changing the energy form 200 keV for 15 min to 500 keV for 5 min and a dose-depth curve was drawn for each electron energy. Indicator balls were used to examine the radiation effects. It became possible to make homogeneous irradiation onto a spherical surface of food by using the rotary system of the apparatus. It was demonstrated that satisfactory sterilizing effects as much as those of {gamma}-ray were obtainable by superficial treatments with low-energy electron. (M.N.)

  17. Electron-stimulated purification of platinum nanostructures grown via focused electron beam induced deposition

    Directory of Open Access Journals (Sweden)

    Brett B. Lewis

    2015-04-01

    Full Text Available Platinum–carbon nanostructures deposited via electron beam induced deposition from MeCpPt(IVMe3 are purified during a post-deposition electron exposure treatment in a localized oxygen ambient at room temperature. Time-dependent studies demonstrate that the process occurs from the top–down. Electron beam energy and current studies demonstrate that the process is controlled by a confluence of the electron energy loss and oxygen concentration. Furthermore, the experimental results are modeled as a 2nd order reaction which is dependent on both the electron energy loss density and the oxygen concentration. In addition to purification, the post-deposition electron stimulated oxygen purification process enhances the resolution of the EBID process due to the isotropic carbon removal from the as-deposited materials which produces high-fidelity shape retention.

  18. Hypofractionated electron-beam radiation therapy for keloids: retrospective study of 568 cases with 834 lesions.

    Science.gov (United States)

    Shen, Jie; Lian, Xin; Sun, Yuliang; Wang, Xiaojun; Hu, Ke; Hou, Xiaorong; Sun, Shuai; Yan, Junfang; Yu, Lang; Sun, Xiansong; Li, Wenbo; Wang, Xinhai; Guan, Qiu; Pang, Tingtian; Zhang, Fuquan

    2015-09-01

    We aimed to analyze the outcomes of hypofractionated high-energy electron beam radiotherapy for the treatment of keloids. From February 1998 to January 2012, 568 patients with a total of 834 keloids underwent radiotherapy: 826 lesions with postoperative radiotherapy, and 36 with skin-grafting. Lesion size was >5 cm in 335 keloids. An electron-beam of 6 or 7 MeV was used, with a total dose of 18 Gy (two fractions with a 1-week interval) covering the lesion with a 1-cm margin. The time between surgery and radiotherapy was 24-48 h. Skin-grafted patients underwent radiotherapy 10-15 days after the operation. The median follow-up was 40 months (range: 12-160 months). The local control rate was 88.25% (736/834). The relapse rate was 9.59% (80/834), and the time to relapse was 6-28 months (median: 12 months). Univariate analyses showed that gender, age, keloid size, keloid site, skin grafting, and operation-to-irradiation interval influenced the local control rate. Multivariate analysis showed that the relapse rate was correlated with gender (P = 0.048), age (P irradiation interval (P electron beam radiotherapy for keloids yielded excellent outcomes, especially in cases without skin grafting. Early postoperative radiotherapy with limited hypofractionation could be a good choice for keloid treatment. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  19. Electron beam agrobionanotechnologies for agriculture and food industry enabled by electron accelerators

    Science.gov (United States)

    Pavlov, Y. S.; Revina, A. A.; Souvorova, O. V.; Voropaeva, N. L.; Chekmar, D. V.; Abkhalimov, E. V.; Zavyalov, M. A.; Filippovich, V. P.

    2017-12-01

    Electron beam (EB) radiation technologies have been employed to increase efficiency of biologically active nanochips developed for agricultural plants seed pre-treatment with purpose of enhancing crop yield and productivity. Iron-containing nanoparticles (NPs), synthesized in reverse micelles following known radiation-chemical technique, have served as a multifunctional biologically active and phytosanitary substance of the chips. Porous chip carriers activation has been performed by EB ionization (doze 20kGy) of the active carbons (AC) prepared from agricultural waste and by-products: Jerusalem artichoke (Helianthus tuberosus) straw, rape (Brassica napus L. ssp. oleifera Metzg) straw, camelina (Camelina sativa (L.) Crantz) straw, wheat (Triticum aestivum) straw. Three methods, UV-VIS spectrophotometry, Electron Paramagnetic Resonance (EPR) spectroscopy, cyclic voltammetry (CV) have been used for process control and characterization of radiation-activated and NPs-modified ACs. The results show a notable effect of ACs activation by electron beam radiation, evidenced by FeNPs-adsorption capacity increase. Studies of the impact of Fe NPs-containing nanochip technology on enhancement of seeds germination rate and seedlings vigour suggest that reported electron beam radiation treatment techniques of the ACs from selected agricultural residues may be advantageous for industrial application.

  20. Effects of electron beam irradiation on the microbial growth and quality of beef jerky during storage

    Science.gov (United States)

    Kim, Hyun-Jin; Chun, Ho-Hyun; Song, Hyeon-Jeong; Song, Kyung-Bin

    2010-11-01

    Electron beam irradiation was applied to improve the microbial safety of beef jerky during storage. Beef jerky samples were irradiated at doses of 1, 3, 5, and 10 kGy and stored at 20 °C for 60 d. Microbiological data indicated that the populations of total aerobic bacteria significantly decreased with increasing irradiation dosage. In particular, the populations of total aerobic bacteria were significantly decreased by 1.76 log CFU/g at 10 kJ/m 2, compared to the control. Color measurements showed reduced Hunter L and a values of beef jerky for all the treatments during storage, and the Hunter L, a, and b values of beef jerky were not significantly different among the treatments. Sensory evaluation results also showed that electron beam irradiation did not affect sensory scores in overall during storage. Therefore, the results suggest that electron beam irradiation could be useful in improving the microbial safety without impairing the quality of beef jerky during storage.

  1. Effects of electron beam irradiation on the microbial growth and quality of beef jerky during storage

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun-Jin; Chun, Ho-Hyun; Song, Hyeon-Jeong [Department of Food Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Song, Kyung-Bin, E-mail: kbsong@cnu.ac.k [Department of Food Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2010-11-15

    Electron beam irradiation was applied to improve the microbial safety of beef jerky during storage. Beef jerky samples were irradiated at doses of 1, 3, 5, and 10 kGy and stored at 20 {sup o}C for 60 d. Microbiological data indicated that the populations of total aerobic bacteria significantly decreased with increasing irradiation dosage. In particular, the populations of total aerobic bacteria were significantly decreased by 1.76 log CFU/g at 10 kJ/m{sup 2}, compared to the control. Color measurements showed reduced Hunter L and a values of beef jerky for all the treatments during storage, and the Hunter L, a, and b values of beef jerky were not significantly different among the treatments. Sensory evaluation results also showed that electron beam irradiation did not affect sensory scores in overall during storage. Therefore, the results suggest that electron beam irradiation could be useful in improving the microbial safety without impairing the quality of beef jerky during storage.

  2. Electron Beam Welding of a Depleted Uranium Alloy to Niobium Using a Calibrated Electron Beam Power Density Distribution

    Science.gov (United States)

    Elmer, J. W.; Teruya, A. T.; Terrill, P. E.

    2000-08-01

    Electron beam test welds were made joining flat plates of commercially pure niobium to a uranium-6wt%Nb (binary) alloy. The welding parameters and joint design were specifically developed to minimize mixing of the niobium with the U-6%Nb alloy. A Modified Faraday Cup (MFC) technique using computer-assisted tomography was employed to determine the precise power distribution of the electron beam so that the welding parameters could be directly transferred to other welding machines and/or to other facilities.

  3. Electron beam computed tomography (EBCT) funding protocol

    African Journals Online (AJOL)

    A funding protocol simply states the clinical indications for a particular procedure or treatment so that funders of ... The methodology used to develop a funding protocol is much shorter and simpler than that ... not a functional test (nuclear medicine stUdy or dobutamine echo), and therefore a positive test does not imply that ...

  4. Irradiation of wastewater with electron beam is a key to sustainable smart/green cities: a review

    Science.gov (United States)

    Hossain, Kaizar; Maruthi, Y. Avasn; Das, N. Lakshmana; Rawat, K. P.; Sarma, K. S. S.

    2018-03-01

    Remediation of wastewater, sludge and removal of objectionable substances from our environment using radiation technology is neglected. Hardly, a couple of decades ago, application of electron beam (EB) technology has gained attention for waste management. When wastewater is irradiated with electron beam, the beam can alter the physico-chemical properties of irradiated aqueous material and also transform wastewater chemicals due to the excitation or ionization of chemical molecules. Thus, chemical reactions may be capable of producing new compounds. The beam of electrons initiates primary reactions to induce the excitation or ionization of molecules at varied rates. This review paper will help to a budding researcher how to optimize the irradiation process to achieve high efficiency with low electron beam energy which is economically viable/feasible. Application of E-beam radiation for wastewater treatment may ensure future smart cities with sustainable water resources management.

  5. High throughput defect detection with multiple parallel electron beams

    NARCIS (Netherlands)

    Himbergen, H.M.P. van; Nijkerk, M.D.; Jager, P.W.H. de; Hosman, T.C.; Kruit, P.

    2007-01-01

    A new concept for high throughput defect detection with multiple parallel electron beams is described. As many as 30 000 beams can be placed on a footprint of a in.2, each beam having its own microcolumn and detection system without cross-talk. Based on the International Technology Roadmap for

  6. Microstructure evolution and fracture behaviour for electron beam ...

    Indian Academy of Sciences (India)

    The effect of microstructural characteristics on fracture behaviour mechanism for electron beam welding of Ti–6Al–4V was investigated. The results indicated that the welded microstructure composed of coarse needle + phases presenting disordered and multidirectional short needle morphology to make fracture ...

  7. Microstructure evolution and fracture behaviour for electron beam ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. The effect of microstructural characteristics on fracture behaviour mechanism for electron beam welding of Ti–6Al–4V was investigated. The results indicated that the welded microstructure composed of coarse needle α + β phases presenting disordered and multidirectional short needle morphology to make frac-.

  8. Sub-10 nm focused electron beam induced deposition

    NARCIS (Netherlands)

    Van Dorp, W.F.

    2008-01-01

    Work started with a critical review of literature from the past 70-odd years. The review shows that the physical processes occurring in EBID are generally well understood. By combining models for electron scattering in a solid and electron beam induced heating and knowledge of growth regimes, the

  9. Compact pulsed electron beam system for microwave generation

    Science.gov (United States)

    Sharma, S. K.; Deb, P.; Shukla, R.; Banerjee, P.; Prabaharan, T.; Adhikary, B.; Verma, R.; Sharma, A.; Shyam, A.

    2012-11-01

    A compact 180 kV electron beam system is designed for high power microwave generation. The electron beam system is consists of a secondary energy storage device, which can deliver energy to the load at faster rate than usual primary energy storage system such as tesla transformers or marx generator. The short duration, high voltage pulse with fast rise time and good flattop is applied to vacuum diode for high power microwave generation. The compact electron beam system is made up of single turn primary tesla transformer which charges a helical pulse forming line and transfers its energy to vacuum diode through a high voltage pressurized spark gap switch. We have used helical pulse forming line which has higher inductance as compared to coaxial pulse forming line, which in turns increases, the pulse width and reduce the length of the pulse forming line. Water dielectric medium is used because of its high dielectric constant, high dielectric strength and efficient energy storage capability. The time dependent breakdown property and high relative permittivity of water makes it an ideal choice for this system. The high voltage flat-top pulse of 90 kV, 260 ns is measured across the matched load. In this article we have reported the design details, simulation and initial experimental results of 180 kV pulsed electron beam system for high power microwave generation.

  10. Effect of electron beam irradiation on the structure and optical ...

    Indian Academy of Sciences (India)

    Abstract. This work reports the effect of electron beam (EB) irradiation on the structure and optical properties of nanocrystalline nickel oxide (NiO) cubes. NiO nanocubes were synthesized by the chemical precipitation method. The characterization was carried out by employing analytical techniques like X-ray diffraction, ...

  11. Planar electron beams in a wiggler magnet array

    Indian Academy of Sciences (India)

    2013-02-01

    Feb 1, 2013 ... Planar electron beams in a wiggler magnet array. ARTI HADAP1,∗ and K C MITTAL2. 1General Engineering Department, Terna Engineering College, Nerul, Navi Mumbai 400 706,. India. 2Accelerator and Pulsed Power Division, Bhabha Atomic Research Centre, Trombay,. Mumbai 400 085, India. ∗.

  12. Dielectronic recombination measurements at EBIT (Electron Beam Ion Trap)

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, D.A.

    1990-10-04

    The Electron Beam Ion Trap at the Lawrence Livermore National Laboratory has proved an ideal device for the study of interactions between electrons and highly-charged ions. I describe measurements of one such interaction, dielectronic recombination, in several ion species. The results are in marginal agreement with theoretical predictions. 8 refs., 6 figs.

  13. Electron beam computed tomography for the diagnosis of cardiac ...

    African Journals Online (AJOL)

    diagnosis of cardiac disease. Yadon Arad. Electron beam computed tomography (EBCT) of the heart is a new modality which will alter the way cardiology is practised. ... cardiovascular disease is either an acute myocardial infarction (MI) or ... Department of Preventive Cardiology, St Francis Hospital, Roslyn,. NY,USA.

  14. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    user

    2Radiation Technology Development Division, Bhabha Atomic Research Centre (BARC), Mumbai-400085, India. Accepted 30 May, 2011. The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of ...

  15. Molecule-by-Molecule Writing Using a Focused Electron Beam

    DEFF Research Database (Denmark)

    Van Dorp, Willem F.; Zhang, Xiaoyan; Feringa, Ben L.

    2012-01-01

    The resolution of lithography techniques needs to be extended beyond their current limits to continue the trend of miniaturization and enable new applications. But what is the ultimate spatial resolution? It is known that single atoms can be imaged with a highly focused electron beam. Can single ...

  16. Studies on tin oxide films prepared by electron beam evaporation ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Transparent conducting tin oxide thin films have been prepared by electron beam evaporation and spray pyrolysis methods. Structural, optical and electrical properties were studied under different pre- paration conditions like substrate temperature, solution flow rate and rate of deposition. Resistivity of un-.

  17. Studies on tin oxide films prepared by electron beam evaporation ...

    Indian Academy of Sciences (India)

    Transparent conducting tin oxide thin films have been prepared by electron beam evaporation and spray pyrolysis methods. Structural, optical and electrical properties were studied under different preparation conditions like substrate temperature, solution flow rate and rate of deposition. Resistivity of undoped evaporated ...

  18. Suppressor plate eliminates undesired arcing during electron beam welding

    Science.gov (United States)

    Hanchey, K. K.; Kubik, J.; Mahon, J. C.

    1966-01-01

    Suppressor grid eliminates undesired arcing during electron beam welding in one of two ways. A grid at ground potential collects secondary emission of ions and electrons produced by the beam as it strikes the workpiece, or a negatively energized grid repels the plasma arc back to the workpiece. This eliminates ground screens used to cover view ports.

  19. Microfissuring in Electron-Beam-Welded Nickel Alloy

    Science.gov (United States)

    Nunes, A. C., Jr

    1985-01-01

    Mathematical model developed for microfissuring of commercial nickel alloy during electron-beam welding. Number of measured microfissures per unit length of weld plotted against excess power calculated by computer model. Excess power that above level likely to produce microfissures. In agreement with model, measured microfissures increase at rate of 4.5 per inch (1.8 per centimeter) per excess kilowatt.

  20. Filler-wire positioner for electron beam welding

    Science.gov (United States)

    Beaupre, W. M.; Fueg, L. B.; Phillips, J. A.

    1970-01-01

    Miniaturized positioner is installed in any electron beam vacuum chamber for use with wire feed applications requiring filler wire. Horizontal and vertical control of the positioner is maintained from a console while chamber is under vacuum. Device permits more positive positioning of welding filler wire.

  1. Electron-beam deflection controlled by digital signals

    Science.gov (United States)

    Cressey, J. R.

    1965-01-01

    Electron-beam deflection in electronic image converters is controlled by a tapped magnetic deflection yoke and a series of current generators. The generators supply equal current to each tap through digitally controlled switches, thereby increasing the inherent accuracy of the system.

  2. A high brightness electron beam for Free Electron Lasers

    NARCIS (Netherlands)

    van Oerle, Bartholomeus Mathias; van Oerle, B.M.

    1997-01-01

    In a free electron laser, coherent radiation is generated by letting an electron beam propagate through an alternating magnetic field. The magnetic field is created by a linear array of magnets, which is called an undulator or a wiggler. The wavelength of the laser radiation depends on the amplitude

  3. Current understanding and issues on electron beam injection in space

    Science.gov (United States)

    Papadopoulos, K.; Szuszczewicz, E. P.

    1988-01-01

    The status of the physics understanding involved in electron beam injection in space is reviewed. The paper examines our understanding of beam plasma interactions and their associated wave and energized particle spectra of the processes involved in the beam plasma discharge, and of the vehicle charge neutralization. 'Strawman' models are presented for comparison with experimental observations.

  4. Two cavity autoacceleration of an intense relativistic electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, P.D.; Lockner, T.R.

    1985-01-01

    Two autoacceleration cavities have been used to accelerate an 11-kA electron beam from 2 MeV to approx. =2.8 MeV. The two 40-..cap omega.. cavities each accelerated the beam by approx. =400 kV with no observable interaction between the two cavities over several cavity transmit times. 6 figs.

  5. Proximity effect of electron beam lithography on single-electron ...

    Indian Academy of Sciences (India)

    monly used technique in this field, and many researchers have been investigating its application to make nanopatterns. In electron beam lithography, the well-known proximity effect refers to .... electrodes are grounded. The charging effect, which blocks the injection/ejection of a single charge into/from a quantum dot, ...

  6. Preparation of PbSe nanoparticles by electron beam irradiation ...

    Indian Academy of Sciences (India)

    Wintec

    Abstract. A novel method has been developed by electron beam irradiation to prepare PbSe nanoparticles. 2 MeV 10mA GJ-2-II electronic accelerator was used as radiation source. Nanocrystalline PbSe was prepared rapidly at room temperature under atmospheric pressure without any kind of toxic reagents. The structure.

  7. M11.4.1: Electron beam emittance meter finished

    CERN Document Server

    CORDE, S

    2011-01-01

    The method that we have successfully developed based on the X ray radiation emitted by betatronic motion of electrons in the plasma is reported here. We show here very preliminary experimental results that are very promising to determine in a single shot the electron beam emittance with a high resolution.

  8. PEPPo: Using a Polarized Electron Beam to Produce Polarized Positrons

    Energy Technology Data Exchange (ETDEWEB)

    Adeyemi, Adeleke H. [Hampton Univ., Hampton, VA (United States); et al.

    2015-09-01

    Polarized positron beams have been identified as either an essential or a significant ingredient for the experimental program of both the present and next generation of lepton accelerators (JLab, Super KEK B, ILC, CLIC). An experiment demonstrating a new method for producing polarized positrons has been performed at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. The PEPPo (Polarized Electrons for Polarized Positrons) concept relies on the production of polarized e⁻/e⁺ pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. PEPPo demonstrated the effective transfer of spin-polarization of an 8.2 MeV/c polarized (P~85%) electron beam to positrons produced in varying thickness tungsten production targets, and collected and measured in the range of 3.1 to 6.2 MeV/c. In comparison to other methods this technique reveals a new pathway for producing either high-energy or thermal polarized positron beams using a relatively low polarized electron beam energy (~10MeV) .This presentation will describe the PEPPo concept, the motivations of the experiment and high positron polarization achieved.

  9. Attainment of Electron Beam Suitable for Medium Energy Electron Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Seletskiy, Sergei M. [Univ. of Rochester, NY (United States)

    2005-01-01

    Electron cooling of charged particle beams is a well-established technique at electron energies of up to 300 keV. However, up to the present time the advance of electron cooling to the MeV-range energies has remained a purely theoretical possibility. The electron cooling project at Fermilab has recently demonstrated the ¯rst cooling of 8.9 GeV/c antiprotons in the Recycler ring, and therefore, has proved the validity of the idea of relativistic electron cool- ing. The Recycler Electron Cooler (REC) is the key component of the Teva- tron Run II luminosity upgrade project. Its performance depends critically on the quality of electron beam. A stable electron beam of 4.3 MeV car- rying 0.5 A of DC current is required. The beam suitable for the Recycler Electron Cooler must have an angular spread not exceeding 200 ¹rad. The full-scale prototype of the REC was designed, built and tested at Fermilab in the Wideband laboratory to study the feasibility of attaining the high-quality electron beam. In this thesis I describe various aspects of development of the Fermilab electron cooling system, and the techniques used to obtain the electron beam suitable for the cooling process. In particular I emphasize those aspects of the work for which I was principally responsible.

  10. Size Control Technology of Silver Nanoparticles Using Electron Beam Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Suk; Kim, Byungnam; Kim, Hye Won; Koo, Yong Hwan; Lee, Byung Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Ji Hyun [Univ. of Science and Technology, Daejeon (Korea, Republic of); Bae, Hyung Bin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Changmoon [Chungnam National Univ., Daejeon (Korea, Republic of)

    2013-12-15

    The manufacturing of silver nanoparticles using an electron beam is easy, fast, and highly productive, and it is possible at room temperature with no chemical residuals. Its various advantages therefore make this an important method for manufacturing nanoparticles such as silver, copper, and platinum. In particular, despite the use of electron beam irradiation, the results show that this method makes it possible to produce silver nanoparticles at low cost since low beam energy and low doses are used. This means that middle and high-energy electron beam accelerators are very expensive, but a low-energy electron beam accelerator has a relatively low cost of around 4-5 times, and mass production for a flow reaction without the need for extra radiation shielding is possible. Silver nanoparticles are of great interest to many researchers owing to their ability to be used in many applications such as catalysis, nanoelectronics, optical filters, electromagnetic interference shielding, surface Raman scattering, medical supplies, fabrics, cosmetics, hygiene and kitchen supplies, and electric home appliances.

  11. Electron Beam Cured Epoxy Resin Composites for High Temperature Applications

    Science.gov (United States)

    Janke, Christopher J.; Dorsey, George F.; Havens, Stephen J.; Lopata, Vincent J.; Meador, Michael A.

    1997-01-01

    Electron beam curing of Polymer Matrix Composites (PMC's) is a nonthermal, nonautoclave curing process that has been demonstrated to be a cost effective and advantageous alternative to conventional thermal curing. Advantages of electron beam curing include: reduced manufacturing costs; significantly reduced curing times; improvements in part quality and performance; reduced environmental and health concerns; and improvement in material handling. In 1994 a Cooperative Research and Development Agreement (CRADA), sponsored by the Department of Energy Defense Programs and 10 industrial partners, was established to advance the electron beam curing of PMC technology. Over the last several years a significant amount of effort within the CRADA has been devoted to the development and optimization of resin systems and PMCs that match the performance of thermal cured composites. This highly successful materials development effort has resulted in a board family of high performance, electron beam curable cationic epoxy resin systems possessing a wide range of excellent processing and property profiles. Hundreds of resin systems, both toughened and untoughened, offering unlimited formulation and processing flexibility have been developed and evaluated in the CRADA program.

  12. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.

    Science.gov (United States)

    Gerbi, Bruce J; Antolak, John A; Deibel, F Christopher; Followill, David S; Herman, Michael G; Higgins, Patrick D; Huq, M Saiful; Mihailidis, Dimitris N; Yorke, Ellen D; Hogstrom, Kenneth R; Khan, Faiz M

    2009-07-01

    The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of.Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance testing and treatment planning of new accelerators with therapeutic electron beams. Since the publication of the TG-25 report, significant advances have taken place in the field of electron beam dosimetry, the most significant being that primary standards laboratories around the world have shifted from calibration standards based on exposure or air kerma to standards based on absorbed dose to water. The AAPM has published a new calibration protocol, TG-51, for the calibration of high-energy photon and electron beams. The formalism and dosimetry procedures recommended in this protocol are based on the absorbed dose to water calibration coefficient of an ionization chamber at 60Co energy, N60Co(D,w), together with the theoretical beam quality conversion coefficient k(Q) for the determination of absorbed dose to water in high-energy photon and electron beams. Task Group 70 was charged to reassess and update the recommendations in TG-25 to bring them into alignment with report TG-51 and to recommend new methodologies and procedures that would allow the practicing medical physicist to initiate and continue a high quality program in clinical electron beam dosimetry. This TG-70 report is a supplement to the TG-25 report and enhances the TG-25 report by including new topics and topics that were not covered in depth in the TG-25 report. These topics include procedures for obtaining data to commission a treatment planning computer, determining dose in irregularly shaped electron fields, and commissioning of sophisticated special procedures using high-energy electron beams. The use of

  13. Energy Spread Reduction of Electron Beams Produced via Laser Wake

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, Bradley Bolt [Univ. of California, San Diego, CA (United States)

    2012-01-01

    Laser wakefield acceleration of electrons holds great promise for producing ultra-compact stages of GeV scale, high quality electron beams for applications such as x-ray free electron lasers and high energy colliders. Ultra-high intensity laser pulses can be self-guided by relativistic plasma waves over tens of vacuum diffraction lengths, to give >1 GeV energy in cm-scale low density plasma using ionization-induced injection to inject charge into the wake at low densities. This thesis describes a series of experiments which investigates the physics of LWFA in the self-guided blowout regime. Beginning with high density gas jet experiments the scaling of the LWFA-produced electron beam energy with plasma electron density is found to be in excellent agreement with both phenomenological theory and with 3-D PIC simulations. It is also determined that self-trapping of background electrons into the wake exhibits a threshold as a function of the electron density, and at the densities required to produce electron beams with energies exceeding 1 GeV a different mechanism is required to trap charge into low density wakes. By introducing small concentrations of high-Z gas to the nominal He background the ionization-induced injection mechanism is enabled. Electron trapping is observed at densities as low as 1.3 x 1018 cm-3 in a gas cell target, and 1.45 GeV electrons are demonstrated for the first time from LWFA. This is currently the highest electron energy ever produced from LWFA. The ionization-induced trapping mechanism is also shown to generate quasi-continuous electron beam energies, which is undesirable for accelerator applications. By limiting the region over which ionization-induced trapping occurs, the energy spread of the electron beams can be controlled. The development of a novel two-stage gas cell target provides the capability to tailor the gas composition in the longitudinal direction, and confine the trapping process to occur only in a

  14. Effect of electron beam-irradiation to b-glucan on its immunomodulating and antitumor activity

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yeon Hwan; Lee, Jung Lim; Yoo, Yung Choon [Konyand Univ., Daejeon (Korea, Republic of); Kim, Jae Hoon; Lee, Ju Woon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-07-01

    In this study, in order investigated the effect of electron beam irradiation to b-glucan on its biological activities, we compared immunomodulating and antitumor activity between non-irradiated and electron beam-irradiated b-glucan. EB-glucan was irradiated by electron beam with 10, 30 and 50 kGy. Treatment with EB-glucan resulted in a slight increase of the proliferation of ConA-stimulated splenocytes, and the strongest activity was seen in 50 kGy-treated EB-glucan. EB-glucan teated with 50 kGy also showed increased secretion of cytokines such as IL-2 IFN-{gamma} and IL-6 from ConA-stimulated splenocytes. The activity of EB-glucan to enhance the proliferation of splenocytes and cytokine secretion from ConA-stimulated splenocytes was higher than that of NI-glucan. Furthermore, EB-glucan treated with 50 kGy showed higher activity to activate RAW 264.7 macrophages, comparing with that of NI-glucan. In experiments of antitumor activity, EB-glucan treated with 50 kGy prior to tumor inoculation inhibited an experimental lung metastasis produced by B16-BL6 melanoma cells in mice. But NI-glucan did show no effect. In addition, EB-glucan treated with 50 kGy induced a decrease a decrease of tumor growth in tumor-bearing mice. Collectivelt, these results indicates that electron beam irradiation {beta}-glucan leads its biological functions to enhance immunomodulating and antitumor activity.

  15. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams

    Science.gov (United States)

    Chow, James C. L.; Jiang, Runqing

    2012-06-01

    This study examines variations of bone and mucosal doses with variable soft tissue and bone thicknesses, mimicking the oral or nasal cavity in skin radiation therapy. Monte Carlo simulations (EGSnrc-based codes) using the clinical kilovoltage (kVp) photon and megavoltage (MeV) electron beams, and the pencil-beam algorithm (Pinnacle3 treatment planning system) using the MeV electron beams were performed in dose calculations. Phase-space files for the 105 and 220 kVp beams (Gulmay D3225 x-ray machine), and the 4 and 6 MeV electron beams (Varian 21 EX linear accelerator) with a field size of 5 cm diameter were generated using the BEAMnrc code, and verified using measurements. Inhomogeneous phantoms containing uniform water, bone and air layers were irradiated by the kVp photon and MeV electron beams. Relative depth, bone and mucosal doses were calculated for the uniform water and bone layers which were varied in thickness in the ranges of 0.5-2 cm and 0.2-1 cm. A uniform water layer of bolus with thickness equal to the depth of maximum dose (dmax) of the electron beams (0.7 cm for 4 MeV and 1.5 cm for 6 MeV) was added on top of the phantom to ensure that the maximum dose was at the phantom surface. From our Monte Carlo results, the 4 and 6 MeV electron beams were found to produce insignificant bone and mucosal dose (oral or nasal cavity. While the dose distribution in the pharynx region is unavailable due to the lack of a commercial treatment planning system commissioned for kVp beam planning in skin radiation therapy, our study provided an essential insight into the radiation staff to justify and estimate bone and mucosal dose.

  16. The effect of electron beam irradiation on lipid oxidation in sausages

    Directory of Open Access Journals (Sweden)

    atefeh yousefi

    2017-09-01

    Full Text Available Introduction: Irradiation treatment is one of the best techniques to extend the shelf-life of meat, without emerging the nutritional properties and sensory quality of irradiated meat products.  However electron -beam  may cause transformations in foods but has been known as to the most easily-applied irradiation technique in food industries. Electron-beam irradiation is an environment friendly, low cost and time effective alternative to other decontamination technologies. Lipid oxidation could produce of irradiated meat. This study aimed at evaluating the state of lipid oxidation of irradiated sausages. Its findings could help the control, improve food safety and quality properties to food industries. Methods: Sausages were purchased in a local supermarket, minced sausages blended for thiobarbituric acid reactive substances (TBARS analysis and divided into 25 g pieces. The samples including one control group and four case groups. Packaged sausage were exposed at doses of 0 (control, 1, 2, 3 and 5 kGy and analyzed on various days 0, 5, 10 and 30. Results: Thiobarbituric acid reactive substances (TBARS has increased as time goes on (P<0.05. A significant relationship was observed on different Doses. But, the maximum of TBARS was observed in 3 kGy. Conclusion: Utilizing of Electron-beam irradiation in low doses does not have significant difference on lipid oxidation. Irradiating of meat products by addition of antioxidants can minimize or avoid the development of rancidity.

  17. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years]) with histopatholog......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...... causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration...

  18. CRADA Final Report for CRADA No. ORNL99-0544, Interfacial Properties of Electron Beam Cured Composites

    Energy Technology Data Exchange (ETDEWEB)

    Janke, C.J.

    2005-10-17

    manage the large project team and properly address the various technical tasks, the CRADA team was organized into integrated project teams (IPT's) with each team focused on specific research areas. Early in the project, the end user partners developed ''exit criteria'', recorded in Appendix B, against which the project's success was to be judged. The project team made several important discoveries. A number of fiber coatings or treatments were developed that improved fiber-matrix adhesion by 40% or more, according to microdebond testing. The effects of dose-time and temperature-time profiles during the cure were investigated, and it was determined that fiber-matrix adhesion is relatively insensitive to the irradiation procedure, but can be elevated appreciably by thermal postcuring. Electron beam curable resin properties were improved substantially, with 80% increase in electron beam 798 resin toughness, and {approx}25% and 50% improvement, respectively, in ultimate tensile strength and ultimate tensile strain vs. earlier generation electron beam curable resins. Additionally, a new resin electron beam 800E was developed with generally good properties, and a very notable 120% improvement in transverse composite tensile strength vs. earlier generation electron beam cured carbon fiber reinforced epoxies. Chemical kinetics studies showed that reaction pathways can be affected by the irradiation parameters, although no consequential effects on material properties have been noted to date. Preliminary thermal kinetics models were developed to predict degree of cure vs. irradiation and thermal parameters. These models are continually being refined and validated. Despite the aforementioned impressive accomplishments, the project team did not fully realize the project objectives. The best methods for improving adhesion were combined with the improved electron beam 3K resin to make prepreg and uni-directional test laminates from which composite

  19. Formation of Surface Nano- and Textured Austenite Induced by Pulsed Electron Beam Irradiation under Melting Mode

    Directory of Open Access Journals (Sweden)

    K. M. Zhang

    2013-01-01

    Full Text Available We report in this paper an interesting phenomenon associated with low-energy high-current pulsed electron beam (LEHCPEB treatment: surface nanograined and textured austenite formation under the melting treatment mode. The treatment induces superfast heating and melting followed by a rapid solidification and cooling of the material surfaces. As a result, nano-structured surface layers can be achieved quite easily. Examples of nanoaustenite formation with special texture state in the modified surface layer of AISI D2 steel and NiTi alloy will show the potential for surface nanocrystallization of materials with improved properties by LEHCPEB technique.

  20. Creation, Transport and Measurement of Bright Relativistic Electron Beams.

    Science.gov (United States)

    McKee, Chad Bennett

    This thesis deals with three topics relevant to linac-driven free electron lasers: the creation, transport and measurement of bright relativistic electron beams. Thermionic microwave electron guns produce bright electron beams that are well suited to drive free electron lasers, FELs. The rf fields in the gun cause some of the emitted electrons to reverse direction and strike the cathode. These back-bombarding electrons heat the cathode limiting both the pulse length and time averaged current. The cathode heating is reduced if a transverse magnetic field is applied across the gun cavity to deflect back-bombarding electrons. We improve the thermionic microwave electron gun by redesigning the deflection magnet to minimize the back-heating power. Computer simulations show that transverse magnetic fields with rapid axial falloffs reduce the back-heating power more than fields that are axially constant. Experiments verify these simulations. The deflection magnet presently installed on the Mark III gun has a slow axial falloff and reduces the back-heating power by 31%. Using the simulation results we design a new deflection magnet having a rapid axial falloff. This magnet has been installed on the NCCU gun and reduces the back-heating power by 63%. Improper transport of the electron beam through the beam line degrades the quality of the electron beam and lowers the performance of the FEL. We propose to improve the beam line commissioning and control procedures on linac -driven FELs by experimentally measuring the transfer matrix of each beam line section. The transfer matrix of a given section is measured by dithering the electron beam, measuring the beam vector before and after the section and inverting the subsequent data matrix. We minimize the beam line errors by minimizing the deviation between the experimentally measured transfer matrix and the design transfer matrix of each beam line section. While not experimentally verified, computer simulations show that this

  1. The investigation of ultrasonic mechanical forging influence on the structure and mechanical properties of VT23 welded joints by methods of laser and electron beam welding

    Science.gov (United States)

    Smirnova, A. S.; Pochivalov, Yu. I.; Panin, V. E.; Orishich, A. M.; Malikov, A. G.; Fomin, V. M.

    2016-11-01

    The structure and mechanical properties of welded joints of VT23 titanium alloy received by methods of laser and electron beam welding with subsequent thermomechanical treatment (TMP1 and TMP2) including ultrasonic mechanical forging are investigated. X-ray structure analysis, scanning electron and transmission electron microscopy have revealed the features of phase structure, microstructure and fractography of welded joints after electron beam and laser welding with subsequent ultrasonic mechanical forging. Application of ultrasonic mechanical forging of welded joints produced by electron beam and laser welding has allowed increasing fatigue life of samples of welded joints after laser welding from 6369 to 19 569 cycles and from 54 616 cycles to 77 126 cycles for electron beam welding. Thus, the application of ultrasonic mechanical forging can significantly raise fatigue and mechanical characteristics of welded connections.

  2. Electron beam welding of copper-Monel facilitated by circular magnetic shields

    Science.gov (United States)

    Lamb, J. N.

    1966-01-01

    High permeability, soft magnetic rings are placed on both sides of electron beam weld seams in copper-Monel circular joint. This eliminates deflection of the electron beam caused by magnetic fields present in the weld area.

  3. Numerical simulation of electron beam welding with beam oscillations

    Science.gov (United States)

    Trushnikov, D. N.; Permyakov, G. L.

    2017-02-01

    This research examines the process of electron-beam welding in a keyhole mode with the use of beam oscillations. We study the impact of various beam oscillations and their parameters on the shape of the keyhole, the flow of heat and mass transfer processes and weld parameters to develop methodological recommendations. A numerical three-dimensional mathematical model of electron beam welding is presented. The model was developed on the basis of a heat conduction equation and a Navier-Stokes equation taking into account phase transitions at the interface of a solid and liquid phase and thermocapillary convection (Marangoni effect). The shape of the keyhole is determined based on experimental data on the parameters of the secondary signal by using the method of a synchronous accumulation. Calculations of thermal and hydrodynamic processes were carried out based on a computer cluster, using a simulation package COMSOL Multiphysics.

  4. Electron beam welding of iridium heat source capsules

    Science.gov (United States)

    Mustaleski, Thomas M.; Yearwood, J. Cecil; Burgan, Clyde E.; Green, L. A.

    1991-01-01

    The development of the welding procedures for the production of DOP-26 iridium alloy cups for heat source encapsulation is described. All the final assembly welds were made using the electron beam welding process. The welding of the 0.13-mm weld shield required the use of computer controlled X-Y table and a run-off tab. Welding of the frit vent to the cup required that a laser weld be made to hold the frit assembly edges together for the final electron beam weld. Great care is required in tooling design and beam placement to achieve acceptable results. Unsuccessful attempts to use laser beam welding for heat shield butt weld are discussed.

  5. Electrostatic charging of spacecraft in response to electron beam injection

    Science.gov (United States)

    Singh, Nagendra; Hwang, K. S.

    1989-01-01

    Electron beam injections from spacecraft now constitute a major activity in space research. Here, the charging level of a conducting surface when an electron beam is injected from it is investigated. Injections into both vacuum and an ambient plasma are considered. When a Maxwellian beam is injected into vacuum, the surface changes to a potential much greater than the average beam energy. The dependence of this excess is examined by considering beams with water-bag types of velocity distribution functions in which no electron has a velocity V(max) above a certain value. The electric field distribution in the electron sheath near the surface is determined by the pressure distribution. Thus, the surface potential is determined not only by V(max) but by all the beam parameters. The ambient plasma reduces the charging level and causes an oscillation in the surface potential. The oscillation frequency is the electron-plasma frequency associated with the ambient plasma.

  6. Nanostructure fabrication using electron beam irradiation of organometallic compounds

    CERN Document Server

    Bedson, T R

    2001-01-01

    Nanoelectronics- the quest to fabricate quantum devices- is the motivation for this thesis. The place of nanolithography is discussed amongst conventional microfabrication methods, together with the materials currently employed in lithography. The experimental methods, equipment and new resist materials (films of nanoparticles) are then explored in the work described. A summary of the results obtained by the research is presented, followed by the detailed results in the form of a series of published and submitted papers. A systematic study of the response of ferrocene adsorbed onto graphite at 160K to low energy electron beams, that results in varying behaviour depending on the energy of irradiation, is first described. Following are studies of the characteristics of passivated gold nanoclusters when used as a monolayer negative tone resist in direct electron beam writing. Fabrication of lines with widths as narrow as 26 nm has been achieved. Measurements of the linewidth as a function of electron dose allow ...

  7. The effective synthesis of Insoluble sulfur using electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Daejin; Yu, Kookhyun [Dongguk Univ., Seoul (Korea, Republic of)

    2013-07-01

    Vulcanization is process that formed crosslinking by Insoluble sulfur between linear structure of rubber polymer. Recently, Synthesis of Insoluble sulfur is used Thermal polymerization using about 250 {approx} 300 .deg. C and extraction process is used carbon disulfide(CS2) for separation between soluble sulfur and insoluble sulfur. But this process isn't environmental, economical and safety. This research was focus on developing of insoluble sulfur synthesis process using electron beam. This new process is using under the 140 .deg. C. Because of that, explosion risk is decrease, environmental and economical factor is increased. The sulfur can be melt by increase temperature or made solution using carbon disulfide. And electron beam is irradiated melting sulfur or sulfur solution. After irradiation, The high purity insoluble sulfur can be obtained by separation with carbon disulfide.

  8. Electron Beam Energy Compensation by Controlling RF Pulse Shape

    CERN Document Server

    Kii, T; Kusukame, K; Masuda, K; Nakai, Y; Ohgaki, H; Yamazaki, T; Yoshikawa, K; Zen, H

    2005-01-01

    We have studied on improvement of electron beam macropulse properties from a thermionic RF gun. Though a thermionic RF gun has many salient features, there is a serious problem that back-bombardment effect worsens quality of the beam. To reduce beam energy degradation by this effect, we tried to feed non-flat RF power into the gun. As a result, we successfully obtained about 1.5 times longer macropulse and two times larger total charge per macropulse. On the other hand, we calculated transient evolution of RF power considering non-constant beam loading. The beam loading is evaluated from time evolution of cathode temperature, by use of one dimensional heat conduction model and electron trajectories' calculations by a particle simulation code. Then we found good agreement between the experimental and calculation results. Furthermore, with the same way, we studied the electron beam output dependence on the cathode radius.

  9. High current nonlinear transmission line based electron beam driver

    Science.gov (United States)

    Hoff, B. W.; French, D. M.; Simon, D. S.; Lepell, P. D.; Montoya, T.; Heidger, S. L.

    2017-10-01

    A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage).

  10. Spodumene and garnet luminescence excited by subnanosecond electron beams

    Science.gov (United States)

    Baksht, E. Kh.; Burachenko, A. G.; Solomonov, V. I.; Tarasenko, V. F.

    2011-11-01

    Pulsed cathodoluminescence of spodumene and yttrium-aluminum garnet crystals activated by Mn2+ and Nd3+ ions, respectively, is investigated. The luminescence was excited upon crystal irradiation by electron beams with current densities of 35 and 100 A/cm2 and average electron energy of ˜ 50 keV for 0.1, 0.25, and 0.65 ns. It is demonstrated that the electron beam duration decreased to several tenth of a nanosecond does not lead to essential changes of the mechanisms of pulsed cathodoluminescence excitation and character of its spectrum, but in this case, the intensity of luminescence of the hole centers increases compared with the intracenter luminescence.

  11. In situ electron-beam polymerization stabilized quantum dot micelles.

    Science.gov (United States)

    Travert-Branger, Nathalie; Dubois, Fabien; Renault, Jean-Philippe; Pin, Serge; Mahler, Benoit; Gravel, Edmond; Dubertret, Benoit; Doris, Eric

    2011-04-19

    A polymerizable amphiphile polymer containing PEG was synthesized and used to encapsulate quantum dots in micelles. The quantum dot micelles were then polymerized using a "clean" electron beam process that did not require any post-irradiation purification. Fluorescence spectroscopy revealed that the polymerized micelles provided an organic coating that preserved the quantum dot fluorescence better than nonpolymerized micelles, even under harsh conditions. © 2011 American Chemical Society

  12. Radial electron-beam-breakup transit-time oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Mostrom, M.A. [Mission Research Corp., Albuquerque, NM (United States); Kwan, T.J.T. [Los Alamos National Lab., NM (United States)

    1995-01-01

    A new radially-driven electron-beam-breakup transit-time oscillator has been investigated analytically and through computer simulation as a compact low-impedance high-power microwave generator. In a 1MV, 50kA device 35cm in radius and 15cm long, with no external magnetic field, 5GW of extracted power and a growth rate of 0.26/ns have been observed. Theoretical maximum efficiencies are several times higher.

  13. Beam distribution reconstruction simulation for electron beam probe

    Science.gov (United States)

    Feng, Yong-Chun; Mao, Rui-Shi; Li, Peng; Kang, Xin-Cai; Yin, Yan; Liu, Tong; You, Yao-Yao; Chen, Yu-Cong; Zhao, Tie-Cheng; Xu, Zhi-Guo; Wang, Yan-Yu; Yuan, You-Jin

    2017-07-01

    An electron beam probe (EBP) is a detector which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While it can be applied to many aspects, we limit our analysis to beam distribution reconstruction. This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment. In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain a parallel electron beam is introduced and a simulation code is developed. An EBP as a profile monitor for dense beams is then simulated using the fast scan method for various target beam profiles, including KV distribution, waterbag distribution, parabolic distribution, Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory is implemented and compared with the actual profile, and the expected agreement is achieved. Furthermore, as well as fast scan, a slow scan, i.e. step-by-step scan, is considered, which lowers the requirement for hardware, i.e. Radio Frequency deflector. We calculate the three-dimensional electric field of a Gaussian distribution and simulate the electron motion in this field. In addition, a fast scan along the target beam direction and slow scan across the beam are also presented, and can provide a measurement of longitudinal distribution as well as transverse profile simultaneously. As an example, simulation results for the China Accelerator Driven Sub-critical System (CADS) and High Intensity Heavy Ion Accelerator Facility (HIAF) are given. Finally, a potential system design for an EBP is described.

  14. Structured electron beams from nano-engineered cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Lueangaramwong, A. [NICADD, DeKalb; Mihalcea, D. [NICADD, DeKalb; Andonian, G. [RadiaBeam Tech.; Piot, P. [Fermilab

    2017-03-07

    The ability to engineer cathodes at the nano-scale have open new possibilities such as enhancing quantum eciency via surface-plasmon excitation, forming ultra-low-emittance beams, or producing structured electron beams. In this paper we present numerical investigations of the beam dynamics associated to this class of cathode in the weak- and strong-field regimes.We finally discuss the possible applications of some of the achievable cathode patterns when coupled with other phase space manipulations.

  15. Industrial applications of electron beam; Przemyslowe zastosowamia wiazki elektronow

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A.G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    The review of industrial applications with use of electron beams has been done. Especially the radiation technologies being developed in Poland have been shown. Industrial installations with electron accelerators as radiation source have been applied for: modification of polymers; modification of thyristors; sterilization of health care materials; radiopreservation of food and other consumer products; purification of combustion flue gases in heat and power plants. 14 refs, 6 tabs, 7 figs.

  16. Hydrogels Synthesized by Electron Beam Irradiation for Heavy Metal Adsorption

    OpenAIRE

    Elena Manaila; Gabriela Craciun; Daniel Ighigeanu; Catalina Cimpeanu; Catalina Barna; Viorel Fugaru

    2017-01-01

    Poly(acrylamide co-acrylic acid) hydrogels were prepared by free-radical copolymerization of acrylamide and acrylic acid in aqueous solutions using electron beam irradiation in the dose range of 2.5 kGy to 6 kGy in atmospheric conditions and at room temperature. The influence of the absorbed dose, the amount of cross-linker (trimethylolpropane trimethacrylate) and initiator (potassium persulfate) on the swelling properties and the diffusion coefficient and network parameters of hydrogels were...

  17. Electron Beam Welding to Join Gamma Titanium Aluminide Articles

    Science.gov (United States)

    Kelly, Thomas Joseph (Inventor)

    2008-01-01

    A method is provided for welding two gamma titanium aluminide articles together. The method includes preheating the two articles to a welding temperature of from about 1700 F to about 2100 F, thereafter electron beam welding the two articles together at the welding temperature and in a welding vacuum to form a welded structure, and thereafter annealing the welded structure at an annealing temperature of from about 1800 F to about 2200 F, to form a joined structure.

  18. Weld formation control at electron beam welding with beam oscillations

    OpenAIRE

    Trushnikov, Dmitriy; Koleva, Elena; Mladenov, Georgy; A. Shcherbakov

    2014-01-01

    Electron beam welding is used extensively to produce essential machine parts. The control of the basic beam parameters beam power or beam current at constant accelerating voltage, welding speed, current of focusing lens and distance between electron gun and welded sample surface is not enough to obtain at most of the regimes sound welds. Control of the focus position using analysis of the high frequency component of the current, collected by plasma, at periodic interactions on the beam (the o...

  19. Electron-beam driven relaxation oscillations in ferroelectric nanodisks

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Nathaniel; Ahluwalia, Rajeev [Institute of High Performance Computing, Singapore 138632 (Singapore); Kumar, Ashok [CSIR-National Physical Laboratory, Delhi 110012 (India); Srolovitz, David J. [Department of Materials Science and Engineering and Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Chandra, Premala [Department of Physics and Astronomy, Center for Materials Theory, Rutgers University, Piscataway, New Jersey 08854 (United States); Scott, James F. [Department of Physics, Cavendish Laboratory, J. J. Thompson Avenue, Cambridge CB3 0HE (United Kingdom); Department of Chemistry and Department of Physics, University of St. Andrews, St. Andrews YX16 9ST (United Kingdom)

    2015-10-12

    Using a combination of computational simulations, atomic-scale resolution imaging and phenomenological modelling, we examine the underlying mechanism for nanodomain restructuring in lead zirconate titanate nanodisks driven by electron beams. The observed subhertz nanodomain dynamics are identified with relaxation oscillations where the charging/discharging cycle time is determined by saturation of charge traps and nanodomain wall creep. These results are unusual in that they indicate very slow athermal dynamics in nanoscale systems, and possible applications of gated versions are discussed.

  20. Electron beam, laser beam and plasma arc welding studies

    Science.gov (United States)

    Banas, C. M.

    1974-01-01

    This program was undertaken as an initial step in establishing an evaluation framework which would permit a priori selection of advanced welding processes for specific applications. To this end, a direct comparison of laser beam, electron beam and arc welding of Ti-6Al-4V alloy was undertaken. Ti-6Al-4V was selected for use in view of its established welding characteristics and its importance in aerospace applications.

  1. Unveiling the orbital angular momentum and acceleration of electron beams.

    Science.gov (United States)

    Shiloh, Roy; Tsur, Yuval; Remez, Roei; Lereah, Yossi; Malomed, Boris A; Shvedov, Vladlen; Hnatovsky, Cyril; Krolikowski, Wieslaw; Arie, Ady

    2015-03-06

    New forms of electron beams have been intensively investigated recently, including vortex beams carrying orbital angular momentum, as well as Airy beams propagating along a parabolic trajectory. Their traits may be harnessed for applications in materials science, electron microscopy, and interferometry, and so it is important to measure their properties with ease. Here, we show how one may immediately quantify these beams' parameters without need for additional fabrication or nonstandard microscopic tools. Our experimental results are backed by numerical simulations and analytic derivation.

  2. Electron Beam Collimation for the Next Generation Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Steier, C.; Emma, P.; Nishimura, H.; Papadopoulos, C.; Sannibale, F.

    2013-05-20

    The Next Generation Light Source will deliver high (MHz) repetition rate electron beams to an array of free electron lasers. Because of the significant average current in such a facility, effective beam collimation is extremely important to minimize radiation damage to undulators, prevent quenches of superconducting cavities, limit dose rates outside of the accelerator tunnel and prevent equipment damage. This paper describes the early conceptual design of a collimation system, as well as initial results of simulations to test its effectiveness.

  3. Resist requirements and limitations for nanoscale electron-beam patterning.

    Energy Technology Data Exchange (ETDEWEB)

    Liddle, J. A.; Gallatin, G. M.; Ocola, L. E.; Experimental Facilities Division (APS); LBNL; IBM T.J. Watson Research Center

    2003-01-01

    Electron beam lithography still represents the most effective way to pattern materials at the nanoscale, especially in the case of structures, which are not indefinitely repeating a simple motif. The success of e-beam lithography depends on the availability of suitable resists. There is a substantial variety of resist materials, from PMMA to calixarenes, to choose from to achieve high resolution in electron-beam lithography. However, these materials suffer from the limitation of poor sensitivity and poor contrast. In both direct-write and projection e-beam systems the maximum beam current for a given resolution is limited by space-charge effects. In order to make the most efficient use of the available current, the resist must be as sensitive as possible. This leads, naturally, to the use of chemically amplified (CA) systems. Unfortunately, in the quest for ever smaller feature sizes and higher throughputs, even chemically amplified materials are limited: ultimately, sensitivity and resolution are not independent. Current resists already operate in the regime of < 1 electron/nm2. In this situation detailed models are the only way to understand material performance and limits. Resist requirements, including sensitivity, etch selectivity, environmental stability, outgassing, and line-edge roughness as they pertain to, high-voltage (100 kV) direct write and projection electron-beam exposure systems are described. Experimental results obtained on CA resists in the SCALPEL exposure system are presented and the fundamental sensitivity limits of CA and conventional materials in terms of shot-noise and resolution limits in terms of electron-beam solid interactions are discussed.

  4. Bulk Cutting of Carbon Nanotubes Using Electron Beam Irradiation

    Science.gov (United States)

    Ziegler, Kirk J. (Inventor); Rauwald, Urs (Inventor); Hauge, Robert H. (Inventor); Schmidt, Howard K. (Inventor); Smalley, Richard E. (Inventor); Kittrell, W. Carter (Inventor); Gu, Zhenning (Inventor)

    2013-01-01

    According to some embodiments, the present invention provides a method for attaining short carbon nanotubes utilizing electron beam irradiation, for example, of a carbon nanotube sample. The sample may be pretreated, for example by oxonation. The pretreatment may introduce defects to the sidewalls of the nanotubes. The method is shown to produces nanotubes with a distribution of lengths, with the majority of lengths shorter than 100 tun. Further, the median length of the nanotubes is between about 20 nm and about 100 nm.

  5. Space-charge dynamics of polymethylmethacrylate under electron beam irradiation

    CERN Document Server

    Gong, H; Ong, C K

    1997-01-01

    Space-charge dynamics of polymethylmethacrylate (PMMA) under electron beam irradiation has been investigated employing a scanning electron microscope. Assuming a Gaussian space-charge distribution, the distribution range (sigma) has been determined using a time-resolved current method in conjunction with a mirror image method. sigma is found to increase with irradiation time and eventually attain a stationary value. These observations have been discussed by taking into account radiation-induced conductivity and charge mobility. (author)

  6. Small field electron beam dosimetry using MOSFET detector.

    Science.gov (United States)

    Amin, Md Nurul; Heaton, Robert; Norrlinger, Bern; Islam, Mohammad K

    2010-10-04

    The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becoming filmless in favor of electronic imaging, an alternate and readily available clinical dosimeter needs to be explored. We have studied the performance of MOSFET as a relative dosimeter in small field electron beams. The reproducibility, linearity and sensitivity of a high-sensitivity microMOSFET were investigated for clinical electron beams. In addition, the percent depth doses, output factors and profiles have been measured in a water tank with MOSFET and compared with those measured by an ion chamber for a range of field sizes from 1 cm diameter to 10 cm × 10 cm for 6, 12, 16 and 20 MeV beams. Similar comparative measurements were also per-formed with MOSFET and films in solid water phantom. The MOSFET sensitivity was found to be practically constant over the range of field sizes investigated. The dose response was found to be linear and reproducible (within ± 1% for 100 cGy). An excellent agreement was observed among the central axis depth dose curves measured using MOSFET, film and ion chamber. The output factors measured with MOSFET for small fields agreed to within 3% with those measured by film dosimetry. Overall results indicate that MOSFET can be utilized to perform dosimetry for small field electron beam.

  7. Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation

    OpenAIRE

    Valeriy Shchavlev; Anatoliy Piskunov; Aleksandr Abdullin; Vladimir Belenkiy; Georgy Mladenov; Dmitriy Trushnikov

    2012-01-01

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which sub...

  8. Thermal and optical properties of electron beam irradiated cellulose triacetate

    Science.gov (United States)

    Nouh, S. A.; Mohamed, Amal; El Hussieny, H. M.

    2009-06-01

    Samples from Cellulose triacetate (CTA) sheets were irradiated with electron beam in the dose range 10-200 kGy. Non-isothermal studies were carried out using thermogravimetric analysis (TGA) to obtain the activation energy of thermal decomposition for CTA polymer. The CTA samples decompose in one main break down stage. The results indicate that the irradiation by electron beam in the dose range 80-200 kGy increases the thermal stability of the polymer samples. Also, the variation of melting temperatures with the electron dose has been determined using differential thermal analysis (DTA). The CTA polymer is characterized by the appearance of one endothermic peak due to melting. It is found that the irradiation in the dose range 10-80 kGy causes defects generation that splits the crystals depressing the melting temperature, while at higher doses (80-200 kGy), the thickness of crystalline structure (lamellae) is increased, thus the melting temperature increases. In addition, the transmission of these samples in the wavelength range 200-2500 nm, as well as any color changes, were studied. The color intensity Δ E* was greatly increased on increasing the electron beam dose, and accompanied by a significant increase in the blue color component.

  9. The electron beam cure of epoxy paste adhesives

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J.D. [Air Force Advanced Composites Program office, McClellan AFB, CA (United States); Janke, C.J. [Oak Ridge National Lab., TN (United States). Oak Ridge Centers for Manufacturing Technology; Lopata, V.J. [Atomic Energy of Canada Ltd., Pinawa, Manitoba (Canada). Whiteshell Labs.

    1998-07-01

    Recently developed epoxy paste adhesives were electron beam cured and experimentally explored to determine their suitability for use in an aerospace-quality aircraft component. There were two major goals for this program. The first was to determine whether the electron beam-curable past adhesives were capable of meeting the requirements of the US Air Force T-38 supersonic jet trainer composite windshield frame. The T-38 windshield frame`s arch is currently manufactured by bonding thin stainless steel plies using an aerospace-grade thermally-cured epoxy film adhesive. The second goal was to develop the lowest cost hand layup and debulk process that could be used to produce laminated steel plies with acceptable properties. The laminate properties examined to determine adhesive suitability include laminate mechanical and physical properties at room, adhesive tack, out-time capability, and the debulk requirements needed to achieve these properties. Eighteen past adhesives and four scrim cloths were experimentally examined using this criteria. One paste adhesive was found to have suitable characteristics in each of these categories and was later chosen for the manufacture of the T-38 windshield frame. This experimental study shows that by using low-cost debulk and layup processes, the electron beam-cured past adhesive mechanical and physical properties meet the specifications of the T-38 composite windshield frame.

  10. Fixation mechanisms of nanoparticles on substrates by electron beam irradiation.

    Science.gov (United States)

    Morioka, Daichi; Nose, Tomohiro; Chikuta, Taiki; Mitsuishi, Kazutaka; Shimojo, Masayuki

    2017-01-01

    For applications such as the fabrication of plasmonic waveguides we developed a patterning technique to fabricate an array of nanoparticles on a substrate using focused electron beams (Noriki, T.; Abe, S.;.Kajikawa, K.; Shimojo, M. Beilstein J. Nanotechnol.2015,6, 1010-1015). This technique consists of three steps: Firstly, nanoparticles are placed over the entire surface of a substrate. Secondly, the nanoparticles are fixed on the substrate by focused electron beam irradiation. The electron beam decomposes the organic molecules located around the particle into amorphous carbon. The amorphous carbon immobilizes the particle on the substrate. Finally, the unfixed nanoparticles are removed. However, in this original technique, the area in which the nanoparticles were fixed was wider than the electron-probe size of a few nanometers. To understand this widening mechanisms, the effects of accelerating voltage, particle size and substrate material are investigated by means of both experiments and simulation. It is demonstrated that the fixing area is greatly affected by the electrons back-scattered by the substrate. The back-scattering leads to an increase in line width and thus reduces the resolution of this patterning technique.

  11. Electrical Characterisation of electron beam exposure induced Defects in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Danga, Helga T., E-mail: helga.danga@up.ac.za; Auret, Francois D.; Coelho, Sergio M.M.; Diale, Mmantsae

    2016-01-01

    The defects introduced in epitaxially grown p-type silicon (Si) during electron beam exposure were electrically characterised using deep level transient spectroscopy (DLTS) and high resolution Laplace-DLTS. In this process, Si samples were first exposed to the conditions of electron beam deposition (EBD) without metal deposition. This is called electron beam exposure (EBE) herein. After 50 minutes of EBE, nickel (Ni) Schottky contacts were fabricated using the resistive deposition method. The defect level observed using the Ni contacts had an activation energy of H(0.55). This defect has an activation energy similar to that of the I-defect. The defect level is similar to that of the HB4, a boron related defect. DLTS depth profiling revealed that H(0.55) could be detected up to a depth of 0.8 μm below the junction. We found that exposing the samples to EBD conditions without metal deposition introduced a defect which was not introduced by the EBD method. We also observed that the damage caused by EBE extended deeper into the material compared to that caused by EBD.

  12. Superconducting properties of niobium after electron beam welding

    Directory of Open Access Journals (Sweden)

    Prakash N. Potukuchi

    2011-12-01

    Full Text Available One of the major criteria for designing superconducting niobium resonant cavities is to minimize the peak surface electric and magnetic fields to maximize the achievable accelerating electric gradient. Even after addressing the extrinsic effects adequately, a large number of cavities perform below the theoretical gradient limit. The peak magnetic field for the first flux-line penetration in the superconducting state of niobium, which either severely degrades the cavity quality factor or results in complete thermal breakdown, is an important limitation. The flux-line penetration is known to depend on the microstructural properties of niobium which may get altered in the process of cavity fabrication. The most common technique of fabricating niobium cavities is to form their components using standard sheet metal techniques and join them by electron beam welding in vacuum. We present results of a study on the superconducting response through magnetization measurements in the electron beam welded region of niobium to understand the limitations (if any posed by the welding in achieving the highest gradient. We also present and discuss results on the performance of niobium quarter wave resonators incorporating such electron beam welds in the high magnetic field region.

  13. High electron beam dosimetry using ZrO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Lueza M, F.; Rivera M, T. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, IPN, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Garcia H, M. [Instituto de Investigaciones en Materiales, UNAM, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2009-10-15

    This paper reports the experimental results of studying the thermoluminescent (Tl) properties of ZrO{sub 2} powder embedded in polytetrafluorethylene (PTFE) exposed to high energy electron beam from linear accelerators (Linac). Structural and morphological characteristics were also reported. Irradiations were conducted using high energy electrons beams in the range from 2 to 18 MeV. Pellets of ZrO{sub 2}+PTFE were produced using polycrystalline powder grown by the precipitation method. These pellets presented a Tl glow curve exhibiting an intense glow peak centered at around 235 C. Tl response as a function of high electron absorbed dose was linear in the range from 2 to 30 Gy. Repeatability determined by exposing a set of pellets repeatedly to the same electron absorbed dose was 0.5%. Fading along 30 days was about 50%. Then, results obtained in this study suggest than ZrO{sub 2}+PTFE pellets could be used for high energy electron beam dosimetry provided fading correction is accounted for. (Author)

  14. Spatial Control of Laser Wakefield Accelerated Electron Beams

    Science.gov (United States)

    Maksimchuk, A.; Behm, K.; Zhao, T.; Joglekar, A. S.; Hussein, A.; Nees, J.; Thomas, A. G. R.; Krushelnick, K.; Elle, J.; Lucero, A.; Samarin, G. M.; Sarry, G.; Warwick, J.

    2017-10-01

    The laser wakefield experiments to study and control spatial properties of electron beams were performed using HERCULES laser at the University of Michigan at power of 100 TW. In the first experiment multi-electron beam generation was demonstrated using co-propagating, parallel laser beams with a π-phase shift mirror and showing that interaction between the wakefields can cause injection to occur for plasma and laser parameters in which a single wakefield displays no significant injection. In the second experiment a magnetic triplet quadrupole system was used to refocus and stabilize electron beams at the distance of 60 cm from the interaction region. This produced a 10-fold increase in remote gamma-ray activation of 63Cu using a lead converter. In the third experiment measurements of un-trapped electrons with high transverse momentum produce a 500 mrad (FWHM) ring. This ring is formed by electrons that receive a forward momentum boost by traversing behind the bubble and its size is inversely proportional to the plasma density. The characterization of divergence and charge of this electron ring may reveal information about the wakefield structure and trapping potential. Supported by U.S. Department of Energy and the National Nuclear Security Administration and Air Force Office of Scientific Research.

  15. Injection of an overdense electron beam in space

    Science.gov (United States)

    Okuda, Hideo; Ashour-Abdalla, Maha

    1990-01-01

    A three-dimensional particle simulation model is used to study the injection and propagation of an overdense electron beam in the vicinity of a conductor in space. Beam electrons with a density of more than 100 times the ambient electron density are modeled using large-scale plasma simulations; in these simulations the surface area of the conductor is several thousands times that of the beam cross section at the injection point. The parameters of the simulations are chosen to allow the realistic simulation of active space experiments such as the Space Shuttle's Spacelab 2 electron beam mission. These simulations confirm space observations that an overdense electron beam can at least partially escape the near vicinity of the spacecraft, even in a fully ionized plasma. Once they have escaped from the vicinity of the spacecraft, these beam electrons should be able to propagate away freely until their energy is dissipated. It is suggested that such large-scale simulations could be useful in interpreting data from space experiments.

  16. Excitation of Plasma Waves in Aurora by Electron Beams

    Science.gov (United States)

    daSilva, C. E.; Vinas, A. F.; deAssis, A. S.; deAzevedo, C. A.

    1996-01-01

    In this paper, we study numerically the excitation of plasma waves by electron beams, in the auroral region above 2000 km of altitude. We have solved the fully kinetic dispersion relation, using numerical method and found the real frequency and the growth rate of the plasma wave modes. We have examined the instability properties of low-frequency waves such as the Electromagnetic Ion Cyclotron (EMIC) wave as well as Lower-Hybrid (LH) wave in the range of high-frequency. In all cases, the source of free energy are electron beams propagating parallel to the geomagnetic field. We present some features of the growth rate modes, when the cold plasma parameters are changed, such as background electrons and ions species (H(+) and O(+)) temperature, density or the electron beam density and/or drift velocity. These results can be used in a test-particle simulation code, to investigate the ion acceleration and their implication in the auroral acceleration processes, by wave-particle interaction.

  17. Electron beam detection of a Nanotube Scanning Force Microscope.

    Science.gov (United States)

    Siria, Alessandro; Niguès, Antoine

    2017-09-14

    Atomic Force Microscopy (AFM) allows to probe matter at atomic scale by measuring the perturbation of a nanomechanical oscillator induced by near-field interaction forces. The quest to improve sensitivity and resolution of AFM forced the introduction of a new class of resonators with dimensions at the nanometer scale. In this context, nanotubes are the ultimate mechanical oscillators because of their one dimensional nature, small mass and almost perfect crystallinity. Coupled to the possibility of functionalisation, these properties make them the perfect candidates as ultra sensitive, on-demand force sensors. However their dimensions make the measurement of the mechanical properties a challenging task in particular when working in cavity free geometry at ambient temperature. By using a focused electron beam, we show that the mechanical response of nanotubes can be quantitatively measured while approaching to a surface sample. By coupling electron beam detection of individual nanotubes with a custom AFM we image the surface topography of a sample by continuously measuring the mechanical properties of the nanoresonators. The combination of very small size and mass together with the high resolution of the electron beam detection method offers unprecedented opportunities for the development of a new class of nanotube-based scanning force microscopy.

  18. Electron beam energy QA - a note on measurement tolerances.

    Science.gov (United States)

    Meyer, Juergen; Nyflot, Matthew J; Smith, Wade P; Wottoon, Landon S; Young, Lori; Yang, Fei; Kim, Minsun; Hendrickson, Kristi R G; Ford, Eric; Kalet, Alan M; Cao, Ning; Dempsey, Claire; Sandison, George A

    2016-03-08

    Monthly QA is recommended to verify the constancy of high-energy electron beams generated for clinical use by linear accelerators. The tolerances are defined as 2%/2 mm in beam penetration according to AAPM task group report 142. The practical implementation is typically achieved by measuring the ratio of readings at two different depths, preferably near the depth of maximum dose and at the depth corresponding to half the dose maximum. Based on beam commissioning data, we show that the relationship between the ranges of energy ratios for different electron energies is highly nonlinear. We provide a formalism that translates measurement deviations in the reference ratios into change in beam penetration for electron energies for six Elekta (6-18 MeV) and eight Varian (6-22 MeV) electron beams. Experimental checks were conducted for each Elekta energy to compare calculated values with measurements, and it was shown that they are in agreement. For example, for a 6 MeV beam a deviation in the measured ionization ratio of ± 15% might still be acceptable (i.e., be within ± 2 mm), whereas for an 18 MeV beam the corresponding tolerance might be ± 6%. These values strongly depend on the initial ratio chosen. In summary, the relationship between differences of the ionization ratio and the corresponding beam energy are derived. The findings can be translated into acceptable tolerance values for monthly QA of electron beam energies.

  19. Electron Beam Charge Diagnostics for Laser Plasma Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Smith, Alan; Rodgers, David; Donahue, Rich; Byrne, Warren; Leemans, Wim

    2011-06-27

    A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/(ps mm{sup 2}), respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within {+-}8%, showing that they all can provide accurate charge measurements for LPAs.

  20. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    Science.gov (United States)

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV.

  1. Interaction of a Relativistic Electron Beam with Magnetized Plasma

    Science.gov (United States)

    Dorfman, Seth; Roytershteyn, Vadim; Cattell, Cynthia; van Compernolle, Bart; Delzanno, Gian Luca

    2017-10-01

    The interaction between relativistic electron beams and a magnetized plasma is a fundamental and practical problem that is relevant to many challenging issues in space physics and astrophysics. For example, it is well known that energetic particles in the Earth's radiation belts pose a danger to communication satellites. Compact electron beam sources may be used on future spacecraft to generate waves that would remove the energetic particles from the radiation belt region. A full understanding of the physics of these waves may also shed light on the mechanism for type II/III solar radio emissions. This talk will discuss experiments proposed to further advance understanding of the physical mechanisms governing beam-plasma interactions. The experiments and supporting simulations will investigate in detail the types of waves (whistler, Langmuir, etc.) produced by high-energy beams, beam stability, and feasibility for future space-based experiments. Experiments will be conducted on the Large Plasma Device (LAPD) at UCLA using a unique variable-energy electron beam recently developed at Los Alamos. We will discuss the proposed experimental setup as well as ongoing feasibility studies conducted using theoretical estimates and kinetic simulations. Supported by NSF.

  2. A study about the effects of gamma radiation and electron beam irradiation in the detection of genetically modified maize (Zea Mays); Estudos dos efeitos da radiacao gama e de aceleradores de eletrons na deteccao de graos de milho (Zea mays) geneticamente modificado

    Energy Technology Data Exchange (ETDEWEB)

    Crede, Ricardo Gandara

    2005-07-01

    of {sup 60}Co Irradiator Gamma Cell-220 and electron beam irradiation (Radiation Dynamics Inc. USA) were used (Atomic Energy of Canada, LTD), applying doses of 1, 25 and 50 kGy. After irradiating the samples, the detection results were compared with non-irradiated samples, showing that, when the PCR technique, was used, the irradiation does not affect the perception of the genetically modified maize. (author)

  3. Electron beam technology for multipollutant emissions control from heavy fuel oil-fired boiler.

    Science.gov (United States)

    Chmielewski, Andrzej G; Ostapczuk, Anna; Licki, Janusz

    2010-08-01

    The electron beam treatment technology for purification of exhaust gases from the burning of heavy fuel oil (HFO) mazout with sulfur content approximately 3 wt % was tested at the Institute of Nuclear Chemistry and Technology laboratory plant. The parametric study was conducted to determine the sulfur dioxide (SO2), oxides of nitrogen (NO(x)), and polycyclic aromatic hydrocarbon (PAH) removal efficiency as a function of temperature and humidity of irradiated gases, absorbed irradiation dose, and ammonia stoichiometry process parameters. In the test performed under optimal conditions with an irradiation dose of 12.4 kGy, simultaneous removal efficiencies of approximately 98% for SO2, and 80% for NO(x) were recorded. The simultaneous decrease of PAH and one-ringed aromatic hydrocarbon (benzene, toluene, and xylenes [BTX]) concentrations was observed in the irradiated flue gas. Overall removal efficiencies of approximately 42% for PAHs and 86% for BTXs were achieved with an irradiation dose 5.3 kGy. The decomposition ratio of these compounds increased with an increase of absorbed dose. The decrease of PAH and BTX concentrations was followed by the increase of oxygen-containing aromatic hydrocarbon concentrations. The PAH and BTX decomposition process was initialized through the reaction with hydroxyl radicals that formed in the electron beam irradiated flue gas. Their decomposition process is based on similar principles as the primary reaction concerning SO2 and NO(x) removal; that is, free radicals attack organic compound chains or rings, causing volatile organic compound decomposition. Thus, the electron beam flue gas treatment (EBFGT) technology ensures simultaneous removal of acid (SO2 and NO(x)) and organic (PAH and BTX) pollutants from flue gas emitted from burning of HFO. This technology is a multipollutant emission control technology that can be applied for treatment of flue gas emitted from coal-, lignite-, and HFO-fired boilers. Other thermal processes such

  4. Microstructure and deformation behavior of nickel based superalloy Inconel 740 prepared by electron beam smelting

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Yi, E-mail: tanyi@dlut.edu.cn; You, Xiaogang; You, Qifan; Li, Jiayan; Shi, Shuang; Li, Pengting

    2016-04-15

    Electron beam smelting (EBS) has been used to fabricate the Inconel 740 superalloy. Microstructures, hardness, and deformation characteristics of the alloy are studied. It is observed that carbides and fine secondary phase nuclei are distributed in the hot worked EBS 740 superalloy. The Ostwald ripening occurs during solution treatment and leads to aggregation of the γ′ precipitates, the size of γ′ precipitates varies from several nanometers to more than one hundred nanometers as a result. The average size of the secondary phase is < 30 nm after aging treatment and the average Vickers hardness is measured to be about 370. The critical shear stress is calculated to be 0.627 GPa with governing mechanism of shearing, causing a stronger strengthening effect than the traditionally prepared Inconel 740 superalloy. The compression behavior indicates that the EBS 740 superalloy shows higher flow stress than 740H at low Zener-Hollomon parameter, which may arise from the undissolved γ′ precipitates and higher activation energy Q. The tensile results show that the fracture surface exhibits a ductile fracture pattern, in contrast to no obvious plastic deformation on the macroscopic fracture. Crack propagation proceeds in a transgranular fracture mode with facets and voids presented on the fracture surface. - Graphical abstract: Electron beam smelting (EBS) has been used to fabricate the Inconel 740 superalloy. Microstructures, hardness, and deformation characteristics of the alloy are studied. The average size of the secondary phase is < 30 nm after aging treatment and the average Vickers hardness is measured to be about 370. The critical shear stress is calculated to be 0.627 GPa with governing mechanism of shearing, causing a stronger strengthening effect than the traditionally prepared Inconel 740 superalloy. The EBS 740 superalloy shows higher flow stress than 740H at low Zener-Hollomon parameter, which may arise from the undissolved γ′ precipitates and higher

  5. Role of total skin electron beam therapy for leukemia cutis in pediatric patients.

    Science.gov (United States)

    Pepek, Joseph M; Paulino, Arnold C; Briones, Michael A; Marcus, Robert B; Esiashvili, Natia

    2008-05-01

    The role of radiation therapy for those with leukemia cutis, particularly pediatric patients, remains unclear. This report describes the first two cases of disseminated leukemia cutis in adolescents treated with total skin electron beam therapy. Both patients had resolution of their skin disease and significant palliation of symptoms. Total skin electron irradiation is an option for adolescents suffering from significant extramedullary leukemia involving the skin. While it is uncertain if this treatment has any improvement in disease-free survival, the benefits of total skin electron therapy for symptom palliation should be considered. (c) 2008 Wiley-Liss, Inc.

  6. Clinical implementation of total skin electron beam (TSEB) therapy: a review of the relevant literature.

    Science.gov (United States)

    Diamantopoulos, S; Platoni, K; Dilvoi, M; Nazos, I; Geropantas, K; Maravelis, G; Tolia, M; Beli, I; Efstathopoulos, E; Pantelakos, P; Panayiotakis, G; Kouloulias, V

    2011-04-01

    Total skin electron beam therapy has been in medical service since the middle of the last century in order to confront rare skin malignancies. Since then various techniques have been developed, all aiming at better clinical results in conjunction with less post-irradiation complications. In this article every available technique is presented in addition to physical parameters of technique establishment and common dose fractionation. This study also revealed the preference of the majority of institutes the last 20 years in "six dual field technique" at a high dose rate, which is a safe and effective treatment. Copyright © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. High-cycle Fatigue Properties of Alloy718 Base Metal and Electron Beam Welded Joint

    Science.gov (United States)

    Ono, Yoshinori; Yuri, Tetsumi; Nagashima, Nobuo; Sumiyoshi, Hideshi; Ogata, Toshio; Nagao, Naoki

    High-cycle fatigue properties of Alloy 718 plate and its electron beam (EB) welded joint were investigated at 293 K and 77 K under uniaxial loading. At 293 K, the high-cycle fatigue strength of the EB welded joint with the post heat treatment exhibited somewhat lower values than that of the base metal. The fatigue strengths of both samples basically increased at 77 K. However, in longer life region, the EB welded joint fractured from a blow hole formed in the welded zone, resulting in almost the same fatigue strength at 107 cycles as that at 293 K.

  8. Enhancing effect by electron beam irradiation on immunomodulating and antitumor activity of b-glucan in mice

    Energy Technology Data Exchange (ETDEWEB)

    Yeo, A Reum; Lee, Jung Lim; Park, Seok Rae; Yoo, Yung Choon [Konyang Univ., Daejeon (Korea, Republic of); Kim, Jae Hoon; Lee, Ju Woon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-07-01

    In this study, in order to investigated the effect of electron beam irradiation to b-glucan on its biological activities, we compared anti-allergic and antitumor activity between non-irradiated and electron beam-irradiated b-glucan. EDB-glucan was irradiated by electron beam with 50 kGy. Treatment of EDB-glucan, but not NCI-glucan also significantly inhibited T cell proliferation and cytokine production in response to the same allergen Ova. However EDB-glucan did not affect the production of Ova-specific IgG, IgA and IgM. In experiments of antitumor activity, EDB-glucan treated with 50 kGy prior to tumor inoculation inhibited an experimental lung metastasis produced by B/E-B/L melanoma cells in mice. The same effect of EDB-glucan treated with 50 kGy induced a decrease of tumor growth in tumor-bearing mice. Collective, these results indicates that electron beam irradiation to b-glucan leads to inhibit allergic responses, and enhance antitumor activity.

  9. Improvement of optical properties of TiO2 thin film treated with electron beam.

    Science.gov (United States)

    Shin, Joong-Hyeok; Lee, Byung Cheol; Woo, Hee-Gweon; Hwang, Kwang Ha; Jun, Jin

    2013-03-01

    Nanocrystalline titanium dioxide (TiO2) thin films on silicon wafer substrates were prepared by sol-gel spin coating process. The prepared thin films were treated with electron beam (1.1 MeV, 300 kGy) at air atmosphere. The effects of electron-beam (EB) irradiation on the structural and optical properties of the TiO2 thin films were investigated. The structures of all the TiO2 thin films by XRD analysis showed an anatase phase, and the phase remained unchanged within the investigating range of EB treatment. The thickness of the titania thin film decreased slightly with EB treatment whereas the porosity increased. The EB treatment of TiO2 thin film can increase the proportion of Ti3+ in Ti2p at the thin film surface. The optical transmittance of the film in the wavelength ranges of above 380 nm increased after the EB treatment while its refractive index decreased with increasing EB dose. Therefore, improvement of the optical properties could be due to the change in both surface chemistry and morphology of the TiO2 thin films affected by EB irradiation.

  10. Experimental and statistical models of impact determination of the electron beam parameters on surface layers properties of optical elements in precision instruments building

    Directory of Open Access Journals (Sweden)

    I.V. Yatsenko

    2016-05-01

    Full Text Available Modern devices with optical elements for measurement and thermal control of different physical nature objects subjected to intense external thermal actions. To prevent destruction of optical elements the electron beam methods of work surfaces finishing at the stage of manufacture has practical significance. These methods can improve the properties of the element surface layers and thus make them more resistant to external thermal and mechanical action. Aim: The aim is to determine the optimal ranges of parameters of the electron beam and the development of experimental and statistical models that will automatically generate database with improved properties of the surface layers of optical elements in real time mode after previous electron beam treatment. Materials and Methods: To study the influence of parameters of the electron beam on the properties of the surface layers of the optical elements used plates of optical glass (K8, K108, etc. and ceramics (KO1, KO2, etc.. The strip electron beam has the following characteristics: density of heat flow Fn = 5∙10^6…9∙10^8 W/m2 and rate of displacement V = 0…0.1 m/s. Determination of the surface layers properties of the optical elements before and after electron beam treatment was carried out by known methods of physical and chemical analysis. Results: It was established that under the influence of the electron beam on the surface of the optical element there is visible clearing of various impurities take place, various micro-defects that remain on it after standard processing methods (mechanical, chemical, etc. remove and also its smoothness significantly increases, i.e. height of residual asperities on the surface is reduced. It was also found that the processing of optical glass elements by electron beam their surface layers change their structure, which is close to the quartz. It is shown that the surface of the preprocessed electron beam elements able to withstand the critical value of

  11. Multiple pulse electron beam converter design for high power radiography

    Science.gov (United States)

    Pincosy, P. A.; Back, N.; Bergstrom, P. M.; Chen, Yu-Jiuan; Poulsen, P.

    2001-06-01

    The typical response of the x-ray converter material to the passage of a high-powered relativistic electron beam is vaporization and rapid dispersal. The effect of this dispersal on subsequent pulses for multi-pulse radiography is the collective effects on the propagation of the electron beam through the expanding plasma and the reduced number of electron to photon interactions. Thus, for the dual-axis radiographic hydrodynamic test facility, the converter material must either be replaced or confined long enough to accommodate the entire pulse train. Typically the 1-mm-thick high Z and full density converter material is chosen to give peak dose and minimum radiographic spot. For repeated pulses we propose a modified converter, constructed of either low density, high Z material in the form of foam or of foils spaced over ten times the axial thickness of the standard 1 mm converter. The converter material is confined within a tube to impede outward motion in radius outside the beam interaction region. We report single-pulse experiments which measure the dose and spot size produced by the modified converter and compare them to similar measurements made by the standard converter. For multiple pulses over a microsecond time scale, we calculate the radial and axial hydrodynamic flow to study the material reflux into the converter volume and the resultant density decrease as the electron beam energy is deposited. Both the electron transport through the expanding low density plasma and beam in the higher density material are modeled. The x-ray source dose and spot size are calculated to evaluate the impact of the changing converter material density distribution on the radiographic spot size and dose. The results indicate that a multiple-pulse converter design for three or four high-power beam pulses is feasible.

  12. Model of convection mass transfer in titanium alloy at low energy high current electron beam action

    Science.gov (United States)

    Sarychev, V. D.; Granovskii, A. Yu; Nevskii, S. A.; Konovalov, S. V.; Gromov, V. E.

    2017-01-01

    The convection mixing model is proposed for low-energy high-current electron beam treatment of titanium alloys, pre-processed by heterogeneous plasma flows generated via explosion of carbon tape and powder TiB2. The model is based on the assumption vortices in the molten layer are formed due to the treatment by concentrated energy flows. These vortices evolve as the result of thermocapillary convection, arising because of the temperature gradient. The calculation of temperature gradient and penetration depth required solution of the heat problem with taking into account the surface evaporation. However, instead of the direct heat source the boundary conditions in phase transitions were changed in the thermal conductivity equation, assuming the evaporated material takes part in the heat exchange. The data on the penetration depth and temperature distribution are used for the thermocapillary model. The thermocapillary model embraces Navier-Stocks and convection heat transfer equations, as well as the boundary conditions with the outflow of evaporated material included. The solution of these equations by finite elements methods pointed at formation of a multi-vortices structure when electron-beam treatment and its expansion over new zones of material. As the result, strengthening particles are found at the depth exceeding manifold their penetration depth in terms of the diffusion mechanism.

  13. Use of electron beam for the production of hydrogel dressings

    Energy Technology Data Exchange (ETDEWEB)

    Ajji, Z. [Polymer Technology Division, Department of Radiation Technology, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)], E-mail: zajji@aec.org.sy; Mirjalili, G. [Yazd Radiation Processing Center, P.O. Box 89175-389, Yazd (Iran, Islamic Republic of); Alkhatab, A.; Dada, H. [Polymer Technology Division, Department of Radiation Technology, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)

    2008-02-15

    The electron beam irradiation technique has been utilized to prepare hydrogel wound dressings. The composition of the dressings is based on polyvinylpyrrolidone (PVP), poly(ethylene glycol) (PEG), and agar. Increasing the irradiation dose leads to an increase in the gel fraction; this increase is due to increased crosslink density. The gel fraction% decreases as the PEG concentration increases. The maximum swelling% decreases with increasing the irradiation dose, but increases with increasing the PEG concentration. This relationship can be utilized to modify the gel properties as gel fraction% and maximum swelling of the hydrogel. The prepared dressings could be considered as a good barrier against microbes.

  14. Electromagnetic interactions between a fast electron beam and metamaterial cloaks

    Science.gov (United States)

    Xu, Jinying; Dong, Yunxia; Zhang, Xiangdong

    2008-10-01

    Relativistic energy loss and photon emission in the interaction of ideal and nonideal metamaterial cloaks with an external electron beam are studied based on the classical electrodynamics. The effects of various imperfect parameters on the efficiency of the cloak are emphasized. The energy-loss spectra and the photon emission for such structures with the different combinations of electron velocity and impact parameter are calculated. It is shown that the efficiency of nonideal electromagnetic cloaks and the effect of various nonideal parameters on the cloak invisibility can be exhibited in the electron energy loss spectroscopy. This means that the properties of cloak can be explored by scanning transmission electron microscopy.

  15. Crosslinked blends and coextruded films by electron beam

    Science.gov (United States)

    Vallat, M. F.; Marouani, S.; Perraud, S.; Mendoza Patlan, N.

    2005-07-01

    Morphology, thermal and mechanical properties of polymer blends and coextruded films of hydrogenated copolymer of butadiene and acrylonitrile (HNBR) and polyethylene-co-octene (PE-co-O) are considered before and after electron beam crosslinking. It is known that the properties are depending not only on the crosslinks in the bulk of the polymers but also on that created in the interfacial domain. It is however very difficult to have direct evidence of the interfacial crosslinks. Moreover the two polymers are not compatible and the addition of an ethylene vinyl acetate copolymer as a potential polymer compatibiliser is considered.

  16. Remote use of an Electron Beam Tester (EBT)

    Science.gov (United States)

    Baille, G.; Conquet, F.; Devautour, B.; Gouyon, T.

    1988-10-01

    The first remote use of the TIM3 experimental electron beam tester is described. Thanks to modern lines, it is possible to manage the TESSIE exerciser from any remote terminal. The test pattern memory can be loaded, dumped or modified. The output pattern memory (analysis) can be loaded with circuit truth tables or with the answers given by a golden chip, dumped in a file for future use. Other remote management possibilities are described. Future developments such as transmission of images, simulation and test tool techniques are outlined.

  17. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k...

  18. Microbial Safety Improvement of Sea Buckthorn by Electron Beam Irradiation

    Science.gov (United States)

    Nemţanu, Monica R.; Minea, R.; Mazilu, Elena; Rǎdulescu, Nora

    2007-04-01

    The commercialization of medicinal plants and/or their products is highly increased in Romania lately. One of the most used herbs is sea buckthorn being well known for its quality with a large potential for curing some diseases. Sea buckthorn can be contaminated with undesirable microorganisms which may affect negatively its quality. The paper presents the results regarding the action of a non-conventional technology meaning electron beam technique on sea buckthorn in order to improve its microbiological quality. Our study revealed that the sea buckthorn microbial load has been improved after 3 kGy irradiation keeping its active principles.

  19. Electron Beam Møller Polarimeter at Jlab Hall a

    CERN Document Server

    Glamazdin, A V; Levchuk, L G; Pomatsalyuk, R I; Rubashkin, A L; Sorokin, P V; Dale, D S; Doyle, B; Gorringe, T P; Korsch, W; Zeps, V; Chen, J P; Chudakov, E A; Nanda, S; Saha, A; Gasparian, A

    1999-01-01

    As part of the spin physics program at Jefferson Laboratory (JLab), a Mø ller polarimeter was developed to measure the polarization of electron beam of energies 0.8 to 5.0 GeV. A unique signature for Mø ller scattering is obtained using a series of three quadrupole magnets which provide an angular selection, and a dipole magnet for energy analysis. The design, commissioning, and the first results of the polarization measurements of this polarimeter will be presented as well as future plans to use its small scattering angle capabilities to investigate physics in the very low $Q^2$ regime.

  20. Numerical simulation of electron beam welding and instrumental technique

    Energy Technology Data Exchange (ETDEWEB)

    Carin, M.; Rogeon, P.; Carron, D.; Le Masson, P.; Couedel, D. [Universite de Bretagne Sud, Centre de Recherche, Lab. d' Etudes Thermiques Energetique et Environnement, 56 - Lorient (France)

    2004-07-01

    In the present work, thermal cycles measured with thermocouples embedded in specimens are employed to validate a numerical thermo-metallurgical model of an Electron Beam welding process. The implemented instrumentation techniques aim at reducing the perturbations induced by the sensors in place. The numerical model is based on the definition of a heat source term linked to the keyhole geometry predicted by a model of pressure balance using the FEMLAB code. The heat source term is used by the thermo-metallurgical simulation carried out with the finite element code SYSWELD. Kinetics parameters are extracted from dilatometric experiments achieved in welding austenitization conditions at constant cooling rates. (authors)

  1. PtRu/C electrocatalysts prepared using electron beam irradiation

    Directory of Open Access Journals (Sweden)

    Dionísio Furtunato da Silva

    2007-12-01

    Full Text Available PtRu/C electrocatalysts (carbon-supported PtRu nanoparticles were prepared submitting water/ethylene glycol mixtures containing Pt(IV and Ru(III ions and the carbon support to electron beam irradiation. The electrocatalysts were characterized by energy dispersive X ray analysis (EDX, X ray diffraction (XRD and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained PtRu/C electrocatalysts showed superior performance for methanol electro-oxidation at room temperature compared to commercial PtRu/C electrocatalyst.

  2. Artificial auroras in the upper atmosphere. I - Electron beam injections

    Science.gov (United States)

    Burch, J. L.; Mende, S. B.; Kawashima, N.; Roberts, W. T.; Taylor, W. W. L.; Neubert, T.; Gibson, W. C.; Marshall, J. A.; Swenson, G. R.

    1993-03-01

    The Atlas-1 Spacelab payload's Space Experiments with Particle Accelerators generated artificial electron beams for the stimulation of auroral emissions at southern auroral latitudes. Optical measurements were made by the Shuttle Orbiter's onboard TV cameras, as well as by the Atmospheric Emissions Photometric Imager (in both white light and the 427.8 nm N2(+) emission line). Shuttle-based auroral imaging furnished a novel perspective on the artificial auroras; the emissions were traced from 295 km to the 110 km level along the curved magnetic-field lines.

  3. Upgrade of laser and electron beam welding database

    CERN Document Server

    Furman, Magdalena

    2014-01-01

    The main purpose of this project was to fix existing issues and update the existing database holding parameters of laser-beam and electron-beam welding machines. Moreover, the database had to be extended to hold the data for the new machines that arrived recently at the workshop. As a solution - the database had to be migrated to Oracle framework, the new user interface (using APEX) had to be designed and implemented with the integration with the CERN web services (EDMS, Phonebook, JMT, CDD and EDH).

  4. Emission of an intense electron beam from a ceramic honeycomb

    Science.gov (United States)

    Friedman, M.; Myers, M.; Hegeler, F.; Swanekamp, S. B.; Sethian, J. D.; Ludeking, L.

    2003-01-01

    Inserting a slab of honeycomb ceramic in front of the emitting surface of a large-area cathode improves the electron beam emission uniformity, decreases the beam current rise and fall times, and maintains a more constant diode impedance. Moreover, changing the cathode material from velvet to carbon fiber achieved a more robust cathode that starts to emit at a higher electric field without a degradation in beam uniformity. In addition, an 80% reduction in the postshot diode pressure was also observed when gamma alumina was deposited on the ceramic. A possible explanation is that reabsorption and recycling of adsorbed gases takes place.

  5. Artificial auroras in the upper atmosphere. I - Electron beam injections

    Science.gov (United States)

    Burch, J. L.; Mende, S. B.; Kawashima, N.; Roberts, W. T.; Taylor, W. W. L.; Neubert, T.; Gibson, W. C.; Marshall, J. A.; Swenson, G. R.

    1993-01-01

    The Atlas-1 Spacelab payload's Space Experiments with Particle Accelerators generated artificial electron beams for the stimulation of auroral emissions at southern auroral latitudes. Optical measurements were made by the Shuttle Orbiter's onboard TV cameras, as well as by the Atmospheric Emissions Photometric Imager (in both white light and the 427.8 nm N2(+) emission line). Shuttle-based auroral imaging furnished a novel perspective on the artificial auroras; the emissions were traced from 295 km to the 110 km level along the curved magnetic-field lines.

  6. Electron beam irradiation for biological decontamination of Spirulina platensis

    Energy Technology Data Exchange (ETDEWEB)

    Brasoveanu, Mirela [National Institute for Lasers, Plasma and Radiation Physics, Department of Electron Accelerators, 409 Atomistilor Street, P.O. Box MG-36, RO 76 900 Bucharest-Magurele (Romania)]. E-mail: mirela@infim.ro; Nemtanu, Monica [National Institute for Lasers, Plasma and Radiation Physics, Department of Electron Accelerators, 409 Atomistilor Street, P.O. Box MG-36, RO 76 900 Bucharest-Magurele (Romania); Minea, R. [National Institute for Lasers, Plasma and Radiation Physics, Department of Electron Accelerators, 409 Atomistilor Street, P.O. Box MG-36, RO 76 900 Bucharest-Magurele (Romania); Grecu, Maria Nicoleta [National Institute for Materials Physics, Bucharest-Magurele (Romania); Mazilu, Elena [Hofigal SA (Romania); Radulescu, Nora [Hofigal SA (Romania)

    2005-10-15

    The Cyanobacterium Spirulina is commercialized for its use in health foods and for therapeutic purposes due to its valuable constituents particularly proteins and vitamins. The aim of the paper is to study the Spirulina platensis behaviour when it is electron beam irradiated for biological decontamination. Microbial load, antioxidant activity, enzymatic inhibition, electron spin resonance (ESR) and UV-Vis spectra were measured for doses up to 80 kGy. The results were correlated with doses in order to find where decontamination is efficient, keeping the Spirulina qualities.

  7. Electron beam irradiation for biological decontamination of Spirulina platensis

    Science.gov (United States)

    Brasoveanu, Mirela; Nemtanu, Monica; Minea, R.; Grecu, Maria Nicoleta; Mazilu, Elena; Radulescu, Nora

    2005-10-01

    The Cyanobacterium Spirulina is commercialized for its use in health foods and for therapeutic purposes due to its valuable constituents particularly proteins and vitamins. The aim of the paper is to study the Spirulina platensis behaviour when it is electron beam irradiated for biological decontamination. Microbial load, antioxidant activity, enzymatic inhibition, electron spin resonance (ESR) and UV-Vis spectra were measured for doses up to 80 kGy. The results were correlated with doses in order to find where decontamination is efficient, keeping the Spirulina qualities.

  8. Combined electron beam and UV lithography in SU-8

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Morten; Thamdrup, Lasse Højlund; Mironov, Andrej

    2007-01-01

    We present combined electron beam and UV lithography (CEUL) in SU-8 as a fast and flexible lithographic technique for prototyping of functional polymer devices and pattern transfer applications. CEUL is a lithographic technique suitable for defining both micrometer and nanometer scale features...... in a single polymer film on the wafer scale. The height of the micrometer and nanometer scale features is matched within 30 nm. As a pattern transfer application, we demonstrate stamp fabrication and thermal nanoimprint of a 2-dimensional array of 100 nm wide lines with a pitch of 380 nm in connection...

  9. Daily check of the electron beams with a diode system

    Energy Technology Data Exchange (ETDEWEB)

    Pilette, P. [Hospital Civil de Charleroi (Belgium). Centre for Radiotherapy

    1995-12-01

    A fast systems to check all the accelerator beams on a daily basis has been developed. A cheap home-made detector, based on non-medical diodes (type 1N5408), has been used since July 1992 to verify all the electron beams every day. The relative energy and Top-cGy correspondence is verified with one single irradiation of less than 1 minute by 6 diodes fixed in a polystyrene phantom. The principle of construction, software implementation and results are presented.

  10. A comparative study on the effects of electron beam irradiation on imidacloprid-resistant and -susceptible Aphis gossypii (Hemiptera: Aphididae)

    Science.gov (United States)

    Yun, Seung-Hwan; Koo, Hyun-Na; Lee, Seon-Woo; Kim, Hyun Kyung; Kim, Yuri; Han, Bumsoo; Kim, Gil-Hah

    2015-07-01

    The melon and cotton aphid, Aphis gossypii, is a polyphagous insect pest. This study compared the development, reproduction, DNA damage, recovery, and gene expression in imidacloprid-resistant (IMI-R) and -susceptible (S) strains of A. gossypii by electron beam irradiation. When 1st instar nymphs were irradiated with 100 Gy, the fecundity (nymphs of F1 generation) of the resultant adults were completely inhibited. When adults were irradiated with 200 Gy, the number of total 1st instar nymphs produced per adult was 3.0±1.7 and 1.9±1.4 in the S and IMI-R strains, respectively, but adult development was completely suppressed. However, electron beam irradiation did not affect adult longevity in either the S or IMI-R strain. There was no statistically significant difference between the effect of irradiation on the S and IMI-R strains. Therefore, electron beam irradiation at 200 Gy could be used as a phytosanitary irradiation treatment for both S and IMI-R strains of A. gossypii. The DNA damage caused by electron beam irradiation was evaluated by an alkaline comet assay. Exposure to an electron beam (50 Gy) induced DNA damage that was repaired to a similar level as the untreated control group (0 Gy) over time. However, at more than 100 Gy, the DNA damage was not completely repaired. The expression of P450, HSP70, cuticle protein, and elongation factor genes were higher in the IMI-R strain than in the S strain.

  11. ESR dosimeter material properties of phenols compound exposed to radiotherapeutic electron beams

    Science.gov (United States)

    Gallo, Salvatore; Iacoviello, Giuseppina; Bartolotta, Antonio; Dondi, Daniele; Panzeca, Salvatore; Marrale, Maurizio

    2017-09-01

    There is a need for a sensitive dosimeter using Electron Spin Resonance spectroscopy for use in medical applications, since non-destructive read-out and dose archival could be achieved with this method. This work reports a systematic ESR investigation of IRGANOX ® 1076 exposed to clinical electron beams produced by a LINAC used for radiation therapy treatments. Recently, dosimetric features of this material were investigated for irradiation with 60Co γ -photons and neutrons in both pellet and film shape and have been found promising thanks to their high efficiency of radiation-matter energy transfer and radical stability at room temperature. Here the analysis of the dosimetric features of these ESR dosimeters exposed to clinical electron beams at energies of 7, 10 and 14 MeV, is described in terms of dependence on microwave power and modulation amplitude, response on dose, dependence on beam type, detection limits, and signal stability after irradiation. The analysis of the ESR signal as function of absorbed dose highlights that the response of this material is linear in the dose range investigated (1-13 Gy) and is independent of the beam energy. The minimum detectable dose is found to be smaller than 1 Gy. Comparison of electron stopping power values of these dosimeters with those of water and soft tissue highlights equivalence of the response to electron beams in the energy range considered. The signal intensity was monitored for 40 days after irradiation and for all energies considered and it shows negligible variations in the first 500 h after irradiation whereas after 1100 h the signal decay is only of about 4%. In conclusion, it is found that phenolic compounds possess good dosimetric features which make it useful as a sensitive dosimeter for medical applications.

  12. A kinetic sensitivity analysis for the SO2 and NOx removal using the electron beam technology

    Science.gov (United States)

    Zwolińska, Ewa; Gogulancea, Valentina; Sun, Yongxia; Lavric, Vasile; Chmielewski, Andrzej

    2017-09-01

    The mathematical modeling of the phenomena taking place during the electron beam flue gas treatment is a complex endeavor due to the different time scales of the processes occurring as accelerated electrons are bombarding the flue gas. The paper presents a complex kinetic model for these gas phase interactions, consisting of 1034 chemical reactions with the participation of 115 reactive species. The mathematical model couples the complex gas phase kinetics with a liquid phase kinetic model, taking into account the nucleation and condensation phenomena occurring due to the presence of sulfuric acid. The modeling results for both coupled and uncoupled gas phase kinetics are validated against a set of literature experimental data with satisfactory outcome. The work aims to identify the most important chemical reactions influencing the pollutants removal, proposing a sensitivity analysis using the concept of generated entropy. To the best of the authors' knowledge a sensitivity analysis of this extent has not been performed for the electron beam flue gas treatment. The results of this analysis emphasize the link between the removal efficiencies of NOx and SO2, the importance of hydroxyl radicals and can aid in future model reduction efforts.

  13. Modeling the influence of electron beam irradiation on the heat resistance of Bacillus cereus spores.

    Science.gov (United States)

    Valero, M; Sarrías, J A; Alvarez, D; Salmerón, M C

    2006-06-01

    The effect of electron beam irradiation (EBI) on Bacillus cereus spore heat resistance was investigated. Irradiation with accelerated electrons had an important heat-sensitizing effect on distilled-water spore suspensions. After irradiation doses of 1.3, 3.1, or 5.7 kGy followed by heating at 90 degrees C, calculated D(90)-values for strains Escuela Politécnica Superior de Orihuela (EPSO)-41WR and EPSO-50UR were reduced more than 1.3, 2.4, and 4.6 times, respectively. Plots of calculated log D(T)-values versus irradiation doses (1.3, 3.1, and 5.7 kGy) yielded straight parallel lines for the 85-100 degrees C heating temperature range, which made it possible to develop an equation to predict the changes in heat sensitivity of B. cereus spores that occurred with changing irradiation dose. Radiation-induced heat-sensitivity was characterized by a z(EBI)-value which was determined as the irradiation dose that should be required to reduce the decimal reduction time (D(T)) by one log(10) cycle when log(10)D(T) was plotted against irradiation treatment. A model is proposed to describe the influence of a pre-irradiation treatment with electron beams followed by heating on the heat resistance of B. cereus spores. This study also suggests the potential use of EBI followed by heating for food preservation.

  14. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  15. Quantitative Analysis of Electron Beam Damage in Organic Thin Films.

    Science.gov (United States)

    Leijten, Zino J W A; Keizer, Arthur D A; de With, Gijsbertus; Friedrich, Heiner

    2017-05-18

    In transmission electron microscopy (TEM) the interaction of an electron beam with polymers such as P3HT:PCBM photovoltaic nanocomposites results in electron beam damage, which is the most important factor limiting acquisition of structural or chemical data at high spatial resolution. Beam effects can vary depending on parameters such as electron dose rate, temperature during imaging, and the presence of water and oxygen in the sample. Furthermore, beam damage will occur at different length scales. To assess beam damage at the angstrom scale, we followed the intensity of P3HT and PCBM diffraction rings as a function of accumulated electron dose by acquiring dose series and varying the electron dose rate, sample preparation, and the temperature during acquisition. From this, we calculated a critical dose for diffraction experiments. In imaging mode, thin film deformation was assessed using the normalized cross-correlation coefficient, while mass loss was determined via changes in average intensity and standard deviation, also varying electron dose rate, sample preparation, and temperature during acquisition. The understanding of beam damage and the determination of critical electron doses provides a framework for future experiments to maximize the information content during the acquisition of images and diffraction patterns with (cryogenic) transmission electron microscopy.

  16. Excimer Emission using 20keV Electron Beam Excitation

    Science.gov (United States)

    Wieser, J.; Ulrich, A.; Murnick, D. E.

    1996-10-01

    A small, continuously emitting rare gas excimer light source has been developed. The gas is excited by a 20keV dc-electron beam. A 300nm thick, 1×1mm^2 SiNx foil sustaining a pressure difference up to 2bar, separates the target volume from the high vacuum part of the electron gun. Spectra of the rare gases Ar, Kr, and Xe have been studied. The monochromator detector system was intensity calibrated in the wavelength range from 115nm to 320nm. Electron beam currents of typically 1μA were used for excitation. When used as a VUV lamp on the second excimer continua, energy conversion efficiencies of 30% were obtained. Emissions originating from the so called left turning points have been clearly observed at 155, 173, and 222nm in Ar_2^*, Kr_2^*, and Xe_2^*, respectively. The so called third continua between 185nm and 240nm (Ar), 220nm and 250nm (Kr), and at 270nm (Xe) have been studied. A new continuum in Xe at 280nm was found. (Funded by the A.v.Humboldt Foundation and NSF (CTS 94-19440). The authors acknowledge support by H. Huggins, A. Liddle and W.L. Brown (Bell Laboratories, Lucent Technologies))

  17. Plasma sources for high-current electron beam generation

    Science.gov (United States)

    Krasik, Ya. E.; Dunaevsky, A.; Felsteiner, J.

    2001-05-01

    A review of experimental studies of the operation of cathodes made of metal-ceramic, velvet, corduroy, carbon fibers, carbon fabric, and different types of ferroelectrics is presented. These cathodes operated at electric fields in the range of 5-60 kV/cm that allowed the generation of electron beams with duration of several hundreds of nanoseconds while keeping a quasi-constant diode impedance. All cathodes had the same diameter and were tested in a diode powered by a high-voltage generator (300 kV, 85 Ω, 250 ns, ⩽5 Hz). It was shown that the source of electrons for all the studied cathodes is a plasma which is formed as a result of surface discharges. Different types of electrical and optical diagnostics were used to study the formation and parameters of the plasma, the potential distribution inside the anode-cathode gap, and the uniformity and divergence of the extracted electron beam as a function of the amplitude and rise time of the accelerating pulse. Results of the lifetime of the tested cathodes and their compatibility with vacuum requirements are presented as well.

  18. Electron Beam Diagnostics Of The JLAB UV FEL

    Energy Technology Data Exchange (ETDEWEB)

    Evtushenko, Pavel; Benson, Stephen; Biallas, George; Coleman, James; Dickover, Cody; Douglas, David; Marchlik, Matthew; Sexton, Daniel; Tennant, Christopher

    2011-03-01

    In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

  19. Electron beam final focus system for Thomson scattering at ELBE

    Energy Technology Data Exchange (ETDEWEB)

    Krämer, J.M., E-mail: jmkr@danfysik.dk [Danfysik A/S, Gregersensvej 8, 2630 Taastrup (Denmark); Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Technische Universität Dresden, 01069 Dresden (Germany); Budde, M.; Bødker, F. [Danfysik A/S, Gregersensvej 8, 2630 Taastrup (Denmark); Irman, A.; Jochmann, A. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Kristensen, J.P. [Danfysik A/S, Gregersensvej 8, 2630 Taastrup (Denmark); Lehnert, U.; Michel, P. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Schramm, U. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstrasse 400, 01328 Dresden (Germany); Technische Universität Dresden, 01069 Dresden (Germany)

    2016-09-11

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and divergences of about 10 mrad using the FFS.

  20. Effects of electron beam irradiation on bovine pericardium tissue

    Energy Technology Data Exchange (ETDEWEB)

    Polak, Roberta; Pitombo, Ronaldo N.M. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Ciencias Farmaceuticas. Dept. de Tecnologia Bioquimico-Farmaceutica], e-mail: robertaplk@gmail.com, e-mail: pitombo@usp.br; Rodas, Andrea C.D.; Higa, Olga Z. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia], e-mail: andrea.ipen@gmail.com, e-mail: ozhiga@ipen.br; Kodama, Yasko; Machado, Luci D.B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: ykodama@ipen.br

    2009-07-01

    In this work, electron beam irradiation was studied as a way for bovine pericardium (BP) tissue crosslinking. BP samples were irradiated in an electron beam accelerator at different doses (12.5 and 25 kGy), at three different dose ratios (4.67, 9.34 kGy/s), in the presence and absence of oxygen. Irradiated samples were analyzed by Differential Scanning Calorimetry (DSC), Thermogravimetry (TGA), Scanning Electron Microscopy (SEM) and swelling degree. DSC analysis showed a decrease in shrinkage temperature. However, for all irradiated samples, the energy required in the process was higher than the non irradiated BP. The TGA analysis showed that the thermal behavior, both the control and the irradiated samples, was characterized by three stages concerned in the loss of mass. The BP structure was characterized by swelling degree and SEM. The structure of the BP tissue suffered alteration, becoming looser, or more compact. By swelling degree, when the BP was irradiated in the presence of oxygen, the swelling degree value was higher than non irradiated BP, in the other hand the swelling degree value of BP irradiated in oxygen absence were lower than the non irradiated BP. Those results indicate that the BP irradiated in absence of oxygen could predominantly crosslinks. The BP degradation when it was irradiated in presence of oxygen was confirmed by SEM. (author)

  1. Particulate electron beam weld emission hazards in space

    Science.gov (United States)

    Bunton, Patrick H.

    1996-01-01

    The electron-beam welding process is well adapted to function in the environment of space. The Soviets were the first to demonstrate welding in space in the mid-1980's. Under the auspices of the International Space Welding Experiment (ISWE), an on-orbit test of a Ukrainian designed electron-beam welder (the Universal Hand Tool or 'UHT') is scheduled for October of 1997. The potential for sustained presence in space with the development of the international space station raises the possibility of the need for construction and repair in space. While welding is not scheduled to be used in the assembly of the space station, repair of damage from orbiting debris or meteorites is a potential need. Furthermore, safe and successful welding in the space environment may open new avenues for design and construction. The safety issue has been raised with regard to hot particle emissions (spatter) sometimes observed from the weld during operations. On earth the hot particles pose no particular hazard, but in space there exists the possibility for burn-through of the space suit which could be potentially lethal. Contamination of the payload bay by emitted particles could also be a problem.

  2. Electron beam final focus system for Thomson scattering at ELBE

    Science.gov (United States)

    Krämer, J. M.; Budde, M.; Bødker, F.; Irman, A.; Jochmann, A.; Kristensen, J. P.; Lehnert, U.; Michel, P.; Schramm, U.

    2016-09-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and divergences of about 10 mrad using the FFS.

  3. Medium and high energy electron beam processing system

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, Masayuki [Nissin-High Voltage Co., Ltd., Kyoto (Japan)

    2003-02-01

    Electron Beam Processing System (EPS) is a useful and powerful tool for industrial irradiation process. The specification of EPS is decided by consideration to irradiate what material with how thick and wide, how much dose, how to handle, in what atmosphere. In designing an EPS, it is necessary to consider safety measure such as x-ray shielding, ozone control and interlock system. The initial costs to install typical EPS are estimated for acceleration voltages from 500 kV to 5 MV, including following items; those are electron beam machine, x-ray shielding, auxiliary equipment, material handling, survey for installation, ozone exhaust duct, cooling water system, wiring and piping. These prices are reference only because the price should be changed for each case. The price of x-ray shielding should be changed by construction cost. Auxiliary equipment includes window, cooling blower, ozone exhaust blower and SF6 gas handling equipment. In installation work at site, actual workers of 3 - 4 persons for 2 months are necessary. Material handling system is considered only rolls provided in the shielding room as reference. In addition to the initial installation, operators and workers may be required to wear a personal radiation monitor. An x-ray monitor of suitable design should be installed outside the shield room to monitor x-ray level in the working area. (Y. Tanaka)

  4. Electron Beam Irradiated Intercalated CNT Yarns For Aerospace Applications

    Science.gov (United States)

    Waters, Deborah L.; Gaier, James R.; Williams, Tiffany S.; Lopez Calero, Johnny E.; Ramirez, Christopher; Meador, Michael A.

    2015-01-01

    Multi-walled CNT yarns have been experimentally and commercially created to yield lightweight, high conductivity fibers with good tensile properties for application as electrical wiring and multifunctional tendons. Multifunctional tendons are needed as the cable structures in tensegrity robots for use in planetary exploration. These lightweight robust tendons can provide mechanical strength for movement of the robot in addition to power distribution and data transmission. In aerospace vehicles, such as Orion, electrical wiring and harnessing mass can approach half of the avionics mass. Use of CNT yarns as electrical power and data cables could reduce mass of the wiring by thirty to seventy percent. These fibers have been intercalated with mixed halogens to increase their specific electrical conductivity to that near copper. This conductivity, combined with the superior strength and fatigue resistance makes it an attractive alternative to copper for wiring and multifunctional tendon applications. Electron beam irradiation has been shown to increase mechanical strength in pristine CNT fibers through increased cross-linking. Both pristine and intercalated CNT yarns have been irradiated using a 5-megavolt electron beam for various durations and the conductivities and tensile properties will be discussed. Structural information obtained using a field emission scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), and Raman spectroscopy will correlate microstructural details with bulk properties.

  5. Electron Beam Final Focus System For Thomson Scattering At Elbe

    CERN Document Server

    Krämer, J.M.; Bødkera, F.; Irman, A.; Jochmann, A.; Kristensena, J.P.; Lehnert, U.; Michel, P.; Schramm, U.; 10.1016/j.nima.2015.10.067

    2016-01-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and diverg...

  6. Electron beam final focus system for Thomson scattering at ELBE

    CERN Document Server

    Krämer, J.M.; Bødker, F.; Irman, A.; .Jochmann A.; Kristensen, J.P.; Lehnert U., HZDR; Michel, P.; Schrammb, U.; 10.1016/j.nima.2015.10.067

    2016-01-01

    The design of an electron beam final focus system (FFS) aiming for high-flux laser-Thomson backscattering X-ray sources at ELBE is presented. A telescope system consisting of four permanent magnet based quadrupoles was found to have significantly less chromatic aberrations than a quadrupole doublet or triplet as commonly used. Focusing properties like the position of the focal plane and the spot size are retained for electron beam energies between 20 and 30 MeV by adjusting the position of the quadrupoles individually on a motorized stage. The desired ultra-short electron bunches require an increased relative energy spread up to a few percent and, thus, second order chromatic effects must be taken into account. We also present the design and test results of the permanent magnet quadrupoles. Adjustable shunts allow for correction of the field strength and compensation of deviations in the permanent magnet material. For a beam emittance of 13 mm mrad, we predict focal spot sizes of about 40 μm (rms) and diverg...

  7. Optimization of Compton Source Performance through Electron Beam Shaping

    Energy Technology Data Exchange (ETDEWEB)

    Malyzhenkov, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Yampolsky, Nikolai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-26

    We investigate a novel scheme for significantly increasing the brightness of x-ray light sources based on inverse Compton scattering (ICS) - scattering laser pulses off relativistic electron beams. The brightness of ICS sources is limited by the electron beam quality since electrons traveling at different angles, and/or having different energies, produce photons with different energies. Therefore, the spectral brightness of the source is defined by the 6d electron phase space shape and size, as well as laser beam parameters. The peak brightness of the ICS source can be maximized then if the electron phase space is transformed in a way so that all electrons scatter off the x-ray photons of same frequency in the same direction, arriving to the observer at the same time. We describe the x-ray photon beam quality through the Wigner function (6d photon phase space distribution) and derive it for the ICS source when the electron and laser rms matrices are arbitrary.

  8. Total skin electron beam (TSEB) therapy in pediatric patients: A review of the literature.

    Science.gov (United States)

    Skórska, Małgorzata

    2014-03-01

    A literature review was undertaken to identify current TSEB therapy in pediatric patients. Total skin electron beam (TSEB) therapy is a method of irradiation with low energy electron beam dedicated to patients who have superficial skin lesions all over their body. Such skin malignancies are sparse among adults and even more uncommon with pediatric population. In this study, all reported case reports were summed up with a special emphasis on techniques used, doses prescribed and special shielding of critical organs. Moreover, potential problems that were encountered during TSEB irradiation of very young patients were depicted. The literature has described only seven case reports of children undergoing TSEB therapy. Most of them were infants; however, two adolescents were also treated. For all infants, general anesthesia was provided to allow safe and accurate TSEB irradiation. The prescribed dose varied from 16 Gy to 28 Gy depending on the irradiation schedule and patient condition. Usually, boost fields were applied to the scalp and perineum. Typical shields for fingernails, toenails and lenses were usually used. This paper revealed that TSEB therapy may be considered as a palliative treatment for pediatric patients with leukemia cutis. However, its role is still unclear and should be further investigated.

  9. Coupled-Multiplier Accelerator Produces High-Power Electron Beams for Industrial Applications

    Science.gov (United States)

    Hatridge, M.; McIntyre, P.; Roberson, S.; Sattarov, A.; Thomas, E.; Meitzler, Charles

    2003-08-01

    The coupled multiplier is a new approach to efficient generation of MeV d.c. power for accelerator applications. High voltage is produced by a series of modules, each of which consists of a high-power alternator, step-up transformer, and 3-phase multiplier circuit. The alternators are connected mechanically along a rotating shaft, and connected by insulating flexible couplers. This approach differs from all previous d.c. technologies in that power is delivered to the various stages of the system mechanically, rather than through capacitive or inductive electrical coupling. For this reason the capital cost depends linearly on required voltage and power, rather than quadratically as with conventional technologies. The CM technology enables multiple electron beams to be driven within a common supply and insulating housing. MeV electron beam is extremely effective in decomposing organic contaminants in water. A 1 MeV, 100 kW industrial accelerator using the CM technology has been built and is being installed for treatment of wastewater at a petrochemical plant.

  10. Evaluation of the Efficiency of Electron Beam Irradiation for Removal of Humic Acid from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Mohammad hasan Ehrampoosh

    2017-05-01

    Full Text Available Background: Humic acids (HAs have adverse effects on the environment; therefore, they should be removed from the water and wastewater. The aim of this study was to evaluate the efficiency of the electron beam irradiation for removal of humic acid from aqueous solutions. Methods: Humic acid was purchased from Sigma-Aldrich Company. After preparation of stock solution in alkaline condition, different concentrations of humic acid (10, 25 and 50 mg were prepared. Study has done at pH= 8 and in different dose rates of 1, 3, 6, 9 and 15 kGy. Then initial absorption of samples was measured at 254 nm using UV-Visible spectrophotometer before and after the irradiation. Excel and SPSS Ver. 18 were used for analyzing the data and drawing graphs. Results: The results of this study showed that by increasing adsorbed dose from 1 to 15 kGy, the efficiency of HA removal increased and by increasing humic acid concentration from 10 to 50 mg/L, the removal efficiency of humic acid decreased. The results of the kinetic study showed that irradiation of humic acid followed pseudo second-order reaction. Conclusion: It can be concluded that electron beam irradiation can be a useful technology for the treatment of environmental samples contaminated by humic acid.

  11. Combined effects of microwaves, electron beams and polyfunctional monomers on rubber vulcanization.

    Science.gov (United States)

    Manaila, Elena; Martin, Diana; Stelescu, Daniela Zuga; Craciun, Gabriela; Ighigeanu, Daniel; Matei, Constantin

    2009-01-01

    This paper presents comparative results obtained by conventional vulcanization with benzoyl peroxide (CV-BP), separate electron beam vulcanization (EB-V) and simultaneous electron beam and microwave vulcanization (EB+MW-V) applied to two kind of rubber samples: EVA (ethylene vinyl acetate) rubber-sample (EVA-sample) and EPDM (ethylene-propylene terpolymer) rubber-sample (EPDM-sample). The EVA-samples contain 61.54% EVA Elvax 260, 30.77% carbon black, 1.85% TAC (triallylcyanurate) polyfunctional monomer and 5.84% filler (zinc oxide, stearic acid, polyethylene glycol and antioxidant). The EPDM-samples contain 61.54% EPDM Nordel 4760, 30.77% carbon black, 1.85% TMPT (trimethylopropane trimethacrylate) polyfunctional monomer and 5.84% filler (zinc oxide, stearic acid, polyethylene glycol and antioxidant). The rubber samples designed for different vulcanization methods were obtained from raw rubber mixtures, as compressed sheets of 2 mm in the polyethylene foils to minimize oxidation. For EB and EB + MW treatments the sheets were cut in rectangular shape 0.15 x 0.15 m2. The physical properties of samples obtained by CV-BP EV-Vand EB + MW-V methods were evaluated by measuring the tearing strength, residual elongation, elongation at break, tensile strength, 300% modulus, 100% modulus, elasticity and hardness. The obtained results demonstrate an improvement of rubber several properties obtained by EB and EB + MW processing as compared to classical procedure using benzoyl peroxide.

  12. Technical feasibility for electron beam application on maize seeds disinfection for maize cultivation in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Zago, Claudia [Proenco Brasil Ltda. (Brazil)]. E-mail: clauzago@uol.com.br; Rela, Paulo Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (brazil). Centro de Tecnologia das Radiacoes]. E-mail: prela@ipen.br

    2007-07-01

    Among the man made activities agriculture plays a fundamental rule on the interference with environment; new alternatives for clean technologies are being searched in order to reduce the impact and degradation of the environment. This work presents a feasibility study to implement in Brazil a technology using electron beam treatment to disinfect maize seeds avoiding the spoilage from pathogens microorganisms. This technology was developed in Germany by Fraunhofer Institut FEP (Dresden) and the private company Schmidt-Seeger AG. It was patented as 'e-ventus'. Concerning to the technical feasibility it shows to be quite useful due to the results of the experiments performed in other countries with maize seeds and properly for the large amount to be treated in the country. Under the environmental management it is quite advantageous when compared with the traditional technology that uses chemical seed dressing agents. Nevertheless for a large scale commercial application it is necessary a cost analyse comparison study between the traditional technology and the alternative using electron beam. (author)

  13. Use of plasma polymerization to improve adhesion strength in carbon fiber composites cured by electron beam.

    Science.gov (United States)

    Vautard, Frédéric; Fioux, Philippe; Vidal, Loïc; Siffer, Frédéric; Roucoules, Vincent; Schultz, Jacques; Nardin, Michel; Defoort, Brigitte

    2014-02-12

    Maleic anhydride plasma polymer was deposited at the surface of carbon fibers and functionalized with vinyl and thiol groups to improve its adhesion strength with an acrylate matrix cured by an electron beam. A characterization of the fiber surface properties was done before and after coating (topography, surface chemistry, and surface energy). Sharp improvements of the interfacial shear strength (+ 120%), measured by a micromechanical test derived from the pull-out test, were obtained and, to the best of our knowledge, never reported before. The values were close to the ones obtained with a thermal cure. The comparison of this approach with other types of surface treatments (oxidation, grafting of coupling agents) enabled the establishment of a general strategy for the improvement of the interfacial adhesion in carbon fiber composites cured by an electron beam and potentially the improvement of their mechanical properties. This strategy is based on a high surface density of functionalities that are generating covalent bonding during the polymerization of the matrix and on the insertion of a polymer layer strongly attached to the fiber surface and acting as a buffer between the fiber surface and the matrix to counteract the generation of stress in the interphase.

  14. Microstructure Modifications and Associated Corrosion Improvements in GH4169 Superalloy Treated by High Current Pulsed Electron Beam

    OpenAIRE

    Su, Yichang; Li, Guangyu; Niu, Liyuan; Yang, Shengzhi; Cai, Jie; Guan, Qingfeng

    2015-01-01

    The surface of the nickel-based superalloy GH4169 was subjected to high-current pulsed electron beam (HCPEB) treatment. The microstructural morphologies of the material were analysed by means of optical microscope (OP), scanning electron microscope (SEM), and transmission electron microscope (TEM). The results reveal that the irradiated surface was remelted and many craters were formed. The density of craters decreased with the increment of HCPEB pulses. After 20-pulsed HCPEB irradiation, nan...

  15. Tomography of the electron beam transverse phase space at PITZ

    Energy Technology Data Exchange (ETDEWEB)

    Asova, Galina

    2013-09-15

    The operation of a Free Elector Laser, FEL, requires high energy, high peak current electron beams with small transverse emittance. In the contemporary FELs, the electron beam is passed through a periodic magnetic structure - an undulator - which modifies the straight beam trajectory into a sinusoidal one, where FEL light is generated at each bend. According to the energy, the transverse emittance and the peak current of the beam and the parameters of the undulator, FEL radiation with wavelength in the range of nano- to micrometers can be generated. Studies and development of FELs are done all over the world. The Free electron LASer in Hamburg, FLASH, and the international European X-ray FEL, XFEL, in Hamburg, Germany, are two leading projects of the Deutsches Elektronen SYnchrotron, DESY. Part of the research program on FELs in DESY is realized in Zeuthen within the project Photo-Injector Test Facility at DESY in Zeuthen, PITZ. PITZ is an international collaboration including Germany, Russia, Italy, France, Bulgaria, Thailand, United Kingdom. The Institute of Nuclear Research and Nuclear Energy, INRNE, at the Bulgarian Academy of Sciences participates from bulgarian side. PITZ studies and optimizes the photo-injectors for FLASH and the XFEL. The research program emphasizes on detailed measurements of the transverse phase-space density distribution. Until 2010 the single slit scan technique has been used to measure the beam transverse distributions. At the end of 2010 a module for tomographic diagnostics has been installed which extends the possibilities of PITZ to measure simultaneously the two transverse planes of a single micropulse with improved signal-to-noise ratio. The difficult conditions of low emittance for high bunch charge and low energy make the operation of the module challenging. This thesis presents the design considerations for the tomography module, a number of reconstruction algorithms and their applicability to limited data sets, the influence

  16. Disabling CNT Electronic Devices by Use of Electron Beams

    Science.gov (United States)

    Petkov, Mihail

    2008-01-01

    Bombardment with tightly focused electron beams has been suggested as a means of electrically disabling selected individual carbon-nanotubes (CNTs) in electronic devices. Evidence in support of the suggestion was obtained in an experiment in which a CNT field-effect transistor was disabled (see figure) by focusing a 1-keV electron beam on a CNT that served as the active channel of a field-effect transistor (FET). Such bombardment could be useful in the manufacture of nonvolatile-memory circuits containing CNT FETs. Ultimately, in order to obtain the best electronic performances in CNT FETs and other electronic devices, it will be necessary to fabricate the devices such that each one contains only a single CNT as an active element. At present, this is difficult because there is no way to grow a single CNT at a specific location and with a specific orientation. Instead, the common practice is to build CNTs into electronic devices by relying on spatial distribution to bridge contacts. This practice results in some devices containing no CNTs and some devices containing more than one CNT. Thus, CNT FETs have statistically distributed electronic characteristics (including switching voltages, gains, and mixtures of metallic and semiconducting CNTs). According to the suggestion, by using a 1-keV electron beam (e.g., a beam from a scanning electron microscope), a particular nanotube could be rendered electrically dysfunctional. This procedure could be repeated as many times as necessary on different CNTs in a device until all of the excess CNTs in the device had been disabled, leaving only one CNT as an active element (e.g., as FET channel). The physical mechanism through which a CNT becomes electrically disabled is not yet understood. On one hand, data in the literature show that electron kinetic energy >86 keV is needed to cause displacement damage in a CNT. On the other hand, inasmuch as a 1-keV beam focused on a small spot (typically a few tens of nanometers wide

  17. Numerical Simulation of the Microtron Electron Beam Absorption by the Modified ABS-Plastic

    Science.gov (United States)

    Stuchebrov, S. G.; Miloichikova, I. A.; Melnikov, A. L.; Pereverzeva, M. A.

    2016-01-01

    Each specific task of the electron beam application imposes requirements for the beam profile and shape. One of the methods allows achieving high accuracy and low cost of the filters production is the 3D print method. The required properties of the electron beam interaction with the material can be achieved by using the modified plastic filaments. In this paper, the results of the model creation of the electron beams interaction with the ABS-plastic doped with different concentrations are presented. The depth dose distributions of the electron beam in the modified ABS-plastic are sown. The electron beam profiles and the electron beam distribution in the modified ABS-plastic are illustrated.

  18. Electron beam mediated synthesis of grapheme-based nano hybrids for energy storage applications

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Seungmin [Kyungpook National Univ., Taegu (Korea, Republic of)

    2013-07-01

    A new synthetic strategy for preparing nanoporous materials was developed using an electron beam irradiation technique. Graphene-based nanosheets were hybridized with nickel nanoparticles to fabricate flexible delaminated structures for energy storage applications. To elucidate the influence of an electron beam irradiation, the resulting hybrids were irradiated by an electron beam with 100-250 kGy doses under atmospheric conditions. According to X-ray diffraction and transmission electron microscopic analysis, graphene nanosheets were randomly reassembled with nickel nanoparticles without any self-restacking into the layered phase. X-ray absorption spectroscopic analysis revealed that nickel particles in the hybrid materials maintained their nanosized nature even after an electron beam irradiation. The energy storage performances of electron beam-irradiated samples were superior to those of starting materials, highlighting the effectiveness of an electron beam irradiation.

  19. Use of beam deflection to control an electron beam wire deposition process

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hofmeister, William H. (Inventor); Hafley, Robert A. (Inventor)

    2013-01-01

    A method for controlling an electron beam process wherein a wire is melted and deposited on a substrate as a molten pool comprises generating the electron beam with a complex raster pattern, and directing the beam onto an outer surface of the wire to thereby control a location of the wire with respect to the molten pool. Directing the beam selectively heats the outer surface of the wire and maintains the position of the wire with respect to the molten pool. An apparatus for controlling an electron beam process includes a beam gun adapted for generating the electron beam, and a controller adapted for providing the electron beam with a complex raster pattern and for directing the electron beam onto an outer surface of the wire to control a location of the wire with respect to the molten pool.

  20. Emittance Reduction between EBIS LINAC and Booster by Electron Beam Cooling; Is Single Pass Cooling Possible?

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch,A.

    2008-04-01

    Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in less than one meter.

  1. PLASMA EMISSION BY COUNTER-STREAMING ELECTRON BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Ziebell, L. F.; Petruzzellis, L. T.; Gaelzer, R. [Instituto de Física, UFRGS, Porto Alegre, RS (Brazil); Yoon, P. H. [Institute for Physical Science and Technology, University of Maryland, College Park, MD (United States); Pavan, J., E-mail: luiz.ziebell@ufrgs.br, E-mail: yoonp@umd.edu, E-mail: joel.pavan@ufpel.edu.br [Instituto de Física e Matemática, UFPel, Pelotas, RS (Brazil)

    2016-02-10

    The radiation emission mechanism responsible for both type-II and type-III solar radio bursts is commonly accepted as plasma emission. Recently Ganse et al. suggested that type-II radio bursts may be enhanced when the electron foreshock geometry of a coronal mass ejection contains a double hump structure. They reasoned that the counter-streaming electron beams that exist between the double shocks may enhance the nonlinear coalescence interaction, thereby giving rise to more efficient generation of radiation. Ganse et al. employed a particle-in-cell simulation to study such a scenario. The present paper revisits the same problem with EM weak turbulence theory, and show that the fundamental (F) emission is not greatly affected by the presence of counter-streaming beams, but the harmonic (H) emission becomes somewhat more effective when the two beams are present. The present finding is thus complementary to the work by Ganse et al.

  2. Pelletron-based MeV-range electron beam recirculation

    CERN Document Server

    Crawford, A C; Sharapa, A N; Shemyakin, A

    1999-01-01

    In this paper we describe the successful recirculation of a DC electron beam at energies 1-1.5 MeV and currents up to 0.7 A with typical relative losses of 5-20x10 sup - sup 6. Currents of 200 mA were maintained for periods of up to five hours without a single breakdown. We found that the aperture-limiting diaphragm in the gun anode significantly increased the stability of the recirculation. We also found that the stability depended strongly on vacuum pressure in the beamline. The performance of the collector with transverse magnetic fields was found to be adequate for beam currents up to 0.6 A, which is in agreement with our low-energy bench test results. (author)

  3. Spin-valley splitting of electron beam in graphene

    Directory of Open Access Journals (Sweden)

    Yu Song

    2016-11-01

    Full Text Available We study spatial separation of the four degenerate spin-valley components of an electron beam in a EuO-induced and top-gated ferromagnetic/pristine/strained graphene structure. We show that, in a full resonant tunneling regime for all beam components, the formation of standing waves can lead sudden phase jumps ∼−π and giant lateral Goos-Hänchen shifts as large as the transverse beam width, while the interplay of the spin and valley imaginary wave vectors in the modulated regions can lead differences of resonant angles for the four spin-valley flavors, manifesting a spin-valley beam splitting effect. The splitting effect is found to be controllable by the gating and strain.

  4. Prospects for electron beam aberration correction using sculpted phase masks

    Energy Technology Data Exchange (ETDEWEB)

    Shiloh, Roy, E-mail: royshilo@post.tau.ac.il; Remez, Roei; Arie, Ady

    2016-04-15

    Technological advances in fabrication methods allowed the microscopy community to take incremental steps towards perfecting the electron microscope, and magnetic lens design in particular. Still, state of the art aberration-corrected microscopes are yet 20–30 times shy of the theoretical electron diffraction limit. Moreover, these microscopes consume significant physical space and are very expensive. Here, we show how a thin, sculpted membrane is used as a phase-mask to induce specific aberrations into an electron beam probe in a standard high resolution TEM. In particular, we experimentally demonstrate beam splitting, two-fold astigmatism, three-fold astigmatism, and spherical aberration. - Highlights: • Thin membranes can be used as aberration correctors in electron columns. • We demonstrate tilt, twofold-, threefold-astigmatism, and spherical aberrations. • Experimental and physical-optics simulation results are in good agreement. • Advantages in cost, size, nonmagnetism, and nearly-arbitrary correction.

  5. Prospects for electron beam aberration correction using sculpted phase masks.

    Science.gov (United States)

    Shiloh, Roy; Remez, Roei; Arie, Ady

    2016-04-01

    Technological advances in fabrication methods allowed the microscopy community to take incremental steps towards perfecting the electron microscope, and magnetic lens design in particular. Still, state of the art aberration-corrected microscopes are yet 20-30 times shy of the theoretical electron diffraction limit. Moreover, these microscopes consume significant physical space and are very expensive. Here, we show how a thin, sculpted membrane is used as a phase-mask to induce specific aberrations into an electron beam probe in a standard high resolution TEM. In particular, we experimentally demonstrate beam splitting, two-fold astigmatism, three-fold astigmatism, and spherical aberration. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Non-invasive measurments of intense relativistic electron beam size

    Science.gov (United States)

    Ekdahl, Carl; McCuistian, Trent; Moir, David; Rodriguez, Patrick; Broste, William; Johnson, Jeff

    2000-10-01

    To understand relativistic electron beam transport dynamics the size of the beam is often measured using invasive techniques such as imaging the Cerenkov or OTR light emitted from a screen inserted into the beam. These techniques would completely disrupt the DARHT 2 beam, so we are developing a non-invasive method using diamagnetic loops. We show that through conservation of canonical angular momentum the RMS radius of the beam can be found by measuring the magnetic flux excluded by the diamagnetic beam. Furthermore, this measurement is shown to be independent of the details of the beam radial current profile for DARHT 2 parameters. We present results from our test and calibration experiments, as well as results of beam radius measurements on the 20-MeV DARHT 1 accelerator.

  7. Electron beam processing of fresh produce - A critical review

    Science.gov (United States)

    Pillai, Suresh D.; Shayanfar, Shima

    2018-02-01

    To meet the increasing global demand for fresh produce, robust processing methods that ensures both the safety and quality of fresh produce are needed. Since fresh produce cannot withstand thermal processing conditions, most of common safety interventions used in other foods are ineffective. Electron beam (eBeam) is a non-thermal technology that can be used to extend the shelf life and ensure the microbiological safety of fresh produce. There have been studies documenting the application of eBeam to ensure both safety and quality in fresh produce, however, there are still unexplored areas that still need further research. This is a critical review on the current literature on the application of eBeam technology for fresh produce.

  8. Electron beam machining using rotating and shaped beam power distribution

    Science.gov (United States)

    Elmer, J.W.; O`Brien, D.W.

    1996-07-09

    An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.

  9. Predicting Mesoscale Microstructural Evolution in Electron Beam Welding

    Science.gov (United States)

    Rodgers, T. M.; Madison, J. D.; Tikare, V.; Maguire, M. C.

    2016-05-01

    Using the kinetic Monte Carlo simulator, Stochastic Parallel PARticle Kinetic Simulator, from Sandia National Laboratories, a user routine has been developed to simulate mesoscale predictions of a grain structure near a moving heat source. Here, we demonstrate the use of this user routine to produce voxelized, synthetic, three-dimensional microstructures for electron-beam welding by comparing them with experimentally produced microstructures. When simulation input parameters are matched to experimental process parameters, qualitative and quantitative agreement for both grain size and grain morphology are achieved. The method is capable of simulating both single- and multipass welds. The simulations provide an opportunity for not only accelerated design but also the integration of simulation and experiments in design such that simulations can receive parameter bounds from experiments and, in turn, provide predictions of a resultant microstructure.

  10. Automation of the electron-beam welding process

    Science.gov (United States)

    Koleva, E.; Dzharov, V.; Kardjiev, M.; Mladenov, G.

    2016-03-01

    In this work, the automatic control is considered of the vacuum and cooling systems of the located in the IE-BAS equipment for electron-beam welding, evaporation and surface modification. A project was elaborated for the control and management based on the development of an engineering support system using existing and additional technical means of automation. Optimization of the indicators, which are critical for the duration of reaching the working regime and stopping the operation of the installation, can be made using experimentally obtained transient characteristics. The automation of the available equipment aimed at improving its efficiency and the repeatability of the obtained results, as well as at stabilizing the process parameters, should be integrated in an Engineering Support System which, besides the operator supervision, consists of several subsystems for equipment control, data acquisition, information analysis, system management and decision-making support.

  11. The electron beam welding of dissimilar materials - case study

    Science.gov (United States)

    Munteanu, A.

    2016-11-01

    The modalities to realize the welding workpieces are multiple. The electron beam welding is one of them. One can weld two different types of materials that give the possibility to reduce the cost of workpiece, if the active part is realised of rich materials welded on components with inferior phisico-mecanical characteristics. The procedure provides great flexibility to the product designs through efficient use of each type of material. So this aspects lead to the necessity to join dissimilar metals. Different tables are given in the specific literature regarding the possible combination. Conflicts may arise by the compromises required for to the optimum heat control of the two dissimilar materials used. But nowadays, more and more frequently are meet the welding of dissimilar metals, thus, the objective of this article is to provide information regarding the particular case of welding between stainless steel and copper without the filler material use.

  12. Electron beam machining using rotating and shaped beam power distribution

    Science.gov (United States)

    Elmer, John W.; O'Brien, Dennis W.

    1996-01-01

    An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.

  13. Fundamental edge broadening effects during focused electron beam induced nanosynthesis

    Directory of Open Access Journals (Sweden)

    Roland Schmied

    2015-02-01

    Full Text Available The present study explores lateral broadening effects of 3D structures fabricated through focused electron beam induced deposition using MeCpPt(IVMe3 precursor. In particular, the scaling behavior of proximity effects as a function of the primary electron energy and the deposit height is investigated through experiments and validated through simulations. Correlated Kelvin force microscopy and conductive atomic force microscopy measurements identified conductive and non-conductive proximity regions. It was determined that the highest primary electron energies enable the highest edge sharpness while lower energies contain a complex convolution of broadening effects. Moreover, it is demonstrated that intermediate energies lead to even more complex proximity effects that significantly reduce lateral edge sharpness and thus should be avoided if desiring high lateral resolution.

  14. Calculation of Electron Beam Potential Energy from RF Photocathode Gun

    CERN Document Server

    Liu Wan Ming; Power, John G; Wang, Haitao

    2005-01-01

    In this paper, we consider the contribution of potential energy to beam dynamics as simulated by PARMELA at low energies (10 - 30MeV). We have developed a routine to calculate the potential energy of the relativistic electron beam using the static coulomb potential in the rest frame (first order approximation as in PARMELA). We found that the potential energy contribution to the beam dynamics could be very significant, particularly with high charge beams generated by an RF photocathode gun. Our results show that when the potential energy is counted correctly and added to the kinetic energy from PARMELA, the total energy is conserved. Simulation results of potential and kinetic energies for short beams (~1 mm) at various charges (1 - 100 nC) generated by a high current RF photocathode gun are presented.

  15. Vaccine Biotechnology by Accelerated Electron Beam and Microwave Irradiation

    Science.gov (United States)

    Craciun, Gabriela D.; Togoe, Iulian I.; Tudor, Laurentiu M.; Martin, Diana I.; Manaila, Elena N.; Ighigeanu, Daniel I.; Iacob, Nicusor I.; Oproiu, Constantin V.

    2007-04-01

    A new biotechnology for obtaining a commercial vaccine that contains either Fusobacterium necrophorum (F.n.) exotoxins inactivated by accelerated electron beam (EB) and microwave (MW) irradiation, or exotoxins isolated from F.n. cultures irradiated with EB+MW, is presented. This vaccine is designed for prophylaxis of ruminant infectious pododermatitis (IP) produced by F.n. Also, the research results concerning the effects of combined chemical adjuvant and EB+MW irradiation on F.n. immune capacity are discussed. The vaccine's efficacy will be tested in ruminant farms in which IP evolves. It is expected that this new vaccine to offer a better protection, more than 60%, which is the best presently obtained result in ruminant farms.

  16. Initial commissioning results with the NSCL Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, S.; Kittimanapun, K.; Lapierre, A.; Leitner, D.; Ottarson, J.; Portillo, M. [National Superconducting Cyclotron Laboratory, NSCL, Michigan State University, East Lansing, Michigan 48824 (United States); Bollen, G. [National Superconducting Cyclotron Laboratory, NSCL, Michigan State University, East Lansing, Michigan 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824 (United States); Lopez-Urrutia, J. R. Crespo [Max-Planck Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Kester, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany)

    2012-02-15

    The ReA reaccelerator is being added to the National Superconducting Cyclotron Laboratory (NSCL) fragmentation facility in order to provide exotic rare-isotope beams, not available at the Isotope Separation On-Line facilities, in the several-MeV/u energy range. The first stage of the NSCL reaccelerator complex, consisting of an EBIT charge breeder, a room-temperature radiofrequency quadrupole (RFQ) accelerator, and superconducting linear accelerator modules, has been completed and is being put into operation. Commissioning of the EBIT has started by extracting charge-bred residual gas ions, ions created from a Ne gas jet directed across the EBIT's electron beam and ions captured from an external test ion source. Charge-bred ions from the Ne gas jet have been extracted as a pulse and accelerated through the RFQ and the two cryomodules.

  17. Ion optics of RHIC electron beam ion source.

    Science.gov (United States)

    Pikin, A; Alessi, J; Beebe, E; Kponou, A; Okamura, M; Raparia, D; Ritter, J; Tan, Y; Kuznetsov, G

    2012-02-01

    RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  18. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  19. Plasma response to the injection of an electron beam

    Science.gov (United States)

    Singh, N.; Schunk, R. W.

    1984-01-01

    The results of Vlasov-Poisson-solver numerical simulations of the detailed temporal response of a Maxwellian plasma to the sudden injection of an electron beam are presented in graphs and maps and discussed. Phenomena characterized include ion bursts, electron shocks and holes, plasma heating and expulsion, density gradients; cavitons, deep-density-front and solitary-pulse propagation down the density gradient, and Bunemann-mode excitation leading to formation of a virtual cathode and double layers which are at first monotonic or have low-potential-side dips or high-potential-side bumps and become strong as the electron-current density decreases. The strength of the double layer is found to be roughly proportional to the beam energy.

  20. Double layer propagation in experiments with electron beam injection

    Science.gov (United States)

    Bruskin, L. G.; Khazanov, G. V.

    1993-01-01

    Electron beam injection into a plasma is investigated using the analytical inverted Bernstein-Green-Kruskal method. Particle number and momentum conservation laws are applied to evaluate the propagation velocity and potential drop on the leading edge of the beam. Electric potential is supposed to be monotonic, thus the leading front has a double-layer-like structure. For the case of cold particles, analytical expressions for the double layer velocity and potential drop are obtained. It is pointed out that double layer velocity differs from the initial electron speed: even for weak beams a noticeable deceleration takes place. Strong beams are found incapable of penetrating into plasma - their propagation velocity is very small. Ambient electrons undergo a considerable acceleration forming a return current which neutralizes the injector. Possible instability of the distribution functions is discussed.

  1. Impact of electron beam irradiation on fish gelatin film properties.

    Science.gov (United States)

    Benbettaïeb, Nasreddine; Karbowiak, Thomas; Brachais, Claire-Hélène; Debeaufort, Frédéric

    2016-03-15

    The objective of this work was to display the effect of electron beam accelerator doses on properties of plasticized fish gelatin film. Electron spin resonance indicates free radical formation during irradiation, which might induce intermolecular cross-linking. Tensile strength for gelatin film significantly increases after irradiation (improved by 30% for 60 kGy). The vapour permeability is weakly affected by irradiation. Surface tension and its polar component increase significantly and are in accordance with the increase of wettability. So, irradiation may change the orientation of polar groups of gelatin at the film surface and crosslink the hydrophobic amino acids. No modification of the crystallinity of the film is observed. These findings suggest that if structure changes, it only occurs in the amorphous phase of the gelatin matrix. It is also observed that irradiation enhances the thermal stability of the gelatin film, by increasing the glass transition temperature and the degradation temperature. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Modelling focused electron beam induced deposition beyond Langmuir adsorption

    Directory of Open Access Journals (Sweden)

    Dédalo Sanz-Hernández

    2017-10-01

    Full Text Available In this work, the continuum model for focused electron beam induced deposition (FEBID is generalized to account for multilayer adsorption processes. Two types of adsorption energies, describing both physisorption and spontaneous chemisorption, are included. Steady state solutions under no diffusion are investigated and compared under a wide range of conditions. The different growth regimes observed are fully explained by relative changes in FEBID characteristic frequencies. Additionally, we present a set of FEBID frequency maps where growth rate and surface coverage are plotted as a function of characteristic timescales. From the analysis of Langmuir, as well as homogeneous and heterogeneous multilayer maps, we infer that three types of growth regimes are possible for FEBID under no diffusion, resulting into four types of adsorption isotherms. We propose the use of these maps as a powerful tool for the analysis of FEBID processes.

  3. Electron-beam deposition of vanadium dioxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Marvel, R.E.; Appavoo, K. [Vanderbilt University, Interdisciplinary Materials Science Program, Nashville, TN (United States); Choi, B.K. [Vanderbilt University, Department of Electrical Engineering and Computer Science, Nashville, TN (United States); Nag, J. [Vanderbilt University, Department of Physics and Astronomy, Nashville, TN (United States); Haglund, R.F. [Vanderbilt University, Interdisciplinary Materials Science Program, Nashville, TN (United States); Vanderbilt University, Institute for Nanoscale Science and Engineering, Nashville, TN (United States); Vanderbilt University, Department of Physics and Astronomy, Nashville, TN (United States)

    2013-06-15

    Developing a reliable and efficient fabrication method for phase-transition thin-film technology is critical for electronic and photonic applications. We demonstrate a novel method for fabricating polycrystalline, switchable vanadium dioxide thin films on glass and silicon substrates and show that the optical switching contrast is not strongly affected by post-processing annealing times. The method relies on electron-beam evaporation of a nominally stoichiometric powder, followed by fast annealing. As a result of the short annealing procedure we demonstrate that films deposited on silicon substrates appear to be smoother, in comparison to pulsed laser deposition and sputtering. However, optical performance of e-beam evaporated film on silicon is affected by annealing time, in contrast to glass. (orig.)

  4. FEL indulators with the hollow-ring electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Epp, V.; Bordovitsyn, V. [Tomsk State Univ. (Russian Federation); Kozhevnikov, A. [Tomsk Pedagogical Institute (Russian Federation)] [and others

    1995-12-31

    A conceptual design of undulators with a modulated longitudinal magnetic field is proposed. The magnetic field is created by use of a solenoid with axis coincident with the electron beam axis. In order to modulate the magnetic field we propose an insertion of a row of alternating ferromagnetic and superconducting diaphragms in line with electron beam. The simulation of two-dimensional distribution of the magnetic field in the plane containing undulator axis was made using the computer code {open_quotes}Mermaid{close_quotes}. The magnetic field was analysed as a function of the system geometry. The dependence on the spacing l between superconducting diaphragms, inner a and outer b radii of the last ones is investigated. Two versions of the device are considered: with ferromagnetic rings made of magnetically soft material placed between the superconducting diaphragms and without them. It is shown that the field modulation depth increases with ratio of b/l and can exceed 50% in case of the ferromagnetic insertions. An approximate analytical calculation of the magnetic field distribution is performed as follows. The axial-symmetrical magnetic field can be defined by the vector potential with only one nonzero component A(r,{phi}) where r and {phi} are the cylindrical coordinates. The solution of the Laplace`s equation is found under the assumption that the magnetic field is infinitely extended and periodic along the z-axis. The boundary conditions are defined by the undulator design. The result is used for the calculation of the particle dynamics and for the investigations of the trajectory stability. The spectral and angular distribution of the radiation emitted from the described systems is found. The estimations show that the proposed design allows to create relatively high magnitude of the magnetic field (up to 1 T) with a short period about 1 cm or less.

  5. Velocity bunching of high-brightness electron beams

    Directory of Open Access Journals (Sweden)

    S. G. Anderson

    2005-01-01

    Full Text Available Velocity bunching has been recently proposed as a tool for compressing electron beam pulses in modern high brightness photoinjector sources. This tool is familiar from earlier schemes implemented for bunching dc electron sources, but presents peculiar challenges when applied to high current, low emittance beams from photoinjectors. The main difficulty foreseen is control of emittance oscillations in the beam in this scheme, which can be naturally considered as an extension of the emittance compensation process at moderate energies. This paper presents two scenarios in which velocity bunching, combined with emittance control, is to play a role in nascent projects. The first is termed ballistic bunching, where the changing of relative particle velocities and positions occur in distinct regions, a short high gradient linac, and a drift length. This scenario is discussed in the context of the proposed ORION photoinjector. Simulations are used to explore the relationship between the degree of bunching, and the emittance compensation process. Experimental measurements performed at the UCLA Neptune Laboratory of the surprisingly robust bunching process, as well as accompanying deleterious transverse effects, are presented. An unanticipated mechanism for emittance growth in bends for highly momentum chirped beam was identified and studied in these experiments. The second scenario may be designated as phase space rotation, and corresponds closely to the recent proposal of Ferrario and Serafini. Its implementation for the compression of the electron beam pulse length in the PLEIADES inverse Compton scattering (ICS experiment at LLNL is discussed. It is shown in simulations that optimum compression may be obtained by manipulation of the phases in low gradient traveling wave accelerator sections. Measurements of the bunching and emittance control achieved in such an implementation at PLEIADES, as well as aspects of the use of velocity-bunched beam directly

  6. VELOCITY BUNCHING OF HIGH-BRIGHTNESS ELECTRON BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S G; Musumeci, P; Rosenzweig, J B; Brown, W J; England, R J; Ferrario, M; Jacob, J S; Thompson, M C; Travish, G; Tremaine, A M; Yoder, R

    2004-10-15

    Velocity bunching has been recently proposed as a tool for compressing electron beam pulses in modern high brightness photoinjector sources. This tool is familiar from earlier schemes implemented for bunching dc electron sources, but presents peculiar challenges when applied to high current, low emittance beams from photoinjectors. The main difficulty foreseen is control of emittance oscillations in the beam in this scheme, which can be naturally considered as an extension of the emittance compensation process at moderate energies. This paper presents two scenarios in which velocity bunching, combined with emittance control, is to play a role in nascent projects. The first is termed ballistic bunching, where the changing of relative particle velocities and positions occur in distinct regions, a short high gradient linac, and a drift length. This scenario is discussed in the context of the proposed ORION photoinjector. Simulations are used to explore the relationship between the degree of bunching, and the emittance compensation process. Experimental measurements performed at the UCLA Neptune Laboratory of the surprisingly robust bunching process, as well as accompanying deleterious transverse effects, are presented. An unanticipated mechanism for emittance growth in bends for highly momentum chirped beam was identified and studied in these experiments. The second scenario may be designated as phase space rotation, and corresponds closely to the recent proposal of Ferrario and Serafini. Its implementation for the compression of the electron beam pulse length in the PLEIADES inverse Compton scattering (ICS) experiment at LLNL is discussed. It is shown in simulations that optimum compression may be obtained by manipulation of the phases in low gradient traveling wave accelerator sections. Measurements of the bunching and emittance control achieved in such an implementation at PLEIADES, as well as aspects of the use of velocity-bunched beam directly in ICS experiments

  7. Microstructure and hardness studies of electron beam melted surface of mild steel

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, M., E-mail: maqomer@yahoo.com [Physics Division, Pakistan Institute of Nuclear Science and Technology, P.O. Nilore, Islamabad (Pakistan); Haq, M.A.; Ahmed, Ejaz; Ali, G.; Akhter, J.I. [Physics Division, Pakistan Institute of Nuclear Science and Technology, P.O. Nilore, Islamabad (Pakistan); Iqbal, M. [National Institute of Lasers and Optronics, Nilore, Islamabad (Pakistan)

    2009-04-15

    Electron beam surface melting of mild steel with the addition of Ni and SiC is carried out to improve its surface properties. Microstructure of the electron beam molten surface is characterized by scanning electron microscope. Phases are determined using energy dispersive spectroscopy and X-ray diffraction techniques. During electron beam melting SiC dissociated partially, interacted with liquid alloy and resulted in martensitic phases after solidification. Maximum hardness is achieved in electron beam molten zone. It is concluded that the formation of martensitic phase and the presence of Si and Ni in the solid solution are responsible for increase in hardness in the molten zone.

  8. First application of total skin electron beam irradiation in Greece: setup, measurements and dosimetry.

    Science.gov (United States)

    Platoni, K; Diamantopoulos, S; Panayiotakis, G; Kouloulias, V; Pantelakos, P; Kelekis, N; Efstathopoulos, E

    2012-04-01

    Total Skin Electron Beam (TSEB) irradiation is considered as the treatment of choice for cutaneous T-cell lymphoma internationally, for either curative purposes or palliative care. An attempt for the first application of this external radiation therapy technique in Greece took place at the Radiation Therapy Unit of 2(nd) Department of Radiology of University of Athens at University General Hospital "Attikon". TSEB modality was developed on a linear accelerator VARIAN Clinac 2100C. To create a uniform and sufficiently large field (≈200 cm × 80 cm) at SSD=380 cm, two symmetrical 6 MeV electron beams are combined with 17.5° tilts concerning the horizontal direction. An immobilization system was constructed to support patient during treatment and to modulate the composite electron field. Irradiation procedure demands a standing patient that takes, in total, six treatment positions. For the confirmation of treatment suitability and the determination of physical features of the clinical electron field, specific measurements were carried out using a parallel-plate ionization chamber and TLDs at water equivalent plastic and anthropomorphic phantoms. Measurements at the referred conditions showed a homogeneous total field with intensity variation of ±2% in the longitudinal axis and ±4% at horizontal axis. The mean energy of the composite field (E¯(o)) is 3.4 MeV, the most probable energy (E(p,0)) is 4.4 MeV and the half-value depth in water (R(50)) is 1.5 g/cm(2). The maximum X-ray background of the TSEB field is 2.1% at head and feet. The above results lead us to conclude that TSEB treatment using "Six-dual-field" technique can be applied in our department safely. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Comparison of electron beam irradiation with gamma processing for medical packaging materials

    Science.gov (United States)

    Woo, Lecon; Sandford, Craig L.

    2002-03-01

    Ionizing radiation is known to degrade materials and in the meantime is capable of novel property creation. In the medical device industry, sterilization by ionizing radiation has become increasingly popular. In particular, the beta or electron beam irradiation has been adopted along with the traditional gamma radiation from Cobalt or Cesium sources. Of course, the ionizing radiation which disrupts bio-macromolecular structures in bio-burdens can damage polymer chains. Although the mode of radiation interaction is similar, gamma and high-energy electrons differ in several subtle ways: dose rate, sample temperature rise, oxygen availability and treatment duration. We have conducted a comparative study on material interactions due to e-beam irradiation and treatment with gamma. A similarity between the two processes as well as significant differences will be presented.

  10. Texture-Induced Anisotropy in an Inconel 718 Alloy Deposited Using Electron Beam Freeform Fabrication

    Science.gov (United States)

    Tayon, W.; Shenoy, R.; Bird, R.; Hafley, R.; Redding, M.

    2014-01-01

    A test block of Inconel (IN) 718 was fabricated using electron beam freeform fabrication (EBF(sup 3)) to examine how the EBF(sup 3) deposition process affects the microstructure, crystallographic texture, and mechanical properties of IN 718. Tests revealed significant anisotropy in the elastic modulus for the as-deposited IN 718. Subsequent tests were conducted on specimens subjected to a heat treatment designed to decrease the level of anisotropy. Electron backscatter diffraction (EBSD) was used to characterize crystallographic texture in the as-deposited and heat treated conditions. The anisotropy in the as-deposited condition was strongly affected by texture as evidenced by its dependence on orientation relative to the deposition direction. Heat treatment resulted in a significant improvement in modulus of the EBF(sup 3) product to a level nearly equivalent to that for wrought IN 718 with reduced anisotropy; reduction in texture through recrystallization; and production of a more homogeneous microstructure.

  11. Cerrobend collimation effect on electron beams; Efeito de colimacoes de cerrobend em feixes de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Furnari, Laura; Albino, Lucas D.; Ribeiro, Victor A.B.; Santos, Gabriela R., E-mail: laurafurnari@hotmail.com [Universidade de Sao Paulo (InRad/FM/USP), SP (Brazil). Faculdade de Medicina. Hospital das Clinicas. Instituto de Radiologia

    2012-12-15

    The aim of this work was to discuss about the cerrobend collimation effect on clinical electron beams. When a cerrobend collimation is used, both the percentage depth dose (PDD) and the absolute dose that is delivered to the patient changes. It was analyzed how those parameters change and it was evaluated in which cases a correction factor should be applied due to this collimation. It was founded that, when the smallest dimension of the collimation is smaller than the minimum radius to lateral scatter equilibrium, the collimation will change the PDD in such a way that it should take into account in the treatment planning. For one specific collimation usually applied in head and neck treatments, it was found that no correction factor is necessary. (author)

  12. Influence of electron beam welding parameters and metallurgical factors on intergranular liquation cracking susceptibility of cast alloy 718

    Science.gov (United States)

    Woo, Insu; Kang, Chungyun; Nishimoto, Kazutoshi

    2001-07-01

    The factors affecting intergranular liquation cracking susceptibility in electron beam welds were investigated for cast alloy 718. The materials used were as-received plates and heat-treated plates with three different levels of grain size. Liquation cracking susceptibility in HAZ was evaluated by a bead-on-plate test and a restraint/relaxation U-type hot cracking test. The penetrated shapes in the welds were classified into wine cup-like Type W and nail head-like Type N. For a given beam current, Type w and Type N were observed at the lower and higher welding speeds, respectively. Welding defects, i.e., underfills and microcracks were seen in the electron beam welds. Compared with Type W, the liquation cracking was more sensitive for the Type N bead cross sectional shape. Furthermore, it easily occurred at grain boundaries in Region II, i.e., very near the nail head necked part. According to the restraint/relaxation U-type hot cracking test, the liquation cracking susceptibility decreased with decreasing grain size or with homogenization heat treatment. These results suggested that the liquation cracking susceptibility in cast alloy 718 electron beam welds could be improved by using the Type W bead cross sectional shape, a decreasing the grain size and using appropriate heat treatment before welding.

  13. Tailoring laser wakefield accelerated electron beams. An experimental study on the influence of experimental conditions on electron beam parameters

    Energy Technology Data Exchange (ETDEWEB)

    Couperus, Jurjen P.; Koehler, Alexander; Zarini, Omid; Huebl, Axel; Schramm, Ulrich [Institute of Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf (Germany); Technische Universitaet Dresden (Germany); Jochmann, Axel; Debus, Alexander; Irman, Arie [Institute of Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf (Germany)

    2016-07-01

    Laser wakefield acceleration (LWFA) has emerged as a promising concept for the next generation of high energy electron accelerators. In LFWA a high intensity ultrashort laser pulse drives plasma density waves, inducing a high accelerating field gradient in the order of GV/m. To create stable reproducible electron beams, tailoring of experimental parameters like gas density, laser energy and laser pulse duration is required. In this talk we present an overview of our experimental studies with the DRACO (3 J on target, 30 fs) laser on ultrasonic gas-jet targets (He and He-N{sub 2} mixtures). We discuss the influence of experimental parameters on beam parameters like beam charge, shot-to-shot stability and energy distribution, both in the self-injecting bubble regime as well as in the ionisation injection regime.

  14. Clinical application of intensity and energy modulated radiotherapy with photon and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Xiangkui Mu

    2005-01-01

    In modern, advanced radiotherapy (e.g. intensity modulated photon radiotherapy, IMXT) the delivery time for each fraction becomes prolonged to 10-20 minutes compared with the conventional, commonly 2-5 minutes. The biological effect of this prolongation is not fully known. The large number of beam directions in IMXT commonly leads to a large integral dose in the patient. Electrons would reduce the integral dose but are not suitable for treating deep-seated tumour, due to their limited penetration in tissues. By combining electron and photon beams, the dose distributions may be improved compared with either used alone. One obstacle for using electron beams in clinical routine is that there is no available treatment planning systems that optimise electron beam treatments in a similar way as for IMXT. Protons have an even more pronounced dose fall-off, larger penetration depth and less penumbra widening than electrons and are therefore more suitable for advanced radiotherapy. However, proton facilities optimised for advanced radiotherapy are not commonly available. In some instances electron beams may be an acceptable surrogate. The first part of this study is an experimental in vitro study where the situation in a tumour during fractionated radiotherapy is simulated. The effect of the prolonged fraction time is compared with the predictions by radiobiological models. The second part is a treatment planning study to analyse the mixing of electron and photon beams for at complex target volume in comparison with IMXT. In the next step a research version of an electron beam optimiser was used for the improvement of treatment plans. The aim was to develop a method for translating crude energy and intensity matrices for optimised electrons into a deliverable treatment plan without destroying the dose distribution. In the final part, different methods of treating the spinal canal in medulloblastoma were explored in a treatment planning study that was evaluated with

  15. Thermal Processing of Semiconductor Materials Using Soft-Vacuum Electron Beams.

    Science.gov (United States)

    Moore, Cameron Alden

    Electron beams generated in gaseous discharges have been used to perform a variety of thermal treatments germane to semiconductor fabrication. The unique beams employed in these studies are typified by high continuous power (>100 watts per cm^2 of cathode surface), operation in relatively high pressures (0.05-25 Torr), and a wide variety of beam configurations. The ability to extract and direct high power densities lends itself to the heat treatment of silicon-based semiconductor materials. Initial studies examined the rapid thermal processing of various materials and structures using a 7.5 cm. diameter electron beam. Using this source both the annealing of ion implanted single crystal silicon and the formation of titanium disilicide were performed. The repair of damage in single-crystal silicon wafers induced by ions of boron, phosphorus, and arsenic was repaired with minimum redistribution of the dopant profile. The same apparatus was also used to form titanium silicide from both co-deposited and sequentially deposited constituent materials. While low resistivity phases of both materials were obtained, each would exhibit high resistivity behavior as well. Excessive heating of co-deposited films on silicon dioxide induces reactions between the two films, causing oxygen to be incorporated in the silicide. Ti-on-Si structures self-cleanse oxygen from the silicide during formation, in contradiction to known Si-O and Ti-O thermodynamics. A line-source (150 mm x 2 mm) electron beam was used to recrystallize silicon films deposited on oxidized silicon wafers up to 100 mm in diameter. Agglomeration of the silicon while molten was prevented via the use of (i) an encapsulating silicon dioxide film, and (ii) the introduction of appropriate wetting agents into the deposited silicon during wafer preparation. A limiting constraint to the recrystallization of full wafers was the construction of a background heater which can heat the wafer to 1200 ^circC with a uniformity of

  16. Food Irradiation Using Electron Beams and X-Rays

    Science.gov (United States)

    Miller, Bruce

    2003-04-01

    In this presentation we will discuss the technology of food irradiation using electron accelerators. Food irradiation has generally come to describe the use of ionizing radiation to decrease the population of, or prevent the growth of, undesirable biological organisms in food. The many beneficial applications include insect disinfestation, sprouting inhibition, delayed ripening, and the enhanced safety and sterilization of fresh and frozen meat products, seafood, and eggs. With special regard to food safety, bacteria such as Salmonella enteridis, Listeria monocytogenes, Campylobacter jejuni and Escherichia coli serotype O157:H7 are the primary causes of food poisoning in industrialized countries. Ionizing doses in the range of only 1-5 kilogray (kGy) can virtually eliminate these organisms from food, without affecting the food's sensory and nutritional qualities, and without inducing radioactivity. The key elements of an accelerator-based irradiation facility include the accelerator system, a scanning system, and a material handling system that moves the product through the beam in a precisely controlled manner. Extensive radiation shielding is necessary to reduce the external dose to acceptable levels, and a safety system is necessary to prevent accidental exposure of personnel during accelerator operation. Parameters that affect the dose distribution must be continuously monitored and controlled with process control software. The choice of electron beam vs x-ray depends on the areal density (density times thickness) of the product and the anticipated mass throughput. To eliminate nuclear activation concerns, the maximum kinetic energy of the accelerator is limited by regulation to 10 MeV for electron beams, and 5 MeV for x-rays. From penetration considerations, the largest areal density that can be treated by double-sided electron irradiation at 10 MeV is about 8.8 g/cm2. Products having greater areal densities must be processed using more penetrating x-rays. The

  17. Effects of electron beam irradiation on physicochemical properties of corn flour and improvement of the gelatinization inhibition.

    Science.gov (United States)

    Xue, Peiyu; Zhao, Yue; Wen, Chengrong; Cheng, Sheng; Lin, Songyi

    2017-10-15

    The properties and viscosity-reduction mechanism of corn flour irradiated by electron beam have not been understood properly. Here, we investigate the effects of electron beam irradiation (EBI) on the gelatinization and physicochemical properties of corn flour irradiated by 0-5.40kGy of electron beam. The total starch and crude fiber contents of corn flour decreased significantly (P<0.05) after EBI treatment, while the moisture and reducing sugar contents increased significantly (P<0.05). EBI caused perforations on the corn flour particle surfaces, and the irradiated parts of the particles would gradually peel off and afford smooth surfaces, spherical structures, and smaller sizes. Molecular chains of corn flour broke owing to EBI. After irradiation, the pasting peak viscosity decreased dramatically (P<0.01) from 1251.74 to 7.16Pa·s, showing that the gelatinization of corn flour was completely inhibited. Thus, EBI can be used to inhibit the gelatinization of corn flour, which may be beneficial for industrial and food formulations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Space charge effects in intense electron beams related to electron cooling systems

    CERN Document Server

    Korotaev, Yu V; Petrov, A; Sidorin, A; Smirnov, A; Syresin, E M

    2000-01-01

    The review of researches performed by JINR-CERN-ITEP collaboration in 1994-1995 and by JINR group in 1996-1998 years is presented. The research has the goal to study theoretically and experimentally a possibility of electron beam space neutralization and formation of a stable and intense neutralized electron beam (NEB). (4 refs).

  19. Imperative function of electron beams in low-energy plasma focus ...

    Indian Academy of Sciences (India)

    A 2.2 kJ plasma focus device was analysed as an electron beam and an X-ray source that operates with argon gas refilled at a specific pressure. Time-resolved X-ray signals were observed using an array of PIN diode detectors, and the electron beam energy was detected using a scintillator-assisted photomultiplier tube.

  20. Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation

    Directory of Open Access Journals (Sweden)

    Valeriy Shchavlev

    2012-12-01

    Full Text Available Electron beam welding (EBW shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process.

  1. Plasma charge current for controlling and monitoring electron beam welding with beam oscillation.

    Science.gov (United States)

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-12-14

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process.

  2. Modification of PLGA Nanofibrous Mats by Electron Beam Irradiation for Soft Tissue Regeneration

    Directory of Open Access Journals (Sweden)

    Jae Baek Lee

    2015-01-01

    Full Text Available Biodegradable poly(lactide-co-glycolide (PLGA has found widespread use in modern medical practice. However, the degradation rate of PLGA should be adjusted for specific biomedical applications such as tissue engineering, drug delivery, and surgical implantation. This study focused on the effect of electron beam radiation on nanofibrous PLGA mats in terms of physical properties and degradation behavior with cell proliferation. PLGA nanofiber mats were prepared by electrospinning, and electron beam was irradiated at doses of 50, 100, 150, 200, 250, and 300 kGy. PLGA mats showed dimensional integrity after electron beam irradiation without change of fiber diameter. The degradation behavior of a control PLGA nanofiber (0 kGy and electron beam-irradiated PLGA nanofibers was analyzed by measuring the molecular weight, weight loss, change of chemical structure, and fibrous morphology. The molecular weight of the PLGA nanofibers decreased with increasing electron beam radiation dose. The mechanical properties of the PLGA nanofibrous mats were decreased with increasing electron beam irradiation dose. Cell proliferation behavior on all electron beam irradiated PLGA mats was similar to the control PLGA mats. Electron beam irradiation of PLGA nanofibrous mats is a potentially useful approach for modulating the biodegradation rate of tissue-specific nonwoven nanofibrous scaffolds, specifically for soft tissue engineering applications.

  3. Electron beam inspection of 16nm HP node EUV masks

    Science.gov (United States)

    Shimomura, Takeya; Narukawa, Shogo; Abe, Tsukasa; Takikawa, Tadahiko; Hayashi, Naoya; Wang, Fei; Ma, Long; Lin, Chia-Wen; Zhao, Yan; Kuan, Chiyan; Jau, Jack

    2012-11-01

    EUV lithography (EUVL) is the most promising solution for 16nm HP node semiconductor device manufacturing and beyond. The fabrication of defect free EUV mask is one of the most challenging roadblocks to insert EUVL into high volume manufacturing (HVM). To fabricate and assure the defect free EUV masks, electron beam inspection (EBI) tool will be likely the necessary tool since optical mask inspection systems using 193nm and 199nm light are reaching a practical resolution limit around 16nm HP node EUV mask. For production use of EBI, several challenges and potential issues are expected. Firstly, required defect detection sensitivity is quite high. According to ITRS roadmap updated in 2011, the smallest defect size needed to detect is about 18nm for 15nm NAND Flash HP node EUV mask. Secondly, small pixel size is likely required to obtain the high sensitivity. Thus, it might damage Ru capped Mo/Si multilayer due to accumulated high density electron beam bombardments. It also has potential of elevation of nuisance defects and reduction of throughput. These challenges must be solved before inserting EBI system into EUV mask HVM line. In this paper, we share our initial inspection results for 16nm HP node EUV mask (64nm HP absorber pattern on the EUV mask) using an EBI system eXplore® 5400 developed by Hermes Microvision, Inc. (HMI). In particularly, defect detection sensitivity, inspectability and damage to EUV mask were assessed. As conclusions, we found that the EBI system has capability to capture 16nm defects on 64nm absorber pattern EUV mask, satisfying the sensitivity requirement of 15nm NAND Flash HP node EUV mask. Furthermore, we confirmed there is no significant damage to susceptible Ru capped Mo/Si multilayer. We also identified that low throughput and high nuisance defect rate are critical challenges needed to address for the 16nm HP node EUV mask inspection. The high nuisance defect rate could be generated by poor LWR and stitching errors during EB writing

  4. Effects of irradiation as a pretreatment in enzymatic hydrolysis of cellulose materials. [Electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, K.; Miyake, S.; Uda, I. (Sumitomo Electric Industries Ltd., Osaka (Japan))

    1983-01-01

    A flowchart shows the various processes investigated. Using rice straw and chaff as the materials, irradiation was carried out by an electron beam accelerator. After irradiation, some samples were milled and others treated by alkali and then hydrolized by an enzyme. Other samples were simultaneously milled and hydrolyzed by enzyme. The amount of glucose generated by saccharification was measured for each process. Results are shown for (a) effect of irradiation on particle size, (b) effect of irradiation on glucose yield, (c) effect of irradiation dose on lignin extraction by alkali treatment, (d) effects of NaOH concentration and irradiation dose on lignin extraction, (e) effects of temperature and irradiation dose on lignin extraction.

  5. Electron-beam initiated polymerization of acrylate compositions 1 : FTIR monitoring of incremental irradiation

    CERN Document Server

    Patacz, C; Coqueret, X

    2000-01-01

    The electron-beam induced polymerization of some representative formulations including acrylate functional oligomers and diluents has been investigated by means of FTIR spectroscopy applied to films that were cured under a nitrogen flow. In order to gain a deeper insight into the reactivity of the polymerizable systems, the conversion-dose relationship was examined with emphasis on the following points : depth cure profile of the films, and the additivity of effects of incremental radiation doses on monomer conversion. It was shown to be possible to reproduce the actual polymerization profile from discontinuous measurements. This remarkable result is tentatively explained by the geometry of the samples causing limited thermal effects and by the minor influence of possible inhibition and post-polymerization that could influence each of the incremental transformations compared to a single large dose treatment. This method provides a fine tool for revealing differences in kinetic behavior between polymerizable m...

  6. Surgical management of retroperitoneal sarcomas associated with external and intraoperative electron beam radiotherapy.

    Science.gov (United States)

    Bobin, J Y; Al-Lawati, T; Granero, L E; Adham, M; Romestaing, P; Chapet, O; Issac, S; Gerard, J P

    2003-10-01

    To report outcomes of adults with retroperitoneal sarcoma (RS) treated by surgery, external beam radiotherapy (EBRT) and intraoperative electron beam radiotherapy (IORT). From July 1988 to February 2001; 24 patients with primary and recurrent RS were diagnosed and treated. The median dose and energy of IORT delivered was 15 Gy/9meV. EBRT dose varies between 45-50 Gy. There were five primary and 19 recurrent tumours. One primary and five recurrent tumours underwent R0 resection. There were 12 liposarcomas and 19 grade I tumours; 13 patients developed local recurrence and three developed distant metastases.Twenty-two patients received IORT associated with EBRT: 11 developed recurrences. Six patients developed Neurotoxicity (4 grade II and 2 grade III). Disease free survival and overall survival at 5 years was 28 and 56% respectively. EBRT with IORT treatment is a promising technique for local control. Lower recurrence rates are associated with radical (R0) surgical procedures.

  7. Analyses on curing process of electron beam radiation in epoxy resins

    Energy Technology Data Exchange (ETDEWEB)

    Sui Gang; Zhang Zuoguang; Chen Changqi; Zhong Weihong

    2003-02-17

    Epoxy resins have already been applied in electron beam (EB) curable composites structures extensively. The effects of different initiators and diluents on Shell Epon 828 radiation reaction were discussed in the paper, and the same radiation reaction systems were also explored using a heat treatment. The experimental results indicated cationic photoinitiator can initiate EB radiation curing of epoxy resin and traditionally heat-cured systems are not always suitable for the EB curing. The use of diluents would reduce the curing degree of resin and reactive diluents have less effect. The cationic ring-opening polymerization process including the decomposition of diaryliodonium salts under EB radiation at the initial stage and production of protonic acid that can initiate polyreaction was validated in the experiments. The characteristic of cured field and penetration process of EB in Shell Epon 828 system was also studied, and the whole cured area was found to be consisting of many lamellar structures.

  8. An Experimental Evaluation of Electron Beam Welded Thixoformed 7075 Aluminum Alloy Plate Material

    Directory of Open Access Journals (Sweden)

    Ava Azadi Chegeni

    2017-12-01

    Full Text Available Two plates of thixoformed 7075 aluminum alloy were joined using Electron Beam Welding (EBW. A post-welding-heat treatment (PWHT was performed within the semi-solid temperature range of this alloy at three temperatures, 610, 617 and 628 °C, for 3 min. The microstructural evolution and mechanical properties of EB welded plates, as well as the heat-treated specimens, were investigated in the Base Metal (BM, Heat Affected Zone (HAZ, and Fusion Zone (FZ, using optical microscopy, Scanning Electron Microscopy (SEM, EDX (Energy Dispersive X-ray Analysis, and Vickers hardness test. Results indicated that after EBW, the grain size substantially decreased from 67 µm in both BM and HAZ to 7 µm in the FZ, and a hardness increment was observed in the FZ as compared to the BM and HAZ. Furthermore, the PWHT led to grain coarsening throughout the material, along with a further increase in hardness in the FZ.

  9. New algorithm for dynamical friction of ions in a magnetized electron beam

    Science.gov (United States)

    Bruhwiler, David L.; Webb, Stephen D.

    2017-03-01

    Relativistic magnetized electron cooling in untested parameter regimes is essential to achieve the ion luminosity requirements of proposed electron-ion collider designs. Therefore, accurate calculations of magnetized dynamic friction are required, with the ability to include all relevant physics that might increase the cooling time, including space charge forces, field errors and complicated phase space distributions of imperfectly magnetized electron beams. We present a fundamentally new analytic treatment of momentum transfer from a single magnetized electron to a drifting ion, with arbitrary initial conditions and arbitrary interaction time. The map describing such collisions, which is derived from a Hamiltonian and conserves momentum, removes any need to numerically integrate the complicated Larmor trajectories. This important result, made possible by effectively exploiting the perturbative nature of the problem, will enable rapid semi-analytic calculations of dynamic friction on ions in magnetized cooling systems for arbitrary electron distributions.

  10. Remotion of organic compounds of actual industrial effluents by electron beam irradiation

    Science.gov (United States)

    Sampa, M. H. O.; Duarte, C. L.; Rela, P. R.; Somessari, E. S. R.; Silveira, C. G.; Azevedo, A. L.

    1998-06-01

    Organic compounds has been a great problem of environmental pollution, the traditional methods are not effecient on removing these compounds and most of them are deposited to ambient and stay there for long time causing problems to the environment. Ionizing radiation has been used with success to destroy organic molecules. Actual industrial effluents were irradiated using IPEN's electron beam wastewater pilot plant to study organic compounds degradation. The samples were irradiated with and without air mixture by different doses. Irradiation treatment efficiency was evaluated by the Cromatography Gas Analyses of the samples before and after irradiation. The studied organic compounds were: phenol, chloroform, tetrachloroethylene (PCE), carbon tetrachloride, trichloroethylene (TCE), 1,1-dichloroethane, dichloromethane, benzene, toluene and xilene. A degradation superior to 80% was achieved for the majority of the compounds with air addition and 2kGy delivered dose condition. For the samples that were irradiated without air addition the degradation was higher.

  11. Remotion of organic compounds of actual industrial effluents by electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Sampa, M.H.O.; Duarte, C.L.; Rela, P.R.; Somessari, E.S.R.; Silveira, C.G.; Azevedo, A.L

    1998-06-01

    Organic compounds has been a great problem of environmental pollution, the traditional methods are not efficient on removing these compounds and most of them are deposited to ambient and stay there for long time causing problems to the environment. Ionizing radiation has been used with success to destroy organic molecules. Actual industrial effluents were irradiated using IPEN's electron beam wastewater pilot plant to study organic compounds degradation. The samples were irradiated with and without air mixture by different doses. Irradiation treatment efficiency was evaluated by the Cromatography Gas Analyses of the samples before and after irradiation. The studied organic compounds were: phenol, chloroform, tetrachloroethylene (PCE), carbon tetrachloride, trichloroethylene (TCE), 1,1-dichloroethane, dichloromethane, benzene, toluene and xilene. A degradation superior to 80% was achieved for the majority of the compounds with air addition and 2kGy delivered dose condition. For the samples that were irradiated without air addition the degradation was higher.

  12. Generating a Homogeneous Dose Distribution in the Junction Region between Two Adjacent Fields in Electron Beam Therapy

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Tahmasebi Birgani

    2010-09-01

    Full Text Available Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new method for generating a homogeneous dose distribution in the junction region between two adjacent fields in electron beam therapy. Materials and Methods: Several approaches have been proposed to solve the problem of ‘hot’ and ‘cold’ spots in the junction region between abutting electron fields. These techniques are based on beam-edge modifying devices or penumbra generators which act to broaden the electron beam penumbra, and thus facilitate field matching. But use of these devices is time consuming and design of the modifications to the applicators are generally applicator dependent. An idea which was originally proposed for matching two adjacent photon fields (with dose inhomogeneity of about 2% is resurrected here. This method is based on the rotation of the gantry such that the adjacent fields have a common edge and the overlap region in treatment volume is eliminated. For this purpose, the effective source to surface distance (SSDeff for the available electron beam energies (6, 9, 12 and 15 MeV and applicators (cones (6 × 6, 10 × 10, 15 ×15, 20 × 20 and 25 × 25 cm2 have been determined for a Varian 2100C linear accelerator. Result: Using SSDeff, in respect to beam divergence, one can use the photon beam behavior for electron beams and achieve a uniform dose distribution in adjacent electron fields. Discussion and Conclusion: Compared to beam-edge modifying devices or penumbra generators that are usually time consuming to plan and set up, rotating the gantry to eliminate the overlap region is simple and applicable in the problem of abutting

  13. Generation of Double-Decker Femtosecond Electron Beams in a Photoinjector

    CERN Document Server

    Yang Jin Feng; Kondoh, Takafumi; Kozawa, Takahiro; Kuroda, Y; Tagawa, Seiichi; Yoshida, Yoichi

    2005-01-01

    The femtosecond electron beam is a practical source in the pump-probe experiment for studies of ultrafast physical/chemical reactions in materials, in which a mode-locked ultrashort laser light is used as a probe source. The synchronized time jitter between the electron beam and the laser light limits the time resolution in the experiment. In order to reduce the time jitter, a new concept of synchronized double-decker electron beam generation in a photoinjector was proposed. The double electron beams were observed in an S-band photocathode RF gun by injecting two laser beams which produced with a picosecond laser. The double electron beams were compressed into 400fs(rms) with a phase-space rotation technique in magnetic fields. The beams, which one is used as a pump source and another is used as a probe source, are expected for ultrafast reaction studies in femtosecond resolution.

  14. Mechanical and thermal properties of electron beam-irradiated polypropylene reinforced with Kraft lignin

    Science.gov (United States)

    Sugano-Segura, A. T. R.; Tavares, L. B.; Rizzi, J. G. F.; Rosa, D. S.; Salvadori, M. C.; dos Santos, D. J.

    2017-10-01

    Polypropylene reinforced with Kraft lignin composites (0, 2.5, 5.0 and 10.0 wt% lignin) were submitted to electron beam (EB) irradiation at doses of 0, 50, 100 and 250 kGy. Kraft lignin incorporation maintained Young´s modulus values, even at electron beam doses up to 100 kGy (10 wt% lignin). The yield stress losses were also reduced by the addition of lignin to polypropylene. Fourier transform infrared spectroscopy (FTIR) results showed low formation of carboxyl and hydroxyl groups for composites containing lignin. Dynamic mechanical analysis (DMA) curves indicated a synergistic effect between Kraft lignin and electron beam irradiation on the storage modulus (E´). Several properties evolved as a function of the Kraft lignin content. Synergistic effects between Kraft lignin incorporation and electron beam radiation contribute to applications that require the mechanical and thermal properties of iPP to be maintained, even after high doses of electron beam radiation.

  15. Small high-power electron-beam device for manufacturing work and physical experiments in space

    Science.gov (United States)

    Paton, B. E.; Sheliagin, V. D.; Nazarenko, O. K.; Lankin, Iu. N.; Mokhnach, V. K.

    The paper examines the design of a high-power electron-beam device with an autonomous dc-voltage source that was used for electron-beam injection in the Araks experiment and can be used for electron-beam welding in the context of space manufacturing. The design principle is described, and the specifications of the main units of the device are presented, including the units responsible for the conversion of the dc voltage of the primary source to ac voltage, the rectification of the high voltage, and electron-beam injection. Also considered are the units for electron-beam control and for the conversion of the telemetered parameters of the device into analog voltage. A block diagram is presented along with an oscillogram of the beam current and a cyclogram of device operation.

  16. Single pass electron beam cooling of gold ions between EBIS LINAC and booster is theoretically possible!

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, A.

    2011-01-01

    Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Many issues, regarding a low energy high current electron beam that is needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, were examined. Computations and some experimental data indicate that none of these issues is a show stopper. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in about one meter. Hence, this option cooling deserves further more serious considerations.

  17. Low-Energy Plasma Focus Device as an Electron Beam Source

    Directory of Open Access Journals (Sweden)

    Muhammad Zubair Khan

    2014-01-01

    Full Text Available A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line radiations were registered upon usage as targets. The maximum electron beam charge and density were estimated to be 0.31 μC and 13.5×1016/m3, respectively. The average energy of the electron beam was 500 keV. The high flux of the electron beam can be potentially applicable in material sciences.

  18. Low-Energy Plasma Focus Device as an Electron Beam Source

    Science.gov (United States)

    Seong Ling, Yap; Naresh Kumar, Nitturi; Lian Kuang, Lim; Chiow San, Wong

    2014-01-01

    A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line radiations were registered upon usage as targets. The maximum electron beam charge and density were estimated to be 0.31 μC and 13.5 × 1016/m3, respectively. The average energy of the electron beam was 500 keV. The high flux of the electron beam can be potentially applicable in material sciences. PMID:25544952

  19. Effect of weld spacing on microstructure and mechanical properties of CLAM electron beam welding joints

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Yutao; Huang, Bo, E-mail: aufa0007@163.com; Zhang, Junyu; Zhang, Baoren; Liu, Shaojun; Huang, Qunying

    2016-11-15

    Highlights: • The welded joints of CLAM steel with different weld spacings have been fabricated with electron beam welding, and a simplified model of CLAM sheet was proposed. • The microstructure and mechanical properties such as microhardness, impact and tensile were investigated at different welding spacing for both conditions of as-welded and post weld heat treatment (PWHT). • The effect of the welding thermal cycle was significantly when the weld spacings were smaller than 4 mm. • When the weld spacing was small enough, the original microstructures would be fragmented with the high heat input. - Abstract: China low activation martensitic (CLAM) steel has been chosen as the primary structural material in the designs of dual function lithium-lead (DFLL) blanket for fusion reactors, China helium cooled ceramic breeder (HCCB) test blanket module (TBM) for ITER and China fusion engineering test reactor (CFETR) blanket. The cooling components of the blankets are designed with high density cooling channels (HDCCs) to remove the high nuclear thermal effectively. Hence, the welding spacing among the channels are small. In this paper, the welded joints of CLAM steel with different weld spacings have been fabricated with electron beam welding (EBW). The weld spacing was designed to be 2 mm, 3 mm, 4 mm, 6 mm and 8 mm. The microstructure and mechanical properties such as microhardness, impact and tensile were investigated at different welding spacing for both conditions of as-welded and post weld heat treatment (PWHT). The PWHT is tempering at 740 °C for 120 min. The results showed that the grain size in the heat affected zone (HAZ) increased with the increasing weld spacing, and the joint with small weld spacing had a better performance after PWHT. This work would give useful guidance to improve the preparation of the cooling components of blanket.

  20. An Evaluation of Bipolar Junction Transistors as Dosimeter for Megavoltage Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Passos, Renan Garcia de; Vidal da Silva, Rogerio Matias; Silva, Malana Marcelina Almeida; Souza, Divanizia do Nascimento [Departamento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon, sn, Sao Cristovao, SE, 49100-000 (Brazil); Pereira dos Santos, Luiz Antonio [Comissao Nacional de Energia Nuclear, CNEN/CRCN-NE, Av. Prof. Luiz Freire, 1, Recife, PE, 50740-540 (Brazil)

    2015-07-01

    Dosimetry is an extremely important field in medical applications of radiation and nowadays, electron beam is a good option for superficial tumor radiotherapy. Normally, the applied dose to the patient both in diagnostic and therapy must be monitored to prevent injuries and ensure the success of the treatment, therefore, we should always look for improving of the dosimetric methods. Accordingly, the aim of this work is about the use of a bipolar junction transistor (BJT) for electron beam dosimetry. After previous studies, such an electronic device can work as a dosimeter when submitted to ionizing radiation of photon beam. Actually, a typical BJT consists of two PN semiconductor junctions resulting in the NPN structure device, for while, and each semiconductor is named as collector (C), base (B) and emitter (E), respectively. Although the transistor effect, which corresponds to the current amplification, be accurately described by the quantum physics, one can utilize a simple concept from the circuit theory: the base current IB (input signal) is amplified by a factor of β resulting in the collector current IC (output signal) at least one hundred times greater the IB. In fact, the BJT is commonly used as a current amplifier with gain β=I{sub C}/I{sub B}, therefore, it was noticed that this parameter is altered when the device is exposed to ionizing radiation. The current gain alteration can be explained by the trap creation and the positive charges build up, beside the degradation of the lattice structure. Then, variations of the gain of irradiated transistors may justify their use as a dosimeter. Actually, the methodology is based on the measurements of the I{sub C} variations whereas I{sub B} is maintained constant. BC846 BJT type was used for dose monitoring from passive-mode measurements: evaluation of its electrical characteristic before and after irradiation procedure. Thus, IC readings were plotted as a function of the applied dose in 6 MeV electron beam

  1. Suppression of COTR in electron beam imaging diagnosis at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Minjie

    2012-05-15

    The Free-Electron Laser in Hamburg (FLASH) demands electron beams with high peak current to generate high-brilliant, coherent X-ray pulses. Magnetic chicanes are used for longitudinal compression of the electron bunches to achieve the required high peak current. During bunch compression process, microstructures with a modulation length comparable to the visible light can be induced inside the bunch. This leads to coherent emission of optical transition radiation (OTR), which may impede the widely used beam diagnostic based on OTR imaging. In this thesis, two methods of using incoherent scintillation light are proposed to circumvent the problem of coherence effects in beam imaging diagnostics. The method of temporal separation has been proved experimentally to have successfully suppressed coherence effects. The longitudinal beam profiles measured using this method are in good agreement with reference measurements, verifying further the reliability of the method. The method of spatial separation has been investigated in preparation studies, from which an improved experimental setup has been designed.

  2. First results of computerised tomographic angiography using electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, K.J.; Weisser, G.; Neff, K.W.; Mai, S.K.; Denk, S.; Georgi, M. [Inst. fuer Klinische Radiologie, Universitaetsklinikum Mannheim, Heidelberg (Germany)

    1999-05-01

    The aim of this study was to evaluate the suitability of electron beam tomography (EBT) with fast continuous volume scanning for CT angiography (CTA) in chest and abdomen. An Evolution XP EBT scanner with a new software version (12.34) was used. One hundred forty images per study can be acquired in 17 s using 3-mm collimation and overlapping image reconstruction. Study protocols for five different clinical applications of EBT CTA were established and evaluated. The EBT CTA technique was performed in 155 patients. High- and homogeneous density values were achieved along the whole course of the vessels; the mean density in the aorta was > 240 HU. Coeliac axis, superior and inferior mesenteric artery, renal and lumbar arteries were visualised in all cases. Maximum intensity projection and shaded surface display reconstruction demonstrated the relation between aneurysm and aortic branches very well due to an excellent resolution along the z-axis. In large scan volumes overlapping image reconstruction demonstrated better resolution along the z-axis than is available with helical CT. The EBT CTA technique proved to be very well suited excellent suitability for evaluation of pulmonary vessels. Compared with helical CT, EBT CTA offers a shorter scan time, which allows higher contrast enhancement in pulmonary vessels. The identification of intraluminal emboli and mural thrombi has improved. The EBT CTA technique is a very reliable tool for evaluation of aortic disease and pulmonary vessels. (orig.) With 3 figs., 9 refs.

  3. Development of high voltage lead wires using electron beam irradiation

    Science.gov (United States)

    Hun-Jai, Bae; Ho-Soung, Sohn; Dong-Jung, Choi

    1995-09-01

    It is known to those skilled to the art that the electric wires used in high voltage operating electric equipments such as TV sets, microwave ovens, duplicators and etc., have such a structure that a conductor is coated with an insulating layer which is encapsulated with a protecting jacket layer. The electric wire specification such as UL and CSA requires superior cut-through property and flame-retardant property of the wire for utilization safety. The cut-through property of insulation material, for example, high density polyethylene, can be increased by crosslinking of the polymer. Also the flame-retardant property of jacket material which protects the flammable inner insulation can be raised by flame-retardant formulating of the material. In the wire and cable industry, crosslinking by electron beam processing is more effective than that by chemical processing in the viewpoint of through-put rate of the products. The jacket layer of the wire plays the role of protecting the insulation material from burning. The protecting ability of the jacket is related to its inherent flammability and formability of swollen carbonated layer when burned. Crosslinking of the material gives a good formability of swollen carbonated layer, and it protects the insulation material from direct flame. In formulating the flame-retardant jacket material, a crosslinking system must be considered with base polymers and other flame-retardant additives.

  4. Simulation tools for pinched-electron-beam radiographic diodes

    Directory of Open Access Journals (Sweden)

    Stanley Humphries

    2006-02-01

    Full Text Available We describe capabilities of an integrated software suite to simulate pinched-electron-beam diodes for pulsed radiography. In contrast to other reported work using particle-in-cell methods, we employ a ray-tracing code (Trak with advanced capabilities for modeling beam-generated magnetic fields. Ray tracing is a direct approach to a steady-state solution and involves less work than a particle-in-cell calculation. The second software component, GamBet, is a new Monte Carlo code for radiation transport that incorporates effects of the complex electric and magnetic fields at the radiation target. The ray-tracing approach exhibits good convergence in calculations for the diode geometry of the compact radiography (CRAD program at Lawrence Livermore National Laboratory. With a 1.5 MV, 30 ns driver, we predict that the diode can produce a beam with axial length ∼1  mm that generates isotropic bremsstrahlung radiation exceeding 1 rad at 1 m. The ray-tracing procedure encounters convergence problems when applied to the rod-pinch geometry, a configuration used in several pulsed radiographic machines. We observe a fundamental difference in the nature of electron orbits in the two diodes. There is an increased chance for particle-orbit feedback in the rod pinch, so that equilibrium solutions are sensitive to small changes in emission characteristics.

  5. Trends for Electron Beam Accelerator Applications in Industry

    Science.gov (United States)

    Machi, Sueo

    2011-02-01

    Electron beam (EB) accelerators are major pieces of industrial equipment used for many commercial radiation processing applications. The industrial use of EB accelerators has a history of more than 50 years and is still growing in terms of both its economic scale and new applications. Major applications involve the modification of polymeric materials to create value-added products, such as heat-resistant wires, heat-shrinkable sheets, automobile tires, foamed plastics, battery separators and hydrogel wound dressing. The surface curing of coatings and printing inks is a growing application for low energy electron accelerators, resulting in an environmentally friendly and an energy-saving process. Recently there has been the acceptance of the use of EB accelerators in lieu of the radioactive isotope cobalt-60 as a source for sterilizing disposable medical products. Environmental protection by the use of EB accelerators is a new and important field of application. A commercial plant for the cleaning flue gases from a coal-burning power plant is in operation in Poland, employing high power EB accelerators. In Korea, a commercial plant uses EB to clean waste water from a dye factory.

  6. Electron beam lithographic modeling assisted by artificial intelligence technology

    Science.gov (United States)

    Nakayamada, Noriaki; Nishimura, Rieko; Miura, Satoru; Nomura, Haruyuki; Kamikubo, Takashi

    2017-07-01

    We propose a new concept of tuning a point-spread function (a "kernel" function) in the modeling of electron beam lithography using the machine learning scheme. Normally in the work of artificial intelligence, the researchers focus on the output results from a neural network, such as success ratio in image recognition or improved production yield, etc. In this work, we put more focus on the weights connecting the nodes in a convolutional neural network, which are naturally the fractions of a point-spread function, and take out those weighted fractions after learning to be utilized as a tuned kernel. Proof-of-concept of the kernel tuning has been demonstrated using the examples of proximity effect correction with 2-layer network, and charging effect correction with 3-layer network. This type of new tuning method can be beneficial to give researchers more insights to come up with a better model, yet it might be too early to be deployed to production to give better critical dimension (CD) and positional accuracy almost instantly.

  7. Electron Beam Column Developments for Submicron- and Nanolithography

    Science.gov (United States)

    Gesley, Mark; Abboud, Frank; Colby, Dave; Raymond, Frederick; Watson, Sterling

    1993-12-01

    Recent advances in thermal field emission (TFE) electron beam optics column design for lithography are described. Innovations include source vibration mode mapping, accelerating electron gun lens, gun arc-suppression, automated cathode pyrometer, and experimental deflection control system. Several of these column optics and system enhancements, which improve the accuracy and reliability of MEBES\\textregistered IV-TFE systems, have enabled patterning of 64 Mbit dynamic random access memory (DRAM) 5×-reduction reticles. A 13000-hour cathode lifetime has been achieved in a production environment. Automated column setups over the entire operating range with 99% success and 5 min average times are possible. Blanking at 160 MHz with 30 nm (3σ) critical dimension control is achieved. Data obtained with a new experimental deflection control method can quickly compensate stripe butting drift to high accuracy. Challenges in mask patterning for advanced applications are then considered. Several accuracy and throughput issues for advanced 5× reticles for DRAM, 1× masks, and nanolithography are discussed. Examples are given of scaling recent system data as a means of estimating future error budget components.

  8. Hydrogels Synthesized by Electron Beam Irradiation for Heavy Metal Adsorption

    Directory of Open Access Journals (Sweden)

    Elena Manaila

    2017-05-01

    Full Text Available Poly(acrylamide co-acrylic acid hydrogels were prepared by free-radical copolymerization of acrylamide and acrylic acid in aqueous solutions using electron beam irradiation in the dose range of 2.5 kGy to 6 kGy in atmospheric conditions and at room temperature. The influence of the absorbed dose, the amount of cross-linker (trimethylolpropane trimethacrylate and initiator (potassium persulfate on the swelling properties and the diffusion coefficient and network parameters of hydrogels were investigated. The structure and morphology of hydrogels were characterized by Fourier Transform Infrared Spectroscopy (FTIR and Scanning Electron Microscopy (SEM. The use of the obtained hydrogels by the removal of Cu2+ and Cr6+ from aqueous solutions was investigated at room temperature. During the adsorption of metal ions on hydrogels, the residual metal ion concentration in the solution was measured by an atomic absorption spectrophotometer (AAS. It has been established that the use of a relatively small amount of trimethylolpropane trimethacrylate for hydrogel preparation has led to the increasing of swelling up to 8500%.

  9. Simplifying Electron Beam Channeling in Scanning Transmission Electron Microscopy (STEM).

    Science.gov (United States)

    Wu, Ryan J; Mittal, Anudha; Odlyzko, Michael L; Mkhoyan, K Andre

    2017-08-01

    Sub-angstrom scanning transmission electron microscopy (STEM) allows quantitative column-by-column analysis of crystalline specimens via annular dark-field images. The intensity of electrons scattered from a particular location in an atomic column depends on the intensity of the electron probe at that location. Electron beam channeling causes oscillations in the STEM probe intensity during specimen propagation, which leads to differences in the beam intensity incident at different depths. Understanding the parameters that control this complex behavior is critical for interpreting experimental STEM results. In this work, theoretical analysis of the STEM probe intensity reveals that intensity oscillations during specimen propagation are regulated by changes in the beam's angular distribution. Three distinct regimes of channeling behavior are observed: the high-atomic-number (Z) regime, in which atomic scattering leads to significant angular redistribution of the beam; the low-Z regime, in which the probe's initial angular distribution controls intensity oscillations; and the intermediate-Z regime, in which the behavior is mixed. These contrasting regimes are shown to exist for a wide range of probe parameters. These results provide a new understanding of the occurrence and consequences of channeling phenomena and conditions under which their influence is strengthened or weakened by characteristics of the electron probe and sample.

  10. Electron Beam Freeform Fabrication of Titanium Alloy Gradient Structures

    Science.gov (United States)

    Brice, Craig A.; Newman, John A.; Bird, Richard Keith; Shenoy, Ravi N.; Baughman, James M.; Gupta, Vipul K.

    2014-01-01

    Historically, the structural optimization of aerospace components has been done through geometric methods. A monolithic material is chosen based on the best compromise between the competing design limiting criteria. Then the structure is geometrically optimized to give the best overall performance using the single material chosen. Functionally graded materials offer the potential to further improve structural efficiency by allowing the material composition and/or microstructural features to spatially vary within a single structure. Thus, local properties could be tailored to the local design limiting criteria. Additive manufacturing techniques enable the fabrication of such graded materials and structures. This paper presents the results of a graded material study using two titanium alloys processed using electron beam freeform fabrication, an additive manufacturing process. The results show that the two alloys uniformly mix at various ratios and the resultant static tensile properties of the mixed alloys behave according to rule-of-mixtures. Additionally, the crack growth behavior across an abrupt change from one alloy to the other shows no discontinuity and the crack smoothly transitions from one crack growth regime into another.

  11. Influence of Surface Roughness in Electron Beam Welding

    Science.gov (United States)

    Wiednig, C.; Stiefler, F.; Enzinger, N.

    2016-03-01

    The requirements of welded components are rising continuously through increasing demands in engineering. But in engineering not only the quality of welds is important also an economic and timesaving production is crucial. Especially in welding of large cross sections economization potential is existing and significant. Beside the welding technique itself the joint preparation is a major part of work. Electron beam welding has some major advantages in this area. Due the high energy density a very short welding time as well as a small heat affected zone can be achieved. Furthermore the joint preparation can be held simple. Nevertheless, a careful machining and cleaning of the joint surfaces is recommended in literature. In addition to geometric tolerances a specific surface roughness should be kept. These statements are quite general and unspecific. In this contribution a systematic investigation on the influence of joint preparation on the joint properties is presented. By performing several welding experiments with different surface roughness this study provides empirical conclusions. Beside the microscopic investigation of different cross sections and mechanical tests of the welded samples also the process stability during welding was reviewed.

  12. Structural Integrity of an Electron Beam Melted Titanium Alloy

    Directory of Open Access Journals (Sweden)

    Robert Lancaster

    2016-06-01

    Full Text Available Advanced manufacturing encompasses the wide range of processes that consist of “3D printing” of metallic materials. One such method is Electron Beam Melting (EBM, a modern build technology that offers significant potential for lean manufacture and a capability to produce fully dense near-net shaped components. However, the manufacture of intricate geometries will result in variable thermal cycles and thus a transient microstructure throughout, leading to a highly textured structure. As such, successful implementation of these technologies requires a comprehensive assessment of the relationships of the key process variables, geometries, resultant microstructures and mechanical properties. The nature of this process suggests that it is often difficult to produce representative test specimens necessary to achieve a full mechanical property characterisation. Therefore, the use of small scale test techniques may be exploited, specifically the small punch (SP test. The SP test offers a capability for sampling miniaturised test specimens from various discrete locations in a thin-walled component, allowing a full characterisation across a complex geometry. This paper provides support in working towards development and validation strategies in order for advanced manufactured components to be safely implemented into future gas turbine applications. This has been achieved by applying the SP test to a series of Ti-6Al-4V variants that have been manufactured through a variety of processing routes including EBM and investigating the structural integrity of each material and how this controls the mechanical response.

  13. Numerical model of the plasma formation at electron beam welding

    Science.gov (United States)

    Trushnikov, D. N.; Mladenov, G. M.

    2015-01-01

    The model of plasma formation in the keyhole in liquid metal as well as above the electron beam welding zone is described. The model is based on solution of two equations for the density of electrons and the mean electron energy. The mass transfer of heavy plasma particles (neutral atoms, excited atoms, and ions) is taken into account in the analysis by the diffusion equation for a multicomponent mixture. The electrostatic field is calculated using the Poisson equation. Thermionic electron emission is calculated for the keyhole wall. The ionization intensity of the vapors due to beam electrons and high-energy secondary and backscattered electrons is calibrated using the plasma parameters when there is no polarized collector electrode above the welding zone. The calculated data are in good agreement with experimental data. Results for the plasma parameters for excitation of a non-independent discharge are given. It is shown that there is a need to take into account the effect of a strong electric field near the keyhole walls on electron emission (the Schottky effect) in the calculation of the current for a non-independent discharge (hot cathode gas discharge). The calculated electron drift velocities are much bigger than the velocity at which current instabilities arise. This confirms the hypothesis for ion-acoustic instabilities, observed experimentally in previous research.

  14. Pulsed electron beam annealing of As and B implanted silicon

    Energy Technology Data Exchange (ETDEWEB)

    Barbier, D.; Chemisky, G.; Laugier, A. (Institut National des Sciences Appliquees de Lyon 69 - Villeurbanne (France)); Grob, J.J.; Siffert, P.; Stuck, R. (Centre de Recherche Nucleaire, 67 - Strasbourg (France))

    1983-01-01

    p-type (100) silicon wafers have been implanted either by As or B ions at 20 and 200 keV energies and doses of 10/sup 16/cm/sup -2/. Pulsed electron beam annealing has been performed with fluences of 1.1 and 1.4J/cm/sup 2/ using a mean electron energy of 15 keV. The pulse duration was 50 ns. The annealed layers have been investigated by Rutherford backscattering under random and channeling conditions and by S.I.M.S. profiling. Good crystal regrowth and high dopant activation occur in all cases except for the 200 keV Boron implant. Impurities redistribution is observed but no significant segregation effects appear. The experimental profiles are in good agreement with a diffusion model using a modified green function solution and taking into account dopant diffusion in liquid phase and the computed melt front location. The deduced diffusion coefficient are in the 5.10/sup -5/cm/sup 2//s range for boron and 2.10/sup -4/cm/sup 2//s range for arsenic.

  15. Supershort avalanche electron beam in SF_{6} and krypton

    Directory of Open Access Journals (Sweden)

    Cheng Zhang (章程

    2016-03-01

    Full Text Available Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF_{6} in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ∼130  kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ∼1.6  ns. SAEB parameters in SF_{6} are compared with those obtained in krypton (Kr, nitrogen (N_{2}, air, and mixtures of SF_{6} with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF_{6} and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N_{2} and air (ranging from hundreds of milliamps to several amperes. Furthermore, the concentration of SF_{6} additive could significantly reduce the SAEB current in N_{2}-SF_{6} mixture, but it slightly affected the SAEB current in Kr-SF_{6} mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.

  16. Advanced Electron Beam Diagnostics for the FERMI FEL

    CERN Document Server

    Ferianis, M; D'Auria, G; Di Mitri, S

    2005-01-01

    Fermi is the fourth generation light source currently under design at ELETTRA: based on the Harmonic Generation (HG) scheme it will generate FEL radiation in the 100-10nm range. The successful implementation of the HG scheme calls also for precise knowledge of electron beam emittances and energy spread as well as for very accurate control on the photon to electron interaction, in the Undulator sections. In this paper we present our design for two fundamental Diagnostics foreseen for the new FERMI LINAC: the Beam Position Monitors (BPM) and the Transverse Deflecting cavity set-up. Sensitivity studies on transverse beam displacement effects on global stability of FEL output radiation dictate the ultimate performance to be provided by the BPM system. Due to non negligible longitudinal occupancy of a cavity type BPM, some efforts have been put to study compact cavity BPM configuration. A proper set-up of RF deflecting cavity combined with the vertical ramp foreseen at the end of the LINAC provide a powerful tool ...

  17. Electron beam ion sources for student education at universities

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, Erik [DREEBIT GmbH, Dresden (Germany); Zschornack, Guenter [TU Dresden, Dresden (Germany)

    2014-07-01

    Ion beams have become essential tools used in many fields of fundamental research as well as industrial applications. Thus, it is important for todays physics students to understand the basics of ion beam creation, transportation as well as ion-surface interactions. We present results from laboratory training courses using table-top sized electron beam ion sources of the Dresden EBIT type which is able to produce a large spectrum of ions with low or high charge states. The initial ion beam is guided through several ion optical elements like Einzel lenses and deflectors, is separated by the charge-to-mass ratio of its components with a Wien-Filter or dipole analyzing magnet and is detected in a Faraday Cup. A specific assembly for laboratory training as used at the Technische Universitaet Dresden and the Jagiellonian University in Krakow, Poland, is introduced. In typical experiments, students analyze the charge-to-mass ratio spectrum from a Dresden EBIT measured using a Wien Filter. The composition of the extracted ion beam can be manipulated by the gas pressure or the ionisation time. In a wider context, the atomic physics processes occurring especially during the production of highly charged ions also appear in nuclear fusion facilities as well as in many astrophysical phenomena, for example supernovas. Such aspects can be discussed in order to help students connect to modern research carried out at large international facilities.

  18. The electron beam diagnostic of the clustered supersonic nitrogen jets

    Science.gov (United States)

    Avtaeva, S. V.; Yakovleva, T. S.; Kalyada, V. V.; Zarvin, A. E.

    2017-11-01

    Axial and radial distributions of the rotational temperature and density of N2 molecules in supersonic nitrogen jets formed with conic nozzles (critical diameters dcr of 0.17 and 0.21 mm) were studied using the electron beam fluorescence technique at stagnation pressures P0 of 0.1-0.6 MPa. A rotational temperature Tr , equaling a gas temperature Tg owing to fast RT relaxation, was obtained using the rotational line relative intensity distribution in (0-1) vibrational band of the N2 first negative system. Gas density profiles in the jets were obtained using the integral intensity of the band. It is found, Tr at the nozzle outlet is of the order of a few tens of Kelvin and at further expansion Tr drops up to 15-20K at distance of (100-200) dcr . The gas temperature and density distributions in the studied supersonic nitrogen jets are not similar to the isentropic distributions. It is shown that the lower is the stagnation pressure the faster the gas density and temperature decrease with distance from the nozzle. Increase in P0 leads to elevating Tg in the jets. A reason for this effect may be cluster formation in the jets. Estimations of cluster mean sizes in the jets using Hagena’s parameter show presence of large clusters (M≥200) at P0 = 0.4-0.6 MPa.

  19. Supershort avalanche electron beam in SF6 and krypton

    Science.gov (United States)

    Zhang, Cheng; Tarasenko, Victor F.; Gu, Jianwei; Baksht, Evgeni Kh.; Beloplotov, Dmitry V.; Burachenko, Alexander G.; Yan, Ping; Lomaev, Mikhail I.; Shao, Tao

    2016-03-01

    Runaway electrons play an important role in the avalanche formation in nanosecond- and subnanosecond- pulse discharges. In this paper, characteristics of a supershort avalanche electron beam (SAEB) generated at the subnanosecond and nanosecond breakdown in sulfur hexafluoride (SF6 ) in an inhomogeneous electric field were studied. One pulser operated at negative polarity with voltage pulse amplitude of ˜130 kV and rise time of 0.3 ns. The other pulser operated at negative polarity with voltage pulse amplitude of 70 kV and rise time of ˜1.6 ns . SAEB parameters in SF6 are compared with those obtained in krypton (Kr), nitrogen (N2 ), air, and mixtures of SF6 with krypton or nitrogen. Experimental results showed that SAEB currents appeared during the rise-time of the voltage pulse for both pulsers. Moreover, amplitudes of the SAEB current in SF6 and Kr approximately ranged from several to tens of milliamps at atmospheric pressure, which were smaller than those in N2 and air (ranging from hundreds of milliamps to several amperes). Furthermore, the concentration of SF6 additive could significantly reduce the SAEB current in N2-SF6 mixture, but it slightly affected the SAEB current in Kr -SF6 mixture because of the atomic/molecular ionization cross section of the gas had a much greater impact on the SAEB current rather than the electronegativity.

  20. SU-E-T-279: A Novel Electron-Beam Combined with Magnetic Field Application for Radiotherapy.

    Science.gov (United States)

    Alezra, D; Nardi, E; Koren, S; Bragilovski, D; Orion, I

    2012-06-01

    The new beam and delivery system consists of an electron accelerator and a system of magnets (one or more). Introducing a transverse magnetic field in and near the tumor, causes the electrons to spiral in this region, thereby producing an effective peak in the depth dose distribution, within the tumor volume. Although the basic idea is not new, we suggest here for the first time, a viable as well as a workable, magnetic field configuration, which in addition to focusing the beam does not interfere with its propagation to the target. The electron accelerator: can be a linear accelerator or any other type electron accelerator, capable of producing different electron energies for different depths and dose absorption accumulation. The Field size can be as small as a pencil beam and as big as any of the other standard field sizes that are used in radiotherapy. The scatter filter can be used or removed. The dose rate accumulation can be as higher as possible.The magnets are able to produce magnetic fields. The order, direction, width, place, shape and number of the magnetic fields define the shape and the Percentage Depth Dose (PDD) curve of the electron beam. Prototypes were successfully tested by means of computer simulation, using:COMSOL-Multiphsics for magnetic fields calculations. FLUKA package, for electron beam MC simulation. Our results suggest that by using an electron beam at different energies, combined with magnetic fields, we could modify the delivered dose. This is caused by manipulating the electron motion via the Lorentz force. The applied magnetic field, will focus the electron beam at a given depth and deposit the energy in a given volume and depth, where otherwise the electron energy will have spread deeper. The direction and magnitude of the magnetic fields will prevent the scattering of the electron beam and its absorption in remote volumes. In practice, we get a pseudo Bragg peak depth dose distribution, applying a relatively low cost system. The

  1. Finite Element Models for Electron Beam Freeform Fabrication Process

    Science.gov (United States)

    Chandra, Umesh

    2012-01-01

    Electron beam freeform fabrication (EBF3) is a member of an emerging class of direct manufacturing processes known as solid freeform fabrication (SFF); another member of the class is the laser deposition process. Successful application of the EBF3 process requires precise control of a number of process parameters such as the EB power, speed, and metal feed rate in order to ensure thermal management; good fusion between the substrate and the first layer and between successive layers; minimize part distortion and residual stresses; and control the microstructure of the finished product. This is the only effort thus far that has addressed computer simulation of the EBF3 process. The models developed in this effort can assist in reducing the number of trials in the laboratory or on the shop floor while making high-quality parts. With some modifications, their use can be further extended to the simulation of laser, TIG (tungsten inert gas), and other deposition processes. A solid mechanics-based finite element code, ABAQUS, was chosen as the primary engine in developing these models whereas a computational fluid dynamics (CFD) code, Fluent, was used in a support role. Several innovative concepts were developed, some of which are highlighted below. These concepts were implemented in a number of new computer models either in the form of stand-alone programs or as user subroutines for ABAQUS and Fluent codes. A database of thermo-physical, mechanical, fluid, and metallurgical properties of stainless steel 304 was developed. Computing models for Gaussian and raster modes of the electron beam heat input were developed. Also, new schemes were devised to account for the heat sink effect during the deposition process. These innovations, and others, lead to improved models for thermal management and prediction of transient/residual stresses and distortions. Two approaches for the prediction of microstructure were pursued. The first was an empirical approach involving the

  2. Characteristic study of electron beam stabilization for deep-UV photoresists

    Science.gov (United States)

    Kim, Myoung-Soo; Choi, Jae-Hak; Rho, Chi H.; Hong, Min-Jong; Jun, Bum-Jin; Gil, Myung-Goon; Kim, Bong-Ho; Ahn, Dong-Jun; Ross, Matthew F.; Wong, Selmer S.

    2000-06-01

    As the design rule of device shrinks below 0.14 micrometer, the higher resolution is required for real device application. With smaller feature size below 0.14 micrometer, the lower coating thickness of resist is essential because of the pattern collapse issue at the high aspect ratio. However, the lower resist thickness induces the problem of etch selectivity due to the limited etch resistance of resist. In this study, the method of electron beam stabilization has been applied for improving the etch selectivity of resist patterns having an aspect ratio less than 3:1. With applying the electron beam stabilization, the Deep-UV photoresists based on the chemical structures of Acetal (AS106) and Escap (UV82) types have been evaluated in the respect of etch selectivity as the functions of an electron beam dose and etch condition. The metal etch rate reductions of 20 percent and 26 percent have been occurred for the resists of Acetal and Escap type, respectively, at 2000 (mu) C/cm2. And the thermal and chemical properties were characterized before and after electron beam stabilization using DSC, TGA, and FT-IR. The cross-sectional views of resist pattern after electron beam processing were also investigated to know the chemical stability of resist during the electron beam process. Based on the experimental results, the application possibility of electron beam stabilization for real device fabrication below 0.14 micrometer has been presented in this paper.

  3. Effects of beam quality in a free-electron laser oscillator with two electron beams

    Science.gov (United States)

    Nam, Soon-Kwon

    2017-11-01

    We have studied the electron beam quality in a free-electron laser (FEL) oscillator by using two electron beams of different harmonically related energies in the FEL facility, which is operated in the infrared and far-infrared regions. The electron beam quality, such as emittance, energy spread, and higher-order modes were studied using an extended three-dimensional (3D) FEL code for two electron beams that we have developed. The variations in the radiation amplitude of the electron beam's emittances, and energy spread were also calculated for a tapered wiggler for the multiparticle and multi-pass number using a new 3D code. The evolution of the radiation field intensity for higher-order modes of the wiggler with beam emittance and energy spread was studied for the two-electron beam's FEL performance. We found that the radiation intensity was degraded due to the energy spread and the emittance of the electron beam. We minimized the degradation of the radiation intensity by optimizing the tapered wiggler for the coupled two-beam FEL oscillator.

  4. Surrogates for validation of electron beam irradiation of foods.

    Science.gov (United States)

    Rodriguez, Oscar; Castell-Perez, M Elena; Ekpanyaskun, Nont; Moreira, Rosana G; Castillo, Alejandro

    2006-07-15

    The aim of this study was to identify a potential surrogate to describe the radiation sensitivity of the most common pathogens encountered in fruits. Three pathogens: Escherichia coli O157:H7 933, Listeria monocytogenes ATCC 51414, and Salmonella Poona, and five non-pathogens: E. coli K-12 MG1655, Listeria innocua Seeliger 1983 (NRRL B-33003 and NRRl B-33014), Enterobacter aerogenes, and Salmonella LT2 were inoculated (populations of 10(7)-10(9) CFU/ml) into model food systems (10% w/w gelatin) and exposed to doses up to 1.0 kGy using a 2 MeV Van der Graaf linear accelerator. The non-pathogen E. coli K-12 MG1655 was highly resistant to radiation (D(10)=0.88 kGy) in comparison to the other strains while L. monocytogenes was the more radiation-resistant pathogen (D(10)=1.09 kGy). Thus, E. coli K-12 MG1655 could be a suitable surrogate for e-beam studies with L. monocytogenes as the indicator pathogen. L. innocua strains were more radiation-sensitive (D(10)=0.66, 0.72 kGy) than their pathogenic counterpart. S. Poona and E. coli O157:H7 were even more radiation-sensitive (D(10)=0.38, 0.36 kGy, respectively). S. LT2 was the least radiation-resistant pathogen with D(10)=0.12 kGy. In a later study, the radiation resistance of the pathogens and the surrogate was evaluated when inoculated in a real food (i.e., fresh cantaloupe). The D(10) values obtained in this experiment were higher than those obtained with the model foods. However, the surrogate was still more radiation-resistant and could therefore be used to indicate decontamination of the target pathogens under electron beam irradiation.

  5. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; ET AL.

    2005-02-28

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linac. The highly successful development of an EBIS at BNL now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based pre-injectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The new RFQ and Linac that are used to accelerate beams from the EBIS to an energy sufficient for injection into the Booster are both very similar to existing devices already in operation at other facilities. Injection into the Booster will occur at the same location as the existing injection from the Tandem.

  6. The Brookhaven National Laboratory electron beam ion source for RHIC.

    Science.gov (United States)

    Alessi, J G; Barton, D; Beebe, E; Bellavia, S; Gould, O; Kponou, A; Lambiase, R; Lockey, R; McNerney, A; Mapes, M; Marneris, Y; Okamura, M; Phillips, D; Pikin, A I; Raparia, D; Ritter, J; Snydstrup, L; Theisen, C; Wilinski, M

    2010-02-01

    As part of a new heavy ion preinjector that will supply beams for the Relativistic Heavy Ion Collider and the National Aeronautics and Space Administration Space Radiation Laboratory, construction of a new electron beam ion source (EBIS) is now being completed. This source, based on the successful prototype Brookhaven National Laboratory Test EBIS, is designed to produce milliampere level currents of all ion species, with q/m=(1/6)-(1/2). Among the major components of this source are a 5 T, 2-m-long, 204 mm diameter warm bore superconducting solenoid, an electron gun designed to operate at a nominal current of 10 A, and an electron collector designed to dissipate approximately 300 kW of peak power. Careful attention has been paid to the design of the vacuum system, since a pressure of 10(-10) Torr is required in the trap region. The source includes several differential pumping stages, the trap can be baked to 400 C, and there are non-evaporable getter strips in the trap region. Power supplies include a 15 A, 15 kV electron collector power supply, and fast switchable power supplies for most of the 16 electrodes used for varying the trap potential distribution for ion injection, confinement, and extraction. The EBIS source and all EBIS power supplies sit on an isolated platform, which is pulsed up to a maximum of 100 kV during ion extraction. The EBIS is now fully assembled, and operation will be beginning following final vacuum and power supply tests. Details of the EBIS components are presented.

  7. Electron beam diagnostic for profiling high power beams

    Science.gov (United States)

    Elmer, John W [Danville, CA; Palmer, Todd A [Livermore, CA; Teruya, Alan T [Livermore, CA

    2008-03-25

    A system for characterizing high power electron beams at power levels of 10 kW and above is described. This system is comprised of a slit disk assembly having a multitude of radial slits, a conducting disk with the same number of radial slits located below the slit disk assembly, a Faraday cup assembly located below the conducting disk, and a start-stop target located proximate the slit disk assembly. In order to keep the system from over-heating during use, a heat sink is placed in close proximity to the components discussed above, and an active cooling system, using water, for example, can be integrated into the heat sink. During use, the high power beam is initially directed onto a start-stop target and after reaching its full power is translated around the slit disk assembly, wherein the beam enters the radial slits and the conducting disk radial slits and is detected at the Faraday cup assembly. A trigger probe assembly can also be integrated into the system in order to aid in the determination of the proper orientation of the beam during reconstruction. After passing over each of the slits, the beam is then rapidly translated back to the start-stop target to minimize the amount of time that the high power beam comes in contact with the slit disk assembly. The data obtained by the system is then transferred into a computer system, where a computer tomography algorithm is used to reconstruct the power density distribution of the beam.

  8. High energy density plasma science with an ultrarelativistic electron beam

    Science.gov (United States)

    Joshi, C.; Blue, B.; Clayton, C. E.; Dodd, E.; Huang, C.; Marsh, K. A.; Mori, W. B.; Wang, S.; Hogan, M. J.; O'Connell, C.; Siemann, R.; Watz, D.; Muggli, P.; Katsouleas, T.; Lee, S.

    2002-05-01

    An intense, high-energy electron or positron beam can have focused intensities rivaling those of today's most powerful laser beams. For example, the 5 ps (full-width, half-maximum), 50 GeV beam at the Stanford Linear Accelerator Center (SLAC) at 1 kA and focused to a 3 micron rms spot size gives intensities of >1020 W/cm-2 at a repetition rate of >10 Hz. Unlike a ps or fs laser pulse which interacts with the surface of a solid target, the particle beam can readily tunnel through tens of cm of steel. However, the same particle beam can be manipulated quite effectively by a plasma that is a million times less dense than air! This is because of the incredibly strong collective fields induced in the plasma by the Coulomb force of the beam. The collective fields in turn react back onto the beam leading to many clearly observable phenomena. The beam paraticles can be: (1) Deflected leading to focusing, defocusing, or even steering of the beam; (2) undulated causing the emission of spontaneous betatron x-ray radiation and; (3) accelerated or decelerated by the plasma fields. Using the 28.5 GeV electron beam from the SLAC linac a series of experiments have been carried out that demonstrate clearly many of the above mentioned effects. The results can be compared with theoretical predictions and with two-dimensional and three-dimensional, one-to-one, particle-in-cell code simulations. These phenomena may have practical applications in future technologies including optical elements in particle beam lines, synchrotron light sources, and ultrahigh gradient accelerators.

  9. Automatic joint tracking for CNC-programmed electron beam welding

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, M.J.; Powers, D.E.

    1985-08-01

    In an effort to provide a means for actively maintaining precise alignment during an entire welding procedure, various types of contact and non-contact joint sensing and tracking methods have been investigated over the years. A stylus riding in the groove or a cam follower running along a machined reference surface that parallels the groove, coupled to a transducer for producing a signal indicative of seam path runout, is one method that has been investigated. Another is the employment of light-sensitive devices, used in both a comparative and a discerning fashion to produce a signal indicative of beam-to-joint alignment. Also, electronic detectors that monitor the magnitude of either electron or x-ray emission coming back from a workpiece and produce a signal indicative of beam-to-joint alignment deviations have been investigated. Of the various methods tried, the one which has proved to be ideal for use in joint sensing and tracking during EB welding is that of monitoring the ''secondary'' electron backflow that results when a workpiece is bombarded with a beam of ''primary'' electrons. This is because the primary electron beam producing this secondary electron backflow is the welding beam itself. Since the welding beam becomes the means for measuring joint location, the technique of sensing secondary electron backflow automatically provides a direct correlation between the actual welding beam position and the joint location measured. Thus, any need for calibrating an auxiliary joint location device to actual welding beam position is eliminated. In addition, this method is least affected by the high amount of vapor and spatter generated during welding. In this article, a system employing Secondary Electron Emission Sensing (SEES) to provide an on-line (''realtime''), truly automatic joint tracking capability will be discussed.

  10. Influence of the electrode gap separation on the pseudospark-sourced electron beam generation

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, J., E-mail: junping.zhao@qq.com [High Voltage Division, School of Electrical Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); State Key Laboratory of Electrical Insulation and Power Equipment, West Xianning Road, Xi' an 710049 (China); Department of Physics, SUPA, University of Strathclyde, Glasgow, G4 0NG Scotland (United Kingdom); Yin, H.; Zhang, L.; Shu, G.; He, W.; Phelps, A. D. R.; Cross, A. W. [Department of Physics, SUPA, University of Strathclyde, Glasgow, G4 0NG Scotland (United Kingdom); Zhang, J.; Zhang, Q. [High Voltage Division, School of Electrical Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); State Key Laboratory of Electrical Insulation and Power Equipment, West Xianning Road, Xi' an 710049 (China)

    2016-07-15

    Pseudospark-sourced electron beam is a self-focused intense electron beam which can propagate without any external focusing magnetic field. This electron beam can drive a beam-wave interaction directly or after being post-accelerated. It is especially suitable for terahertz radiation generation due to the ability of a pseudospark discharge to produce small size in the micron range and very high current density and bright electron beams. In this paper, a single-gap pseudospark discharge chamber has been built and tested with several electrode gap separations to explore the dependence of the pseudospark-sourced electron beam current on the discharge voltage and the electrode gap separation. Experimental results show that the beam pulses have similar pulse width and delay time from the distinct drop of the applied voltage for smaller electrode gap separations but longer delay time for the largest gap separation used in the experiment. It has been found that the electron beam only starts to occur when the charging voltage is above a certain value, which is defined as the starting voltage of the electron beam. The starting voltage is different for different electrode gap separations and decreases with increasing electrode gap separation in our pseudospark discharge configuration. The electron beam current increases with the increasing discharge voltage following two tendencies. Under the same discharge voltage, the configuration with the larger electrode gap separation will generate higher electron beam current. When the discharge voltage is higher than 10 kV, the beam current generated at the electrode gap separation of 17.0 mm, is much higher than that generated at smaller gap separations. The ionization of the neutral gas in the main gap is inferred to contribute more to the current increase with increasing electrode gap separation.

  11. Bending of metal-filled carbon nanotube under electron beam irradiation

    Directory of Open Access Journals (Sweden)

    Abha Misra

    2012-03-01

    Full Text Available Electron beam irradiation induced, bending of Iron filled, multiwalled carbon nanotubes is reported. Bending of both the carbon nanotube and the Iron contained within the core was achieved using two approaches with the aid of a high resolution electron microscope (HRTEM. In the first approach, bending of the nanotube structure results in response to the irradiation of a pristine kink defect site, while in the second approach, disordered sites induce bending by focusing the electron beam on the graphite walls. The HRTEM based in situ observations demonstrate the potential for using electron beam irradiation to investigate and manipulate the physical properties of confined nanoscale structures.

  12. Simulation of Hollow Electron Beam Collimation in the Fermilab Tevatron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Morozov, I.A.; Stancari, G.; Valishev, A.; /Fermilab; Shatilov, D.N.; /Novosibirsk, IYF

    2012-05-01

    The concept of augmenting the conventional collimation system of high-energy storage rings with a hollow electron beam was successfully demonstrated in experiments at the Tevatron. A reliable numerical model is required for understanding particle dynamics in the presence of a hollow beam collimator. Several models were developed to describe imperfections of the electron beam profile and alignment. The features of the imperfections are estimated from electron beam profile measurements. Numerical simulations of halo removal rates are compared with experimental data taken at the Tevatron.

  13. Pharmacological properties of granulocytic colony-stimulating factor pegylated using electron beam synthesis nanotechnologies.

    Science.gov (United States)

    Dygai, A M; Zyuz'kov, G N; Zhdanov, V V; Madonov, P G; Udut, E V; Miroshnichenko, L A; Khrichkova, T Yu; Simanina, E V; Stavrova, L A; Artamonov, A V; Bekarev, A A; Kinsht, D N; Chaikovskiy, A V; Markova, T S; Gurto, R V

    2011-11-01

    Granulocytic CSF pegylated using electron-beam synthesis nanotechnology exhibits pronounced granulomonocytopoiesis-stimulating and SC-mobilizing activity. More potent stimulation of committed precursors against the background of less pronounced activation of polypotent hemopoietic cells is a peculiarity of hemostimulating action of pegylated using electron-beam synthesis nanotechnology granulocytic CSF in comparison with its non-modified analog. The mobilizing effect of pegylated using electron-beam synthesis nanotechnology granulocytic CSF on early progenitor elements surpasses that of non-conjugated cytokine.

  14. Generation of electron beams from a laser-based advanced accelerator at Shanghai Jiao Tong University

    CERN Document Server

    Elsied, Ahmed M M; Li, Song; Mirzaie, Mohammad; Sokollik, Thomas; Zhang, Jie

    2014-01-01

    At Shanghai Jiao Tong University, we have established a research laboratory for advanced acceleration research based on high-power lasers and plasma technologies. In a primary experiment based on the laser wakefield acceleration (LWFA) scheme, multi-hundred MeV electron beams having a reasonable quality are generated using 20-40 TW, 30 femtosecond laser pulses interacting independently with helium, neon, nitrogen and argon gas jet targets. The laser-plasma interaction conditions are optimized for stabilizing the electron beam generation from each type of gas. The electron beam pointing angle stability and divergence angle as well as the energy spectra from each gas jet are measured and compared.

  15. Lateral resolution in focused electron beam-induced deposition: scaling laws for pulsed and static exposure

    Energy Technology Data Exchange (ETDEWEB)

    Szkudlarek, Aleksandra [Empa, Laboratory for Mechanics of Materials and Nanostructures, Thun (Switzerland); AGH University of Science and Technology, Department of Solid State Physics, Faculty of Physics and Applied Computer Science, Krakow (Poland); Szmyt, Wojciech; Kapusta, Czeslaw [AGH University of Science and Technology, Department of Solid State Physics, Faculty of Physics and Applied Computer Science, Krakow (Poland); Utke, Ivo [Empa, Laboratory for Mechanics of Materials and Nanostructures, Thun (Switzerland)

    2014-12-15

    In this work, we review the single-adsorbate time-dependent continuum model for focused electron beam-induced deposition (FEBID). The differential equation for the adsorption rate will be expressed by dimensionless parameters describing the contributions of adsorption, desorption, dissociation, and the surface diffusion of the precursor adsorbates. The contributions are individually presented in order to elucidate their influence during variations in the electron beam exposure time. The findings are condensed into three new scaling laws for pulsed exposure FEBID (or FEB-induced etching) relating the lateral resolution of deposits or etch pits to surface diffusion and electron beam exposure dwell time for a given adsorbate depletion state. (orig.)

  16. Laser-Compton scattering from a 20 MeV electron beam

    CERN Document Server

    Chouffani, K; Harmon, F; Jones, J; Lancaster, G

    2002-01-01

    Laser-Compton scattering (LCS) experiments were carried out at the Idaho Accelerator Center. A 20 MeV electron beam was brought to a head-on collision with a 100 MW 7 ns Nd:YAG laser. We observed clear narrow LCS X-ray spectral peaks resulting from the interaction of the electron beam with the two Nd:YAG laser photon lines of 1064 and 532 nm. The LCS X-ray energy lines and widths were measured as a function of the electron beam energy and energy spread, respectively. The results recorded showed good agreement with the predicted values.

  17. The effect of atoms excited by electron beam on metal evaporation

    CERN Document Server

    Xie Guo Feng; Ying Chun Tong

    2002-01-01

    In atomic vapor laser isotope separation (AVLIS), the metal is heated to melt by electron beams. The vapor atoms may be excited by electrons when flying through the electron beam. The excited atoms may be deexcited by inelastic collision during expansion. The electronic energy transfers translational energy. In order to analyse the effect of reaction between atoms and electron beams on vapor physical parameters, such as density, velocity and temperature, direct-simulation Monte Carlo method (DSMC) is used to simulate the 2-D gadolinium evaporation from long and narrow crucible. The simulation results show that the velocity and temperature of vapor increase, and the density decreases

  18. Generation of Homogeneous and Patterned Electron Beams using a Microlens Array Laser-Shaping Technique

    Energy Technology Data Exchange (ETDEWEB)

    Halavanau, Aliaksei [NICADD, DeKalb; Edstrom, Dean [Fermilab; Gai, Wei [Argonne, HEP; Ha, Gwanghui [Argonne, HEP; Piot, Philippe [NICADD, DeKalb; Power, John [Argonne, HEP; Qiang, Gao [Unlisted, CN; Ruan, Jinhao [Fermilab; Santucci, James [Fermilab; Wisniewski, Eric [Argonne, HEP

    2016-06-01

    In photocathodes the achievable electron-beam parameters are controlled by the laser used to trigger the photoemission process. Non-ideal laser distribution hampers the final beam quality. Laser inhomogeneities, for instance, can be "amplified" by space-charge force and result in fragmented electron beams. To overcome this limitation laser shaping methods are routinely employed. In the present paper we demonstrate the use of simple microlens arrays to dramatically improve the transverse uniformity. We also show that this arrangement can be used to produce transversely-patterned electron beams. Our experiments are carried out at the Argonne Wakefield Accelerator facility.

  19. Contribution to electrical discharge electron beam system for flue gas cleaning method

    Science.gov (United States)

    Cramariuc, R.; Marin, Gh; Martin, D.; Cramariuc, B.; Teodorescu, I.; Munteanu, V.; Ghiuta, V.

    2000-03-01

    Many authors have investigated simultaneous reduction of SO 2 and NO x from flue gas stack emission by electron beam-induced plasma process. Because of high costs, this technology has been applied in only a few countries (Japan, China and Poland) until now. Small countries, consumers of cheap combustibles, produce a great deal of atmospheric pollutants SO 2 and NO x, For this reason there is a great interest in the implementation of cheaper technologies with a similar impact as electron beam processing. This paper presents a series of experimental data for SO 2 and NO x removal by electron beams, electric discharge and ozone in different processing variants of flue gas.

  20. Strengthening effect of nano-scaled precipitates in Ta alloying layer induced by high current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Guangze; Luo, Dian; Fan, Guohua [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Ma, Xinxin, E-mail: maxin@hit.edu.cn [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Wang, Liqin [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2017-05-01

    Highlights: • Ta alloying layer are fabricated by magnetron sputtering and high current pulsed electron beam. • Nano-scaled TaC precipitates forms within the δ-Fe grain after tempering treatment. • The mean diameter of TaC particles is about 5–8 nm. • The hardness of alloying layer increased by over 50% after formation of nano-scaled TaC particle. - Abstract: In this study, the combination of magnetron sputtering and high current pulsed electron beam are used for surface alloying treatment of Ta film on high speed steel. And the Ta alloying layer is about 6 μm. After tempering treatment, TaC phase forms in Ta alloying layer when the treated temperature is over 823 K. Through the TEM and HRTEM observation, a large amount of nano-scaled precipitates (mean diameter 5–8 nm) form within the δ-Fe grain in Ta alloying layer after tempering treatment and these nano-scaled precipitates are confirmed as TaC particles, which contribute to the strengthening effect of the surface alloying layer. The hardness of tempered alloying layer can reach to 18.1 GPa when the treated temperature is 823 K which increase by 50% comparing with the untreated steel sample before surface alloying treatment.

  1. Electron beam characterization of a combined diode rf electron gun

    Directory of Open Access Journals (Sweden)

    R. Ganter

    2010-09-01

    Full Text Available Experimental and simulation results of an electron gun test facility, based on pulsed diode acceleration followed by a two-cell rf cavity at 1.5 GHz, are presented here. The main features of this diode-rf combination are: a high peak gradient in the diode (up to 100  MV/m obtained without breakdown conditioning, a cathode shape providing an electrostatic focusing, and an in-vacuum pulsed solenoid to focus the electron beam between the diode and the rf cavity. Although the test stand was initially developed for testing field emitter arrays cathodes, it became also interesting to explore the limits of this electron gun with metallic photocathodes illuminated by laser pulses. The ultimate goal of this test facility is to fulfill the requirements of the SwissFEL project of Paul Scherrer Institute [B. D. Patterson et al., New J. Phys. 12, 035012 (2010NJOPFM1367-263010.1088/1367-2630/12/3/035012]; a projected normalized emittance below 0.4  μm for a charge of 200 pC and a bunch length of less than 10 ps (rms. A normalized projected emittance of 0.23  μm with 13 pC has been measured at 5 MeV using a Gaussian laser longitudinal intensity distribution on the photocathode. Good agreements with simulations have been obtained for different electron bunch charge and diode geometries. Emittance measurements at a bunch charge below 1 pC were performed for different laser spot sizes in agreement with intrinsic emittance theory [e.g. 0.54  μm/mm of laser spot size (rms for Cu at 274 nm]. Finally, a projected emittance of 1.25+/-0.2  μm was measured with 200 pC and 100  MV/m diode gradient.

  2. Hypernuclear spectroscopy with electron beam at JLab Hall C

    Energy Technology Data Exchange (ETDEWEB)

    Yuu Fujii

    2010-12-01

    Hypernuclear spectroscopy with electron beam at JLab Hall C has been studied since 2000. The first experiment, JLab E89-009, used Short Orbit Spectrometer (SOS) as a kaon arm and a split-pole type spectrometer (ENGE) as an electron arm. E89-009 employed zero-degree tagging method, which tags scattered electrons at zero-degree and the kaon arm also covered zero-degree. This method obtains maximum yield of hypernuclei but sufferers from high rate background of electrons from bremsstrahlung and positrons from pair-creation. Nevertheless, this experiment demonstrated the possibility of the (e,e' K{sup +}) reaction for hypernuclear spectroscopy by obtaining a hypernuclear mass spectrum with an energy resolution of better than 1 MeV (FWHM) [1][2]. However, poor signal to noise ratio and poor statistics requires us to improve the experimental setup. Therefore, E01-011 experiment was proposed based on the success of the JLab E01-011 experiment. Improvements of E01-011 from E09-009 can be summarized as: 1. Employed newly constructed high resolution kaon spectrometer (HKS) as a kaon arm. 2. Employed so-called 'tilt-method' for the electron arm. With the newly constructed HKS, having 2-10-4 momentum resolution, we expect an energy resolution of 400 keV (FWHM). The 'tilt-method' means the electron arm is tilted vertically to the splitter dispersive plane to avoid background electrons from bremsstrahlung and moeller scattering. The setup allowed us to use up to a few tens beam. The experiment was performed in 2005 and final result will be shown shortly. The third experiment, JLab E05-115 experiment was proposed as a natural extension of E01-011 experiment and will be performed in 2009. Improvements of experimental setup are, 1. Employed newly constructed high resolution electron spectrometer (HES) as a electron arm, 2. Employed a new charge-separation magnet (Splitter), fully customized for hypernuclear experiment at Hall C. With the third generation

  3. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; GRANDINETTI, R.; HSEUH, H.; JAVIDFAR, A.; KPONOU, A.; LAMBIASE, R.; LESSARD, E.; LOCKEY, R.; LODESTRO, V.; MAPES, M.; MIRABELLA, D.; NEHRING, T.; OERTER, B.; PENDZICK, A.; PIKIN, A.; RAPARIA, D.; RITTER, J.; ROSER, T.; RUSSO, T.; SNYDSTRUP, L.; WILINSKI, M.; ZALTSMAN, A.; ZHANG, S.

    2005-09-01

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linear accelerator (Linac). The highly successful development of an EBIS at Brookhaven National Laboratory (BNL) now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based preinjectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The proposed pre-injector system would also provide for a major enhancement in capability for the NASA Space Radiation Laboratory (NSRL), which utilizes heavy-ion beams from the RHIC complex. EBIS would allow for the acceleration of all important ion species for the NASA radiobiology program, such as, helium, argon, and neon which are unavailable with the present Tandem injector. In addition, the new system would allow for very rapid switching of ion species for

  4. Electron beam processed plasticized epoxy coatings for surface protection

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Mervat S. [National Center for Radiation Research and Technology, Nasr City (Egypt); Mohamed, Heba A., E-mail: hebaamohamed@gmail.com [National Research Center, Dokki (Egypt); Kandile, Nadia G. [University College for Girls, Ain Shams University (Egypt); Said, Hossam M.; Mohamed, Issa M. [National Center for Radiation Research and Technology, Nasr City (Egypt)

    2011-10-17

    Highlights: {center_dot} Coating formulations with EA 70%, HD 20%, and castor oil 10% under 1 Mrad pass{sup -1} irradiation dose showed the best adhesion and passed bending tests. {center_dot} The prepared EP-SF-An adduct improve anti-corrosion properties of coatings without any significant effect on physical, mechanical and chemical properties of the cured film. The optimum amount of aniline adduct as corrosion inhibitor was found to be 0.4 g for 100 g of coating formulation. {center_dot} The corrosion inhibition efficiency of the prepared adduct competed the commercial efficiency. - Abstract: Epoxy acrylate oligomer (EA) was plasticized by adding different plasticizers such as epoxidized soybean oil, glycerol and castor oil and cured by electron beam (EB). Different irradiation doses (1, 2.5 and 5 Mrad pass{sup -1}) were used in the curing process. The effect of both different irradiation doses and plasticizers on the end use performance properties of epoxy acrylate coating namely, pencil hardness, bending test, adhesion test, acid and alkali resistance test were studied. It was observed that incorporation of castor oil in epoxy acrylate diluted by 1,6-hexanediol diacrylate (HD) monomer with a ratio (EA 70%, HD 20%, castor oil 10%) under 1 Mrad pass{sup -1} irradiation dose improved the physical, chemical and mechanical properties of cured films than the other plasticizer. Sunflower free fatty acid was epoxidized in situ under well established conditions. The epoxidized sunflower free fatty acids (ESFA) were subjected to react with aniline in sealed ampoules under inert atmosphere at 140 deg. C. The produced adducts were added at different concentrations to epoxy acrylate coatings under certain EB irradiation dose and then evaluated as corrosion inhibitors for carbon steel surfaces in terms of weight loss measurements and corrosion resistance tests. It was found that, addition of 0.4 g of aniline adduct to 100 g epoxy acrylate formula may give the best corrosion

  5. The effect of electron beam welding on the creep rupture properties of a Nb-Zr-C alloy

    Science.gov (United States)

    Moore, T. J.; Titran, R. H.; Grobstein, T. L.

    1986-01-01

    Creep rupture tests of electron beam welded PWC-11 sheet were conducted at 1350 K. Full penetration, single pass welds were oriented transverse to the testing direction in 1 mm thick sheet. With this orientation, stress was imposed equally on the base metal, weld metal, and heat-affected zone. Tests were conducted in both the postweld annealed and aged conditions. Unwelded specimens with similar heat treatments were tested for comparative purposes. It was found that the weld region is stronger than the base metal for both the annealed and aged conditions and that the PWC-11 material is stronger in the annealed condition than in the aged condition.

  6. Spectroscopy on magnetically confined plasmas using electron beam ion trap spectrometers

    National Research Council Canada - National Science Library

    Graf, A T; Brockington, S; Horton, R; Howard, S; Hwang, D; Beiersdorfer, P; Clementson, J; Hill, D; May, M; Mclean, H; Wood, R; Bitter, M; Terry, J; Rowan, W L; Lepson, J K; Delgado-Aparicio, L

    2008-01-01

    Multiple spectrometers originally designed for and used at the University of California Lawrence Livermore National Laboratory's electron beam ion trap have found use at various magnetically confined plasma facilities...

  7. Computational modeling of stabilizing the instability of a relativistic electron beam in a dense plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bobylev, Yu. V.; Panin, V. A. [Tula Pedagogical University (Russian Federation); Kuzelev, M. V. [Moscow State University (Russian Federation); Rukhadze, A. A. [Russian Academy of Sciences, Prokhorov Institute of General Physics (Russian Federation)

    2011-12-15

    The nonlinear dynamics of the instability developed upon the interaction between a relativistic electron beam and a dense plasma as a function of the beam density is numerically modeled. The appropriate solutions are obtained and analyzed.

  8. Development of precision numerical controlled high vacuum electron beam welding machine

    CERN Document Server

    Li Shao Lin

    2002-01-01

    The structure, main technical parameters and characteristics of the precision numerical controlled high vacuum electron beam welding machine are introduced. The design principle, some features and solutions to some key technique problems of this new type machine are described

  9. Experimental Characterization of Electron Beam Welded SAE 5137H Thick Steel Plate

    Science.gov (United States)

    Kattire, Prakash; Bhawar, Valmik; Thakare, Sandeep; Patil, Sachin; Mane, Santosh; Singh, Rajkumar, Dr.

    2017-09-01

    Electron beam welding is known for its narrow weld zone with high depth to width ratio, less heat affected zone, less distortion and contamination. Electron beam welding is fusion welding process, where high velocity electrons impinge on material joint to be welded and kinetic energy of this electron is transformed into heat upon impact to fuse the material. In the present work electron beam welding of 60 mm thick SAE 5137H steel is studied. Mechanical and metallurgical properties of electron beam welded joint of SAE 5137H were evaluated. Mechanical properties are analysed by tensile, impact and hardness test. Metallurgical properties are investigated through optical and scanning electron microscope. The hardness traverse across weld zone shows HV 370-380, about 18% increase in the tensile strength and very low toughness of weld joint compared to parent metal. Microstructural observation shows equiaxed dendrite in the fusion zone and partial grain refinement was found in the HAZ.

  10. Effects of Metal Types on Residual Stress in Electron-Beam Welding Joints with Sheet Metals

    National Research Council Canada - National Science Library

    Nagai, Takuya; Kasai, Ryu; Ueno, Kunika; Mochizuki, Masahito; Suga, Tetsuo

    2015-01-01

    The effect of metal types on the residual stresses has been researched through X-ray stress measurement for the electron-beam welding joints made of sheet metals with a thickness of approximately 10 mm...

  11. Atomic radical abatement of organic impurities from electron beam deposited metallic structures

    NARCIS (Netherlands)

    Wnuk, J.D.; Gorham, J.M.; Rosenberg, S.G.; Madey, T.E.; Hagen, C.W.; Fairbrother, D.H.

    2010-01-01

    Focused electron beam induced processing (FEBIP) of volatile organometallic precursors has become an effective and versatile method of fabricating metal-containing nanostructures. However, the electron stimulated decomposition process responsible for the growth of these nanostructures traps much of

  12. Electron beam-plasma ionizing target for the production of neutron-rich nuclides

    CERN Document Server

    Panteleev, V.N; Fedorov, D.V; Ionan, A.M; Volkov, YU.M; Orlov, S.Yu; Moroz, F.V; Molkanov, P.L; Mezilev, K.A; Ivanov, V.S; Essabaa, S; Lau, C; Leroy, R; Lhersonneau, G; Villari, A.C.C; Stroe, L; 10.1016/j.nimb.2008.05.050

    2008-01-01

    The production of neutron rich Ag, In and Sn isotopes from a UC target of high density has been investigate at the IRIS facility. An electron beam-plasma ion source has been used to ionize the species produced.

  13. Experimental optimization of the 6-dimentional electron beam emittance at the NSLS SDL

    Science.gov (United States)

    Qian, H. J.; Murphy, J. B.; Shen, Y.; Tang, C. X.; Wang, X. J.

    2011-08-01

    Experimental optimization of the 6-dimensional electron beam emittance generated by a Magnesium (Mg) photocathode RF gun is presented in this report. A new electron beam optimization algorithm for a low charge (<100 pC) beam was experimentally demonstrated; where the electron beam velocity bunching inside the RF gun plays a critical role, and the transverse emittance as a function of the laser-RF timing jitter was experimentally characterized for the first time. A 20 pC electron beam was optimized to have a normalized slice emittance of 0.15 mm mrad and a longitudinal projected emittance of 3.9 ps keV. Furthermore, the upper limit of the measured thermal emittance—0.5 mm mrad per mm of the rms laser size, is about 50% lower than the theoretical prediction for a Mg cathode (Qian et al., 2010) [1].

  14. Trehalose glycopolymer resists allow direct writing of protein patterns by electron-beam lithography

    National Research Council Canada - National Science Library

    Bat, Erhan; Lee, Juneyoung; Lau, Uland Y; Maynard, Heather D

    2015-01-01

    .... Polymers with pendant trehalose units are shown to effectively crosslink to surfaces as negative resists, while at the same time providing stabilization to proteins during the vacuum and electron-beam irradiation steps...

  15. Morphological, Rheological, and Mechanical Properties of Polyamide 6/Polypropylene Blends Compatibilized by Electron-Beam Irradiation in the Presence of a Reactive Agent

    Directory of Open Access Journals (Sweden)

    Boo Young Shin

    2016-05-01

    Full Text Available An immiscible polyamide 6 (PA6/polypropylene (PP blend was compatibilized by electron-beam irradiation in the presence of reactive agent. Glycidyl methacrylate (GMA was chosen as a reactive agent for interfacial cross-copolymerization between dispersed PP and continuous PA6 phases initiated by electron-beam irradiation. The PA6/PP (80/20 mixture containing GMA was prepared using a twin-screw extruder, and then exposed to an electron-beam at various doses at room temperature to produce compatibilized PA6/PP blends. The morphological, rheological, and mechanical properties of blends produced were investigated. Morphology analysis revealed that the diameter of PP particles dispersed in PA6 matrix was decreased with increased irradiation dose and interfacial adhesion increased due to high surface area of treated PP particles. Complex viscosities (η* and storage moduli (G’ of blends increased with increasing irradiation dose and were higher than those of PA6 and PP. The complex viscosity of the blend irradiated at 200 kGy was 64 and 8 times higher than PA6 and PP, respectively. The elongation at break of blend irradiated less than 100 kGy was about twice that of PA6. Electron beam treatment improved the compatibility at the interface between PA6 and PP matrix in the presence of GMA.

  16. An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

    Directory of Open Access Journals (Sweden)

    Nasrollah Jabbari

    2009-03-01

    Full Text Available Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs, even for the same electron beam energy. The aims of this study were to simulate the NEPTUN 10PC linac electron beams and to calculate the photon contamination dose due to bremsstrahlung radiation in these beams using a Monte Carlo method. Materials and methods: A NEPTUN 10PC linac was simulated in its electron mode using the BEAMnrc code. This linac can provide three electron beam energies of 6, 8 and 10 MeV. Detailed information required for the simulation, including the geometry and materials of various components of the linac treatment head, was provided by the vender. For all simulations, the cut-off energies for electron and photon transport were set at ECUT=0.521 MeV and PCUT=0.010 MeV, respectively. The KS statistical test was used for validation of the simulated models. Then, relevant bremsstrahlung radiation doses for the three electron beam energies of the linac were calculated for the reference field using the Monte Carlo method.   Results: The KS test showed a good agreement between the calculated values (resulting from the simulations and the measured ones. The results showed that the amount of contaminated photon dose due to bremsstrahlung radiation from various components of the simulated linac at the surface of the phantom was between 0.2%-0.5% of the maximum dose for the three electron beam energies. Conclusion:  Considering the good agreement between the measured and simulated data, it can be concluded that the simulation method as well as the calculated bremsstrahlung doses have been made at a good level of accuracy and precision

  17. Simulation study of Hollow Electron Beam Collimation in HL-LHC.

    Energy Technology Data Exchange (ETDEWEB)

    Fitterer, M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Stancari, G. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Valishev, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Redaelli, S. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2016-10-05

    Collimation with hollow electron beams is currently one of the most promising concepts for active halo control in the HL-LHC. In this note we evaluate the performance of a hollow electron lens for different HL-LHC scenarios in terms of halo removal rates and the effect of profile imperfections of the electron beam on the proton beam core in case of a pulsed operation of the e-lens.

  18. Decomposition and decoloration of a direct dye by electron beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Vahdat, Ali [Amirkabir University of Technology, Textile Engineering Department, Tehran (Iran, Islamic Republic of); Bahrami, S.H., E-mail: hajirb@aut.ac.i [Amirkabir University of Technology, Textile Engineering Department, Tehran (Iran, Islamic Republic of); Arami, M. [Amirkabir University of Technology, Textile Engineering Department, Tehran (Iran, Islamic Republic of); Motahari, A. [Yazd University, Textile Engineering Department, Yazd (Iran, Islamic Republic of)

    2010-01-15

    The wastewaters released by textile industries to the environment contain hazardous compounds like toxic refractory dye stuff at high concentration. In this study, electron beam irradiation-induced decoloration and decomposition of C.I. Direct Black 22 aqueous solutions were investigated. The influences of absorbed doses and initial dye concentration on the percent of decoloration, COD and pH of the solutions are described. The results show that the direct dye solutions can be effectively degraded by electron beam irradiation.

  19. Electron Beam Welding: study of process capability and limitations towards development of nuclear components

    Science.gov (United States)

    Vadolia, Gautam R.; Premjit Singh, K.

    2017-04-01

    Electron Beam Welding (EBW) technology is an established and widely adopted technique in nuclear research and development area. Electron beam welding was thought of as a candidate process for ITER Vacuum Vessel Fabrication. Dhruva Reactor at BARC, Mumbai and Niobium superconducting accelerator cavity at BARC has adopted the EB welding technique as a fabrication route. Study of process capability and limitations based on available literature is consolidated in this short review paper.

  20. Determination of electron beam parameters by means of laser-Compton scattering

    Directory of Open Access Journals (Sweden)

    K. Chouffani

    2006-05-01

    Full Text Available Laser-Compton scattering (LCS experiments were carried out at the Idaho Accelerator Center using the 5 ns (FWHM and 22 MeV electron beam. The electron beam was brought to an approximate head-on collision with a 29 MW, 7 ns (FWHM, 10 Hz Nd:YAG laser. Clear and narrow x-ray peaks resulting from the interaction of relativistic electrons with the Nd:YAG laser second harmonic line at 532 nm were observed. We have developed a relatively new method of using LCS as a nonintercepting electron beam monitor. Our method focused on the variation of the shape of the LCS spectrum rather than the LCS intensity as a function of the observation angle in order to extract the electron beam parameters at the interaction region. The electron beam parameters were determined by making simultaneous fits to spectra taken across the LCS x-ray cone. This scan method allowed us also to determine the variation of LCS x-ray peak energies and spectral widths as a function of the detector angles. Experimental data show that in addition to being viewed as a potential bright, tunable, and quasimonochromatic x-ray source, LCS can provide important information on the electron beam pulse length, direction, energy, angular and energy spread. Since the quality of LCS x-ray peaks, such as degree of monochromaticity, peak energy and flux, depends strongly on the electron beam parameters, LCS can therefore be viewed as an important nondestructive tool for electron beam diagnostics.

  1. Chemical and Structural Stability of Lithium-Ion Battery Electrode Materials under Electron Beam

    OpenAIRE

    Feng Lin; Isaac M. Markus; Doeff, Marca M.; Xin, Huolin L.

    2014-01-01

    The investigation of chemical and structural dynamics in battery materials is essential to elucidation of structure-property relationships for rational design of advanced battery materials. Spatially resolved techniques, such as scanning/transmission electron microscopy (S/TEM), are widely applied to address this challenge. However, battery materials are susceptible to electron beam damage, complicating the data interpretation. In this study, we demonstrate that, under electron beam irradiati...

  2. Numerical simulation of inducing characteristics of high energy electron beam plasma for aerodynamics applications

    Science.gov (United States)

    Deng, Yongfeng; Jiang, Jian; Han, Xianwei; Tan, Chang; Wei, Jianguo

    2017-04-01

    The problem of flow active control by low temperature plasma is considered to be one of the most flourishing fields of aerodynamics due to its practical advantages. Compared with other means, the electron beam plasma is a potential flow control method for large scale flow. In this paper, a computational fluid dynamics model coupled with a multi-fluid plasma model is established to investigate the aerodynamic characteristics induced by electron beam plasma. The results demonstrate that the electron beam strongly influences the flow properties, not only in the boundary layers, but also in the main flow. A weak shockwave is induced at the electron beam injection position and develops to the other side of the wind tunnel behind the beam. It brings additional energy into air, and the inducing characteristics are closely related to the beam power and increase nonlinearly with it. The injection angles also influence the flow properties to some extent. Based on this research, we demonstrate that the high energy electron beam air plasma has three attractive advantages in aerodynamic applications, i.e. the high energy density, wide action range and excellent action effect. Due to the rapid development of near space hypersonic vehicles and atmospheric fighters, by optimizing the parameters, the electron beam can be used as an alternative means in aerodynamic steering in these applications.

  3. The potential of electron beam radiation for simultaneous surface modification and bioresorption control of PLLA.

    Science.gov (United States)

    Cairns, Marie-Louise; Dickson, Glenn R; Orr, John F; Farrar, David; Hardacre, Christopher; Sa, Jacinto; Lemoine, Patrick; Mughal, Muhammad Zeeshan; Buchanan, Fraser J

    2012-09-01

    Bioresorbable polymers have been widely investigated as materials exhibiting significant potential for successful application in the fields of tissue engineering and drug delivery. Further to the ability to control degradation, surface engineering of polymers has been highlighted as a key method central to their development. Previous work has demonstrated the ability of electron beam (e-beam) technology to control the degradation profiles and bioresorption of a number of commercially relevant bioresorbable polymers (poly-l-lactic acid (PLLA), L-lactide/DL-lactide co-polymer (PLDL) and poly(lactic-co-glycolic acid (PLGA)). This work investigates the further potential of e-beam technology to impart added biofunctionality through the manipulation of polymer (PLLA) surface properties. PLLA samples were subjected to e-beam treatments in air, with varying beam energies and doses. Surface characterization was then performed using contact angle analysis, X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and atomic force microscopy. Results demonstrated a significant increase in surface wettability post e-beam treatment. In correlation with this, XPS data showed the introduction of oxygen-containing functional groups to the surface of PLLA. Raman spectroscopy indicated chain scission in the near surface region of PLLA (as predicted). However, e-beam effects on surface properties were not shown to be dependent on beam energy or dose. E-beam irradiation did not seem to affect the surface roughness of PLLA as a direct consequence of the treatment. Copyright © 2012 Wiley Periodicals, Inc.

  4. High performance Si immersion gratings patterned with electron beam lithography

    Science.gov (United States)

    Gully-Santiago, Michael A.; Jaffe, Daniel T.; Brooks, Cynthia B.; Wilson, Daniel W.; Muller, Richard E.

    2014-07-01

    Infrared spectrographs employing silicon immersion gratings can be significantly more compact than spectro- graphs using front-surface gratings. The Si gratings can also offer continuous wavelength coverage at high spectral resolution. The grooves in Si gratings are made with semiconductor lithography techniques, to date almost entirely using contact mask photolithography. Planned near-infrared astronomical spectrographs require either finer groove pitches or higher positional accuracy than standard UV contact mask photolithography can reach. A collaboration between the University of Texas at Austin Silicon Diffractive Optics Group and the Jet Propulsion Laboratory Microdevices Laboratory has experimented with direct writing silicon immersion grating grooves with electron beam lithography. The patterning process involves depositing positive e-beam resist on 1 to 30 mm thick, 100 mm diameter monolithic crystalline silicon substrates. We then use the facility JEOL 9300FS e-beam writer at JPL to produce the linear pattern that defines the gratings. There are three key challenges to produce high-performance e-beam written silicon immersion gratings. (1) E- beam field and subfield stitching boundaries cause periodic cross-hatch structures along the grating grooves. The structures manifest themselves as spectral and spatial dimension ghosts in the diffraction limited point spread function (PSF) of the diffraction grating. In this paper, we show that the effects of e-beam field boundaries must be mitigated. We have significantly reduced ghost power with only minor increases in write time by using four or more field sizes of less than 500 μm. (2) The finite e-beam stage drift and run-out error cause large-scale structure in the wavefront error. We deal with this problem by applying a mark detection loop to check for and correct out minuscule stage drifts. We measure the level and direction of stage drift and show that mark detection reduces peak-to-valley wavefront error

  5. [Indeterminate cell histiocytosis - disappearance of skin infiltration following electron beam therapy and an application of 2-chlorodeoxyadenosine: case report].

    Science.gov (United States)

    Adam, Zdeněk; Ježová, Marta; Šlampa, Pavel; Křen, Leoš; Vašků, Vladimír; Koukalová, Renata; Řehák, Zdeněk; Pour, Luděk; Krejčí, Marta; Král, Zdeněk; Mayer, Jiří

    Indeterminate cell histiocytosis is a rare disease belonging to the group of malignant histiocytic diseases. The disease predominantly affects the skin. The disease appeared in the described patient at the age of 80 years. Morphs began to develop on the skin and rapidly spread over the whole body including the face. Only the hands and feet were left uncovered. The patients skin samples were taken from 2 sites for histological examination. The resulting conclusion was indeterminate cell histiocytosis. The treatment we chose was analogous to the procedures for Langerhans cell histiocytosis. We chose PUVA phototherapy as the first-line treatment. This treatment is frequently efficient for skin forms of Langerhans cell histiocytosis. In the described case, however, PUVA phototherapy did not influence the disease activity at all. As the second-line treatment, we used low-energy electron beam irradiation in the total dose of 36.2 Gy. This treatment had a positive impact, morphs began to diminish and slowly disappear from the skin. But they have not disappeared completely, therefore we assessed the treatment effect of the radiotherapy itself as partial remission of the disease. Within the third-line treatment, we used 2-chlorodeoxyadenosine in a dose of 5 mg/m2/per day, administered via subcutaneous injection over 5 consecutive days in monthly intervals. There were three cycles of this treatment administered overall. The treatment with 2-chlorodeoxyadenosine was tolerated without any adverse effects. The patient aged 82 years was only administered 3 cycles of 2-chlorodeoxyadenosine. When after the 3rd cycle the skin was free from any pathological morphs and only some pigmentation spots remained, we finished the treatment. The skin expressions of indeterminate cell histiocytosis completely disappeared after electron beam irradiation and the following administration of 3 cycles of 2-chlorodeoxyadenosine. The remission was short, however, after 6 months the disease recurred

  6. Surface Modification of Light Alloys by Low-Energy High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    X. D. Zhang

    2012-01-01

    Full Text Available This paper reviews results obtained by the research groups developing the low-energy high-current pulsed electron beam (LEHCPEB in Dalian (China and Metz (France on the surface treatment of light alloys. The pulsed electron irradiation induces an ultra-fast thermal cycle at the surface combined with the formation of thermal stress and shock waves. As illustrated for Mg alloys and Ti, this results in deep subsurface hardening (over several 100 μm which improves the wear resistance. The analysis of the top surface melted surface of light alloys also often witnesses evaporation and condensation of chemical species. This phenomenon can significantly modify the melt chemistry and was also suggested to lead to the development of specific solidification textures in the rapidly solidified layer. The potential use of the LEHCPEB technique for producing thermomechanical treatments under the so-called heating mode and, thus, modify the surface crystallographic texture, and enhance solid-state diffusion is also demonstrated in the case of the FeAl intermetallic compound.

  7. A study on the die steel surface modification by electron beam

    CERN Document Server

    Wu Ai Min; Zou Jian Xin; Hao Sheng Zhi; Dong Chuang; Zhang Ai Ming; Xu Tao

    2002-01-01

    A new surface modification technology-high current pulsed electron beam treatment method was applied to the surface of die steel to improve its properties. It has been shown that as a result of the HCPEB treatment, the most pronounced changes of the structure-phase state occur in the near-surface layers quenched from the liquid state, where the crystallization front velocity reaches its maximum. In these layers partial or complete dissolving of second phases and formation of over saturated solid solutions and ordered nano-sized structures may take place. This makes it possible to improve substantially the electrochemical and strength properties of the surface layer. The authors found that the thickness of remelt layer is about 10 mu m, and the sectional microhardness increased accompanied by the enhancement of the wear resistance of the material. After modification, the relative wear resistance of D2 steel have increased 5.63 times and that of H13 steel increased 11.76 times

  8. Characterization of ITO/CdO/glass thin films evaporated by electron beam technique

    Directory of Open Access Journals (Sweden)

    Hussein Abdel-Hafez Mohamed and Hazem Mahmoud Ali

    2008-01-01

    Full Text Available A thin buffer layer of cadmium oxide (CdO was used to enhance the optical and electrical properties of indium tin oxide (ITO films prepared by an electron-beam evaporation technique. The effects of the thickness and heat treatment of the CdO layer on the structural, optical and electrical properties of ITO films were carried out. It was found that the CdO layer with a thickness of 25 nm results in an optimum transmittance of 70% in the visible region and an optimum resistivity of 5.1×10−3 Ω cm at room temperature. The effect of heat treatment on the CdO buffer layer with a thickness of 25 nm was considered to improve the optoelectronic properties of the formed ITO films. With increasing annealing temperature, the crystallinity of ITO films seemed to improve, enhancing some physical properties, such as film transmittance and conductivity. ITO films deposited onto a CdO buffer layer heated at 450 °C showed a maximum transmittance of 91% in the visible and near-infrared regions of the spectrum associated with the highest optical energy gap of 3.61 eV and electrical resistivity of 4.45×10−4 Ω cm at room temperature. Other optical parameters, such as refractive index, extinction coefficient, dielectric constant, dispersion energy, single effective oscillator energy, packing density and free carrier concentration, were also studied.

  9. Electrodynamics of relativistic electron beam x-ray sources

    Science.gov (United States)

    Niknejadi, Pardis

    Probing matter at atomic scales provides invaluable information about its structure; as a result interest in sources of x-rays and gamma-rays with high spectral resolution, low angular divergence and small source size has been on the rise. Explorations in this domain require x-ray or gamma-ray sources with high brightness. In the past decade, relativistic electron sources such as synchrotron rings and free electron lasers have proven to be the best technology available for the production of such beams. We1 start with an introduction to the physics of radiation and provide a summary of the theoretical grounds this work is based on. This dissertation is dedicated to different aspects of both fundamental processes of radiation in relativistic electron sources, and critical control and diagnostics that are required for the operation of these sources. Therefore this work is broken into two main parts. In the first part, the electron source that is currently set up at University of Hawai`i at Manoa will be introduced in detail. This source has unique capabilities as it is an inverse-Compton scattering (ICS) source that uses a free electron laser (FEL) with pulses of picosecond duration at ˜ 3 GHz rate for production of a coherent/semi-coherent x-ray beam by means of an optical cavity. After introducing the essential elements of the system and what was achieved prior to this work, we will focus on the requirements for achieving an optimum electron beam matched for the operation of the system which is the main focus of part I of this dissertation. The transport beam line of our system is unique and complex. For this reason, a simulation module has been developed for the study and delivery of an optimal beam. We will discuss the capabilities of this system and its compatibility with other elements that were already installed on the beam line. Finally, we will present results and experimental data as well as guidelines for future operation of the system when the microwave

  10. Strengthening effect of nano-scaled precipitates in Ta alloying layer induced by high current pulsed electron beam

    Science.gov (United States)

    Tang, Guangze; Luo, Dian; Fan, Guohua; Ma, Xinxin; Wang, Liqin

    2017-05-01

    In this study, the combination of magnetron sputtering and high current pulsed electron beam are used for surface alloying treatment of Ta film on high speed steel. And the Ta alloying layer is about 6 μm. After tempering treatment, TaC phase forms in Ta alloying layer when the treated temperature is over 823 K. Through the TEM and HRTEM observation, a large amount of nano-scaled precipitates (mean diameter 5-8 nm) form within the δ-Fe grain in Ta alloying layer after tempering treatment and these nano-scaled precipitates are confirmed as TaC particles, which contribute to the strengthening effect of the surface alloying layer. The hardness of tempered alloying layer can reach to 18.1 GPa when the treated temperature is 823 K which increase by 50% comparing with the untreated steel sample before surface alloying treatment.

  11. Study on Nanostructures Induced by High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    Bo Gao

    2012-01-01

    Full Text Available Four techniques using high-current pulsed electron beam (HCPEB were proposed to obtain surface nanostructure of metal and alloys. The first method involves the distribution of several fine Mg nanoparticles on the top surface of treated samples by evaporation of pure Mg with low boiling point. The second technique uses superfast heating, melting, and cooling induced by HCPEB irradiation to refine the primary phase or the second phase in alloys to nanosized uniform distributed phases in the matrix, such as the quasicrystal phase Mg30Zn60Y10 in the quasicrystal alloy Mg67Zn30Y3. The third technique involves the refinement of eutectic silicon phase in hypereutectic Al-15Si alloys to fine particles with the size of several nanometers through solid solution and precipitation refinement. Finally, in the deformation zone induced by HCPEB irradiation, the grain size can be refined to several hundred nanometers, such as the grain size of the hypereutectic Al-15Si alloys in the deformation zone, which can reach ~400 nm after HCPEB treatment for 25 pulses. Therefore, HCPEB technology is an efficient way to obtain surface nanostructure.

  12. In situ growth optimization in focused electron-beam induced deposition

    Directory of Open Access Journals (Sweden)

    Paul M. Weirich

    2013-12-01

    Full Text Available We present the application of an evolutionary genetic algorithm for the in situ optimization of nanostructures that are prepared by focused electron-beam-induced deposition (FEBID. It allows us to tune the properties of the deposits towards the highest conductivity by using the time gradient of the measured in situ rate of change of conductance as the fitness parameter for the algorithm. The effectiveness of the procedure is presented for the precursor W(CO6 as well as for post-treatment of Pt–C deposits, which were obtained by the dissociation of MeCpPt(Me3. For W(CO6-based structures an increase of conductivity by one order of magnitude can be achieved, whereas the effect for MeCpPt(Me3 is largely suppressed. The presented technique can be applied to all beam-induced deposition processes and has great potential for a further optimization or tuning of parameters for nanostructures that are prepared by FEBID or related techniques.

  13. Intraoperative Electron-Beam Radiation Therapy for Pediatric Ewing Sarcomas and Rhabdomyosarcomas: Long-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Sole, Claudio V., E-mail: csole@iram.cl [Department of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); School of Medicine, Complutense University, Madrid (Spain); Calvo, Felipe A. [School of Medicine, Complutense University, Madrid (Spain); Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Polo, Alfredo [Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Madrid (Spain); Cambeiro, Mauricio [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain); Gonzalez, Carmen [School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Desco, Manuel [School of Medicine, Complutense University, Madrid (Spain); Department of Experimental Surgery and Medicine, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Martinez-Monge, Rafael [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain)

    2015-08-01

    Purpose: To assess long-term outcomes and toxicity of intraoperative electron-beam radiation therapy (IOERT) in the management of pediatric patients with Ewing sarcomas (EWS) and rhabdomyosarcomas (RMS). Methods and Materials: Seventy-one sarcoma (EWS n=37, 52%; RMS n=34, 48%) patients underwent IOERT for primary (n=46, 65%) or locally recurrent sarcomas (n=25, 35%) from May 1983 to November 2012. Local control (LC), overall survival (OS), and disease-free survival were estimated using Kaplan-Meier methods. For survival outcomes, potential associations were assessed in univariate and multivariate analyses using the Cox proportional hazards model. Results: After a median follow-up of 72 months (range, 4-310 months), 10-year LC, disease-free survival, and OS was 74%, 57%, and 68%, respectively. In multivariate analysis after adjustment for other covariates, disease status (P=.04 and P=.05) and R1 margin status (P<.01 and P=.04) remained significantly associated with LC and OS. Nine patients (13%) reported severe chronic toxicity events (all grade 3). Conclusions: A multimodal IOERT-containing approach is a well-tolerated component of treatment for pediatric EWS and RMS patients, allowing reduction or substitution of external beam radiation exposure while maintaining high local control rates.

  14. The network and properties of the NR/SBR vulcanizate modified by electron beam irradiation

    Science.gov (United States)

    Shen, Jing; Wen, Shipeng; Du, Yishi; Li, Ning; Zhang, Liqun; Yang, Yusheng; Liu, Li

    2013-11-01

    A natural rubber/styrene butadiene rubber (NR/SBR) vulcanizate filled with carbon black was modified by high-energy electron beam (EB) irradiation in this work. The crosslinked structure was studied by a special chemical probe method. The influence of EB irradiation on mechanical properties, filler network, and dynamic properties including abrasion resistance, rolling resistance, and wet skid resistance was also investigated. The results revealed that the crosslink structure significantly changed after EB treatment, indicating that the amount of poly- and di-sulfide crosslinked bonds decreased and that of mono-sulfide bonds increased. The polymer-filler interaction was enhanced after EB irradiation. An EB dose of 600 kGy reduced the abrasion loss of the NR/SBR vulcanizate, and one of 300 kGy reduced the rolling resistance by 11.4%. Meanwhile, EB doses below 200 kGy had no obvious effect on the wet skid resistance. This EB-modified NR/SBR vulcanizate can be used to prepare high-performance tires with good abrasion resistance and low rolling resistance.

  15. Microscopic kinetic analysis of space-charge induced optical microbunching in a relativistic electron beam

    Directory of Open Access Journals (Sweden)

    Agostino Marinelli

    2010-11-01

    Full Text Available Longitudinal space-charge forces from density fluctuations generated by shot noise can be a major source of microbunching instability in relativistic high brightness electron beams. The gain in microbunching due to this effect is broadband, extending at least up to optical frequencies, where the induced structure on the beam distribution gives rise to effects such as coherent optical transition radiation. In the high-frequency regime, theoretical and computational analyses of microbunching formation require a full three-dimensional treatment. In this paper we address the problem of space-charge induced optical microbunching formation in the high-frequency limit when transverse thermal motion due to finite emittance is included for the first time. We derive an analytical description of this process based on the beam’s plasma dielectric function. We discuss the effect of transverse temperature on the angular distribution of microbunching gain and its connection to the physics of Landau damping in longitudinal plasma oscillations. Application of the theory to a relevant experimental scenario is discussed. The analytical results obtained are then compared to the predictions arising from high resolution three-dimensional molecular dynamics simulations.

  16. Electron Beam Melting Manufacturing Technology for Individually Manufactured Jaw Prosthesis: A Case Report.

    Science.gov (United States)

    Suska, Felicia; Kjeller, Göran; Tarnow, Peter; Hryha, Eduard; Nyborg, Lars; Snis, Anders; Palmquist, Anders

    2016-08-01

    In the field of maxillofacial reconstruction, additive manufacturing technologies, specifically electron beam melting (EBM), offer clinicians the potential for patient-customized design of jaw prostheses, which match both load-bearing and esthetic demands. The technique allows an innovative, functional design, combining integrated porous regions for bone ingrowth and secondary biological fixation with solid load-bearing regions ensuring the biomechanical performance. A patient-specific mandibular prosthesis manufactured using EBM was successfully used to reconstruct a patient's mandibular defect after en bloc resection. Over a 9-month follow-up period, the patient had no complications. A short operating time, good esthetic outcome, and high level of patient satisfaction as measured by quality-of-life questionnaires-the European Organisation for Research and Treatment of Cancer QLQ-C30 (30-item quality-of-life core questionnaire) and H&N35 (head and neck cancer module)-were reported for this case. Individually planned and designed EBM-produced prostheses may be suggested as a possible future alternative to fibular grafts or other reconstructive methods. However, the role of porosity, the role of geometry, and the optimal combination of solid and porous parts, as well as surface properties in relation to soft tissues, should be carefully evaluated in long-term clinical trials. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Toxicity reduction for pharmaceuticals mixture in water by electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Boiani, Nathalia Fonseca; Tominaga, Flavio Kiyoshi; Borrely, Sueli Ivone, E-mail: flavio_tominaga@hotmail.com, E-mail: sborrely@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The incorrect disposal of products is committing the environment quality once the aquatic environment is the main vehicle for dispersion of pollutants. Among the highlighted contaminants there are the pharmaceuticals, which are also released to the aquatic environment through the domestic sewage, hospitals and effluents. The monitoring of these pharmaceuticals in the environment has grown, showing many of them as persistent pollutants. Pharmaceuticals from different therapeutic classes have been detected in domestic sewage, surface water and groundwater around the world. Several studies evidenced Fluoxetine Hydrochloride residues in waters. Another important product is the Propranolol, used for heart disease treatments as far as fluoxetine is applied for treating mental diseases. The objective of this study was to apply the radiation processing for the abatement of pollutant in waters. Electron beam accelerator was used during irradiation of the mixture (Propranolol + Fluoxetine Hydrochloride) in aqueous solution. Acute toxicity assays were carried out for Vibrio fischeri marine bacterium, 15 minutes exposure. The results showed that irradiation (2.5kGy and 5.0kGy) enhanced the average effective concentration of the mixture, which means reduction of toxicity (56.34%, 55.70% respectively). Inverse effect was obtained with 7.5 kGy and 10 kGy. (author)

  18. Large Pulsed Electron Beam Welded Percolation Networks of Silver Nanowires for Transparent and Flexible Electrodes.

    Science.gov (United States)

    Kim, Jisoo; Nam, Yun Seok; Song, Myoung Hoon; Park, Hyung Wook

    2016-08-17

    Mechanical properties of transparent electrodes, including flexibility, are important in flexible electronics for sustaining electrical conductivity under bending with small radius of curvature. Low contact resistance of junctions in metal nanowire percolation networks is the most important factor to produce electrodes with excellent optical, electrical and mechanical performance. Here, we report the fabrication of welded silver nanowire percolation networks using large pulsed electron beam (LPEB) irradiation as a welding process of silver nanowires (AgNWs). It results in modification of electrical and mechanical properties because of the low contact resistance at welded junctions. Consequently, the flexible and transparent AgNW electrodes fabricated by LPEB irradiation showed lower sheet resistance of 12.63 Ω sq(-1) at high transmittance of 93% (at 550 nm), and superb mechanical flexibility, compared with other AgNW electrodes prepared by thermal treatement and without any treatment. Polymer light-emitting diodes (PLEDs) using AgNWs by LPEB irradiation were fabricated to confirm that the AgNW electrode by LPEB irradiation was able to become alternative to indium tin oxide (ITO) and they showed good device performance as a maximum luminous efficiency of 7.37 cd A(-1), and excellent mechanical flexibility under bending with small radius of curvature.

  19. Electron beam for preservation of biodeteriorated cultural heritage paper-based objects

    Science.gov (United States)

    Chmielewska-Śmietanko, Dagmara; Gryczka, Urszula; Migdał, Wojciech; Kopeć, Kamil

    2018-02-01

    Unsuitable storage conditions or accidents such as floods can present a serious threat for large quantities of book making them prone to attack by harmful microorganisms. The microbiological degradation of archives and book collections can be efficiently inhibited with irradiation processing. Application of EB irradiation to book and archive collections can also be a very effective alternative to the commonly used ethylene oxide treatment, which is toxic to the human and natural environment. In this study was evaluated the influence of EB irradiation used for microbiological decontamination process on paper-based objects. Three different kinds of paper (Whatman CHR 1, office paper and newsprint paper) were treated with 0.4, 1, 2, 5, 10 and 25 kGy electron beam irradiation. Optical and mechanical properties of different sorts of paper treated with e-beam, before and after the radiation process were studied. These results, which correlated with absorbed radiation doses effective for the elimination of Aspergillus niger (A. niger) allowed to determine that EB irradiation with absorbed radiation dose of 5 kGy ensures safe decontamination of different sorts of paper-based objects.

  20. Time-Dependent Variations in Structure of Sheep Wool Irradiated by Electron Beam

    Directory of Open Access Journals (Sweden)

    Zuzana Hanzlíková

    2017-01-01

    Full Text Available Wool scoured in tap water with no special degreasing and containing a balanced humidity responding to usual laboratory conditions was irradiated by accelerated electron beam in the range of 0–350 kGy dose. Time variations of the wool structure were measured using FTIR, Raman, and EPR spectroscopy. The aim was to determine whether preexposure treatment of the wool, as well as postexposure time, affects the properties of the irradiated wool. Reactive products such as S-sulfonate, cystine monoxide, cystine dioxide, cysteic acid, disulphides, and carboxylates displayed a considerable fluctuation in quantity depending on both the absorbed dose and time. Mutual transformations of S-oxidized products into cysteic acid appeared to be faster than those in dry and degreased wool assuming that the present humidity inside the fibres is decisive as an oxygen source. EPR results indicated a longer lifetime for free radicals induced by lower doses compared with the radicals generated by higher ones. The pattern of the conformational composition of the secondary structure (α-helix, β-sheet, random, and residual conformations also showed a large variability depending on absorbed dose as well as postexposure time. The most stable secondary structure was observed in nonirradiated wool but even this showed a small but observable change after a longer time, too.