WorldWideScience

Sample records for electron intraoperative therapy

  1. Intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Dobelbower Junior, R.R.

    1987-01-01

    A briefly history of intraoperative radiotherapy is presented. The equipment used is described and the treatment with superficial X-ray beams, orthovoltage X-ray beams and megavoltage electron beams are discussed. The effect on normal tissues and the clinical use of intraoperative radiotherapy in several Kind of cancer is studied. (M.A.C.) [pt

  2. Intraoperative electron beam radiation therapy (IOEBRT) for carcinoma of the exocrine pancreas

    International Nuclear Information System (INIS)

    Dobelbower, R.R. Jr.; Konski, A.A.; Merrick, H.W. III; Bronn, D.G.; Schifeling, D.; Kamen, C.

    1991-01-01

    The abdominal cavities of 50 patients were explored in a specially constructed intraoperative radiotherapy operating amphitheater at the Medical College of Ohio. Twenty-six patients were treated with intraoperative and postoperative precision high dose external beam therapy, 12 with intraoperative irradiation but no external beam therapy, and 12 with palliative surgery alone. All but two patients completed the postoperative external beam radiation therapy as initially prescribed. The median survival time for patients treated with palliative surgery alone was 4 months, and that for patients treated with intraoperative radiotherapy without external beam therapy was 3.5 months. Patients undergoing intraoperative irradiation and external beam radiation therapy had a median survival time of 10.5 months. Four patients died within 30 days of surgery and two patients died of gastrointestinal hemorrhage 5 months posttreatment

  3. Evaluation of LiF:Mg,Ti (TLD-100 for Intraoperative Electron Radiation Therapy Quality Assurance.

    Directory of Open Access Journals (Sweden)

    Raffaele Liuzzi

    Full Text Available Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs response to intraoperative electron radiation therapy (IOERT beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters.LiF:Mg,Ti dosimeters (TLD-100 were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy.The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05.This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.

  4. Phase space determination from measured dose data for intraoperative electron radiation therapy.

    Science.gov (United States)

    Herranz, E; Herraiz, J L; Ibáñez, P; Pérez-Liva, M; Puebla, R; Cal-González, J; Guerra, P; Rodríguez, R; Illana, C; Udías, J M

    2015-01-07

    A procedure to characterize beams of a medical linear accelerator for their use in Monte Carlo (MC) dose calculations for intraoperative electron radiation therapy (IOERT) is presented. The procedure relies on dose measurements in homogeneous media as input, avoiding the need for detailed simulations of the accelerator head. An iterative algorithm (EM-ML) has been employed to extract the relevant details of the phase space (PHSP) of the particles coming from the accelerator, such as energy spectra, spatial distribution and angle of emission of particles. The algorithm can use pre-computed dose volumes in water and/or air, so that the machine-specific tuning with actual data can be performed in a few minutes. To test the procedure, MC simulations of a linear accelerator with typical IOERT applicators and energies, have been performed and taken as reference. A solution PHSP derived from the dose produced by the simulated accelerator has been compared to the reference PHSP. Further, dose delivered by the simulated accelerator for setups not included in the fit of the PHSP were compared to the ones derived from the solution PHSP. The results show that it is possible to derive from dose measurements PHSP accurate for IOERT MC dose estimations.

  5. Stability of a mobile electron linear accelerator system for intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Beddar, A. Sam

    2005-01-01

    The flexibility of mobile electron accelerators, which are designed to be transported to an operating room and plugged into a normal 3-phase outlet, make them ideal for use in intraoperative radiation therapy. However, their transportability may cause trepidation among potential users, who may question the stability of such an accelerator over a period of use. In order to address this issue, we have studied the short-term stability of the Mobetron system over 20 daily quality assurance trials. Variations in output generally varied within ±2% for the four energies produced by the unit (4, 6, 9, and 12 MeV) and changes in energy produced an equivalent shift of less than 1 mm on the depth-dose curve. Hours of inactivity, with the Mobetron powered on for use either throughout the day or overnight, led to variations in output of about 1%. Finally, we have tested the long-term stability of the absolute dose output of the Mobetron, which showed a change of about 1% per year

  6. Intraoperative Electron-Beam Radiation Therapy for Pediatric Ewing Sarcomas and Rhabdomyosarcomas: Long-Term Outcomes

    International Nuclear Information System (INIS)

    Sole, Claudio V.; Calvo, Felipe A.; Polo, Alfredo; Cambeiro, Mauricio; Gonzalez, Carmen; Desco, Manuel; Martinez-Monge, Rafael

    2015-01-01

    Purpose: To assess long-term outcomes and toxicity of intraoperative electron-beam radiation therapy (IOERT) in the management of pediatric patients with Ewing sarcomas (EWS) and rhabdomyosarcomas (RMS). Methods and Materials: Seventy-one sarcoma (EWS n=37, 52%; RMS n=34, 48%) patients underwent IOERT for primary (n=46, 65%) or locally recurrent sarcomas (n=25, 35%) from May 1983 to November 2012. Local control (LC), overall survival (OS), and disease-free survival were estimated using Kaplan-Meier methods. For survival outcomes, potential associations were assessed in univariate and multivariate analyses using the Cox proportional hazards model. Results: After a median follow-up of 72 months (range, 4-310 months), 10-year LC, disease-free survival, and OS was 74%, 57%, and 68%, respectively. In multivariate analysis after adjustment for other covariates, disease status (P=.04 and P=.05) and R1 margin status (P<.01 and P=.04) remained significantly associated with LC and OS. Nine patients (13%) reported severe chronic toxicity events (all grade 3). Conclusions: A multimodal IOERT-containing approach is a well-tolerated component of treatment for pediatric EWS and RMS patients, allowing reduction or substitution of external beam radiation exposure while maintaining high local control rates

  7. Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators

    International Nuclear Information System (INIS)

    Ciocca, Mario; Cantone, Marie-Claire; Veronese, Ivan; Cattani, Federica; Pedroli, Guido; Molinelli, Silvia; Vitolo, Viviana; Orecchia, Roberto

    2012-01-01

    Purpose: Failure mode and effects analysis (FMEA) represents a prospective approach for risk assessment. A multidisciplinary working group of the Italian Association for Medical Physics applied FMEA to electron beam intraoperative radiation therapy (IORT) delivered using mobile linear accelerators, aiming at preventing accidental exposures to the patient. Methods and Materials: FMEA was applied to the IORT process, for the stages of the treatment delivery and verification, and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, based on the product of three parameters (severity, frequency of occurrence and detectability, each ranging from 1 to 10); 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results: Twenty-four subprocesses were identified. Ten potential failure modes were found and scored, in terms of RPN, in the range of 42–216. The most critical failure modes consisted of internal shield misalignment, wrong Monitor Unit calculation and incorrect data entry at treatment console. Potential causes of failure included shield displacement, human errors, such as underestimation of CTV extension, mainly because of lack of adequate training and time pressures, failure in the communication between operators, and machine malfunctioning. The main effects of failure were represented by CTV underdose, wrong dose distribution and/or delivery, unintended normal tissue irradiation. As additional safety measures, the utilization of a dedicated staff for IORT, double-checking of MU calculation and data entry and finally implementation of in vivo dosimetry were suggested. Conclusions: FMEA appeared as a useful tool for prospective evaluation of patient safety in radiotherapy

  8. Intraoperative radiation therapy using mobile electron linear accelerators: Report of AAPM Radiation Therapy Committee Task Group No. 72

    International Nuclear Information System (INIS)

    Sam Beddar, A.; Biggs, Peter J.; Chang Sha; Ezzell, Gary A.; Faddegon, Bruce A.; Hensley, Frank W.; Mills, Michael D.

    2006-01-01

    Intraoperative radiation therapy (IORT) has been customarily performed either in a shielded operating suite located in the operating room (OR) or in a shielded treatment room located within the Department of Radiation Oncology. In both cases, this cancer treatment modality uses stationary linear accelerators. With the development of new technology, mobile linear accelerators have recently become available for IORT. Mobility offers flexibility in treatment location and is leading to a renewed interest in IORT. These mobile accelerator units, which can be transported any day of use to almost any location within a hospital setting, are assembled in a nondedicated environment and used to deliver IORT. Numerous aspects of the design of these new units differ from that of conventional linear accelerators. The scope of this Task Group (TG-72) will focus on items that particularly apply to mobile IORT electron systems. More specifically, the charges to this Task Group are to (i) identify the key differences between stationary and mobile electron linear accelerators used for IORT (ii) describe and recommend the implementation of an IORT program within the OR environment, (iii) present and discuss radiation protection issues and consequences of working within a nondedicated radiotherapy environment, (iv) describe and recommend the acceptance and machine commissioning of items that are specific to mobile electron linear accelerators, and (v) design and recommend an efficient quality assurance program for mobile systems

  9. Monte Carlo design, dosimetry and radiation protection studies for a new mobile electron accelerator for intraoperative radiation therapy (IORT)

    International Nuclear Information System (INIS)

    Wysocka-Rabin, A.

    2013-01-01

    Intraoperative radiation therapy (IORT) delivers a large, single fraction dose of radiation to a surgically exposed tumor or tumor bed. This presentation reviews the design concept and dosimetry characteristics of an electron beam forming system for an IORT accelerator, with special emphasis on beam flatness, X-ray contamination and protecting personnel from dose delivered outside the treatment field. The Monte Carlo code, BEAMnrc/EGSnrc, was used to design, verify and optimize the electron beam forming system for two different docking methods with circular metallic applicators. Calculations of therapeutic beam characteristics were performed at the patient surface. Findings were obtained for initially mono-energetic electron beams with an energy range from 4 to 12 MeV, SSD equal to 60 cm, and circular applicators with diameters from 3 to 12 cm. The aim was to build an electron beam forming system (collimators, scattering-flattening foils, applicators) that is universal for all beam energy and field diameters described above

  10. Design and dosimetry characteristics of a commercial applicator system for intra-operative electron beam therapy utilizing ELEKTA Precise accelerator.

    Science.gov (United States)

    Nevelsky, Alexander; Bernstein, Zvi; Bar-Deroma, Raquel; Kuten, Abraham; Orion, Itzhak

    2010-07-19

    The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead collimators. A telescopic device allows changing of source-to-surface distance (SSD). All measurements were performed for 6, 9, 12 and 18 MeV electron energies. Output factors and percentage depth doses (PDD) were measured in a water phantom using a plane-parallel ion chamber. Isodose contours and radiation leakage were measured using a solid water phantom and radiographic films. The dependence of PDD on SSD was checked for the applicators with the smallest and the biggest diameters. SSD dependence of the output factors was measured. Hardcopies of PDD and isodose contours were prepared to help the team during the procedure on deciding applicator size and energy to be chosen. Applicator output factors are a function of energy, applicator size and applicator type. Dependence of SSD correction factors on applicator size and applicator type was found to be weak. The same SSD correction will be applied for all applicators in use for each energy. The radiation leakage through the applicators is clinically acceptable. The applicator system enables effective collimation of electron beams for IORT. The data presented are sufficient for applicator, energy and monitor unit selection for IORT treatment of a patient.

  11. Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios

    International Nuclear Information System (INIS)

    García-Vázquez, V; Marinetto, E; Santos-Miranda, J A; Calvo, F A; Desco, M; Pascau, J

    2013-01-01

    Intra-operative electron radiation therapy (IOERT) combines surgery and ionizing radiation applied directly to an exposed unresected tumour mass or to a post-resection tumour bed. The radiation is collimated and conducted by a specific applicator docked to the linear accelerator. The dose distribution in tissues to be irradiated and in organs at risk can be planned through a pre-operative computed tomography (CT) study. However, surgical retraction of structures and resection of a tumour affecting normal tissues significantly modify the patient's geometry. Therefore, the treatment parameters (applicator dimension, pose (position and orientation), bevel angle, and beam energy) may require the original IOERT treatment plan to be modified depending on the actual surgical scenario. We propose the use of a multi-camera optical tracking system to reliably record the actual pose of the IOERT applicator in relation to the patient's anatomy in an environment prone to occlusion problems. This information can be integrated in the radio-surgical treatment planning system in order to generate a real-time accurate description of the IOERT scenario. We assessed the accuracy of the applicator pose by performing a phantom-based study that resembled three real clinical IOERT scenarios. The error obtained (2 mm) was below the acceptance threshold for external radiotherapy practice, thus encouraging future implementation of this approach in real clinical IOERT scenarios. (paper)

  12. Outcome of patients with local recurrent gynecologic malignancies after resection combined with intraoperative electron radiation therapy (IOERT)

    International Nuclear Information System (INIS)

    Arians, Nathalie; Foerster, Robert; Rom, Joachim; Uhl, Matthias; Roeder, Falk; Debus, Jürgen; Lindel, Katja

    2016-01-01

    Treatment of recurrent gynecologic cancer is a challenging issue. Aim of the study was to investigate clinical features and outcomes of patients with recurrent gynecologic malignancies who underwent resection including IOERT (intraoperative electron radiation therapy) with regard to clinical outcome and potential predictive factors or subgroups that benefit most from this radical treatment regime. A total of 36 patients with recurrent gynecologic malignancies (cervical (n = 18), endometrial (n = 12) or vulvar cancer (n = 6)) were retrospectively identified through hospital databases in accordance with institutional ethical policies. Patient characteristics and outcomes were assessed. Survival data was analyzed using the Kaplan-Meier-method and log-rank-test, categorical variables were analyzed with chi-square-method. For the entire cohort 1-/2-/5-year Overall Survival (OS) was 65.3 %/36.2 %/21.7 %. Patients with endometrial, cervical, and vulvar carcinoma had a 1-/2-/5-year OS of 83.3 %/62.5 %/50 %, 44.5 %/25.4 %/6.4 %, and 83.3 %/16.7 %/16.7 %, respectively. Patients with endometrial carcinoma showed a significantly better OS (p = 0.038). 1-/2-/5-year Local Progression-free Survival (LPFS) for the entire cohort was 44.1 %/28 %/21 % with 76.2 %/61 %/40.6 % for endometrial, 17.2 %/0 %/0 % for cervical, and 40 %/20 %/20 % for vulvar cancer, respectively. Patients with endometrial cancer showed a significantly (p = 0.017) and older patients a trend (p = 0.059) for a better LPFS. 1-/2-/5-year Distant Progression-free Survival (DPFS) for the entire cohort was 53.1 %/46.5 %/38.7 % with 74.1 %/74.1 %/74.1 % for endometrial, 36.7 %/36.7 %/0 % for cervical, and 60 %/30 %/30 % for vulvar cancer, respectively. There was a significantly better DPFS for older patients (p = 0.015) and a trend for a better DPFS for patients with endometrial carcinoma (p = 0.075). The radical procedure of resection combined with IOERT seems to be a valid curative treatment option for patients with

  13. A non-docking intraoperative electron beam applicator system

    International Nuclear Information System (INIS)

    Palta, J.R.; Suntharalingam, N.

    1989-01-01

    A non-docking intraoperative radiation therapy electron beam applicator system for a linear accelerator has been designed to minimize the mechanical, electrical, and tumor visualization problems associated with a docking system. A number of technical innovations have been used in the design of this system. These include: (a) a new intraoperative radiation therapy cone design that gives a better dose uniformity in the treatment volume at all depths; (b) a collimation system which reduces the leakage radiation dose to tissues outside the intraoperative radiation therapy cone; (c) a non-docking system with a translational accuracy of 2 mm and a rotational accuracy of 0.5 degrees; and (d) a rigid clamping system for the cones. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented

  14. Intraoperative electron beam radiation therapy: technique, dosimetry, and dose specification: report of task force 48 of the radiation therapy committee, American association of physicists in medicine

    International Nuclear Information System (INIS)

    Palta, Jatinder R.; Biggs, Peter J.; Hazle, John D.; Huq, M. Saiful; Dahl, Robert A.; Ochran, Timothy G.; Soen, Jerry; Dobelbower, Ralph R.; McCullough, Edwin C.

    1995-01-01

    Intraoperative radiation therapy (IORT) is a treatment modality whereby a large single dose of radiation is delivered to a surgically open, exposed cancer site. Typically, a beam of megavoltage electrons is directed at an exposed tumor or tumor bed through a specially designed applicator system. In the last few years, IORT facilities have proliferated around the world. The IORT technique and the applicator systems used at these facilities vary greatly in sophistication and design philosophy. The IORT beam characteristics vary for different designs of applicator systems. It is necessary to document the existing techniques of IORT, to detail the dosimetry data required for accurate delivery of the prescribed dose, and to have a uniform method of dose specification for cooperative clinical trials. The specific charge to the task group includes the following: (a) identify the multidisciplinary IORT team, (b) outline special considerations that must be addressed by an IORT program, (c) review currently available IORT techniques, (d) describe dosimetric measurements necessary for accurate delivery of prescribed dose, (e) describe dosimetric measurements necessary in documenting doses to the surrounding normal tissues, (f) recommend quality assurance procedures for IORT, (g) review methods of treatment documentation and verification, and (h) recommend methods of dose specification and recording for cooperative clinical trials

  15. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    International Nuclear Information System (INIS)

    Sole, C.V.; Calvo, F.A.; Lozano, M.A.; Gonzalez-Sansegundo, C.; Gonzalez-Bayon, L.; Alvarez, A.; Lizarraga, S.; Garcia-Sabrido, J.L.

    2014-01-01

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  16. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    Energy Technology Data Exchange (ETDEWEB)

    Sole, C.V. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Instituto de Radiomedicina, Service of Radiation Oncology, Santiago (Chile); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Calvo, F.A. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lozano, M.A.; Gonzalez-Sansegundo, C. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Gonzalez-Bayon, L. [Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Alvarez, A. [Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lizarraga, S. [Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Garcia-Sabrido, J.L. [Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain)

    2014-02-15

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  17. INTRAOPERATIVE PHOTODYNAMIC THERAPY FOR METASTATIC PERITONEAL TUMORS

    Directory of Open Access Journals (Sweden)

    E. A. Suleimanov

    2016-01-01

    Full Text Available This review is devoted to the cytoreductive treatment of malignant tumors of the abdominal organs. The actuality of the issue is determined both by increase of the incidence of abdominal cancer in Russia and in majority of developed countries and by high rate diagnosis on late stages of disease. The methods of treatment of peritoneal carcinomatosis, based on possible effects on the secondary peritoneal tumors after surgical cytoreduction to reduce the risk of local recurrence and disease progression are described. These methods of additional intraoperative specific antitumor action include intraoperative radiation therapy, hyperthermic intraperitoneal chemotherapy, intraoperative photodynamic therapy characterized by differences in difficulty of performance, mechanisms of effect on tumor and healthy tissues, efficiency. Benefits, opportunities and possibilities of application of intraoperative photodynamic therapy (IOPDT for secondary peritoneal tumors are described in details, the results of a number of domestic and foreign clinical studies are shown, the successful application of intraoperative photodynamic therapy in clinical oncology, which allows reducing the risk of secondary tumor lesions of the peritoneum significantly, is demonstrated. Photodynamic therapy – a method with high efficiency and almost no side effects and complications, based on the ability of photosensitizer to accumulate selectively and retain in the high proliferative tissues. The advantages of this type of treatment of patients with peritoneal carcinomatosis are a selective effect on the peritoneal carcinomatosis and on visually detected tumor tissue, high efficiency in patients with malignant tumors of the abdominal cavity and pelvis combined with surgical cytoreduction, minimal effect on normal organs and tissues of the patient, well tolerated procedure.

  18. Intraoperative radiation therapy for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Matsutani, Masao; Tanaka, Yoshiaki; Matsuda, Tadayoshi

    1986-01-01

    Intraoperative radiation therapy (IOR) is quite applicable for radioresistant malignant gliomas, because of precise demarcations of the treatment volume under direct vision, minimum damage to surrounding normal tissues, and a high target absorbed dose of 1500 to 2000 rad. Fifteen patients with glioblatoma were treated with IOR, and the 2-year survival rate was 61.1 %. The result apparently indicate that areas adjacent to the margin of almost complete removal should be irradated with a sufficient dose to sterilize the remaining malignant remnants, and IOR is one of the logical treatment modalities for local control of malignant gliomas. (author)

  19. INTRAOPERATIVE PHOTODYNAMIC THERAPY FOR PERITONEAL MESOTHELIOMA

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2017-01-01

    Full Text Available Abstract Results of application of a new technology of intraoperative photodynamic therapy (IOFDT in patients with peritoneal mesothelioma developed at P. Herzen Moscow Oncology Research Institute are presented. The study included 8 patients. 3 patients underwent surgery in various amount: 1 – limited peritonectomy in the volume of tumor foci resection and resection of a large omentum, 1 – limited peritonectomy in the volume of tumor foci resection and atypical resection of the right lobe of the liver, 1 – only resection of the large omentum due to the fact that the tumor was located only in a large omentum and no signs of lesions of the parietal peritoneum was revealed by intraoperative revision. Surgical intervention in these patients was concluded by IOPDT. The remaining 5 patients underwent only IOPDT. After the treatment, two patients underwent additional courses of laparoscopic IOPDT. Of the 8 patients enrolled in the study, 4 died from the underlying disease, 1 from cardiovascular disease with recurrence of the disease, 1 from cardiovascular disease without signs of recurrence, 2 were monitored for 6 months and 146 months (12 years. Thus, in the group of patients with peritoneal mesothelioma, the maximum observation period was 146.44 months, the median survival was 48.4 months, the total specific 1-year survival was 85.7±13.2%, the three-year survival was 68.5±18.6%, the 5-year survival was 45.7 ± 22.4 %. The average life expectancy after treatment of patients with repeated courses of laparoscopic IOPDT was 87 months, without repeated courses – 35.8 months. Thus, life expectancy was higher in patients with repeated courses of laparoscopic IOPDT. Small sample size caused to the rarity of this pathology does not allow for statistically significant conclusions. However, the results of the study indicate the prospects of multi-course intraoperative photodynamic therapy in patients with peritoneal mesothelioma.

  20. Prognostic Value of External Beam Radiation Therapy in Patients Treated With Surgical Resection and Intraoperative Electron Beam Radiation Therapy for Locally Recurrent Soft Tissue Sarcoma: A Multicentric Long-Term Outcome Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, Felipe A. [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Sole, Claudio V., E-mail: cvsole@uc.cl [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); Cambeiro, Mauricio [Service of Radiation Oncology, Clínica Universitaria, Universidad de Navarra, Pamplona (Spain); Montero, Angel; Polo, Alfredo [Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Universidad de Alcala, Madrid (Spain); Gonzalez, Carmen [School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); Service of Radiation Oncology, Clínica Universitaria, Universidad de Navarra, Pamplona (Spain); Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Universidad de Alcala, Madrid (Spain); Service of Radiation Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Cuervo, Miguel [Service of Orthopedics and Traumatology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); San Julian, Mikel [Service of Orthopedics and Traumatology, Clínica Universitaria, Universidad de Navarra, Pamplona (Spain); and others

    2014-01-01

    Background: A joint analysis of data from centers involved in the Spanish Cooperative Initiative for Intraoperative Electron Radiotherapy was performed to investigate long-term outcomes of locally recurrent soft tissue sarcoma (LR-STS) patients treated with a multidisciplinary approach. Methods and Materials: Patients with a histologic diagnosis of LR-STS (extremity, 43%; trunk wall, 24%; retroperitoneum, 33%) and no distant metastases who underwent radical surgery and intraoperative electron radiation therapy (IOERT; median dose, 12.5 Gy) were considered eligible for participation in this study. In addition, 62% received external beam radiation therapy (EBRT; median dose, 50 Gy). Results: From 1986 to 2012, a total of 103 patients from 3 Spanish expert IOERT institutions were analyzed. With a median follow-up of 57 months (range, 2-311 months), 5-year local control (LC) was 60%. The 5-year IORT in-field control, disease-free survival (DFS), and overall survival were 73%, 43%, and 52%, respectively. In the multivariate analysis, no EBRT to treat the LR-STS (P=.02) and microscopically involved margin resection status (P=.04) retained significance in relation to LC. With regard to IORT in-field control, only not delivering EBRT to the LR-STS retained significance in the multivariate analysis (P=.03). Conclusion: This joint analysis revealed that surgical margin and EBRT affect LC but that, given the high risk of distant metastases, DFS remains modest. Intensified local treatment needs to be further tested in the context of more efficient concurrent, neoadjuvant, and adjuvant systemic therapy.

  1. Prognostic Value of External Beam Radiation Therapy in Patients Treated With Surgical Resection and Intraoperative Electron Beam Radiation Therapy for Locally Recurrent Soft Tissue Sarcoma: A Multicentric Long-Term Outcome Analysis

    International Nuclear Information System (INIS)

    Calvo, Felipe A.; Sole, Claudio V.; Cambeiro, Mauricio; Montero, Angel; Polo, Alfredo; Gonzalez, Carmen; Cuervo, Miguel; San Julian, Mikel

    2014-01-01

    Background: A joint analysis of data from centers involved in the Spanish Cooperative Initiative for Intraoperative Electron Radiotherapy was performed to investigate long-term outcomes of locally recurrent soft tissue sarcoma (LR-STS) patients treated with a multidisciplinary approach. Methods and Materials: Patients with a histologic diagnosis of LR-STS (extremity, 43%; trunk wall, 24%; retroperitoneum, 33%) and no distant metastases who underwent radical surgery and intraoperative electron radiation therapy (IOERT; median dose, 12.5 Gy) were considered eligible for participation in this study. In addition, 62% received external beam radiation therapy (EBRT; median dose, 50 Gy). Results: From 1986 to 2012, a total of 103 patients from 3 Spanish expert IOERT institutions were analyzed. With a median follow-up of 57 months (range, 2-311 months), 5-year local control (LC) was 60%. The 5-year IORT in-field control, disease-free survival (DFS), and overall survival were 73%, 43%, and 52%, respectively. In the multivariate analysis, no EBRT to treat the LR-STS (P=.02) and microscopically involved margin resection status (P=.04) retained significance in relation to LC. With regard to IORT in-field control, only not delivering EBRT to the LR-STS retained significance in the multivariate analysis (P=.03). Conclusion: This joint analysis revealed that surgical margin and EBRT affect LC but that, given the high risk of distant metastases, DFS remains modest. Intensified local treatment needs to be further tested in the context of more efficient concurrent, neoadjuvant, and adjuvant systemic therapy

  2. Intraoperative radiation therapy for malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Noboru; Yamada, Hiromu; Andoh, Takashi; Hirata, Toshifumi; Nishimura, Yasuaki; Miwa, Yoshiaki; Shimizu, Kotoyuki; Yanagawa, Shigeo [Gifu Univ. (Japan). Faculty of Medicine

    1991-11-01

    Intraoperative radiation therapy (IORT) was used as part of the initial therapy for malignant glioma in 32 of 73 patients with histologically verified anaplastic astrocytoma (grade III astrocytoma) and glioblastoma multiforme. The initial treatment for all cases was subtotal or total tumor resection combined with external irradiation and chemotherapy. IORT was performed 1 week after tumor resection, with doses of 10-50 Gy (mean 26.7 Gy) in one session. Fourteen of 32 cases had IORT two times because of tumor recurrence. The IORT patients had survival rates at 24 and 36 months after initial treatment of 57.1 and 33.5% (median survival 26.2 months). The other 41 patients had 23.6 and 13.1% survivals (median survival 20.7 months), which were significantly lower (p<0.01). Tumor recurrence within the original lesion site was suspected because of clinical condition, computed tomography, and magnetic resonance imaging studies in 65.6% of the IORT group (21 cases) 12 months after initial treatment. Twenty cases of death in the IORT group, including five autopsy cases, demonstrated regional tumor recurrence with a high incidence of intraventricular tumor invasion. The authors consider IORT is beneficial for selected malignant glioma patients, including tumor recurrence, because of prolonged survival. (author).

  3. Intraoperative radiation therapy for malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Noboru; Yamada, Hiromu; Andoh, Takashi; Takada, Mitsuaki; Hirata, Toshifumi; Funakoshi, Takashi; Doi, Hidetaka; Yanagawa, Shigeo [Gifu Univ. (Japan). Faculty of Medicine

    1989-04-01

    Intraoperative radiation therapy (IOR) is an ideal means of exterminating residual tumor after surgical resection. In this study, the clinical results of IOR using a Scanditronix Microtron MM-22 were evaluated in 14 patients with malignant glioma, five of whom had recurrent tumors. Between July, 1985 and October, 1986, 11 patients with glioblastoma multiforme (GB) were irradiated 18 times (mean, 1.6 times/case), and three with astrocytoma (Kernohan grade III) underwent IOR once each. The target-absorbed dose at 1 to 2 cm deeper than the tumor resection surface was 15 to 50 Gy. During irradiation, a cotton bolus was placed in the dead space after over 91% of the tumor had been resected. As a rule, external irradiation therapy was also given postoperatively at a dose of 30 to 52 Gy. One patient died of pneumonia and disseminated intravascular coagulation syndrome 1 month postoperatively. The 1- and 2-year survival rates of the ramaining 13 patients were 84.6% and 61.5%, respectively; among the 10 with GB, they were 80% and 50%. Generally, the smaller the tumor size, the better the results. There were no adverse effects, despite the dose 15 to 50 Gy applied temporally to the tumor bed. IOR was especially effective against small, localized tumors, but was not always beneficial in cases of large tumors, particularly those with a contralateral focus. The improved survival rate in this series demonstrates that IOR is significantly effective in the 'induction of remission' following surgical excision of malignant gliomas. (author).

  4. Failure mode and effect analysis oriented to risk-reduction interventions in intraoperative electron radiation therapy: The specific impact of patient transportation, automation, and treatment planning availability

    International Nuclear Information System (INIS)

    López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Santos-Serra, Agustín; Morillo-Macías, Virginia; Calvo, Felipe A.; Kubyshin, Yuri

    2014-01-01

    Background and purpose: Industrial companies use failure mode and effect analysis (FMEA) to improve quality. Our objective was to describe an FMEA and subsequent interventions for an automated intraoperative electron radiotherapy (IOERT) procedure with computed tomography simulation, pre-planning, and a fixed conventional linear accelerator. Material and methods: A process map, an FMEA, and a fault tree analysis are reported. The equipment considered was the radiance treatment planning system (TPS), the Elekta Precise linac, and TN-502RDM-H metal–oxide-semiconductor-field-effect transistor in vivo dosimeters. Computerized order-entry and treatment-automation were also analyzed. Results: Fifty-seven potential modes and effects were identified and classified into ‘treatment cancellation’ and ‘delivering an unintended dose’. They were graded from ‘inconvenience’ or ‘suboptimal treatment’ to ‘total cancellation’ or ‘potentially wrong’ or ‘very wrong administered dose’, although these latter effects were never experienced. Risk priority numbers (RPNs) ranged from 3 to 324 and totaled 4804. After interventions such as double checking, interlocking, automation, and structural changes the final total RPN was reduced to 1320. Conclusions: FMEA is crucial for prioritizing risk-reduction interventions. In a semi-surgical procedure like IOERT double checking has the potential to reduce risk and improve quality. Interlocks and automation should also be implemented to increase the safety of the procedure

  5. Failure mode and effect analysis oriented to risk-reduction interventions in intraoperative electron radiation therapy: the specific impact of patient transportation, automation, and treatment planning availability.

    Science.gov (United States)

    López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Santos-Serra, Agustín; Morillo-Macías, Virginia; Calvo, Felipe A; Kubyshin, Yuri; Ferrer-Albiach, Carlos

    2014-11-01

    Industrial companies use failure mode and effect analysis (FMEA) to improve quality. Our objective was to describe an FMEA and subsequent interventions for an automated intraoperative electron radiotherapy (IOERT) procedure with computed tomography simulation, pre-planning, and a fixed conventional linear accelerator. A process map, an FMEA, and a fault tree analysis are reported. The equipment considered was the radiance treatment planning system (TPS), the Elekta Precise linac, and TN-502RDM-H metal-oxide-semiconductor-field-effect transistor in vivo dosimeters. Computerized order-entry and treatment-automation were also analyzed. Fifty-seven potential modes and effects were identified and classified into 'treatment cancellation' and 'delivering an unintended dose'. They were graded from 'inconvenience' or 'suboptimal treatment' to 'total cancellation' or 'potentially wrong' or 'very wrong administered dose', although these latter effects were never experienced. Risk priority numbers (RPNs) ranged from 3 to 324 and totaled 4804. After interventions such as double checking, interlocking, automation, and structural changes the final total RPN was reduced to 1320. FMEA is crucial for prioritizing risk-reduction interventions. In a semi-surgical procedure like IOERT double checking has the potential to reduce risk and improve quality. Interlocks and automation should also be implemented to increase the safety of the procedure. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy.

    Science.gov (United States)

    Sarmento, Sandra; Costa, Filipa; Pereira, Alexandre; Lencart, Joana; Dias, Anabela; Cunha, Luís; Sousa, Olga; Silva, José Pedro; Santos, Lúcio

    2015-01-09

    Surgery of locally advanced and/or recurrent rectal cancer can be complemented with intra-operative electron radiation therapy (IOERT) to deliver a single dose of radiation directly to the unresectable margins, while sparing nearby sensitive organs/structures. Haemorrhages may occur and can affect the dose distribution, leading to an incorrect target irradiation. The TachoSil (TS) surgical patch, when activated, creates a fibrin clot at the surgical site to achieve haemostasis. The aim of this work was to determine the effect of TS on the dose distribution, and ascertain whether it could be used in combination with IOERT. This characterization was extended to include high dose rate (HDR) intraoperative brachytherapy, which is sometimes used at other institutions instead of IOERT. CT images of the TS patch were acquired for initial characterization. Dosimetric measurements were performed in a water tank phantom, using a conventional LINAC with a hard-docking system of cylindrical applicators. Percentage Depth Dose (PDD) curves were obtained, and measurements made at the depth of dose maximum for the three clinically used electron energies (6, 9 and 12MeV), first without any attenuator and then with the activated patch of TS completely covering the tip of the IOERT applicator. For HDR brachytherapy, a measurement setup was improvised using a solid water phantom and a Farmer ionization chamber. Our measurements show that the attenuation of a TachoSil patch is negligible, both for high energy electron beams (6 to 12MeV), and for a HDR (192)Ir brachytherapy source. Our results cannot be extrapolated to lower beam energies such as 50 kVp X-rays, which are sometimes used for breast IORT. The TachoSil surgical patch can be used in IORT procedures using 6MeV electron energies or higher, or HDR (192)Ir brachytherapy.

  7. Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Sarmento, Sandra; Costa, Filipa; Pereira, Alexandre; Lencart, Joana; Dias, Anabela; Cunha, Luís; Sousa, Olga; Silva, José Pedro; Santos, Lúcio

    2015-01-01

    Surgery of locally advanced and/or recurrent rectal cancer can be complemented with intra-operative electron radiation therapy (IOERT) to deliver a single dose of radiation directly to the unresectable margins, while sparing nearby sensitive organs/structures. Haemorrhages may occur and can affect the dose distribution, leading to an incorrect target irradiation. The TachoSil (TS) surgical patch, when activated, creates a fibrin clot at the surgical site to achieve haemostasis. The aim of this work was to determine the effect of TS on the dose distribution, and ascertain whether it could be used in combination with IOERT. This characterization was extended to include high dose rate (HDR) intraoperative brachytherapy, which is sometimes used at other institutions instead of IOERT. CT images of the TS patch were acquired for initial characterization. Dosimetric measurements were performed in a water tank phantom, using a conventional LINAC with a hard-docking system of cylindrical applicators. Percentage Depth Dose (PDD) curves were obtained, and measurements made at the depth of dose maximum for the three clinically used electron energies (6, 9 and 12MeV), first without any attenuator and then with the activated patch of TS completely covering the tip of the IOERT applicator. For HDR brachytherapy, a measurement setup was improvised using a solid water phantom and a Farmer ionization chamber. Our measurements show that the attenuation of a TachoSil patch is negligible, both for high energy electron beams (6 to 12MeV), and for a HDR 192 Ir brachytherapy source. Our results cannot be extrapolated to lower beam energies such as 50 kVp X-rays, which are sometimes used for breast IORT. The TachoSil surgical patch can be used in IORT procedures using 6MeV electron energies or higher, or HDR 192 Ir brachytherapy

  8. Intraoperative radiation therapy (IORT) for adenocarcinoma of the pancreas

    International Nuclear Information System (INIS)

    Yasue, Mitsunori

    1988-01-01

    Between April 1980 and August 1987, a total of 54 patients with pancreatic adenocarcinoma were treated with intraoperative radiation therapy (IORT). Thirty-five patients underwent IORT with palliative intent (Group I), and the remaining 19 underwent it as an adjuvant therapy for pancreatectomy (Group II). The dosage of electron beams ranged from 12 to 30 Gy in Group I and from 20 to 30 Gy in Group II. Intractable back pain that was observed in 25 patients was relieved in 20 patients (80 %) within one week after IORT. The median survival was 5.3 months in Group I and 9.4 months in Group II. The longest survival (6 years and 10 months) was attained in a patient undergoing absolute non-curative distal pancreatectomy, followed by 20 Gy of IORT. In comparing patients treated before and after the introduction of IORT, both survival rate and staying-home survival rate were significantly better in the era of IORT during which background factors were rather worse. (Namekawa, K.)

  9. Intraoperative radiation therapy (IORT) for adenocarcinoma of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Yasue, Mitsunori

    1988-04-01

    Between April 1980 and August 1987, a total of 54 patients with pancreatic adenocarcinoma were treated with intraoperative radiation therapy (IORT). Thirty-five patients underwent IORT with palliative intent (Group I), and the remaining 19 underwent it as an adjuvant therapy for pancreatectomy (Group II). The dosage of electron beams ranged from 12 to 30 Gy in Group I and from 20 to 30 Gy in Group II. Intractable back pain that was observed in 25 patients was relieved in 20 patients (80 %) within one week after IORT. The median survival was 5.3 months in Group I and 9.4 months in Group II. The longest survival (6 years and 10 months) was attained in a patient undergoing absolute non-curative distal pancreatectomy, followed by 20 Gy of IORT. In comparing patients treated before and after the introduction of IORT, both survival rate and staying-home survival rate were significantly better in the era of IORT during which background factors were rather worse. (Namekawa, K.).

  10. Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Sole, Claudio V., E-mail: cvsole@uc.cl [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); Calvo, Felipe A. [Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); School of Medicine, Complutense University, Madrid (Spain); Polo, Alfredo [Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Madrid (Spain); Cambeiro, Mauricio [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain); Alvarez, Ana; Gonzalez, Carmen [Service of Radiation Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Gonzalez, Jose [Service of Pediatric Orthopedics and Traumatology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); San Julian, Mikel [Service of Orthopedics and Traumatology, Clínica Universidad de Navarra, Pamplona (Spain); Martinez-Monge, Rafael [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain)

    2014-09-01

    Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results.

  11. Anticipated Intraoperative Electron Beam Boost, External Beam Radiation Therapy, and Limb-Sparing Surgical Resection for Patients with Pediatric Soft-Tissue Sarcomas of the Extremity: A Multicentric Pooled Analysis of Long-Term Outcomes

    International Nuclear Information System (INIS)

    Sole, Claudio V.; Calvo, Felipe A.; Polo, Alfredo; Cambeiro, Mauricio; Alvarez, Ana; Gonzalez, Carmen; Gonzalez, Jose; San Julian, Mikel; Martinez-Monge, Rafael

    2014-01-01

    Purpose: To perform a joint analysis of data from 3 contributing centers within the intraoperative electron-beam radiation therapy (IOERT)-Spanish program, to determine the potential of IOERT as an anticipated boost before external beam radiation therapy in the multidisciplinary treatment of pediatric extremity soft-tissue sarcomas. Methods and Materials: From June 1993 to May 2013, 62 patients (aged <21 years) with a histologic diagnosis of primary extremity soft-tissue sarcoma with absence of distant metastases, undergoing limb-sparing grossly resected surgery, external beam radiation therapy (median dose 40 Gy) and IOERT (median dose 10 Gy) were considered eligible for this analysis. Results: After a median follow-up of 66 months (range, 4-235 months), 10-year local control, disease-free survival, and overall survival was 85%, 76%, and 81%, respectively. In multivariate analysis after adjustment for other covariates, tumor size >5 cm (P=.04) and R1 margin status (P=.04) remained significantly associated with local relapse. In regard to overall survival only margin status (P=.04) retained association on multivariate analysis. Ten patients (16%) reported severe chronic toxicity events (all grade 3). Conclusions: An anticipated IOERT boost allowed for external beam radiation therapy dose reduction, with high local control and acceptably low toxicity rates. The combined radiosurgical approach needs to be tested in a prospective trial to confirm these results

  12. Debate: Pro intraoperative radiation therapy in breast cancer; Debat: pour la radiotherapie peroperatoire dans le cancer du sein

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J.B.; Lemanski, C.; Azria, D. [Departement de radiotherapie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France); Gutowski, M.; Rouanet, P.; Saint-Aubert, B. [Departement de chirurgie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France)

    2011-10-15

    The use of intraoperative radiation therapy in breast cancer patients started about 20 years ago. Several retrospective and prospective studies have been published. Intraoperative radiation therapy was initially given as a boost to the tumour bed, followed by whole-breast irradiation. These studies have demonstrated the feasibility of the technique, with local control rates and cosmetic results similar to those obtained with standard treatments. Accelerated partial breast irradiation yields local recurrence rates as low as those observed after whole-breast irradiation. Intraoperative radiation therapy as a single irradiation modality with a unique dose has been investigated in recent prospective studies showing satisfactory local results. Intraoperative radiation therapy can be proposed either as a boost or as a unique treatment in selected cases (tumour size, nodal and hormonal status, patient's age). Intraoperative radiation therapy can be delivered by orthovoltage (50 kV) X-rays from mobile generators, or by electrons from linear accelerators, mobile or fixed, dedicated or not to intraoperative radiation therapy. (authors)

  13. Intraoperative radiation therapy for locally advanced gynecological malignancies

    International Nuclear Information System (INIS)

    Haddock, M.G.; Petersen, I.A.; Webb, M.J.; Wilson, T.O.; Podratz, K.C.; Gunderson, L.L.

    1996-01-01

    Purpose: Evaluate disease control and survival in patients with locally advanced gynecological malignancies who received intraoperative radiation therapy with electrons (IOERT) as a component of treatment. Methods and Materials: Between March 1983 and June 1995, 63 patients (pts) with locally advanced primary (9 pts) or recurrent (54 pts) gynecological malignancies received IOERT as a component of attempted curative therapy. The site of origin was uterine cervix in 40 pts, uterine corpus in 16 pts, vagina in 5 pts, and ovary in 2 pts. Thirty-eight patients with recurrent disease had been previously irradiated (median prior RT dose 5040 cGy, range 900-8400). External beam radiotherapy (EBRT) was given to 43 of 63 pts either before or after IOERT (900-6570 cGy, median 4960 cGy). Chemotherapy was given to 21 pts prior to IOERT and following IOERT in 2 pts. IOERT doses ranged from 800 cGy to 2500 cGy with a median of 1750 cGy. The median IOERT dose was 2000 cGy in 20 patients with gross residual disease and 1500 cGy in 43 patients with microscopic residual disease. Endpoints included central control within the IOERT cone, local control, distant failure, disease free survival and overall survival. Variables evaluated for impact on disease outcome included tumor grade, primary site, prior RT, IOERT dose, EBRT dose, residual disease at time of IOERT, and use of chemotherapy. Results: Survival and disease control data are presented in the table below. There was no impact of any disease or treatment related variable on local or central failure. Pts with microscopic residual disease at the time of IOERT had significantly fewer distant metastases than pts with gross residual (5 yr 31% vs. 77%, p = 0.001) and improved survival (5 yr 37% vs. 10%, p = 0.02). Patients with recurrent disease after previous RT had survival and disease control rates which were similar to those seen in pts without priot RT. Toxicity ≥ grade 3 due to IOERT was observed in 11 pts (17%). Conclusion: A

  14. Intraoperative radiation therapy in gynecologic cancer: update of the experience at a single institution

    International Nuclear Information System (INIS)

    Garton, Graciela R.; Gunderson, Leonard L.; Webb, Maurice J.; Wilson, Timothy O.; Cha, Stephen S.; Podratz, Karl C.

    1997-01-01

    Purpose: To update the Mayo Clinic experience with intraoperative radiation therapy (IORT) in patients with gynecologic cancer. Methods and Materials: Between January 1983 and June 1991, 39 patients with recurrent or locally advanced gynecologic malignancies received intraoperative radiation therapy with electrons. The anatomical area treated was pelvis (side walls or presacrum) or periaortic nodes or a combination of both. In addition to intraoperative radiation therapy, 28 patients received external beam irradiation (median dose, 45 Gy; range, 0.9 to 65.7 Gy), and 13 received chemotherapy preoperatively. At the time of intraoperative radiation therapy and after maximum debulking operation, 23 patients had microscopic residual disease and 16 had gross residual disease up to 5 cm in thickness. Median follow-up for surviving patients was 43.4 months (range, 27.1 to 125.4 months). Results: The 5-year actuarial local control with or without central control was 67.4%, and the control within the IORT field (central control) was 81%. The risk of distant metastases at 5 years was 52% (82% in patients with gross residual disease and 33% in patients with only microscopic disease postoperatively). Actuarial 5-year overall survival and disease-free survival was 31.5 and 40.5%, respectively. Patients with microscopic disease had 5-year disease-free and overall survival of 55 and 50%, respectively. Grade 3 toxicity was directly associated with IORT in six patients (15%). Conclusion: Patients with local, regionally recurrent gynecologic cancer may benefit from maximal surgical debulking and IORT with or without external beam irradiation, especially those with microscopic residual disease

  15. Intraoperative radio-frequency capacitive hyperthermia and radiation therapy for unresectable pancreatic cancer

    International Nuclear Information System (INIS)

    Nakazawa, M.; Yamashita, T.; Hashida, I.

    1988-01-01

    The authors have initiated intraoperative radiation therapy (IORT) and intraoperative radio-frequency capacitive hyperthermia (IOHT) for unresectable pancreatic cancer. After gastric (corpus) resection, IORT and IOHT were conducted and gastro-duodenostomy was performed IORT was delivered with 12 meV electron (25 Gy) and 10 MV Linac x-ray (7.5 Gy). IOHT was done with 13.56 MHz capacitive equipment aiming 43 0 C for over 30 min along with concurrent administration of 500 mg 5-FU. Five cases were heated by the conventional method and two additional cases were heated with a newly fabricated applicator. Attained temperatures monitored directly from tumor were 38.5 0 C-44.3 0 C (over 43 0 C in four cases, 40 0 C in one case, and below 40 0 C in two cass.) Pain relief was achieved in most cases. Using the new applicators, the authors could avoid unexpected hot spots and insufficient heating

  16. Tolerance of canine anastomoses to intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Tepper, J.E.; Sindelar, W.; Travis, E.L.; Terrill, R.; Padikal, T.

    1983-01-01

    Radiation has been given intraoperatively to various abdominal structures in dogs, using a fixed horizontal 11 MeV electron beam at the Armed Forces Radiobiologic Research Institute. Animals were irradiated with single doses of 2000, 3000 and 4500 rad to a field which extended from the bifurcation of the aorta to the rib cage. All animals were irradiated during laparotomy under general anesthesia. Because the clinical use of intraoperative radiotherapy in cancer treatment will occasionally require irradiation of anastomosed large vessels and blind loops of bowel, the tolerance of aortic anastomoses and the suture lines of blind loops of jejunum to irradiation were studied. Responses in these experiments were scored at times up to one year after irradiation. In separate experiments both aortic and intestinal anastomoses were performed on each animal for evaluation of short term response. The dogs with aortic anastomoses showed adequate healing at all doses with no evidence of suture line weakening. On long-term follow-up one animal (2000 rad) had stenosis at the anastomosis and one animal (4500 rad) developed an arteriovenous fistula. Three of the animals that had an intestinal blind loop irradiated subsequently developed intussusception, with the irradiated loop acting as the lead point. One week after irradiation, bursting pressure of an intestinal blind loop was normal at 3000 rad, but markedly decreased at 4500 rad. No late complications were noted after the irradiation of the intestinal anastomosis. No late complicatons were observed after irradiation of intestinal anastomoses, but one needs to be cautious with regards to possible late stenosis at the site of an irradiated vascular anastomosis

  17. Limb-sparing management with surgical resection, external-beam and intraoperative electron-beam radiation therapy boost for patients with primary soft tissue sarcoma of the extremity. A multicentric pooled analysis of long-term outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, Felipe A. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Sole, Claudio V. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Instituto de Radiomedicina, Service of Radiation Oncology, Santiago (Chile); Polo, Alfredo; Montero, Angel [Hospital Universitario Ramon y Cajal, Service of Radiation Oncology, Madrid (Spain); Cambeiro, Mauricio; Martinez-Monge, Rafael [Clinica Universidad de Navarra, Service of Radiation Oncology, Pamplona (Spain); Alvarez, Ana [Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Cuervo, Miguel [Hospital General Universitario Gregorio Maranon, Service of Orthopedics and Traumatology, Madrid (Spain); Julian, Mikel San [Clinica Universidad de Navarra, Service of Orthopedics and Traumatology, Pamplona (Spain)

    2014-10-15

    A joint analysis of data from three contributing centres within the intraoperative electron-beam radiation therapy (IOERT) Spanish program was performed to investigate the main contributions of IORT to the multidisciplinary treatment of high-risk extremity soft tissue sarcoma (STS). Patients with an histologic diagnosis of primary extremity STS, with absence of distant metastases, undergoing limb-sparing surgery with radical intent, external beam radiotherapy (median dose 45 Gy) and IOERT (median dose 12.5 Gy) were considered eligible for participation in this study. From 1986-2012, a total of 159 patients were analysed in the study from three Spanish institutions. With a median follow-up time of 53 months (range 4-316 years), 5-year local control (LC) was 82 %. The 5-year IOERT in-field control, disease-free survival (DFS) and overall survival (OS) were 86, 62 and 72 %, respectively. On multivariate analysis, only microscopically involved margin (R1) resection status retained significance in relation to LC (HR 5.20, p < 0.001). With regard to IOERT in-field control, incomplete resection (HR 4.88, p = 0.001) and higher IOERT dose (≥ 12.5 Gy; HR 0.32, p = 0.02) retained a significant association in multivariate analysis. From this joint analysis emerges the fact that an IOERT dose ≥ 12.5 Gy increases the rate of IOERT in-field control, but DFS remains modest, given the high risk of distant metastases. Intensified local treatment needs to be tested in the context of more efficient concurrent, neo- and adjuvant systemic therapy. (orig.) [German] Um den therapeutischen Beitrag einer intraoperativen Bestrahlung mit Elektronen (IOERT) als Teil eines multidisziplinaeren Behandlungskonzepts von Weichteilsarkomen (STS) im Extremitaetenbereich mit hohem Risikoprofil evaluieren zu koennen, wurde anhand des spanischen IOERT-Programms eine gepoolte Datenanalyse von drei teilnehmenden Zentren vorgenommen. Eingeschlossen in diese Studie wurden Patienten mit histologisch

  18. Intra-operative radiation therapy in cancer of the pancreas

    International Nuclear Information System (INIS)

    Dubois, J.B.; Gu, S.D.; Saint-Aubert, B.; Joyeux, H.; Solassol, C.; Pujol, H.

    1991-01-01

    We report our experience concerning 22 pancreatic carcinoma bearing patients treated with intra-operative radiation therapy (IORT) after complete surgical excision: duodenopancreatectomy: 15 patients; isthmic and caudal pancreatectomy: 2 patients; total pancreatectomy: 5 patients. The dose delivered to the tumor bed was 20 Gy in 12 patients, 18 Gy in 3 patients and 15 Gy in 7 patients. Three patients died within the 1st month post-surgery from intercurrent diseases. Post-operative morbidity was not significantly modified by IORT as compared to purely surgical treated patients. Out of 19 evaluable patients, we observed local control in 16 patients (79.4%). Causes of death (15/19 patients) were: distant metastases with local control: 7 patients; in situ local failure: 3 patients; regional recurrence outside of the IORT fields: 2 patients; intercurrent diseases: 3 patients. Four patients are still alive without evolutive disease. The median overall survival is 6 months. The mean overall survival is 10.56 months. Excluding patients who died from complications and intercurrent diseases, the median survival is 10 mths and the mean survival 14.5 mths. These results emphasize the improvement in local control with IORT, but without significant improvement in survival which is dependent on local evolution and also systemic disease [fr

  19. Intraoperative radiation therapy for patients with pancreatic carcinoma

    International Nuclear Information System (INIS)

    Abe, Tetsuo; Itoh, Kei; Agawa, Senichiro; Ishihara, Yukio; Konishi, Toshiro

    2001-01-01

    We studied the efficacy and complications of intraoperative radiation therapy (IORT) in 40 subjects with unresected pancreatic carcinoma (Group A) and 8 with resected pancreatic carcinoma (Group B). These 2 groups were compared to groups not treated by IORT; 59 subjects with unresected pancreatic carcinoma (Group C) and 55 with resected pancreatic carcinoma (Group D). The 6-month survival in Group A was 55%, and 1-year survival 26% compared to 20% 6-month survival and 9% 1-year survival in Group C with a median survival of 7 months in Group A and 4 months in group C; all statistically significant. Pain control was 81.8% in Group A, reduction in tumor size was 50% and reduction of tumor marker, CA19-9 was 56.3% in Group A. Survival in Groups B and D did not differ significantly. The histological efficacy of IORT in Group A was confirmed in autopsy of fibrosis and scar formation in radiation fields of the pancreas. Two patients in Group B had major morbidity leading to death; 1 from leakage in the pancreatojejunal anastomosis accompanied by pancreatic necrosis and the other from duodenal perforation with rupture of the portal vein and hepatic artery. This study demonstrates the efficacy of IORT in patients with unresected pancreatic carcinoma. Prophylactic bypass and shielding of the residual pancreas with lead or reducing the IORT or external beam radiation therapy (EBRT) dose should be considered in patients with unresected or resected pancreatic carcinoma, however, to prevent serious complications due to radiation injury of the duodenum and pancreas. (author)

  20. Response of canine esophagus to intraoperative electron beam radiotherapy

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Hoekstra, H.J.; Kinsella, T.J.; Barnes, M.; DeLuca, A.M.; Tochner, Z.; Pass, H.I.; Kranda, K.C.; Terrill, R.E.

    1988-01-01

    Tolerance of esophagus to intraoperative radiotherapy (IORT) was investigated in dogs. Thirteen adult foxhounds were subjected to right thoractomy, mobilization of the intrathoracic esophagus, and IORT to a 6 cm full-thickness esophageal segment using 9 MeV electrons at doses of 0, 2,000, or 3,000 cGy. Dogs were followed clinically and were evaluated at regular intervals after treatment with fiberoptic esophagoscopy, barium swallows, and postmortem histologic evaluations. One sham-irradiated control dog showed no abnormalities during follow-up of 24 months. Seven dogs receiving 2,000 cGy IORT showed transient mild dysphagia and mild esophagitis, but no clinically or pathologically significant complications. Five dogs receiving 3,000 cGy demonstrated severe ulcerative esophagitis within 6 weeks of treatment which progressed to chronic ulcerative esophagitis with stricture formation by 9 months following IORT. One 3,000 cGy dog died at 13 months from an esophageal perforation. On the basis of a pilot experience using 13 experimental animals, it was concluded that intact canine esophagus tolerates IORT well to doses of 2,000 cGy, but doses of 3,000 cGy pose serious and potentially lethal risks. The clinical application of IORT to the treatment of human intrathoracic neoplasms requiring esophageal irradiation should be approached with caution, particularly at doses exceeding 2,000 cGy

  1. Intraoperative radiation therapy for carcinoma of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Masashi; Takashima, Shigemitsu (Shikoku Cancer Center Hospital, Ehime (Japan)); Kataoka, Masaaki (and others)

    1991-12-01

    From May 1978 through December 1989, 54 patients with pancreatic carcinoma underwent electron beam intraoperative radiotherapy (IORT). Three died of perioperative complications within a month. Nineteen patients who had liver metastasis and/or peritoneal dissemination were treated with IORT with palliative intent. Of 14 patients having pain, 12 (85.7%) had pain relief, including 3 who were treated in combination with splanchnic nerve block. The remaining 32 patients were treated with curative intent for localized carcinoma (total tumor resection in 6, partial resection in 6, and no tumor resection in 20). When comparing these IORT-treated patients with the other 40 patients without IORT (total tumor resection in 13, partial resection in 9, and no tumor resection in 18), the survival was significantly longer in the IORT-treated group (p<0.05 during the 18th month) than the non-treated group. Twenty patients without tumor resection in the IORT-treated group survived significantly longer than the corresponding 18 patients in the non-treated group (p<0.05 during the 7th month). For 26 patients receiving IORT with partial tumor resection or without tumor resection, either additional external irradiation or IORT using a small field within a large field improved survival time significantly, as compared with IORT using a single field (p<0.05 during the 7th and 8th month). Of 19 patients having pain in the IORT treated group without tumor resection, pain relief was achieved in 18 patients (94.7%), including 2 who also had combination of splanchnic nerve block. For evaluable 26 patients surviving 6 months or longer, the most common adverse effect was gastrointestinal problems, such as gastric ulcer, duodenal stenosis, and duodenal perforation. In conclusion, IORT may contribute to pain relief and longer survival time for localized pancreatic carcinoma. (N.K.).

  2. Intraoperative Electron Radiotherapy for the Management of Aggressive Fibromatosis

    International Nuclear Information System (INIS)

    Roeder, Falk; Timke, Carmen; Oertel, Susanne; Hensley, Frank W.; Bischof, Marc; Muenter, Marc W.; Weitz, Juergen; Buchler, Markus W.; Lehner, Burkhard; Debus, Juergen; Krempien, Robert

    2010-01-01

    Purpose: We analyzed our experience with intraoperative electron radiotherapy (IOERT) followed by moderate doses of external beam radiotherapy (EBRT) after organ-sparing surgery in patients with primary or recurrent aggressive fibromatosis. Methods and Materials: Indication for IOERT and postoperative EBRT as an individual treatment approach to avoid mutilating surgical procedures was seen when complete surgical removal seemed to be unlikely or impossible. A total of 31 lesions in 30 patients were treated by surgery and IOERT with a median dose of 12 Gy. Median age was 31 years (range, 13-59 years). Resection status was close margin in six lesions, microscopically positive in 13, and macroscopically positive in 12. Median tumor size was 9 cm. In all, 25 patients received additional EBRT, with a median dose of 45 Gy (range, 36-54 Gy). Results: After a median follow-up of 32 months (range, 3-139 months), no disease-related deaths occurred. A total of five local recurrences were seen, resulting in actuarial 3-year local control rates of 82% overall and 91% inside the IOERT areas. Trends to improved local control were seen for older age (>31 years) and negative margins, but none of these factors reached significance. Perioperative complications were found in six patients, in particular as wound healing disturbances in five patients and venous thrombosis in one patient. Late toxicity was seen in five patients. Conclusion: Introduction of IOERT into a multimodal treatment approach in patients with aggressive fibromatosis is feasible with low toxicity and yielded good local control rates even in patients with microscopical or gross residual disease.

  3. Peripheral nerve and ureteralo tolerance to intraoperative radiation therapy; Clinical and dose-response analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, E.G.; Gunderson, L.L.; Martin, J.K.; Baers, R.W.; Nagorney, D.M.; Podratz, K.C. (Mayo Clinic, Rochester, MN (USA))

    1990-07-01

    Between April 1981 and July 1984, 51 received intraoperative radiation therapy (IORT) as a component of therapy for the management of primary of recurrent pelvic malignancies which were initially unresectable for cure. For these patients, curative surgical alternatives did not exist, or would have involved extensive procedures such as pelvic exenteration, distal sacrectomy, hemipelvectomy, or hemicorporectemy. The primary disease was colorectal in 38 patients. Treatment consisted of external beam radiation (range 3000 to 6890 cGy, median 5040 cGy), surgical debulking when feasible, and an intraoperative electron beam boost to the gross of microscopic residual desease (dose range 1000 to 2500 cGy, median 1750 cGy) utilizing 9-18 MeV electrons. The most common IORT associated toxicities were peripheral neurophaty and ureteral obstruction. None were life-threatening or fatal in severity. Of the 50 patients evaluable for neurotoxicity analysis, 16 (32%) developed peripheral neurophaty consisting of pain in 16 patients, numbness and tingling in 11, and weakness in 8. The pain, numbness and tingling resolved in about 40% of patients, while weakness resolved in only 1 of 8. Sixteen ureters were initially unobstructed by tumor at the time of IORT. Of these, 10 (63%) subsequently showed evidence of obstruction and hydronephrosis. The development of neurotoxicity was more common at IORT doses of 1500 cGy or more versus 1000 cGy. Ureteral obstruction with hydronephrosis occurred more frequently at IORT doses of 1250 cGy or more compared to 1000 cGy. There was no relationship between the likelihood of developing complications and the total external beam dose. The observed dependence of human nerve toxicity primarily on the IORT dose is consistent with data generated form animal experiments. (author). 21 refs.; 4 tabs.

  4. Safty and acute toxicities of intraoperative electron radiotherapy for patients with abdominal tumors

    International Nuclear Information System (INIS)

    Zhai Yirui; Feng Qinfu; Li Minghui

    2010-01-01

    Objective: To investigate the safety and acute toxicities of intraoperative electron radiotherapy for patients with abdominal tumors. Methods: From May 2008 to August 2009, 52 patients with abdominal tumors were treated with intraoperative electron radiotherapy, including 14 patients with breast cancer,19 with pancreatic cancer, 3 with cervical cancer, 4 with ovarian cancer, 6 with sarcoma, and 6 with other tumors. Fifteen patients were with recurrent tumors. The intraoperative radiotherapy was performed using Mobetron mobile electron accelerator, with total dose of 9 - 18 Gy. In all, 29, 4 and 19 patients received complete resection, palliative resection and surgical exploration, respectively. The complications during the operations and within 6 months after operations were graded according to Common Terminology Criteria for Adverse Events v3.0 (CTC 3.0). Results: The median duration of surgery was 190 minutes. Intraoperative complications were observed in 5 patients, including 3 with hemorrhage, 1 with hypotension,and 1 with hypoxaemia, all of which were treated conservatively. The median hospitalization time and time to take out stitches was 12 and 13 days, respectively. And the in-hospital mortality was 4% (2/52). Twenty-four patients suffered post-operative adverse events, including 3 postoperative infections. With a median follow-up time of 183 days, 20% of patients suffered from grade 3 to 5 adverse events, with hematological toxicities being the most common complication, followed by bellyache. Grade 1 and 2 toxicities which were definitely associated with intraoperative radiotherapy was 28% and 4%, respectively. None of grade 3 to 5 complications were proved to be caused by intraoperative radiotherapy. Conclusions: Intraoperative electron radiotherapy is well tolerable and could be widely used for patients with abdominal tumors, with a little longer time to take out stitches but without more morbidities and toxicities compared surgery alone. (authors)

  5. Television system for verification and documentation of treatment fields during intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Fraass, B.A.; Harrington, F.S.; Kinsella, T.J.; Sindelar, W.F.

    1983-01-01

    Intraoperative radiation therapy (IORT) involves direct treatment of tumors or tumor beds with large single doses of radiation. The verification of the area to be treated before irradiation and the documentation of the treated area are critical for IORT, just as for other types of radiation therapy. A television system which allows the target area to be directly imaged immediately before irradiation has been developed. Verification and documentation of treatment fields has made the IORT television system indispensable

  6. [Intraoperative lysis and neurostimulation as added therapy in surgery of popliteal artery aneurysm].

    Science.gov (United States)

    Peiper, C; Heye, K; Ktenidis, K; Horsch, S

    1997-01-01

    Additional therapy of symptomatic popliteal artery aneurysm includes intraoperative lysis for the treatment of the descending thrombosis and spinal cord stimulation for cases of chronic deterioration of the peripheral perfusion state. Between 1989 and 1996, we treated 50 patients with 55 symptomatic aneurysms using this concept, 18 of them as emergency cases. We reached a postoperative amputation rate of 12.7% and good long-term functional results in 34 of 37 patients.

  7. Intra-operative mapping of the atria: the first step towards individualization of atrial fibrillation therapy?

    Science.gov (United States)

    Kik, Charles; Mouws, Elisabeth M J P; Bogers, Ad J J C; de Groot, Natasja M S

    2017-07-01

    Atrial fibrillation (AF), an age-related progressive disease, is becoming a worldwide epidemic with a prevalence rate of 33 million. Areas covered: In this expert review, an overview of important results obtained from previous intra-operative mapping studies is provided. In addition, our novel intra-operative high resolution mapping studies, its surgical considerations and data analyses are discussed. Furthermore, the importance of high resolution mapping studies of both sinus rhythm and AF for the development of future AF therapy is underlined by our most recent results. Expert commentary: Progression of AF is determined by the extensiveness of electropathology which is defined as conduction disorders caused by structural damage of atrial tissue. The severity of electropathology is a major determinant of therapy failure. At present, we do not have any diagnostic tool to determine the degree of electropathology in the individual patient and we can thus not select the most optimal treatment modality for the individual patient. An intra-operative, high resolution scale, epicardial mapping approach combined with quantification of electrical parameters may serve as a diagnostic tool to stage AF in the individual patient and to provide patient tailored therapy.

  8. Intraoperative radiation therapy in patients with bladder cancer. A review of techniques allowing improved tumor doses and providing high cure rates without loss of bladder function

    International Nuclear Information System (INIS)

    Shipley, W.U.; Kaufman, S.D.; Prout, G.R. Jr.

    1987-01-01

    Conventional external beam irradiation, using modern megavoltage techniques and doses that do not harm bladder function, will permanently eradicate local bladder cancer in 30% to 50% of patients, compared with 70% to 90% with cystectomy. In appropriately chosen patients, open surgery can safely provide excellent exposure for the selective delivery of more radiant energy directly to the tumor and less to the uninvolved portion of the bladder. Intraoperative radiation therapy, by either a removable radium or iridium implant or a large single dose of electrons, has been reported to be safe and can permanently cure the bladder of cancer and also preserve bladder function in more than 75% of patients with solitary tumors that invade into but not beyond the bladder muscle. With the increasing interest in and availability of intraoperative radiation therapy in the US, this curative and bladder-sparing treatment for operable patients with bladder cancer invading the trigone is appropriate for careful clinical trial. 13 references

  9. Analysis of enzyme targeting intraoperative radiosensitization therapy (KORTUC-IORT) for abdominal malignant tumors

    International Nuclear Information System (INIS)

    Nishioka, Akihito; Kariya, Shinji; Kataoka, Y.; Miyatake, Kana; Tadokoro, Michiko; Hamada, Norihiko; Kubota, Kei; Ogawa, Yasuhiro

    2013-01-01

    We developed a new radiosensitizer injection containing hydrogen peroxide and sodium hyaluronate just followed by intraoperative radiotherapy (IORT) for locally advanced pancreatic cancer, named KORTUC-IORT (Kochi Oxydol-Radiation Therapy for Unresectable Carcinomas+IORT). Fourteen patients were treated with KORTUC-IORT, external beam radiotherapy, and systemic chemotherapy. All treatments related with KORTUC-IORT were well tolerated, with few adverse effects. The 1- and 2-year survival rates were 75% and 25%, respectively. The median survival period is 15 months. The present formulation can be delivered safely and effectively under the conditions used. (author)

  10. Electron beams in radiation therapy

    International Nuclear Information System (INIS)

    Bruinvis, I.A.D.

    1987-01-01

    Clinical electron beams in interaction with beam flattening and collimating devices are studied, in order to obtain the means for adequate electron therapy. A treatment planning method for arbitrary field shapes is developed that takes the properties of the collimated electron beams into account. An electron multiple-scattering model is extended to incorporate a model for the loss of electrons with depth, in order to improve electron beam dose planning. A study of ionisation measurements in two different phantom materials yields correction factors for electron beam dosimetry. (Auth.)

  11. SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

    International Nuclear Information System (INIS)

    Williams, C; Crowley, E; Wolfgang, J

    2016-01-01

    Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 and Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on

  12. SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Williams, C [Brigham and Women’s Hospital & Dana Farber Cancer Institute, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Crowley, E; Wolfgang, J [Harvard Medical School, Boston, MA (United States); Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 and Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on

  13. Evaluation of multimodality treatment for advanced pancreatic cancer. Special reference to intraoperative vs. external radiation therapy

    International Nuclear Information System (INIS)

    Wakasugi, Hideyuki; Funakoshi, Akihiro; Seo, Yousuke; Iguchi, Haruo; Wada, Susumu

    1999-01-01

    Intraoperative radiation therapy (IORT)+postoperative external beam radiation therapy (ERT) with chemotherapy and ERT alone with chemotherapy have been performed in our hospital for unresectable, especially locally advanced, pancreatic cancer. We compared the former method with the latter. Chemotherapy was performed together with radiation, using 5-FU, CDDP, and MMC. IORT+ERT was successful in only half of the treated patients, while ERT alone was successful in almost all of the patients. As a result, the doses of radiation were often shorter in patients treated by the former method compared to the latter method. Both methods, when completed for locally advanced pancreatic cancer (stage IVa), produced good effects on tumor markers, tumor size and pain. Furthermore, the latter method was better than the former in improving the survival time and quality of life (QOL). Therefore, ERT is a practical and useful method for patients with locally advanced pancreatic cancer. (author)

  14. The role of intraoperative radiation therapy in patients with pancreatic cancer.

    Science.gov (United States)

    Palta, Manisha; Willett, Christopher; Czito, Brian

    2014-04-01

    Intraoperative radiation therapy (IORT) techniques allow for the delivery of high doses of radiation therapy while excluding part or all of the nearby dose-limiting sensitive structures. Therefore, the effective radiation dose is increased and local tumor control potentially improved. This is pertinent in the case of pancreatic cancer because local failure rates are as high as 50%-80% in patients with resected and locally advanced disease. Available data in patients receiving IORT after pancreaticoduodenectomy reveal an improvement in local control, though overall survival benefit is unclear. Series of patients with locally advanced pancreatic cancer also suggest pain relief, and in select studies, improved survival associated with the inclusion of IORT. At present, no phase III data clearly supports the use of IORT in the management of pancreatic cancer. © 2013 Published by Elsevier Inc.

  15. An Innovative Tool for Intraoperative Electron Beam Radiotherapy Simulation and Planning: Description and Initial Evaluation by Radiation Oncologists

    Energy Technology Data Exchange (ETDEWEB)

    Pascau, Javier, E-mail: jpascau@mce.hggm.es [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Departamento de Bioingenieria e Ingenieria Aeroespacial, Universidad Carlos III de Madrid, Madrid (Spain); Santos Miranda, Juan Antonio [Servicio de Oncologia Radioterapica, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain); Calvo, Felipe A. [Servicio de Oncologia Radioterapica, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain); Departamento de Oncologia, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Bouche, Ana; Morillo, Virgina [Consorcio Hospitalario Provincial de Castellon, Castellon (Spain); Gonzalez-San Segundo, Carmen [Servicio de Oncologia Radioterapica, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain); Ferrer, Carlos; Lopez Tarjuelo, Juan [Consorcio Hospitalario Provincial de Castellon, Castellon (Spain); and others

    2012-06-01

    Purpose: Intraoperative electron beam radiation therapy (IOERT) involves a modified strategy of conventional radiation therapy and surgery. The lack of specific planning tools limits the spread of this technique. The purpose of the present study is to describe a new simulation and planning tool and its initial evaluation by clinical users. Methods and Materials: The tool works on a preoperative computed tomography scan. A physician contours regions to be treated and protected and simulates applicator positioning, calculating isodoses and the corresponding dose-volume histograms depending on the selected electron energy. Three radiation oncologists evaluated data from 15 IOERT patients, including different tumor locations. Segmentation masks, applicator positions, and treatment parameters were compared. Results: High parameter agreement was found in the following cases: three breast and three rectal cancer, retroperitoneal sarcoma, and rectal and ovary monotopic recurrences. All radiation oncologists performed similar segmentations of tumors and high-risk areas. The average applicator position difference was 1.2 {+-} 0.95 cm. The remaining cancer sites showed higher deviations because of differences in the criteria for segmenting high-risk areas (one rectal, one pancreas) and different surgical access simulated (two rectal, one Ewing sarcoma). Conclusions: The results show that this new tool can be used to simulate IOERT cases involving different anatomic locations, and that preplanning has to be carried out with specialized surgical input.

  16. Experimental study of the intra-operative radiation therapy for pancreatic cancer

    International Nuclear Information System (INIS)

    Kodera, Taro; Matsuno, Seiki; Kobari, Masao; Akaishi, Satoshi; Sakamoto, Kiyohiko

    1988-01-01

    The radiosensitivity of pancreatic cancer, optimum dose of irradiation and the effect of 1-[4'-Hydroxy-2'-Butenoxy) Methyl]-2-Nitrosoimidaole (RK-28) on irradiation were investigated using an experimental pancreatic cancer of hamster and the following results were obtained: i) The mean lethal dose (Do) and the 50 % tumor control dose (TCD 50 ) against the pancreatic cancer were 3.5 Gy and 73.7 ± 6.9 Gy, respectively. These results indicate that the pancreatic cancer is resistant to irradiation, which could be explained by the existence of hypoxic cells consisting of 35 % of the tumor. ii) The dose of intraoperative irradiation (10 - 40 Gy) seemed to be insufficient to bring long-term anti-tumor effect and long-term survival since that dose resulted in only temporary regression of the tumor. iii) The hypoxic cell sensitizer (RK28), which is known to specifically enhance the sensitivity of hypoxic cells to irradiation, lowered TCD 50 of the pancreatic cancer to 53.8 ± 1.57 Gy. Therefore, RK-28 was effective in the treatment of the experimental pancreatic cancer (the enhancement ratio : 1.37). When combined with 30 or 40 Gy of irradiation, which is applicable to intraoperative irradiation, RK-28 induced a longer period of tumor suppression and a higher tumor regression ratio than irradiation alone. These results indicate that RK-28 significantly increases the effect of intraoperative irradiation and this combination therapy could possibly induce remarkable effect on tumor regression and long-term survival. (author)

  17. The influence of intraoperative radiation therapy (IORT) on outcome of surgically resectable adenocarcinoma of the pancreas

    International Nuclear Information System (INIS)

    Ono, Mark K.; Ahmad, Neelofur; Huq, M. Saiful; Vernick, Jerome; Rosato, Francis E.

    1996-01-01

    Purpose/Objective: Surgical resection offers an opportunity for long term survival for patients with cancer of the pancreas. Unfavorable pathologic prognostic factors following resection of these lesions include positive surgical margins and positive lymph nodes. The purpose of this study was to analyze the influence of IORT on survival of completely resected adenocarcinomas of the pancreas in patients with these poor pathologic features. Materials and Methods: From 1988 to 1994, 391 newly diagnosed patients with carcinoma of the pancreas were seen at Thomas Jefferson University Hospital. Pre-operative work-up identified 166 patients with clinically localized disease. These patients were evaluated by the Department of Radiation Oncology for possible treatment with IORT. These patients underwent exploratory laparotomy and 26 had a complete surgical resection (i.e. Whipple procedure or total pancreatectomy) and received IORT. Mean patient age was 66 ± 2 years (range: 43-80) with 15 male and 11 female patients. All patients had histologically proven adenocarcinoma of the pancreas. IORT was delivered to the surgical tumor bed and regional lymph nodes with a median dose of 15.0 Gy (range: 10.0-20.0 Gy). Technique, field size, and energy of the electron radiation beam varied with the clinical situation and were determined by the radiation oncologist. All 26 patients received post-operative external beam radiation therapy (EBRT) with concurrent weekly 5-FU chemotherapy. Follow-up times ranged from one to 84 months (median: 15 months). Actuarial survival rates were calculated by the Life-Table Method. Patient outcome was evaluated with respect to surgical margin and pathological lymph node status. Results: The overall actuarial 2-year survival rate was 44%. The overall median survival time (MST) was 19 months. At pathological review, five of the 26 patients (19%) were found to have positive surgical margins, four of whom also had involved lymph nodes. Thus, only one

  18. Safety and efficacy of enzyme targeting intraoperative radiosensitization therapy (KORTUC-IORT) for advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Nishioka, Akihito; Hamada, Norihiko; Kariya, Shinji; Ogawa, Yasuhiro

    2012-01-01

    We developed a new radiosensitizer injection containing hydrogen peroxide and sodium hyaluronate just followed by intraoperative radiotherapy (IORT) for locally advanced pancreatic cancer, named KORTUC-IORT (Kochi Oxydol-Radiation Therapy for Unresectable Carcinoma + IORT). Fourteen patients were treated with KORTUC-IORT, external beam radiotherapy (EBRT), and systemic chemotherapy. With KORTUC-IORT, the agent containing hydrogen peroxide and sodium hyaluronate, was injected into tumor tissue just prior to administration of IORT under ultrasonic guidance. All treatments related with KORTUC-IORT were well tolerated, with few adverse effects. One year survival rate is 67% and median survival period is 15 months. The present formulation can be delivered safely and effectively under the conditions used. (author)

  19. High-dose-rate intraoperative radiation therapy: the nuts and bolts of starting a program

    Science.gov (United States)

    Moningi, Shalini; Armour, Elwood P.; Terezakis, Stephanie A.; Efron, Jonathan E.; Gearhart, Susan L.; Bivalacqua, Trinity J.; Kumar, Rachit; Le, Yi; Kien Ng, Sook; Wolfgang, Christopher L.; Zellars, Richard C.; Ellsworth, Susannah G.; Ahuja, Nita

    2014-01-01

    High-dose-rate intraoperative radiation therapy (HDR-IORT) has historically provided effective local control (LC) for patients with unresectable and recurrent tumors. However, IORT is limited to only a few specialized institutions and it can be difficult to initiate an HDR-IORT program. Herein, we provide a brief overview on how to initiate and implement an HDR-IORT program for a selected group of patients with gastrointestinal and pelvic solid tumors using a multidisciplinary approach. Proper administration of HDR-IORT requires institutional support and a joint effort among physics staff, oncologists, surgeons, anesthesiologists, and nurses. In order to determine the true efficacy of IORT for various malignancies, collaboration among institutions with established IORT programs is needed. PMID:24790628

  20. Intraoperative use of an open midfield MR scanner in the surgical treatment of cerebral gliomas; Intraoperative Nutzung eines offenen Mittelfeld-MRT waehrend der chirurgischen Therapie zerebraler Gliome

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Dietrich, J.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany); Trantakis, C. [Klinik und Poliklinik fuer Neurochirurgie, Univ. Leipzig (Germany)

    2003-07-01

    von 29% auf 10% bei Glioblastomen erreicht werden. Der intraoperative Einsatz der MRT ermoeglicht eine deutliche Optimierung der mikrochirurgischen Resektion sowohl bei Patienten mit niedriggradigem Gliom als auch bei Patienten mit Glioblastom (intraoperative MRT, intrazerebrale Gliome, Therapie). (orig.)

  1. Extrahepatic portal vein occlusion without recurrence after pancreaticoduodenectomy and intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Mitsunaga, Shuichi; Kinoshita, Taira; Kawashima, Mitsuhiko; Konishi, Masaru; Nakagohri, Toshio; Takahashi, Shinichiro; Gotohda, Naoto

    2006-01-01

    Purpose: Although there are no definitive studies that characterize the survival benefit of intraoperative radiation therapy (IORT), the therapy does not seem to produce significant complication. In our institution, pancreaticoduodenectomy (PD) and IORT are often complicated by the development of extrahepatic portal vein occlusion (EHPO). The aim of this study was to characterize the phenomenon of EHPO after PD and IORT. Methods and Materials: Between September 1992 and December 2001, 107 patients received macroscopic curative PD for periampullary disease in our institution. IORT (radiation dose: 20 Gy) was performed in 53 of these patients. Criteria for diagnosis of EHPO were as follows: (1) computerized tomography findings of occlusive extrahepatic portal vein (2) symptoms of portal hypertension, and (3) confirmation to exclude tumor recurrence from origin of EHPO, because this study examined whether EHPO was a complication of PD and IORT. Results: EHPO was diagnosed in 12 patients. Among patient and operative variables, IORT was the only statistically significant factor associated with a diagnosis of EHPO (p = 0.0052). The median developed time to EHPO and overall survival after surgery in EHPO patients were 358 days and 2,562 days, respectively. Eight patients (67%) with EHPO died during the follow-up period. At 5 years after therapy, EHPO was diagnosed in 67% of survivors who had received IORT. Conclusions: Patients undergoing IORT and PD have a relatively high incidence of EHPO, and patients who develop postoperative EHPO have poor prognoses

  2. INTRAOPERATIVE PHOTODYNAMIC THERAPY IN PATIENT WITH STAGE IIIC BREAST CANCER (8 YEARS WITHOUT RECURRENCE

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2017-01-01

    Full Text Available The article presents  a clinical observation  of the patient  of 38 y.o. with cancer of the left breast stage IIIC урТ4bN3М0L1V1. On the 1st  step of the treatment the patient  had 2 courses of CAF neoadjuvant chemotherapy, on the 2nd  step – extended radical mastectomy on the left with intraoperative photodynamic therapy and closure of the defect with ТRАМ-flap, on the 3rd step – continuation of the chemotherapy (8 courses, on the 4th  step  – radiation  therapy  to the chest wall on the left and zones of regional lymph drainage, targeted therapy  with herceptin  a (1 year. Four years later a silicone implant was inserted  into the left breast. Corrective surgery (reduction  mammoplasty on the right side was performed in april, 2017. Currently, the patient has remission of the disease of the left breast, the period of remission accounts for 8 years. 

  3. Delivery of intraoperative radiation therapy after pneumonectomy: experimental observations and early clinical results

    International Nuclear Information System (INIS)

    Pass, H.I.; Sindelar, W.F.; Kinsella, T.J.

    1987-01-01

    Intraoperative radiation therapy (IORT) is capable of delivering high doses of radiation to mediastinal structures while sparing lung parenchyma, heart, and other locoregional tissues. A canine model of pulmonary resection and IORT was investigated by performing a pneumonectomy in 15 adult foxhounds followed by 0 cGy, 2000 cGy, 3000 cGy, 4000 cGy. No clinical complications developed in 4 animals in the 2000-cGy group. However, 2 of the 8 animals given a high dose died of esophageal hemorrhage or carinal necrosis. Esophagitis occurred in 10 of 12 animals, and none of the animals experienced bronchial stump dehiscence. In a limited Phase I protocol, 4 patients with non-small cell lung cancer were treated with resection and 2500 cGy of IORT to two separate ports encompassing the superior and inferior mediastinum. Two patients experienced life-threatening bronchopleural fistulas, and 2 patients died as a consequence of esophageal problems. One patients had recurrence with brain metastases, and the 1 long-term survivor is free from disease. As opposed to the animal model of thoracic IORT, the clinical study demonstrated major toxicity with respiratory and esophageal morbidity. The therapeutic usefulness of thoracic IORT in the management of lung cancer must be questioned in view of this small but consistent series of patients. Further carefully designed clinical studies using lower doses of IORT are needed

  4. High-dose rate intra-operative radiation therapy for local advanced and recurrent colorectal cancer

    International Nuclear Information System (INIS)

    Harrison, L.B.; Mychalczak, B.; Enker, W.; Anderson, L.; Cohen, A.E.; Minsky, B.

    1996-01-01

    In an effort to improve the local control for advanced and recurrent cancers of the rectum, we have integrated high-dose rate intra-operative radiation therapy (HDR-IORT) into the treatment program. Between 11/92 and 10/95, 47 patients (pts) were treated. There were 26 males and 21 females whose ages ranged from 30-80 (median = 62) years. There were 19 pts with primary unresectable rectal cancer, and 28 pts who were treated for recurrent rectal cancer. Histology was adenocarcinoma - 45 pts, squamous cancer - 2 pts. The range of follow-up is 1-34 months (median = 14 months). The majority of primary unresectable pts received pre-operative radiation therapy (4500-5040 cGy) with chemotherapy (5-FU with Leucovorin) 4-6 weeks later, they underwent resection + HDR-IORT (1200 cGy). For the 28 pts with recurrent cancer, the majority received surgery and HDR-IORT alone because they had received prior RT. For the pts with primary unresectable disease, actuarial 2-year local control was 77%, actuarial distant metastasis-free survival was 71%, disease free survival was 66%, and overall survival was 84%. For those pts with recurrent disease, actuarial 2-year local control rate was 65%, distant metastasis-free survival was 65%, disease free survival was 47%, and overall survival was 61%. Complications occurred in 36%. There were no cases where the anatomical distribution of disease, or technical limitations prevented the adequate delivery of HDR-IORT. We conclude that this technique was most versatile, and enabled all appropriate pts to receive IORT. The preliminary data in terms of local control are encouraging, even for the poor prognostic sub-group of pts with recurrent cancer

  5. Single high dose intraoperative electrons for advanced stage pancreatic cancer: Phase I pilot study

    International Nuclear Information System (INIS)

    Goldson, A.L.; Ashaveri, E.; Espinoza, M.C.

    1981-01-01

    Phase I toxicity studies with intraoperative radiotherapy proved to be a feasible adjunct to surgery for unresectable malignancies of the pancreas at Howard University Hospital. There have been minimal side effects or complications related to the combination of limited surgical decompression and intraoperative radiotherapy alone. The toxic effects of intraoperative radiotherapy on normal tissues is being assessed on a dose volume basis. Doses of 2000 to 2500 rad in a single exposure to include the pancreas, regional nodes and duodenum are acceptable if the total treatment volume is less than or equal to 100 cm. The tumoricidal effects on the cancer are demonstratable when one reviews the pathological specimens that illustrate massive tumor necrosis and fibros replacement, but in all cases reviewed, viable cancer was noted. Intraoperative radiotherapy, therefore, represents a significant boost dose for resectable, partially resectable or non-resectable tumors when added to conventional external beam irradiation and/or chemotherapy. Preliminary clinical data and minimal toxicity justifies further investigation

  6. Intraoperative Radiation Therapy in Resected Pancreatic Carcinoma: Long-Term Analysis

    International Nuclear Information System (INIS)

    Valentini, Vincenzo; Morganti, Alessio G.; Macchia, Gabriella; Mantini, Giovanna; Mattiucci, Gian C.; Brizi, M. Gabriella; Alfieri, Sergio; Bossola, Maurizio; Pacelli, Fabio; Sofo, Luigi; Doglietto, Giovanbattista; Cellini, Numa

    2008-01-01

    Purpose: The combination of external radiotherapy (RT) plus intraoperative radiotherapy (IORT) in patients with pancreatic cancer is still debated. This study presents long-term results (minimum follow-up, 102 months) for 26 patients undergoing integrated adjuvant RT (external RT + IORT). Methods and Materials: From 1990 to 1995, a total of 17 patients with pancreatic cancer underwent IORT (10 Gy) and postoperative external RT (50.4 Gy). Preoperative 'flash' RT was included for the last 9 patients. The liver and pancreatic head received 5 Gy (two 2.5-Gy fractions) the day before surgery. In the subsequent period (1996-1998), 9 patients underwent preoperative concomitant chemoradiation (39.6 Gy) with 5-fluorouracil, IORT (10 Gy), and adjuvant chemotherapy. Results: Preoperative chemoradiation was completed in all patients, whereas postoperative therapy was completed in 13 of 17 patients. All 26 patients underwent pancreatectomy (25 R0 and one R1 resections). One patient died of postoperative complications (3.8%) not related to IORT. The 9 patients undergoing concomitant chemoradiation were candidates for adjuvant chemotherapy; however, only 4 of 9 underwent adjuvant chemotherapy. At last follow-up, 4 patients (15.4%) were alive and disease free. Disease recurrence was documented in 20 patients (76.9%). Sixteen patients (61.5%) showed distant metastasis, and 5 patients (19.2%) showed local recurrence. The incidence of local recurrence in R0 patients was 4 of 25 (16.0%). The overall 5-year survival rate was 15.4%. There was significant correlation with overall survival of tumor diameter (p = 0.019). Conclusions: The incidence of local recurrence in this long follow-up series (19.2%) was definitely less than that reported in other studies of adjuvant RT (∼50%), suggesting a positive impact on local control of integrated adjuvant RT (IORT + external RT)

  7. Tolerance of the canine bladder to intraoperative radiation therapy: an experimental study

    International Nuclear Information System (INIS)

    Kinsella, T.J.; Sindelar, W.F.; DeLuca, A.M.; Barnes, M.; Tochner, Z.; Mixon, A.; Glatstein, E.

    1988-01-01

    An experimental study of bladder tolerance to intraoperative radiotherapy (IORT) was designed using a large animal model (adult American Foxhounds, weight 25-30 kg) to access acute and late radiation effects. Dogs were subjected to laparotomy where the bladder was mobilized and IORT was delivered using a 5 cm circular cone through a cystotomy incision with 12 MeV electrons. The bladder trigone including both ureteral orifices and the proximal urethra was irradiated in groups of 3 dogs with doses of 0, 20, 25, 30, 35, and 40 Gy. Dogs were followed clinically with repeat urinalysis, intravenous pyelogram (IVP), and cystometrogram at 1 month and then Q6 months for up to 4 years. One dog from each dose group was sacrificed electively at 1 and 2 years, whereas the other dog is being followed clinically for a minimum of 4 years. Complete autopsies were performed with particular attention to genitourinary and pelvic structures. No clinically detectable acute toxicity resulted from IORT to the bladder. Three of 15 IORT dogs (1 each at 25, 35, and 40 Gy) showed obstruction of a ureteral orifice with 2 dogs dying of renal failure secondary to bilateral hydronephrosis within 1-2 years of treatment. The remaining 12 IORT dogs and 3 control dogs have normal repeat IVP's and renal function with up to 4 years of follow-up. Serial cystometry demonstrates no major loss of bladder contractility or volume. At autopsy, histological changes of mucosal thinning and telangiectasia with submucosal fibrosis were confined to the IORT field and appeared dose-related. However, the bladder epithelium remained intact at all doses. The ureterovesical junction in animals receiving 20 Gy showed mild fibrosis of the lamina propria and moderate chronic inflammation. Above 20 Gy, these histological changes at the U-V junction were more pronounced with gross stenosis in 3 animals as predicted by the IVP

  8. In vivo dosimetry in intraoperative electron radiotherapy. microMOSFETs, radiochromic films and a general-purpose linac

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Tarjuelo, Juan; Marco-Blancas, Noelia de; Santos-Serra, Agustin; Quiros-Higueras, Juan David [Consorcio Hospitalario Provincial de Castellon, Servicio de Radiofisica y Proteccion Radiologica, Castellon de la Plana (Spain); Bouche-Babiloni, Ana; Morillo-Macias, Virginia; Ferrer-Albiach, Carlos [Consorcio Hospitalario Provincial de Castellon, Servicio de Oncologia Radioterapica, Castellon de la Plana (Spain)

    2014-11-15

    In vivo dosimetry is desirable for the verification, recording, and eventual correction of treatment in intraoperative electron radiotherapy (IOERT). Our aim is to share our experience of metal oxide semiconductor field-effect transistors (MOSFETs) and radiochromic films with patients undergoing IOERT using a general-purpose linac. We used MOSFETs inserted into sterile bronchus catheters and radiochromic films that were cut, digitized, and sterilized by means of gas plasma. In all, 59 measurements were taken from 27 patients involving 15 primary tumors (seven breast and eight non-breast tumors) and 12 relapses. Data were subjected to an outliers' analysis and classified according to their compatibility with the relevant doses. Associations were sought regarding the type of detector, breast and non-breast irradiation, and the radiation oncologist's assessment of the difficulty of detector placement. At the same time, 19 measurements were carried out at the tumor bed with both detectors. MOSFET measurements (D = 93.5 %, s{sub D} = 6.5 %) were not significantly shifted from film measurements (D = 96.0 %, s{sub D} = 5.5 %; p = 0.109), and no associations were found (p = 0.526, p = 0.295, and p = 0.501, respectively). As regards measurements performed at the tumor bed with both detectors, MOSFET measurements (D = 95.0 %, s{sub D} = 5.4 %) were not significantly shifted from film measurements (D = 96.4 %, s{sub D} = 5.0 %; p = 0.363). In vivo dosimetry can produce satisfactory results at every studied location with a general-purpose linac. Detector choice should depend on user factors, not on the detector performance itself. Surgical team collaboration is crucial to success. (orig.) [German] Die In-vivo-Dosimetrie ist wuenschenswert fuer die Ueberpruefung, Registrierung und die eventuelle Korrektur der Behandlungen in der IOERT (''Intraoperative Electron Radiation Therapy''). Unser Ziel ist die Veroeffentlichung unserer Erfahrungen beim

  9. An experimental attenuation plate to improve the dose distribution in intraoperative electron beam radiotherapy for breast cancer.

    Science.gov (United States)

    Oshima, T; Aoyama, Y; Shimozato, T; Sawaki, M; Imai, T; Ito, Y; Obata, Y; Tabushi, K

    2009-06-07

    Intraoperative electron beam radiotherapy (IOERT) is a technique in which a single-fraction high dose is intraoperatively delivered to subclinical tumour cells using an electron beam after breast-conserving surgery. In IOERT, an attenuation plate consisting of a pair of metal disks is commonly used to protect the normal tissues posterior to the breast. However, the dose in front of the plate is affected by backscatter, resulting in an unpredictable delivered dose to the tumour cells. In this study, an experimental attenuation plate, termed a shielding plate, was designed using Monte Carlo simulation, which significantly diminished the electron beam without introducing any backscatter radiation. The plate's performance was verified by measurements. It was made of two layers, a first layer (source side) of polymethyl methacrylate (PMMA) and a second layer of copper, which was selected from among other metals (aluminium, copper and lead) after testing for shielding capability and the range and magnitude of backscatter. The optimal thicknesses of the PMMA (0.71 cm) and copper (0.3 cm) layers were determined by changing their thicknesses during simulations. On the basis of these results, a shielding plate was prototyped and depth doses with and without the plate were measured by radiophotoluminescence glass dosimeters using a conventional stationary linear accelerator and a mobile linear accelerator dedicated for IOERT. The trial shielding plate functioned as intended, indicating its applicability in clinical practice.

  10. Review of electron beam therapy physics

    International Nuclear Information System (INIS)

    Hogstrom, Kenneth R; Almond, Peter R

    2006-01-01

    For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

  11. Effects of intraoperative electron irradiation in the dog on cell turnover in intact and surgically-anastomosed aorta and intestine

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Morrow, B.M.; Travis, E.L.; Tepper, J.; Merkel, A.B.; Kranda, K.; Terrill, R.

    1983-01-01

    Adults dogs were subjected to laparotomy and intraoperative electron irradiation after division and reanastomosis of aorta or after construction of a blind loop of small intestine having a transverse suture line and an end-to-side anastomosis. Dogs received intraoperative irradiation of both intact and anastomosed aorta or intestine in doses of 0, 2000, 3000, or 4500 rad. Animals were sacrificed at seven days or three months following treatment. At 24 hours prior to sacrifice, dogs received 5 mCi tritiated thymidine intravenously. Irradiated and non-irradiated segments of aorta and small intestine, including intact and anastomotic regions, were analyzed for tritiated thymidine incorporation and were subjected to autoradiography. Incorporation studies showed diminution in tritiated thymidine uptake by irradiated portions of aorta and small intestine, in both intact and anastomotic regions. Autoradiograms revealed that irradiated areas of intact or anastomotic aorta or intestine had diminished labeling of stromal cells, suggesting a lowered cell proliferative capacity of irradiated tissue compared to non-irradiated portions. Inflammatory cells showed similar labeling indices in irradiated and non-irradiated tissues, both intact and surgically-manipulated, suggesting that irradiation does not significantly affect a subsequent local inflammatory response. Radiation-induced decreases in tritiated thymidine incoporation in irradiated aorta and small intestine were generally more marked at seven days than at three months following irradiation, suggesting that radiation-induced depression of cell turnover rates decreases with time

  12. Prospective Study of Local Control and Late Radiation Toxicity After Intraoperative Radiation Therapy Boost for Early Breast Cancer

    International Nuclear Information System (INIS)

    Chang, David W.; Marvelde, Luc te; Chua, Boon H.

    2014-01-01

    Purpose: To report the local recurrence rate and late toxicity of intraoperative radiation therapy (IORT) boost to the tumor bed using the Intrabeam System followed by external-beam whole-breast irradiation (WBI) in women with early-stage breast cancer in a prospective single-institution study. Methods and Materials: Women with breast cancer ≤3 cm were recruited between February 2003 and May 2005. After breast-conserving surgery, a single dose of 5 Gy IORT boost was delivered using 50-kV x-rays to a depth of 10 mm from the applicator surface. This was followed by WBI to a total dose of 50 Gy in 25 fractions. Patients were reviewed at regular, predefined intervals. Late toxicities were recorded using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring systems. Results: Fifty-five patients completed both IORT boost and external-beam WBI. Median follow-up was 3.3 years (range, 1.4-4.1 years). There was no reported locoregional recurrence or death. One patient developed distant metastases. Grade 2 and 3 subcutaneous fibrosis was detected in 29 (53%) and 8 patients (15%), respectively. Conclusions: The use of IORT as a tumor bed boost using kV x-rays in breast-conserving therapy was associated with good local control but a clinically significant rate of grade 2 and 3 subcutaneous fibrosis

  13. Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

    International Nuclear Information System (INIS)

    Hanna, Samir Abdallah; Simões Dornellas de Barros, Alfredo Carlos; Martins de Andrade, Felipe Eduardo; Barbosa Bevilacqua, Jose Luiz; Morales Piato, José Roberto; Lopes Pelosi, Edilson; Martella, Eduardo; Fernandes da Silva, João Luis; Andrade Carvalho, Heloisa de

    2014-01-01

    Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was

  14. Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, Samir Abdallah, E-mail: samir.hanna@hsl.org.br [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Simões Dornellas de Barros, Alfredo Carlos; Martins de Andrade, Felipe Eduardo; Barbosa Bevilacqua, Jose Luiz [Department of Mastology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Morales Piato, José Roberto [Department of Mastology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Department of Gynecology, Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo (Brazil); Lopes Pelosi, Edilson [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Martella, Eduardo [Department of Radiation Oncology, Hospital Perola Byington, Sao Paulo (Brazil); Fernandes da Silva, João Luis [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Andrade Carvalho, Heloisa de [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Department of Radiology and Oncology, Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo (Brazil)

    2014-08-01

    Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was

  15. Characterization of a team intraoperative Radiation therapy and measurement of dose in skin with film radiochromic

    International Nuclear Information System (INIS)

    Onses Segarra, A.; Sancho Kolster, I.; Eraso Urien, A.; Pla Farnos, M. J.; Picon Olmos, C.

    2015-01-01

    This paper presents the results of the initial reference state of intraoperative radiotherapy equipment lntraBeam, for performing breast treatments are analyzed. To the initial reference team was established for the following dosimetric and geometric beam parameters: percentage depth dose, beam quality, isotropy, linearity and mechanical and geometric integrity for both the source RX as for different spherical applicators of the team. Based on these checks, a program of periodic quality control was established. One of the exclusion criteria for this treatment is that the tumor is less than l cm of the skin, yaque give doses received in this organ can be high. For this reason it is important to know exactly the absorbed dose in skin during these treatments. In this regard we have implemented a system for measuring the skin dose during treatment with Radiochromic film, placing 4 film segments in fixed positions of the skin around the surgical incision. It .ha obtained calibration curve of sterilized films and compared the results with a calibration beam megavoltage. The results of the skin dose measurements are compared with theoretical estimates given by the planning system equipment. The results indicate the need to measure individually the skin dose for these treatments. (Author)

  16. Cosmetic Outcome and Seroma Formation After Breast-Conserving Surgery With Intraoperative Radiation Therapy Boost for Early Breast Cancer

    International Nuclear Information System (INIS)

    Senthi, Sashendra; Link, Emma; Chua, Boon H.

    2012-01-01

    Purpose: To evaluate cosmetic outcome and its association with breast wound seroma after breast-conserving surgery (BCS) with targeted intraoperative radiation therapy (tIORT) boost for early breast cancer. Methods and Materials: An analysis of a single-arm prospective study of 55 patients with early breast cancer treated with BCS and tIORT boost followed by conventional whole breast radiation therapy (WBRT) between August 2003 and January 2006 was performed. A seroma was defined as a fluid collection at the primary tumor resection site identified clinically or radiologically. Cosmetic assessments using the European Organization for Research and Treatment of Cancer rating system were performed at baseline before BCS and 30 months after WBRT was completed. Results: Twenty-eight patients (51%) developed a seroma, with 18 patients (33%) requiring at least 1 aspiration. Tumor location was significantly associated with seroma formation (P=.001). Ten of 11 patients with an upper inner quadrant tumor developed a seroma. Excellent or good overall cosmetic outcome at 30 months was observed in 34 patients (62%, 95% confidence interval 53%-80%). Seroma formation was not associated with the overall cosmetic result (P=.54). Conclusion: BCS with tIORT boost followed by WBRT was associated with an acceptable cosmetic outcome. Seroma formation was not significantly associated with an adverse cosmetic outcome.

  17. The short and long term effects of intraoperative electron beam radiotherapy (IORT) on thoracic organs after pneumonectomy an experimental study in the canine model

    NARCIS (Netherlands)

    de Boer, Willem; Mehta, DM; Timens, W; Hoekstra, HJ

    1999-01-01

    Purpose: The tolerance of mediastinal structures and thoracic organs to intraoperative radiotherapy (IORT) was investigated in the canine model. Methods and Materials: Twenty-two adult beagles divided into three groups were subjected to a left pneumonectomy and IORT (10 MeV electrons) at doses of 20

  18. Intraoperative Radiation Therapy for Locally Advanced and Recurrent Soft-Tissue Sarcomas in Adults

    International Nuclear Information System (INIS)

    Tran, Phuoc T.; Hara, Wendy; Su Zheng; Lin, H. Jill; Bendapudi, Pavan K.; Norton, Jeffrey; Teng, Nelson; King, Christopher R.; Kapp, Daniel S.

    2008-01-01

    Purpose: To analyze the outcomes of and identify prognostic factors for patients treated with surgery and intraoperative radiotherapy (IORT) for locally advanced and recurrent soft-tissue sarcoma in adults from a single institution. Methods and Materials: We retrospectively reviewed 50 consecutive patients treated with IORT to 62 sites of disease. Primary sites included retroperitoneum-pelvis (78%), extremity (8%), and other (14%). Seventy percent of patients had recurrent disease failing prior surgery (70%) and/or radiation (32%). Mean disease-free interval (DFI) before IORT was 1.9 years (range, 2 weeks-5.4 years). The IORT was delivered with orthovoltage X-rays using individually sized beveled cone applicators. Clinical characteristics were as follows: mean tumor size, 10 cm (range, 1-25 cm); high-grade histologic subtype (72%); and mean dose, 1,159 cGy (range, 600-1,600 cGy). Postoperative radiation or chemotherapy was administered to 37% of IORT Sites and 32% of patients, respectively. Outcomes measured were infield control (IFC), locoregional control (LRC), distant metastasis-free survival (DMFS), disease-specific survival (DSS), and treatment-related complications. Mean and median follow-up of alive patients were 59 and 35 months, respectively. Results: Kaplan-Meier 5-year IFC, LRC, DMFS, and DSS probabilities for the entire group were 55%, 26%, 51%, and 25%, respectively. Prognostic factors found to be significant (p < 0.05) on multivariate analysis were prior DFI and tumor size for LRC, extremity location and leiomyosarcoma histologic subtype for DMFS, and prior DFI for DSS. Our cohort had five Grade 3/4 complications associated with treatment or a 5-year Kaplan-Meier Grade 3/4 complication-free survival rate of 85%. Conclusions: IORT after tumor reductive surgery is well tolerated and seems to confer IFC in carefully selected patients

  19. The ultrastructure of tumor cells in patients with rectal cancer after pre-operative irradiation and intra-operative cryotherapy

    International Nuclear Information System (INIS)

    Vyinnik, Yu.O.; Kotenko, O.Je.; Nevzorov, V.P.; Chyibyisov, L.P.

    2000-01-01

    Electronic microscopy of the tumor cells was performed to confirm the efficacy of combined pre-operative gamma-therapy and intraoperative cryotherapy (CT). Pre-operative irradiation at the dose of 20 Gy accompanied by intra-operative cryotherapy caused the changes in the ultrastructure, the depth and degree of which allow to consider them destructive and irreversible

  20. Intra-operative radiation therapy in cancer of the pancreas. La radiotherapie peroperatoire dans les cancers du pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J.B.; Gu, S.D.; Saint-Aubert, B.; Joyeux, H.; Solassol, C.; Pujol, H. (Centre Regional de Lutte contre le Cancer, 34 - Montpellier (FR))

    1991-03-01

    We report our experience concerning 22 pancreatic carcinoma bearing patients treated with intra-operative radiation therapy (IORT) after complete surgical excision: duodenopancreatectomy: 15 patients; isthmic and caudal pancreatectomy: 2 patients; total pancreatectomy: 5 patients. The dose delivered to the tumor bed was 20 Gy in 12 patients, 18 Gy in 3 patients and 15 Gy in 7 patients. Three patients died within the 1st month post-surgery from intercurrent diseases. Post-operative morbidity was not significantly modified by IORT as compared to purely surgical treated patients. Out of 19 evaluable patients, we observed local control in 16 patients (79.4%). Causes of death (15/19 patients) were: distant metastases with local control: 7 patients; in situ local failure: 3 patients; regional recurrence outside of the IORT fields: 2 patients; intercurrent diseases: 3 patients. Four patients are still alive without evolutive disease. The median overall survival is 6 months. The mean overall survival is 10.56 months. Excluding patients who died from complications and intercurrent diseases, the median survival is 10 mths and the mean survival 14.5 mths. These results emphasize the improvement in local control with IORT, but without significant improvement in survival which is dependent on local evolution and also systemic disease.

  1. Treatment results by uneven fractionated irradiation, low-dose rate telecobalt therapy as a boost, and intraoperative irradiation for malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Shogo; Takai, Yoshihiro; Nemoto, Kenji; Ogawa, Yoshihiro; Kakuto, Yoshihisa; Hoshi, Akihiko; Sakamoto, Kiyohiko; Kayama, Takamasa; Yoshimoto, Takashi (Tohoku Univ., Sendai (Japan). School of Medicine)

    1992-08-01

    The prognosis of malignant glioma is extremely poor. We applied conventionally fractionated irradiation combined with 1-(4-aminio-2-methyl-5-pyrimidinyl)methyl-3-(2-chloroethyl)-3-nitrosourea (ACNU), uneven fractionated irradiation with ACNU, low dose rate telecobalt therapy as a boost, and intraoperative irradiation against 110 malignant gliomas to investigate the efficacy of these methods as alternative treatments for malignant glioma. Although local tumor control by uneven fractionated irradiation was better than that by the other methods, no significant improvement was obtained in survival rates. As a result of multiple regression analysis, age and histology were major factors for survival rates, and the difference of treatment methods was not important. Both low-dose rate telecobalt therapy as a boost and intraoperative irradiation showed little advantage because of the high risk of brain necrosis associated with them. (author).

  2. Intraoperative boron neutron capture therapy for malignant gliomas. First clinical results of Tsukuba phase I/II trial using JAERI mixed thermal-epithermal beam

    International Nuclear Information System (INIS)

    Matsumura, A.; Yamamoto, T.; Shibata, Y.

    2000-01-01

    Since October 1999, a clinical trial of intraoperative boron neutron capture therapy (IOBNCT) is in progress at JRR-4 (Japan Research Reactor-4) in Japan Atomic Energy Research Institute (JAERI) using mixed thermal-epithermal beam (thermal neutron beam I: TNB-I). Compared to pure thermal beam (thermal neutron beam II: TNB-II), TNB-I has an improved neutron delivery into the deep region than TNB-II. The clinical protocol and the preliminary results will be discussed. (author)

  3. Intraoperative anti-thymocyte globulin-Fresenius (ATG-F) administration as induction immunosuppressive therapy in kidney transplantation.

    Science.gov (United States)

    Abou-Jaoude, Maroun M; Almawi, Wassim Y

    2003-07-01

    We reviewed 43 adult kidney transplant patients (32 males and 11 females, 14-68 years of age) performed at our center between July 1999 and February 2002. Donors (39 males and 4 females) comprised two cadaverics, five living-related and 36 living-unrelated; age 18-44 years. Indications for kidney transplantation (KT) were: chronic glomerulonephritis (8), re-transplantation (4) and chronic pyelonephritis (3); kidney disease was unknown in 15 cases. ATG-F was given as a single intra-operative bolus induction therapy in 26 patients; extended ATG-F dose was given in 17 patients because of a high sensitization status, slow graft function (SGF) or development of calcineurin inhibitors toxicity. ATG-F was stopped in seven out of 17 patients because of thrombocytopenia or severe anemia. ATG-F-related fever occurred in six patients. Acute rejection (AR) occurred in eight patients (18%) 5-11 days post-KT. ATG-F was given in three steroid-resistant AR. Infection occurred in 19 patients (44%) for a total of 32 infectious episodes comprising 24 bacterial infections (nine urinary, seven catheter-related and three respiratory), six viral infections (five CMV and one herpes) and two fungal infections (one pulmonary aspergillosis and one catheter-related candidiasis). The hospital stay was 8-75 days for a median of 13 days. The mean serum creatinine upon discharge, at 1 and 6 months after KT were: 2.04+/-0.37, 1.43+/-0.16 and 1.29+/-0.08, respectively. One patient lost his graft on day 9 because of graft microthrombi related to Factor V-Leiden mutation. The 6 months actuarial patient and graft survival were 100 and 97.6%, respectively. ATG-F as a bolus therapy is an effective and safe induction treatment in KT.

  4. Response of the mediastinal and thoracic viscera of the dog to intraoperative radiation therapy (IORT)

    International Nuclear Information System (INIS)

    Barnes, M.; Pass, H.; DeLuca, A.; Tochner, Z.; Potter, D.; Terrill, R.; Sindelar, W.F.; Kinsella, T.J.

    1987-01-01

    IORT may be a potentially useful adjunctive treatment combined with surgery and/or external beam irradiation in treating locally advanced lung and esophageal tumors. To begin investigation of this modality, the tolerance of intact mediastinal structures to IORT was studied using adult American Foxhounds (wt. 25-30 kg). Groups of six animals received IORT to doses of 20, 30, or 40 Gy to two separate intrathoracic ports, using 9 MeV electrons to treat a portion of the collapsed right upper lobe, and 12 MeV electrons to treat the mediastinal structures. A group of three dogs received thoracotomy with sham irradiation. Two dogs from each treatment dose group, as well as one sham-irradiated control, were sacrificed electively at 1, 3, and 12 months following IORT. There were no acute nor late IORT related mortalities. Post-operative weight loss was minimal (average 4.5% of pre-operative weight) for all dogs. Serial esophagrams showed no inflammation or ulceration. No cardiac nor pulmonary changes were noted clinically. At autopsy, the irradiated lung showed evidence of acute pneumonitis at 1 month with progressive fibrosis at 3 months and 1 year. Esophageal reactions were minimal, with only two dogs (one 30 Gy and one 40 Gy) demonstrating histologically confirmed esophagitis at 1 month. Tracheal changes were minimal. Cardiac damage was evident in the right atrial tissues. In several dogs, this cardiac damage ranged from myocardial vascular changes to frank ischemic necrosis noted at 1 and 3 months, and dense fibrosis at 1 year. The phrenic nerves showed normal function, but had evidence of perineural fibrosis. The large vessels demonstrated only mild histologic evidence of irradiation. The results of this large animal study suggest that intact mediastinal structures will tolerate small volume IORT to doses of 20 Gy without significant clinical sequellae. (Abstract Truncated)

  5. Response of the mediastinal and thoracic viscera of the dog to intraoperative radiation therapy (IORT)

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, M.; Pass, H.; DeLuca, A.; Tochner, Z.; Potter, D.; Terrill, R.; Sindelar, W.F.; Kinsella, T.J.

    1987-03-01

    IORT may be a potentially useful adjunctive treatment combined with surgery and/or external beam irradiation in treating locally advanced lung and esophageal tumors. To begin investigation of this modality, the tolerance of intact mediastinal structures to IORT was studied using adult American Foxhounds (wt. 25-30 kg). Groups of six animals received IORT to doses of 20, 30, or 40 Gy to two separate intrathoracic ports, using 9 MeV electrons to treat a portion of the collapsed right upper lobe, and 12 MeV electrons to treat the mediastinal structures. A group of three dogs received thoracotomy with sham irradiation. Two dogs from each treatment dose group, as well as one sham-irradiated control, were sacrificed electively at 1, 3, and 12 months following IORT. There were no acute nor late IORT related mortalities. Post-operative weight loss was minimal (average 4.5% of pre-operative weight) for all dogs. Serial esophagrams showed no inflammation or ulceration. No cardiac nor pulmonary changes were noted clinically. At autopsy, the irradiated lung showed evidence of acute pneumonitis at 1 month with progressive fibrosis at 3 months and 1 year. Esophageal reactions were minimal, with only two dogs (one 30 Gy and one 40 Gy) demonstrating histologically confirmed esophagitis at 1 month. Tracheal changes were minimal. Cardiac damage was evident in the right atrial tissues. In several dogs, this cardiac damage ranged from myocardial vascular changes to frank ischemic necrosis noted at 1 and 3 months, and dense fibrosis at 1 year. The phrenic nerves showed normal function, but had evidence of perineural fibrosis. The large vessels demonstrated only mild histologic evidence of irradiation. The results of this large animal study suggest that intact mediastinal structures will tolerate small volume IORT to doses of 20 Gy without significant clinical sequellae. (Abstract Truncated)

  6. Intraoperative optical assessment of photodynamic therapy response of superficial oral squamous cell carcinoma

    Science.gov (United States)

    Rohrbach, Daniel J.; Rigual, Nestor; Arshad, Hassan; Tracy, Erin C.; Cooper, Michelle T.; Shafirstein, Gal; Wilding, Gregory; Merzianu, Mihai; Baumann, Heinz; Henderson, Barbara W.; Sunar, Ulas

    2016-01-01

    This study investigated whether diffuse optical spectroscopy (DOS) measurements could assess clinical response to photodynamic therapy (PDT) in patients with head and neck squamous cell carcinoma (HNSCC). In addition, the correlation between parameters measured with DOS and the crosslinking of signal transducer and activator of transcription 3 (STAT3), a molecular marker for PDT-induced photoreaction, was investigated. Thirteen patients with early stage HNSCC received the photosensitizer 2-[1-hexyloxyethyl]-2-devinylpyropheophorbide-a (HPPH) and DOS measurements were performed before and after PDT in the operating room (OR). In addition, biopsies were acquired after PDT to assess the STAT3 crosslinking. Parameters measured with DOS, including blood volume fraction, blood oxygen saturation (StO2), HPPH concentration (cHPPH), HPPH fluorescence, and blood flow index (BFI), were compared to the pathologic response and the STAT3 crosslinking. The best individual predictor of pathological response was a change in cHPPH (sensitivity=60%, specificity=100%), while discrimination analysis using a two-parameter classifier (change in cHPPH and change in StO2) classified pathological response with 100% sensitivity and 100% specificity. BFI showed the best correlation with the crosslinking of STAT3. These results indicate that DOS-derived parameters can assess the clinical response in the OR, allowing for earlier reintervention if needed.

  7. Intraoperative photodynamic therapy of bladder cancer with alasens (results of multicenter trial

    Directory of Open Access Journals (Sweden)

    E. V. Filonenko

    2014-01-01

    Full Text Available The results of multicenter prospective trial for efficacy of combined modality treatment: transurethral resection (TUR + photodynamic therapy (PDT with alasens for bladder cancer are represented in the article. Trials were organized by Research Institute of Organic Intermediates and Dyes and conducted according to clinical protocol approved by Ministry of Health of Russia, at the sites of leading Russian cancer clinical centers. The trial included 45 subjects with verified diagnosis of non-muscle-invasive bladder cancer. Patients underwent TUR of bladder with simultaneous PDT as anti-relapse treatment. Alasens was administered to patients as intravesicular instillation of 3% solution in volume of 50 ml with 1.5–2h exposure (prior to TUR. TUR was performed after instillation. PDT session was conducted immediately after the completion of TUR on a single occasion by means of combined local irradiation on tumor bed with diffuse irradiation on whole urinary bladder mucosa (light dose of local irradiation – 100 J/cm2, diffuse irradiation – 20 J/cm2. Good tolerance of the treatment was noticed, there were no complications. Among 45 patients included in the trial, 35 (78% completed 12 month protocol follow-up without relapse. The recurrence of bladder tumor was registered in 10 (22% cases 6–12 months after TUR+PDT including 3 patients with recurrence 6 months after treatment, 3–9 months and 4–12 months. These patients underwent repeated TUR, whereafter their follow-up in the settings of the clinical trial was disposed. Thus, PDT with alasens after TUR allowed to decrease the recurrence rate of non-muscle-invasive bladder cancer for 1st year after treatment to 22% versus 40–80% for TUR as monotherapy according to literature data. The obtained results were comparable by efficiency with TUR combined with methods of adjuvant treatment for bladder tumors (the recurrence rates for 1-year follow-up after TUR+chemotherapy – 36–44%, after TUR

  8. Collimation system for electron arc therapy

    International Nuclear Information System (INIS)

    Brunelli, R.J.; Carter, J.C.

    1984-01-01

    An electron collimation system for electron arc therapy treatments consists of a slit collimation system which is movable with the electron beam applicator and is designed to allow for dose compensation in the sagittal direction and a hoop-and-clamp assembly for final field shaping. By correctly designing the shape of the slit in the former and properly adjusting the components of the latter, it is possible to accomplish quite uniform shielding without causing any weight of the shielding material to rest on the patient. The slit collimation system has a specially shaped aperture for confining the radiation beam. The hoop-and-clamp assembly has hoops and clamps which locate shielding over the patient's body. The shielding locating clamps are adjustably movable radially with respect to the hoops. (author)

  9. Late effects of intraoperative radiation therapy on retroperitoneal tissues, intestine, and bile duct in a large animal model

    Energy Technology Data Exchange (ETDEWEB)

    Sindelar, W.F.; Tepper, J.E.; Kinslla, T.J.; Barnes, M.; DeLuca, A.M.; Terrill, R.; Matthews, D.; Johnstone, P.A.S. [National Institutes of Health, Bethesda, MD (United States); Anderson, W.J. [Terre Haute Center for Medical Education, IN (United States); Bollinger, B.K. [National Naval Medical Center, Bethesda, MD (United States)

    1994-07-01

    The late histopathological effects of intraoperative radiotherapy (IORT) on retroperitoneal tissues, intestine, and bile duct were investigated in dogs. Fourteen adult foxhounds were subjected to laparotomy and varying doses (0-45 Gy) of IORT (11 MeV electrons) delivered to retroperitoneal tissues including the great vessels and ureters, to a loop of defunctionalized small bowel, or to the extrahepatic bile duct. One control animal received an aortic transection and reanastomosis at the time of laparotomy; another control received laparotomy alone. This paper describes the late effects of single-fraction IORT occurring 3-5 years following treatment. Dogs receiving IORT to the retroperitoneum through a 4 X 15 cm portal showed few gross or histologic abnormalities at 20 Gy. At doses ranging from 30-45 Gy, radiation changes in normal tissues were consistently observed. Retroperitoneal fibrosis with encasement of the ureters and great vessels developed at doses {ge}30 Gy. Radiation changes were present in the aorta and vena cava at doses {ge}40 Gy. A 30 Gy dog developed an in-field malignant osteosarcoma at 3 years which invaded the vertebral column and compressed the spinal cord. A 40 Gy animal developed obstruction of the right ureter with fatal septic hydronephrosis at 4 years. Animals receiving IORT through a 5 cm IORT portal to an upper abdominal field which included a defunctionalized loop of small bowel, showed few gross or histologic abnormalities at a dose of 20 Gy. At 30 Gy, hyaline degeneration of the intestinal muscularis layer of the bowel occurred. At a dose of 45 Gy, internal intestinal fistulae developed. One 30 Gy animal developed right ureteral obstruction and hydronephrosis at 5 years. A dog receiving 30 Gy IORT through a 5 cm portal to the extrahepatic bile duct showed diffuse fibrosis through the gastroduodenal ligament. These canine studies contribute to the area of late tissue tolerance to IORT. 7 refs., 3 figs., 5 tabs.

  10. Late effects of intraoperative radiation therapy on retroperitoneal tissues, intestine, and bile duct in a large animal model

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.E.; Kinslla, T.J.; Barnes, M.; DeLuca, A.M.; Terrill, R.; Matthews, D.; Johnstone, P.A.S.; Anderson, W.J.; Bollinger, B.K.

    1994-01-01

    The late histopathological effects of intraoperative radiotherapy (IORT) on retroperitoneal tissues, intestine, and bile duct were investigated in dogs. Fourteen adult foxhounds were subjected to laparotomy and varying doses (0-45 Gy) of IORT (11 MeV electrons) delivered to retroperitoneal tissues including the great vessels and ureters, to a loop of defunctionalized small bowel, or to the extrahepatic bile duct. One control animal received an aortic transection and reanastomosis at the time of laparotomy; another control received laparotomy alone. This paper describes the late effects of single-fraction IORT occurring 3-5 years following treatment. Dogs receiving IORT to the retroperitoneum through a 4 X 15 cm portal showed few gross or histologic abnormalities at 20 Gy. At doses ranging from 30-45 Gy, radiation changes in normal tissues were consistently observed. Retroperitoneal fibrosis with encasement of the ureters and great vessels developed at doses ≥30 Gy. Radiation changes were present in the aorta and vena cava at doses ≥40 Gy. A 30 Gy dog developed an in-field malignant osteosarcoma at 3 years which invaded the vertebral column and compressed the spinal cord. A 40 Gy animal developed obstruction of the right ureter with fatal septic hydronephrosis at 4 years. Animals receiving IORT through a 5 cm IORT portal to an upper abdominal field which included a defunctionalized loop of small bowel, showed few gross or histologic abnormalities at a dose of 20 Gy. At 30 Gy, hyaline degeneration of the intestinal muscularis layer of the bowel occurred. At a dose of 45 Gy, internal intestinal fistulae developed. One 30 Gy animal developed right ureteral obstruction and hydronephrosis at 5 years. A dog receiving 30 Gy IORT through a 5 cm portal to the extrahepatic bile duct showed diffuse fibrosis through the gastroduodenal ligament. These canine studies contribute to the area of late tissue tolerance to IORT. 7 refs., 3 figs., 5 tabs

  11. Patterns of Failure and Local Control After Intraoperative Electron Boost Radiotherapy to the Presacral Space in Combination with Total Mesorectal Excision in Patients with Locally Advanced Rectal Cancer

    International Nuclear Information System (INIS)

    Roeder, Falk; Treiber, Martina; Oertel, Susanne; Dinkel, Julien; Timke, Carmen; Funk, Angela; Garcia-Huttenlocher, Helena; Bischof, Marc; Weitz, Juergen; Harms, Wolfgang; Hensley, Frank W.; Buchler, Markus W.; Debus, Juergen; Krempien, Robert

    2007-01-01

    Purpose: To evaluate local control and patterns of failure in patients treated with intraoperative electron beam radiotherapy (IOERT) after total mesorectal excision (TME), to appraise the effectiveness of intraoperative target definition. Methods and Materials: We analyzed the outcome of 243 patients with rectal cancer treated with IOERT (median dose, 10 Gy) after TME. Eighty-eight patients received neoadjuvant and 122 patients adjuvant external beam radiotherapy (EBRT) (median dose, 41.4 Gy), and in 88% simultaneous chemotherapy was applied. Median follow-up was 59 months. Results: Local failure was observed in 17 patients (7%), resulting in a 5-year local control rate of 92%. Only complete resection and absence of nodal involvement correlated positively with local control. Considering IOERT fields, seven infield recurrences were seen in the presacral space, resulting in a 5-year local control rate of 97%. The remaining local relapses were located as follows: retrovesical/retroprostatic (5), anastomotic site (2), promontorium (1), ileocecal (1), and perineal (1). Conclusion: Intraoperative electron beam radiotherapy as part of a multimodal treatment approach including TME is a highly effective regimen to prevent local failure. The presacral space remains the site of highest risk for local failure, but IOERT can decrease the percentage of relapses in this area

  12. Intraoperative electrocorticography

    Directory of Open Access Journals (Sweden)

    Gabriela Alcaraz

    2017-01-01

    Full Text Available Intraoperative electrocorticography (ECoG is the recording of electrophysiological activity from electrodes placed directly on the exposed surface of brain, during surgery for epilepsy and tumor resection. The ECoG is helpful in defining the seizure onset and spread within the cortical surface and delineation of the interface between epileptogenic zones and functional cortex substance of the brain. Intraoperative ECoG is an invasive procedure, it is performed during surgery mostly commonly during awake craniotomy but at times during general anaesthesia. As most anesthetic agents will affect ECoG, they should be minimized or stopped prior to any recording. Activation of intraoperative epileptiform activity may also be required if there are no spontaneous discharges. The appropriate management of the anesthetic during the time of ECoG is critical for its success. There are limitations and some controversies to all the uses of intraoperative ECoG, thus each center will set their own indications, criteria, and protocols.

  13. Intra-operative radiotherapy of malignant tumors: Past, present and perspectives

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Le Bourgeois, J.P.; Ganem, G.

    1986-01-01

    Intra-operative radiotherapy consists of electron or photon radiation which is used during the operative procedure. The treatment field is arranged very precisely after critical organs have been previously arranged out of the field. The target volume includes the remaining tumor which could not be removed surgically, and the surrounding tumor bed which is also felt to be high risk for recurrence. It is preferable to have as little tumor remaining as possible before the intra-operative treatment radiation is given. Intra-operative radiotherapy was developed less than a quarter century ago in Japon, and it was later used in U.S.A. The accumulated experience in Japan and U.S.A. is rewieved here. Intra-operative radiotherapy has only recently been introduced to France. The biology, physics and medical and technical problems of intra-operative therapy are discussed [fr

  14. SU-F-T-654: Pacemaker Dose Estimate Using Optically Stimulated Luminescent Dosimeter for Left Breast Intraoperative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y; Goenka, A; Sharma, A; Wang, L; Cao, Y; Jamshidi, A [Northwell Health, Lake Success, NY (United States)

    2016-06-15

    Purpose: To assess and report the in vivo dose for a patient with a pacemaker being treated in left breast intraoperative radiation therapy (IORT). The ZEISS Intrabeam 50 kVp X-ray beam with a spherical applicator was used. Methods: The optically stimulated luminescent dosimeters (OSLDs) (Landauer nanoDots) were employed and calibrated under the conditions of the Intrabeam 50 kVp X-rays. The nanoDots were placed on the patient at approximately 15 cm away from the lumpectomy cavity both under and above a shield of lead equivalence 0.25 mm (RayShield X-Drape D-110) covering the pacemaker area during IORT with a 5 cm spherical applicator. Results: The skin surface dose near the pacemaker during the IORT with a prescription of 20 Gy was measured as 4.0±0.8 cGy. The dose behind the shield was 0.06±0.01 Gy, demonstrating more than 98% dose reduction. The in vivo skin surface doses during a typical breast IORT at a 4.5 cm spherical applicator surface were further measured at 5, 10, 15, and 20 cm away to be 159±11 cGy, 15±1 cGy, 6.6±0.5 cGy, and 1.8±0.1 cGy, respectively. A power law fit to the dose versus the distance z from the applicator surface yields the dose fall off at the skin surface following z^-2.5, which can be used to estimate skin doses in future cases. The comparison to an extrapolation of depth dose in water reveals an underestimate of far field dose using the manufactory provided data. Conclusion: The study suggests the appropriateness of OSLD as an in vivo skin dosimeter in IORT using the Intrabeam system in a wide dose range. The pacemaker dose measured during the left breast IORT was within a safe limit.

  15. Radical surgical resection and high-dose intraoperative radiation therapy (HDR-IORT) in patients with recurrent gynecologic cancers

    International Nuclear Information System (INIS)

    Gemignani, Mary L.; Alektiar, Kaled M.; Leitao, Mario; Mychalczak, Boris; Chi, Dennis; Venkatraman, Ennapadam; Barakat, Richard R.; Curtin, John P.

    2001-01-01

    Objective: To determine the outcome for patients with recurrent gynecologic tumors treated with radical resection and combined high-dose intraoperative radiation therapy (HDR-IORT). Methods and Materials: Between November 1993 and June 1998, 17 patients with recurrent gynecologic malignancies underwent radical surgical resection and high-dose-rate brachytherapy. The mean age of the study group was 49 years (range 28-72 years). The site of the primary tumor was the cervix in 9 (53%) patients, the uterus in 7 (41%) patients, and the vagina in 1 (6%) patient. The treatment for the primary disease was surgery with or without adjuvant radiation in 14 (82%) patients and definitive radiation in 3 (18%) patients. The current surgery consisted of exenterative surgery in 10 (59%) patients and tumor resection in 7 (41%) patients. Complete gross resection was achieved in 13 (76%) patients. The mean HDR-IORT dose was 14 Gy (range 12-15). Additional radiation in the form of permanent Iodine-125 implant was given to 3 of 4 patients with gross residual disease. The median peripheral dose was 140 Gy. Results: With a median follow-up of 20 months (range 3-65 months), the 3-year actuarial local control (LC) rate was 67%. In patients with complete gross resection, the 3-year LC rate was 83%, compared to 25% in patients with gross residual disease, p<0.01. The 3-year distant metastasis disease-free and overall survival rates were 54% and 54%, respectively. The complications were as follows: gastrointestinal obstruction, 4 (24%); wound complications, 4 (24%); abscesses, 3 (18%); peripheral neuropathy, 3 (18%); rectovaginal fistula, 2 (12%); and ureteral obstruction, 2 (12%). Conclusion: Radical surgical resection and combined IORT for patients with recurrent gynecologic tumors seems to provide a reasonable local-control rate in patients who have failed prior surgery and/or definitive radiation. Patient selection is very important, however, as only those patients with complete gross

  16. Arch therapy clinical case of electrons

    International Nuclear Information System (INIS)

    Larrinaga Cortina, Eduardo Francisco; Rodriguez Velorio, Ceferina; Alonso Samper, Jose Luis

    2009-01-01

    From 1998 to 2006, the Ministry of Public Health of the Republic of Cuba maintained a balanced collaboration with the Social Security Fund (CCSS) of the Republic of Costa Rica with the objective of providing professional services in radiotherapy. As part of the Cuban mission in the 2003-2005 period was conducted clinic design and implementation of a dynamic rotational technique with electron beams for treatment of a neoplastic lesion from the neuro ectoderm early in the first linear accelerator belonging to the CCSS and installed in Hospital Mexico, San Jose. The objective was to achieve locoregional control of the lesion by treatment Radiant surgical bed in the chest wall. We discuss different options settings for the treatment values arch therapy the best choice taking into account the cylindrical geometry of the treatment area and the superficiality of its location. For the determination of the absolute dose used Khan's recommendations. Treatment planning was done following the methodology suggested by Podgorsak et al. We performed a quality control of patient-specific planning and dosimetry in anthropomorphic dummy radiographic, resulting in isodose distribution of very good uniformity in the area of clinical interest. The electron arch therapy technique proved to be superior to alternative proposals for the treatment of superficial lesions with cylindrical symmetry frankly, with regard to dose homogeneity in the target volume and lower dose in critical organs. (author)

  17. Intraoperative radiation therapy in early breast cancer using a linear accelerator outside of the operative suite: an "image-guided" approach.

    Science.gov (United States)

    Hanna, Samir Abdallah; de Barros, Alfredo Carlos Simões Dornellas; de Andrade, Felipe Eduardo Martins; Bevilacqua, Jose Luiz Barbosa; Piato, José Roberto Morales; Pelosi, Edilson Lopes; Martella, Eduardo; da Silva, João Luis Fernandes; Carvalho, Heloisa de Andrade

    2014-08-01

    To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was repositioned in 39.9% of cases. No infection or anesthesia complications were observed. Local control with IORT was adequate, with low complication rates and good cosmetic outcomes. More than one-third of patients benefited from the "image-guidance" approach, and almost 40% benefited from the option of higher electron beam energies. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Auger Electron Therapy And Brachytherapy Tumor Treatment

    International Nuclear Information System (INIS)

    Laster, B.H.; Shani, G.

    2002-01-01

    Auger Electron Therapy (AET) is a binary approach for improving cancer radiotherapy. It involves the selective targeting of an atom to tumor cells using physiological pathway. The atom is then irradiated by a specific radiation that produces secondary radiation called Auger electrons. One of the problems associated with the clinical application of AET, is that the energy of the photons required for stimulating photoelectric absorption in most of the available high Z target atoms, is too low to achieve penetration through normal surrounding tissues to the depth of the tumor, when an external source is used. The solution is therefore the use of a brachytherapy technique. There are two other problems associated with the use of radiation as a cancer treatment. The first is the limitation on radiation dose to the normal tissue within the treatment volume. The second problem is the limitation imposed by the miniscule size of the critical target of the cell, namely the DNA (0.25% of the cell mass). The solution to the first problem can be achieved by using the brachytherapy technique. The second problem can be resolved by placing the radiation source in close position to the DNA. AET, as we apply it, provides the two solutions to the two problems. When a photon is absorbed by an electron in the K or L shell of an high Z atom, the electron is ejected from the atom, creating a vacancy in the shell. This vacancy is immediately filled with an electron from an upper shell. The energy difference between the two shells is sometimes emitted as an x-ray, however, frequently the energy is transferred to an outer shell electron that is emitted as an Auger electron. These electrons are emitted at energies of up to ∼30 keV and therefore have a very short range in the cell. They will deposit all their energy within 20-30 nm from the point of emission. i.e. all the energy is deposited in the DNA. In our work indium is used as the high Z atom

  19. In vivo dosimetry in intraoperative electron radiotherapy: microMOSFETs, radiochromic films and a general-purpose linac.

    Science.gov (United States)

    López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Morillo-Macías, Virginia; de Marco-Blancas, Noelia; Santos-Serra, Agustín; Quirós-Higueras, Juan David; Ferrer-Albiach, Carlos

    2014-10-01

    In vivo dosimetry is desirable for the verification, recording, and eventual correction of treatment in intraoperative electron radiotherapy (IOERT). Our aim is to share our experience of metal oxide semiconductor field-effect transistors (MOSFETs) and radiochromic films with patients undergoing IOERT using a general-purpose linac. We used MOSFETs inserted into sterile bronchus catheters and radiochromic films that were cut, digitized, and sterilized by means of gas plasma. In all, 59 measurements were taken from 27 patients involving 15 primary tumors (seven breast and eight non-breast tumors) and 12 relapses. Data were subjected to an outliers' analysis and classified according to their compatibility with the relevant doses. Associations were sought regarding the type of detector, breast and non-breast irradiation, and the radiation oncologist's assessment of the difficulty of detector placement. At the same time, 19 measurements were carried out at the tumor bed with both detectors. MOSFET measurements ([Formula: see text]  = 93.5 %, sD  =  6.5 %) were not significantly shifted from film measurements ([Formula: see text]  =  96.0 %, sD  =  5.5 %; p  =  0.109), and no associations were found (p = 0.526, p = 0.295,  and p = 0.501, respectively). As regards measurements performed at the tumor bed with both detectors, MOSFET measurements ([Formula: see text]  =  95.0 %, sD  =  5.4 % were not significantly shifted from film measurements ([Formula: see text]  =  96.4 %, sD  =  5.0 %; p  =  0.363). In vivo dosimetry can produce satisfactory results at every studied location with a general-purpose linac. Detector choice should depend on user factors, not on the detector performance itself. Surgical team collaboration is crucial to success.

  20. Tolerance of bile duct to intraoperative irradiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.

    1982-01-01

    In order to determine the effects of intraoperative radiation therapy of the bile duct and surrounding tissues, seven adult dogs were subjected to laparotomy and intraoperative irradiation with 11 MeV electrons. Two animals were treated at each dose level of 2000, 3000, and 4500 rads. A single dog which received a laparotomy and sham irradiation served as a control. The irradiation field consisted of a 5 cm diameter circle encompassing the extrahepatic bile duct, portal vein, hepatic artery, and lateral duodenal wall. The animals were followed clinically for mor than 18 months after treatment, and autopsies were performed on dogs that died to assess radiation-induced complications or tissue damage. All dogs developed fibrosis and mural thickening of the common duct, which appeared by 6 weeks following irradiation and which was dose-related, being mild at low doses and more severe at high doses. Hepatic changes were seen as early as 6 weeks after irradiation, consisting of periportal inflammation and fibrosis. The hepatic changes appeared earliest at the highest doses. Frank biliary cirrhosis eventually developed at all dose levels. Duodenal fibrosis appeared in the irradiation portal, being most severe at the highest doses and in some animals resulting in duodenal obstruction. No changes were observed in irradiated portions of portal vein and hepatic artery at any dose level. It was concluded that intraoperative radiation therapy delivered to the region of the common duct leads to ductal fibrosis, partial biliary obstruction with secondary hepatic changes, and duodenal fibrosis if bowel wall is included in the field. Clinical use of intraoperative radiation therapy to the bile duct in humans may require routine use of biliary and duodenal bypass to prevent obstructive complications

  1. Intraoperative validation of CT-based lymph nodal levels, sublevels IIa and IIb: Is it of clinical relevance in selective radiation therapy?

    International Nuclear Information System (INIS)

    Levendag, Peter; Gregoire, Vincent; Hamoir, Marc; Voet, Peter; Est, Henrie van der; Heijmen, Ben; Kerrebijn, Jeroen

    2005-01-01

    Purpose: The objectives of this study are to discuss the intraoperative validation of CT-based boundaries of lymph nodal levels in the neck, and in particular the clinical relevance of the delineation of sublevels IIa and IIb in case of selective radiation therapy (RT). Methods and Materials: To validate the radiologically defined level contours, clips were positioned intraoperatively at the level boundaries defined by surgical anatomy. In 10 consecutive patients, clips were placed, at the time of a neck dissection being performed, at the most cranial border of the neck. Anterior-posterior and lateral X-ray films were obtained intraoperatively. Next, in 3 patients, neck levels were contoured on preoperative contrast-enhanced CT scans according to the international consensus guidelines. From each of these 3 patients, an intraoperative CT scan was also obtained, with clips placed at the surgical-anatomy-based level boundaries. The preoperative (CT-based) and intraoperative (surgery-defined) CT scans were matched. Results: Clips placed at the most cranial part of the neck lined up at the caudal part of the transverse process of the cervical vertebra C-I. The posterior border of surgical level IIa (spinal accessory nerve [SAN]) did not match with the posterior border of CT-based level IIa (internal jugular vein [IJV]). Other surgical boundaries and CT-based contours were in good agreement. Conclusions: The cranial border of the neck, i.e., the cranial border of level IIa/IIb, corresponds to the caudal edge of the lateral process of C-I. Except for the posterior border between level IIa and level IIb, a perfect match was observed between the other surgical-clip-identified levels II-V boundaries (surgical-anatomy) and the CT-based delineation contours. It is argued that (1) because of the parotid gland overlapping part of level II, and (2) the frequent infestation of occult metastatic cells in the lymph channels around the IJV, the division of level II into radiologic

  2. Psychological consideration in patients with cerebral gliomas candidates for intra-operative radiation therapy based on tumor location.

    Science.gov (United States)

    Seddighi, Afsoun; Akbari, Mohammad Esmaeil; Seddighi, Amir Saied; Nikouei, Amir

    2017-01-01

    Intra-operative Radiation Therapy (IORT) is gaining popularity as an adjuvant option to surgical resection, in treatment of glioblastoma multiforme (GBM) for increasing survival rate, which a highly aggressive cerebral tumor with poor prognosis. Τhe authors plan to investigate the effects of IORT combined with surgical resection on the psychological status of these patients based on tumor location. From December 2013 to February 2017, we have enrolled 109 patients with high grade cerebral gliomas, documented by Magnetic Resonance Spectroscopy (MRS). Patients with previous history of brain surgery or radiation, altered mental status and psychological content and patients diagnosed with metastases were excluded. Demographic data, tumor volume based on pre-operative Magnetic Resonance Imaging (MRI) and psychological status were recorded based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria. The remaining 56 patients, were equally randomized into conventional (surgical resection-group A), and trial (surgical resection with IORT-group B) who underwent IORT using the 50kV INTRABEAM® system (Carl Zeiss Meditec AG, Germany). Psychological profiles of both groups were re-evaluated in the 3 rd post-operative month. Group A consisted of 18 males and 10 females with mean age of 54.4 years, while group B consisted of 16 males and 12 females with mean age of 57.8 years. Tumor volumetry revealed mean 81.52cc and 82.8cc for group A and B respectively. (P value 0.14) Patients were classified based on glioma location on pre-operative MRI: a) left parietal lobe (6 in group A, 5 in group B); b) left temporal lobe (7 in group A, 5 in group B); c) right parietal lobe (5 in group A, 6 in group B); d) left fronto-temporal lobe (4 in group A, 6 in group B); e) left parieto-temporal lobe (4 in group A, 5 in group B); and, f) right frontal lobe (2 in group A, 1 in group B). Group B received mean 8.05 Gy radiation for mean 11.2 minutes. Post

  3. Clinical phase I/II trial to investigate neoadjuvant intensity-modulated short term radiation therapy (5 × 5 gy) and intraoperative radiation therapy (15 gy) in patients with primarily resectable pancreatic cancer - NEOPANC

    International Nuclear Information System (INIS)

    Roeder, Falk; Debus, Juergen; Huber, Peter E; Werner, Jens; Timke, Carmen; Saleh-Ebrahimi, Ladan; Schneider, Lutz; Hackert, Thilo; Hartwig, Werner; Kopp-Schneider, Annette; Hensley, Frank W; Buechler, Markus W

    2012-01-01

    The current standard treatment, at least in Europe, for patients with primarily resectable tumors, consists of surgery followed by adjuvant chemotherapy. But even in this prognostic favourable group, long term survival is disappointing because of high local and distant failure rates. Postoperative chemoradiation has shown improved local control and overalls survival compared to surgery alone but the value of additional radiation has been questioned in case of adjuvant chemotherapy. However, there remains a strong rationale for the addition of radiation therapy considering the high rates of microscopically incomplete resections after surgery. As postoperative administration of radiation therapy has some general disadvantages, neoadjuvant and intraoperative approaches theoretically offer benefits in terms of dose escalation, reduction of toxicity and patients comfort especially if hypofractionated regimens with highly conformal techniques like intensity-modulated radiation therapy are considered. The NEOPANC trial is a prospective, one armed, single center phase I/II study investigating a combination of neoadjuvant short course intensity-modulated radiation therapy (5 × 5 Gy) in combination with surgery and intraoperative radiation therapy (15 Gy), followed by adjuvant chemotherapy according to the german treatment guidelines, in patients with primarily resectable pancreatic cancer. The aim of accrual is 46 patients. The primary objectives of the NEOPANC trial are to evaluate the general feasibility of this approach and the local recurrence rate after one year. Secondary endpoints are progression-free survival, overall survival, acute and late toxicity, postoperative morbidity and mortality and quality of life. http://www.clinicaltrials.gov/ct2/show/NCT01372735

  4. Precision IORT - Image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction.

    Science.gov (United States)

    Schneider, Frank; Bludau, Frederic; Clausen, Sven; Fleckenstein, Jens; Obertacke, Udo; Wenz, Frederik

    2017-05-01

    To the present date, IORT has been eye and hand guided without treatment planning and tissue heterogeneity correction. This limits the precision of the application and the precise documentation of the location and the deposited dose in the tissue. Here we present a set-up where we use image guidance by intraoperative cone beam computed tomography (CBCT) for precise online Monte Carlo treatment planning including tissue heterogeneity correction. An IORT was performed during balloon kyphoplasty using a dedicated Needle Applicator. An intraoperative CBCT was registered with a pre-op CT. Treatment planning was performed in Radiance using a hybrid Monte Carlo algorithm simulating dose in homogeneous (MCwater) and heterogeneous medium (MChet). Dose distributions on CBCT and pre-op CT were compared with each other. Spinal cord and the metastasis doses were evaluated. The MCwater calculations showed a spherical dose distribution as expected. The minimum target dose for the MChet simulations on pre-op CT was increased by 40% while the maximum spinal cord dose was decreased by 35%. Due to the artefacts on the CBCT the comparison between MChet simulations on CBCT and pre-op CT showed differences up to 50% in dose. igIORT and online treatment planning improves the accuracy of IORT. However, the current set-up is limited by CT artefacts. Fusing an intraoperative CBCT with a pre-op CT allows the combination of an accurate dose calculation with the knowledge of the correct source/applicator position. This method can be also used for pre-operative treatment planning followed by image guided surgery. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Experimental and clinical studies with intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Kinsella, T.; Tepper, J.; Travis, E.L.; Rosenberg, S.A.; Glatstein, E.

    1983-01-01

    Studies of normal tissue tolerance to intraoperative radiotherapy were done upon 65 dogs subjected to laparotomy and 11 million electron volt electron irradiation in doses ranging from zero to 5,000 rads. Results of studies indicated that intact aorta and vena cava tolerate up to 5,000 rads without loss of structural integrity. Ureteral fibrosis and stenosis develop at doses of 3,000 rads or more. Arterial anastomoses heal after doses of 4,500 rads, but fibrosis can lead to occlusion. Intestinal suture lines heal after doses of 4,500 rads. Bile duct fibrosis and stenosis develop at doses of 2,000 rads or more. Biliary-enteric anastomoses fail to heal at any dose level. A clinical trial of intraoperative radiotherapy combined with radical surgery was performed upon 20 patients with advanced malignant tumors which were considered unlikely to be cured by conventional therapies and which included carcinomas of the stomach, carcinomas of the pancreas, carcinomas involving the hilus of the liver, retroperitoneal sarcomas and osteosarcomas of the pelvis. All patients underwent resection of gross tumor, followed by intraoperative irradiation of the tumor bed and regional nodal basins. Some patients received additional postoperative external beam radiotherapy. Treatment mortality for combined operation and radiotherapy occurred in four of 20 patients. Postoperative complications occurred in four of the 16 surviving patients. Local tumor control was achieved in 11 of the 16 surviving patients, with an over-all median follow-up period of 18 months. The clinical trial suggested that intraoperative radiotherapy is a feasible adjunct to resection in locally advanced tumors, that the resulting mortality and morbidity is similar to that expected from operation alone and that local tumor control may be improved

  6. Moving strip technique of electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Wakasa, Hiroyuki; Oguri, Nobuhiro; Kitayama, Takuichi; Nakagiri, Yoshitada; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1984-12-01

    The fieldsize in electron beam therapy is determined by the cone size. In case of skin metastasis of a malignant tumor and so on, which need a large field size and whose area is much larger than the size of the cone, a large field size is usually produced by dividing the portals. However, the dose distribution at the border of the field becomes unequal, and hot and cold dose areas are produced according to the distance between portals. We tried the strip field technique in a large field along the long axis of the body in order to flatten the dose of the border employing the moving strip used for whole abdominal irradiation in ovarian cancer. We set the film in Mix-DP and used the strip field technique with 2.5cm steps. We discussed the relationship between the interval (distance between portals) and the flattening of the dose within the field. Skin movement due to breathing and influences on the flattening of the dose were considered. The proper flatness was obtained at depths of 0,1,2, and 3cm by setting the interval at 0.5cm. When skin movement was produced by breathing in +-1.5mm, the proper flaness was obtained also at a 0.5-cm interval. It seems that smoothing is increased by breathing. An ''electron beam moving strip'' with a 2.5-cm step and 0.5-cm interval was clinically effective in the treatment of patients with skin metastasis of colon cancer. (author).

  7. Radiotherapy for ocular lesions by electron beam therapy

    International Nuclear Information System (INIS)

    Miyaishi, Kazuo

    1981-01-01

    Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The appliance of conventional X ray therapy has been gradually abandaned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973; It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, 4000 - 5000 rads in total is applied by 8 MeV electron twice a week method. 3) For orbitar lymphoid neoplasm, Cobalt-60 γ ray or Linac X ray is applied together with electron beam. 4) For embryonal rhabdomyosarcoma, adenoid cystic cancer etc., the therapy for whole body is necessary. 5) For benign tumors, a small dose at a time is applied for a long time. (author)

  8. Photon and electron collimator effects on electron output and abutting segments in energy modulated electron therapy

    International Nuclear Information System (INIS)

    Olofsson, Lennart; Karlsson, Magnus G.; Karlsson, Mikael

    2005-01-01

    In energy modulated electron therapy a large fraction of the segments will be arranged as abutting segments where inhomogeneities in segment matching regions must be kept as small as possible. Furthermore, the output variation between different segments should be minimized and must in all cases be well predicted. For electron therapy with add-on collimators, both the electron MLC (eMLC) and the photon MLC (xMLC) contribute to these effects when an xMLC tracking technique is utilized to reduce the x-ray induced leakage. Two add-on electron collimator geometries have been analyzed using Monte Carlo simulations: One isocentric eMLC geometry with an isocentric clearance of 35 cm and air or helium in the treatment head, and one conventional proximity geometry with a clearance of 5 cm and air in the treatment head. The electron fluence output for 22.5 MeV electrons is not significantly affected by the xMLC if the shielding margins are larger than 2-3 cm. For small field sizes and 9.6 MeV electrons, the isocentric design with helium in the treatment head or shielding margins larger than 3 cm is needed to avoid a reduced electron output. Dose inhomogeneity in the matching region of electron segments is, in general, small when collimator positions are adjusted to account for divergence in the field. The effect of xMLC tracking on the electron output can be made negligible while still obtaining a substantially reduced x-ray leakage contribution. Collimator scattering effects do not interfere significantly when abutting beam techniques are properly applied

  9. SU-E-T-537: Comparison of Intra-Operative Soft X-Rays to Low Energy Electron Beams for Treatment of Superficial Lesions

    International Nuclear Information System (INIS)

    Chinsky, B; Diak, A; Gros, S; Sethi

    2014-01-01

    Purpose: Superficial soft x-ray applicators have recently been designed for use with existing intra-operative radiotherapy systems. These applicators may be used in treating superficial lesions which are conventionally treated with electron beams. The purpose of this abstract is to compare dose distributions of an intra-operative 50kV x-ray unit with low energy electrons for the treatment of superficial lesions. Methods: Dosimetric parameters for 1 and 3-cm diameter Intrabeam superficial x-ray applicators were measured with EBT3 Gafchromic film in a solid water phantom. Depth dose distributions and profiles (d=2, 5, 10 and 15mm) were obtained by prescribing a dose of 400cGy at 5mm depth below the phantom surface. Corresponding dose profiles for 6-MeV electrons were acquired from a Varian Clinac 21EX at 100 SSD. H and D calibration curves were generated for each modality for 0-800cGy. Results: Dose coverage, penumbra, dose uniformity, surface dose, and dose fall-off were examined. Compared to electrons, Intrabeam lateral dose coverage at 5mm depth was 70% larger with a much sharper (1/4) penumbra. Electron isodose levels bulged with depth, whereas Intrabeam isodose levels exhibited a convex cone shape. The Intrabeam dose profiles demonstrated horns in the dose distribution up to a 5mm depth and an exponential dose fall-off. Relative surface dose was higher for the Intrabeam applicators. Treatment times were comparable for both modalities. Conclusions: The very small penumbra of Intrabeam at shallow depths could be useful in treating superficial lesions adjacent to critical structures. The exponential dose fall-off of Intrabeam makes it appealing in the sparing of structures beyond the lesion. However, for lesions past a depth of 5mm, electrons would be desirable as they penetrate farther and provide skin sparing. Intrabeam may be preferable for sites that are difficult to treat with electrons due to mechanical and physical limitations

  10. The short and long term effects of intraoperative electron beam radiotherapy (IORT) on thoracic organs after pneumonectomy an experimental study in the canine model

    International Nuclear Information System (INIS)

    Boer, Willem J. de; Mehta, Dinesh M.; Timens, Wim; Hoekstra, Harald J.

    1999-01-01

    Purpose: The tolerance of mediastinal structures and thoracic organs to intraoperative radiotherapy (IORT) was investigated in the canine model. Methods and Materials: Twenty-two adult beagles divided into three groups were subjected to a left pneumonectomy and IORT (10 MeV electrons) at doses of 20 Gy (n = 9), 25 Gy (n = 4), or 30 Gy (n = 9). Intraoperative electron beam radiotherapy was delivered through a 5 cm circular lucite cone encompassing a mediastinal field including the bronchial stump, aorta, esophagus, heart, phrenic nerve, contralateral hilar structures, and lung. Clinical monitoring was performed with regular chest X-ray, ECG, bronchoscopy, esofagoscopy, and fluoroscopy. From the different treatment dose groups, dogs were electively sacrificed at 1.5, 6, 12, and 72 months with complete autopsies. Results: There was no bronchial stump dehiscence or acute morbidity. Four dogs developed radiation induced esophagitis (18%), one in the 20 Gy IORT group (11%) and three in the 30 Gy IORT group (33%). There were six IORT related mortalities (27.5%), one esophagoaortic fistula (4.5%) and five bronchovascular fistulas (23%): two in the 20 Gy IORT group (22%), two in the 25 Gy IORT group (50%) and two in the 30 Gy IORT group (22%). Histopathological findings in uncomplicated follow-up showed marked myointimal fibrosis in the muscular arteries, submucosal fibrosis of the esophagus, and interstitial fibrosis of bronchial and lung tissue, especially in the higher dose group. Conclusion: The mediastinal vascular, bronchial and esophageal structures are relatively sensitive to doses > 20Gy IORT. The IORT related morbidity found in this study may be lower when the current clinically used IORT doses of 10-15 Gy are applied. Further clinical application of IORT in the future treatment strategies for resectable non small cell lung cancer may be worthwhile to investigate

  11. Electron dose rate and photon contamination in electron arc therapy

    International Nuclear Information System (INIS)

    Pla, M.; Podgorsak, E.B.; Pla, C.

    1989-01-01

    The electron dose rate at the depth of dose maximum dmax and the photon contamination are discussed as a function of several parameters of the rotational electron beam. A pseudoarc technique with an angular increment of 10 degrees and a constant number of monitor units per each stationary electron field was used in our experiments. The electron dose rate is defined as the electron dose at a given point in phantom divided by the number of monitor units given for any one stationary electron beam. For a given depth of isocenter di the electron dose rates at dmax are linearly dependent on the nominal field width w, while for a given w the dose rates are inversely proportional to di. The dose rates for rotational electron beams with different di are related through the inverse square law provided that the two beams have (di,w) combinations which give the same characteristic angle beta. The photon dose at the isocenter depends on the arc angle alpha, field width w, and isocenter depth di. For constant w and di the photon dose at isocenter is proportional to alpha, for constant alpha and w it is proportional to di, and for constant alpha and di it is inversely proportional to w. The w and di dependence implies that for the same alpha the photon dose at the isocenter is inversely proportional to the electron dose rate at dmax

  12. Breast conserving surgery in combination with intraoperative radiotherapy after previous external beam therapy: an option to avoid mastectomy.

    Science.gov (United States)

    Thangarajah, F; Heilmann, J; Malter, W; Kunze, S; Marnitz, S; Mallmann, P; Wenz, F; Sperk, E

    2018-04-01

    Mastectomy is the standard procedure in patients with in-breast tumor recurrence (IBTR) or breast cancer after irradiation of the chest due to Hodgkin's disease. In certain cases a second breast conserving surgery (BCS) in combination with intraoperative radiotherapy (IORT) is possible. To date, data concerning BCS in combination with IORT in pre-irradiated patients are limited. This is the first pooled analysis of this special indication with a mature follow-up of 5 years. Patients with IBTR after external beam radiotherapy (EBRT; treated in two centers) for breast cancer were included. Patients with previous EBRT including the breast tissue due to other diseases were also included. IORT was performed with the Intrabeam™-device using low kV X-rays. Clinical data including outcome for all patients and toxicity for a representative cohort (LENT-SOMA scales) were obtained. Statistical analyses were done including Kaplan-Meier estimates for local recurrence, distant metastasis and overall survival. A total of 41 patients were identified (39 patients with IBTR, 2 with Hodgkin`s disease in previous medical history). Median follow-up was 58 months (range 4-170). No grade 3/4 acute toxicity occurred within 9 weeks. Local recurrence-free survival rate was 89.9% and overall survival was 82.7% at 5 years. Seven patients developed metastasis within the whole follow-up. BCS in combination with IORT in IBTR in pre-irradiated patients is a feasible method to avoid mastectomy with a low risk of side effects and an excellent local control and good overall survival.

  13. Cosmesis and Breast-Related Quality of Life Outcomes After Intraoperative Radiation Therapy for Early Breast Cancer: A Substudy of the TARGIT-A Trial

    Energy Technology Data Exchange (ETDEWEB)

    Corica, Tammy, E-mail: Tammy.Corica@health.wa.gov.au [Radiation Oncology Clinical Trials and Research Unit, Comprehensive Cancer Centre, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Medicine and Pharmacology, University of Western Australia, Crawley, Western Australia (Australia); Nowak, Anna K. [School of Medicine and Pharmacology, University of Western Australia, Crawley, Western Australia (Australia); Department of Medical Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); Saunders, Christobel M. [School of Surgery, University of Western Australia, Crawley, Western Australia (Australia); Department of Surgery Fiona Stanley Hospital, Western Australia (Australia); Bulsara, Max [Institute for Health Research, University of Notre Dame, Fremantle, Western Australia (Australia); Taylor, Mandy [Radiation Oncology, Comprehensive Cancer Centre, Sir Charles Gairdner Hospital Nedlands, Western Australia (Australia); Vaidya, Jayant S. [Department of Surgery, Royal Free Hospital, London (United Kingdom); Clinical Trials Group, Division of Surgery and Interventional Science, University College, London, London (United Kingdom); Department of Surgery, Whittington Health, London (United Kingdom); Baum, Michael [Clinical Trials Group, Division of Surgery and Interventional Science, University College London, London (United Kingdom); Joseph, David J. [School of Surgery, University of Western Australia, Western Australia (Australia); Genesis Cancer Care, Western Australia (Australia); Radiation Oncology, Comprehensive Cancer Centre, Sir Charles Gairdner Hospital, Western Australia (Australia)

    2016-09-01

    Purpose: To report the first comprehensive investigation of patient-reported cosmesis and breast-related quality of life (QOL) outcomes comparing patients randomized to risk-adapted single-dose intraoperative radiation therapy (TARGIT-IORT) versus external beam radiation therapy (EBRT) on the TARGIT-A trial. Methods and Materials: Longitudinal cosmesis and QOL data were collected from a subset of TARGIT-A participants who received TARGIT-IORT as a separate procedure (postpathology). Patients completed a cosmetic assessment before radiation therapy and annually thereafter for at least 5 years. Patients also completed the combined European Organization for Research and Treatment of Cancer (EORTC) core questionnaire and Breast-Specific Module in addition to the Body Image after Breast Cancer Questionnaire at baseline and annually thereafter. The combined EORTC questionnaires were also collected 3, 6, and 9 months after wide local excision. Results: An Excellent–Good cosmetic result was scored more often than a Fair–Poor result for both treatment groups across all time points. The TARGIT-IORT patients reported better breast-related QOL than EBRT patients. Statistically and clinically significant differences were seen at month 6 and year 1, with EBRT patients having moderately worse breast symptoms (a statistically significant difference of more than 10 in a 100-point scale) than TARGIT-IORT patients at these time points. Conclusion: Patients treated with TARGIT-IORT on the TARGIT-A trial have similar self-reported cosmetic outcome but better breast-related QOL outcomes than patients treated with EBRT. This important evidence can facilitate the treatment decision-making process for patients who have early breast cancer suitable for breast-conserving surgery and inform their clinicians.

  14. Cosmesis and Breast-Related Quality of Life Outcomes After Intraoperative Radiation Therapy for Early Breast Cancer: A Substudy of the TARGIT-A Trial

    International Nuclear Information System (INIS)

    Corica, Tammy; Nowak, Anna K.; Saunders, Christobel M.; Bulsara, Max; Taylor, Mandy; Vaidya, Jayant S.; Baum, Michael; Joseph, David J.

    2016-01-01

    Purpose: To report the first comprehensive investigation of patient-reported cosmesis and breast-related quality of life (QOL) outcomes comparing patients randomized to risk-adapted single-dose intraoperative radiation therapy (TARGIT-IORT) versus external beam radiation therapy (EBRT) on the TARGIT-A trial. Methods and Materials: Longitudinal cosmesis and QOL data were collected from a subset of TARGIT-A participants who received TARGIT-IORT as a separate procedure (postpathology). Patients completed a cosmetic assessment before radiation therapy and annually thereafter for at least 5 years. Patients also completed the combined European Organization for Research and Treatment of Cancer (EORTC) core questionnaire and Breast-Specific Module in addition to the Body Image after Breast Cancer Questionnaire at baseline and annually thereafter. The combined EORTC questionnaires were also collected 3, 6, and 9 months after wide local excision. Results: An Excellent–Good cosmetic result was scored more often than a Fair–Poor result for both treatment groups across all time points. The TARGIT-IORT patients reported better breast-related QOL than EBRT patients. Statistically and clinically significant differences were seen at month 6 and year 1, with EBRT patients having moderately worse breast symptoms (a statistically significant difference of more than 10 in a 100-point scale) than TARGIT-IORT patients at these time points. Conclusion: Patients treated with TARGIT-IORT on the TARGIT-A trial have similar self-reported cosmetic outcome but better breast-related QOL outcomes than patients treated with EBRT. This important evidence can facilitate the treatment decision-making process for patients who have early breast cancer suitable for breast-conserving surgery and inform their clinicians.

  15. Radiation dermatitis following electron beam therapy

    International Nuclear Information System (INIS)

    Price, N.M.

    1978-01-01

    Ten patients, who had been treated for mycosis fungoides with electron beam radiation ten or more years previously, were examined for signs of radiation dermatitis. Although most patients had had acute radiation dermatitis, only a few manifested signs of mild chronic changes after having received between 1,000 and 2,800 rads

  16. Pre- and postoperative cellular immunology in patients treated by pancreatoduodenectomy and intraoperative radiation therapy for carcinoma of the head of the pancreas

    International Nuclear Information System (INIS)

    Komatsu, Eiji

    1993-01-01

    Purified protein derivative of tuberculin (PPD) subcutaneous reaction, phytohemagglutinin (PHA) responses, peripheral lymphocytes, and lymphocyte subsets were investigated in 21 patients with pancreatic head cancer (in stage 2: 2, stage 3: 9, stage 4: 10 according to the General Rules of the JPS) and compared with 6 patients with early gastric cancer. The percentages of cytotoxic T cells and helper T cells in the patients with stage 3 pancreatic cancer were higher than in the patients with gastric cancer, but lower in the stage 4 patients than in the stage 3 patients. The PPD subcutaneous reaction in the stage 4 patients was weaker than in the gastric cancer and stage 3 patients. The same immunological responses were monitored in 12 patients with pancreatic head cancer in the early period after pancreatoduodenectomy (PD) with or without intraoperative radiation therapy (IORT). PHA responses, lymphocyte counts and the percentages of T cells, cytotoxic T cells and helper T cells in the patients who underwent both PD and IORT were much lower than in the patients who underwent PD without IORT. These findings suggest that the level of cellular immunology in patients with stage 3 pancreatic cancer was higher than in the early gastric cancer and stage 4 patients preoperatively, but that postoperatively it had been suppressed by PD and IORT. Such suppression must be prevented to some degree to achieve a cure. The necessity of new combined modality treatment with immunotherapy may be indicated for a better prognosis. (author)

  17. Intraoperative irradiation in advanced cervical cancer

    International Nuclear Information System (INIS)

    Delgado, G.; Goldson, A.L.; Ashayeri, E.; Petrilli, E.S.

    1987-01-01

    Conventional treatment of cervical cancer, such as radical hysterectomy with lymphadenectomy or pelvic exenteration, is limited to the pelvis. Standard radio-therapeutic treatment is a combination of external-beam radiotherapy to the pelvis and intracavitary applications. However, there is a group of patients for whom external radiotherapy alone has limitations. This group consists primarily of patients with large pelvic lymph nodes containing metastatic cancer, metastatically involved paraaortic lymph nodes outside the usual pelvic radiation field, or large central tumors with parametrial involvement. In patients with cancer of the cervix, the incidence of metastasis to paraaortic lymph nodes is high. Attempts to treat paraaortic nodes with external radiotherapy have resulted in high complication rates because the treatment field includes the highly sensitive gastrointestinal tract. External radiation therapy after retroperitoneal exploration of lymph nodes does not seem to improve survival. In an attempt to circumvent the morbidity and mortality associated with conventional external-beam irradiation, the authors initiated a pilot study of intraoperative electron-beam irradiation of the paraaortic nodes and of the large metastatic lymph nodes in the pelvis. The intraoperative boost was followed by conventional fractionated external-beam irradiation. The theoretical advantages of this procedure include a higher radiation tumor dose without a concomitant increase in treatment morbidity and mortality

  18. Outcome of intraoperative goal-directed therapy using Vigileo/FloTrac in high-risk patients scheduled for major abdominal surgeries: A prospective randomized trial

    Directory of Open Access Journals (Sweden)

    Mohammed A. Elgendy

    2017-07-01

    Conclusion: The applied protocol for intraoperative GDT provided significant reduction of PO morbidities, ICU and hospital LOS but couldn‘t significantly reduce mortality rates in high risk patients scheduled for major abdominal surgeries.

  19. Outcomes in a Multi-institutional Cohort of Patients Treated With Intraoperative Radiation Therapy for Advanced or Recurrent Renal Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Paly, Jonathan J. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Hallemeier, Christopher L. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Biggs, Peter J.; Niemierko, Andrzej [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Roeder, Falk [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany); Martínez-Monge, Rafael [Radiation Oncology Division, University of Navarre, Pamplona (Spain); Whitson, Jared [Department of Urology, University of California San Francisco, San Francisco, California (United States); Calvo, Felipe A. [Departamento de Oncología, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Fastner, Gerd; Sedlmayer, Felix [Department of Radiotherapy and Radio-Oncology, Paracelsus Medical University Clinics, Salzburg (Austria); Wong, William W. [Department of Radiation Oncology, Mayo Clinic, Scottsdale, Arizona (United States); Ellis, Rodney J. [Department of Radiation Oncology, Seidman Cancer Center University Hospitals Case Medical Center, Cleveland, Ohio (United States); Haddock, Michael G.; Choo, Richard [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Shipley, William U.; Zietman, Anthony L. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Efstathiou, Jason A., E-mail: jefstathiou@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2014-03-01

    Purpose/Objective(s): This study aimed to analyze outcomes in a multi-institutional cohort of patients with advanced or recurrent renal cell carcinoma (RCC) who were treated with intraoperative radiation therapy (IORT). Methods and Materials: Between 1985 and 2010, 98 patients received IORT for advanced or locally recurrent RCC at 9 institutions. The median follow-up time for surviving patients was 3.5 years. Overall survival (OS), disease-specific survival (DSS), and disease-free survival (DFS) were estimated with the Kaplan-Meier method. Chained imputation accounted for missing data, and multivariate Cox hazards regression tested significance. Results: IORT was delivered during nephrectomy for advanced disease (28%) or during resection of locally recurrent RCC in the renal fossa (72%). Sixty-nine percent of the patients were male, and the median age was 58 years. At the time of primary resection, the T stages were as follows: 17% T1, 12% T2, 55% T3, and 16% T4. Eighty-seven percent of the patients had a visibly complete resection of tumor. Preoperative or postoperative external beam radiation therapy was administered to 27% and 35% of patients, respectively. The 5-year OS was 37% for advanced disease and 55% for locally recurrent disease. The respective 5-year DSS was 41% and 60%. The respective 5-year DFS was 39% and 52%. Initial nodal involvement (hazard ratio [HR] 2.9-3.6, P<.01), presence of sarcomatoid features (HR 3.7-6.9, P<.05), and higher IORT dose (HR 1.3, P<.001) were statistically significantly associated with decreased survival. Adjuvant systemic therapy was associated with decreased DSS (HR 2.4, P=.03). For locally recurrent tumors, positive margin status (HR 2.6, P=.01) was associated with decreased OS. Conclusions: We report the largest known cohort of patients with RCC managed by IORT and have identified several factors associated with survival. The outcomes for patients receiving IORT in the setting of local recurrence compare favorably to

  20. A Clinical phase I/II trial to investigate preoperative dose-escalated intensity-modulated radiation therapy (IMRT and intraoperative radiation therapy (IORT in patients with retroperitoneal soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Roeder Falk

    2012-07-01

    Full Text Available Abstract Background Local control rates in patients with retroperitoneal soft tissue sarcoma (RSTS remain disappointing even after gross total resection, mainly because wide margins are not achievable in the majority of patients. In contrast to extremity sarcoma, postoperative radiation therapy (RT has shown limited efficacy due to its limitations in achievable dose and coverage. Although Intraoperative Radiation Therapy (IORT has been introduced in some centers to overcome the dose limitations and resulted in increased outcome, local failure rates are still high even if considerable treatment related toxicity is accepted. As postoperative administration of RT has some general disadvantages, neoadjuvant approaches could offer benefits in terms of dose escalation, target coverage and reduction of toxicity, especially if highly conformal techniques like intensity-modulated radiation therapy (IMRT are considered. Methods/design The trial is a prospective, one armed, single center phase I/II study investigating a combination of neoadjuvant dose-escalated IMRT (50–56 Gy followed by surgery and IORT (10–12 Gy in patients with at least marginally resectable RSTS. The primary objective is the local control rate after five years. Secondary endpoints are progression-free and overall survival, acute and late toxicity, surgical resectability and patterns of failure. The aim of accrual is 37 patients in the per-protocol population. Discussion The present study evaluates combined neoadjuvant dose-escalated IMRT followed by surgery and IORT concerning its value for improved local control without markedly increased toxicity. Trial registration NCT01566123

  1. A Clinical phase I/II trial to investigate preoperative dose-escalated intensity-modulated radiation therapy (IMRT) and intraoperative radiation therapy (IORT) in patients with retroperitoneal soft tissue sarcoma

    International Nuclear Information System (INIS)

    Roeder, Falk; Hensley, Frank W; Buechler, Markus W; Debus, Juergen; Koch, Moritz; Weitz, Juergen; Bischof, Marc; Schulz-Ertner, Daniela; Nikoghosyan, Anna V; Huber, Peter E; Edler, Lutz; Habl, Gregor; Krempien, Robert; Oertel, Susanne; Saleh-Ebrahimi, Ladan

    2012-01-01

    Local control rates in patients with retroperitoneal soft tissue sarcoma (RSTS) remain disappointing even after gross total resection, mainly because wide margins are not achievable in the majority of patients. In contrast to extremity sarcoma, postoperative radiation therapy (RT) has shown limited efficacy due to its limitations in achievable dose and coverage. Although Intraoperative Radiation Therapy (IORT) has been introduced in some centers to overcome the dose limitations and resulted in increased outcome, local failure rates are still high even if considerable treatment related toxicity is accepted. As postoperative administration of RT has some general disadvantages, neoadjuvant approaches could offer benefits in terms of dose escalation, target coverage and reduction of toxicity, especially if highly conformal techniques like intensity-modulated radiation therapy (IMRT) are considered. The trial is a prospective, one armed, single center phase I/II study investigating a combination of neoadjuvant dose-escalated IMRT (50–56 Gy) followed by surgery and IORT (10–12 Gy) in patients with at least marginally resectable RSTS. The primary objective is the local control rate after five years. Secondary endpoints are progression-free and overall survival, acute and late toxicity, surgical resectability and patterns of failure. The aim of accrual is 37 patients in the per-protocol population. The present study evaluates combined neoadjuvant dose-escalated IMRT followed by surgery and IORT concerning its value for improved local control without markedly increased toxicity. NCT01566123

  2. Intraoperative Radiation Therapy Reduces Local Recurrence Rates in Patients With Microscopically Involved Circumferential Resection Margins After Resection of Locally Advanced Rectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alberda, Wijnand J.; Verhoef, Cornelis [Department of Surgery, Division of Surgical Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Nuyttens, Joost J. [Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Meerten, Esther van [Department of Medical Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Rothbarth, Joost [Department of Surgery, Division of Surgical Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Wilt, Johannes H.W. de [Department of Surgery, Division of Surgical Oncology, Radboud University Nijmegen Medical Center, Nijmegen (Netherlands); Burger, Jacobus W.A., E-mail: j.burger@erasmusmc.nl [Department of Surgery, Division of Surgical Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands)

    2014-04-01

    Purpose: Intraoperative radiation therapy (IORT) is advocated by some for patients with locally advanced rectal cancer (LARC) who have involved or narrow circumferential resection margins (CRM) after rectal surgery. This study evaluates the potentially beneficial effect of IORT on local control. Methods and Materials: All surgically treated patients with LARC treated in a tertiary referral center between 1996 and 2012 were analyzed retrospectively. The outcome in patients treated with IORT with a clear but narrow CRM (≤2 mm) or a microscopically involved CRM was compared with the outcome in patients who were not treated with IORT. Results: A total of 409 patients underwent resection of LARC, and 95 patients (23%) had a CRM ≤ 2 mm. Four patients were excluded from further analysis because of a macroscopically involved resection margin. In 43 patients with clear but narrow CRMs, there was no difference in the cumulative 5-year local recurrence-free survival of patients treated with (n=21) or without (n=22) IORT (70% vs 79%, P=.63). In 48 patients with a microscopically involved CRM, there was a significant difference in the cumulative 5-year local recurrence-free survival in favor of the patients treated with IORT (n=31) compared with patients treated without IORT (n=17) (84 vs 41%, P=.01). Multivariable analysis confirmed that IORT was independently associated with a decreased local recurrence rate (hazard ratio 0.24, 95% confidence interval 0.07-0.86). There was no significant difference in complication rate of patients treated with or without IORT (65% vs 52%, P=.18) Conclusion: The current study suggests that IORT reduces local recurrence rates in patients with LARC with a microscopically involved CRM.

  3. Intraoperative radiotherapy in combined treatment of sinonasal malignant tumors

    Science.gov (United States)

    Novikov, V. A.; Gribova, O. V.; Vasiljev, R. V.; Choynzonov, E. L.; Shtin, V. I.; Shiianova, A. A.; Surkova, P. V.; Starceva, Zh. A.; Shilova, O. G.

    2017-09-01

    Obvious advantage of IORT (intraoperative radiotherapy) is that the radiation source is delivered directly to the bed of the tumor during surgery, thus avoiding the negative impact on the skin, subcutaneous tissue and reducing the risk of fibrosis. Sinonasal tumors—a convenient object for intraoperative radiotherapy application (surface location, relatively small size tumors, good operational access). The surface location and comparatively small size of neoplasms, good operational access provide an efficient and accurate transfer of the electron beam to the postoperative cavity to increase the irradiation dose in the areas of the most probable recurrence, which makes the tumors of this localization a convenient object for the use of the intraoperative radiation therapy. The treatment was conducted using a mobile compact betatron (MIB-6E), 10-12 Gy single dose. IORT session extends surgery period by 30 min. There were no pathological clinical and laboratory reactions on IORT in the early postoperative period. Carrying out the procedure is possible in various standard operating rooms. It does not require special security measures for the patients and the staff. IORT with the help of electron beam allows avoiding post-radiation reactions and achieving a 5-year—disease-free survival of 66% of the patients. IORT session is possible through a minimal incision during organ preservation surgeries. Evident economic feasibility provides the prospects of applying IORT in the clinical practice.

  4. Clinical application of dosimetry in electron beam therapy

    International Nuclear Information System (INIS)

    Yoshiura, Takao

    1995-01-01

    In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author)

  5. WE-A-207-02: Electron Beam Therapy - Current Status and Future Directions

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q. [Duke University Medical Center (United States)

    2015-06-15

    In memory of the significant contribution of Dr. Jacques Ovadia to electron beam techniques, this session will review recent, advanced techniques which are reinvigorating the science of electron beam radiation therapy. Recent research efforts in improving both the applicability and quality of the electron beam therapy will be discussed, including modulated electron beam radiotherapy (MERT) and dynamic electron arc radiotherapy (DEAR). Learning Objectives: To learn about recent advances in electron beam therapy, including modulated electron beam therapy and dynamic electron arc therapy (DEAR). Put recent advances in the context of work that Dr. Ovadia pursued during his career in medical physics.

  6. WE-A-207-02: Electron Beam Therapy - Current Status and Future Directions

    International Nuclear Information System (INIS)

    Wu, Q.

    2015-01-01

    In memory of the significant contribution of Dr. Jacques Ovadia to electron beam techniques, this session will review recent, advanced techniques which are reinvigorating the science of electron beam radiation therapy. Recent research efforts in improving both the applicability and quality of the electron beam therapy will be discussed, including modulated electron beam radiotherapy (MERT) and dynamic electron arc radiotherapy (DEAR). Learning Objectives: To learn about recent advances in electron beam therapy, including modulated electron beam therapy and dynamic electron arc therapy (DEAR). Put recent advances in the context of work that Dr. Ovadia pursued during his career in medical physics

  7. Intraoperative radiotherapy of malignant pancreatic tumors - first results

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, S.; Glaser, K.; Url, M.; Frommhold, H.; Bodner, E.

    1987-02-01

    Thirteen patients suffering from adenocarcinomas of the pancreas were submitted to an intraoperative fast electron 'boost' therapy with or without percutaneous photon irradiation. A duodeno-cephalo-pancreatectomy with subsequent irradiation of the tumor bed could be performed in three patients. Ten patients were inoperable because of advanced tumors and formation of metastases. The average survival is 6.5 months, at present six patients are alive without major troubles. An analgetic effect was obtained in ten patients. The first results are encouraging with respect to local control, the little acute and chronic morbidity, and palliation achieved in advances stages.

  8. Intraoperative radiotherapy of malignant pancreatic tumors - first results

    International Nuclear Information System (INIS)

    Thurnher, S.; Glaser, K.; Url, M.; Frommhold, H.; Bodner, E.; Innsbruck Univ.

    1987-01-01

    Thirteen patients suffering from adenocarcinomas of the pancreas were submitted to an intraoperative fast electron 'boost' therapy with or without percutaneous photon irradiation. A duodeno-cephalo-pancreatectomy with subsequent irradiation of the tumor bed could be performed in three patients. Ten patients were inoperable because of advanced tumors and formation of metastases. The average survival is 6.5 months, at present six patients are alive without major troubles. An analgetic effect was obtained in ten patients. The first results are encouraging with respect to local control, the little acute and chronic morbidity, and palliation achieved in advances stages. (orig.) [de

  9. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

    International Nuclear Information System (INIS)

    Showalter, Shayna L.; Petroni, Gina; Trifiletti, Daniel M.; Libby, Bruce; Schroen, Anneke T.; Brenin, David R.; Dalal, Parchayi; Smolkin, Mark; Reardon, Kelli A.; Showalter, Timothy N.

    2016-01-01

    Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

  10. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Showalter, Shayna L., E-mail: snl2t@virginia.edu [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Petroni, Gina [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Trifiletti, Daniel M.; Libby, Bruce [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Schroen, Anneke T.; Brenin, David R. [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Dalal, Parchayi [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Smolkin, Mark [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Reardon, Kelli A.; Showalter, Timothy N. [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States)

    2016-09-01

    Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

  11. Dosimetric feasibility of using tungsten-based functional paper for flexible chest wall protectors in intraoperative electron radiotherapy for breast cancer

    Science.gov (United States)

    Kamomae, Takeshi; Monzen, Hajime; Kawamura, Mariko; Okudaira, Kuniyasu; Nakaya, Takayoshi; Mukoyama, Takashi; Miyake, Yoshikazu; Ishihara, Yoshitomo; Itoh, Yoshiyuki; Naganawa, Shinji

    2018-01-01

    Intraoperative electron radiotherapy (IOERT), which is an accelerated partial breast irradiation method, has been used for early-stage breast cancer treatment. In IOERT, a protective disk is inserted behind the target volume to minimize the dose received by normal tissues. However, to use such a disk, the surgical incision must be larger than the field size because the disk is manufactured from stiff and unyielding materials. In this study, the applicability of newly developed tungsten-based functional paper (TFP) was assessed as an alternative to the existing protective disk. The radiation-shielding performance of the TFP was verified through experimental measurements and Monte Carlo simulations. Percentage depth dose curves and lateral dose profiles with and without TFPs were measured and simulated on a dedicated IOERT accelerator. The number of piled-up TFPs was changed from 1 to 40. In the experimental measurements, the relative doses at the exit plane of the TFPs for 9 MeV were 42.7%, 9.2%, 0.2%, and 0.1% with 10, 20, 30, and 40 TFPs, respectively, whereas those for 12 MeV were 63.6%, 27.1%, 8.6%, and 0.2% with 10, 20, 30, and 40 TFPs, respectively. Slight dose enhancements caused by backscatter radiation from the TFPs were observed at the entrance plane of the TFPs at both beam energies. The results of the Monte Carlo simulation indicated the same tendency as the experimental measurements. Based on the experimental and simulated results, the radiation-shielding performances of 30 TFPs for 9 MeV and 40 TFPs for 12 MeV were confirmed to be acceptable and close to those of the existing protective disk. The findings of this study suggest the feasibility of using TFPs as flexible chest wall protectors in IOERT for breast cancer treatment.

  12. Dosimetric characteristics with spatial fractionation using electron grid therapy.

    Science.gov (United States)

    Meigooni, A S; Parker, S A; Zheng, J; Kalbaugh, K J; Regine, W F; Mohiuddin, M

    2002-01-01

    Recently, promising clinical results have been shown in the delivery of palliative treatments using megavoltage photon grid therapy. However, the use of megavoltage photon grid therapy is limited in the treatment of bulky superficial lesions where critical radiosensitive anatomical structures are present beyond tumor volumes. As a result, spatially fractionated electron grid therapy was investigated in this project. Dose distributions of 1.4-cm-thick cerrobend grid blocks were experimentally determined for electron beams ranging from 6 to 20 MeV. These blocks were designed and fabricated at out institution to fit into a 20 x 20-cm(2) electron cone of a commercially available linear accelerator. Beam profiles and percentage depth dose (PDD) curves were measured in Solid Water phantom material using radiographic film, LiF TLD, and ionometric techniques. Open-field PDD curves were compared with those of single holes grid with diameters of 1.5, 2.0, 2.5, 3.0, and 3.5 cm to find the optimum diameter. A 2.5-cm hole diameter was found to be the optimal size for all electron energies between 6 and 20 MeV. The results indicate peak-to-valley ratios decrease with depth and the largest ratio is found at Dmax. Also, the TLD measurements show that the dose under the blocked regions of the grid ranged from 9.7% to 39% of the dose beneath the grid holes, depending on the measurement location and beam energy.

  13. Intraoperative fluid therapy in neonates

    African Journals Online (AJOL)

    Differences from adults and children in physiology and anatomy of neonates inform our ... is based on energy expenditure indexed to bodyweight.2 Energy ... fragile and poorly keratinised.5 ... neonates means that very conservative fluid regimes in neonates ..... I make an estimation of insensible loss from the skin, viscera,.

  14. Energy and intensity modulated radiation therapy with electrons

    OpenAIRE

    Olofsson, Lennart

    2005-01-01

    In recent years intensity modulated radiation therapy with photons (xIMRT) has gained attention due to its ability to reduce the dose in the tissues close to the tumour volume. However, this technique also results in a large low dose volume. Electron IMRT (eIMRT) has the potential to reduce the integral dose to the patient due to the dose fall off in the electron depth dose curves. This dose fall off makes it possible to modulate the dose distribution in the direction of the beam by selecting...

  15. Skin protection by sucralfate cream during electron beam therapy

    International Nuclear Information System (INIS)

    Maiche, A.

    1994-01-01

    We performed a double-blind randomized study to compare the efficacy of sucralfate cream to a base cream in 50 breast cancer patients receiving postoperative electron beam therapy to their chest wall. The acute radiation reaction of the skin was statistically significantly prevented by the sucralfate cream. The recovery of the skin was also significantly faster in the sucralfate cream group. Side-effects due to the cream were rare. (orig./MG)

  16. Skin protection by sucralfate cream during electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Maiche, A. (Helsinki Univ. Central Hospital (Finland). Dept. of Radiotherapy and Oncology); Isokangas, O.P. (Helsinki Univ. Central Hospital (Finland). Dept. of Radiotherapy and Oncology); Groehn, P. (Deaconess Hospital, Helsinki (Finland))

    1994-01-01

    We performed a double-blind randomized study to compare the efficacy of sucralfate cream to a base cream in 50 breast cancer patients receiving postoperative electron beam therapy to their chest wall. The acute radiation reaction of the skin was statistically significantly prevented by the sucralfate cream. The recovery of the skin was also significantly faster in the sucralfate cream group. Side-effects due to the cream were rare. (orig./MG).

  17. WE-DE-BRA-10: Development of a Novel Scanning Beam Low-Energy Intraoperative Radiation Therapy (SBIORT) System for Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wears, B; Mohiuddin, I; Flynn, R; Waldron, T; Kim, Y; Allen, B; Xia, J [University of Iowa Hospitals and Clinics, Iowa City, IA (United States)

    2016-06-15

    Purpose: Developing a compact collimator system and validating a 3D surface imaging module for a scanning beam low-energy x-ray radiation therapy (SBIORT) system that enables delivery of non-uniform radiation dose to targets with irregular shapes intraoperatively. Methods: SBIORT consists of a low energy x-ray source, a custom compact collimator module, a robotic arm, and a 3D surface imaging module. The 3D surface imaging system (structure sensor) is utilized for treatment planning and motion monitoring of the surgical cavity. SBIORT can deliver non-uniform dose distributions by dynamically moving the x-ray source assembly along optimal paths with various collimator apertures. The compact collimator utilizes a dynamic shutter mechanism to form a variable square aperture. The accuracy and reproducibility of the collimator were evaluated using a high accuracy encoder and a high resolution camera platform. The dosimetrical characteristics of the collimator prototype were evaluated using EBT3 films with a Pantak Therapax unit. The accuracy and clinical feasibility of the 3D imaging system were evaluated using a phantom and a cadaver cavity. Results: The SBIORT collimator has a compact size: 66 mm diameter and 10 mm thickness with the maximum aperture of 20 mm. The mechanical experiment indicated the average accuracy of leaf position was 0.08 mm with a reproducibility of 0.25 mm at 95% confidence level. The dosimetry study indicated the collimator had a penumbra of 0.35 mm with a leaf transmission of 0.5%. 3D surface scans can be acquired in 5 seconds. The average difference between the acquired 3D surface and the ground truth is 1 mm with a standard deviation of 0.6 mm. Conclusion: This work demonstrates the feasibility of the compact collimator and 3D scanning system for the SBIORT. SBIORT is a way of delivering IORT with a compact system that requires minimum shielding of the procedure room. This research is supported by the University of Iowa Internal Funding

  18. High dose rate intraoperative radiation therapy (HDR-IORT) as part of the management strategy for locally advanced primary and recurrent rectal cancer

    International Nuclear Information System (INIS)

    Harrison, Louis B.; Minsky, Bruce D.; Enker, Warren E.; Mychalczak, Borys; Guillem, Jose; Paty, Philip B.; Anderson, Lowell; White, Carol; Cohen, Alfred M.

    1998-01-01

    Purpose: Primary unresectable and locally advanced recurrent rectal cancer presents a significant clinical challenge. Local failure rates are high in both situations. Under such circumstances, there is a significant need to safely deliver tumoricidal doses of radiation in an attempt to improve local control. For this reason, we have incorporated a new approach utilizing high dose rate intraoperative radiation therapy (HDR-IORT). Methods and Materials: Between 11/92-12/96, a total of 112 patients were explored, of which 68 patients were treated with HDR-IORT, and 66 are evaluable. The majority of the 44 patients were excluded for unresectable disease or for distant metastases which eluded preoperative imaging. There were 22 patients with primary unresectable disease, and 46 patients who presented with recurrent disease. The histology was adenocarcinoma in 64 patients, and squamous cell carcinoma in four patients. In general, the patients with primary unresectable disease received preoperative chemotherapy with 5-fluorouracil (5-FU) and leucovorin, and external beam irradiation to 4500-5040 cGy, followed by surgical resection and HDR-IORT (1000-2000 cGy). In general , the patients with recurrent disease were treated with surgical resection and HDR-IORT (1000-2000 cGy) alone. All surgical procedures were done in a dedicated operating room in the brachytherapy suite, so that HDR-IORT could be delivered using the Harrison-Anderson-Mick (HAM) applicator. The median follow-up is 17.5 months (1-48 mo). Results: In primary cases, the actuarial 2-year local control is 81%. For patients with negative margins, the local control was 92% vs. 38% for those with positive margins (p = 0.002). The 2-year actuarial disease-free survival was 69%; 77% for patients with negative margins vs. 38% for patients with positive margins (p = 0.03). For patients with recurrent disease, the 2-year actuarial local control rate was 63%. For patients with negative margins, it was 82%, while it was

  19. Phase II trial of combined surgical resection, high dose rate intraoperative radiation therapy, and external beam radiotherapy for malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Raben, A.; Rusch, V.; Mychalczak, B.; Ginsberg, R.; Burt, M.; Bains, M.; Francois, Damien; Harrison, L.B.

    1997-01-01

    Purpose: To determine the feasibility of combining extrapleural pneumonectomy (EPP) or pleurectomy / decortication (PD), high dose rate intraoperative radiation therapy (HDR-IORT) and postoperative external beam radiation hemithoracic radiation (EBHRT) to treat malignant pleural mesothelioma (MPM). Materials and Methods: From 3/94 through 9/94, 15 patients (pts) were enrolled on this trial. This included 3 females and 12 males with a median age of 59 (Range: 45-75). Eligibility criteria included biopsy proven MPM, no evidence of T4 or N3 disease by exam/CT/MRI, no evidence of metastatic disease, no previous treatment, and a Karnofsky performance status of ≥ 80%. Pts with pulmonary function tests permitting EPP, underwent EPP and HDR-IORT (N=7). The rest underwent PD/HDR-IORT (N=4). An intraoperative dose of 15 Gy was prescribed to a depth of 5 mm in tissue to the ipsilateral mediastinum, diaphragm, and chest wall. Postoperatively, 54 Gy of EBHRT was prescribed to the hemithorax, surgical scar and surgical drain site. The median surgical procedure time, median IORT time and median overall operating time was 554 minutes, 240 minutes, and 649 minutes respectively. The median dose of EBHRT was 50.4 Gy (Range 50-54 Gy). The median follow-up time is 8 months (Range: 3.5 to 28 months). Four of 15 pts had unresectable disease at the time of surgery and were taken off study. Results are presented in crude and actuarial analysis. Results: A complete resection of all visible gross disease was accomplished in 10 pts. One pt had a single focus of gross residual disease (less than 5 mm in size) left behind in the chest wall. The overall complication rate was 54%. Treatment related mortality occurred in 2 pts (18%) at 1 and 7 months respectively. This was attributed to ARDS in 1 pt (EPP/HDR-IORT) and radiation pneumonitis combined with a tracheoesophageal fistula in 1 pt (PD/HDR-IORT). Of the 6 remaining pts undergoing EPP/HDR-IORT, 2 pts developed a postoperative empyema with

  20. Electronic cigarettes: health impact, nicotine replacement therapy, regulations

    Directory of Open Access Journals (Sweden)

    Zygmunt Zdrojewicz

    2017-03-01

    Full Text Available While the adverse effects of conventional cigarettes on human health have been thoroughly examined, in the last 15 years we have witnessed the birth of electronic cigarettes. There are many types of these devices available on the market. Studies are still underway to determine their negative impact on the human body. Electronic cigarettes comprise of power supply and a vaporising system. The user inhales the aerosol produced by heating up the liquid containing nicotine. In contrast with conventional cigarettes, the tobacco is not combusted, thus the compositions of the aerosol and cigarette smoke are considerably different. Out of 93 chemical substances present in the e-cigarette smoke, the aerosol contains only acetaldehyde, acetone, acrolein, formaldehyde and nicotine. More toxic substances, such as polycyclic aromatic hydrocarbons and heavy metals, are not present. The amount of evidence suggesting electronic cigarettes’ harmful effects on the human body is constantly increasing. Some reports imply that the electronic cigarettes negatively influence pregnancy, human psyche, respiratory and cardiovascular systems. They might also be involved in oncogenesis. With electronic cigarettes constantly gaining popularity, the question about the adverse effects of passive smoking becomes increasingly more relevant. Although various methods of helping people cease smoking or delivering nicotine to their bodies without burning toxic substances are being explored, electronic cigarettes are not recommended in nicotine substitution therapy. Legal regulations regarding electronic cigarettes are still being worked on. The purpose of this paper is to evaluate the effects electronic cigarettes have on the human’s health.

  1. Dosimetric intercomparison between protons and electrons therapies applied to retinoblastoma

    International Nuclear Information System (INIS)

    Braga, Flavia Vieira

    2008-01-01

    In this work we propose a construction of a simple human eye model in order to simulate the dosimetric response for a treatment with protons and electrons in a retinoblastoma cancer. The computational tool used in this simulation was the Geant4 code, in the version 4.9.1, all these package are free and permit simulate the interaction of radiation with matter. In our simulation we use a box with 4 cm side, with water, for represent the human eye. The simulation was performed considering mono energetics beams of protons and electrons with energy range between 50 and 70 MeV for protons and 2 and 10 MeV for electrons. The simulation was based on the advanced hadron therapy example of the Geant 4 code. In these example the phantom is divided in voxels with 0.2 mm side and it is generated the energy deposited in each voxel. The simulation results show the energy deliver in each voxel, with these energie we can calculate the dose deposited in that region. We can see the dose profile of, proton and electron, and we can see in both cases that for protons the position of delivered dose is well know, that happen in the position where the proton stop, for electrons the energies is delivered along the way and pass the desired position for high dose deposition. (author)

  2. Cutaneous complication after electron beam therapy in breast cancer

    Directory of Open Access Journals (Sweden)

    M Jalilian

    2005-11-01

    Full Text Available Background: Breast cancer is the most common cancer in women and the second cause of death among them. There are several treatment methods for breast cancer, one of which is radiation therapy. There are two important methods of radiation therapy: tangential field and single oppositional field. Main goal of this study is evaluation of factors that have a role in producing acute side effects such as skin burning in breast cancer patients treated by electron beam,in order to decrease these side effects. Methods: From 1/2003 through 7/2004, 200 consecutive patients were evaluated during 18 months in seid-al-shohad hospital, whose mean age was 49 years old. In this study a questionnaire was used including some questions about personal profile such as patient's name, address, registration number, age and some other factors. All patients who were candidated to enter in this investigation filled out the questionnaire at the end of radiation therapy. The patients were examined and their skin burning grades were evaluated by RTOG scale. Data were analyzed by chi-square test using SPSS 11 software. Results: None of patients showed grades O or 4 of burning. 31.5 % of Patients showed grade 1, 64.5 % showed grade 2, 4 % showed grade 3 of burning. There was statistically significant correlation between posterior axillary field and skin burning and there wasnot any meaning between the other factors. Conclusion: It is necessary to pay more attention to posterior axillary field planning including field size, location, photon energy, depth and dose of treatment. Keywords: breast cancer, electron beam radiation therapy, skin burning

  3. [Intraoperative multidimensional visualization].

    Science.gov (United States)

    Sperling, J; Kauffels, A; Grade, M; Alves, F; Kühn, P; Ghadimi, B M

    2016-12-01

    Modern intraoperative techniques of visualization are increasingly being applied in general and visceral surgery. The combination of diverse techniques provides the possibility of multidimensional intraoperative visualization of specific anatomical structures. Thus, it is possible to differentiate between normal tissue and tumor tissue and therefore exactly define tumor margins. The aim of intraoperative visualization of tissue that is to be resected and tissue that should be spared is to lead to a rational balance between oncological and functional results. Moreover, these techniques help to analyze the physiology and integrity of tissues. Using these methods surgeons are able to analyze tissue perfusion and oxygenation. However, to date it is not clear to what extent these imaging techniques are relevant in the clinical routine. The present manuscript reviews the relevant modern visualization techniques focusing on intraoperative computed tomography and magnetic resonance imaging as well as augmented reality, fluorescence imaging and optoacoustic imaging.

  4. Electron string ion sources for carbon ion cancer therapy accelerators

    Science.gov (United States)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Katagiri, K.; Noda, K.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B.

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C4+ and C6+ ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 1010 C4+ ions per pulse and about 5 × 109 C6+ ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 1011 C6+ ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the 11C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C4+ ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of 11C, transporting to the tumor with the primary accelerated 11C4+ beam, this efficiency is preliminarily considered to be large enough to produce the 11C4+ beam from radioactive methane and to inject this beam into synchrotrons.

  5. Intra-operative radiotherapy in oncology

    International Nuclear Information System (INIS)

    Gerard, J.P.; Braillon, G.; Sentenac, I.; Calvo, F.; Dubois, J.B.; Saint-Aubert, B.; Guillemin, C.; Roussel, A.

    1991-01-01

    This article is about a treatment used more and more frequently in the world, for some neoplasms: Intra-operative radiotherapy under electron beams. The main neoplasms concerned by this treatment are the stomach, pancreas, rectum, bladder, uterus cervix neoplasms and peritoneal sarcoma [fr

  6. Electron arc therapy: chest wall irradiation of breast cancer patients

    International Nuclear Information System (INIS)

    McNeely, L.K.; Jacobson, G.M.; Leavitt, D.D.; Stewart, J.R.

    1988-01-01

    From 1980 to October 1985 we treated 45 breast cancer patients with electron arc therapy. This technique was used in situations where optimal treatment with fixed photon or electron beams was technically difficult: long scars, recurrent tumor extending across midline or to the posterior thorax, or marked variation in depth of target tissue. Forty-four patients were treated following mastectomy: 35 electively because of high risk of local failure, and 9 following local recurrence. One patient with advanced local regional disease was treated primarily. The target volume boundaries on the chest wall were defined by a foam lined cerrobend cast which rested on the patient during treatment, functioning as a tertiary collimator. A variable width secondary collimator was used to account for changes in the radius of the thorax from superior to inferior border. All patients had computerized tomography performed to determine Internal Mammary Chain depth and chest wall thickness. Electron energies were selected based on these thicknesses and often variable energies over different segments of the arc were used. The chest wall and regional node areas were irradiated to 45 Gy-50 Gy in 5-6 weeks by this technique. The supraclavicular and upper axillary nodes were treated by a direct anterior photon field abutted to the superior edge of the electron arc field. Follow-up is from 10-73 months with a median of 50 months. No major complications were observed. Acute and late effects and local control are comparable to standard chest wall irradiation. The disadvantages of this technique are that the preparation of the tertiary field defining cast and CT treatment planning are labor intensive and expensive. The advantage is that for specific clinical situations large areas of chest wall with marked topographical variation can be optimally, homogeneously irradiated while sparing normal uninvolved tissues

  7. Electron string ion sources for carbon ion cancer therapy accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B. [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Katagiri, K.; Noda, K. [National Institute of Radiological Science, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2015-08-15

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C{sup 4+} and C{sup 6+} ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 10{sup 10} C{sup 4+} ions per pulse and about 5 × 10{sup 9} C{sup 6+} ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 10{sup 11} C{sup 6+} ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the {sup 11}C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C{sup 4+} ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of {sup 11}C, transporting to the tumor with the primary accelerated {sup 11}C{sup 4+} beam, this efficiency is preliminarily considered to be large enough to produce the {sup 11}C{sup 4+} beam from radioactive methane and to inject this beam into synchrotrons.

  8. Intraoperative cranial nerve monitoring.

    Science.gov (United States)

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  9. On bolus for megavoltage photon and electron radiation therapy

    International Nuclear Information System (INIS)

    Vyas, Vedang; Palmer, Lisa; Mudge, Ray; Jiang, Runqing; Fleck, Andre; Schaly, Bryan; Osei, Ernest; Charland, Paule

    2013-01-01

    Frequently, in radiation therapy one must treat superficial lesions on cancer patients; these are at or adjacent to the skin. Megavoltage photon radiotherapy penetrates through the skin to irradiate deep-seated tumors, with skin-sparing property. Hence, to treat superficial lesions, one must use a layer of scattering material to feign as the skin surface. Although megavoltage electron beams are used for superficial treatments, one occasionally needs to enhance the dose near the surface. Such is the function of a “bolus,” a natural or synthetically developed material that acts as a layer of tissue to provide a more effective treatment to the superficial lesions. Other uses of boluses are to correct for varying surface contours and to add scattering material around the patient's surface. Materials used as bolus vary from simple water to metal and include various mixtures and compounds. Even with the modernization of the technology for external-beam therapy and the emergence of various commercial boluses, the preparation and utilization of a bolus in clinical radiotherapy remains an art. Considering the varying experiences and practices, this paper briefly summarizes available boluses that have been proposed and are employed in clinical radiotherapy. Although this review is not exhaustive, it provides some initial guidance and answers questions that may arise in clinical practice

  10. Multimodal treatment utilizing intraoperative radiotherapy for advanced cancer of the pancreas

    International Nuclear Information System (INIS)

    Onodera, Tokio

    1982-01-01

    A multimodal treatment was consisted of intraoperative radiation, external radiation, by-pass operation, chemotherapy and total parenteral nutrition if necessary to cover decreased oral-intake. Thirty-three cases were subjected to this therapy for 6 years. The stage of the tumors varied from a localized tumor in the pancreas to a huge tumor with multiple metastases, though the latter abandoned recently to be contraindication to this therapy. At laparotomy, a high energy electron beam was irradiated to the tumor with a dosage of 3,000 rad using a 20 MeV Betatron. The tumor was carefully prepared in order to avoid irradiating the duodenum and stomach. Choledochojejunostomy and gastrojejunostomy were performed in almost all of patients with cancer of head of pancreas. In some patients, external radiation was added with a dosage of 3,000 rad by linear X-ray. After radiotherapy, chemotherapy employing 5-FU or FT-207 was continued including. The survival time after this therapy was varied mainly according to the stages of the tumor. In patients with multiple metastasis to the liver or peritoneal dissemination, no remarkable effects were obtained by this therapy. On the otherhand, among 14 patients with localized tumor in the pancreas, 7 survived more than one year and the mean survival time of treated patients was nevershorter than that of patients who received resection of the tumor. Most of the treated patients could spend at home until their condition became critical, because by-pass operation could overcome jaundice or the duodenal stenosis and intraoperative radiation could palliate the pain of cancer of pancreas. Tumor effect of intraoperative radiation was confirmed by both of the second laporatomy for twice intraoperative radiation and laparatomy. (author)

  11. Intraoperative ultrasound in neurosurgery

    International Nuclear Information System (INIS)

    Velasco, J.; Manzanares, R.; Fernandez, L.; Hernando, A.; Ramos, M. del Mar; Garcia, R.

    1996-01-01

    The present work is a review of the major indications for intraoperative ultrasound in the field of neurosurgery, stressing the exploratory method and describing what we consider to be the most illustrative cases. We attempt to provide a thorough view of this constantly developing technique which, despite its great practical usefulness, may be being underemployed. (Author) 47 refs

  12. Intraoperative radiotherapy for pancreatic carcinoma

    International Nuclear Information System (INIS)

    Nishimura, Akira; Iida, Koyo; Sato, Shigehiro; Sakata, Suo

    1986-01-01

    Twenty-eight patients with pancreatic carcinoma, 23 (82 %) of whom had Stage III or IV, received intraoperative radiotherapy (IOR) with curative or non-curative surgery. Electron beams (10 to 18 MeV) with doses of 20 to 40 Gy were delivered to the tumor. Eight of 26 patients with unresectable tumor had postoperative external irradiation of 10.5 to 50 Gy. Abdominal and back pain relief was achieved after IOR in 12 (71 %) and in 6 (60 %) of the 26 patients, respectively. Appetite was promoted in 11 patients. In the case of unresectable carcinoma, survival time tended to prolong in the 8 patients receiving both IOR and postoperative external irradiation. One patient developed perforation of the colon probably caused by IOR. (Namekawa, K.)

  13. Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy

    International Nuclear Information System (INIS)

    Al-Yahya, Khalid; Verhaegen, Frank; Seuntjens, Jan

    2007-01-01

    Despite the capability of energy modulated electron therapy (EMET) to achieve highly conformal dose distributions in superficial targets it has not been widely implemented due to problems inherent in electron beam radiotherapy such as planning dosimetry accuracy, and verification as well as a lack of systems for automated delivery. In previous work we proposed a novel technique to deliver EMET using an automated 'few leaf electron collimator' (FLEC) that consists of four motor-driven leaves fit in a standard clinical electron beam applicator. Integrated with a Monte Carlo based optimization algorithm that utilizes patient-specific dose kernels, a treatment delivery was incorporated within the linear accelerator operation. The FLEC was envisioned to work as an accessory tool added to the clinical accelerator. In this article the design and construction of the FLEC prototype that match our compact design goals are presented. It is controlled using an in-house developed EMET controller. The structure of the software and the hardware characteristics of the EMET controller are demonstrated. Using a parallel plate ionization chamber, output measurements were obtained to validate the Monte Carlo calculations for a range of fields with different energies and sizes. Further verifications were also performed for comparing 1-D and 2-D dose distributions using energy independent radiochromic films. Comparisons between Monte Carlo calculations and measurements of complex intensity map deliveries show an overall agreement to within ±3%. This work confirms our design objectives of the FLEC that allow for automated delivery of EMET. Furthermore, the Monte Carlo dose calculation engine required for EMET planning was validated. The result supports the potential of the prototype FLEC for the planning and delivery of EMET

  14. Intraoperative radiotherapy - Current status

    International Nuclear Information System (INIS)

    Gunderson, Leonard L.; Willett, Christopher G.; Harrison, Louis B.

    1997-01-01

    Purpose/Objective: Intraoperative irradiation (IORT) in its broadest sense refers to the delivery of irradiation at the time of an operation. This refresher course will discuss the use of both electrons (IOERT) and high dose rate brachytherapy (IOHDR) in conjunction with surgical exploration and resection ± external irradiation/chemotherapy. Both IORT methods have evolved with similar philosophies as an attempt to achieve higher effective doses of irradiation while dose limiting structures are surgically displaced. The rationale for each is supported by excellent local control ± survival results achieved with brachytherapy alone or as a boost to external irradiation in organ preservation efforts in traditional sites (head and neck, breast, gynecologic) wherein a boost dose could be delivered to smaller volumes than could usually be accomplished with external irradiation alone. IOERT has been a tool in modern radiotherapy in Japan since the 1960's and in the U.S. since the mid 1970's. Results from randomized and nonrandomized trials will be presented in the refresher course with major emphasis on GI sites (gastric, pancreas, colorectal) since the data is more mature. While the largest clinical experience with IOERT (± external irradiation/chemotherapy, maximal resection) has been with gastrointestinal cancers in adults, moderate experience has also been obtained with locally advanced retroperitoneal sarcomas and recurrent genitourinary and gynecologic cancers. With primary colorectal cancers that are unresectable for cure or for locally recurrent colorectal cancers, both local control and long-term survival appear to be improved with the aggressive combinations including IOERT when compared to results achieved with conventional treatment. When residual disease exists after resection of gastric cancers, IOERT ± external radiation has achieved optimistic survival results in trials in Japan, the U.S., Spain and China. With locally unresectable pancreatic cancer, an

  15. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    International Nuclear Information System (INIS)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.; Henkelmann, Gregory; Chu, Connel; Carver, Robert A.

    2013-01-01

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94

  16. Application of the electron pencil beam redefinition algorithm to electron arc therapy

    International Nuclear Information System (INIS)

    Chi, P.-C.M.; Hogstrom, Kenneth R.; Starkschall, George; Boyd, Robert A.; Tucker, Susan L.; Antolak, John A.

    2006-01-01

    This project investigated the potential of summing fixed-beam dose distributions calculated using the pencil-beam redefinition algorithm (PBRA) at small angular steps (1 deg.) to model an electron arc therapy beam. The PRBA, previously modified to model skin collimation, was modified further by incorporating two correction factors. One correction factor that is energy, SSD (source-to-surface distance), and field-width dependent constrained the calculated dose output to be the same as the measured dose output for fixed-beam geometries within the range of field widths and SSDs encountered in arc therapy. Another correction factor (single field-width correction factor for each energy) compensated for large-angle scattering not being modeled, allowing a more accurate calculation of dose output at mid arc. The PBRA was commissioned to accurately calculate dose in a water phantom for fixed-beam geometries typical of electron arc therapy. Calculated central-axis depth doses agreed with measured doses to within 2% in the low-dose gradient regions and within 1-mm in the high-dose gradient regions. Off-axis doses agreed to within 2 mm in the high-dose gradient regions and within 3% in the low-dose gradient regions. Arced-beam calculations of dose output and depth dose at mid arc were evaluated by comparing to data measured using two cylindrical water phantoms with radii of 12 and 15 cm at 10 and 15 MeV. Dose output was measured for all combinations of phantom radii of curvature, collimator widths (4, 5, and 6 cm), and arc angles (0 deg., 20 deg., 40 deg., 60 deg., 80 deg., and 90 deg.) for both beam energies. Results showed the calculated mid-arc dose output to agree within 2% of measurement for all combinations. For a 90 deg.arc angle and 5x20 cm 2 field size, the calculated mid-arc depth dose in the low-dose gradient region agreed to within 2% of measurement for all depths at 10 MeV and for depths greater than depth of dose maximum R 100 at 15 MeV. For depths in the

  17. The Art of Intraoperative Glioma Identification

    Directory of Open Access Journals (Sweden)

    Zoe Z Zhang

    2015-07-01

    Full Text Available A major dilemma in brain tumor surgery is the identification of tumor boundaries to maximize tumor excision and minimize postoperative neurological damage. Gliomas, especially low-grade tumors, and normal brain have a similar color and texture which poses a challenge to the neurosurgeon. Advances in glioma resection techniques combine the experience of the neurosurgeon and various advanced technologies. Intraoperative methods to delineate gliomas from normal tissue consist of 1 image-based navigation, 2 intraoperative sampling, 3 electrophysiological monitoring, and 4 enhanced visual tumor demarcation. The advantages and disadvantages of each technique are discussed. A combination of these methods is becoming widely accepted in routine glioma surgery. Gross total resection in conjunction with radiation, chemotherapy, or immune/gene therapy may increase the rates of cure in this devastating disease.

  18. [Intraoperative floppy iris syndrome].

    Science.gov (United States)

    Mazal, Z

    2007-04-01

    In the year 2005, Chang and Cambell described unusual reaction of the iris during the cataract surgery in patients treated with tamsulosine. This was named as IFIS, an acronym for the Intraoperative Floppy Iris Syndrome. In its advanced stage, the syndrome is characterized by insufficient mydfiasis before the surgery, narrowing of the pupil during the surgery, its impossible dilatation during the surgery by means of stretching, unusual elasticity of the pupilar margin, surging and fluttering iris with tendency to prolapse. The same manifestations we observed in our patients and we confirm the direct connection with tamsulosine hydrochloride treatment. Tamsulosine is the antagonist of alpha 1A adrenergic receptors whose are present, except in the smooth musculature of the prostate gland and the urinary bladder, in the iris dilator as well. At the same time we observed this syndrome rarely in some patients not using tamsulosine. In most cases, these patients were treated with antipsychotic drugs.

  19. Awareness and Use of Electronic Health Records in Entry-Level Occupational Therapy and Occupational Therapy Assistant Curricula

    Directory of Open Access Journals (Sweden)

    Louis F. Dmytryk

    2017-03-01

    Full Text Available The Accreditation Council for Occupational Therapy Education (ACOTE requires programs to instruct entrylevel occupational therapy (OT and occupational therapy assistant (OTA students in technology that may include electronic documentation systems, distance communication, virtual environments, and telehealth (standard B1.8. At this time, there are no publications describing if and how electronic health record (EHR instruction is implemented in entry-level OT and OTA programs. The purpose of this study is to investigate awareness and use of EHRs in entry-level OT and OTA curricula. Respondents from 76 nationally accredited entry-level programs (two OT doctoral, 24 OT masters, two OT combined bachelors/masters, and 48 OTA completed a survey. The findings showed inconsistent and incomplete EHR instruction in entry-level OT and OTA education. This study provides a baseline for investigating best practices in EHR education for entrylevel OT and OTA students

  20. Effects of intraoperative irradiation and intraoperative hyperthermia on canine sciatic nerve: neurologic and electrophysiologic study

    International Nuclear Information System (INIS)

    Vujaskovic, Zeljko; Gillette, Sharon M.; Powers, Barbara E.; Stukel, Therese A.; LaRue, Susan M.; Gillette, Edward L.; Borak, Thomas B.; Scott, Robert J.; Weiss, Julia; Colacchio, Thomas A.

    1996-01-01

    Purpose: Late radiation injury to peripheral nerve may be the limiting factor in the clinical application of intraoperative radiation therapy (IORT). The combination of IORT with intraoperative hyperthermia (IOHT) raises specific concerns regarding the effects on certain normal tissues such as peripheral nerve, which might be included in the treatment field. The objective of this study was to compare the effect of IORT alone to the effect of IORT combined with IOHT on peripheral nerve in normal beagle dogs. Methods and Materials: Young adult beagle dogs were randomized into five groups of three to five dogs each to receive IORT doses of 16, 20, 24, 28, or 32 Gy to 5 cm of surgically exposed right sciatic nerve using 6 MeV electrons and six groups of four to five dogs each received IORT doses of 0, 12, 16, 20, 24, or 28 Gy simultaneously with 44 deg. C of IOHT for 60 min. IOHT was performed using a water circulating hyperthermia device with a multichannel thermometry system on the surgically exposed sciatic nerve. Neurologic and electrophysiologic examinations were done before and monthly after treatment for 24 months. Electrophysiologic studies included electromyographic (EMG) examinations of motor function, as well as motor nerve conduction velocities studies. Results: Two years after treatment, the effective dose for 50% complication (ED 50 ) for limb paresis in dogs exposed to IORT only was 22 Gy. The ED 50 for paresis in dogs exposed to IORT combined with IOHT was 15 Gy. The thermal enhancement ratio (TER) was 1.5. Electrophysiologic studies showed more prominent changes such as EMG abnormalities, decrease in conduction velocity and amplitude of the action potential, and complete conduction block in dogs that received the combination of IORT and IOHT. The latency to development of peripheral neuropathies was shorter for dogs exposed to the combined treatment. Conclusion: The probability of developing peripheral neuropathies in a large animal model was higher

  1. MO-A-BRB-03: Integration Issues in Electronic Charting for External Beam Therapy

    International Nuclear Information System (INIS)

    Sutlief, S.

    2015-01-01

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy

  2. Overview of intraoperative MRI in neurosurgery

    International Nuclear Information System (INIS)

    Shiino, Akihiko; Matsuda, Masayuki

    2002-01-01

    This review describes usefulness, prospect and present problems of intraoperative MRI in neurosurgery. MRI equipments for the surgery have to have a wide, open space and have those magnets of short cylindrical, biplanar (clam shell), dual air core superconducting solenoidal (double doughnut) and targeted FOV (field of view) type. Devices required for the surgery are specific and in author's facility, they are classified into 4 zones depending on the region of their use. Application of the surgery involves biopsy, drainage of cyst and abscess, hematoma evacuation, nerve block, thermotherapy (interstitial laser, RF ablation, focused untrasonic and cryosurgery), local drug therapy, chemoablation, vascular intervention and tumor extraction, of which actual procedures and pictures are presented together with, in particular, MR-guided thermotherapy, ablation therapy of brain tumors, endoscopic surgery and minimally invasive therapy of the spine. A navigation software, 3D SlicerTM system, is introduced for interventional imaging. Safety measures are emphasized for the operation. (K.H.)

  3. Overview of intraoperative MRI in neurosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Shiino, Akihiko; Matsuda, Masayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    2002-01-01

    This review describes usefulness, prospect and present problems of intraoperative MRI in neurosurgery. MRI equipments for the surgery have to have a wide, open space and have those magnets of short cylindrical, biplanar (clam shell), dual air core superconducting solenoidal (double doughnut) and targeted FOV (field of view) type. Devices required for the surgery are specific and in author's facility, they are classified into 4 zones depending on the region of their use. Application of the surgery involves biopsy, drainage of cyst and abscess, hematoma evacuation, nerve block, thermotherapy (interstitial laser, RF ablation, focused untrasonic and cryosurgery), local drug therapy, chemoablation, vascular intervention and tumor extraction, of which actual procedures and pictures are presented together with, in particular, MR-guided thermotherapy, ablation therapy of brain tumors, endoscopic surgery and minimally invasive therapy of the spine. A navigation software, 3D SlicerTM system, is introduced for interventional imaging. Safety measures are emphasized for the operation. (K.H.)

  4. Protocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness

    Directory of Open Access Journals (Sweden)

    Avidan Michael S

    2009-11-01

    Full Text Available Abstract Background The incidence of intraoperative awareness with explicit recall is 1-2/1000 cases in the United States. The Bispectral Index monitor is an electroencephalographic method of assessing anesthetic depth that has been shown in one prospective study to reduce the incidence of awareness in the high-risk population. In the B-Aware trial, the number needed to treat in order to prevent one case of awareness in the high-risk population was 138. Since the number needed to treat and the associated cost of treatment would be much higher in the general population, the efficacy of the Bispectral Index monitor in preventing awareness in all anesthetized patients needs to be clearly established. This is especially true given the findings of the B-Unaware trial, which demonstrated no significant difference between protocols based on the Bispectral Index monitor or minimum alveolar concentration for the reduction of awareness in high risk patients. Methods/Design To evaluate efficacy in the general population, we are conducting a prospective, randomized, controlled trial comparing the Bispectral Index monitor to a non-electroencephalographic gauge of anesthetic depth. The total recruitment for the study is targeted for 30,000 patients at both low and high risk for awareness. We have developed a novel algorithm that is capable of real-time analysis of our electronic perioperative information system. In one arm of the study, anesthesia providers will receive an electronic page if the Bispectral Index value is >60. In the other arm of the study, anesthesia providers will receive a page if the age-adjusted minimum alveolar concentration is Discussion Awareness during general anesthesia is a persistent problem and the role of the Bispectral Index monitor in its prevention is still unclear. The Michigan Awareness Control Study is the largest prospective trial of awareness prevention ever conducted. Trial Registration Clinical Trial NCT00689091

  5. IORT with electrons as boost strategy during breast conserving therapy in limited stage breast cancer: results of an ISIORT pooled analysis

    International Nuclear Information System (INIS)

    Sedlmayer, F.; Fastner, G.; Merz, F.; Deutschmann, H.; Reitsamer, R.; Menzel, C.; Ciabattoni, A.; Petrucci, A.; Hager, E.; Willich, N.; Orecchia, R.; Valentini, V.

    2007-01-01

    There is common consensus that postoperative whole-breast irradiation with doses around 50 Gy remains the gold standard for local treatment after breast conserving surgery (BCS). A substantial benefit of an additional boost with 16 Gy to the tumor bed was recently confirmed by a re-analysis of the EORTC trial data: local recurrence rates were reduced by 50% in all age groups. The idea of a Linac-based IORT with electrons (IOERT) during breast conserving surgery is the delivery of a single boost dose to the tumor bed with utmost precision, due to direct visualization. However, the published data about boost-IOERT for breast cancer are scarce and rarely updated with only few centers participating. Therefore, we initiated a collaborative analysis within the European Group of the International Society of Intraoperative Radiotherapy (ISIORT). A pooled analysis has been performed by 6 institutions of the ISIORT-Europe using comparable methods, sequencing and dosage in intra- and postoperative radiotherapy during BCT. Between 10/98 and 05/05, 1131 patients were treated. Patients' characteristics, histologic workup and tumor staging are summarized in Table 1. Sixty percent of all patients (671 pat.) presented with at least one risk factor for local recurrence in terms of tumor size > 2 cm, high grading, young age < 45 years and/or positive axillary nodes. Breast tumor resection was primarily performed by circular incision. Surgical margins were assessed by frozen section after tumorectomy. Prior to IOERT, the tissue surrounding the excision cavity was temporarily approximated by sutures to bring it in reach of the electron beam. In most cases, intraoperative sonography was performed for depth measurement allowing dose prescription, alternatively mobile CT or direct ruler measurement was used. During IOERT, median single fractional doses of 9,7 Gy (range 5-17) were applied to the 90% reference isodose, using round perspex tubes with 5-8 cm diameter and electron energies of

  6. Kyphoplasty combined with intraoperative radiotherapy (Kypho-IORT). Alternative therapy for patients with oligometastatic spinal metastases; Kyphoplastie kombiniert mit intraoperativer Radiotherapie (Kypho-IORT). Therapiealternative fuer den oligometastasierten Patienten mit Wirbelsaeulenmetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Bludau, F.; Obertacke, U. [Universitaetsklinikum Mannheim, Med. Fakultaet Mannheim der Universitaet Heidelberg, Orthopaedisch-Unfallchirurgisches Zentrum, Mannheim (Germany); Reis, T.; Schneider, F.; Clausen, S.; Wenz, F. [Universitaetsklinikum Mannheim, Med. Fakultaet Mannheim der Universitaet Heidelberg, Klinik fuer Strahlentherapie und Radioonkologie, Mannheim (Germany)

    2015-10-15

    Due to a more effective systemic therapy the survival of patients suffering from malignant tumors has been significantly improved but a longer life span is often associated with a higher incidence of osseous metastases. The majority of these metastases are localized in the spine causing pain, instability and neurological impairments. The interdisciplinary management of spinal metastases previously consisted of stabilization followed by fractionated external body radiation therapy. A reduction in procedural severity and morbidity as well as consideration of self-sufficiency and hospitalization time are important target parameters for these palliative patients. Kyphoplasty combined with intraoperative radiotherapy (Kypho-IORT) is one of several modern treatment options, which involves a minimally invasive procedure with local high-dose transpedicular irradiation of the spine with low-energy (50 kV) X-rays. Immediately following irradiation, stabilization of the spine is carried out using kyphoplasty via the same access route so that a single stage procedure with excellent pain reduction and good local tumor control can be achieved. This article presents clinical data for this procedure and the different fields of indications are critically reviewed and compared to other therapy options. Methodological improvements and options for further individualization of therapy are demonstrated. The Kypho-IORT procedure is a safe, feasible and beneficial modern treatment option for instant stabilization and local tumor control in patients with spinal metastases. More than 100 operations have been successfully performed so that the method can be deemed suitable for inclusion in the clinical routine. A phase II dose escalation study has now been completed and submitted for publication and a 2-arm non-inferiority trial (phase III study) for comparison with conventional irradiation is in progress. (orig.) [German] Durch verbesserte onkologische Therapie kommt es nicht nur zu einer

  7. Intraoperative radiotherapy in primary rectal cancer; Intraoperative Radiotherapie des primaeren Rektumkarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Mund, Christian

    2013-06-17

    According to the results of several studies intraoperative radiotherapy seems to influence local control for primary rectal cancer in UICC-Stage II / III positively, though recommendations in therapy cannot be given as studies of high evidence level do not exist. As IORT is rarely available and makes patient recruitment difficult, prospective randomised trials have not been carried out yet. This emphasizes the importance of non-randomised trials for an evaluation of IORT. A comparison of 21 patients with locally advanced rectal cancer who had been treated with intraoperative radiation therapy and 21 similar cases without an application of IORT could not show any significant improvements in prognosis (recurrences, metastases and disease-specific survival). Nevertheless the employment of intraoperative radiation showed a trend in improvement of local control. This hast been shown by several other studies before. Thus the application of IORT in patients with locally advanced rectal cancer is considered a useful part in multimodal treatment and should further be evaluated in specialized centres. In case-control studies 1:1-matching leads to a good comparability of groups and renders conclusions of high internal validity possible. To gain a sufficient power, this type of trials should however primarily be carried out by centres with a high number of cases.

  8. Pre- and intraoperative volume determination of craniopharyngioma cysts

    Energy Technology Data Exchange (ETDEWEB)

    Georgi, P.; Strauss, L.; Sturm, V.; Ostertag, H.; Sinn, H.; Rommel, T.

    1980-08-01

    Exact cystic volume measurement is a prerequisite to proper /sup 90/Y dosage in the therapy of intracavitary monocystic craniopharyngiomas. The method of intraoperative volume measurement by a radionuclide dilution technique is compared to results abtained by preoperative using computer tomography. Both methods gave congruous results. It is pointed out that gamma camera scintigrams are essential for the early detection of complications.

  9. Targeted intraoperative radiotherapy in oncology

    CERN Document Server

    Keshtgar, Mohammed; Wenz, Frederik

    2014-01-01

    Targeted intraoperative radiotherapy is a major advance in the management of cancer patients. With an emphasis on practical aspects, this book offers an ideal introduction to this innovative  technology for clinicians.

  10. Phase II trial of combined surgical resection, intraoperative high dose rate brachytherapy (IORT), and external beam radiation therapy (EBRT) for malignant pleural mesothelioma (MPM)

    International Nuclear Information System (INIS)

    Raben, A.; Rusch, V.; Mychalczak, B.; Schupak, K.; Ginsburg, R.; Burt, M.; Bains, M.; Harrison, L.B.

    1996-01-01

    respiratory distress and expired. Two pts developed a postoperative empyema with bronchial stump leak; with 1 pt developing bleeding from mediastinal vessels at 7 months. This was felt to be related to late radiation toxicity. Wound dehiscence of the thoracotomy incision occurred in 1 pt. Of the 4 pts undergoing PD, 1 pt developed a tracheoesophageal fistula, and 1 developed a postoperative chest tube leak. IORT in conjunction with EPP led to prohibitive local complications and has been discontinued. Although follow-up is short, IORT with PD shows no improvement in local control compared to our historical experience. Local control with EPP/EBRT has thus far been excellent with most patients relapsing outside of the EBRT field, in distinct contrast to the reported pattern of disease progression in MPM, emphasizing the need for improved systemic therapy

  11. Use of an electron reflector to improve dose uniformity at the vertex during total skin electron therapy

    International Nuclear Information System (INIS)

    Peters, V.G.

    2000-01-01

    Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation

  12. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve : Histopathological and morphometric studies

    NARCIS (Netherlands)

    Vujaskovic, Z; Powers, BE; Paardekoper, G; Gillette, SM; Gillette, EL; Colacchio, TA

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate

  13. Secondary-electron-bremsstrahlung imaging for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Mitsutaka; Nagao, Yuto [Takasaki Advanced Radiation Research Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, 1233 Watanuki-Machi, Takasaki, Gunma (Japan); Ando, Koki; Yamamoto, Seiichi [Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-Ku, Nagoya, Aichi (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, 1-1-1 Hirate-cho, Kita-Ku, Nagoya, Aichi (Japan); Kataoka, Jun [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo (Japan); Kawachi, Naoki [Takasaki Advanced Radiation Research Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, 1233 Watanuki-Machi, Takasaki, Gunma (Japan)

    2016-10-11

    A feasibility study on an imaging technique of a therapeutic proton-beam trajectory using a gamma camera by measuring secondary electron bremsstrahlung (SEB) was performed by means of Monte Carlo simulations and a beam-irradiation experiment. From the simulation and experimental results, it was found that a significant amount of SEB yield exists between the beam-injection surface and the range position along the beam axis and the beam trajectory is clearly imaged by the SEB yield. It is concluded that the SEB imaging is a promising technique for monitoring of therapeutic proton-beam trajectories.

  14. Design of electron beam bending magnet system using three sector magnets for electron and photon therapy: a simulation approach

    International Nuclear Information System (INIS)

    Shahzad, A.A.; Bhoraskar, V.N.; Dhole, S.D.

    2013-01-01

    The 270 degree doubly achromatic beam bending magnet system using three sector magnets has been designed mainly for treating cancer and skin diseases. The main requirements of the design of three magnet system is to focus an electron beam having a spot size less than 3mm x 3mm, energy spread within 3% and divergence angle ≤ 3 mrad at the target. To achieve these parameters the simulation was carried out using Lorentz-3EM software. The beam spot, divergence angle and energy spread were observed with respect to the variation in angles of sector magnets and drift distances. From the simulated results, it has been optimized that all the three sector magnets has an angle of 62 degree and the drift distance 68 mm. It is also observed that at the 1637, 2425, 3278, 4165 and 5690 Amp-turn, the optimized design produces 3851, 5754, 7434, 9356 and 11425 Gauss of magnetic field at median plane require to bend 6, 9, 12, 15 and 18 MeV energy of electron respectively for electron therapy. The output parameters of the optimized design are energy spread 3%, divergence angle ∼ 3 mrad and spot size 2.8 mm. Moreover, for 6 MV and 15 MV photon therapy application, an electron beam of energy 6.5 MeV and 15.5 MeV extracted from magnet system and focussed on the Bremsstrahlung target. For the photon therapy the 1780, and 4456 amp-turn, an optimized design produces 4148 and 9682 Gauss of magnetic field at median plane require to bend 6.5 and 15.5 MeV energy of electron respectively, which further produces Bremsstrahlung in Tungsten target. (author)

  15. Study on intraoperative radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Uozumi, Akimasa

    1990-01-01

    Effects of a single large dose radiation on the brain of dogs were investigated for the purpose of determining the optimal dose and radiation field in intraoperative radiotherapy. The right parietal lobe of dogs (three groups, four dogs in each) were radiated at the dose of 30, 40 and 50 Gy respectively at the depth of 1.5 cm by 11 Nev electron beam with field size of 2 cm. CT and histopathological study were performed 2, 6, 12 and 24 months after radiation. L-hemiparesis developed 14 months after radiation in the 30 Gy group and 8 months in the 40 Gy group, 6 months in the 50 Gy group. All animals in the 40 Gy and 50 Gy groups died before 15 months of radiation. CT showed delayed radiation necrosis in all groups. Brain swelling and ventricular displacement in the radiated hemisphere and contralateral ventricular dilatation were depicted on plain CT. Diffuse heterogeneous contrast enhancement (CE) was observed on CE-CT. CT revealed disappearance of radiation necrosis in the 30 Gy group 24 months of radiation, suggesting that radiation necrosis may be dependent on the term after radiation. Histological findings of radiation necrosis were similar in all animals, and the vascular change preceding the parechymal necrosis was not observed. This supports the theory that the vascular alternation dose not play a major role in the production of radiation necrosis. The necrotic area grossly reflected the isodose curve and was observed in the radiation field with 15 to 20 Gy at the depth of 3 to 4.5 cm. Thus, the intraoperative radiotherapy should be planned on the basis of two such factors as electron beam energy and the field size, and the area out of the target should not be radiated at the dose of more than 15 Gy. The author believes that the information would contribute to safer and more effective application of intraoperative radiotherapy on malignant brain tumors. (J.P.N.) 63 refs

  16. Intraoperative Radiation Therapy: Characterization and Application

    Science.gov (United States)

    1989-03-01

    difficult to obtain. Notably, carcinomas of the pancreas, stomach, colon, and rectum, and sarcomas of soft tissue are prime candidates for IORT (2:131...Their pioneering efforts served as the basis for all my work. Mr. John Brohas of the AFIT Model Fabrication Shop aided my efforts considerably by... fabricated to set the collimator jaws to the required 10 cm x 10 cm aperture. The necessary parts are available from Varian. This will help eliminate errors

  17. INTRAOPERATIVE IRRADIATION OF THE CANINE PANCREAS - SHORT-TERM EFFECTS

    NARCIS (Netherlands)

    HEIJMANS, HJ; MEHTA, DM; KLEIBEUKER, JH; SLUITER, WJ; OLDHOFF, J; HOEKSTRA, HJ

    1993-01-01

    Intraoperative electron beam radiotherapy (IORT) is clinically used as a potential adjunctive treatment to surgery of locally advanced pancreatic and gastric cancer. The tolerance of the pancreas to IORT was studied in 15 adult beagles, divided in 3 groups of 5 beagles in which 25, 30 or 35 Gy IORT

  18. Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Michelle M., E-mail: mmkim@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Kanke, James E.; Zhang, Sean; Perkins, George H. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-07-01

    The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.

  19. Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies

    International Nuclear Information System (INIS)

    Wei Jikun; Sandison, George A; Hsi, W-C; Ringor, Michael; Lu Xiaoyi

    2006-01-01

    Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity

  20. Intraoperative transfusion practices in Europe

    DEFF Research Database (Denmark)

    Meier, J; Filipescu, D; Kozek-Langenecker, S

    2016-01-01

    BACKGROUND: Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (p......RBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. METHODS: We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month...... period in 2013. RESULTS: The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone...

  1. Tolerance of retroperitoneal structures to intraoperative radiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.; Terrill, R.

    1982-01-01

    In conjunction with the clinical development of intraoperative radiotherapy, a study was undertaken in dogs to define the tolerance of normal anatomic structures in the retroperitoneum to radiation delivered during operation. Twenty adult dogs were subjected to laparotomy and intraoperative 11 MeV electron irradiation in single doses ranging from 0.to 5000 rad. Animals were followed regularly with clinical observation, blood count, serum chemistries, pyelography, and angiography. Animals were sacrificed and autopsied at regular intervals up to 12 months following treatment to assess radiation-induced complications or tissue damage. Irradiation field in all dogs consisted of a 4 X 15 cm rectangle extending in the retroperitoneum from the level of the renal vessels to the bifurcation of aorta and vena cava. The field included aorta, vena cava, inferior portion of left kidney, and distal portion of left ureter. No complications or histologic changes occurred in any animal given doses of 2000 rad, with a follow-up in excess of 18 months. A dose of 3000 rad was well tolerated, except for left ureteral occlusion in one animal. Mild vascular fibrosis was present inthe aorta and vena cava, and significant ureteral fibrosis developed by six months after doses of 4000 or 5000 rad. All animals that received 5000 rad died of radiation-related complications, including ureteral obstruction and rectal perforation. It was concluded that major vessels tolerate intraoperative irradiation well up to and including 3000 rad and that no clinically significant vascular problems develop after 4000 and 5000 rad, although some fibrosis does occur. The ureter and kidney appear to be the most radiosensitive structures inthe retroperitoneum, showing progressive changes at 300 rad or greater and showing the potential for serious complications after doses of 4000 rad or more

  2. Versatile intraoperative MRI in neurosurgery and radiology.

    Science.gov (United States)

    Yrjänä, S K; Katisko, J P; Ojala, R O; Tervonen, O; Schiffbauer, H; Koivukangas, J

    2002-03-01

    Several models for the application of intra-operative magnetic resonance imaging (IMRI) have recently been reported, most of them unique. Two fundamental issues need to be addressed: optimal use of the scanner to ensure a wide base for research, development and clinical application, and an organisational model that facilitates such use. While in our setting the IMRI project was initiated by the neurosurgeons, the need for wider use of the facilities was recognised since the beginning of the planning phase in 1996. An organisational model was developed that allowed for development of neurosurgical applications, radiological imaging, and radiological interventions and for the research and development work of the vendor. A resistive 0.23 T MR scanner was installed in a dedicated operating room environment. Unique to this scanner is the ability to turn off the magnet, allowing for normal OR activities and devices, and to turn on the magnet as needed with a relatively short six-minute ramp up time. A staged surgical technique was perfected, allowing for transfer of data to the neuronavigator outside the scanner during surgery. In neurosurgery, IMRI was used as one part of a neuronavigational system that included ultrasound imaging, intra-operative cortical stimulation during awake procedures, electrocorticography and two neuronavigators. 34 neurosurgical cases included 27 brain tumour resections, 5 brain tumour biopsies, 1 extirpation of an arterio-venous malformation, and 1 haematoma evacuation. The scanner could also be used for normal clinical imaging where obese patients, children, claustophobic patients and postoperative control examinations were the major groups. The radiologists performed 110 interventions, including bone and abdominal biopsies, nerve root infiltrations and local pain therapies, with the optical needle tracking system under continuous MRI guidance. The organisational model allowed frequent use of the facilities for both neurosurgery and radiology

  3. Experimental study on intraoperative irradiation for pancreatic cancer

    International Nuclear Information System (INIS)

    Ito, Masanao; Asanuma, Yoshihiro; Shibata, Satoshi; Saitoh, Takashi; Koyama, Kenji; Watarai, Jiroh; Masuda, Hirotake

    1993-01-01

    For the treatment of pancreatic head cancer, pancreatoduodenectomy is followed by the intraoperative radiation therapy (IORT). The present dose adopted ranged 20 to 30 Gy; however, the dose is believed to be insufficient for local control of adenocarcinoma cells. In this study, high dose IORT was performed using rabbit, so histological and nutritional changes were evaluated. Rabbits were divided into three groups: 30 Gy, 50 Gy, and 80 Gy. The radiation was performed with electron focusing the base of cranial mesenteric artery (SMA in human). The rabbits were sacrificed at intervals ranging from immediately to 4 years after irradiation. The earliest evidence of histological changes was the loss of endothelium, although it was repaired within 1 week. Fragmentation and reduplication of internal elastic lamina were observed after 1 week; however, the degree was not dose dependent. Damages of the media was observed in 50 and 80 Gy groups. That is, focal degeneration of smooth muscle cell was demonstrated in 50 Gy group and medial necrosis in 80 Gy group. Degeneration of ganglion cells was observed and its severity was dose-dependent. In 80 Gy group, diarrhea occurred more frequently compared with the other groups and body weight loss could not recover within 4 weeks. It is concluded that, since necrosis of aortic media and marked degeneration of ganglion cells are inevitable in 80 Gy group, IORT dose should be increased within 50 Gy. (author)

  4. Practical use of a plastic scintillator for quality assurance of electron beam therapy.

    Science.gov (United States)

    Yogo, Katsunori; Tatsuno, Yuya; Tsuneda, Masato; Aono, Yuki; Mochizuki, Daiki; Fujisawa, Yoshiki; Matsushita, Akihiro; Ishigami, Minoru; Ishiyama, Hiromichi; Hayakawa, Kazushige

    2017-06-07

    Quality assurance (QA) of clinical electron beams is essential for performing accurate and safe radiation therapy. However, with advances in radiation therapy, QA has become increasingly labor-intensive and time-consuming. In this paper, we propose a tissue-equivalent plastic scintillator for quick and easy QA of clinical electron beams. The proposed tool comprises a plastic scintillator plate and a charge-coupled device camera that enable the scintillation light by electron beams to be recorded with high sensitivity and high spatial resolution. Further, the Cerenkov image is directly subtracted from the scintillation image to discriminate Cerenkov emissions and accurately measure the dose profiles of electron beams with high spatial resolution. Compared with conventional methods, discrepancies in the depth profile improved from 7% to 2% in the buildup region via subtractive corrections. Further, the output brightness showed good linearity with dose, good reproducibility (deviations below 1%), and dose rate independence (within 0.5%). The depth of 50% dose measured with the tool, an index of electron beam quality, was within  ±0.5 mm of that obtained with an ionization chamber. Lateral brightness profiles agreed with the lateral dose profiles to within 4% and no significant improvement was obtained using Cerenkov corrections. Field size agreed to within 0.5 mm with those obtained with ionization chamber. For clinical QA of electron boost treatment, a disk scintillator that mimics the shape of a patient's breast is applied. The brightness distribution and dose, calculated using a treatment planning system, was generally acceptable for clinical use, except in limited zones. Overall, the proposed plastic scintillator plate tool efficiently performs QA for electron beam therapy and enables simultaneous verification of output constancy, beam quality, depth, and lateral dose profiles during monthly QAs at lower doses of irradiation (small monitor units, MUs).

  5. Intraoperative ultrasound in colorectal surgery.

    Science.gov (United States)

    Greif, Franklin; Aranovich, David; Hananel, Nissim; Knizhnik, Mikhail; Belenky, Alexander

    2009-09-01

    To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique. (c) 2009 Wiley Periodicals, Inc.

  6. Intraoperative radiotherapy. Clinical experiences and results

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, F.A.; Santos, M. (Clinica Universitaria, Dept. of Oncology, Service of Radiotherapy, Pamplona (Spain)); Brady, L.W. (Hahnemann Univ., Dept. of Radiation Oncology, Philadelphia, PA (United States)) (eds.)

    1992-01-01

    This monograph reports on the largest clinical series to date in which intraoperative radiation therapy (IORT) has been used in mulitdisciplinary treatment programs for tumors of various sites and differing histological sybtype. It represents the product of 5 years' intensive work by physicians active at a leading European institution. The findings are supplemented by a thorough review of the data presented worldwide during the last two decades. The results in this book are meticulously presented and focus on the most important features of clinical research reports based on phase I-II studies (toxicity, local tumor control, and survival data). The tumor sites and histologies analyzed are: head and neck cancer, lung cancer, gastric cancer, pancreatic cancer, colorectal cancer, bladder cancer, gynecologic cancer, soft tissue sarcomas of the extremities, retroperitoneal and other central soft issue sarcomas, Ewing's sarcoma, osteosarcoma, and intracranial tumors. (orig./MG) With 60 figs.

  7. SU-F-T-79: Monte Carlo Investigation of Optimizing Parameters for Modulated Electron Arc Therapy

    International Nuclear Information System (INIS)

    Al Ashkar, E; Eraba, K; Imam, M; Eldib, A; Ma, C

    2016-01-01

    Purpose: Electron arc therapy provides excellent dose distributions for treating superficial tumors along curved surfaces. However this modality has not received widespread application due to the lack of needed advancement in electron beam delivery, accurate electron dose calculation and treatment plan optimization. The aim of the current work is to investigate possible parameters that can be optimized for electron arc (eARC) therapy. Methods: The MCBEAM code was used to generate phase space files for 6 and 12MeV electron beam energies from a Varian trilogy machine. An Electron Multi-leaf collimator eMLC of 2cm thickness positioned at 82 cm source collimated distance was used in the study. Dose distributions for electron arcs were calculated inside a cylindrical phantom using the MCSIM code. The Cylindrical phantom was constructed with 0.2cm voxels and a 15cm diameter. Electron arcs were delivered with two different approaches. The first approach was to deliver the arc as segments of very small field widths. In this approach we also tested the impact of the segment size and the arc increment angle. The second approach is to deliver the arc as a sum of large fields each covering the whole target as seen from the beam eye view. Results: In considering 90 % as the prescription isodose line, the first approach showed a region of buildup proceeding before the prescription zone. This build up is minimizing with the second approach neglecting need for bolus. The second approach also showed less x-ray contamination. In both approaches the variation of the segment size changed the size and location of the prescription isodose line. The optimization process for eARC could involve interplay between small and large segments to achieve desired coverage. Conclusion: An advanced modulation of eARCs will allow for tailored dose distribution for superficial curved target as with challenging scalp cases

  8. SU-F-T-79: Monte Carlo Investigation of Optimizing Parameters for Modulated Electron Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Al Ashkar, E; Eraba, K; Imam, M [Azhar university, Nasr City, Cairo (Egypt); Eldib, A; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Electron arc therapy provides excellent dose distributions for treating superficial tumors along curved surfaces. However this modality has not received widespread application due to the lack of needed advancement in electron beam delivery, accurate electron dose calculation and treatment plan optimization. The aim of the current work is to investigate possible parameters that can be optimized for electron arc (eARC) therapy. Methods: The MCBEAM code was used to generate phase space files for 6 and 12MeV electron beam energies from a Varian trilogy machine. An Electron Multi-leaf collimator eMLC of 2cm thickness positioned at 82 cm source collimated distance was used in the study. Dose distributions for electron arcs were calculated inside a cylindrical phantom using the MCSIM code. The Cylindrical phantom was constructed with 0.2cm voxels and a 15cm diameter. Electron arcs were delivered with two different approaches. The first approach was to deliver the arc as segments of very small field widths. In this approach we also tested the impact of the segment size and the arc increment angle. The second approach is to deliver the arc as a sum of large fields each covering the whole target as seen from the beam eye view. Results: In considering 90 % as the prescription isodose line, the first approach showed a region of buildup proceeding before the prescription zone. This build up is minimizing with the second approach neglecting need for bolus. The second approach also showed less x-ray contamination. In both approaches the variation of the segment size changed the size and location of the prescription isodose line. The optimization process for eARC could involve interplay between small and large segments to achieve desired coverage. Conclusion: An advanced modulation of eARCs will allow for tailored dose distribution for superficial curved target as with challenging scalp cases.

  9. Improvement of dose distributions in abutment regions of intensity modulated radiation therapy and electron fields

    International Nuclear Information System (INIS)

    Dogan, Nesrin; Leybovich, Leonid B.; Sethi, Anil; Emami, Bahman

    2002-01-01

    In recent years, intensity modulated radiation therapy (IMRT) is used to radiate tumors that are in close proximity to vital organs. Targets consisting of a deep-seated region followed by a superficial one may be treated with abutting photon and electron fields. However, no systematic study regarding matching of IMRT and electron beams was reported. In this work, a study of dose distributions in the abutment region between tomographic and step-and-shoot IMRT and electron fields was carried out. A method that significantly improves dose homogeneity between abutting tomographic IMRT and electron fields was developed and tested. In this method, a target region that is covered by IMRT was extended into the superficial target area by ∼2.0 cm. The length and shape of IMRT target extension was chosen such that high isodose lines bent away from the region treated by the electrons. This reduced the magnitude of hot spots caused by the 'bulging effect' of electron field penumbra. To account for the uncertainties in positioning of the IMRT and electron fields, electron field penumbra was modified using conventional (photon) multileaf collimator (MLC). The electron beam was delivered in two steps: half of the dose delivered with MLCs in retracted position and another half with MLCs extended to the edge of electron field that abuts tomographic IMRT field. The experimental testing of this method using film dosimetry has demonstrated that the magnitude of the hot spots was reduced from ∼45% to ∼5% of the prescription dose. When an error of ±1.5 mm in field positioning was introduced, the dose inhomogeneity in the abutment region did not exceed ±15% of the prescription dose. With step-and-shoot IMRT, the most homogeneous dose distribution was achieved when there was a 3 mm gap between the IMRT and electron fields

  10. Role of secondary low energy electrons in radiobiology and chemoradiation therapy of cancer

    Science.gov (United States)

    Sanche, Léon

    2009-05-01

    With the chemotherapeutic agent cisplatin bound to DNA, damage to the molecule by electrons of low and high energies increases by factors varying from 1.3 to 4.4. The enhancement in bond dissociation is triggered by modifications of the interaction of low energy electrons with DNA. From our understanding of the latter, the present Letter attempts to explain the basic radiation-damage mechanism responsible for the efficiency of the concomitant chemoradiation treatment of cancer. Such a basic comprehension of the direct effects of radiation may have implications in the design of new chemotherapeutic and radiosensitizing drugs, as well as in the development of more efficient protocols in chemoradiation therapy.

  11. Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Vazquez, Veronica; Marinetto, Eugenio [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Guerra, Pedro [Univ. Politecnica de Madrid (Spain). Dept. de Ingenieria Electronica; Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza (Spain); Valdivieso-Casique, Manlio Fabio [GMV SA, Madrid (Spain); Calvo, Felipe Angel [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Hospital General Univ. Gregorio Maranon, Madrid (Spain). Dept. de Oncologia; Univ. Complutense de Madrid (Spain). Facultad de Medicina; Alvarado-Vazquez, Eduardo [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Hospital General Univ. Gregorio Maranon, Madrid (Spain). Servicio de Oncologia Radioterapica; Sole, Claudio Vicente [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Instituto de Radiomedicina, Santiago (Chile). Service of Radiation Oncology; Vosburgh, Kirby Gannett [Harvard Medical School, Brigham and Women' s Hospital, Boston, MA (United States). Department of Radiology; Desco, Manuel; Pascau, Javier [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Univ. Carlos III de Madrid (Spain). Dept. de Bioingenieria e Ingenieria Aeroespacial; Centro de Investigacion Biomedica en Red de Salud Mental (CIBERSAM), Madrid (Spain)

    2017-10-01

    Intraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post-resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems (''O-arm'', a cone-beam CT [CBCT] system, and ''BodyTom'', a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) (''TrueBeam''). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.

  12. Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

    International Nuclear Information System (INIS)

    Garcia-Vazquez, Veronica; Marinetto, Eugenio; Guerra, Pedro; Valdivieso-Casique, Manlio Fabio; Calvo, Felipe Angel

    2017-01-01

    Intraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post-resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems (''O-arm'', a cone-beam CT [CBCT] system, and ''BodyTom'', a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) (''TrueBeam''). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.

  13. Intra-oral electron therapy for carcinoma of the oral cavity using transparent acrylic tubes

    International Nuclear Information System (INIS)

    Terashima, Hiromi; Nakata, Hajime; Yoshiura, Takao; Ogawa, Masato; Yoshida, Akio; Ikemura, Kunio

    1986-01-01

    Intra-oral electron therapy for carcinoma of the oral cavity is a well-established treatment modality. However, the conventional metallic tubes were inconvenient to use because the irradiation field had to be confirmed by a side mirror. We devised transparent acrylic tubes which enable the positioning easy by confirming the tumor and irradiation field directry. Seven cases of various intra-oral carcinomas were treated with these new transparent acrylic tubes and good results were obtained. (author)

  14. Post-chemoradiation intraoperative electron-beam radiation therapy boost in resected locally advanced rectal cancer: Long-term results focused on topographic pattern of locoregional relapse

    International Nuclear Information System (INIS)

    Sole, Claudio V.; Calvo, Felipe A.; Serrano, Javier; Valle, Emilio del; Rodriguez, Marcos; Muñoz-Calero, Alberto

    2014-01-01

    Background: Patients with locally advanced rectal cancer (LARC) have a dismal prognosis. We investigated outcomes and risk factors for locoregional recurrence (LRR) in patients treated with preoperative chemoradiotherapy (CRT), surgery and IOERT. Methods: A total of 335 patients with LARC [⩾cT3 93% and/or cN+ 69%) were studied. In multivariate analyses, risk factors for LRR, IFLR and OFLR were assessed. Results: Median follow-up was 72.6 months (range, 4–205). In multivariate analysis distal margin distance ⩽10 mm [HR 2.46, p = 0.03], R1 resection [HR 5.06, p = 0.02], tumor regression grade 1–2 [HR 2.63, p = 0.05] and tumor grade 3 [HR 7.79, p < 0.001] were associated with an increased risk of LRR. A risk model was generated to determine a prognostic index for individual patients with LARC. Conclusions: Overall results after multimodality treatment of LARC are promising. Classification of risk factors for LRR has contributed to propose a prognostic index that could allow us to guide risk-adapted tailored treatment

  15. Electron beam ion sources for use in second generation synchrotrons for medical particle therapy

    Science.gov (United States)

    Zschornack, G.; Ritter, E.; Schmidt, M.; Schwan, A.

    2014-02-01

    Cyclotrons and first generation synchrotrons are the commonly applied accelerators in medical particle therapy nowadays. Next generation accelerators such as Rapid Cycling Medical Synchrotrons (RCMS), direct drive accelerators, or dielectric wall accelerators have the potential to improve the existing accelerator techniques in this field. Innovative accelerator concepts for medical particle therapy can benefit from ion sources which meet their special requirements. In the present paper we report on measurements with a superconducting Electron Beam Ion Source, the Dresden EBIS-SC, under the aspect of application in combination with RCMS as a well proven technology. The measurements indicate that this ion source can offer significant advantages for medical particle therapy. We show that a superconducting EBIS can deliver ion pulses of medically relevant ions such as protons, C4 + and C6 + ions with intensities and frequencies required for RCMS [S. Peggs and T. Satogata, "A survey of Hadron therapy accelerator technology," in Proceedings of PAC07, BNL-79826- 2008-CP, Albuquerque, New Mexico, USA, 2007; A. Garonna, U. Amaldi et al., "Cyclinac medical accelerators using pulsed C6 +/H+_2 ion sources," in Proceedings of EBIST 2010, Stockholm, Sweden, July 2010]. Ion extraction spectra as well as individual ion pulses have been measured. For example, we report on the generation of proton pulses with up to 3 × 109 protons per pulse and with frequencies of up to 1000 Hz at electron beam currents of 600 mA.

  16. Dapsone Induced Methaemoglobinemia: Early Intraoperative Detection by Pulse Oximeter Desaturation

    Directory of Open Access Journals (Sweden)

    Mahmood Rafiq

    2008-01-01

    Case signifies the importance of knowledge of any preoperative drug intake and its anaesthetic implications. Also patients on dapsone therapy especially children should be monitored for methaemoglobin levels. Since children with immune thrombocy-topenic purpura are being treated with dapsone these days and many of these patients would be planned for splenectomy, monitoring of preoperative methaemoglobin levels and methaemoglobinemia as a cause of intraoperative pulse oximeter desaturation should be kept in mind.

  17. Monte Carlo based treatment planning for modulated electron beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Michael C. [Radiation Physics Division, Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States)]. E-mail: mclee@reyes.stanford.edu; Deng Jun; Li Jinsheng; Jiang, Steve B.; Ma, C.-M. [Radiation Physics Division, Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States)

    2001-08-01

    A Monte Carlo based treatment planning system for modulated electron radiation therapy (MERT) is presented. This new variation of intensity modulated radiation therapy (IMRT) utilizes an electron multileaf collimator (eMLC) to deliver non-uniform intensity maps at several electron energies. In this way, conformal dose distributions are delivered to irregular targets located a few centimetres below the surface while sparing deeper-lying normal anatomy. Planning for MERT begins with Monte Carlo generation of electron beamlets. Electrons are transported with proper in-air scattering and the dose is tallied in the phantom for each beamlet. An optimized beamlet plan may be calculated using inverse-planning methods. Step-and-shoot leaf sequences are generated for the intensity maps and dose distributions recalculated using Monte Carlo simulations. Here, scatter and leakage from the leaves are properly accounted for by transporting electrons through the eMLC geometry. The weights for the segments of the plan are re-optimized with the leaf positions fixed and bremsstrahlung leakage and electron scatter doses included. This optimization gives the final optimized plan. It is shown that a significant portion of the calculation time is spent transporting particles in the leaves. However, this is necessary since optimizing segment weights based on a model in which leaf transport is ignored results in an improperly optimized plan with overdosing of target and critical structures. A method of rapidly calculating the bremsstrahlung contribution is presented and shown to be an efficient solution to this problem. A homogeneous model target and a 2D breast plan are presented. The potential use of this tool in clinical planning is discussed. (author)

  18. Intra-operative radiation treatment of cancers

    International Nuclear Information System (INIS)

    Dubois, J.B.; Joyeux, H.; Solassol, C.; Pujol, H.

    1986-01-01

    Intra-operative radiation treatment (I.O.R.T.) is concerning the treatment either of an unresectable tumor or of tumor bed after complete excision of a primary tumor and its first draining lymph nodes. We describe X-ray and electrons techniques and we discuss the delivered doses according to experimental and clinical data. According to the residual disease (macroscopic or microscopic), to the healthy tissues in the target volume, and the histological type, single doses from 20 Gy to 40 Gy can be delivered. Our preliminary results are reported: 25 patients with resectable tumors of the cardia, the stomach and the pancreas, 5 patients with pelvic recurrences of colon and rectum carcinomas. Therapeutic results of the I.O.R.T. providing from the literature are discussed. The I.O.R.T. indications are defined as palliative (unresectable tumors) and curative (irradiation of tumor bed after complete excision of the tumor) [fr

  19. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  20. Dosimetry of a prototype retractable eMLC for fixed-beam electron therapy

    International Nuclear Information System (INIS)

    Hogstrom, Kenneth R.; Boyd, Robert A.; Antolak, John A.; Svatos, Michelle M.; Faddegon, Bruce A.; Rosenman, Julian G.

    2004-01-01

    An electron multileaf collimator (eMLC) has been designed that is unique in that it retracts to 37 cm from the isocenter [63-cm source-to-collimator distance (SCD)] and can be deployed to distances of 20 and 10 cm from the isocenter (80 and 90 cm SCD, respectively). It is expected to be capable of arc therapy at 63 cm SCD; isocentric, fixed-beam therapy at 80 cm SCD; and source-to-surface distance (SSD), fixed-beam therapy at 90 cm SCD. In all positions, its leaves could be used for unmodulated or intensity-modulated therapy. Our goal in the present work is to describe the general characteristics of the eMLC and to demonstrate that its leakage characteristics and dosimetry are adequate for SSD, fixed-beam therapy as an alternative to Cerrobend cutouts with applicators once the prototype's leaves are motorized. Our eMLC data showed interleaf electron leakage at 15 MeV to be less than 0.1% based on a 0.0025 cm manufacturing tolerance, and lateral electron leakage at 5 and 15 MeV to be less than 2%. X-ray leakage through the leaves was 1.6% at 15 MeV. Our data showed that beam penumbra was independent of direction and leaf position. The dosimetric properties of square fields formed by the eMLC were very consistent with those formed by Cerrobend inserts in the 20x20 cm 2 applicator. Output factors exhibited similar field-size dependence. Airgap factors exhibited almost identical field-size dependence at two SSDs (105 and 110 cm), consistent with the common assumption that airgap factors are applicator independent. Percent depth-dose curves were similar, but showed variations up to 3% in the buildup region. The pencil-beam algorithm (PBA) fit measured data from the eMLC and applicator-cutout systems equally well, and the resulting two-dimensional (2-D) dose distributions, as predicted by the PBA, agreed well at common airgap distance. Simulating patient setups for breast and head and neck treatments showed that almost all fields could be treated using similar SSDs as

  1. Estimation of four-dimensional dose distribution using electronic portal imaging device in radiation therapy

    International Nuclear Information System (INIS)

    Mizoguchi, Asumi; Arimura, Hidetaka; Shioyama, Yoshiyuki

    2013-01-01

    We are developing a method to evaluate four-dimensional radiation dose distribution in a patient body based upon the animated image of EPID (electronic portal imaging device) which is an image of beam-direction at the irradiation. In the first place, we have obtained the image of the dose which is emitted from patient body at therapy planning using therapy planning CT image and dose evaluation algorism. In the second place, we have estimated the emission dose image at the irradiation using EPID animated image which is obtained at the irradiation. In the third place, we have got an affine transformation matrix including respiratory movement in the body by performing linear registration on the emission dose image at therapy planning to get the one at the irradiation. In the fourth place, we have applied the affine transformation matrix on the therapy planning CT image and estimated the CT image 'at irradiation'. Finally we have evaluated four-dimensional dose distribution by calculating dose distribution in the CT image 'at irradiation' which has been estimated for each frame of the EPID animated-image. This scheme may be useful for evaluating therapy results and risk management. (author)

  2. The impact of an electronic monitoring and reminder device on patient compliance with antihypertensive therapy

    DEFF Research Database (Denmark)

    Christensen, Arne; Christrup, Lona Louring; Fabricius, Paul Erik

    2010-01-01

    . In the first half of the study, patients using the device reported 91% compliance versus 85% in the control group. This difference diminished after crossover (88 versus 86%). BP was not affected. Electronic monitoring data on compliance revealed taking, dosing and timing compliance between 45 and 52% in study...... to be effective in improving patient compliance to some extent, but the combined effect has not been documented. OBJECTIVE: To assess the impact of an electronic reminder and monitoring device on patient compliance and BP control. METHODS: All patients received medical treatment with telmisartan once daily...... and were randomized to either electronic compliance monitoring with a reminder and monitoring device or standard therapy for 6 months. Both groups were crossed over after 6 months. Intervention effectiveness was assessed using self-reported compliance and BP. RESULTS: Data from 398 patients were analysed...

  3. Electron arc therapy: Influence of heterogeneities on dose to blood-forming organs

    International Nuclear Information System (INIS)

    Leavitt, D.D.; Gibbs, F.A.; Moeller, J.H.

    1986-01-01

    Electron arc therapy has been used successfully to treat extended chest wall surfaces after mastectomy. Treatment is frequently given simultaneously with chemotherapy. Although the primary electron arc treatment volume consists only of the chest wall and mediastinum, dose is accumulated at the isocenter of rotation due to the photon contamination of the arcing electron beam. Additionally, higher energy electron fields which are occasionally used over segments of the arc may contribute to the dose at isocenter if the electron range has been extended due to passage through a low-density heterogeneity such as lung. In some patient setups, the isocenter may intersect blood-forming organs, such as the vertebral bodies. Thermoluminescent dosimetry has been used to measure the dose at isocenter for the following setups: polystyrene phantom, polystyrene phantom covered by 1-cm-thick lead cast, polystyrene phantom with cork insert to simulate lung, and phantom plus cork insert plus lead cast. For the 9-MeV treatment mode, dose at isocenter per 90 0 of arc (as a percentage of maximum tumor dose) is as follows: phantom, 6.5%; phantom plus lead, 5%; phantom plus cork, 8%; and phantom plus cork plus lead, 6%. These values must be scaled by the size of the arc to estimate dose at isocenter in actual treatments. Computer calculation showed good agreement with these measured values, indicating that the computerized treatment plans can be used as a predictor of electron arc dose to blood-forming organs

  4. Adherence to HAART therapy measured by electronic monitoring in newly diagnosed HIV patients in Botswana.

    Science.gov (United States)

    Vriesendorp, Reinout; Cohen, Adam; Kristanto, Paulus; Vrijens, Bernard; Rakesh, Pande; Anand, Bene; Iwebor, Henry Uchechukwaka; Stiekema, Jacobus

    2007-12-01

    This pilot study was designed to evaluate the feasibility and benefits of electronic adherence monitoring of antiretroviral medications in HIV patients who recently started Highly Active Anti Retroviral Therapy (HAART) in Francistown, Botswana and to compare this with self-reporting. Dosing histories were compiled electronically using Micro Electro Mechanical Systems (MEMS) monitors to evaluate adherence to prescribed therapies. Thirty patients enrolled in the antiretroviral treatment program were monitored over 6 weeks. These patients were all antiretroviral (ARV) naïve. After each visit (mean three times) to the pharmacy, the data compiled by the monitors were downloaded. Electronic monitoring of adherence was compared to patient self-reports of adherence. The mean individual medication adherence level measured with the electronic device was 85% (range 21-100%). The mean adherence level measured by means of self-reporting was 98% (range 70-100%). Medication prescribed on a once-a-day dose base was associated with a higher adherence level (97.9% for efavirenz) compared with a twice-a-day regimen (88.4% for Lamivudine/Zidovudine). It is feasible to assess treatment adherence of patients living in a low resource setting on HAART by using electronic monitors. Adherence, even in the early stages of treatment, appears to be insufficient in some patients and may be below the level required for continuous inhibition of viral replication. This approach may lead to improved targeting of counselling about their medication intake of such patients in order to prevent occurrence of resistant viral strains due to inadequate inhibition of viral replication. In this pilot study a significant difference between the data recorded through the electronic monitors and those provided by self-reporting was observed.

  5. Postmastectomy Electron Beam Chest Wall Irradiation in Women With Breast Cancer: A Clinical Step Toward Conformal Electron Therapy

    International Nuclear Information System (INIS)

    Kirova, Youlia M.; Campana, Francois; Fournier-Bidoz, Nathalie; Stilhart, Anne; Dendale, Remi; Bollet, Marc A.; Fourquet, Alain

    2007-01-01

    Purpose: Electron beam radiotherapy of the chest wall with or without lymph node irradiation has been used at the Institut Curie for >20 years. The purpose of this report was to show the latest improvements of our technique developed to avoid hot spots and improve the homogeneity. Methods and Materials: The study was split into two parts. A new electron irradiation technique was designed and compared with the standard one (dosimetric study). The dose distributions were calculated using our treatment planning software ISIS (Technologie Diffusion). The dose calculation was performed using the same calculation parameters for the new and standard techniques. Next, the early skin toxicity of our new technique was evaluated prospectively in the first 25 patients using Radiation Therapy Oncology Group criteria (clinical study). Results: The maximal dose found on the five slices was 53.4 ± 1.1 Gy for the new technique and 59.1 ± 2.3 Gy for the standard technique. The hot spots of the standard technique plans were situated at the overlap between the internal mammary chain and chest wall fields. The use of one unique field that included both chest wall and internal mammary chain volumes solved the problem of junction. To date, 25 patients have been treated with the new technique. Of these patients, 12% developed Grade 0, 48% Grade 1, 32% Grade 2, and 8% Grade 3 toxicity. Conclusions: This report describes an improvement in the standard postmastectomy electron beam technique of the chest wall. This new technique provides improved target homogeneity and conformality compared with the standard technique. This treatment was well tolerated, with a low rate of early toxicity events

  6. Knowledge and Perceptions about Nicotine, Nicotine Replacement Therapies and Electronic Cigarettes among Healthcare Professionals in Greece

    Directory of Open Access Journals (Sweden)

    Anastasia Moysidou

    2016-05-01

    Full Text Available Introduction. The purpose of this study was to evaluate the knowledge and perceptions of Greek healthcare professionals about nicotine, nicotine replacement therapies and electronic cigarettes. Methods. An online survey was performed, in which physicians and nurses working in private and public healthcare sectors in Athens-Greece were asked to participate through email invitations. A knowledge score was calculated by scoring the correct answers to specific questions with 1 point. Results. A total of 262 healthcare professionals were included to the analysis. Most had daily contact with smokers in their working environment. About half of them considered that nicotine has an extremely or very important contribution to smoking-related disease. More than 30% considered nicotine replacement therapies equally or more addictive than smoking, 76.7% overestimated their smoking cessation efficacy and only 21.0% would recommend them as long-term smoking substitutes. For electronic cigarettes, 45.0% considered them equally or more addictive than smoking and 24.4% equally or more harmful than tobacco cigarettes. Additionally, 35.5% thought they involve combustion while the majority responded that nicotine in electronic cigarettes is synthetically produced. Only 14.5% knew about the pending European regulation, but 33.2% have recommended them to smokers in the past. Still, more than 40% would not recommend electronic cigarettes to smokers unwilling or unable to quit smoking with currently approved medications. Cardiologists and respiratory physicians, who are responsible for smoking cessation therapy in Greece, were even more reluctant to recommend electronic cigarettes to this subpopulation of smokers compared to all other participants. The knowledge score of the whole study sample was 7.7 (SD: 2.4 out of a maximum score of 16. Higher score was associated with specific physician specialties. Conclusions. Greek healthcare professionals appear to overestimate

  7. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  8. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    International Nuclear Information System (INIS)

    Kosunen, A.

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?) water air , in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in 60 Co gamma beams. In photon beam dosimetry (S I ?) water air can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation). To improve the accuracy

  9. Cancer therapy using non-thermal atmospheric pressure plasma with ultra-high electron density

    International Nuclear Information System (INIS)

    Tanaka, Hiromasa; Mizuno, Masaaki; Toyokuni, Shinya; Maruyama, Shoichi; Kodera, Yasuhiro; Terasaki, Hiroko; Adachi, Tetsuo; Kato, Masashi; Kikkawa, Fumitaka; Hori, Masaru

    2015-01-01

    Cancer therapy using non-thermal atmospheric pressure plasma is a big challenge in plasma medicine. Reactive species generated from plasma are key factors for treating cancer cells, and thus, non-thermal atmospheric pressure plasma with high electron density has been developed and applied for cancer treatment. Various cancer cell lines have been treated with plasma, and non-thermal atmospheric plasma clearly has anti-tumor effects. Recent innovative studies suggest that plasma can both directly and indirectly affect cells and tissues, and this observation has widened the range of applications. Thus, cancer therapy using non-thermal atmospheric pressure plasma is promising. Animal experiments and understanding the mode of action are essential for clinical application in the future. A new academic field that combines plasma science, the biology of free radicals, and systems biology will be established

  10. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. RESULTS: The overall response rate was 95% with a complete cutaneous response......PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... or a very good partial response rate (response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  11. Cancer therapy using non-thermal atmospheric pressure plasma with ultra-high electron density

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiromasa [Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Center for Advanced Medicine and Clinical Research, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Mizuno, Masaaki [Center for Advanced Medicine and Clinical Research, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Toyokuni, Shinya [Department of Pathology and Biological Responses, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Maruyama, Shoichi [Department of Nephrology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Kodera, Yasuhiro [Department of Gastroenterological Surgery (Surgery II), Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Terasaki, Hiroko [Department of Ophthalmology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Adachi, Tetsuo [Laboratory of Clinical Pharmaceutics, Gifu Pharmaceutical University, 501-1196 Gifu (Japan); Kato, Masashi [Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Kikkawa, Fumitaka [Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Hori, Masaru [Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2015-12-15

    Cancer therapy using non-thermal atmospheric pressure plasma is a big challenge in plasma medicine. Reactive species generated from plasma are key factors for treating cancer cells, and thus, non-thermal atmospheric pressure plasma with high electron density has been developed and applied for cancer treatment. Various cancer cell lines have been treated with plasma, and non-thermal atmospheric plasma clearly has anti-tumor effects. Recent innovative studies suggest that plasma can both directly and indirectly affect cells and tissues, and this observation has widened the range of applications. Thus, cancer therapy using non-thermal atmospheric pressure plasma is promising. Animal experiments and understanding the mode of action are essential for clinical application in the future. A new academic field that combines plasma science, the biology of free radicals, and systems biology will be established.

  12. Physics-based shape matching for intraoperative image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Suwelack, Stefan, E-mail: suwelack@kit.edu; Röhl, Sebastian; Bodenstedt, Sebastian; Reichard, Daniel; Dillmann, Rüdiger; Speidel, Stefanie [Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology, Adenauerring 2, Karlsruhe 76131 (Germany); Santos, Thiago dos; Maier-Hein, Lena [Computer-assisted Interventions, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120 (Germany); Wagner, Martin; Wünscher, Josephine; Kenngott, Hannes; Müller, Beat P. [General, Visceral and Transplantation Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 110, Heidelberg 69120 (Germany)

    2014-11-01

    method is able to accurately match partial surfaces. Finally, a phantom experiment demonstrates how the method can be combined with stereo endoscopic imaging to provide nonrigid registration during laparoscopic interventions. Conclusions: The PBSM approach for surface matching is fast, robust, and accurate. As the technique is based on a preoperative volumetric FE model, it naturally recovers the position of volumetric structures (e.g., tumors and vessels). It cannot only be used to recover soft-tissue deformations from intraoperative surface models but can also be combined with landmark data from volumetric imaging. In addition to applications in laparoscopic surgery, the method might prove useful in other areas that require soft-tissue registration from sparse intraoperative sensor data (e.g., radiation therapy)

  13. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  14. Minimalism through intraoperative functional mapping.

    Science.gov (United States)

    Berger, M S

    1996-01-01

    Intraoperative stimulation mapping may be used to avoid unnecessary risk to functional regions subserving language and sensori-motor pathways. Based on the data presented here, language localization is variable in the entire population, with only certainty existing for the inferior frontal region responsible for motor speech. Anatomical landmarks such as the anterior temporal tip for temporal lobe language sites and the posterior aspect of the lateral sphenoid wing for the frontal lobe language zones are unreliable in avoiding postoperative aphasias. Thus, individual mapping to identify essential language sites has the greatest likelihood of avoiding permanent deficits in naming, reading, and motor speech. In a similar approach, motor and sensory pathways from the cortex and underlying white matter may be reliably stimulated and mapped in both awake and asleep patients. Although these techniques require an additional operative time and equipment nominally priced, the result is often gratifying, as postoperative morbidity has been greatly reduced in the process of incorporating these surgical strategies. The patients quality of life is improved in terms of seizure control, with or without antiepileptic drugs. This avoids having to perform a second costly operative procedure, which is routinely done when extraoperative stimulation and recording is done via subdural grids. In addition, an aggressive tumor resection at the initial operation lengthens the time to tumor recurrence and often obviates the need for a subsequent reoperation. Thus, intraoperative functional mapping may be best alluded to as a surgical technique that results in "minimalism in the long term".

  15. Laser-Driven Very High Energy Electron/Photon Beam Radiation Therapy in Conjunction with a Robotic System

    Directory of Open Access Journals (Sweden)

    Kazuhisa Nakajima

    2014-12-01

    Full Text Available We present a new external-beam radiation therapy system using very-high-energy (VHE electron/photon beams generated by a centimeter-scale laser plasma accelerator built in a robotic system. Most types of external-beam radiation therapy are delivered using a machine called a medical linear accelerator driven by radio frequency (RF power amplifiers, producing electron beams with an energy range of 6–20 MeV, in conjunction with modern radiation therapy technologies for effective shaping of three-dimensional dose distributions and spatially accurate dose delivery with imaging verification. However, the limited penetration depth and low quality of the transverse penumbra at such electron beams delivered from the present RF linear accelerators prevent the implementation of advanced modalities in current cancer treatments. These drawbacks can be overcome if the electron energy is increased to above 50 MeV. To overcome the disadvantages of the present RF-based medical accelerators, harnessing recent advancement of laser-driven plasma accelerators capable of producing 1-GeV electron beams in a 1-cm gas cell, we propose a new embodiment of the external-beam radiation therapy robotic system delivering very high-energy electron/photon beams with an energy of 50–250 MeV; it is more compact, less expensive, and has a simpler operation and higher performance in comparison with the current radiation therapy system.

  16. Total skin electron therapy as treatment for epitheliotropic lymphoma in a dog.

    Science.gov (United States)

    Santoro, Domenico; Kubicek, Lyndsay; Lu, Bo; Craft, William; Conway, Julia

    2017-04-01

    Mycosis fungoides (MF) is an uncommon cutaneous neoplasm in dogs. Treatment options are limited. Total skin electron therapy (TSET) has been suggested as a possible therapy for canine MF. To describe the use of TSET as palliative treatment for MF in a dog. An adult dog, previously diagnosed with nonepidermolytic ichthyosis, was presented with generalized erythroderma, alopecia and erosions. Histopathology revealed a densely cellular, well-demarcated, unencapsulated infiltrate extending from the epidermis to the mid-dermis compatible with MF. The infiltrate exhibited epitheliotropism multifocally for the epidermis, infundibula and adnexa. Due to a lack of response to chemotherapy, TSET was elected. Six megavoltage electrons were delivered using a 21EX Varian linear accelerator. A dose of 6 Gy was delivered to the skin surface and a 100 cm skin to surface distance was used for dog setup. The treatment time for the cranial half treatment was 3 h. The treatment was divided in two sessions (cranial and caudal halves of the body) 15 days apart. Clinical and histopathological complete remission was achieved and the dog was kept in remission with no additional treatments for 19 months before relapse and development of Sézary syndrome. To the best of the authors' knowledge, this is the first case reporting the use of TSET for medically refractory canine MF with post treatment follow-up. This case suggests that the use of TSET may be an effective palliative treatment for canine MF. © 2017 ESVD and ACVD.

  17. Monte Carlo based simulation of LIAC intraoperative radiotherapy accelerator along with beam shaper applicator

    Directory of Open Access Journals (Sweden)

    N Heidarloo

    2017-08-01

    Full Text Available Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric characteristics of the electron beam produced by LIAC intraoperative radiotherapy accelerator in conjunction with this applicator have been evaluated through Monte Carlo simulation by MCNP code. The results showed that the electron beam produced by the beam shaper applicator would have the desirable dosimetric characteristics, so that the mentioned applicator can be considered for clinical purposes. Furthermore, the good agreement between the results of simulation and practical dosimetry, confirms the applicability of Monte Carlo method in determining the dosimetric parameters of electron beam  intraoperative radiotherapy

  18. Electron Paramagnetic Resonance pO2 Image Tumor Oxygen-Guided Radiation Therapy Optimization.

    Science.gov (United States)

    Epel, Boris; Maggio, Matt; Pelizzari, Charles; Halpern, Howard J

    2017-01-01

    Modern standards for radiation treatment do not take into account tumor oxygenation for radiation treatment planning. Strong correlation between tumor oxygenation and radiation treatment success suggests that oxygen-guided radiation therapy (OGRT) may be a promising enhancement of cancer radiation treatment. We have developed an OGRT protocol for rodents. Electron paramagnetic resonance (EPR) imaging is used for recording oxygen maps with high spatial resolution and excellent accuracy better than 1 torr. Radiation is delivered with an animal intensity modulated radiation therapy (IMRT) XRAD225Cx micro-CT/ therapy system. The radiation plan is delivered in two steps. First, a uniform 15% tumor control dose (TCD 15 ) is delivered to the whole tumor. In the second step, an additional booster dose amounting to the difference between TCD 98 and TCD 15 is delivered to radio-resistant, hypoxic tumor regions. Delivery of the booster dose is performed using a multiport conformal beam protocol. For radiation beam shaping we used individual radiation blocks 3D-printed from tungsten infused ABS polymer. Calculation of beam geometry and the production of blocks is performed next to the EPR imager, immediately after oxygen imaging. Preliminary results demonstrate the sub-millimeter precision of the radiation delivery and high dose accuracy. The efficacy of the radiation treatment is currently being tested on syngeneic FSa fibrosarcoma tumors grown in the legs of C3H mice.

  19. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields

    International Nuclear Information System (INIS)

    Pavon, Ester Carrasco; Sanchez-Doblado, Francisco; Leal, Antonio; Capote, Roberto; Lagares, Juan Ignacio; Perucha, Maria; Arrans, Rafael

    2003-01-01

    Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm 2 electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm 2 field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm 2 open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R 50 , R 80 , R 100 , R p , E 0 ) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD = 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13deg at SSD 100 cm to more than 30deg at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC

  20. Intraoperative closure of infant multiple muscular ventricular septal defects with Amplatzer occluder

    International Nuclear Information System (INIS)

    Liu Jinfen; Gao Wei; Zhu Zhongqun; Chen Huiwen; Zhang Yuqi

    2005-01-01

    Objective: To report the preliminary experience of intraoperative hybrid therapy for closure of multiple muscular ventricular septal defects (VSD) in a small infant. Methods: After median sternotomy, a AGA Amplatzer occluder was introduced through right ventricular surface to close 2 muscular ventricular septal defects under transesophageal echocardiographic guidance. Results: The infant survived after the treatment without residual shunting, and rehabilitated rapidly. Conclusions: Intraoperative hybrid therapy with combined surgical technique and interventional procedure for closure of multiple muscular VSD in small infant is a safe and effective method. (authors)

  1. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  2. On mixed electron-photon radiation therapy optimization using the column generation approach.

    Science.gov (United States)

    Renaud, Marc-André; Serban, Monica; Seuntjens, Jan

    2017-08-01

    Despite considerable increase in the number of degrees of freedom handled by recent radiotherapy optimisation algorithms, treatments are still typically delivered using a single modality. Column generation is an iterative method for solving large optimisation problems. It is well suited for mixed-modality (e.g., photon-electron) optimisation as the aperture shaping and modality selection problem can be solved rapidly, and the performance of the algorithm scales favourably with increasing degrees of freedom. We demonstrate that the column generation method applied to mixed photon-electron planning can efficiently generate treatment plans and investigate its behaviour under different aperture addition schemes. Column generation was applied to the problem of mixed-modality treatment planning for a chest wall case and a leg sarcoma case. 6 MV beamlets (100 cm SAD) were generated for the photon components along with 5 energies for electron beamlets (6, 9, 12, 16 and 20 MeV), simulated as shortened-SAD (80 cm) beams collimated with a photon MLC. For the chest wall case, IMRT-only, modulated electron radiation therapy (MERT)-only, and mixed electron-photon (MBRT) treatment plans were created using the same planning criteria. For the sarcoma case, MBRT and MERT plans were created to study the behaviour of the algorithm under two different sets of planning criteria designed to favour specific modalities. Finally, the efficiency and plan quality of four different aperture addition schemes was analysed by creating chest wall MBRT treatment plans which incorporate more than a single aperture per iteration of the column generation loop based on a heuristic aperture ranking scheme. MBRT plans produced superior target coverage and homogeneity relative to IMRT and MERT plans created using the same optimisation criteria, all the while preserving the normal tissue-sparing advantages of electron therapy. Adjusting the planning criteria to favour a specific modality in the sarcoma

  3. A unifying probabilistic Bayesian approach to derive electron density from MRI for radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Gudur, Madhu Sudhan Reddy; Hara, Wendy; Le, Quynh-Thu; Wang, Lei; Xing, Lei; Li, Ruijiang

    2014-01-01

    MRI significantly improves the accuracy and reliability of target delineation in radiation therapy for certain tumors due to its superior soft tissue contrast compared to CT. A treatment planning process with MRI as the sole imaging modality will eliminate systematic CT/MRI co-registration errors, reduce cost and radiation exposure, and simplify clinical workflow. However, MRI lacks the key electron density information necessary for accurate dose calculation and generating reference images for patient setup. The purpose of this work is to develop a unifying method to derive electron density from standard T1-weighted MRI. We propose to combine both intensity and geometry information into a unifying probabilistic Bayesian framework for electron density mapping. For each voxel, we compute two conditional probability density functions (PDFs) of electron density given its: (1) T1-weighted MRI intensity, and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of the atlas and test patient. The two conditional PDFs containing intensity and geometry information are combined into a unifying posterior PDF, whose mean value corresponds to the optimal electron density value under the mean-square error criterion. We evaluated the algorithm’s accuracy of electron density mapping and its ability to detect bone in the head for eight patients, using an additional patient as the atlas or template. Mean absolute HU error between the estimated and true CT, as well as receiver operating characteristics for bone detection (HU > 200) were calculated. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 126, compared with 139 for deformable registration (p = 2  ×  10 −4 ), 283 for the intensity approach (p = 2  ×  10 −6 ) and 282

  4. On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy

    International Nuclear Information System (INIS)

    Zhe Chen; Agostinelli, Alfred; Nath, Ravinder

    1998-01-01

    The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to 120cmx200cm). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated that an additional error of up to 4% could be introduced if the unshielded cable

  5. A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy

    International Nuclear Information System (INIS)

    Lee, Jung Woo; Kim, Jeong Man

    1996-01-01

    We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100 cm to 120 cm with 5 cm step and with different energies(6 MeV, 9 MeV, 12 MeV, 16 MeV, 20 MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100 cm to 120 cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  6. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  7. Intraoperative radiotherapy in breast cancer: literature review

    International Nuclear Information System (INIS)

    Alfaro Hidalgo, Sabrina A.

    2013-01-01

    A literature review was performed on intraoperative radiotherapy of breast cancer. The strength and attractiveness is established of techniques of partial irradiation in the treatment of breast cancer. The benefit is originated to restrict the area immediate of radiotherapy to the tumor bed or quadrant index and identifying the benefit of being applied during the radiotherapy while surgical lumpectomy. The impact of local recurrence has been established using intraoperative radiotherapy. The advantages of intraoperative radiotherapy was compared in the management of the conservative surgery in early stages of breast cancer with external radiotherapy. Different methods of intraoperative radiotherapy have been compared and individual impact on local recurrence ranges. Intraoperative radiotherapy has had many advantages: radiobiological, technical, clinical, psychological and economical in the handling of conservative surgery in early stages of breast cancer, compared with external radiotherapy [es

  8. Perspectives in Intraoperative Diagnostics of Human Gliomas

    Directory of Open Access Journals (Sweden)

    O. Tyurikova

    2015-01-01

    Full Text Available Amongst large a variety of oncological diseases, malignant gliomas represent one of the most severe types of tumors. They are also the most common type of the brain tumors and account for over half of the astrocytic tumors. According to different sources, the average life expectancy of patients with various glioblastomas varies between 10 and 12 months and that of patients with anaplastic astrocytic tumors between 20 and 24 months. Therefore, studies of the physiology of transformed glial cells are critical for the development of treatment methods. Modern medical approaches offer complex procedures, including the microsurgical tumor removal, radiotherapy, and chemotherapy, supplemented with photodynamic therapy and immunotherapy. The most radical of them is surgical resection, which allows removing the largest part of the tumor, reduces the intracranial hypertension, and minimizes the degree of neurological deficit. However, complete removal of the tumor remains impossible. The main limitations are insufficient visualization of glioma boundaries, due to its infiltrative growth, and the necessity to preserve healthy tissue. This review is devoted to the description of advantages and disadvantages of modern intraoperative diagnostics of human gliomas and highlights potential perspectives for development of their treatment.

  9. Practicality of intraoperative teamwork assessments.

    Science.gov (United States)

    Phitayakorn, Roy; Minehart, Rebecca; Pian-Smith, May C M; Hemingway, Maureen W; Milosh-Zinkus, Tanya; Oriol-Morway, Danika; Petrusa, Emil

    2014-07-01

    High-quality teamwork among operating room (OR) professionals is a key to efficient and safe practice. Quantification of teamwork facilitates feedback, assessment, and improvement. Several valid and reliable instruments are available for assessing separate OR disciplines and teams. We sought to determine the most feasible approach for routine documentation of teamwork in in-situ OR simulations. We compared rater agreement, hypothetical training costs, and feasibility ratings from five clinicians and two nonclinicians with instruments for assessment of separate OR groups and teams. Five teams of anesthesia or surgery residents and OR nurses (RN) or surgical technicians were videotaped in simulations of an epigastric hernia repair where the patient develops malignant hyperthermia. Two anesthesiologists, one OR clinical RN specialist, one educational psychologist, one simulation specialist, and one general surgeon discussed and then independently completed Anesthesiologists' Non-Technical Skills, Non-Technical Skills for Surgeons, Scrub Practitioners' List of Intraoperative Non-Technical Skills, and Observational Teamwork Assessment for Surgery forms to rate nontechnical performance of anesthesiologists, surgeons, nurses, technicians, and the whole team. Intraclass correlations of agreement ranged from 0.17-0.85. Clinicians' agreements were not different from nonclinicians'. Published rater training was 4 h for Anesthesiologists' Non-Technical Skills and Scrub Practitioners' List of Intraoperative Non-Technical Skills, 2.5 h for Non-Technical Skills for Surgeons, and 15.5 h for Observational Teamwork Assessment for Surgery. Estimated costs to train one rater to use all instruments ranged from $442 for a simulation specialist to $6006 for a general surgeon. Additional training is needed to achieve higher levels of agreement; however, costs may be prohibitive. The most cost-effective model for real-time OR teamwork assessment may be to use a simulation technician

  10. Output calculation of electron therapy at extended SSD using an improved LBR method

    Energy Technology Data Exchange (ETDEWEB)

    Alkhatib, Hassaan A.; Gebreamlak, Wondesen T., E-mail: wondtassew@gmail.com; Wright, Ben W.; Neglia, William J. [South Carolina Oncology Associates, Columbia, South Carolina 29210 (United States); Tedeschi, David J. [Department of Physics and Astronomy, University of South Carolina, Columbia, South Carolina 29208 (United States); Mihailidis, Dimitris [CAMC Cancer Center and Alliance Oncology, Charleston, West Virginia 25304 (United States); Sobash, Philip T. [The Medical University of South Carolina, Charleston, South Carolina 29425 (United States); Fontenot, Jonas D. [Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana 70809 (United States)

    2015-02-15

    calculate the output factor of electron therapy at extended SSD. The percentage difference between the calculated and the measured output factors of irregularly shaped cutouts in a clinical useful SSD region was within 2%. Similar results were obtained for all available electron energies of both Varian 2100C and ELEKTA Synergy machines.

  11. Can we trust intraoperative culture results in nonunions?

    Science.gov (United States)

    Palmer, Michael P; Altman, Daniel T; Altman, Gregory T; Sewecke, Jeffrey J; Ehrlich, Garth D; Hu, Fen Z; Nistico, Laura; Melton-Kreft, Rachel; Gause, Trent M; Costerton, John W

    2014-07-01

    To identify the presence of bacterial biofilms in nonunions comparing molecular techniques (multiplex polymerase chain reaction and mass spectrometry, fluorescent in situ hybridization) with routine intraoperative cultures. Thirty-four patients with nonunions were scheduled for surgery and enrolled in this ongoing prospective study. Intraoperative specimens were collected from removed implants, surrounding tissue membrane, and local soft tissue followed by standard culture analysis, Ibis's second generation molecular diagnostics (Ibis Biosystems), and bacterial 16S rRNA-based fluorescence in situ hybridization (FISH). Confocal microscopy was used to visualize the tissue specimens reacted with the FISH probes, which were chosen based on the Ibis analysis. Thirty-four patient encounters were analyzed. Eight were diagnosed as infected nonunions by positive intraoperative culture results. Ibis confirmed the presence of bacteria in all 8 samples. Ibis identified bacteria in a total of 30 of 34 encounters, and these data were confirmed by FISH. Twenty-two of 30 Ibis-positive samples were culture-negative. Four samples were negative by all methods of analysis. No samples were positive by culture, but negative by molecular techniques. Our preliminary data indicate that molecular diagnostics are more sensitive for identifying bacteria than cultures in cases of bony nonunion. This is likely because of the inability of cultures to detect biofilms and bacteria previously exposed to antibiotic therapy. Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

  12. Intraoperative irradiation for locally recurrent colorectal cancer in previously irradiated patients

    Energy Technology Data Exchange (ETDEWEB)

    Haddock, M G; Gunderson, L L; Nelson, H; Cha, S; Devine, R M; Dozois, R R; Wolff, B G

    1995-07-01

    Purpose/Objective: Little information exists in the literature on salvage treatment for patients with pelvic recurrences of colorectal cancer who have previously received high dose radiation therapy (RT). A retrospective review of such patients treated aggressively with surgical resection and intraoperative electrons (IOERT) was undertaken. Material and Methods: From 1981 through 1994, 52 previously irradiated patients with recurrent locally advanced colorectal cancer without evidence of distant metastatic disease were treated with surgical resection and intraoperative electrons (IOERT) {+-} additional external beam RT. Every attempt was made to achieve a gross total resection prior to IOERT if it could be safely accomplished. IOERT doses ranged from 1000-3000 cGy with a median of 2000 cGy. 37 patients received additional external beam radiotherapy either pre- or post-operatively with doses ranging from 500-5040 cGy (median 2520 cGy). 20 patients received 5FU {+-} leukovorin during external beam RT. Three patients received 5FU+leukovorin after completion of RT. Results: 31 males and 21 females with a median age of 55 years (range 31-73 years) were treated. 71% of patients have been followed until death or for > 2 years. The median, 2-year and 5-year actuarial overall survival is 23 months, 48% and 13%, respectively. Actuarial central disease control (IOERT field) at 2 and 4 years is 72 and 57%; pelvic control at 2 and 4 years is 60 and 34%. Pelvic control rates are better in patients who received {>=} 3000 cGy external beam RT in addition to IOERT as compared to patients who received no external beam RT or < 3000 cGy, with 2 year pelvic control rates of 81% vs. 54%. 25 patients have developed distant metastases. The actuarial rate of appearance of distant metastatic disease at 2 and 4 years is 60 and 80%. Late complications attributable to IOERT include neuropathies in 13 patients (5 mild, 5 moderate, 3 severe) and narrowing or obstruction of the ureter in four

  13. Intraoperative irradiation for locally recurrent colorectal cancer in previously irradiated patients

    International Nuclear Information System (INIS)

    Haddock, M.G.; Gunderson, L.L.; Nelson, H.; Cha, S.; Devine, R.M.; Dozois, R.R.; Wolff, B.G.

    1995-01-01

    Purpose/Objective: Little information exists in the literature on salvage treatment for patients with pelvic recurrences of colorectal cancer who have previously received high dose radiation therapy (RT). A retrospective review of such patients treated aggressively with surgical resection and intraoperative electrons (IOERT) was undertaken. Material and Methods: From 1981 through 1994, 52 previously irradiated patients with recurrent locally advanced colorectal cancer without evidence of distant metastatic disease were treated with surgical resection and intraoperative electrons (IOERT) ± additional external beam RT. Every attempt was made to achieve a gross total resection prior to IOERT if it could be safely accomplished. IOERT doses ranged from 1000-3000 cGy with a median of 2000 cGy. 37 patients received additional external beam radiotherapy either pre- or post-operatively with doses ranging from 500-5040 cGy (median 2520 cGy). 20 patients received 5FU ± leukovorin during external beam RT. Three patients received 5FU+leukovorin after completion of RT. Results: 31 males and 21 females with a median age of 55 years (range 31-73 years) were treated. 71% of patients have been followed until death or for > 2 years. The median, 2-year and 5-year actuarial overall survival is 23 months, 48% and 13%, respectively. Actuarial central disease control (IOERT field) at 2 and 4 years is 72 and 57%; pelvic control at 2 and 4 years is 60 and 34%. Pelvic control rates are better in patients who received ≥ 3000 cGy external beam RT in addition to IOERT as compared to patients who received no external beam RT or < 3000 cGy, with 2 year pelvic control rates of 81% vs. 54%. 25 patients have developed distant metastases. The actuarial rate of appearance of distant metastatic disease at 2 and 4 years is 60 and 80%. Late complications attributable to IOERT include neuropathies in 13 patients (5 mild, 5 moderate, 3 severe) and narrowing or obstruction of the ureter in four patients

  14. Clinical experience with intraoperative radiotherapy for locally advanced colorectal cancer

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Takahashi, Masaharu; Abe, Mitsuyuki

    1988-01-01

    Intraoperative radiotherapy (IORT) was performed on 20 patients with colorectal cancer. IORT with a single dose of 20 to 40 Gy was delivered to the residual tumor, tumor bed, and/or lymphnode regions. Although most of the patients had advanced lesions, local control was achieved in 67 % of the patients when IORT was combined with tumor resection, and 4 patients survived more than 5 years. There were no serious complications, except for contracture or atrophy of the psoas muscle seen in 2 patients. IORT combined with external beam radiotherapy should be a useful adjuvant therapy to surgery for locally advanced colorectal cancer. (author)

  15. Development of a daily dosimetric control for radiation therapy using an electronic portal imaging device (EPID)

    International Nuclear Information System (INIS)

    Saboori, Mohammadsaeed

    2015-01-01

    Electronic Portal Imaging Devices (EPIDs) can be used to perform dose measurements during radiation therapy treatments if dedicated calibration and correction procedures are applied. The purpose of this study was to provide a new calibration and correction model for an amorphous silicon (a-Si) EPID for use in transit dose verification of step-and-shoot intensity modulated radiation therapy (IMRT). A model was created in a commercial treatment planning system to calculate the nominal two-dimensional (2D) dose map of each radiation field at the EPID level. The EPID system was calibrated and correction factors were determined using a reference set-up, which consisted a patient phantom and an EPID phantom. The advantage of this method is that for the calibration, the actual beam spectrum is used to mimic a patient measurement. As proof-of-principle, the method was tested for the verification of two 7-field IMRT treatment plans with tumor sites in the head-and-neck and pelvic region. Predicted and measured EPID responses were successfully compared to the nominal data from treatment planning using dose difference maps and gamma analyses. Based on our result it can be concluded that this new method of 2D EPID dosimetry is a potential tool for simple patient treatment fraction dose verification.

  16. Results of a 5-Week Schedule of Modern Total Skin Electron Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Stephen Lloyd, E-mail: stephen.morris@gstt.nhs.uk [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom); McGovern, Mark; Bayne, Sally; Wain, Mary; Child, Fiona; Whittaker, Sean [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom)

    2013-08-01

    Purpose: To report the outcomes of a 5-week schedule of total skin electron beam radiation therapy (TSEB) for mycosis fungoides (MF). Methods: Over 5 years, 41 patients with confirmed MF were treated with a modern TSEB technique delivering 30 Gy in 20 fractions over 5 weeks to the whole skin surface. Data were collected prospectively and entered into the skin tumor unit research database. Skin modified skin weighted assessment tool score data were collected to determine response, duration of response, survival, and toxicity. The outcomes were analyzed according to the patient's stage before TSEB, prognostic factors, and adjuvant treatments. Results: Seventeen patients were stage 1B, 19 were stage IIB, 3 were stage III, and 2 were stage IV. The overall response rate was 95%, with a complete response rate of 51%. Seventy-six percent of patients had relapsed at median follow-up of 18 months. The median time to relapse was 12 months, to systemic therapy was 15 months, and to modified skin weighted assessment tool progression above baseline was 44 months. The complete response rate was 59% in stage IB and 47% in stage IIB patients. The median time to skin relapse was longer in stage IB compared with stage IIB, 18 months versus 9 months. The median time to systemic therapy was longer in stage IB compared with stage IIB, >56 months versus 8 months. The median overall survival was 35 months: >56 months for stage IB, 25 months for stage IIB, 46 months for stage III, and 23.5 months for stage IV. Fifteen patients received adjuvant psoralen + ultraviolet A treatment with no difference seen in the time to relapse. Conclusions: This 5-week schedule of TSEB for MF has a high response rate with comparable duration of response to other regimens. Future studies are needed to find adjuvant and combination treatments to improve the duration of response.

  17. Results of intraoperative radiotherapy for pancreatic cancers

    International Nuclear Information System (INIS)

    Okazaki, Atsushi; Shinozaki, Jun; Noda, Masanobu

    1991-01-01

    Reported are the results and observations of the authors who, from July 1986 through December 1989, have used electron beam intraoperative radiotherapy (IORT) on 20 patients with locally advanced pancreatic cancers, said number including 3 patients given a resection. In 14 of the 17 unresected patients, a chief symptom was pain, and 8 patients were given a celiac plexus block at the same time. The results and observations are given below. Life-threatening complications occurred in two patients, i.e., an insufficient pancreatojejunostomy, and a perforative peritonitis. In 12 of 13 evaluable patients, pain control was achieved for a mean period of 5 months, indicating that an IORT with celiac plexus block may be useful for palliation. In the resected patients, the mean survival time was 6 months, whereas in the unresected patients, the mean survival time was 7 months. The common cause of death in the unresected patients was a metastatic dissemination. Finally, in 3 of the 5 unresected patients, marked effects such as massive fibrosis were seen in the pancreatic tumor on autopsy. (author)

  18. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Intraoperative radiotherapy for adenocarcinoma of the pancreas

    International Nuclear Information System (INIS)

    Yasue, Mitsunori; Yasui, Kenzo; Morimoto, Takeshi; Miyaishi, Seiichi; Morita, Kozo

    1986-01-01

    Thirty-six patients were given intraoperative radiotherapy for adenocarcinoma of the pancreas between April 1980 and March 1986. Twenty-six of those with well-advanced cancer underwent palliative intraoperative radiotherapy of their main primary lesions (1,500 to 3,000 rads). Fourteen of the 19 patients in this group who had intractable back pain before surgery achieved relief within one week after treatment. Of the remaining 10 patients who underwent pancreatectomy and received adjuvant intraoperative radiotherapy (2,000 to 3,000 rads), two remain clinically free of disease five years and six months and four years and six months after palliative distal pancreatectomy. (author)

  20. Methods for Determining Metal Uptake in Cellular DNA for Auger Electron Therapy

    International Nuclear Information System (INIS)

    Seror, V.; Novick, S.; Weiner, E.; Laster, B.; Hambright, P.

    2004-01-01

    Stable indium-labeled tetra(4-N-methylpyridyl)porphyrin [InTMPyP(4)] was evaluated as a carrier of a high Z atom, indium (In), into tumor cell DNA for its subsequent activation by radiation in a proposed radiotherapeutic technique, Auger Electron Therapy (AET). Porphyrins with metals can bind to DNA and are useful vehicles for transporting the indium to the DNA of the tumor. AET combines the use of a metalloporphyrin with a stable high Z atom, such as indium, and photons emitted from radioactive brachytherapy seeds, such as iodine-125, to increase the radiation dose in the DNA of the tumor by generating a photoelectric effect in the K absorption edge of the indium (In) atom. This results in the emission of cascading Auger electrons that act as high LET radiation and thus impart significant non-reparable damage to the tumor compared to the radiation alone. The K absorption edge of In is 27.9 keV and the average photon energy of the iodine-125 seeds is ∼ 28 keV

  1. Psychological causes of non-compliance with electronically monitored occlusion therapy for amblyopia.

    Science.gov (United States)

    Loudon, S E; Passchier, J; Chaker, L; de Vos, S; Fronius, M; Harrad, R A; Looman, C W N; Simonsz, B; Simonsz, H J

    2009-11-01

    To analyse psychological causes for low compliance with occlusion therapy for amblyopia. In a randomised trial, the effect of an educational programme on electronically measured compliance had been assessed. 149 families who participated in this trial completed a questionnaire based on the Protection Motivation Theory after 8 months of treatment. Families with compliance less than 20% of prescribed occlusion hours were interviewed to better understand their cause for non-compliance. Poor compliance was most strongly associated with a high degree of distress (p<0.001), followed by low perception of vulnerability (p = 0.014), increased stigma (p = 0.017) and logistical problems with treatment (p = 0.044). Of 44 families with electronically measured compliance less than 20%, 28 could be interviewed. The interviews confirmed that lack of knowledge, distress and logistical problems resulted in non-compliance. Poor parental knowledge, distress and difficulties implementing treatment seemed to be associated with non-compliance. For the same domains, the scores were more favourable for families who had received the educational programme than for those who had not.

  2. Automated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.

    Science.gov (United States)

    Zhang, Ling; Baldwin, Ian; Zhu, Guijun; Tanaka, Aiko; Bellomo, Rinaldo

    2015-03-01

    Automated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function. Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis. We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout. Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.

  3. Intraoperative Radiotherapy for Breast Cancer

    Directory of Open Access Journals (Sweden)

    Eleanor E. R. Harris

    2017-12-01

    Full Text Available Intraoperative radiotherapy (IORT for early stage breast cancer is a technique for partial breast irradiation. There are several technologies in clinical use to perform breast IORT. Regardless of technique, IORT generally refers to the delivery of a single dose of radiation to the periphery of the tumor bed in the immediate intraoperative time frame, although some protocols have performed IORT as a second procedure. There are two large prospective randomized trials establishing the safety and efficacy of breast IORT in early stage breast cancer patients with sufficient follow-up time on thousands of women. The advantages of IORT for partial breast irradiation include: direct visualization of the target tissue ensuring treatment of the high-risk tissue and eliminating the risk of marginal miss; the use of a single dose coordinated with the necessary surgical excision thereby reducing omission of radiation and the selection of mastectomy for women without access to a radiotherapy facility or unable to undergo several weeks of daily radiation; favorable toxicity profiles; patient convenience and cost savings; radiobiological and tumor microenvironment conditions which lead to enhanced tumor control. The main disadvantage of IORT is the lack of final pathologic information on the tumor size, histology, margins, and nodal status. When unexpected findings on final pathology such as positive margins or positive sentinel nodes predict a higher risk of local or regional recurrence, additional whole breast radiation may be indicated, thereby reducing some of the convenience and low-toxicity advantages of sole IORT. However, IORT as a tumor bed boost has also been studied and appears to be safe with acceptable toxicity. IORT has potential efficacy advantages related to overall survival related to reduced cardiopulmonary radiation doses. It may also be very useful in specific situations, such as prior to oncoplastic reconstruction to improve accuracy of

  4. The electronic view box: a software tool for radiation therapy treatment verification

    International Nuclear Information System (INIS)

    Bosch, Walter R.; Low, Daniel A.; Gerber, Russell L.; Michalski, Jeff M.; Graham, Mary V.; Perez, Carlos A.; Harms, William B.; Purdy, James A.

    1995-01-01

    Purpose: We have developed a software tool for interactively verifying treatment plan implementation. The Electronic View Box (EVB) tool copies the paradigm of current practice but does so electronically. A portal image (online portal image or digitized port film) is displayed side by side with a prescription image (digitized simulator film or digitally reconstructed radiograph). The user can measure distances between features in prescription and portal images and 'write' on the display, either to approve the image or to indicate required corrective actions. The EVB tool also provides several features not available in conventional verification practice using a light box. Methods and Materials: The EVB tool has been written in ANSI C using the X window system. The tool makes use of the Virtual Machine Platform and Foundation Library specifications of the NCI-sponsored Radiation Therapy Planning Tools Collaborative Working Group for portability into an arbitrary treatment planning system that conforms to these specifications. The present EVB tool is based on an earlier Verification Image Review tool, but with a substantial redesign of the user interface. A graphical user interface prototyping system was used in iteratively refining the tool layout to allow rapid modifications of the interface in response to user comments. Results: Features of the EVB tool include 1) hierarchical selection of digital portal images based on physician name, patient name, and field identifier; 2) side-by-side presentation of prescription and portal images at equal magnification and orientation, and with independent grayscale controls; 3) 'trace' facility for outlining anatomical structures; 4) 'ruler' facility for measuring distances; 5) zoomed display of corresponding regions in both images; 6) image contrast enhancement; and 7) communication of portal image evaluation results (approval, block modification, repeat image acquisition, etc.). Conclusion: The EVB tool facilitates the rapid

  5. MO-E-BRD-03: Intra-Operative Breast Brachytherapy: Is One Stop Shopping Best?

    International Nuclear Information System (INIS)

    Libby, B.

    2015-01-01

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current

  6. Intraoperative neurophysiological monitoring for the anaesthetist

    African Journals Online (AJOL)

    2012-11-15

    Nov 15, 2012 ... ... nerve tracts, and by understanding how anaesthetic agents affect the various ... of the physiologically sensitive nervous system and different ... Keywords: evoked potentials, intraoperative monitoring, brain mapping. Abstract.

  7. Threshold dose for peripheral neuropathy following intraoperative radiotherapy (IORT) in a large animal model

    International Nuclear Information System (INIS)

    Kinsella, T.J.; DeLuca, A.M.; Barnes, M.; Anderson, W.; Terrill, R.; Sindelar, W.F.

    1991-01-01

    Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers and perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy

  8. Design, construction and performance evaluation of the target tissue thickness measurement system in intraoperative radiotherapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yazdani, Mohammad Reza, E-mail: myazdani@aut.ac.ir [Faculty of Energy Engineering and Physics, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Setayeshi, Saeed, E-mail: setayesh@aut.ac.ir [Faculty of Energy Engineering and Physics, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Arabalibeik, Hossein, E-mail: arabalibeik@tums.ac.ir [Research Center for Biomedical Technology and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Akbari, Mohammad Esmaeil [Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2017-05-21

    Intraoperative electron radiation therapy (IOERT), which uses electron beams for irradiating the target directly during the surgery, has the advantage of delivering a homogeneous dose to a controlled layer of tissue. Since the dose falls off quickly below the target thickness, the underlying normal tissues are spared. In selecting the appropriate electron energy, the accuracy of the target tissue thickness measurement is critical. In contrast to other procedures applied in IOERT, the routine measurement method is considered to be completely traditional and approximate. In this work, a novel mechanism is proposed for measuring the target tissue thickness with an acceptable level of accuracy. An electronic system has been designed and manufactured with the capability of measuring the tissue thickness based on the recorded electron density under the target. The results indicated the possibility of thickness measurement with a maximum error of 2 mm for 91.35% of data. Aside from system limitation in estimating the thickness of 5 mm phantom, for 88.94% of data, maximum error is 1 mm.

  9. Integration of a mobile-integrated therapy with electronic health records: lessons learned.

    Science.gov (United States)

    Peeples, Malinda M; Iyer, Anand K; Cohen, Joshua L

    2013-05-01

    Responses to the chronic disease epidemic have predominantly been standardized in their approach to date. Barriers to better health outcomes remain, and effective management requires patient-specific data and disease state knowledge be presented in methods that foster clinical decision-making and patient self-management. Mobile technology provides a new platform for data collection and patient-provider communication. The mobile device represents a personalized platform that is available to the patient on a 24/7 basis. Mobile-integrated therapy (MIT) is the convergence of mobile technology, clinical and behavioral science, and scientifically validated clinical outcomes. In this article, we highlight the lessons learned from functional integration of a Food and Drug Administration-cleared type 2 diabetes MIT into the electronic health record (EHR) of a multiphysician practice within a large, urban, academic medical center. In-depth interviews were conducted with integration stakeholder groups: mobile and EHR software and information technology teams, clinical end users, project managers, and business analysts. Interviews were summarized and categorized into lessons learned using the Architecture for Integrated Mobility® framework. Findings from the diverse stakeholder group of a MIT-EHR integration project indicate that user workflow, software system persistence, environment configuration, device connectivity and security, organizational processes, and data exchange heuristics are key issues that must be addressed. Mobile-integrated therapy that integrates patient self-management data with medical record data provides the opportunity to understand the potential benefits of bidirectional data sharing and reporting that are most valuable in advancing better health and better care in a cost-effective way that is scalable for all chronic diseases. © 2013 Diabetes Technology Society.

  10. Accelerator based production of auger-electron-emitting isotopes for radionuclide therapy

    International Nuclear Information System (INIS)

    Thisgaard, H.

    2008-08-01

    In this research project the focus has been on the identification and production of new, unconventional Auger-electron-emitting isotopes for targeted radionuclide therapy of cancer. Based on 1st principles dosimetry calculations on the subcellular level, the Auger-emitter 119Sb has been identified as a potent candidate for therapy. The corresponding imaging analogue 117Sb has been shown from planar scintigraphy and single-photon emission computed tomography (SPECT) to be suitable for SPECT-based dosimetry of a future Sb-labeled radiopharmaceutical. The production method of these radioisotopes has been developed using a low-energy cyclotron via the nuclear reactions 119Sn(p,n)119Sb and 117Sn(p,n)117Sb including measurements of the excitation function for the former reaction. Moreover, a new high-yield radiochemical separation method has been developed to allow the subsequent separation of the produced 119Sb from the enriched 119Sn target material with high radionuclidic- and chemical purity. A method that also allows efficient recovery of the 119Sn for recycling. To demonstrate the ability of producing therapeutic quantities of 119Sb and other radioisotopes for therapy with a low-energy cyclotron, two new 'High Power' cyclotron targets were developed in this study. The target development was primarily based on theoretical thermal modeling calculations using finite-element-analysis software. With these targets, I have shown that it will be possible to produce several tens of GBq of therapeutics isotopes (e.g. 119Sb or 64Cu) using the PETtrace cyclotron commonly found at the larger PET-centers in the hospitals. Finally, research in a new method to measure the radiotoxicity of Auger-emitters invitro using cellular microinjection has been carried out. The purpose of this method is to be able to experimentally evaluate and compare the potency of the new and unconventional Auger-emitters (e.g. 119Sb). However, due to experimental complications, the development of this

  11. Accelerator based production of auger-electron-emitting isotopes for radionuclide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Thisgaard, H.

    2008-08-15

    In this research project the focus has been on the identification and production of new, unconventional Auger-electron-emitting isotopes for targeted radionuclide therapy of cancer. Based on 1st principles dosimetry calculations on the subcellular level, the Auger-emitter 119Sb has been identified as a potent candidate for therapy. The corresponding imaging analogue 117Sb has been shown from planar scintigraphy and single-photon emission computed tomography (SPECT) to be suitable for SPECT-based dosimetry of a future Sb-labeled radiopharmaceutical. The production method of these radioisotopes has been developed using a low-energy cyclotron via the nuclear reactions 119Sn(p,n)119Sb and 117Sn(p,n)117Sb including measurements of the excitation function for the former reaction. Moreover, a new high-yield radiochemical separation method has been developed to allow the subsequent separation of the produced 119Sb from the enriched 119Sn target material with high radionuclidic- and chemical purity. A method that also allows efficient recovery of the 119Sn for recycling. To demonstrate the ability of producing therapeutic quantities of 119Sb and other radioisotopes for therapy with a low-energy cyclotron, two new 'High Power' cyclotron targets were developed in this study. The target development was primarily based on theoretical thermal modeling calculations using finite-element-analysis software. With these targets, I have shown that it will be possible to produce several tens of GBq of therapeutics isotopes (e.g. 119Sb or 64Cu) using the PETtrace cyclotron commonly found at the larger PET-centers in the hospitals. Finally, research in a new method to measure the radiotoxicity of Auger-emitters invitro using cellular microinjection has been carried out. The purpose of this method is to be able to experimentally evaluate and compare the potency of the new and unconventional Auger-emitters (e.g. 119Sb). However, due to experimental complications, the development

  12. Histopathological effects of intraoperative radiotherapy on pancreas and adjacent tissues: a postmortem analysis

    International Nuclear Information System (INIS)

    Hoekstra, H.J.; Restrepo, C.; Kinsella, T.J.; Sindelar, W.F.

    1988-01-01

    Intraoperative radiotherapy (IORT) has been utilized in the treatment of resectable and unresectable pancreatic carcinoma at the National Cancer Institute. Detailed autopsy analyses of the radiation effects on the pancreas and adjacent tissues were performed on 13 patients dying at various times following therapy. IORT can induce a progressive retroperitoneal fibrosis and fibrosis of the porta hepatis in patients with resectable pancreatic carcinoma. In unresectable pancreatic carcinoma, the major expression of intraoperative irradiation with external beam irradiation is a progressive fibrosis of the pancreas with vascular sclerosis, nerve degeneration, atrophy of acinar cells, and atypical changes in the ducts of the pancreas, as well as degenerative changes of the pancreatic tumor

  13. Determination of absorbed dose calibration factors for therapy level electron beam ionization chambers.

    Science.gov (United States)

    McEwen, M R; Williams, A J; DuSautoy, A R

    2001-03-01

    Over several years the National Physical Laboratory (NPL) has been developing an absorbed dose calibration service for electron beam radiotherapy. To test this service, a number of trial calibrations of therapy level electron beam ionization chambers have been carried out during the last 3 years. These trials involved 17 UK radiotherapy centres supplying a total of 46 chambers of the NACP, Markus, Roos and Farmer types. Calibration factors were derived from the primary standard calorimeter at seven energies in the range 4 to 19 MeV with an estimated uncertainty of +/-1.5% at the 95% confidence level. Investigations were also carried out into chamber perturbation, polarity effects, ion recombination and repeatability of the calibration process. The instruments were returned to the radiotherapy centres for measurements to be carried out comparing the NPL direct calibration with the 1996 IPEMB air kerma based Code of Practice. It was found that, in general, all chambers of a particular type showed the same energy response. However, it was found that polarity and recombination corrections were quite variable for Markus chambers-differences in the polarity correction of up to 1% were seen. Perturbation corrections were obtained and were found to agree well with the standard data used in the IPEMB Code. The results of the comparison between the NPL calibration and IPEMB Code show agreement between the two methods at the +/-1% level for the NACP and Farmer chambers, but there is a significant difference for the Markus chambers of around 2%. This difference between chamber types is most likely to be due to the design of the Markus chamber.

  14. Evaluation of image quality for various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Son, Soon Yong; Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Kim, Jung Min [Dept. of College of Health Science, Radiologic Science, Korea University, Seoul (Korea, Republic of); and others

    2015-12-15

    In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta) and Clinac®iX (Varian) were used. As for MTF results, TrueBeamTM(Varian) flattening filter free(FFF) showed the highest values of 0.46 mm-1and1.40mm-1for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and 1 mm-1DQE of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID)

  15. Influence of volume on intraoperatively irradiated canine ureters

    International Nuclear Information System (INIS)

    Gillette, S.M.; Powers, B.E.; Thames, H.D.; Vujaskovic, Z.; LaRue, S.M.; Park, R.D.; Gillette, E.L.

    1995-01-01

    Purpose/Objective: Intraoperative radiation therapy (IORT) is used to deliver high single doses of radiation to the tumor bed following surgical removal of various abdominal malignancies. The advantage of IORT is the ability to remove sensitive normal tissues from the treatment field and limit the volume of normal tissue irradiated. The purpose of this study was to determine dose-volume relationships for retroperitoneal tissues. Materials and methods: 134 adult beagle dogs were irradiated to the surgically exposed paraaortic area. Normal tissues included in the treatment field were aorta, peripheral nerve, ureter, bone and the muscle. Groups of 4 - 8 dogs were irradiated to doses ranging from 18 - 54 Gy for a 2x5 cm field, from 12 - 46 Gy for a 4x5 cm field, and 12 - 42 Gy to an 8x5 cm field. The radiations were done using 6 MeV electrons from a linear accelerator. Dogs were observed for three years after radiation at which time they were euthanatized, perfused and tissues taken for histologic and histomorphometric evaluation. Transverse sections of the ureter were taken from the proximal, middle and distal segments. Histologically, proximal portions of the ureters with greater than 5 times normal diameter were considered to have severe hydroureter. Ureteral strictures and hydroneophrosis were evaluated by excretory urograms. Excretory urograms were done prior to treatment and annually after treatment or prior to necropsy for each dog in the experiments. A grading system was devised for predicting ureteral stenosis based on ureteral and renal pelvic dilatation. Results: A strong dose and volume relationship was identified for ureteral injury using the mixture model analysis which takes into account latency as well as dose. Subsequent to earlier edema, fibrin and vessel damage, progressive fibrosis developed and likely caused uteral stricture resulting in hydroureter. Severe hydroureter was observed as early as three months. The ED 50 for hydroureter determined

  16. [Selective intraoperative cholangiography in laparoscopic cholecystectomy].

    Science.gov (United States)

    Pickuth, D; Leutloff, U

    1995-01-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments; however, it is controversial. We have developed a new diagnostic strategy for the detection of bile duct stones. The concept is based on an ultrasound examination and on screening for the presence of six risk indicators of choledocholithiasis. A total of 120 patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of these six risk indicators: history of jaundice, history of pancreatitis, hyperbilirubinemia, hyperamylasemia, dilated bile duct, and unclear ultrasound findings. The sensitivity of ultrasound and intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. Twenty percent of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (P concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that routine use of intraoperative cholangiography is not necessary.

  17. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  18. Discussion of feasibility to carry out intensity modulated radiation therapy in conventional medical electron linear accelerator treatment rooms

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Zhang Liang; Yu Shui

    2010-01-01

    Objective: To investigate the feasibility about the shielding effect of conventional medical electron linear accelerator treatment in the existing rooms to carry out intensity modulated radiation therapy (IMRT). Methods: The estimation model given in NCRP REPORT No. 151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities i s adopted by linking instances, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The radiation level, as well as the additional annual effect dose of occupational and public at the ambience of accelerator treatment room, in crease to a certain extent, when conventional medical electron linear accelerator treatment room; are used to carry out IMRT. Conclusion: It is necessary to make environmental impact assessment for conventional medical electron linear accelerator treatment rooms, which will be used to execute IMRT. (authors)

  19. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    Science.gov (United States)

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as

  20. Evaluation of alanine as a reference dosimeter for therapy level dose comparisons in megavoltage electron beams

    International Nuclear Information System (INIS)

    McEwen, Malcolm; Sharpe, Peter; Voros, Sandor

    2015-01-01

    When comparing absorbed dose standards from different laboratories (e.g. National Measurement Institutes, NMIs, for Key or Supplementary comparisons) it is rarely possible to carry out a direct comparison of primary standard instruments, and therefore some form of transfer detector is required. Historically, air-filled, unsealed ionization chambers have been used because of the long history of using these instruments, very good stability over many years, and ease of transport. However, the use of ion chambers for therapy-level comparisons is not without its problems. Findings from recent investigations suggest that ion chambers are prone to non-random variations, they are not completely robust to standard courier practices, and failure at any step in a comparison can render all measurements potentially useless. An alternative approach is to identify a transfer system that is insensitive to some of these concerns - effectively a dosimeter that is inexpensive, simple to use, robust, but with sufficient precision and of a size relevant to the disseminated quantity in question. The alanine dosimetry system has been successfully used in a number of situations as an audit dosimeter and therefore the purpose of this investigation was to determine whether alanine could also be used as the transfer detector for dosimetric comparisons, which require a lower value for the measurement uncertainty. A measurement protocol was developed for comparing primary standards of absorbed dose to water in high-energy electron beams using alanine pellets irradiated in a water-equivalent plastic phantom. A trial comparison has been carried out between three NMIs and has indicated that alanine is a suitable alternative to ion chambers, with the system used achieving a precision of 0.1%. Although the focus of the evaluation was on the performance of the dosimeter, the comparison results are encouraging, showing agreement at the level of the combined uncertainties (∼0.6%). Based on this

  1. Intraoperative radiotherapy for cancer of the pancreas

    International Nuclear Information System (INIS)

    Manabe, Tadao; Nagai, Toshihiro; Tobe, Takayoshi; Shibamoto, Yuta; Takahashi, Masaharu; Abe, Mitsuyuki

    1985-01-01

    Seven patients treated by intraoperative radiotherapy for cancer of the pancreas were evaluated. Three patients undergoing pancreaticoduodenectomy for cancer of the head of the pancreas received a dose of 2,500--3,000 rad (6--10 MeV Betatron) intraoperatively with or without external beam irradiation at a dose of 2,520 rad (10 MeV lineac X-ray). One patient developed radiation pancreatitis and died 0.8 month after surgery. Autopsy revealed the degeneration of cancer cells in the involved superior mesenteric artery. One died of hepatic metastasis 8.5 months after surgery, however, recurrence was not found in the irradiation field. The other patient who had external beam irradiation combined with intraoperative radiotherapy is alive 7.5 months after surgery. Four patients with unresectable cancer of the body of the pancreas received a dose of 2,500--3,000 rad (13--18 MeV Betatron) intraoperatively with or without external beam irradiation at a dose of 1,500--5,520 rad (10 MeV lineac X-ray). One patient died of peritonitis carcinomatosa 3.0 months after surgery. One patient died of DIC 0.6 month after surgery. Two patients are alive 1.0 and 6.5 months after surgery. In these patients with intraoperative radiotherapy for unresectable cancer of the pancreas, remarkable effects on relief of pain and shrinkage of tumor were obtained. Further pursuit of intraoperative and external beam radiotherapies in combination with pancreatectomy should be indicated in an attempt to prolong survival of patient with cancer of the pancreas. (author)

  2. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  3. Correlates of use of electronic cigarettes versus nicotine replacement therapy for help with smoking cessation.

    Science.gov (United States)

    Pokhrel, Pallav; Little, Melissa A; Fagan, Pebbles; Kawamoto, Crissy T; Herzog, Thaddeus A

    2014-12-01

    Electronic- or e-cigarettes are nicotine-delivery devices commonly used by smokers to quit or reduce smoking. At present, not much is known about the characteristics of smokers who specifically try e-cigarettes to quit smoking compared to the nicotine replacement therapy (NRT) products approved by the U.S. Food and Drug Administration (FDA). Determining the characteristics of smokers who are likely to choose e-cigarettes as cessation aids would help develop strategies to impart valid information about e-cigarettes to such smokers as facts regarding the safety and utility of e-cigarettes emerge. This study is based on 834 daily smokers [mean age=45.8 (standard deviation=13)] from Hawaii. Demographic, smoking- and cessation-related variables were examined as correlates of ever use of e-cigarette only or any FDA-approved NRT product only or both as cessation aids. Results indicated that younger smokers, non-White smokers, and smokers reporting higher income, lower nicotine dependence, shorter smoking history, and higher lifetime quit attempts were more likely to have tried e-cigarettes but not NRT products for help with smoking cessation. Smokers who are attracted to use e-cigarettes but not FDA-approved NRT products may differ from smokers who are likely to have used NRT products but not e-cigarettes in terms of demographic (e.g., age, ethnicity) and smoking- or cessation-related characteristics (e.g., nicotine dependence, quit attempts). Given the lack of knowledge regarding the health effects of e-cigarettes and their efficacy as cessation aids, future research needs to continue characterizing smokers who are likely to use e-cigarettes for smoking cessation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Revisiting Low-Dose Total Skin Electron Beam Therapy in Mycosis Fungoides

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cameron, E-mail: cameronh@stanford.edu [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Young, James; Navi, Daniel [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Riaz, Nadeem [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States); Lingala, Bharathi; Kim, Youn [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Hoppe, Richard [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States)

    2011-11-15

    Purpose: Total skin electron beam therapy (TSEBT) is a highly effective treatment for mycosis fungoides (MF). The standard course consists of 30 to 36 Gy delivered over an 8- to 10-week period. This regimen is time intensive and associated with significant treatment-related toxicities including erythema, desquamation, anhydrosis, alopecia, and xerosis. The aim of this study was to identify a lower dose alternative while retaining a favorable efficacy profile. Methods and Materials: One hundred two MF patients were identified who had been treated with an initial course of low-dose TSEBT (5-<30 Gy) between 1958 and 1995. Patients had a T stage classification of T2 (generalized patch/plaque, n = 51), T3 (tumor, n = 29), and T4 (erythrodermic, n = 22). Those with extracutaneous disease were excluded. Results: Overall response (OR) rates (>50% improvement) were 90% among patients with T2 to T4 disease receiving 5 to <10 Gy (n = 19). In comparison, OR rates between the 10 to <20 Gy and 20 to <30 Gy subgroups were 98% and 97%, respectively. There was no significant difference in median progression free survival (PFS) in T2 and T3 patients when stratified by dose group, and PFS in each was comparable to that of the standard dose. Conclusions: OR rates associated with low-dose TSEBT in the ranges of 10 to <20 Gy and 20 to <30 Gy are comparable to that of the standard dose ({>=} 30 Gy). Efficacy measures including OS, PFS, and RFS are also favorable. Given that the efficacy profile is similar between 10 and <20 Gy and 20 and <30 Gy, the utility of TSEBT within the lower dose range of 10 to <20 Gy merits further investigation, especially in the context of combined modality treatment.

  5. Intraoperative high-dose-rate brachytherapy for the treatment of pediatric tumors: the Ohio State University experience

    International Nuclear Information System (INIS)

    Nag, Subir; Tippin, Douglas; Ruymann, Frederick B.

    2001-01-01

    Purpose: To determine whether intraoperative high-dose-rate brachytherapy (IO-HDRBT) can be used to decrease the dose of external beam radiotherapy (EBRT) in the treatment of children with soft-tissue sarcomas and, thereby, reduce morbidity without compromising local control. Methods and Materials: From March 1992 through April 1999, 13 pediatric patients were treated with IO-HDRBT, low-dose EBRT, chemotherapy, and radical surgery at 21 sites that were not amenable to intraoperative electron beam therapy. The IO-HDRBT dose at 5 mm depth was 10 to 12.5 Gy for close margins/microscopic disease at 14 sites and 12.5 to 15 Gy for gross disease at 7 sites. The treatment volumes ranged from 4 to 96 cm 3 (mean 27). The EBRT dose was limited to 27-30 Gy in most cases to minimize growth retardation and preserve normal organ function. Results: After a median follow-up of 47 months (range 12-97), 11 patients were alive and without evidence of disease (overall survival rate 85%, 4-year actuarial survival rate 77%). Of the 2 who died, 1 had Stage III pulmonary blastoma with a sacral recurrence; the other had Stage IV undifferentiated synovial sarcoma with a pulmonary recurrence. One local failure occurred in a patient with gross residual disease after incomplete resection for Stage IV pulmonary blastoma. The local control rate was 95%, and morbidity was observed in 3 patients (23%). One patient developed impaired orbital growth with mild ptosis. Another patient required orthopedic pinning of her femoral subcapital epiphysis and construction of a neobladder secondary to urethral obstruction. The third patient required reimplantation of her autotransplanted kidney secondary to chronic urinary tract infection and ureteral reflux. Conclusions: IO-HDRBT allowed for reduction in EBRT without compromising local control or disease-free survival in children with soft-tissue sarcomas. Tumor beds inaccessible to electron beam methods could be satisfactorily encompassed with IO

  6. Automatic atlas based electron density and structure contouring for MRI-based prostate radiation therapy on the cloud

    International Nuclear Information System (INIS)

    Dowling, J A; Burdett, N; Chandra, S; Rivest-Hénault, D; Ghose, S; Salvado, O; Fripp, J; Greer, P B; Sun, J; Parker, J; Pichler, P; Stanwell, P

    2014-01-01

    Our group have been developing methods for MRI-alone prostate cancer radiation therapy treatment planning. To assist with clinical validation of the workflow we are investigating a cloud platform solution for research purposes. Benefits of cloud computing can include increased scalability, performance and extensibility while reducing total cost of ownership. In this paper we demonstrate the generation of DICOM-RT directories containing an automatic average atlas based electron density image and fast pelvic organ contouring from whole pelvis MR scans.

  7. Automatic Atlas Based Electron Density and Structure Contouring for MRI-based Prostate Radiation Therapy on the Cloud

    Science.gov (United States)

    Dowling, J. A.; Burdett, N.; Greer, P. B.; Sun, J.; Parker, J.; Pichler, P.; Stanwell, P.; Chandra, S.; Rivest-Hénault, D.; Ghose, S.; Salvado, O.; Fripp, J.

    2014-03-01

    Our group have been developing methods for MRI-alone prostate cancer radiation therapy treatment planning. To assist with clinical validation of the workflow we are investigating a cloud platform solution for research purposes. Benefits of cloud computing can include increased scalability, performance and extensibility while reducing total cost of ownership. In this paper we demonstrate the generation of DICOM-RT directories containing an automatic average atlas based electron density image and fast pelvic organ contouring from whole pelvis MR scans.

  8. Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Andreozzi, Jacqueline M., E-mail: Jacqueline.M.Andreozzi.th@dartmouth.edu, E-mail: Lesley.A.Jarvis@hitchcock.org; Glaser, Adam K. [Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 (United States); Zhang, Rongxiao [Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States); Gladstone, David J.; Williams, Benjamin B.; Jarvis, Lesley A., E-mail: Jacqueline.M.Andreozzi.th@dartmouth.edu, E-mail: Lesley.A.Jarvis@hitchcock.org [Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03766 (United States); Pogue, Brian W. [Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States)

    2016-02-15

    Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial

  9. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  10. Intraoperative neuropathology of glioma recurrence: cell detection and classification

    Science.gov (United States)

    Abas, Fazly S.; Gokozan, Hamza N.; Goksel, Behiye; Otero, Jose J.; Gurcan, Metin N.

    2016-03-01

    Intraoperative neuropathology of glioma recurrence represents significant visual challenges to pathologists as they carry significant clinical implications. For example, rendering a diagnosis of recurrent glioma can help the surgeon decide to perform more aggressive resection if surgically appropriate. In addition, the success of recent clinical trials for intraoperative administration of therapies, such as inoculation with oncolytic viruses, may suggest that refinement of the intraoperative diagnosis during neurosurgery is an emerging need for pathologists. Typically, these diagnoses require rapid/STAT processing lasting only 20-30 minutes after receipt from neurosurgery. In this relatively short time frame, only dyes, such as hematoxylin and eosin (H and E), can be implemented. The visual challenge lies in the fact that these patients have undergone chemotherapy and radiation, both of which induce cytological atypia in astrocytes, and pathologists are unable to implement helpful biomarkers in their diagnoses. Therefore, there is a need to help pathologists differentiate between astrocytes that are cytologically atypical due to treatment versus infiltrating, recurrent, neoplastic astrocytes. This study focuses on classification of neoplastic versus non-neoplastic astrocytes with the long term goal of providing a better neuropathological computer-aided consultation via classification of cells into reactive gliosis versus recurrent glioma. We present a method to detect cells in H and E stained digitized slides of intraoperative cytologic preparations. The method uses a combination of the `value' component of the HSV color space and `b*' component of the CIE L*a*b* color space to create an enhanced image that suppresses the background while revealing cells on an image. A composite image is formed based on the morphological closing of the hue-luminance combined image. Geometrical and textural features extracted from Discrete Wavelet Frames and combined to classify

  11. The Use of Electronic Games in Therapy: a Review with Clinical Implications

    OpenAIRE

    Horne-Moyer, H. Lynn; Moyer, Brian H.; Messer, Drew C.; Messer, Elizabeth S.

    2014-01-01

    Therapists and patients enjoy and benefit from interventions that use electronic games (EG) in health care and mental health settings, with a variety of diagnoses and therapeutic goals. We reviewed the use of electronic games designed specifically for a therapeutic purpose, electronic games for psychotherapy (EGP), also called serious games, and commercially produced games used as an adjunct to psychotherapy, electronic games for entertainment (EGE). Recent research on the benefits of EG in r...

  12. Intraoperative neurophysiological monitoring for the anaesthetist ...

    African Journals Online (AJOL)

    Intraoperative neurophysiological monitoring (IONM) has become the gold standard for the monitoring of functional nervous tissue and mapping of eloquent brain tissue during neurosurgical procedures. The multimodal use of somatosensory-evoked potentials and motor-evoked potentials ensures adequate monitoring of ...

  13. Intraoperative and recovery room outcome | Edomwonyi | East ...

    African Journals Online (AJOL)

    Objectives: To identify and quantitate anaesthesia related complications in the intraoperative period and in the post anaesthesia recovery room. Design: A prospective study. Setting: University of Benin Teaching Hospital; a University - affiliated tertiary centre. Subjects: Patients scheduled for elective and emergency surgery ...

  14. Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset.

    Science.gov (United States)

    Carver, Robert L; Sprunger, Conrad P; Hogstrom, Kenneth R; Popple, Richard A; Antolak, John A

    2016-05-08

    The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.

  15. Indocyanine green for intraoperative localization of ureter.

    Science.gov (United States)

    Siddighi, Sam; Yune, Junchan Joshua; Hardesty, Jeffrey

    2014-10-01

    Intraurethral injection of indocyanine green (ICG; Akorn, Lake Forest, IL) and visualization under near-infrared (NIR) light allows for real-time delineation of the ureter. This technology can be helpful to prevent iatrogenic ureteral injury during pelvic surgery. Patients were scheduled to undergo robot-assisted laparoscopic sacrocolpopexy. Before the robotic surgery started, the tip of a 6-F ureteral catheter was inserted into the ureteral orifice. Twenty-five milligrams of ICG was dissolved in 10-mL of sterile water and injected through the open catheter. The same procedure was repeated on the opposite side. The ICG reversibly stained the inside lining of the ureter by binding to proteins on urothelial layer. During the course of robotic surgery, the NIR laser on the da Vinci Si surgical robot (Intuitive Surgical, Inc, Sunnyvale, CA) was used to excite ICG molecules, and infrared emission was captured by the da Vinci filtered lens system and electronically converted to green color. Thus, the ureter fluoresced green, which allowed its definitive identification throughout the entire case. In all cases of >10 patients, we were able to visualize bilateral ureters with this technology, even though there was some variation in brightness that depended on the depth of the ureter from the peritoneal surface. For example, in a morbidly obese patient, the ureters were not as bright green. There were no intraoperative or postoperative adverse effects attributable to ICG administration for up to 2 months of observation. In our experience, this novel method of intraurethral ICG injection was helpful to identify the entire course of ureter and allowed a safe approach to tissues that were adjacent to the urinary tract. The advantage of our technique is that it requires the insertion of just the tip of ureteral catheter. Despite our limited cohort of patients, our findings are consistent with previous reports of the excellent safety profile of intravenous and intrabiliary ICG

  16. A case of lumbar pain after intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Wakako; Ogino, Takashi; Murakami, Koji; Nawano, Shigeru; Moriyama, Noriyuki; Ryu, Munemasa; Kawano, Nariaki

    1996-01-01

    We report a case of abnormal magnetic resonance imaging (MRI) findings after intraoperative radiotherapy. A 53-year-old woman with cancer of the papilla of Vater was treated with pancreatoduodenectomy and 20 Gy of intraoperative radiotherapy by electron beam to the tumor bed. Three months later the patient complained of lumbar pain. A change of signal intensity on MRI was detected in the anterior half of the vertebral body within the irradiated field. The signal was of high intensity but was not enhanced by Gd-DTPA on T1-weighted images, was isointense on T2-weighted images and of low intensity with the fat-suppression method. The radiation dose to the lumbar spine and the surrounding soft tissue was calculated to be 16 Gy. Histologic changes in bone after irradiation may include depletion of bone marrow cells and fat degeneration. The MRI findings were compatible with these changes. The radiation dose that can be tolerated by soft tissue is lower than that tolerated by bone. Therefore, late radiation injury of the soft tissue might have been the cause of the patient's lumbar pain. (author)

  17. Evaluation of new iodinated acridine derivatives for targeted radionuclide therapy of melanoma using {sup 125}I, an Auger electron emitter

    Energy Technology Data Exchange (ETDEWEB)

    Gardette, M.; Papon, J.; Bonnet, M.; Labarre, P.; Miot-Noirault, E.; Madelmont, J. C.; Chezal, J. M.; Moins, N. [UMR 990, INSERM, Universite d' Auvergne, Clermont-Ferrand (France); Desbois, N. [EA 3660, Universite de Bourgogne, Dijon (France); Wu, T. D.; Guerquin-Kern, J. L. [U 759 INSERM, Institute Curie, Orsay (France)

    2013-06-01

    The full text of the publication follows. The increasing incidence of melanoma and the lack of effective therapy on the disseminated form have led to an urgent need for new specific therapies. Several iodo-benzamides or analogs are known to possess specific affinity for melanoma tissue. New hetero-aromatic derivatives have been designed with a cytotoxic moiety and termed DNA intercalating agents. These compounds could be applied in targeted radionuclide therapy using {sup 125}I, Auger electrons emitter which gives high-energetic localized irradiation. Two iodinated acridine derivatives have been reported to present an in vivo kinetic profile conducive to application in targeted radionuclide therapy. The aim of the present study was to perform a preclinical evaluation of these compounds. The DNA intercalating property was confirmed for both compounds. After radiolabeling with {sup 125}I, the two compounds induced in vitro a significant radiotoxicity on B16F0 melanoma cells. The acridine compound, ICF01040, appeared more radio toxic than the acridone compound, ICF01035. While cellular uptake was similar for both compounds, SIMS analysis and in vitro protocol showed a stronger affinity for melanin with ICF01035, which was able to induce a predominant scavenging process in the melanosome and restrict access to the nucleus. Nevertheless, an important radiotoxicity was measured for the two compounds while the nuclear accumulation was low. Indeed, even if nuclear localization remains the main target sensitive to Auger electrons, the cell membrane remains sensitive to {sup 125}I decays. So, these compounds may induce secondary toxic effects of irradiation, such as membrane lipid damage. Conducted to current experiments are evaluate such hypothesis. Taken together, these results suggest that ICF01040 is a better candidate for application in targeted radionuclide therapy using {sup 125}I. The next step will be in vivo evaluation, where high tumoral vectorization gives

  18. The Use of Backscattered Electron Imaging and Transmission Electron Microscopy to Assess Bone Architecture and Mineral Loci: Effect of Intermittent Slow-Release Sodium Fluoride Therapy

    Science.gov (United States)

    Zerwekh, Joseph E.; Bellotto, Dennis; Prostak, Kenneth S.; Hagler, Herbert K.; Pak, Charles Y. C.

    1996-04-01

    Backscattered electron imaging (BEI) and transmission electron microscopy (TEM) were used to examine the effects of treatment with intermittent slow-release sodium fluoride (SRNaF) and continuous calcium citrate on bone architecture and crystallinity. Examination was performed in nondecalcified biopsies obtained from patients following up to four years of therapy (placebo or SRNaF) and compared to pretreatment biopsies from each patient, as well as to bone from young, normal subjects. BEI images disclosed increased areas of recent bone formation following fluoride administration. There was no evidence of a mineralization defect in any biopsy and both cortical and trabecular architecture remained normal. TEM analysis demonstrated intrafibrillar platelike crystals and extrafibrillar needlelike crystals for both the pre- and post-treatment biopsies as well as for the bone from young normal subjects. There was no evidence of increased crystal size or of an increase in extrafibrillar mineral deposition. These observations suggest that intermittent SRNaF and continuous calcium therapy exerts an anabolic action on the skeleton not accompanied by a mineralization defect or an alteration of bone mineral deposition. The use of BEI and TEM holds promise for the study of the pathophysiology and treatment of metabolic bone diseases.

  19. Intraoperative high-field magnetic resonance imaging, multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas.

    Science.gov (United States)

    Li, Fang-Ye; Chen, Xiao-Lei; Xu, Bai-Nan

    2016-09-01

    To determine the beneficial effects of intraoperative high-field magnetic resonance imaging (MRI), multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas. Twelve patients with 13 supratentorial cavernomas were prospectively enrolled and operated while using a 1.5 T intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. All cavernomas were deeply located in subcortical areas or involved critical areas. Intraoperative high-field MRIs were obtained for the intraoperative "visualization" of surrounding eloquent structures, "brain shift" corrections, and navigational plan updates. All cavernomas were successfully resected with guidance from intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. In 5 cases with supratentorial cavernomas, intraoperative "brain shift" severely deterred locating of the lesions; however, intraoperative MRI facilitated precise locating of these lesions. During long-term (>3 months) follow-up, some or all presenting signs and symptoms improved or resolved in 4 cases, but were unchanged in 7 patients. Intraoperative high-field MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring are helpful in surgeries for the treatment of small deeply seated subcortical cavernomas.

  20. The electron affinity of some radiotherapeutic agents used in cancer therapy

    International Nuclear Information System (INIS)

    Wold, E.; Kaalhus, O.; Johansen, E.S.; Ekse, A.T.

    1980-01-01

    In order to evaluate whether chemotherapeutic compounds applied in cancer treatment might interact with radiation as anoxic cell sensitizers, the electron-affinic properties of DTIC (5-(3,3-dimethyl-1-triazeno)imidazole-4 carboxamide) AIC 4(5)-aminoimidazole-5(4)-carboxamide, hydroxyurea, busulfan and cyclophosphamide were studied by pulse radiolysis. Reaction rates with hydrated electrons were determined for all these compounds. With the exception of DTIC, they all reacted much more slowly with electrons than do most electron-affinic sensitizers. One-electron reduction potentials were determined for DTIC, AIC and hydroxyurea. The values were all in the region for the onset of sensitization, with hydroxyurea as the most promising (E 7 1 = -0.552 V). For busulfan and cyclophosphamide no value could be determined, but these compounds are probably less electron-affinic than hydroxyurea. A possible application of chemotherapeutic agents as radiosensitizers is discussed. (author)

  1. SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

    International Nuclear Information System (INIS)

    Carver, R; Popple, R; Benhabib, S; Antolak, J; Sprunger, C; Hogstrom, K

    2014-01-01

    Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10 9 ), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT

  2. SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Carver, R [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Popple, R; Benhabib, S [UniversityAlabama Birmingham, Birmingham, AL (United Kingdom); Antolak, J [Mayo Clinic, Rochester, MN (United States); Sprunger, C [Louisiana State University, Baton Rouge, LA (United States); Hogstrom, K [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Louisiana State University, Baton Rouge, LA (United States)

    2014-06-01

    Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.

  3. Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect

    Science.gov (United States)

    Mahdavi, Hoda; Jabbari, Keyvan; Roayaei, Mahnaz

    2016-01-01

    Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus application on a defect is evaluated. The proposed phantom design improves the capability of film dosimetry for obtaining dose profiles of a patient's anatomical condition. A modeled electron field of a patient with a postmastectomy inward surgical defect was planned. High energy electrons were delivered to the phantom in various settings, including no bolus, a bolus that filled the inward defect (PB0), a uniform thickness bolus of 5 mm (PB1), and two 5 mm boluses (PB2). A reduction of mean doses at the base of the defect was observed by any bolus application. PB0 increased the dose at central parts of the defect, reduced hot areas at the base of steep edges, and reduced dose to the lung and heart. Thermoplastic boluses that compensate a defect (PB0) increased the homogeneity of dose in a fixed depth from the surface; adversely, PB2 increased the dose heterogeneity. This study shows that it is practical to investigate dose homogeneity profiles inside a target volume for various techniques of electron therapy. PMID:27051169

  4. An ontology-based annotation of cardiac implantable electronic devices to detect therapy changes in a national registry.

    Science.gov (United States)

    Rosier, Arnaud; Mabo, Philippe; Chauvin, Michel; Burgun, Anita

    2015-05-01

    The patient population benefitting from cardiac implantable electronic devices (CIEDs) is increasing. This study introduces a device annotation method that supports the consistent description of the functional attributes of cardiac devices and evaluates how this method can detect device changes from a CIED registry. We designed the Cardiac Device Ontology, an ontology of CIEDs and device functions. We annotated 146 cardiac devices with this ontology and used it to detect therapy changes with respect to atrioventricular pacing, cardiac resynchronization therapy, and defibrillation capability in a French national registry of patients with implants (STIDEFIX). We then analyzed a set of 6905 device replacements from the STIDEFIX registry. Ontology-based identification of therapy changes (upgraded, downgraded, or similar) was accurate (6905 cases) and performed better than straightforward analysis of the registry codes (F-measure 1.00 versus 0.75 to 0.97). This study demonstrates the feasibility and effectiveness of ontology-based functional annotation of devices in the cardiac domain. Such annotation allowed a better description and in-depth analysis of STIDEFIX. This method was useful for the automatic detection of therapy changes and may be reused for analyzing data from other device registries.

  5. The use of electronic games in therapy: a review with clinical implications.

    Science.gov (United States)

    Horne-Moyer, H Lynn; Moyer, Brian H; Messer, Drew C; Messer, Elizabeth S

    2014-12-01

    Therapists and patients enjoy and benefit from interventions that use electronic games (EG) in health care and mental health settings, with a variety of diagnoses and therapeutic goals. We reviewed the use of electronic games designed specifically for a therapeutic purpose, electronic games for psychotherapy (EGP), also called serious games, and commercially produced games used as an adjunct to psychotherapy, electronic games for entertainment (EGE). Recent research on the benefits of EG in rehabilitation settings, EGP, and EGE indicates that electronic methods are often equivalent to more traditional treatments and may be more enjoyable or acceptable, at least to some consumers. Methodological concerns include the lack of randomized controlled trials (RCT) for many applications. Suggestions are offered for using EG in therapeutic practice.

  6. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  7. Upper gastrointestinal tract injuries by intraoperative radiotherapy for pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tabata, I; Isawa, T; Satomi, T; Tazima, T [Tokyo Metropolitan Komagome Hospital (Japan)

    1981-08-01

    Twenty-one patients with unresectable carcinoma of the pancreas were treated by intraoperative irradiation with a large electron dose of 1500 - 3000 rads and upper gastrointestinal complications were encountered in five cases. All of those five cases were for carcinoma of the pancreatic head, and were seen for gastrointestinal tract injuries of the duodenum as follows, gastric ulcer in 2 cases, ulcer of the 1st duodenal portion in one case and ulcer with severe stenosis of the 2nd or 3rd duodenal portion in one case, respectively. Endoscopic features of these postirradiation gastrointestinal ulcers were characterized by deep, punched-out ulcers with grayish bases and sharp margins. Clinically these ulcers and stenosis were very difficult to treat, so by-pass operations were performed in two cases, resulting in prolonged survival.

  8. Intraoperative radiation in the canine para-aortic abdomen

    International Nuclear Information System (INIS)

    Hoopes, P.J.; Gillette, E.L.

    1984-01-01

    Twenty adult beagle dogs received intraoperatively delivered 6 MeV electrons to the para-aortic abdomen and bladder. The dogs were equally divided into 4 dose groups receiving 22 Gy, 30 Gy, 38.5 Gy and 47 Gy. The 5 cm x 8 cm radiation field included a variable portion of the left kidney, the left ureter, the abdominal aorta and vena cava, the base of the bladder and the left sciatic and femoral nerves. The lesions observed were fibroelastic proliferation of the aortic intima, severe renal atrophy and fibrosis, ureteral stenosis, bladder fibrosis and demyelinating peripheral neuropathies. Histologic, morphometric and dose response analyses are compared with responses of dogs receiving more conventional fractionated doses to a total of 60 Gy, 70 Gy or 80 Gy x-ray in 6 weeks

  9. Utility of intraoperative diagnostic C-arm angiography for management of high grade subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Zhikui Wei

    2015-06-01

    Full Text Available The accurate and efficient localization of underlying vascular lesions is crucial for prompt and definitive treatment of subarachnoid hemorrhage (SAH. To demonstrate the utility and feasibility of intraoperative C-arm angiography in cerebrovascular emergencies, we report five cases of high grade SAH and/or intracerebral hemorrhage (ICH where intraoperative diagnostic C-arm angiography was safely and effectively utilized. Initial evaluations of all patients included a non-contrast head CT scan, which was followed by urgent decompressive hemicraniectomy as a life-saving measure in the presence of markedly elevated intracranial pressure. Further diagnostic evaluations were performed intraoperatively using a multi-purpose C-arm angiography system. The C-arm angiography findings greatly aided the intraoperative planning and led to definitive treatments in four cases of SAH by elucidating the underlying neurovascular lesions. With this treatment strategy, two of the patients made moderately good recoveries from their SAH and/or ICH with a Glasgow outcome score (GOS of 4. Three of the patients expired despite maximal therapy mostly due to unfavorable presenting grade. These results suggest that C-arm angiography is a reasonable diagnostic and surgical planning tool for selected patients with high grade diffuse SAH who require immediate decompression.

  10. Intraoperative real-time planned conformal prostate brachytherapy: Post-implantation dosimetric outcome and clinical implications

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Yamada, Yoshiya; Cohen, Gil'ad N.; Sharma, Neha; Shippy, Alison M.; Fridman, David; Zaider, Marco

    2007-01-01

    Purpose: To report the dosimetric outcome of patients with clinically localized prostate cancer treated with I-125 permanent implantation using an intraoperative real-time conformal planning technique. Methods and materials: Five hundred and sixty-two patients with prostate cancer were treated with I-125 permanent interstitial implantation using a transrectal ultrasound-guided approach. Real-time intraoperative treatment planning software that incorporates inverse planning optimization was used. Dose-volume constraints for this inverse-planning system included: prostate V100 ≥95%, maximal urethral dose ≤120%, and average rectal dose 3 of the rectum was exposed to the prescription dose, the incidence of late grade 2 toxicity rectal toxicity was 9% compared to 4% for smaller volumes of the rectum exposed to similar doses (p = 0.003). No dosimetric parameter in these patients with tight dose confines for the urethra influenced acute or late urinary toxicity. Conclusion: Real-time intraoperative planning was associated with a 90% consistency of achieving the planned intraoperative dose constraints for target coverage and maintaining planned urethral and rectal constraints in a high percentage of implants. Rectal volumes of ≥2.5 cm 3 exposed to the prescription doses were associated with an increased incidence of grade 2 rectal bleeding. Further enhancements in imaging guidance for optimal seed deposition are needed to guarantee optimal dose distribution for all patients. Whether such improvements lead to further reduction in acute and late morbidities associated with therapy requires further study

  11. Total skin electron beam therapy for cutaneous T-cell lymphoma: a nationwide cohort study from Denmark

    DEFF Research Database (Denmark)

    Lindahl, Lise M; Kamstrup, Maria Rørbæk; Petersen, Peter M

    2011-01-01

    Background. Total skin electron beam therapy (TSEBT) is an effective palliative treatment for cutaneous T-cell lymphoma (CTCL). In the present study we reviewed the clinical response to TSEBT in Danish patients with CTCL. Material and methods. This retrospective study included 35 patients with CTCL...... to treatment compared to patients treated with high-dose. Consequently the study with low-dose was discontinued and published. In patients treated with high-dose the overall response rate was 100%. Complete response (CR) rate was 68% and CR occurred after a median time of 2.1 months (range 1.8 months-2.0 years...

  12. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Büchel, Gabriel E.

    2016-08-03

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Shaffer, Travis M.; Tang, Jun; Austin, Christine; Arora, Manish; Zeglis, Brian M.; Grimm, Jan; Eppinger, Jö rg; Reiner, Thomas

    2016-01-01

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Intraoperative dynamic dosimetry for prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Todor, D A [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zaider, M [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Cohen, G N [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Worman, M F [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zelefsky, M J [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States)

    2003-05-07

    This paper describes analytic tools in support of a paradigm shift in brachytherapy treatment planning for prostate cancer - a shift from standard pre-planning to intraoperative planning using dosimetric feedback based on the actual deposited seed positions within the prostate. The method proposed is guided by several desiderata: (a) bringing both planning and evaluation in the operating room (i.e. make post-implant evaluation superfluous) therefore making rectifications - if necessary - still achievable; (b) making planning and implant evaluation consistent by using the same imaging system (ultrasound); and (c) using only equipment commonly found in a hospital operating room. The intraoperative dosimetric evaluation is based on the fusion between ultrasound images and 3D seed coordinates reconstructed from fluoroscopic projections. Automatic seed detection and registration of the fluoroscopic and ultrasound information, two of the three key ingredients needed for the intraoperative dynamic dosimetry optimization (IDDO), are explained in detail. The third one, the reconstruction of 3D coordinates from projections, was reported in a previous article. The algorithms were validated using a custom-designed phantom with non-radioactive (dummy) seeds. Also, fluoroscopic images were taken at the conclusion of an actual permanent prostate implant and compared with data on the same patient obtained from radiographic-based post-implant evaluation. To offset the effect of organ motion the comparison was performed in terms of the proximity function of the two seed distributions. The agreement between the intra- and post-operative seed distributions was excellent.

  15. Multispectral open-air intraoperative fluorescence imaging.

    Science.gov (United States)

    Behrooz, Ali; Waterman, Peter; Vasquez, Kristine O; Meganck, Jeff; Peterson, Jeffrey D; Faqir, Ilias; Kempner, Joshua

    2017-08-01

    Intraoperative fluorescence imaging informs decisions regarding surgical margins by detecting and localizing signals from fluorescent reporters, labeling targets such as malignant tissues. This guidance reduces the likelihood of undetected malignant tissue remaining after resection, eliminating the need for additional treatment or surgery. The primary challenges in performing open-air intraoperative fluorescence imaging come from the weak intensity of the fluorescence signal in the presence of strong surgical and ambient illumination, and the auto-fluorescence of non-target components, such as tissue, especially in the visible spectral window (400-650 nm). In this work, a multispectral open-air fluorescence imaging system is presented for translational image-guided intraoperative applications, which overcomes these challenges. The system is capable of imaging weak fluorescence signals with nanomolar sensitivity in the presence of surgical illumination. This is done using synchronized fluorescence excitation and image acquisition with real-time background subtraction. Additionally, the system uses a liquid crystal tunable filter for acquisition of multispectral images that are used to spectrally unmix target fluorescence from non-target auto-fluorescence. Results are validated by preclinical studies on murine models and translational canine oncology models.

  16. Intraoperative lung ultrasound: A clinicodynamic perspective

    Directory of Open Access Journals (Sweden)

    Amit Kumar Mittal

    2016-01-01

    Full Text Available In the era of evidence-based medicine, ultrasonography has emerged as an important and indispensable tool in clinical practice in various specialties including critical care. Lung ultrasound (LUS has a wide potential in various surgical and clinical situations for timely and easy detection of an impending crisis such as pulmonary edema, endobronchial tube migration, pneumothorax, atelectasis, pleural effusion, and various other causes of desaturation before it clinically ensues to critical level. Although ultrasonography is frequently used in nerve blocks, airway handling, and vascular access, LUS for routine intraoperative monitoring and in crisis management still necessitates recognition. After reviewing the various articles regarding the use of LUS in critical care, we found, that LUS can be used in various intraoperative circumstances similar to Intensive Care Unit with some limitations. Except for few attempts in the intraoperative detection of pneumothorax, LUS is hardly used but has wider perspective for routine and crisis management in real-time. If anesthesiologists add LUS in their routine monitoring armamentarium, it can assist to move a step ahead in the dynamic management of critically ill and high-risk patients.

  17. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Su, Shiqin [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Moran, Kathryn [Queen Elizabeth II Health Sciences Centre, Nova Scotia Cancer Centre, Halifax, Nova Scotia (Canada); Robar, James L. [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia (Canada)

    2014-08-15

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues.

  18. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    International Nuclear Information System (INIS)

    Su, Shiqin; Moran, Kathryn; Robar, James L.

    2014-01-01

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues

  19. Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, John P., E-mail: john.gibbons@marybird.com [Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana 70809 (United States); Antolak, John A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Followill, David S. [Department of Radiation Physics, UT M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania 15232 (United States); Klein, Eric E. [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Lam, Kwok L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Palta, Jatinder R. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Roback, Donald M. [Department of Radiation Oncology, Cancer Centers of North Carolina, Raleigh, North Carolina 27607 (United States); Reid, Mark [Department of Medical Physics, Fletcher-Allen Health Care, Burlington, Vermont 05401 (United States); Khan, Faiz M. [Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2014-03-15

    A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D{sub 0}{sup ′}, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D{sub 0}{sup ′} = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D{sub 0}{sup ′} ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d{sub m}, with D{sub 0}{sup ′} = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

  20. Use of EGS4 codes system for the evaluation of electron contamination in telecobalt therapy unit

    International Nuclear Information System (INIS)

    Bernal, B.; Alfonso, R.

    1995-01-01

    The cobalt 60 beams employed radiotherapy usually have some electron contamination, mainly depending on the selected field size, the diaphragm-skin distance and the collation system features. The electron component of a thyratron 780C cobalt unit was evaluated, using in any material and geometry, by using Monte Carlo techniques. The radiation transport in the unit head was simulated, as well as the absorbed dose in a water phantom, so the surface dose fraction due to electron was computed. Measurements from 0 to 5 mm depth were carried out in order to confirm our calculations, finding good agreement with them. Several PMMA filters with different thickness were analyzed to study their role in the electron contamination reduction; an optimal thickness around 5 mm was found

  1. Relationship between chromatin structure and sensitivity to molecularly targeted auger electron radiation therapy.

    NARCIS (Netherlands)

    Terry, S.Y.A.; Vallis, K.A.

    2012-01-01

    PURPOSE: The open structure of euchromatin renders it susceptible to DNA damage by ionizing radiation (IR) compared with compact heterochromatin. The effect of chromatin configuration on the efficacy of Auger electron radiotherapy was investigated. METHODS AND MATERIALS: Chromatin structure was

  2. Measurement assurance studies of high-energy electron and photon dosimetry in radiation-therapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Ehrlich, M; Soares, C G [National Bureau of Standards, Washington, DC (USA)

    1981-08-01

    This is a brief review of surveys on the dosimetry of radiation-therapy beams by the National Bureau of Standards (NBS). Covered are the NBS ferrous-sulfate (Fricke) dosimetry service, a recently completed survey carried out with thermoluminescence dosimeters (TLD) on the dosimetry in cobalt-60 teletherapy beams, and plans for a TLD survey of dosimetry in high-energy bremsstrahlung beams.

  3. Long-term benefit of electron beam radiation therapy in the treatment of scleredema of Buschke

    Directory of Open Access Journals (Sweden)

    Tijana Skrepnik, MD

    2016-01-01

    Conclusion: Scleredema of Buschke is a rare connective tissue disorder commonly treated with multimodal therapy, but it can be effectively and durably controlled with RT alone. This case report documents the durability of the benefit achieved with RT and suggests that RT should be considered earlier in the treatment of this disease.

  4. Dose volume relationships for intraoperatively irradiated saphenous nerve

    International Nuclear Information System (INIS)

    Gillette, E.L.; Powers, B.E.; Gillette, S.M.; Thames, H.D.; Childs, G.; Vujaskovic, Z.; LaRue, S.M.

    1995-01-01

    Purpose/Objective: Intraoperative radiation therapy (IORT) is used to deliver high single doses of radiation to the tumor bed following surgical removal of various abdominal malignancies. The advantage of IORT is the ability to remove sensitive normal tissues from the treatment field and to limit the volume of normal tissue irradiated. The purpose of this study was to determine dose-volume relationships for retroperitoneal tissues. Materials and methods: 134 adult beagle dogs were irradiated to the surgically exposed paraaortic area. Normal tissues included in the treatment field were aorta, peripheral nerve, ureter, bone and muscle. Groups of 4 - 8 dogs were irradiated to doses ranging from 18 - 54 Gy for a 2x5 cm field, from 12 - 46 Gy for a 4x5 cm field, and 12 - 42 Gy to an 8x5 cm field. The radiations were done using 6 MeV electrons from a linear accelerator. Dogs were observed for three years after radiation. Electrophysiologic procedures were done prior to irradiation and annually following irradiation. The procedures included electromyography of the pelvic limb and paralumbar muscles supplied by the L1 to S1 spinal nerves to determine presence and degree of motor unit disease. Motor nerve conduction velocities of the proximal and distal sciatic nerves were determined. Sensory nerve conduction velocities of the saphenous nerve were also determined. Evoked lumbosacral and thoraco-lumbar spinal cord potentials were evaluated following stimulation of the left sciatic nerve. In addition to electrophysiologic studies, neurologic examinations were done prior to treatment and at six month intervals for the three year observation period. At the three year time period, dogs were euthanatized, sections of peripheral nerve taken, routinely processed, stained with Masson's trichrome and evaluated histomorphometrically using point count techniques. Results: Twenty-two dogs were euthanatized prior to the three year observation period due to peripheral nerve damage

  5. Evaluation of a mixed beam therapy for post-mastectomy breast cancer patients: bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.

    Science.gov (United States)

    Zhang, Rui; Heins, David; Sanders, Mary; Guo, Beibei; Hogstrom, Kenneth

    2018-05-10

    The purpose of this study was to assess the potential benefits and limitations of a mixed beam therapy, which combined bolus electron conformal therapy (BECT) with intensity modulated photon radiotherapy (IMRT) and volumetric modulated photon arc therapy (VMAT), for left-sided post-mastectomy breast cancer patients. Mixed beam treatment plans were produced for nine post-mastectomy radiotherapy (PMRT) patients previously treated at our clinic with VMAT alone. The mixed beam plans consisted of 40 Gy to the chest wall area using BECT, 40 Gy to the supraclavicular area using parallel opposed IMRT, and 10 Gy to the total planning target volume (PTV) by optimizing VMAT on top of the BECT+IMRT dose distribution. The treatment plans were created in a commercial treatment planning system (TPS), and all plans were evaluated based on PTV coverage, dose homogeneity index (DHI), conformity index (CI), dose to organs at risk (OARs), normal tissue complication probability (NTCP), and secondary cancer complication probability (SCCP). The standard VMAT alone planning technique was used as the reference for comparison. Both techniques produced clinically acceptable PMRT plans but with a few significant differences: VMAT showed significantly better CI (0.70 vs. 0.53, p 0.5 cm and volume of tissue between the distal PTV surface and heart or lung approximately > 250 cm 3 ) between distal PTV surface and lung may benefit the most from mixed beam therapy. This work has demonstrated that mixed beam therapy (BECT+IMRT : VMAT = 4 : 1) produces clinically acceptable plans having reduced OAR doses and risks of side effects compared with VMAT. Even though VMAT alone produces more homogenous and conformal dose distributions, mixed beam therapy remains as a viable option for treating post-mastectomy patients, possibly leading to reduced normal tissue complications. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Breast-conserving radiation therapy using combined electron and intensity-modulated radiotherapy technique

    International Nuclear Information System (INIS)

    Li, J.G.; Williams, S.S.; Goffinet, D.R.; Boer, A.L.; Xing, L.

    2000-01-01

    An electron beam with appropriate energy was combined with four intensity modulated photon beams. The direction of the electron beam was chosen to be tilted 10-20 laterally from the anteroposterior direction. Two of the intensity-modulated photon beams had the same gantry angles as the conventional tangential fields, whereas the other two beams were rotated 15-25' toward the anteroposterior directions from the first two photon beams. An iterative algorithm was developed which optimizes the weight of the electron beam as well as the fluence profiles of the photon beams for a given patient. Two breast cancer patients with early-stage breast tumors were planned with the new technique and the results were compared with those from 3D planning using tangential fields as well as 9-field intensity-modulated radiotherapy (IMRT) techniques. The combined electron and IMRT plans showed better dose conformity to the target with significantly reduced dose to the ipsilateral lung and, in the case of the left-breast patient, reduced dose to the heart, than the tangential field plans. In both the right-sided and left-sided breast plans, the dose to other normal structures was similar to that from conventional plans and was much smaller than that from the 9-field IMRT plans. The optimized electron beam provided between 70 to 80% of the prescribed dose at the depth of maximum dose of the electron beam. The combined electron and IMRT technique showed improvement over the conventional treatment technique using tangential fields with reduced dose to the ipsilateral lung and the heart. The customized beam directions of the four IMRT fields also kept the dose to other critical structures to a minimum. (author)

  7. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    Science.gov (United States)

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  8. Complication of Intraoperative Radiation Therapy (IORT) in Gastric Cancer

    International Nuclear Information System (INIS)

    Kim, Myung Se; Kim, Sung Kyu; Song, Sung Kyo; Kim, Hong Jin; Kwan, Koing Bo; Kim, Heung Dae

    1992-01-01

    Local control is the important prognostic factor in cancer treatment because local control decrease the relative risk of metastatic spread and increase distant metastasis free survival. IORT is the modality which could increase local control without increasing complication, combined with curative operation. Even though we could achieve significant decreased local failure by IORT and curative resection, it should not be committed as a main treatment modality without proving acceptable complications. Therapeutic Radiology Department of Yeungnam University Medical Center have tried 58 IORT from June 15, 1988, and performed 53 IORT in patients with gastric cancer. No local failure has been report? by regular follow up so far. Nine cases(17%) of treatment related complication were reported including intestinal obstruction, hemorrhage, sepsis, and bone marrow depression. These complications could be comparable to Jo 25.2% (chemotherapy + operation), Kim 18% (chemotherapy only in inoperable patients), because our treatment regimen is consisted of IORT (1500 cGy), external irradiation(--4500 cGy) and extensive chemotherapy (FAM, 5FU+MMC, BACOP). Our data encouraged us to re-inforce further IORT in stomach cancer treatment

  9. Complication of Intraoperative Radiation Therapy (IORT) in Gastric Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Se; Kim, Sung Kyu; Song, Sung Kyo; Kim, Hong Jin; Kwan, Koing Bo; Kim, Heung Dae [Yeungnam University College of Medicine, Taegu (Korea, Republic of)

    1992-12-15

    Local control is the important prognostic factor in cancer treatment because local control decrease the relative risk of metastatic spread and increase distant metastasis free survival. IORT is the modality which could increase local control without increasing complication, combined with curative operation. Even though we could achieve significant decreased local failure by IORT and curative resection, it should not be committed as a main treatment modality without proving acceptable complications. Therapeutic Radiology Department of Yeungnam University Medical Center have tried 58 IORT from June 15, 1988, and performed 53 IORT in patients with gastric cancer. No local failure has been report? by regular follow up so far. Nine cases(17%) of treatment related complication were reported including intestinal obstruction, hemorrhage, sepsis, and bone marrow depression. These complications could be comparable to Jo 25.2% (chemotherapy + operation), Kim 18% (chemotherapy only in inoperable patients), because our treatment regimen is consisted of IORT (1500 cGy), external irradiation(--4500 cGy) and extensive chemotherapy (FAM, 5FU+MMC, BACOP). Our data encouraged us to re-inforce further IORT in stomach cancer treatment.

  10. Preliminary results of the Gas Electron Multiplier (GEM) as real-time beam monitor in hadron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Aza, E., E-mail: eleni.aza@cern.ch [CERN, Geneva 23, 1211 Geneva (Switzerland); AUTH, Department of Physics, 54124 Thessaloniki (Greece); Ciocca, M. [Fondazione CNAO, Strada Campeggi 53, 27100 Pavia (Italy); Murtas, F. [CERN, Geneva 23, 1211 Geneva (Switzerland); LNF-INFN, Via Fermi 40, 00044 Frascati (Italy); Puddu, S. [CERN, Geneva 23, 1211 Geneva (Switzerland); AEC-LHEP, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Pullia, M. [Fondazione CNAO, Strada Campeggi 53, 27100 Pavia (Italy); Silari, M. [CERN, Geneva 23, 1211 Geneva (Switzerland)

    2017-01-01

    The use of proton and carbon ion beams in cancer therapy (also known as hadron therapy) is progressively growing worldwide due to their improved dose distributions, sparing of healthy tissues and (for carbon ions) increased radiobiological effectiveness especially for radio-resistant tumours. Strict Quality Assurance (QA) protocols need to be followed for guaranteeing the clinical beam specifications. The aim of this study was to assess the performance of a gaseous detector based on the Gas Electron Multiplier (GEM) technology for measuring the beam spot dimensions and the homogeneity of the scanned irradiation field, which are daily QA tasks commonly performed using radiochromic films. Measurements performed at the National Centre for Oncological Hadron Therapy (CNAO) in Pavia (Italy) showed that the detector is able to monitor the 2D beam image on-line with a pad granularity of 2 mm and a response proportional to the number of delivered particles. The dose homogeneity was measured with low deviation from the results obtained with radiochromic films.

  11. Experience with high-energy electron beam therapy at the University of Chicago

    International Nuclear Information System (INIS)

    Griem, M.L.; Kuchnir, F.T.; Lanzl, L.H.; Skaggs, L.S.; Sutton, H.G.; Tokars, R.

    1979-01-01

    Current utilization of the linear accelerator as well as 5-year cumulative experience in radiotherapy is presented. Cutaneous lymphomas and mammary gland carcinomas were the prime experience region; however, cancers at other locations were treated with mixed-beam therapy; employing fast neutrons and photon beams. The technique appears promising for abdominal tumors and deep-seated malignancies. Carcinoma of the pancreas responds favorably to this technique

  12. Measurement assurance studies of high-energy electron and photon dosimetry in radiation-therapy applications

    International Nuclear Information System (INIS)

    Ehrlich, M.; Soares, C.G.

    1981-01-01

    This is a brief review of surveys on the dosimetry of radiation-therapy beams by the National Bureau of Standards (NBS). Covered are the NBS ferrous-sulfate (Fricke) dosimetry service, a recently completed survey carried out with thermoluminescence dosimeters (TLD) on the dosimetry in cobalt-60 teletherapy beams, and plans for a TLD survey of dosimetry in high-energy bremsstrahlung beams. (author)

  13. Alteration of the threshold stimulus for intraoperative brain mapping via use of antiepileptic medications

    Directory of Open Access Journals (Sweden)

    John W. Amburgy, MD

    2015-03-01

    Full Text Available Intraoperative seizures during awake craniotomy with cortical and subcortical mapping are a common occurrence. Patients are routinely treated preoperatively with anti-convulsive medications to reduce seizure occurrence. Historically these drugs have not been believed to significantly affect awake craniotomy procedures. We report a patient undergoing intraoperative mapping with differential response and seizure occurrence based upon antiepileptic drug usage. A 43 year old female presented with history of seizures, right sided hemiparesis, electrical sensations, and difficulty with language function. She was determined to have a mass lesion involving the left frontal and temporal lobes and subsequently elected to undergo resection by awake craniotomy with intraoperative mapping. A first attempt at lesion resection was performed after a missed dose of anti-convulsant medication (levetiracetam and was subsequently aborted because of repeated seizure activity. The threshold for seizure generation (1.75 mA was observed to be significantly lower than expected. Therapy was begun with both levetiracetam and phenytoin prior to a second attempted resection one week later. Thresholds for cortical motor response in the second operation were significantly higher than expected (> 9.0 mA, and no intraoperative seizure activity was observed. To our knowledge this is the first quantitative example of antiepileptic drugs affecting the current required for intraoperative mapping. This case highlights the potential for higher current requirements in patients preoperatively treated with high doses of antiepileptic drugs, as well as the importance of confirming adequate dosage of antiepileptic drugs in patients at an increased risk of seizure generation.

  14. Intraoperative plus external beam irradiation in nonresectable lung cancer

    International Nuclear Information System (INIS)

    Arian-Schad, K.S.; Juettner, F.M.; Ratzenhofer, B.; Leitner, H.; Porsch, G.; Pinter, H.; Ebner, F.; Hackl, A.G.; Friehs, G.B.

    1990-01-01

    Since 1987, 24 patients with inoperable non-small-cell lung cancer (NSCLC), stage T 1-3 N 0-2 M 0 , have undergone lymph node dissection and intraoperative radiation therapy (IORT) to the primary with 10-20 Gy. Patient selection criteria were nonresectability based on severe cardiorespiratory impairment, no radiological evidence of distant metastases and a Karnofsky performance status of >80. In 18 patients the IORT procedure was followed by an external beam radiation series (EBR) including the tumor with 46 Gy and the regional lymph nodes with 45/56 Gy. The tumor response was assessed by CAT-scan volumetry before the institution of IORT, 4 weeks later, before the onset of EBR, 8 weeks after the combined treatment course and on a 3 months basis thereafter. Prospectively, MRI of the thorax with/without Gadolinium-DTPA was performed to examine contrast enhancement and signal behavior of the tumor, in an attempt to differentiate residual disease compared to therapy-related collateral damage. So far, 18 patients have completed the combined treatment course with a median follow-up of 11 months (range 4.5 to 25 months). The overall local response rate (CR and PR) was 88.2 per cent. In detail, 11 complete responses, 6 partial responses and one minimal response were observed. The overall and recurrent-free survival at 25 months was 49.6 per cent and 83.3 per cent, respectively. (author). 31 refs.; 2 figs.; 3 tabs

  15. Improved long-term survival after intra-operative single high-dose ATG-Fresenius induction in renal transplantation: a single centre experience.

    Science.gov (United States)

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2009-01-01

    In organ grafts donor-specific sensitization is initiated immediately after revascularization. Therefore, in 1990 we introduced the intra-operative single high-dose ATG-Fresenius (ATG-F) induction in addition to standard triple drug therapy (TDT) consisting of steroids, azathioprine and cyclosporin. A total of 778 first renal transplantations from deceased donors, performed between 1987 and 1998, were included in this evaluation. This retrospective analysis of clinic records and electronic databases presents data of all recipients of first kidney grafts who received two different ATG-F inductions (1(st) group: 9 mg/kg body weight as single high-dose intra-operatively, n=484; 2(nd) group: 3 mg/kg body weight on 7 or 8 consecutive days as multiple-dose starting also intra-operatively, n=78) and standard TDT alone (3(rd) group: TDT alone, n=216). The 10-year patient survival rates were 72.6+/-2.6% (TDT + ATG-F single high-dose), 79.5+/-5.1% (TDT + ATG-F multiple-dose) and 67.2+/-3.7%% (TDT alone; Kaplan-Meier estimates with standard errors; ATG-F vs TDT alone, p=0.001). The 10-year graft survival rates with censoring of patients that died with a functioning graft were 73.8+/-2.4%, 57.7+/-5.8% and 58.4+/-3.6% (Kaplan-Meier estimates with standard errors; 1(st) vs 2(nd )and 3(rd) group, respectively, p<0.001) and the 10-year graft survival rates with patient death counted as graft failure were 58.3+/-2.7%, 55.7+/-5.8% and 48.2+/-3.5% (Kaplan-Meier estimates with standard errors; ATG-F single high-dose vs TDT, p=0.023). In pre-sensitized recipients there were also significant differences in favour of ATG-F, more notably in the single high-dose ATG-F induction. A total of 69% of the patients in the two cohorts receiving ATG-F did not experience any transplant rejections compared to 56% in patients undergoing TDT alone (p=0.018). The incidence of infectious complications was comparable across all groups. According to evidence obtained from the routine documentation of 778

  16. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve: histopathological and morphometric studies

    International Nuclear Information System (INIS)

    Vujaskovic, Zeljko; Powers, Barbara E.; Paardekoper, Gabriel; Gillette, Sharon M.; Gillette, Edward L.; Colacchio, Thomas A.

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate histopathological and histomorphometric changes in the sciatic nerve of dogs, after IORT with or without hyperthermia treatment. Methods and Materials: Young adult beagle dogs were randomized into five groups of 3-5 dogs each to receive IORT doses of 16, 20, 24, 28, or 32 Gy. Six groups of 4-5 dogs each received IORT doses of 12, 16, 20, 24, or 28 Gy simultaneously with 44 deg. C of intraoperative hyperthermia (IOHT) for 60 min. One group of dogs acted as hyperthermia-alone controls. Two years after the treatment, dogs were euthanized, and histopathological and morphometric analyses were performed. Results: Qualitative histological analysis showed prominant changes such as focal necrosis, mineralization, fibrosis, and severe fiber loss in dogs which received combined treatment. Histomorphometric results showed a significantly higher decrease in axon and myelin and small blood vessels, with a corresponding increase in connective tissue in dogs receiving IORT plus hyperthermia treatment. The effective dose for 50% of nerve fiber loss (ED 50 ) in dogs exposed to IORT only was 25.3 Gy. The ED 50 for nerve fiber loss in dogs exposed to IORT combined with IOHT was 14.8 Gy. The thermal enhancement ratio (TER) was 1.7. Conclusion: The probability of developing peripheral neuropathies in a large animal model is higher when IORT is combined with IOHT, when compared to IORT application alone. To minimize the risk of peripheral neuropathy, clinical treatment protocols for the combination of IORT and hyperthermia should not assume a thermal enhancement ratio (TER) to be lower than 1.5

  17. Intraoperative mechanical ventilation: state of the art.

    Science.gov (United States)

    Ball, Lorenzo; Costantino, Federico; Orefice, Giulia; Chandrapatham, Karthikka; Pelosi, Paolo

    2017-10-01

    Mechanical ventilation is a cornerstone of the intraoperative management of the surgical patient and is still mandatory in several surgical procedures. In the last decades, research focused on preventing postoperative pulmonary complications (PPCs), both improving risk stratification through the use of predictive scores and protecting the lung adopting so-called protective ventilation strategies. The aim of this review was to give an up-to-date overview of the currently suggested intraoperative ventilation strategies, along with their pathophysiologic rationale, with a focus on challenging conditions, such as obesity, one-lung ventilation and cardiopulmonary bypass. While anesthesia and mechanical ventilation are becoming increasingly safe practices, the contribution to surgical mortality attributable to postoperative lung injury is not negligible: for these reasons, the prevention of PPCs, including the use of protective mechanical ventilation is mandatory. Mechanical ventilation should be optimized providing an adequate respiratory support while minimizing unwanted negative effects. Due to the high number of surgical procedures performed daily, the impact on patients' health and healthcare costs can be relevant, even when new strategies result in an apparently small improvement of outcome. A protective intraoperative ventilation should include a low tidal volume of 6-8 mL/kg of predicted body weight, plateau pressures ideally below 16 cmH2O, the lowest possible driving pressure, moderate-low PEEP levels except in obese patients, laparoscopy and long surgical procedures that might benefit of a slightly higher PEEP. The work of the anesthesiologist should start with a careful preoperative visit to assess the risk, and a close postoperative monitoring.

  18. Accelerator based Production of Auger-Electron-emitting Isotopes for Radionuclide Therapy

    DEFF Research Database (Denmark)

    Thisgaard, Helge

    Sb from the enriched 119Sn target material with high radionuclidic- and chemical purity. A method that also allows efficient recovery of the 119Sn for recycling. To demonstrate the ability of producing therapeutic quantities of 119Sb and other radioisotopes for therapy with a low-energy cyclotron...... isotopes (e.g. 119Sb or 64Cu) using the PETtrace cyclotron commonly found at the larger PET-centers in the hospitals. Finally, research in a new method to measure the radiotoxicity of Auger-emitters invitro using cellular microinjection has been carried out. The purpose of this method is to be able...

  19. Spinal infection: Evaluation with MR imaging and intraoperative spinal US

    International Nuclear Information System (INIS)

    Donovan Post, M.J.; Montalvo, B.M.; Quencer, R.M.; Katz, B.H.; Green, B.A.; Elsmont, F.

    1987-01-01

    MR spine images and/or intraoperative US scans in 15 patients were reviewed retrospectively and correlated with clinical and pathologic data to determine the diagnostic value of these modalities in spinal infection. In osteomyelitis and retrospinal abscess MR imaging was definitive; in myelitis it was positive but nonspecific. In epidural abscess concomitant with meningitis, myelography with CT and intraoperative US were superior to MR imaging. Intraoperative US could be used to distinguish these processes and to monitor surgical decompression. The authors recommend that MR imaging be performed at the screening examination in cases of spinal infection, accompanied by intraoperative US in all surgical cases

  20. In vivo virtual intraoperative surgical photoacoustic microscopy

    International Nuclear Information System (INIS)

    Han, Seunghoon; Kim, Sehui; Kim, Jeehyun; Lee, Changho; Jeon, Mansik; Kim, Chulhong

    2013-01-01

    We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo

  1. In vivo virtual intraoperative surgical photoacoustic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seunghoon, E-mail: hsh860504@gmail.com; Kim, Sehui, E-mail: sehui0916@nate.com; Kim, Jeehyun, E-mail: jeehk@knu.ac.kr, E-mail: chulhong@postech.edu [School of Electrical Engineering and Computer Science, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Lee, Changho, E-mail: ch31037@postech.edu; Jeon, Mansik, E-mail: msjeon@postech.edu [Department of Creative IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784 (Korea, Republic of); Kim, Chulhong, E-mail: jeehk@knu.ac.kr, E-mail: chulhong@postech.edu [Department of Creative IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784 (Korea, Republic of); Department of Biomedical Engineering, The State University of New York at Buffalo, Buffalo, New York 14221 (United States)

    2013-11-11

    We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo.

  2. Simultaneous delivery of electron beam therapy and ultrasound hyperthermia using scanning reflectors: a feasibility study

    International Nuclear Information System (INIS)

    Moros, Eduardo G.; Straube, William L.; Klein, Eric E.; Yousaf, Muhammed; Myerson, Robert J.

    1995-01-01

    Purpose: The feasibility of simultaneously delivering external electron beam radiation and superficial hyperthermia using a scanning ultrasound reflector-array system (SURAS) was experimentally investigated and demonstrated. Methods and Materials: A new system uses a scanning reflector to distribute the acoustic energy from a planar ultrasound array over the surface of the target volume. External photon/electron beams can be concurrently delivered with hyperthermia by irradiating through the scanning reflectors. That is, this system enables the acoustic waves and the radiation beams to enter the target volume from the same direction. Reflectors were constructed of air-equivalent materials for maximum acoustic reflection and minimum radiation attenuation. Acoustically, the air reflectors were compared to brass reflectors (assumed ideal) for reflectivity and specular quality using several single transducers ranging in frequency from 0.68 to 4.8 MHz. The relative reflectivity was determined from acoustic power measurements using a force-balance technique. The specular quality was assessed by comparing the acoustic pressure fields reflected by air reflectors with those reflected by brass reflectors. Also, acoustic pressure fields generated by a SURAS prototype for two different arrays (2.24 and 4.5 MHz) were measured to investigate field distribution variations as a function of the distance separating the array and the scanning reflector. All pressure fields were measured with a hydrophone in a degassed water tank. Finally, to determine the effect of the air reflectors on electron dose distributions, these were measured using film in a water-equivalent solid phantom after passage of a 20 MeV electron beam through the SURAS. These measurements were performed with the reflector scanning continuously across the electron beam and at rest within the electron beam. Results: The measurements performed using single ultrasound transducers showed that the air reflectors had

  3. Electronics

    Science.gov (United States)

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  4. Design study of electron cyclotron resonance-ion plasma accelerator for heavy ion cancer therapy

    International Nuclear Information System (INIS)

    Inoue, T.; Sugimoto, S.; Sasai, K.; Hattori, T.

    2014-01-01

    Electron Cyclotron Resonance-Ion Plasma Accelerator (ECR-IPAC) device, which theoretically can accelerate multiple charged ions to several hundred MeV with short acceleration length, has been proposed. The acceleration mechanism is based on the combination of two physical principles, plasma electron ion adiabatic ejection (PLEIADE) and Gyromagnetic Autoresonance (GYRAC). In this study, we have designed the proof of principle machine ECR-IPAC device and simulated the electromagnetic field distribution generating in the resonance cavity. ECR-IPAC device consisted of three parts, ECR ion source section, GYRAC section, and PLEIADE section. ECR ion source section and PLEIADE section were designed using several multi-turn solenoid coils and sextupole magnets, and GYRAC section was designed using 10 turns coil. The structure of ECR-IPAC device was the cylindrical shape, and the total length was 1024 mm and the maximum diameter was 580 mm. The magnetic field distribution, which maintains the stable acceleration of plasma, was generated on the acceleration center axis throughout three sections. In addition, the electric field for efficient acceleration of electrons was generated in the resonance cavity by supplying microwave of 2.45 GHz

  5. Brain tumors in eloquent areas: A European multicenter survey of intraoperative mapping techniques, intraoperative seizures occurrence, and antiepileptic drug prophylaxis.

    Science.gov (United States)

    Spena, Giannantonio; Schucht, Philippe; Seidel, Kathleen; Rutten, Geert-Jan; Freyschlag, Christian Franz; D'Agata, Federico; Costi, Emanule; Zappa, Francesca; Fontanella, Marco; Fontaine, Denys; Almairac, Fabien; Cavallo, Michele; De Bonis, Pasquale; Conesa, Gerardo; Foroglou, Nicholas; Gil-Robles, Santiago; Mandonnet, Emanuel; Martino, Juan; Picht, Thomas; Viegas, Catarina; Wager, Michel; Pallud, Johan

    2017-04-01

    Intraoperative mapping and monitoring techniques for eloquent area tumors are routinely used world wide. Very few data are available regarding mapping and monitoring methods and preferences, intraoperative seizures occurrence and perioperative antiepileptic drug management. A questionnaire was sent to 20 European centers with experience in intraoperative mapping or neurophysiological monitoring for the treatment of eloquent area tumors. Fifteen centers returned the completed questionnaires. Data was available on 2098 patients. 863 patients (41.1%) were operated on through awake surgery and intraoperative mapping, while 1235 patients (58.8%) received asleep surgery and intraoperative electrophysiological monitoring or mapping. There was great heterogeneity between centers with some totally AW oriented (up to 100%) and other almost totally ASL oriented (up to 92%) (31% SD). For awake surgery, 79.9% centers preferred an asleep-awake-asleep anesthesia protocol. Only 53.3% of the centers used ECoG or transcutaneous EEG. The incidence of intraoperative seizures varied significantly between centers, ranging from 2.5% to 54% (p mapping technique and the risk of intraoperative seizures. Moreover, history of preoperative seizures can significantly increase the risk of intraoperative seizures (p mapping and monitoring protocols and the management of peri- and intraoperative seizures. This data can help identify specific aspects that need to be investigated in prospective and controlled studies.

  6. TU-CD-304-07: Intensity Modulated Electron Beam Therapy Employing Small Fields in Virtual Scanning Mode

    International Nuclear Information System (INIS)

    Rodrigues, A; Yin, F; Wu, Q; Liang, B

    2015-01-01

    Purpose: Dynamic electron radiation therapies such as dynamic electron arc radiotherapy (DEAR) utilize small fields to provide target conformity and fluence modulation. The purpose of this study is to demonstrate the feasibility of virtual scanning mode using small fields. Methods: Monte Carlo simulations (EGSnrc/BEAMnrc/DOSXYZnrc) were performed using validated Varian TrueBeam phase space files for electron beam energies of 6, 9, 12, and 16 MeV and square/circular fields (1×1/1, 2×2/2, 3×3/3, 4×4/4, 5×5/5 cm"2/cm diameter). Resulting dose distributions (kernels) were used for subsequent calculations. The following analyses were performed: (1) Comparison of composite square fields and reference 10×10 cm"2 dose distributions and (2) Scanning beam deliveries for square and circular fields realized as the convolution of kernels and scanning pattern. Preliminary beam weight and pattern optimization were also performed. Two linear scans of 10 cm with/without overlap were modeled. Comparison metrics included depth and orthogonal profiles at dmax. Results: (1) Composite fields regained reference depth dose profiles for most energies and fields within 5%. Smaller kernels and higher energies increased dose in the build-up and Bremsstrahlung region (30%, 16MeV and 1×1 cm"2), while reference dmax was maintained for all energies and composite fields. Smaller kernels (<2×2 cm"2) maintained penumbra and field size within 0.2 cm, and flatness within 2%. Deterioration of penumbra for larger kernels (5×5 cm"2) were observed. Balancing desirable dosimetry and efficiencies suggests that smaller kernels are used at edges and larger kernels in the center of the target. (2) Beam weight optimization improved cross-plane penumbra (0.2 cm) and increased the field size (0.4 cm) on average. In-plane penumbra and field size remained unchanged. Overlap depended on kernel size and optimal overlap resulted in flatness ±2%. Conclusion: Dynamic electron beam therapy in virtual scanning

  7. Intraoperative radiotherapy in the management of esophageal and gastro-esophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Suh, David; Ahmad, Neelofur; Huq, M Saiful; Mohiuddin, Mohammed; Cohn, Herbert; Barbot, Donna; Rosato, Francis

    1995-07-01

    Purpose: Patients with esophageal and gastro-esophageal junction (GEJ) carcinomas suffer a high rates of local regional failure following conventional therapies. This report describes a unique institutional experience with the use of intraoperative radiation therapy (IORT) in the multimodality management of these tumors. Methods and Materials: From January, 1989 through August, 1994, 22 patients with distal esophageal(n=8) or GEJ junction carcinomas (n=14) underwent surgery followed by IORT to the tumor bed. Two patients died perioperatively of complications unrelated to the IORT and were excluded from the study. In the remaining 20 patients, IORT doses ranged from 12 to 20 Gy (median 15 Gy). The electron energies ranged from 4 to 22 MeV (median 6 MeV). Ten patients received no further radiation therapy (IORT only group), and ten patients received adjuvant external beam radiation (IORT + EB group) ranging from 39.6 to 60.8 Gy (median 45.0 Gy) in standard fractionation. 5-FU-based chemotherapy was administered to 15 patients either pre- or postoperatively. Follow-up ranged from 4 to 62 months (median 10 months). Results: The overall median survival time (MST) was 10 months. The overall 2-year actuarial survival rate was 25%. Distant metastasis developed in (9(20)) patients. The results by treatment subgroups are listed below. There was 1 local failure each in the IORT only group and the IORT+EB group. There were no perioperative complications related to IORT. The average length of hospital stay did not appear different than that of patients not receiving IORT. Conclusions: This is the first North American series describing the use of IORT after resection of esophageal/GEJ carcinomas. The use of IORT in our study did not increase perioperative morbidity over that reported for patients undergoing surgery alone. The addition of EBRT was associated with a longer median survival time although not with improved long-term survival when compared to the outcome of patients

  8. Intraoperative MRI in pediatric brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choudhri, Asim F. [Le Bonheur Children' s Hospital, Department of Radiology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Neurosurgery, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Ophthalmology, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Siddiqui, Adeel [University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Klimo, Paul; Boop, Frederick A. [University of Tennessee Health Science Center, Department of Neurosurgery, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Semmes-Murphey Neurologic and Spine Institute, Memphis, TN (United States); St. Jude Children' s Hospital, Division of Neurosurgery, Department of Surgery, Memphis, TN (United States)

    2015-09-15

    Intraoperative magnetic resonance imaging (iMRI) has emerged as an important tool in guiding the surgical management of children with brain tumors. Recent advances have allowed utilization of high field strength systems, including 3-tesla MRI, resulting in diagnostic-quality scans that can be performed while the child is on the operating table. By providing information about the possible presence of residual tumor, it allows the neurosurgeon to both identify and resect any remaining tumor that is thought to be safely accessible. By fusing the newly obtained images with the surgical guidance software, the images have the added value of aiding in navigation to any residual tumor. This is important because parenchyma often shifts during surgery. It also gives the neurosurgeon insight into whether any immediate postoperative complications have occurred. If any complications have occurred, the child is already in the operating room and precious minutes lost in transport and communications are saved. In this article we review the three main approaches to an iMRI system design. We discuss the possible roles for iMRI during intraoperative planning and provide guidance to help radiologists and neurosurgeons alike in the collaborative management of these children. (orig.)

  9. Intraoperative MRI in pediatric brain tumors

    International Nuclear Information System (INIS)

    Choudhri, Asim F.; Siddiqui, Adeel; Klimo, Paul; Boop, Frederick A.

    2015-01-01

    Intraoperative magnetic resonance imaging (iMRI) has emerged as an important tool in guiding the surgical management of children with brain tumors. Recent advances have allowed utilization of high field strength systems, including 3-tesla MRI, resulting in diagnostic-quality scans that can be performed while the child is on the operating table. By providing information about the possible presence of residual tumor, it allows the neurosurgeon to both identify and resect any remaining tumor that is thought to be safely accessible. By fusing the newly obtained images with the surgical guidance software, the images have the added value of aiding in navigation to any residual tumor. This is important because parenchyma often shifts during surgery. It also gives the neurosurgeon insight into whether any immediate postoperative complications have occurred. If any complications have occurred, the child is already in the operating room and precious minutes lost in transport and communications are saved. In this article we review the three main approaches to an iMRI system design. We discuss the possible roles for iMRI during intraoperative planning and provide guidance to help radiologists and neurosurgeons alike in the collaborative management of these children. (orig.)

  10. [Threefold intraoperative electrophysiological monitoring of vestibular neurectomy].

    Science.gov (United States)

    Hausler, R; Kasper, A

    1991-01-01

    A threefold intraoperative monitoring of facial nerve, auditory nerve and vestibular nerve function was performed in 14 cases of retrosigmoidal neurectomy. The facial nerve was monitoring with a pressure transducer placed against the cheek (Opalarm system). The auditory nerve was monitored with acoustically (click) evoked early potentials and the vestibular nerve was monitored with electrically evoked vestibular potentials obtained by direct stimulation (biphasic current pulses of 0.75-mA p-p, 100 us, 20/s) of the exposed vestibular nerve in the cerebellopontine angle before, during and after neurectomy. A characteristic vertex negative peak having a latency of approximately 2 ms and approximately 0.5 uV amplitude was obtained between a forehead and an ipsilateral ear lobe electrode (2 x 1,000 averaged responses over 10 ms) before the neurectomy. This response disappeared after selective vestibular nerve section proximal to the stimulation site. A diminished response amplitude was measured after incomplete nerve section. Simultaneous acoustic masking had no influence on the vestibular potential. The 14 operated patients became all free of vertiginous spells and drop-attacks except one patient who developed a contralateral Menière's. Facial nerve function remained normal in all. Hearing preservation was obtained in 12 patients (86%). The threefold intraoperative monitoring has turned out to be an additional safety factor for facial and auditory nerve preservation and, thanks to the recording of vestibular potentials, it increased the efficiency of vestibular neurectomy.

  11. Use of electronic music as an occupational therapy modality in spinal cord injury rehabilitation: an occupational performance model.

    Science.gov (United States)

    Lee, B; Nantais, T

    1996-05-01

    This article describes an electronic music program that allows clients with spinal cord injury (SCI) to form musical bands and play songs while performing therapeutic exercise in an occupational therapy program. Clients create the music by activating upper extremity exercise devices that are connected to a synthesizer through a computer. The bands choose the songs they would like to play and meet twice a week for 1 hr to practice. The 8-week program often concludes with a public performance. The music program is intended to motivate client participation in physical rehabilitation while promoting self-esteem, emotional expression, and peer support. It is based on the model of occupational performance and the theory of purposeful activity. To date, 33 persons have taken part. Client, therapist, and public response has been positive because this program highlights the abilities of persons with SCI, thereby encouraging their reintegration into the community.

  12. Hypofractionated electron-beam radiation therapy for keloids. Retrospective study of 568 cases with 834 lesions

    International Nuclear Information System (INIS)

    Shen Jie; Lian Xin; Sun Yuliang

    2015-01-01

    We aimed to analyze the outcomes of hypofractionated high-energy electron beam radiotherapy for the treatment of keloids. From February 1998 to January 2012, 568 patients with a total of 834 keloids underwent radiotherapy: 826 lesions with postoperative radiotherapy, and 36 with skin-grafting. Lesion size was >5 cm in 335 keloids. An electron-beam of 6 or 7 MeV was used, with a total dose of 18 Gy (two fractions with a 1-week interval) covering the lesion with a 1-cm margin. The time between surgery and radiotherapy was 24–48 h. Skin-grafted patients underwent radiotherapy 10–15 days after the operation. The median follow-up was 40 months (range: 12–160 months). The local control rate was 88.25% (736/834). The relapse rate was 9.59% (80/834), and the time to relapse was 6–28 months (median: 12 months). Univariate analyses showed that gender, age, keloid size, keloid site, skin grafting, and operation-to-irradiation interval influenced the local control rate. Multivariate analysis showed that the relapse rate was correlated with gender (P = 0.048), age (P < 0.01), operation-to-irradiation interval (P < 0.01), keloid site (P < 0.01), surgical method (P = 0.04) and keloid size (P < 0.02). Adverse effects were observed in 9.83% (82/834). No radiation-induced cancers were observed. Hypofractionated high-energy electron beam radiotherapy for keloids yielded excellent outcomes, especially in cases without skin grafting. Early postoperative radiotherapy with limited hypofractionation could be a good choice for keloid treatment. (author)

  13. Dynamics of Interocular Suppression in Amblyopic Children during Electronically Monitored Occlusion Therapy: First Insight.

    Science.gov (United States)

    Kehrein, Stephan; Kohnen, Thomas; Fronius, Maria

    2016-06-01

    Interocular suppression is assumed to be the mechanism leading to impaired visual acuity, especially in strabismic amblyopia. Little is known about the dynamics of suppression during treatment. The aim of our study was to assess the development of the depth of suppression and its relation to changes in visual acuity during electronically monitored occlusion treatment. In a prospective pilot study, 15 amblyopes (8 with and 7 without strabismus) aged 5 to 16 years (mean 10.24 years) were examined before initiation of patching and then every 3 to 6 weeks for 4 months. To quantify suppression, a red filter ladder (Sbisa bar) was used, attenuating the image of the dominant eye until the patients reported a binocular perception (diplopia, rivalry, color mixture) or a change in eye dominance. Acuity was assessed with crowded Landolt rings. Daily occlusion was recorded using occlusion dose monitors. The depth of interocular suppression showed a biphasic change: it increased significantly during the first month (P=0.02), while visual acuity improved (mean 0.14 log units ±0.13; Pocclusion and suppression changes was not statistically significant. This first insight into the functional changes during electronically monitored patching suggests a complex relationship between visual acuity and interocular suppression that seems to be influenced by the presence of strabismus. Knowledge of the dynamics of interocular suppression is crucial for enhancing the outcome of occlusion treatment and also for the evaluation of its future role compared to emerging dichoptic treatments.

  14. A basic study of intraoperative radiation on the stomach

    International Nuclear Information System (INIS)

    Aoki, Tetsuya

    1978-01-01

    In a basic study of intraoperative radiation on the stomach, adult dogs were laparotomized, and radiated on the stomach and gastroduodenal anastomosed part with an electron beam to 1,000 - 4,000 rads to observed its effects on hematologic and histologic findings. 1) No leukopenia occurred with the radiation, but secondary effects such as anemia and hypoproteinemia were noted. 2) On the gastric wall, the mucosa was most severely effected by the radiation, presenting such changes as erosion, atrophy, disappearance of glandular tissue, and fibrosis with the lapse of time. 3) The radiation on the stomach to 3,000 rads was followed by ulceration in one month, by the start of repair of the ulceration in three months, and by its healing in eight months. Histologic examination disclosed no evident damages to the blood vessels by the radiation. 4) Delayed healing of the anastomosed part was noted as an effect of the radiation on this part. 5) The findings in this experiment appear to suggest that the single tolerable dose of electron beam radiation on the stomach and the gastroduodenal anastomosed part should be 3,000 rads. (author)

  15. Neutron fluence in a 18 MeV Electron Accelerator for Therapy

    International Nuclear Information System (INIS)

    Paredes G, L.C.

    2001-01-01

    An investigation was made on the theoretical fundamentals for the determination of the neutron fluence in a linear electron accelerator for radiotherapy applications and the limit values of leakage neutron radiation established by guidelines and standards in radiation protection for these type of accelerators. This investigation includes the following parts: a) Exhaustive bibliographical review on the topics mentioned above, in order to combine and to update the necessary basic information to facilitate the understanding of this subject; b) Analysis of the accelerator operation and identification of its main components, specially in the accelerator head; c) Study of different types of targets and its materials for the Bremsstrahlung production which is based on the electron initial energy, the thickness of the target, and its angular distribution and energy, which influences in the neutron generation by means of the photonuclear and electro disintegration reactions; d) Analysis of the neutron yield based on the target type and its thickness, the energy of electrons and photons; e) Analysis of the neutron energy spectra generated in the accelerator head, inside and outside the treatment room; f) Study of the dosimetry fundamentals for neutron and photon mixed fields, the dosimeter selection criteria and standards applied for these applications, specially the Panasonic U D-809 thermoluminescent dosemeter and C R-39 nuclear track dosimeter; g) Theoretical calculation of the neutron yield using a simplified geometric model for the accelerator head with spherical cell, which considers the target, primary collimator, flattener filter, movable collimators and the head shielding as the main components for radiation production. The cases with W and Pb shielding for closed movable collimators and an irradiation field of 20 x 20 cm 2 were analyzed and, h) Experimental evaluation of the leakage neutron radiation from the patient and head planes, observing that the accelerator

  16. Intraoperative probe detecting β{sup −} decays in brain tumour radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Solfaroli Camillocci, E., E-mail: elena.solfaroli@roma1.infn.it [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Bocci, V.; Chiodi, G. [INFN Sezione di Roma, Roma (Italy); Collamati, F. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Donnarumma, R.; Faccini, R.; Mancini Terracciano, C. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ‘E. Fermi’, Roma (Italy); Mattei, I.; Muraro, S. [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Recchia, L. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Russomando, A. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Toppi, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Traini, G. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Morganti, S. [INFN Sezione di Roma, Roma (Italy)

    2017-02-11

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β{sup −} emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β{sup −} emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  17. Safe surgery: how accurate are we at predicting intra-operative blood loss?

    LENUS (Irish Health Repository)

    2012-02-01

    Introduction Preoperative estimation of intra-operative blood loss by both anaesthetist and operating surgeon is a criterion of the World Health Organization\\'s surgical safety checklist. The checklist requires specific preoperative planning when anticipated blood loss is greater than 500 mL. The aim of this study was to assess the accuracy of surgeons and anaesthetists at predicting intra-operative blood loss. Methods A 6-week prospective study of intermediate and major operations in an academic medical centre was performed. An independent observer interviewed surgical and anaesthetic consultants and registrars, preoperatively asking each to predict expected blood loss in millilitre. Intra-operative blood loss was measured and compared with these predictions. Parameters including the use of anticoagulation and anti-platelet therapy as well as intra-operative hypothermia and hypotension were recorded. Results One hundred sixty-eight operations were included in the study, including 142 elective and 26 emergency operations. Blood loss was predicted to within 500 mL of measured blood loss in 89% of cases. Consultant surgeons tended to underestimate blood loss, doing so in 43% of all cases, while consultant anaesthetists were more likely to overestimate (60% of all operations). Twelve patients (7%) had underestimation of blood loss of more than 500 mL by both surgeon and anaesthetist. Thirty per cent (n = 6\\/20) of patients requiring transfusion of a blood product within 24 hours of surgery had blood loss underestimated by more than 500 mL by both surgeon and anaesthetist. There was no significant difference in prediction between patients on anti-platelet or anticoagulation therapy preoperatively and those not on the said therapies. Conclusion Predicted intra-operative blood loss was within 500 mL of measured blood loss in 89% of operations. In 30% of patients who ultimately receive a blood transfusion, both the surgeon and anaesthetist significantly underestimate

  18. The effectiveness and cost-effectiveness of intraoperative imaging in high-grade glioma resection; a comparative review of intraoperative ALA, fluorescein, ultrasound and MRI.

    Science.gov (United States)

    Eljamel, M Sam; Mahboob, Syed Osama

    2016-12-01

    Surgical resection of high-grade gliomas (HGG) is standard therapy because it imparts significant progression free (PFS) and overall survival (OS). However, HGG-tumor margins are indistinguishable from normal brain during surgery. Hence intraoperative technology such as fluorescence (ALA, fluorescein) and intraoperative ultrasound (IoUS) and MRI (IoMRI) has been deployed. This study compares the effectiveness and cost-effectiveness of these technologies. Critical literature review and meta-analyses, using MEDLINE/PubMed service. The list of references in each article was double-checked for any missing references. We included all studies that reported the use of ALA, fluorescein (FLCN), IoUS or IoMRI to guide HGG-surgery. The meta-analyses were conducted according to statistical heterogeneity between studies. If there was no heterogeneity, fixed effects model was used; otherwise, a random effects model was used. Statistical heterogeneity was explored by χ 2 and inconsistency (I 2 ) statistics. To assess cost-effectiveness, we calculated the incremental cost per quality-adjusted life-year (QALY). Gross total resection (GTR) after ALA, FLCN, IoUS and IoMRI was 69.1%, 84.4%, 73.4% and 70% respectively. The differences were not statistically significant. All four techniques led to significant prolongation of PFS and tended to prolong OS. However none of these technologies led to significant prolongation of OS compared to controls. The cost/QALY was $16,218, $3181, $6049 and $32,954 for ALA, FLCN, IoUS and IoMRI respectively. ALA, FLCN, IoUS and IoMRI significantly improve GTR and PFS of HGG. Their incremental cost was below the threshold for cost-effectiveness of HGG-therapy, denoting that each intraoperative technology was cost-effective on its own. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. The Resection Map : A proposal for intraoperative hepatectomy guidance

    NARCIS (Netherlands)

    Lamata, P.; Jalote-Parmar, A.; Lamata, F.; Declerck, J.

    2008-01-01

    Objective - To propose a new concept of an intra-operative 3D visualisation system to support hepatectomies. This system aims at improving the transfer of pre-operative planning into the intra-operative stage, both in laparoscopic and open approaches. Materials and methods - User (surgeon) centred

  20. Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam

    International Nuclear Information System (INIS)

    Lambert, Jamil; Yin Yongbai; McKenzie, David R.; Law, Sue; Suchowerska, Natalka

    2009-01-01

    A Cerenkov signal is generated when energetic charged particles enter the core of an optical fiber. The Cerenkov intensity can be large enough to interfere with signals transmitted through the fiber. We determine the spectrum of the Cerenkov background signal generated in a poly(methyl methacrylate) optical fiber exposed to photon and electron therapeutic beams from a linear accelerator. This spectral measurement is relevant to discrimination of the signal from the background, as in scintillation dosimetry using optical fiber readouts. We find that the spectrum is approximated by the theoretical curve after correction for the wavelength dependent attenuation of the fiber. The spectrum does not depend significantly on the angle between the radiation beam and the axis of the fiber optic but is dependent on the depth in water at which the fiber is exposed to the beam.

  1. Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy

    CERN Document Server

    Mairani, A; Valente, M; Battistoni, G; Botta, F; Pedroli, G; Ferrari, A; Cremonesi, M; Di Dia, A; Ferrari, M; Fasso, A

    2011-01-01

    Purpose: The calculation of patient-specific dose distribution can be achieved by Monte Carlo simulations or by analytical methods. In this study, FLUKA Monte Carlo code has been considered for use in nuclear medicine dosimetry. Up to now, FLUKA has mainly been dedicated to other fields, namely high energy physics, radiation protection, and hadrontherapy. When first employing a Monte Carlo code for nuclear medicine dosimetry, its results concerning electron transport at energies typical of nuclear medicine applications need to be verified. This is commonly achieved by means of calculation of a representative parameter and comparison with reference data. Dose point kernel (DPK), quantifying the energy deposition all around a point isotropic source, is often the one. Methods: FLUKA DPKS have been calculated in both water and compact bone for monoenergetic electrons (10-3 MeV) and for beta emitting isotopes commonly used for therapy ((89)Sr, (90)Y, (131)I, (153)Sm, (177)Lu, (186)Re, and (188)Re). Point isotropic...

  2. SU-F-T-83: Infant Total Skin Electron Therapy Using Five Fields Technique

    International Nuclear Information System (INIS)

    Saleh, H; Howlin, T; Massey, V

    2016-01-01

    Purpose: We were presented with a 9 month old boy with Relapsed Acute Myeloid Leukemia (AML) involving the skin. The plan was to treat the entire skin using 6 MeV electrons with the infant under complete anesthesia. The purpose of this work is to commission the 6 MeV electron beam and to develop a technique that can be used to deliver total skin dose to infants with minimal patient immobilization. Methods: A baby mannequin phantom that mimics the child’s length was used to determine the best technique to treat the infant. The 76 cm long phantom was placed on the floor. The phantom was placed in four unique immobilization devices to simulate four different treatment positions (anterior, posterior, left lateral and right lateral). Radiochromic films were used to determine beam profile in both axial and radial directions, and percent depth dose (PDD). Absolute calibration of the machine output at 214 cm distance was measured using an Exradin A11 parallel-plate ion chamber. A 1.0 cm plexiglass scatter plate was inserted in the collimator. Mosfet dosimeters were used for dose verification for phantom and and patient. Results: At 214 cm source to surface distance (SSD) using gantry angle of + 20o from vertical beam flatness is + 10% in the radial direction over a region of 70 cm and + 4% in the axial direction over 60 cm. A five field arrangement was determined to optimally deliver the desired dose with > 90% uniformity. The fifth field was used to boost the head vertex. Conclusion: It is possible to treat sedated infants with total skin dose using five positions. Four positions were enough to cover the body and the fifth position boosts the vertex of the head. All fractions can be reproduced accurately daily because of the patient’s stable immobilization.

  3. SU-F-T-83: Infant Total Skin Electron Therapy Using Five Fields Technique

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, H; Howlin, T; Massey, V [University of Kansas Hospital, Overland Park, KS (United States)

    2016-06-15

    Purpose: We were presented with a 9 month old boy with Relapsed Acute Myeloid Leukemia (AML) involving the skin. The plan was to treat the entire skin using 6 MeV electrons with the infant under complete anesthesia. The purpose of this work is to commission the 6 MeV electron beam and to develop a technique that can be used to deliver total skin dose to infants with minimal patient immobilization. Methods: A baby mannequin phantom that mimics the child’s length was used to determine the best technique to treat the infant. The 76 cm long phantom was placed on the floor. The phantom was placed in four unique immobilization devices to simulate four different treatment positions (anterior, posterior, left lateral and right lateral). Radiochromic films were used to determine beam profile in both axial and radial directions, and percent depth dose (PDD). Absolute calibration of the machine output at 214 cm distance was measured using an Exradin A11 parallel-plate ion chamber. A 1.0 cm plexiglass scatter plate was inserted in the collimator. Mosfet dosimeters were used for dose verification for phantom and and patient. Results: At 214 cm source to surface distance (SSD) using gantry angle of + 20o from vertical beam flatness is + 10% in the radial direction over a region of 70 cm and + 4% in the axial direction over 60 cm. A five field arrangement was determined to optimally deliver the desired dose with > 90% uniformity. The fifth field was used to boost the head vertex. Conclusion: It is possible to treat sedated infants with total skin dose using five positions. Four positions were enough to cover the body and the fifth position boosts the vertex of the head. All fractions can be reproduced accurately daily because of the patient’s stable immobilization.

  4. Assessing the registration of CT-scan data to intraoperative x rays by fusing x rays and preoperative information

    Science.gov (United States)

    Gueziec, Andre P.

    1999-05-01

    This paper addresses a key issue of providing clinicians with visual feedback to validate a computer-generated registration of pre-operative and intra-operative data. With this feedback information, the clinician may decide to proceed with a computer-assisted intervention, revert to a manual intervention, or potentially provide information to the computer system to improve the registration. The paper focuses on total hip replacement (THR) surgery, but similar techniques could be applied to other types of interventions or therapy, including orthopedics, neurosurgery, and radiation therapy. Pre-operative CT data is used to plane the surgery (select an implant type, size and precise position), and is registered to intra-operative X-ray images, allowing to execute the plan: mill a cavity with the implant's shape. (Intra-operative X-ray images must be calibrated with respect to the surgical device executing the plan). One novel technique presented in this paper consists of simulating a post-operative X-ray image of the tissue of interest before doing the procedure, by projecting the registered implant onto an intra-operative X- ray image (corrected for distortion or not), providing clinicians with familiar and easy to interpret images. As an additional benefit, this method provides new means for comparing various strategies for registering pre-operative data to the physical space of the operating room.

  5. The Heart of the Matter: Increasing Quality and Charge Capture from Intraoperative Transesophageal Echocardiography.

    Science.gov (United States)

    Sanford, Joseph A; Kadry, Bassam; Oakes, Daryl; Macario, Alex; Schmiesing, Cliff

    2016-04-15

    Although transesophageal echocardiography is routinely performed at our institution, there is no easy way to document the procedure in the electronic medical record and generate a bill compliant with reimbursement requirements. We present the results of a quality improvement project that used agile development methodology to incorporate intraoperative transesophageal echocardiography into the electronic medical record. We discuss improvements in the quality of clinical documentation, technical workflow challenges overcome, and cost and time to return on investment. Billing was increased from an average of 36% to 84.6% when compared with the same time period in the previous year. The expected recoupment of investment for this project is just 18 weeks.

  6. Methods and clinical utility of intraoperative radiotherapy (IORT) in breast-conserving surgery

    International Nuclear Information System (INIS)

    Miyauchi, Mitsuru; Yamamoto, Naoto; Fujita, Yoshihiro; Honda, Ichiro; Hatano, Kazuo; Sekiya, Yuichi; Suzuki, Masato; Nakajima, Nobuyuki.

    1996-01-01

    We have developed an intraoperative radiotherapy technique in breast-conserving surgery. Following lumpectomy and axillary dissection up to Level II, the subcutaneous fat layer was lifted from the gland over the entire breast. Electron beams of 25 Gy were irradiated within cylinder, avoiding the skin and subcutaneous tissue. The surface of the gland was covered with cotton swabs saturated with normal saline to equalize the energy depth to the chest wall. This technique has so far been applied to 8 patients, all of whom went through a successful postoperative period without serious complications. The cosmetic results were satisfactory from immediately after the operation. Intraoperative radiotherapy combined with breast-conserving surgery may be helpful in improving the QOL of patients by eliminating the adverse effects associated radiation injury to the skin of the breast and long-term postoperative follow-up. (author)

  7. Energy modulated electron therapy: Design, implementation, and evaluation of a novel method of treatment planning and delivery

    Science.gov (United States)

    Al-Yahya, Khalid

    Energy modulated electron therapy (EMET) is a promising treatment modality that has the fundamental capabilities to enhance the treatment planning and delivery of superficially located targets. Although it offers advantages over x-ray intensity modulated radiation therapy (IMRT), EMET has not been widely implemented to the same level of accuracy, automation, and clinical routine as its x-ray counterpart. This lack of implementation is attributed to the absence of a remotely automated beam shaping system as well as the deficiency in dosimetric accuracy of clinical electron pencil beam algorithms in the presence of beam modifiers and tissue heterogeneities. In this study, we present a novel technique for treatment planning and delivery of EMET. The delivery is achieved using a prototype of an automated "few leaf electron collimator" (FLEC). It consists of four copper leaves driven by stepper motors which are synchronized with the x-ray jaws in order to form a series of collimated rectangular openings or "fieldlets". Based on Monte Carlo studies, the FLEC has been designed to serve as an accessory tool to the current accelerator equipment. The FLEC was constructed and its operation was fully automated and integrated with the accelerator through an in-house assembled control unit. The control unit is a portable computer system accompanied with customized software that delivers EMET plans after acquiring them from the optimization station. EMET plans are produced based on dose volume constraints that employ Monte Carlo pre-generated and patient-specific kernels which are utilized by an in-house developed optimization algorithm. The structure of the optimization software is demonstrated. Using Monte Carlo techniques to calculate dose allows for accurate modeling of the collimation system as well as the patient heterogeneous geometry and take into account their impact on optimization. The Monte Carlo calculations were validated by comparing them against output

  8. Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy.

    Science.gov (United States)

    Di Venanzio, C; Marinelli, Marco; Tonnetti, A; Verona-Rinati, G; Falco, M D; Pimpinella, M; Ciccotelli, A; De Stefano, S; Felici, G; Marangoni, F

    2015-12-01

    To characterize a synthetic diamond dosimeter (PTW Freiburg microDiamond 60019) in high dose-per-pulse electron beams produced by an Intra Operative Radiation Therapy (IORT) dedicated accelerator. The dosimetric properties of the microDiamond were assessed under 6, 8 and 9 MeV electron beams by a NOVAC11 mobile accelerator (Sordina IORT Technologies S.p.A.). The characterization was carried out with dose-per-pulse ranging from 26 to 105 mGy per pulse. The microDiamond performance was compared with an Advanced Markus ionization chamber and a PTW silicon diode E in terms of dose linearity, percentage depth dose (PDD) curves, beam profiles and output factors. A good linearity of the microDiamond response was verified in the dose range from 0.2 Gy to 28 Gy. A sensitivity of 1.29 nC/Gy was measured under IORT electron beams, resulting within 1% with respect to the one obtained in reference condition under (60)Co gamma irradiation. PDD measurements were found in agreement with the ones by the reference dosimeters, with differences in R50 values below 0.3 mm. Profile measurements evidenced a high spatial resolution of the microDiamond, slightly worse than the one of the silicon diode. The penumbra widths measured by the microDiamond resulted approximately 0.5 mm larger than the ones by the Silicon diode. Output factors measured by the microDiamond were found within 2% with those obtained by the Advanced Markus down to 3 cm diameter field sizes. The microDiamond dosimeter was demonstrated to be suitable for precise dosimetry in IORT applications under high dose-per-pulse conditions. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Total skin electron beam therapy for cutaneous T-cell lymphoma: A nationwide cohort study from Denmark

    International Nuclear Information System (INIS)

    Lindahl, Lise M.; Iversen, Lars; Kamstrup, Maria R.; Gniadecki, Robert; Petersen, Peter M.; Specht, Lena; Wiren, Johan; Fenger-Groen, Morten

    2011-01-01

    Background. Total skin electron beam therapy (TSEBT) is an effective palliative treatment for cutaneous T-cell lymphoma (CTCL). In the present study we reviewed the clinical response to TSEBT in Danish patients with CTCL. Material and methods. This retrospective study included 35 patients with CTCL treated with TSEBT in Denmark from 2001 to 2008 and followed for a median time of 7.6 months (range 3 days-3.7 years). Twenty five patients were treated with high-dose (30 Gy) and 10 patients in a protocol with low-dose (4 Gy) TSEBT. Results. Patients treated with low-dose therapy had inadequate response to treatment compared to patients treated with high-dose. Consequently the study with low-dose was discontinued and published. In patients treated with high-dose the overall response rate was 100%. Complete response (CR) rate was 68% and CR occurred after a median time of 2.1 months (range 1.8 months - 2.0 years). We found no difference in CR rate in patients with T2 (66.7%) and T3 disease (78.6%) (p = 0.64). Following CR 82.4% relapsed at a median time of four months (range 12 days-11.5 months). Relapse-free-survival was similar in patients with T2 and T3 disease (p 0.77). Progressive disease (PD) was experienced in 28.0% and the median time to PD was 9.0 months (range 4.6-44.3 months). Overall progression-free survival was 95.3%, 72.1% and 64.1% after 0.5-, 1- and 2-years. Effects of initial therapy on TSEBT treatment response and side effects to TSEBT were also analyzed. Conclusion. In conclusion, the present study confirms that high-dose TSEBT is an effective, but generally not a curative therapy in the management of CTCL. High-dose treatment yielded significantly better results than low-dose treatment with 4 Gy. TSEBT offers significant palliation in most patients when other skin-directed or systemic treatments have failed

  10. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  11. Erratum: Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy.

    Science.gov (United States)

    Sarmento, Sandra; Costa, Filipa; Pereira, Alexandre; Lencart, Joana; Dias, Anabela; Cunha, Luís; Sousa, Olga; Silva, José Pedro; Santos, Lúcio

    2015-12-15

    After publication of this study [1], the authors noticed that the funding was incorrectly acknowledged. The correct Acknowledgements section can be found below: “This work was partly funded by Fundação para a Ciência e Tecnologia (FCT), in the framework of the project PTDC/SAU-ENB/117631/2010, which is cofinanced by FEDER, through Programa Operacional Fatores de Competitividade - COMPETE of QREN (reference FCOMP-01-0124-FEDER-021141).”

  12. Relationship Between Chromatin Structure and Sensitivity to Molecularly Targeted Auger Electron Radiation Therapy

    International Nuclear Information System (INIS)

    Terry, Samantha Y.A.; Vallis, Katherine A.

    2012-01-01

    Purpose: The open structure of euchromatin renders it susceptible to DNA damage by ionizing radiation (IR) compared with compact heterochromatin. The effect of chromatin configuration on the efficacy of Auger electron radiotherapy was investigated. Methods and Materials: Chromatin structure was altered in MDA-MB-468 and 231-H2N human breast cancer cells by suberoylanilide hydroxamic acid (SAHA), 5-aza-2-deoxycytidine, or hypertonic treatment. The extent and duration of chromatin structural changes were evaluated using the micrococcal nuclease assay. DNA damage (γH2AX assay) and clonogenic survival were evaluated after exposure to 111 In-DTPA-hEGF, an Auger electron-emitting radiopharmaceutical, or IR. The intracellular distribution of 111 In-DTPA-hEGF after chromatin modification was investigated in cell fractionation experiments. Results: Chromatin remained condensed for up to 20 minutes after NaCl and in a relaxed state 24 hours after SAHA treatment. The number of γH2AX foci per cell was greater in MDA-MB-468 and 231-H2N cells after IR (0.5 Gy) plus SAHA (1 μM) compared with IR alone (16 ± 0.6 and 14 ± 0.3 vs. 12 ± 0.4 and 11 ± 0.2, respectively). More γH2AX foci were observed in MDA-MB-468 and 231-H2N cells exposed to 111 In-DTPA-hEGF (6 MBq/μg) plus SAHA vs. 111 In-DTPA-hEGF alone (11 ± 0.3 and 12 ± 0.7 vs. 9 ± 0.4 and 7 ± 0.3, respectively). 5-aza-2-deoxycytidine enhanced the DNA damage caused by IR and 111 In-DTPA-hEGF. Clonogenic survival was reduced in MDA-MB-468 and 231-H2N cells after IR (6 Gy) plus SAHA (1 μM) vs. IR alone (0.6% ± 0.01 and 0.3% ± 0.2 vs. 5.8% ± 0.2 and 2% ± 0.1, respectively) and after 111 In-DTPA-hEGF plus SAHA compared to 111 In-DTPA-hEGF alone (21% ± 0.4% and 19% ± 4.6 vs. 33% ± 2.3 and 32% ± 3.7). SAHA did not affect 111 In-DTPA-hEGF nuclear localization. Hypertonic treatment resulted in fewer γH2AX foci per cell after IR and 111 In-DTPA-hEGF compared to controls but did not significantly alter clonogenic

  13. Photo-excitation of electrons in cytochrome c oxidase as a theory of the mechanism of the increase of ATP production in mitochondria by laser therapy

    Science.gov (United States)

    Zielke, Andrzej

    2014-02-01

    The hypothesis explains the molecular basis for restoring mitochondrial function by laser therapy. It also explains how laser therapy reverses both excessive oxidation (lack of NADH/FADH2) and excessive reduction (lack of O2) states of cytochrome c oxidase complex. It is proposed that photons interact with heme molecules of cytochrome c oxidase. A molecule of heme contains a porphyrin ring and an atom of iron in the center. The iron atom (Fe) can switch oxidation states back and forth between ferrous (Fe2+) and ferric (Fe3+) by accepting or releasing an electron. The porphyrin ring is a complex aromatic molecule that has 26 pi electrons which are "delocalized", spinning in the carbon rings creating a resonating electromagnetic cloud. Photons with similar wavelengths are absorbed by the cloud increasing its energy. The energy is then passed on to the centrally located atom of iron existing in a reduced state (Fe2+). The electrons on the orbits of the iron atom accept this electromagnetic energy, and change orbitals to a higher energetic level. If the energy is sufficient, electrons leave the atom entirely. If this occurs, Fe2+ become oxidized to Fe3+ releasing electrons, thus restoring electron flow and the production of ATP. At the same time, electrons freed from complex IV may have sufficient energy to be picked by NAD+/FADH and re-enter the chain at the complex I or II amplifying the flow of electrons.

  14. Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy.

    Science.gov (United States)

    Botta, F; Mairani, A; Battistoni, G; Cremonesi, M; Di Dia, A; Fassò, A; Ferrari, A; Ferrari, M; Paganelli, G; Pedroli, G; Valente, M

    2011-07-01

    The calculation of patient-specific dose distribution can be achieved by Monte Carlo simulations or by analytical methods. In this study, FLUKA Monte Carlo code has been considered for use in nuclear medicine dosimetry. Up to now, FLUKA has mainly been dedicated to other fields, namely high energy physics, radiation protection, and hadrontherapy. When first employing a Monte Carlo code for nuclear medicine dosimetry, its results concerning electron transport at energies typical of nuclear medicine applications need to be verified. This is commonly achieved by means of calculation of a representative parameter and comparison with reference data. Dose point kernel (DPK), quantifying the energy deposition all around a point isotropic source, is often the one. FLUKA DPKS have been calculated in both water and compact bone for monoenergetic electrons (10-3 MeV) and for beta emitting isotopes commonly used for therapy (89Sr, 90Y, 131I 153Sm, 177Lu, 186Re, and 188Re). Point isotropic sources have been simulated at the center of a water (bone) sphere, and deposed energy has been tallied in concentric shells. FLUKA outcomes have been compared to PENELOPE v.2008 results, calculated in this study as well. Moreover, in case of monoenergetic electrons in water, comparison with the data from the literature (ETRAN, GEANT4, MCNPX) has been done. Maximum percentage differences within 0.8.RCSDA and 0.9.RCSDA for monoenergetic electrons (RCSDA being the continuous slowing down approximation range) and within 0.8.X90 and 0.9.X90 for isotopes (X90 being the radius of the sphere in which 90% of the emitted energy is absorbed) have been computed, together with the average percentage difference within 0.9.RCSDA and 0.9.X90 for electrons and isotopes, respectively. Concerning monoenergetic electrons, within 0.8.RCSDA (where 90%-97% of the particle energy is deposed), FLUKA and PENELOPE agree mostly within 7%, except for 10 and 20 keV electrons (12% in water, 8.3% in bone). The

  15. Intraoperative photodynamic treatment for high-grade gliomas

    Science.gov (United States)

    Dupont, C.; Reyns, N.; Deleporte, P.; Mordon, S.; Vermandel, M.

    2017-02-01

    Glioblastoma (GBM) is the most common primary brain tumor. Its incidence is estimated at 5 to 7 new cases each year for 100 000 inhabitants. Despite reference treatment, including surgery, radiation oncology and chemotherapy, GBM still has a very poor prognosis (median survival of 15 months). Because of a systematic relapse of the tumor, the main challenge is to improve local control. In this context, PhotoDynamic Therapy (PDT) may offer a new treatment modality. GBM recurrence mainly occurs inside the surgical cavity borders. Thus, a new light applicator was designed for delivering light during a PDT procedure on surgical cavity borders after Fluorescence Guided Resection. This device combines an inflatable balloon and a light source. Several experimentations (temperature and impermeability tests, homogeneity of the light distribution and ex-vivo studies) were conducted to characterize the device. An abacus was created to determine illumination time from the balloon volume in order to reach a therapeutic fluence value inside the borders of the surgical cavity. According to our experience, cavity volumes usually observed in the neurosurgery department lead to an acceptable average lighting duration, from 20 to 40 minutes. Thus, extra-time needed for PDT remains suitable with anesthesia constraints. A pilot clinical trial is planned to start in 2017 in our institution. In view of the encouraging results observed in preclinical or clinical, this intraoperative PDT treatment can be easily included in the current standard of care.

  16. An appraisal of intraoperative radiotherapy for pancreas cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gotoh, Mitsukazu; Monden, Morito; Sakon, Masato; Kanai, Toshio; Umeshita, Koji; Ikeda, Hiroshi; Mori, Takesada (Osaka Univ. (Japan). Faculty of Medicine)

    1993-03-01

    Intraoperative radiotherapy (IORT) which was originally used for unresectable cancer has been applied to the cases after pancreas resection. However, it has not been clarified which stages of patients will have the beneficial effect of IORT on their prognosis. In this study, IORT after pancreas resection was appraised on the basis of the patient prognosis. Seventy-two pancreatectomized patients including 6 patients of Stage I, 18 of Stage II, 25 of Stage III and 23 of Stage IV, which was determined by the general rules for cancer of the pancreas in Japan Pancreas Society were employed in this study. Four Stage III and 15 Stage IV patients were treated with IORT (25-30 Gy) after pancreatectomy. Ten of these patients underwent postoperative external beam radiotherapy (22-48 Gy). All but one Stage I patient were currently alive. The median survival time (MST) of Stage II were 908 days and 2 were alive over 5 years after operation. MST of Stage III without IORT was 310 pod and all died within 906 pod. In contrast, all four Stage III patients were currently alive without a sign of recurrence (3, 10, 15, 57 pom). All Stage IV patients died within 462 pod, while three patients treated with IORT were alive over this period. These data suggest IORT improves the prognosis of Stage III patients when combined with radical resection of the pancreas. But it is not the case with the more advanced cases, where systemic anticancer adjuvant therapy might be indicated. (author).

  17. Intraoperative radiotherapy in pancreatic cancer: A systematic review

    International Nuclear Information System (INIS)

    Ruano-Ravina, Alberto; Almazan Ortega, Raquel; Guedea, Ferrran

    2008-01-01

    Background and purpose: Intraoperative radiotherapy (IORT) has been considered for treatment of pancreas cancer since local recurrence rates are very high. This study assesses the efficacy and safety of IORT in pancreatic cancer. Materials and methods: We conducted a systematic review of scientific literature from January 1995 to February 2007, including Medline, Embase, ISI Web of Science and HTA (Health Technology Assessment). By applying a series of inclusion criteria, two independent reviewers selected those studies in which a minimum of 30 patients received IORT and which furnished survival results based on a minimum 3-month follow-up. Results: Fourteen papers were included, one was an IORT assessment report, 5 were cohort studies, and the remaining 8 were case series studies, 2 of which belonged to the same series. In general, these studies showed that IORT could slightly increase survival among patients with pancreatic cancer in localized stages. However, the results were not conclusively in favor of IORT in the case of pancreatic cancer in locally advanced and metastatic stages. There were no published studies that assessed quality of life. Conclusions: There is no clear evidence to indicate that IORT is more effective than other therapies in treating pancreatic cancer in locally advanced and metastatic stages

  18. Medical setup of intraoperative BNCT at JRR-4

    International Nuclear Information System (INIS)

    Akutsu, H.; Yamamoto, T.; Matsumura, A.

    2000-01-01

    Since October 1999, we have been performing clinical trials of intraoperative boron neutron capture therapy (IOBNCT) using a mixed thermal-epithermal beam at the Japan Research Reactor No. 4 (JRR-4). For immediate pre-BNCT care, including administration of a boron compound as well as post-BNCT care, a collaborating neurosurgical department of the University of Tsukuba was prepared in the vicinity of JRR-4. Following craniotomy in the treatment room, anesthetized patients were transported into the irradiation room for BNCT. The boron concentration in tissue was measured by the PGA and ICP-AES methods. The long-term follow-up was done at the University of Tsukuba Hospital. IOBNCT is a complex clinical procedure, which requires sophisticated operating team and co-medical staffs and also cooperation with physicist team. IOBNCT is a complex clinical procedure requiring a high level of cooperation among the operating team, co-medical staff, and physicists. For the safe and successful performance of IOBNCT, we have made the program including critical pathway and prepared various equipments for IOBNCT. To ensure the safe and successful performance of IOBNCT, we developed a critical pathway for use during the procedure, and prepared various apparatus for IOBNCT. (author)

  19. Mammographic Findings after Intraoperative Radiotherapy of the Breast

    International Nuclear Information System (INIS)

    Rivera, R.; Holmes, D.R.; Smith-Bronstein, V.S.; Villegas-Mendez, S.; Rayhanabad, J.; Sheth, P.; Rashtian, A.

    2012-01-01

    Intraoperative Radiotherapy (IORT) is a form of accelerated partial breast radiation that has been shown to be equivalent to conventional whole breast external beam radiotherapy (EBRT) in terms of local cancer control. However, questions have been raised about the potential of f IORT to produce breast parenchymal changes that could interfere with mammographic surveillance of cancer recurrence. The purpose of this study was to identify, quantify, and compare the mammographic findings of patients who received IORT and EBRT in a prospective, randomized controlled clinical trial of women with early stage invasive breast cancer undergoing breast conserving therapy between July 2005 and December 2009. Treatment groups were compared with regard to the 1, 2 and 4-year incidence of 6 post-operative mammographic findings: architectural distortion, skin thickening, skin retraction, calcifications, fat necrosis, and mass density. Blinded review of 90 sets of mammograms of 15 IORT and 16 EBRT patients demonstrated a higher incidence of fat necrosis among IORT recipients at years 1, 2, and 4. However, none of the subjects were judged to have suspicious mammogram findings and fat necrosis did not interfere with mammographic interpretation.

  20. An appraisal of intraoperative radiotherapy for pancreas cancer

    International Nuclear Information System (INIS)

    Gotoh, Mitsukazu; Monden, Morito; Sakon, Masato; Kanai, Toshio; Umeshita, Koji; Ikeda, Hiroshi; Mori, Takesada

    1993-01-01

    Intraoperative radiotherapy (IORT) which was originally used for unresectable cancer has been applied to the cases after pancreas resection. However, it has not been clarified which stages of patients will have the beneficial effect of IORT on their prognosis. In this study, IORT after pancreas resection was appraised on the basis of the patient prognosis. Seventy-two pancreatectomized patients including 6 patients of Stage I, 18 of Stage II, 25 of Stage III and 23 of Stage IV, which was determined by the general rules for cancer of the pancreas in Japan Pancreas Society were employed in this study. Four Stage III and 15 Stage IV patients were treated with IORT (25-30 Gy) after pancreatectomy. Ten of these patients underwent postoperative external beam radiotherapy (22-48 Gy). All but one Stage I patient were currently alive. The median survival time (MST) of Stage II were 908 days and 2 were alive over 5 years after operation. MST of Stage III without IORT was 310 pod and all died within 906 pod. In contrast, all four Stage III patients were currently alive without a sign of recurrence (3, 10, 15, 57 pom). All Stage IV patients died within 462 pod, while three patients treated with IORT were alive over this period. These data suggest IORT improves the prognosis of Stage III patients when combined with radical resection of the pancreas. But it is not the case with the more advanced cases, where systemic anticancer adjuvant therapy might be indicated. (author)

  1. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy.

    Science.gov (United States)

    Cao, Yun; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia

    2014-02-01

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C(5+) ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C(5+) ion beam was got when work gas was CH4 while about 262 eμA of C(5+) ion beam was obtained when work gas was C2H2 gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  2. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yun, E-mail: caoyun@impcas.ac.cn; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia [Institute of Modern Physics, CAS, Lanzhou 730000 (China)

    2014-02-15

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C{sup 5+} ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C{sup 5+} ion beam was got when work gas was CH{sub 4} while about 262 eμA of C{sup 5+} ion beam was obtained when work gas was C{sub 2}H{sub 2} gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  3. Verification of setup errors in external beam radiation therapy using electronic portal imaging

    International Nuclear Information System (INIS)

    Krishna Murthy, K.; Al-Rahbi, Zakiya; Sivakumar, S.S.; Davis, C.A.; Ravichandran, R.

    2008-01-01

    The objective of this study was to conduct an audit on QA aspects of treatment delivery by the verification of the treatment fields position on different days to document the efficiency of immobilization methods and reproducibility of treatment. A retrospective study was carried out on 60 patients, each 20 treated for head and neck, breast, and pelvic sites; and a total of 506 images obtained by electronic portal imaging device (EPID) were analyzed. The portal images acquired using the EPID systems attached to the Varian linear accelerators were superimposed on the reference images. The anatomy matching software (Varian portal Vision. 6.0) was used, and the displacements in two dimensions and rotation were noted for each treated field to study the patient setup errors. The percentages of mean deviations more than 3 mm in lateral (X) and longitudinal (Y) directions were 17.5%, 11.25%, and 7.5% for breast, pelvis, and head and neck cases respectively. In all cases, the percentage of mean deviation with more than 5 mm error was 0.83%. The maximum average mean deviation in all the cases was 1.87. The average mean SD along X and Y directions in all the cases was less than 2.65. The results revealed that the ranges of setup errors are site specific and immobilization methods improve reproducibility. The observed variations were well within the limits. The study confirmed the accuracy and quality of treatments delivered to the patients. (author)

  4. Intraoperative nerve monitoring in laryngotracheal surgery.

    Science.gov (United States)

    Bolufer, Sergio; Coves, María Dolores; Gálvez, Carlos; Villalona, Gustavo Adolfo

    Laryngotracheal surgery has an inherent risk of injury to the recurrent laryngeal nerves (RLN). These complications go from minor dysphonia to even bilateral vocal cord paralysis. The intraoperative neuromonitoring of the RLN was developed in the field of thyroid surgery, in order to preserve nerve and vocal cord function. However, tracheal surgery requires in-field intubation of the distal trachea, which limits the use of nerve monitoring using conventional endotracheal tube with surface electrodes. Given these challenges, we present an alternative method for nerve monitoring during laryngotracheal surgery through the insertion of electrodes within the endolaryngeal musculature by bilateral puncture. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Intraoperative radiotherapy for locally advanced refractory cancer

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Mitsuyuki; Takahashi, Masaji; Ono, Koji; Dodo, Yoshihiro; Hiraoka, Masahiro [Kyoto Univ. (Japan). Faculty of Medicine

    1983-05-01

    Clinical results of intraoperative radiotherapy (IOR) in carcinoma of the stomach and prostate, and malignant soft tissue tumors are reported. The 5-year survival rate was found to be increased by IOR in stages II-IV gastric cancer. From the analysis of the clinical results of prostatic cancer, a single dose of 3,500 rad was considered to be a potential curative dose for the tumor less than 3 cm in diameter. The local recurrence rate of patients with malignant soft tissue tumors who received a single dose ranging from 3,000 to 4,500 rad was 5.9 and the 5-year survival rate was 64.6 %.

  6. Brain mapping in tumors: intraoperative or extraoperative?

    Science.gov (United States)

    Duffau, Hugues

    2013-12-01

    In nontumoral epilepsy surgery, the main goal for all preoperative investigation is to first determine the epileptogenic zone, and then to analyze its relation to eloquent cortex, in order to control seizures while avoiding adverse postoperative neurologic outcome. To this end, in addition to neuropsychological assessment, functional neuroimaging and scalp electroencephalography, extraoperative recording, and electrical mapping, especially using subdural strip- or grid-electrodes, has been reported extensively. Nonetheless, in tumoral epilepsy surgery, the rationale is different. Indeed, the first aim is rather to maximize the extent of tumor resection while minimizing postsurgical morbidity, in order to increase the median survival as well as to preserve quality of life. As a consequence, as frequently seen in infiltrating tumors such as gliomas, where these lesions not only grow but also migrate along white matter tracts, the resection should be performed according to functional boundaries both at cortical and subcortical levels. With this in mind, extraoperative mapping by strips/grids is often not sufficient in tumoral surgery, since in essence, it allows study of the cortex but cannot map subcortical pathways. Therefore, intraoperative electrostimulation mapping, especially in awake patients, is more appropriate in tumor surgery, because this technique allows real-time detection of areas crucial for cerebral functions--eloquent cortex and fibers--throughout the resection. In summary, rather than choosing one or the other of different mapping techniques, methodology should be adapted to each pathology, that is, extraoperative mapping in nontumoral epilepsy surgery and intraoperative mapping in tumoral surgery. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.

  7. Best practices to optimize intraoperative photography.

    Science.gov (United States)

    Gaujoux, Sébastien; Ceribelli, Cecilia; Goudard, Geoffrey; Khayat, Antoine; Leconte, Mahaut; Massault, Pierre-Philippe; Balagué, Julie; Dousset, Bertrand

    2016-04-01

    Intraoperative photography is used extensively for communication, research, or teaching. The objective of the present work was to define, using a standardized methodology and literature review, the best technical conditions for intraoperative photography. Using either a smartphone camera, a bridge camera, or a single-lens reflex (SLR) camera, photographs were taken under various standard conditions by a professional photographer. All images were independently assessed blinded to technical conditions to define the best shooting conditions and methods. For better photographs, an SLR camera with manual settings should be used. Photographs should be centered and taken vertically and orthogonal to the surgical field with a linear scale to avoid error in perspective. The shooting distance should be about 75 cm using an 80-100-mm focal lens. Flash should be avoided and scialytic low-powered light should be used without focus. The operative field should be clean, wet surfaces should be avoided, and metal instruments should be hidden to avoid reflections. For SLR camera, International Organization for Standardization speed should be as low as possible, autofocus area selection mode should be on single point AF, shutter speed should be above 1/100 second, and aperture should be as narrow as possible, above f/8. For smartphone, use high dynamic range setting if available, use of flash, digital filter, effect apps, and digital zoom is not recommended. If a few basic technical rules are known and applied, high-quality photographs can be taken by amateur photographers and fit the standards accepted in clinical practice, academic communication, and publications. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy.

    Science.gov (United States)

    Carver, Robert L; Hogstrom, Kenneth R; Chu, Connel; Fields, Robert S; Sprunger, Conrad P

    2013-07-01

    The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer. PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal(®) (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle(3) (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point. The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average ± 1σ dose difference (calculated - measured) of -0.65% ± 1.62% without the bolus and -0.20% ± 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19% ± 3.27% without the bolus and -0.05% ± 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50% ± 3.06% without bolus and -0.18% ± 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%

  9. Intraoperative tight glucose control using hyperinsulinemic normoglycemia increases delirium after cardiac surgery.

    Science.gov (United States)

    Saager, Leif; Duncan, Andra E; Yared, Jean-Pierre; Hesler, Brian D; You, Jing; Deogaonkar, Anupa; Sessler, Daniel I; Kurz, Andrea

    2015-06-01

    Postoperative delirium is common in patients recovering from cardiac surgery. Tight glucose control has been shown to reduce mortality and morbidity. Therefore, the authors sought to determine the effect of tight intraoperative glucose control using a hyperinsulinemic-normoglycemic clamp approach on postoperative delirium in patients undergoing cardiac surgery. The authors enrolled 198 adult patients having cardiac surgery in this randomized, double-blind, single-center trial. Patients were randomly assigned to either tight intraoperative glucose control with a hyperinsulinemic-normoglycemic clamp (target blood glucose, 80 to 110 mg/dl) or standard therapy (conventional insulin administration with blood glucose target, battery. The authors considered patients to have experienced postoperative delirium when Confusion Assessment Method testing was positive at any assessment. A positive Confusion Assessment Method was defined by the presence of features 1 (acute onset and fluctuating course) and 2 (inattention) and either 3 (disorganized thinking) or 4 (altered consciousness). Patients randomized to tight glucose control were more likely to be diagnosed as being delirious than those assigned to routine glucose control (26 of 93 vs. 15 of 105; relative risk, 1.89; 95% CI, 1.06 to 3.37; P = 0.03), after adjusting for preoperative usage of calcium channel blocker and American Society of Anesthesiologist physical status. Delirium severity, among patients with delirium, was comparable with each glucose management strategy. Intraoperative hyperinsulinemic-normoglycemia augments the risk of delirium after cardiac surgery, but not its severity.

  10. Electronic medical record systems are associated with appropriate placement of HIV patients on antiretroviral therapy in rural health facilities in Kenya: a retrospective pre-post study

    NARCIS (Netherlands)

    Oluoch, Tom; Katana, Abraham; Ssempijja, Victor; Kwaro, Daniel; Langat, Patrick; Kimanga, Davies; Okeyo, Nicky; Abu-Hanna, Ameen; de Keizer, Nicolette

    2014-01-01

    There is little evidence that electronic medical record (EMR) use is associated with better compliance with clinical guidelines on initiation of antiretroviral therapy (ART) among ART-eligible HIV patients. We assessed the effect of transitioning from paper-based to an EMR-based system on

  11. Electronic medication monitoring-informed counseling to improve adherence to combination anti-retroviral therapy and virologic treatment outcomes: a meta-analysis

    NARCIS (Netherlands)

    Langebeek, Nienke; Nieuwkerk, Pythia

    2015-01-01

    Adherence to combination anti-retroviral therapy for HIV infection is a primary determinant of treatment success, but is often suboptimal. Previous studies have suggested that electronic medication monitoring-informed counseling is among the most effective adherence intervention components. Our

  12. Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Azcona, Juan Diego; Li, Ruijiang; Mok, Edward; Hancock, Steven; Xing, Lei

    2013-01-01

    Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators

  13. Preliminary comp arison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity

    International Nuclear Information System (INIS)

    Blasi, Olivier; Fontenot, Jonas D; Fields, Robert S; Gibbons, John P; Hogstrom, Kenneth R

    2011-01-01

    To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume. Helical tomotherapy plans showed dose conformity and homogeneity in the target volume that was equal to or better than the mixed beam plans. Electron-only plans tended to show the lowest doses to normal tissues, but with markedly worse dose conformity and homogeneity than in the other plans. However, adding a 20% IMRT dose fraction (i.e., IMRT:electron weighting = 1:4) to the electron plan restored target conformity and homogeneity to values comparable to helical tomotherapy plans, while maintaining lower normal tissue dose. Mixed beam treatments offer some dosimetric advantages over IMRT or helical tomotherapy for target depths that do not exceed the useful range of the electron beam. Adding a small IMRT component (e.g., IMRT:electron weighting = 1:4) to electron beam plans markedly improved target dose homogeneity and conformity for the cases examined in this study

  14. Long-Term Results of a Highly Performing Conformal Electron Therapy Technique for Chest Wall Irradiation After Mastectomy

    Energy Technology Data Exchange (ETDEWEB)

    Grellier Adedjouma, Noemie, E-mail: grellier.noemie@gmail.com [Department of Radiation Oncology, Institut Curie, Paris (France); Chevrier, Marion [Department of Biostatistics, Institut Curie, Paris (France); Fourquet, Alain; Costa, Emilie; Xu, Haoping [Department of Radiation Oncology, Institut Curie, Paris (France); Berger, Frederique [Department of Biostatistics, Institut Curie, Paris (France); Campana, Francois [Department of Radiation Oncology, Institut Curie, Paris (France); Laki, Fatima [Department of Surgical Oncology, Institut Curie, Paris (France); Beuzeboc, Philippe [Department of Medical Oncology, Institut Curie, Paris (France); Lefeuvre, Delphine [Department of Biostatistics, Institut Curie, Paris (France); Fournier-Bidoz, Nathalie; Kirova, Youlia M. [Department of Radiation Oncology, Institut Curie, Paris (France)

    2017-05-01

    Purpose: To evaluate locoregional control and survival after mastectomy, as well as toxicity, in patients irradiated by a previously described postmastectomy highly conformal electron beam radiation therapy technique (PMERT). Methods and Materials: We included all women irradiated by postmastectomy electron beam radiation therapy for nonmetastatic breast cancer between 2007 and 2011 in our department. Acute and late toxicities were retrospectively assessed using Common Terminology Criteria for Adverse Events version 3.0 criteria. Results: Among the 796 women included, 10.1% were triple-negative, 18.8% HER2-positive, and 24.6% received neoadjuvant chemotherapy (CT). Multifocal lesions were observed in 51.3% of women, and 64.6% had at least 1 involved lymph node (LN). Internal mammary chain, supraclavicular, infraclavicular, and axillary LNs were treated in 85.6%, 88.3%, 77.9%, and 14.9% of cases, respectively. With a median follow-up of 64 months (range, 6-102 months), 5-year locoregional recurrence–free survival and overall survival were 90% (95% confidence interval 88.1%-92.4%) and 90.9% (95% confidence interval 88.9%-93%), respectively. Early skin toxicity was scored as grade 1 in 58.5% of patients, grade 2 in 35.9%, and grade 3 in 4.5%. Concomitant CT was associated with increased grade 3 toxicity (P<.001). At long-term follow-up, 29.8% of patients presented temporary or permanent hyperpigmentation or telangiectasia or fibrosis (grade 1: 23.6%; grade 2: 5.2%; grade 3: 1%), with higher rates among smokers (P=.06); 274 patients (34.4%) underwent breast reconstruction. Only 24 patients (3%) had early esophagitis of grade 1. Only 3 patients developed ischemic heart disease: all had been treated by anthracycline-based CT with or without trastuzumab, all had been irradiated to the left chest wall and LN, and all presented numerous cardiovascular risk factors (2-4 factors). Conclusions: This study demonstrated the good efficacy of this technique in terms of

  15. Intraoperative irradiation for locally recurrent colorectal cancer in previously irradiated patients

    International Nuclear Information System (INIS)

    Haddock, Michael G.; Gunderson, Leonard L.; Nelson, Heidi; Cha, Stephen S.; Devine, Richard M.; Dozois, Roger R.; Wolff, Bruce G.

    2001-01-01

    Purpose: Information in the literature regarding salvage treatment for patients with locally recurrent colorectal cancer who have previously been treated with high or moderate dose external beam irradiation (EBRT) is scarce. A retrospective review was therefore performed in our institution to determine disease control, survival, and tolerance in patients treated aggressively with surgical resection and intraoperative electron irradiation (IOERT) ± additional EBRT and chemotherapy. Methods and Materials: From 1981 through 1994, 51 previously irradiated patients with recurrent locally advanced colorectal cancer without evidence of distant metastatic disease were treated at Mayo Clinic Rochester with surgical resection and IOERT ± additional EBRT. An attempt was made to achieve a gross total resection before IOERT if it could be safely accomplished. The median IOERT dose was 20 Gy (range, 10-30 Gy). Thirty-seven patients received additional EBRT either pre- or postoperatively with doses ranging from 5 to 50.4 Gy (median 25.2 Gy). Twenty patients received 5-fluorouracil ± leucovorin during EBRT. Three patients received additional cycles of 5-fluorouracil ± leucovorin as maintenance chemotherapy. Results: Thirty males and 21 females with a median age of 55 years (range 31-73 years) were treated. Thirty-four patients have died; the median follow-up in surviving patients is 21 months. The median, 2-yr, and 5-yr actuarial overall survivals are 23 months, 48% and 12%, respectively. The 2-yr actuarial central control (within IOERT field) is 72%. Local control at 2 years has been maintained in 60% of patients. There is a trend toward improved local control in patients who received ≥30 Gy EBRT in addition to IOERT as compared to those who received no EBRT or <30 Gy with 2-yr local control rates of 81% vs. 54%. Distant metastatic disease has developed in 25 patients, and the actuarial rate of distant progression at 2 and 4 years is 56% and 76%, respectively. Peripheral

  16. The value of intraoperative sonography in low grade glioma surgery.

    Science.gov (United States)

    Petridis, Athanasios K; Anokhin, Maxim; Vavruska, Jan; Mahvash, Mehran; Scholz, Martin

    2015-04-01

    There is a number of different methods to localize a glioma intraoperatively. Neuronavigation, intraoperative MRI, 5-aminolevulinic acid, as well as intraoperative sonography. Every method has its advantages and disadvantages. Low grade gliomas do not show a specific signal with 5-aminolevulinic acid and are difficult to distinguish macroscopically from normal tissue. In the present study we stress out the importance of intraoperative diagnostic ultrasound for localization of low grade gliomas. We retrospectively evaluated the charts and MRIs of 34 patients with low grade gliomas operated in our department from 2011 until December 2014. The efficacy of ultrasound as an intraoperative navigational tool was assessed. In 15 patients ultrasound was used and in 19 not. Only histologically proven low grades gliomas (astrocytomas grade II) were evaluated. In none of the patients where ultrasound (combined with neuronavigation) was used (N=15) to find the tumors, the target was missed, whereas the exclusive use of neuronavigation missed the target in 5 of 19 cases of small subcortical low grade gliomas. Intraoperative ultrasound is an excellent tool in localizing low grade gliomas intraoperatively. It is an inexpensive, real time neuronavigational tool, which overcomes brain shift. Even when identifying the tumors with ultrasound is very reliable, the extend of resection and the decision to remove any residual tumor with the help of ultrasound is at the moment unreliable. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Improvement of field matching in segmented-field electron conformal therapy using a variable-SCD applicator

    Energy Technology Data Exchange (ETDEWEB)

    Richert, John D [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803-4001 (United States); Hogstrom, Kenneth R [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803-4001 (United States); Fields, Robert S [Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809-3482 (United States); II, Kenneth L Matthews [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803-4001 (United States); Boyd, Robert A [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803-4001 (United States)

    2007-05-07

    The purpose of the present study is to demonstrate that the use of an electron applicator with energy-dependent source-to-collimator distances (SCDs) will significantly improve the dose homogeneity for abutted electron fields in segmented-field electron conformal therapy (ECT). Multiple Coulomb scattering theory was used to calculate and study the P{sub 80-20} penumbra width of off-axis dose profiles as a function of air gap and depth. Collimating insert locations with air gaps (collimator-to-isocenter distance) of 5.0, 7.5, 11.5, 17.5 and 19.5 cm were selected to provide equal P{sub 80-20} at a depth of 1.5 cm in water for energies of 6, 9, 12, 16 and 20 MeV, respectively, for a Varian 2100EX radiation therapy accelerator. A 15 x 15 cm{sup 2} applicator was modified accordingly, and collimating inserts used in the variable-SCD applicator for segmented-field ECT were constructed with diverging edges using a computer-controlled hot-wire cutter, which resulted in 0.27 mm accuracy in the abutted edges. The resulting electron beams were commissioned for the pencil-beam algorithm (PBA) on the Pinnacle{sup 3} treatment planning system. Four hypothetical planning target volumes (PTVs) and one patient were planned for segmented-field ECT using the new variable-SCD applicator, and the resulting dose distributions were compared with those calculated for the identical plans using the conventional 95 cm SCD applicator. Also, a method for quality assurance of segmented-field ECT dose plans using the variable-SCD applicator was evaluated by irradiating a polystyrene phantom using the treatment plans for the hypothetical PTVs. Treatment plans for all four of the hypothetical PTVs using the variable-SCD applicator showed significantly improved dose homogeneity in the abutment regions of the segmented-field ECT plans. This resulted in the dose spread (maximum dose-minimum dose), {sigma}, and D{sub 90-10} in the PTV being reduced by an average of 32%, 29% and 32%, respectively

  18. Characterization of an add-on multileaf collimator for electron beam therapy

    International Nuclear Information System (INIS)

    Gauer, T; Sokoll, J; Cremers, F; Schmidt, R; Harmansa, R; Luzzara, M

    2008-01-01

    An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through interchangeable holders. The mechanical implementation of this feature results in a maximum field displacement of less than 0.6 mm at 90 0 and 270 0 gantry angles. Compared to a 10 x 10 cm applicator at 6-14 MeV, the beam penumbra of the eMLC at a 16 cm collimator-to-isocentre distance is 0.8-0.4 cm greater and the depth-dose curves show a larger build-up effect. Due to the loss in energy dependence of the therapeutic range and the much lower dose output at small beam sizes, a minimum beam size of 3 x 3 cm is necessary to avoid suboptimal dose delivery. Dose output and beam symmetry are not affected by collimator scatter when the central axis is blocked. As a consequence of the broader beam penumbra, uniform dose distributions were measured in the junction region of adjacent beams at perpendicular and oblique beam incidence. However, adjacent beams with a high difference in a beam energy of 6 to 14 MeV generate cold and hot spots of approximately 15% in the abutting region. In order to

  19. Characterization of an add-on multileaf collimator for electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gauer, T; Sokoll, J; Cremers, F; Schmidt, R [Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Harmansa, R [3D Line, Schwarzenbruck (Germany); Luzzara, M [3D Line, Milan (Italy)], E-mail: t.gauer@uke.uni-hamburg.de

    2008-02-21

    An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through interchangeable holders. The mechanical implementation of this feature results in a maximum field displacement of less than 0.6 mm at 90{sup 0} and 270{sup 0} gantry angles. Compared to a 10 x 10 cm applicator at 6-14 MeV, the beam penumbra of the eMLC at a 16 cm collimator-to-isocentre distance is 0.8-0.4 cm greater and the depth-dose curves show a larger build-up effect. Due to the loss in energy dependence of the therapeutic range and the much lower dose output at small beam sizes, a minimum beam size of 3 x 3 cm is necessary to avoid suboptimal dose delivery. Dose output and beam symmetry are not affected by collimator scatter when the central axis is blocked. As a consequence of the broader beam penumbra, uniform dose distributions were measured in the junction region of adjacent beams at perpendicular and oblique beam incidence. However, adjacent beams with a high difference in a beam energy of 6 to 14 MeV generate cold and hot spots of approximately 15% in the abutting region. In

  20. Tolerance of canine portal vein anastomosis to intraoperative X-irradiation

    International Nuclear Information System (INIS)

    Ohara, K.; Takeshima, T.

    1987-01-01

    Tolerance of surgical portal vein anatomosis to intraoperative radiation therapy (IORT) was studied in dogs after single doses of zero, 10, 20 and 40 Gy (290 kVp X-rays). Portal venography was performed prior to IORT and before sacrificing. The dogs were sacrificed 3 and 12 months respectively after irradiation. Portal venography revealed no radiation induced anastomotic stenosis. Autopys disclosed macroscopic periportal fibrosis in all dogs, independent of radiation dose and observation periods. Microscopically, the three tunicas of the vein did not show any pathological changes after any dose level. (orig.)

  1. Intraoperative Radiation Using Low-Kilovoltage X-Rays for Early Breast Cancer: A Single Site Trial.

    Science.gov (United States)

    Silverstein, Melvin J; Epstein, Melinda S; Lin, Kevin; Chen, Peter; Khan, Sadia; Snyder, Lincoln; Guerra, Lisa E; De Leon, Cristina; Mackintosh, Ralph; Coleman, Colleen; Lopez, January; Kim, Brian

    2017-10-01

    Two prospective, randomized trials, TARGIT-A and ELIOT, have shown intraoperative radiation therapy (IORT) to be a safe alternative to whole breast radiation therapy following breast-conserving surgery for selected low-risk patients. However, minimal data are available about the clinical effectiveness of this modality of treatment using the Xoft ® Axxent ® Electronic Brachytherapy (eBx ® ) System ® . A total of 201 patients with 204 early-stage breast cancers were enrolled in a prospective X-ray IORT trial from June 2010 to September 2013. All tumors were treated with breast-conserving surgery and IORT. Data were collected at 1 week, 1 month, 6 months, 1 year, and yearly thereafter. With a median follow-up of 50 months, there have been seven ipsilateral breast tumor events (IBTE), no regional or distant recurrences, and no breast cancer-related deaths. One IBTE was within the IORT field, four outside of the IORT field but within the same quadrant as the index cancer, and two were new biologically different cancers in different quadrants. Three events were in patients who deviated from the protocol criteria. Kaplan-Meier analysis projects that 2.9% of patients will recur locally at 4 years. Recurrence rates observed in this trial were comparable to those of the TARGIT-A and ELIOT trials as well as the retrospective TARGIT-R trial. The low complication rates previously reported by our group as well as the low recurrence rates reported in this study support the cautious use and continued study of IORT in selected women with low-risk breast cancer.

  2. Burnout Among Chinese Adult Reconstructive Surgeons: Incidence, Risk Factors, and Relationship With Intraoperative Irritability.

    Science.gov (United States)

    Zheng, Hanlong; Shao, Hongyi; Zhou, Yixin

    2018-04-01

    Burnout is a major concern in human service occupations, mainly characterizing in emotional exhaustion and depersonalization. There is very limited research dealing with burnout in orthopedic surgeons. Exploring burnout prevalence, risk factors, and intraoperative irritability-related incidences is necessary to improve the quality of life for surgeons. The study population consisted of 202 registered adult reconstructive doctors in China. Burnout was measured using a normalized translated version of the Maslach Burnout Inventory-Human Service Survey. Demographics, professional characteristics, and intraoperative irritability-related questions were also collected by electronic questionnaires. Statistical analysis was performed using SPSS 22.0. The overall rate of burnout was 85.1%. Variables significantly associated with high emotional exhaustion scores included poor sleeping time per day (P = .008), more nights on call per week (P = .048), and absence of research (P = .014). For depersonalization, absence of marriage (P burnout, especially in emotional exhaustion. Residents were the population having the least opportunities to lose temper in operation. Burnout is highly prevalent in Chinese adult reconstructive surgeons, and it had some correlations with irritability. Further research is needed to determine more risk factors and reduce intraoperative irritability-related incidences. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Intraoperative ventilation: incidence and risk factors for receiving large tidal volumes during general anesthesia

    Directory of Open Access Journals (Sweden)

    Fernandez-Bustamante Ana

    2011-11-01

    Full Text Available Abstract Background There is a growing concern of the potential injurious role of ventilatory over-distention in patients without lung injury. No formal guidelines exist for intraoperative ventilation settings, but the use of tidal volumes (VT under 10 mL/kg predicted body weight (PBW has been recommended in healthy patients. We explored the incidence and risk factors for receiving large tidal volumes (VT > 10 mL/kg PBW. Methods We performed a cross-sectional analysis of our prospectively collected perioperative electronic database for current intraoperative ventilation practices and risk factors for receiving large tidal volumes (VT > 10 mL/kg PBW. We included all adults undergoing prolonged (≥ 4 h elective abdominal surgery and collected demographic, preoperative (comorbidities, intraoperative (i.e. ventilatory settings, fluid administration and postoperative (outcomes information. We compared patients receiving exhaled tidal volumes > 10 mL/kg PBW with those that received 8-10 or Results Ventilatory settings were non-uniform in the 429 adults included in the analysis. 17.5% of all patients received VT > 10 mL/kg PBW. 34.0% of all obese patients (body mass index, BMI, ≥ 30, 51% of all patients with a height T > 10 mL/kg PBW. Conclusions Ventilation with VT > 10 mL/kg PBW is still common, although poor correlation with PBW suggests it may be unintentional. BMI ≥ 30, female gender and height

  4. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy

    Science.gov (United States)

    Bruza, Petr; Gollub, Sarah L.; Andreozzi, Jacqueline M.; Tendler, Irwin I.; Williams, Benjamin B.; Jarvis, Lesley A.; Gladstone, David J.; Pogue, Brian W.

    2018-05-01

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  5. Comparison of horizontal and vertical noise power spectrum in measurements by using various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [Dept. of Medical Science, Soonchunhyang University, Asan (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Son, Soon Yong [Dept. of Radiological Technology, Wonkwang Health Science University, Iksan (Korea, Republic of); Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, Shingu University, Sungnam (Korea, Republic of)

    2016-06-15

    The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEWPLUS, Elekta iViewGT and Varian ClinacR iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3-5% between horizontal and vertical direction. In the results of Siemens BEAMVIEWPLUS and Varian ClinacR iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

  6. Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Greer, Peter B.; Popescu, Carmen C.

    2003-01-01

    Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s-1 was found to be linear. A field size dependent response of up to 5% relative to d max ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s-1. The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition

  7. SU-E-T-10: A Dosimetric Comparison of Copper to Lead-Alloy Apertures for Electron Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Rusk, B; Hogstrom, K; Gibbons, J; Carver, R [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States)

    2014-06-01

    Purpose: To evaluate dosimetric differences of copper compared to conventional lead-alloy apertures for electron beam therapy. Methods: Copper apertures were manufactured by .decimal, Inc. and matching lead-alloy, Cerrobend, apertures were constructed for 32 square field sizes (2×2 – 20×20 cm{sup 2}) for five applicator sizes (6×6–25×25 cm{sup 2}). Percent depth-dose and off-axis-dose profiles were measured using an electron diode in water with copper and Cerrobend apertures for a subset of aperture sizes (6×6, 10×10, 25×25 cm{sup 2}) and energies (6, 12, 20 MeV). Dose outputs were measured for all field size-aperture combinations and available energies (6–20 MeV). Measurements were taken at 100 and 110 cm SSDs. Using this data, 2D planar absolute dose distributions were constructed and compared. Passing criteria were ±2% of maximum dose or 1-mm distance-to-agreement for 99% of points. Results: A gamma analysis of the beam dosimetry showed 93 of 96 aperture size, applicator, energy, and SSD combinations passed the 2%/1mm criteria. Failures were found for small field size-large applicator combinations at 20 MeV and 100-cm SSD. Copper apertures showed a decrease in bremsstrahlung production due to copper's lower atomic number compared to Cerrobend (greatest difference was 2.5% at 20 MeV). This effect was most prominent at the highest energies with large amounts of shielding material present (small field size-large applicator). Also, an increase in electrons scattered from the collimator edge of copper compared to Cerrobend resulted in an increased dose at the field edge for copper at shallow depths (greatest increase was 1% at 20 MeV). Conclusion: Apertures for field sizes ≥6×6 cm{sup 2} at any energy, or for small fields (≤4×4 cm{sup 2}) at energies <20 MeV, showed dosimetric differences less than 2%/1mm for more than 99% of points. All field size-applicator size-energy combinations passed 3%/1mm criteria for 100% of points. Work partially

  8. Evaluation of usefulness of portal image using Electronic Portal Imaging Device (EPID) in the patients who received pelvic radiation therapy

    International Nuclear Information System (INIS)

    Kim, Woo Chul; Kim, Heon Jong; Park, Seong Young; Cho, Young Kap; Loh, John J. K.; Park, Won; Suh, Chang Ok; Kim, Gwi Eon

    1998-01-01

    To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film. From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure. Five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 MU/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum, iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated-very clear (1), clear (2), visible (3), notclear (4), not visible (5). Using an video camera based EPID system, there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image quality after window level adjustment. The quality of image acquired using an electronic portal imaging device was

  9. [Cost analysis of intraoperative neurophysiological monitoring (IOM)].

    Science.gov (United States)

    Kombos, T; Suess, O; Brock, M

    2002-01-01

    A number of studies demonstrate that a significant reduction of postoperative neurological deficits can be achieved by applying intraoperative neurophysiological monitoring (IOM) methods. A cost analysis of IOM is imperative considering the strained financial situation in the public health services. The calculation model presented here comprises two cost components: material and personnel. The material costs comprise consumer goods and depreciation of capital goods. The computation base was 200 IOM cases per year. Consumer goods were calculated for each IOM procedure respectively. The following constellation served as a basis for calculating personnel costs: (a) a medical technician (salary level BAT Vc) for one hour per case; (b) a resident (BAT IIa) for the entire duration of the measurement, and (c) a senior resident (BAT Ia) only for supervision. An IOM device consisting of an 8-channel preamplifier, an electrical and acoustic stimulator and special software costs 66,467 euros on the average. With an annual depreciation of 20%, the costs are 13,293 euros per year. This amounts to 66.46 euros per case for the capital goods. For reusable materials a sum of 0.75 euro; per case was calculated. Disposable materials were calculate for each procedure respectively. Total costs of 228.02 euro; per case were,s a sum of 0.75 euros per case was calculated. Disposable materials were calculate for each procedure respectively. Total costs of 228.02 euros per case were, calculated for surgery on the peripheral nervous system. They amount to 196.40 euros per case for spinal interventions and to 347.63 euros per case for more complex spinal operations. Operations in the cerebellopontine angle and brain stem cost 376.63 euros and 397.33 euros per case respectively. IOM costs amount to 328.03 euros per case for surgical management of an intracranial aneurysm and to 537.15 euros per case for functional interventions. Expenses run up to 833.63 euros per case for operations near the

  10. Disparities between resident and attending surgeon perceptions of intraoperative teaching.

    Science.gov (United States)

    Butvidas, Lynn D; Anderson, Cheryl I; Balogh, Daniel; Basson, Marc D

    2011-03-01

    This study aimed to assess attending surgeon and resident recall of good and poor intraoperative teaching experiences and how often these experiences occur at present. By web-based survey, we asked US surgeons and residents to describe their best and worst intraoperative teaching experiences during training and how often 26 common intraoperative teaching behaviors occur in their current environment. A total of 346 residents and 196 surgeons responded (51 programs; 26 states). Surgeons and residents consistently identified trainee autonomy, teacher confidence, and communication as positive, while recalling negatively contemptuous, arrogant, accusatory, or uncommunicative teachers. Residents described intraoperative teaching behaviors by faculty as substantially less frequent than faculty self-reports. Neither sex nor seniority explained these results, although women reported communicative behaviors more frequently than men. Although veteran surgeons and current trainees agree on what constitutes effective and ineffective teaching in the operating room, they disagree on how often these behaviors occur, leaving substantial room for improvement. Published by Elsevier Inc.

  11. Value of intraoperative radiotherapy in locally advanced rectal cancer

    NARCIS (Netherlands)

    Ferenschild, Floris T. J.; Vermaas, Maarten; Nuyttens, Joost J. M. E.; Graveland, Wilfried J.; Marinelli, Andreas W. K. S.; van der Sijp, Joost R.; Wiggers, Theo; Verhoef, Cornelis; Eggermont, Alexander M. M.; de Wilt, Johannes H. W.

    PURPOSE: This study was designed to analyze the results of a multimodality treatment using preoperative radiotherapy, followed by surgery and intraoperative radiotherapy in patients with primary locally advanced rectal cancer. METHODS: Between 1987 and 2002, 123 patients with initial unresectable

  12. Presurgical mapping with magnetic source imaging. Comparisons with intraoperative findings

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Ferrari, P.; Perry, D.; Rowley, H.A.; Berger, M.S.

    2000-01-01

    We compare noninvasive preoperative mapping with magnetic source imaging to intraoperative cortical stimulation mapping. These techniques were directly compared in 17 patients who underwent preoperative and postoperative somatosensory mapping of a total of 22 comparable anatomic sites (digits, face). Our findings are presented in the context of previous studies that used magnetic source imaging and functional magnetic resonance imaging as noninvasive surrogates of intraoperative mapping for the identification of sensorimotor and language-specific brain functional centers in patients with brain tumors. We found that magnetic source imaging results were reasonably concordant with intraoperative mapping findings in over 90% of cases, and that concordance could be defined as 'good' in 77% of cases. Magnetic source imaging therefore provides a viable, if coarse, identification of somatosensory areas and, consequently, can guide and reduce the time taken for intraoperative mapping procedures. (author)

  13. Intraoperative contamination influences wound discharge and periprosthetic infection

    NARCIS (Netherlands)

    Knobben, Bas A. S.; Engelsma, Yde; Neut, Danielle

    Intraoperative bacterial contamination increases risk for postoperative wound-healing problems and periprosthetic infection, but to what extent remains unclear. We asked whether bacterial contamination of the instruments and bone during primary prosthesis insertion was associated with prolonged

  14. Intraoperative management of ETT and LMA cufi pressures: a survey ...

    African Journals Online (AJOL)

    2008-07-16

    Jul 16, 2008 ... A study done by Stein et al. highlighted the inability of advanced life support ... Conclusion. There is increasing importance placed on quality assurance ... pressures – the worrying reality: a comparative audit of intra-operative.

  15. Association between intraoperative hypotension and myocardial injury after vascular surgery

    NARCIS (Netherlands)

    van Waes, JAR; Van Klei, Wilton A.; Wijeysundera, Duminda N.; Van Wolfswinkel, Leo; Lindsay, Thomas F.; Beattie, W. Scott

    2016-01-01

    Background: Postoperative myocardial injury occurs frequently after noncardiac surgery and is strongly associated with mortality. Intraoperative hypotension (IOH) is hypothesized to be a possible cause. The aim of this study was to determine the association between IOH and postoperative myocardial

  16. Intraoperative contamination influences wound discharge and periprosthetic infection

    NARCIS (Netherlands)

    Knobben, Bas A. S.; Engelsma, Yde; Neut, Danielle

    2006-01-01

    Intraoperative bacterial contamination increases risk for postoperative wound-healing problems and periprosthetic infection, but to what extent remains unclear. We asked whether bacterial contamination of the instruments and bone during primary prosthesis insertion was associated with prolonged

  17. Intraoperative transesophageal echocardiography in congenital heart diseases surgery

    International Nuclear Information System (INIS)

    Ozores Suarez, Francisco Javier; Perez de Ordaz, Luis Bravo

    2010-01-01

    The intraoperative transesophageal echocardiography is very used in pediatric cardiovascular surgery. The aim of present paper was to determine its impact on the surgery immediate results after a previous experience of authors with this type of procedure

  18. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  19. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    Science.gov (United States)

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  20. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    OpenAIRE

    Lee, Su-Keon; Lee, Seung-Hwan; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondyloli...

  1. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  2. Long-Term Results of Targeted Intraoperative Radiotherapy (Targit) Boost During Breast-Conserving Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Vaidya, Jayant S., E-mail: jayant.vaidya@ucl.ac.uk [Research Department of Surgery, Division of Surgery and Interventional Science, University College London, London (United Kingdom); Baum, Michael [Research Department of Surgery, Division of Surgery and Interventional Science, University College London, London (United Kingdom); Tobias, Jeffrey S. [Department of Radiation Oncology, University College London Hospitals, London (United Kingdom); Wenz, Frederik [Radiation Oncology and Gynaecology, University Medical Centre of Mannheim (Germany); Massarut, Samuele [Surgery and Radiation Oncology, Centro di Riferimento Oncologico (CRO), Aviano (Italy); Keshtgar, Mohammed [Research Department of Surgery, Division of Surgery and Interventional Science, University College London, London (United Kingdom); Hilaris, Basil [Radiation Oncology, Our Lady of Mercy, New York Medical College, New York (United States); Saunders, Christobel [Institute of Health and Rehabilitation Research, University of Notre Dame, Fremantle, Western Australia (Australia); Williams, Norman R.; Brew-Graves, Chris [Research Department of Surgery, Division of Surgery and Interventional Science, University College London, London (United Kingdom); Corica, Tammy [Institute of Health and Rehabilitation Research, University of Notre Dame, Fremantle, Western Australia (Australia); Roncadin, Mario [Surgery and Radiation Oncology, Centro di Riferimento Oncologico (CRO), Aviano (Italy); Kraus-Tiefenbacher, Uta; Suetterlin, Marc [Radiation Oncology and Gynaecology, University Medical Centre of Mannheim (Germany); Bulsara, Max [Institute of Health and Rehabilitation Research, University of Notre Dame, Fremantle, Western Australia (Australia); Joseph, David [Radiation Oncology, Sir Charles Gairdner Hospital and School of Surgery, University of Western Australia, Perth (Australia)

    2011-11-15

    Purpose: We have previously shown that delivering targeted radiotherapy to the tumour bed intraoperatively is feasible and desirable. In this study, we report on the feasibility, safety, and long-term efficacy of TARGeted Intraoperative radioTherapy (Targit), using the Intrabeam system. Methods and Materials: A total of 300 cancers in 299 unselected patients underwent breast-conserving surgery and Targit as a boost to the tumor bed. After lumpectomy, a single dose of 20 Gy was delivered intraoperatively. Postoperative external beam whole-breast radiotherapy excluded the usual boost. We also performed a novel individualized case control (ICC) analysis that computed the expected recurrences for the cohort by estimating the risk of recurrence for each patient using their characteristics and follow-up period. Results: The treatment was well tolerated. The median follow up was 60.5 months (range, 10-122 months). Eight patients have had ipsilateral recurrence: 5-year Kaplan Meier estimate for ipsilateral recurrence is 1.73% (SE 0.77), which compares well with that seen in the boosted patients in the European Organization for Research and Treatment of Cancer study (4.3%) and the UK STAndardisation of breast RadioTherapy study (2.8%). In a novel ICC analysis of 242 of the patients, we estimated that there should be 11.4 recurrences; in this group, only 6 recurrences were observed. Conclusions: Lumpectomy and Targit boost combined with external beam radiotherapy results in a low local recurrence rate in a standard risk patient population. Accurate localization and the immediacy of the treatment that has a favorable effect on tumour microenvironment may contribute to this effect. These long-term data establish the long-term safety and efficacy of the Targit technique and generate the hypothesis that Targit boost might be superior to an external beam boost in its efficacy and justifies a randomized trial.

  3. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    Science.gov (United States)

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  4. Intraoperative Secondary Insults During Orthopedic Surgery in Traumatic Brain Injury.

    Science.gov (United States)

    Algarra, Nelson N; Lele, Abhijit V; Prathep, Sumidtra; Souter, Michael J; Vavilala, Monica S; Qiu, Qian; Sharma, Deepak

    2017-07-01

    Secondary insults worsen outcomes after traumatic brain injury (TBI). However, data on intraoperative secondary insults are sparse. The primary aim of this study was to examine the prevalence of intraoperative secondary insults during orthopedic surgery after moderate-severe TBI. We also examined the impact of intraoperative secondary insults on postoperative head computed tomographic scan, intracranial pressure (ICP), and escalation of care within 24 hours of surgery. We reviewed medical records of TBI patients 18 years and above with Glasgow Coma Scale score Secondary insults examined were: systemic hypotension (systolic blood pressurehypertension (ICP>20 mm Hg), cerebral hypotension (cerebral perfusion pressure40 mm Hg), hypocarbia (end-tidal CO2hypertension), hyperglycemia (glucose>200 mg/dL), hypoglycemia (glucose38°C). A total of 78 patients (41 [18 to 81] y, 68% male) met the inclusion criteria. The most common intraoperative secondary insults were systemic hypotension (60%), intracranial hypertension and cerebral hypotension (50% and 45%, respectively, in patients with ICP monitoring), hypercarbia (32%), and hypocarbia (29%). Intraoperative secondary insults were associated with worsening of head computed tomography, postoperative decrease of Glasgow Coma Scale score by ≥2, and escalation of care. After Bonferroni correction, association between cerebral hypotension and postoperative escalation of care remained significant (Psecondary insults were common during orthopedic surgery in patients with TBI and were associated with postoperative escalation of care. Strategies to minimize intraoperative secondary insults are needed.

  5. Intraoperative complications in pediatric neurosurgery: review of 1807 cases.

    Science.gov (United States)

    van Lindert, Erik J; Arts, Sebastian; Blok, Laura M; Hendriks, Mark P; Tielens, Luc; van Bilsen, Martine; Delye, Hans

    2016-09-01

    OBJECTIVE Minimal literature exists on the intraoperative complication rate of pediatric neurosurgical procedures with respect to both surgical and anesthesiological complications. The aim of this study, therefore, was to establish intraoperative complication rates to provide patients and parents with information on which to base their informed consent and to establish a baseline for further targeted improvement of pediatric neurosurgical care. METHODS A clinical complication registration database comprising a consecutive cohort of all pediatric neurosurgical procedures carried out in a general neurosurgical department from January 1, 2004, until July 1, 2012, was analyzed. During the study period, 1807 procedures were performed on patients below the age of 17 years. RESULTS Sixty-four intraoperative complications occurred in 62 patients (3.5% of procedures). Intraoperative mortality was 0.17% (n = 3). Seventy-eight percent of the complications (n = 50) were related to the neurosurgical procedures, whereas 22% (n = 14) were due to anesthesiology. The highest intraoperative complication rates were for cerebrovascular surgery (7.7%) and tumor surgery (7.4%). The most frequently occurring complications were cerebrovascular complications (33%). CONCLUSIONS Intraoperative complications are not exceptional during pediatric neurosurgical procedures. Awareness of these complications is the first step in preventing them.

  6. Intraoperative MRI to control the extent of brain tumor surgery

    International Nuclear Information System (INIS)

    Knauth, M.; Sartor, K.; Wirtz, C.R.; Tronnier, V.M.; Staubert, A.; Kunze, S.

    1998-01-01

    Intraoperative MRI definitely showed residual tumor in 6 of the 18 patients and resulted in ambiguous findings in 3 patients. In 7 patients surgery was continued. Early postoperative MRI showed residual tumor in 3 patients and resulted in uncertain findings in 2 patients. The rate of patients in whom complete removal of enhancing tumor could be achieved was 50% at the time of the intraoperative MR examination and 72% at the time of the early postoperative MR control. The difference in proportion of patients with 'complete tumor removal' between the groups who had been operated on using neuronavigation (NN) and intraoperative MRI (ioMRI) and those who had been operated on using only modern neurosurgical techniques except NN and ioMRI was statistically highly significant (Fisher exact test; P=0.008). Four different types of surgically induced contrast enhancement were observed. These phenomena carry different confounding potentials with residual tumor. Conclusion: Our preliminary experience with intraoperative MRI in patients with enhancing intraaxial tumors is encouraging. Combined use of neuronavigation and intraoperative MRI was able to increase the proportion of patients in whom complete removal of the enhancing parts of the tumor was achieved. Surgically induced enhancement requires careful analysis of the intraoperative MRI in order not to confuse it with residual tumor. (orig.) [de

  7. Selective serotonin reuptake inhibitors and intraoperative blood pressure.

    Science.gov (United States)

    van Haelst, Ingrid M M; van Klei, Wilton A; Doodeman, Hieronymus J; Kalkman, Cor J; Egberts, Toine C G

    2012-02-01

    The influence of selective serotonin reuptake inhibitors (SSRIs) on blood pressure is poorly understood. We hypothesized that if SSRIs have an influence on blood pressure, this might become manifest in changes in intraoperative blood pressure. We aimed to study the association between perioperative use of SSRIs and changes in intraoperative blood pressure by measuring the occurrence of intraoperative hyper- and hypotension. We conducted a retrospective observational follow-up study among patients who underwent elective primary total hip arthroplasty. The index group included users of SSRIs. The reference group included a random sample (ratio 1:3) of nonusers of an antidepressant agent. The outcome was the occurrence of intraoperative hypo- and hypertensive episodes (number, mean and total duration, and area under the curve (AUC)). The outcome was adjusted for confounding factors using regression techniques. The index group included 20 users of an SSRI. The reference group included 60 nonusers. Users of SSRIs showed fewer intraoperative hypotensive episodes, a shorter mean and total duration, and a smaller AUC when compared to the reference group. After adjustment for confounders, SSRI use was associated with a significantly shorter total duration of hypotension: mean difference of -29.4 min (95% confidence interval (CI) -50.4 to -8.3). Two users of an SSRI and two patients in the reference group had a hypertensive episode. Continuation of treatment with SSRIs before surgery was associated with a briefer duration of intraoperative hypotension.

  8. InsuOnline, an Electronic Game for Medical Education on Insulin Therapy: A Randomized Controlled Trial With Primary Care Physicians.

    Science.gov (United States)

    Diehl, Leandro Arthur; Souza, Rodrigo Martins; Gordan, Pedro Alejandro; Esteves, Roberto Zonato; Coelho, Izabel Cristina Meister

    2017-03-09

    Most patients with diabetes mellitus (DM) are followed by primary care physicians, who often lack knowledge or confidence to prescribe insulin properly. This contributes to clinical inertia and poor glycemic control. Effectiveness of traditional continuing medical education (CME) to solve that is limited, so new approaches are required. Electronic games are a good option, as they can be very effective and easily disseminated. The objective of our study was to assess applicability, user acceptance, and educational effectiveness of InsuOnline, an electronic serious game for medical education on insulin therapy for DM, compared with a traditional CME activity. Primary care physicians (PCPs) from South of Brazil were invited by phone or email to participate in an unblinded randomized controlled trial and randomly allocated to play the game InsuOnline, installed as an app in their own computers, at the time of their choice, with minimal or no external guidance, or to participate in a traditional CME session, composed by onsite lectures and cases discussion. Both interventions had the same content and duration (~4 h). Applicability was assessed by the number of subjects who completed the assigned intervention in each group. Insulin-prescribing competence (factual knowledge, problem-solving skills, and attitudes) was self-assessed through a questionnaire applied before, immediately after, and 3 months after the interventions. Acceptance of the intervention (satisfaction and perceived importance for clinical practice) was also assessed immediately after and 3 months after the interventions, respectively. Subjects' characteristics were similar between groups (mean age 38, 51.4% [69/134] male). In the game group, 69 of 88 (78%) completed the intervention, compared with 65 of 73 (89%) in the control group, with no difference in applicability. Percentage of right answers in the competence subscale, which was 52% at the baseline in both groups, significantly improved

  9. InsuOnline, an Electronic Game for Medical Education on Insulin Therapy: A Randomized Controlled Trial With Primary Care Physicians

    Science.gov (United States)

    2017-01-01

    Background Most patients with diabetes mellitus (DM) are followed by primary care physicians, who often lack knowledge or confidence to prescribe insulin properly. This contributes to clinical inertia and poor glycemic control. Effectiveness of traditional continuing medical education (CME) to solve that is limited, so new approaches are required. Electronic games are a good option, as they can be very effective and easily disseminated. Objective The objective of our study was to assess applicability, user acceptance, and educational effectiveness of InsuOnline, an electronic serious game for medical education on insulin therapy for DM, compared with a traditional CME activity. Methods Primary care physicians (PCPs) from South of Brazil were invited by phone or email to participate in an unblinded randomized controlled trial and randomly allocated to play the game InsuOnline, installed as an app in their own computers, at the time of their choice, with minimal or no external guidance, or to participate in a traditional CME session, composed by onsite lectures and cases discussion. Both interventions had the same content and duration (~4 h). Applicability was assessed by the number of subjects who completed the assigned intervention in each group. Insulin-prescribing competence (factual knowledge, problem-solving skills, and attitudes) was self-assessed through a questionnaire applied before, immediately after, and 3 months after the interventions. Acceptance of the intervention (satisfaction and perceived importance for clinical practice) was also assessed immediately after and 3 months after the interventions, respectively. Results Subjects’ characteristics were similar between groups (mean age 38, 51.4% [69/134] male). In the game group, 69 of 88 (78%) completed the intervention, compared with 65 of 73 (89%) in the control group, with no difference in applicability. Percentage of right answers in the competence subscale, which was 52% at the baseline in both

  10. Intraoperative HDR brachytherapy for rectal cancer using a flexible intraoperative template: standard plans versus individual planning

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Nuyttens, Joost J.; Hanssens, Patrick E.J.; Levendag, Peter C.

    2004-01-01

    HDR intraoperative brachytherapy (IOBT) is applied to locally advanced rectal tumors using a 5 mm thick flexible intraoperative template (FIT). To reduce the procedure time, treatment planning is performed using standard plans that neglect the curvature of the FIT. We have calculated the individual treatment plan, based on the real geometry of the FIT, and the dose at clips placed during surgery. A mean treatment dose of 9.55±0.21 Gy was found for the individual plan, compared to the prescribed 10 Gy (P<0.0001). The mean central dose was 10.03±0.10 Gy in the standard plan and 9.20±0.32 Gy in the individual plan (P<0.0001). The mean dose at the corners of the FIT was 10.3 Gy in the standard plan and ranged between 10.3 and 10.5 Gy in the individual plan. In 63% of the clips, the dose was larger than 15.0 Gy, which is equivalent to a gap between the FIT and the target smaller than 5 mm. In 18% of the clips, the dose was smaller than 13.0 Gy indicating that locally the gap was larger than 5 mm. Clinical practice will have to prove if these small dose deviations influence the clinical outcome

  11. Total Skin Electron Therapy for Cutaneous T-Cell Lymphoma Using a Modern Dual-Field Rotational Technique

    Energy Technology Data Exchange (ETDEWEB)

    Heumann, Thatcher R. [Emory University School of Medicine, Emory University, Atlanta, Georgia (United States); Esiashvili, Natia [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute (WCI), Emory University, Atlanta, Georgia (United States); Parker, Sareeta [Department of Dermatology, Emory University, Atlanta, Georgia (United States); Switchenko, Jeffrey M. [Biostatistics Shared Core Resource at WCI, Emory University, Atlanta, Georgia (United States); Dhabbaan, Anees [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute (WCI), Emory University, Atlanta, Georgia (United States); Goodman, Michael [Department of Epidemiology, Rollins School of Public Health, Emory University, Atlanta, Georgia (United States); Lechowicz, Mary Jo; Flowers, Christopher R. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Department of Hematology and Oncology, Emory University, Atlanta, Georgia (United States); Khan, Mohammad K., E-mail: drkhurram2000@gmail.com [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute (WCI), Emory University, Atlanta, Georgia (United States)

    2015-05-01

    Purpose: To report our experience with rotational total skin electron irradiation (RTSEI) in cutaneous T-cell lymphoma (CTCL), and to examine response by disease stage and race. Methods and Materials: We reviewed our outcomes for 68 CTCL patients who received RTSEI (≥30 Gy) from 2000 to 2013. Primary outcomes were complete clinical response (CCR), recurrence-free survival (RFS), and overall survival (OS). Using log–rank tests and Cox proportional hazards, OS and RFS were compared across tumor stages at time of RTSEI with further racial subgroup analysis. Results: Median age at diagnosis and at time of radiation was 52 and 56 years, respectively. Median follow-up was 5.1 years, 49% were African American, and 49% were female. At time of treatment, 18, 37, and 13 patients were T stage 2, 3, and 4, respectively. At 6 weeks after RTSEI, overall CCR was 82% (88%, 83%, and 69% for T2, T3, and T4, respectively). Median RFS was 11 months for all patients and 14, 10, and 12 months for stage T2, T3, and T4, respectively. Tumor stage was not associated with RFS or CCR. Maintenance therapy after RTSEI was associated with improved RFS in both crude and multivariable analysis, controlling for T stage. Median OS was 76 months (91 and 59 months for T3 and T4, respectively). With the exception of improved OS in African Americans compared with whites at stage T2, race was not associated with CCR, RFS, or OS. Conclusions: These results represent the largest RTSEI clinical outcomes study in the modern era using a dual-field rotational technique. Our observed response rates match or improve upon the standard set by previous outcome studies using conventional TSEI techniques, despite a large percentage of advanced CTCL lesions in our cohort. We found that clinical response after RTSEI did not seem to be affected by T stage or race.

  12. Total Skin Electron Beam Therapy in the Treatment of Mycosis Fungoides: A Review of Conventional and Low-Dose Regimens.

    Science.gov (United States)

    Chowdhary, Mudit; Chhabra, Arpit M; Kharod, Shivam; Marwaha, Gaurav

    2016-12-01

    Mycosis fungoides (MF) is the most prevalent subtype of cutaneous T-cell lymphoma, which is characterized by the proliferation of CD4 + T cells. While often an indolent disease, most patients eventually develop progression from isolated patches to tumors and finally nodal or visceral involvement. Treatment choice is largely based on disease burden, though prognostic factors such as disease stage, patient age, and extracutaneous involvement must be taken into consideration. Radiotherapy represents one of the most effective therapeutic modalities in the treatment of MF. Lymphocytes are exquisitely radiosensitive, and excellent responses are observed even with low doses of radiation. Total skin electron beam therapy (TSEBT) is a special technique that allows for the homogenous irradiation of the entire skin. There are well-documented radiation dose-response relationships for achieving a complete response. As such, TSEBT doses ≥ 30 Gy comprise the current standard of care. Although highly effective, most patients experience recurrent disease even after conventional-dose (≥ 30 Gy) TSEBT. In addition, toxicity is cumulatively dose dependent, and there is reluctance to administer multiple courses of conventional-dose TSEBT. Consequently, there has been renewed interest in determining the utility of TSEBT at lower total (≤ 30 Gy) doses. Advantages of low-total-dose (with standard dose per fraction) TSEBT include a shortened treatment course, the potential to minimize the risk of adverse events, and the opportunity to allow for retreatment in cases of disease recurrence. This comprehensive review compares the impact of different TSEBT dosing schemes on clinical outcomes of MF. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Intraoperative Boost Radiotherapy during Targeted Oncoplastic Breast Surgery: Overview and Single Center Experiences

    Directory of Open Access Journals (Sweden)

    Wolfram Malter

    2014-01-01

    Full Text Available Breast-conserving surgery followed by whole-breast irradiation is the standard local therapy for early breast cancer. The international discussion of reduced importance of wider tumor-free resection margins than “tumor not touching ink” leads to the development of five principles in targeted oncoplastic breast surgery. IORT improves local recurrence risk and diminishes toxicity since there is less irradiation of healthy tissue. Intraoperative radiotherapy (IORT can be delivered in two settings: an IORT boost followed by a conventional regimen of external beam radiotherapy or a single IORT dose. The data from TARGIT-A and ELIOT reinforce the conviction that intraoperative radiotherapy during breast-conserving surgery is a reliable alternative to conventional postoperative fractionated irradiation, but only in a carefully selected population at low risk of local recurrence. We describe our experiences with IORT boost (50 kV energy X-rays; 20 Gy in combination with targeted oncoplastic breast surgery in a routine clinical setting. Our experiences demonstrate the applicability and reliability of combining IORT boost with targeted oncoplastic breast surgery in breast-conserving therapy of early breast cancer.

  14. How do pediatric anesthesiologists define intraoperative hypotension?

    Science.gov (United States)

    Nafiu, Olubukola O; Voepel-Lewis, Terri; Morris, Michelle; Chimbira, Wilson T; Malviya, Shobha; Reynolds, Paul I; Tremper, Kevin K

    2009-11-01

    Although blood pressure (BP) monitoring is a recommended standard of care by the ASA, and pediatric anesthesiologists routinely monitor the BP of their patients and when appropriate treat deviations from 'normal', there is no robust definition of hypotension in any of the pediatric anesthesia texts or journals. Consequently, what constitutes hypotension in pediatric anesthesia is currently unknown. We designed a questionnaire-based survey of pediatric anesthesiologists to determine the BP ranges and thresholds used to define intraoperative hypotension (IOH). Members of the Society of Pediatric Anesthesia (SPA) and the Association of Paediatric Anaesthetists (APA) of Great Britain and Ireland were contacted through e-mail to participate in this survey. We asked a few demographic questions and five questions about specific definitions of hypotension for different age groups of patients undergoing inguinal herniorraphy, a common pediatric surgical procedure. The overall response rate was 56% (483/860), of which 76% were SPA members. Majority of the respondents (72%) work in academic institutions, while 8.9% work in institutions with fewer than 1000 annual pediatric surgical caseload. About 76% of respondents indicated that a 20-30% reduction in baseline systolic blood pressure (SBP) indicates significant hypotension in children under anesthesia. Most responders (86.7%) indicated that they use mean arterial pressure or SBP (72%) to define IOH. The mean SBP values for hypotension quoted by SPA members was about 5-7% lower across all pediatric age groups compared to values quoted by APA members (P = 0.001 for all age groups). There is great variability in the BP parameters used and the threshold used for defining and treating IOH among pediatric anesthesiologists. The majority of respondents considered a 20-30% reduction from baseline in SBP as indicative of significant hypotension. Lack of a consensus definition for a common clinical condition like IOH could have

  15. Automated intraoperative calibration for prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Kuiran Chen, Thomas; Heffter, Tamas; Lasso, Andras; Pinter, Csaba; Abolmaesumi, Purang; Burdette, E. Clif; Fichtinger, Gabor

    2011-01-01

    Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

  16. Neurophysiologic intraoperative monitoring of the vestibulocochlear nerve.

    Science.gov (United States)

    Simon, Mirela V

    2011-12-01

    Neurosurgical procedures involving the skull base and structures within can pose a significant risk of damage to the brain stem and cranial nerves. This can have life-threatening consequences and/or result in devastating neurologic deficits. Over the past decade, intraoperative neurophysiology has significantly evolved and currently offers a great tool for live monitoring of the integrity of nervous structures. Thus, dysfunction can be identified early and prompt modification of the surgical management or operating conditions, leads to avoidance of permanent structural damage.Along these lines, the vestibulocochlear nerve (CN VIII) and, to a greater extent, the auditory pathways as they pass through the brain stem are especially at risk during cerebelopontine angle (CPA), posterior/middle fossa, or brain stem surgery. CN VIII can be damaged by several mechanisms, from vascular compromise to mechanical injury by stretch, compression, dissection, and heat injury. Additionally, cochlea itself can be significantly damaged during temporal bone drilling, by noise, mechanical destruction, or infarction, and because of rupture, occlusion, or vasospasm of the internal auditory artery.CN VIII monitoring can be successfully achieved by live recording of the function of one of its parts, the cochlear or auditory nerve (AN), using the brain stem auditory evoked potentials (BAEPs), electrocochleography (ECochG), and compound nerve action potentials (CNAPs) of the cochlear nerve.This is a review of these techniques, their principle, applications, methodology, interpretation of the evoked responses, and their change from baseline, within the context of surgical and anesthesia environments, and finally the appropriate management of these changes.

  17. The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC.

    Science.gov (United States)

    Mosalaei, Homeira; Karnas, Scott; Shah, Sheel; Van Doodewaard, Sharon; Foster, Tim; Chen, Jeff

    2012-01-01

    Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  18. MO-H-19A-02: Investigation of Modulated Electron Arc (MeArc) Therapy for the Treatment of Scalp Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A [Fox Chase Cancer Center, Philadelphia, PA (United States); Al-Azhar University, Cairo (Egypt); Jin, L; Martin, J; Li, J; Chibani, O; Galloway, T; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-15

    Purpose: Electron arc therapy has long been proposed as the most suitable technique for the treatment of superficial tumors that follow circularly curved surfaces. However it was challenged by unsuitability of the conventional applicators and the lack of adequate 3-D dose calculation tools for arc electron beams in the treatment planning systems (TPS). Now with the availability of an electron specific multi-leaf collimator (eMLC) and an in-house Monte Carlo (MC) based TPS, we were motivated to investigate more advanced modulated electron arc (MeARC) therapy and its beneficial outcome. Methods: We initiated the study by a film measurement conducted in a head and neck phantom, where we delivered electron arcs in a step and shoot manner using the light field as a guide to avoid fields abutments. This step was done to insure enough clearance for the arcs with eMLC. MCBEAM and MCPLAN MC codes were used for the treatment head simulation and phantom dose calculation, respectively. Treatment plans were generated for targets drawn in real patient CTs and head and neck phantom. We utilized beams eye view available from a commercial planning system to create beamlets having same isocenter and adjoined at the scalp surface. Then dose-deposition coefficients from those beamlets were calculated for all electron energies using MCPLAN. An in-house optimization code was then used to find the optimum weights needed from individual beamlets. Results: MeARC showed a nicely tailored dose distribution around the circular curved target on the scalp. Some hot spots were noticed and could be attributed to fields abutment problem owing to the bulging nature of electron profiles. Brain dose was shown to be at lower levels compared to photon treatment. Conclusion: MeARC was shown to be a promising modality for treating scalp cases and could be beneficial to all superficial tumors with a circular curvature.

  19. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  20. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    Science.gov (United States)

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-valuestones (stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  1. Intraoperative radiotherapy in resected pancreatic cancer: feasibility and results

    International Nuclear Information System (INIS)

    Coquard, Regis; Ayzac, Louis; Gilly, Francois-Noeel; Romestaing, Pascale; Ardiet, Jean-Michel; Sondaz, Chrystel; Sotton, Marie-Pierre; Sentenac, Irenee; Braillon, Georges; Gerard, Jean-Pierre

    1997-01-01

    Background and purpose: To evaluate the impact of intraoperative radiotherapy (IORT) combined with postoperative external beam irradiation in patients with pancreatic cancer treated with curative surgical resection. Materials and methods: From January 1986 to April 1995 25 patients (11 male and 14 female, median age 61 years) underwent a curative resection with IORT for pancreatic adenocarcinoma. The tumour was located in the head of the pancreatic gland in 22 patients, in the body in two patients and in the tail in one patient. The pathological stage was pT1 in nine patients, pT2 in nine patients, pT3 in seven patients, pN0 in 14 patients and pN1 in 11 patients. All the patients were pM0. A pancreaticoduodenectomy was performed in 22 patients, a distal pancreatectomy was performed in two patients and a total pancreatectomy was performed in one patient. The resection was considered to be complete in 20 patients. One patient had microscopic residual disease and gross residual disease was present in four patients. IORT using electrons with a median energy of 12 MeV was performed in all the patients with doses ranging from 12 to 25 Gy. Postoperative EBRT was delivered to 20 patients (median dose 44 Gy). Concurrent chemotherapy with 5-fluorouracil was given to seven patients. Results: The overall survival was 56% at 1 year, 20% at 2 years and 10% at 5 years. Nine local failures were observed. Twelve patients developed metastases without local recurrence. Twenty patients died from tumour progression and two patients died from early post-operative complications. Three patients are still alive; two patients in complete response at 17 and 94 months and one patient with hepatic metastases at 13 months. Conclusion: IORT after complete resection combined with postoperative external beam irradiation is feasible and well tolerated in patients with pancreatic adenocarcinoma

  2. Technical advances in radiation therapy

    International Nuclear Information System (INIS)

    Sause, W.T.

    1986-01-01

    Substantial advances have been made in radiation therapy. Many of these advances can be applied in most radiation therapy departments without expensive improvements in equipment. Changes in radiation fractionation, chemotherapeutic sensitization, intraoperative radiation, and interstitial implants can be performed with experience and improved physician training in most medium-sized departments. Advances that require investments in expensive equipment such as particle radiation and hyperthermia will need to be evaluated at designated treatment centers. 106 references

  3. The use of intraoperative computed tomography navigation in pituitary surgery promises a better intraoperative orientation in special cases

    Directory of Open Access Journals (Sweden)

    Stefan Linsler

    2016-01-01

    Full Text Available Objective: The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT and magnetic resonance imaging (MRI. Here, we report our initial experience of real-time intraoperative CT-guided navigation surgery for pituitary tumors in childhood. Materials and Methods: We report the case of a 15-year-old girl with a huge growth hormone-secreting pituitary adenoma with supra- and perisellar extension. Furthermore, the skull base was infiltrated. In this case, we performed an endonasal transsphenoidal approach for debulking the adenoma and for chiasma decompression. We used an MRI neuronavigation (Medtronic Stealth Air System which was registered via intraoperative CT scan (Siemens CT Somatom. Preexisting MRI studies (navigation protocol were fused with the intraoperative CT scans to enable three-dimensional navigation based on MR and CT imaging data. Intraoperatively, we did a further CT scan for resection control. Results: The intraoperative accuracy of the neuronavigation was excellent. There was an adjustment of <1 mm. The navigation was very helpful for orientation on the destroyed skull base in the sphenoid sinus. After opening the sellar region and tumor debulking, we did a CT scan for resection control because the extent of resection was not credible evaluable in this huge infiltrating adenoma. Thereby, we were able to demonstrate a sufficient decompression of the chiasma and complete resection of the medial part of the adenoma in the intraoperative CT images. Conclusions: The use of intraoperative CT/MRI-guided neuronavigation for transsphenoidal surgery is a time-effective, safe, and technically beneficial technique for special cases.

  4. Intraoperative use of ultrasonography by small subcortical lesions

    International Nuclear Information System (INIS)

    Kondoff, Sl.; Gabrovski, St.; Krustev, E.; Poptodorov, G.; Gabrovski, N.; Uzunov, K.

    2004-01-01

    The aim of this study is to present the possibilities for use of intraoperative ultrasound (US) diagnostics as a method of image guided surgical navigation in neurosurgery. During an US scan of normal and pathologically changed tissues as well as volume taking lesion images are received in real time intraoperative display allowing dynamic control of the surgical radicalism and at the same time minimal invasiveness to the neural structures. Intraoperative ultrasound with real-time display characteristics finds a very wide application: subcortical and deeply localized tumour lesions, haematomas, large and giant aneurysms, arteriovenous (AV) malformations, spinal tumours and cysts. The real time dynamic scan is based on the B-mod. This method is founded on the US characteristic of reflecting in a different manner at the borderline of two mediums with different density as well as tissues with various physical and chemical characteristics. The reflection is partially absorbed depending on the acoustic impedance of the biologic field. We use a LOGIC200PRO unit with two probes I-type and T-type having a 'wedge of space' - 35 mm and working frequencies of 6 MHz and 7 MHz appropriate for visualizing lesions at a depth of 25 to 60 mm.The advantages of the Intraoperative US diagnostics are: non-invasiveness; real time display - i.e. presents the imminent intraoperative changes; it is a good alternative to other image-guided technologies; accessible price of the US unit

  5. Selected versus routine use of intraoperative cholangiography during laparoscopic cholecystectomy.

    Science.gov (United States)

    Pickuth, D

    1995-12-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments, however, this is discussed controversially. We have developed a new diagnostic strategy to detect bile duct stones. The concept is based on an ultrasound examination and on a screening for the presence of six risk indicators of choledocholithiasis. 120 consecutive patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of six risk indicators of choledocholithiasis: history of jaundice; history of pancreatitis; hyperbilirubinemia; hyperamylasemia; dilated bile duct; unclear ultrasound findings. The sensitivity of ultrasound and of intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. 20% of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (p concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that the routine use of intraoperative cholangiography in patients undergoing laparoscopic cholecystectomy is not necessary.

  6. Role of scrape cytology in the intraoperative diagnosis of tumor

    Directory of Open Access Journals (Sweden)

    Kolte Sachin

    2010-01-01

    Full Text Available Background : Rapid diagnosis of surgically removed specimens has created many controversies and a single completely reliable method has not yet been developed. Histopathology of a paraffin section remains the ultimate gold standard in tissue diagnosis. Frozen section is routinely used by the surgical pathology laboratories for intraoperative diagnosis. The use of either frozen section or cytological examination alone has an acceptable rate (93-97% of correct diagnosis, with regard to interpretation of benign versus malignant. Aim : To evaluate the utility of scrape cytology for the rapid diagnosis of surgically removed tumors and its utilisation for learning cytopathology. Materials and Methods : 75 surgically removed specimens from various organs and systems were studied. Scrapings were taken from each specimen before formalin fixation and stained by modified rapid Papanicolaou staining. Results : Of the 75 cases studied, 73 could be correctly differentiated into benign and malignant tumors, with an accuracy rate of 97.3%. Conclusions : Intraoperative scrape cytology is useful for intraoperative diagnosis of tumor, where facilities for frozen section are not available. The skill and expertise developed by routinely practicing intraoperative cytology can be applied to the interpretation of fine needle aspirate smears. Thus, apart from its diagnostic role, intraoperative cytology can become a very useful learning tool in the field of cytopathology.

  7. [Factors related to intraoperative retinal breaks in macular hole surgery].

    Science.gov (United States)

    Kumagai, K; Ogino, N; Demizu, S; Atsumi, K; Kurihara, H; Iwaki, M; Ishigooka, H; Tachi, N

    2001-02-01

    To evaluate the factors of intraoperative retinal breaks in macular hole surgery. This study included 558 eyes of 506 patients who underwent idiopathic macular hole surgery by one surgeon. Multiple regression was performed using the variables of gender, age, affected eye, lens status, stage, duration of symptoms, hole size, axial length, and lattice degeneration. The rate of retinal breaks was higher in stage 3 (16.0%) than in stage 4 (8.2%) (p = 0.014). In eyes with lattice degeneration intraoperative retinal breaks occurred in about 40% of the cases. Major factors were as follows: lattice degeneration (r = 0.24, p lattice degeneration, and gender (r = -0.18, p = 0.035) in eyes of stage 4 without lattice degeneration. The factors of intraoperative retinal breaks in macular hole surgery were lattice degeneration in all eyes and stage 3 in eyes without lattice degeneration. The high incidence of intraoperative retinal breaks in stage 3 was mainly due to the occurrence of posterior vitreous detachment. Male gender was a significant factor associated with intraoperative retinal breaks.

  8. Intraoperative parathyroid hormone assay-cutting the Gordian knot

    Directory of Open Access Journals (Sweden)

    Chandralekha Tampi

    2014-01-01

    Full Text Available Background: Hyperparathyroidism is treated by surgical excision of the hyperfunctioning parathyroid gland. In case of adenoma the single abnormal gland is removed, while in hyperplasias, a subtotal excision, that is, three-and-a-half of the four glands are removed. This therapeutic decision is made intraoperatively through frozen section evaluation and is sometimes problematic, due to a histological overlap between hyperplasia and the adenoma. The intraoperative parathyroid hormone (IOPTH assay, propogated in recent years, offers an elegant solution, with a high success rate, due to its ability to identify the removal of all hyperfunctioning parathyroid tissue. Aim: To study the feasibility of using IOPTH in our setting. Materials and Methods: Seven patients undergoing surgery for primary hyperparathyroidism had their IOPTH levels evaluated, along with the routine frozen and paraffin sections. Results: All seven patients showed more than a 50% intraoperative fall in serum PTH after excision of the abnormal gland. This was indicative of an adenoma and was confirmed by histopathological examination and normalization of serum calcium postoperatively. Conclusion: The intraoperative parathyroid hormone is a sensitive and specific guide to a complete removal of the abnormal parathyroid tissue. It can be incorporated without difficulty as an intraoperative guide and is superior to frozen section diagnosis in parathyroid surgery.

  9. Intraoperative adverse events associated with extremely preterm cesarean deliveries.

    Science.gov (United States)

    Bertholdt, Charline; Menard, Sophie; Delorme, Pierre; Lamau, Marie-Charlotte; Goffinet, François; Le Ray, Camille

    2018-05-01

    At the same time as survival is increasing among premature babies born before 26 weeks of gestation, the rates of cesarean deliveries before 26 weeks is also rising. Our purpose was to compare the frequency of intraoperative adverse events during cesarean deliveries in two gestational age groups: 24-25 weeks and 26-27 weeks. This single-center retrospective cohort study included all women with cesarean deliveries performed before 28 +0 weeks from 2007 through 2015. It compared the frequency of intraoperative adverse events between two groups: those at 24-25 weeks of gestation and at 26-27 weeks. Intraoperative adverse events were a classical incision, transplacental incision, difficulty in fetal extraction (explicitly mentioned in the surgical report), postpartum hemorrhage (≥500 mL of blood loss), and injury to internal organs. A composite outcome including at least one of these events enabled us to analyze the risk factors for intraoperative adverse events with univariate and multivariable analysis. Stratified analyses by the indication for the cesarean were performed. We compared 74 cesarean deliveries at 24-25 weeks of gestation and 214 at 26-27 weeks. Intraoperative adverse events occurred at higher rates in the 24-25-week group (63.5 vs. 30.8%, p cesarean. These results should help obstetricians and women making decisions about cesarean deliveries at these extremely low gestational ages. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  10. Intraoperative and early postoperative complications of manual sutureless cataract extraction.

    Science.gov (United States)

    Iqbal, Yasir; Zia, Sohail; Baig Mirza, Aneeq Ullah

    2014-04-01

    To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Case series. Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema.

  11. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    Science.gov (United States)

    Chytyk-Praznik, Krista Joy

    Radiation therapy is continuously increasing in complexity due to technological innovation in delivery techniques, necessitating thorough dosimetric verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate enough to use in a clinical setting. All measured images in this work were obtained with an amorphous silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo simulations and schematics of the linear accelerator. The fluence incident on the EPID was converted to a portal dose image through a superposition of Monte Carlo-generated, monoenergetic dose kernels specific to the a-Si EPID. Predictions of clinical IMRT fields with no patient present agreed with measured portal dose images within 3% and 3 mm. The dose kernels were applied ignoring the geometrically divergent nature of incident fluence on the EPID. A computational investigation into this parallel dose kernel assumption determined its validity under clinically relevant situations. Introducing a patient or phantom into the beam required the portal image prediction algorithm to account for patient scatter and attenuation. Primary fluence was calculated by attenuating raylines cast through the patient CT dataset, while scatter fluence was determined through the superposition of pre-calculated scatter fluence kernels. Total dose in the EPID was calculated by convolving the total predicted incident fluence with the EPID-specific dose kernels. The algorithm was tested on water slabs with square fields, agreeing with measurement within 3% and 3 mm. The

  12. Very high-energy electron (VHEE) beams in radiation therapy; Treatment plan comparison between VHEE, VMAT, and PPBS.

    Science.gov (United States)

    Schüler, Emil; Eriksson, Kjell; Hynning, Elin; Hancock, Steven L; Hiniker, Susan M; Bazalova-Carter, Magdalena; Wong, Tony; Le, Quynh-Thu; Loo, Billy W; Maxim, Peter G

    2017-06-01

    The aim of this study was to evaluate the performance of very high-energy electron beams (VHEE) in comparison to clinically derived treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PPBS) technology. We developed a custom optimization script that could be applied automatically across modalities to eliminate operator bias during IMRT optimization. Four clinical cases were selected (prostate cancer, lung cancer, pediatric brain tumor, and head and neck cancer (HNC)). The VHEE beams were calculated in the EGSnrc/DOSXYZnrc Monte Carlo code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PPBS were optimized in a research version of RayStation using an in-house developed script to minimize operator bias between the different techniques. The in-house developed script generated similar or superior plans to the clinically used plans. In the comparisons between the modalities, the integral dose was lowest for the PPBS-generated plans in all cases. For the prostate case, the 200 MeV VHEE plan showed reduced integral dose and reduced organ at risk (OAR) dose compared to the VMAT plan. For all other cases, both the 100 and the 200 MeV VHEE plans were superior to the VMAT plans, and the VHEE plans showed better conformity and lower spinal cord dose in the pediatric brain case and lower brain stem dose in the HNC case when compared to the PPBS plan. The automated optimization developed in this study generated similar or superior plans as compared to the clinically used plan and represents an unbiased approach to compare treatment plans generated for different modalities. In the present study, we also show that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases, and VHEE plans can even achieve reductions in OAR doses compared to PPBS plans for shallow targets. With increased VHEE energy, better conformity and even higher

  13. MO-AB-BRA-08: Rapid Treatment Field Uniformity Optimization for Total Skin Electron Beam Therapy Using Cherenkov Imaging

    International Nuclear Information System (INIS)

    Andreozzi, J; Zhang, R; Glaser, A; Pogue, B; Jarvis, L; Williams, B; Gladstone, D

    2015-01-01

    Purpose: To evaluate treatment field heterogeneity resulting from gantry angle choice in total skin electron beam therapy (TSEBT) following a modified Stanford dual-field technique, and determine a relationship between source to surface distance (SSD) and optimized gantry angle spread. Methods: Cherenkov imaging was used to image 62 treatment fields on a sheet of 1.2m x 2.2m x 1.2cm polyethylene following standard TSEBT setup at our institution (6 MeV, 888 MU/min, no spoiler, SSD=441cm), where gantry angles spanned from 239.5° to 300.5° at 1° increments. Average Cherenkov intensity and coefficient of variation in the region of interest were compared for the set of composite Cherenkov images created by summing all unique combinations of angle pairs to simulate dual-field treatment. The angle pair which produced the lowest coefficient of variation was further studied using an ionization chamber. The experiment was repeated at SSD=300cm, and SSD=370.5cm. Cherenkov imaging was also implemented during TSEBT of three patients. Results: The most uniform treatment region from a symmetric angle spread was achieved using gantry angles +/−17.5° about the horizontal axis at SSD=441cm, +/−18.5° at SSD=370.5cm, and +/−19.5° at SSD=300cm. Ionization chamber measurements comparing the original treatment spread (+/−14.5°) and the optimized angle pair (+/−17.5°) at SSD=441cm showed no significant deviation (r=0.999) in percent depth dose curves, and chamber measurements from nine locations within the field showed an improvement in dose uniformity from 24.41% to 9.75%. Ionization chamber measurements correlated strongly (r=0.981) with Cherenkov intensity measured concurrently on the flat Plastic Water phantom. Patient images and TLD results also showed modest uniformity improvements. Conclusion: A decreasing linear relationship between optimal angle spread and SSD was observed. Cherenkov imaging offers a new method of rapidly analyzing and optimizing TSEBT setup

  14. Ten years of intraoperative floppy iris syndrome in the era of α-blockers

    Science.gov (United States)

    Mohamad Al-Ali, Badereddin; Radmayr, Christian; Weber, Maria; Horninger, Wolfgang; Findl, Oliver; Plas, Eugen

    2017-01-01

    Introduction The use of alpha-1 receptor antagonists in the treatment of benign prostatic hyperplasia (BPH) has created a problem in ophthalmic surgery, the so-called intraoperative floppy iris syndrome (IFIS). This consists of a billowing iris, insufficient pupillary dilation with progressive intraoperative miosis, and protrusion of iris tissue through the tunnel and side port incision that are made for access to the anterior chamber during surgery. IFIS presents particular difficulties in cataract surgery which is carried out through the pupil with manipulations in the immediate vicinity of the iris. The complications range from poor visibility of the operative field to iris damage with the surgical instruments and to rupture of the posterior capsule, with loss of lens material into the vitreous body. Material and methods A comprehensive literature review was performed using MEDLINE with MeSH terms and keywords ‘benign prostatic hyperplasia’, ‘intraoperative floppy iris syndrome’, ‘adrenergic alpha-antagonist’ and ‘cataract surgery’. In addition, reference lists from identified publications were reviewed to identify reports and studies of interest from 2001 to 2017. Results The A total of 95% of experienced ophthalmologic surgeons reported that systematic treatment with tamsulosin represents a challenging surgical condition increasing the risk of complications. Alpha-blockers are commonly prescribed, with 1,079,505 packages of tamsulosin prescribed each month in 2014 in Austria. Dose modification may be one way to reduce the risk of IFIS. A lower incidence of IFIS was reported in patients on tamsulosin in Japan, but the recommended dosage was lower than that used in Europe and the US (0.2 mg vs. 0.4 mg). Conclusions We showed that not all patients taking tamsulosin experience IFIS. Moreover, larger investigations with a prospective design are needed, including studies to monitor the pre- and post-therapeutic ophthalmologic changes under tamsulosin

  15. Long-Term Outcome and Toxicities of Intraoperative Radiotherapy for High-Risk Neuroblastoma

    International Nuclear Information System (INIS)

    Gillis, Amy M.; Sutton, Elizabeth; DeWitt, Kelly D.; Matthay, Katherine K.; Weinberg, Vivian; Fisch, Benjamin M.; Chan, Albert; Gooding, Charles; Daldrup-Link, Heike; Wara, William M.; Farmer, Diana L.; Harrison, Michael R.; Haas-Kogan, Daphne

    2007-01-01

    Purpose: To review a historical cohort of consecutively accrued patients with high-risk neuroblastoma treated with intraoperative radiotherapy (IORT) to determine the therapeutic effect and late complications of this treatment. Methods and Materials: Between 1986 and 2002, 31 patients with newly diagnosed high-risk neuroblastoma were treated with IORT as part of multimodality therapy. Their medical records were reviewed to determine the outcome and complications. Kaplan-Meier probability estimates of local control, progression-free survival, and overall survival at 36 months after diagnosis were recorded. Results: Intraoperative radiotherapy to the primary site and associated lymph nodes achieved excellent local control at a median follow-up of 44 months. The 3-year estimate of the local recurrence rate was 15%, less than that of most previously published series. Only 1 of 22 patients who had undergone gross total resection developed recurrence at the primary tumor site. The 3-year estimate of local control, progression-free survival, and overall survival was 85%, 47%, and 60%, respectively. Side effects attributable to either the disease process or multimodality treatment were observed in 7 patients who developed either hypertension or vascular stenosis. These late complications resulted in the death of 2 patients. Conclusions: Intraoperative radiotherapy at the time of primary resection offers effective local control in patients with high-risk neuroblastoma. Compared with historical controls, IORT achieved comparable control and survival rates while avoiding many side effects associated with external beam radiotherapy in young children. Although complications were observed, additional analysis is needed to determine the relative contributions of the disease process and specific components of the multimodality treatment to these adverse events

  16. Intraoperative monitoring technician: a new member of the surgical team.

    Science.gov (