  1. Radiotherapy for ocular lesions by electron beam therapy

    International Nuclear Information System (INIS)

    Miyaishi, Kazuo

    1981-01-01

    Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The appliance of conventional X ray therapy has been gradually abandaned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973; It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, 4000 - 5000 rads in total is applied by 8 MeV electron twice a week method. 3) For orbitar lymphoid neoplasm, Cobalt-60 γ ray or Linac X ray is applied together with electron beam. 4) For embryonal rhabdomyosarcoma, adenoid cystic cancer etc., the therapy for whole body is necessary. 5) For benign tumors, a small dose at a time is applied for a long time. (author)

  2. Clinical experience with routine diode dosimetry for electron beam radiotherapy

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Fontenla, Doracy P.; Vikram, Bhadrasain

    2000-01-01

    Purpose: Electron beam radiotherapy is frequently administered based on clinical setups without formal treatment planning. We felt, therefore, that it was important to monitor electron beam treatments by in vivo dosimetry to prevent errors in treatment delivery. In this study, we present our clinical experience with patient dose verification using electron diodes and quantitatively assess the dose perturbations caused by the diodes during electron beam radiotherapy. Methods and Materials: A commercial diode dosimeter was used for the in vivo dose measurements. During patient dosimetry, the patients were set up as usual by the therapists. Before treatment, a diode was placed on the patient's skin surface and secured with hypoallergenic tape. The patient was then treated and the diode response registered and stored in the patient radiotherapy system database via our in-house software. A customized patient in vivo dosimetry report showing patient details, expected and measured dose, and percent difference was then generated and printed for analysis and record keeping. We studied the perturbation of electron beams by diodes using film dosimetry. Beam profiles at the 90% prescription isodose depths were obtained with and without the diode on the beam central axis, for 6-20 MeV electron beams and applicator/insert sizes ranging from a 3-cm diameter circular field to a 25 x 25 cm open field. Results: In vivo dose measurements on 360 patients resulted in the following ranges of deviations from the expected dose at the various anatomic sites: Breast (222 patients) -20.3 to +23.5% (median deviation 0%); Head and Neck (63 patients) -21.5 to +14.8% (median -0.7%); Other sites (75 patients) -17.6 to +18.8% (median +0.5%). Routine diode dosimetry during the first treatment on 360 patients (460 treatment sites) resulted in 11.5% of the measurements outside our acceptable ±6% dose deviation window. Only 3.7% of the total measurements were outside ±10% dose deviation. Detailed

  3. Simultaneous optimization of photons and electrons for mixed beam radiotherapy.

    Science.gov (United States)

    Mueller, S; Fix, M K; Joosten, A; Henzen, D; Frei, D; Volken, W; Kueng, R; Aebersold, D M; Stampanoni, M F M; Manser, P

    2017-06-26

    The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.

  4. Simultaneous optimization of photons and electrons for mixed beam radiotherapy

    Science.gov (United States)

    Mueller, S.; Fix, M. K.; Joosten, A.; Henzen, D.; Frei, D.; Volken, W.; Kueng, R.; Aebersold, D. M.; Stampanoni, M. F. M.; Manser, P.

    2017-07-01

    The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.

  5. Inverse planning of energy-modulated electron beams in radiotherapy

    International Nuclear Information System (INIS)

    Gentry, John R.; Steeves, Richard; Paliwal, Bhudatt A.

    2006-01-01

    The use of megavoltage electron beams often poses a clinical challenge in that the planning target volume (PTV) is anterior to other radiosensitive structures and has variable depth. To ensure that skin as well as the deepest extent of the PTV receives the prescribed dose entails prescribing to a point beyond the depth of peak dose for a single electron energy. This causes dose inhomogeneities and heightened potential for tissue fibrosis, scarring, and possible soft tissue necrosis. Use of bolus on the skin improves the entrant dose at the cost of decreasing the therapeutic depth that can be treated. Selection of a higher energy to improve dose homogeneity results in increased dose to structures beyond the PTV, as well as enlargement of the volume receiving heightened dose. Measured electron data from a linear accelerator was used as input to create an inverse planning tool employing energy and intensity modulation using bolus (e-IMRT TM ). Using tools readily available in a radiotherapy department, the applications of energy and intensity modulation on the central axis makes it possible to remove hot spots of 115% or more over the depths clinically encountered. The e-IMRT TM algorithm enables the development of patient-specific dose distributions with user-defined positions of peak dose, range, and reduced dose to points beyond the prescription point

  6. The ESTRO-EQUAL quality assurance network for photon and electron radiotherapy beams in Germany

    International Nuclear Information System (INIS)

    Ferreira, I.H.; Dutreix, A.; Richter, J.; Bridier, A.; Chavaudra, J.; Svensson, H.

    2001-01-01

    Background: In 1998 an ESTRO Quality Assurance Network for radiotherapy (EQUAL) has been set up for 25 European countries for photon and electron beams in reference and non-reference conditions. Material and Methods: Measurements are done using LiF powder (DTL937-Philitech, France) that is processed with the PCL3 automatic reader (Fimel-PTW). The participating centers irradiate the TLDs with an absorbed dose of 2 Gy according to the clinical routine. Results: Until September 2000 EQUAL has checked 135 photon beams (including the beams rechecked) from 51 radiotherapy centers in Germany out of 86 accepted centers. The results show that 2% of the beam outputs in reference conditions and 3% of the percentage depth doses are outside the tolerance level (deviation > ± 5%). 6% of the beam output variations and of the wedge transmission factors show deviations > ± 5%. The global analysis of results shows deviations > ± 5% in at least one parameter for 18 beams out of the 135 beams checked. Five rechecked beams present one ''real dosimetric'' problem in one or more parameters, corresponding to 4% of the 114 beams for which the deviations cannot be attributed to set-up errors. - The EQUAL network has checked 89 electron beams in Germany. The results show that all beam outputs checked are within the tolerance level. The standard deviation for the beam output in reference conditions is 2.0% and 2.2% for the beam output for the others field sizes. The percentage of deviations > 3% and ≤ 5% for the reference beam output is higher for electron beams than for photon beam checks. Therefore the electron beam calibration and the TPS algorithms should be improved to increase the accuracy of the patient dosimetry for radiotherapy. (orig.) [de

  7. Response of canine esophagus to intraoperative electron beam radiotherapy

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Hoekstra, H.J.; Kinsella, T.J.; Barnes, M.; DeLuca, A.M.; Tochner, Z.; Pass, H.I.; Kranda, K.C.; Terrill, R.E.

    1988-01-01

    Tolerance of esophagus to intraoperative radiotherapy (IORT) was investigated in dogs. Thirteen adult foxhounds were subjected to right thoractomy, mobilization of the intrathoracic esophagus, and IORT to a 6 cm full-thickness esophageal segment using 9 MeV electrons at doses of 0, 2,000, or 3,000 cGy. Dogs were followed clinically and were evaluated at regular intervals after treatment with fiberoptic esophagoscopy, barium swallows, and postmortem histologic evaluations. One sham-irradiated control dog showed no abnormalities during follow-up of 24 months. Seven dogs receiving 2,000 cGy IORT showed transient mild dysphagia and mild esophagitis, but no clinically or pathologically significant complications. Five dogs receiving 3,000 cGy demonstrated severe ulcerative esophagitis within 6 weeks of treatment which progressed to chronic ulcerative esophagitis with stricture formation by 9 months following IORT. One 3,000 cGy dog died at 13 months from an esophageal perforation. On the basis of a pilot experience using 13 experimental animals, it was concluded that intact canine esophagus tolerates IORT well to doses of 2,000 cGy, but doses of 3,000 cGy pose serious and potentially lethal risks. The clinical application of IORT to the treatment of human intrathoracic neoplasms requiring esophageal irradiation should be approached with caution, particularly at doses exceeding 2,000 cGy

  8. Clinical application of intensity and energy modulated radiotherapy with photon and electron beams

    International Nuclear Information System (INIS)

    Xiangkui Mu

    2005-01-01

    In modern, advanced radiotherapy (e.g. intensity modulated photon radiotherapy, IMXT) the delivery time for each fraction becomes prolonged to 10-20 minutes compared with the conventional, commonly 2-5 minutes. The biological effect of this prolongation is not fully known. The large number of beam directions in IMXT commonly leads to a large integral dose in the patient. Electrons would reduce the integral dose but are not suitable for treating deep-seated tumour, due to their limited penetration in tissues. By combining electron and photon beams, the dose distributions may be improved compared with either used alone. One obstacle for using electron beams in clinical routine is that there is no available treatment planning systems that optimise electron beam treatments in a similar way as for IMXT. Protons have an even more pronounced dose fall-off, larger penetration depth and less penumbra widening than electrons and are therefore more suitable for advanced radiotherapy. However, proton facilities optimised for advanced radiotherapy are not commonly available. In some instances electron beams may be an acceptable surrogate. The first part of this study is an experimental in vitro study where the situation in a tumour during fractionated radiotherapy is simulated. The effect of the prolonged fraction time is compared with the predictions by radiobiological models. The second part is a treatment planning study to analyse the mixing of electron and photon beams for at complex target volume in comparison with IMXT. In the next step a research version of an electron beam optimiser was used for the improvement of treatment plans. The aim was to develop a method for translating crude energy and intensity matrices for optimised electrons into a deliverable treatment plan without destroying the dose distribution. In the final part, different methods of treating the spinal canal in medulloblastoma were explored in a treatment planning study that was evaluated with

  9. Dose distribution of chest wall electron beam radiotherapy for patients with breast cancer after radical mastectomy

    International Nuclear Information System (INIS)

    Cong Yetong; Chen Dawei; Bai Lan; Zhou Yinhang; Piao Yongfeng; Wang Xi; Qu Yaqin

    2006-01-01

    Objective: To study the dose distribution of different bolus after different energy electron beam irradiation to different chest wall radiotherapy for the patients with breast cancer. Methods: The paper simulated the dose distribution of women's left breast cancer after radical mastectomy by 6 and 9 MeV electron beam irradiation, and TLD was used to measure. Results: The dose of skin became higher and the dose of lung was less when 0.5 and 1.0 cm bolus were used on the body; with the increasing of the energy of electron beam, the high dose field became larger; and with the same energy of electron beam, the high dose field moved to surface of the body when the bolus was thicker. Conclusion: When different energy electron ray irradiates different thickness bolus, the dosage of skin surface increases and the dosage of anterior margin of lung reduces. With electron ray energy increasing, the high dosage field is widen, when the electron ray energy is identity, the high dosage field migrates to the surface after adding bolus. Using certain depth bolus may attain the therapeutical dose of target area. (authors)

  10. Electron beam radiotherapy for the management of recurrent extensive ocular surface squamous neoplasia with orbital extension

    Directory of Open Access Journals (Sweden)

    Ramesh Murthy

    2015-01-01

    Full Text Available Recurrent extensive ocular surface squamous neoplasia (OSSN with orbital invasion can be successfully managed with external radiotherapy using electrons resulting in eye and vision salvage. We report a case of right eye recurrent OSSN in an immunocompetent adult Indian male, with extensive orbital involvement. The patient had two previous surgical excisions with recurrent disease. At this stage, conventionally exenteration is considered the treatment modality. However, he was treated with 5040 cGy radiotherapy (15eV electrons resulting in complete disease regression. At the end of 3 years follow-up, the patient was disease free, maintained a vision of 20/25, with mild dry eye, well-managed with topical lubricants. Extensive OSSN with orbital invasion does not always need exenteration. External beam electron radiotherapy provides a noninvasive cure with organ and vision salvage and should be considered in extensive OSSN not amenable to simple excision biopsies. Long-term studies to evaluate the effect of radiation on such eyes are suggested.

  11. Electron beam radiotherapy for the management of recurrent extensive ocular surface squamous neoplasia with orbital extension.

    Science.gov (United States)

    Murthy, Ramesh; Gupta, Himika; Krishnatry, Rahul; Laskar, Siddhartha

    2015-08-01

    Recurrent extensive ocular surface squamous neoplasia (OSSN) with orbital invasion can be successfully managed with external radiotherapy using electrons resulting in eye and vision salvage. We report a case of right eye recurrent OSSN in an immunocompetent adult Indian male, with extensive orbital involvement. The patient had two previous surgical excisions with recurrent disease. At this stage, conventionally exenteration is considered the treatment modality. However, he was treated with 5040 cGy radiotherapy (15eV electrons) resulting in complete disease regression. At the end of 3 years follow-up, the patient was disease free, maintained a vision of 20/25, with mild dry eye, well-managed with topical lubricants. Extensive OSSN with orbital invasion does not always need exenteration. External beam electron radiotherapy provides a noninvasive cure with organ and vision salvage and should be considered in extensive OSSN not amenable to simple excision biopsies. Long-term studies to evaluate the effect of radiation on such eyes are suggested.

  12. Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, David J.; Shikhaliev, Polad M.; Matthews, Kenneth L. [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, Louisiana 70803-4001 (United States); Hogstrom, Kenneth R., E-mail: hogstrom@lsu.edu; Carver, Robert L.; Gibbons, John P. [Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, Louisiana 70809-3482 and Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, Louisiana 70803-4001 (United States); Clarke, Taylor; Henderson, Alexander; Liang, Edison P. [Physics and Astronomy Department, Rice University, 6100 Main MS-61, Houston, Texas 77005-1827 (United States)

    2015-09-15

    Purpose: The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. Methods: An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7–20 MeV) of an Elekta Infinity radiotherapy accelerator. Results: Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower

  13. Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators.

    Science.gov (United States)

    McLaughlin, David J; Hogstrom, Kenneth R; Carver, Robert L; Gibbons, John P; Shikhaliev, Polad M; Matthews, Kenneth L; Clarke, Taylor; Henderson, Alexander; Liang, Edison P

    2015-09-01

    The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7-20 MeV) of an Elekta Infinity radiotherapy accelerator. Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower energies. Energy calibration

  14. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

    Science.gov (United States)

    Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima

    2015-11-08

    The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.

  15. Utilization of thermoluminescent dosimetry in total skin electron beam radiotherapy of mycosis fungoides

    International Nuclear Information System (INIS)

    Antolak, John A.; Cundiff, Jackson H.; Ha, Chul S.

    1998-01-01

    Purpose: The purpose of this report is to discuss the utilization of thermoluminescent dosimetry (TLD) in total skin electron beam (TSEB) radiotherapy to: (a) compare patient dose distributions for similar techniques on different machines, (b) confirm beam calibration and monitor unit calculations, (c) provide data for making clinical decisions, and (d) study reasons for variations in individual dose readings. Methods and Materials: We report dosimetric results for 72 cases of mycosis fungoides, using similar irradiation techniques on two different linear accelerators. All patients were treated using a modified Stanford 6-field technique. In vivo TLD was done on all patients, and the data for all patients treated on both machines was collected into a database for analysis. Means and standard deviations (SDs) were computed for all locations. Scatter plots of doses vs. height, weight, and obesity index were generated, and correlation coefficients with these variables were computed. Results: The TLD results show that our current TSEB implementation is dosimetrically equivalent to the previous implementation, and that our beam calibration technique and monitor unit calculation is accurate. Correlations with obesity index were significant at several sites. Individual TLD results allow us to customize the boost treatment for each patient, in addition to revealing patient positioning problems and/or systematic variations in dose caused by patient variability. The data agree well with previously published TLD results for similar TSEB techniques. Conclusion: TLD is an important part of the treatment planning and quality assurance programs for TSEB, and routine use of TLD measurements for TSEB is recommended

  16. An experimental feasibility study on the use of scattering foil free beams for modulated electron radiotherapy.

    Science.gov (United States)

    Connell, T; Alexander, A; Evans, M; Seuntjens, J

    2012-06-07

    The potential benefit of using scattering foil free beams for delivery of modulated electron radiotherapy is investigated in this work. Removal of the scattering foil from the beamline showed a measured bremsstrahlung tail dose reduction just beyond R(p) by a factor of 12.2, 6.9, 7.4, 7.4 and 8.3 for 6, 9, 12, 16 and 20 MeV beams respectively for 2 × 2 cm(2) fields defined on-axis when compared to the clinical beamline. Monte Carlo simulations were matched to measured data through careful tuning of source parameters and the modification of certain accelerator components beyond the manufacturer's specifications. An accelerator model based on the clinical beamline and one with the scattering foil removed were imported into a Monte Carlo-based treatment planning system (McGill Monte Carlo Treatment Planning). A treatment planning study was conducted on a test phantom consisting of a PTV and two distal organs at risk (OAR) by comparing a plan using the clinical beamline to a plan using a scattering foil free beamline. A DVH comparison revealed that for quasi-identical target coverage, the volume of each OAR receiving a given dose was reduced, thus reducing the dose deposited in healthy tissue.

  17. Quality control of radiotherapy centres in the Slovak Republic: a dosimetry intercomparison of photon and electron beams under reference conditions

    International Nuclear Information System (INIS)

    Gomola, I.; Kralik, G.; Laginova, V.; Van Dam, J.

    2001-01-01

    The aim of this paper is a dosimetry intercomparison of photon and electron beams under reference conditions as well as quality control of radiotherapy centres in the Slovak Republic. The results obtained in the first check shows that only about 60% of beams are within the acceptance limit. The reasons of discrepancies were traced, in some cases by an on site visit of experts from the NRC, and unacceptable deviations were corrected. The results clearly demonstrate the usefulness of the external dosimetry checks performed with the mailed thermoluminescent dosimeters. Standard deviation of the distribution of the results decreased from SD=4.3% to SD=I.8% for checked photon beams and from SD=8.6% to SD=2.4% for electron beams, respectively, at the end of the project. The dosimetry audits which are performed in regular intervals significantly decreasing a possibility of mistreatment (under-dosage or over-dosage ) of patients due to wrong calibration of radiation therapy beams. In order to keep the reached level of dosimetry precision, it is necessary to establish the external audit in radiotherapy at the national level based on postal TLD dosimetry by transferring the know-how from the international program on quality assurance in radiotherapy dosimetry with the assistance of the IAEA. (authors)

  18. Intraoperative electron beam radiotherapy for previously irradiated advanced head and neck malignancies

    International Nuclear Information System (INIS)

    Nag, Subir; Schuller, David E.; Martinez-Monge, Rafael; Rodriguez-Villalba, Silvia; Grecula, John; Bauer, Constance

    1998-01-01

    Purpose: This is a retrospective review to evaluate the role of surgery and intraoperative electron beam radiotherapy (IOERT) in the treatment of patients with previously irradiated advanced head and neck cancers. Methods and Materials: Between January 1992 and March 1997, 38 patients (31 males, 7 females; median age of 62 years) with recurrent head and neck cancer were treated with maximal resection and IOERT at the Ohio State University (OSU). All had been previously treated with full-course radiotherapy (median 65.1 Gy, range 50-74.4 Gy). Twenty-nine patients (76%) had previously undergone one or more surgical procedures. After maximal surgery the tumor bed was treated with IOERT (single field in 36 patients and 2 fields in 2 patients), most commonly with 6 MeV electrons (87%). The dose administered (at 90% isodose line) was 15 Gy for close or microscopically positive margins in 34 patients and 20 Gy for gross disease in 1 patient. Further external beam radiation therapy (EBRT) was not given. Results: After a median follow-up of 30 months (range 8-39 months), 24 of the 38 patients (66%) recurred within the IOERT field. Median time to IOERT failure was 6 months (95% CI: 4.3-7.7). The 6-month, 1-, and 2-year control rates within the IOERT volume were 41%, 19%, and 13 %, respectively. Thirty of the 38 patients (79%) recurred in locoregional areas. Median time to locoregional failure was 4 months (95% CI: 3.3-4.7). The 6-month, 1-, and 2-year locoregional control rates were 33%, 11%, and 4%, respectively. Distant metastases occurred in 7 patients, 5 in association with IOERT failure and 2 with locoregional failure. Median overall survival was 7 months (95% CI: 4.7-9.3). The 6-month, 1-, 2-, and 3-year actuarial survival rates were 51%, 21%, 21%, and 8%, respectively. Major treatment-related complications occurred in 6 patients (16%). Conclusion: IOERT alone, at the dose used, is not sufficient for control of recurrent, previously irradiated head and neck cancers

  19. Influence of the electron energy and number of beams on the absorbed dose distributions in radiotherapy of deep seated targets.

    Science.gov (United States)

    Garnica-Garza, H M

    2014-12-01

    With the advent of compact laser-based electron accelerators, there has been some renewed interest on the use of such charged particles for radiotherapy purposes. Traditionally, electrons have been used for the treatment of fairly superficial lesions located at depths of no more than 4cm inside the patient, but lately it has been proposed that by using very high energy electrons, i.e. those with an energy in the order of 200-250MeV it should be possible to safely reach deeper targets. In this paper, we used a realistic patient model coupled with detailed Monte Carlo simulations of the electron transport in such a patient model to examine the characteristics of the resultant absorbed dose distributions as a function of both the electron beam energy as well as the number of beams for a particular type of treatment, namely, a prostate radiotherapy treatment. Each treatment is modeled as consisting of nine, five or three beam ports isocentrically distributed around the patient. An optimization algorithm is then applied to obtain the beam weights in each treatment plan. It is shown that for this particularly challenging case, both excellent target coverage and critical structure sparing can be obtained for energies in the order of 150MeV and for as few as three treatment ports, while significantly reducing the total energy absorbed by the patient with respect to a conventional megavoltage x-ray treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Influence of the electron energy and number of beams on the absorbed dose distributions in radiotherapy of deep seated targets

    International Nuclear Information System (INIS)

    Garnica-Garza, H.M.

    2014-01-01

    With the advent of compact laser-based electron accelerators, there has been some renewed interest on the use of such charged particles for radiotherapy purposes. Traditionally, electrons have been used for the treatment of fairly superficial lesions located at depths of no more than 4 cm inside the patient, but lately it has been proposed that by using very high energy electrons, i.e. those with an energy in the order of 200–250 MeV it should be possible to safely reach deeper targets. In this paper, we used a realistic patient model coupled with detailed Monte Carlo simulations of the electron transport in such a patient model to examine the characteristics of the resultant absorbed dose distributions as a function of both the electron beam energy as well as the number of beams for a particular type of treatment, namely, a prostate radiotherapy treatment. Each treatment is modeled as consisting of nine, five or three beam ports isocentrically distributed around the patient. An optimization algorithm is then applied to obtain the beam weights in each treatment plan. It is shown that for this particularly challenging case, both excellent target coverage and critical structure sparing can be obtained for energies in the order of 150 MeV and for as few as three treatment ports, while significantly reducing the total energy absorbed by the patient with respect to a conventional megavoltage x-ray treatment. - Highlights: • Technical requirements to be met in VHEET are established for the irradiation of prostate tumors. • Optimization of beam energy as a function of number of beams is provided. • Behavior of the non-tumor integral dose as a function of both energy and number of beams is examined

  1. Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy

    Science.gov (United States)

    Jong, W. L.; Ung, N. M.; Tiong, A. H. L.; Rosenfeld, A. B.; Wong, J. H. D.

    2018-03-01

    The aim of this study is to investigate the fundamental dosimetric characteristics of the MOSkin detector for megavoltage electron beam dosimetry. The reproducibility, linearity, energy dependence, dose rate dependence, depth dose measurement, output factor measurement, and surface dose measurement under megavoltage electron beam were tested. The MOSkin detector showed excellent reproducibility (>98%) and linearity (R2= 1.00) up to 2000 cGy for 4-20 MeV electron beams. The MOSkin detector also showed minimal dose rate dependence (within ±3%) and energy dependence (within ±2%) over the clinical range of electron beams, except for an energy dependence at 4 MeV electron beam. An energy dependence correction factor of 1.075 is needed when the MOSkin detector is used for 4 MeV electron beam. The output factors measured by the MOSkin detector were within ±2% compared to those measured with the EBT3 film and CC13 chamber. The measured depth doses using the MOSkin detector agreed with those measured using the CC13 chamber, except at the build-up region due to the dose volume averaging effect of the CC13 chamber. For surface dose measurements, MOSkin measurements were in agreement within ±3% to those measured using EBT3 film. Measurements using the MOSkin detector were also compared to electron dose calculation algorithms namely the GGPB and eMC algorithms. Both algorithms were in agreement with measurements to within ±2% and ±4% for output factor (except for the 4 × 4 cm2 field size) and surface dose, respectively. With the uncertainties taken into account, the MOSkin detector was found to be a suitable detector for dose measurement under megavoltage electron beam. This has been demonstrated in the in vivo skin dose measurement on patients during electron boost to the breast tumour bed.

  2. Electron beam radiotherapy for the management of recurrent extensive ocular surface squamous neoplasia with orbital extension

    OpenAIRE

    Ramesh Murthy; Himika Gupta; Rahul Krishnatry; Siddhartha Laskar

    2015-01-01

    Recurrent extensive ocular surface squamous neoplasia (OSSN) with orbital invasion can be successfully managed with external radiotherapy using electrons resulting in eye and vision salvage. We report a case of right eye recurrent OSSN in an immunocompetent adult Indian male, with extensive orbital involvement. The patient had two previous surgical excisions with recurrent disease. At this stage, conventionally exenteration is considered the treatment modality. However, he was treated with 50...

  3. Microplanar beams for radiotherapy

    International Nuclear Information System (INIS)

    Company, F.Z.; Allen, B.J.

    1996-01-01

    Recent advances in synchrotron generated X-ray beams with high fluence rate permit the investigation of the application of an array of closely spaced, parallel or converging microbeams in radiotherapy. The proposed technique takes advantage of the hypothesised repair mechanism of capillary cells between alternate microbeam zones, which replaces the lethally irradiated endothelial cells. In this study using the Monte Carlo method, the lateral and depth dose of a single planar microbeam of 100 keV in a tissue/lung/tissue phantom is investigated. Poster 195. (author)

  4. Long-term results of intraoperative electron beam radiotherapy for primary and recurrent retroperitoneal soft tissue sarcoma

    International Nuclear Information System (INIS)

    Gieschen, Holger L.; Spiro, Ira J.; Suit, Herman D.; Ott, Mark J.; Rattner, David W.; Ancukiewicz, Marek; Willett, Christopher G.

    2001-01-01

    Purpose: This study assesses the long-term outcome of patients with retroperitoneal sarcoma treated by preoperative external beam radiotherapy, resection, and intraoperative electron beam radiation (IOERT). Methods and Materials: From 1980 to 1996, 37 patients were treated with curative intent for primary or recurrent retroperitoneal soft tissue sarcoma. All patients underwent external beam radiotherapy with a median dose of 45 Gy. This was followed by laparotomy, resection, and IOERT, if feasible. Twenty patients received 10-20 Gy of IOERT with 9-15 MeV electrons. These patients were compared to a group of 17 patients receiving preoperative irradiation without IOERT. Results: The 5-yr actuarial overall survival (OS), disease-free survival, local control (LC), and freedom from distant disease of all 37 patients was 50%, 38%, 59%, and 54%, respectively. After preoperative irradiation, 29 patients (78%) underwent gross total resection. For 16 patients undergoing gross total resection and IOERT, OS and LC were 74% and 83%, respectively. In contrast, these results were less satisfactory for 13 patients undergoing gross total resection without IOERT. For these patients, OS and LC were 30% and 61%, respectively. Four patients experienced treatment-related morbidity. Conclusions: In selected patients, IOERT results in excellent local control and disease-free survival with acceptable morbidity

  5. Advanced Electron Beam Ion Sources (EBIS) for 2-nd generation carbon radiotherapy facilities

    CERN Document Server

    Shornikov, A.

    2016-01-01

    In this work we analyze how advanced Electron Beam Ion Sources (EBIS) can facilitate the progress of carbon therapy facilities. We will demonstrate that advanced ion sources enable operation of 2-nd generation ion beam therapy (IBT) accelerators. These new accelerator concepts with designs dedicated to IBT provide beams better suited for therapy and, are more cost efficient than contemporary IBT facilities. We will give a sort overview of the existing new IBT concepts and focus on those where ion source technology is the limiting factor. We will analyse whether this limitation can be overcome in the near future thanks to ongoing EBIS development.

  6. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  7. Project and construction of energy degrading and scattering plates for electron beam radiotherapy for skin diseases

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva

    2010-01-01

    There are many radiosensitive epidermotropics diseases such as mycosis fungo-ids and the syndrome of Sezary, coetaneous neoplasics originated from type T lymphocytes. Several studies indicate the eradication of the disease when treated with linear accelerators emitting electron beams with energies between 4 to 10 MeV. However, this treatment technique presents innumerable technical challenges since the disease in general reaches all patient's body, becoming necessary not only a very large field size radiation beam, but also deliver superficial doses limited to the skin depth. To reach the uniformity in the dose distribution, many techniques had already been developed. Based on these previous studies and guided by the report no. 23 of the American Association of Physicists in Medi-cine (AAPM), the present study developed an energy scattering and degrading plates and made dosimetry (computational and experimental), supplying subsidies for a future installation of Total Skin Electron Therapy (TSET) at the Servico de Radioterapia do Hospital das Clinicas de Sao Paulo. As part of the plates design, first of all, the energy spectrum of the 6 MeV electron beam of the VARIAN 2100C accelerator was reconstructed through Monte Carlo simulations using the MCNP4C code and based on experimental data. Once the spectrum is built, several materials were analyzed for the plates design based on radial and axial dose distribution, production of rays-x and dose attenuation. The simulation results were validated by experimental measurements in order to obtain a large field of radiation with 200 cm x 80 cm that meets the specifications of the AAPM protocol. (author)

  8. Intraoperative radiotherapy electron boost followed by moderate doses of external beam radiotherapy in resected soft-tissue sarcoma of the extremities

    International Nuclear Information System (INIS)

    Azinovic, Ignacio; Martinez Monge, Rafael; Aristu, Jose Javier; Salgado, Esteban; Villafranca, Elena; Hidalgo, Oscar Fernandez; Amillo, Santiago; San Julian, Miguel; Villas, Carlos; Aramendia, Jose Manuel; Calvo, Felipe A.

    2003-01-01

    Purpose: To analyze the patterns of failure and the toxicity profile of intraoperative electron beam radiotherapy (IOERT) after resection of soft tissue sarcomas of the extremities (STS). Patients and methods: Forty-five patients with extremity STS were treated with IOERT and moderate-dose postoperative radiotherapy (45-50 Gy). Twenty-six patients were treated for primary disease (PD) and 19 patients for an isolated recurrence (ILR). Tumor size was >5 cm (maximum diameter) in 36 patients (80%), and high-grade histology in PD patients was present in 14 patients (54%). In nine patients, IOERT was used alone, due to previous irradiation or patient refusal. Chemotherapy (neoadjuvant and/or adjuvant) was mainly given to high-grade tumors. Results: Nine patients relapsed in the extremity (20%), and 12 patients in distant sites (28%). Actuarial local control at 5 years was 88% for patients with negative/close margins and 57% for patients presenting positive margins (P=0.04). Five patients (11%) developed neuropathy associated with the treatment. Extremity preservation was achieved in 40 patients (88%). With a median follow-up of 93 months (range: 27-143 months) for the patients at risk, 25 patients remain alive (a 7-year actuarial survival rate of 75% for PD and 47% for ILR; P=0.01). Conclusions: IOERT combined with moderate doses of external beam irradiation yields high local control and extremity preservation rates in resected extremity STS. Peripheral nerves in the IOERT field are dose-limiting structures requiring a dose compromise in the IOERT component to avoid severe neurological damage

  9. Evaluation of the relative effectiveness of LiF-based TL detectors for electron radiotherapy beams over the energy range 6-20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Nahajowski, D.; Gora, E.; Rozwadowska-Bogusz, B.; Lesiak, J.; Polak, B.; Kabat, D.; Zawadzki, P. [Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Krakow Branch, Garncarska 11, 31-115 Krakow (Poland); Waligorski, M.P.R. [Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Krakow Branch, Garncarska 11, 31-115 Krakow (Poland); Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Krakow (Poland)], E-mail: z5waligo@cyf-kr.edu.pl

    2008-02-15

    We have performed systematic measurements of the efficiency, C{sub E}=/, of MTS-N (LiF:Mg,Ti) and LiB (Li{sub 2}B{sub 4}O{sub 7}:Mn,Si) thermoluminescence (TL) detectors exposed to electron radiotherapy beams of nominal energy 6, 9, 12, 16 and 20 MeV relative to Co-60 or 6 MV photon beams ( is the average TL output of a batch of detectors exposed to a given dose of photon beam radiation or to a beam of electrons of energy E). The TL detectors were sintered pellets of 4.5 mm diameter and ca. 0.8 mm thickness. Detectors were exposed in water to 2 Gy at respective energy-dependent depths d{sub max} applied in clinical dosimetry. The obtained results were re-calculated versus mean electron energy in the beam at depths d{sub max}. We found that, for clinical purposes, both types of TL detectors show no energy dependence: presented as average values over the investigated energy range, for MTS-N detectors =1.07{+-}1.1% and for LiB =1.03{+-}1.7%. Thus, while no correction is required for dose values estimated by LiB TLDs, the under-response of MTS-N detectors exposed to a beam of electrons has to be corrected by about 7%. At mean energy of electrons in therapeutic electron beams below about 5 MeV a decline in the response of both types of TL detectors is observed.

  10. Monte Carlo Simulation of Electron Beams for Radiotherapy - EGS4, MCNP4b and GEANT3 Intercomparison

    CERN Document Server

    Trindade, A; Alves, C M; Chaves, A; Lopes, C; Oliveira, C; Peralta, L

    2000-01-01

    In medical radiation physics, an increasing number of Monte Carlo codes are being used, which requires intercomparison between them to evaluated the accuracy of the simulated results against benchmark experiments. The Monte Carlo code EGS4, commonly used to simulate electron beams from medical linear accelerators, was compared with GEANT3 and MCNP4b. Intercomparison of electron energy spectra, angular and spatial distribution were carried out for the Siemens KD2 linear accelerator, at beam energies of 10 and 15 MeV for a field size of 10x10 cm2. Indirect validation was performed against electron depth doses curves and beam profiles measured in a MP3-PTW water phantom using a Markus planar chamber. Monte Carlo isodose lines were reconstructed and compared to those from commercial treatment planning systems (TPS's) and with experimental data.

  11. Electron linac design for pion radiotherapy

    International Nuclear Information System (INIS)

    Loew, G.A.; Brown, K.L.; Miller, R.H.; Walz, D.R.

    1977-03-01

    The electron linac provides a straightforward, state-of-the-art method of producing the primary beam required for a hospital-based multiport pion radiotherapy facility for cancer treatment. The accelerator and associated beam transport system described are capable of generating an electron beam of about 250 kW and delivering it alternately to one of several pion generators and treatment areas. Each pion generator, a prototype of which now exists at the Stanford W. W. Hansen Laboratory, would contain a target for the electron beam and sixty separate superconducting magnet channels which focus the pions in the patient. The considerations which enter the design of a practical linac are presented together with a possible layout of a flexible beam transport system

  12. Heavy Particle Beams in Tumor Radiotherapy

    International Nuclear Information System (INIS)

    Ayad, M.

    1999-01-01

    Using heavy particles beam in the tumor radiotherapy is advantageous to the conventional radiation with photons and electrons. One of the advantages of the heavy charged particle is the energy deposition processes which give a well defined range in tissue, a Bragg peak of ionization in the depth-dose distribution and slow scattering, while the dose to the surrounding healthy tissue in the vicinity is minimized. These processes can show the relation between the heavy particle and the conventional radiation is illustrated with respect to the depth dose and the relative dose. The usage of neutrons (Thermal or epithermal) in therapy necessitates implementation of capture material leading to the production of heavy charged particles (a-particles) as a result of the nuclear interaction in between. Experimentally it is found that 80% of the absorbed dose is mainly due to the presence of capture material

  13. Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

    International Nuclear Information System (INIS)

    Petit, Steven F.; Elmpt, Wouter J. C. van; Nijsten, Sebastiaan M. J. J. G.; Lambin, Philippe; Dekker, Andre L. A. J.

    2008-01-01

    Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The

  14. Analysis of material characteristics for the construction of energy degrading and scattering plates for electron beam skin radiotherapy

    International Nuclear Information System (INIS)

    Fonseca, Gabriel P.; Yoriyaz, Helio; Siqueira, Paulo T.D.; Antunes, Paula C.G.; Furnari, Laura; Santos, Gabriela R.

    2009-01-01

    There are many radiosensitive diseases associated to the skin such as mycosis fungoids and the syndrome of Sezary that are part of a sub-group of cutaneous diseases type T-cell lymphoma. Several studies indicate the eradication of the disease when treated with linear accelerators emitting electron beams with energies between 4 to 10 MeV. However, this treatment technique presents innumerable technical challenges since the disease in general reaches all patient's body, becoming necessary a very large field size radiation beam, and also, it should deliver superficial doses limited to the skin depth. To reach the uniformity in the dose distribution, many techniques had already been developed. Based on these previous studies and guided by the report nr. 23 of the AAPM (American Association of Physicists in Medicine), the present study will develop an energy scattering and degrading plates, supplying subsidies for a future installation for skin treatment at the - Servico de Radioterapia do Hospital das Clinicas de Sao Paulo. As part of the plates design, first of all, the energy spectrum of the 6 MeV electron beam of the VARIAN 2100C accelerator was reconstructed through Monte Carlo simulations using the MCNP4C code and based on experimental data. Once the spectrum is built the design of the plates has been performed analyzing several materials, shapes and dimensions most adequate on the basis of radial and axial dose distribution, production of rays-x and dose attenuation. The simulations will be validated with experimental measurements using copper and aluminum. (author)

  15. Monte Carlo based simulation of LIAC intraoperative radiotherapy accelerator along with beam shaper applicator

    Directory of Open Access Journals (Sweden)

    N Heidarloo

    2017-08-01

    Full Text Available Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric characteristics of the electron beam produced by LIAC intraoperative radiotherapy accelerator in conjunction with this applicator have been evaluated through Monte Carlo simulation by MCNP code. The results showed that the electron beam produced by the beam shaper applicator would have the desirable dosimetric characteristics, so that the mentioned applicator can be considered for clinical purposes. Furthermore, the good agreement between the results of simulation and practical dosimetry, confirms the applicability of Monte Carlo method in determining the dosimetric parameters of electron beam  intraoperative radiotherapy

  16. An Innovative Tool for Intraoperative Electron Beam Radiotherapy Simulation and Planning: Description and Initial Evaluation by Radiation Oncologists

    Energy Technology Data Exchange (ETDEWEB)

    Pascau, Javier, E-mail: jpascau@mce.hggm.es [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Departamento de Bioingenieria e Ingenieria Aeroespacial, Universidad Carlos III de Madrid, Madrid (Spain); Santos Miranda, Juan Antonio [Servicio de Oncologia Radioterapica, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain); Calvo, Felipe A. [Servicio de Oncologia Radioterapica, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain); Departamento de Oncologia, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Bouche, Ana; Morillo, Virgina [Consorcio Hospitalario Provincial de Castellon, Castellon (Spain); Gonzalez-San Segundo, Carmen [Servicio de Oncologia Radioterapica, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain); Ferrer, Carlos; Lopez Tarjuelo, Juan [Consorcio Hospitalario Provincial de Castellon, Castellon (Spain); and others

    2012-06-01

    Purpose: Intraoperative electron beam radiation therapy (IOERT) involves a modified strategy of conventional radiation therapy and surgery. The lack of specific planning tools limits the spread of this technique. The purpose of the present study is to describe a new simulation and planning tool and its initial evaluation by clinical users. Methods and Materials: The tool works on a preoperative computed tomography scan. A physician contours regions to be treated and protected and simulates applicator positioning, calculating isodoses and the corresponding dose-volume histograms depending on the selected electron energy. Three radiation oncologists evaluated data from 15 IOERT patients, including different tumor locations. Segmentation masks, applicator positions, and treatment parameters were compared. Results: High parameter agreement was found in the following cases: three breast and three rectal cancer, retroperitoneal sarcoma, and rectal and ovary monotopic recurrences. All radiation oncologists performed similar segmentations of tumors and high-risk areas. The average applicator position difference was 1.2 {+-} 0.95 cm. The remaining cancer sites showed higher deviations because of differences in the criteria for segmenting high-risk areas (one rectal, one pancreas) and different surgical access simulated (two rectal, one Ewing sarcoma). Conclusions: The results show that this new tool can be used to simulate IOERT cases involving different anatomic locations, and that preplanning has to be carried out with specialized surgical input.

  17. SU-D-19A-06: The Effect of Beam Parameters On Very High-Energy Electron Radiotherapy: A Planning Study

    International Nuclear Information System (INIS)

    Palma, B; Bazalova, M; Qu, B; Loo, B; Maxim, P; Hardemark, B; Hynning, E

    2014-01-01

    Purpose: We evaluated the effect of very high-energy electron (VHEE) beam parameters on the planning of a lung cancer case by means of Monte Carlo simulations. Methods: We simulated VHEE radiotherapy plans using the EGSnrc/BEAMnrc-DOSXYZnrc code. We selected a lung cancer case that was treated with 6MV photon VMAT to be planned with VHEE. We studied the effect of beam energy (80 MeV, 100 MeV, and 120 MeV), number of equidistant beams (16 or 32), and beamlets sizes (3 mm, 5 mm or 7 mm) on PTV coverage, sparing of organs at risk (OARs) and dose conformity. Inverse-planning optimization was performed in a research version of RayStation (RaySearch Laboratories AB) using identical objective functions and constraints for all VHEE plans. Results: Similar PTV coverage and dose conformity was achieved by all the VHEE plans. The 100 MeV and 120 MeV VHEE plans were equivalent amongst them and were superior to the 80 MeV plan in terms of OARs sparing. The effect of using 16 or 32 equidistant beams was a mean difference in average dose of 2.4% (0%–7.7%) between the two plans. The use of 3 mm beamlet size systematically reduced the dose to all the OARs. Based on these results we selected the 100MeV-16beams-3mm-beamlet-size plan to compare it against VMAT. The selected VHEE plan was more conformal than VMAT and improved OAR sparing (heart and trachea received 125% and 177% lower dose, respectively) especially in the low-dose region. Conclusion: We determined the VHEE beam parameters that maximized the OAR dose sparing and dose conformity of the actually delivered VMAT plan of a lung cancer case. The selected parameters could be used for the planning of other treatment sites with similar size, shape, and location. For larger targets, a larger beamlet size might be used without significantly increasing the dose. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Americas. E Hynning: Employee, RaySearch Americas. B Qu: None. B Loo Jr.: Research support, Ray

  18. Electron Beam Lithography

    Science.gov (United States)

    Harriott, Lloyd R.

    1997-04-01

    Electron beams have played a significant role in semiconductor technology for more than twenty years. Early electron beam machines used a raster scanned beam spot to write patterns in electron-sensitive polymer resist materials. The main application of electron beam lithography has been in mask making. Despite the inherently high spatial resolution and wide process margins of electron beam lithography, the writing rate for semiconductor wafers has been too slow to be economically viable on a large scale. In the late 1970's, variable shape electron beam writing was developed, projecting a rectangular beam whose size can be varied for each "shot" exposure of a particular pattern, allowing some integrated circuits to be made economically where a variety of "customized" patterns are desired. In the cell or block projection electron beam exposure technique, a unit cell of a repetitive pattern is projected repeatedly to increase the level of parallelism. This can work well for highly repetitive patterns such as memory chips but is not well suited to complex varying patterns such as microprocessors. The rapid progress in the performance of integrated circuits has been largely driven by progress in optical lithography, through improvements in lens design and fabrication as well as the use of shorter wavelengths for the exposure radiation. Due to limitations from the opacity of lens and mask materials, it is unlikely that conventional optical printing methods can be used at wavelengths below 193 nm or feature sizes much below 180 nm. One candidate technology for a post-optical era is the Scattering with Angular Limitation Projection Electron-beam Lithography (SCALPEL) approach, which combines the high resolution and wide process latitude inherent in electron beam lithography with the throughput of a parallel projection system. A mask consisting of a low atomic number membrane and a high atomic number pattern layer is uniformly illuminated with high energy (100 ke

  19. External beam radiotherapy for rectal adenocarcinoma

    International Nuclear Information System (INIS)

    Taylor, R.E.; Kerr, G.R.; Arnott, S.J.

    1987-01-01

    A series of 243 patients with adenocarcinoma of the rectum treated with radiotherapy is presented. Radiotherapy was combined with 5-fluorouracil, or given alone. Seventy-four patients were treated with radical external beam radiotherapy for recurrent or inoperable rectal adenocarcinoma. One hundred and forty-five patients with advanced pelvic tumours or metastases were treated with palliative pelvic radiotherapy. Twenty-four patients with small-volume residual pelvic tumour or who were felt to be at high risk of pelvic recurrence following radical resection received postoperative radiotherapy. Complete tumour regression was seen in 38% of radically treated patients, and 24% of palliatively treated patients. Partial regression was observed in 56% of radically treated patients, and 58% of palliatively treated patients. Long-term local tumour control was more commonly observed for small tumours (< 5 cm diameter). Fifty-eight % of patients treated with postoperative radiotherapy remained free of local recurrence. Survival was significantly better with small tumours. The addition of 5FU did not appear to improve survival or tumour control. (author)

  20. Guide for External Beam Radiotherapy. Procedures 2007

    International Nuclear Information System (INIS)

    Ardiet, Jean-Michel; Bourhis, Jean; Eschwege, Francois; Gerard, Jean-Pierre; Martin, Philippe; Mazeron, Jean-Jacques; Barillot, Isabelle; Bey, Pierre; Cosset, Jean-Marc; Thomas, Olivier; Bolla, Michel; Bourguignon, Michel; Godet, Jean-Luc; Krembel, David; Valero, Marc; Bara, Christine; Beauvais-March, Helene; Derreumaux, Sylvie; Vidal, Jean-Pierre; Drouard, Jean; Sarrazin, Thierry; Lindecker-Cournil, Valerie; Robin, Sun Hee Lee; Thevenet, Nicolas; Depenweiller, Christian; Le Tallec, Philippe; Ortholan, Cecile; Aimone, Nicole; Baldeschi, Carine; Cantelli, Andree; Estivalet, Stephane; Le Prince, Cyrille; QUERO, Laurent; Costa, Andre; Gerard, Jean-Pierre; Ardiet, Jean-Michel; Bensadoun, Rene-Jean; Bourhis, Jean; Calais, Gilles; Lartigau, Eric; Ginot, Aurelie; Girard, Nicolas; Mornex, Francoise; Bolla, Michel; Chauvet, Bruno; Maingon, Philippe; Martin, Etienne; Azria, David; Gerard, Jean-Pierre; Grehange, Gilles; Hennequin, Christophe; Peiffert, Didier; Toledano, Alain; Belkacemi, Yazid; Courdi, Adel; Belliere, Aurelie; Peignaux, Karine; Mahe, Marc; Bondiau, Pierre-Yves; Kantor, Guy; Lepechoux, Cecile; Carrie, Christian; Claude, Line

    2007-01-01

    In order to optimize quality and security in the delivery of radiation treatment, the French SFRO (Societe francaise de radiotherapie oncologique) is publishing a Guide for Radiotherapy. This guide is realized according to the HAS (Haute Autorite de sante) methodology of 'structured experts consensus'. This document is made of two parts: a general description of external beam radiation therapy and chapters describing the technical procedures of the main tumors to be irradiated (24). For each procedure, a special attention is given to dose constraints in the organs at risk. This guide will be regularly updated

  1. MO-FG-303-06: Evaluation of the Performance of Very High-Energy Electron (VHEE) Beams in Radiotherapy: Five Clinical Cases

    International Nuclear Information System (INIS)

    Palma, B; Bazalova-Carter, M; Qu, B; Loo, B; Maxim, P; Hardemark, B; Hynning, E

    2015-01-01

    Purpose: To evaluate the performance of 100–120 MeV very-high energy electron (VHEE) scanning pencil beams to radiotherapy by means of Monte Carlo (MC) simulations. Methods: We selected five clinical cases with target sizes of 1.2 cm 3 to 990.4 cm 3 . We calculated VHEE treatment plans using the MC EGSnrc code implemented in a MATLAB-based graphical user interface developed by our group. We generated phase space data for beam energies: 100 and 120 MeV and pencil beam spot sizes of 1, 3, and 5 mm at FWHM. The number of equidistant beams considered in this work was 16 or 32. Dose was calculated and then imported into a research version of RayStation where treatment plan optimization was performed. We compared the VHEE plans with the clinically delivered volumetric modulated arc therapy (VMAT) plan to evaluate VHEE plans performance. Results: VHEE plans provided the same PTV coverage and dose homogeneity than VMAT plans for all the cases. In average, the mean dose to organs at risk (OARs) was 24% lower for the VHEE plans. The structures that benefited the most from using VHEE were: large bowel for the esophagus case, chest wall for the liver case, brainstem for the acoustic case, carina for the lung case, and genitalia for the anal case, with 23.7–34.6% lower dose. VHEE dose distributions were more conformal than VMAT solution as confirmed by conformity indices CI100 and CI50. Integral dose to the body was in average 19.6% (9.2%–36.5%) lower for the VHEE plans. Conclusion: We have shown that VHEE plans resulted in similar or superior dose distributions compared to clinical VMAT plans for five different cases and a wide range of target volumes, including a case with a small target (1.2 cm 3 ), which represents a challenge for VMAT planning and might require the use of more complex non-coplanar VMAT plans. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Laboratories AB. E Hynning: Employee, RaySearch Laboratories AB. B Qu: None. B Loo Jr

  2. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  3. Electron beam curing paint

    International Nuclear Information System (INIS)

    Maruyama, Tsutomu

    1991-04-01

    Electron beam curing (EBC) type paint is paint that is specially prepared so that it can be cured and dried by electron beam irradiation. Electron beam irradiation achieves hardly any curing and drying of ordinary normal-temperature drying type paint or heat-drying type paint. The main type of paint in which an electron beam produces a curing reaction is one in which a radical polymerization reaction takes place under irradiation. The use of this EBC painting - drying system has been considered for a variety of fields since it has a number of special features such as the fact that the paint dries instantaneously, no heat is applied and no solvent is used. (Author)

  4. [External beam radiotherapy cone beam-computed tomography-based dose calculation].

    Science.gov (United States)

    Barateau, A; Céleste, M; Lafond, C; Henry, O; Couespel, S; Simon, A; Acosta, O; de Crevoisier, R; Périchon, N

    2018-02-01

    In external beam radiotherapy, the dose planning is currently based on computed tomography (CT) images. A relation between Hounsfield numbers and electron densities (or mass densities) is necessary for dose calculation taking heterogeneities into account. In image-guided radiotherapy process, the cone beam CT is classically used for tissue visualization and registration. Cone beam CT for dose calculation is also attractive in dose reporting/monitoring perspectives and particularly in a context of dose-guided adaptive radiotherapy. The accuracy of cone beam CT-based dose calculation is limited by image characteristics such as quality, Hounsfield numbers consistency and restrictive sizes of volume acquisition. The analysis of the literature identifies three kinds of strategies for cone beam CT-based dose calculation: establishment of Hounsfield numbers versus densities curves, density override to regions of interest, and deformable registration between CT and cone beam CT images. Literature results show that discrepancies between the reference CT-based dose calculation and the cone beam CT-based dose calculation are often lower than 3%, regardless of the method. However, they can also reach 10% with unsuitable method. Even if the accuracy of the cone beam CT-based dose calculation is independent of the method, some strategies are promising but need improvements in the automating process for a routine implementation. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  5. Scattered radiation from applicators in clinical electron beams.

    NARCIS (Netherlands)

    Battum, L.J. van; Zee, W. van der; Huizenga, H.

    2003-01-01

    In radiotherapy with high-energy (4-25 MeV) electron beams, scattered radiation from the electron applicator influences the dose distribution in the patient. In most currently available treatment planning systems for radiotherapy this component is not explicitly included and handled only by a slight

  6. Electron beam transport

    International Nuclear Information System (INIS)

    Rudjak, Yu.V.; Vladyko, V.B.

    1993-01-01

    The electron beam transport in ion channel has been investigated. The influence of the external longitudinal magnetic field and self beam magnetic field on the charge neutralization process was defined. Beam head erosion under channel is curved or the availability of transverse external magnetic field was numerically simulated. The numerical investigation of the ion-hose instability was performed. The conditions, when as a result of ion-hose instability development may be coming out of the channel by beam tail, were founded. It was shown, that supplementary creation of plasma by electron beam and ions did not lead to the reduction of ion-hose instability. Sufficient slowing down of ion-hose instability development could be achieved if betatron length increased to impulse tail. In the case of a weak initial nonsymmetrical perturbation, sausage instability was investigated. Numerical simulation showed that this instability could lead to beam radius increasing in order. The electron beam guiding by low conductive plasma channel was considered. The attractive force of beam to this channel under nonsymmetrical injection was defined analytically

  7. Proton beam radiotherapy of iris melanoma

    International Nuclear Information System (INIS)

    Damato, Bertil; Kacperek, Andrzej; Chopra, Mona; Sheen, Martin A.; Campbell, Ian R.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on outcomes after proton beam radiotherapy of iris melanoma. Methods and Materials: Between 1993 and 2004, 88 patients with iris melanoma received proton beam radiotherapy, with 53.1 Gy in 4 fractions. Results: The patients had a mean age of 52 years and a median follow-up of 2.7 years. The tumors had a median diameter of 4.3 mm, involving more than 2 clock hours of iris in 32% of patients and more than 2 hours of angle in 27%. The ciliary body was involved in 20%. Cataract was present in 13 patients before treatment and subsequently developed in another 18. Cataract had a 4-year rate of 63% and by Cox analysis was related to age (p = 0.05), initial visual loss (p < 0.0001), iris involvement (p < 0.0001), and tumor thickness (p < 0.0001). Glaucoma was present before treatment in 13 patients and developed after treatment in another 3. Three eyes were enucleated, all because of recurrence, which had an actuarial 4-year rate of 3.3% (95% CI 0-8.0%). Conclusions: Proton beam radiotherapy of iris melanoma is well tolerated, the main problems being radiation-cataract, which was treatable, and preexisting glaucoma, which in several patients was difficult to control

  8. The short and long term effects of intraoperative electron beam radiotherapy (IORT) on thoracic organs after pneumonectomy an experimental study in the canine model

    NARCIS (Netherlands)

    de Boer, Willem; Mehta, DM; Timens, W; Hoekstra, HJ

    1999-01-01

    Purpose: The tolerance of mediastinal structures and thoracic organs to intraoperative radiotherapy (IORT) was investigated in the canine model. Methods and Materials: Twenty-two adult beagles divided into three groups were subjected to a left pneumonectomy and IORT (10 MeV electrons) at doses of 20

  9. Local recurrence rates in breast cancer patients treated with intraoperative electron-boost radiotherapy versus postoperative external-beam electron-boost irradiation. A sequential intervention study

    International Nuclear Information System (INIS)

    Reitsamer, R.; Menzel, C.; Peintinger, F.; Kopp, M.; Kogelnik, H.D.; Sedlmayer, F.

    2004-01-01

    Background and purpose: the purpose of this sequential intervention study was to determine the rate of local recurrences and the rate of distant metastases in patients with invasive breast cancer who had been treated with breast-conserving surgery and postoperative radiation therapy to the whole breast either with postoperative electron boost in group 1 or with intraoperative electron boost (IORT) in group 2. Patients and methods: after breast-conserving surgery, 378 women with invasive breast cancer of tumor sizes T1 and T2 received 51-56.1 gy of postoperative radiation therapy to the whole breast in 1.7-gy fractions. 188 of those patients additionally received a postoperative electron boost of 12 gy in group 1 from January 1996 to October 1998. Consecutively, from October 1998 to March 2001, 190 patients received intraoperative electron-boost radiotherapy of 9 gy to the tumor bed in group 2. The groups were comparable with regard to age, menopausal status, tumor size, grading, and nodal status. All statistical tests were two-sided. Results: during a median follow-up period of 55.3 months in group 1 and 25.8 months in group 2, local recurrences were observed in eight of 188 patients (4.3%) in group 1, and no local recurrence was seen in group 2 (p = 0.082). Distant metastases occurred in 15 of the 188 patients (7.9%) in group 1 and in two of the 190 patients (1.1%) in group 2 (p = 0.09). The 4-year actuarial rates of local recurrence were 4.3% (95% confidence interval, 1.8-8.2%) and 0.0% (95% confidence interval, 0.0-1.9%) and the 4-year actuarial rates of distant metastases were 7.9% (95% confidence interval, 4.5-12.8%) and 1.1% (95% confidence interval, 0.1-3.8%). Conclusion: immediate IORT boost yielded excellent local control figures in this prospective investigation and appears to be superior to conventional postoperative boost in a short-term follow-up. (orig.)

  10. FMECA Application to Intraoperative Electron Beam Radiotherapy Procedure As a Quality Method to Prevent and Reduce Patient’s Risk in Conservative Surgery for Breast Cancer

    Directory of Open Access Journals (Sweden)

    Cristiana Vidali

    2017-08-01

    Full Text Available IntroductionFailure Mode Effects and Criticalities Analysis (FMECA represents a prospective method for risk assessment in complex medical practices. Our objective was to describe the application of FMECA approach to intraoperative electron beam radiotherapy (IOERT, delivered using a mobile linear accelerator, for the treatment of early breast cancer as an anticipated boost.Materials and methodsA multidisciplinary Working Group, including several different professional profiles, was created before the beginning of clinical practice in 2012, with the purpose of writing the Flow Chart and applying the FMECA methodology to IOERT procedure. Several criticalities were identified a priori in the different steps of the procedure and a list of all potential failure modes (FMs was drafted and ranked using the risk priority number (RPN scoring system, based on the product of three parameters: severity, occurrence, and detectability (score between 1 and 5. The actions aimed at reducing the risk were then defined by the Working Group and the risk analysis was repeated in 2014 and in 2016, in order to assess the improvement achieved.ResultsFifty-one FMs were identified, which represented the issues prospectively investigated according to the FMECA methodology. Considering a set threshold of 30, the evaluated RPNs show that 33 out of 51 FMs are critical; 6 are included in the moderate risk class (RPN: 31–40; 16 in the intermediate risk class (RPN: 41–50, and 11 in the high risk class (RPN: >50.DiscussionThe most critical steps concerned the surgical procedure and IOERT set-up. The introduction of the corrective actions into the clinical practice achieved the reduction of the RPNs in the re-analysis of the FMECA worksheet after 2 and 4 years, respectively.ConclusionFMECA proved to be a useful tool for prospective evaluation of potential failures in IOERT and contributed to optimize patient safety and to improve risk management culture among all the

  11. Electron Beam Ion Sources

    CERN Document Server

    Zschornacka, G.; Thorn, A.

    2013-12-16

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviolet, visible light) from highly charged ions. This chapter gives an overview of EBIS physics, the principle of operation, and the known technical solutions. Using examples, the performance of EBISs as well as their applications in various fields of basic research, technology and medicine are discussed.

  12. Study of LiF:Mg,Ti and CaSO4:Dy dosimeters TL response to electron beams of 6 MeV applied to radiotherapy using PMMA and solid water phantoms

    International Nuclear Information System (INIS)

    Bravim, A.; Sakuraba, R.K.; Cruz, J.C.; Campos, L.L.

    2011-01-01

    The performance of CaSO 4 :Dy and LiF:Mg,Ti dosimeters to electron beams applied to radiotherapy was investigated. The TL response of these dosimeters was studied for 6 MeV electron beams using PMMA and Solid Water (SW) phantoms. The dosimeters were previously separated in groups according to their TL individual sensitivities to 60 Co gamma-radiation in air under electronic equilibrium conditions. After that, they were irradiated with 6 MeV electron doses of 0.1, 0.5, 1, 5 and 10 Gy using a linear accelerator Clinac 2100C Varian of Hospital Israelita Albert Einstein – HIAE. The electron beam irradiations were performed using a 10 × 10 cm 2 field size, 100 cm source-phantom surface distance and the dosimeters were positioned at the depth of maximum dose (1.2 cm). The TL readings were carried out between 24 and 32 h after irradiation using a Harshaw 3500 TL reader. The TL dose–response of both type of dosimeters and phantoms presented linear behavior on the electron dose range from 0.1 to 5 Gy CaSO 4 :Dy dosimeter is 21 times more sensitive than LiF:Mg,Ti, dosimeter commonly used in clinical dosimetry. The obtained results indicate that the performance of CaSO 4 :Dy dosimeters is similar to LiF:Mg,Ti dosimeters and this material can be an alternative dosimetric material to be used to clinical electron beams dosimetry.

  13. On beam quality and flatness of radiotherapy megavoltage photon beams

    International Nuclear Information System (INIS)

    Hossain, Murshed; Rhoades, Jeffrey

    2016-01-01

    Ratio of percentage depth dose (PDD) at two depths, PDD at a depth of 10 cm (PDD 10 ), and beam flatness are monitored regularly for radiotherapy beams for quality assurance. The purpose of this study is to understand the effects of changes in one of these parameters on the other. Is it possible to monitor only the beam flatness and not PDD? The investigation has two components. Naturally occurring i.e., unintended changes in PDD ratio and in-plane flatness for 6 and 10 MV photon beams for one particular Siemens Artiste Linac are monitored for a period of about 4 years. Secondly, deliberate changes in the beam parameters are induced by changing the bending magnet current (BMI). Relationships between various beam parameters for unintended changes as well as deliberate changes are characterized. Long term unintentional changes of PDD ratio are found to have no systematic trend. The flatness in the in plane direction for 6 and 10 MV beams show slow increase of 0.43 and 0.75 % respectively in about 4 years while the changes in the PDD ratio show no such trend. Over 10 % changes in BMI are required to induce changes in the beam quality indices at 2 % level. PDD ratio for the 10 MV beam is found to be less sensitive, while the depth of maximum dose, d max , is more sensitive to the changes in BMI compared to the 6 MV beam. Tolerances are more stringent for PDD 10 than PDD ratio for the 10 MV beam. PDD ratio, PDD 10 , and flatness must be monitored independently. Furthermore, off axis ratio alone cannot be used to monitor flatness. The effect of beam quality change in the absolute dose is clinically insignificant.

  14. Electron beam processing system

    International Nuclear Information System (INIS)

    Kashiwagi, Masayuki

    2004-01-01

    Electron beam Processing Systems (EPS) are used as useful and powerful tools in many industrial application fields such as the production of cross-linked wire, rubber tire, heat shrinkable film and tubing, curing, degradation of polymers, sterilization and environmental application. In this paper, the feature and application fields, the selection of machine ratings and safety measures of EPS will be described. (author)

  15. Electron Beam Generation in Tevatron Electron Lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  16. Electron beam generation in Tevatron electron lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  17. Electron beams in radiation therapy

    International Nuclear Information System (INIS)

    Bruinvis, I.A.D.

    1987-01-01

    Clinical electron beams in interaction with beam flattening and collimating devices are studied, in order to obtain the means for adequate electron therapy. A treatment planning method for arbitrary field shapes is developed that takes the properties of the collimated electron beams into account. An electron multiple-scattering model is extended to incorporate a model for the loss of electrons with depth, in order to improve electron beam dose planning. A study of ionisation measurements in two different phantom materials yields correction factors for electron beam dosimetry. (Auth.)

  18. The physics of radiotherapy X-rays and electrons

    CERN Document Server

    Metcalfe, Peter; Hoban, Peter

    2012-01-01

    The Physics of Radiotherapy X-Rays and Electrons is an updated successor to The Physics of Radiotherapy X-Rays from Linear Accelerators published in 1997. This new volume includes a significant amount of new material, including new chapters on electrons in radiotherapy and IMRT, IGRT, and tomotherapy, which have become key developments in radiation therapy. Also updated from the earlier edition are the physics beam modeling chapters, including Monte Carlo methods, adding those mysterious electrons, as well as discourse on radiobiological modeling including TCP, NTCP, and EUD and the impact of these concepts on plan analysis and inverse planning. This book is intended as a standard reference text for postgraduate radiation oncology medical physics students. It will also be of interest to radiation oncology registrars and residents, dosimetrists, and radiation therapists. The new text contains review questions at the end of each chapter and full bibliographic entries. Fully indexed. Selected questions and ans...

  19. Relativistic electron beam device

    Science.gov (United States)

    Freeman, J.R.; Poukey, J.W.; Shope, S.L.; Yonas, G.

    1975-07-01

    A design is given for an electron beam device for irradiating spherical hydrogen isotope bearing targets. The accelerator, which includes hollow cathodes facing each other, injects an anode plasma between the cathodes and produces an approximately 10 nanosecond, megajoule pulse between the anode plasma and the cathodes. Targets may be repetitively positioned within the plasma between the cathodes, and accelerator diode arrangement permits materials to survive operation in a fusion power source. (auth)

  20. Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer

    NARCIS (Netherlands)

    Canters, R.A.M.; Lips, I.M.; Wendling, M.; Kusters, M.; Zeeland, M. van; Gerritsen, R.M.; Poortmans, P.; Verhoef, C.G.

    2016-01-01

    BACKGROUND AND PURPOSE: Creating an individualized tissue equivalent material build-up (i.e. bolus) for electron beam radiation therapy is complex and highly labour-intensive. We implemented a new clinical workflow in which 3D printing technology is used to create the bolus. MATERIAL AND METHODS: A

  1. Comparison of measurements of absorbed dose to water using a water calorimeter and ionization chambers for clinical radiotherapy photon and electron beams

    International Nuclear Information System (INIS)

    Marles, A.E.M.

    1981-01-01

    With the development of the water calorimeter direct measurement of absorbed dose in water becomes possible. This could lead to the establishment of an absorbed dose rather than an exposure related standard for ionization chambers for high energy electrons and photons. In changing to an absorbed dose standard it is necessary to investigate the effect of different parameters, among which are the energy dependence, the air volume, wall thickness and material of the chamber. The effect of these parameters is experimentally studied and presented for several commercially available chambers and one experimental chamber, for photons up to 25 MV and electrons up to 20 MeV, using a water calorimeter as the absorbed dose standard and the most recent formalism to calculate the absorbed dose with ion chambers. For electron beams, the dose measured with the calorimeter was 1% lower than the dose calculated with the chambers, independent of beam energy and chamber. For photon beams, the absorbed dose measured with the calorimeter was 3.8% higher than the absorbed dose calculated from the chamber readings. Such differences were found to be chamber and energy independent. The results for the photons were found to be statistically different from the results with the electron beams. Such difference could not be attributed to a difference in the calorimeter response

  2. Depressed collector for electron beams

    Science.gov (United States)

    Ives, R. Lawrence (Inventor)

    2005-01-01

    A depressed collector for recovery of spent beam energy from electromagnetic sources emitting sheet or large aspect ration annular electron beams operating aver a broad range of beam voltages and currents. The collector incorporates a trap for capturing and preventing the return of reflected and secondary electrons.

  3. Model of contamination sources of electron for radiotherapy of beams of photons; Modelo de fuentes de contaminacion de electrones para radioterapia de haces de fotones

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Infantes, W.; Lallena Rojo, A. M.; Anguiano Millan, M.

    2013-07-01

    Proposes a model of virtual sources of electrons, that allows to reproduce the sources to the input parameters of the representation of the patient. To compare performance in depth values and calculated profiles from the full simulation of the heads, with the calculated values using sources model, found that the model is capable of playing depth dose distributions and profiles. (Author)

  4. Device for electron beam machining

    International Nuclear Information System (INIS)

    Panzer, S.; Ardenne, T. von; Liebergeld, H.

    1984-01-01

    The invention concerns a device for electron beam machining, in particular welding. It is aimed at continuous operation of the electron irradiation device. This is achieved by combining the electron gun with a beam guiding chamber, to which vacuum chambers are connected. The working parts to be welded can be arranged in the latter

  5. Electron beam-cured coating

    International Nuclear Information System (INIS)

    Kishi, Naoyuki

    1976-01-01

    The method for hardening coatings by the irradiation with electron beams is reviewed. The report is divided into seven parts, namely 1) general description and characteristics of electron beam-cured coating, 2) radiation sources of curing, 3) hardening conditions and reaction behaviour, 4) uses and advantages, 5) latest trends of the industry, 6) practice in the field of construction materials, and 7) economy. The primary characteristics of the electron beam hardening is that graft reaction takes place between base resin and coating to produce strong adhesive coating without any pretreatment. A variety of base resins are developed. High class esters of acrylic acid monomers and methacrylic acid monomers are mainly used as dilutants recently. At present, scanning type accelerators are used, but the practical application of the system producing electron beam of curtain type is expected. The dose rate dependence, the repetitive irradiation and the irradiation atmosphere are briefly described. The filed patent applications on the electron beam hardening were analyzed by the officer of Japan Patent Agency. The production lines for coatings by the electron beam hardening in the world are listed. In the electron beam-cured coating, fifty percent of given energy is consumed effectively for the electron beam hardening, and the solvents discharged from ovens and polluting atmosphere are not used, because the paints of high solid type is used. The running costs of the electron beam process are one sixth of the thermal oven process. (Iwakiri, K.)

  6. Estimation of the dose deposited by electron beams in radiotherapy in voxelised phantoms using the Monte Carlo simulation platform GATE based on GEANT4 in a grid environment

    International Nuclear Information System (INIS)

    Perrot, Y.

    2011-01-01

    Radiation therapy treatment planning requires accurate determination of absorbed dose in the patient. Monte Carlo simulation is the most accurate method for solving the transport problem of particles in matter. This thesis is the first study dealing with the validation of the Monte Carlo simulation platform GATE (GEANT4 Application for Tomographic Emission), based on GEANT4 (Geometry And Tracking) libraries, for the computation of absorbed dose deposited by electron beams. This thesis aims at demonstrating that GATE/GEANT4 calculations are able to reach treatment planning requirements in situations where analytical algorithms are not satisfactory. The goal is to prove that GATE/GEANT4 is useful for treatment planning using electrons and competes with well validated Monte Carlo codes. This is demonstrated by the simulations with GATE/GEANT4 of realistic electron beams and electron sources used for external radiation therapy or targeted radiation therapy. The computed absorbed dose distributions are in agreement with experimental measurements and/or calculations from other Monte Carlo codes. Furthermore, guidelines are proposed to fix the physics parameters of the GATE/GEANT4 simulations in order to ensure the accuracy of absorbed dose calculations according to radiation therapy requirements. (author)

  7. Computer simulation of electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Sabchevski, S.P.; Mladenov, G.M. (Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. po Elektronika)

    1994-04-14

    Self-fields and forces as well as the local degree of space-charge neutralization in overcompensated electron beams are considered. The radial variation of the local degree of space-charge neutralization is analysed. A novel model which describes the equilibrium potential distribution in overcompensated beams is proposed and a method for computer simulation of the beam propagation is described. Results from numerical experiments which illustrate the propagation of finite emittance overneutralized beams are presented. (Author).

  8. Novel electron beam recording media

    International Nuclear Information System (INIS)

    1974-01-01

    Electron beam recording media comprise a film of an olefin-SO 2 copolymer on a support. Certain of these copolymers give direct print-out relief patterns after exposure to electron beams. The chemical composition and preparation of these layered films is described

  9. Introduction to electron beam processing

    International Nuclear Information System (INIS)

    Waichiro Kawakami

    1994-01-01

    The contents are general features in the irradiation of polymers, electron beam machines - low energy, medium energy, high energy; application of EB machine in industries, engineering of EB processing, dosimetry of EB (electron beam) safe operation of EB machine, recent topics on EB processing under development. 3 tabs., 4 figs., 17 refs

  10. Treatment of basal cell epithelioma with high energy electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Y. (Hyogo-ken Cancer Center, Kobe (Japan)); Kumano, M.; Kumano, K.

    1981-11-01

    Thirty patients with basal cell epithelioma received high energy electron beam therapy. They were irradiated with a dose ranging from 4,800 rad (24 fractions, 35 days) to 12,000 rad (40 fractions, 57 days). Tumors disappeared in all cases. These were no disease-related deaths; in one patient there was recurrence after 2 years. We conclude that radiotherapy with high energy electron beam is very effective in the treatment of basal cell epithelioma.

  11. Dynamic electron arc radiotherapy (DEAR): a feasibility study

    International Nuclear Information System (INIS)

    Rodrigues, Anna; Yin, Fang-Fang; Wu, Qiuwen

    2014-01-01

    Compared to other radiation therapy modalities, clinical electron beam therapy has remained practically unchanged for the past few decades even though electron beams with multiple energies are widely available on most linacs. In this paper, we present the concept of dynamic electron arc radiotherapy (DEAR), a new conformal electron therapy technique with synchronized couch motion. DEAR utilizes combination of gantry rotation, couch motion, and dose rate modulation to achieve desirable dose distributions in patient. The electron applicator is kept to minimize scatter and maintain narrow penumbra. The couch motion is synchronized with the gantry rotation to avoid collision between patient and the electron cone. In this study, we investigate the feasibility of DEAR delivery and demonstrate the potential of DEAR to improve dose distributions on simple cylindrical phantoms. DEAR was delivered on Varian's TrueBeam linac in Research Mode. In conjunction with the recorded trajectory log files, mechanical motion accuracies and dose rate modulation precision were analyzed. Experimental and calculated dose distributions were investigated for different energies (6 and 9 MeV) and cut-out sizes (1×10 cm 2  and 3×10 cm 2  for a 15×15 cm 2  applicator). Our findings show that DEAR delivery is feasible and has the potential to deliver radiation dose with high accuracy (root mean square error, or RMSE of <0.1 MU, <0.1° gantry, and <0.1 cm couch positions) and good dose rate precision (1.6 MU min −1 ). Dose homogeneity within ±2% in large and curved targets can be achieved while maintaining penumbra comparable to a standard electron beam on a flat surface. Further, DEAR does not require fabrication of patient-specific shields. These benefits make DEAR a promising technique for conformal radiotherapy of superficial tumors. (paper)

  12. Physical properties of charged particle beams for use in radiotherapy

    International Nuclear Information System (INIS)

    Knapp, E.A.

    1975-01-01

    The physical properties of the possible charged particle beams used for cancer radiotherapy are reviewed. Each property is discussed for all interesting particles (π, p, α, Ne ion) and the differences are emphasized. This is followed by a short discussion of the several beam delivery systems used in particle therapy today, emphasizing the differences in the problems for the several different radiations, particularly the differences between the accelerated particle beams and those of a secondary nature. Dose calculation techniques are described

  13. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  14. Three-Dimensional Electron Beam Dose Calculations.

    Science.gov (United States)

    Shiu, Almon Sowchee

    The MDAH pencil-beam algorithm developed by Hogstrom et al (1981) has been widely used in clinics for electron beam dose calculations for radiotherapy treatment planning. The primary objective of this research was to address several deficiencies of that algorithm and to develop an enhanced version. Two enhancements have been incorporated into the pencil-beam algorithm; one models fluence rather than planar fluence, and the other models the bremsstrahlung dose using measured beam data. Comparisons of the resulting calculated dose distributions with measured dose distributions for several test phantoms have been made. From these results it is concluded (1) that the fluence-based algorithm is more accurate to use for the dose calculation in an inhomogeneous slab phantom, and (2) the fluence-based calculation provides only a limited improvement to the accuracy the calculated dose in the region just downstream of the lateral edge of an inhomogeneity. The source of the latter inaccuracy is believed primarily due to assumptions made in the pencil beam's modeling of the complex phantom or patient geometry. A pencil-beam redefinition model was developed for the calculation of electron beam dose distributions in three dimensions. The primary aim of this redefinition model was to solve the dosimetry problem presented by deep inhomogeneities, which was the major deficiency of the enhanced version of the MDAH pencil-beam algorithm. The pencil-beam redefinition model is based on the theory of electron transport by redefining the pencil beams at each layer of the medium. The unique approach of this model is that all the physical parameters of a given pencil beam are characterized for multiple energy bins. Comparisons of the calculated dose distributions with measured dose distributions for a homogeneous water phantom and for phantoms with deep inhomogeneities have been made. From these results it is concluded that the redefinition algorithm is superior to the conventional

  15. Libera Electron Beam Position Processor

    CERN Document Server

    Ursic, Rok

    2005-01-01

    Libera is a product family delivering unprecedented possibilities for either building powerful single station solutions or architecting complex feedback systems in the field of accelerator instrumentation and controls. This paper presents functionality and field performance of its first member, the electron beam position processor. It offers superior performance with multiple measurement channels delivering simultaneously position measurements in digital format with MHz kHz and Hz bandwidths. This all-in-one product, facilitating pulsed and CW measurements, is much more than simply a high performance beam position measuring device delivering micrometer level reproducibility with sub-micrometer resolution. Rich connectivity options and innate processing power make it a powerful feedback building block. By interconnecting multiple Libera electron beam position processors one can build a low-latency high throughput orbit feedback system without adding additional hardware. Libera electron beam position processor ...

  16. TECHNOLOGIES FOR DELIVERY OF PROTON AND ION BEAMS FOR RADIOTHERAPY

    CERN Document Server

    Owen, H; Alonso, J; Mackay, R

    2014-01-01

    Recent developments for the delivery of proton and ion beam therapy have been significant, and a number of technological solutions now exist for the creation and utilisation of these particles for the treatment of cancer. In this paper we review the historical development of particle accelerators used for external beam radiotherapy and discuss the more recent progress towards more capable and cost-effective sources of particles.

  17. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  18. Low voltage electron beam accelerators

    International Nuclear Information System (INIS)

    Ochi, Masafumi

    2003-01-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  19. Electron beam micromachining of plastics

    Czech Academy of Sciences Publication Activity Database

    Dupák, Libor

    2014-01-01

    Roč. 49, 5-6 (2014), s. 310-314 ISSN 0861-4717 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA MŠk EE.2.3.20.0103 Institutional support: RVO:68081731 Keywords : micromachining of plastics * Electron beam Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  20. Relativistic electron beams above thunderclouds

    DEFF Research Database (Denmark)

    Füellekrug, M.; Roussel-Dupre, R.; Symbalisty, E. M. D.

    2011-01-01

    of electrons partially discharge the lightning electric field above thunderclouds and thereby gain a mean energy of similar to 7MeV to transport a total charge of similar to-10mC upwards. The impulsive current similar to 3 x 10(-3) Am-2 associated with relativistic electron beams above thunderclouds...

  1. Electron beam processing of polymers

    International Nuclear Information System (INIS)

    Silva, Leonardo G. Andrade e; Dias, Djalma B.; Calvo, Wilson A.P.; Miranda, Leila F. de

    2011-01-01

    The aim of this work is the use of electron beam produced by industrial electron accelerators to process polymers. There are several applications, such as, irradiation of wires and electric cables for automotive, aerospace, household appliance, naval and computing industries. The effect of different radiation doses in low density polyethylene (LDPE) was also studied. After irradiation and crosslinking it was thermally expanded forming LDPE foam. In addition, poly(N-vinyl-2-pyrrolidone) (PVP) hydrogels using electron beam processing were prepared. In all cases studied crosslinking percentages of the samples were determined. (author)

  2. Polarized electron beams at SLAC

    International Nuclear Information System (INIS)

    Moffeit, K.C.

    1992-11-01

    SLAC has successfully accelerated high energy polarized electrons for the Stanford Linear Collider and fixed polarized nuclear target experiments. The polarized electron beams at SLAC use a gallium arsenide (GaAlAs for E-142) photon emission source to provide the beam of polarized electrons with polarization of approximately 28% (41% for E-142). While the beam emittance is reduced in the damping ring for SLC operation a system of bend magnets and superconducting solenoids preserve and orient the spin direction for maximum longitudinal polarization at the collision point. The electron polarization is monitored with a Compton scattering polarimeter, and was typically 22% at the e+e- collision point for the 1992 run. Improvements are discussed to increase the source polarization and to reduce the depolarization effects between the source and the collision point

  3. Electron beam fusion targets

    International Nuclear Information System (INIS)

    Clauser, M.J.; Sweeney, M.A.

    1975-01-01

    R The behavior of the DT filled gold shells when irradiated by a variety of pulse shapes was studied. In these pulses the power (and beam current) was varied, but the voltage was kept constant at 1 MeV. In general the performance of the target, for a given peak power, was not significantly affected by the pulse shape. Pulses with rise times of up to half the implosion time do not significantly degrade the target performance. The use of the ''optimal pulse'' of laser fusion with a fixed peak power does not appear to improve the performance of these targets. The main function of the ''optimal pulse'' is to produce a large rho r of the target during the thermonuclear burn. In e-beam targets a total rho r of 5--10 g/cm 2 can be obtained without pulse shaping; the problem here is one of achieving high enough temperatures to ignite the DT. (U.S.)

  4. METHOD OF ELECTRON BEAM PROCESSING

    DEFF Research Database (Denmark)

    2003-01-01

    As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which is the o......As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which...... is the option of welding workpieces of large thicknesses. Therefore the idea is to guide the electron beam (2) to the workpiece via a hollow wire, said wire thereby acting as a prolongation of the vacuum chamber (4) down to workpiece. Thus, a workpiece need not be placed inside the vacuum chamber, thereby...... exploiting the potential of electron beam processing to a greater degree than previously possible, for example by means of electron beam welding...

  5. Plural beam electron gun assembly

    International Nuclear Information System (INIS)

    Stratton, M.G.

    1977-01-01

    The invention relates to a cathode ray tube plural-beam-in-line bi-potential electron gun assembly, having applied beam currents of differing levels, manifests structurally modified gun structures to effect focused beam landings at the screen that are evidenced as substantially equi-sized spots thereby providing improved resolution and brightness of the screen imagery. The structural changes embody modifications of the related focusing and accelerator electrodes of the respective guns to provide a partial telescoping arrangement for effecting the discrete placement, forming and shielding of the final focusing lenses. The three lenses so formed are in different planes in partial overlapping axial relationship

  6. Characterization of a homemade ionization chamber for radiotherapy beams

    Energy Technology Data Exchange (ETDEWEB)

    Neves, Lucio P., E-mail: lpneves@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Perini, Ana P., E-mail: aperini@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Santos, Gelson P. dos, E-mail: gpsantos@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Xavier, Marcos, E-mail: mxavier@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.br [Universidade Federal de Pernambuco, Departamento de Energia Nuclear, Av. Prof. Luiz Freire 1000, 50740-540 Recife (Brazil); Caldas, Linda V.E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo (Brazil)

    2012-07-15

    A homemade cylindrical ionization chamber was studied for routine use in therapy beams of {sup 60}Co and X-rays. Several characterization tests were performed: leakage current, saturation, ion collection efficiency, polarity effect, stability, stabilization time, chamber orientation and energy dependence. All results obtained were within international recommendations. Therefore the homemade ionization chamber presents usefulness for routine dosimetric procedures in radiotherapy beams. - Highlights: Black-Right-Pointing-Pointer A homemade ionization chamber was studied for routine use in radiotherapy. Black-Right-Pointing-Pointer Several characterization tests were performed and the results were satisfactory. Black-Right-Pointing-Pointer This chamber was compared to commercial ones and the results were similar. Black-Right-Pointing-Pointer This chamber is suitable for calibration procedures in {sup 60}Co beams.

  7. Bilateral Rhegmatogenous Retinal Detachment during External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Takako Hidaka

    2016-06-01

    Full Text Available Herein, we report a case of nontraumatic bilateral rhegmatogenous retinal detachment (RRD during external beam radiotherapy for nonocular tumor, presented as an observational case study in conjunction with a review of the relevant literature. A 65-year-old male was referred to our hospital due to bilateral RRD. He underwent a biopsy for a tumor of the left frontal lobe 4 months prior to presentation, and the tumor had been diagnosed as primary central nerve system B-cell type lymphoma. He received chemotherapy and external beam radiotherapy for 1 month. There were no traumatic episodes. Bilateral retinal detachment occurred during a series of radiotherapies. Simultaneous nontraumatic bilateral retinal detachment is rare. The effects of radiotherapy on ocular functionality, particularly in cases involving retinal adhesion and vitreous contraction, may include RRD. Thus, it is necessary to closely monitor the eyes of patients undergoing radiotherapy, particularly those undergoing surgery for retinal detachment and those with a history of photocoagulation for retinal tears, a relevant family history, or risk factors known to be associated with RRD.

  8. Characterization of an Electron Gun for Hollow Electron Beam Collimation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Siqi [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2012-08-01

    Hollow electron beam collimation (HEBC) is a new technique developed to complement conventional beam collimation system to remove beam halo in a controlled fashion. We study the characteristics of the electron gun that produces the hollow electron beam. Cathode yield and beam profile measurements are used to extract information on gun performance. Results of characteristic measurements are presented.

  9. A review of electron beam dose calculation algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Kell, P.A. [Royal Adelaide Hospital, SA (Australia)]|[Adelaide Univ., SA (Australia). Dept. of Mathematical Physics; Hoban, P.W. [Prince of Wales Hospital, Randwick, NSW (Australia)

    1996-09-01

    The advantage of accurate dose calculation in radiotherapy is the availability of better quality information with which to prescribe treatments, and also increased confidence when optimisation procedures are applied in the planning process. Due to the continual increase in computation speed through improvements in technology, a number of advanced electron beam dose calculation algorithms have recently been developed which incorporate physically rigorous modelling of the scattering and interaction processes involved in electron transport. These algorithms are significantly more accurate than those employed by commercially available radiotherapy planning systems. The advantages and disadvantages of various calculation methods are discussed and reviewed. These include the 3D Pencil beam method, the Pencil Beam Redefinition Method, the Multi-ray model, theoretical perturbative methods, the Phase Space Evolution model, Monte Carlo techniques, the Superposition/Convolution method, the Macro-Monte Carlo algorithm, the Super-Monte Carlo method and the Voxel-based Monte Carlo method are discussed in this review. 120 refs., 15 figs.

  10. A review of electron beam dose calculation algorithms.

    Science.gov (United States)

    Keall, P J; Hoban, P W

    1996-09-01

    The advantage of accurate dose calculation in radiotherapy is the availability of better quality information with which to prescribe treatments, and also increased confidence when optimisation procedures are applied in the planning process. Due to the continual increase in computation speed through improvements in technology, a number of advanced electron beam dose calculation algorithms have recently been developed which incorporate physically rigorous modelling of the scattering and interaction processes involved in electron transport. These algorithms are significantly more accurate than those employed by commercially available radiotherapy planning systems. The advantages and disadvantages of the 3D Pencil beam method, the Pencil Beam Redefinition Method, the Multi-ray model, theoretical perturbative methods, the Phase Space Evolution model, Monte Carlo techniques, the Superposition/Convolution method, the Macro-Monte Carlo algorithm, the Super-Monte Carlo method and the Voxel-based Monte Carlo method are discussed in this review.

  11. Electron beam writing on semiconductors

    International Nuclear Information System (INIS)

    Bierhenke, H.; Kutzer, E.; Pascher, A.; Plitzner, H.; Rummel, P.; Siemens A.G., Muenchen; Siemens A.G., Muenchen

    1979-08-01

    Reported are the results of the 3 1/2 year research project 'Electron beam Writing on Semiconductors'. Work has been done in the field of direct wafer exposure techniques, and of mask making. Described are resist technology, setting up of a research device, exploration of alignment procedures, manufacturing of devices and their radiation influence. Furthermore, investigations and measurements of an electron beam machine bought for mask making purposes, the development of LSI-circuits with this machine, the software necessary and important developments of digital subsystems are reported. (orig.) [de

  12. Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Vincent W.C. [Department of Health Technology and Informatics, Hong Kong Polytechnic University, Kowloon, Hong Kong (Hong Kong); Yang Zhining; Zhang Wuzhe; Wu Lili [Cancer Hospital, Shantou University Medical College, Shantou (China); Lin Zhixiong, E-mail: zxlin5@yahoo.com [Cancer Hospital, Shantou University Medical College, Shantou (China)

    2012-07-01

    This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

  13. Compensation techniques in NIRS proton beam radiotherapy

    International Nuclear Information System (INIS)

    Akanuma, A.; Majima, H.; Furukawa, S.

    1982-01-01

    Proton beam has the dose distribution advantage in radiation therapy, although it has little advantage in biological effects. One of the best advantages is its sharp fall off of dose after the peak. With proton beam, therefore, the dose can be given just to cover a target volume and potentially no dose is delivered thereafter in the beam direction. To utilize this advantage, bolus techniques in conjunction with CT scanning are employed in NIRS proton beam radiation therapy planning. A patient receives CT scanning first so that the target volume can be clearly marked and the radiation direction and fixation method can be determined. At the same time bolus dimensions are calculated. The bolus frames are made with dental paraffin sheets according to the dimensions. The paraffin frame is replaced with dental resin. Alginate (a dental impression material with favorable physical density and skin surface contact) is now employed for the bolus material. With fixation device and bolus on, which are constructed individually, the patient receives CT scanning again prior to a proton beam treatment in order to prove the devices are suitable. Alginate has to be poured into the frame right before each treatments. Further investigations are required to find better bolus materials and easier construction methods

  14. Compensation techniques in NIRS proton beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Akanuma, A. (Univ. of Tokyo, Japan); Majima, H.; Furukawa, S.

    1982-09-01

    Proton beam has the dose distribution advantage in radiation therapy, although it has little advantage in biological effects. One of the best advantages is its sharp fall off of dose after the peak. With proton beam, therefore, the dose can be given just to cover a target volume and potentially no dose is delivered thereafter in the beam direction. To utilize this advantage, bolus techniques in conjunction with CT scanning are employed in NIRS proton beam radiation therapy planning. A patient receives CT scanning first so that the target volume can be clearly marked and the radiation direction and fixation method can be determined. At the same time bolus dimensions are calculated. The bolus frames are made with dental paraffin sheets according to the dimensions. The paraffin frame is replaced with dental resin. Alginate (a dental impression material with favorable physical density and skin surface contact) is now employed for the bolus material. With fixation device and bolus on, which are constructed individually, the patient receives CT scanning again prior to a proton beam treatment in order to prove the devices are suitable. Alginate has to be poured into the frame right before each treatments. Further investigations are required to find better bolus materials and easier construction methods.

  15. Industrial applications of electron beam

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1997-01-01

    The review of industrial applications with use of electron beams has been done. Especially the radiation technologies being developed in Poland have been shown. Industrial installations with electron accelerators as radiation source have been applied for: modification of polymers; modification of thyristors; sterilization of health care materials; radiopreservation of food and other consumer products; purification of combustion flue gases in heat and power plants. 14 refs, 6 tabs, 7 figs

  16. Electron beam solenoid reactor concept

    International Nuclear Information System (INIS)

    Bailey, V.; Benford, J.; Cooper, R.; Dakin, D.; Ecker, B.; Lopez, O.; Putman, S.; Young, T.S.T.

    1977-01-01

    The electron Beam Heated Solenoid (EBHS) reactor is a linear magnetically confined fusion device in which the bulk or all of the heating is provided by a relativistic electron beam (REB). The high efficiency and established technology of the REB generator and the ability to vary the coupling length make this heating technique compatible with several radial and axial enery loss reduction options including multiple-mirrors, electrostatic and gas end-plug techniques. This paper addresses several of the fundamental technical issues and provides a current evaluation of the concept. The enhanced confinement of the high energy plasma ions due to nonadiabatic scattering in the multiple mirror geometry indicates the possibility of reactors of the 150 to 300 meter length operating at temperatures > 10 keV. A 275 meter EBHS reactor with a plasma Q of 11.3 requiring 33 MJ of beam eneergy is presented

  17. Olfactory neural tumours - the role of external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Slevin, N.J.; Irwin, C.J.R.; Banerjee, S.S.; Path, F.R.C.; Gupta, N.K.; Farrington, W.T. [Christie Hospital and Holt Radium Inst., Manchester (United Kingdom)

    1996-11-01

    Olfactory neuroblastoma is an uncommon tumour arising in the nasal cavity or paranasal sinuses. We report the management of nine cases treated with external beam radiotherapy subsequent to surgery, either attempted definitive removal or biopsy only. Recent refinements in pathological evaluation of these tumours are discussed. Seven cases were deemed classical olfactory neuroblastoma whilst two were classified as neuroendocrine carcinoma. The clinical features, radiotherapy technique and variable natural history are presented. Seven of eight patients treated radically were controlled locally, with a minimum follow-up of two years. Three patients developed cervical lymph node disease and three patients died of systemic metastatic disease. Suggestions are made as to which patients should have en-bloc resection rather than definitive radiotherapy. (author).

  18. Free-electron laser beam

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    2003-01-01

    The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7μm FEL beam. Cancer cells are considered diagnosed by FEL beam of far-infrared-THz range. The FEL beam CT is expected to have a wide variety of application without the radiation exposure and its resolution is equal or superior to that of usual imaging techniques. (N.I.)

  19. NLC electron injector beam dynamics

    International Nuclear Information System (INIS)

    Yeremian, A.D.; Miller, R.H.

    1995-10-01

    The Next Linear Collider (NLC) being designed at SLAC requires a train of 90 electron bunches 1.4 ns apart at 120 Hz. The intensity and emittance required at the interaction point, and the various machine systems between the injector and the IP determine the beam requirements from the injector. The style of injector chosen for the NLC is driven by the fact that the production of polarized electrons at the IP is a must. Based on the successful operation of the SLC polarized electron source a similar type of injector with a DC gun and subharmonic bunching system is chosen for the NLC

  20. Beam Dynamics With Electron Cooling

    CERN Document Server

    Uesugi, T; Noda, K; Shibuya, S; Syresin, E M

    2004-01-01

    Electron cooling experiments have been carried out at HIMAC in order to develop new technologies in heavy-ion therapy and related researches. The cool-stacking method, in particular, has been studied to increase the intensity of heavy-ions. The maximum stack intensity was 2 mA, above which a fast ion losses occurred simulatneously with the vertical coherent oscillations. The instability depends on the working point, the stacked ion-density and the electron-beam density. The instability was suppressed by reducing the peak ion-density with RF-knockout heating.

  1. Electron beam control for barely separated beams

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method for achieving independent control of multiple beams in close proximity to one another, such as in a multi-pass accelerator where coaxial beams are at different energies, but moving on a common axis, and need to be split into spatially separated beams for efficient recirculation transport. The method for independent control includes placing a magnet arrangement in the path of the barely separated beams with the magnet arrangement including at least two multipole magnets spaced closely together and having a multipole distribution including at least one odd multipole and one even multipole. The magnetic fields are then tuned to cancel out for a first of the barely separated beams to allow independent control of the second beam with common magnets. The magnetic fields may be tuned to cancel out either the dipole component or tuned to cancel out the quadrupole component in order to independently control the separate beams.

  2. Image-guided radiotherapy in near real time with intensity-modulated radiotherapy megavoltage treatment beam imaging.

    Science.gov (United States)

    Mao, Weihua; Hsu, Annie; Riaz, Nadeem; Lee, Louis; Wiersma, Rodney; Luxton, Gary; King, Christopher; Xing, Lei; Solberg, Timothy

    2009-10-01

    To utilize image-guided radiotherapy (IGRT) in near real time by obtaining and evaluating the online positions of implanted fiducials from continuous electronic portal imaging device (EPID) imaging of prostate intensity-modulated radiotherapy (IMRT) delivery. Upon initial setup using two orthogonal images, the three-dimensional (3D) positions of all implanted fiducial markers are obtained, and their expected two-dimensional (2D) locations in the beam's-eye-view (BEV) projection are calculated for each treatment field. During IMRT beam delivery, EPID images of the megavoltage treatment beam are acquired in cine mode and subsequently analyzed to locate 2D locations of fiducials in the BEV. Simultaneously, 3D positions are estimated according to the current EPID image, information from the setup portal images, and images acquired at other gantry angles (the completed treatment fields). The measured 2D and 3D positions of each fiducial are compared with their expected 2D and 3D setup positions, respectively. Any displacements larger than a predefined tolerance may cause the treatment system to suspend the beam delivery and direct the therapists to reposition the patient. Phantom studies indicate that the accuracy of 2D BEV and 3D tracking are better than 1 mm and 1.4 mm, respectively. A total of 7330 images from prostate treatments were acquired and analyzed, showing a maximum 2D displacement of 6.7 mm and a maximum 3D displacement of 6.9 mm over 34 fractions. This EPID-based, real-time IGRT method can be implemented on any external beam machine with portal imaging capabilities without purchasing any additional equipment, and there is no extra dose delivered to the patient.

  3. The international protocol for the dosimetry of external radiotherapy beams based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    Andreo, P.

    2001-01-01

    An International Code of Practice (CoP, or dosimetry protocol) for external beam radiotherapy dosimetry based on standards of absorbed dose to water has been published by the IAEA on behalf of IAEA, WHO, PAHO and ESTRO. The CoP provides a systematic and internationally unified approach for the determination of the absorbed dose to water in reference conditions with radiotherapy beams. The development of absorbed-dose-to-water standards for high-energy photons and electrons offers the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. Many laboratories already provide calibrations at the radiation quality of 60Co gamma-rays and some have extended calibrations to high-energy photon and electron beams. The dosimetry of kilovoltage x-rays, as well as that of proton and ion beams can also be based on these standards. Thus, a coherent dosimetry system based on the same formalism is achieved for practically all radiotherapy beams. The practical use of the CoP as simple. The document is formed by a set of different CoPs for each radiation type, which include detailed procedures and worksheets. All CoPs are based on ND,w chamber calibrations at a reference beam quality Qo, together with radiation beam quality correction factors kQ preferably measured directly for the user's chamber in a standards laboratory. Calculated values of kQ are provided together with their uncertainty estimates. Beam quality specifiers are 60Co, TPR20,10 (high-energy photons), R50 (electrons), HVL and kV (x-rays) and Rres (protons and ions) [es

  4. Optimization of beam orientations and beam weights for conformal radiotherapy using mixed integer programming

    Energy Technology Data Exchange (ETDEWEB)

    Wang Chuang; Dai Jianrong; Hu Yimin [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences, PO Box 2258, Beijing 100021 (China)

    2003-12-21

    An algorithm for optimizing beam orientations and beam weights for conformal radiotherapy has been developed. The algorithm models the optimization of beam orientations and beam weights as a problem of mixed integer linear programming (MILP), and optimizes the beam orientations and beam weights simultaneously. The application process of the algorithm has four steps: (a) prepare a pool of beam orientation candidates with the consideration of avoiding any patient gantry collision and avoiding direct irradiation of organs at risk with quite low tolerances (e.g., eyes). (b) Represent each beam orientation candidate with a binary variable, and each beam weight with a continuous variable. (c) Set up an optimization problem according to dose prescriptions and the maximum allowed number of beam orientations. (d) Solve the optimization problem with a ready-to-use MILP solver. After optimization, the candidates with unity binary variables remain in the final beam configuration. The performance of the algorithm was tested with clinical cases. Compared with standard treatment plans, the beam-orientation-optimized plans had better dose distributions in terms of target coverage and avoidance of critical structures. The optimization processes took less than 1 h on a PC with a Pentium IV 2.4 GHz processor.

  5. Electron beam measurements on the Daresbury SRS

    International Nuclear Information System (INIS)

    Laundy, D.; Cummings, S.

    1992-01-01

    Two experiments which use hard x-ray synchrotron radiation have been carried out to allow us to monitor the electron beam on the Daresbury SRS. The beam spatial and angular vertical position and size was determined over a period of time when the SRS was operating normally. From these measurements, the position and angular stability of the electron beam during the measurement period was assessed and correlation of the beam emittance to the electron current was determined

  6. Electron beam curing of coating

    International Nuclear Information System (INIS)

    Fujioka, S.; Fujikawa, Z.

    1974-01-01

    Electron beam curing (EBC) method, by which hardened coating film is obtained by polymerizing and cross-linking paint with electron beam, has finally reached industrialized stage. While about seven items such as short curing time, high efficiency of energy consumption, and homogeneous curing are enumerated as the advantages of EBC method, it has limitations of the isolation requirement from air needing the injection of inert gas, and considerable amount of initial investment. In the electron accelerators employed in EBC method, the accelerating voltage is 250 to 750 kV, and the tube current is several tens of mA to 200 mA. As an example of EBC applications, EBC ''Erio'' steel sheet was developed by the cooperative research of Nippon Steel Corp., Dai-Nippon Printing Co. and Toray Industries, Inc. It is a high-class pre-coated metal product made from galvanized steel sheets, and the flat sheets with cured coating are sold, and final products are fabricated by being worked in various shapes in users. It seems necessary to develop the paint which enables to raise added value by adopting the EBC method. (Wakatsuki, Y.)

  7. Dosimetry for electron beam application

    International Nuclear Information System (INIS)

    Miller, A.

    1983-12-01

    This report describes two aspects of electron beam dosimetry, on one hand development of film dosimeters and measurements of their properties, and on the other hand development of calorimeters for calibration of routine dosimeters, e.g. thin films. Two types of radiochromic thin film dosimeters have been developed in this department, and the properties of these and commercially available dosimeters have been measured and found to be comparable. Calorimeters which are in use for routine measurements, are being investigated with reference to their application as standardizing instruments, and new calorimeters are being developed. (author)

  8. Apparatus for irradiation with electron beam

    International Nuclear Information System (INIS)

    Uehara, K.; Ito, A.; Nishimune, K.; Fujita, K.

    1976-01-01

    An irradiation apparatus with high energy electrons is disclosed in which a wire shaped or linear object to be irradiated is moved back and forth many times under an electron window so as to irradiate it with an electron beam. According to one feature of the invention, an electron beam, which leaks through gaps between the objects to be irradiated or which penetrates the objects to be irradiated, is reversed by a magnetic field approximately perpendicular to the scanning face of the electron beam by means of a magnet which is disposed under the objects to be irradiated, and the reversed electron beam is thereby again applied to the objects to be irradiated. A high utilization rate of the electron beam is accomplished, and the objects can be thereby uniformly irradiated with the electron beam. 4 claims, 6 drawing figures

  9. Electron beam parallel X-ray generator

    Science.gov (United States)

    Payne, P.

    1967-01-01

    Broad X ray source produces a highly collimated beam of low energy X rays - a beam with 2 to 5 arc minutes of divergence at energies between 1 and 6 keV in less than 5 feet. The X ray beam is generated by electron bombardment of a target from a large area electron gun.

  10. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  11. Improving external beam radiotherapy by combination with internal irradiation.

    Science.gov (United States)

    Dietrich, A; Koi, L; Zöphel, K; Sihver, W; Kotzerke, J; Baumann, M; Krause, M

    2015-07-01

    The efficacy of external beam radiotherapy (EBRT) is dose dependent, but the dose that can be applied to solid tumour lesions is limited by the sensitivity of the surrounding tissue. The combination of EBRT with systemically applied radioimmunotherapy (RIT) is a promising approach to increase efficacy of radiotherapy. Toxicities of both treatment modalities of this combination of internal and external radiotherapy (CIERT) are not additive, as different organs at risk are in target. However, advantages of both single treatments are combined, for example, precise high dose delivery to the bulk tumour via standard EBRT, which can be increased by addition of RIT, and potential targeting of micrometastases by RIT. Eventually, theragnostic radionuclide pairs can be used to predict uptake of the radiotherapeutic drug prior to and during therapy and find individual patients who may benefit from this treatment. This review aims to highlight the outcome of pre-clinical studies on CIERT and resultant questions for translation into the clinic. Few clinical data are available until now and reasons as well as challenges for clinical implementation are discussed.

  12. Simultaneous optimization of beam orientations and beam weights in conformal radiotherapy

    International Nuclear Information System (INIS)

    Rowbottom, Carl Graham; Khoo, Vincent S.; Webb, Steve

    2001-01-01

    A methodology for the concurrent optimization of beam orientations and beam weights in conformal radiotherapy treatment planning has been developed and tested on a cohort of five patients. The algorithm is based on a beam-weight optimization scheme with a downhill simplex optimization engine. The use of random voxels in the dose calculation provides much of the required speed up in the optimization process, and allows the simultaneous optimization of beam orientations and beam weights in a reasonable time. In the implementation of the beam-weight optimization algorithm just 10% of the original patient voxels are used for the dose calculation and cost function evaluation. A fast simulated annealing algorithm controls the optimization of the beam arrangement. The optimization algorithm was able to produce clinically acceptable plans for the five patients in the cohort study. The algorithm equalized the dose to the optic nerves compared to the standard plans and reduced the mean dose to the brain stem by an average of 4.4% (±1.9, 1 SD), p value=0.007. The dose distribution to the PTV was not compromised by developing beam arrangements via the optimization algorithm. In conclusion, the simultaneous optimization of beam orientations and beam weights has been developed to be routinely used in a realistic time. The results of optimization in a small cohort study show that the optimization can reliably produce clinically acceptable dose distributions and may be able to improve dose distributions compared to those from a human planner

  13. Rippled beam free electron laser amplifier

    Science.gov (United States)

    Carlsten, Bruce E.

    1999-01-01

    A free electron laser amplifier provides a scalloping annular electron beam that interacts with the axial electric field of a TM.sub.0n mode. A waveguide defines an axial centerline and, a solenoid arranged about the waveguide produces an axial constant magnetic field within the waveguide. An electron beam source outputs a annular electron beam that interacts with the axial magnetic field to have an equilibrium radius and a ripple radius component having a variable radius with a ripple period along the axial centerline. An rf source outputs an axial electric field that propagates within the waveguide coaxial with the electron beam and has a radial mode that interacts at the electron beam at the equilibrium radius component of the electron beam.

  14. Method for surface treatment by electron beams

    International Nuclear Information System (INIS)

    Panzer, S.; Doehler, H.; Bartel, R.; Ardenne, T. von.

    1985-01-01

    The invention has been aimed at simplifying the technology and saving energy in modifying surfaces with the aid of electron beams. The described beam-object geometry allows to abandon additional heat treatments. It can be used for surface hardening

  15. Combined external beam and intraluminal radiotherapy for irresectable Klatskin tumors

    Energy Technology Data Exchange (ETDEWEB)

    Schleicher, U.M. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); Staatz, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Alzen, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Abt. Kinderradiologie, Giessen Univ. (Germany); Andreopoulos, D. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); BOC Oncology Centre, Nikosia (Cyprus)

    2002-12-01

    Background: In most cases of proximal cholangiocarcinoma, curative surgery is not possible. Radiotherapy can be used for palliative treatment. We report our experience with combined external beam and intraluminal radiotherapy of advanced Klatskin's tumors. Patients and Methods: 30 patients were treated for extrahepatic proximal bile duct cancer. Our schedule consisted for external beam radiotherapy (median dose 30 Gy) and a high-dose-rate brachytherapy boost (median dose 40 Gy) delivered in four or five fractions, which could be applied completely in twelve of our patients. 15 patients in the brachytherapy and nine patients in the non-brachytherapy group received additional low-dose chemotherapy with 5-fluorouracil. Results: The brachytherapy boost dose improved the effect of external beam radiotherapy by increasing survival from a median of 3.9 months in the non-brachytherapy group to 9.1 months in the brachytherapy group. The effect was obvious in patients receiving a brachytherapy dose above 30 Gy, and in those without jaundice at the beginning of radiotherapy (p<0.05). Conclusions: The poor prognosis in patients with advanced Klatskin's tumors may be improved by combination therapy, with the role of brachytherapy and chemotherapy still to be defined. Our results suggest that patients without jaundice should be offered brachytherapy, and that a full dose of more than 30 Gy should be applied. (orig.) [German] Hintergrund: Bei den meisten Patienten mit proximalen Cholangiokarzinomen ist eine kurative Operation nicht mehr moeglich. Im Rahmen der Palliativbehandlung kann die Strahlentherapie eingesetzt werden. Wir berichten ueber unsere Erfahrungen mit der Kombination aus perkutaner und intraluminaler Strahlentherapie fortgeschrittener Klatskin-Tumoren. Patienten und Methode: 30 Patienten wurden wegen extrahepatischer proximaler Gallengangskarzinome behandelt. Unser Therapieschema umfasste eine perkutane Strahlentherapie (mediane Dosis: 30 Gy) sowie einen

  16. Plasma lenses for focusing relativistic electron beams

    International Nuclear Information System (INIS)

    Govil, R.; Wheeler, S.; Leemans, W.

    1997-01-01

    The next generation of colliders require tightly focused beams with high luminosity. To focus charged particle beams for such applications, a plasma focusing scheme has been proposed. Plasma lenses can be overdense (plasma density, n p much greater than electron beam density, n b ) or underdense (n p less than 2 n b ). In overdense lenses the space-charge force of the electron beam is canceled by the plasma and the remaining magnetic force causes the electron beam to self-pinch. The focusing gradient is nonlinear, resulting in spherical aberrations. In underdense lenses, the self-forces of the electron beam cancel, allowing the plasma ions to focus the beam. Although for a given beam density, a uniform underdense lens produces smaller focusing gradients than an overdense lens, it produces better beam quality since the focusing is done by plasma ions. The underdense lens can be improved by tapering the density of the plasma for optimal focusing. The underdense lens performance can be enhanced further by producing adiabatic plasma lenses to avoid the Oide limit on spot size due to synchrotron radiation by the electron beam. The plasma lens experiment at the Beam Test Facility (BTF) is designed to study the properties of plasma lenses in both overdense and underdense regimes. In particular, important issues such as electron beam matching, time response of the lens, lens aberrations and shot-to-shot reproducibility are being investigated

  17. Experimental Device for Electron Beam Micromachining

    Czech Academy of Sciences Publication Activity Database

    Dupák, Libor; Zobač, Martin; Dupák, Jan; Vlček, Ivan

    2006-01-01

    Roč. 41, 5-6 (2006), s. 272-275 ISSN 0861-4717. [EBT 2006 - International Conference on Electron Beam Technologies /8./. Varna, 05.06.2006-10.06.2006] Institutional research plan: CEZ:AV0Z20650511 Keywords : electron beam drilling * quartz glass Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  18. Electron beam treatment of industrial wastewater

    International Nuclear Information System (INIS)

    Han, Bumsoo; Kim, JinKyu; Kim, Yuri

    2004-01-01

    For industrial wastewater with low impurity levels such as contaminated ground water, cleaning water and etc., purification only with electron beam is possible, but it should be managed carefully with reducing required irradiation doses as low as possible. Also for industrial wastewater with high impurity levels such as dyeing wastewater, leachate and etc., purification only with electron beam requires high amount of doses and far beyond economies. Electron beam treatment combined with conventional purification methods such as coagulation, biological treatment, etc. is suitable for reduction of non-biodegradable impurities in wastewater and will extend the application area of electron beam. A pilot plant with electron beam for treating 1,000 m 3 /day of wastewater from dyeing industries has constructed and operated continuously since Oct 1998. Electron beam irradiation instead of chemical treatment shows much improvement in removing impurities and increases the efficiency of biological treatment. Actual plant is under consideration based upon the experimental results. (author)

  19. Counterstreaming electron beam profile and position monitor

    International Nuclear Information System (INIS)

    Schriber, S.O.; Hohban, K.J.

    1977-01-01

    Individual profiles and positions of two counterstreaming 10 MeV electron beams were measured using the strongly forward directed bremsstrahlung radiation produced when a small fraction of the beam impinges on a tantalum foil. The 0.02 mm wide foil is driven through the electron beams by an external motor connected to the foil by a linear vacuum feedthrough. Bremsstrahlung radiation is detected by a series of ordinary semiconductor diodes spaced around the circumference of the beam vacuum pipe in two planes. The planes are on opposite sides of the foil and are equidistant and parallel to the plane of motion of the foil. The diodes produce output currents proportional to the bremsstrahlung radiation intensity and require no biasing voltages. Design and operational features of the beam monitor for electron beams up to 100 MeV are described. Measurements on counterstreaming 10 MeV pulsed electron beams are presented. Spatial resolutions of 0.3 mm are easily discernable

  20. Integrated control system for electron beam processes

    Science.gov (United States)

    Koleva, L.; Koleva, E.; Batchkova, I.; Mladenov, G.

    2018-03-01

    The ISO/IEC 62264 standard is widely used for integration of the business systems of a manufacturer with the corresponding manufacturing control systems based on hierarchical equipment models, functional data and manufacturing operations activity models. In order to achieve the integration of control systems, formal object communication models must be developed, together with manufacturing operations activity models, which coordinate the integration between different levels of control. In this article, the development of integrated control system for electron beam welding process is presented as part of a fully integrated control system of an electron beam plant, including also other additional processes: surface modification, electron beam evaporation, selective melting and electron beam diagnostics.

  1. Industrial applications of electron beam accelerators

    International Nuclear Information System (INIS)

    Braid, W.G. Jr.

    1976-01-01

    The use of electron beam accelerators for crosslinking polyolefins for shrinking food packaging is discussed. Irradiation procedures, accelerator characteristics, and industrial operations are described

  2. Electron beam sterilization for dishes

    International Nuclear Information System (INIS)

    Deren, Wang; Meizhen, Fang

    1995-01-01

    Modern biological science often needs various fine strike devices which are often made from non-toxic transparent plastic. The application of high temperature steam to the sterilization as a traditional methods often causes deformation and colour change. When chemicals are applied to the sterilization residure of chemical grain often causes toxicity. Only application of radiation to the sterilization can overcome this faults and carry out with sterility assurance at room temperature. In this research 1.3 MeV electron beam coming from Model JJ-2 accelerator was applied for sterilization to 96-well tissue culture plates. After clean packaging the plates were irradiated with 31.7 XGy and operational voltage 1.3 MeV and 100 μA on the PY device. Repeated tests demonstrate that the products are sterile. The output is 2 x 10 5 pieces for each year. (author)

  3. The use of Monte-Carlo codes for treatment planning in external-beam radiotherapy

    International Nuclear Information System (INIS)

    Alan, E.; Nahum, PhD.

    2003-01-01

    Monte Carlo simulation of radiation transport is a very powerful technique. There are basically no exact solutions to the Boltzmann transport equation. Even, the 'straightforward' situation (in radiotherapy) of an electron beam depth-dose distribution in water proves to be too difficult for analytical methods without making gross approximations such as ignoring energy-loss straggling, large-angle single scattering and Bremsstrahlung production. monte Carlo is essential when radiation is transport from one medium into another. As the particle (be it a neutron, photon, electron, proton) crosses the boundary then a new set of interaction cross-sections is simply read in and the simulation continues as though the new medium were infinite until the next boundary is encountered. Radiotherapy involves directing a beam of megavoltage x rays or electrons (occasionally protons) at a very complex object, the human body. Monte Carlo simulation has proved in valuable at many stages of the process of accurately determining the distribution of absorbed dose in the patient. Some of these applications will be reviewed here. (Rogers and al 1990; Andreo 1991; Mackie 1990). (N.C.)

  4. Optics of Electron Beam in the Recycler

    International Nuclear Information System (INIS)

    Burov, A.; Kroc, T.; Lebedev, V.; Nagaitsev, S.; Prost, L.; Pruss, S.; Shemyakin, A.; Sutherland, M.; Warner, A.; Kazakevich, G.; Tiunov, M.

    2006-01-01

    Electron cooling of 8.9 GeV/c antiprotons in the Recycler ring (Fermilab) requires high current and good quality of the DC electron beam. Electron trajectories of ∼0.2 A or higher DC electron beam have to be parallel in the cooling section, within ∼ 0.2 mrad, making the beam envelope cylindrical. These requirements yielded a specific scheme of the electron transport from a gun to the cooling section, with electrostatic acceleration and deceleration in the Pelletron. Recuperation of the DC beam limits beam losses at as tiny level as ∼0.001%, setting strict requirements on the return electron line to the Pelletron and a collector. To smooth the beam envelope in the cooling section, it has to be linear and known at the transport start. Also, strength of the relevant optic elements has to be measured with good accuracy. Beam-based optic measurements are being carried out and analysed to get this information. They include beam simulations in the Pelletron, differential optic (beam response) measurements and simulation, beam profile measurements with optical transition radiation, envelope measurements and analysis with orifice scrapers. Current results for the first half-year of commissioning are presented. Although electron cooling is already routinely used for pbar stacking, its efficiency is expected to be improved

  5. Introduction of beam flatness filter for 60Co teletherapy beam and its efficacy in clinical radiotherapy

    International Nuclear Information System (INIS)

    Sathiyan, S.; Ravichandran, R.; Ravikumar, M.

    2003-01-01

    In the western countries cobalt-60 machines have become obsolete, whereas in India we have about 250 machines operational for clinical radiotherapy. The basic differences of 6 MV x-ray beam and cobalt-60 beam are: a) build-up d max point, b) flatness of beam at depths, and c) sharpness of the beam edge. We looked at the homogeneity of delivered dose in the target volume in a 3 field SAD technique for 60 Co (80 cm, 100 cm) and 6 MV treatments. More dose variations are seen in 60 Co treated volume. The excess curvature of isodose curves of 60 Co at depths may be one of the reasons for this inhomogeneity in dose to target volume. Therefore, there is need for achieving perfect flatness in the isodose curves at desired depths. A flattening filter was fabricated using dental wax impression material to account for depths of curvature of 50% 60 Co isodose curve. The filter was fabricated for the Theratron 780C machine for necessary flatness. The beam flatness with filter was measured with a) ionization and b) TL dosimetry methods. The flattened beam profile was compared with 6 MV x-ray beam (Clinac-1800, M/s Varian, USA). Our measurements show uniform flatness of cobalt-60 isodose curve at desired depth and useful radiation field width comparable to 6 MV x-ray photon profile at full width at half maximum (FWHM). If this concept is extendable to short field widths, it appears that there is scope for use of such filter in the treatments of oesophagus, larynx, and pituitary tumours to achieve dose homogeneity. Using this flatness filter and penumbra trimmer, we may achieve better quality cobalt-60 beam for radiotherapy. (author)

  6. Breast-conserving radiation therapy using combined electron and intensity-modulated radiotherapy technique

    International Nuclear Information System (INIS)

    Li, J.G.; Williams, S.S.; Goffinet, D.R.; Boer, A.L.; Xing, L.

    2000-01-01

    An electron beam with appropriate energy was combined with four intensity modulated photon beams. The direction of the electron beam was chosen to be tilted 10-20 laterally from the anteroposterior direction. Two of the intensity-modulated photon beams had the same gantry angles as the conventional tangential fields, whereas the other two beams were rotated 15-25' toward the anteroposterior directions from the first two photon beams. An iterative algorithm was developed which optimizes the weight of the electron beam as well as the fluence profiles of the photon beams for a given patient. Two breast cancer patients with early-stage breast tumors were planned with the new technique and the results were compared with those from 3D planning using tangential fields as well as 9-field intensity-modulated radiotherapy (IMRT) techniques. The combined electron and IMRT plans showed better dose conformity to the target with significantly reduced dose to the ipsilateral lung and, in the case of the left-breast patient, reduced dose to the heart, than the tangential field plans. In both the right-sided and left-sided breast plans, the dose to other normal structures was similar to that from conventional plans and was much smaller than that from the 9-field IMRT plans. The optimized electron beam provided between 70 to 80% of the prescribed dose at the depth of maximum dose of the electron beam. The combined electron and IMRT technique showed improvement over the conventional treatment technique using tangential fields with reduced dose to the ipsilateral lung and the heart. The customized beam directions of the four IMRT fields also kept the dose to other critical structures to a minimum. (author)

  7. Computerized treatment planning systems for external photon beam radiotherapy

    International Nuclear Information System (INIS)

    Evans, M.D.C.

    2005-01-01

    Computerized treatment planning systems (TPSs) are used in external beam radiotherapy to generate beam shapes and dose distributions with the intent to maximize tumour control and minimize normal tissue complications. Patient anatomy and tumour targets can be represented as 3-D models. The entire process of treatment planning involves many steps and the medical physicist is responsible for the overall integrity of the computerized TPS to accurately and reliably produce dose distributions and associated calculations for external beam radiotherapy. The planning itself is most commonly carried out by a dosimetrist, and the plan must be approved by a radiation oncologist before implementation in actual patient treatments. Treatment planning prior to the 1970s was generally carried out through the manual manipulation of standard isodose charts on to patient body contours that were generated by direct tracing or lead wire representation, and relied heavily on the judicious choice of beam weight and wedging by an experienced dosimetrist. The simultaneous development of computed tomography (CT), along with the advent of readily accessible computing power from the 1970s on, led to the development of CT based computerized treatment planning, providing the ability to view dose distributions directly superimposed upon a patient's axial anatomy. The entire treatment planning process involves many steps, beginning from beam data acquisition and entry into the computerized TPS, through patient data acquisition, to treatment plan generation and the final transfer of data to the treatment machine. Successive improvements in treatment planning hardware and software have been most notable in the graphics, calculation and optimization aspects of current systems. Systems encompassing the 'Virtual Patient' are able to display beam's eye views (BEVs) of radiation beams and digitally reconstructed radiographs (DRRs) for arbitrary dose distributions. Dose calculations have evolved from

  8. Electron-beam curing of epoxy resins

    Indian Academy of Sciences (India)

    Electron-beam (e-beam) induced polymerization of epoxy resins proceeds via cationic mechanism in presence of suitable photoinitiator. Despite good thermal properties and significant processing advantages, epoxy-based composites manufactured using e-beam curing suffer from low compressive strength, poor ...

  9. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  10. EIC Electron Beam Polarimetry Workshop Summary

    International Nuclear Information System (INIS)

    Lorenzon, W.

    2008-01-01

    A summary of the Precision Electron Beam Polarimetry Workshop for a future Electron Ion Collider (EIC) is presented. The workshop was hosted by the University of Michigan Physics Department in Ann Arbor on August 23-24, 2007 with the goal to explore and study the electron beam polarimetry issues associated with the EIC to achieve sub-1% precision in polarization determination. Ideas are being presented that were exchanged among experts in electron polarimetry and source and accelerator design to examine existing and novel electron beam polarization measurement schemes

  11. A directly heated electron beam line source

    International Nuclear Information System (INIS)

    Iqbal, M.; Masood, K.; Rafiq, M.; Chaudhry, M.A.

    2002-05-01

    A 140-mm cathode length, Electron Beam Line Source with a high degree of focusing of the beam is constructed. The design principles and basic characteristic considerations for electron beam line source consists of parallel plate electrode geometric array as well as a beam power of 35kW are worked out. The dimensions of the beam at the work site are 1.25xl00mm. The gun is designed basically for the study of evaporation and deposition characteristic of refractory metals for laboratory use. However, it may be equally used for melting and casting of these metals. (author)

  12. Electron beam generation form a superemissive cathode

    International Nuclear Information System (INIS)

    Hsu, T.-Y.; Liou, R.-L.; Kirkman-Amemiya, G.; Gundersen, M.A.

    1991-01-01

    An experimental study of electron beams produced by a superemissive cathode in the Back-Lighted Thyratron (BLT) and the pseudospark is presented. This work is motivated by experiments demonstrating very high current densities (≥10 kA/cm 2 over an area of 1 cm 2 ) from the pseudospark and BLT cathode. This high-density current is produced by field-enhanced thermionic emission from the ion beam-heated surface of a molybdenum cathode. This work reports the use of this cathode as a beam source, and is to be distinguished from previous work reporting hollow cathode-produced electron beams. An electron beam of more than 260 A Peak current has been produced with 15 kV applied voltage. An efficiency of ∼10% is estimated. These experimental results encourage further investigation of the super-emissive cathode as an intense electron beam source for applications including accelerator technology

  13. An electron beam imaging system for quality assurance in IORT

    Science.gov (United States)

    Casali, F.; Rossi, M.; Morigi, M. P.; Brancaccio, R.; Paltrinieri, E.; Bettuzzi, M.; Romani, D.; Ciocca, M.; Tosi, G.; Ronsivalle, C.; Vignati, M.

    2004-01-01

    Intraoperative radiation therapy is a special radiotherapy technique, which enables a high dose of radiation to be given in a single fraction during oncological surgery. The major stumbling block to the large-scale application of the technique is the transfer of the patient, with an open wound, from the operating room to the radiation therapy bunker, with the consequent organisational problems and the increased risk of infection. To overcome these limitations, in the last few years a new kind of linear accelerator, the Novac 7, conceived for direct use in the surgical room, has become available. Novac 7 can deliver electron beams of different energies (3, 5, 7 and 9 MeV), with a high dose rate (up to 20 Gy/min). The aim of this work, funded by ENEA in the framework of a research contract, is the development of an innovative system for on-line measurements of 2D dose distributions and electron beam characterisation, before radiotherapy treatment with Novac 7. The system is made up of the following components: (a) an electron-light converter; (b) a 14 bit cooled CCD camera; (c) a personal computer with an ad hoc written software for image acquisition and processing. The performances of the prototype have been characterised experimentally with different electron-light converters. Several tests have concerned the assessment of the detector response as a function of impulse number and electron beam energy. Finally, the experimental results concerning beam profiles have been compared with data acquired with other dosimetric techniques. The achieved results make it possible to say that the developed system is suitable for fast quality assurance measurements and verification of 2D dose distributions.

  14. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  15. Intraoperative Electron Radiotherapy for the Management of Aggressive Fibromatosis

    International Nuclear Information System (INIS)

    Roeder, Falk; Timke, Carmen; Oertel, Susanne; Hensley, Frank W.; Bischof, Marc; Muenter, Marc W.; Weitz, Juergen; Buchler, Markus W.; Lehner, Burkhard; Debus, Juergen; Krempien, Robert

    2010-01-01

    Purpose: We analyzed our experience with intraoperative electron radiotherapy (IOERT) followed by moderate doses of external beam radiotherapy (EBRT) after organ-sparing surgery in patients with primary or recurrent aggressive fibromatosis. Methods and Materials: Indication for IOERT and postoperative EBRT as an individual treatment approach to avoid mutilating surgical procedures was seen when complete surgical removal seemed to be unlikely or impossible. A total of 31 lesions in 30 patients were treated by surgery and IOERT with a median dose of 12 Gy. Median age was 31 years (range, 13-59 years). Resection status was close margin in six lesions, microscopically positive in 13, and macroscopically positive in 12. Median tumor size was 9 cm. In all, 25 patients received additional EBRT, with a median dose of 45 Gy (range, 36-54 Gy). Results: After a median follow-up of 32 months (range, 3-139 months), no disease-related deaths occurred. A total of five local recurrences were seen, resulting in actuarial 3-year local control rates of 82% overall and 91% inside the IOERT areas. Trends to improved local control were seen for older age (>31 years) and negative margins, but none of these factors reached significance. Perioperative complications were found in six patients, in particular as wound healing disturbances in five patients and venous thrombosis in one patient. Late toxicity was seen in five patients. Conclusion: Introduction of IOERT into a multimodal treatment approach in patients with aggressive fibromatosis is feasible with low toxicity and yielded good local control rates even in patients with microscopical or gross residual disease.

  16. Three-dimensional electron-beam dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Shiu, A.S.

    1988-01-01

    The MDAH pencil-beam algorithm developed by Hogstrom et al (1981) has been widely used in clinics for electron-beam dose calculations for radiotherapy treatment planning. The primary objective of this research was to address several deficiencies of that algorithm and to develop an enhanced version. Two enhancements were incorporated into the pencil-beam algorithm; one models fluence rather than planar fluence, and the other models the bremsstrahlung dose using measured beam data. Comparisons of the resulting calculated dose distributions with measured dose distributions for several test phantoms have been made. From these results it is concluded (1) that the fluence-based algorithm is more accurate to use for the dose calculation in an inhomogeneous slab phantom, and (2) the fluence-based calculation provides only a limited improvement to the accuracy the calculated dose in the region just downstream of the lateral edge of an inhomogeneity. A pencil-beam redefinition model was developed for the calculation of electron-beam dose distributions in three dimensions.

  17. Three-dimensional electron-beam dose calculations

    International Nuclear Information System (INIS)

    Shiu, A.S.

    1988-01-01

    The MDAH pencil-beam algorithm developed by Hogstrom et al (1981) has been widely used in clinics for electron-beam dose calculations for radiotherapy treatment planning. The primary objective of this research was to address several deficiencies of that algorithm and to develop an enhanced version. Two enhancements were incorporated into the pencil-beam algorithm; one models fluence rather than planar fluence, and the other models the bremsstrahlung dose using measured beam data. Comparisons of the resulting calculated dose distributions with measured dose distributions for several test phantoms have been made. From these results it is concluded (1) that the fluence-based algorithm is more accurate to use for the dose calculation in an inhomogeneous slab phantom, and (2) the fluence-based calculation provides only a limited improvement to the accuracy the calculated dose in the region just downstream of the lateral edge of an inhomogeneity. A pencil-beam redefinition model was developed for the calculation of electron-beam dose distributions in three dimensions

  18. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soevik, Aaste; Skogmo, Hege K. (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)), E-mail: aste.sovik@nvh.no; Roedal, Jan (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)); Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik (Dept. of Medical Physics, The Norwegian Radium Hospital, Oslo Univ. Hospital, Oslo (Norway))

    2010-10-15

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  19. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    International Nuclear Information System (INIS)

    Soevik, Aaste; Skogmo, Hege K.; Roedal, Jan; Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik

    2010-01-01

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  20. High power electron beam dumps at CEBAF

    International Nuclear Information System (INIS)

    Wiseman, M.; Sinclair, C.K.; Whitney, R.; Zarecky, M.

    1997-01-01

    The CEBAF accelerator produces a very small emittance CW electron beam of up to 200 μA average current. The resulting beam power, up to 1 MW at 5 GeV, and the very high beam power density, pose challenging problems for beam dump design. Two styles of high power dumps have been developed. The first, rated for 100+ kW, is used for beam tune-up and accelerator commissioning. The beam power is entirely contained in metal in this dump, minimizing the problems associated with radioactive water handling. Full power 1 MW dumps are used with the experimental halls. In these dumps, one-third of the beam power is directly absorbed in water. Both dump designs require the beam to be rastered when the smallest beam sizes are used. Design details for each of these dumps will be presented

  1. Electron beam processing of wastewater in Malaysia

    International Nuclear Information System (INIS)

    Zulkafli Ghazali; Khairul Zaman Dahlan; Ting Teo Ming; Khomsaton A. Bakar

    2006-01-01

    Electron beam processing technology started in Malaysia in 1991 when two accelerators were installed through JICA cooperation to perform medical product sterilization project. Since then several private companies have installed electron accelerators to develop in removing volatile organic materials and to demonstrate flue gas treatment. In this country report, effort on electron beam processing of wastewater or contaminated groundwater is presented: After de-coloration tests using gamma rays as function of radiation doses, electron beam treatment of textile industry wastewater as function of beam energy and current intensity as well as with combined treatment such as aeration or biological treatment to examine the effectiveness in color and BOD or COD change has been carried out and the main results are reported. Furthermore, the present technique was examined to apply in river water treatment for use as drinking water. Techno-economic feasibility study for recycling of industrial waste water using electron beam technology is now underway. (S. Ohno)

  2. Electron beam curing of polymer matrix composites

    International Nuclear Information System (INIS)

    Janke, C.J.; Wheeler, D.; Saunders, C.

    1998-01-01

    The purpose of the CRADA was to conduct research and development activities to better understand and utilize the electron beam PMC curing technology. This technology will be used to replace or supplement existing PMC thermal curing processes in Department of Energy (DOE) Defense Programs (DP) projects and American aircraft and aerospace industries. This effort involved Lockheed Martin Energy Systems, Inc./Lockheed Martin Energy Research Corp. (Contractor), Sandia National Laboratories, and ten industrial Participants including four major aircraft and aerospace companies, three advanced materials companies, and three electron beam processing organizations. The technical objective of the CRADA was to synthesize and/or modify high performance, electron beam curable materials that meet specific end-use application requirements. There were six tasks in this CRADA including: Electron beam materials development; Electron beam database development; Economic analysis; Low-cost Electron Beam tooling development; Electron beam curing systems integration; and Demonstration articles/prototype structures development. The contractor managed, participated and integrated all the tasks, and optimized the project efforts through the coordination, exchange, and dissemination of information to the project participants. Members of the Contractor team were also the principal inventors on several electron beam related patents and a 1997 R and D 100 Award winner on Electron-Beam-Curable Cationic Epoxy Resins. The CRADA achieved a major breakthrough for the composites industry by having successfully developed high-performance electron beam curable cationic epoxy resins for use in composites, adhesives, tooling compounds, potting compounds, syntactic foams, etc. UCB Chemicals, the world's largest supplier of radiation-curable polymers, has acquired a license to produce and sell these resins worldwide

  3. Electron beam treatment of wastewater

    International Nuclear Information System (INIS)

    Arai, H.; Hosono, M.; Shimizu, K.; Sugiyama, M.

    1991-01-01

    Supernatant comes from dewaterization of sewage sludge, and contains biologically nondegradable organics so that it is hard to be treated by conventional activated sludge. By electron beam (EB) irradiation, any kinds of organics in water can be oxidized to biodegradable organic acids. We studied the treatment of supernatant by application of this effect. The direct irradiation of the original supernatant was found not to be so effective to decrease COD. In order to increase the irradiation effect, supernatant was pretreated biologically to decrease the biodegradable organics in it. The chemical oxygen demand (COD) and biochemical oxygen demand (BOD) were decreased from 800 and 910 mg/L to 78 and 5 mg/L by this pretreatment, respectively. This pretreated supernatant was irradiated by EB of 2 MeV using a batch type reactor. The COD was gradually decreased with dose. In contrast, BOD was increased markedly, indicating increase in biodegradability. The irradiated sample water was treated biologically again. After the final biological treatment, COD was decreased below 30 mg/L in the case of 10 - 12 kGy irradiation. Finally, the initial COD of 800 mg/L was decreased below 30 mg/L by the combination of EB irradiation and biological treatment. The cost of irradiation for this process was evaluated preliminarily. (author)

  4. Development of a diamond dosimeter for measuring the absorbed dose in small beams used in stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Marsolat, F.

    2014-01-01

    Stereotactic radiotherapy is a relatively recent technique used for the treatment of small benign and malignant tumors with small radiation beams. The clinical efficiency of this technique has been proved. However, the measurement of absolute and relative dose in small beams is not possible currently due to the lack of suited detectors for these measurements. In small beam dosimetry, the detector has to be as close as possible to tissue equivalence and exhibit a small detection volume due to the lack of lateral electronic equilibrium. Characteristics of diamond (water equivalent material Z=6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. In this thesis, we developed a dosimeter prototype for small beams, based on CVD synthetic single crystal diamond. The diamond samples were characterized optically and their detection properties were investigated under X-rays and alpha-particles. First diamond dosimeter prototypes were tested with small beams produced by several stereotactic machines. Studies using Monte Carlo simulations were performed in order to optimize the parameters involved in the detector response in small beams. This leaded to a final diamond dosimeter prototype that respects all radiotherapy centers requirements, in both standard and small beams. (author) [fr

  5. Electron beam energy monitoring using thermoluminescent dosimeters and electron back scattering

    International Nuclear Information System (INIS)

    Nelson, Vinod; Gray, Alison

    2013-01-01

    Periodic checks of megavoltage electron beam quality are a fundamental requirement in ensuring accurate radiotherapy treatment delivery. In the present work, thermoluminescent dosimeters (TLDs) positioned on either side of a lead sheet at the surface of a water equivalent phantom were used to monitor electron beam quality using the electron backscattering method. TLD100 and TLD100H were evaluated as upstream detectors and TLD200, TLD400 and TLD500 were evaluated as downstream detectors. The evaluation assessed the test sensitivity and correlation, long and short term reproducibility, dose dependence and glow curve features. A prototype of an in-air jig suitable for use in postal TLD dose audits was also developed and an initial evaluation performed. The results indicate that the TLD100-TLD200 combination provides a sensitive and reproducible method to monitor electron beam quality. The light weight and easily fabricated in-air jig was found to produce acceptable results and has the potential to be used by radiation monitoring agencies to carry out TLD postal quality assurance audits, similar to audits presently being conducted for photon beams. -- Highlights: ► Monitoring electron beam quality via electron backscattering was investigated. ► Different thermoluminescent materials were evaluated as detectors. ► A TLD100-TLD200 combination produced the most sensitive and reproducible results. ► An in-air jig was evaluated to allow measurements via postal dose audits

  6. Electron backscattering for process control in electron beam welding

    International Nuclear Information System (INIS)

    Ardenne, T. von; Panzer, S.

    1983-01-01

    A number of solutions to the automation of electron beam welding is presented. On the basis of electron backscattering a complex system of process control has been developed. It allows an enlarged imaging of the material's surface, improved adjustment of the beam focusing and definite focus positioning. Furthermore, both manual and automated positioning of the electron beam before and during the welding process has become possible. Monitoring of the welding process for meeting standard welding requirements can be achieved with the aid of a control quantity derived from the results of electronic evaluation of the high-frequency electron backscattering

  7. Generation of Nondiffracting Electron Bessel Beams

    Directory of Open Access Journals (Sweden)

    Vincenzo Grillo

    2014-01-01

    Full Text Available Almost 30 years ago, Durnin discovered that an optical beam with a transverse intensity profile in the form of a Bessel function of the first order is immune to the effects of diffraction. Unlike most laser beams, which spread upon propagation, the transverse distribution of these Bessel beams remains constant. Electrons also obey a wave equation (the Schrödinger equation, and therefore Bessel beams also exist for electron waves. We generate an electron Bessel beam by diffracting electrons from a nanoscale phase hologram. The hologram imposes a conical phase structure on the electron wave-packet spectrum, thus transforming it into a conical superposition of infinite plane waves, that is, a Bessel beam. We verify experimentally that these beams can propagate for 0.6 m without measurable spreading and can also reconstruct their intensity distributions after being partially obstructed by an obstacle. Finally, we show by numerical calculations that the performance of an electron microscope can be increased dramatically through use of these beams.

  8. Electron beam collimation with a photon MLC for standard electron treatments

    Science.gov (United States)

    Mueller, S.; Fix, M. K.; Henzen, D.; Frei, D.; Frauchiger, D.; Loessl, K.; Stampanoni, M. F. M.; Manser, P.

    2018-01-01

    Standard electron treatments are currently still performed using standard or molded patient-specific cut-outs placed in the electron applicator. Replacing cut-outs and electron applicators with a photon multileaf collimator (pMLC) for electron beam collimation would make standard electron treatments more efficient and would facilitate advanced treatment techniques like modulated electron radiotherapy (MERT) and mixed beam radiotherapy (MBRT). In this work, a multiple source Monte Carlo beam model for pMLC shaped electron beams commissioned at a source-to-surface distance (SSD) of 70 cm is extended for SSDs of up to 100 cm and validated for several Varian treatment units with field sizes typically used for standard electron treatments. Measurements and dose calculations agree generally within 3% of the maximal dose or 2 mm distance to agreement. To evaluate the dosimetric consequences of using pMLC collimated electron beams for standard electron treatments, pMLC-based and cut-out-based treatment plans are created for a left and a right breast boost, a sternum, a testis and a parotid gland case. The treatment plans consist of a single electron field, either alone (1E) or in combination with two 3D conformal tangential photon fields (1E2X). For each case, a pMLC plan with similar treatment plan quality in terms of dose homogeneity to the target and absolute mean dose values to the organs at risk (OARs) compared to a cut-out plan is found. The absolute mean dose to an OAR is slightly increased for pMLC-based compared to cut-out-based 1E plans if the OAR is located laterally close to the target with respect to beam direction, or if a 6 MeV electron beam is used at an extended SSD. In conclusion, treatment plans using cut-out collimation can be replaced by plans of similar treatment plan quality using pMLC collimation with accurately calculated dose distributions.

  9. Attainment of Electron Beam Suitable for Medium Energy Electron Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Seletskiy, Sergei M. [Univ. of Rochester, NY (United States)

    2005-01-01

    Electron cooling of charged particle beams is a well-established technique at electron energies of up to 300 keV. However, up to the present time the advance of electron cooling to the MeV-range energies has remained a purely theoretical possibility. The electron cooling project at Fermilab has recently demonstrated the ¯rst cooling of 8.9 GeV/c antiprotons in the Recycler ring, and therefore, has proved the validity of the idea of relativistic electron cool- ing. The Recycler Electron Cooler (REC) is the key component of the Teva- tron Run II luminosity upgrade project. Its performance depends critically on the quality of electron beam. A stable electron beam of 4.3 MeV car- rying 0.5 A of DC current is required. The beam suitable for the Recycler Electron Cooler must have an angular spread not exceeding 200 ¹rad. The full-scale prototype of the REC was designed, built and tested at Fermilab in the Wideband laboratory to study the feasibility of attaining the high-quality electron beam. In this thesis I describe various aspects of development of the Fermilab electron cooling system, and the techniques used to obtain the electron beam suitable for the cooling process. In particular I emphasize those aspects of the work for which I was principally responsible.

  10. Electron Beam Lithography for nano-patterning

    DEFF Research Database (Denmark)

    Greibe, Tine; Anhøj, Thomas Aarøe; Khomtchenko, Elena

    2014-01-01

    Electron beam lithography is a versatile tool for fabrication of nano-sized patterns. The patterns are generated by scanning a focused beam of high-energy electrons onto a substrate coated with a thin layer of electron-sensitive polymer (resist), i.e. by directly writing custom-made patterns...... in a polymer. Electron beam lithography is a suitable method for nano-sized production, research, or development of semiconductor components on a low-volume level. Here, we present electron beam lithography available at DTU Danchip. We expertize a JEOL 9500FZ with electrons accelerated to an energy of 100ke......V and focused to a beam spot size down to ~5nm. The electron beam can scan across the substrate with a speed of 100MHz and can write areas of 1mm x 1mm without stitching. In order to ensure high-precision patterning, the beam position on the substrate is controlled by a two-stage deflector system and substrates...

  11. Facilities for radiotherapy with ion beams status and worldwide developments

    CERN Document Server

    Wolf, B H

    1999-01-01

    Forty-five years after the first ion beam therapy in Berkeley around 25,000 cancer patients worldwide have been treated successfully. Ion accelerators, designed for nuclear research, delivered most of this treatment. The first hospital-based facility started operation in 1998 at Loma Linda California, the first for heavier ions at Chiba, Japan in 1994 and the first commercially delivered facilities started operation in 1998 at Kashiwa, Japan. In 2000, the Harvard Medical Centre, Boston, US, will commence operation and several new facilities are planned or under construction worldwide, although none in Australia. This paper will discuss the physical and biological advantages of ion beams over x-rays and electrons. In the treatment of cancer patients ion beam therapy is especially suited for localised tumours in radiation sensitive areas like skull or spine. Heavier ions are also effective in anoxic tumour cells (found around the normally oxygenated cell population). An additional advantage of the heavier carbo...

  12. Intense relativistic electron beam: generation and propagation

    International Nuclear Information System (INIS)

    Mittal, K.C.; Mondal, J.

    2010-01-01

    A general review of relativistic electron beam extracted from explosive field emission diode has been presented here. The beam current in the diode gap taking into account cathode and anode plasma expansion velocity and excluding the self magnetic field effect is directly proportional to gap voltage V 3/2 and inversely proportional to the square of the effective diode gap (d-vt). In the limit of high current, self magnetic field focusing effect comes into play and results in a critical current at which pinching will take place. When the diode current exceeds the critical current, the electron flow is in the para-potential regime. Different diode geometries such as planner, coaxial, rod-pinched, reflex triode are discussed qualitatively. When the beam is injected into a vacuum drift tube the propagation of the beam is only possible in presence of a strong axial magnetic field which prevents the beam expansion in the radial direction. If the beam is injected in the drift tube filled with dense plasma, then the redistribution of the plasma electrons effectively neutralizes the beam space charge, resulting subsequent propagation of the beam along the drift tube. The beam propagation through neutral gas is similar to the plasma filled drift tube. In this case both the neutral gas pressure and the beam current regulate the transmission of the REB. (author)

  13. Beam-ripple monitor with secondary electrons

    International Nuclear Information System (INIS)

    Sato, Shinji; Kanazawa, Mitsutaka; Noda, Koji; Takada, Eiichi; Komiyama, Akihito; Ichinohe, Ken-ichi; Sano, Yoshinobu

    1997-01-01

    To replace the scintillation-ripple monitor, we have developed a new monitor with a smaller destructive effect on the beam. In this monitor, we use secondary electrons emitted from an aluminum foil with a thickness of 2 μm. The signals of secondary electrons are amplified by an electron multiplier having a maximum gain of 10 6 . By using the new monitor, we could clearly observe the beam ripple with a beam intensity of 3.6x10 8 pps (particle per second). This monitor can also be used as an intensity monitor in the range of 10 4 - 10 9 pps. (author)

  14. Electron beam processing of polymers and composites

    International Nuclear Information System (INIS)

    Singh, R. P.

    1994-01-01

    Electron beam processing has emerged as one of the foremost techniques for surface treatment of materials. Recently polymers and advanced composites are being treated with the electron beams of 1-10 MeV. In polymers the surface improvement is caused by radiation curing, cross linking and grafting. It has made inroads in vital sector of plastic industries in industrially advanced countries. Advanced composites can also be cured at ambient temperatures thus avoiding emission of volatiles during curing. Details of all these aspects of electron beam processing of polymers and composites are given. (author). 9 refs., 1 fig

  15. Operational experience with SLAC's beam containment electronics

    International Nuclear Information System (INIS)

    Constant, T.N.; Crook, K.; Heggie, D.

    1977-03-01

    Considerable operating experience was accumulated at SLAC with an extensive electronic system for the containment of high power accelerated beams. Average beam power at SLAC can approach 900 kilowatts with the potential for burning through beam stoppers, protection collimators, and other power absorbers within a few seconds. Fast, reliable, and redundant electronic monitoring circuits have been employed to provide some of the safeguards necessary for minimizing the risk to personnel. The electronic systems are described, and the design philosophy and operating experience are discussed

  16. Recent developments in electron beam machine technology

    International Nuclear Information System (INIS)

    Sadat, T.; Ross, A.; Leveziel, H.

    1994-01-01

    Electron beam accelerator provides ionisation energy for industrial processing. Electron beam accelerators are increasingly used for decontamination, conservation and disinfestation of food, for sterilization of medical products, and for polymerisation of materials. These machines are easy to install into a production factory as the radiation stops as soon as the machine is switched off. This safety advantage, together with the flexibility of use of these highly automated machines, has allowed the electron beam accelerator to become an important production tool. (author). 23 refs., 6 figs., 2 tabs

  17. Review of electron beam therapy physics

    International Nuclear Information System (INIS)

    Hogstrom, Kenneth R; Almond, Peter R

    2006-01-01

    For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

  18. Review of electron beam therapy physics.

    Science.gov (United States)

    Hogstrom, Kenneth R; Almond, Peter R

    2006-07-07

    For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed.

  19. Electron Beam Scanning in Industrial Applications

    Science.gov (United States)

    Jongen, Yves; Herer, Arnold

    1996-05-01

    Scanned electron beams are used within many industries for applications such as sterilization of medical disposables, crosslinking of wire and cables insulating jackets, polymerization and degradation of resins and biomaterials, modification of semiconductors, coloration of gemstones and glasses, removal of oxides from coal plant flue gasses, and the curing of advanced composites and other molded forms. X-rays generated from scanned electron beams make yet other applications, such as food irradiation, viable. Typical accelerators for these applications range in beam energy from 0.5MeV to 10 MeV, with beam powers between 5 to 500kW and scanning widths between 20 and 300 cm. Since precise control of dose delivery is required in many of these applications, the integration of beam characteristics, product conveyance, and beam scanning mechanisms must be well understood and optimized. Fundamental issues and some case examples are presented.

  20. Numerical simulation of electron beam welding with beam oscillations

    Science.gov (United States)

    Trushnikov, D. N.; Permyakov, G. L.

    2017-02-01

    This research examines the process of electron-beam welding in a keyhole mode with the use of beam oscillations. We study the impact of various beam oscillations and their parameters on the shape of the keyhole, the flow of heat and mass transfer processes and weld parameters to develop methodological recommendations. A numerical three-dimensional mathematical model of electron beam welding is presented. The model was developed on the basis of a heat conduction equation and a Navier-Stokes equation taking into account phase transitions at the interface of a solid and liquid phase and thermocapillary convection (Marangoni effect). The shape of the keyhole is determined based on experimental data on the parameters of the secondary signal by using the method of a synchronous accumulation. Calculations of thermal and hydrodynamic processes were carried out based on a computer cluster, using a simulation package COMSOL Multiphysics.

  1. Development of neutral beam source using electron beam excited plasma

    International Nuclear Information System (INIS)

    Hara, Yasuhiro; Hamagaki, Manabu; Mise, Takaya; Hara, Tamio

    2011-01-01

    A low-energy neutral beam (NB) source, which consists of an electron-beam-excited plasma (EBEP) source and two carbon electrodes, has been developed for damageless etching of ultra-large-scale integrated (ULSI) devices. It has been confirmed that the Ar ion beam energy was controlled by the acceleration voltage and the beam profile had good uniformity over the diameter of 80 mm. Dry etching of a Si wafer at the floating potential has been carried out by Ar NB. Si sputtering yield by an Ar NB clearly depends on the acceleration voltage. This result shows that the NB has been generated through the charge exchange reaction from the ion beam in the process chamber. (author)

  2. Electron-beam initiated HF lasers

    International Nuclear Information System (INIS)

    Gerber, R.A.; Patterson, E.L.

    1975-01-01

    Electron beams were used to ignite hydrogen/fluorine mixtures, producing laser energies up to 4.2 kJ, and giving hope that this approach may soon produce energy levels suitable for laser-fusion studies. (auth)

  3. Horizontal electron beam welding for stainless steels

    International Nuclear Information System (INIS)

    Martin, P.; Olivera, J.J.

    1977-01-01

    Stainless steel samples have been realized by local vacuum apparatus for electron beam welding applications to reactor core shell realizations. The best welding parameters have been determined by a systematic study. The welds have been characterized by mechanical tests [fr

  4. Scrap uranium recycling via electron beam melting

    International Nuclear Information System (INIS)

    McKoon, R.

    1993-11-01

    A program is underway at the Lawrence Livermore National Laboratory (LLNL) to recycle scrap uranium metal. Currently, much of the material from forging and machining processes is considered radioactive waste and is disposed of by oxidation and encapsulation at significant cost. In the recycling process, uranium and uranium alloys in various forms will be processed by electron beam melting and continuously cast into ingots meeting applicable specifications for virgin material. Existing vacuum processing facilities at LLNL are in compliance with all current federal and state environmental, safety and health regulations for the electron beam melting and vaporization of uranium metal. One of these facilities has been retrofitted with an auxiliary electron beam gun system, water-cooled hearth, crucible and ingot puller to create an electron beam melt furnace. In this furnace, basic process R ampersand D on uranium recycling will be performed with the goal of eventual transfer of this technology to a production facility

  5. Ion beam processing of advanced electronic materials

    International Nuclear Information System (INIS)

    Cheung, N.W.; Marwick, A.D.; Roberto, J.B.

    1989-01-01

    This report contains research programs discussed at the materials research society symposia on ion beam processing of advanced electronic materials. Major topics include: shallow implantation and solid-phase epitaxy; damage effects; focused ion beams; MeV implantation; high-dose implantation; implantation in III-V materials and multilayers; and implantation in electronic materials. Individual projects are processed separately for the data bases

  6. Ion beam processing of advanced electronic materials

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, N.W.; Marwick, A.D.; Roberto, J.B. (eds.) (California Univ., Berkeley, CA (USA); International Business Machines Corp., Yorktown Heights, NY (USA). Thomas J. Watson Research Center; Oak Ridge National Lab., TN (USA))

    1989-01-01

    This report contains research programs discussed at the materials research society symposia on ion beam processing of advanced electronic materials. Major topics include: shallow implantation and solid-phase epitaxy; damage effects; focused ion beams; MeV implantation; high-dose implantation; implantation in III-V materials and multilayers; and implantation in electronic materials. Individual projects are processed separately for the data bases. (CBS)

  7. DOSE-ESCALATED EXTERNAL BEAM RADIOTHERAPY DURING HORMONO-RADIOTHERAPY FOR PROSTATE CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2016-01-01

    Full Text Available Introduction. The introduction of modern technologies of conformal external beam radiotherapy (EBRT into clinical practice for the treatment of prostate cancer requires proper quality assurance measures as well as a careful analysis of both the efficacy and toxicity data of treatments. The purpose of this study was to inves- tigate tolerance and the immediate efficacy of conformal dose-escalated EBRT during hormono-radiotherapy for prostate cancer. material and methods. The study involved 156 prostate cancer patients treated with EBRT. Among them, 30 patients received a total dose of 70 Gy, and in 126 patients the total dose was esca- lated to 72-76 Gy (median total dose - 74.0 Gy. Fifty-nine patients received intensity modulated radiation therapy. Results. The prescribed course of treatment was completed in all the patients with prostate cancer. Acute radiation-induced bladder reactions (RTOG were observed in 50 (32.1 % patients, of whom 48 (30.8 % experienced grade I reactions, and 2 (1.3 % experienced grade II reactions. Eighteen (11.5 % patients had radiation-induced rectum reactions, not above grade I. The development of grade II dysuric phenomena necessitated treatment interruption only in two patients. Of 9 (5.8 % patients who had late bladder complica- tions (RTOG/EORTC, 8 (5.1 % patients developed grade I complications, and one (0.6 % patient developed grade II complications. Of 11 (7.1 % patients who had rectum complications, 8 (5.1 % patients developed grade I complications, and 3 (1.9 % patients developed grade II complications. No patients experienced the increase in toxicity of treatment during dose escalation up to a total dose exceeding 70 Gy. During the follow-up period, only one patient developed recurrent disease. Conclusion. The results of our study suggest acceptable levels of toxicity following a continuous course of dose-escalated EBRT given in conjunction with hormono-radiotherapy to prostate cancer patients. Further

  8. Primary beams of an electron beam ion source (EBIS)

    International Nuclear Information System (INIS)

    Lenoir-Zink, E.

    1986-06-01

    Electron guns for the ion sources of the SATURN II facility were tested and compared with models. The guns tested were a gun with 36 mm diameter cathode, 7 mm, 4 mm, 4 mm with insulated Whenelt, and 8 mm. A lanthanium hexaboride cathode is presented. For the primary ion beams, zeolite and plasma sources were realized. In DIONE, which will replace CRYEBIS as ion source in SATURNE, the density of the electron beam compressed within the maximum magnetic field can be evaluated. Results indicate a factor of 3 improvement compared with CRYEBIS. Lithium sources can be used, but gas sources do not produce significant improvements [fr

  9. The electron beam damage of synthetic polymers

    International Nuclear Information System (INIS)

    Vesely, D.

    1977-01-01

    Beam damage is a severe limitation when the electron microscope is applied to the study of microstructures of synthetic polymers. There is no practical method for increasing significantly the critical dose required to damage a specimen. It is therefore necessary to utilize fully the information present in the electron beam by efficient recording and by eliminating unnecessary accumulation of irradiation damage. The STEM technique provides a unique facility for this type of work mainly because of localized and well controlled beam damage in both the image and microdiffraction modes. Examples are given. (author)

  10. Plasma heating by a relativistic electron beam

    International Nuclear Information System (INIS)

    Janssen, G.C.A.M.

    1983-01-01

    This thesis is devoted to the interaction of a Relativistic Electron Beam (REB) with a plasma. The goal of the experiment described herein is to study in detail the mechanism of energy transfer from the beam to the plasma. The beam particles have an energy of 800 keV, a current of 6 kA, a diameter of 3 cm and an adjustable pulse length of 50-150 ns. This beam is injected into cold hydrogen and helium plasmas with densities ranging from 10 18 to 10 20 m -3 . First, the technical aspects of the experiment are described. Then measurements on the hf fields excited by the REB-plasma are presented (optical line profiles and spectra of beam electrons). The final section is devoted to plasma heating. (Auth.)

  11. Guassian beams and electron acceleration

    International Nuclear Information System (INIS)

    Collins, M.; Castillo, R.; Osman, F.; Evans, P.; Stiat-Gardener, T.; Hora, H.

    2000-01-01

    Full text: A guassian solution to the free space wave equation to fourth order is derived using the Fourier transform method. Higher order solutions can be generated, as needed, using the convolution method. These results are used to investigate the acceleration of an electron in a laser field. The acceleration is determined if energy is transferred to a relativistic electron, this energy transfer can be determined by calculating the change in the potential of the electron

  12. A simple electron-beam lithography system

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Madsen, Dorte Nørgaard; Bøggild, Peter

    2005-01-01

    A large number of applications of electron-beam lithography (EBL) systems in nanotechnology have been demonstrated in recent years. In this paper we present a simple and general-purpose EBL system constructed by insertion of an electrostatic deflector plate system at the electron-beam exit...... of the column of a scanning electron microscope (SEM). The system can easily be mounted on most standard SEM systems. The tested setup allows an area of up to about 50 x 50 pm to be scanned, if the upper limit for acceptable reduction of the SEM resolution is set to 10 run. We demonstrate how the EBL system can...

  13. Green coffee decontamination by electron beam irradiation

    International Nuclear Information System (INIS)

    Nemtanu, Monica R.; Brasoveanu, Mirela; Grecu, Maria Nicoleta; Minea, R.

    2005-01-01

    Microbiological load of green coffee is a real problem considering that it is extremely sensitive to contamination. Irradiation is a decontamination method for a lot of foodstuffs, being a feasible, very effective and environment friendly one. Beans and ground green coffee were irradiated with electron beams up to 40 kGy. Microbial load, rheological behavior, electron paramagnetic resonance (EPR) and visible spectroscopy were carried out. The results show that electron beam irradiation of green coffee could decontaminate it without severe changes in its properties

  14. AECL IMPELA electron beam industrial irradiators

    International Nuclear Information System (INIS)

    Labrie, J.P.; Drewell, N.H.; Ebrahim, N.A.; Lawrence, C.B.; Mason, V.A.; Ungrin, J.; White, B.F.

    1989-01-01

    A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the IMPELA 10/50 (10 MeV, 50 kW), is in the final stages of assembly at Chalk River Nuclear Laboratories. The IMPELA 10/50 is constructed around a 3.25 m long, high-power-capacity accelerator structure operated at a duty factor of 5%. Beam loading exceeds 60%. The rf power is provided by a 2 MW/150 kW modulated-anode klystron protected from load mismatches by a circulator. This prototype will be used to demonstrate the reliability and dose uniformity targets of the IMPELA family. Full beam operation of the IMPELA 10/50 is scheduled for early 1989. (orig.)

  15. Comparison of radioimmunotherapy and external beam radiotherapy in colon cancer xenografts

    International Nuclear Information System (INIS)

    Buras, R.R.; Wong, J.F.C.; Kuhn, J.A.; Beatty, B.G.; Williams, L.E.; Beatty, J.D.; Wanek, P.M.

    1993-01-01

    Radioimmunotherapy and external beam radiotherapy were compared in a nude mouse human colon cancer model. Radioimmunotherapy was delivered by intraperitoneal injection of 90 Y-labeled anticarcinoembryonic antigen monoclonal antibody (anti-CEA MAB). Single fraction external beam radiotherapy was delivered using a 60 Co teletherapy unit. Control groups received saline, unlabeled anit-CEA monoclonal antibody and labeled nonspecific monoclonal antibody. Tumor growth suppression was expressed as delay to reach 2g compared to saline controls. Unlabeled anti-CEA monoclonal antibody and labeled nonspecific monoclonal antibody had no effect. External beam radiotherapy of 300, 600, 1000 and 2000 cGy produced growth delays of 3, 12, 17, and 22 days, respectively. Radioimmunotherapy with 120 μCi, 175 μCi, and 225 μCi resulted in growth delays of 20, 34, and 36 days. Estimated absorbed tumor dose was 1750 cGy in the 120 μCi group. Similar comparisons were done with the more radioresistant WiDr human colon carcinoma cell line. External beam radiotherapy doses of 400, 800, 1200, and 1600 cGy resulted in growth delays of 6, 21, 36 and 48 days, respectively. Radioimmunotherapy of 120 μCi and 175 μCi resulted in growth delays of 9 and 19 days, respectively. The 120 μCi dose delivered an estimated absorbed tumor dose of 1080 cGy to WiDr tumors. In summary, for the radiosensitive LS174T line, radioimmunotherapy produced biologic effects that were comparable to a similar dose of single fraction external beam radiotherapy. For the more radioresistant WiDr tumor, radioimmunotherapy produced a biologic effect which was less than a similar dose of single fraction external beam radiotherapy. These studies suggest that a tumor's response to radioimmunotherapy relative to that of external beam radiotherapy is, in part, dependent on tumor radiosensitivity and repair capacity. 23 refs., 5 figs. 4 tabs

  16. A simple electron-beam lithography system

    International Nuclear Information System (INIS)

    Moelhave, Kristian; Madsen, Dorte Noergaard; Boeggild, Peter

    2005-01-01

    A large number of applications of electron-beam lithography (EBL) systems in nanotechnology have been demonstrated in recent years. In this paper we present a simple and general-purpose EBL system constructed by insertion of an electrostatic deflector plate system at the electron-beam exit of the column of a scanning electron microscope (SEM). The system can easily be mounted on most standard SEM systems. The tested setup allows an area of up to about 50x50 μm to be scanned, if the upper limit for acceptable reduction of the SEM resolution is set to 10 nm. We demonstrate how the EBL system can be used to write three-dimensional nanostructures by electron-beam deposition

  17. Electron beam damage in oxides: a review.

    Science.gov (United States)

    Jiang, Nan

    2016-01-01

    This review summarizes a variety of beam damage phenomena relating to oxides in (scanning) transmission electron microscopes, and underlines the shortcomings of currently popular mechanisms. These phenomena include mass loss, valence state reduction, phase decomposition, precipitation, gas bubble formation, phase transformation, amorphization and crystallization. Moreover, beam damage is also dependent on specimen thickness, specimen orientation, beam voltage, beam current density and beam size. This article incorporates all of these damage phenomena and experimental dependences into a general description, interpreted by a unified mechanism of damage by induced electric field. The induced electric field is produced by positive charges, which are generated from excitation and ionization. The distribution of the induced electric fields inside a specimen is beam-illumination- and specimen-shape- dependent, and associated with the experimental dependence of beam damage. Broadly speaking, the mechanism operates differently in two types of material. In type I, damage increases the resistivity of the irradiated materials, and is thus divergent, resulting in phase separation. In type II, damage reduces the resistivity of the irradiated materials, and is thus convergent, resulting in phase transformation. Damage by this mechanism is dependent on electron-beam current density. The two experimental thresholds are current density and irradiation time. The mechanism comes into effect when these thresholds are exceeded, below which the conventional mechanisms of knock-on and radiolysis still dominate.

  18. Modular low-voltage electron beams

    International Nuclear Information System (INIS)

    Berejka, A.J.; Avnery, Tovi; Carlson, Carl

    2004-01-01

    Modular, low-voltage systems have simplified electron beam (EB) technology for industrial uses and for research and development. Modular EB units are produced in quantity as sealed systems that are evacuated at the factory eliminating the need for vacuum pumps at the point of use. A simple plug-out--plug-in method of replacement eliminates downtime for servicing. Use of ultra-thin beam windows (<10 μm of titanium foil), solid-state 19 in. (48 cm) rack-mounted power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, combine for ease of use and electrical transfer efficiency at voltages that can be varied between 80 and 150 kV and with high beam currents (up to 40 mA across the 25 cm window). These electron systems are available in three widths, the standard 25 cm and new 5 and 40 cm beams. Traditional uses in the graphic arts and coatings areas as well as uses in surface sterilization have found these compact, lightweight (approximately 15 kg) modular beams of interest. Units have been configured around complex shapes to enable three-dimensional surface curing (as for coatings on aluminum tubing) to be achieved at high production rates. Details of the beam construction and some industrial uses are discussed

  19. Modular low-voltage electron beams

    Science.gov (United States)

    Berejka, Anthony J.; Avnery, Tovi; Carlson, Carl

    2004-09-01

    Modular, low-voltage systems have simplified electron beam (EB) technology for industrial uses and for research and development. Modular EB units are produced in quantity as sealed systems that are evacuated at the factory eliminating the need for vacuum pumps at the point of use. A simple plug-out—plug-in method of replacement eliminates downtime for servicing. Use of ultra-thin beam windows (innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, combine for ease of use and electrical transfer efficiency at voltages that can be varied between 80 and 150 kV and with high beam currents (up to 40 mA across the 25 cm window). These electron systems are available in three widths, the standard 25 cm and new 5 and 40 cm beams. Traditional uses in the graphic arts and coatings areas as well as uses in surface sterilization have found these compact, lightweight (approximately 15 kg) modular beams of interest. Units have been configured around complex shapes to enable three-dimensional surface curing (as for coatings on aluminum tubing) to be achieved at high production rates. Details of the beam construction and some industrial uses are discussed.

  20. High-brightness electron beam diagnostics at the ATF

    International Nuclear Information System (INIS)

    Wang, X.J.; Ben-Zvi, I.

    1996-01-01

    The Brookhaven Accelerator Test Facility (ATF) is a dedicated user facility for accelerator physicists. Its design is optimized to explore laser acceleration and coherent radiation production. To characterize the low-emittance, picoseconds long electron beam produced by the ATF's photocathode RF gun, we have installed electron beam profile monitors for transverse emittance measurement, and developed a new technique to measure electron beam pulse length by chirping the electron beam energy. We have also developed a new technique to measure the ps slice emittance of a 10 ps long electron beam. Stripline beam position monitors were installed along the beam to monitor the electron beam position and intensity. A stripline beam position monitor was also used to monitor the timing jitter between the RF system and laser pulses. Transition radiation was used to measure electron beam energy, beam profile and electron beam bunch length

  1. Development of multileaf collimator- and compensator-based techniques for modulated electron radiotherapy

    Science.gov (United States)

    Tynan, Patricia Marie

    Modulated electron radiotherapy (MERT) is a new electron therapy technique that uses intensity- and/or energy-modulated electron beams to provide a highly conformal dose of radiation to the treatment volume with low levels of dose deposition outside the treatment volume. Several methods are under investigation for treatment of patients, including the use of photon multileaf collimator-modulated (pMLC-modulated) beams, add-on electron multileaf collimators, and carved bolus materials placed directly on the patient's skin. This project developed a new method of delivering MERT beams using patient-specific milled compensators mounted in the standard electron applicator of a linear accelerator, accomplished through four specific aims. Aim 1: Conduct a feasibility study regarding the application of pMLC- and compensator-based MERT techniques within the clinic. Aim 2: Develop a software system to design compensators for modulated electron radiotherapy. Using MATLAB, an automated process for extracting treatment volume location data from a patient's CT data set was created. This software provides data about the depth to which the compensator must be machined to provide a conformal dose to the tumor. Aim 3: Use the Monte Carlo codes BEAMnrc and DOSXYZnrc to commission electron beams of a Varian 23EX linear accelerator for subsequent use in MERT treatment planning. A 10 cm x 10 cm field was modeled for three different energies (9, 12, and 16 MeV) for a Varian 23EX linear accelerator. Excellent match of the models to physical data was achieved, with less than 2% difference in dose and less than 2 mm difference in the lateral dimensions for the beam profiles. Aim 4: Create and validate a compensator-based MERT treatment plan. Using the coordinate data provided by the program created in Aim 3, a treatment plan was developed using the Monte Carlo code MCSIM for a simulated treatment volume. The resulting plan was manually optimized, resulting in a final dosimetric distribution

  2. External Beam Radiotherapy for Colon Cancer: Patterns of Care

    International Nuclear Information System (INIS)

    Dunn, Emily F.; Kozak, Kevin R.; Moody, John S.

    2010-01-01

    Purpose: Despite its common and well characterized use in other gastrointestinal malignancies, little is known about radiotherapy (RT) use in nonmetastatic colon cancer in the United States. To address the paucity of data regarding RT use in colon cancer management, we examined the RT patterns of care in this patient population. Methods and Materials: Patients with nonmetastatic colon cancer, diagnosed between 1988 and 2005, were identified in the Surveillance, Epidemiology, and End Results (SEER) database. Univariate and multivariate methods were used to identify factors associated with RT use. Results: On univariate analysis, tumor location, age, sex, race, T stage, N stage, and geographic location were each associated with differences in RT use (all p < 0.01). In general, younger patients, male patients, and patients with more advanced disease were more likely to receive RT. On multivariate analysis, tumor location, age, gender, T and N stage, time of diagnosis and geographic location were significantly associated with RT use (all p < 0.001). Race, however, was not associated with RT use. On multivariate analysis, patients diagnosed in 1988 were 2.5 times more likely to receive RT than those diagnosed in 2005 (p = 0.001). Temporal changes in RT use reflect a responsiveness to evolving evidence related to the therapeutic benefits of adjuvant RT. Conclusions: External beam RT is infrequently used for colon cancer, and its use varies according to patient and tumor characteristics. RT use has declined markedly since the late 1980s; however, it continues to be used for nonmetastatic disease in a highly individualized manner.

  3. Electron beam curable polymer thick film

    International Nuclear Information System (INIS)

    Nagata, Hidetoshi; Kobayashi, Takashi

    1988-01-01

    Currently, most printed circuit boards are produced by the selective etching of copper clads laminated on dielectric substrates such as paper/phenolic resion or nonwoven glass/epoxy resin composites. After the etchig, various components such as transistors and capacitors are mounted on the boards by soldering. But these are troublesome works, therefore, as an alternative, printing method has been investigated recently. In the printing method, conductor circuits and resistors can be made by printing and curing of the specially prepared paste on dielectric substrates. In the near future, also capacitors are made by same method. Usually, conductor paste, resistor paste and dielectric paste are employed, and in this case, the printing is screen printing, and the curing is done thermally. In order to avoid heating and the deterioration of substrates, attention was paid to electron beam curing, and electron beam curable polymer thick film system was developed. The electron beam curable paste is the milled mixture of a filler and an electron beam curable binder of oligomer/monomer. The major advantage of electron beam curable polymer thick film, the typical data of a printed resistor of this type and its trial are reported. (K.I.)

  4. Hansan ramie fibers irradiated by electron beam

    International Nuclear Information System (INIS)

    Choi, Haeyoung; Lee, Jeong Sun

    2010-01-01

    Material is inexpensive, abundant Light weight: fuel efficient Environment: Co 2 reduction, renewable Performance: acceptable Spec. But it is variability, Irregular hollow fiber shape, limited planting counting Environment: odor, degradation of mechanical properties Performance: poor fiber-matrix bonding, water absorption, difficulty in quality control. Hansan ramie fibers were irradiated by electron beam to make surface modification for better bonding in the manufacture of composite. EB irradiation on cellulose changed the surface morphology property. - Impurities on the surface of ramie and lignin were removed by electron beam irradiation. The electron beam irradiation with high energy reduced α-cellulose and increased β-cellulose. - The reduction of α-cellulose indicates the degradation of cellulose chain, which usually lead to decrease of fiber strength properties. When ramie fibers were irradiated by electron beam with 3kGy, α-cellulose was not decreased significantly and the impurity and lignin were separated from the ramie fiber. The best mechanical properties were obtained when ramie fibers were obtained when ramie fibers were irradiated by electron beam with 3kGy

  5. Multi-electron beam system for high resolution electron beam induced deposition

    NARCIS (Netherlands)

    Van Bruggen, M.J.

    2008-01-01

    The development of a multi-electron beam system is described which is dedicated for electron beam induced deposition (EBID) with sub-10 nm resolution. EBID is a promising mask-less nanolithography technique which has the potential to become a viable technique for the fabrication of 20-2 nm

  6. Nonlinear evolution of the auroral electron beam

    Science.gov (United States)

    Maggs, James E.

    1989-01-01

    The nonlinear spatial evolution, from the source to the atmosphere, of the auroral electron beam and the beam-generated electrostatic whistler noise was studied, calculating changes in beam parameters from equations for the conservation of total particle and wave energy and momentum flux density. Wave power fluxes were calculated by numerically integrating the wave kinetic equations, and the levels of beam-generated noise were determined by using thermal levels of Cerenkov radiation as a source. It was found that beam parameters evolve on ionospheric scale lengths, and their positive slope feature in velocity space is maintained over altitudes measured in thousands of kilometers of altitude, even though they can generate wave energy density fluxes sufficient to modify the ionospheric density profile.

  7. Foil focusing of relativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Jr., Carl August [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-26

    When an intense relativistic electron beams (IREB) passes through a grounded metal foil, the transverse electric field due to the beam space charge is locally shorted out, and the beam is focused by the magnetic field of its current. The effect can be treated as focusing by a thin lens with first order aberration. Expressions for the focal length and aberration coefficient of the equivalent thin lens are developed in this note. These are then applied to practical examples representative of IREB research at Los Alamos National Laboratory.

  8. Electron Beam Propagation in a Plasma

    Directory of Open Access Journals (Sweden)

    Kyoung W. Min

    1988-06-01

    Full Text Available Electron beam propagation in a fully ionized plasma has been studied using a one-dimensional particle simulation model. We compare the results of electrostatic simulations to those of electromagnetic simulations. The electrostatic results show the essential features of beam-plasma instability which accelerates ambient plasmas. The results also show the heating of ambient plasmas and the trapping of plasmas due to the locally generated electric field. The level of the radiation generated by the same non-relativistic beam is slightly higher than the noise level. We discuss the results in context of the heating of coronal plasma during solar flares.

  9. Prostate image-guided radiotherapy by megavolt cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Zucca, Sergio; Carau, Barbara; Solla, Ignazio; Garibaldi, Elisabetta; Farace, Paolo; Lay, Giancarlo; Meleddu, Gianfranco; Gabriele, Pietro [Regional Oncological Hospital, Cagliari (Italy). Dept. of Radiooncology

    2011-08-15

    To test megavolt cone-beam CT (MV-CBCT) in order to evaluate setup errors in prostate radiotherapy. The setup of 9 patients was verified weekly by electronic portal imaging (EPI) and MV-CBCT, both performed in the same treatment session. EPI were compared with digitally reconstructed radiographies (DRRs). MV-CBCTs were matched to simulation CTs by manual registration based on bone markers (BMR), by manual registration based on soft tissues (STR) - rectum, bladder, and seminal vesicles - and by automatic registration (AR) performed by a mutual information algorithm. Shifts were evaluated along the three main axes: anteroposterior (AP), craniocaudal (CC), and laterolateral (LL). Finally, in 4 additional patients showing intraprostatic calcifications, the calcification mismatch error was used to evaluate the three MV-CBCT matching methods. A total of 50 pairs of orthogonal EPIs and 50 MV-CBCTs were analyzed. Assuming an overall tolerance of 2 mm, no significant differences were observed comparing EPI vs BMR in any axis. A significant difference (p < 0.001) was observed along the AP axis comparing EPI vs AR and EPI vs STR. On the calcification data set (22 measures), the calcification mismatch along the AP direction was significantly lower (p < 0.05) after STR than after BMR or AR. Bone markers were not an effective surrogate of the target position and significant differences were observed comparing EPI or BMR vs STR, supporting the assessment of soft tissue position by MVCBs to verify and correct patient setup in prostate radiotherapy. (orig.)

  10. Prostate image-guided radiotherapy by megavolt cone-beam CT

    International Nuclear Information System (INIS)

    Zucca, Sergio; Carau, Barbara; Solla, Ignazio; Garibaldi, Elisabetta; Farace, Paolo; Lay, Giancarlo; Meleddu, Gianfranco; Gabriele, Pietro

    2011-01-01

    To test megavolt cone-beam CT (MV-CBCT) in order to evaluate setup errors in prostate radiotherapy. The setup of 9 patients was verified weekly by electronic portal imaging (EPI) and MV-CBCT, both performed in the same treatment session. EPI were compared with digitally reconstructed radiographies (DRRs). MV-CBCTs were matched to simulation CTs by manual registration based on bone markers (BMR), by manual registration based on soft tissues (STR) - rectum, bladder, and seminal vesicles - and by automatic registration (AR) performed by a mutual information algorithm. Shifts were evaluated along the three main axes: anteroposterior (AP), craniocaudal (CC), and laterolateral (LL). Finally, in 4 additional patients showing intraprostatic calcifications, the calcification mismatch error was used to evaluate the three MV-CBCT matching methods. A total of 50 pairs of orthogonal EPIs and 50 MV-CBCTs were analyzed. Assuming an overall tolerance of 2 mm, no significant differences were observed comparing EPI vs BMR in any axis. A significant difference (p < 0.001) was observed along the AP axis comparing EPI vs AR and EPI vs STR. On the calcification data set (22 measures), the calcification mismatch along the AP direction was significantly lower (p < 0.05) after STR than after BMR or AR. Bone markers were not an effective surrogate of the target position and significant differences were observed comparing EPI or BMR vs STR, supporting the assessment of soft tissue position by MVCBs to verify and correct patient setup in prostate radiotherapy. (orig.)

  11. EPR dosimetry of radiotherapy photon beams in inhomogeneous media using alanine films

    International Nuclear Information System (INIS)

    Oesteraas, Bjoern Helge; Hole, Eli Olaug; Olsen, Dag Rune; Malinen, Eirik

    2006-01-01

    In the current work, EPR (electron paramagnetic resonance) dosimetry using alanine films (134 μm thick) was utilized for dose measurements in inhomogeneous phantoms irradiated with radiotherapy photon beams. The main phantom material was PMMA, while either Styrofoam or aluminium was introduced as an inhomogeneity. The phantoms were irradiated to a maximum dose of about 30 Gy with 6 or 15 MV photons. The performance of the alanine film dosimeters was investigated and compared to results from ion chamber dosimetry, Monte Carlo simulations and radiotherapy treatment planning calculations. It was found that the alanine film dosimeters had a linear dose response above approximately 5 Gy, while a background signal obscured the response at lower dose levels. For doses between 5 and 60 Gy, the standard deviation of single alanine film dose estimates was about 2%. The alanine film dose estimates yielded results comparable to those from the Monte Carlo simulations and the ion chamber measurements, with absolute differences between estimates in the order of 1-15%. The treatment planning calculations exhibited limited applicability. The current work shows that alanine film dosimetry is a method suitable for estimating radiotherapeutical doses and for dose measurements in inhomogeneous media

  12. Beam profile for Malaysian electron accelerator

    International Nuclear Information System (INIS)

    Abu Bakar Ghazali; Muhamad Zahidee Taat

    2007-01-01

    This paper comprises of two calculations that require in designing a dose profile for an electron accelerator machine before its fabrication. The first is to calculate the beam deflection due to changes of high voltage (HV) supply as well as the deflection coil currents so that the electron beam will only scan at the window foil of 18 cm length and 6 cm width. Secondly, we also require to calculate the beam profile at 50 mm underneath the window foil. The electron gun that produces a beam of 10 mm diameter has to be oscillated in a sawtooth wave for the prescribed window size at frequencies of 50 Hz and 400 Hz along the length and width directions respectively. For the beam deflection, we apply a basic formula from Lorentz force law to obtain a set of HV supply and the coil current that is suitable for both deflections and this result can assist in designing the coil current against HV changes via an electronic controller. The dose profile was calculated using the RMS current formulation along the length direction. We found that the measured and the calculated RMS currents are in comparable for the case of 1 MeV, 50 mA accelerator facility that is going to be installed at Nuclear Malaysia complex. A similar measurement will be carried out for our locally designed accelerator of 150 KeV, 10 mA after fabrication and installation of the machine are completed. (Author)

  13. Spot-scanning beam delivery with laterally- and longitudinally-mixed spot size pencil beams in heavy ion radiotherapy

    Science.gov (United States)

    Yan, Yuan-Lin; Liu, Xin-Guo; Dai, Zhong-Ying; Ma, Yuan-Yuan; He, Peng-Bo; Shen, Guo-Sheng; Ji, Teng-Fei; Zhang, Hui; Li, Qiang

    2017-09-01

    The three-dimensional (3D) spot-scanning method is one of the most commonly used irradiation methods in charged particle beam radiotherapy. Generally, spot-scanning beam delivery utilizes the same size pencil beam to irradiate the tumor targets. Here we propose a spot-scanning beam delivery method with laterally- and longitudinally-mixed size pencil beams for heavy ion radiotherapy. This uses pencil beams with a bigger spot size in the lateral direction and wider mini spread-out Bragg peak (mini-SOBP) to irradiate the inner part of a target volume, and pencil beams with a smaller spot size in the lateral direction and narrower mini-SOBP to irradiate the peripheral part of the target volume. Instead of being controlled by the accelerator, the lateral size of the pencil beam was adjusted by inserting Ta scatterers in the beam delivery line. The longitudinal size of the pencil beam (i.e. the width of the mini-SOBP) was adjusted by tilting mini ridge filters along the beam direction. The new spot-scanning beam delivery using carbon ions was investigated theoretically and compared with traditional spot-scanning beam delivery. Our results show that the new spot-scanning beam delivery has smaller lateral penumbra, steeper distal dose fall-off and the dose homogeneity (1-standard deviation/mean) in the target volume is better than 95%. Supported by Key Project of National Natural Science Foundation of China (U1232207), National Key Technology Support Program of the Ministry of Science and Technology of China (2015BAI01B11), National Key Research and Development Program of the Ministry of Science and Technology of China (2016YFC0904602) and National Natural Science Foundation of China (11075191, 11205217, 11475231, 11505249)

  14. Successful Electron Beam Recirculation Test for Fermilab Electron Cooling

    Science.gov (United States)

    Nagaitsev, Sergei; Crawford, A. Curtis; Sharapa, Anatoly; Shemyakin, Alexander

    1998-04-01

    In this paper we describe the successful operation of a dc recirculation electron beam system at energies 1 -- 1.5 MeV and currents in excess of 200 mA. This system employs an electrostatic HV supply like a Van de Graaff generator with maximum charging current of a few hundred microamps. Electron beam line consits of a 10 m long channel with discrete focusing elements flanked by high-gradient (10 kV/cm), small aperture (2.54 cm ID) acceleraton and deceleration tubes. This work is performed as part of the Fermilab R&D program to develop electron cooling for 8 GeV antiprotons.

  15. Development of electron beam deflection circuit

    International Nuclear Information System (INIS)

    Leo Kwee Wah; Lojius Lombigit; Abu Bakar Ghazali; Azaman

    2007-01-01

    This paper describes a development of a power supply circuit to deflect and move the electron beam across the window of the Baby electron beam machine. It comprises a discussion of circuit design, its assembly and the test results. A variety of input and output conditions have been tested and it was found that the design is capable to supply 1.0 A with 50Hz on X-axis coil and 0.4A with 500Hz on Y-axis coil. (Author)

  16. Electron beam damage in high temperature polymers

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S. (Dayton Univ., OH (USA). Research Inst.); Adams, W.W. (Air Force Materials Lab., Wright-Patterson AFB, OH (USA))

    1990-01-01

    Electron microscopic studies of polymers are limited due to beam damage. Two concerns are the damage mechanism in a particular material, and the maximum dose for a material before damage effects are observed. From the knowledge of the dose required for damage to the polymer structure, optimum parameters for electron microscopy imaging can be determined. In the present study, electron beam damage of polymers has been quantified by monitoring changes in the diffraction intensity as a function of electron dose. The beam damage characteristics of the following polymers were studied: poly(p-phenylene benzobisthiazole) (PBZT); poly(p-phenylene benzobisoxazole) (PBO); poly(benzoxazole) (ABPBO); poly(benzimidazole) (ABPBI); poly(p-phenylene terephthalamide) (PPTA); and poly(aryl ether ether ketone) (PEEK). Previously published literature results on polyethylene (PE), polyoxymethylene (POM), nylon-6, poly(ethylene oxide) (PEO), PBZT, PPTA, PPX, iPS, poly(butylene terephthalate) (PBT), and poly(phenylene sulphide) (PPS) were reviewed. This study demonstrates the strong dependence of the electron beam resistivity of a polymer on its thermal stability/melt temperature. (author).

  17. European developments in radiotherapy with beams of large radiobiological effectiveness.

    Science.gov (United States)

    Amaldi, Ugo; Kraft, Gerhard

    2007-01-01

    This paper reviews the European activities in the field of tumour therapy with beams which have a Radio Biological Effectiveness (RBE) larger than 1. Initially neutron beams have been used. Then charged pions promised better cure rates so that their use was pursued in the framework of the ;Piotron' project at the Paul Scherrer Institute (Switzerland). However both approaches did not meet the expectations and in the 80s the EULIMA project became the flagship of these attempts to improve the effects of the delivery of radiation doses of large RBE with respect to photons, electrons and even protons. The EULIMA ion accelerator was never built and it took more than ten years to see the approval, in Heidelberg and Pavia, of the construction of the HIT and CNAO ;dual' centres for carbon ions and protons. In 2008 they will start treating patients. The developments that brought to these construction projects are described together with the special features of these two facilities. The third European dual centre is being built by Siemens Medical Systems in Marburg, Germany, while other facilities have been approved but not yet fully financed in Wiener Neustadt (Austria), Lyon (France) and Uppsala (Sweden). Finally the collaboration activities of the European Network ENLIGHT are presented together with the recent involvements of European industries in the construction of turn-key dual centres and the development of a new accelerator concept for hadrontherapy, the ;cyclinac'.

  18. Solid waste electron beam treatment

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1998-01-01

    The possible applications of electron accelerators for solid waste treatment are discussed in the report. The elaborated technologies allow to recycle of materials (e.g. cellulosic materials in municipal waste), improve their hygienic standards (agricultural usage of sludge from municipal waste water treatment) and reduce harmful to environment chemical usage (cellulose degradation). These are environment friendly advanced technologies which meets demands waste recycling. (author)

  19. Characterizing a pulse-resolved dosimetry system for complex radiotherapy beams using organic scintillators

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Ottosson, Rickard; Lindvold, Lars René

    2011-01-01

    A fast-readout dosimetry system based on fibre-coupled organic scintillators has been developed for the purpose of conducting point measurements of absorbed dose in radiotherapy beams involving high spatial and temporal dose gradients. The system measures the dose for each linac radiation pulse w...... and quality assurance of complex radiotherapy treatments.......A fast-readout dosimetry system based on fibre-coupled organic scintillators has been developed for the purpose of conducting point measurements of absorbed dose in radiotherapy beams involving high spatial and temporal dose gradients. The system measures the dose for each linac radiation pulse....... No significant differences between measurements and simulations were observed. The temporal resolution of the system was demonstrated by measuring dose per pulse, beam start-up transients and the quality factor for 6 MV. The precision of dose per pulse measurements was within 2.7% (1 SD) for a 10 cm × 10 cm...

  20. Gamma Putty dosimetric studies in electron beam

    Directory of Open Access Journals (Sweden)

    Aime M Gloi

    2016-01-01

    Full Text Available Traditionally, lead has been used for field shaping in megavoltage electron beams in radiation therapy. In this study, we analyze the dosimetric parameters of a nontoxic, high atomic number (Z = 83, bismuth-loaded material called Gamma Putty that is malleable and can be easily molded to any desired shape. First, we placed an ionization chamber at different depths in a solid water phantom under a Gamma Putty shield of thickness (t = 0, 3, 5, 10, 15, 20, and 25 mm, respectively and measured the ionizing radiation on the central axis (CAX for electron beam ranging in energies from 6 to 20 MeV. Next, we investigated the relationship between the relative ionization (RI measured at a fixed depth for several Gamma Putty shield at different cutout diameters ranging from 2 to 5 cm for various beam energies and derived an exponential fitting equation for clinical purposes. The dose profiles along the CAX show that bremsstrahlung dominates for Gamma Putty thickness >15 mm. For high-energy beams (12-20 MeV and all Gamma Putty thicknesses up to 25 mm, RI below 5% could not be achieved due to the strong bremsstrahlung component. However, Gamma Putty is a very suitable material for reducing the transmission factor below 5% and protecting underlying normal tissues for low-energy electron beams (6-9 MeV.

  1. Electron Density Calibration for Radiotherapy Treatment Planning

    International Nuclear Information System (INIS)

    Herrera-Martinez, F.; Rodriguez-Villafuerte, M.; Martinez-Davalos, A.; Ruiz-Trejo, C.; Celis-Lopez, M. A.; Larraga-Gutierrez, J. M.; Garcia-Garduno, A.

    2006-01-01

    Computed tomography (CT) images are used as basic input data for most modern radiosurgery treatment planning systems (TPS). CT data not only provide anatomic information to delineate target volumes, but also allow the introduction of corrections for tissue inhomogeneities into dose calculations during the treatment planning procedure. These corrections involve the determination of a relationship between tissue electron density (ρe) and their corresponding Hounsfield Units (HU). In this work, an elemental analysis of different commercial tissue equivalent materials using Scanning Electron Microscopy was carried out to characterize their chemical composition. The tissue equivalent materials were chosen to ensure a large range of ρe to be included in the CT scanner calibration. A phantom was designed and constructed with these materials to simulate the size of a human head

  2. Electron cloud effects in hadron beams

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Fedor; Boine-Frankenheim, Oliver; Weiland, Thomas [TU-Darmstadt, Institut fuer Theorie Elektromagnetischer Felder,Schlossgartenstr. 8 64289 Darmstadt (Germany)

    2013-07-01

    Accelerators operating with intense positively charged beams can suffer from the electron cloud phenomenon. For example, it is the intensity limiting factor in CERN LHC and SPS. In past decades a lot of progress in understanding the electron cloud effects was made worldwide. Methods to suppress or weaken the electron cloud phenomenon were proposed. Theories governing the bunch stability in presence of the electron cloud were developed. Recently the theory was introduced to describe the bunch energy loss due to the electron cloud. However, most of the publications concern the single bunch electron cloud effects. In reality bunches are packed into trains. A disturbance of the cloud caused by the bunch in the beginning of the train affects the subsequent bunches. We present a further investigation of single-bunch electron cloud effects and planned activities to study the phenomenon in case of multiple bunches.

  3. Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

    International Nuclear Information System (INIS)

    Bravim, Amanda

    2010-01-01

    The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO 4 : Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60 Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO 4 : Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments. (author)

  4. Dosimetry for Electron Beam Applications

    DEFF Research Database (Denmark)

    Miller, Arne

    1983-01-01

    This report describes two aspects of electron bean dosimetry, on one hand developaent of thin fil« dosimeters and measurements of their properties, and on the other hand developaent of calorimeters for calibration of routine dosimeters, e.g. thin films. Two types of radiochromic thin film...... dosimeters have been developed in this department, and the properties of these and commercially available dosimeters have been measured and found to be comparable. Calorimeters, which are in use for routine measurements, are being investigated with reference to their application as standardizing instruments......, and new calorimeters are being developed....

  5. Radiative cooling of relativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhirong [Stanford Univ., CA (United States)

    1998-05-01

    Modern high-energy particle accelerators and synchrotron light sources demand smaller and smaller beam emittances in order to achieve higher luminosity or better brightness. For light particles such as electrons and positrons, radiation damping is a natural and effective way to obtain low emittance beams. However, the quantum aspect of radiation introduces random noise into the damped beams, yielding equilibrium emittances which depend upon the design of a specific machine. In this dissertation, the author attempts to make a complete analysis of the process of radiation damping and quantum excitation in various accelerator systems, such as bending magnets, focusing channels and laser fields. Because radiation is formed over a finite time and emitted in quanta of discrete energies, he invokes the quantum mechanical approach whenever the quasiclassical picture of radiation is insufficient. He shows that radiation damping in a focusing system is fundamentally different from that in a bending system. Quantum excitation to the transverse dimensions is absent in a straight, continuous focusing channel, and is exponentially suppressed in a focusing-dominated ring. Thus, the transverse normalized emittances in such systems can in principle be damped to the Compton wavelength of the electron, limited only by the Heisenberg uncertainty principle. In addition, he investigates methods of rapid damping such as radiative laser cooling. He proposes a laser-electron storage ring (LESR) where the electron beam in a compact storage ring repetitively interacts with an intense laser pulse stored in an optical resonator. The laser-electron interaction gives rise to rapid cooling of electron beams and can be used to overcome the space charge effects encountered in a medium energy circular machine. Applications to the designs of low emittance damping rings and compact x-ray sources are also explored.

  6. Longitudinal Diagnostics for Short Electron Beam Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Loos, H.; /SLAC

    2010-06-11

    Single-pass free electron lasers require high peak currents from ultra-short electron bunches to reach saturation and an accurate measurement of bunch length and longitudinal bunch profile is necessary to control the bunch compression process from low to high beam energy. The various state-of-the-art diagnostics methods from ps to fs time scales using coherent radiation detection, RF deflection, and other techniques are presented. The use of linear accelerators as drivers for free electron lasers (FEL) and the advent of single-pass (SASE) FELs has driven the development of a wide range of diagnostic techniques for measuring the length and longitudinal distribution of short and ultra-short electron bunches. For SASE FELs the radiation power and the length of the undulator needed to achieve saturation depend strongly on the charge density of the electron beam. In the case of X-ray FELs, this requires the accelerator to produce ultra-high brightness beams with micron size transverse normalized emittances and peak currents of several kA through several stages of magnetic bunch compression. Different longitudinal diagnostics are employed to measure the peak current and bunch profile along these stages. The measurement techniques can be distinguished into different classes. Coherent methods detect the light emitted from the beam by some coherent radiation process (spectroscopic measurement), or directly measure the Coulomb field traveling with the beam (electro-optic). Phase space manipulation techniques map the time coordinate onto a transverse dimension and then use conventional transverse beam diagnostics (transverse deflector, rf zero-phasing). Further methods measure the profile or duration of an incoherent light pulse emitted by the bunch at wavelengths much shorted than the bunch length (streak camera, fluctuation technique) or modulate the electron beam at an optical wavelength and then generate a narrow bandwidth radiation pulse with the longitudinal profile of

  7. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  8. Electron beam welding fundamentals and applications

    International Nuclear Information System (INIS)

    Mara, G.L.; Armstrong, R.E.

    1975-01-01

    The electron beam welding process is described and the unique mode of operation and penetration explained by a description of the forces operating within the weld pool. This penetration model is demonstrated by high speed cinematography of the weld pool on several materials. The conditions under which weld defects are formed are discussed and examples are presented. (auth)

  9. Economy in utilizing electron beam accelerators

    International Nuclear Information System (INIS)

    Takahashi, Masao

    1980-01-01

    As the typical industrialized processes using electron beam irradiation, the following items may be given: the manufacture of cables covered with cross-linking polyethylene or PVC, heat-contracting material, cross-linking polyethylene foam, etc., and the curing of coatings or surface finishes. The results of investigating economy in these processes are described. First, the running cost of electron beam irradiation equipments is calculated. The result shows that, in general, the unit cost of the equipments becomes small with increasing output, therefore the selection of large power equipments may be advantageous for economy. Other important factors concerning the equipments are the reliability and lifetime which are being improved every year and the improvement of the operational efficiency of the equipments. Next, the comparison of cost was made for each industrialized process of the cables covered with cross-linking polyethylene, polyethylene foam, and the curing of coatings. In general, the processing cost is smaller and the depreciation cost is larger in electron beam irradiation process as compared with conventional processes. In addition, since the productive capacity is larger in electron beam process it is preponderant when the amount of production is large. In the industrialized examples, unique processes or features which are not obtainable by other methods are attained. (Wakatsuki, Y.)

  10. The CMS Beam Halo Monitor electronics

    International Nuclear Information System (INIS)

    Tosi, N.; Fabbri, F.; Montanari, A.; Torromeo, G.; Dabrowski, A.E.; Orfanelli, S.; Grassi, T.; Hughes, E.; Mans, J.; Rusack, R.; Stifter, K.; Stickland, D.P.

    2016-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes (PMTs). The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few nanosecond resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is read out via IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providing online feedback on the beam quality. A dedicated calibration monitoring system has been designed to generate short triggered pulses of light to monitor the efficiency of the system. The electronics has been in operation since the first LHC beams of Run II and has served as the first demonstration of the new QIE10, Microsemi Igloo2 FPGA and high-speed 5 Gbps link with LHC data

  11. Electron beam flue gas treatment process. Review

    International Nuclear Information System (INIS)

    Honkonen, V.A.

    1996-01-01

    The basis of the process for electron beam flue gas treatment are presented in the report. In tabular form the history of the research is reviewed. Main dependences of SO 2 and NO x removal efficiencies on different physico-chemical parameters are discussed. Trends concerning industrial process implementation are presented in the paper,finally. (author). 74 refs, 11 figs, 1 tab

  12. The CMS Beam Halo Monitor electronics

    Science.gov (United States)

    Tosi, N.; Dabrowski, A. E.; Fabbri, F.; Grassi, T.; Hughes, E.; Mans, J.; Montanari, A.; Orfanelli, S.; Rusack, R.; Torromeo, G.; Stickland, D. P.; Stifter, K.

    2016-02-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes (PMTs). The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few nanosecond resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is read out via IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providing online feedback on the beam quality. A dedicated calibration monitoring system has been designed to generate short triggered pulses of light to monitor the efficiency of the system. The electronics has been in operation since the first LHC beams of Run II and has served as the first demonstration of the new QIE10, Microsemi Igloo2 FPGA and high-speed 5 Gbps link with LHC data.

  13. Electron beam effects on gelatin polymer

    International Nuclear Information System (INIS)

    Inamura, Patricia Y.; Shimazaki, Kleber; Souza, Clecia de M.; Moura, Esperidiana A.B.; Mastro, Nelida L. del; Colombo, Maria A.

    2009-01-01

    The main field of electron-beam radiation processing applications is the modification of polymeric material. Polymer development includes new pathways to produce natural polymers with better mechanical and barrier properties and thermal stability. The aim of this paper was to investigate the behavior of a gelatin/acrylamide polymer treated by electron-beam radiation. Gelatin is a heterogeneous mixture of water-soluble proteins of high average molecular mass derived by hydrolytic action from animal collagen, a fibrous insoluble protein, which is widely found in nature as the major constituent of skin, bones and connective tissue. Hydrolyzed collagen is composed of a unique sequence of amino acids, characterized particularly by the high content of glycine, proline and hydroxyproline. Among biomaterials, gelatin is an interesting material because is a partially crystalline polymer and has a relatively low melting point. Samples of gelatin together with glycerin as plasticizer and acrylamide as copolymer were irradiated with doses of 10 kGy and 40 kGy, using an electron beam accelerator, dose rate 22.41kGy/s, at room temperature in presence of air. After irradiation, some preliminary analyses were done like viscometry, texture analyses and colorimetry. The results of the diverse tests showed changes that can be ascribed to radiation-induced crosslinking. The electron-beam processed acrylamide-gelatin polymer using glycerin as plasticizer must be first extensively characterized before to be used for general applications. (author)

  14. Electron beam puts a shine on leather

    International Nuclear Information System (INIS)

    Berberich, S.

    1986-01-01

    A technique for curing leather using either ultraviolet or electron-beam radiation has been developed. This type of radiation curing saves at least 60 percent of the energy cost of conventional leather finishing and can also result in considerable savings in plant space and labor. The implications of the new technology in international balance of trade are discussed

  15. Electron beam effects on gelatin polymer

    Energy Technology Data Exchange (ETDEWEB)

    Inamura, Patricia Y.; Shimazaki, Kleber; Souza, Clecia de M.; Moura, Esperidiana A.B.; Mastro, Nelida L. del, E-mail: patyoko@yahoo.co [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Colombo, Maria A., E-mail: mascolombo@yahoo.com.b [Faculdade de Tecnologia da Zona Leste, Sao Paulo, SP (Brazil)

    2009-07-01

    The main field of electron-beam radiation processing applications is the modification of polymeric material. Polymer development includes new pathways to produce natural polymers with better mechanical and barrier properties and thermal stability. The aim of this paper was to investigate the behavior of a gelatin/acrylamide polymer treated by electron-beam radiation. Gelatin is a heterogeneous mixture of water-soluble proteins of high average molecular mass derived by hydrolytic action from animal collagen, a fibrous insoluble protein, which is widely found in nature as the major constituent of skin, bones and connective tissue. Hydrolyzed collagen is composed of a unique sequence of amino acids, characterized particularly by the high content of glycine, proline and hydroxyproline. Among biomaterials, gelatin is an interesting material because is a partially crystalline polymer and has a relatively low melting point. Samples of gelatin together with glycerin as plasticizer and acrylamide as copolymer were irradiated with doses of 10 kGy and 40 kGy, using an electron beam accelerator, dose rate 22.41kGy/s, at room temperature in presence of air. After irradiation, some preliminary analyses were done like viscometry, texture analyses and colorimetry. The results of the diverse tests showed changes that can be ascribed to radiation-induced crosslinking. The electron-beam processed acrylamide-gelatin polymer using glycerin as plasticizer must be first extensively characterized before to be used for general applications. (author)

  16. Penetration of electronic beams in ionizing media

    International Nuclear Information System (INIS)

    Martiarena, M.L.; Zanete, D.H.; Garibotti, C.R.

    1988-01-01

    It is studied the penetration of an electron beam in an ionizable medium by means of a generalized kinetic equation. This equation is related to elastic collisions, processes of creation and destruction of particles. By integrating numerically the transport equation, it can be evaluated the relative effects of all the processes involved in the evolution of the system. (A.C.A.S.) [pt

  17. Electron Beam Polarization Measurement Using Touschek Lifetime Technique

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Changchun; /Duke U., DFELL; Li, Jingyi; /Duke U., DFELL; Mikhailov, Stepan; /Duke U., DFELL; Popov, Victor; /Duke U., DFELL; Wu, Wenzhong; /Duke U., DFELL; Wu, Ying; /Duke U., DFELL; Chao, Alex; /SLAC; Xu, Hong-liang; /Hefei, NSRL; Zhang, Jian-feng; /Hefei, NSRL

    2012-08-24

    Electron beam loss due to intra-beam scattering, the Touschek effect, in a storage ring depends on the electron beam polarization. The polarization of an electron beam can be determined from the difference in the Touschek lifetime compared with an unpolarized beam. In this paper, we report on a systematic experimental procedure recently developed at Duke FEL laboratory to study the radiative polarization of a stored electron beam. Using this technique, we have successfully observed the radiative polarization build-up of an electron beam in the Duke storage ring, and determined the equilibrium degree of polarization and the time constant of the polarization build-up process.

  18. Enhanced epidermal dose caused by localized electron contamination from lead cutouts used in kilovoltage radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lye, J. E.; Butler, D. J.; Webb, D. V. [Australian Radiation and Protection and Nuclear Safety Agency, Yallambie, Melbourne 3085 (Australia)

    2010-08-15

    Purpose: To investigate and quantify electron contamination from the lead cutouts used in kilovoltage x-ray radiotherapy. Methods: The lead cutouts were modeled with the Monte Carlo EGSnrc user codes DOSXYZnrc and DOSRZnrc for x-ray beams ranging from 50 to 300 kV{sub p}. The results from the model were confirmed with Gafchromic film measurements. The model and measurements investigated the dose distribution with and without gladwrap shielding under the lead, and dose distributions with round, square, and serrated edge cutouts. Results: Large dose enhancement near the edges of the lead was observed due to electron contamination. At the epidermal/dermal border, there is double the dose at the edge of the lead compared to the central dose due to electron contamination for a 150 kV{sub p} beam and three times the dose for a 300 kV{sub p} beam. gladwrap shielding effectively removes the contaminant dose enhancement using ten and four layers for 300 and 150 kV{sub p} beams, respectively. Conclusions: The contaminant dose enhancement is undesirable as it could cause unnecessary erythema and hyperpigmentation at the border of the treated and untreated skin and lead to a poorer cosmetic outcome. The contamination is easily removed by gladwrap shielding placed under or around the lead cutout.

  19. Electron beam therapy with coil-generated magnetic fields

    International Nuclear Information System (INIS)

    Nardi, Eran; Barnea, Gideon; Ma, Chang-Ming

    2004-01-01

    This paper presents an initial study on the issues involved in the practical implementation of the use of transverse magnetic fields in electron beam therapy. By using such magnetic fields the dose delivered to the tumor region can increase significantly relative to that deposited to the healthy tissue. Initially we calculated the magnetic fields produced by the Helmholtz coil and modified Helmholtz coil configurations. These configurations, which can readily be used to generate high intensity magnetic fields, approximate the idealized magnetic fields studied in our previous publications. It was therefore of interest to perform a detailed study of the fields produced by these configurations. Electron beam dose distributions for 15 MeV electrons were calculated using the ACCEPTM code for a 3T transverse magnetic field produced by the modified Helmholtz configuration. The dose distribution was compared to those obtained with no magnetic field. The results were similar to those obtained in our previous work, where an idealized step function magnetic field was used and a 3T field was shown to be the optimal field strength. A simpler configuration was also studied in which a single external coil was used to generate the field. Electron dose distributions are also presented for a given geometry and given magnetic field strength using this configuration. The results indicate that this method is more difficult to apply to radiotherapy due to its lack of symmetry and its irregularity. For the various configurations dealt with here, a major problem is the need to shield the magnetic field in the beam propagation volume, a topic that must be studied in detail

  20. Parallel electron-beam-induced deposition using a multi-beam scanning electron microscope

    NARCIS (Netherlands)

    Post, P.C.; Mohammadi-Gheidari, A.; Hagen, C.W.; Kruit, P.

    2011-01-01

    Lithography techniques based on electron-beam-induced processes are inherently slow compared to light lithography techniques. The authors demonstrate here that the throughput can be enhanced by a factor of 196 by using a scanning electron microscope equipped with a multibeam electron source. Using

  1. Studies of space charge effects on operating electron beam ion trap at low electron beam energy

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xuelong; Fei, Zejie; Xiao, Jun; Lu, Di; Hutton, Roger [The Key Lab of Applied Ion Beam Physics, Ministry of Education (China); Shanghai EBIT Laboratory, Modern Physics Institute, Fudan University, Shanghai (China); Zou, Yaming, E-mail: zouym@fudan.edu.cn [The Key Lab of Applied Ion Beam Physics, Ministry of Education (China); Shanghai EBIT Laboratory, Modern Physics Institute, Fudan University, Shanghai (China)

    2013-08-21

    An electron beam ion trap (EBIT) is a powerful machine for disentangling studies of atomic processes in plasmas. To assist studies on edge plasma spectroscopic diagnostics, a very low energy EBIT, SH-PermEBIT, has been set up at the Shanghai EBIT lab. Large amounts of simulation works were done to study the factors which hinder the EBIT from operation at very low electron beam energies. Under the guide line of the simulation results, we finally managed to successfully reach 60 eV for the lower end of the electron beam energy with a beam transmission above 57%. In this presentation, simulation studies of the space charge effect, which is one of the most important causes of beam loss, was made based on Tricomp (Field precision)

  2. Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gallo, Salvatore; Veronese, Ivan [Universita degli Studi di Milano, Department of Physics, Milan (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Iacoviello, Giuseppina [Hospital ARNAS-Civico, Medical Physics Department, Palermo (Italy); Panzeca, Salvatore [Universita degli Studi di Palermo, Department of Physics and Chemistry, Palermo (Italy); Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania (Italy); Bartolotta, Antonio; Longo, Anna [Universita degli Studi di Palermo, Department of Physics and Chemistry, Palermo (Italy); Dondi, Daniele [Universita degli Studi di Pavia, Department of Chemistry, Pavia (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pavia (Italy); Gueli, Anna Maria [Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania (Italy); Universita degli Studi di Catania, Department of Physics and Astronomy, PH3DRA Laboratories, Catania (Italy); Loi, Gianfranco; Mones, Eleonora [Azienda Ospedaliero Universitaria Maggiore della Carita, Medical Physics Department, Novara (Italy); Marrale, Maurizio [Universita degli Studi di Palermo, Department of Physics and Chemistry, Palermo (Italy); Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania (Italy); Universita degli Studi di Palermo, Advanced Technologies Network Center (ATeN Center), Palermo (Italy)

    2017-11-15

    This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076 {sup registered}) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076 {sup registered} is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy. (orig.)

  3. European developments in radiotherapy with beams of large radiobiological effectiveness

    International Nuclear Information System (INIS)

    Amaldi, U.; Kraft, G.

    2007-01-01

    This paper reviews the European activities in the field of tumour therapy with beams which have a Radio Biological Effectiveness (RBE) larger than 1. Initially neutron beams have been used. Then charged pions promised better cure rates so that their use was pursued in the framework of the 'Piotron' project at the Paul Scherrer Institute (Switzerland). However both approaches did not meet the expectations and in the 80s the European Light Ion Medical Accelerator (EULIMA) project became the flagship of these attempts to improve the effects of the delivery of radiation doses of large RBE with respect to photons, electrons and even protons. The EULIMA ion accelerator was never built and it took more than ten years to see the approval, in Heidelberg and Pavia, of the construction of the Heidelberg Ion Therapy Centre (HIT) and National Centre for Oncological Hadrontherapy (CNAO) 'dual' centres for carbon ions and protons. In 2008 they will start treating patients. The developments that brought to these construction projects are described together with the special features of these two facilities. The third European dual centre is being built by Siemens Medical Systems in Marburg, Germany, while other facilities have been approved but not yet fully financed in Wiener Neustadt (Austria), Lyon (France) and Uppsala (Sweden). Finally the collaboration activities of the European Network the European Network for Light Ion Therapy (ENLIGHT) are presented together with the recent involvements of European industries in the construction of turn-key dual centres and the development of a new accelerator concept for hadrontherapy, the 'cyclinac'. (author)

  4. Electron beam driven disordering in small particles

    International Nuclear Information System (INIS)

    Vanfleet, R.R.; Mochel, J.

    1997-01-01

    Small metal particles in the range of a few nanometers in diameter are seen to progressively disorder when the 100 keV electron beam of a Scanning Transmission Electron Microscope (STEM) is held stationary on the particle. The diffraction pattern of the individual particle is seen to progress from an initial array of indexable diffraction spots to a mixture of diffraction spots and amorphous-like rings and finally to rings with no persistent diffraction spots. After the electron beam is removed, the particles will recrystallize after minutes or hours. Only particles below a critical size are seen to fully disorder. The authors have observed this in platinum, palladium, rhodium, and iridium and based on the model of disordering process believe it is a universal effect. It has also been observed with a platinum ruthenium alloy. They discuss the mechanism of this disordering and the structure of the resulting disordering particle for the case of platinum clusters

  5. Modification of fluoroelastomer by electron beam irradiation

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Montagna, Lea S.; Leitao Junior, Claudio B.; Pino, Eddy S.; Machado, Luci D.B.

    2005-01-01

    Fluoroelastomer is a polymer usually used as a sealing material due to some excellent properties, comparing to other elastomers, such as good chemical and thermal resistance. The fluoroelastomer used in this paper was a commercial product obtained from two monomers, vinylidene and hexafluoropropylene, containing also carbon black and inorganic fillers. Samples were irradiated with electron beam at doses from 10 to 250 kGy. The results obtained showed that electron beam radiation, in the studied conditions, promotes significant changes in the fluoroelastomer mechanical properties ending up in an increase of hardness, tensile strength and stiffness. The modifications on the mechanical properties can be related to a better adhesion between the fluoro elastomer and the fillers, induced by EB radiation. Micrographs obtained by Scanning Electron Microscopy for non-irradiated and irradiated samples confirmed this behavior. (author)

  6. Simplifying Electron Beam Channeling in Scanning Transmission Electron Microscopy (STEM).

    Science.gov (United States)

    Wu, Ryan J; Mittal, Anudha; Odlyzko, Michael L; Mkhoyan, K Andre

    2017-08-01

    Sub-angstrom scanning transmission electron microscopy (STEM) allows quantitative column-by-column analysis of crystalline specimens via annular dark-field images. The intensity of electrons scattered from a particular location in an atomic column depends on the intensity of the electron probe at that location. Electron beam channeling causes oscillations in the STEM probe intensity during specimen propagation, which leads to differences in the beam intensity incident at different depths. Understanding the parameters that control this complex behavior is critical for interpreting experimental STEM results. In this work, theoretical analysis of the STEM probe intensity reveals that intensity oscillations during specimen propagation are regulated by changes in the beam's angular distribution. Three distinct regimes of channeling behavior are observed: the high-atomic-number (Z) regime, in which atomic scattering leads to significant angular redistribution of the beam; the low-Z regime, in which the probe's initial angular distribution controls intensity oscillations; and the intermediate-Z regime, in which the behavior is mixed. These contrasting regimes are shown to exist for a wide range of probe parameters. These results provide a new understanding of the occurrence and consequences of channeling phenomena and conditions under which their influence is strengthened or weakened by characteristics of the electron probe and sample.

  7. Electron Accelerators for Radioactive Ion Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lia Merminga

    2007-10-10

    The summary of this paper is that to optimize the design of an electron drive, one must: (a) specify carefully the user requirements--beam energy, beam power, duty factor, and longitudinal and transverse emittance; (b) evaluate different machine options including capital cost, 10-year operating cost and delivery time. The author is convinced elegant solutions are available with existing technology. There are several design options and technology choices. Decisions will depend on system optimization, in-house infrastructure and expertise (e.g. cryogenics, SRF, lasers), synergy with other programs.

  8. Generation and study of relativistic electron beam

    International Nuclear Information System (INIS)

    Iyyengar, S.K.; Ron, P.H.; Mittal, K.C.; Goel, A.K.; Ramaswamy, V.; Rohatgi, V.K.

    1977-01-01

    Pulsed Electron Beam (REB) technology has progressed rapidly in recent years because of applications in various fields like radiation sources, high power laser development, plasma heating and fusion research. The REB development programme at the Plasma Physics Section of Bhabha Atomic Research Centre, Bombay, has been described. The design features of the 375 KV, 3500 A, 75 Joule REB generator are discussed. The diagnostic equipment developed for the studies is described. The present experimental studies and some preliminary results on beam characterisation are presented. (author)

  9. Dose computation for therapeutic electron beams

    Science.gov (United States)

    Glegg, Martin Mackenzie

    The accuracy of electron dose calculations performed by two commercially available treatment planning computers, Varian Cadplan and Helax TMS, has been assessed. Measured values of absorbed dose delivered by a Varian 2100C linear accelerator, under a wide variety of irradiation conditions, were compared with doses calculated by the treatment planning computers. Much of the motivation for this work was provided by a requirement to verify the accuracy of calculated electron dose distributions in situations encountered clinically at Glasgow's Beatson Oncology Centre. Calculated dose distributions are required in a significant minority of electron treatments, usually in cases involving treatment to the head and neck. Here, therapeutic electron beams are subject to factors which may cause non-uniformity in the distribution of dose, and which may complicate the calculation of dose. The beam shape is often irregular, the beam may enter the patient at an oblique angle or at an extended source to skin distance (SSD), tissue inhomogeneities can alter the dose distribution, and tissue equivalent material (such as wax) may be added to reduce dose to critical organs. Technological advances have allowed the current generation of treatment planning computers to implement dose calculation algorithms with the ability to model electron beams in these complex situations. These calculations have, however, yet to be verified by measurement. This work has assessed the accuracy of calculations in a number of specific instances. Chapter two contains a comparison of measured and calculated planar electron isodose distributions. Three situations were considered: oblique incidence, incidence on an irregular surface (such as that which would be arise from the use of wax to reduce dose to spinal cord), and incidence on a phantom containing a small air cavity. Calculations were compared with measurements made by thermoluminescent dosimetry (TLD) in a WTe electron solid water phantom. Chapter

  10. Transverse electron beam diagnostics at REGAE

    International Nuclear Information System (INIS)

    Bayesteh, Shima

    2014-12-01

    The use of high-intensity electron and X-ray pulsed sources allows for the direct observation of atomic motions as they occur. While the production of such high coherent, brilliant, short X-ray pulses requires large-scale and costly accelerator facilities, it is feasible to employ a high-intensity source of electrons by exploiting a more compact design. The Relativistic Electron Gun for Atomic Exploration (REGAE) facility is a small linear accelerator at DESY, Hamburg, equipped with a photocathode radio frequency (RF) gun that produces relativistic ultra-short (<100 fs), low charge (<1 pC) electron bunches of high coherence. By means of time-resolved diffraction experiments, such an electron source can probe ultrafast laser-induced atomic structural changes that occur with a temporal resolution of ∝100 fs. A comprehensive characterization of the electron beam, for every pulse, is of fundamental importance to study the atomic motions with the desired resolution and quality. This thesis reports on the transversal diagnostics of the electron beam with an emphasis on a scintillator-based beam profile monitor. The diagnostics is capable of evaluating the beam parameters such as charge, energy, energy spread and transverse profile, at very low charges and on a shot-to-shot basis. A full characterization of the scintillator's emission, the optical setup and the detector (camera) of the profile monitor is presented, from which an absolute charge calibration of the system is derived. The profile monitor is specially developed to accommodate more applications, such as dark current suppression, overlapping the electron probe and the laser pump within 1 ns accuracy, as well as charge and transverse emittance measurements. For the determination of the transverse emittance two techniques were applied. The first one introduces a new method that exploits a diffraction pattern to measure the emittance, while the second one is based on a version of the Pepper-pot technique. A

  11. External beam radiotherapy facilities in Ukraine. Trends and challenges

    International Nuclear Information System (INIS)

    Starenkiy, V.P.; Petrichenko, O.O.; Averyanova, L.O.

    2017-01-01

    The most important aspects of technological support of the radiation therapy of Ukraine are considered in accordance with the requirements of the IAEA. The reasons that influence the availability of radiotherapy for cancer patients in Ukraine are analyzed taking into account the experience of Grigoriev Institute for Medical Radiology of the National Academy of Medical Sciences of Ukraine.

  12. Production of slow-positron beams with an electron linac

    International Nuclear Information System (INIS)

    Howell, R.H.; Alvarez, R.A.; Stanek, M.

    1982-01-01

    Intense, pulsed beams of low-energy positrons have been produced by a high-energy beam from an electron linac. The production efficiency for low-energy positrons has been determined for electrons with 60 to 120 MeV energy, low-energy positron beams from a linac can be of much higher intensity than those beams currently derived from radioactive sources

  13. An assessment of effective dose to staff in external beam radiotherapy

    International Nuclear Information System (INIS)

    Rawlings, D.J.; Nicholson, L.

    1997-01-01

    Radiation safety in external beam radiotherapy is governed by national legislation. Annual doses recorded by radiographers and others associated with external beam radiotherapy are typically much lower than the relevant dose limit. However, it is possible that larger doses might be received as a result of an accidental irradiation. In the event of a significant exposure resulting in a dose at or near a relevant dose limit, an accurate conversion has to be made from the dose meter reading to the limiting quantity. A method was devised to demonstrate ratios of effective dose to personal dose equivalent which might be anticipated in the even of an individual other than the patient being irradiated within a radiotherapy treatment room consisting of a linear accelerator. The variation of ratios obtained under different conditions is discussed. (author)

  14. Electron Beam Welding of Gear Wheels by Splitted Beam

    Directory of Open Access Journals (Sweden)

    Dřímal Daniel

    2014-06-01

    Full Text Available This contribution deals with the issue of electron beam welding of high-accurate gear wheels composed of a spur gearing and fluted shaft joined with a face weld for automotive industry. Both parts made of the high-strength low-alloy steel are welded in the condition after final machining and heat treatment, performed by case hardening, whereas it is required that the run-out in the critical point of weldment after welding, i. e. after the final operation, would be 0.04 mm max..

  15. Study on local vacuum electron beam welding of flange rim

    CERN Document Server

    He Cheng Dan; Ying Lei; Xu Qi Jin

    2002-01-01

    Local vacuum electron beam welding and its application prospect in military and civil industry are introduced. A home made local vacuum electron beam welding is completed. Its main technical parameters and key techniques are also presented

  16. Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables

    DEFF Research Database (Denmark)

    Nielsen, Morten; Hansen, C. R.; Brink, C.

    2016-01-01

    Flattening filter free (FFF) high dose rate beam technique was introduced for brain stereotactic radiosurgery (SRS) and lung Stereotactic Body Radiotherapy (SBRT). Furthermore, a HexaPOD treatment table was introduced for the brain SRS to enable correction of rotational setup errors. 19 filter fl.......3 degrees (SD1.2 degrees) to 0.06 degrees (SD 0.3 degrees)....

  17. Proton beam radiotherapy of choroidal melanoma: The Liverpool-Clatterbridge experience

    International Nuclear Information System (INIS)

    Damato, Bertil; Kacperek, Andrzej; Chopra, Mona; Campbell, Ian R.; Errington, R. Douglas

    2005-01-01

    Purpose To report on outcomes after proton beam radiotherapy of choroidal melanoma using a 62-MeV cyclotron in patients considered unsuitable for other forms of conservative therapy. Methods and Materials A total of 349 patients with choroidal melanoma referred to the Liverpool Ocular Oncology Centre underwent proton beam radiotherapy at Clatterbridge Centre for Oncology (CCO) between January 1993 and December 2003. Four daily fractions of proton beam radiotherapy were delivered, with a total dose of 53.1 proton Gy, and with lateral and distal safety margins of 2.5 mm. Outcomes measured were local tumor recurrence; ocular conservation; vision; and metastatic death according to age, gender, eye, visual acuity, location of anterior and posterior tumor margins, quadrant, longest basal tumor dimension, tumor height, extraocular extension, and retinal invasion. Results The 5-year actuarial rates were 3.5% for local tumor recurrence, 9.4% for enucleation, 79.1% for conservation of vision of counting fingers or better, 61.1% for conservation of vision of 20/200 or better, 44.8% for conservation of vision of 20/40 or better, and 10.0% for death from metastasis. Conclusion Proton beam radiotherapy with a 62 MeV cyclotron achieves high rates of local tumor control and ocular conservation, with visual outcome depending on tumor size and location

  18. A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakar, Ramachandran; Cramb, Jim; Kron, Tomas [Physical Sciences, Peter MacCallum Cancer Centre, Locked Bag 1, A' Beckett Street, Victoria 8006 (Australia)

    2011-12-15

    Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry

  19. Large area electron beam diode development

    International Nuclear Information System (INIS)

    Helava, H.; Gilman, C.M.; Stringfield, R.M.; Young, T.

    1983-01-01

    A large area annular electron beam diode has been tested at Physics International Co. on the multi-terawatt PITHON generator. A twelve element post hole convolute converted the coaxial MITL into a triaxial arrangement of anode current return structures both inside and outside the cathode structure. The presence of both inner and outer current return paths provide magnetic pressure balance for the beam, as determined by diode current measurements. X-ray pinhole photographs indicated uniform emission with intensity maxima between the post positions. Current losses in the post hole region were negligible, as evidenced by the absence of damage to the aluminum hardware. Radial electron flow near the cathode ring however did damage the inner anode cylinder between the post positions. Cutting away these regions prevented further damage of the transmission lines

  20. Profiles of an initially perturbed electron beam

    International Nuclear Information System (INIS)

    Abdelsalam, F.W.

    1991-01-01

    This paper discusses the solutions for the profiles of an electron beam which is launched into a constant magnetic field with an initial boundary slope and injected with a radius which is greater or less than the cathode radius. It has been found that the outermost electron traces sine waves and executes limited excursions when the initial boundary slope corresponds to angles up to 1 degree, no matter whether the initial radius is 0.90 or 1.10 times the radius of the cathode. For initial inclination angles close to 2 degrees, the beam boundary does not preserve a sinusoidal shape, this statement holds true for focusing magnetic flux densities varying from 200x10 -4 to 700x10 -4 weber per square meter

  1. NOx reduction by compact electron beam processing

    International Nuclear Information System (INIS)

    Penetrante, B.M.; Hsiao, M.C.; Merritt, B.T.; Wallman, P.H.; Vogtlin, G.E.

    1995-01-01

    Among the new methods being investigated for the post-combustion removal of nitrogen oxides (NO x ) are based on non-thermal plasmas. These plasmas can be produced by electrical discharge methods or electron beam irradiation. The application of electron beam irradiation for NO x removal in power plant flue gases has been investigated since the early 1970's in both laboratory- and pilot-scale experiments. Electrical discharge methods are relatively new entrants in the field of flue gas cleanup. Pulsed corona and dielectric-barrier discharge techniques are two of the more commonly used electrical discharge methods for producing nonthermal plasmas at atmospheric pressure. There are basically two types of reactions responsible for the depletion of NO by non-thermal plasmas: oxidation and reduction

  2. Quantitative Analysis of Electron Beam Damage in Organic Thin Films

    OpenAIRE

    Leijten, Zino J. W. A.; Keizer, Arthur D. A.; de With, Gijsbertus; Friedrich, Heiner

    2017-01-01

    In transmission electron microscopy (TEM) the interaction of an electron beam with polymers such as P3HT:PCBM photovoltaic nanocomposites results in electron beam damage, which is the most important factor limiting acquisition of structural or chemical data at high spatial resolution. Beam effects can vary depending on parameters such as electron dose rate, temperature during imaging, and the presence of water and oxygen in the sample. Furthermore, beam damage will occur at different length s...

  3. Irradiation of Gemstones using Electron Beam

    International Nuclear Information System (INIS)

    Sarada Idris; Mohd Suhaimi Jusoh; Siti Aiasah Hashim

    2011-01-01

    Gemstone irradiation treatment using radiation is one of the studies conducted in the ALURTRON. The purpose of radiation is to study the effects of radiation on the gems. Through studies conducted on freshwater pearls and stones such as Topaz, Kunzite, TOURMALINE, Aquamarine, Quartz and so on, electron beam irradiation method can highlight the jewel colors but also to reduce the effects of haze on gemstones. The dose of radiation used is 25 kGy to 200 kGy. (author)

  4. Polarization in electron and proton beams

    International Nuclear Information System (INIS)

    Buon, J.

    1986-03-01

    One first introduces the concept of polarization for spin 1/2 particle beams and discusses properties of spin kinetics in a stationary magnetic field. Then the acceleration of polarized protons in synchrotrons is studied with emphasis on depolarization when resonances are crossed and on the cures for reducing it. Finally, transverse polarization of electrons in storage rings is discussed as an equilibrium between polarizing and depolarizing effects of synchrotron radiation. Means for obtaining longitudinal polarization are also treated

  5. Manipulation and electron-oscillation-measurement of laser accelerated electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kotaki, H; Hayashi, Y; Kawase, K; Mori, M; Kando, M; Homma, T; Koga, J K; Daido, H; Bulanov, S V, E-mail: kotaki.hideyuki@jaea.go.jp [Advanced Photon Research Center, Japan Atomic Energy Agency, 8-1-7, Umemidai, Kizugawa, Kyoto (Japan)

    2011-01-15

    Monoenergetic electron beams have been generated in the self-injection scheme of laser acceleration. In applications of these laser accelerated electron beams, stable and controllable electron beams are necessary. A stable electron beam is generated in the self-injection scheme by using a nitrogen gas jet target. We found the profile of the electron beam was manipulated by rotating the laser polarization. The electron beam is in the first bucket of the wake wave. In the energy space, transverse oscillation is observed when the laser pulse has S-polarization. The direction of the electron beam is controlled by the gas jet position.

  6. Exhaust gas treatment by electron beam irradiation

    International Nuclear Information System (INIS)

    Shibamura, Yokichi; Suda, Shoichi; Kobayashi, Toshiki

    1991-01-01

    Among global environmental problems, atmospheric pollution has been discussed since relatively old days, and various countermeasures have been taken, but recently in connection with acid rain, the efficient and economical treatment technology is demanded. As the denitration and desulfurization technology for the exhaust gas from the combustion of fossil fuel, the incineration of city trash and internal combustion engines, three is the treatment method by electron beam irradiation. By irradiating electron beam to exhaust gas, nitrogen oxides and sulfur oxides are oxidized to nitric acid and sulfuric acid, and by promoting the neutralization of these acids with injected alkali, harmless salts are recovered. This method has the merit that nitrogen oxides and surfur oxides can be removed efficiently with a single system. In this report, as for the exhaust gas treatment by electron beam irradiation, its principle, features, and the present status of research and development are described, and in particular, the research on the recent exhaust gas treatment in city trash incineration is introduced. This treatment method is a dry process, accordingly, waste water disposal is unnecessary. The reaction products are utilized as fertilizer, and waste is not produced. (K.I.)

  7. Modulated electron radiotherapy treatment planning using a photon multileaf collimator for post-mastectomized chest walls

    International Nuclear Information System (INIS)

    Salguero, Francisco Javier; Palma, Bianey; Arrans, Rafael; Rosello, Joan; Leal, Antonio

    2009-01-01

    Background and purpose: To evaluate the feasibility of using a photon MLC (xMLC) for modulated electron radiotherapy treatment (MERT) as an alternative to conventional post-mastectomy chest wall (CW) irradiation. A Monte Carlo (MC) based planning system was developed to overcome the inaccuracy of the 'pencil beam' algorithm. MC techniques are known to accurately calculate the dose distributions of electron beams, allowing the explicit simulation of electron interactions within the MLC. Materials and methods: Four real clinical CW cases were planned using MERT which were compared with the conventional electron treatments based on blocks and by a straightforward approach using the MLC, and not the blocks (as an intermediate step to MERT) to shape the same segments with SSD between 60 and 70 cm depending on PTV size. MC calculations were verified with an array of ionization chambers and radiochromic films in a solid water phantom. Results: Tests based on gamma analysis between MC dose distributions and radiochromic film measurements showed an excellent agreement. Differences in the absolute dose measured with a plane-parallel chamber at a reference point were below 3% for all cases. MERT solution showed a better PTV coverage and a significant reduction of the doses to the organs at risk (OARs). Conclusion: MERT can effectively improve the current electron treatments by obtaining a better PTV coverage and sparing healthy tissues. More directly, block-shaped treatments could be replaced by MLC-shaped non-modulated segments providing similar results.

  8. Effects of electron beam irradiation on tin dioxide gas sensors

    Indian Academy of Sciences (India)

    In this paper, the effects of electron beam irradiation on the gas sensing performance of tin dioxide thin films toward H2 are studied. The tin dioxide thin films were prepared by ultrasonic spray pyrolysis. The results show that the sensitivity increased after electron beam irradiation. The electron beam irradiation effects on tin ...

  9. External beam radiotherapy combined with intraluminal brachytherapy in esophageal carcinoma

    International Nuclear Information System (INIS)

    Muijs, Christina T.; Beukema, Jannet C.; Mul, Veronique E.; Plukker, John Th.; Sijtsema, Nanna M.; Langendijk, Johannes A.

    2012-01-01

    Purpose: To assess the effectiveness of definitive radiation therapy in patients with potentially curable esophageal cancer and to evaluate the side-effects of this treatment. Methods and materials: Sixty-two patients with esophageal cancer, who were treated with definitive, curatively intended radiotherapy consisting of external radiotherapy (60 Gy in 30 fractions), preceded and followed by LDR or HDR intraluminal brachy (12 Gy in 2 fractions) were retrospectively analyzed. Results: Recurrences were reported in 38 patients (61%), of which 25 (64%) failed locally first. The overall survival rates at 1, 2 and 5 years were 57%, 34% and 11%, respectively. The median overall survival was 15 months. No prognostic factors could be identified. Most frequently reported treatment related toxicities were esophagitis, ulcerations, (11%) and strictures (16%). In 10 patients (16%) severe toxicities, were reported including grade III ulceration (2 cases), stricture (1 case), radiation pneumonitis (1 case), perforation (1 case), esophageal-pleural-tracheal fistula (1 case), and acute esophageal bleeding (4 cases). A history of gastrectomy was significantly associated with the development of severe toxicity. Conclusion: Curatively intended radiotherapy alone can be offered to esophageal cancer patients, even when surgery and/or chemotherapy are not feasible. However, we observed severe toxicity in a substantial part of the patients. Given the relatively high rate of severe complications and the uncertainties regarding dose escalation, the addition of brachytherapy, with consequently high surface doses, should be limited to well-selected patients.

  10. Ion accumulation and space charge neutralization in intensive electron beams for ion sources and electron cooling

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1996-01-01

    The Electron Beam Ion Sources (EBIS), Electron Beam Ion Traps (EBIT) and electron beams for electron cooling application have the beam parameters in the same ranges of magnitudes. EBIS and EBIT produce and accumulate ions in the beam due to electron impact ionization. The cooling electron beam accumulates positive ions from the residual gas in the accelerator chamber during the cooling cycle. The space charge neutralization of cooling beam is also used to reduce the electron energy spread and enhance the cooling ability. The advanced results of experimental investigations and theoretical models of the EBIS electron beams are applied to analyze the problem of beam neutralization in the electron cooling techniques. The report presents the analysis of the most important processes connected with ion production, accumulation and losses in the intensive electron beams of ion sources and electron cooling systems for proton and ion colliders. The inelastic and elastic collision processes of charged particles in the electron beams are considered. The inelastic processes such as ionization, charge exchange and recombination change the charge states of ions and neutral atoms in the beam. The elastic Coulomb collisions change the energy of particles and cause the energy redistribution among components in the electron-ion beams. The characteristic times and specific features of ionization, beam neutralization, ion heating and loss in the ion sources and electron cooling beams are determined. The dependence of negative potential in the beam cross section on neutralization factor is studied. 17 refs., 5 figs., 1 tab

  11. First test of BNL electron beam ion source with high current density electron beam

    International Nuclear Information System (INIS)

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.; Shornikov, Andrey; Mertzig, Robert; Wenander, Fredrik; Scrivens, Richard

    2015-01-01

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm 2 and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, the EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given

  12. Use of beam deflection to control an electron beam wire deposition process

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hofmeister, William H. (Inventor); Hafley, Robert A. (Inventor)

    2013-01-01

    A method for controlling an electron beam process wherein a wire is melted and deposited on a substrate as a molten pool comprises generating the electron beam with a complex raster pattern, and directing the beam onto an outer surface of the wire to thereby control a location of the wire with respect to the molten pool. Directing the beam selectively heats the outer surface of the wire and maintains the position of the wire with respect to the molten pool. An apparatus for controlling an electron beam process includes a beam gun adapted for generating the electron beam, and a controller adapted for providing the electron beam with a complex raster pattern and for directing the electron beam onto an outer surface of the wire to control a location of the wire with respect to the molten pool.

  13. Applications of electron lenses: scraping of high-power beams, beam-beam compensation, and nonlinear optics

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio

    2014-09-11

    Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam. Electron lenses were used in the Fermilab Tevatron collider for bunch-by-bunch compensation of long-range beam-beam tune shifts, for removal of uncaptured particles in the abort gap, for preliminary experiments on head-on beam-beam compensation, and for the demonstration of halo scraping with hollow electron beams. Electron lenses for beam-beam compensation are being commissioned in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). Hollow electron beam collimation and halo control were studied as an option to complement the collimation system for the upgrades of the Large Hadron Collider (LHC) at CERN; a conceptual design was recently completed. Because of their electric charge and the absence of materials close to the proton beam, electron lenses may also provide an alternative to wires for long-range beam-beam compensation in LHC luminosity upgrade scenarios with small crossing angles. At Fermilab, we are planning to install an electron lens in the Integrable Optics Test Accelerator (IOTA, a 40-m ring for 150-MeV electrons) as one of the proof-of-principle implementations of nonlinear integrable optics to achieve large tune spreads and more stable beams without loss of dynamic aperture.

  14. Efficient electron beam deposition for repetitively pulsed krypton fluoride lasers

    International Nuclear Information System (INIS)

    Hegeler, F.; Myers, M.C.; Friedman, M.; Sethian, J.D.; Swanekamp, S.B.; Rose, D.V.; Welch, D.R.

    2002-01-01

    We have demonstrated that we can significantly increase the electron beam transmission efficiency through a pressure foil structure (hibachi) by segmenting the beam into strips to miss the hibachi support ribs. In order to increase the electron beam transmission, the cathode strips are adjusted to compensate for beam rotation and pinching. The beam propagation through the hibachi has been both measured and simulated with 1-D and 3-D codes

  15. Combined phenomena of beam-beam and beam-electron cloud interactionsin circular e^{+}e^{-} colliders

    Directory of Open Access Journals (Sweden)

    Kazuhito Ohmi

    2002-10-01

    Full Text Available An electron cloud causes various effects in high intensity positron storage rings. The positron beam and the electron cloud can be considered a typical two-stream system with a certain plasma frequency. Beam-beam interaction is another important effect for high luminosity circular colliders. Colliding two beams can be considered as a two-stream system with another plasma frequency. We study the combined phenomena of the beam-electron cloud and beam-beam interactions from a viewpoint of two complex two-stream effects with two plasma frequencies.

  16. An electromagnetically focused electron beam line source

    International Nuclear Information System (INIS)

    Iqbal, Munawar; Masood, Khalid; Rafiq, Mohammad; Chaudhary, Maqbool A.; Aleem, Fazal-e-

    2003-01-01

    A directly heated thermionic electron beam source was constructed. A tungsten wire of length 140 mm with diameter 0.9 mm was used as a cathode. An emission current of 5000 mA was achieved at an input heating power of 600 W. Cathode to anode distance of 6 mm with acceleration voltage of 10 kV was used. A uniform external magnetic field of 50 G was employed to obtain a well-focused electron beam at a deflection of 180 deg., with cathode to work site distance of 130 mm. Dimensions of the beam (1.25x120 mm) recorded at the work site were found to be in good agreement with the designed length of cathode. The deformation of the cathode was overcome by introducing a spring action mechanism, which gives uniform emission current density throughout the emission surface. We have achieved the saturation limit of the designed source resulting in smooth and swift operation of the gun for many hours (10-15 h continuously). The design of gun is so simple that it can accommodate longer cathodes for obtaining higher emission values. This gun has made it possible to coat large substrate surfaces at much faster evaporation rate at lower cost. It can also be useful in large-scale vacuum metallurgy plants for melting, welding and heat treatment

  17. Electron beam directed energy device and methods of using same

    Science.gov (United States)

    Retsky, Michael W.

    2007-10-16

    A method and apparatus is disclosed for an electron beam directed energy device. The device consists of an electron gun with one or more electron beams. The device includes one or more accelerating plates with holes aligned for beam passage. The plates may be flat or preferably shaped to direct each electron beam to exit the electron gun at a predetermined orientation. In one preferred application, the device is located in outer space with individual beams that are directed to focus at a distant target to be used to impact and destroy missiles. The aimings of the separate beams are designed to overcome Coulomb repulsion. A method is also presented for directing the beams to a target considering the variable terrestrial magnetic field. In another preferred application, the electron beam is directed into the ground to produce a subsurface x-ray source to locate and/or destroy buried or otherwise hidden objects including explosive devices.

  18. Ultra-High Density Electron Beams for Beam Radiation and Beam Plasma Interaction

    CERN Document Server

    Anderson, Scott; Frigola, Pedro; Gibson, David J; Hartemann, Fred V; Jacob, Jeremy S; Lim, Jae; Musumeci, Pietro; Rosenzweig, James E; Travish, Gil; Tremaine, Aaron M

    2005-01-01

    Current and future applications of high brightness electron beams, which include advanced accelerators such as the plasma wake-field accelerator (PWFA) and beam-radiation interactions such as inverse-Compton scattering (ICS), require both transverse and longitudinal beam sizes on the order of tens of microns. Ultra-high density beams may be produced at moderate energy (50 MeV) by compression and subsequent strong focusing of low emittance, photoinjector sources. We describe the implementation of this method used at LLNL's PLEIADES ICS x-ray source in which the photoinjector-generated beam has been compressed to 300 fsec duration using the velocity bunching technique and focused to 20 μm rms size using an extremely high gradient, permanent magnet quadrupole (PMQ) focusing system.

  19. Electron beam application in gas waste treatment in China

    International Nuclear Information System (INIS)

    Wu Haifeng

    2003-01-01

    In the most recent decade, electron beam waste treatment technology attracted serious attention from environment policymaker and industrial leaders in power industry in China. Starting in middle of 1980's, Chinese research institute began experiment of electron beam treatment on flue gas. By the end of 2000, two 10,000 cubic meters per hour small scale electron beam gas purifying station were established in Sichuang province and Beijing. Several electron beam gas purifying demonstration projects are under construction. With robust economy and strong energy demand, needless to say, in near future, electron beam gas purifying technology will have a bright prospect in China. (author)

  20. Environmental applications of electron-beam technology

    International Nuclear Information System (INIS)

    Pikaev, A.K.

    2001-01-01

    The main directions of modern environmental applications of electron-beam technology are the following: 1) treatment of polluted natural and drinking water, municipal and industrial wastewater, other liquid wastes; 2) purification of gases; 3) treatment of sewage sludges; 4) treatment of solid wastes (medical wastes, contaminated soil and so on). In some cases, the results of respective researches and developments found a large-scale application. For example, recently several industrial plants for electron-beam purification of flue gases of thermal power plants from SO2 and NOx were created in China, Poland and Japan. In the report, a brief summary of the most important results obtained in the mentioned directions will be presented. A special attention will be paid to the data in the first direction. In particular, the recent results on radiation treatment of some liquid systems obtained in the laboratory under author's leadership will be considered. One of them is water polluted with petroleum products (motor oil, diesel fuel, residual fuel oil). The pollutants were present in water in dissolved form and as a separate phase. It was found that irradiation (dose 25-40 kGy) decomposes and removes the pollutants as a precipitate. The second system is natural oil gas consisting of gaseous and low-boiling hydrocarbons, water and so on. Laboratory- and pilot-scale (with electron accelerator of 0.7 MeV and 30 kW) studies have shown that electron-beam treatment (in a recycling regime with continuous sampling the liquid phase) of this gas leads to the formation of a mixture of liquid branched hydrocarbons, alcohols, ethers and so on, i.e., there is a radiation-induced liquefaction of the natural oil gas. The mechanism of radiolytic conversions occurring in the mentioned systems will be discussed

  1. Measurement and modeling of the dose distribution in homogenous medium for a proton beam devoted to radiotherapy

    International Nuclear Information System (INIS)

    Oozeer, R.

    1996-12-01

    A theoretical and experimental study of the dose distribution in the proton beams of the proton therapy center at Orsay has been investigated. The theoretical study highlighted the prominent interactions of protons used for radiotherapy with the biological media, are the energy loss by inelastic collisions with electrons, and the multiple coulomb diffusions with nuclei. Experimental measurements have been realised with a small size diode in homogenous and heterogenous medium. The measurements in a water phantom lead to the finalizing of a lateral penumbra model for the intra skull beam. The measurements in heterogenous medium highlighted the importance of the fine structure of heterogeneities on the yield in depth curve shape. Concerning the simple fine structure heterogeneities, we defined the notions of equivalence to water for the heterogeneities, specific to protons, concerning the yields in depth and the diffusion. Moreover, a calculation of dose distribution, for a mono energy beam in a phantom of simple geometry, using the mini beam technique and the Highland formalism was implemented. This approach is compatible with a definition of heterogeneities as macroscopic structure. Concerning the heterogeneities of fine structure (equally complex), an analysis of the degradation of yield in depth curves was lead, indicating that it was possible to to take them into account from the scanner images. A such approach implies calculation models using directly the electronic density relative to water of each of voxel intercepted by the radiation. (N.C.)

  2. Effect of age-dependent bone electron density on the calculated dose distribution from kilovoltage and megavoltage photon and electron radiotherapy in paediatric MRI-only treatment planning.

    Science.gov (United States)

    Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Saeedi-Moghadam, M; Jalli, R; Sina, S

    2018-01-01

    MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone density variations in children on radiation attenuation and dose calculation for MRI-only TP. Bone contents of dose and beam profile of 150 kVp and 6 MV photon and 6 MeV electron beams were then calculated using Xcom, MCNPX (Monte Carlo N-particle version X) and ORLN phantoms. Using 150 kVp X-rays, the difference in attenuation coefficient was almost 5% between an 11-year-old child and a newborn, and ~8% between an adult and a newborn. With megavoltage radiation, the differences were smaller but still important. For an 18 MV photon beam, the difference of radiation attenuation between an 11-year-old child and a newborn was 4% and ~7.4% between an adult and a newborn. For 6 MeV electrons, dose differences were observed up to the 2 cm depth. The percentage depth dose difference between 1 and 10-year-olds was 18.5%, and between 10 and 15-year-olds was 24%. The results suggest that for MRI-only TP of photon- or electron-beam radiotherapy, the bone densities of each age group should be defined separately for accurate dose calculation. Advances in knowledge: This study highlights the need for more age-specific determination of bone electron density for accurate dose calculations in paediatric MRI-only radiotherapy TP.

  3. Comparison study of in vivo dose response to laser-driven versus conventional electron beam.

    Science.gov (United States)

    Oppelt, Melanie; Baumann, Michael; Bergmann, Ralf; Beyreuther, Elke; Brüchner, Kerstin; Hartmann, Josefin; Karsch, Leonhard; Krause, Mechthild; Laschinsky, Lydia; Leßmann, Elisabeth; Nicolai, Maria; Reuter, Maria; Richter, Christian; Sävert, Alexander; Schnell, Michael; Schürer, Michael; Woithe, Julia; Kaluza, Malte; Pawelke, Jörg

    2015-05-01

    The long-term goal to integrate laser-based particle accelerators into radiotherapy clinics not only requires technological development of high-intensity lasers and new techniques for beam detection and dose delivery, but also characterization of the biological consequences of this new particle beam quality, i.e. ultra-short, ultra-intense pulses. In the present work, we describe successful in vivo experiments with laser-driven electron pulses by utilization of a small tumour model on the mouse ear for the human squamous cell carcinoma model FaDu. The already established in vitro irradiation technology at the laser system JETI was further enhanced for 3D tumour irradiation in vivo in terms of beam transport, beam monitoring, dose delivery and dosimetry in order to precisely apply a prescribed dose to each tumour in full-scale radiobiological experiments. Tumour growth delay was determined after irradiation with doses of 3 and 6 Gy by laser-accelerated electrons. Reference irradiation was performed with continuous electron beams at a clinical linear accelerator in order to both validate the dedicated dosimetry employed for laser-accelerated JETI electrons and above all review the biological results. No significant difference in radiation-induced tumour growth delay was revealed for the two investigated electron beams. These data provide evidence that the ultra-high dose rate generated by laser acceleration does not impact the biological effectiveness of the particles.

  4. Accelerators in industrial electron beam processing

    International Nuclear Information System (INIS)

    Becker, R.C.

    1984-01-01

    High power electron beam accelerators are being used for a variety of industrial processes. Such machines can process a wide range of products at very high thruput rates and at very low unit processing costs. These industrial accelerators are now capable of producing up to 200 kW of electron beam power at 4.0 MV and 100 kW at 5.0 MV. At this writing, even larger units are contemplated. The reliability of these high power devices also makes it feasible to consider bremsstrahlung (x-ray) processing as well. In addition to the advance of accelerator technology, microprocessor control systems now provide the capability to coordinate all the operations of the irradiation facility, including the accelerator, the material handling system, the personnel safety system and various auxiliary services. Facility designs can be adapted to many different industrial processes, including use of the dual purpose electron/x-ray accelerator, to ensure satisfactory product treatment with good dose uniformity, high energy efficiency and operational safety and simplicity. In addition, equipment manufacturers like RDI are looking beyond their conventional DC accelerator technology; looking at high power 10-12 MeV linear accelerators with power levels up to 25 kW or more. These high power linear accelerators could be the ideal processing tool for many sterilization and food irradiation applications. (author)

  5. The CMS Beam Halo Monitor Electronics

    CERN Document Server

    AUTHOR|(CDS)2080684; Fabbri, F.; Grassi, T.; Hughes, E.; Mans, J.; Montanari, A.; Orfanelli, S.; Rusack, R.; Torromeo, G.; Stickland, D.P.; Stifter, K.

    2016-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providi...

  6. Polystyrene as a zwitter resist in electron beam lithography based ...

    Indian Academy of Sciences (India)

    The resist action of polystyrene (w, 2,600,000) towards electroless deposition of gold on Si(100) surface following cross-linking by exposing to a 10 kV electron beam, has been investigated employing a scanning electron microscope equipped with electron beam lithography tool. With a low dose of electrons (21 C/cm2), ...

  7. Limits to Electron Beam Emittance from Stochastic Coulomb Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Coleman-Smith, Christopher; Padmore, Howard A.; Wan, Weishi

    2008-08-22

    Dense electron beams can now be generated on an ultrafast timescale using laser driven photo-cathodes and these are used for a range of applications from ultrafast electron defraction to free electron lasers. Here we determine a lower bound to the emittance of an electron beam limited by fundamental stochastic Coulomb interactions.

  8. Review of common accidents in external beam radiotherapy

    International Nuclear Information System (INIS)

    Ombogo, C.M

    2015-02-01

    This work covers patients protection in Radiotherapy which is a multi step procedure that is complex. Any error in any step has an effect on the patient and therefore the entire process requires attention to details in order to achieve patients protection. This project reviews eight case studies involving accidents that occurred during the process of therapy delivery. Professionalism in case one and two was not practiced in that in case one medical physicist failed to calculate decay data instead relied on incorrect decay graph thus giving wrong dose. While in case two a wrong TPS was approved following a formal written procedure due to new technology. In case three and seven there was a software malfunction due to uniformed choice of TPS and in case four a computer file was not updated in the TPS while in eight the failure is inter look system led to patients recieving high dose than was prescribed. Calibration in case five and six was due to wrong actions in both repairs and interpretation of treatment time than the overdose to patient. The lessen learnt seeks to act as a checklist for ensuring patient protection in radiotherapy and prevention of future accidents. (au)

  9. Online measurement of electron beam parameters by image processing

    International Nuclear Information System (INIS)

    Tyagi, Y.; Puntambekar, T.A.

    2010-01-01

    The basic image acquisition software which was developed earlier has been recently upgraded to support online measurement of beam centroid, beam height and beam width from the diagnostic devices namely fluorescent screen beam profile monitors and beam slit monitor installed in Transport Line -1(TL-1) at Indus Accelerator Complex at RRCAT, Indore. The online measurement of these electron beam parameters has helped the Indus operation team to take necessary corrective action if required before injection of the electron beam into booster synchrotron. This paper presents the methodology adopted for online measurement of above parameters in the software. (author)

  10. Beam characterisation of the KIRAMS electron microbeam system

    International Nuclear Information System (INIS)

    Sun, G. M.; Kim, E. H.; Song, K. B.; Jang, M.

    2006-01-01

    An electron microbeam system has been installed at the Korea Inst. of Radiological and Medical Sciences (KIRAMS) for use in radiation biology studies. The electron beam is produced from a commercial electron gun, and the beam size is defined by a 5 μm diameter pinhole. Beam energy can be varied in the range of 1-100 keV, covering a range of linear energy transfer from 0.4 to 12.1 keV μm -1 . The micrometer-sized electron beam selectively irradiates cells cultured in a Mylar-bottomed dish. The positioning of target cells one by one onto the beam exit is automated, as is beam shooting. The electron beam entering the target cells has been calibrated using a Passivated Implanted Planar Silicon (PIPS) detector. This paper describes the KIRAMS microbeam cell irradiation system and its beam characteristics. (authors)

  11. Development of picosecond pulsed electron beam monitor

    International Nuclear Information System (INIS)

    Hosono, Y.; Nakazawa, M.; Ueda, T.; Kobayasi, T.; Yosida, Y.; Ohkuma, J.; Okuda, S.; Suemine, S.

    1993-01-01

    For the picosecond pulsed electron beam of a linear accelerator a simple monitor using an electric connector has been developed which is constructed with SMA, BNC, N type electric connector through pipe (inner diameter = 50 mm or 100 mm). Under the measurement conditions of peak current (26A-900A) and narrow pulse width (Pw = 10 ps(FWHM), Pw = 30 ps(FWHM)), the following characteristics of this monitor were obtained, (A) rise time is less than 25 ps (B) the amplitude of the monitor output pulse is proportional directly to the area of cross section of the electrode. (author)

  12. Monte Carlo calculation of scattered radiation from applicators in low energy clinical electron beams

    International Nuclear Information System (INIS)

    Jabbari, N.; Hashemi-Malayeri, B.; Farajollahi, A. R.; Kazemnejad, A.

    2007-01-01

    In radiotherapy with electron beams, scattered radiation from an electron applicator influences the dose distribution in the patient. The contribution of this radiation to the patient dose is significant, even in modern accelerators. In most of radiotherapy treatment planning systems, this component is not explicitly included. In addition, the scattered radiation produced by applicators varies based on the applicator design as well as the field size and distance from the applicators. The aim of this study was to calculate the amount of scattered dose contribution from applicators. We also tried to provide an extensive set of calculated data that could be used as input or benchmark data for advanced treatment planning systems that use Monte Carlo algorithms for dose distribution calculations. Electron beams produced by a NEPTUN 10PC medical linac were modeled using the BEAMnrc system. Central axis depth dose curves of the electron beams were measured and calculated, with and without the applicators in place, for different field sizes and energies. The scattered radiation from the applicators was determined by subtracting the central axis depth dose curves obtained without the applicators from that with the applicator. The results of this study indicated that the scattered radiation from the electron applicators of the NEPTUN 10PC is significant and cannot be neglected in advanced treatment planning systems. Furthermore, our results showed that the scattered radiation depends on the field size and decreases almost linearly with depth. (author)

  13. Beam lifetime measurement and analysis in Indus-2 electron ...

    Indian Academy of Sciences (India)

    In this paper, the beam lifetime measurement and its theoretical analysis are presented using measured vacuum pressure and applied radio frequency (RF) cavity voltage in Indus-2 electron storage ring at 2 GeV beam energy. Experimental studies of the effect of RF cavity voltage and bunched beam filling pattern on beam ...

  14. Influence of bone and fat on dose distribution in electron beams in a semi-infinite medium

    International Nuclear Information System (INIS)

    Sordo, A.

    1983-12-01

    Hitherto, physical and theoretical aspects of the influence of heterogeneities in radiotherapy by electron beams had not been enough considered. We have developped an experimental method which permitted us to analyze the effect of the hard bone and the fat on the depth dose distributions when an infinite medium is irradiated by high energy electron beams. We have incorporated the KR. HOGSTROM's algorithm in a treatment planning system (TP11; AECL). This algorithm sums the dose distribution of individual pencil beams. A comparison between calculated and measured isodose lines obtained in a heterogeneous medium, shows us the performance and limits of this algorithm [fr

  15. Internal hemipelvectomy with intraoperative and external beam radiotherapy in the limb-sparing treatment of a pelvic girdle chondrosarcoma

    NARCIS (Netherlands)

    Hoekstra, HJ; Szabo, BG

    The case of a patient with an extensive pelvic girdle chondrosarcoma treated with internal hemipelvectomy and intraoperative radiotherapy, followed by adjuvant high-dose external beam radiotherapy, with a successful attempt in achieving long-term local tumor control and limb-sparing treatment is

  16. Importance of daily electronic portal imaging in radiotherapy

    International Nuclear Information System (INIS)

    Bell, L. J.; Shakespeare, T. P.; Willis, A.

    2008-01-01

    Full text: An audit was conducted on 20 randomly selected patients who had daily electronic portal imaging during the course of their radiotherapy treatment. The daily images were reviewed to determine whether they were within tolerance according to departmental protocol. If they were not, the actions that were taken were documented. Four treatment areas (spine, chest, breast and prostate) were compared among five patients belonging to each of these categories. The patients were also categorized according to their treatment intent (radical or palliative). A total of 889 electronic portal images of 475 fractions were audited and 33.5% of all fractions were outside tolerance. It was found that 95% of patients needed an action during their treatment and 80% of the patients needed a treatment centre move during the course of their treatment. We found that errors occurred throughout the treatment and it was not possible to predict patients who could have daily imaging omitted. Concordance between radiation therapists and radiation oncologists for identification of error was also investigated. Despite the use of familiar electronic portal imaging protocols, image reviewers (radiation therapists and radiation oncologists) disagreed in interpretation 10% of the time. Our results support the hypothesis that daily imaging may be a useful tool for patients undergoing radiotherapy and that imaging may be ideally carried out before each fraction. Image assessments would be ideally carried out by a team approach, with all images reviewed by both radiation therapists and radiation oncologists. This approach has significant resource implications and may require review of current Medicare and Health Program Grant reimbursements.

  17. Poster - Thur Eve - 27: Scattering foil redesign for modulated electron radiotherapy.

    Science.gov (United States)

    Connell, T; Seuntjens, J

    2012-07-01

    This work serves to build on existing work that discussed the advantages of removing the scattering foil from the beamline for modulated electron radiotherapy (MERT) much like flattening filter-free beams in photon IMRT. Due to concerns about the ability of the accelerators transmission ionization chamber to function normally with narrow, minimally-scattered beams as well as a limited maximum field size, this study focused on the design of a new custom scattering foil that was optimized for MERT applications. Different foil parameters such as material, thickness and shape were investigated to produce a minimally scattered beam, as opposed to a flat beam in the case of the clinical foil, while preserving the dosimetric benefits of a reduced thickness foil such as dramatically higher dose rate and reduced photon contamination in the bremsstrahlung tail. Using a Monte Carlo model that was verified against measured data, fluence profiles at the level of the transmission ionization chamber were produced and analyzed for all foil configurations, as well as PDDs and profiles in a water phantom. It was found that a simple foil of slab geometry made of low to medium Z material with the thickness determined by the maximum desirable field size and chosen electron energy produced a sufficiently scattered beam that maintained the dosimetric advantages of a scattering-foil-free beamline. These new foils, when applied to MERT, have the advantage of reducing treatment time due to higher dose rates and reducing dose to healthy tissue due to reduced dose in the bremsstrahlung tail. © 2012 American Association of Physicists in Medicine.

  18. Postoperative External Beam Radiotherapy for Retroperitoneal Soft Tissue Sarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Na Yong; Kim, Il Han; Choi, Jin Hwa; Park, Charn Il [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-09-15

    To evaluate the clinical outcomes and prognostic factors in retroperitoneal soft tissue sarcomas treated by postoperative radiotherapy. The records of 23 patients with retroperitoneal soft tissue sarcomas, who underwent postoperative radiotherapy between 1985 and 2003, were analyzed. The median follow-up period was 77 months (range, 8-240 months). A total of 21 patients presented with primary disease, and two patients presented with recurrent disease. Liposarcomas and leiomyosarcomas represented 78% of the diagnosed tumor cases. Moreover, 17 cases were of high grade (grade 2 or 3). The median tumor size was 13 cm (range, 3-50 cm). Complete excision was achieved in 65% of patients. The median radiation dose was 50.4 Gy (range, 45.0 to 59.4 Gy), with conventional fractionation. The 5-year overall, local recurrence-free, and distant metastasis-free survival rates were 68%, 58%, and 71%, respectively. Eleven patients experienced local recurrence, while 9 patients experienced distant metastasis. The most common site for distant metastasis was the liver. A univariate analysis revealed that adjacent organ invasion and age (>60 years) as the significant risk factors contributing to the prediction of poor overall survival. Moreover, multivariate analyses indicated that adjacent organ invasion remained significantly associated with a higher risk of death. In addition, patient age (>60 years) was the other identified risk factor for local recurrence by univariate and multivariate analyses. Except for one case of grade 3 diarrhea, no patient suffered grade 3 or higher complications. Our results were comparable to previous reports in that adjacent organ invasion and patient age (>60 years) were significant predictors of poor survival and tumor recurrence, respectively.

  19. Analysis of Beam-Beam Kink Instability in a Linac-Ring Electron-Ion Collider

    International Nuclear Information System (INIS)

    V. Lebedev; J. Bisognano; R. Li; B. Yunn

    2001-01-01

    A linac-ring collision scheme was considered in recent proposals of electron-gold colliders (eRHIC) and polarized-electron light-ion colliders (EPIC). The advantages of using an energy-recovered linac for the electron beam is that it avoids the limitation of beam-beam tune shift inherent in a storage ring, pertains good beam quality and easy manipulation of polarization. However, the interaction of the ion beam in the storage ring with the electron beam from the linac acts analogously to a transverse impedance, and can induce unstable behavior of the ion beam similar to the strong head-tail instability. In this paper, this beam-beam kink instability with head-tail effect is analyzed using the linearized Vlasov equation, and the threshold of transverse mode coupling instability is obtained

  20. Radiotherapy

    International Nuclear Information System (INIS)

    Prosnitz, L.R.; Kapp, D.S.; Weissberg, J.B.

    1983-01-01

    This review highlights developments over the past decade in radiotherapy and attempts to summarize the state of the art in the management of the major diseases in which radiotherapy has a meaningful role. The equipment, radiobiology of radiotherapy and carcinoma of the lung, breast and intestines are highlighted

  1. Investigation of the added value of high-energy electrons in intensity-modulated radiotherapy: four clinical cases

    International Nuclear Information System (INIS)

    Korevaar, Erik W.; Huizenga, Henk; Loef, Johan; Stroom, Joep C.; Leer, Jan Willem H.; Brahme, Anders

    2002-01-01

    Purpose: Intensity-modulated radiotherapy (IMRT) with photon beams is currently pursued in many clinics. Theoretically, inclusion of intensity- and energy-modulated high-energy electron beams (15-50 MeV) offers additional possibilities to improve radiotherapy treatments of deep-seated tumors. In this study the added value of high-energy electron beams in IMRT treatments was investigated. Methods and Materials: In a comparative treatment planning study, conventional treatment plans and various types of IMRT plans were constructed for four clinical cases (cancer of the bladder, pancreas, chordoma of the sacrum, and breast). The conventional plans were used for the actual treatment of the patients. The IMRT plans were optimized using the Orbit optimization code (Loef et al., 2000) with a radiobiologic objective function. The IMRT plans were either photon or combined electron and photon beam plans, with or without dose homogeneity constraints assuming standard or increased radiosensitivities of organs at risk. Results: Large improvements in expected treatment outcome are found using IMRT plans compared to conventional plans, but differences in tumor control probability (TCP) and normal tissue complication probabilities (NTCP) values between IMRT plans with and without electrons are small. However, the use of electrons improves the dose-volume histograms for organs at risk, especially at lower dose levels (e.g., 0-40 Gy). Conclusions: This preliminary study indicates that addition of higher energy electrons to IMRT can only marginally improve treatment outcome for the selected cases. The dose-volume histograms of organs at risk show improvements for IMRT with higher energy electrons, which may reduce tumor induction but does not substantially reduce NTCP

  2. External beam radiotherapy for palliation of pain from metastatic carcinoma of the prostate

    International Nuclear Information System (INIS)

    Benson, R.C. Jr.; Hasan, S.M.; Jones, A.G.; Schlise, S.

    1982-01-01

    Radiotherapy often is used for palliation of bone pain from metastatic cancer of the prostate but an objective evaluation of its efficacy in a large series of patients is unavailable. We report the results of external beam irradiation in 62 patients who had bone pain secondary to stage D carcinoma of the prostate. The variables used to judge pain before and after radiotherapy included subjective evaluation of pain, status of activity and quantitation of analgesic use. Complete relief of pain was achieved in 26 patients (42 per cent), partial relief in 22 (35 per cent) and no relief in 14 (23 per cent). On the basis of our experience external beam irradiation is useful palliative therapy for pain from metastatic cancer of the prostate

  3. Establishing the impact of temporary tissue expanders on electron and photon beam dose distributions.

    Science.gov (United States)

    Asena, A; Kairn, T; Crowe, S B; Trapp, J V

    2015-05-01

    This study investigates the effects of temporary tissue expanders (TTEs) on the dose distributions in breast cancer radiotherapy treatments under a variety of conditions. Using EBT2 radiochromic film, both electron and photon beam dose distribution measurements were made for different phantoms, and beam geometries. This was done to establish a more comprehensive understanding of the implant's perturbation effects under a wider variety of conditions. The magnetic disk present in a tissue expander causes a dose reduction of approximately 20% in a photon tangent treatment and 56% in electron boost fields immediately downstream of the implant. The effects of the silicon elastomer are also much more apparent in an electron beam than a photon beam. Evidently, each component of the TTE attenuates the radiation beam to different degrees. This study has demonstrated that the accuracy of photon and electron treatments of post-mastectomy patients is influenced by the presence of a tissue expander for various beam orientations. The impact of TTEs on dose distributions establishes the importance of an accurately modelled high-density implant in the treatment planning system for post-mastectomy patients. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Industrial wastewater treatment with electron beam

    International Nuclear Information System (INIS)

    Han, Bumsoo; Ko, Jaein; Kim, Jinkyu; Kim, Yuri; Chung, Wooho

    2001-01-01

    Global withdrawals of water to satisfy human demands have grown dramatically in this century. Between 1900 and 1945, water consumption increased by over six times, more than double the rate of population growth. This rapid growth in water demand is due to the increasing reliance on irrigation to achieve food security, the growth of industrial uses, and the increasing use per capita for domestic purposes. Given the seriousness of the situation and future risk of crises, there is an urgent need to develop the water-efficient technologies including economical treatment methods of wastewater and polluted water. In the Central Research Institute of Samsung Heavy Industries (SHI), many industrial wastewater including leachate from landfill area, wastewater from papermill, dyeing complex, petrochemical processes, etc. are under investigation with electron beam irradiation. For the study of treating dyeing wastewater combined with conventional facilities, an electron beam pilot plant for treating 1,000m 3 /day of wastewater from 80,000m 3 /day of total dyeing wastewater has constructed and operated in Taegu Dyeing Industrial Complex. A commercial plant for re-circulation of wastewater from Papermill Company is also designed for S-paper Co. in Cheongwon City, and after the successful installation, up to 80% of wastewater could be re-used in paper producing process. (author)

  5. Electron beam irradiation technology for environmental conservation

    International Nuclear Information System (INIS)

    Tokunaga, Okihiro; Arai, Hidehiko; Hashimoto, Shoji

    1992-01-01

    This paper reviews research and development of application of electron beam (EB) irradiation technology for treatment of flue gas and waste water, and for disinfection of sewage sludge. Feasibility studies on EB purification of flue gases have been performed with pilot-scale experiments in Japan, the USA and Germany, and is being carried out in Poland for flue gases from iron-sintering furnaces or coal burning boilers. Based on results obtained by experiments using simulated flue gas, pilot scale test for treatment of flue gas of low-sulfur containing coal combustion has recently started in Japan. Organic pollutants in waste water and ground water have been found to be decomposed by EB irradiation. Synergetic effect of EB irradiation and ozone addition was found to improve the decomposition efficiency. Electron beam irradiation technology for disinfection of water effluent from water treatment plants was found to avoid formation of chlorinated organic compounds which are formed in using chlorine. Efficient process for composting of sewage sludge disinfected by EB irradiation has been developed by small scale and pilot scale experiments. In the new process, disinfection by EB irradiation and composing can be done separately and optimum temperature for composting can be, therefore, selected to minimize period of composting. (author)

  6. Spin polarisation with electron Bessel beams

    Energy Technology Data Exchange (ETDEWEB)

    Schattschneider, P., E-mail: schattschneider@ifp.tuwien.ac.at [Institut für Festkörperphysik, Technische Universität Wien, A-1040 Wien (Austria); USTEM, Technische Universität Wien, A-1040 Wien (Austria); Grillo, V. [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); CNR-IMEM, Parco delle Scienze 37a, I-43100 Parma (Italy); Aubry, D. [Centrale Supelec, MSSMast CNRS 8579, F-92295 Châtenay-Malabry (France)

    2017-05-15

    The theoretical possibility to use an electron microscope as a spin polarizer is studied. It turns out that a Bessel beam passing a standard magnetic objective lens is intrinsically spin polarized when post-selected on-axis. In the limit of infinitely small detectors, the spin polarisation tends to 100 %. Increasing the detector size, the polarisation decreases rapidly, dropping below 10{sup −4} for standard settings of medium voltage microscopes. For extremely low voltages, the Figure of Merit increases by two orders of magnitude, approaching that of existing Mott detectors. Our findings may lead to new desings of spin filters, an attractive option in view of its inherent combination with the electron microscope, especially at low voltage. - Highlights: • TEM round magnetic lenses can act as spin polarizers when a Bessel beam is sent through. • This is found on theoretical grounds and demonstrated numerically for a few cases. • The effect is small, but can reach a Figure of Merit similar to existing Mott detectors. • This opens the possibility to construct nanometer-sized spin filters or detectors.

  7. Polarization of a stored electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Chao, A.W.

    1981-07-01

    Synchrotron radiation by a point charge is a familiar subject in classical electrodynamics. Perhaps less familiar are some quantum mechanical corrections to the classical results. Some of those quantum aspects of synchrotron radiation are described. One of the quantum effects leads to the expectation that electrons in a storage ring will polarize themselves to 92% - a surprisingly high value. A semi-classical derivation of the quantum effects is given. An effort has been made to minimize the need of using quantum mechanics. Results are put together to derive a final expression of beam polarization. Conditions under which the expected 92% polarization is destroyed are found and attributed to depolarization resonances. The various depolarization mechanisms are first illustrated by an idealized example and then systematically treated by a matrix formalism. It is shown that the strength of depolarization is specified by a key quantity called the spin chromaticity. Finally as an application of the obtained results, an estimate of the achievable level of beam polarization for two existing electron storage rings, SPEAR and PEP, is given.

  8. Radiation processing of carrageenan using electron beam

    International Nuclear Information System (INIS)

    Abad, L.V.; Aranilla, C.T.; Relleve, L.; Dela Rosa, A.M.

    2005-01-01

    Electron beam accelerator has been widely employed in the modification of natural polymers for the development of materials used in biomedical and agricultural applications. The carrageenans are among these materials that show a vast potential for these types of applications. Previous studies at the Philippine Nuclear Research Institute focused on the utilization of gamma radiation to modify the carrageenans. Radiation degradation of carrageenan found valuable use as plant growth promoter. Hydrogels for burn dressing using blends of carrageenan and synthetic polymers have also been made using gamma radiation. While previous studies have been focused on the use of gamma radiation to modify the carrageenans, recent studies expanded the technology to electron beam. Concretely, researches are along the following two areas: a) Degradation studies of aqueous carrageenan using the LEEB and b) Preparation of blend polysaccharide derivatives such as carboxymethylcellulose (CMC), and hydroxypropylcellulose (HPC) with kappa-carrageenan (KC) by EB radiation. These works were done at the Takasaki Radiation Chemistry Research Establishment (TRCRE) by two PNRI colleagues under the nuclear researcher exchange program of the Japan Ministry of Education, Culture, Sports, Science and Technology (MEXT). The first area had already been reported and discussed in the last project meeting held in Malaysia. (author)

  9. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  10. Verification of the pure alanine in PMMA tube dosimeter applicability for dosimetry of radiotherapy photon beams: a feasibility study.

    Science.gov (United States)

    Al-Karmi, Anan M; Ayaz, Ali Asghar H; Al-Enezi, Mamdouh S; Abdel-Rahman, Wamied; Dwaikat, Nidal

    2015-09-01

    Alanine dosimeters in the form of pure alanine powder in PMMA plastic tubes were investigated for dosimetry in a clinical application. Electron paramagnetic resonance (EPR) spectroscopy was used to measure absorbed radiation doses by detection of signals from radicals generated in irradiated alanine. The measurements were performed for low-dose ranges typical for single-fraction doses often used in external photon beam radiotherapy. First, the dosimeters were irradiated in a solid water phantom to establish calibration curves in the dose range from 0.3 to 3 Gy for 6 and 18 MV X-ray beams from a clinical linear accelerator. Next, the dosimeters were placed at various locations in an anthropomorphic pelvic phantom to measure the dose delivery of a conventional four-field box technique treatment plan to the pelvis. Finally, the doses measured with alanine dosimeters were compared against the doses calculated with a commercial treatment planning system (TPS). The results showed that the alanine dosimeters have a highly sensitive dose response with good linearity and no energy dependence in the dose range and photon beams used in this work. Also, a fairly good agreement was found between the in-phantom dose measurements with alanine dosimeters and the TPS dose calculations. The mean value of the ratios of measured to calculated dose values was found to be near unity. The measured points in the in-field region passed dose-difference acceptance criterion of 3% and those in the penumbral region passed distance-to-agreement acceptance criterion of 3 mm. These findings suggest that the pure alanine powder in PMMA tube dosimeter is a suitable option for dosimetry of radiotherapy photon beams.

  11. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  12. Interpenetrating Polymer Network (IPN) Adhesives for Electron Beam Cure

    National Research Council Canada - National Science Library

    Sands, James

    2000-01-01

    Electron beam (e-beam)-processed polymer adhesives have historically performed poorly compared to traditional adhesive technologies due to a lack of toughness engineered into these new types of adhesive materials...

  13. An algorithm for fast beam angle selection in intensity modulated radiotherapy.

    Science.gov (United States)

    Vaitheeswaran, R; Narayanan, V K Sathiya; Bhangle, Janhavi R; Nirhali, Amit; Kumar, Namitha; Basu, Sumit; Maiya, Vikram

    2010-12-01

    This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT). The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profile perturbation score (BIPPS)" is used for ranking the beam angles. The BIPPS-based beam angle ranking implicitly accounts for the dose-volume effects of the involved structures. A simulated phantom case with obvious optimal beam angles is used to verify the validity of the presented technique. In addition, the efficiency of the algorithm was examined in three clinical cases (prostate, pancreas, and head and neck) in terms of DVH and dose distribution. In all cases, the judgment of the algorithm's efficiency was based on the comparison between plans with equidistant beams (equal-angle-plan) and plans with beams obtained using the algorithm (suitable-angle-plan). It is observed from the study that the beam angle ranking function over BIPPS instantly picks up a suitable set of beam angles for a specific case. It takes only about 15 min for choosing the suitable beam angles even for the most complicated cases. The DVHs and dose distributions confirm that the proposed algorithm can efficiently reduce the mean or maximum dose to OARs, while guaranteeing the target coverage and dose uniformity. On the average, about 17% reduction in the mean dose to critical organs, such as rectum, bladder, kidneys and parotids, is observed. Also, about 12% (averaged) reduction in the maximum dose to critical organs (spinal cord) is observed in the clinical cases presented in this study. This study demonstrates that the algorithm can be effectively applied to IMRT scenarios to get fast and case specific beam angle configurations.

  14. Constrained customization of non-coplanar beam orientations in radiotherapy of brain tumours

    International Nuclear Information System (INIS)

    Rowbottom, C.G.; Oldham, M.; Webb, S.

    1999-01-01

    A methodology for the constrained customization of non-coplanar beam orientations in radiotherapy treatment planning has been developed and tested on a cohort of five patients with tumours of the brain. The methodology employed a combination of single and multibeam cost functions to produce customized beam orientations. The single-beam cost function was used to reduce the search space for the multibeam cost function, which was minimized using a fast simulated annealing algorithm. The scheme aims to produce well-spaced, customized beam orientations for each patient that produce low dose to organs at risk (OARs). The customized plans were compared with standard plans containing the number and orientation of beams chosen by a human planner. The beam orientation constraint-customized plans employed the same number of treatment beams as the standard plan but with beam orientations chosen by the constrained-customization scheme. Improvements from beam orientation constraint-customization were studied in isolation by customizing the beam weights of both plans using a dose-based downhill simplex algorithm. The results show that beam orientation constraint-customization reduced the maximum dose to the orbits by an average of 18.8 (±3.8, 1SD)% and to the optic nerves by 11.4 (±4.8, 1SD)% with no degradation of the planning target volume (PTV) dose distribution. The mean doses, averaged over the patient cohort, were reduced by 4.2 (±1.1, 1SD)% and 12.4 (±3.1 1SD)% for the orbits and optic nerves respectively. In conclusion, the beam orientation constraint-customization can reduce the dose to OARs, for few-beam treatment plans, when compared with standard treatment plans developed by a human planner. (author)

  15. Study of the alignment of X radiation beam for calibration of chambers used in radiotherapy

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Peixoto, Jose Guilherme Pereira

    2014-01-01

    The activities developed in radiotherapy, diagnostic radiology and radiation safety, require that the metrological parameters involving these activities have on its results a high degree of reliability, to ensure traceability. To meet the existing demand in Brazil, the National Metrology Laboratory of Ionizing Radiation - LNMRI - is deploying a new tube X-ray beams used in the calibration of the standard rooms, which serve to quality control in hospitals, clinics and industry. (author)

  16. Monte Carlo treatment planning with modulated electron radiotherapy: framework development and application

    Science.gov (United States)

    Alexander, Andrew William

    optimization algorithms are demonstrated. We investigated the clinical significance of MERT on spinal irradiation, breast boost irradiation, and a head and neck sarcoma cancer site using several parameters to analyze the treatment plans. Finally, we investigated the idea of mixed beam photon and electron treatment planning. Photon optimization treatment planning tools were included within the MERT planning toolkit for the purpose of mixed beam optimization. In conclusion, this thesis work has resulted in the development of an advanced framework for photon and electron Monte Carlo treatment planning studies and the development of an inverse planning system for photon, electron or mixed beam radiotherapy (MBRT). The justification and validation of this work is found within the results of the planning studies, which have demonstrated dosimetric advantages to using MERT or MBRT in comparison to clinical treatment alternatives.

  17. Particle-beam accelerators for radiotherapy and radioisotopes

    Science.gov (United States)

    Boyd, T. J., Jr.; Crandall, K. R.; Hamm, R. W.; Hansborough, L. D.; Hoeberling, R. F.; Jameson, R. A.; Knapp, E. A.; Mueller, D. W.; Potter, J. M.; Stokes, R. H.

    The philosophy used in developing the PIGMI (pion generator for medical irradiation) technology was that the parameters chosen for physics research machines are not necessarily the right ones for a dedicated therapy or radioisotope machine. In particular, the beam current and energy can be optimized, and the design should emphasize minimum size, simplicity and reliability of operation, and economy in capital and operating costs. A major part of achieving these goals lay in raising the operating frequency and voltage gradient of the accelerator, which shrinks the diameter and length of the components. Several other technical innovations resulted in major system improvements. One of these is a radically new type of accelerator structure named the radio frequency quadrupole accelerator. This allowed the elimination of the large, complicated ion source used in previous ion accelerators, and a very high quality accelerated beam. Also, by using advanced permanent magnet materials to make the focusing elements, the system becomes much simpler. Other improvements are described.

  18. Effects of physics change in Monte Carlo code on electron pencil beam dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Toutaoui, Abdelkader, E-mail: toutaoui.aek@gmail.com [Departement de Physique Medicale, Centre de Recherche Nucleaire d' Alger, 2 Bd Frantz Fanon BP399 Alger RP, Algiers (Algeria); Khelassi-Toutaoui, Nadia, E-mail: nadiakhelassi@yahoo.fr [Departement de Physique Medicale, Centre de Recherche Nucleaire d' Alger, 2 Bd Frantz Fanon BP399 Alger RP, Algiers (Algeria); Brahimi, Zakia, E-mail: zsbrahimi@yahoo.fr [Departement de Physique Medicale, Centre de Recherche Nucleaire d' Alger, 2 Bd Frantz Fanon BP399 Alger RP, Algiers (Algeria); Chami, Ahmed Chafik, E-mail: chafik_chami@yahoo.fr [Laboratoire de Sciences Nucleaires, Faculte de Physique, Universite des Sciences et de la Technologie Houari Boumedienne, BP 32 El Alia, Bab Ezzouar, Algiers (Algeria)

    2012-01-15

    electrons. - Highlights: > Pencil beams can be generated by Monte Carlo simulation of electron transport and/or electron dose calculation in radiotherapy. > A comparison of a series of pencil beam dose distributions scored in cylindrical geometry, for electron energies between 1 MeV and 50 MeV calculated with EGS4 and EGSnrc was performed. > Radial dose distributions show agreement within 10% between doses calculated by the two codes for voxels closer to the pencil beam central axis, while the differences are up to 30% for longer distances. > These differences may be mainly attributed to the different multiple scattering for electron transport adopted in these two codes and the inclusion of spin effect.

  19. Effects of physics change in Monte Carlo code on electron pencil beam dose distributions

    International Nuclear Information System (INIS)

    Toutaoui, Abdelkader; Khelassi-Toutaoui, Nadia; Brahimi, Zakia; Chami, Ahmed Chafik

    2012-01-01

    electrons. - Highlights: → Pencil beams can be generated by Monte Carlo simulation of electron transport and/or electron dose calculation in radiotherapy. → A comparison of a series of pencil beam dose distributions scored in cylindrical geometry, for electron energies between 1 MeV and 50 MeV calculated with EGS4 and EGSnrc was performed. → Radial dose distributions show agreement within 10% between doses calculated by the two codes for voxels closer to the pencil beam central axis, while the differences are up to 30% for longer distances. → These differences may be mainly attributed to the different multiple scattering for electron transport adopted in these two codes and the inclusion of spin effect.

  20. Unveiling the orbital angular momentum and acceleration of electron beams.

    Science.gov (United States)

    Shiloh, Roy; Tsur, Yuval; Remez, Roei; Lereah, Yossi; Malomed, Boris A; Shvedov, Vladlen; Hnatovsky, Cyril; Krolikowski, Wieslaw; Arie, Ady

    2015-03-06

    New forms of electron beams have been intensively investigated recently, including vortex beams carrying orbital angular momentum, as well as Airy beams propagating along a parabolic trajectory. Their traits may be harnessed for applications in materials science, electron microscopy, and interferometry, and so it is important to measure their properties with ease. Here, we show how one may immediately quantify these beams' parameters without need for additional fabrication or nonstandard microscopic tools. Our experimental results are backed by numerical simulations and analytic derivation.

  1. TOPICAL REVIEW: Dose calculations for external photon beams in radiotherapy

    Science.gov (United States)

    Ahnesjö, Anders; Mania Aspradakis, Maria

    1999-11-01

    Dose calculation methods for photon beams are reviewed in the context of radiation therapy treatment planning. Following introductory summaries on photon beam characteristics and clinical requirements on dose calculations, calculation methods are described in order of increasing explicitness of particle transport. The simplest are dose ratio factorizations limited to point dose estimates useful for checking other more general, but also more complex, approaches. Some methods incorporate detailed modelling of scatter dose through differentiation of measured data combined with various integration techniques. State-of-the-art methods based on point or pencil kernels, which are derived through Monte Carlo simulations, to characterize secondary particle transport are presented in some detail. Explicit particle transport methods, such as Monte Carlo, are briefly summarized. The extensive literature on beam characterization and handling of treatment head scatter is reviewed in the context of providing phase space data for kernel based and/or direct Monte Carlo dose calculations. Finally, a brief overview of inverse methods for optimization and dose reconstruction is provided.

  2. Intensive Ion Beam In Storage Rings With Electron Cooling

    CERN Document Server

    Korotaev, Yu V; Kamerdjiev, V; Maier, R; Meshkov, I; Noda, K; Prasuhn, D; Sibuya, S; Sidorin, A; Stein, H J; Stockhorst, H; Syresin, E M; Uesugi, T

    2004-01-01

    Results of experimental studies of the electron cooling of a proton beam at COSY (Juelich, Germany) and an ion beam at HIMAC (Chiba, Japan) are presented. Intensity of the ion beam is limited by two general effects: particle loss directly after the injection and development of instability in a deep cooled ion beam. Methods of the instability suppression, which allow increasing the cooled beam intensity, are described.

  3. Measurement of electron beams profile of pierce type electron source using sensor of used Tv tube

    International Nuclear Information System (INIS)

    Darsono; Suhartono; Suprapto; Elin Nuraini

    2015-01-01

    The measurement of an electron beam profile has been performed using electron beam monitor based on method of phosphorescent materials. The main components of the electron beam monitor consists of a fluorescent sensor using a used Tv tube, CCTV camera to record images on a Tv screen, video adapter as interface between CCTV and laptop, and the laptop as a viewer and data processing. Two Pierce-type electron sources diode and triode was measured the shape of electron beam profile in real time. Results of the experiments showed that the triode electron source of Pierce type gave the shape of electron beam profiles better than that of the diode electron source .The anode voltage is not so influential on the beam profile shape. The focused voltage in the triode electron source is so influence to the shape of the electron beam profile, but above 5 kV no great effect. It can be concluded that the electron beam monitor can provide real time observations and drawings shape of the electron beam profile displayed on the used Tv tube glass screen which is the real picture of the shape of the electron beam profile. Triode electron source produces a better electron beam profile than that of the diode electron source. (author)

  4. Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy

    International Nuclear Information System (INIS)

    Grills, Inga S.; Hugo, Geoffrey; Kestin, Larry L.; Galerani, Ana Paula; Chao, K. Kenneth; Wloch, Jennifer; Yan Di

    2008-01-01

    Purpose: To determine treatment accuracy and margins for stereotactic lung radiotherapy with and without cone-beam CT (CBCT) image guidance. Methods and Materials: Acquired for the study were 308 CBCT of 24 patients with solitary peripheral lung tumors treated with stereotactic radiotherapy. Patients were immobilized in a stereotactic body frame (SBF) or alpha-cradle and treated with image guidance using daily CBCT. Four (T1) or five (T2/metastatic) 12-Gy fractions were prescribed to the planning target volume (PTV) edge. The PTV margin was ≥5 mm depending on a pretreatment estimate of tumor excursion. Initial daily setup was according to SBF coordinates or tattoos for alpha-cradle cases. A CBCT was performed and registered to the planning CT using soft tissue registration of the target. The initial setup error/precorrection position, was recorded for the superior-inferior, anterior-posterior, and medial-lateral directions. The couch was adjusted to correct the tumor positional error. A second CBCT verified tumor position after correction. Patients were treated in the corrected position after the residual errors were ≤2 mm. A final CBCT after treatment assessed intrafraction tumor displacement. Results: The precorrection systematic (Σ) and random errors (σ) for the population ranged from 2-3 mm for SBF and 2-6 mm for alpha-cradle patients; postcorrection errors ranged from 0.4-1.0 mm. Calculated population margins were 9 to 13 mm (SBF) and 10-14 mm (cradle) precorrection, 1-2 mm (SBF), and 2-3 mm (cradle) postcorrection, and 2-4 mm (SBF) and 2-5 mm (cradle) posttreatment. Conclusions: Setup for stereotactic lung radiotherapy using a SBF or alpha-cradle alone is suboptimal. CBCT image guidance significantly improves target positioning and substantially reduces required target margins and normal tissue irradiation

  5. Treatment planning considerations in contrast-enhanced radiotherapy: energy and beam aperture optimization

    Energy Technology Data Exchange (ETDEWEB)

    Garnica-Garza, H M, E-mail: hgarnica@cinvestav.mx [Centro de Investigacion y de Estudios Avanzados del Instituto Politecnico Nacional Unidad Monterrey, Via del Conocimiento 201 Parque de Investigacion e Innovacion Tecnologica, Apodaca NL CP 66600 (Mexico)

    2011-01-21

    It has been shown that the use of kilovoltage x-rays in conjunction with a contrast agent incorporated into the tumor can lead to acceptable treatment plans with regard to the absorbed dose distribution produced in the target as well as in the tissue and organs at risk surrounding it. In this work, several key aspects related to the technology and irradiation techniques necessary to clinically implement this treatment modality are addressed by means of Monte Carlo simulation. The Zubal phantom was used to model a prostate radiotherapy treatment, a challenging site due to the depth of the prostate and the presence of bony structures that must be traversed by the x-ray beam on its way to the target. It is assumed that the concentration levels of the enhancing agent present in the tumor are at or below 10 mg per 1 g of tissue. The Monte Carlo code PENELOPE was used to model a commercial x-ray tube having a tungsten target. X-ray energy spectra for several combinations of peak electron energy and added filtration were obtained. For each energy spectrum, a treatment plan was calculated, with the PENELOPE Monte Carlo code, by modeling the irradiation of the patient as 72 independent conformal beams distributed at intervals of 5{sup 0} around the phantom in order to model a full x-ray source rotation. The Cimmino optimization algorithm was then used to find the optimum beam weight and energy for different treatment strategies. It is shown that for a target dose prescription of 72 Gy covering the whole tumor, the maximum rectal wall and bladder doses are kept below 52 Gy for the largest concentration of contrast agent of 10 mg per 1 g of tissue. It is also shown that concentrations of as little as 5 mg per 1 g of tissue also render dose distributions with excellent sparing of the organs at risk. A treatment strategy to address the presence of non-uniform distributions of the contrast agent in the target is also modeled and discussed.

  6. Measuring the electron beam energy in a magnetic bunch compressor

    International Nuclear Information System (INIS)

    Hacker, Kirsten

    2010-09-01

    Within this thesis, work was carried out in and around the first bunch compressor chicane of the FLASH (Free-electron LASer in Hamburg) linear accelerator in which two distinct systems were developed for the measurement of an electron beams' position with sub-5 μm precision over a 10 cm range. One of these two systems utilized RF techniques to measure the difference between the arrival-times of two broadband electrical pulses generated by the passage of the electron beam adjacent to a pickup antenna. The other system measured the arrival-times of the pulses from the pickup with an optical technique dependent on the delivery of laser pulses which are synchronized to the RF reference of the machine. The relative advantages and disadvantages of these two techniques are explored and compared to other available approaches to measure the same beam property, including a time-of-flight measurement with two beam arrival-time monitors and a synchrotron light monitor with two photomultiplier tubes. The electron beam position measurement is required as part of a measurement of the electron beam energy and could be used in an intra-bunch-train beam-based feedback system that would stabilize the amplitude of the accelerating field. By stabilizing the accelerating field amplitude, the arrival-time of the electron beam can be made more stable. By stabilizing the electron beam arrival-time relative to a stable reference, diagnostic, seeding, and beam-manipulation lasers can be synchronized to the beam. (orig.)

  7. The use of beam code in external radiotherapy

    International Nuclear Information System (INIS)

    Guillerminet, C.; Gschwind, R.; Makovicka, L.

    2003-01-01

    This code, in constant evolution, has several assets because it allows in one hand to better characterize the beams at the energy and angular level of accelerators at medical use; these data being accessible only by simulation and on the other hand to establish a three dimensional dose calculation fro any phantom. The limit factors are the calculation time, the size of voxels need important dimension tables for the data storage, and the compatibility between the code and the different images formats. (N.C.)

  8. A quality audit program for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, W.F.; Stovall, M. [Univ. of Texas, Houston, TX (United States)

    1993-12-31

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%.

  9. A quality audit program for external beam radiotherapy

    International Nuclear Information System (INIS)

    Hanson, W.F.; Stovall, M.

    1993-01-01

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%

  10. Manufacturing prepainted steel sheet by electron beam curing

    International Nuclear Information System (INIS)

    Oka, Joji

    1987-01-01

    Several advantages are offered by electron beam curing. A formidably hard and stain resistant paint film which is difficult to obtain by heat curing paint is developed. As a result, a unique new prepainted steel is produced. Four technologies are involved: development high-quality paint, selection of optimum electron beam processor, technology to control electron beam processing atmosphere and secondary X-ray shield technology. These technologies are described in detail. (A.J.)

  11. Highly efficient electron vortex beams generated by nanofabricated phase holograms

    Energy Technology Data Exchange (ETDEWEB)

    Grillo, Vincenzo, E-mail: vincenzo.grillo@nano.cnr.it [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); CNR-IMEM Parco Area delle Scienze 37/A, I-43124 Parma (Italy); Carlo Gazzadi, Gian [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Karimi, Ebrahim [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Department of Physics, University of Ottawa, 150 Louis Pasteur, Ottawa, Ontario K1N 6N5 (Canada); Mafakheri, Erfan [Dipartimento di Fisica Informatica e Matematica, Università di Modena e Reggio Emilia, via G Campi 213/a, I-41125 Modena (Italy); Boyd, Robert W. [Department of Physics, University of Ottawa, 150 Louis Pasteur, Ottawa, Ontario K1N 6N5 (Canada); Frabboni, Stefano [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Dipartimento di Fisica Informatica e Matematica, Università di Modena e Reggio Emilia, via G Campi 213/a, I-41125 Modena (Italy)

    2014-01-27

    We propose an improved type of holographic-plate suitable for the shaping of electron beams. The plate is fabricated by a focused ion beam on a silicon nitride membrane and introduces a controllable phase shift to the electron wavefunction. We adopted the optimal blazed-profile design for the phase hologram, which results in the generation of highly efficient (25%) electron vortex beams. This approach paves the route towards applications in nano-scale imaging and materials science.

  12. Highly efficient electron vortex beams generated by nanofabricated phase holograms

    International Nuclear Information System (INIS)

    Grillo, Vincenzo; Carlo Gazzadi, Gian; Karimi, Ebrahim; Mafakheri, Erfan; Boyd, Robert W.; Frabboni, Stefano

    2014-01-01

    We propose an improved type of holographic-plate suitable for the shaping of electron beams. The plate is fabricated by a focused ion beam on a silicon nitride membrane and introduces a controllable phase shift to the electron wavefunction. We adopted the optimal blazed-profile design for the phase hologram, which results in the generation of highly efficient (25%) electron vortex beams. This approach paves the route towards applications in nano-scale imaging and materials science

  13. Electron beam disinfection of sewage sludge

    International Nuclear Information System (INIS)

    Hashimoto, Shoji

    1992-01-01

    Electron beam treatment of dehydrated sewage sludge for safe reutilization was performed. Ranges of total bacterial counts and total coliforms in the sludge were from 1.5 x 10 8 to 1.6 x 10 9 and from 2.2 x 10 7 to 1.5 x 10 8 per wet gram, respectively. Total bacterial counts decreased about 5 log cycles after irradiating 5 kGy and irradiation with 2 kGy was enough to kill all coliforms in sewage sludge. The survival curves of total bacteria, obtained by irradiation in oxygen atmosphere, approached to that in nitrogen atmosphere with the increase of sludge thickness. No effects of dose rate and electron energy were found when the sludge layers were thin enough. Continuous disinfection of sewage sludge cake, with the maximum feed rate of 300 kg-sludge/hr, was successfully performed with a Cockcroft-Walton type electron accelerator, a sludge pump and a flat nozzle. (J.P.N.)

  14. Deterministic Nanopatterning of Diamond Using Electron Beams.

    Science.gov (United States)

    Bishop, James; Fronzi, Marco; Elbadawi, Christopher; Nikam, Vikram; Pritchard, Joshua; Fröch, Johannes E; Duong, Ngoc My Hanh; Ford, Michael J; Aharonovich, Igor; Lobo, Charlene J; Toth, Milos

    2018-03-27

    Diamond is an ideal material for a broad range of current and emerging applications in tribology, quantum photonics, high-power electronics, and sensing. However, top-down processing is very challenging due to its extreme chemical and physical properties. Gas-mediated electron beam-induced etching (EBIE) has recently emerged as a minimally invasive, facile means to dry etch and pattern diamond at the nanoscale using oxidizing precursor gases such as O 2 and H 2 O. Here we explain the roles of oxygen and hydrogen in the etch process and show that oxygen gives rise to rapid, isotropic etching, while the addition of hydrogen gives rise to anisotropic etching and the formation of topographic surface patterns. We identify the etch reaction pathways and show that the anisotropy is caused by preferential passivation of specific crystal planes. The anisotropy can be controlled by the partial pressure of hydrogen and by using a remote RF plasma source to radicalize the precursor gas. It can be used to manipulate the geometries of topographic surface patterns as well as nano- and microstructures fabricated by EBIE. Our findings constitute a comprehensive explanation of the anisotropic etch process and advance present understanding of electron-surface interactions.

  15. Simulation of an antiprotons beam applied to the radiotherapy

    International Nuclear Information System (INIS)

    Prata, Leonardo de Almeida

    2006-07-01

    Results for the interaction of a antiproton beam with constituent nuclei of the organic matter are presented. This method regards of the application of an computational algorithm to determine quantitatively the differential cross sections for the scattered particles, starting from the interaction of these antiprotons with the nuclei, what will allow in the future to draw the isodose curve for antiproton therapy, once these beams are expected to be used in cancer treatment soon. The calculation will be done through the application of the concepts of the method of intranuclear cascade, providing yield and differential cross sections of the scattered particles, present in the software MCMC. Th algorithm was developed based on Monte Carlo's method, already taking into account a validate code. The following physical quantities are presented: the yield of secondary particles, their spectral and angular distributions for these interactions. For the energy range taken into account the more important emitted particles are protons, neutrons and pions. Results shown that emitted secondary particles can modify the isodose curves, because they present high yield and energy for transverse directions. (author)

  16. Development of hollow electron beams for proton and ion collimation

    CERN Document Server

    Stancari, G.; Kuznetsov, G.; Shiltsev, V.; Still, D.A.; Valishev, A.; Vorobiev, L.G.; Assmann, R.; Kabantsev, A.

    2010-01-01

    Magnetically confined hollow electron beams for controlled halo removal in high-energy colliders such as the Tevatron or the LHC may extend traditional collimation systems beyond the intensity limits imposed by tolerable material damage. They may also improve collimation performance by suppressing loss spikes due to beam jitter and by increasing capture efficiency. A hollow electron gun was designed and built. Its performance and stability were measured at the Fermilab test stand. The gun will be installed in one of the existing Tevatron electron lenses for preliminary tests of the hollow-beam collimator concept, addressing critical issues such as alignment and instabilities of the overlapping proton and electron beams

  17. Development of hollow electron beams for proton and ion collimation

    CERN Document Server

    Stancari, G; Kuznetsov, G; Shiltsev, V; Still, D A; Valishev, A; Vorobiev, L G; Assmann, R; Kabantsev, A

    2012-01-01

    Magnetically confined hollow electron beams for controlled halo removal in high-energy colliders such as the Tevatron or the LHC may extend traditional collimation systems beyond the intensity limits imposed by tolerable material damage. They may also improve collimation performance by suppressing loss spikes due to beam jitter and by increasing capture efficiency. A hollow electron gun was designed and built. Its performance and stability were measured at the Fermilab test stand. The gun will be installed in one of the existing Tevatron electron lenses for preliminary tests of the hollow-beam collimator concept, addressing critical issues such as alignment and instabilities of the overlapping proton and electron beams.

  18. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  19. Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device

    International Nuclear Information System (INIS)

    Dirkx, M. L. P.; De Boer, J. C. J.; Heijmen, B. J. M.

    2006-01-01

    Reliable application of advanced external beam techniques for the treatment of patients with cancer, such as intensity modulated radiotherapy, requires an adequate quality assurance programme for the verification of the dose delivery. Accurate patient positioning is mandatory because of the steep dose gradients outside the tumour volume. Owing to the increased complexity of the treatment planning and delivery techniques, verification of the dose delivery before and during the actual patient treatment is equally important. For this purpose, a quality assurance programme has been established in our clinic that is primarily based on measurements with electronic portal imaging devices. To minimise systematic set-up errors, the patient positioning is measured in the first few treatment fractions and a set-up correction is applied in the subsequent ones. Before the first treatment fraction, portal dose measurements are performed for each treatment field with the electronic portal imaging device to verify that the planned fluence distribution is correctly delivered at the treatment unit. Dosimetric measurements are also performed during patient treatment to derive the actually delivered fluence maps. By combining this information with knowledge on the patient set-up, the delivered 3-D dose distribution to both the tumour and sensitive organs may be assessed. However, for the highest accuracy, exact knowledge on the (internal) patient geometry during treatment, e.g. using a cone-beam CT, is required. (authors)

  20. Electron beam melting of bearing materials

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmied, G.; Schuler, A. (Technische Univ., Vienna (Austria). Inst. fuer Allgemeine Elektrotechnik); Elsinger, G.; Koroschetz, F. (MIBA Gleitlager AG, Laakirchen (Austria)); Tschegg, E.K. (Technische Univ., Vienna (Austria). Inst. fuer Angewandte und Technische Physik)

    1990-06-01

    This paper reports on a surface treatment method for the bearing materials AlSn6 which permits the use of this material without the overlay usually required. Microstructural refinement is achieved by means of a surface melting technique using an electron beam with successive rapid solidification. Extremely fine tin precipitates are formed in the melted surface layer which lead to significantly better tribological properties of the bearing material. Tests compared the tribological properties for AlSn6 bearings treated by the surface melting technique with those of untreated bearings. Whereas all untreated bearings failed by seizure after only 2 h of testing, 30% of the tested bearings which had been surface melted survived the entire testing program without damage.

  1. Electron Cloud with Inverted Beam Screens

    CERN Document Server

    Maury Cuna, H

    2011-01-01

    We report the results of computer simulations studying the effect of wrongly oriented LHC beam screens on the local electron-cloud heat load and density. At 3.5 or 7-TeV energy and for maximum secondary emission-yield values below 1.5, with the inverted sawtooth orientation about ten times higher heat load is expected than for the standard orientation, and the wrongly oriented sawtooth chambers could lead to a local heat-load bottleneck during the process of surface conditioning at 25-ns bunch spacing. The available cooling margin can be significantly increased by correcting the sawtooth orientations at least for two dipole magnets in LHC arc cells 26 and 32 R3, in order that there be no half-cell cooling loop containing more than one inverted screen.

  2. Electron Cloud with Inverted Beam Screens

    CERN Document Server

    Maury Cuna, H; CERN. Geneva. ATS Department

    2011-01-01

    We report the results of computer simulations studying the effect of wrongly oriented LHC beam screens on the local electron-cloud heat load and density. At 3.5 or 7-TeV energy and for maximum secondary emission-yield values below 1.5, with the inverted sawtooth orientation about ten times higher heat load is expected than for the standard orientation, and the wrongly oriented sawtooth chambers could lead to a local heatload bottleneck during the process of surface conditioning at 25-ns bunch spacing. The available cooling margin can be significantly increased by correcting the sawtooth orientations at least for two dipole magnets in LHC arc cells 26 and 32 R3, in order that there be no half-cell cooling loop containing more than one inverted screen.

  3. 3D shaping of electron beams using amplitude masks

    Energy Technology Data Exchange (ETDEWEB)

    Shiloh, Roy, E-mail: royshilo@post.tau.ac.il; Arie, Ady

    2017-06-15

    Highlights: • Electron beams are shaped in 3D with examples of curves and lattices. • Computer generated holograms are manifested as binary amplitude masks. • Applications in electron-optical particle trapping, manipulation, and synthesis. • Electron beam lithography fabrication scheme explained in detail. • Measurement paradigms of 3D shaped beams are discussed. - Abstract: Shaping the electron wavefunction in three dimensions may prove to be an indispensable tool for research involving atomic-sized particle trapping, manipulation, and synthesis. We utilize computer-generated holograms to sculpt electron wavefunctions in a standard transmission electron microscope in 3D, and demonstrate the formation of electron beams exhibiting high intensity along specific trajectories as well as shaping the beam into a 3D lattice of hot-spots. The concepts presented here are similar to those used in light optics for trapping and tweezing of particles, but at atomic scale resolutions.

  4. Hollow Electron Beam Collimation for HL-LHC - Effects on the Beam Core

    Energy Technology Data Exchange (ETDEWEB)

    Fitterer, M. [Fermilab; Stancari, G. [Fermilab; Valishev, A. [Fermilab; Bruce, R. [CERN; Papotti, G [CERN; Redaelli, S. [CERN; Valentino, G. [Malta U.; Valentino, G. [CERN; Valuch, D. [CERN; Xu, C. [CERN

    2017-06-13

    Collimation with hollow electron beams is currently one of the most promising concepts for active halo control in the High Luminosity Large Hadron Collider (HL-LHC). To ensure the successful operation of the hollow beam collimator the unwanted effects on the beam core, which might arise from the operation with a pulsed electron beam, must be minimized. This paper gives a summary of the effect of hollow electron lenses on the beam core in terms of sources, provides estimates for HL-LHC and discusses the possible mitigation methods.

  5. Hollow Electron Beam Collimation for HL-LHC - Effects on the Beam Core

    CERN Document Server

    Fitterer, M; Valishev, A; Bruce, R; Papotti, G; Redaelli, S; Valentino, G; Valentino, G; Valuch, D; Xu, C

    2017-01-01

    Collimation with hollow electron beams is currently one of the most promising concepts for active halo control in the High Luminosity Large Hadron Collider (HL-LHC). To ensure the successful operation of the hollow beam collimator the unwanted effects on the beam core, which might arise from the operation with a pulsed electron beam, must be minimized. This paper gives a summary of the effect of hollow electron lenses on the beam core in terms of sources, provides estimates for HL-LHC and discusses the possible mitigation methods.

  6. Relative biological effectiveness (RBE) of proton beams in radiotherapy

    International Nuclear Information System (INIS)

    Calugaru, V.

    2011-01-01

    Treatment planning in proton therapy uses a generic value for the Relative Biological Efficiency (RBE) of 1.1 relative to 60 Co gamma-rays throughout the Spread Out Bragg Peak (SOBP). We have studied the variation of the RBE at three positions in the SOBP of the 76 and 201 MeV proton beams used for cancer treatment at the Institut Curie Proton Therapy in Orsay (ICPO) in two human tumor cell lines using clonogenic cell death and the incidence of DNA double-strand breaks (DSB) as measured by pulse-field gel electrophoresis without and with endonuclease treatment to reveal clustered lesions as endpoints.The RBE for induced cell killing by the 76 MeV beam increased with depth in the SOBP. However for the 201 MeV protons it was close to that for 137 Cs gamma-rays and did not vary significantly. The incidence of DSBs and clustered lesions was higher for protons than for 137 Cs g-rays, but did not depend on the proton energy or the position in the SOBP. In the second part of our work, we have shown using cell clones made deficient for known repair genes by stable or transient shRNA transfection, that the D-NHEJ pathway determine the response to protons. The response of DNA damages created in the distal part of the 76 MeV SOBP suggests that those damages belong to the class of DNA 'complex lesions' (LMDS). It also appears that the particle fluence is a major determinant of the outcome of treatment in the distal part of the SOBP. (author)

  7. Field size and dose distribution of electron beam

    International Nuclear Information System (INIS)

    Kang, Wee Saing

    1980-01-01

    The author concerns some relations between the field size and dose distribution of electron beams. The doses of electron beams are measured by either an ion chamber with an electrometer or by film for dosimetry. We analyzes qualitatively some relations; the energy of incident electron beams and depths of maximum dose, field sizes of electron beams and depth of maximum dose, field size and scatter factor, electron energy and scatter factor, collimator shape and scatter factor, electron energy and surface dose, field size and surface dose, field size and central axis depth dose, and field size and practical range. He meets with some results. They are that the field size of electron beam has influence on the depth of maximum dose, scatter factor, surface dose and central axis depth dose, scatter factor depends on the field size and energy of electron beam, and the shape of the collimator, and the depth of maximum dose and the surface dose depend on the energy of electron beam, but the practical range of electron beam is independent of field size

  8. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers

    International Nuclear Information System (INIS)

    Hourdakis, Constantine J.; Boziari, A.

    2008-01-01

    Background and purpose: Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002 - 2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. Materials and Methods: The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. Results: The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside ±3% and 31% outside ±5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and

  9. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.

    Science.gov (United States)

    Hourdakis, Constantine J; Boziari, A

    2008-04-01

    Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002--2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside +/-3% and 31% outside +/-5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and discussed in details. This quality audit proved to be a

  10. The Outcome of Conventional External Beam Radiotherapy for Patients with Squamous Cell Carcinoma of the Esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Young [Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2008-03-15

    The best treatment for advanced esophageal cancer is chemoradiotherapy followed by surgery. In spite of the advance of multimodality therapy, most patients with esophageal cancer are treated with radiation therapy alone. This study reports the outcome of the use of conventional external beam radiotherapy alone for the treatment of esophageal cancer. Between January 1998 and December 2005, 30 patients with squamous cell carcinoma of the esophagus were treated with external beam radiotherapy using a total dose exceeding 40 Gy. Radiotherapy was delivered with a total dose of 44-60 Gy (median dose, 57.2 Gy) over 36 {approx}115 days (median time, 45 days). Thirteen patients (43.3%) had a history of disorders such as diabetes, hypertension, tuberculosis, lye stricture, asthma, cerebral infarct, and cancers. Four patients metachronously had double primary cancers. The most common location of a tumor was the mid-thoracic portion of the esophagus (56.7%). Tumor lengths ranged from 2 cm to 11 cm, with a median length of 6 cm. For AJCC staging, stage III was the most common (63.3%). Five patients had metastases at diagnosis. The median overall survival was 8.3 months. The survival rates at 1-year and 2-years were 33.3% and 18.7%, respectively. The complete response rate 1{approx}3 months after radiotherapy was 20% (6/30) and the partial response rate was 70% (21/30). Sixteen patients (53.3%) had an improved symptom of dysphagia. Significant prognostic factors were age, tumor length, stage, degree of dysphagia at the time of diagnosis and tumor response. Cox regression analysis revealed the aim of treatment, clinical tumor response and tumor length as independent prognostic factors for overall survival. Twenty-eight patients had local failure and another four patients had metastases. Three patients were detected with double primary cancers in this analysis. A complication of esophageal stricture was observed in three patients (10%), and radiation pneumonitis occurred in two

  11. Radiotherapy

    Directory of Open Access Journals (Sweden)

    Rema Jyothirmayi

    1999-01-01

    Full Text Available Purpose. Conservative treatment in the form of limited surgery and post-operative radiotherapy is controversial in hand and foot sarcomas, both due to poor radiation tolerance of the palm and sole, and due to technical difficulties in achieving adequate margins.This paper describes the local control and survival of 41 patients with soft tissue sarcoma of the hand or foot treated with conservative surgery and radiotherapy. The acute and late toxicity of megavoltage radiotherapy to the hand and foot are described. The technical issues and details of treatment delivery are discussed. The factors influencing local control after radiotherapy are analysed.

  12. A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs.

    Science.gov (United States)

    Rodrigues, Anna; Sawkey, Daren; Yin, Fang-Fang; Wu, Qiuwen

    2015-05-01

    field sizes from 3 × 3 to 25 × 25 cm(2) were studied and results were compared to the measurement data with excellent agreement. Application of this framework can thus be used as the platform for treatment planning of dynamic electron arc radiotherapy and other advanced dynamic techniques with electron beams.

  13. Electron beam processing of carbon fibre reinforced braided composites beams

    International Nuclear Information System (INIS)

    Halasz, L.; Zsigmond, B.; Czvikovszky, T.

    2002-01-01

    Complete text of publication follows. In this paper the possibility of producing a new type carbon fiber reinforced composite is examined by applying braiding, a well-known process of textile technology. The appearance of the new Hungarian carbon fiber with excellent mechanical properties in the market enables the development of newer type carbon fiber reinforced composites in the continuously widening range of engineering applications. Advanced hollow profiles, pipes and other composite products can be manufactured in continuous operation. A new way of composite production of this kind is the manufacturing of reinforcing structure by braiding technology producing a composite with sufficient mechanical properties from this cross directional fabric-like textile structure by impregnation. This manufacturing process can complete the variety of hollow products serving the same purpose as pultrusion or filament winding. This way a profile type framework element with a hollow cross section is manufactured having favorable mechanical properties. Owing to its small mass and high specific strength this product can be applied in dynamically loaded structures e.g. in the automotive industry. For crosslinking of the matrix the method of high-speed electron beam curing has been examined in order to reach continuous operation. The field of use and application of carbon fiber braided structures has a great chance especially in machine engineering and in the automotive industry. The main reason for this is that braiding processes are capable of producing structures having good mechanical properties at a low processing price. The mass of the composite load-bearing structure produced this way is one fifth of the steel product having similar geometry, and its specific mechanical properties are nearly as good as that of the most commonly applied semiproduct and structural component, the welded steel profile

  14. Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays.

    Science.gov (United States)

    Zygmanski, Piotr; Sajo, Erno

    2016-01-01

    We review radiation transport and clinical beam modelling for gold nanoparticle dose-enhanced radiotherapy using X-rays. We focus on the nanoscale radiation transport and its relation to macroscopic dosimetry for monoenergetic and clinical beams. Among other aspects, we discuss Monte Carlo and deterministic methods and their applications to predicting dose enhancement using various metrics.

  15. Accuracy of image-guided radiotherapy of prostate cancer based on the BeamCath urethral catheter technique

    DEFF Research Database (Denmark)

    Poulsen, Per Rugaard; Fokdal, Lars; Petersen, Jørgen B.B.

    2007-01-01

    BACKGROUND AND PURPOSE: To examine the accuracy of the BeamCath urethral catheter technique for prostate localization during radiotherapy. MATERIALS AND METHODS: Sixty-four patients were CT scanned twice with the BeamCath catheter, and once without the catheter. The catheter contains radiopaque...

  16. Electron-beam and microwave treatment of some microbial strains

    International Nuclear Information System (INIS)

    Martin, D.; Ferdes, O.S.; Minea, R.; Tirlea, A.; Badea, M.; Plamadeala, S.; Ferdes, M.

    1998-01-01

    The experimental results concerning the combined effects of microwaves and accelerated electron beams on various microbial strains such as E. coli, Salmonella sp. and Monascus purpureus are presented. A special designed microwave applicator with a 2.45 GHz frequency CW magnetron of 850 maximum output power and with associate electronics that allow to control the microwave power, the current intensity, and the exposure time was used. The electron-beam irradiation was performed at different irradiation doses and at a dose rate of 1.5 - 2.0 kGy/min by using a linac at a mean electron energy about 6 MeV, mean bean current of 10 μA, pulse period of 3.5 μs and repetition frequency 100 Hz. The experiments were carried out in 5 variants: microwave treatment; electron-beam irradiation; microwaves followed by electron beam; electrons followed by microwaves; and simultaneous application of microwaves and electron beam. The microbiocidal effect was found to be enhanced by additional use of microwave energy to electron beam irradiation. Enhancement of inactivation rate is only remarkable for the microwave treatment or simultaneous electron beam and microwave irradiation at a temperature above the critical value at which microorganisms begin to perish by heat. Simultaneous irradiation with electron beam and microwaves results in a reduction of temperature and time as well as in the decrease of the upper limit of required electron beam absorbed dose for an assumed microbiological quality parameter. The results obtained indicate the occurrence of a synergistic effect of the two physical fields on a non-thermal basis. Hence, combined microwave-electron beam treatment may be applied as an effective method to reduce microbial load

  17. A Preliminary Design Of Application Of Wireless Identification And Sensing Platform On External Beam Radiotherapy

    Science.gov (United States)

    Heranudin; Bakhri, S.

    2018-02-01

    A linear accelerator (linac) is widely used as a means of radiotherapy by focusing high-energy photons in the targeted tumor of patient. Incorrectness of the shooting can lead normal tissue surrounding the tumor received unnecessary radiation and become damaged cells. A method is required to minimize the incorrectness that mostly caused by movement of the patient during radiotherapy process. In this paper, the Wireless Identification and Sensing Platform (WISP) architecture was employed to monitor in real time the movement of the patient’s body during radiotherapy process. In general, the WISP is a wearable sensors device that can transmit measurement data wirelessly. In this design, the measurement devices consist of an accelerometer, a barometer and an ionizing radiation sensor. If any changes in the body position which resulted in incorrectness of the shooting, the accelerometer and the barometer will trigger a warning to the linac operator. In addition, the radiation sensor in the WISP will detect unwanted radiation and that can endanger the patient. A wireless feature in this device can ease in implementation. Initial analyses have been performed and showed that the WISP is feasible to be applied on external beam radiotherapy.

  18. Fractionated external beam radiotherapy of skull base metastases with cranial nerve involvement

    Energy Technology Data Exchange (ETDEWEB)

    Droege, L.H.; Hinsche, T.; Hess, C.F.; Wolff, H.A. [University Hospital of Goettingen, Department of Radiotherapy and Radiation Oncology, Goettingen (Germany); Canis, M. [University of Goettingen, Department of Otorhinolaryngology, Head and Neck Surgery, Goettingen (Germany); Alt-Epping, B. [University of Goettingen, Department of Palliative Medicine, Goettingen (Germany)

    2014-02-15

    Skull base metastases frequently appear in a late stage of various tumor entities and cause pain and neurological disorders which strongly impair patient quality of life. This study retrospectively analyzed fractionated external beam radiotherapy (EBRT) as a palliative treatment approach with special respect to neurological outcome, feasibility and acute toxicity. A total of 30 patients with skull base metastases and cranial nerve disorders underwent EBRT with a mean total dose of 31.6 Gy. Neurological status was assessed before radiotherapy, during radiotherapy and 2 weeks afterwards categorizing orbital, parasellar, middle fossa, jugular foramen and occipital condyle involvement and associated clinical syndromes. Neurological outcome was scored as persistence of symptoms, partial response, good response and complete remission. Treatment-related toxicity and overall survival were assessed. Before EBRT 37 skull base involvement syndromes were determined with 4 patients showing more than 1 syndrome. Of the patients 81.1 % responded to radiotherapy with 10.8 % in complete remission, 48.6 % with good response and 21.6 % with partial response. Grade 1 toxicity of the skin occurred in two patients and grade 1 hematological toxicity in 1 patient under concurrent chemoradiotherapy. Median overall survival was 3.9 months with a median follow-up of 45 months. The use of EBRT for skull base metastases with symptomatic involvement of cranial nerves is marked by good therapeutic success in terms of neurological outcome, high feasibility and low toxicity rates. These findings underline EBRT as the standard therapeutic approach in the palliative setting. (orig.)

  19. Fractionated external beam radiotherapy of skull base metastases with cranial nerve involvement

    International Nuclear Information System (INIS)

    Droege, L.H.; Hinsche, T.; Hess, C.F.; Wolff, H.A.; Canis, M.; Alt-Epping, B.

    2014-01-01

    Skull base metastases frequently appear in a late stage of various tumor entities and cause pain and neurological disorders which strongly impair patient quality of life. This study retrospectively analyzed fractionated external beam radiotherapy (EBRT) as a palliative treatment approach with special respect to neurological outcome, feasibility and acute toxicity. A total of 30 patients with skull base metastases and cranial nerve disorders underwent EBRT with a mean total dose of 31.6 Gy. Neurological status was assessed before radiotherapy, during radiotherapy and 2 weeks afterwards categorizing orbital, parasellar, middle fossa, jugular foramen and occipital condyle involvement and associated clinical syndromes. Neurological outcome was scored as persistence of symptoms, partial response, good response and complete remission. Treatment-related toxicity and overall survival were assessed. Before EBRT 37 skull base involvement syndromes were determined with 4 patients showing more than 1 syndrome. Of the patients 81.1 % responded to radiotherapy with 10.8 % in complete remission, 48.6 % with good response and 21.6 % with partial response. Grade 1 toxicity of the skin occurred in two patients and grade 1 hematological toxicity in 1 patient under concurrent chemoradiotherapy. Median overall survival was 3.9 months with a median follow-up of 45 months. The use of EBRT for skull base metastases with symptomatic involvement of cranial nerves is marked by good therapeutic success in terms of neurological outcome, high feasibility and low toxicity rates. These findings underline EBRT as the standard therapeutic approach in the palliative setting. (orig.)

  20. Measurement of the absorbed dose in the very small size photon beams used in stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Derreumaux, S.; Huet, C.; Robbes, I.; Trompier, F.; Boisserie, G.; Brunet, G.; Buchheit, I.; Sarrazin, T.; Chea, M.

    2008-01-01

    After the radiotherapy accident in Toulouse, the French authority of nuclear safety and the French agency of health products safety have asked the IR.S.N. to establish, together with experts from the French society of medical physics and the French society of radiotherapy and oncology, a national protocol on dose calibration for the very small beams used in stereotactic radiotherapy. The research and reflexions of the working group 'GT minifaisceaux ' set up by the I.R.S.N. are presented in this final report. A review of the international literature has been performed. A national survey has been done to know the present practices in the dosimetry of small fields. A campaign of measurements of the data needed to characterize the small beams for the different stereotactic systems has started, using different types of detectors acquired by the I.R.S.N.. In this report are presented a deep synthesis on the problems related to the dosimetry of small fields, the results of the national survey, the first results of the campaign of measurements and the recommendations of the GT. (authors)

  1. Commercializing ALURTRONs electron beam irradiation services

    International Nuclear Information System (INIS)

    Siti Aiasah Hashim; Mohd Sidek Othman; Shari Jahar; Sarada Idris; Naurah Mohd Isa; Muhamad Zahidee Taat

    2010-01-01

    ALURTRON has been the nation's sole electron irradiation service provider for research sectors. The main irradiation is done by utilising the EPS 3000 Cockcroft-Walton type 3.0 MeV, 90 k Watts electron beam machine (EBM). With more than 15 years experience in the operation and maintenance of the EPS, the challenge is now to commercialize the service at a larger and profitable scale. Medical products sterilization at commercial level has been ruled out since the energy is insufficient to penetrate dense and non-homogenous items. Recently, the demand for irradiation of wire and heat shrinkable tubes is showing bigger commercial potential. Therefore, prudent planning considerations need to be taken to ensure profitable return to the agency. Calculations were made to estimate ALURTRON service capacity, based on the existing EBM and its auxiliary systems. Details of the calculation including all the variables are presented. Results indicated that Alurtron should be able to process a minimum of 1000 km of small wires per month, running at 150 m/ min, working in two shifts, 5 days a week. The projected revenue is dependent on the charges imposed on the basis of total length delivered. (author)

  2. The operational procedure of an electron beam accelerator

    International Nuclear Information System (INIS)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-01

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator

  3. Planar Heating Element Adjusted by Electron Beam Micromachining

    Czech Academy of Sciences Publication Activity Database

    Dupák, Libor; Dupák, Jan

    2009-01-01

    Roč. 44, 5-6 (2009), s. 82-84 ISSN 0861-4717 Institutional research plan: CEZ:AV0Z20650511 Keywords : electron beam machining * heating element Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  4. Calculation of uncertainties in the protocol of dosimetry for Co 60 beams in Radiotherapy

    International Nuclear Information System (INIS)

    Velazquez M, S.; Carrera M, F.; Sanchez S, J.

    1998-01-01

    The objective in this work is to show how the uncertainty is possible to know in the determination of the absorbed dose in Co 60 photon beams and to establish in a rational form, tolerance levels for this. It is took as base the spanish protocol of dosimetry in Radiotherapy. We have been centered in a Co 60 beam. We utilized the statistical theory of little samples. We allowed to suggest a new approach about the treatment of the tolerance levels and the uncertainty of the measurement. After two years of experience in the practical hospitable application we have gotten to put around 1 % uncertainty in the absolute dosimetry of the Co 60 beam. The presented protocol allows to execute the accuracy requirements in the determination of absorbed doses. (Author)

  5. Initial clinical outcomes of proton beam radiotherapy for hepatocellular carcinoma.

    Science.gov (United States)

    Yu, Jeong Il; Yoo, Gyu Sang; Cho, Sungkoo; Jung, Sang Hoon; Han, Youngyih; Park, Seyjoon; Lee, Boram; Kang, Wonseok; Sinn, Dong Hyun; Paik, Yong-Han; Gwak, Geum-Youn; Choi, Moon Seok; Lee, Joon Hyeok; Koh, Kwang Cheol; Paik, Seung Woon; Park, Hee Chul

    2018-03-01

    This study aimed to evaluate the initial outcomes of proton beam therapy (PBT) for hepatocellular carcinoma (HCC) in terms of tumor response and safety. HCC patients who were not indicated for standard curative local modalities and who were treated with PBT at Samsung Medical Center from January 2016 to February 2017 were enrolled. Toxicity was scored using the Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Tumor response was evaluated using modified Response Evaluation Criteria in Solid Tumors (mRECIST). A total of 101 HCC patients treated with PBT were included. Patients were treated with an equivalent dose of 62-92 GyE 10 . Liver function status was not significantly affected after PBT. Greater than 80% of patients had Child-Pugh class A and albumin-bilirubin (ALBI) grade 1 up to 3-months after PBT. Of 78 patients followed for three months after PBT, infield complete and partial responses were achieved in 54 (69.2%) and 14 (17.9%) patients, respectively. PBT treatment of HCC patients showed a favorable infield complete response rate of 69.2% with acceptable acute toxicity. An additional follow-up study of these patients will be conducted.

  6. Design of 6 MeV X-band electron linac for dual-head gantry radiotherapy system

    Science.gov (United States)

    Shin, Seung-wook; Lee, Seung-Hyun; Lee, Jong-Chul; Kim, Huisu; Ha, Donghyup; Ghergherehchi, Mitra; Chai, Jongseo; Lee, Byung-no; Chae, Moonsik

    2017-12-01

    A compact 6 MeV electron linac is being developed at Sungkyunkwan University, in collaboration with the Korea atomic energy research institute (KAERI). The linac will be used as an X-ray source for a dual-head gantry radiotherapy system. X-band technology has been employed to satisfy the size requirement of the dual-head gantry radiotherapy machine. Among the several options available, we selected a pi/2-mode, standing-wave, side-coupled cavity. This choice of radiofrequency (RF) cavity design is intended to enhance the shunt impedance of each cavity in the linac. An optimum structure of the RF cavity with a high-performance design was determined by applying a genetic algorithm during the optimization procedure. This paper describes the detailed design process for a single normal RF cavity and the entire structure, including the RF power coupler and coupling cavity, as well as the beam dynamics results.

  7. Transport of a relativistic electron beam through hydrogen gas

    International Nuclear Information System (INIS)

    Haan, P. de.

    1981-01-01

    In this thesis the author describes the transport properties of an electron beam through vacuum and through hydrogen gas with pressure ranging from 25 to 1000 Pa. Maximum beam energy and current are 0.8 MeV and 6 kA, respectively. The pulse length is around 150 ns. A description is given of the experimental device. Also the diagnostics for probing the beam and the plasma, produced by the beam, are discussed, as well as the data acquisition system. The interaction between the beam and hydrogen gas with a pressure around 200 Pa is considered. A plasma with density around 10 19 m -3 is produced within a few nanoseconds. Measurements yield the atomic hydrogen temperature, electron density, beam energy loss, and induced plasma current and these are compared with the results of a model combining gas ionization and dissociation, and turbulent plasma heating. The angular distribution of the beam electrons about the magnetic field axis is discussed. (Auth.)

  8. Effect of electron beam on in vitro cultured orchid organs

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jaihyunk; Bae, Seho; Bae, Changhyu [Sunchon National Univ., Suncheon (Korea, Republic of); Kang, Hyun Suk; Lee, Byung Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-07-01

    Ionizing radiations have been effective mutagen sources to overcome the limitation of the useful genetic resources in natural environment. The study was conducted to investigate an effect of electron beam on organogenesis, growth patterns and genetic variation in the irradiated orchid organs. The in utero cultured rhizomes of orchids were irradiated with the electron beam in the dose range of 15Gy to 2240Gy under the condition of various beam energy and beam current. Significant decreases in survival, growth and organogenesis were observed by increase of intensity of electron beam irradiation. The irradiation intensity of lethal dose 50 of the in utero cultured orchid was estimated as approximately 500Gy to 1000Gy under 10MeV/n, and 1000Gy was optimal for growth and organogenesis of the cultures under 10MeV/n with 0.05mA treatment, and 15Gy {approx} 48Gy under 2MeV/n and 0.5mA electron beam condition. RAPD and ISSR analyses for the electron beam irradiated organs were performed to analyze genetic variation under the electron beam condition. Both of RAPD and ISSR analyses showed higher polymorphic rate in the electron-beam irradiated C. gangrene and C. Kaner.

  9. Surface dynamics using pulsed electron beams

    Science.gov (United States)

    Chan, Ally S. Y.; Jones, Robert G.

    2000-04-01

    Line of sight time of flight has been used to measure the translational energy of ethene formed by dissociative electron attachment of adsorbed dihalocarbons (XCH 2CH 2Y) on Cu(111) at 100 K. A pulsed electron beam was used to generate low energy secondary electrons at the surface, which were the active agents in initiating the decomposition, XCH 2CH 2Y(ads)+e -→XCH 2CH 2rad (ads)+Y(chem)+e -, XCH 2CH 2rad (ads)→C 2H 4(g)+X(chem). For 1,2-dichloroethane (DCE) adsorbed with a spacer layer of chemisorbed chlorine between it and the Cu(111)surface, the TOF data could be fitted using three Maxwell distributions with fast (960 K), slow (180 K) and diffusion ('20 K') components. For a single monolayer of DCE adsorbed directly on the clean Cu(111) surface the fast (1230 K) and slow (225 K) components increased in temperature, indicating that the copper surface was affecting the reaction. For 1-bromo-2-chloroethane the results were the same, consistent with both molecules dissociating via a common intermediate, ClC 2H 4rad (ads). For 1,2-dibromoethane the intermediate is different, BrC 2H 4rad , and decomposition of a monolayer of this molecule on clean Cu(111) exhibited fast (1850 K) and slow (270 K) components, both higher than the corresponding temperatures for DCE. The dynamics of these reactions and the origin of the two Maxwell distributions are discussed in terms of the energy available within the radical, and from the formation of the chemisorbed halogen when the radical dissociates.

  10. Delivery validation of an automated modulated electron radiotherapy plan

    International Nuclear Information System (INIS)

    Connell, T.; Papaconstadopoulos, P.; Alexander, A.; Serban, M.; Devic, S.; Seuntjens, J.

    2014-01-01

    Purpose: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. Methods: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. Results: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3  mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. Conclusions: Results of the authors’ study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies

  11. A beam profile monitor for small electron beams

    International Nuclear Information System (INIS)

    Norem, J.

    1991-01-01

    Measurement of beam properties at the foci of high energy linacs is difficult due to the small size of the waists in proposed and existing accelerators (1 nm - 2 μ). This paper considers the use of bremsstrahlung radiation from thin foils to measure the size and phase space density these beams using nonimaging optics. The components of the system are described, and the ultimate resolution, evaluated theoretically for the case of the Final Focus Test Beam at Stanford Linear Accelerator Center, is a few nm. 13 refs., 4 figs. 1 tab

  12. Measurements on wave propagation characteristics of spiraling electron beams

    Science.gov (United States)

    Singh, A.; Getty, W. D.

    1976-01-01

    Dispersion characteristics of cyclotron-harmonic waves propagating on a neutralized spiraling electron beam immersed in a uniform axial magnetic field are studied experimentally. The experimental setup consisted of a vacuum system, an electron-gun corkscrew assembly which produces a 110-eV beam with the desired delta-function velocity distribution, a measurement region where a microwave signal is injected onto the beam to measure wavelengths, and a velocity analyzer for measuring the axial electron velocity. Results of wavelength measurements made at beam currents of 0.15, 1.0, and 2.0 mA are compared with calculated values, and undesirable effects produced by increasing the beam current are discussed. It is concluded that a suitable electron beam for studies of cyclotron-harmonic waves can be generated by the corkscrew device.

  13. Optical circular deflector with attosecond resolution for ultrashort electron beam

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2017-05-01

    Full Text Available A novel method using high-power laser as a circular deflector is proposed for the measurement of femtosecond (fs and sub-fs electron beam. In the scheme, the electron beam interacts with a laser pulse operating in a radially polarized doughnut mode (TEM_{01^{*}} in a helical undulator, generating angular kicks along the beam in two directions at the same time. The phase difference between the two angular kicks makes the beam form a ring after a propagation section with appropriate phase advance, which can reveal the current profile of the electron beam. Detailed theoretical analysis of the method and numerical results with reasonable parameters are both presented. It is shown that the temporal resolution can reach up to ∼100 attosecond, which is a significant improvement for the diagnostics of ultrashort electron beam.

  14. Landau Damping of Beam Instabilities by Electron Lenses

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V. [Fermilab; Alexahin, Yuri; Burov, A. [Fermilab; Valishev, A. [Fermilab

    2017-06-26

    Modern and future particle accelerators employ increasingly higher intensity and brighter beams of charged particles and become operationally limited by coherent beam instabilities. Usual methods to control the instabilities, such as octupole magnets, beam feedback dampers and use of chromatic effects, become less effective and insufficient. We show that, in contrast, Lorentz forces of a low-energy, a magnetically stabilized electron beam, or "electron lens", easily introduces transverse nonlinear focusing sufficient for Landau damping of transverse beam instabilities in accelerators. It is also important that, unlike other nonlinear elements, the electron lens provides the frequency spread mainly at the beam core, thus allowing much higher frequency spread without lifetime degradation. For the parameters of the Future Circular Collider, a single conventional electron lens a few meters long would provide stabilization superior to tens of thousands of superconducting octupole magnets.

  15. Beam heating in solar flares - Electrons or protons?

    International Nuclear Information System (INIS)

    Brown, J.C.; Karlicky, M.; Mackinnon, A.L.; Van Den Oord, G.H.J.

    1990-01-01

    The current status of electron and proton beam models as candidates for the impulsive phase heating of solar flares is discussed in relation to observational constants and theoretical difficulties. It is concluded that, while the electron beam model for flare heating still faces theoretical and observational problems, the problems faced by low and high energy proton beam models are no less serious, and there are facets of proton models which have not yet been studied. At the present, the electron beam model remains the most viable and best developed of heating model candidates. 58 refs

  16. KrF laser pumping by electron beam discharge

    International Nuclear Information System (INIS)

    Bonnet, Jean; Fournier, Gerard; Pigache, Daniel

    1981-01-01

    Homogeneous ionization with an electron beam has permitted discharge pumping of a KrF laser with a discharge-energy/beam-energy ratio greater than 5. This high value is obtained to the detriment of an energy density and an efficiency which are about half the best values obtained under other conditions. This new result does not really modify a recent conclusion indicating that an electron beam controlled discharge has no significant advantage over a pure electron beam as regards pumping high energy KrF lasers at high repetition rate [fr

  17. Beam angle selection for intensity-modulated radiotherapy (IMRT) treatment of unresectable pancreatic cancer: are noncoplanar beam angles necessary?

    Science.gov (United States)

    Chang, D S; Bartlett, G K; Das, I J; Cardenes, H R

    2013-09-01

    External beam radiation therapy with concurrent chemotherapy (CRT) is widely used for the treatment of unresectable pancreatic cancer. Noncoplanar (NCP) 3D conformal radiotherapy (3DCRT) and coplanar (CP) IMRT have been reported to lower the radiation dose to organs at risk (OARs). The purpose of this article is to examine the utility of noncoplanar beam angles in IMRT for the management of pancreatic cancer. Sixteen patients who were treated with CRT for unresectable adenocarcinoma of the pancreatic head or neck were re-planned using CP and NCP beams in 3DCRT and IMRT with the Varian Eclipse treatment planning system. Compared to CP IMRT, NCP IMRT had similar target coverage with slightly increased maximum point dose, 5,799 versus 5,775 cGy (p = 0.008). NCP IMRT resulted in lower mean kidney dose, 787 versus 1,210 cGy (p kidney dose, but did not improve other dose-volume criteria. The use of NCP beam angles is preferred only in patients with risk factors for treatment-related kidney dysfunction.

  18. Supine proton beam craniospinal radiotherapy using a novel tabletop adapter

    Energy Technology Data Exchange (ETDEWEB)

    Buchsbaum, Jeffrey C., E-mail: jbuchsba@iupui.edu [IU Health Proton Therapy Center, Bloomington, IN (United States); Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States); Department of Pediatrics, Indiana University School of Medicine, Indianapolis, IN (United States); Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, IN (United States); Besemer, Abby; Simmons, Joseph; Hoene, Ted; Simoneaux, Victor; Sandefur, Amy [IU Health Proton Therapy Center, Bloomington, IN (United States); Wolanski, Mark; Li, Zhao; Cheng, Chee-Wei [IU Health Proton Therapy Center, Bloomington, IN (United States); Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)

    2013-04-01

    To develop a device that allows supine craniospinal proton and photon therapy to the vast majority of proton and photon facilities currently experiencing limitations as a result of couch design issues. Plywood and carbon fiber were used for the development of a prototype unit. Once this was found to be satisfactory after all design issues were addressed, computer-assisted design (CAD) was used and carbon fiber tables were built to our specifications at a local manufacturer of military and racing car carbon fiber parts. Clinic-driven design was done using real-time team discussion for a prototype design. A local machinist was able to construct a prototype unit for us in <2 weeks after the start of our project. Once the prototype had been used successfully for several months and all development issues were addressed, a custom carbon fiber design was developed in coordination with a carbon fiber manufacturer in partnership. CAD methods were used to design the units to allow oblique fields from head to thigh on patients up to 200 cm in height. Two custom-designed carbon fiber craniospinal tabletop designs now exist: one long and one short. Four are in successful use in our facility. Their weight tolerance is greater than that of our robot table joint (164 kg). The long unit allows for working with taller patients and can be converted into a short unit as needed. An affordable, practical means of doing supine craniospinal therapy with protons or photons can be used in most locations via the use of these devices. This is important because proton therapy provides a much lower integral dose than all other therapy methods for these patients and the supine position is easier for patients to tolerate and for anesthesia delivery. These units have been successfully used for adult and pediatric supine craniospinal therapy, proton therapy using oblique beams to the low pelvis, treatment of various spine tumors, and breast-sparing Hodgkin's therapy.

  19. Differentiated Thyroid Cancer with Extrathyroidal Extension: Prognosis and the Role of External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Michael A. Sia

    2010-01-01

    Full Text Available A study was performed to identify variables that affected cause-specific survival (CSS and local relapse-free rate (LRFR in patients with differentiated thyroid cancer (DTC and extrathyroid extension (ETE and to examine the role of external beam radiotherapy (XRT. Prognostic factors were similar to those found in studies of all patients with DTC. In patients with postoperative gross residual disease treated with radiotherapy, 10-year CSS and LRFR were 48% and 90%. For patients with no residual or microscopic disease, 10-year CSS and LRFR were 92% and 93%. In patients older than 60 years with T3 ETE but no gross residual disease postoperatively there was an improved LRFR at 5 years of 96%, compared to 87.5% without XRT (P=.02. Patients with gross ETE benefit from XRT and there may be a potential benefit in reducing locoregional failure in patients over 60 years with minimal extrathyroidal extension (T3.

  20. Electron-beam-fusion progress report, January--June 1976

    International Nuclear Information System (INIS)

    1976-10-01

    Research progress is reported for the following areas: (1) Proto I, (2) Proto II, (3) EBFA, (4) power flow, (5) contract progress reports, (6) progress in the Sandia program, (7) repetitively operated pulse generator development, (8) electron beam power from inductive storage, (9) fusion target design, (10) beam physics research, (11) power flow, (12) heavy ion fusion, (13) particle beam source development, (14) beam target interaction and target response studies, (15) diagnostic development, and (16) hybrid systems

  1. The CNAO dose delivery system for modulated scanning ion beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Giordanengo, S.; Marchetto, F. [Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125 (Italy); Garella, M. A.; Donetti, M. [Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125, Italy and Centro Nazionale Adroterapia Oncologica, Pavia 27100 (Italy); Bourhaleb, F.; Monaco, V.; Hosseini, M. A.; Peroni, C.; Sacchi, R.; Cirio, R. [Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125, Italy and Physics Department, University of Torino, Torino 10125 (Italy); Ciocca, M.; Mirandola, A. [Centro Nazionale Adroterapia Oncologica, Pavia 27100 (Italy)

    2015-01-15

    Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing

  2. Comparison of High Resolution Negative Electron Beam Resists

    DEFF Research Database (Denmark)

    Olsen, Brian Bilenberg; Schøler, Mikkel; Shi, Peixiong

    2006-01-01

    Four high resolution negative electron beam resists are compared: TEBN-1 from Tokuyama Corp. Japan, ma-N 2401XP and mr-L 6000AXP from microresist technology GmbH Germany, and SU-8 2000 series from MicroChem Corp., USA. Narrow linewidth high density patterns are defined by 100 kV electron beam...

  3. Method of determining the position of an irradiated electron beam

    International Nuclear Information System (INIS)

    Fukuda, Wataru.

    1967-01-01

    The present invention relates to the method of determining the position of a radiated electron beam, in particular, the method of detecting the position of a p-n junction by a novel method when irradiating the electron beam on to the semi-conductor wafer, controlling the position of the electron beam from said junction. When the electron beam is irradiated on to the semi-conductor wafer which possesses the p-n junction, the position of the p-n junction may be ascertained to determine the position of the irradiated electron beam by detecting the electromotive force resulting from said p-n junction with a metal disposed in the proximity of but without mechanical contact with said semi-conductor wafer. Furthermore, as far as a semi-conductor wafer having at least one p-n junction is concerned, the present invention allows said p-n junction to be used to determine the position of an irradiated electron beam. Thus, according to the present invention, the electromotive force of the electron beam resulting from the p-n junction may easily be detected by electrostatic coupling, enabling the position of the irradiated electron beam to be accurately determined. (Masui, R.)

  4. Metastable atom probe for measuring electron beam density profiles

    Science.gov (United States)

    Lockhart, J. M.; Zorn, J. C.

    1972-01-01

    Metastable atom probe was developed for measuring current density in electron beam as function of two arbitrary coordinates, with spatial resolution better than 0.5 mm. Probe shows effects of space charge, magnetic fields, and other factors which influence electron current density, but operates with such low beam densities that introduced perturbation is very small.

  5. Application of electron beam technology in improving sewage water ...

    African Journals Online (AJOL)

    The use of electron beam to disinfect sewage water is gaining importance. The current problem on environmental health in relation to water pollution insists for the safe disposal of sewage water. In general, sewage water comprises of heterogeneous organic based chemicals as well as pathogens. EB (electron beam) ...

  6. Treatment planning for heavy ion radiotherapy: physical beam model and dose optimization

    International Nuclear Information System (INIS)

    Kraemer, M.; Haberer, T.; Kraft, G.; Schardt, D.; Weber, U.

    2000-09-01

    We describe a novel code system, TRiP, dedicated to the planning of radiotherapy with energetic ions, in particular 12 C. The software is designed to cooperate with three-dimensional active dose shaping devices like the GSI raster scan system. This unique beam delivery system allows to select any combination from a list of 253 individual beam energies, 7 different beam spot sizes and 15 intensity levels. The software includes a beam model adapted to and verified for carbon ions. Inverse planning techniques are implemented in order to obtain a uniform target dose distribution from clinical input data, i.e. CT images and patient contours. This implies the automatic generation of intensity modulated fields of heavy ions with as many as 40000 raster points, where each point corresponds to a specific beam position, energy and particle fluence. This set of data is directly passed to the beam delivery and control system. The treatment planning code is in clinical use since the start of the GSI pilot project in December 1997. To this end 48 patients have been successfully planned and treated. (orig.)

  7. Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization

    Science.gov (United States)

    Krämer, M.; Jäkel, O.; Haberer, T.; Kraft, G.; Schardt, D.; Weber, U.

    2000-11-01

    We describe a novel code system, TRiP, dedicated to the planning of radiotherapy with energetic ions, in particular 12C. The software is designed to cooperate with three-dimensional active dose shaping devices like the GSI raster scan system. This unique beam delivery system allows us to select any combination from a list of 253 individual beam energies, 7 different beam spot sizes and 15 intensity levels. The software includes a beam model adapted to and verified for carbon ions. Inverse planning techniques are implemented in order to obtain a uniform target dose distribution from clinical input data, i.e. CT images and patient contours. This implies the automatic generation of intensity modulated fields of heavy ions with as many as 40 000 raster points, where each point corresponds to a specific beam position, energy and particle fluence. This set of data is directly passed to the beam delivery and control system. The treatment planning code has been in clinical use since the start of the GSI pilot project in December 1997. Forty-eight patients have been successfully planned and treated.

  8. Radiotherapy physics

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Collier, J.M.; Lyman, J.T.; Pitluck, S.

    1982-01-01

    The Radiotherapy Physics Group works on the physical and biophysical aspects of charged particle radiotherapy. Our activities include the development of isosurvival beams (beams of uniform biological effect), computerized treatment planning development for charged particle radiotherapy, design of compensation to shape dose distributions, and development of dosimetry techniques to verify planned irradiations in both phantoms and patients

  9. Measurement of centroid trajectory of Dragon-I electron beam

    International Nuclear Information System (INIS)

    Jiang Xiaoguo; Wang Yuan; Zhang Wenwei; Zhang Kaizhi; Li Jing; Li Chenggang; Yang Guojun

    2005-01-01

    The control of the electron beam in an intense current linear induction accelerator (LIA) is very important. The center position of the electron beam and the beam profile are two important parameters which should be measured accurately. The setup of a time-resolved measurement system and a data processing method for determining the beam center position are introduced for the purpose of obtaining Dragon-I electron beam trajectory including beam profile. The actual results show that the centroid position error can be controlled in one to two pixels. the time-resolved beam centroid trajectory of Dragon-I (18.5 MeV, 2 kA, 90 ns) is obtained recently in 10 ns interval, 3 ns exposure time with a multi-frame gated camera. The results show that the screw movement of the electron beam is mainly limited in an area with a radius of 0.5 mm and the time-resolved diameters of the beam are 8.4 mm, 8.8 mm, 8.5 mm, 9.3 mm and 7.6 mm. These results have provided a very important support to several research areas such as beam trajectory tuning and beam transmission. (authors)

  10. Postmastectomy electron-beam chest-wall irradiation in women with breast cancer

    International Nuclear Information System (INIS)

    Gez, Eliahu; Ashaf, Nurit; Bar-Deroma, Rachel; Rosenblatt, Edward; Kuten, Abraham

    2004-01-01

    Purpose: This retrospective study evaluates the results of postmastectomy electron-beam chest-wall irradiation in patients with breast cancer. Methods and materials: From 1980 to 1994, 144 women with localized breast cancer received postmastectomy radiotherapy. The chest wall was irradiated by electron beam, 6 to 12 MeV energy, depending on wall thickness, 2.0 Gy daily, 5 times/week for total dose of 50 Gy. Forty-one patients received 16-Gy boosts to the mastectomy scar. In addition, the supraclavicular and axilla areas were irradiated by anterior field with 6-MV photon beam. Results: Median follow-up was 84 months. Fifteen patients (10%) had local-regional recurrence (LRR) and 57 patients (40%) had systemic relapse (SR). Median time from mastectomy to LRR was 20 months and median time to SR was 33 months. Axillary lymph nodes status influenced both LRR and SR. LRR rate was 0% in N0 and 12% in N1 disease; SR rate was 14% in N0 and 45% in N1 disease. Disease-free and overall survival was 58% and 67% in 10 years and 50% and 55% in 20 years, respectively. No cardiac toxicity was related to left chest-wall irradiation. Conclusion: Postmastectomy electron-beam chest-wall irradiation is as effective as photon-beam irradiation in breast cancer

  11. External beam radiotherapy for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Sagerman, R.H.; Chun, H.C.; King, G.A.; Chung, C.T.; Dalal, P.S.

    1989-01-01

    Five hundred nineteen patients with prostate cancer were seen in the Radiation Oncology Division of the State University of New York (SUNY) Health Science Center, Syracuse, New York, between 1969 and 1981. The results for the 239 patients treated with radical intent are reported here. All patients received 60 to 70 Gy to the prostate with megavoltage beam irradiation; 142 with a small field (10 X 10 cm) 360 degrees rotational technique for Stage A, B, or C disease and 69 with a four-field pelvic brick technique (followed by a boost to the prostate) for Stage A through C and D1 disease. Twenty-eight patients were treated postoperatively for residual disease after radical prostatectomy or for recurrent tumor. The minimum follow-up time was 5 years. Actuarial 5-year and 7-year survival rates for Stage A (n = 34), B (n = 100), C (n = 63), and D1 (n = 14) were 91% and 76%, 86% and 75%, 67% and 40%, and 46% and 36%, respectively. The corresponding 5-year and 7-year relapse-free survival rates were 72% and 65%, 77% and 60%, 46% and 28%, and 38% and 25%. The local tumor control rates at 5 years were 91%, 85%, 77%, and 62% for Stage A, B, C, and D1, respectively. In our experience, there was no significant difference in relapse-free survival rates for patients who underwent transurethral resection (TURP) versus those who did not (67% versus 78% for Stage B [P greater than 0.25] and 38% versus 47% for Stage C [P greater than 0.25], respectively). Also there was no significant difference in relapse-free survival rates between large and small field techniques (64% versus 77% for Stage B [P greater than 0.25] and 56% versus 41% for Stage C [P greater than 0.25], respectively). The 5-year and 7-year actuarial survival rates were 90% and 71%, respectively, for the 15 patients with residual tumor and 58% and 33%, respectively, for the 13 patients treated for postprostatectomy recurrence

  12. Time-dependent field equations for paraxial relativistic electron beams: Beam Research Program

    International Nuclear Information System (INIS)

    Sharp, W.M.; Yu, S.S.; Lee, E.P.

    1987-01-01

    A simplified set of field equations for a paraxial relativistic electron beam is presented. These equations for the beam electrostatic potential phi and pinch potential Phi identical to A/sub z/ - phi retain previously neglected time-dependent terms and for axisymmetric beams reduce exactly to Maxwell's equations

  13. Innovative energy efficient low-voltage electron beam emitters

    International Nuclear Information System (INIS)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-01-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates

  14. Innovative energy efficient low-voltage electron beam emitters

    Science.gov (United States)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-03-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates.

  15. Dose properties of a laser accelerated electron beam and prospects for clinical application

    International Nuclear Information System (INIS)

    Kainz, K.K.; Hogstrom, K.R.; Antolak, J.A.; Almond, P.R.; Bloch, C.D.; Chiu, C.; Fomytskyi, M.; Raischel, F.; Downer, M.; Tajima, T.

    2004-01-01

    Laser wakefield acceleration (LWFA) technology has evolved to where it should be evaluated for its potential as a future competitor to existing technology that produces electron and x-ray beams. The purpose of the present work is to investigate the dosimetric properties of an electron beam that should be achievable using existing LWFA technology, and to document the necessary improvements to make radiotherapy application for LWFA viable. This paper first qualitatively reviews the fundamental principles of LWFA and describes a potential design for a 30 cm accelerator chamber containing a gas target. Electron beam energy spectra, upon which our dose calculations are based, were obtained from a uniform energy distribution and from two-dimensional particle-in-cell (2D PIC) simulations. The 2D PIC simulation parameters are consistent with those reported by a previous LWFA experiment. According to the 2D PIC simulations, only approximately 0.3% of the LWFA electrons are emitted with an energy greater than 1 MeV. We studied only the high-energy electrons to determine their potential for clinical electron beams of central energy from 9 to 21 MeV. Each electron beam was broadened and flattened by designing a dual scattering foil system to produce a uniform beam (103%>off-axis ratio>95%) over a 25x25 cm2 field. An energy window (ΔE) ranging from 0.5 to 6.5 MeV was selected to study central-axis depth dose, beam flatness, and dose rate. Dose was calculated in water at a 100 cm source-to-surface distance using the EGS/BEAM Monte Carlo algorithm. Calculations showed that the beam flatness was fairly insensitive to ΔE. However, since the falloff of the depth-dose curve (R 10 -R 90 ) and the dose rate both increase with ΔE, a tradeoff between minimizing (R 10 -R 90 ) and maximizing dose rate is implied. If ΔE is constrained so that R 10 -R 90 is within 0.5 cm of its value for a monoenergetic beam, the maximum practical dose rate based on 2D PIC is approximately 0.1 Gy min-1

  16. Impact of field number and beam angle on functional image-guided lung cancer radiotherapy planning

    Science.gov (United States)

    Tahir, Bilal A.; Bragg, Chris M.; Wild, Jim M.; Swinscoe, James A.; Lawless, Sarah E.; Hart, Kerry A.; Hatton, Matthew Q.; Ireland, Rob H.

    2017-09-01

    To investigate the effect of beam angles and field number on functionally-guided intensity modulated radiotherapy (IMRT) normal lung avoidance treatment plans that incorporate hyperpolarised helium-3 magnetic resonance imaging (3He MRI) ventilation data. Eight non-small cell lung cancer patients had pre-treatment 3He MRI that was registered to inspiration breath-hold radiotherapy planning computed tomography. IMRT plans that minimised the volume of total lung receiving  ⩾20 Gy (V20) were compared with plans that minimised 3He MRI defined functional lung receiving  ⩾20 Gy (fV20). Coplanar IMRT plans using 5-field manually optimised beam angles and 9-field equidistant plans were also evaluated. For each pair of plans, the Wilcoxon signed ranks test was used to compare fV20 and the percentage of planning target volume (PTV) receiving 90% of the prescription dose (PTV90). Incorporation of 3He MRI led to median reductions in fV20 of 1.3% (range: 0.2-9.3% p  =  0.04) and 0.2% (range: 0 to 4.1%; p  =  0.012) for 5- and 9-field arrangements, respectively. There was no clinically significant difference in target coverage. Functionally-guided IMRT plans incorporating hyperpolarised 3He MRI information can reduce the dose received by ventilated lung without comprising PTV coverage. The effect was greater for optimised beam angles rather than uniformly spaced fields.

  17. Investigations of high mobility single crystal chemical vapor deposition diamond for radiotherapy photon beam monitoring

    Science.gov (United States)

    Tromson, D.; Descamps, C.; Tranchant, N.; Bergonzo, P.; Nesladek, M.; Isambert, A.

    2008-03-01

    The intrinsic properties of diamond make this material theoretically very suitable for applications in medical physics. Until now ionization chambers have been fabricated from natural stones and are commercialized by PTW, but their fairly high costs and long delivery times have often limited their use in hospital. The properties of commercialized intrinsic polycrystalline diamond were investigated in the past by many groups. The results were not completely satisfactory due to the nature of the polycrystalline material itself. In contrast, the recent progresses in the growth of high mobility single crystal synthetic diamonds prepared by chemical vapor deposition (CVD) technique offer new alternatives. In the framework of the MAESTRO project (Methods and Advanced Treatments and Simulations for Radio Oncology), the CEA-LIST is studying the potentialities of synthetic diamond for new techniques of irradiation such as intensity modulated radiation therapy. In this paper, we present the growth and characteristics of single crystal diamond prepared at CEA-LIST in the framework of the NoRHDia project (Novel Radiation Hard CVD Diamond Detector for Hadrons Physics), as well as the investigations of high mobility single crystal CVD diamond for radiotherapy photon beam monitoring: dosimetric analysis performed with the single crystal diamond detector in terms of stability and repeatability of the response signal, signal to noise ratio, response speed, linearity of the signal versus the absorbed dose, and dose rate. The measurements performed with photon beams using radiotherapy facilities demonstrate that single crystal CVD diamond is a good alternative for air ionization chambers for beam quality control.

  18. Reble, a radially converging electron beam accelerator

    International Nuclear Information System (INIS)

    Ramirez, J.J.; Prestwich, K.R.

    1976-01-01

    The Reble accelerator at Sandia Laboratories is described. This accelerator was developed to provide an experimental source for studying the relevant diode physics, beam propagation, beam energy deposition in a gas using a radially converging e-beam. The nominal parameters for Reble are 1 MV, 200 kA, 20 ns e-beam pulse. The anode and cathode are concentric cylinders with the anode as the inner cylinder. The radial beam can be propagated through the thin foil anode into the laser gas volume. The design and performance of the various components of the accelerator are presented

  19. The role of radiotherapy in the management of extrahepatic bile duct cancer: an analysis of 145 consecutive patients treated with intraluminal and/or external beam radiotherapy

    International Nuclear Information System (INIS)

    Kamada, Tadashi; Saitou, Hiroya; Takamura, Akio; Nojima, Takayuki; Okushiba, Shun-Ichi

    1996-01-01

    Purpose: To determine the feasibility of high dose radiotherapy and to evaluate its role in the management of extrahepatic bile duct (EHBD) cancer. Methods and Materials: Between 1983 and 1991, 145 consecutive patients with EHBD cancer were treated by low dose rate intraluminal 192 Ir irradiation (ILRT) either alone or in combination with external beam radiotherapy (EBRT). Among the primarily irradiated, 77 patients unsuitable for surgical resection, 54 were enrolled in radical radiotherapy, and 23 received palliative radiotherapy. Fifty-nine received postoperative radiotherapy, and the remaining 9 preoperative radiotherapy. The mean radiation dose was 67.8 Gy, ranging from 10 to 135 Gy. Intraluminal 192 Ir irradiation was indicated in 103 patients, and 85 of them were combined with EBRT. Expandable metallic biliary endoprosthesis (EMBE) was used in 32 primarily irradiated patients (31 radical and 1 palliative radiotherapy) after the completion of radiotherapy. Results: The 1-, 3-, and 5-year actuarial survival rates for all 145 patients were 55%, 18%, and 10%, for the 54 patients treated by radical radiotherapy (mean 83.1 Gy), 56%, 13%, and 6% [median survival time (MST) 12.4 months], and for the 59 patients receiving postoperative radiotherapy (mean 61.6 Gy), 73%, 31%, and 18% (MST 21.5 months), respectively. Expandable metallic biliary endoprosthesis was useful for the early establishment of an internal bile passage in radically irradiated patients and MST of 14.9 months in these 31 patients was significantly longer than that of 9.3 months in the remaining 23 patients without EMBE placement (p < 0.05). Eighteen patients whose surgical margins were positive in the hepatic side bile duct(s) showed significantly better survival compared with 15 patients whose surgical margins were positive in the adjacent structure(s) (44% vs. 0% survival at 3 years, p < 0.001). No survival benefit was obtained in patients given palliative or preoperative radiotherapy

  20. Isotope separation using tuned laser and electron beam

    International Nuclear Information System (INIS)

    Trajmar, S.

    1987-01-01

    The method for producing and separating a stream of a selected isotope from an atomic beam containing a mixture of isotopes is described comprising the steps of: (a) producing an atomic beam containing the isotope of interest and other isotopes; (b) producing a magnetic field to broaden the energy domain of the individual magnetic sublevels of the isotope of interest and having the atomic beam passing therethrough; (c) producing a laser beam; (d) adjusting the polarization of the laser beam to further maximize the activation of only individual magnetic sublevels of the isotope of interest; (e) aiming the laser beam to strike the atomic beam within the magnetic field and traverse the path of the atomic beam; (f) producing a collimated and high intensity beam of electrons within the magnetic field aimed to strike the atomic beam; and, (g) disposing deflection means to have the atomic beam pass therethrough after being struck by the electron beam and deflect the ionized isotope from the remainder of the beam to form a separate stream composed only of the isotope of interest

  1. Large-Area Plasmas Formed by Magnetically Confined Electron Beams

    Science.gov (United States)

    Fernsler, Richard; Meger, Robert; Lampe, Martin; Manheimer, Wallace; Murphy, Donald; Pechacek, Robert

    1998-10-01

    Magnetically confined electron beams can create plasmas in gas with less heating and greater control and uniformity than sources that produce ionization by heating the plasma electrons. Control is greater because the beam is generated separate from the plasma and steered using an external magnetic field. Uniformity is high because the beam current is constant along the propagation direction and confined magnetically in the transverse direction. And last, heating is reduced because energetic beam electrons ionize efficiently. That is, beam electrons typically require 30 eV of discharge energy per plasma electron formed, whereas conventional plasma sources require 100 eV and often much more. Based on these concepts, a Large Area Plasma Processing System (LAPPS) reactor has recently been built at the Naval Research Laboratory.(R. A. Meger et al., this conference) This reactor utilizes a long hollow-cathode glow discharge to generate a sheet electron beam of several keV in energy, and this beam produces planar plasmas up to 60 cm on a side by 2 cm thick with densities as high as 5x10^12 cm-3 in 30 mtorr of oxygen. Various aspects of beam-produced plasmas will be discussed including confinement and stability, efficiency of ionization and dissociation, cathode operation, and the effects of a low and adjustable plasma electron temperature.

  2. Proton beam radiotherapy for uveal melanoma: Results of Curie Institut-Orsay Proton Therapy Center (ICPO)

    International Nuclear Information System (INIS)

    Dendale, Remi; Lumbroso-Le Rouic, Livia; Noel, Georges; Feuvret, Loic; Levy, Christine; Delacroix, Sabine; Meyer, Anne; Nauraye, Catherine; Mazal, Alejandro; Mammar, Hamid; Garcia, Paul; D'Hermies, Francois; Frau, Eric; Plancher, Corine; Asselain, Bernard; Schlienger, Pierre; Mazeron, Jean Jacques; Desjardins, Laurence

    2006-01-01

    Purpose: This study reports the results of proton beam radiotherapy based on a retrospective series of patients treated for uveal melanoma at the Orsay Center. Methods and Materials: Between September 1991 and September 2001, 1,406 patients with uveal melanoma were treated by proton beam radiotherapy. A total dose of 60 cobalt Gray equivalent (CGE) was delivered in 4 fractions on 4 days. Survival rates were determined using Kaplan-Meier estimates. Prognostic factors were determined by multivariate analysis using the Cox model. Results: The median follow-up was 73 months (range, 24-142 months). The 5-year overall survival and metastasis-free survival rates were 79% and 80.6%, respectively. The 5-year local control rate was 96%. The 5-year enucleation for complications rate was 7.7%. Independent prognostic factors for overall survival were age (p < 0.0001), gender (p < 0.0003), tumor site (p < 0.0001), tumor thickness (p = 0.02), tumor diameter (p < 0.0001), and retinal area receiving at least 30 CGE (p = 0.003). Independent prognostic factors for metastasis-free survival were age (p = 0.0042), retinal detachment (p = 0.01), tumor site (p < 0.0001), tumor volume (p < 0.0001), local recurrence (p < 0.0001), and retinal area receiving at least 30 CGE (p = 0.002). Independent prognostic factors for local control were tumor diameter (p = 0.003) and macular area receiving at least 30 CGE (p = 0.01). Independent prognostic factors for enucleation for complications were tumor thickness (p < 0.0001) and lens volume receiving at least 30 CGE (p = 0.0002). Conclusion: This retrospective study confirms that proton beam radiotherapy ensures an excellent local control rate. Further clinical studies are required to decrease the incidence of postirradiation ocular complications

  3. Pulsed electron beam propagation in argon and nitrogen gas mixture

    Science.gov (United States)

    Kholodnaya, G. E.; Sazonov, R. V.; Ponomarev, D. V.; Remnev, G. E.; Zhirkov, I. S.

    2015-10-01

    The paper presents the results of current measurements for the electron beam, propagating inside a drift tube filled in with a gas mixture (Ar and N2). The experiments were performed using the TEA-500 pulsed electron accelerator. The main characteristics of electron beam were as follows: 60 ns pulse duration, up to 200 J energy, and 5 cm diameter. The electron beam propagated inside the drift tube assembled of three sections. Gas pressures inside the drift tube were 760 ± 3, 300 ± 3, and 50 ± 1 Torr. The studies were performed in argon, nitrogen, and their mixtures of 33%, 50%, and 66% volume concentrations, respectively.

  4. Electron beam modification of vanadium dioxide oscillators

    Energy Technology Data Exchange (ETDEWEB)

    Belyaev, Maksim; Velichko, Andrey; Putrolaynen, Vadim; Perminov, Valentin; Pergament, Alexander [Petrozavodsk State University, Petrozavodsk (Russian Federation)

    2017-03-15

    The paper presents the results of a study of electron-beam modification (EBM) of VO{sub 2}-switch I-V curve threshold parameters and the self-oscillation frequency of a circuit containing such a switching device. EBM in vacuum is reversible and the parameters are restored when exposed to air at pressure of 150 Pa. At EBM with a dose of 3 C cm{sup -2}, the voltages of switching-on (V{sub th}) and off (V{sub h}), as well as the OFF-state resistance R{sub off}, decrease down to 50% of the initial values, and the oscillation frequency increases by 30% at a dose of 0.7 C cm{sup -2}. Features of physics of EBM of an oscillator are outlined considering the contribution of the metal and semiconductor phases of the switching channel. Controlled modification allows EBM forming of switches with preset parameters. Also, it might be used in artificial oscillatory neural networks for pattern recognition based on frequency shift keying. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Electron Beam Treatment of Toxic Chemicals

    International Nuclear Information System (INIS)

    Jung, In Ha; Lee, Myun Joo; Lee, Oh Mi; Kim, Tae Hoon

    2011-01-01

    Polychlorinated biphenyls (PCBs) were commercially produced from 1920s as complex mixtures containing multiple isomers for a variety of applications. They are very toxic, chemically stable and resist microbial, photochemical, chemical, and thermal degradation. The public, legal, and scientific concerns about PCBs arose from research indicating they were environmental contaminants that had a potential to adversely impact the environment, and, therefore, were undesirable as commercial products. Eventually, most producers reduced or stopped production of PCBs in the 1970s. Stockholm convention on POPs (Persistent Organic Pollutants), which was effective on May 2004 and 151 nations including Korea were joined on June 2005, asked to dispose of PCBs by 2028 with environmental friendly methods. Korean government also has declared to perform by 2015. According to the Environmental law of Korea, over 2 ppm of PCBs has to be decomposed by legal methods of incineration and thermal destruction. But those are inapplicable owing to the environmental groups. KAERI(Korea Atomic Energy Research Institute) has recently developed a remarkable technology for radiation treatment of toxic chemicals including chlorides using an electron beam accelerator

  6. Applications of electron beam in nanotechnology

    International Nuclear Information System (INIS)

    Khairul Zaman Hj. Mohd Dahlan; Jamaliah Sharif

    2005-01-01

    The use of radiation technique to process nanostructured materials or to produce nanostructured materials have been shown technically superior as alternative and viable techniques for further commercial exploitation. Research on radiation processing of nanocomposites have been initiated at the Radiation Processing Technology Division of MINT in the past three years. The main focus of this research is to utilize indigenous natural polymer for production of nanocomposites material. Natural rubber/clay composites and thermoplastic natural rubber/clay composites are the important materials that under studied. The natural rubber used in this work is of grade SMRL (Standard Malaysian Rubber) and the clay used was sodium montmorillonite modified with various types of cationic surfactants in order to make the galleries hydrophobic and thus more compatible with the elastomer. The natural rubber/clay nanocomposites were prepared by melt mixing. The compound was then irradiated using electron beam at optimum dose of 250 kGy. X-ray diffraction results indicated intercalation of the natural rubber into silicate interlayer. Upon irradiation at 250 kGy, the tensile strength of the NR/Na-MMT nanocomposites constantly reduced slightly with increasing clay loading, whereas the tensile strengths of NR/DDA-MMT and NR/ODA-MMT increases to optimum levels, 12.1 MPa and 9.5 MPa respectively at 3 phr clay contents. On the other hand, the elongation of NR/DDA-MMT nanocomposites is less affected with increasing clay content up to 3 phr. (author)

  7. Heat shrinkage of electron beam modified EVA

    International Nuclear Information System (INIS)

    Datta, S.K.; Chaki, T.K.; Bhowmick, A.K.

    1997-01-01

    Heat shrinkage of electron beam modified ethylene vinyl acetate copolymer (EVA) has been investigated over a range of times, temperatures, stretching, irradiation doses and trimethylolpropane trimethacrylate (TMPTMA) levels. The irradiated (radiation dose 50 kGy and TMPTMA level 1%) and stretched (100% elongation) sample shrinks to a maximum level when kept at 453K temperature for 60 s. The heat shrinkage of samples irradiated with radiation doses of 20, 50, 100 and 150 kGy increases sharply with increasing stretching in the initial stage. Amnesia rating decreases with increasing radiation dose and TMPTMA level as well as gel content. The high radiation dose and TMPTMA level lower the heat shrinkage due to the chain scission. The effect of temperature at which extension is carried out on heat shrinkage is marginal. The irradiated (radiation dose 50 kGy and TMPTMA level 1%) EVA tubes of different dimensions expanded in a laboratory grade tube expander show similar behaviour at 453K and 60 s. The X-ray and DSC studies reveal that the crystallinity increases on stretching due to orientation of chains and it decreases to a considerable extent on heat shrinking. The theoretical and experimental values of heat shrinkage for tubes and rectangular strips are in good accord, when the radiation dose is 50 kGy and TMPTMA level 1%. (author)

  8. Heat shrinkage of electron beam modified EVA

    Energy Technology Data Exchange (ETDEWEB)

    Datta, S.K.; Chaki, T.K.; Bhowmick, A.K. [Indian Institute of Technology, Kharagpur (India). Rubber Technology Center; Tikku, V.K.; Pradhan, N.K. [NICCO Corporation Ltd., (Cable Div.), Calcutta (India)

    1997-10-01

    Heat shrinkage of electron beam modified ethylene vinyl acetate copolymer (EVA) has been investigated over a range of times, temperatures, stretching, irradiation doses and trimethylolpropane trimethacrylate (TMPTMA) levels. The irradiated (radiation dose 50 kGy and TMPTMA level 1%) and stretched (100% elongation) sample shrinks to a maximum level when kept at 453K temperature for 60 s. The heat shrinkage of samples irradiated with radiation doses of 20, 50, 100 and 150 kGy increases sharply with increasing stretching in the initial stage. Amnesia rating decreases with increasing radiation dose and TMPTMA level as well as gel content. The high radiation dose and TMPTMA level lower the heat shrinkage due to the chain scission. The effect of temperature at which extension is carried out on heat shrinkage is marginal. The irradiated (radiation dose 50 kGy and TMPTMA level 1%) EVA tubes of different dimensions expanded in a laboratory grade tube expander show similar behaviour at 453K and 60 s. The X-ray and DSC studies reveal that the crystallinity increases on stretching due to orientation of chains and it decreases to a considerable extent on heat shrinking. The theoretical and experimental values of heat shrinkage for tubes and rectangular strips are in good accord, when the radiation dose is 50 kGy and TMPTMA level 1%. (author).

  9. Experiments on Ion Beam Space-Charge Neutralization with Pulsed Electron Beams

    CERN Document Server

    Herleb, U

    1998-01-01

    Space-charge neutralization of heavy ion beams with electron beam pulses generated by electron guns incorporating ferroelectric cathodes has been experimentally investigated. Several experiments are described, the results of which prove that the intensity of selected ion beam parts with defined charge states generated in a laser ion source can be increased by an order of magnitude. For elevated charge states the intensity amplification is more significant than for low charge states. A charge enhancement factor of four has been achieved by neutralization with pulsed electron beams for Al7+ ions generated from an aluminium target.

  10. Radiotherapy

    International Nuclear Information System (INIS)

    Zedgenidze, G.A.; Kulikov, V.A.; Mardynskij, Yu.S.

    1984-01-01

    The technique for roentgenotopometric and medicamentous preparation of patients for radiotherapy has been reported in detail. The features of planning and performing of remote, intracavitary and combined therapy in urinary bladder cancer are considered. The more effective methods of radiotherapy have been proposed taking into account own experience as well as literature data. The comparative evaluation of treatment results and prognosis are given. Radiation pathomorphism of tumors and tissues of urinary bladder is considered in detail. The problems of diagnosis, prophylaxis and treatment of complications following radiodiagnosis and radiotherapy in patients with urinary bladder cancer are illustrated widely

  11. Renormalization theory of beam-beam interaction in electron-positron colliders

    International Nuclear Information System (INIS)

    Chin, Y.H.

    1989-07-01

    This note is devoted to explaining the essence of the renormalization theory of beam-beam interaction for carrying out analytical calculations of equilibrium particle distributions in electron-positron colliding beam storage rings. Some new numerical examples are presented such as for betatron tune dependence of the rms beam size. The theory shows reasonably good agreements with the results of computer simulations. 5 refs., 6 figs

  12. Ion and electron beam interaction on surfaces - a detection mechanism for obtaining visual ion beam images

    International Nuclear Information System (INIS)

    Fine, J.; Gorden, R. Jr.

    1978-01-01

    Two-dimensional images have been obtained of ion beam impact cross sections on solid surfaces by the coincident interaction of a rastered electron beam. This detection method is effective in producing images in real time on various insulator surfaces. The size of these images correlates well with ion beam current density profile measurements (at full width) and, therefore, can be very useful for ion beam diagnostics and alignment. (Auth.)

  13. Exact suppression of depolarisation by beam-beam interaction in an electron ring

    International Nuclear Information System (INIS)

    Buon, J.

    1983-03-01

    It is shown that depolarisation due to beam-beam interaction can be exactly suppressed in an electron storage ring. The necessary ''spin matching'' conditions to be fulfilled are derived for a planar ring. They depend on the ring optics, assumed linear, but not on the features of the beam-beam force, like intensity and non-linearity. Extension to a ring equipped with 90 0 spin rotators is straightorward

  14. Electron Beam Energy Compensation by Controlling RF Pulse Shape

    CERN Document Server

    Kii, T; Kusukame, K; Masuda, K; Nakai, Y; Ohgaki, H; Yamazaki, T; Yoshikawa, K; Zen, H

    2005-01-01

    We have studied on improvement of electron beam macropulse properties from a thermionic RF gun. Though a thermionic RF gun has many salient features, there is a serious problem that back-bombardment effect worsens quality of the beam. To reduce beam energy degradation by this effect, we tried to feed non-flat RF power into the gun. As a result, we successfully obtained about 1.5 times longer macropulse and two times larger total charge per macropulse. On the other hand, we calculated transient evolution of RF power considering non-constant beam loading. The beam loading is evaluated from time evolution of cathode temperature, by use of one dimensional heat conduction model and electron trajectories' calculations by a particle simulation code. Then we found good agreement between the experimental and calculation results. Furthermore, with the same way, we studied the electron beam output dependence on the cathode radius.

  15. Electron-beam induced conduction in some polymers

    International Nuclear Information System (INIS)

    Suzuoki, Yasuo; Mizutani, Teruyoshi; Ieda, Masayuki

    1976-01-01

    The charge signal induced by pulsed electron beam consists of two components, i.e. the fast and the slow components. The slow component which corresponds to carrier transport via shallow traps exhibited an asymmetry with respect to the bias field polarity. The asymmetry revealed that the main carriers which drifted via shallow traps were electrons in PET, both electrons and holes in PEN, and holes in PS. TSC spectra of electron-beam induced electrets proved directly the existence of electron shallow traps in PET and both electron and hole traps in PEN. Their trap energies were 0.1 to 0.2 eV. (auth.)

  16. Generation of an intense ion beam by a pinched relativistic electron beam

    International Nuclear Information System (INIS)

    Gilad, P.; Zinamon, Z.

    1976-01-01

    The pinched electron beam of a pulsed electron accelerator is used to generate an intense beam of ions. A foil anode and vacuum drift tube are used. The space charge field of the pinched beam in the tube accelerates ions from the foil anode. Ion currents of 10 kA at a density of 5kA/cm 2 with pulse length of 50 ns are obtained using a 5 kJ, 450 kV, 3 Ω diode. (author)

  17. The target volume concept at the recording of external beam radiotherapy

    International Nuclear Information System (INIS)

    Quast, U.; Glaeser, L.

    1981-01-01

    With the aim of complete, exact and reproducible manual recording and documentation of external beam radiotherapy a concept is proposed providing treatment planning and recording related to space and time for target volumes of different order corresponding to Ist, IInd or IIIrd part of treatment course, regarding all dose limiting organs at risk. The record consists of the dosage plan for medical treatment planning, the treatment plan for physical dose distribution planning and the treatment record of absorbed doses delivered as well as a checklist for patient and machine set-up, and labels for intended actions during treatment development. A clear arrangement of the record form in logical order was found, demanding exact specification of target(s) and beam(s) and their relation in space and time; asking for verbal and graphical description of target volumes, organs at risk, patient positioning, beam portals and dose reference points in terms of patients' anatomy; emphasizing the most important medical data by marked areas and leaving enough empty space for additional data, remarks or comments. During several years of clinical use these record forms proved to be suitable for all cases of external beam therapy, for complex situations of target volumes and treatment-scheduling, for all treatment techniques and radiation qualities and for all ways of physical treatment planning. They can be extended to automatic treatment verification, monitoring and recording as well as to the application of in-vivo-measurements of absorbed doses. (orig.) [de

  18. Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy.

    Science.gov (United States)

    Korpics, Mark; Johnson, Paul; Patel, Rakesh; Surucu, Murat; Choi, Mehee; Emami, Bahman; Roeske, John C

    2016-12-01

    To evaluate a method for reducing metal artifacts, arising from dental fillings, on cone-beam computed tomography images. A projection interpolation algorithm is applied to cone-beam computed tomography images containing metal artifacts from dental fillings. This technique involves identifying metal regions in individual cone-beam computed tomography projections and interpolating the surrounding values to remove the metal from the projection data. Axial cone-beam computed tomography images are then reconstructed, resulting in a reduction in the streak artifacts produced by the metal. Both phantom and patient imaging data are used to evaluate this technique. The interpolation substitution technique successfully reduced metal artifacts in all cases. Corrected images had fewer or no streak artifacts compared to their noncorrected counterparts. Quantitatively, regions of interest containing the artifacts showed reduced variance in the corrected images versus the uncorrected images. Average pixel values in regions of interest around the metal object were also closer in value to nonmetal regions after artifact reduction. Artifact correction tended to perform better on patient images with less complex metal objects versus those with multiple large dental fillings. The interpolation substitution is potentially an efficient and effective technique for reducing metal artifacts caused by dental fillings on cone-beam computed tomography image. This technique may be effective in reducing such artifacts in patients with head and neck cancer receiving daily image-guided radiotherapy. © The Author(s) 2015.

  19. Generation and application of bessel beams in electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Grillo, Vincenzo, E-mail: vincenzo.grillo@cnr.it [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); CNR-IMEM, Parco Area delle Scienze 37/A, I-43124 Parma (Italy); Harris, Jérémie [Department of Physics, University of Ottawa, 25 Templeton St., Ottawa, Ontario, Canada K1N 6N5 (Canada); Gazzadi, Gian Carlo [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Balboni, Roberto [CNR-IMM Bologna, Via P. Gobetti 101, 40129 Bologna (Italy); Mafakheri, Erfan [Dipartimento di Fisica Informatica e Matematica, Università di Modena e Reggio Emilia, via G Campi 213/a, I-41125 Modena (Italy); Dennis, Mark R. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Frabboni, Stefano [CNR-Istituto Nanoscienze, Centro S3, Via G Campi 213/a, I-41125 Modena (Italy); Dipartimento di Fisica Informatica e Matematica, Università di Modena e Reggio Emilia, via G Campi 213/a, I-41125 Modena (Italy); Boyd, Robert W.; Karimi, Ebrahim [Department of Physics, University of Ottawa, 25 Templeton St., Ottawa, Ontario, Canada K1N 6N5 (Canada)

    2016-07-15

    We report a systematic treatment of the holographic generation of electron Bessel beams, with a view to applications in electron microscopy. We describe in detail the theory underlying hologram patterning, as well as the actual electron-optical configuration used experimentally. We show that by optimizing our nanofabrication recipe, electron Bessel beams can be generated with relative efficiencies reaching 37±3%. We also demonstrate by tuning various hologram parameters that electron Bessel beams can be produced with many visible rings, making them ideal for interferometric applications, or in more highly localized forms with fewer rings, more suitable for imaging. We describe the settings required to tune beam localization in this way, and explore beam and hologram configurations that allow the convergences and topological charges of electron Bessel beams to be controlled. We also characterize the phase structure of the Bessel beams generated with our technique, using a simulation procedure that accounts for imperfections in the hologram manufacturing process. - Highlights: • Bessel beams with different convergence, topological charge, visible fringes are demonstrated. • The relation between the Fresnel hologram and the probe shape is explained by detailed calculations and experiments. • Among the holograms here presented the highest relative efficiency is 37%, the best result ever reached for blazed holograms.

  20. Delivery of modulated electron beams with conventional photon multi-leaf collimators

    International Nuclear Information System (INIS)

    Klein, Eric E; Mamalui-Hunter, Maria; Low, Daniel A

    2009-01-01

    Electron beam radiotherapy is an accepted method to treat shallow tumors. However, modulation of electrons to customize dose distributions has not readily been achieved. Studies of bolus and tertiary collimation systems have been met with limitations. We pursue the use of photon multi-leaf collimators (MLC) for modulated electron radiotherapy (MERT) to achieve customized distributions for potential clinical use. As commercial planning systems do not support the use of MLC with electrons, planning was conducted using Monte Carlo calculations. Segmented and dynamic modulated delivery of multiple electron segments was configured, calculated and delivered for validation. Delivery of electrons with segmented or dynamic leaf motion was conducted. A phantom possessing an idealized stepped target was planned and optimized with subsequent validation by measurements. Finally, clinical treatment plans were conducted for post-mastectomy and cutaneous lymphoma of the scalp using forward optimization techniques. Comparison of calculations and measurements was successful with agreement of ±2%/2 mm for the energies, segment sizes, depths tested for delivered segments for the dynamic and segmented delivery. Clinical treatment plans performed provided optimal dose coverage of the target while sparing distal organs at risk. Execution of plans using an anthropomorphic phantom to ensure safe and efficient delivery was conducted. Our study validates that MERT is not only possible using the photon MLC, but the efficient and safe delivery inherent with the dynamic delivery provides an ideal technique for shallow tumor treatment.

  1. Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery

    International Nuclear Information System (INIS)

    Schlosser, Jeffrey; Salisbury, Kenneth; Hristov, Dimitre

    2010-01-01

    would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences. Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

  2. Measuring the electron beam energy in a magnetic bunch compressor

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Kirsten

    2010-09-15

    Within this thesis, work was carried out in and around the first bunch compressor chicane of the FLASH (Free-electron LASer in Hamburg) linear accelerator in which two distinct systems were developed for the measurement of an electron beams' position with sub-5 {mu}m precision over a 10 cm range. One of these two systems utilized RF techniques to measure the difference between the arrival-times of two broadband electrical pulses generated by the passage of the electron beam adjacent to a pickup antenna. The other system measured the arrival-times of the pulses from the pickup with an optical technique dependent on the delivery of laser pulses which are synchronized to the RF reference of the machine. The relative advantages and disadvantages of these two techniques are explored and compared to other available approaches to measure the same beam property, including a time-of-flight measurement with two beam arrival-time monitors and a synchrotron light monitor with two photomultiplier tubes. The electron beam position measurement is required as part of a measurement of the electron beam energy and could be used in an intra-bunch-train beam-based feedback system that would stabilize the amplitude of the accelerating field. By stabilizing the accelerating field amplitude, the arrival-time of the electron beam can be made more stable. By stabilizing the electron beam arrival-time relative to a stable reference, diagnostic, seeding, and beam-manipulation lasers can be synchronized to the beam. (orig.)

  3. Inhomogeneities in high energy photon beams used in radiotherapy. Experimental and theoretical studies

    International Nuclear Information System (INIS)

    Kappas, K.

    1986-01-01

    This work is dedicated to the influence of the human body inhomogeneities on the dose distribution for high energy photons beams used in Radiotherapy. It consists in an experimental part and a theoretical analysis leading to original models of calculation. We study essentially, - the beam quality of the machines used and its influence on some basic dosimetric quantities and on the response of an ionization chamber. - The dose perturbation due to off-axis heterogeneous volumes at off-axis points of measurement; a model is suggested to take into account the perturbation of the multiple scatter. The perturbation of the dose in the transition region, between water equivalent medium and heterogeneous medium (air) is also investigated. The last part is devoted to computer applications of the proposed correction methods and to a comparison between the different computerized treatment planning systems which take into account of inhomogeneities [fr

  4. Electron beam charge state amplifier (EBQA)--a conceptual evaluation

    International Nuclear Information System (INIS)

    Dooling, J. C.

    1998-01-01

    A concept is presented for stripping low-energy, radioactive ions from 1+ to higher charge states. Referred to as an Electron Beam Charge State Amplifier (EBQA), this device accepts a continuous beam of singly-charged, radioactive ions and passes them through a high-density electron beam confined by a solenoidal magnetic field. Singly-charged ions may be extracted from standard Isotope-Separator-Online (ISOL) sources. An EBQA is potentially useful for increasing the charge state of ions prior to injection into post-acceleration stages at ISOL radioactive beam facilities. The stripping efficiency from q=1+ to 2+ (η 12 ) is evaluated as a function of electron beam radius at constant current with solenoid field, injected ion energy, and ion beam emittance used as parameters. Assuming a 5 keV, 1 A electron beam, η 12 = 0.38 for 0.1 keV, 132 Xe ions passing through an 8 Tesla solenoid, 1 m in length. Multi-pass configurations to achieve 3+ or 4+ charge states are also conceivable. The calculated efficiencies depend inversely on the initial ion beam emittances. The use of a helium-buffer-gas, ion-guide stage to improve the brightness of the 1+ beams [1] may enhance the performance of an EBQA

  5. Electron beam curing of acrylic oligomers

    International Nuclear Information System (INIS)

    Seto, J.; Arakawa, S.; Ishimoto, C.; Miyashita, M.; Nagai, T.; Noguchi, T.; Shibata, A.

    1984-01-01

    The electron-beam curing process of acrylic oligomers, with and without γ-Fe 2 O 3 pigment filler and blended linear polymer, was investigated in terms of molecular structure and reaction mechanism. The polymerized fraction of trimethylolpropane-triacrylate (TMPTA) oligomers increases with increasing total dose, and is independent of the dose rate. Since the reaction rate is linearly dependent on the dose rate, the reaction mechanism involves monomolecular termination. The reaction rate does not depend on the number of functional groups of the oligomer at low doses, but above 0.3 Mrad the rate is slower for oligomers of higher functionality. A gel is formed more readily upon curing of a polyfunctional than a monofunctional oligomer, especially at high conversion to polymer; the resulting loss of flexibility of the polymer chains slows the reaction. Decrease of the molecular weight per functional group results in lower conversion; this is also due to the loss of chain flexibility, which is indicated as well by a higher glass-transition temperature. Modification of the acrylate oligomers with urethane results in more effective cross-linking reactions because of the more rigid molecular chains. Addition of γ-Fe 2 O 3 pigment reduces the reaction rate very little, but has the effect of providing added structural integrity, as indicated by the decrease of solvent-extractable material and the improvement of anti-abrasion properties. However, the flexibility of the coating and its adhesion to a PET base film are diminished. To increase the flexibility, linear polyvinylchloride and/or polyurethane were added to the acrylic oligomers. Final conversion to polymer was nearly 100 percent, and a higher elastic modulus and better antiabrasion properties were realized

  6. Single-electrode monitors for relativistic intense electron beam parameters

    International Nuclear Information System (INIS)

    Stratienko, V.A.; Khorenko, V.K.

    1977-01-01

    A single-electrode monitor operating in atmosphere on delta-electrons for precision measurement of high-intensity electron beams is developed. As an emitter is used a 0.2 mm aluminium foil with a hole which is a replica of the sample subjected to radiation. The electric charge from the emitter is recorded by a current integrator. The single-electrode monitor enabled to form a 225 MeV electron beam with a flux density of 5x10 15 electrons/ (cm 2 and confine the latter for 140 hours with an accuracy of +- 0.2 mm. Controlling the beam shifting by means of the single-electrode monitor described, it is possible to measure the real dimensions and density distributions of high-intensity electron beams

  7. An Electron-Beam Profile Monitor Using Fresnel Zone Plates

    International Nuclear Information System (INIS)

    Nakamura, Norio; Sakai, Hiroshi; Iida, Kensuke; Shinoe, Kenji; Takaki, Hiroyuki; Fujisawa, Masami; Hayano, Hitoshi; Muto, Toshiya; Nomura, Masaharu; Kamiya, Yukihide; Koseki, Tadashi; Amemiya, Yoshiyuki; Aoki, Nobutada; Nakayama, Koichi

    2004-01-01

    We have developed a beam profile monitor using two Fresnel zone plates (FZPs) at the KEK-ATF (Accelerator Test Facility) damping ring to measure small electron-beam sizes for low-emittance synchrotron radiation sources. The monitor has a structure of an X-ray microscope, where two FZPs constitute an X-ray imaging optics. In the monitor system, the synchrotron radiation from the electron beam at the bending magnet is monochromatized to 3.235-keV X-rays by a crystal monochromator and the transverse electron-beam image is twenty-times magnified by the two FZPs and detected on an X-ray CCD camera. This monitor has the following advantages: (1) high spatial resolution, (2) non-destructive measurement, (3) real-time monitoring, and (4) direct electron-beam imaging. With the beam profile monitor, we have succeeded in obtaining a clear electron-beam image and measuring the extremely small beam size less than 10 μm. The measured magnification of the imaging optics was in good agreement with the design value

  8. Electron beam characterization of a combined diode rf electron gun

    Directory of Open Access Journals (Sweden)

    R. Ganter

    2010-09-01

    Full Text Available Experimental and simulation results of an electron gun test facility, based on pulsed diode acceleration followed by a two-cell rf cavity at 1.5 GHz, are presented here. The main features of this diode-rf combination are: a high peak gradient in the diode (up to 100  MV/m obtained without breakdown conditioning, a cathode shape providing an electrostatic focusing, and an in-vacuum pulsed solenoid to focus the electron beam between the diode and the rf cavity. Although the test stand was initially developed for testing field emitter arrays cathodes, it became also interesting to explore the limits of this electron gun with metallic photocathodes illuminated by laser pulses. The ultimate goal of this test facility is to fulfill the requirements of the SwissFEL project of Paul Scherrer Institute [B. D. Patterson et al., New J. Phys. 12, 035012 (2010NJOPFM1367-263010.1088/1367-2630/12/3/035012]; a projected normalized emittance below 0.4  μm for a charge of 200 pC and a bunch length of less than 10 ps (rms. A normalized projected emittance of 0.23  μm with 13 pC has been measured at 5 MeV using a Gaussian laser longitudinal intensity distribution on the photocathode. Good agreements with simulations have been obtained for different electron bunch charge and diode geometries. Emittance measurements at a bunch charge below 1 pC were performed for different laser spot sizes in agreement with intrinsic emittance theory [e.g. 0.54  μm/mm of laser spot size (rms for Cu at 274 nm]. Finally, a projected emittance of 1.25+/-0.2  μm was measured with 200 pC and 100  MV/m diode gradient.

  9. Measurement of electron beam bunch phase length by rectangular cavities

    International Nuclear Information System (INIS)

    Afanas'ev, V.D.; Rudychev, V.G.; Ushakov, V.I.

    1976-01-01

    An analysis of a phase length of electron bunches with the help of crossed rectangular resonators with the Hsub(102) oscillation type has been made. It has been shown that the electron coordinates after the duplex resonator are described by an ellipse equation for a non-modulated beam. An influence of the initial energy spread upon the electron motion has been studied. It has been ascertained that energy modulation of the electron beam results in displacement of each electron with respect to the ellipse which is proportional to modulation energy, i.e. an error in determination of the phase length of an electron bunch is proportional to the beam energy spread. Relations have been obtained which enable to find genuine values of phases of the analyzed electrons with an accuracy up to linear multipliers

  10. Patterned electrochemical deposition of copper using an electron beam

    Directory of Open Access Journals (Sweden)

    Mark den Heijer

    2014-02-01

    Full Text Available We describe a technique for patterning clusters of metal using electrochemical deposition. By operating an electrochemical cell in the transmission electron microscope, we deposit Cu on Au under potentiostatic conditions. For acidified copper sulphate electrolytes, nucleation occurs uniformly over the electrode. However, when chloride ions are added there is a range of applied potentials over which nucleation occurs only in areas irradiated by the electron beam. By scanning the beam we control nucleation to form patterns of deposited copper. We discuss the mechanism for this effect in terms of electron beam-induced reactions with copper chloride, and consider possible applications.

  11. The simulation of the electron beam spot control

    Directory of Open Access Journals (Sweden)

    Stelian Emilian Oltean

    2011-12-01

    Full Text Available Electron beams have many special properties which make them particularly well suited for use in materials processing, wherever conventional techniques failed or proved to be inefficient. The entire process has a lot of time varying parameters, so using a distributed control system for 3d position of the electron beam spot may improve the quality of the material processing. Matlab environment was used for model implementation and simulations of the control system which contains the focusing and deflecting components. Due the nature of the process and knowing the electron beam equipment we proposed for the simulations scenarios with a 3D virtual surface.

  12. Electron-beam chest-wall irradiation in breast cancer patients after mastectomy

    International Nuclear Information System (INIS)

    He Zhenyu; Guo Jun; Wu San'gang; Li Fengyan; Lin Huanxin; Guan Xunxing

    2011-01-01

    Objective: To evaluate the efficacy of electron-beam chest-wall irradiation in patients with breast cancer after mastectomy. Methods: From June 1999 to December 2007, 280 women with localized breast cancer received postmastectomy radiotherapy using electron beam to chest wall. The efficacy and toxicity of these 280 women was compared with 118 women treated during the same period using tangential field with photon beam. Results: The follow-up rate was 93.2%. 140 patients had a minimum followed up time of 5 years and 12 patients had a minimum follow up time of 10 years. The 5-year and 10-year chest wall recurrence rates were 6.8% and 5.0%. 14.8% and 10.1% for patients irradiated with electron and photon (χ 2 =1.12, P=0.290). The corresponding 5-year and 10-year disease-free survival rates were 60.6% and 65.5%, 47.6% and 57.3% (χ 2 =0.97, P=0.325). The 5-year and 10-year overall survival rates were 77.5% and 79.6%, 48.4% and 53.3% (χ 2 =0.37, P=0.545). Grade II or more acute skin toxicity occurred in 10.4% and 16.9% of patients irradiated with electron and photon (χ 2 =3.34, P=0.090). Pulmonary fibrosis developed in 28.8% and 22.1% of patients irradiated with electron and photon (χ 2 =1.27, P=0.300). Conclusion: Electron-beam chest-wall irradiation is as effective as photon-beam irradiation in breast cancer after mastectomy. (authors)

  13. High energy gain electron beam acceleration by 100TW laser

    International Nuclear Information System (INIS)

    Kotaki, Hideyuki; Kando, Masaki; Kondo, Shuji; Hosokai, Tomonao; Kanazawa, Shuhei; Yokoyama, Takashi; Matoba, Toru; Nakajima, Kazuhisa

    2001-01-01

    A laser wakefield acceleration experiment using a 100TW laser is planed at JAERI-Kansai. High quality and short pulse electron beams are necessary to accelerate the electron beam by the laser. Electron beam - laser synchronization is also necessary. A microtron with a photocathode rf-gun was prepared as a high quality electron injector. The quantum efficiency (QE) of the photocathode of 2x10 -5 was obtained. A charge of 100pC from the microtron was measured. The emittance and pulse width of the electron beam was 6π mm-mrad and 10ps, respectively. In order to produce a short pulse electron beam, and to synchronize between the electron beam and the laser pulse, an inverse free electron laser (IFEL) is planned. One of problems of LWFA is the short acceleration length. In order to overcome the problem, a Z-pinch plasma waveguide will be prepared as a laser wakefield acceleration tube for 1 GeV acceleration. (author)

  14. A compact, versatile low-energy electron beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Zschornack, G., E-mail: g.zschornack@hzdr.de [Department of Physics, Dresden University of Technology, 01062 Dresden, Germany and Helmholtz-Zentrum Dresden-Rossendorf, Institute of Ion Beam Physics and Materials Research, 01328 Dresden (Germany); König, J.; Schmidt, M.; Thorn, A. [DREEBIT GmbH, 01109 Dresden (Germany)

    2014-02-15

    A new compact Electron Beam Ion Source, the Dresden EBIT-LE, is introduced as an ion source working at low electron beam energies. The EBIT-LE operates at an electron energy ranging from 100 eV to some keV and can easily be modified to an EBIT also working at higher electron beam energies of up to 15 keV. We show that, depending on the electron beam energy, electron beam currents from a few mA in the low-energy regime up to about 40 mA in the high-energy regime are possible. Technical solutions as well as first experimental results of the EBIT-LE are presented. In ion extraction experiments, a stable production of low and intermediate charged ions at electron beam energies below 2 keV is demonstrated. Furthermore, X-ray spectroscopy measurements confirm the possibility of using the machine as a source of X-rays from ions excited at low electron energies.

  15. Dose properties of x-ray beams produced by laser-wakefield-accelerated electrons

    International Nuclear Information System (INIS)

    Kainz, K K; Hogstrom, K R; Antolak, J A; Almond, P R; Bloch, C D

    2005-01-01

    Given that laser wakefield acceleration (LWFA) has been demonstrated experimentally to accelerate electron beams to energies beyond 25 MeV, it is reasonable to assess the ability of existing LWFA technology to compete with conventional radiofrequency linear accelerators in producing electron and x-ray beams for external-beam radiotherapy. We present calculations of the dose distributions (off-axis dose profiles and central-axis depth dose) and dose rates of x-ray beams that can be produced from electron beams that are generated using state-of-the-art LWFA. Subsets of an LWFA electron energy distribution were propagated through the treatment head elements (presuming an existing design for an x-ray production target and flattening filter) implemented within the EGSnrc Monte Carlo code. Three x-ray energy configurations (6 MV, 10 MV and 18 MV) were studied, and the energy width ΔE of the electron-beam subsets varied from 0.5 MeV to 12.5 MeV. As ΔE increased from 0.5 MeV to 4.5 MeV, we found that the off-axis and central-axis dose profiles for x-rays were minimally affected (to within about 3%), a result slightly different from prior calculations of electron beams broadened by scattering foils. For ΔE of the order of 12 MeV, the effect on the off-axis profile was of the order of 10%, but the central-axis depth dose was affected by less than 2% for depths in excess of about 5 cm beyond d max . Although increasing ΔE beyond 6.5 MeV increased the dose rate at d max by more than 10 times, the absolute dose rates were about 3 orders of magnitude below those observed for LWFA-based electron beams at comparable energies. For a practical LWFA-based x-ray device, the beam current must be increased by about 4-5 orders of magnitude. (note)

  16. Dosimetric evaluation of an ipsilateral intensity modulated radiotherapy beam arrangement for parotid malignancies

    International Nuclear Information System (INIS)

    Yirmibesoglu, Eda; Fried, David V.; Kostich, Mark; Rosenman, Julian; Shockley, William; Weissler, Mark; Zanation, Adam; Chera, Bhishamjit

    2013-01-01

    We conducted a dosimetric comparison of an ipsilateral beam arrangement for intensity modulated radiotherapy (IMRT) with off-axis beams. Six patients who received post-operative radiotherapy (RT) for parotid malignancies were used in this dosimetric study. Four treatment plans were created for each CT data set (24 plans): 1) ipsilateral 4-field off-axis IMRT (4fld-OA), 2) conventional wedge pair (WP), 3) 7 field co-planar IMRT (7fld), and 4) ipsilateral co-planar 4-field quartet IMRT (4fld-CP). Dose, volume statistics for the planning target volumes (PTVs) and planning risk volumes (PRVs) were compared for the four treatment techniques. Wedge pair plans inadequately covered the deep aspect of the PTV. The 7-field IMRT plans delivered the largest low dose volumes to normal tissues. Mean dose to the contralateral parotid was highest for 7 field IMRT. Mean dose to the contralateral submandibular gland was highest for 7 field IMRT and WP. 7 field IMRT plans had the highest dose to the oral cavity. The mean doses to the brainstem, spinal cord, ipsilateral temporal lobe, cerrebellum and ipsilateral cochlea were similar among the four techniques. For postoperative treatment of the parotid bed, 4-field ipsilateral IMRT techniques provided excellent coverage while maximally sparing the contralateral parotid gland and submandibular gland

  17. Boosting runtime-performance of photon pencil beam algorithms for radiotherapy treatment planning.

    Science.gov (United States)

    Siggel, M; Ziegenhein, P; Nill, S; Oelfke, U

    2012-10-01

    Pencil beam algorithms are still considered as standard photon dose calculation methods in Radiotherapy treatment planning for many clinical applications. Despite their established role in radiotherapy planning their performance and clinical applicability has to be continuously adapted to evolving complex treatment techniques such as adaptive radiation therapy (ART). We herewith report on a new highly efficient version of a well-established pencil beam convolution algorithm which relies purely on measured input data. A method was developed that improves raytracing efficiency by exploiting the capability of modern CPU architecture for a runtime reduction. Since most of the current desktop computers provide more than one calculation unit we used symmetric multiprocessing extensively to parallelize the workload and thus decreasing the algorithmic runtime. To maximize the advantage of code parallelization, we present two implementation strategies - one for the dose calculation in inverse planning software, and one for traditional forward planning. As a result, we could achieve on a 16-core personal computer with AMD processors a superlinear speedup factor of approx. 18 for calculating the dose distribution of typical forward IMRT treatment plans. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. The use of electron beams for pasteurization of meats

    International Nuclear Information System (INIS)

    Prestwich, K.R.; Kaye, R.J.; Turman, B.N.; Neau, E.L.

    1994-01-01

    Electron beam accelerators can be used for electronic pasteurization of meat products by: (1) using the electrons directly impacting the products, or (2) optimizing the conversion of electron energy to x-rays and treating the product with these x-rays. The choice of process depends on the configuration of the product when it is treated. For electron treatment, ten million electron volt (MeV) kinetic energy is the maximum allowed by international agreement. The depth of penetration of electrons with that energy into a product with density of meat is about five centimeters (cm). Two-sided treatment can be done on products up to 10 cm thick with a two-to-one ratio between minimum and maximum dose. Ground beef patties are about 1.25 cm (0.5 inch thick). Beams with 2.5 MeV electron energy could be used to treat these products. Our calculations show that maximum to minimum dose ratios less than 1.2 can be achieved with this energy if the transverse beam energy is small. If the product thickness is greater than 10 cm, x-rays can provide the needed dose uniformity. Uniform doses can be supplied for pallets with dimensions greater than 1.2 m on each side using x-rays from a 5 MeV electron beam. The efficiency of converting the electron beam to x-rays and configurations to achieve dose uniformity are discussed

  19. The use of electron beams for pasteurization of meats

    Energy Technology Data Exchange (ETDEWEB)

    Prestwich, K.R.; Kaye, R.J.; Turman, B.N.; Neau, E.L.

    1994-12-01

    Electron beam accelerators can be used for electronic pasteurization of meat products by: (1) using the electrons directly impacting the products, or (2) optimizing the conversion of electron energy to x-rays and treating the product with these x-rays. The choice of process depends on the configuration of the product when it is treated. For electron treatment, ten million electron volt (MeV) kinetic energy is the maximum allowed by international agreement. The depth of penetration of electrons with that energy into a product with density of meat is about five centimeters (cm). Two-sided treatment can be done on products up to 10 cm thick with a two-to-one ratio between minimum and maximum dose. Ground beef patties are about 1.25 cm (0.5 inch thick). Beams with 2.5 MeV electron energy could be used to treat these products. Our calculations show that maximum to minimum dose ratios less than 1.2 can be achieved with this energy if the transverse beam energy is small. If the product thickness is greater than 10 cm, x-rays can provide the needed dose uniformity. Uniform doses can be supplied for pallets with dimensions greater than 1.2 m on each side using x-rays from a 5 MeV electron beam. The efficiency of converting the electron beam to x-rays and configurations to achieve dose uniformity are discussed.

  20. External beam radiotherapy for subretinal neovascularization in age-related macular degeneration: is this treatment efficient?

    International Nuclear Information System (INIS)

    Staar, Susanne; Krott, Ralf; Mueller, Rolf-Peter; Bartz-Schmidt, Karl U.; Heimann, Klaus

    1999-01-01

    Purpose: Control of the natural course of sub retinal neovascularization (SRNV) in age-related macular degeneration (AMD) is difficult. Only a subset of patients is suitable for laser coagulation. This prospective study aimed to determine the efficacy and individual benefit of external beam radiotherapy (EBRT). Methods and Materials: The prospective trial included 287 patients with subfoveal neovascularization due to AMD which was verified by fluorescein angiography. Patients have been treated between January 1996 and October 1997. All patients received a total dose of 16 Gy in 2-Gy daily fractions with 5-6 MeV photons based on computerized treatment planning in individual head mask fixation. This first analysis is based on 73 patients (50 women, 23 men, median age 74.3 years), with a median follow-up of 13.3 months and a minimum follow-up of 11 months. Results: All patients completed therapy and tolerability was good. First clinical control with second angiography was performed 6 weeks after irradiation, then in 3-month intervals. Eighteen patients with SRNV refusing radiotherapy served as a control group and were matched with 18 irradiated patients. After 7 months median visual acuity (VA) was 20/160 for the irradiated and 20/400 for the untreated patients. One year after radiotherapy final median VA was 20/400 in both groups. Conclusion: These results suggest that 16 Gy of conventionally fractionated external beam irradiation slows down the visual loss in exudative AMD for only a few months. Patients' reading vision could not be saved for a long-term run

  1. Design of electron beam accelerator for microwave application

    Science.gov (United States)

    Prestwich, K. R.

    Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx 1 microsec) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. Alternatively, a low voltage PFN followed by a highly coupled transformer can be used. Basic design principles for all of the above subsystems are discussed. Both PFLs and PFNs can also be operated as inductive storage systems with opening switches.

  2. Optimisation of 12 MeV electron beam simulation using variance reduction technique

    Science.gov (United States)

    Jayamani, J.; Termizi, N. A. S. Mohd; Kamarulzaman, F. N. Mohd; Aziz, M. Z. Abdul

    2017-05-01

    Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 107 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 107 to 20 × 107. In this study, 5 MeV electron cut-off with 10 × 107 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy.

  3. Optimisation of 12 MeV electron beam simulation using variance reduction technique

    International Nuclear Information System (INIS)

    Jayamani, J; Aziz, M Z Abdul; Termizi, N A S Mohd; Kamarulzaman, F N Mohd

    2017-01-01

    Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 10 7 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 10 7 to 20 × 10 7 . In this study, 5 MeV electron cut-off with 10 × 10 7 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy. (paper)

  4. Production of a helium beam in a focused ion beam machine using an electron beam ion trap

    International Nuclear Information System (INIS)

    Ullmann, F.; Grossmann, F.; Ovsyannikov, V. P.; Gierak, J.; Zschornack, G.

    2007-01-01

    Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range

  5. Electron gun for a multiple beam klystron with magnetic compression of the electron beams

    Science.gov (United States)

    Ives, R. Lawrence; Tran, Hien T; Bui, Thuc; Attarian, Adam; Tallis, William; David, John; Forstall, Virginia; Andujar, Cynthia; Blach, Noah T; Brown, David B; Gadson, Sean E; Kiley, Erin M; Read, Michael

    2013-10-01

    A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.

  6. Risk factors for radiotherapy incidents and impact of an online electronic reporting system

    International Nuclear Information System (INIS)

    Chang, David W.; Cheetham, Lynn; Marvelde, Luc te; Bressel, Mathias; Kron, Tomas; Gill, Suki; Tai, Keen Hun; Ball, David; Rose, William; Silva, Linas; Foroudi, Farshad

    2014-01-01

    Background and purpose: To ascertain the rate, type, significance, trends and the potential risk factors associated with radiotherapy incidents in a large academic department. Materials and methods: Data for all radiotherapy activities from July 2001 to January 2011 were reviewed from radiotherapy incident reporting forms. Patient and treatment data were obtained from the radiotherapy record and verification database (MOSAIQ) and the patient database (HOSPRO). Logistic regression analyses were performed to determine variables associated with radiotherapy incidents. Results: In that time, 65,376 courses of radiotherapy were delivered with a reported incident rate of 2.64 per 100 courses. The rate of incidents per course increased (1.96 per 100 courses to 3.52 per 100 courses, p < 0.001) whereas the proportion of reported incidents resulting in >5% deviation in dose (10.50 to 2.75%, p < 0.001) had decreased after the introduction of an online electronic reporting system. The following variables were associated with an increased rate of incidents: afternoon treatment time, paediatric patients, males, inpatients, palliative plans, head-and-neck, skin, sarcoma and haematological malignancies. In general, complex plans were associated with higher incidence rates. Conclusion: Radiotherapy incidents were infrequent and most did not result in significant dose deviation. A number of risk factors were identified and these could be used to highlight high-risk cases in the future. Introduction of an online electronic reporting system resulted in a significant increase in the number of incidents being reported

  7. Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

    Science.gov (United States)

    Scisciò, M.; Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Papaphilippou, Y.; Antici, P.

    2016-03-01

    In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

  8. Double deflection system for an electron beam device

    International Nuclear Information System (INIS)

    Parker, N.W.; Crewe, A.V.

    1978-01-01

    A double deflection scanning system for electron beam instruments is provided embodying a means of correcting isotropic coma, and anisotropic coma aberrations induced by the magnetic lens of such an instrument. The scanning system deflects the beam prior to entry into the magnetic lens from the normal on-axis intersection of the beam with the lens according to predetermined formulas and thereby reduces the aberrations

  9. Electron Beam Size Measurements in a Cooling Solenoid

    CERN Document Server

    Kroc, Thomas K; Burov, Alexey; Seletsky, Sergey; Shemyakin, Alexander V

    2005-01-01

    The Fermilab Electron Cooling Project requires a straight trajectory and constant beam size to provide effective cooling of the antiprotons in the Recycler. A measurement system was developed using movable appertures and steering bumps to measure the beam size in a 20 m long, nearly continuous, solenoid. This paper discusses the required beam parameters, the implimentation of the measurement system and results for our application.

  10. Structured electron beams from nano-engineered cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Lueangaramwong, A. [NICADD, DeKalb; Mihalcea, D. [NICADD, DeKalb; Andonian, G. [RadiaBeam Tech.; Piot, P. [Fermilab

    2017-03-07

    The ability to engineer cathodes at the nano-scale have open new possibilities such as enhancing quantum eciency via surface-plasmon excitation, forming ultra-low-emittance beams, or producing structured electron beams. In this paper we present numerical investigations of the beam dynamics associated to this class of cathode in the weak- and strong-field regimes.We finally discuss the possible applications of some of the achievable cathode patterns when coupled with other phase space manipulations.

  11. A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams.

    Science.gov (United States)

    Forde, Elizabeth; Booth, Jeremy; Leech, Michelle

    2014-01-01

    The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam׳s central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  12. Electron acoustic solitary waves in a magnetized plasma with nonthermal electrons and an electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Singh, S. V., E-mail: satyavir@iigs.iigm.res.in; Lakhina, G. S., E-mail: lakhina@iigs.iigm.res.in [Indian Institute of Geomagnetism, New Panvel (W), Navi Mumbai (India); University of the Western Cape, Belville (South Africa); Devanandhan, S., E-mail: devanandhan@gmail.com [Indian Institute of Geomagnetism, New Panvel (W), Navi Mumbai (India); Bharuthram, R., E-mail: rbharuthram@uwc.ac.za [University of the Western Cape, Belville (South Africa)

    2016-08-15

    A theoretical investigation is carried out to study the obliquely propagating electron acoustic solitary waves having nonthermal hot electrons, cold and beam electrons, and ions in a magnetized plasma. We have employed reductive perturbation theory to derive the Korteweg-de-Vries-Zakharov-Kuznetsov (KdV-ZK) equation describing the nonlinear evolution of these waves. The two-dimensional plane wave solution of KdV-ZK equation is analyzed to study the effects of nonthermal and beam electrons on the characteristics of the solitons. Theoretical results predict negative potential solitary structures. We emphasize that the inclusion of finite temperature effects reduces the soliton amplitudes and the width of the solitons increases by an increase in the obliquity of the wave propagation. The numerical analysis is presented for the parameters corresponding to the observations of “burst a” event by Viking satellite on the auroral field lines.

  13. Instability during bunch shortening of an electron-cooled beam

    Directory of Open Access Journals (Sweden)

    M. Takanaka

    2003-10-01

    Full Text Available Bunch shortening causes an electron-cooled beam to be space charge dominated at low energies. Instability during the bunch shortening has been studied using a particle-tracking program where the 3D space-charge field due to the beam is calculated with a simplifying model.

  14. Electron beam induced conductivity in 'PET' and 'FEP'

    International Nuclear Information System (INIS)

    Walzade, S.J.; Jog, J.P.; Dake, S.B.; Bhoraskar, S.V.

    1983-01-01

    Electron Beam Induced Conductivity (EBIC), classified into EBIC (bulk) and EBIC (surface) have been measured in PET and FEP respectively. The peculiar oscillatory nature of the induced gain versus beam energy variations is explained in terms of the spatial distributions of the trapping centres near the surface of the polymers. (author)

  15. Improvements in or relating to electron beam deflection arrangements

    International Nuclear Information System (INIS)

    Bull, E.W.

    1979-01-01

    This relates to the deflection of ribbon-like electron beams in X-ray tubes particularly in radiographic equipment. The X-ray tubes includes a source of a ribbon-shaped beam of electrons relatively narrow in a direction orthogonal to the direction of the beam and relatively wide in a second orthogonal direction. An elongated target projects X-rays about a chosen direction in response to the incident beam. There is a means (toroidal former, deflection coils or plates) for deflecting the electron beam to scan the region of incidence along the target and correction means for changing the shape of the electron beam depending on the deflection so that the region of incidence of the deflected beam remains a linear region substantially parallel to the region of incidence of the undeflected beam. The apparatus for this, and variations, are described. A medical radiography unit (computerise axial tomography) including the X-ray tube described is also detailed. (U.K.)

  16. Noninteracting beams of ballistic two-dimensional electrons

    International Nuclear Information System (INIS)

    Spector, J.; Stormer, H.L.; Baldwin, K.W.; Pfeiffer, L.N.; West, K.W.

    1991-01-01

    We demonstrate that two beams of two-dimensional ballistic electrons in a GaAs-AlGaAs heterostructure can penetrate each other with negligible mutual interaction analogous to the penetration of two optical beams. This allows electrical signal channels to intersect in the same plane with negligible crosstalk between the channels

  17. Pulsed hollow cathode discharge: intense electron beam and filamentary plasma

    International Nuclear Information System (INIS)

    Modreanu, Gabriel

    1998-01-01

    This work deals with a transient hollow cathode discharge optimised by a preionization one and providing intense electron beams. It exists a preionization current value for which the pulsed discharge becomes a very straight and bright filament, well collimated on the discharge tube axis for some tenths of centimeters. A remarkable feature of this discharge is that, without internal metallic electrodes very pure plasma could be produced. Using self-biasing by the beam of a Faraday cup placed only few millimeters behind the anode, we deduced the beam electron's distribution function and its temporal behavior for two radial positions, on the axis and 1 millimeter off-axis, respectively. The real advantage of this measurement technique is the transient polarization character, which allows analysis very closely from the electron beam extraction hole. On the other side, using the emission spectroscopy, we have studied the plasma produced in electron beam - gas interaction and deduced the temporal evolution of the electron temperature. The temporal behavior of the filamentary plasma diameter shows a constriction at the last moments of the beam existence, followed by diffusion controlled expansion. The ambipolar diffusion coefficient corresponding to the estimated electron temperature describes quite well this expansion and allows a quantitative interpretation of the measured temperature diminution, with taking into account the preferential fast electrons escape. The analysis of both beam and post-beam plasma phases suggests potential applications of this robust, very reproducible and not expensive discharge also susceptible to be external monitored. The beam - target interaction could be used for PVD, elementary analysis and filamentary or point-like X-ray emission. (author) [fr

  18. Brushless dc motor uses electron beam switching tube as commutator

    Science.gov (United States)

    Studer, P.

    1965-01-01

    Electron beam switching tube eliminates physical contact between rotor and stator in brushless dc motor. The tube and associated circuitry control the output of a dc source to sequentially energize the motor stator windings.

  19. Electron beam irradiated silver nanowires for a highly transparent heater.

    Science.gov (United States)

    Hong, Chan-Hwa; Oh, Seung Kyu; Kim, Tae Kyoung; Cha, Yu-Jung; Kwak, Joon Seop; Shin, Jae-Heon; Ju, Byeong-Kwon; Cheong, Woo-Seok

    2015-12-07

    Transparent heaters have attracted increasing attention for their usefulness in vehicle windows, outdoor displays, and periscopes. We present high performance transparent heaters based on Ag nanowires with electron beam irradiation. We obtained an Ag-nanowire thin film with 48 ohm/sq of sheet resistance and 88.8% (substrate included) transmittance at 550 nm after electron beam irradiation for 120 sec. We demonstrate that the electron beam creates nano-soldering at the junctions of the Ag nanowires, which produces lower sheet resistance and improved adhesion of the Ag nanowires. We fabricated a transparent heater with Ag nanowires after electron beam irradiation, and obtained a temperature of 51 °C within 1 min at an applied voltage of 7 V. The presented technique will be useful in a wide range of applications for transparent heaters.

  20. Inductive voltage adder (IVA) for submillimeter radius electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Mazarakis, M.G.; Poukey, J.W.; Maenchen, J.E. [and others

    1996-12-31

    The authors have already demonstrated the utility of inductive voltage adder accelerators for production of small-size electron beams. In this approach, the inductive voltage adder drives a magnetically immersed foilless diode to produce high-energy (10--20 MeV), high-brightness pencil electron beams. This concept was first demonstrated with the successful experiments which converted the linear induction accelerator RADLAC II into an IVA fitted with a small 1-cm radius cathode magnetically immersed foilless diode (RADLAC II/SMILE). They present here first validations of extending this idea to mm-scale electron beams using the SABRE and HERMES-III inductive voltage adders as test beds. The SABRE experiments are already completed and have produced 30-kA, 9-MeV electron beams with envelope diameter of 1.5-mm FWHM. The HERMES-III experiments are currently underway.

  1. Theory of suppression of loss cone instabilities by electron beams

    International Nuclear Information System (INIS)

    Sinha, A.; Sinha, M.

    1981-01-01

    A new mechanism for the suppression of Drift Cyclotron Loss Cone instabilities by electron beams injected along the field lines is given. The mechanism explains some of the recent observations. (author)

  2. 'The future of the electron beam irradiation service business'

    International Nuclear Information System (INIS)

    Yamase, Yutaka

    1998-01-01

    The high energy electron beam has less penetration power in comparison with the gamma ray which has been used from before. However, the dose rate of the electron beam is considerably high in comparison with the gamma ray with more than several thousand times. Therefore, the irradiation of the product can be done in a short time, and there are cheap characteristics further in the irradiation cost as well. And, an electron beam is the technology which is very easy to accept in the country of a nuclear allergy constitution like our country so that it may not use radioactive substance. This time, I'd like to think about the present condition of the electron beam irradiation service business and a future based on the experience of Tsukuba EBcenter until now. (J.P.N.)

  3. Skin dose from radiotherapy X-ray beams: the influence of energy

    International Nuclear Information System (INIS)

    Butson, M.J.; Metcalfe, P.E.; University of Wollongong, Wollongong, NSW; Mathur, J.N.

    1997-01-01

    Skin-sparing properties of megavoltage photon beams are compromised by electron contamination. Higher energy beams do not necessarily produce lower surface and basal cell layer doses due to this electron contamination. For a 5x5 cm field size the surface doses for 6 MVp and 18 M)p X-ray beams are 10% and 7% of their respective maxima. However, at a field size of 40 x 40cm the percentage surface dose is 42% for both 6 MVp and 18 MVp beams. The introduction of beam modifying devices such as block trays can further reduce the skin-sparing advantages of high energy photon beams. Using a 10 mm perspex block tray, the surface doses for 6 MVp and 18 MVp beams with a 5 x 5 cm field size are 10% and 8%, respectively. At 40 x 40cm, surface doses are 61% and 63% for 6 MVp and 18 MVp beams, respectively. This trend is followed at the basal cell layer depth. At a depth of 1 mm, 18 MVp beam doses are always at least 5% smaller than 6 MVp doses for the same depth at all field sizes when normalized to their respective Dmax values. Results have shown that higher energy photon beams produce a negligible reduction of the delivered dose to the basal cell layer (0.1 mm). Only a small increase in skin sparing is seen at the dermal layer (1 mm), which can be negated by the increased exit dose from an opposing field. (authors)

  4. Measurement of power density distribution and beam waist simulation for electron beam

    International Nuclear Information System (INIS)

    Shen, Chunlong; Peng, Yong; Wang, Kehong; Zhou, Qi

    2013-01-01

    The study aims to measure the power density distribution of the electron beam (EB) for further estimating its characteristics. A compact device combining deflection signal controller and current signal acquisition circuit of the EB was built. A software modelling framework was developed to investigate structural parameters of the electron beam. With an iterative algorithm, the functional relationship between the electron beam power and its power density was solved and the corresponding contour map of power density distribution was plotted through isoline tracking approach. The power density distribution of various layers of cross-section beam was reconstructed for beam volume by direct volume rendering technique. The further simulation of beam waist with all-known marching cubes algorithm reveals the evolution of spatial appearance and geometry measurement principle was explained in detail. The study provides an evaluation of promising to replace the traditional idea of EB spatial characteristics. - Highlights: ► We build a framework for measuring power density distribution for electron beam. ► We capture actual electron and build transient spatial power distribution for EB. ► Tracing algorithm of power density contour for cross-section was designed. ► The volume and waist of the beam are reconstructed in 4D mode. ► Geometry measurement is finished which is befit for designing of process welding.

  5. The use of electron beam in RIA R and D

    International Nuclear Information System (INIS)

    Gomes, Itacil C.; Nolen, Jerry; Reed, Claude

    2004-01-01

    This paper discusses two electron beam applications for the RIA (Rare Isotope Accelerator) R and D. The first is for simulating energy deposition of heavy ions on lithium jets. The peak energy deposition for a 400-kW uranium beam will be 4 MW/cm 3 . Calculations have shown that a 1-MeV electron beam with 40mA of current has a peak energy deposition about 4 MW/cm 3 making it suitable to mimic the thermal response of lithium jet at that uranium beam heat load. The second application of electron beams for RIA R and D, discussed in this paper, is the use of low energy electron beam as a diagnosis tool for on-line monitoring of thickness variations of thin foils or thin jets. Thin foils can be corroded and jets might experience instabilities that can compromise their functionality. Low energy electron beams can be used to detect any change in thickness enabling a continuous on-line monitoring of the thin film being monitored. Calculations have indicated that variations in lithium jet thicknesses at the micron level can easily be detected

  6. Fabrication of Nano-pit Array Using Electron Beam Lithography

    International Nuclear Information System (INIS)

    Maryam Alsadat Rad; Kamarulazizi Ibrahim

    2011-01-01

    This work reports the fabrication of nano-pits array pattern using electron beam lithography (EBL). We investigated the effect of different electron beam dosage and acceleration voltage in fabrication nano-pits array pattern and effect of them on dimension of nano-pits. The SEM images have shown effect of the voltage and dosage variation on them and also the proximity effect. (author)

  7. Dose-volume histogram evaluation of prone and supine patient position in external beam radiotherapy for cervical and endometrial cancer

    International Nuclear Information System (INIS)

    Pinkawa, Michael; Gagel, Bernd; Demirel, Cengiz; Schmachtenberg, Axel; Asadpour, Branka; Eble, Michael J.

    2003-01-01

    Background and purpose: To evaluate the influence of patient positioning on dose-volume histograms of organs at risk in external beam radiotherapy for cervical and endometrial cancer. Materials and methods: In 20 patients scheduled for definitive (7) or postoperative (13) external beam radiotherapy of the pelvis treatment planning CT scans were performed in supine and prone (belly board) positions. After volume definition of target and organs at risk treatment plans were calculated applying the four-field box technique. The dose-volume histograms of organs at risk were compared. Results: Radiotherapy in prone position causes a reduction of the bladder portion (mean 15%, p<0.001) and an increase of the rectum portion (mean 11%, p<0.001) within the 90% isodose. A reduction of the bowel portion could only be observed in postoperatively treated patients (mean 13%, p<0.001). In definitive radiotherapy the target volume increases in supine position (mean 7%, p=0.02) due to an anterior tumour/uterus movement, so that bowel portions within the 90% isodose are similar. The bladder filling correlates with a reduction of bladder and bowel (postoperatively treated patients) dose. Conclusions: External beam radiotherapy of the pelvis should be performed in prone position in postoperative patients because of best bowel protection. Considering the additional HDR brachytherapy rectum protection takes the highest priority in definitive treatment--the requirements are best met in supine position. An adequate bladder filling is important to reduce the irradiated bladder and bowel volumes

  8. Design of automatic tracking system for electron beam welding

    International Nuclear Information System (INIS)

    He Chengdan; Chinese Academy of Space Technology, Lanzhou; Li Heqi; Li Chunxu; Ying Lei; Luo Yan

    2004-01-01

    The design and experimental process of an automatic tracking system applied to local vacuum electron beam welding are dealt with in this paper. When the annular parts of an exactitude apparatus were welded, the centre of rotation of the electron gun and the centre of the annular weld are usually not superposed because of the machining error, workpiece's setting error and so on. In this teaching process, a little bundle of electron beam is used to scan the weld groove, the amount of the secondary electrons reflected from the workpiece is different when the electron beam scans the both sides and the centre of the weld groove. The difference can indicate the position of the weld and then a computer will record the deviation between the electron beam spot and the centre of the weld groove. The computer will analyze the data and put the data into the storage software. During the welding process, the computer will modify the position of the electron gun based on the deviation to make the electron beam spot centered on the annular weld groove. (authors)

  9. Time dependence of microsecond intense electron beam transport in gases

    International Nuclear Information System (INIS)

    Lucey, R.F. Jr.; Gilgenback, R.M.; Tucker, J.E.; Brake, M.L.; Enloe, C.L.; Repetti, T.E.

    1987-01-01

    The authors present results of long-pulse (0.5 μs) electron beam propagation in the ion focused regime (IFR). Electron beam parameters are 800 kV with several hundred amperes injected current. For injection into air (from 0.7 mTorr to 75 mTorr) and helium (from 14 mTorr to 227 mTorr) the authors observe a ''time-dependent propagation window'' in which efficient (up to 100%) propagation starts at a time comparable to the electron impact ionization time needed to achieve n/sub i/ -- (1/γ/sup 2/)n/sub eb/. The transport goes abruptly to zero about 50-150 ns after this initial propagation. This is followed by erratic propagation often consisting of numerous narrower pulses 10-40 ns wide. In these pulses the transported current can be 100% of the injected current, but is generally lower. As the fill pressure is increased, there are differences in the propagated beam pulse, which can be summarized as follows: 1) the temporal occurrence of the beam propagation window shifts to earlier times, 2) the propagated beam current has much faster risetimes, 3) a larger portion of the injected beam is propagated. Similar results are observed when the electron beam is propagated in helium. However, at a given pressure, the beam transport window occurs at later times and exhibits a slower risetime. These effects are consistent with electron beam-induced ionization. Experiments are being performed to determine if the observed beam instability is due to the ion hose instability or streaming instability

  10. Molecule-by-Molecule Writing Using a Focused Electron Beam

    DEFF Research Database (Denmark)

    Van Dorp, Willem F.; Zhang, Xiaoyan; Feringa, Ben L.

    2012-01-01

    atoms also be written with an electron beam? We verify this with focused electron-beam-induced deposition (FEBID), a direct-write technique that has the current record for the smallest feature written by (electron) optical lithography. We show that the deposition of an organometallic precursor...... on graphene can be followed molecule-by-molecule with FEBID. The results show that mechanisms that are inherent to the process inhibit a further increase in control over the process. Hence, our results present the resolution limit of (electron) optical lithography techniques. The writing of isolated...

  11. Sterilization of experimental animal feeds with high energy electron beam

    International Nuclear Information System (INIS)

    Takekawa, Tetsuya; Shakudo, Taketomi; Furuta, Masakazu; Tada, Mikiro

    2005-01-01

    Penetration range and depth-dose distribution of 10 MeV electrons within commercial packages of experimental animal feeds were examined with a high power electron accelerator for verification of the application of high energy electron beam irradiation to sterilize experimental animal feeds. Optimum packaging sizes were proposed based on the experimental results. The change of the vitamins and the efficacy of the sterilization by the irradiation were also studied. It is confirmed that the sterilization of experimental animal feeds by 10 MeV electron beam has been completely practical. (author)

  12. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  13. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-21

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.

  14. Production of large-area plasmas by electron beams

    Science.gov (United States)

    Fernsler, R. F.; Manheimer, W. M.; Meger, R. A.; Mathew, J.; Murphy, D. P.; Pechacek, R. E.; Gregor, J. A.

    1998-05-01

    An analysis is presented for the production of weakly ionized plasmas by electron beams, with an emphasis on the production of broad, planar plasmas capable of reflecting X-band microwaves. Considered first in the analysis is the ability of weakly ionized plasmas to absorb, emit and reflect electromagnetic radiation. Following that is a determination of the electron beam parameters needed to produce plasmas, based on considerations of beam ionization, range, and stability. The results of the analysis are then compared with a series of experiments performed using a sheet electron beam to produce plasmas up to 0.6 m square by 2 cm thick. The electron beam in the experiments was generated using a long hollow-cathode discharge operating in an enhanced-glow mode. That mode has only recently been recognized, and a brief analysis of it is given for completeness. The conclusion of the study is that electron beams can produce large-area, planar plasmas with high efficiency, minimal gas heating, low electron temperature, high uniformity, and high microwave reflectivity, as compared with plasmas produced by other sources.

  15. The model of beam-plasma discharge in the rocket environment during an electron beam injection in the ionosphere

    International Nuclear Information System (INIS)

    Mishin, E.V.; Ruzhin, Yu.Ya.

    1980-01-01

    The model of beam-plasma discharge in the rocket environment during electron beam injection in the ionosphere is constructed. The discharge plasma density dependence on the neutral gas concentration and the beam parameters is found

  16. Beam size measurement of the stored electron beam at the APS storage ring using pinhole optics

    International Nuclear Information System (INIS)

    Cai, Z.; Lai, B.; Yun, W.

    1995-01-01

    Beam sizes of the stored electron beam at the APS storage ring were measured using pinhole optics and bending magnet x-rays in single-bunch and low-current mode. A pinhole of 25 μm and a fast x-ray imaging system were located 23.8 m and 35.4 m from the source, respectively. The x-ray imaging system consists of a CdWO 4 scintillation crystal 60 μm thick, an optical imaging system, and a CCD detector. A measurement time of a few tenths of a second was obtained on a photon beam of E>30 keV produced in a bending magnet from a 7-GeV electron beam of 2mA current. The measured vertical and horizontal sizes of the electron beam were in reasonable agreement with the expected values

  17. [Follow-up study of clinical effects of californium-252 neutron intracavitary radiotherapy and external beam radiotherapy in endometrial cancer].

    Science.gov (United States)

    Lei, Xin; Shan, Jin-lu; Tang, Cheng; Zhao, Ke-wei

    2007-11-01

    To observe the three year local control rate, overall survival rate, complications and prognostic factors of endometrial cancer treated with (252)Cf neutron intracavitary brachytherapy (ICBT) and external beam radiotherapy (EBRT). Forty endometrial cancer patients staged Ib - IVa by the standard of Federation of International Gynecologic Organization (FIGO), who had not received any treatment were enrolled in this study. Treatment schedules were: (252)Cf ICBT, 10 - 13 Gy(i)/fraction per week, the total dose to point A and point F 35 - 45 Gy(i) and 38 - 50 Gy(i) respectively in 4 fractions. The EBRT was given to the whole pelvic field, with 6 MV or 8 MV X-ray, 2 Gy per fraction, 4 times per week. The total dose was 45 to 50 Gy (the field was blocked 4 cm after 20 - 30 Gy), the total treatment time was 5 - 6 weeks. The follow-up time was 36 - 96 months, with an average of 42 months. The three year local control and overall survival rate was 88% (35/40) and 75% (30/40) respectively for all patients. Of those patients of stage Ib, they were 93% (14/15) and 87% (13/15), respectively, higher than stage II [80% (12/15), 87% (13/15); P > 0.05], significantly higher than stage III, IV [60% (6/10), 50% (5/10); P 252)Cf ICBT and EBRT may be safe and effective for advanced endometrial cancer. The most important prognostic factors were stage, pathological type and differentiation of endometrial cancer.

  18. Angular-momentum-dominated electron beams and flat-beam generation

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yin-e [Univ. of Chicago, IL (United States)

    2005-06-01

    In the absence of external forces, if the dynamics within an electron beam is dominated by its angular momentum rather than other effects such as random thermal motion or self Coulomb-repulsive force (i.e., space-charge force), the beam is said to be angular-momentum-dominated. Such a beam can be directly applied to the field of electron-cooling of heavy ions; or it can be manipulated into an electron beam with large transverse emittance ratio, i.e., a flat beam. A flat beam is of interest for high-energy electron-positron colliders or accelerator-based light sources. An angular-momentum-dominated beam is generated at the Fermilab/NICADD photoinjector Laboratory (FNPL) and is accelerated to an energy of 16 MeV. The properties of such a beam is investigated systematically in experiment. The experimental results are in very good agreement with analytical expectations and simulation results. This lays a good foundation for the transformation of an angular-momentum-dominated beam into a flat beam. The round-to-flat beam transformer is composed of three skew quadrupoles. Based on a good knowledge of the angular-momentum-dominated beam, the quadrupoles are set to the proper strengths in order to apply a total torque which removes the angular momentum, resulting in a flat beam. For bunch charge around 0.5 nC, an emittance ratio of 100 ± 5 was measured, with the smaller normalized root-mean-square emittance around 0.4 mm-mrad. Effects limiting the flat-beam emittance ratio are investigated, such as the chromatic effects in the round-to-flat beam transformer, asymmetry in the initial angular-momentum-dominated beam, and space-charge effects. The most important limiting factor turns out to be the uncorrelated emittance growth caused by space charge when the beam energy is low, for example, in the rf gun area. As a result of such emittance growth prior to the round-to-flat beam transformer, the emittance ratio achievable in simulation decreases from orders of thousands to

  19. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields

    International Nuclear Information System (INIS)

    Pavon, Ester Carrasco; Sanchez-Doblado, Francisco; Leal, Antonio; Capote, Roberto; Lagares, Juan Ignacio; Perucha, Maria; Arrans, Rafael

    2003-01-01

    Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm 2 electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm 2 field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm 2 open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R 50 , R 80 , R 100 , R p , E 0 ) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD = 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13deg at SSD 100 cm to more than 30deg at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC

  20. Development of picosecond pulsed electron beam monitor. 2

    International Nuclear Information System (INIS)

    Hosono, Y.; Nakazawa, M.; Ueda, T.

    1994-01-01

    A picosecond pulsed electron beam monitor for a 35 MeV linear accelerator has been developed. The monitor consists of an electric SMA connector and aluminium pipe(inner diameter of 50mm). The following characteristics of this monitor were obtained, (a) the rise time is less than 17.5 ps (b) linearity of the monitor output voltage is proportional to the peak current of beam. It is shown that this monitor can be successfully used for bunch measurements of picosecond pulsed electron beam of 35 MeV linac. (author)

  1. Electron temperature effects for an ion beam source

    International Nuclear Information System (INIS)

    Uramoto, Joshin.

    1979-05-01

    A hydrogen high temperature plasma up to 200 eV is produced by acceleration of electrons in a hot hollow cathode discharge and is used as an ion beam source. Then, two characteristics are observed: A rate of the atomic ion (H + ) number increases above 70%. A perveance of the ion beam increases above 30 times compared with that of a cold plasma, while a floating potential of an ion acceleration electrode approaches an ion acceleration potential (- 500 V) according as an increment of the electron temperature. Moreover, a neutralized ion beam can be produced by only the negative floating electrode without an external power supply. (author)

  2. Radiation degradation of marine polysaccharides by low energy electron beam

    International Nuclear Information System (INIS)

    Yoshii, Fumio; Nagasawa, Naotsugu; Kume, Tamikazu

    2003-01-01

    The radiation degradations of marine polysaccharides by both gamma Co-60 and electron beam irradiations are investigated. Polysaccharides and oligosaccharides can be produced by degradation of corresponding polysaccharides including marine polysaccharides such as alginates, chitin chitosan and carrageenan. The viscosity of alginate, chitosan and carrageenan solution decreases markedly with increase of the low energy electron beam irradiation time and the beam current. Furthermore, the viscosity is reduced sharply in short time for polysaccharide solution with low concentration, for instance carrageenan solution of 1%. (author)

  3. Note: Characteristic beam parameter for the line electron gun.

    Science.gov (United States)

    Iqbal, M; Islam, G U; Zhou, Z; Chi, Y

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm(2) at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm(2)), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  4. On the limiting stationary currents of relativistic electron beams

    International Nuclear Information System (INIS)

    Kavchuk, V.N.; Kondratenko, A.N.

    1987-01-01

    The problem on electron beam transport in the system of different configurations both vacuum and filled with gas or plasma is connected with the problem of the limiting current, which can conduct such systems. Two models of a vacuum relativistic electron beam (REB) are considered. It is shown that there is upper limit for the value of the external magnetic field, H 0 , in the model of isovelocity REB with the constant longitudinal beam particle rate, β z =const. Estimation of the limiting current of REB as a series of inverse power H 0 is obtained. Estimations of the limiting current of magnetized hallow REB with thin walls are obtained in another model with β z ≠ const. Determination used in this case of the limiting current is directly connected with ''trapping'' of the beam central part due to formation of a virtual cathode and based on consideration of uniflux electron motion in the beam. Such an approach allows to obtain estimations of the limiting current of the thin-wall hallow beam. In this case an upper limit for the thickness of the beam wall is connected with the bottom limit for the value of the external magnetic field providing radial beam equilibrium

  5. Generation of Low-Energy High-Current Electron Beams in Plasma-Anode Electron Guns

    Science.gov (United States)

    Ozur, G. E.; Proskurovsky, D. I.

    2018-01-01

    This paper is a review of studies on the generation of low-energy high-current electron beams in electron guns with a plasma anode and an explosive-emission cathode. The problems related to the initiation of explosive electron emission under plasma and the formation and transport of high-current electron beams in plasma-filled systems are discussed consecutively. Considerable attention is given to the nonstationary effects that occur in the space charge layers of plasma. Emphasis is also placed on the problem of providing a uniform energy density distribution over the beam cross section, which is of critical importance in using electron beams of this type for surface treatment of materials. Examples of facilities based on low-energy high-current electron beam sources are presented and their applications in materials science and practice are discussed.

  6. Electron Lens as Beam-Beam Wire Compensator in HL-LHC

    CERN Document Server

    Valishev, A

    2013-01-01

    Current wires are considered for compensation of long-range beam-beam interactions for the High Luminosity upgrade (HL-LHC) of the Large Hadron Collider at CERN. In this note, we demonstrate the advantage of using Electron Lens for this purpose instead of a conventional current-bearing wire.

  7. B-dot monitor for intense electron beam measurement

    International Nuclear Information System (INIS)

    Li Qin; Li Hong; Chen Nan; Gao Feng; Wang Yongwei; Wang Liping

    2009-01-01

    Azimuthal arrays of B-dot loops are often used to measure the time-resolved beam centroid position of a pulsed, intense electron beam propagating in a metallic tube. This paper describes the designing principle, parameters and calibration of the B-dot monitors. According to the beam current pulse rise time, fall time and the pulse width, the B-dot is designed to work as a differential loop, the loop inductance is about 60 nH. The B-dot monitor's sensitivity and the displacement curve are calibrated in the test stand. The sensitivity of the B-dots and the passive RC integrator is averagely 4 147 A/V, integrate constant is about 1 μs. The B-dot monitors are used to measure the Dragon-I electron beam and the experimental results show that the B-dot monitors can measure the beam current and centroid position accurately. (authors)

  8. Generation of helical electron beams by a nonadiabatic gun

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1996-01-01

    The design of a non-adiabatic gun to produce a 10A, 50kV hollow laminar electron beam for gyrotron applications is reported. The beam is extracted from the emitting ring in a direction parallel to the axial guide magnetic field and then propagates across the radial electric field in the anode gap. The electrons are thereby given a transverse velocity upon passing through the modulation anode region where an electrostatic pumping mechanism takes place, so that a considerable amount of the electron energy is converted to transverse kinetic energy. Such a beam extraction method gives rise to favourable features that are examined throughout the work. The dynamics of hollow electron beams with gyromotion propagating down a cylindrical drift tube are also analysed. Due to the action of the beam's self-space charge field, the transverse velocity spread has an oscillatory behaviour along the drift tube wherein the spatial automodulation period shortens with increasing current. Numerical simulation results indicate that even at a 10A beam current, the resulting transverse velocity spread is still less than the spread for a zero beam current. (UK)

  9. Electron and ion beam transport to fusion targets

    International Nuclear Information System (INIS)

    Freeman, J.R.; Baker, L.; Miller, P.A.; Mix, L.P.; Olsen, J.N.; Poukey, J.W.; Wright, T.P.

    1979-01-01

    ICF reactors have been proposed which incorporate a gas-filled chamber to reduce x-ray and debris loading of the first wall. Focused beams of either electrons or ions must be transported efficiently for 2-4 m to a centrally located fusion target. Laser-initiated current-carrying plasma discharge channels provide the guiding magnetic field and the charge- and current-neutralizing medium required for beam propagation. Computational studies of plasma channel formation in air using a 1-D MHD model with multigroup radiation diffusion have provided a good comparison with the expansions velocity and time dependent refractivity profile determined by holographic interferometry. Trajectory calculations have identified a beam expansion mechanism which combines with the usual ohmic dissipation to reduce somewhat the transported beam fluence for electrons. Additional trajectory calculations have been performed for both electrons and light ions to predict the limits on the particle current density which can be delivered to a central target by overlapping the many independently-generated beams. Critical features of the use of plasma channels for transport and overlap of charged particle beams are being tested experimentally with up to twelve electron beams from the Proto II accelerator

  10. An Electron Beam Profile Instrument Based on FBGs

    Directory of Open Access Journals (Sweden)

    Dan Sporea

    2014-08-01

    Full Text Available Along with the dose rate and the total irradiation dose measurements, the knowledge of the beam localization and the beam profile/energy distribution in the beam are parameters of interest for charged particle accelerator installations when they are used in scientific investigations, industrial applications or medical treatments. The transverse profile of the beam, its position, its centroid location, and its focus or flatness depend on the instrument operating conditions or on the beam exit setup. Proof-of-concept of a new type of charged particle beam diagnostics based on fiber Bragg gratings (FBGs was demonstrated. Its operating principle relies on the measurement of the peak wavelength changes for an array of FBG sensors as function of the temperature following the exposure to an electron beam. Periodically, the sensor irradiation is stopped and the FBG are force cooled to a reference temperature with which the temperature influencing each sensor during beam exposure is compared. Commercially available FBGs, and FBGs written in radiation resistant optical fibers, were tested under electron beam irradiation in order to study their possible use in this application.

  11. Study of national dosimetric standards for external beam radiotherapy: application to conformal irradiations

    International Nuclear Information System (INIS)

    Le Roy, M.

    2011-01-01

    The development of new treatment modalities such as IMRT and stereotactic radiotherapy has led to an increasing use of complex fields composed of small beams with multiple incidence angles. These new treatment conditions are very far from classical reference conditions on which international dosimetry protocols are based. In this work, we propose to realize dosimetric standards for radiation fields smaller than the standard 10 * 10 cm 2 field, namely 4 * 4 and 2 * 2 cm 2 . The calibration coefficients of an ionization chamber in terms of absorbed dose to water for these radiation fields were compared in the 6 MV (with and without flattening filter) and 12 MV beams of LNHB medical linac. The references were established from a graphite calorimetry measurement. A graphite calorimeter of small sensitive volume was built specifically for the 2 * 2 cm 2 field. In addition, an ionization chamber suitable to this field size was looked for. We showed that, for the studied beams, the reference chamber's calibration coefficient is independent of the radiation field size between 10 * 10 and 2 * 2 cm 2 , within uncertainties (about 0.4 % at one standard deviation). (author) [fr

  12. Dose determination in radiotherapy for photon beams modified by static intensity modulators

    International Nuclear Information System (INIS)

    Castellanos Lopez, M.E.

    1998-01-01

    The static intensity modulators, used in radiotherapy, modify the spectral composition of the beam and lead to specific problems of the dose calculation. The aim of this work was to establish a three dimensional calculation, global and accurate, adapted to the primary-diffused separation algorithm and valid for any static modulator type. A theoretical study, experimentally verified, allowed the evaluation of the primary fluence, resulting from metallic sheets placed between photons beams of 6 to 23 MV nominal energy. It has been showed that the diffused, coming from the modulators, could be neglected for weak thickness and for the relative dose variation. In return it leads to significant variations of many % on the absolute dose and must be take into account for the bigger thicknesses. Corrective methods for the primary fluence have been proposed. From the energy spectra of the beam, the metallic modulator influence has been studied on the primary and diffused components of the dose and improvements of the calculation method have been proposed. These improvements are based on the modulator representation as a transmission matrix and on semi-empirical corrective factors. (A.L.B.)

  13. A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams

    Energy Technology Data Exchange (ETDEWEB)

    Forde, Elizabeth, E-mail: eforde@tcd.ie [Discipline of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin (Ireland); Booth, Jeremy [Northern Sydney Cancer Centre, Royal North Shore Hospital, New South Wales (Australia); Leech, Michelle [Discipline of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin (Ireland)

    2014-07-01

    The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam's central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued.

  14. An alternative approach to compensators design for photon beams used in radiotherapy

    International Nuclear Information System (INIS)

    Jurkovic, S.; Zauhar, G.; Bistrovic, M.; Faj, D.; Kaliman, Z.; Smilovic Radojcic, D.

    2007-01-01

    The use of compensators in order to achieve desired dose distribution has a long history and is a well-established technique in radiation therapy planning. There are several different calculation methods for determining a compensator's thickness. An alternative method that is based on the Cunningham's modification of Clarkson's method to calculate scattered radiation in beams with an inhomogeneous cross-section is proposed. It is well known that the total dose distribution of radiotherapy photon beam consists of the contributions of the primary beam, attenuated by the tissue layer, and the scattered radiation generated by the primary radiation in single and multiple photon scatter events. The scattered component can be represented as a function of the primary radiation. The central point of our method is the numerical estimation of the primary distribution required to achieve the desired total distribution. Now using the calculated primary distribution, the shape of the modulator could be determined. In this way the contribution of the scattered component is validated in a more accurate way than using effective attenuation coefficients, which is a common practice. The method is verified in various clinical situations and compared with the standard method. The accuracy, although dependent on geometry, was improved by at least 2%. With more complex geometries there is an even higher gain in accuracy with our method when compared to the standard method

  15. Adaptive-Predictive Organ Localization Using Cone-Beam Computed Tomography for Improved Accuracy in External Beam Radiotherapy for Bladder Cancer

    International Nuclear Information System (INIS)

    Lalondrelle, Susan; Huddart, Robert; Warren-Oseni, Karole; Hansen, Vibeke Nordmark; McNair, Helen; Thomas, Karen; Dearnaley, David; Horwich, Alan; Khoo, Vincent

    2011-01-01

    Purpose: To examine patterns of bladder wall motion during high-dose hypofractionated bladder radiotherapy and to validate a novel adaptive planning method, A-POLO, to prevent subsequent geographic miss. Methods and Materials: Patterns of individual bladder filling were obtained with repeat computed tomography planning scans at 0, 15, and 30 minutes after voiding. A series of patient-specific plans corresponding to these time-displacement points was created. Pretreatment cone-beam computed tomography was performed before each fraction and assessed retrospectively for adaptive intervention. In fractions that would have required intervention, the most appropriate plan was chosen from the patient's 'library,' and the resulting target coverage was reassessed with repeat cone-beam computed tomography. Results: A large variation in patterns of bladder filling and interfraction displacement was seen. During radiotherapy, predominant translations occurred cranially (maximum 2.5 cm) and anteriorly (maximum 1.75 cm). No apparent explanation was found for this variation using pretreatment patient factors. A need for adaptive planning was demonstrated by 51% of fractions, and 73% of fractions would have been delivered correctly using A-POLO. The adaptive strategy improved target coverage and was able to account for intrafraction motion also. Conclusions: Bladder volume variation will result in geographic miss in a high proportion of delivered bladder radiotherapy treatments. The A-POLO strategy can be used to correct for this and can be implemented from the first fraction of radiotherapy; thus, it is particularly suited to hypofractionated bladder radiotherapy regimens.

  16. Safety Aspects of EPS-3000 Electron Beam Machine

    International Nuclear Information System (INIS)

    Siti Aiasah Hashim; Shari Jahar; Ayub Muhamad; Sarada Idris

    2011-01-01

    The EPS-3000 electron beam machine was installed and commission in 1991 at the Alurtron Electron Beam Irradiation Centre. It is utilized as a tool to enhance finished products through electron beam irradiation. The machine and its auxiliary systems were built with highest safety in mind due to the possible dangers that it can cause during the irradiation activities. Automatic stops may be activated via various interlocks to protect the integrity of the machine. This type of interlocks are controlled by the set upper and lower limits, mostly related to the machine high voltage (and beam) generation and cooling systems. Radiation safety is also taken care of by provision of shielding and area monitoring. Other potential hazards include ozone poisoning and electromagnetic field (EMF) could be generated by the high voltage. This paper describes the safety and security systems installed within the facility as measures to protect the workers and general public from radiation and other physical threats. (author)

  17. A Compact Beam Source for Free Electron Lasers

    Science.gov (United States)

    Wang, Mingchang; Xu, Zhizhan; Yu, Jinhui; Lee, Byung Cheol; Lee, Jongmin

    2000-10-01

    A compact beam source produced by pseudospark discharge for free electron lasers is developed. An impedance match between a Marx generator and a pseudospark discharge chamber is analyzed, the impedance characteristic curve for the pseudospark discharge chamber is measured for the first time. The configuration of the new device is described, it has a length of one meter; the original pulse line accelerator has total length of 6 meters. A voltage of 300 kV, a current of 4 kA for the compact device is measured. The electron beam has a diameter of 1.5 mm and has self-pinch effect. The beam has a brightness of 10^12 A/(m rad)^2, as same as a brightness from photo-cathode. The compact beam source can be used for free electron lasers and high power switch.

  18. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  19. Dosimetric properties characterization of silicon diodes used in photon beam radiotherapy

    International Nuclear Information System (INIS)

    Bizetto, Cesar Augusto

    2013-01-01

    In the current work it was studied the performance of epitaxial (EPI) and float zone (FZ) silicon diodes as on-line dosimeters for megavoltage (EPI diode) and orthovoltage (EPI and FZ diode) photon beam radiotherapy. In order to be used as dosimeters the diodes were enclosed in black polymethylmethacrylate (PMMA) probes. The devices were then connected, on photovoltaic mode, to an electrometer Keithley® 6517B to allow measurements of the photocurrent. The irradiations were performed with 6 and 18 MV photon beams (Siemens Primus® linear accelerator), 6 and 15 MV (Novalis TX®) and 10, 25, 30 and 50 kV of a Pantak / Seifert X ray radiation device. During the measurements with the Siemens Primus the diodes were held between PMMA plates placed at 10.0 cm depth. When using Novalis TX® the devices were held between solid water plates placed at 50 cm depth. In both cases the diodes were centered in a radiation field of 10 x 10 cm 2 , with the source-to-surface distance (SSD) kept at 100 cm. In measurements with orthovoltage photon beams the diodes were placed 50.0 cm from the tube in a radiation field of 8 cm diameter. The dose-rate dependency was studied for 6 and 15 MV (varying the dose-rate from 100 to 600 monitor units per minute) and for the 50 kV beam by varying the current tube from 2 to 20 mA. All devices showed linear response with dose rate and, within uncertainties the charge collected is independent of dose rate. The current signals induced showed good instantaneous repeatability of the diodes, characterized by coefficients of variation of current (CV) smaller than 1.14% (megavoltage beams) and 0.15% for orthovoltage beams and coefficients of variation of charge (CV) smaller than 1.84% (megavoltage beams) and 1.67% (orthovoltage beams). The dose response curves were quite linear with linear correlation coefficients better than 0.9999 for all diodes. (author)

  20. PEPPo: Using a Polarized Electron Beam to Produce Polarized Positrons

    Energy Technology Data Exchange (ETDEWEB)

    Adeyemi, Adeleke H. [Hampton Univ., Hampton, VA (United States); et al.

    2015-09-01

    Polarized positron beams have been identified as either an essential or a significant ingredient for the experimental program of both the present and next generation of lepton accelerators (JLab, Super KEK B, ILC, CLIC). An experiment demonstrating a new method for producing polarized positrons has been performed at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. The PEPPo (Polarized Electrons for Polarized Positrons) concept relies on the production of polarized e⁻/e⁺ pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. PEPPo demonstrated the effective transfer of spin-polarization of an 8.2 MeV/c polarized (P~85%) electron beam to positrons produced in varying thickness tungsten production targets, and collected and measured in the range of 3.1 to 6.2 MeV/c. In comparison to other methods this technique reveals a new pathway for producing either high-energy or thermal polarized positron beams using a relatively low polarized electron beam energy (~10MeV) .This presentation will describe the PEPPo concept, the motivations of the experiment and high positron polarization achieved.

  1. Electron beam hardening type copper plate printing ink

    International Nuclear Information System (INIS)

    Kawamura, Eiji; Inoue, Mitsuo; Kusaki, Satoichiro

    1989-01-01

    Copper plate printing is the printing method of filling ink in the parts of concave printing elements on a type area, and transferring the ink to a base, and it is the feature that the ink in the printing element parts of a print rises. Copper plate prints show profound feeling, in addition, its effect of preventing forgery is high. This method is generally called engraving printing, and is used frequently for printing various bills and artistic prints. The electron beam irradiation apparatus installed in the laboratory of the Printing Bureau, Ministry of Finance, is an experimental machine of area beam type, and is so constructed as to do batch conveyance and web conveyance. As the ink in printing element parts rises, the offset at the delivery part of a printing machine becomes a problem. Electron beam is superior in its transparency, and can dry instantaneously to the inside of opaque ink. At 200 kV of acceleration voltage, the ink of copper plate prints can be hardened by electron beam irradiation. The dilution monomers as the vehicle for ink were tested for their dilution capability and the effect of electron beam hardening. The problem in the utilization of electron beam is the deterioration of papers, and the counter-measures were tested. (K.I.)

  2. Determination of absorbed dose calibration factors for therapy level electron beam ionization chambers.

    Science.gov (United States)

    McEwen, M R; Williams, A J; DuSautoy, A R

    2001-03-01

    Over several years the National Physical Laboratory (NPL) has been developing an absorbed dose calibration service for electron beam radiotherapy. To test this service, a number of trial calibrations of therapy level electron beam ionization chambers have been carried out during the last 3 years. These trials involved 17 UK radiotherapy centres supplying a total of 46 chambers of the NACP, Markus, Roos and Farmer types. Calibration factors were derived from the primary standard calorimeter at seven energies in the range 4 to 19 MeV with an estimated uncertainty of +/-1.5% at the 95% confidence level. Investigations were also carried out into chamber perturbation, polarity effects, ion recombination and repeatability of the calibration process. The instruments were returned to the radiotherapy centres for measurements to be carried out comparing the NPL direct calibration with the 1996 IPEMB air kerma based Code of Practice. It was found that, in general, all chambers of a particular type showed the same energy response. However, it was found that polarity and recombination corrections were quite variable for Markus chambers-differences in the polarity correction of up to 1% were seen. Perturbation corrections were obtained and were found to agree well with the standard data used in the IPEMB Code. The results of the comparison between the NPL calibration and IPEMB Code show agreement between the two methods at the +/-1% level for the NACP and Farmer chambers, but there is a significant difference for the Markus chambers of around 2%. This difference between chamber types is most likely to be due to the design of the Markus chamber.

  3. Patterns of Failure and Local Control After Intraoperative Electron Boost Radiotherapy to the Presacral Space in Combination with Total Mesorectal Excision in Patients with Locally Advanced Rectal Cancer

    International Nuclear Information System (INIS)

    Roeder, Falk; Treiber, Martina; Oertel, Susanne; Dinkel, Julien; Timke, Carmen; Funk, Angela; Garcia-Huttenlocher, Helena; Bischof, Marc; Weitz, Juergen; Harms, Wolfgang; Hensley, Frank W.; Buchler, Markus W.; Debus, Juergen; Krempien, Robert

    2007-01-01

    Purpose: To evaluate local control and patterns of failure in patients treated with intraoperative electron beam radiotherapy (IOERT) after total mesorectal excision (TME), to appraise the effectiveness of intraoperative target definition. Methods and Materials: We analyzed the outcome of 243 patients with rectal cancer treated with IOERT (median dose, 10 Gy) after TME. Eighty-eight patients received neoadjuvant and 122 patients adjuvant external beam radiotherapy (EBRT) (median dose, 41.4 Gy), and in 88% simultaneous chemotherapy was applied. Median follow-up was 59 months. Results: Local failure was observed in 17 patients (7%), resulting in a 5-year local control rate of 92%. Only complete resection and absence of nodal involvement correlated positively with local control. Considering IOERT fields, seven infield recurrences were seen in the presacral space, resulting in a 5-year local control rate of 97%. The remaining local relapses were located as follows: retrovesical/retroprostatic (5), anastomotic site (2), promontorium (1), ileocecal (1), and perineal (1). Conclusion: Intraoperative electron beam radiotherapy as part of a multimodal treatment approach including TME is a highly effective regimen to prevent local failure. The presacral space remains the site of highest risk for local failure, but IOERT can decrease the percentage of relapses in this area

  4. Energy Spread Reduction of Electron Beams Produced via Laser Wake

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, Bradley Bolt [Univ. of California, San Diego, CA (United States)

    2012-01-01

    Laser wakefield acceleration of electrons holds great promise for producing ultra-compact stages of GeV scale, high quality electron beams for applications such as x-ray free electron lasers and high energy colliders. Ultra-high intensity laser pulses can be self-guided by relativistic plasma waves over tens of vacuum diffraction lengths, to give >1 GeV energy in cm-scale low density plasma using ionization-induced injection to inject charge into the wake at low densities. This thesis describes a series of experiments which investigates the physics of LWFA in the self-guided blowout regime. Beginning with high density gas jet experiments the scaling of the LWFA-produced electron beam energy with plasma electron density is found to be in excellent agreement with both phenomenological theory and with 3-D PIC simulations. It is also determined that self-trapping of background electrons into the wake exhibits a threshold as a function of the electron density, and at the densities required to produce electron beams with energies exceeding 1 GeV a different mechanism is required to trap charge into low density wakes. By introducing small concentrations of high-Z gas to the nominal He background the ionization-induced injection mechanism is enabled. Electron trapping is observed at densities as low as 1.3 x 1018 cm-3 in a gas cell target, and 1.45 GeV electrons are demonstrated for the first time from LWFA. This is currently the highest electron energy ever produced from LWFA. The ionization-induced trapping mechanism is also shown to generate quasi-continuous electron beam energies, which is undesirable for accelerator applications. By limiting the region over which ionization-induced trapping occurs, the energy spread of the electron beams can be controlled. The development of a novel two-stage gas cell target provides the capability to tailor the gas composition in the longitudinal direction, and confine the trapping process to occur only in a

  5. Treatment of locally advanced breast carcinoma with high-dose external beam supervoltage radiotherapy

    International Nuclear Information System (INIS)

    Brufman, G.; Weshler, Z.; Prosnitz, L.R.; Fuks, Z.

    1981-01-01

    Between 1960 and 1978, 87 patients with locally advanced Tsub(3-4)Nsub(0-3)M 0 carcinoma of the breast were treated with 5,000 to 8,000 rad of external beam supervoltage radiotherapy. Initial clinical eradication of the tumour was observed in 76 of 87 cases (87%), but the actuarial probability of local control at 5 yr was only 53%. Furthermore, the actuarial probability of disease-free survival was 25% at 5 yr and 13% at 10 yr. Most of the patients eventually succumbed to metastatic breast carcinoma and the actuarial survival at 5 yr was 43% and at 10 yr, 16%. The addition of adjuvant low-dose chemotherapy, given to 13 patients, did not affect the rates of local control, survival or disease-free survival. The most common long-term complication was extensive and deforming radiation-induced fibrosis of the treated breast. The actuarial probability of 10-yr survival without a local recurrence and without severe fibrosis of the treated breast was only 17.5%. The role of adjuvant high-dose chemotherapy in the treatment of locally advanced breast carcinoma and the possible use of improved radiotherapy techniques to achieve a more effective long-term local control and a more desirable cosmetic end result are discussed. (author)

  6. Monte Carlo dose calculation in photon beam radiotherapy: a dosimetric characterization

    International Nuclear Information System (INIS)

    Caccia, B.; Frustagli, G.; Valentini, S.; Petetti, E.; Andenna, C.

    2008-01-01

    Radiotherapy requires improved dose evaluation procedures in order to better exploit novel, high-performance techniques. This is the case with Intensity Modulated Radiation Therapy (IMRT) where high gradients of dose are the result of highly conformed dose releases. Among all the methods for dose calculation, the Monte Carlo approach is considered the best one in terms of accuracy, but it is very time consuming and requires varied and specialised expertise. In the present paper, Monte Carlo beam models have been developed for a Varian Clinac 2100 medical accelerator. A GEANT4-based model and a distributed computing environment on a Beowulf cluster have been used to perform the simulations. The behaviour of the model was investigated with the use of two phantoms. A good agreement was obtained upon comparing the depth dose profiles simulated for both phantoms with experimental measurements. We consider this a first step towards a more complete model capable of accounting for more complex phantoms and irradiation conditions. (author)

  7. Radiotherapy

    International Nuclear Information System (INIS)

    Pistenma, D.A.

    1980-01-01

    The need for radiotherapy research is exemplified by the 100,000 cancer patients who will fail treatment locally and/or regionally annually for the next several years but who would benefit from better local treatment modalities. Theoretically, all of the areas of investigation discussed in this projection paper have the potential to significantly improve local-regional treatment of cancer by radiotherapy alone or in combination with other modalities. In many of the areas of investigation discussed in this paper encouraging results have been obtained in cellular and animal tumor studies and in limited studies in humans as well. In the not too distant future the number of patients who would benefit from better local control may increase by tens of thousands if developments in chemotherapy and/or immunotherapy provide a means to eradicate disseminated microscopic foci of cancer. Thus the efforts to improve local-regional control take on even greater significance

  8. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  9. Upgrade of the electron beam ion trap in Shanghai

    Energy Technology Data Exchange (ETDEWEB)

    Lu, D.; Yang, Y.; Xiao, J.; Shen, Y.; Fu, Y.; Wei, B.; Yao, K.; Hutton, R.; Zou, Y., E-mail: zouym@fudan.edu.cn [The Key Lab of Applied Ion Beam Physics, Ministry of Education, 200433 Shanghai (China); Shanghai EBIT Lab, Institute of Modern Physics, Fudan University, 200433 Shanghai (China)

    2014-09-15

    Over the last few years the Shanghai electron beam ion trap (EBIT) has been successfully redesigned and rebuilt. The original machine, developed under collaboration with the Shanghai Institute of Applied Physics, first produced an electron beam in 2005. It could be tuned with electron energies between 1 and 130 keV and beam current up to 160 mA. After several years of operation, it was found that several modifications for improvements were necessary to reach the goals of better electron optics, higher photon detection, and ion injection efficiencies, and more economical running costs. The upgraded Shanghai-EBIT is made almost entirely from Ti instead of stainless steel and achieves a vacuum of less than 10{sup −10} Torr, which helps to minimize the loss of highly changed ions through charge exchange. Meanwhile, a more compact structure and efficient cryogenic system, and excellent optical alignment have been of satisfactory. The magnetic field in the central trap region can reach up till 4.8 T with a uniformity of 2.77 × 10{sup −4}. So far the upgraded Shanghai-EBIT has been operated up to an electron energy of 151 keV and a beam current of up to 218 mA, although promotion to even higher energy is still in progress. Radiation from ions as highly charged as Xe{sup 53+,} {sup 54+} has been produced and the characterization of current density is estimated from the measured electron beam width.

  10. Film dosimetry of small elongated electron beams for treatment planning

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.

    1989-01-01

    The characteristics of 5, 7, 10, 12, 15, and 18 Mev electron beams for small elongated fields of dimensions L x W (where L=1, 2, 3, 4, 5, and 10 cm; and W=1, 2, 3, 4, 5, and 10 cm) have been studied. Film dosimetry and parallel-plate ion chamber measurements have been used to obtain various dose parameters. Selective results of a series of systematic measurements for central axis depth dose data, uniformity index, field flatness, and relative output factors of small elongated electron beams are reported. The square-root method is employed to predict the beam data of small elongated electron fields from corresponding small square electron fields using film dosimetry. The single parameter area/perimeter radio A/P is used to characterize the relative output factors of elongated electron beams. It is our conclusion that for clinical treatment planning square-root method may be applied with caution in determining the beam characteristics of small elongated electron fields from film dosimetry. The calculated and estimated relative output factors from square-root method and A/P ratio are in good agreement and show agreement to within 1% with the measured film values

  11. Manufacture of polyethylene foam by electron beam cross-linking

    International Nuclear Information System (INIS)

    Tamai, Isamu

    1976-01-01

    The manufacturing process of polyethylene foam, comparison between electron beam cross-linking process and chemical cross-linking process, the electron beam irradiation technique for continuous sheets, the characteristics and uses of polyethylene foam are reviewed. The pore diameter can be controlled by selecting the dose rate, because there is strong relationship between the pore diameter and the dose rate. As the dose if higher, the foam becomes finer. The electron accelerators having large capacity show the lowest cost as the radiation source, and are applicable industrially. If the production capacity exceeds about 200 tons per month, the costs of electron beam irradiation process may be more advantageous than that of chemical process according to the circumstances. It is difficult to obtain the uniform distribution of absorption dose in the direction of thickness. General characteristics of cross-linked polyethylene foam are listed. The special feature of electron beam process is that the degree of cross-linking can be controlled arbitrarily before foaming. The products obtained by the electron beam cross-linking process have finer foams and smoother surfaces than those obtained by the chemical process, because the separation of the decomposition of foaming agents from that of cross-linking agents in the chemical cross-linking is difficult. (Iwakiri, K.)

  12. Dielectronic recombination measurements using the Electron Beam Ion Trap

    International Nuclear Information System (INIS)

    Knapp, D.A.

    1991-01-01

    We have used the Electron Beam Ion Trap at LLNL to study dielectronic recombination in highly charged ions. Our technique is unique because we observe the x-rays from dielectronic recombination at the same time we see x-rays from all other electron-ion interactions. We have recently taken high-resolution, state-selective data that resolves individual resonances

  13. Dynamics of Pierce instability of hot electron beams

    International Nuclear Information System (INIS)

    Ignatov, A.M.; Novikov, V.N.

    1986-01-01

    On the base of a new method of numerical solution of the Vlasov equation evolution of complete function of electron distribution at the injection of hot electron beams into plasma bounded with electrodes is investigated. It is shown that despite the development of electrostatic instabilities in the system the currents can run substantially exceeding the Pierce critical current

  14. Analysis of a High Speed Electron Beam Deflection System

    Czech Academy of Sciences Publication Activity Database

    Zobač, Martin

    2009-01-01

    Roč. 44, 5-6 (2009), s. 59-63 ISSN 0861-4717 Institutional research plan: CEZ:AV0Z20650511 Keywords : electron beam deflection * transfer function * eddy - current * hysteresis * instability Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  15. Preparation of PbSe nanoparticles by electron beam irradiation

    Indian Academy of Sciences (India)

    A novel method has been developed by electron beam irradiation to prepare PbSe nanoparticles. 2 MeV 10mA GJ-2-II electronic accelerator was used as radiation source. Nanocrystalline PbSe was prepared rapidly at room temperature under atmospheric pressure without any kind of toxic reagents. The structure and ...

  16. Atomic physics measurements in an electron beam ion trap

    Science.gov (United States)

    Marrs, R. E.; Beiersdorfer, P.; Bennett, C.; Chen, M. H.; Cowan, T.; Dietrich, D.; Henderson, J. R.; Knapp, D. A.; Osterheld, S.; Schneider, M. B.; Scofield, J. H.; Levine, M. A.

    1989-06-01

    An electron Beam Ion Trap at Lawrence Livermore National Laboratory is being used to produce and trap very-highly-charged ions (q≥70+) for x-ray spectroscopy measurements. Recent measurements of transition energies and electron excitation cross sections for x-ray line emission are summarized.

  17. Simulation of Laser-Compton Cooling of Electron Beams

    OpenAIRE

    Ohgaki, T.

    2000-01-01

    We study a method of laser-Compton cooling of electron beams. Using a Monte Carlo code, we evaluate the effects of the laser-electron interaction for transverse cooling. The optics with and without chromatic correction for the cooling are examined. The laser-Compton cooling for JLC/NLC at E_0=2 GeV is considered.

  18. CERN's web application updates for electron and laser beam technologies

    CERN Document Server

    Sigas, Christos

    2017-01-01

    This report describes the modifications at CERN's web application for electron and laser beam technologies. There are updates at both the front and the back end of the application. New electron and laser machines were added and also old machines were updated. There is also a new feature for printing needed information.

  19. Intercomparison of ionization chambers in standard X-ray beams, at radiotherapy, diagnostic radiology and radioprotection levels

    International Nuclear Information System (INIS)

    Bessa, Ana Carolina Moreira de

    2007-01-01

    Since the calibration of radiation measurement instruments and the knowledge of their major characteristics are very important subjects, several different types of ionization chambers were inter compared in terms of their calibration coefficients and their energy dependence, in radiotherapy, diagnostic radiology and radioprotection standard beams. An intercomparison of radionuclide calibrators for nuclear medicine was performed, using three radionuclides: 67 Ga, 201 Tl and 99m Tc; the results obtained were all within the requirements of the national standard CNEN-NE-3.05. In order to complete the range of radiation qualities of the Calibration Laboratory of IPEN, standard radiation beam qualities, radiation protection and low energy radiation therapy levels, were established, according international recommendations. Three methodologies for the calibration of unsealed ionization chambers in X-ray beams were studied and compared. A set of Victoreen ionization chambers, specially designed for use in laboratorial intercomparisons, was submitted to characterization tests. The performance of these Victoreen ionization chambers showed that they are suitable for use in radioprotection beams, because the results obtained agree with international recommendations. However, these Victoreen ionization chambers can be used in radiotherapy and diagnostic radiology beams only with some considerations, since their performance in these beams, especially in relation to the energy dependence and stabilization time tests, did not agree with the international recommendations for dosimeters used in radiotherapy and diagnostic radiology beams. This work presents data on the performance of several types of ionization chambers in different X-ray beams, that may be useful for choosing the appropriate instrument for measurements in ionizing radiation beams. (author)

  20. Optimisation of electron beam characteristics by simulated annealing

    International Nuclear Information System (INIS)

    Ebert, M.A.; University of Adelaide, SA; Hoban, P.W.

    1996-01-01

    Full text: With the development of technology in the field of treatment beam delivery, the possibility of tailoring radiation beams (via manipulation of the beam's phase space) is foreseeable. This investigation involved evaluating a method for determining the characteristics of pure electron beams which provided dose distributions that best approximated desired distributions. The aim is to determine which degrees of freedom are advantageous and worth pursuing in a clinical setting. A simulated annealing routine was developed to determine optimum electron beam characteristics. A set of beam elements are defined at the surface of a homogeneous water equivalent phantom defining discrete positions and angles of incidence, and electron energies. The optimal weighting of these elements is determined by the (generally approximate) solution to the linear equation, Dw = d, where d represents the dose distribution calculated over the phantom, w the vector of (50 - 2x10 4 ) beam element relative weights, and D a normalised matrix of dose deposition kernels. In the iterative annealing procedure, beam elements are randomly selected and beam weighting distributions are sampled and used to perturb the selected elements. Perturbations are accepted or rejected according to standard simulated annealing criteria. The result (after the algorithm has terminated due to meeting an iteration or optimisation specification) is an approximate solution for the beam weight vector (w) specified by the above equation. This technique has been applied for several sample dose distributions and phase space restrictions. An example is given of the phase space obtained when endeavouring to conform to a rectangular 100% dose region with polyenergetic though normally incident electrons. For regular distributions, intuitive conclusions regarding the benefits of energy/angular manipulation may be made, whereas for complex distributions, variations in intensity over beam elements of varying energy and