WorldWideScience

Sample records for electromobility fast-tracking innovation

  1. Electromobility guide; Wegweiser Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Becks, Thomas; De Doncker, Rik; Karg, Ludwig; Rehtanz, Christian; Reinhardt, Andreas-Michael; Willums, Jan-Olaf [eds.

    2010-07-01

    Knowing about funded projects and their results helps to safeguard own innovation activities, promotes precompetition know-how transfer and makes it easier to use synergetic effects. This is where the new ''Electromobility Guide'' has a contribution to make. It gives the reader basic information on more than 150 national and international projects about electromobility. It names contact partners and gives corresponding details to make it easier to collect additional information. Our intention is for the Electromobility Guide to act as an incentive for sharing current, authentic, correct and reliable information about all electromobility projects in order to expand the joint data basis. Please help us in this respect and support electromobility in Germany with your knowledge. (orig.)

  2. Second report of the national platform electromobility; Zweiter Bericht der Nationalen Plattform Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-05-15

    In the National Platform Electromobility, representatives from industry, science, politics, unions and societies in Germany agreed on a systematic, market-oriented and technology-open approach to become the main supplier and main market for electromobility up to the year 2020. A central component of the targeted German mean market for electromobility is an intelligent energy system: integration of electricity from renewable energy sources, demand-oriented development of a public charging infrastructure, development of an innovative charging structure. The common goal of the National Electromobility Platform is to build a self-supporting market for electric vehicles. The National Electromobility Platform will support the implementation of these intentions and measures. The underlying assumptions are reviewed annually. Derived recommendations are adapted, if necessary. Thus the National Electromobility Platform develops an annual progress report. With the end of the market scheduling phase by 2014, especially the market acceleration, demand for public infrastructure, costs and funding approaches for market acceleration as well as research and development will be re-evaluated.

  3. Second report of the national platform electromobility. Appendix; Zweiter Bericht der Nationalen Plattform Elektromobilitaet. Anhang

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-05-15

    In the National Platform Electromobility, representatives from industry, science, politics, unions and societies in Germany agreed on a systematic, market-oriented and technology-open approach to become the main supplier and main market for electromobility up to the year 2020. Within the appendix of the second report to the National Platform Electromobility the following aspects are considered: (1) Content and criteria for the identification and evaluation of the emphases of flagship projects; (2) Flagship projects of the national conference on education; (3) Review on standardization activities; (4) A consistent design of public charging infrastructure; (5) Saving the distribution and financing of the public charging infrastructure; (6) Costs and payment reserves vehicle; (7) Criteria of tenders and awarding showcase projects; (8) Innovation promotion in Germany for renewable electromobility (I.D.E.E.) - standpoint of the WWF, climate alliance of the local authorities and the federal association renewable energies.

  4. Standardisation roadmap for electromobility; Normungs-Fahrplan fuer die Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Heusinger, Stefan [DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE, Frankfurt/Main (Germany). Bereich Standardisierung

    2011-03-15

    All internal combustion engines - even the most efficient ones - consume fossil fuels which are getting increasingly scarce. The future of power supply, also in the mobile sector, is in renewables and electromobility. In Germany, the NPE (National Platform for Electromobility) was founded in order to achieve standardisation in this field as early as possible. A standardisation roadmap was established which is to facilitate implementation of electromobility during the next few years.

  5. Manual of electromobility; Handbuch Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Korthauer, Reiner [ed.

    2010-07-01

    Classic motor vehicles with gasoline or diesel engines have obtained a negative image as the resources of petroleum and natural gas are being depleted. Further, the current climate debate and more rigid pollutant emission limits for conventional vehicles have initiated a process of reconsideration. Electromobility has become a much-discussed current issue. This manual outlines all relevant aspects of this future-oriented technology from a social, political and technological viewpoint and indicates options and perspectives. Subjects are: 1. Electric vehicles: History, drive components and current exemplary vehicles; 2. The economic situation of the German electrical industry: Better prospects with electromobility? 3. Electromobility: Trends and perspectives; 4. Mobility in the future: Efficient, emission-free and electrical? 5. At the start of a new age of mobility: MobiliTec, the central trade fair for electromobility at the Hanover Fair, enables an exchange of experience between future-oriented industries; 6. In search of allegories of electromobility, electric vehicle design in the eyes of the public; 7. Battery systems for electric and hybrid vehicles; 8. Testing and certification of modern lithium battery systems by the VDE testing and certification institute; 9. The availability of lithium as a raw material; 10. Recycling of key components of future electric vehicles; 11. Industrial jobs for electricians, securing of trainees and expert staff in the field of electromobility. [German] Die klassische Art der Fortbewegung mittels Otto- oder Dieselmotor ist mittlerweile aus mehreren Gruenden negativ belegt. Die endlichen Energieressourcen wie Oel und Gas werden irgendwann nicht mehr unter den heutigen Bedingungen zu gewinnen sein. Die aktuelle Klimadebatte und verschaerfte Grenzwerte der Schadstoffemissionen bei herkoemmlich angetriebenen Fahrzeugen haben einen Prozess des Umdenkens eingeleitet. Elektromobilitaet ist in aller Munde und ein vieldiskutiertes Thema

  6. Fast track-hoftealloplastik

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Gromov, Kirill; Kristensen, Billy B

    2017-01-01

    Fast-track surgery implies a coordinated perioperative approach aimed at reducing surgical stress and facilitating post-operative recovery. The fast-track programme has reduced post-operative length of stay and has led to shorter convalescence with more rapid functional recovery and decreased...... morbidity and mortality in total hip arthroplasty. It should now be a standard total hip arthroplasty patient pathway, but fine tuning of the multiple factors in the fast-track pathway is still needed in patients with special needs or high comorbidity burden....

  7. An innovative strategy to increase a professional workforce: the fast track initiative for health visitors in England.

    Science.gov (United States)

    Sayer, Lynn; Barriball, K Louise; Bliss, Julie; Bakhshi, Savita; While, Alison E

    2016-04-01

    Fast tracking is one strategy that organizations use to ameliorate workforce shortfalls by attracting new recruits, and accelerating their skills development and experience. In response to the Government's target of rapidly expanding the number of health visitors in England's National Health Service, the fast track initiative was launched to recruit newly qualified (fast track) as well as experienced (standard entry) nurses and midwives onto health visiting programmes. This paper evaluates the fast track initiative, from the perspective of fast track and standard entry students, practice teachers and health visitor managers. A mixed methods design was used comprising a questionnaire survey (n = 71 students), semi-structured interviews (n = 37 students), telephone interviews (n = 13 managers) and six focus groups (n = 24 practice teachers). Data were collected between April 2012 and July 2013. Descriptive statistics, t-tests and the Pearson Chi-square test were used to analyse the quantitative data. The qualitative data were analysed thematically. Motivations for health visiting as a career choice were similar for fast track and standard entry students, with career progression and interest in health promotion being key motivators. There was consensus that personal qualities and characteristics were more important than experience or qualifications. However, fast track students were significantly less confident about their public health competencies in leadership and management (p communication (p  0.5). Fast tracking offers a useful recruitment strategy in order to expand the health visitor workforce, but longitudinal research is needed to confirm benefits such as retention and career trajectories. © The Author(s) 2015.

  8. Fast-track totalknæalloplastik

    DEFF Research Database (Denmark)

    Gromov, Kirill; Kristensen, Billy B; Jørgensen, Christoffer Calov

    2017-01-01

    patients are eligible for fast-track TKA, and hence the fast-track concept should be standard at all joint replacement facilities. Future challenges of fast-track TKA include safe introduction of outpatient protocols, acute and chronic pain after surgery and optimal utilization of post......Fast-track total knee arthroplasty (TKA) is a well-established concept including optimized logistics and evidence-based treatment, focusing on minimizing surgical stress and improved post-operative recovery, thus leading to lower mortality and morbidity as well as high patient satisfaction. All...

  9. Dossier electromobility and services; Dossier Elektromobilitaet und Dienstleistungen

    Energy Technology Data Exchange (ETDEWEB)

    Marwede, Max; Knoll, Michael

    2010-07-01

    According to the individual electromobility, the dossier under consideration reports on the political, environmental, economic and technical context within which municipalities may cover new services for sustainable mobility. Among others, measures to promote electromobility in the communities as well as a framework for business models for the electrical mobility are presented. As a business model, Better Place, STAWAG StromSTA {sup registered} Mobile, rolling energy storages and drive current provider are presented.

  10. Percentage of Fast-Track Receipts

    Data.gov (United States)

    Social Security Administration — The dataset provides the percentage of fast-track receipts by state during the reporting fiscal year. Fast-tracked cases consist of those cases identified as Quick...

  11. Nanotechnology for environmentally sustainable electromobility

    Science.gov (United States)

    Ellingsen, Linda Ager-Wick; Hung, Christine Roxanne; Majeau-Bettez, Guillaume; Singh, Bhawna; Chen, Zhongwei; Whittingham, M. Stanley; Strømman, Anders Hammer

    2016-12-01

    Electric vehicles (EVs) powered by lithium-ion batteries (LIBs) or proton exchange membrane hydrogen fuel cells (PEMFCs) offer important potential climate change mitigation effects when combined with clean energy sources. The development of novel nanomaterials may bring about the next wave of technical improvements for LIBs and PEMFCs. If the next generation of EVs is to lead to not only reduced emissions during use but also environmentally sustainable production chains, the research on nanomaterials for LIBs and PEMFCs should be guided by a life-cycle perspective. In this Analysis, we describe an environmental life-cycle screening framework tailored to assess nanomaterials for electromobility. By applying this framework, we offer an early evaluation of the most promising nanomaterials for LIBs and PEMFCs and their potential contributions to the environmental sustainability of EV life cycles. Potential environmental trade-offs and gaps in nanomaterials research are identified to provide guidance for future nanomaterial developments for electromobility.

  12. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... on clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects...... of the hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  13. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery....... Methods 29 patients were operated with 30 revision arthroplasties. Median age was 67 (34-84) years. All patients followed a standardized fast-track set-up designed for primary TKA. We determined the outcome regarding LOS, morbidity, mortality, and satisfaction. Results Median LOS was 2 (1-4) days...

  14. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery...

  15. A Survey on the Reliability of Power Electronics in Electro-Mobility Applications

    DEFF Research Database (Denmark)

    Gadalla, Brwene Salah Abdelkarim; Schaltz, Erik; Blaabjerg, Frede

    2015-01-01

    Reliability is an important issue in the field of power electronics since most of the electrical energy is today processed by power electronics. In most of the electro-mobility applications, e.g. electric and hybridelectric vehicles, power electronic are commonly used in very harsh environment...... and extending the service lifetime as well. Research within power electronics is of high interest as it has an important impact in the industry of the electro-mobility applications. According to the aforementioned explanations, this paper will provide an overview of the common factors (thermal cycles, power...... cycles, vibrations, voltage stress and current ripple stress) affecting the reliability of power electronics in electromobility applications. Also, the researchers perspective is summarized from 2001 to 2015....

  16. Cardiac surgery fast-track treatment in a postanesthetic care unit: six-month results of the Leipzig fast-track concept.

    Science.gov (United States)

    Ender, Joerg; Borger, Michael Andrew; Scholz, Markus; Funkat, Anne-Kathrin; Anwar, Nadeem; Sommer, Marcus; Mohr, Friedrich Wilhelm; Fassl, Jens

    2008-07-01

    The authors compared the safety and efficacy of a newly developed fast-track concept at their center, including implementation of a direct admission postanesthetic care unit, to standard perioperative management. All fast-track patients treated within the first 6 months of implementation of our direct admission postanesthetic care unit were matched via propensity scores and compared with a historical control group of patients who underwent cardiac surgery prior to fast-track implementation. A total of 421 fast-track patients were matched successfully to 421 control patients. The two groups of patients had a similar age (64 +/- 13 vs. 64 +/- 12 yr for fast-track vs. control, P = 0.45) and European System for Cardiac Operative Risk Evaluation-predicted risk of mortality (4.8 +/- 6.1% vs. 4.6 +/- 5.1%, P = 0.97). Fast-track patients had significantly shorter times to extubation (75 min [45-110] vs. 900 min [600-1140]), as well as shorter lengths of stay in the postanesthetic or intensive care unit (4 h [3.0-5] vs. 20 h [16-25]), intermediate care unit (21 h [17-39] vs. 26 h [19-49]), and hospital (10 days [8-12] vs. 11 days [9-14]) (expressed as median and interquartile range, all P operations.

  17. Mobile with renewable energy. Marketable solutions for climate-friendly electromobility; Erneuerbar mobil. Marktfaehige Loesungen fuer eine klimafreundliche Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-03-15

    This publication presents the goals envisioned by the German Federal Environmental Ministry for electromobility, which are outlined by the four keywords clean, gentle, economic, and practical. It then reports on focal areas of state funding and on projects: field trials on electromobility in private automotive traffic; field trials on electromobility in commercial automotive traffic; hybrid busses for environmentally friendly public transport; accompanying scientific research; and battery recycling.

  18. ATLAS FTK: Fast Track Trigger

    CERN Document Server

    Volpi, Guido; The ATLAS collaboration

    2015-01-01

    An overview of the ATLAS Fast Tracker processor is presented, reporting the design of the system, its expected performance, and the integration status. The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge to the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency in interesting events, despite the increase in multiple p-p collisions per bunch crossing (pile-up). In order to increase the use of tracks within the High Level Trigger (HLT), the ATLAS experiment planned the installation of an hardware processor dedicated to tracking: the Fast TracKer (FTK) processor. The FTK is designed to perform full scan track reconstruction at every Level-1 accept. To achieve this goal, the FTK uses a fully parallel architecture, with algorithms designed to exploit the computing power of custom VLSI chips, the Associative Memory, as well as modern FPGAs. The FT...

  19. Aspects of energy economy and energy economy law as regards electromobility. Pt. 1; Eenrgiewirtschaftliche und energiewirtschaftsrechtliche Fragen der Elektromobilitaet. T. 1

    Energy Technology Data Exchange (ETDEWEB)

    Fest, Claus [RWE Effizienz GmbH, Dortmund (Germany). Umfeldmanagement/Stakeholder Management; Franz, Oliver [RWE AG, Essen (Germany). Regulierungsmanagement; Haas, Gabriele [RWE AG, Essen (Germany). Energie- und Regulierungsrecht

    2010-04-15

    The integration of electromobility into an overall concept for the future transport and energy economy is gradually taking on shape. The commitment to electromobility is growing, not only nationally but also at the EU level. However, beside some overriding problems relating to economic policy there are also numerous subordinate issues that are important for the practical implementation of electromobility. Those concerning the energy and network industries have to do with the integration of electromobility into today's market and its process landscape. There are also some unresolved questions of energy law.

  20. Fast-track video-assisted thoracoscopic surgery

    DEFF Research Database (Denmark)

    Holbek, Bo Laksafoss; Petersen, René Horsleben; Kehlet, Henrik

    2016-01-01

    Objectives To provide a short overview of fast-track video-assisted thoracoscopic surgery (VATS) and to identify areas requiring further research. Design A literature search was made using key words including: fast-track, enhanced recovery, video-assisted thoracoscopic surgery, robot......-assisted thoracoscopic surgery (RATS), robotic, thoracotomy, single-incision, uniportal, natural orifice transluminal endoscopic surgery (NOTES), chest tube, air-leak, digital drainage, pain management, analgesia, perioperative management, anaesthesia and non-intubated. References from articles were screened for further...

  1. [Fast-track treatment--second revolution of colorectal surgery].

    Science.gov (United States)

    Kellokumpu, Ilmo

    2012-01-01

    The fast-track treatment model can be regarded as the second revolution of colorectal surgery after the introduction of laparoscopic surgery. In the gastro-surgical unit of the Central Hospital of Central Finland, results equivalent to international studies in colorectal surgery have been achieved by using fast-track model. In a study setting, this treatment model has resulted in significant decrease of total treatment costs and speeded up discharge of the patients from the hospital. The fast-track treatment model requires both a motivated, trained medical team and a motivated patient.

  2. Standardising fast-track surgical nursing care in Denmark

    DEFF Research Database (Denmark)

    Hjort Jakobsen, Dorthe; Rud, Kirsten; Kehlet, Henrik

    2014-01-01

    guidelines based on the principles of fast-track surgery-i.e. patient information, surgical stress reduction, effective analgesia, early mobilisation and rapid return to normal eating. Fast-track surgery was introduced systematically in Denmark by the establishment of the Unit of Perioperative Nursing (UPN...

  3. Delirium after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, L S; Hansen, T B

    2012-01-01

    hospital stay and medical morbidity. No data on PD are available in fast-track surgery. The aim of this study was to evaluate the incidence of PD after fast-track hip (THA) and knee arthroplasty (TKA) with anticipated length of stay (LOS) of In a prospective multicentre study to evaluate postoperative...

  4. E-volution of mobility. Guiding market for electro-mobility; E-volution der Mobilitaet. Leitmarkt fuer Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Monschaw, Hubertus von [Deutsche Messe AG, Hannover (Germany). Abt. Energiethemen Hannover Messe

    2011-03-21

    Germany intends to become the leading market for electromobility during the next ten years. Time is pressing as the competition from the USA and Asia is busy, too. German scientists and motor car industry are working feverishly in various fields of technology. The Hanover Fair accompanies technical trends and fields of tension of electromobility with its Mobiltec fair, to be held on April 4 - 8, 2011.

  5. FAST-TRACK HIP AND KNEE ARTHROPLASTY (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    A. M. Ageenko

    2017-01-01

    Full Text Available In the present paper the authors discuss the history of fast-track formation, its development and current status. Fast-track advantages in comparison to other rehabilitation options are analyzed. The focus is placed on methods of accelerated rehabilitation after total hip and knee arthroplasty in the leading European and American clinics. Fast-track protocols of surgical centers of Denmark and Hospital for special surgery in the US are described, factors that determine time of hospital stay after total hip and knee arthroplasty are considered, predictors of hospital stay and patients satisfaction after the surgery are examined. The paper reflects the results of the comparison of frequency of thromboembolic and other complications as well as readmission rate after traditional rehabilitation and after fast-track. The paper considers fast-track in bilateral total knee replacement. The authors conclude that further research on acceleration of rehabilitation and reduction of hospital stay after total hip and knee arthroplasty needs to be focused on the optimization of pain relief, especially after discharge, blood preservation techniques, supplementation of fluids loss and strengthening of muscles. Literature analysis demonstrated that the implementation of the Protocol for accelerated recovery after joint arthroplasty in Russia is at an insufficient level. Data of foreign multicenter studies during recent years indicate a high efficacy and safety of this technique in different groups of patients.

  6. Fast-Track Teacher Recruitment.

    Science.gov (United States)

    Grant, Franklin Dean

    2001-01-01

    Schools need a Renaissance human-resources director to implement strategic staffing and fast-track teacher-recruitment plans. The HR director must attend to customer satisfaction, candidate supply, web-based recruitment possibilities, stabilization of newly hired staff, retention of veteran staff, utilization of retired employees, and latest…

  7. Fast track pathway for perforated appendicitis.

    Science.gov (United States)

    Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall

    2017-04-01

    Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Fast-Track Management of Patients Undergoing Proximal Pancreatic Resection

    Science.gov (United States)

    French, JJ; Mansfield, SD; Jaques, K; Jaques, BC; Manas, DM; Charnley, RM

    2009-01-01

    INTRODUCTION To avoid the risk of complications of biliary drainage, a feasibility study was carried out to determine whether it might be possible to fast-track surgical treatment, with resection before biliary drainage, in jaundiced patients with proximal pancreatic/peri-ampullary malignancy. PATIENTS AND METHODS Over an 18-month period, based on their presenting bilirubin levels and other logistical factors, all jaundiced patients who might be suitable for fast-track management were identified. Data on complications and hospital stay were compared with those patients in whom a conventional pathway (with biliary drainage) was used during the same time period. Data were also compared with a group of patients from the preceding 6 months. RESULTS Nine patients were fast-tracked and 49 patients treated in the conventional pathway. Fast-track patients mean (SD) serum bilirubin level was 265 μmol/l (81.6) at the time of the operation compared to 43 μmol/l (51.3; P ≥ 0.0001) in conventional patients. Mean (SD) of time from referral to operation, 14 days (9) versus 59 days (36.9), was significantly shorter in fast-track patients than conventional patients (P ≤ 0.0001). Length of hospital stay mean (SD) at 17 (6) days versus 22 days (19.6; P = 0.2114), surgical complications and mortality in fast-track patients were similar to conventional patients. Prior to surgery, the 49 conventional patients underwent a total of 73 biliary drainage procedures resulting in seven major complications. Comparison with the group of patients from the previous 6 months indicated that the conventional group were not disadvantaged. CONCLUSIONS Fast-track management by resection without biliary drainage of selected patients with distal biliary strictures is safe and has the potential to reduce the waiting time to surgery, overall numbers of biliary drainage procedures and the complications thereof. PMID:19220943

  9. Fast tracking in paediatric cardiac anaesthesia : an update.

    Directory of Open Access Journals (Sweden)

    Lake Carol

    2002-01-01

    Full Text Available A care plan in which cardiac surgical patients progress quickly through the perioperative course to hospital discharge is often referred to as a Fast Track. Such care plans have been used extensively in adult cardiac patients but are also applicable to paediatric patients. Although no randomised controlled trials are available to document a reduction in hospital costs and avoidance of iatrogenic complications with paediatric fast tracks, many healthcare administrators encourage their use. Fast Track clinical guidelines usually include same day surgery, use of short- acting anaesthetic drugs, early extubation, effective pain management, and reduced intensive care unit stays. These protocols are certainly appropriate for simple procedures such as repair of atrial or ventricular septal defects or ligation of a patent ductus arteriosus. However, many paediatric cardiac anaesthesiologists consider that all paediatric patients without significant pulmonary or residual cardiac pathology can be managed using expedited postoperative protocols. Essential components in a "fast track" protocol include use of minimally invasive surgical techniques, modified ultrafiltration during cardiopulmonary bypass, transoesophageal echocardiography to evaluate the cardiac repair, and postoperative pain control. Using such techniques, 80-90% of paediatric patients can be extubated in the operating room or within 2-4 hours postoperatively. Despite the opinions of recognised experts, an appropriately sized and powered multicentre, controlled, randomised, prospective study is still needed to conclusively document the efficiency and effectiveness of the Fast Track in paediatric cardiac patients.

  10. Evidence Basis for Regional Anesthesia in Multidisciplinary Fast-Track Surgical Care Pathways

    DEFF Research Database (Denmark)

    Carli, Francesco; Kehlet, Henrik; Baldini, Gabriele

    2011-01-01

    Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type of surge......Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type...... of surgeries. The aim of this article was to identify and discuss potential advantages offerred by regional anesthesia and analgesia techniques to fast-track programs. In the first section, the impact of regional anesthesia on the main elements of fast-track surgery is addressed. In the second section......, procedure-specific fast-track programs for colorectal, hernia, esophageal, cardiac, vascular, and orthopedic surgeries are presented. For each, regional anesthesia and analgesia techniques more frequently used are discussed. Furthermore, clinical studies, which included regional techniques as elements...

  11. Sufentanil Vs Fentanyl for Fast-Track Cardiac Anaesthesia

    Directory of Open Access Journals (Sweden)

    C M Deshpande

    2009-01-01

    Full Text Available A perioperative anaesthetic management that aims to facilitate tracheal extubation of patients within 1-6 hrs after cardiac surgery is called "fast-track′. Main advantage of ′fast-track" method is better usage of medical resources and lowering hospital costs without increasing morbidity and mortality of the patients. Standard fast-track protocols contain short acting anaesthetic agents, smaller incisions and decreased pump times without hypothermia. In this study we compared two short acting opioid drugs, fentanyl versus Sufentanil when used as a part of the balanced anaesthesia technique for fast track in cardiac surgery patients& evaluated the time taken for extubation, haemodynamic stability, analgesia requirements& incidence of awareness. The results from the study show thatboth agents provide good haemodynamic stability and postoperative analgesia. Although Sufentanil provides earlier extuba-tion, both agents reduce the ICU stay equally. In conclusion both agents can be used effectively for fasttrack cardiac anaesthesia.

  12. FTK: a Fast Track Trigger for ATLAS

    International Nuclear Information System (INIS)

    Anderson, J; Auerbach, B; Blair, R; Andreani, A; Andreazza, A; Citterio, M; Annovi, A; Beretta, M; Castegnaro, A; Atkinson, M; Cavaliere, V; Chang, P; Bevacqua, V; Crescioli, F; Blazey, G; Bogdan, M; Boveia, A; Canelli, F; Cheng, Y; Cervigni, F

    2012-01-01

    We describe the design and expected performance of a the Fast Tracker Trigger (FTK) system for the ATLAS detector at the Large Hadron Collider. The FTK is a highly parallel hardware system designed to operate at the Level 1 trigger output rate. It is designed to provide global tracks reconstructed in the inner detector with resolution comparable to the full offline reconstruction as input of the Level 2 trigger processing. The hardware system is based on associative memories for pattern recognition and fast FPGAs for track reconstruction. The FTK is expected to dramatically improve the performance of track based isolation and b-tagging with little to no dependencies of pile-up interactions.

  13. Delirium in the fast-track surgery setting

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, Lars S; Kehlet, Henrik

    2012-01-01

    Postoperative delirium (PD) and postoperative cognitive dysfunction (POCD) are two separate syndromes of cognitive decline after major surgery, especially in the elderly. Pathogenesis is multifactorial with some common risk factors, and to reduce the risk, a multimodal approach is necessary. The ....... In conclusion, the fast-track methodology may reduce the incidence of postoperative cognitive decline after surgery........ The fast-track methodology is becoming a well-established perioperative care regime with possible preventive effects for postoperative cognitive decline, including reduced pain and use of opioids, and early mobilisation with early discharge (≤3 days) to preoperative environment after total hip....../knee arthroplasty (THA/TKA). The fast-track set-up seems to be associated with a lower frequency of PD and early POCD after THA/TKA. Thus, in a series of 225 patients ≥60 years, no cases of PD were seen and the incidence of POCD was reduced by more than 50% at 1 week postoperatively compared to previous studies...

  14. Fast-track knee arthroplasty – status and future challenges

    DEFF Research Database (Denmark)

    Kehlet, Henrik; Thienpont, Emmanuel

    2013-01-01

    Fast-track programs have been developed for different surgical procedures leading to higher patient satisfaction and lower morbidity. This concept has been extended to knee arthroplasty in recent years. The purpose of this narrative review was to discuss the different aspects of fast-track knee...... arthroplasty....

  15. Fast-track surgery: Toward comprehensive peri-operative care.

    Science.gov (United States)

    Nanavati, Aditya J; Prabhakar, S

    2014-01-01

    Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome.

  16. Orchestrating care through the fast-track perspective: A qualitative content analysis of the provision of individualised nursing care in orthopaedic fast-track programmes.

    Science.gov (United States)

    Berthelsen, Connie Bøttcher; Frederiksen, Kirsten

    2017-02-01

    The lack of individualised care in orthopaedic regimes is often explained by the extended use of patient pathways and clinical guidelines. The aim of this study was to illuminate orthopaedic nurses' perceptions and experiences of providing individual nursing care for older patients in standardised fast-track programmes after total hip or knee replacement. Ten semi-structured interviews were conducted with orthopaedic nurses in orthopaedic wards at three Danish hospitals between April and June of 2015. Data were analysed using manifest and latent content analysis according to Graneheim and Lundman. The main theme of the overall interpretation was Orchestrating care through the fast-track perspective, accompanied by three sub-themes: Identifying and legitimising relevant individual care in the fast-track programme, Struggling to fit all patients in the fast-track programme and Justifying individualised care-related actions in the fast-track programme. The study concluded that, even though the nurses struggled to comply with the programme, they still found themselves compromising their nursing care and ethics to follow the standardised regime. There is a need to establish more specific inclusion criteria to maintain the effective elements in the programme and to facilitate nurses' opportunities to offer individual care, thereby ensuring that fragile patients have access to other possibilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Fast-track surgery for breast cancer is possible

    DEFF Research Database (Denmark)

    Mertz, Birgitte G; Kroman, Niels; Williams, Helene

    2013-01-01

    INTRODUCTION: Breast cancer is common among Danish women with more than 4,100 new cases annually. In 2008 the concept of fast-track surgery was introduced at the Department of Breast Surgery at Rigshospitalet, Copenhagen. The aim of this study is to describe the new clinical pathway for breast...... to provide immediate advice and support. CONCLUSION: The results confirm that a short stay can be successfully carried out for breast cancer patients. Implementing the fast-track programme involved the introduction of a clear clinical pathway for the patients and more effective daily routines. Patients felt...... cancer patients after implementation of a fast-track surgery programme. MATERIAL AND METHODS: A clinical pathway of all involved disciplines was developed including anaesthetic, analgesics, nausea and vomiting, drain and wound management, discharge assessment and psychosocial support. RESULTS...

  18. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    DEFF Research Database (Denmark)

    Burgdorf, Stefan K; Rosenberg, Jacob

    2012-01-01

    Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks...... care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic...... in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we aimed to reduce hospitalisation without increasing cost in nursing staff per hospital bed. Length of stay...

  19. Fast-track Orthognathic Surgery: An Evidence-based Review

    Science.gov (United States)

    Otero, Joel Joshi; Detriche, Olivier; Mommaerts, Maurice Yves

    2017-01-01

    The aim of this study was to establish a fast-track protocol for bimaxillary orthognathic surgery (OGS). Fast-track surgery (FTS) is a multidisciplinary approach where the pre-, intra-, and postoperative management is focusing maximally on a quick patient recovery and early discharge. To enable this, the patients’ presurgical stress and postsurgical discomfort should be maximally reduced. Both referral patterns and expenses within the health-care system are positively influenced by FTS. University hospital-literature review through Medline, Embase, and the Cochrane Library (January 2000–July 2016) using the following words – “fast track, enhanced recovery, multimodal, and perioperative care” – to define a protocol evidence based for OGS, as well as evidenced-based medicine search of every term added to the protocol during the same period. The process has resulted in an OGS protocol that may improve the outcome of the patient through several nonoperative and operative measures such as preoperative patient education and intra/postoperative measures that should improve overall patient satisfaction, decrease morbidity such as postoperative nausea, headache, dizziness, pain, and intubation discomfort, and shorten hospital stay. A literature review allowed us to fine-tune a fast-track protocol for uncomplicated OGS that can be prospectively studied against currently applied ones. PMID:29264281

  20. Evidence Basis for Regional Anesthesia in Multidisciplinary Fast-Track Surgical Care Pathways

    DEFF Research Database (Denmark)

    Carli, Francesco; Kehlet, Henrik; Baldini, Gabriele

    2011-01-01

    Fast-track programs have been developed with the aim to reduce perioperative surgical stress and facilitate patient's recovery after surgery. Potentially, regional anesthesia and analgesia techniques may offer physiological advantages to support fast-track methodologies in different type...... of surgeries. The aim of this article was to identify and discuss potential advantages offerred by regional anesthesia and analgesia techniques to fast-track programs. In the first section, the impact of regional anesthesia on the main elements of fast-track surgery is addressed. In the second section......, procedure-specific fast-track programs for colorectal, hernia, esophageal, cardiac, vascular, and orthopedic surgeries are presented. For each, regional anesthesia and analgesia techniques more frequently used are discussed. Furthermore, clinical studies, which included regional techniques as elements...

  1. Innovative control systems for tracked vehicle platforms

    CERN Document Server

    2014-01-01

     This book has been motivated by an urgent need for designing and implementation of innovative control algorithms and systems for tracked vehicles. Nowadays the unmanned vehicles are becoming more and more common. Therefore there is a need for innovative mechanical constructions capable of adapting to various applications regardless the ground, air or water/underwater environment. There are multiple various activities connected with tracked vehicles. They can be distributed among three main groups: design and control algorithms, sensoric and vision based in-formation, construction and testing mechanical parts of unmanned vehicles. Scientists and researchers involved in mechanics, control algorithms, image processing, computer vision, data fusion, or IC will find this book useful.

  2. Electromobility - using opportunities through value-generating business models; Elektromobilitaet. Chancen durch wertschoepfende Geschaeftsmodelle nutzen

    Energy Technology Data Exchange (ETDEWEB)

    Timm, Christian; Vierbauch, Christoph [Process Management Consulting GmbH, Muenchen (Germany)

    2011-03-15

    Since press reports on the first electrically powered vehicle covering 600 km without recharge, if not possibly before, discussions about what used to be the bottleneck of electromobility, namely range, have subsided more and more into the background. Now the industry has new challenges to face, in particular the question of how electromobility products should be positioned so as to win the end consumer's interest. According to a recent TUeV survey, 54% of all interviewees are willing to buy an electrically powered vehicle. However, consumers are still put off by the high level of prices, long charging times and the lack of market transparency.

  3. Safety of fast track surgery in pancreaticoduodenectomy: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    LI Weinan

    2017-01-01

    Full Text Available ObjectiveTo investigate the safety and clinical effect of fast track surgery in pancreaticoduodenectomy, one of the most complex surgeries in general surgery. MethodsThe Chinese and foreign databases were searched for articles on the application of fast tract surgery in pancreaticoduodenectomy published from January 1994 to April 2016. Two researchers evaluated the quality of the articles which met the inclusion criteria and extracted related data. Stata 12.0 software was used to analyze the overall incidence rate of complications and the incidence rates of pancreatic leakage and gastrointestinal emptying disorder, and the Begg rank correlation test and Egger linear regression method were used to investigate publication bias. ResultsThe fast track surgery group had a significantly lower overall incidence rate of complications than the conventional group (RR=0.748, 95%CI: 0.680-0.824, P<0.001. There was no significant difference in the incidence rate of pancreatic leakage between the two groups (RR=0.894, 95%CI:0.734-1.089, P=0.266. The fast track surgery group had a significantly lower incidence rate of gastrointestinal emptying disorder than the conventional group (RR=0.520, 95%CI:0.400-0.670, P<0.001. ConclusionFast track surgery is safe and effective in pancreaticoduodenectomy, but the application of some measures in fast track surgery still needs more medical evidence.

  4. Charging stations location model based on spatiotemporal electromobility use patterns

    Science.gov (United States)

    Pagany, Raphaela; Marquardt, Anna; Zink, Roland

    2016-04-01

    One of the major challenges for mainstream adoption of electric vehicles is the provision of infrastructure for charging the batteries of the vehicles. The charging stations must not only be located dense enough to allow users to complete their journeys, but the electric energy must also be provided from renewable sources in order to truly offer a transportation with less CO2 emissions. The examination of potential locations for the charging of electric vehicles can facilitate the adaption of electromobility and the integration of electronic vehicles in everyday life. A geographic information system (GIS) based model for optimal location of charging stations in a small and regional scale is presented. This considers parameters such as the forecast of electric vehicle use penetration, the relevant weight of diverse point of interests and the distance between parking area and destination for different vehicle users. In addition to the spatial scale the temporal modelling of the energy demand at the different charging locations has to be considerate. Depending on different user profiles (commuters, short haul drivers etc.) the frequency of charging vary during the day, the week and the year. In consequence, the spatiotemporal variability is a challenge for a reliable energy supply inside a decentralized renewable energy system. The presented model delivers on the one side the most adequate identified locations for charging stations and on the other side the interaction between energy supply and demand for electromobility under the consideration of temporal aspects. Using ESRI ArcGIS Desktop, first results for the case study region of Lower Bavaria are generated. The aim of the concept is to keep the model transferable to other regions and also open to integrate further and more detailed user profiles, derived from social studies about i.e. the daily behavior and the perception of electromobility in a next step.

  5. Bilateral simultaneous total hip arthroplasty in a fast track setting

    DEFF Research Database (Denmark)

    Otte, Kristian S; Husted, Henrik; Ørsnes, Thue

    2011-01-01

    and low complication rates when performed in a fast-track setting. We believed it would be useful to assess hip arthroplasty in this context, and we report 50 consecutive fast-track simultaneous bilateral hip arthroplasty procedures. The median length of stay was 4 days. Mortality within 90 days was 4......% and 8% required a further operative procedure. The overall complication rate was 22%. 55% of the complications were considered to be caused by failures in surgical technique and 45% by other factors. Bilateral simultaneous hip arthroplasty may have a high complication rate in a fast-track setting...

  6. Care principles at four fast-track arthroplasty departments in Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Solgaard, Søren; Hansen, Torben B

    2010-01-01

    The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery.......The goal of this study was to describe the logistic and clinical set-up at four Danish arthroplasty departments offering fast-track surgery....

  7. Mobility 2.0: Co-Operative ITS Systems for Enhanced Personal Electromobility

    NARCIS (Netherlands)

    Solar, Alma; Bolovinou, Anastasia; Heijenk, Geert; Lasgouttes, Jean-Marc; Giménez, Rafael

    2013-01-01

    Mobility2.0 is an ITS project aiming at developing and testing an in-vehicle commuting assistant for FEV mobility, resulting in more reliable and energy-efficient electro-mobility. In order to achieve a maximum impact, Mobility2.0 takes an integrated approach of addressing the main bottlenecks of

  8. National platform electromobility. Working group 4 - Key issue paper standardization and certification; Nationale Plattform Elektromobilitaet. AG 4 - Eckpunktepapier Normung, Standardisierung und Zertifizierung

    Energy Technology Data Exchange (ETDEWEB)

    Hoelk, Stephanie [Audi AG, Ingolstadt (Germany). I/EM-1

    2010-07-01

    On behalf of the working group 4 ''Standardization and certification ''of the national platform electromobility arranged by the Federal Government, the ''German standardization roadmap electromobility'' was compiled. This gives a survey of the existing structures and definitions of the standardization and designates substantial demands and recommendations for action in order to contribute to the break-through of the electromobility in Europe and in the world. The position paper summarizes the central asking of the standardization roadmap. It identifies necessary basic conditions, appoints concrete recommendations for action and shows the further demand for action for the standardization.

  9. ATLAS FTK Fast Track Trigger

    CERN Document Server

    Iizawa, T; The ATLAS collaboration

    2014-01-01

    The Fast TracKer (FTK) will perform global track reconstruction after each Level-1 trigger accept signal to enable the software-based higher level trigger to have early access to tracking information. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful Field Programmable Gate Arrays (FPGAs) form an important part of the system architecture, and the large level of computing power required for pattern recognition is provided by incorporating standard-cell ASICs named Associative Memory (AM). Motivation and the architecture of the FTK system will be presented, and the status of hardware and simulation will be following.

  10. Nursing care in fast-track surgery strategy

    Directory of Open Access Journals (Sweden)

    Dorota Kozieł

    2015-10-01

    Full Text Available In recent years, many study results have been published confirming an improvement in the outcomes of treatment related with management of patients within the fast-track surgery programme. Early postoperative rehabilitation is possible provided there is engagement of a multi-disciplinary team, including well-educated nurses. Today, a diversion can be observed from traditional nursing on behalf of a coordinated, holistic approach, while more attention is paid to the, thus far marginalised, psychosocial aspects of care. The objective of the study is to discuss the basic assumptions of fast track surgery with respect to nursing care, with particular emphasis placed on the educational function. Modern nursing within the short-track surgery programme should focus on the provision of patients with care consisting of preliminary information concerning the perioperative period, social and psychological support, counselling in the area of home convalescence, and procedures in the case of complications.

  11. Which fast track elements predict early recovery after colon cancer surgery?

    NARCIS (Netherlands)

    Vlug, M. S.; Bartels, S. A. L.; Wind, J.; Ubbink, D. T.; Hollmann, M. W.; Bemelman, W. A.; Sprangers, Mirjam; Preckel, Benedikt; Bossuyt, Patrick; Gouma, Dirk; van Berge Henegouwen, Mark; Fuhring, Jan; Lenthe, Ineke Picard-van; Bakker, Chris; King-Kalimanis, Bellinda; Hofland, Jan; Dejong, Cornelis; van Dam, Ronald; Cuesta, Miguel; van der Peet, Donald; van Zalingen, Edith; Noordhuis, Astrid; de Jong, Dick; Engel, Alexander; Goei, T. Hauwy; de Stoppelaar, Erica; van den Dongen, Marjon; van Wagensveld, Bart; van Tets, Willem; van den Elsen, Maarten; Swart, Annemiek; Gerhards, Michael; de Wit, Laurens; Siepel, Muriel; Molly, Glaresa; Gasthuis, Onze Lieve Vrouwe; van Geloven, Anna; Juttmann, Jan; Clevers, Wilfred; Bieleman, Andrea; van der Zaag, Edwin; Coenen, Ludo; Bonekamp, Elly; Cense, Huib; van Abeelen, Jacobus; van Iterson-de Jong, Diana; Krombeen, Margriet

    2012-01-01

    Aim It is questioned whether all separate fast track elements are essential for enhanced postoperative recovery. We aimed to determine which baseline characteristics and which fast track elements are independent predictors of faster postoperative recovery in patients undergoing resection for colon

  12. National platform electromobility. Working group 4 - Key issue paper standardization and certification; Nationale Plattform Elektromobilitaet. AG 4 - Eckpunktepapier Normung, Standardisierung und Zertifizierung

    Energy Technology Data Exchange (ETDEWEB)

    Hoelk, Stephanie (comp.) [Audi AG, Ingolstadt (Germany). I/EM-1

    2010-07-01

    On behalf of the working group 4 ''Standardization and certification ''of the national platform electromobility arranged by the Federal Government, the ''German standardization roadmap electromobility'' was compiled. This gives a survey of the existing structures and definitions of the standardization and designates substantial demands and recommendations for action in order to contribute to the break-through of the electromobility in Europe and in the world. The position paper summarizes the central asking of the standardization roadmap. It identifies necessary basic conditions, appoints concrete recommendations for action and shows the further demand for action for the standardization.

  13. An artificial retina for fast track finding

    International Nuclear Information System (INIS)

    Ristori, Luciano

    2000-01-01

    A new approach is proposed for fast track finding in position-sensitive detectors. The basic working principle is modeled on what is widely believed to be the low-level mechanism used by the eye to recognize straight edges. A number of receptors are tuned such that each one responds to a different range of track orientations, each track actually fires several receptors and an estimate of the orientation is obtained through interpolation. The feasibility of a practical device based on this principle and its possible implementation using currently available digital logic is discussed

  14. PREDICTING A FAST-TRACK MARITIME CAREER: CHARACTERISTICS OF SUCCESSFUL OFFICERS DURING TEENAGE YEARS

    Directory of Open Access Journals (Sweden)

    Manuel Joaquín Fernández González

    2017-12-01

    Full Text Available Fast-track maritime career is a topical question worldwide due to the shortage of seafarers in maritime industry. Assuming that the fast-track career officers’ relevant common characteristics in adolescence could predict future maritime career speed, the research questions of this research are: What were the common characteristics of fast-track career officers when they were 16-18? Were there any statistically significant differences between the fast-track career groups and the officers with a slower career at that age? A questionnaire survey involving 175 maritime officers was conducted in Latvia in January – October 2016, regarding officers’ family context, school achievement, involvement in sports, and personality traits when they were 16-18. Fast-track career officers perceived themselves as more conscientious, calm and more leadership oriented than the whole group in adolescence. Statistically significant differences among career-speed groups were found regarding family socioeconomic status, family atmosphere and family career support at that age. Based on those communalities among maritime officers with a fast-track carrier when they were 16-18, maritime education and training institutions could better find and give appropriate career guidance to prospective maritime officers. Even if maritime career speed is a very individualized phenomenon, family characteristics could be studied further as a potential good predictor of fast-track maritime career.

  15. An Improved Fast Compressive Tracking Algorithm Based on Online Random Forest Classifier

    Directory of Open Access Journals (Sweden)

    Xiong Jintao

    2016-01-01

    Full Text Available The fast compressive tracking (FCT algorithm is a simple and efficient algorithm, which is proposed in recent years. But, it is difficult to deal with the factors such as occlusion, appearance changes, pose variation, etc in processing. The reasons are that, Firstly, even if the naive Bayes classifier is fast in training, it is not robust concerning the noise. Secondly, the parameters are required to vary with the unique environment for accurate tracking. In this paper, we propose an improved fast compressive tracking algorithm based on online random forest (FCT-ORF for robust visual tracking. Firstly, we combine ideas with the adaptive compressive sensing theory regarding the weighted random projection to exploit both local and discriminative information of the object. The second reason is the online random forest classifier for online tracking which is demonstrated with more robust to the noise adaptively and high computational efficiency. The experimental results show that the algorithm we have proposed has a better performance in the field of occlusion, appearance changes, and pose variation than the fast compressive tracking algorithm’s contribution.

  16. "Fast Track" and "Traditional Path" Coaches: Affordances, Agency and Social Capital

    Science.gov (United States)

    Rynne, Steven

    2014-01-01

    A recent development in large-scale coach accreditation (certification) structures has been the "fast tracking" of former elite athletes. Former elite athletes are often exempted from entry-level qualifications and are generally granted access to fast track courses that are shortened versions of the accreditation courses undertaken by…

  17. Fast-track surgery-an update on physiological care principles to enhance recovery

    DEFF Research Database (Denmark)

    Kehlet, Henrik

    2011-01-01

    INTRODUCTION: The concept of fast-track surgery (enhanced recovery programs) has been evolved and been documented to be successful by decreasing length of stay, morbidity and convalescence across procedures. FUTURE STRATEGIES: However, there are several possibilities for further improvement of mo...... of the components of fast-track surgery, where surgical stress, fluid and pain management are key factors. There is an urgent need for better design of studies, especially in minimal invasive surgery to achieve maximal outcome effects when integrated into the fast-track methodology....

  18. Postoperative morbidity after fast-track laparoscopic resection of rectal cancer

    DEFF Research Database (Denmark)

    Stottmeier, S; Harling, H; Wille-Jørgensen, Peer Anders

    2012-01-01

    Aim: Analysis was carried out of the nature and chronological order of early complications after fast-track laparoscopic rectal surgery with a view to optimize the short-time outcome of rectal cancer surgery. Method: 102 consecutive patients who underwent elective fast-track laparoscopic rectal......: Postoperative morbidity remains a significant problem even in the fast-track era, even in experienced surgical hands. Our results suggest that besides improvement of surgical technique further improvement of outcome lies in early recognition and proper treatment of complications and the perioperative...... cancer surgery were analysed prospectively from the Danish Colorectal Cancer Database supplemented by data from the medical records. We studied in detail the nature and chronological order of postoperative morbidity and reason for prolonged stay (>5 days). Results: Twenty-five patients (25 per cent) had...

  19. Orchestrating care through the fast-track perspective: Orthopaedic nurses’ perceptions and experiences of providing individualised nursing care in older patients’ standardised fast-track programmes after total hip or knee replacement

    DEFF Research Database (Denmark)

    Bøttcher Berthelsen, Connie; Frederiksen, Kirsten

    2017-01-01

    The lack of individualised care in orthopaedic regimes is often explained by the extended use of patient pathways and clinical guidelines. The aim of this study was to illuminate orthopaedic nurses' perceptions and experiences of providing individual nursing care for older patients in standardised...... fast-track programmes after total hip or knee replacement. Ten semi-structured interviews were conducted with orthopaedic nurses in orthopaedic wards at three Danish hospitals between April and June of 2015. Data were analysed using manifest and latent content analysis according to Graneheim...... and Lundman. The main theme of the overall interpretation was Orchestrating care through the fast-track perspective, accompanied by three sub-themes: Identifying and legitimising relevant individual care in the fast-track programme, Struggling to fit all patients in the fast-track programme and Justifying...

  20. TRACKING TESTS FOR THE SNS FAST INJECTION BUMP POWER SUPPLY

    International Nuclear Information System (INIS)

    ENG, W.; CUTLER, R.; DEWAN, S.

    2004-01-01

    The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper

  1. A blueprint for multidisciplinary fast track gastrointestinal oncology care

    NARCIS (Netherlands)

    Basta, Y.L.

    2017-01-01

    In this thesis, we have evaluated the implementation of two key concepts of the Gastro Intestinal oncology Center Amsterdam (GIOCA): multidisciplinary teams (MDT) and the fast delivery of care in fast track clinics (FTC). The first part of this thesis investigates the value of multidisciplinary

  2. Effect of an Emergency Department Fast Track on Press-Ganey Patient Satisfaction Scores

    Directory of Open Access Journals (Sweden)

    Hwang, Calvin E.

    2014-12-01

    Full Text Available Introduction: Mandated patient surveys have become an integral part of Medicare remuneration, putting hundreds of millions of dollars in funding at risk. The Centers for Medicare & Medicaid Services (CMS recently announced a patient experience survey for the emergency department (ED. Development of an ED Fast Track, where lower acuity patients are rapidly seen, has been shown to improve many of the metrics that CMS examines. This is the first study examining if ED Fast Track implementation affects Press-Ganey scores of patient satisfaction. Methods: We analyzed returned Press-Ganey questionnaires from all ESI 4 and 5 patients seen 11AM - 11PM, August-December 2011 (pre-fast track, and during the identical hours of fast track, August-December 2012. Raw ordinal scores were converted to continuous scores for paired student t-test analysis. We calculated an odds ratio with 100% satisfaction considered a positive response. Results: An academic ED with 52,000 annual visits had 140 pre-fast track and 85 fast track respondents. Implementation of a fast track significantly increased patient satisfaction with the following: wait times (68% satisfaction to 88%, OR 4.13, 95% CI [2.32-7.33], doctor courtesy (90% to 95%, OR 1.97, 95% CI [1.04-3.73], nurse courtesy (87% to 95%, OR 2.75, 95% CI [1.46-5.15], pain control (79% to 87%, OR 2.13, 95% CI [1.16-3.92], likelihood to recommend (81% to 90%, OR 2.62, 95% CI [1.42-4.83], staff caring (82% to 91%, OR 2.82, 95% CI [1.54-5.19], and staying informed about delays (66% to 83%, OR 3.00, 95% CI [1.65-5.44]. Conclusion: Implementation of an ED Fast Track more than doubled the odds of significant improvements in Press-Ganey patient satisfaction metrics and may play an important role in improving ED performance on CMS benchmarks. [West J Emerg Med. 2015;16(1:34–38.

  3. Evidence-based surgical care and the evolution of fast-track surgery

    DEFF Research Database (Denmark)

    Kehlet, H.; Wilmore, D.W.

    2008-01-01

    , randomized studies, and meta-analyses, the concept of the "fast-track methodology" has uniformly provided a major enhancement in recovery leading to decreased hospital stay and with an apparent reduction in medical morbidity but unaltered "surgery-specific" morbidity in a variety of procedures. However......BACKGROUND: Optimization of postoperative outcome requires the application of evidence-based principles of care carefully integrated into a multimodal rehabilitation program. OBJECTIVE: To assess, synthesize, and discuss implementation of "fast-track" recovery programs. DATA SOURCES: Medline MBASE...... (January 1966-May 2007) and the Cochrane library (January 1966-May 2007) were searched using the following keywords: fast-track, enhanced recovery, accelerated rehabilitation, and multimodal and perioperative care. In addition, the synthesis on the many specific interventions and organizational...

  4. The Danish Head and Neck Cancer fast-track program

    DEFF Research Database (Denmark)

    Roennegaard, Anders B.; Rosenberg, Tine; Bjørndal, Kristine

    2018-01-01

    -track clinical pathway solutions. Objectives: The objectives of this study were 1) to present the setup of the head and neck cancer (HNC) fast-track program at Odense University Hospital (OUH) as an example of the Danish model and 2) to present patient characteristics, diagnostic outcome, cancer detection rate...

  5. Stimulating Creativity and Innovation through Intelligent Fast Failure

    Science.gov (United States)

    Tahirsylaj, Armend S.

    2012-01-01

    Literature on creativity and innovation has discussed the issue of failure in the light of its benefits and limitations for enhancing human potential in all domains of life, but in business, science, engineering, and industry more specifically. In this paper, the Intelligent Fast Failure (IFF) as a useful tool of creativity and innovation for…

  6. Second Generation of a Fast-track Liver Resection Programme

    DEFF Research Database (Denmark)

    Schultz, Nicolai A; Larsen, Peter N; Klarskov, B

    2018-01-01

    was given to all patients before surgery, catheters and drains were systematically removed early, and patients were mobilized and started eating and drinking from the day of surgery. An opioid-sparing multimodal pain treatment was given for the first week. The discharge criteria were (1) pain sufficiently....... The readmission rate was 6% and the 30-day mortality zero. The LOS decreased compared to our first-generation fast-track programme with LOS 5 days. CONCLUSIONS: Fast-track principles for perioperative care and early discharge are safe even after major liver resection. The introduction of high-dose steroids...

  7. Pathogenesis of morbidity after fast-track laparoscopic colonic cancer surgery

    DEFF Research Database (Denmark)

    Stottmeier, S; Harling, H; Wille-Jørgensen, P

    2011-01-01

    AIM: Analysis of the nature and time course of early complications after laparoscopic colonic surgery is required to allow rational strategies for their prevention and management. METHOD: One hundred and four consecutive patients who underwent elective fast-track laparoscopic colonic cancer surgery...... occurred in 14 patients, of which four were preceded by medical complications. Three patients had only medical complications. Median length of stay was 3 days (range 1-44). CONCLUSION: Further improvement of outcomes after fast-track laparoscopic colonic surgery might be obtained by improved surgical...

  8. Fast-track rehabilitation in elective colorectal surgery patients: a prospective clinical and immunological single-centre study.

    Science.gov (United States)

    Wichmann, Matthias W; Eben, Ricarda; Angele, Martin K; Brandenburg, Franzis; Goetz, Alwin E; Jauch, Karl-Walter

    2007-07-01

    Recent clinical data indicate that fast-track surgery (multimodal rehabilitation) leads to shorter postoperative length of hospital stay, faster recovery of gastrointestinal function as well as reduced morbidity and mortality rates. To date, no study has focused on the effects of fast-track surgery on postoperative immune function. This study was initiated to determine whether fast-track rehabilitation results in improved clinical and immunological outcome of patients undergoing colorectal surgery. Forty patients underwent either conventional or fast-track rehabilitation after colorectal surgery. In addition to clinical parameters (return of gastrointestinal function, food intake, pain score, complication rates and postoperative length of stay), we determined parameters of perioperative immunity by flow cytometry (lymphocyte subgroups) and enzyme-linked immunosorbent assay (interleukin-6). Our findings indicate a better-preserved cell-mediated immune function (T cells, T-helper cells, natural killer cells) after fast-track rehabilitation, whereas the pro-inflammatory response (C-reactive protein, interleukin-6) was unchanged in both study groups. Furthermore, we detected a significantly faster return of gastrointestinal function (first bowel movement P<0.001, food intake P<0.05), significantly reduced pain scores in the postoperative course (P < 0.05) and a significantly shorter length of postoperative stay (P<0.001) in patients undergoing fast-track rehabilitation. Fast-track rehabilitation after colorectal surgery results in better-preserved cell-mediated immunity when compared with conventional postoperative care. Furthermore, patients undergoing fast-track rehabilitation suffer from less pain and have a faster return of gastrointestinal function in the postoperative course. In addition, postoperative length of hospital stay was significantly shorter in fast-track patients.

  9. Electromobility - aspects of energy economy and energy economy law. Pt. 2; Energiewirtschaftliche und energiewirtschaftsrechtliche Fragen der Elektromobilitaet. T. 2

    Energy Technology Data Exchange (ETDEWEB)

    Fest, Claus [RWE Effizienz GmbH, Dortmund (Germany). Umfeldmanagement/Stakeholder; Franz, Oliver [RWE AG, Essen (Germany). Regulierungsmanagement; Gaul, Armin [RWE Rheinland Westfalen Netz AG, Essen (Germany). Assetmanagement

    2010-05-15

    For the political leadership and the industrial sectors involved, the central challenge associated with electromobility will be its integration in an overall transport and energy concept for Germany and Europe. The aim must be to integrate electromobility in the energy supply system such that it is convenient, simple and inexpensive to use. This is the only way to generate the level of acceptance and demand in the population that is needed for achieving full-area market penetration. Electrotechnical and communicative standards and the new concept of e-roaming will play a decisive role in this development process.

  10. The role of pain for early rehabilitation in fast track total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Myhrmann, Lis

    2010-01-01

    To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA).......To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA)....

  11. Getting on the fast track, or how to get an MLIS through distance education, with a specialization in medical librarianship.

    Science.gov (United States)

    Detlefsen, Ellen G

    2004-01-01

    The article describes an innovation in MLIS education for medical librarianship, with an introduction to the FastTrack, the distance education program at the University of Pittsburgh's library and information science school, together with an overview of a model program linking the biomedical library at Vanderbilt University with the School of Information Sciences in Pittsburgh. Admissions requirements and specific curriculum for the distance education master's degree are detailed in an FAQ format.

  12. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    Directory of Open Access Journals (Sweden)

    Lene Bastrup Jørgensen

    2016-01-01

    Full Text Available Aims and objectives: The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background: Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design: The study design used classical grounded theory. Methods: The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results: Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion: In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  13. Restoring integrity--A grounded theory of coping with a fast track surgery programme.

    Science.gov (United States)

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. The study design used classical grounded theory. The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients' main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  14. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    Science.gov (United States)

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    Aims and objectives The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design The study design used classical grounded theory. Methods The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme. PMID:26751199

  15. Fast emulation of track reconstruction in the CMS simulation

    CERN Document Server

    Komm, Matthias

    2017-01-01

    Simulated samples of various physics processes are a key ingredient within analyses to unlock the physics behind LHC collision data. Samples with more and more statistics are required to keep up with the increasing amounts of recorded data. During sample generation, significant computing time is spent on the reconstruction of charged particle tracks from energy deposits which additionally scales with the pileup conditions. In CMS, the FastSimulation package is developed for providing a fast alternative to the standard simulation and reconstruction workflow. It employs various techniques to emulate track reconstruction effects in particle collision events. Several analysis groups in CMS are utilizing the package, in particular those requiring many samples to scan the parameter space of physics models (e.g. SUSY) or for the purpose of estimating systematic uncertainties. The strategies for and recent developments in this emulation are presented, including a novel, flexible implementation of tracking emulation w...

  16. Accelerated Leadership Development: Fast Tracking School Leaders

    Science.gov (United States)

    Earley, Peter; Jones, Jeff

    2010-01-01

    "Accelerated Leadership Development" captures and communicates the lessons learned from successful fast-track leadership programmes in the private and public sector, and provides a model which schools can follow and customize as they plan their own leadership development strategies. As large numbers of headteachers and other senior staff…

  17. E-mobil on the right track. Electromobility: Germans' industry must build up networks if staying in competition; Am E-Mobil geht kein Weg vorbei. Elektromobilitaet: Will die heimische Industrie mitmischen, muss sie starke Netzwerke bilden

    Energy Technology Data Exchange (ETDEWEB)

    Stauss, Olaf

    2010-09-13

    Electromobility is moving on. But Germans industry must hurry up, because Chinas' automotive industry don't sleep. The competition becomes more and more stronger and Germans' companies will win, if they startup immediately. (GL)

  18. Fast-track program vs traditional care in surgery for gastric cancer.

    Science.gov (United States)

    Chen, Zhi-Xing; Liu, Ae-Huey Jennifer; Cen, Ying

    2014-01-14

    To systematically review the evidence for the effectiveness of fast-track program vs traditional care in laparoscopic or open surgery for gastric cancer. PubMed, Embase and the Cochrane library databases were electronically searched for published studies between January 1995 and April 2013, and only randomized trials were included. The references of relevant studies were manually searched for further studies that may have been missed. Search terms included "gastric cancer", "fast track" and "enhanced recovery". Five outcome variables were considered most suitable for analysis: postoperative hospital stay, medical cost, duration to first flatus, C-reactive protein (CRP) level and complications. Postoperative hospital stay was calculated from the date of operation to the date of discharge. Fixed effects model was used for meta-analysis. Compared with traditional care, fast-track program could significantly decrease the postoperative hospital stay [weighted mean difference (WMD) = -1.19, 95%CI: -1.79--0.60, P = 0.0001, fixed model], duration to first flatus (WMD = -6.82, 95%CI: -11.51--2.13, P = 0.004), medical costs (WMD = -2590, 95%CI: -4054--1126, P = 0.001), and the level of CRP (WMD = -17.78, 95%CI: -32.22--3.35, P = 0.0001) in laparoscopic surgery for gastric cancer. In open surgery for gastric cancer, fast-track program could also significantly decrease the postoperative hospital stay (WMD = -1.99, 95%CI: -2.09--1.89, P = 0.0001), duration to first flatus (WMD = -12.0, 95%CI: -18.89--5.11, P = 0.001), medical cost (WMD = -3674, 95%CI: -5025--2323, P = 0.0001), and the level of CRP (WMD = -27.34, 95%CI: -35.42--19.26, P = 0.0001). Furthermore, fast-track program did not significantly increase the incidence of complication (RR = 1.39, 95%CI: 0.77-2.51, P = 0.27, for laparoscopic surgery; and RR = 1.52, 95%CI: 0.90-2.56, P = 0.12, for open surgery). Our overall results suggested that compared with traditional care, fast-track program could result in shorter

  19. Market-phase-oriented promotion of electromobility; Phasenbezogene Foerderung von Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Fornahl, Dirk; Diller, Matthias [BAW Institut fuer regionale Wirtschaftsforschung GmbH, Bremen (Germany)

    2010-12-15

    Increasingly, the automobile industry is calling for state funds for electromobility. However, to achieve the goal of large-scale diffusion of grid-powered electric vehicles, the following points must be considered before deciding on appropriate promotion instruments: All products that are launched go through several phases before they are fully established in the market, and appropriate promotion measures are must be selected for each stage, in consideration of greatly different economic criteria. Against this background, a promotion strategy oriented along the various market phases must be developed.

  20. Successful integration of fast track projects into turnarounds

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J. Patrick; Loureiro, Ramon C. [KBC Advanced Technologies, Surrey (United Kingdom)

    2012-07-01

    Fast track projects can provide quick wins and competitive advantage. However, in most cases the implementation of these projects requires a shutdown for installing the necessary tie-ins or integration into an upcoming turnaround (TA). Depending on the nature of the project and complexity of the TA, the integration can be seamless or result in cost or duration overruns and safety incidents. The risk of such overruns and safety incidents increases with the amount of project work to be integrated into the operations, maintenance and inspection schedules to be executed during the TA. The risk further increases with TA size and other factors. If not planned and scheduled properly and in a timely fashion, capital projects, in particular fast track projects trying to take advantage of an upcoming TA, can severely impact both TA performance, and the safety and reliability of the facility until the next opportunity for eliminating the defects introduced during the TA. Successful TAs are those delivered in a safe, on time, on budget manner, and with the quality standards needed for a leak-free start-up and a safe and reliable operation over the next run cycle. This paper discusses the key elements that are required to minimize the TA risks derived from the inclusion of fast track projects and how to establish the cut off criteria to either cancel or defer the project, or delay the TA in order to balance TA scope freeze and the case for compelling economics.(author)

  1. Fast and Practical Head Tracking in Brain Imaging with Time-of-Flight Camera

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Jensen, Rasmus Ramsbøl

    2013-01-01

    scanners. Particularly in MRI and PET, the newest generation of TOF cameras could become a method of tracking small and large scale patient movement in a fast and user friendly way required in clinical environments. We present a novel methodology for fast tracking from TOF point clouds without the need...

  2. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  3. Comparison of remifentanil and low-dose fentanyl for fast-track cardiac anesthesia

    DEFF Research Database (Denmark)

    Khanykin, Boris; Siddiqi, Rizwan; Jensen, Per F

    2013-01-01

    BACKGROUND: Different anesthetic techniques have been used for fast tracking in cardiac anesthesia. Remifentanil, with its unique pharmacokinetic profile, could be an ideal drug for fast tracking. Possible limitations of remifentanil are rapid onset of postoperative pain after discontinuation...... of the drug infusion, which may increase the risk of an ischemic event. We conducted this randomized study to compare the efficacy of remifentanil versus low doses of fentanyl in fast-track cardiac anesthesia. It has been hypothesized that remifentanil would provide a safe anesthesia with no impact...... anesthesia. The study was designed as a prospective randomized study. The primary outcomes were changes in the cardiac index and creatine kinase MB fraction (CKMB), extubation times, mobilization times, and lengths of stay in the intensive care unit (ICU) and the hospital. Frequency of myocardial infarction...

  4. PUC fast track nips returns

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the first of what it says will be annual cost-of-capital proceedings to set returns on equity and rates of return on rate base for electric utilities, the California Public Utilities Commission (PUC) lowered from 1989 levels the 1990 returns on common equity (ROE) and rates of return (ROR) for the state's four major investor-owned electric utilities. Under this fast-track procedure, by May 8 of every year, utilities will have to file an application for rate adjustments that reflect their projected costs of capital for the following year

  5. New concepts of infrastructure for electromobility; Neue Infrastrukturkonzepte fuer Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstein, Christian von; Hoff, Stefanie von [RAUE LLP, Berlin (Germany)

    2011-06-15

    The successful implementation of electromobility requires a greatest possible area-wide charging infrastructure. Current pilot projects use this charging infrastructure with an integrated measuring equipment. Alternative systems are explored for the charging of electric vehicles and developed based on mobile measurement technology. Under this aspect, the authors of the contribution report on new infrastructure concepts for electric vehicles. Two questions are discussed: (a) How can the charging infrastructure be implemented in the existing regulatory system of the Energy Economy Law?; (b) Is an implementation of mobile devices into existing energy-economic processes possible?.

  6. Trevino Project: a fast-track approach for a small construction project

    International Nuclear Information System (INIS)

    Schick, C.J.; Lynn, N.S.

    1982-01-01

    The approach to a construction project can vary according to the size, location, and degree of difficulty associated with the project. This paper deals with one approach that can be taken to a small construction project, the fast-track approach. A small construction project can be defined as a project having less than $20 million capital cost or a project with a low degree of difficulty. This approach is very applicable to in-situ leaching uranium projects, small precious metal operations, etc. The approach to the small project is that of fast-tracking the project in order to minimize the time over which capital expenditure occurs and also to reduce the indirect costs of field expense, construction supplies, construction equipment, etc. In order to fast-track a project it is necessary to do a very precise job on the preliminary phases of the project such as preliminary engineering, plant site location, environmental permits, etc. 2 figures, 2 tables

  7. The risk of manipulation under anesthesia due to unsatisfactory knee flexion after fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Wied, Christian; Thomsen, Morten G; Kallemose, Thomas

    2015-01-01

    BACKGROUND: Fast-track TKA has significantly shortened the time available for physiotherapists to optimize knee ROM before discharge. Safety aspects concerning knee stiffness and the need for manipulation in a fast-track setting need to be illuminated. The study aims were to analyze if fast-track...

  8. Time-driven Activity-based Cost of Fast-Track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Andreasen, Signe E; Holm, Henriette B; Jørgensen, Mira

    2017-01-01

    this between 2 departments with different logistical set-ups. METHODS: Prospective data collection was analyzed using the time-driven activity-based costing method (TDABC) on time consumed by different staff members involved in patient treatment in the perioperative period of fast-track THA and TKA in 2 Danish...... orthopedic departments with standardized fast-track settings, but different logistical set-ups. RESULTS: Length of stay was median 2 days in both departments. TDABC revealed minor differences in the perioperative settings between departments, but the total cost excluding the prosthesis was similar at USD......-track methodology, the result could be a more cost-effective pathway altogether. As THA and TKA are potentially costly procedures and the numbers are increasing in an economical limited environment, the aim of this study is to present baseline detailed economical calculations of fast-track THA and TKA and compare...

  9. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been...

  10. Fast-Track Cleanup at Closing DoD Installations

    Science.gov (United States)

    The Fast-Track Cleanup program strives to make parcels available for reuse as quickly as possible by the transfer of uncontaminated or remediated parcels, the lease of contaminated parcels where cleanup is underway, or the 'early transfer' of contaminated property undergoing cleanup.

  11. Patient-reported outcome after fast-track knee arthroplasty

    DEFF Research Database (Denmark)

    Larsen, Kristian; Hansen, Torben B; Søballe, Kjeld

    2012-01-01

    PURPOSE: The purpose of this study was to describe patient-related functional outcomes after fast-track total knee arthroplasty and unicompartmental knee arthroplasty. Furthermore, we wanted to assess physical areas where an additional need for rehabilitation could be identified, and finally, we...

  12. Design of a Hardware Track Finder (Fast Tracker) for the ATLAS Trigger

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00010976; Albicocco, P.; Alison, J.; Ancu, L.S.; Anderson, J.; Andari, N.; Andreani, A.; Andreazza, A.; Annovi, A.; Antonelli, M.; Asbah, N.; Atkinson, M.; Baines, J.; Barberio, E.; Beccherle, R.; Beretta, M.; Bertolucci, F.; Biesuz, N.V.; Blair, R.; Bogdan, M.; Boveia, A.; Britzger, D.; Bryant, P.; Burghgrave, B.; Calderini, G.; Camplani, A.; Cavasinni, V.; Chakraborty, D.; Chang, P.; Cheng, Y.; Citraro, S.; Citterio, M.; Crescioli, F.; Dawe, N.; Dell'Orso, M.; Donati, S.; Dondero, P.; Drake, G.; Gadomski, S.; Gatta, M.; Gentsos, C.; Giannetti, P.; Gkaitatzis, S.; Gramling, J.; Howarth, J.W.; Iizawa, T.; Ilic, N.; Jiang, Z.; Kaji, T.; Kasten, M.; Kawaguchi, Y.; Kim, Y.K.; Kimura, N.; Klimkovich, T.; Kolb, M.; Kordas, K.; Krizka, K.; Kubota, T.; Lanza, A.; Li, H.L.; Liberali, V.; Lisovyi, M.; Liu, L.; Love, J.; Luciano, P.; Luongo, C.; Magalotti, D.; Maznas, I.; Meroni, C.; Mitani, T.; Nasimi, H.; Negri, A.; Neroutsos, P.; Neubauer, M.; Nikolaidis, S.; Okumura, Y.; Pandini, C.; Petridou, C.; Piendibene, M.; Proudfoot, J.; Rados, P.; Roda, C.; Rossi, E.; Sakurai, Y.; Sampsonidis, D.; Saxon, J.; Schmitt, S.; Schoening, A.; Shochet, M.; Shojaii, S.; Soltveit, H.; Sotiropoulou, C.L.; Stabile, A.; Swiatlowski, M.; Tang, F.; Taylor, P.T.; Testa, M.; Tompkins, L.; Vercesi, V.; Volpi, G.; Wang, R.; Watari, R.; Webster, J.; Wu, X.; Yorita, K.; Yurkewicz, A.; Zeng, J.C.; Zhang, J.; Zou, R.

    2016-01-01

    The use of tracking information at the trigger level in the LHC Run II period is crucial for the trigger an data acquisition (TDAQ) system and will be even more so as contemporary collisions that occur at every bunch crossing will increase in Run III. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide every Level-1 accepted event (100 kHz) and within 100$\\mu$s, full tracking information for tracks with momentum as low as 1 GeV. Providing fast, extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondary vertices to ensure robust selections and improve the trigger performance.

  13. Convalescence after colonic resection with fast-track versus conventional care

    DEFF Research Database (Denmark)

    Hjort Jakobsen, D; Sonne, E; Basse, L

    2004-01-01

    BACKGROUND: Multi-modal rehabilitation programmes may improve early postoperative body composition, pulmonary function, exercise capacity, and reduce hospital stay. So far, no data are available on convalescence after discharge. AIM: The objectives were to compare convalescence data (fatigue, sleep...... vs. 8 days in the fast-track vs. conventional care group, respectively (p sleep were increased in the conventional care group when compared with the fast-track group (p ... results in earlier resumption of normal activities with reduced fatigue and need for sleep postoperatively compared to conventional care, and without increased need for nursing care or visits to general practitioners. However, readmissions may occur more frequently....

  14. Why still in hospital after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Lunn, Troels H; Troelsen, Anders

    2011-01-01

    Background and purpose Length of stay (LOS) following total hip and knee arthroplasty (THA and TKA) has been reduced to about 3 days in fast-track setups with functional discharge criteria. Earlier studies have identified patient characteristics predicting LOS, but little is known about specific...... reasons for being hospitalized following fast-track THA and TKA. Patients and methods To determine clinical and logistical factors that keep patients in hospital for the first postoperative 24-72 hours, we performed a cohort study of consecutive, unselected patients undergoing unilateral primary THA (n...

  15. National platform electromobility. Interim report of the NPE AG 6 - Education and qualification; Nationale Plattform Elektromobilitaet. Zwischenbericht der NPE AG 6 - Ausbildung und Qualifizierung

    Energy Technology Data Exchange (ETDEWEB)

    Goericke, Dietmar [Forschungsvereinigung Verbrennungskraftmaschinen e.V., Frankfurt am Main (Germany)

    2010-07-01

    On behalf of the working group 6 ''Education and qualification'' of the national platform electromobility arranged by the Federal Government, the academic and occupational education and advanced training had to be aligned to the targets of the national platform electromobility. In the context of an ABC analysis, the academic and professional educational offerings in Germany were analyzed according to the strengths and weaknesses. From this, recommendations for action were derived for the compensation of these deficits.

  16. Controlling type I error rate for fast track drug development programmes.

    Science.gov (United States)

    Shih, Weichung J; Ouyang, Peter; Quan, Hui; Lin, Yong; Michiels, Bart; Bijnens, Luc

    2003-03-15

    The U.S. Food and Drug Administration (FDA) Modernization Act of 1997 has a Section (No. 112) entitled 'Expediting Study and Approval of Fast Track Drugs' (the Act). In 1998, the FDA issued a 'Guidance for Industry: the Fast Track Drug Development Programs' (the FTDD programmes) to meet the requirement of the Act. The purpose of FTDD programmes is to 'facilitate the development and expedite the review of new drugs that are intended to treat serious or life-threatening conditions and that demonstrate the potential to address unmet medical needs'. Since then many health products have reached patients who suffered from AIDS, cancer, osteoporosis, and many other diseases, sooner by utilizing the Fast Track Act and the FTDD programmes. In the meantime several scientific issues have also surfaced when following the FTDD programmes. In this paper we will discuss the concept of two kinds of type I errors, namely, the 'conditional approval' and the 'final approval' type I errors, and propose statistical methods for controlling them in a new drug submission process. Copyright 2003 John Wiley & Sons, Ltd.

  17. Fast tracking in adult cardiac surgery at Pakistan Institute of Medical Sciences

    International Nuclear Information System (INIS)

    Ahmed, N.; Khan, F.; Zahoor, M.; Rafique, M.; Faisal, M.

    2010-01-01

    Background: Early extubation after cardiac operation is an important aspect of fast-track cardiac anaesthesia. The length of stay in ICU limits utilisation of operation theatre in cardiac surgery. Increasing cost, limited resources, and newer surgical strategies have stimulated effectiveness of all routines in cardiac surgery, anaesthesia, and intensive care. Aim of this study was to determine the feasibility of fast-tracking in adult cardiac surgery and its effects on post operative recovery in our setup. Methods: This descriptive study was conducted over 14 months between Jul 16, 2007 to Sep 16, 2008. All the open heart cases were included unless absolute contraindications were there. We applied the rapid recovery protocol adopted from Oslo Hospital Norway in an attempt to achieve fast-tracking in our setup. Results: Two-hundred-seventy-four consecutive cases out of 400 operated cases were included in this study. Mean age was 47.69 +- 15.11 years, 27.7% were females, 5.8% were emergency cases, 5.1% were COPD, 11.1% were atrial fibrillation, and 6.9% were NYHA class-III cases. CABG was done in 66.1% cases and mean CPB-time was 75.92 +- 16.20 min. Mean Ventilation-time was 4.47+-4.48 hrs., 86% patients were fast-tracked to be extubated within 6 hours, and 85.4% patients remained free of post-op complications. Six (2.2%) re-intubatIions, 2.6% arrhythmias, 6.6% pleural effusions and 2.2% consolidation were observed post-operatively. Mean ICU stay was 2.49 +- 0.95 days and in-hospital mortality was 2.2%. Conclusion: Fast-tracking with extubation within 6 hours is feasible approach which minimises the post-operative complications significantly in adult cardiac surgical patients. (author)

  18. Innovation and Market-Driven Management in Fast Fashion Companies

    OpenAIRE

    Elisa Arrigo

    2010-01-01

    In hyper-competitive markets, innovation is critical for the growth of market-driven companies. An examination of case studies of highly competitive global companies in the fast fashion sector, reveals that detailed understanding of the market, deriving from direct management of their stores, enables Zara, Gap and H&M to develop an innovation management capability. This is a fundamental competitive driver for the company's success.

  19. A fast neutron detector with IP by track measurement

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Yang Jun; Zhang Qiang; Zhao Xiangfeng; Wang Daohua

    2004-01-01

    Imaging Plate(IP) is very sensitive to electric particles, especially to heavy ions. As we know, the recoiling protons are produced while fast neutrons scattered in light material containing hydrogen. When the recoiling proton enters in the sensitive layer of IP, a track will be recorded by IP. In this paper, a fast neutron detector based on IP and (n, p) reaction is described in detail, the detector's efficiency is studied also. (authors)

  20. Fast track trigger processor for the OPAL detector at LEP

    Energy Technology Data Exchange (ETDEWEB)

    Carter, A A; Carter, J R; Ward, D R; Heuer, R D; Jaroslawski, S; Wagner, A

    1986-09-20

    A fast hardware track trigger processor being built for the OPAL experiment is described. The processor will analyse data from the central drift chambers of OPAL to determine whether any tracks come from the interaction region, and thereby eliminate background events. The processor will find tracks over a large angular range, vertical strokecos thetavertical stroke < or approx. 0.95. The design of the processor is described, together with a brief account of its hardware implementation for OPAL. The results of feasibility studies are also presented.

  1. The ATLAS Fast Tracker Processing Units - track finding and fitting

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00384270; The ATLAS collaboration; Alison, John; Ancu, Lucian Stefan; Andreani, Alessandro; Annovi, Alberto; Beccherle, Roberto; Beretta, Matteo; Biesuz, Nicolo Vladi; Bogdan, Mircea Arghir; Bryant, Patrick; Calabro, Domenico; Citraro, Saverio; Crescioli, Francesco; Dell'Orso, Mauro; Donati, Simone; Gentsos, Christos; Giannetti, Paola; Gkaitatzis, Stamatios; Gramling, Johanna; Greco, Virginia; Horyn, Lesya Anna; Iovene, Alessandro; Kalaitzidis, Panagiotis; Kim, Young-Kee; Kimura, Naoki; Kordas, Kostantinos; Kubota, Takashi; Lanza, Agostino; Liberali, Valentino; Luciano, Pierluigi; Magnin, Betty; Sakellariou, Andreas; Sampsonidis, Dimitrios; Saxon, James; Shojaii, Seyed Ruhollah; Sotiropoulou, Calliope Louisa; Stabile, Alberto; Swiatlowski, Maximilian; Volpi, Guido; Zou, Rui; Shochet, Mel

    2016-01-01

    The Fast Tracker is a hardware upgrade to the ATLAS trigger and data-acquisition system, with the goal of providing global track reconstruction by the start of the High Level Trigger starts. The Fast Tracker can process incoming data from the whole inner detector at full first level trigger rate, up to 100 kHz, using custom electronic boards. At the core of the system is a Processing Unit installed in a VMEbus crate, formed by two sets of boards: the Associative Memory Board and a powerful rear transition module called the Auxiliary card, while the second set is the Second Stage board. The associative memories perform the pattern matching looking for correlations within the incoming data, compatible with track candidates at coarse resolution. The pattern matching task is performed using custom application specific integrated circuits, called associative memory chips. The auxiliary card prepares the input and reject bad track candidates obtained from from the Associative Memory Board using the full precision a...

  2. A fast fiducial marker tracking model for fully automatic alignment in electron tomography

    KAUST Repository

    Han, Renmin; Zhang, Fa; Gao, Xin

    2017-01-01

    Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner.In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers.The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the

  3. A fast fiducial marker tracking model for fully automatic alignment in electron tomography

    KAUST Repository

    Han, Renmin

    2017-10-20

    Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner.In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers.The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the

  4. National research activities in the whole context electromobility; Nationale Forschungsaktivitaeten im Gesamtkontext Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Schoettle, Markus

    2010-08-15

    In the year 2020 1 Million electric-powered vehicles are aimed to move on Germanys roads according to the National Development Plan Electromobility. This will cause effective activites: Research and development of vehicles, new organization of energy supply and infrastructure as traffic grids and mobility concepts. Therefore measure should be communicated more arranged until end of year. ATZelektronic develops schedules with focus on research projects in the automotive sector. (orig./GL)

  5. Implementation of the scientific evidence into daily practice - example from fast-track colonic cancer surgery

    DEFF Research Database (Denmark)

    Hammer, J.; Harling, H.; Wille-Jorgensen, P.

    2008-01-01

    Objective To report the implementation and results of fast-track surgery for colonic cancer in the daily routine. Method A total of 131 consecutive patients scheduled for elective colonic cancer resections entered a fast-track perioperative course after thorough information. The regimen contained...

  6. ATLAS Fast Tracker Status and Tracking at High luminosity LHC

    CERN Document Server

    Ilic, Nikolina; The ATLAS collaboration

    2018-01-01

    The LHC’s increase in centre of mass energy and luminosity in 2015 makes controlling trigger rates with high efficiency challenging. The ATLAS Fast TracKer (FTK) is a hardware processor built to reconstruct tracks at a rate of up to 100 kHz and provide them to the high level trigger. The FTK reconstructs tracks by matching incoming detector hits with pre-defined track patterns stored in associative memory on custom ASICs. Inner detector hits are fit to these track patterns using modern FPGAs. This talk describes the electronics system used for the FTK’s massive parallelization. The installation, commissioning and running of the system is happening in 2016, and is detailed in this talk. Tracking at High luminosity LHC is also presented.

  7. Electromobility as a reasonable electrical interim storage? Perspectives; Elektromobilitaet als sinnvoller elektrischer Zwischenspeicher? Perspektiven

    Energy Technology Data Exchange (ETDEWEB)

    Taenzer, Guillem [IZES gGmbH, Saarbruecken (Germany)

    2011-07-01

    Electromobility seems a promising future technology in order to replace the combustion engine predominance in the individual traffic due to the upcoming shortage of resource and the climate relevance. In addition consists the potential of electric cars, insofar unused and attached to the energy grid, for contributions to the load balance, especially against the background of the developments goals of the renewable energies and its fluctuating supply. In the end these potentials are limited: electric cars, respectively the accumulators can only stabilize short-term load fluctuations (minute-related reserve, hours-related reserve) in the electric grid, long-term (seasonal) adjustment options are here not possible. Further problems to solve are the construction of an appropriate charge and feeding-back infrastructure with adequate power output > 10 kW as well as to attain an admissible consumer acceptance which divulge his cruising range in conjunction of negative consequence to the durability of the accumulator. Therefore the contribution of the electromobility to the energy system will be marginal but can deliver (for now) an input to the fluctuating load in the power grid, which should be exploited. (orig.)

  8. L0 Confirmation with fast, Tsa based tracking in the T-stations

    CERN Document Server

    Albrecht, J; Terrier, H

    2007-01-01

    A fast tracking algorithm to confirm the high $p_T$ L0 trigger objects with tracks from the T-stations is presented. The L0 trigger candidate is used to define a search window to a potential track. Using this, a seeded track search is performed. The track finding algorithm is based on the \\textit{TsaSeeding} algorithm~\\cite{bib:Tsa}. The efficiency to confirm a true L0 trigger signal is around 96\\%, the momentum can be measured up to $\\Delta p/p$=3\\%.

  9. Low manipulation prevalence following fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C.; Gromov, Kirill

    2015-01-01

    BACKGROUND AND PURPOSE: Postoperative joint stiffness following total knee arthroplasty (TKA) may compromise the outcome and necessitate manipulation. Previous studies have not been in a fast-track setting with optimized pain treatment, early mobilization, and short length of stay (LOS), which ma...

  10. After colonic surgery: The lived experience of participating in a fast-track programme

    DEFF Research Database (Denmark)

    Norlyk, Annelise; Harder, Ingegerd

    2009-01-01

    Postoperative recovery can be accelerated and hospitalization reduced through fast-track programmes. However, documented knowledge is limited and primarily focusing on a medical perspective whereas the patients' perspective lacks documentation. This study describes the lived experience of partici......Postoperative recovery can be accelerated and hospitalization reduced through fast-track programmes. However, documented knowledge is limited and primarily focusing on a medical perspective whereas the patients' perspective lacks documentation. This study describes the lived experience...

  11. Mass tracking and material accounting in the integral fast reactor (IFR)

    International Nuclear Information System (INIS)

    Orechwa, Y.; Adams, C.H.; White, A.M.

    1991-01-01

    This paper reports on the Integral Fast Reactor (IFR) which is a generic advanced liquid metal cooled reactor concept being developed at Argonne National Laboratory. There are a number of technical features of the IFR which contribute to its potential as a next-generation reactor. These are associated with large safety margins with regard to off-normal events involving the heat transport system, and the use of metallic fuel which makes possible the utilization of innovative fuel cycle processes. The latter feature permits fuel cycle closure with compact, low-cost reprocessing facilities, collocated with the reactor plant. These primary features are being demonstrated in the facilities at ANL-West, utilizing Experimental Breeder Reactor II and the associated Fuel Cycle Facility (FCF) as an IFR prototype. The demonstration of this IFR prototype includes the design and implementation of the Mass-tracking System (MTG). In this system, data from the operations of the FCF, including weights and batch-process parameters, are collected and maintained by the MTG running on distributed workstations

  12. A modified fast-track program for pancreatic surgery: a prospective single-center experience.

    Science.gov (United States)

    di Sebastiano, Pierluigi; Festa, Leonardina; De Bonis, Antonio; Ciuffreda, Andrea; Valvano, Maria Rosa; Andriulli, Angelo; di Mola, F Francesco

    2011-03-01

    The objective of this study is to evaluate the impact of a fast-track protocol in a high-volume center for patients with pancreatic disorders. The concept of fast-track surgery allowing accelerated postoperative recovery is accepted in colorectal surgery, but efficacy data are only preliminary for patients undergoing major pancreatic surgery. We aimed to evaluate the impact of a modified fast-track protocol in a high-volume center for patients with pancreatic disorders. Between February 2005 and January 2010, 145 subjects had resective pancreatic surgery and were enrolled in the program. Essential features of the program were no preanaesthetic medication, upper and lower air-warming device, avoidance of excessive i.v. fluids perioperatively, effective control of pain, early reinstitution of oral feeding, and immediate mobilization and restoration of bowel function following surgery. Outcome measures were postoperative complications such as pancreatic fistula, delayed gastric emptying, biliary leak, intra-abdominal abscess, post-pancreatectomy hemorrhage, acute pancreatitis, wound infection, 30-day mortality, postoperative hospital stay, and readmission rates. On average, patients were discharged on postoperative day 10 (range 6-69), with a 30-day readmission rate of 6.2%. Percentage of patients with at least one complication was 38.6%. Pancreatic anastomotic leakage occurred in seven of 101 pancreatico-jejunostomies, and biliary leak in three of 109 biliary jejunostomies. Postoperative hemorrhage occurred in ten (6.9%) patients and wound infection in nine (6.2%) cases. In-hospital mortality was 2.7%. Fast-track parameters, such as normal food and first stool, correlated significantly with early discharge (jaundice, and resumption of normal diet by the 5th postoperative day were independent factors of early discharge. Fast-track programs are feasible, easy, and also applicable for patients undergoing a major surgery such as pancreatic resection.

  13. Environmental Impact Assessment of Kathmandu Terai Fast-Track

    Directory of Open Access Journals (Sweden)

    Padam Kanta Dahal

    2014-12-01

    Full Text Available  Road transport is dominant necessity for the overall economic development of any nation. In case of Nepal, an easy access between the Capital City and Terai, the store-house of the country and is very necessary. To facilitate this promotion of an improved core road network, Government of Nepal has launched the Kathmandu Terai Fast Track Project. Many concerned personalities and sectors had considered this project to be number one in the list of seventeen projects of national pride declared by the government. The main objective of this study was to identify the impacts of proposed project implementation on physical, biological, socio-economic and cultural environment of the project area and propose mitigation measures to avoid or mitigate such impacts. Primary information collection and secondary data review was the source of data with cross sectional descriptive study design. Data was taken purposively in the project affected area. Length of 72.6 km fast track from Kathmandu – Lalitpur – Makawanpur and up to Nijgadh in Bara district to link with the East West Highway will be of four lanes with 50 m on each side. The project was proposed to have 96 bridges big or small; 1.6 km long tunnel will be built in Thingan of Makawanpur on public-private partnership. It had projected costs of more than NRs 250 million. The impacts on land use will be on about 30km of agricultural land, 43km of forests and about 3km of other land uses, bridges etc. in the main alignment. The impacts on human life will mainly be in villages near the alignment. There are 38 villages within about 50m of the main alignment. The project can be continued with minimum of environmental degradation by applying the mitigation measures. Nation has been investing a lot of resources. Upon the completion of the fast track, the distance and time to reach the capital city from Terai will come down to only 1.5 hours and will transform the capital, eastern Terai and the country as a

  14. Orthostatic intolerance during early mobilization after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, O; Bundgaard-Nielsen, M; Solgaard, S

    2012-01-01

    has not been established after THA. This study evaluated the cardiovascular response and tissue oxygenation to mobilization before and after surgery in relation to OI in fast-track THA patients. METHODS: /st>OI and the cardiovascular response to standing were evaluated with a standardized mobilization......BACKGROUND: /st>Early postoperative mobilization is a cornerstone in fast-track total hip arthroplasty (THA), but postoperative orthostatic intolerance (OI) may delay early recovery or lead to fainting, falls, and prosthesis dislocation or fracture. However, the prevalence and pathophysiology of OI...... protocol, before, 6, and 24 h after surgery in 26 patients undergoing THA with spinal anaesthesia and an opioid-sparing analgesic regime. Haemoglobin, fluid balance, and opioid use were recorded. Systolic (SAP) and diastolic (DAP) arterial pressure, heart rate (HR), stroke volume (SV), cardiac output (CO...

  15. Fast pattern recognition with the ATLAS L1Track trigger for HL-LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00530554; The ATLAS collaboration

    2017-01-01

    A fast hardware based track trigger is being developed in ATLAS for the High Luminosity upgrade of the Large Hadron Collider. The goal is to achieve trigger levels in the high pile-up conditions of the High Luminosity Large Hadron Collider that are similar or better than those achieved at low pile-up conditions by adding tracking information to the ATLAS hardware trigger. A method for fast pattern recognition using the Hough transform is investigated. In this method, detector hits are mapped onto a 2D parameter space with one parameter related to the transverse momentum and one to the initial track direction. The performance of the Hough transform is studied at different pile-up values. It is also compared, using full event simulation of events with average pile-up of 200, with a method based on matching detector hits to pattern banks of simulated tracks stored in a custom made Associative Memory ASICs. The pattern recognition is followed by a track fitting step which calculates the track parameters. The spee...

  16. Hardware-based tracking at trigger level for ATLAS: The Fast Tracker (FTK) Project

    CERN Document Server

    Gramling, Johanna; The ATLAS collaboration

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer (FTK) is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level 1 trigger (at a maximum rate of 100 kHz) the FTK receives data from the 80 million channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware-based track reconstruction, using associative memory (AM) that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. Narrow roads permit a fast track fitting but need many patterns stored in the AM to ensure ...

  17. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    INTRODUCTION: Most institutions perform percutaneous liver biopsy with a post-biopsy patient observation period lasting up to eight hours, which is resource-demanding. This study aimed to evaluate the safety of liver biopsy performed in a fast-track set-up with an only one-hour post......-biopsy observation time. METHODS: Patients referred to our institution underwent fast-track ultrasound-guided 18-gauge Tru-Cut liver biopsy procedures. Each single biopsy procedure was followed by a post-procedure observational period of one hour and an additional focused assessment with sonography for trauma before...... safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  18. Fast pattern recognition with the ATLAS L1 track trigger for the HL-LHC

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2016-01-01

    A fast hardware based track trigger for high luminosity upgrade of the Large Hadron Collider (HL- LHC) is being developed in ATLAS. The goal is to achieve trigger levels in high pileup collisions that are similar or even better than those achieved at low pile-up running of LHC by adding tracking information to the ATLAS hardware trigger which is currently based on information from calorimeters and muon trigger chambers only. Two methods for fast pattern recognition are investigated. The first is based on matching tracker hits to pattern banks of simulated high momentum tracks which are stored in a custom made Associative Memory (AM) ASIC. The second is based on the Hough transform where detector hits are transformed into 2D Hough space with one variable related to track pt and one to track direction. Hits found by pattern recognition will be sent to a track fitting step which calculates the track parameters . The speed and precision of the track fitting depends on the quality of the hits selected by the patte...

  19. Comparison of fast neutron-induced tracks in plastics using the electrochemical etching method

    International Nuclear Information System (INIS)

    Cotter, S.J.; Gammage, R.B.; Thorngate, J.H.; Ziemer, P.L.

    1979-01-01

    Four plastics were examined by the electrochemical etching method for their suitability in registering fast neutron-induced recoil particle tracks. The plastics were cellulose acetate, cellulose triacetate, cellulose acetobutyrate and polycarbonate. Cellulose acetate and triacetate displayed high levels of water absorptivity during etching while the acetobutyrate foils cracked due to electromechanical stresses at high frequencies (>500 Hz). The clarity of the etched track was superior in the polycarbonate foils, suggesting the latter as the generally preferred dosimeter for fast neutrons. (author)

  20. A fast track trigger processor for the OPAL detector at LEP

    International Nuclear Information System (INIS)

    Carter, A.A.; Jaroslawski, S.; Wagner, A.

    1986-01-01

    A fast hardware track trigger processor being built for the OPAL experiment is described. The processor will analyse data from the central drift chambers of OPAL to determine whether any tracks come from the interaction region, and thereby eliminate background events. The processor will find tracks over a large angular range, vertical strokecos thetavertical stroke < or approx. 0.95. The design of the processor is described, together with a brief account of its hardware implementation for OPAL. The results of feasibility studies are also presented. (orig.)

  1. Fast simulation of the forward tracking detector of HPLUS

    International Nuclear Information System (INIS)

    Zhang Yapeng; Fan Ruirui; Fu Fen; Yue Ke; Yuan Xiaohua; Xu Huagen; Chinese Academy of Sciences, Beijing; Yao Nan; Xu Hushan; Jin Genming; Liang Jinjie; Chen Ruofu; Sun Zhiyu; Duan Limin; Xiao Zhigang; Tsinghua Univ., Beijing

    2008-01-01

    The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics Lanzhou Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp→pp+φ(→K + K - ), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed φ are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp→pp+K + K - as background. The geometry coverage of FTD for qb events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS. (authors)

  2. Fast neural-net based fake track rejection in the LHCb reconstruction

    CERN Document Server

    De Cian, Michel; Seyfert, Paul; Stahl, Sascha

    2017-01-01

    A neural-network based algorithm to identify fake tracks in the LHCb pattern recognition is presented. This algorithm, called ghost probability, retains more than 99 % of well reconstructed tracks while reducing the number of fake tracks by 60 %. It is fast enough to fit into the CPU time budget of the software trigger farm and thus reduces the combinatorics of the decay reconstructions, as well as the number of tracks that need to be processed by the particle identification algorithms. As a result, it strongly contributes to the achievement of having the same reconstruction online and offline in the LHCb experiment in Run II of the LHC.

  3. Delirium in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Kurbegovic, Sorel; Andersen, Jens; Krenk, Lene

    2015-01-01

    BACKGROUND: Postoperative delirium (PD) is a common but serious problem after major surgery with a multifactorial pathogenesis including age, pain, opioid use, sleep disturbances and the surgical stress response. These factors have been minimised by the "fast-track methodology" previously...... demonstrated to enhance recovery and reduce morbidity. METHODS: Clinical symptoms of PD were routinely collected three times daily from preoperatively until discharge in a well-defined enhanced recovery program after colonic surgery in 247 consecutive patients. RESULTS: Total median length of hospital stay...... postoperative recovery program may decrease the risk and duration of PD after colonic surgery....

  4. The yield of colorectal cancer among fast track patients with normocytic and microcytic anaemia.

    Science.gov (United States)

    Panagiotopoulou, I G; Fitzrol, D; Parker, R A; Kuzhively, J; Luscombe, N; Wells, A D; Menon, M; Bajwa, F M; Watson, M A

    2014-05-01

    We receive fast track referrals on the basis of iron deficiency anaemia (IDA) for patients with normocytic anaemia or for patients with no iron studies. This study examined the yield of colorectal cancer (CRC) among fast track patients to ascertain whether awaiting confirmation of IDA is necessary prior to performing bowel investigations. A review was undertaken of 321 and 930 consecutive fast track referrals from Centre A and Centre B respectively. Contingency tables were analysed using Fisher's exact test. Logistic regression analyses were performed to investigate significant predictors of CRC. Overall, 229 patients were included from Centre A and 689 from Centre B. The odds ratio for microcytic anaemia versus normocytic anaemia in the outcome of CRC was 1.3 (95% confidence interval [CI]: 0.5-3.9) for Centre A and 1.6 (95% CI: 0.8-3.3) for Centre B. In a logistic regression analysis (Centre B only), no significant difference in CRC rates was seen between microcytic and normocytic anaemia (adjusted odds ratio: 1.9, 95% CI: 0.9-3.9). There was no statistically significant difference in the yield of CRC between microcytic and normocytic anaemia (p=0.515, Fisher's exact test) in patients with anaemia only and no colorectal symptoms. Finally, CRC cases were seen in both microcytic and normocytic groups with or without low ferritin. There is no significant difference in the yield of CRC between fast track patients with microcytic and normocytic anaemia. This study provides insufficient evidence to support awaiting confirmation of IDA in fast track patients with normocytic anaemia prior to requesting bowel investigations.

  5. The ATLAS Fast Tracker and Tracking at the High-Luminosity LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00236423; The ATLAS collaboration

    2016-01-01

    The LHC’s increase in centre of mass energy and luminosity in 2015 makes controlling trigger rates with high efficiency challenging. The ATLAS Fast TracKer (FTK) is a hardware processor built to reconstruct tracks at a rate of up to 100 kHz and provide them to the high level trigger. The FTK reconstructs tracks by matching incoming detector hits with pre-defined track patterns stored in associative memory on custom ASICs. Inner detector hits are fit to these track patterns using modern FPGAs. These procedings describe the electronics system used for the FTK’s massive parallelization. An overview of the installation, commissioning and running of the system is given. The ATLAS upgrades planned to enable tracking at the High Luminosity LHC are also discussed.

  6. Market potential and growth areas of public utilities. Electromobility; Marktpotenzial und Wachstumsfeld fuer Energieversorger. Elektromobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Lueers, Thomas [Homburg und Partner, Mannheim (Germany). Kompetenzzentrum Energy/Utilities; Hanitsch, Kai [Homburg und Partner, Mannheim (Germany)

    2010-11-15

    The automobile industry is in full transition. All manufacturers are working on new drive concepts that meet the increasingly rigid emission specifications. Electric power is favoured as an energy source for the future, which gets public utilities interested in teh attractivity of this growing market. Accurate knowledge of the market potential generated by electromobility provides a basis for a targeted and successful marketing strategy. (orig.)

  7. Electromobility. More than just substituting electricity for motor fuels; Elektromobilitaet. Mehr als Strom statt Benzin

    Energy Technology Data Exchange (ETDEWEB)

    Hebling, Christopher [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg (Germany). Abt. Energietechnik

    2010-09-15

    By 2020, one million electric-powered vehicles are to run on German roads. The reasons are simple: Oil reserves are limited, and there seems to be no way to stop the impending global climate change. Electromobility is not just a substitution of electric power for gasoline; there is much more to it than a replacement for the gasoline engine to which consumers are accustomed. (orig.)

  8. Fostering and sustaining innovation in a Fast Growing Agile Company

    OpenAIRE

    Moe, NilsBrede; Barney, Sebastian; Aurum, Aybüe; Khurum, Mahvish; Wohlin, Claes; Barney, Hamish; Gorschek, Tony; Winata, Martha

    2012-01-01

    Sustaining innovation in a fast growing software development company is difficult. As organisations grow, peoples' focus often changes from the big picture of the product being developed to the specific role they fill. This paper presents two complementary approaches that were successfully used to support continued developer-driven innovation in a rapidly growing Australian agile software development company. The method "FedEx TM Day" gives developers one day to showcase a proof of concept th...

  9. Short Hospital Stay after Laparoscopic Colorectal Surgery without Fast Track

    Directory of Open Access Journals (Sweden)

    Stefan K. Burgdorf

    2012-01-01

    Full Text Available Purpose. Short hospital stay and equal or reduced complication rates have been demonstrated after fast track open colonic surgery. However, fast track principles of perioperative care can be difficult to implement and often require increased nursing staff because of more concentrated nursing tasks during the shorter hospital stay. Specific data on nursing requirements after laparoscopic surgery are lacking. The purpose of the study was to evaluate the effect of operative technique (open versus laparoscopic operation, but without changing nurse staffing or principles for peri- or postoperative care, that is, without implementing fast track principles, on length of stay after colorectal resection for cancer. Methods. Records of all patients operated for colorectal cancer from November 2004 to December 2008 in our department were reviewed. No specific patients were selected for laparoscopic repair, which was solely dependent on the presence of two specific surgeons at the same time. Thus, the patients were not selected for laparoscopic repair based on patient-related factors, but only on the simultaneous presence of two specific surgeons on the day of the operation. Results. Of a total of 540 included patients, 213 (39% were operated by a laparoscopic approach. The median hospital stay for patients with a primary anastomosis was significantly shorter after laparoscopic than after conventional open surgery (5 versus 8 days, while there was no difference in patients receiving a stoma (10 versus 10 days, ns, with no changes in the perioperative care regimens. Furthermore there were significant lower blood loss (50 versus 200 mL, and lower complication rate (21% versus 32%, in the laparoscopic group. Conclusion. Implementing laparoscopic colorectal surgery in our department resulted in shorter hospital stay without using fast track principles for peri- and postoperative care in patients not receiving a stoma during the operation. Consequently, we

  10. [Laparoscopic "fast-track" sigmoidectomy for diverticulitis disease in Germany. Results of a prospective quality assurance program].

    Science.gov (United States)

    Tsilimparis, N; Haase, O; Wendling, P; Kipfmüller, K; Schmid, M; Engemann, R; Schwenk, W

    2010-09-01

    The natural course of sigmoid colon diverticulitis during conservative therapy and the assessment of the perioperative morbidity after sigmoid colon resection are differently evaluated by surgeons and gastroenterologists. The "fast-track" rehabilitation accelerates the reconvalescence and reduces the rate of postoperative general complications after colorectal surgery. The results of the laparoscopic "Fast-track" sigmoidectomy should be examined within a quality assurance program to better evaluate the perioperative risks following surgical management of diverticulitis. A prospective data collection within the voluntary quality assurance program "fast-track" Kolon II was performed. All participating clinics agreed on a multimodal, evidence-based standard perioperative treatment in terms of a "fast-track" rehabilitation for elective operations for sigmoid diverticulitis. Data from 846 patients undergoing laparoscopic "fast-track" sigmoid colon resection in 23 surgical departments in Germany were collected and evaluated. The mean age of the patients was 63 years (range 23 - 91). 203 patients (24 %) had severe co-morbidities (ASA classification III - IV). A conversion to conventional open surgery was necessary in 51 cases (6 %). Complications occurred in 93 patients (11 %). 76 patients suffered a surgical complication (8.9 %) and 32 patients (3.8 %) a general complication. Two patients died postoperatively due to multi-organ failure following anastomotic leaks. The patients took solid food in median on day 1 after surgery (range, 0 - 5) and passed stool on day 2 (range, 0 - 22). Predefined discharge criteria (free of pain on oral medication, normal oral feeding, stool) were met on day 4 (range, 1 - 58) and the patients were discharged on day 7 (range, 3 - 72). The 30-day re-admission rate was 3.9 %. Patients undergoing laparoscopic "fast-track" sigmoidectomy had a low rate of general complications and had a rapid reconvalescence with a short postoperative in

  11. Laparoscopic surgery contributes more to nutritional and immunologic recovery than fast-track care in colorectal cancer.

    Science.gov (United States)

    Xu, Dong; Li, Jun; Song, Yongmao; Zhou, Jiaojiao; Sun, Fangfang; Wang, Jianwei; Duan, Yin; Hu, Yeting; Liu, Yue; Wang, Xiaochen; Sun, Lifeng; Wu, Linshan; Ding, Kefeng

    2015-02-04

    Many clinical trials had repeatedly shown that fast-track perioperative care and laparoscopic surgery are both preferred in the treatment of colorectal cancer. But few studies were designed to explore the diverse biochemical impacts of the two counterparts on human immunologic and nutritional status. Ninety-two cases of colorectal cancer patients meeting the inclusion criteria were randomized to four groups: laparoscopy with fast-track treatment (LAFT); open surgery with fast-track treatment (OSFT); laparoscopy with conventional treatment (LAC); open surgery with conventional treatment (OSC). Peripheral blood tests including nutritional factors (albumin, prealbumin, and transferrin), humoral immunologic factors (IgG, IgM, and IgA), and cellular immunologic factors (T and NK cells) were evaluated. Blood samples were collected preoperatively (baseline) and 12 and 96 h after surgery (indicated as POH12 and POH96, respectively). Albumin, transferrin, prealbumin, and IgG levels were the highest in the LAFT group for both POH12 and POH96 time intervals. Repeated measures (two-way ANOVA) indicated that the difference of albumin, transferrin, and IgG level were attributed to surgery type (P  0.05). Only in the laparoscopy-included groups, the relative albumin and IgG levels of POH96 were obviously higher than that of POH12. Laparoscopic surgery accelerated postoperative nutrition and immune levels rising again while fast-track treatment retarded the drop of postoperative nutrition and immune levels. Laparoscopic surgery might play a more important role than fast-track treatment in the earlier postoperative recovery of nutritional and immunologic status. Combined laparoscopic surgery with fast-track treatment provided best postoperative recovery of nutrition and immune status. These results should be further compared with the clinical outcomes of our FTMDT trial (clinicaltrials.gov: NCT01080547).

  12. Fast Track Open Partial Nephrectomy: Reduced Postoperative Length of Stay with a Goal-Directed Pathway Does Not Compromise Outcome

    Directory of Open Access Journals (Sweden)

    Bilal Chughtai

    2008-01-01

    Full Text Available Introduction. The aim of this study is to examine the feasibility of reducing postoperative hospital stay following open partial nephrectomy through the implementation of a goal directed clinical management pathway. Materials and Methods. A fast track clinical pathway for open partial nephrectomy was introduced in July 2006 at our institution. The pathway has daily goals and targets discharge for all patients on the 3rd postoperative day (POD. Defined goals are (1 ambulation and liquid diet on the evening of the operative day; (2 out of bed (OOB at least 4 times on POD 1; (3 removal of Foley catheter on the morning of POD 2; (4 removal of Jackson Pratt drain on the afternoon of POD 2; (4 discharge to home on POD 3. Patients and family are instructed in the fast track protocol preoperatively. Demographic data, tumor size, length of stay, and complications were captured in a prospective database, and compared to a control group managed consecutively immediately preceding the institution of the fast track clinical pathway. Results. Data on 33 consecutive patients managed on the fast track clinical pathway was compared to that of 25 control patients. Twenty two (61% out of 36 fast track patients and 4 (16% out of 25 control patients achieved discharge on POD 3. Overall, fast track patients had a shorter hospital stay than controls (median, 3 versus 4 days; P = .012. Age (median, 55 versus 57 years, tumor size (median, 2.5 versus 2.5 cm, readmission within 30 days (5.5% versus 5.1%, and complications (10.2% versus 13.8% were similar in the fast track patients and control, respectively. Conclusions. In the present series, a fast track clinical pathway after open partial nephrectomy reduced the postoperative length of hospital stay and did not appear to increase the postoperative complication rate.

  13. Hardware-based Tracking at Trigger Level for ATLAS: The Fast TracKer (FTK) Project

    CERN Document Server

    Gramling, Johanna; The ATLAS collaboration

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer (FTK) is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level 1 trigger (at a maximum rate of 100 kHz) the FTK receives data from the 80 million channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware- based track reconstruction, using associative memory (AM) that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. Narrow roads permit a fast track fitting but need many patterns stored in the AM to ensure...

  14. Research on Precision Tracking on Fast Steering Mirror and Control Strategy

    Science.gov (United States)

    Di, Lin; Yi-ming, Wu; Fan, Zhu

    2018-01-01

    Fast steering mirror is a device used for controlling the beam direction precisely. Due to the short travel of the push-pull FSM, a compound fast steering mirror system driven by both limited-angle voice coil motor and push-pull FSM together is proposed. In the compound FSM system, limited-angle voice coil motor quickly swings at wide angle, while the push-pull FSM do high frequency movement in a small range, which provides the system with the high bandwidth and long travel. In the control strategy, the method of combining feed-forward control in Kalman filtering with auto-disturbance rejection control is used to improve trajectory tracking accuracy. The simulation result shows that tracking accuracy measured by the compound method can be improved by more than 5 times than that of the conventional PID.

  15. Patient-reported outcome after fast-track hip arthroplasty: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Hansen Torben B

    2010-11-01

    Full Text Available Abstract Background A fast-track intervention with a short preoperative optimization period and short postoperative hospitalization has a potential for reduced convalescence and thereby a reduced need for postoperative rehabilitation. The purpose of this study was to describe patient-related outcomes, the need for additional rehabilitation after a fast-track total hip arthroplasty (THA, and the association between generic and disease specific outcomes. Methods The study consisted of 196 consecutive patients of which none received additional rehabilitation beyond an instructional exercise plan at discharge, which was adjusted at one in-patient visit. The patients filled in 3 questionnaires to measure health-related quality-of-life (HRQOL and hip specific function (EQ-5 D, SF36, and Harris Hip Score (HHS at 2 time points pre- and 2 time points postoperatively. The observed results were compared to normative population data for EQ-5 D, SF36, and HHS. Results 3-months postoperatively patients had reached a HRQOL level of 0.84 (SD, 0.14, which was similar to the population norm (P = 0.33, whereas they exceeded the population norm at 12 months postoperatively (P P P = 0.35. For HHS, patients never reached the population norm within 12 months postoperatively. Generic and disease specific outcomes were strongly associated. Conclusions If HRQOL is considered the primary outcome after THA, the need for additional postoperative rehabilitation for all THA patients following a fast-track intervention is questionable. However, a pre- or early postoperative physical intervention seems relevant if the PF of the population norm should be reached at 3 months. If disease specific outcome is considered the primary outcome after fast-track THA, clear goals for the rehabilitation must be established before patient selection, intervention type and timing of intervention can be made.

  16. FAST: A fully asynchronous and status-tracking pattern for geoprocessing services orchestration

    Science.gov (United States)

    Wu, Huayi; You, Lan; Gui, Zhipeng; Gao, Shuang; Li, Zhenqiang; Yu, Jingmin

    2014-09-01

    Geoprocessing service orchestration (GSO) provides a unified and flexible way to implement cross-application, long-lived, and multi-step geoprocessing service workflows by coordinating geoprocessing services collaboratively. Usually, geoprocessing services and geoprocessing service workflows are data and/or computing intensive. The intensity feature may make the execution process of a workflow time-consuming. Since it initials an execution request without blocking other interactions on the client side, an asynchronous mechanism is especially appropriate for GSO workflows. Many critical problems remain to be solved in existing asynchronous patterns for GSO including difficulties in improving performance, status tracking, and clarifying the workflow structure. These problems are a challenge when orchestrating performance efficiency, making statuses instantly available, and constructing clearly structured GSO workflows. A Fully Asynchronous and Status-Tracking (FAST) pattern that adopts asynchronous interactions throughout the whole communication tier of a workflow is proposed for GSO. The proposed FAST pattern includes a mechanism that actively pushes the latest status to clients instantly and economically. An independent proxy was designed to isolate the status tracking logic from the geoprocessing business logic, which assists the formation of a clear GSO workflow structure. A workflow was implemented in the FAST pattern to simulate the flooding process in the Poyang Lake region. Experimental results show that the proposed FAST pattern can efficiently tackle data/computing intensive geoprocessing tasks. The performance of all collaborative partners was improved due to the asynchronous mechanism throughout communication tier. A status-tracking mechanism helps users retrieve the latest running status of a GSO workflow in an efficient and instant way. The clear structure of the GSO workflow lowers the barriers for geospatial domain experts and model designers to

  17. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial

    Directory of Open Access Journals (Sweden)

    Swart Annemiek

    2006-11-01

    Full Text Available Abstract Background Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay. The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst track multimodal management versus standard care was conceived to determine whether laparoscopic surgery, fast track perioperative care or a combination of both is to be preferred over open surgery with standard care in patients having segmental colectomy for malignant disease. Methods/design The LAFA-trial is a double blinded, multicenter trial with a 2 × 2 balanced factorial design. Patients eligible for segmental colectomy for malignant colorectal disease i.e. right and left colectomy and anterior resection will be randomized to either open or laparoscopic colectomy, and to either standard care or the fast track program. This factorial design produces four treatment groups; open colectomy with standard care (a, open colectomy with fast track program (b, laparoscopic colectomy with standard care (c, and laparoscopic surgery with fast track program (d. Primary outcome parameter is postoperative hospital length of stay including readmission within 30 days. Secondary outcome parameters are quality of life two and four weeks after surgery, overall hospital costs, morbidity, patient satisfaction and readmission rate. Based on a mean postoperative hospital stay of 9 +/- 2.5 days a group size of 400 patients (100 each arm can reliably detect a minimum difference of 1 day between the four arms (alfa = 0.95, beta = 0.8. With 100 patients in each arm a difference of 10% in subscales of the Short Form 36 (SF-36 questionnaire and social functioning can be detected. Discussion The LAFA-trial is a randomized controlled multicenter trial that will provide evidence on the merits of fast track perioperative care and laparoscopic colorectal surgery in

  18. IAEA Technical Meeting on Innovative Heat Exchanger and Steam Generator Designs for Fast Reactors. Working Material

    International Nuclear Information System (INIS)

    2011-01-01

    The IAEA, within the framework of its Nuclear Energy Department’s Technical Working Group on Fast Reactors (TWG-FR), assists Member States activities in fast reactors technology development areas by providing an umbrella for information exchange [topical Technical Meetings (TMs), Workshops and large Conferences] and collaborative R&D [Coordinated Research Projects (CRPs)]. The Technical meeting on “Innovative Heat Exchanger and Steam Generator Designs for Fast Reactors” was held from 21 – 22 December 2011 in Vienna, addressing Member States’ expressed needs of information exchange in the field of advanced fast reactor design features, with particular attention to innovative heat exchangers and steam generators. The Objective of the TM is to provide a global forum for in-depth information exchange and discussion on the most advanced concepts of heat exchangers and steam generators for fast reactors. More specifically, the objectives are: · Review of the status of advanced fast reactor development activities with special emphasis on design and performance of heat exchangers and steam generators; · Discuss requirements for innovative heat exchangers and steam generators; · Present results of studies and conceptual designs for innovative heat exchangers and steam generators; · Provide recommendations for international collaboration under the IAEA aegis. The meeting agenda of the meeting is in Annex I

  19. Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator

    International Nuclear Information System (INIS)

    Castillo, F.; Espinosa, G.; Golzarri, J.I.; Osorio, D.; Rangel, J.; Reyes, P.G.; Herrera, J.J.E.

    2013-01-01

    The chemical etching parameters (etching time, temperature, normality of etchant, etc.) for the use of CR-39 (allyl diglycol carbonate – Lantrack ® ) as a fast neutron dosimeter have been optimized. The CR-39 chips, placed under a 1.5 mm polyethylene radiator, were exposed for calibration to an 241 Am-Be source at different time intervals for a given neutron fluence. After several chemical etching processes of the detectors with different conditions, the optimum characteristics for the chemical etching were found at 6N KOH solution, 60 ± 1 °C, for 12 h. An accurate relationship between the dose and fluence calculations was obtained as a function of the track density. - Highlights: ► Optimum etching time for fast neutron irradiated CR-39 track detectors is found. ► Relationship between dose and fluence obtained as a function of the track density. ► Results are consistent with those reported elsewhere, and extend the dose range

  20. David Bowie and the Art of Slow Innovation: A Fast-Second Winner Strategy for Biotechnology and Precision Medicine Global Development.

    Science.gov (United States)

    Özdemir, Vural; Patrinos, George P

    2017-11-01

    Original ideas and innovation cannot always be ordered like a courier service and delivered fresh to our desk at 9 am. Yet, most creativity-based organizations, careers, and professions, science and biotechnology innovation included, emphasize the speed as the prevailing ideology. But a narrow focus on speed has several and overlooked shortcomings. For example, it does not offer the opportunity to draw from, and stitch together disparate concepts and practices for truly disruptive innovation. Preventing false starts, learning from others' or our own mistakes, and customizing innovations for local community needs are difficult in a speed-hungry innovation ecosystem. We introduce a new strategy, the Fast-Second Winner, specifically in relation to global development of biotechnologies and precision medicine. This à la carte global development strategy envisions a midstream entry into the innovation ecosystem. Moreover, we draw from the works of the late David Bowie who defied rigid classifications as an artist and prolific innovator, and introduce the concept and practice of slow innovation that bodes well with the Fast-Second Winner strategy. A type of slow innovation, the Fast-Second Winner is actually fast and sustainable in the long term, and efficient by reducing false starts in new precision medicine application contexts and geographies, learning from other innovators' failures, and shaping innovations for the local community needs. The establishment of Centers for Fast-Second Innovation (CFSIs), and their funding, for example, by crowdfunding and other innovative mechanisms, could be timely for omics and precision medicine global development. If precision medicine is about tailoring drug treatments and various health interventions to individuals, we suggest to start from tailoring new ideas, and focus not only on how much we innovate but also what and how we innovate. In principle, the Fast-Second Winner can be applied to omics and other biotechnology

  1. Avoiding ICU Admission by Using a Fast-Track Protocol Is Safe in Selected Adult-to-Adult Live Donor Liver Transplant Recipients

    Directory of Open Access Journals (Sweden)

    Juan Echeverri, MD

    2017-10-01

    Full Text Available Background. We evaluated patient characteristics of live donor liver transplant (LDLT recipients undergoing a fast-track protocol without intensive care unit (ICU admission versus LDLT patients receiving posttransplant ICU care. Methods. Of the 153 LDLT recipients, 46 patients were included in our fast-track protocol without ICU admission. Both, fast-tracked patients and ICU-admitted patients were compared regarding donor and patient characteristics, perioperative characteristics, and postoperative outcomes and complications. In a subgroup analysis, we compared fast-tracked patients with patients who were admitted in the ICU for less than 24 hours. Results. Fast-tracked versus ICU patients had a lower model for end-stage liver disease score (13 ± 4 vs 18 ± 7; P < 0.0001, lower preoperative bilirubin levels (51 ± 50 μmol/L vs 119.4 ± 137.3 μmol/L; P < 0.001, required fewer units of packed red blood cells (1.7 ± 1.78 vs 4.4 ± 4; P < 0.0001, and less fresh-frozen plasma (2.7 ± 2 vs 5.8 ± 5; P < 0.0001 during transplantation. Regarding postoperative outcomes, fast-tracked patients presented fewer bacterial infections within 30 days (6.5% [3] vs 29% [28]; P = 0.002, no episodes of pneumonia (0% vs 11.3% [11]; P = 0.02, and less biliary complications within the first year (6% [3] vs 26% [25]; P = 0.001. Also, fast-tracked patients had a shorter posttransplant hospital stay (10.8 ± 5 vs 21.3 ± 29; P = 0.002. In the subgroup analysis, fast-tracked vs ICU patients admitted for less than 24 hours had lower requirements of packed red blood cells (1.7 ± 1.78 vs 3.9 ± 4; P = 0.001 and fresh-frozen plasma (2.7 ± 2 vs 5.8 ± 4.5; P = 0.0001. Conclusions. Fast-track of selected patients after LDLT is safe and feasible. An objective score to perioperatively select LDLT recipients amenable to fast track is yet to be determined.

  2. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been s...... speculated that a decrease in LOS may be associated with an increase in readmissions in general, including risk of dislocation after total hip arthroplasty (THA) or manipulation after total knee arthroplasty (TKA)....

  3. [Shortened hospital stay for elective cesarean section after initiation of a fast-track program and midwifery home-care].

    Science.gov (United States)

    Gunnarsdottir, Johanna; Bjornsdottir, Thorbjörg Edda; Halldorsson, Thorhallur Ingi; Halldorsdottir, Gudrun; Geirsson, Reynir Tomas

    2011-07-01

    To audit whether hospital stay shortened without increasing readmissions after implementation of fast-track methodology for elective cesarean section and characterize what influences length of stay. A fast-track program was initiated in November 2008, with a one year clinical audit and satisfaction survey. Discharge criteria were predefined and midwife home visits included if discharge was within 48 hours. Hospital stay by parity for women with elective section for singleton pregnancy between 1.11. 2008 - 31.10. 2009 (n=213, fast-track 182) was compared to 2003 (n=199) and 2007 (n=183). Readmissions and outpatient visits 2007 and 2008-9 were counted. Reasons for longer stay were recorded in fast-track, and body mass index. Median hospital stay decreased significantly from 81 to 52 hours between 2007 and 2008-9. Readmissions were four in each period and outpatient visit rates similar. In 2008-9, 66% of all women were discharged within 48 hours. Women in the fast-track program were satisfied with early discharge. Hospital stay for parous women was shorter in 2007 compared to 2003, but unchanged for nulliparas. Parity had a minimal influence on length of stay in 2008-9, although nulliparous women ≤ 25 years were more likely to stay >48 hours. Body mass index did not correlate with length of stay. Pain was rarely the reason for a longer stay in the fast-track program and 90% were satisfied with pain-medication after discharge. Most healthy women can be discharged early after singleton birth by elective cesarean, without increasing readmissions.

  4. Subacute pain and function after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Østergaard; Gaarn-Larsen, L; Kristensen, B B

    2009-01-01

    In a well-defined fast-track setup for total hip and knee arthroplasty, with a multimodal analgesic regimen consisting of intra-operative local anaesthetic infiltration and oral celecoxib, gabapentin and paracetamol for 6 days postoperatively, we conducted a prospective, consecutive, observationa...

  5. Evaluation of a fast-track programme for patients undergoing liver resection

    DEFF Research Database (Denmark)

    Schultz, Nicolai A.; Larsen, Peter Nørgaard; Klarskov, Birthe Michaelsen

    2013-01-01

    BACKGROUND: Recent developments in perioperative pathophysiology and care have documented evidence-based, multimodal rehabilitation (fast-track) to hasten recovery and to decrease morbidity and hospital stay for several major surgical procedures. The aim of this study was to investigate the effect...

  6. The Fleet Application for Scheduling and Tracking (FAST) Management Website

    Science.gov (United States)

    Marrero-Perez, Radames J.

    2014-01-01

    The FAST application was designed to replace the paper and pen method of checking out and checking in GSA Vehicles at KSC. By innovating from a paper and pen based checkout system to a fully digital one, not only the resources wasted by printing the checkout forms have been reduced, but it also reduces significantly the time that users and fleet managers need to interact with the system as well as improving the record accuracy for each vehicle. The vehicle information is pulled from a centralized database server in the SPSDL. In an attempt to add a new feature to the FAST application, the author of this report (alongside the FAST developers) has been designing and developing the FAST Management Website. The GSA fleet managers had to rely on the FAST developers in order to add new vehicles, edit vehicles and previous transactions, or for generating vehicles reports. By providing an easy-to-use FAST Management Website portal, the GSA fleet managers are now able to easily move vehicles, edit records, and print reports.

  7. Fast Track Finding in the ILC's Silicon Detector, SiD01

    International Nuclear Information System (INIS)

    Baker, David E.

    2007-01-01

    A fast track finder is presented which, unlike its more efficient, more computationally costly O(n3) time counterparts, tracks particles in O(n) time (for n being the number of hits). Developed as a tool for processing data from the ILC's proposed SiD detector, development of this fast track finder began with that proposed by Pablo Yepes in 1996 and adjusted to accommodate the changes in geometry of the SiD detector. First, space within the detector is voxellated, with hits assigned to voxels according to their r, φ, and η coordinates. A hit on the outermost layer is selected, and a 'sample space' is built from the hits in the selected hit's surrounding voxels. The hit in the sample space with the smallest distance to the first is then selected, and the sample space recalculated for this hit. This process continues until the list of hits becomes large enough, at which point the helical circle in the x, y plane is conformally mapped to a line in the x', y' plane, and hits are chosen from the sample spaces of the previous fit by selecting the hits which fit a line to the previously selected points with the smallest χ 2 . Track finding terminates when the innermost layer has been reached or no hit in the sample space fits those previously selected to an acceptable χ 2 . Again, a hit on the outermost layer is selected and the process repeats until no assignable hits remain. The algorithm proved to be very efficient on artificial diagnostic events, such as one hundred muons scattered at momenta of 1 GeV/c to 10 GeV/c. Unfortunately, when tracking simulated events corresponding to actual physics, the track finder's efficiency decreased drastically (mostly due to signal noise), though future data cleaning programs could noticeably increase its efficiency on these events

  8. Fast track multi-discipline treatment (FTMDT trial versus conventional treatment in colorectal cancer--the design of a prospective randomized controlled study

    Directory of Open Access Journals (Sweden)

    Zhou Jiao-Jiao

    2011-11-01

    Full Text Available Abstract Background Laparoscopy-assisted surgery, fast-track perioperative treatment are both increasingly used in colorectal cancer treatment, for their short-time benefits of enhanced recovery and short hospital stays. However, the benefits of the integration of the Laparoscopy-assisted surgery, fast-track perioperative treatment, and even with the Xelox chemotherapy, are still unknown. In this study, the three treatments integration is defined as "Fast Track Multi-Discipline Treatment Model" for colorectal cancer and this model extends the benefits to the whole treatment process of colorectal cancer. The main purpose of the study is to explore the feasibility of "Fast Track Multi-Discipline Treatment" model in treatment of colorectal cancer. Methods The trial is a prospective randomized controlled study with 2 × 2 balanced factorial design. Patients eligible for the study will be randomized to 4 groups: (I Laparoscopic surgery with fast track perioperative treatment and Xelox chemotherapy; (II Open surgery with fast track perioperative treatment and Xelox chemotherapy; (III Laparoscopic surgery with conventional perioperative treatment and mFolfox6 chemotherapy; (IV Open surgery with conventional perioperative treatment and mFolfox6 chemotherapy. The primary endpoint of this study is the hospital stays. The secondary endpoints are the quality of life, chemotherapy related adverse events, surgical complications and hospitalization costs. Totally, 340 patients will be enrolled with 85 patients in each group. Conclusions The study initiates a new treatment model "Fast Track Multi-Discipline Treatment" for colorectal cancer, and will provide feasibility evidence on the new model "Fast Track Multi-Discipline Treatment" for patients with colorectal cancer. Trial registration ClinicalTrials.gov: NCT01080547

  9. Maintaining Unity - relatives in older patients' fast-track treatment programmes. A grounded theory study.

    Science.gov (United States)

    Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten

    2014-12-01

    To generate a substantive grounded theory of relatives' pattern of behaviour in older patients' fast-track treatment programmes during total hip or knee replacement. Fast-track treatment programmes are designed to make total hip and knee replacements more efficient through recovery improvements. The support of relatives during older patients' trajectory is important. However, knowledge is needed on the relatives' pattern of behaviour to strengthen their involvement in fast-track treatment programmes. We used a Glaserian grounded theory approach based on a systematic generation of theory from data to explain the latent pattern of behaviour of relatives. Data were collected from 2010-2011 in orthopaedic wards at two Danish university hospitals and consisted of 14 non-participant observations, 14 postobservational interviews and five interviews. Seven relatives of patients over 70 years of age participated. The constant comparative method was the guiding principle for simultaneous data collection, data analysis and coding, while theoretically sampling and writing memos. Maintaining Unity emerged as the relatives' pattern of behaviour through which they resolved their main concern: preventing the patients from feeling alone. The relatives resolved their main concern through three interchangeable behavioural modes: Protecting Mode, by providing loving and respectful support; Substituting Mode, with practical and cognitive support; and an Adapting Mode, by trying to fit in with the patients' and health professionals' requirements. The substantive theory of Maintaining Unity offers knowledge of relatives' strong desire to provide compassionate and loving support for the older patients during fast-track treatment programmes. © 2014 John Wiley & Sons Ltd.

  10. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty; a detailed observational cohort study

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  11. When is it optimal to delegate: the theory of fast-track authority

    Czech Academy of Sciences Publication Activity Database

    Celik, Levent; Karabay, B.; McLaren, J.

    2015-01-01

    Roč. 7, č. 3 (2015), s. 347-389 ISSN 1945-7669 Institutional support: RVO:67985998 Keywords : fast-track authority * free trade * protectionist rents Subject RIV: AH - Economics Impact factor: 1.359, year: 2015

  12. Role of patient characteristics for fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C.; Jacobsen, M; Søballe, Kjeld

    2013-01-01

    BACKGROUND: /st>Patient age and comorbidity have been found to increase the length of hospital stay (LOS), readmissions, and mortality after surgery, including in elective primary total hip arthroplasty (THA) and total knee arthroplasty (TKA). Whether the same applies in fast-track THA and TKA...

  13. National platform electromobility. Report of the second working group battery technology; Nationale Plattform Elektromobilitaet. Bericht der AG-2 Batterietechnologie

    Energy Technology Data Exchange (ETDEWEB)

    Lamm, Arnold [Daimler AG, Kirchheim unter Teck (Nabern) (Germany). Charakterisierung HV-Batteriesysteme; Schulz, Markus [Evonik Industries AG, Berlin (Germany). Konzernkoordination Elektromobilitaet

    2010-07-01

    The contribution under consideration reports on the first interim results of the working group ''Battery technology'' of the national platform electromobility. The progress report extends from general views over a competition analysis and roadmap up to activity planning in order to achieve the milestones. Subsequently, recommendations to the Federal Government are given.

  14. fastPACE Train-the-Trainer: A scalable new educational program to accelerate training in biomedical innovation, entrepreneurship, and commercialization.

    Science.gov (United States)

    Servoss, Jonathan; Chang, Connie; Fay, Jonathan; Lota, Kanchan Sehgal; Mashour, George A; Ward, Kevin R

    2017-10-01

    The Institute of Medicine recommended the advance of innovation and entrepreneurship training programs within the Clinical & Translational Science Award (CTSA) program; however, there remains a gap in adoption by CTSA institutes. The University of Michigan's Michigan Institute for Clinical & Health Research and Fast Forward Medical Innovation (FFMI) partnered to develop a pilot program designed to teach CTSA hubs how to implement innovation and entrepreneurship programs at their home institutions. The program provided a 2-day onsite training experience combined with observation of an ongoing course focused on providing biomedical innovation, commercialization and entrepreneurial training to a medical academician audience (FFMI fast PACE). All 9 participating CTSA institutes reported a greater connection to biomedical research commercialization resources. Six launched their own version of the FFMI fast PACE course or modified existing programs. Two reported greater collaboration with their technology transfer offices. The FFMI fast PACE course and training program may be suitable for CTSA hubs looking to enhance innovation and entrepreneurship within their institutions and across their innovation ecosystems.

  15. Fast track surgery at the University Teaching Hospital of Kigali: a ...

    African Journals Online (AJOL)

    Background: Fast Track Surgery is synonymous with Enhanced Recovery after Surgery. It was started in the 1990's initially for colorectal surgery, but later became applicable to other aspects of surgery. Its core elements include epidural or regional anaesthesia, perioperative fluid management, minimally invasive surgical ...

  16. Fast Compressive Tracking.

    Science.gov (United States)

    Zhang, Kaihua; Zhang, Lei; Yang, Ming-Hsuan

    2014-10-01

    It is a challenging task to develop effective and efficient appearance models for robust object tracking due to factors such as pose variation, illumination change, occlusion, and motion blur. Existing online tracking algorithms often update models with samples from observations in recent frames. Despite much success has been demonstrated, numerous issues remain to be addressed. First, while these adaptive appearance models are data-dependent, there does not exist sufficient amount of data for online algorithms to learn at the outset. Second, online tracking algorithms often encounter the drift problems. As a result of self-taught learning, misaligned samples are likely to be added and degrade the appearance models. In this paper, we propose a simple yet effective and efficient tracking algorithm with an appearance model based on features extracted from a multiscale image feature space with data-independent basis. The proposed appearance model employs non-adaptive random projections that preserve the structure of the image feature space of objects. A very sparse measurement matrix is constructed to efficiently extract the features for the appearance model. We compress sample images of the foreground target and the background using the same sparse measurement matrix. The tracking task is formulated as a binary classification via a naive Bayes classifier with online update in the compressed domain. A coarse-to-fine search strategy is adopted to further reduce the computational complexity in the detection procedure. The proposed compressive tracking algorithm runs in real-time and performs favorably against state-of-the-art methods on challenging sequences in terms of efficiency, accuracy and robustness.

  17. IAEA Technical Meeting on Innovative Heat Exchanger and Steam Generator Designs for Fast Reactors. Presentations

    International Nuclear Information System (INIS)

    2011-01-01

    The fast reactor, which can generate electricity and breed additional fissile material for future fuel stocks, is a resource that will be needed when economic uranium supplies for the thermal reactors diminish. Further, the fast-fission fuel cycle in which material is recycled (a basic requirement to meet sustainability criteria) offers the flexibility needed to contribute decisively towards solving the problem of growing “spent” fuel inventories by greatly reducing the volume, the heat load and the radiotoxic inventory of high-level wastes that must be disposed of in long-term geological repositories. This is a waste management option that will play an increasingly important role in the future, and help to ensure that nuclear energy remains a sustainable long-term option in the world’s overall energy mix. In recognition of the fast reactor’s importance for the sustainability of the nuclear option, currently there is worldwide renewed interest in fast reactor technology development, as indicated, e.g., by the outcome of the Generation IV International Forum (GIF) technology review, which concluded with 3 out of 6 innovative systems to be fast reactors (gas cooled fast reactor, sodium cooled fast reactor, and heavy liquid metal cooled fast reactor), plus a potential fast core for a 4th concept, the super-critical water reactor. Currently, fast reactor construction projects are ongoing in India (PFBR) and Russian Federation (BN-800), whilst in China the first experimental fast reactor (CEFR) is in the commissioning phase. Fast reactor programs are also carried out in Europe (in particular in France), Japan, Republic of Korea and the USA. The most important challenges for fast reactors are in the areas of cost competitiveness with respect to LWRs and other energy sources, enhanced safety, non-proliferation, and public acceptance. With the exception of this latter, these translate into technology development challenges, i.e. the development of advanced reactor

  18. LiTrack A Fast longitudinal phase space tracking code with graphical user interface

    CERN Document Server

    Emma, Paul

    2005-01-01

    Many linear accelerators, such as linac-based light sources and linear colliders, apply longitudinal phase space manipulations in their design, including electron bunch compression and wakefield-induced energy spread control. Several computer codes handle such issues, but most require detailed information on the transverse focusing lattice. In fact, in most linear accelerators, the transverse distributions do not significantly affect the longitudinal, and can be ignored initially. This allows the use of a fast 2D code to study longitudinal aspects without time-consuming considerations of the transverse focusing. LiTrack is based on a 15-year old code (same name) originally written by one of us (KB), which is now a MATLAB-based code with additional features, such as a graphical user interface and output plotting. The single-bunch tracking includes RF acceleration, bunch compression to 3rd order, geometric and resistive wakefields, aperture limits, synchrotron radiation, and flexible output plotting. The code w...

  19. [Effects of a nutritional intervention in a fast-track program for a colorectal cancer surgery: systematic review].

    Science.gov (United States)

    Wanden-Berghe, Carmina; Sanz-Valero, Javier; Arroyo-Sebastián, Antonio; Cheikh-Moussa, Kamila; Moya-Forcen, Pedro

    2016-07-19

    Introducción: Preoperative nutritional status (NS) has consequences on postoperative (POSTOP) recovery. Our aim was to systematically review the nutritional interventions (NI) in Fast-Track protocols for colorectal cancer surgery and assess morbidity-mortality and patient´s recovery. Systematic review of scientific literature after consulting bibliographic databases: Medline, The Cochrane Library, Scopus, Embase, Web of Science, Institute for Scientific Information, Latin American and Caribbean Health Sciences Literature, The Cumulative Index to Nursing and Allied Health Literature. MeSH Descriptors: "Colorectal Surgery", "Fast-Track", "Perioperative Care", "Nutrition Therapy" and "Enhanced recovery programme". Filters: "Humans", Adult (19+ years) and "Clinical Trial". Variables POSTOP outcomes: bowel recovery (BR), hospital stay (HS), complications and death. Selected studies, 27, had good or excellent methodological quality. From 25 to 597 patients were included. Aged between 16-94 years, men were predominant in 66.6%. NS was evaluated in 13 studies; 7 by Body Mass Index while one by Subjective Global Assessment. One presented POSTOP data. Fast-Track groups had solids, liquids or supplements (SS) in prior 2-8 hours. SS were high in carbohydrates, immune-nutrients and non-residue. Free liquids, solids and SS intake was allowed in POSTOP. Half traditional groups fasted between 3-12 hours and resumed POSTOP food intake progressively. Fast-Track groups had early BR (p Nutritional status must be assessed for a higher acknowledgement of NI impact.

  20. Fast Track Extubation In Adult Patients On Pump Open Heart Surgery At A Tertiary Care Hospital.

    Science.gov (United States)

    Akhtar, Mohammad Irfan; Sharif, Hasanat; Hamid, Mohammad; Samad, Khalid; Khan, Fazal Hameed

    2016-01-01

    Fast-track cardiac surgery programs have been established as the standard of cardiac surgical care. Studies have shown that early extubation in elective cardiac surgery patients, including coronary and non-coronary open-heart surgery patients does not increase perioperative morbidity and mortality. The objective of this observational study was to determine the success and failure profile of fast track extubation (FTE) practice in adult open-heart surgical patients. The study was conducted at cardiac operating room and Cardiac Intensive Care Unit (CICU) of a tertiary care hospital for a period of nine months, i.e., from Oct 2014 to June-2015. All on pump elective adult cardiac surgery patients including isolated CABG, isolated Valve replacements, combined procedures and aortic root replacements were enrolled in the study. Standardized anesthetic technique was adopted. Surgical and bypass techniques were tailored according to the procedure. Success of Fast track extubation was defined as extubation within 6 hours of arrival in CICU. A total of 290 patients were recruited. The average age of the patients was 56.3±10.5 years. There were 77.6% male and 22.4% female patients. Overall success rate was 51.9% and failure rate was 48.1%. The peri-operative renal insufficiency, cross clamp time and CICU stay (hours) were significantly lower in success group. Re-intubation rate was 0.74%. The perioperative parameters were significantly better in success group and the safety was also demonstrated in the patients who were fast tracked successfully. To implement the practice in its full capacity and benefit, a fast track protocol needs to be devised to standardize the current practices and to disseminate the strategy among junior anaesthesiologists, perfusionists and nursing staff.

  1. Implementing large scale fast track diagnostics in a comprehensive cancer center, pre- and post-measurement data.

    Science.gov (United States)

    van Harten, W H; Goedbloed, N; Boekhout, A H; Heintzbergen, S

    2018-02-07

    In general, patients with a cancer suspicion visit the hospital multiple times before diagnosis is completed. Using various "operations management" techniques a few fast track diagnostic services were implemented in the Netherlands Cancer Institute (NKI) in 2006. Growing patient numbers and increasing process complexity, led to diminished service levels. To decrease the amount of patient visits and to extend these services beyond the (obvious) breast cancer services, fast track diagnostics is now implemented for all 18 cancer types that present with a frequency of minimally one per week. The throughput time (first visit to diagnosis conversation) was measured before, and after implementation of fast track diagnostics. The process was redesigned closely involving the multidisciplinary teams. In an eclectic approach elements from lean management, theory of constraints and mathematical analysis were used to organize slots per tumor type for MRI, CT, PET and echography. A post measurement was performed after 3 and 6 months. In pre measurement access time was calculated to be 10 to 15 workdays, mean throughput time was 6.0 workdays. It proved possible to design the process of 18 tumors as a fast track, of which 7 as "one stop shop" (diagnosis completed in one visit). Involvement of clinical- and board leadership, massive communication efforts and commitment of physicians to reschedule their work proved decisive. After 3 and 6 months of implementation, the mean access time was 8.2 and 8.7 workdays respectively and mean throughput time was 3.4 and 3.3 workdays respectively. Throughput- and access time were considerably shortened after implementation of fast track diagnostics for 18 cancer types. The involvement of physicians in reorganizing their work and rapid responding to their needs during the implementation phase were a crucial success factor.

  2. Fast track diagnosis as a means of reducing diagnostic delay in cancer

    DEFF Research Database (Denmark)

    Larsen, Mette Bach; Vedsted, Peter; Olesen, Frede

    of cancer and expanded services to the general practitioners. Objective: To investigate the diagnostic delay of cancer, patient and provider satisfaction and health economic aspects in two Danish regions with special emphasis on the possible benefits of fast track diagnosis. Methods: The study......Background: Denmark has the highest morbidity and mortality from cancer in Western Europe, and studies suggest that Danish cancer patients are diagnosed at a later stage than patients in the other Nordic countries. To address this issue a Danish hospital has introduced fast track diagnosis...... will be designed as a cross-sectional study with the construction of a clinical database of all incident cancers in two Danish regions within a year (12,000 patients). Data will be collected from general practitioners, patients and national registers. In the first part of the analysis the general variation...

  3. VISION: a Versatile and Innovative SIlicOn tracking system

    CERN Document Server

    Lietti, Daniela; Vallazza, Erik

    This thesis work focuses on the study of the performance of different tracking and profilometry systems (the so-called INSULAB, INSUbria LABoratory, and VISION, Versatile and Innovative SIlicON, Telescopes) used in the last years by the NTA-HCCC, the COHERENT (COHERENT effects in crystals for the physics of accelerators), ICE-RAD (Interaction in Crystals for Emission of RADiation) and CHANEL (CHAnneling of NEgative Leptons) experiments, four collaborations of the INFN (Istituto Nazionale di Fisica Nucleare) dedicated to the research in the crystals physics field.

  4. Effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation

    Directory of Open Access Journals (Sweden)

    Xing-Tao Cai

    2016-01-01

    Full Text Available Objective: To study the effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation. Methods: Sixty patients with rheumatic heart disease undergoing heart valve surgery were randomly divided into the fast track group (n=30 and conventional group (n=30. Then myocardial injury indicators, mitochondrial oxidative stress indicators, inflammation indicators and nerverelated peptides of both groups were analyzed. Results: cTnI contents at T2-T4 points in time of both groups showed an increasing trend and the increasing trend of fast track group was weaker than that of conventional group; SOD contents as well as mitochondrial tristate respiratory function, respiratory control ratios and phosphorus oxygen ratios in myocardial tissue of fast track group were higher than those of conventional group, and MDA contents was lower than those of conventional group; plasma TNF-α, IL-6, IL-8, NSE, S100β and Aβ contents of fast track group were lower than those of conventional group. Conclusions: Fasttrack cardiac anesthesia can protect myocardial cells, reduce mitochondrial oxidative stress, relieve inflammation and improve nerve function; it is an ideal anesthesia method for cardiac operation.

  5. National platform electromobility. Interim report of the working group 3 Load infrastructure and rid integration; Nationale Plattform Elektromobilitaet. Zwischenbericht der Arbeitsgruppe 3 Lade-Infrastruktur und Netzintegration

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Stefan [E.ON AG, Duesseldorf (Germany). Political Affairs and Communications Energy Mix, Environment, Efficiency; Ledwon, Martin [Siemens AG, Berlin (Germany). Government Affairs

    2010-07-01

    The contribution under consideration reports on the first intermediate results of the working group 3 ''Load infrastructure and grid integration'' of the national platform electromobility. Next to the representation of the general objective of this working group, the following aspects are considered: (a) Electromobility in the field of tension between the power supply system and renewable production; (b) Possible network loads due to the integration of electrically powered vehicles; (c) Requirements concerning the load infrastructure; (d) Technology development of the load point; (e) Potentials by the integration of electrical mobiles into the Smart Grid; (f) Research and Development roadmap. This contribution finishes with a presentation of a concrete conversion plan for the demand of infrastructure.

  6. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective, descrip......OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery......, except for hip pain. The average loss in knee-extension strength after surgery (32%, P = .01) did not correlate with increased thigh circumference (6%, P

  7. Anesthetic and adjunctive drugs for fast-track surgery.

    Science.gov (United States)

    Baldini, G; Carli, F

    2009-08-01

    With the changes in health care dictated by economic pressure, there has been a realization that hospital stay could be shortened without compromising quality of care. Advances in surgical technology and anesthetic drugs have made an impact in the way perioperative care is delivered with some emphasis on multidisciplinary approach. From the expansion of ambulatory care, lessons were learnt how to apply same concepts to major surgery with the understanding that interventions to attenuate the surgical stress would facilitate the return to "baseline". Beside minimal invasive approach to surgery, anesthesia interventions are arranged with the intent to decrease the negative effects of surgical stress and pain, to minimize the side effects of drugs and at the same time to facilitate the recuperation which follows after surgery. Fast-track or accelerated care encompasses many aspects of anesthesia care, not only preoperative preparation and prehabilitation, but intraoperative attenuation of surgical stress and postoperative rehabilitation. The anesthesiologist is part of this team with the specific mission to use medications and techniques which have the least side effects on organ functions, provide analgesia which in turn facilitates the intake of food and mobilization out of bed. This chapter has been conceived with the intention to direct the clinician towards procedure-specific protocols where the choice of medications and techniques is based on published evidence. The success of implementing fast-track depends more on dynamic harmony amongst the various participants (surgeons, anesthesiologists, nurses, nutrtionists, physiotherapists) than on reaching an optimum level of excellence at each separate organization level.

  8. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking

    DEFF Research Database (Denmark)

    Ravkilde, Thomas; Keall, Paul J.; Grau, Cai

    2014-01-01

    of the algorithm for reconstruction of dose and motion-induced dose errors throughout the tracking and non-tracking beam deliveries was quantified. Doses were reconstructed with a mean dose difference relative to the measurements of -0.5% (5.5% standard deviation) for cumulative dose. More importantly, the root...... validate a simple model for fast motion-including dose error reconstruction applicable to intrafractional QA of MLC tracking treatments of moving targets. MLC tracking experiments were performed on a standard linear accelerator with prototype MLC tracking software guided by an electromagnetic transponder......-mean-square deviation between reconstructed and measured motion-induced 3%/3 mm γ failure rates (dose error) was 2.6%. The mean computation time for each calculation of dose and dose error was 295 ms. The motion-including dose reconstruction allows accurate temporal and spatial pinpointing of errors in absorbed dose...

  9. Readmission rates after a planned hospital stay of 2 versus 3 days in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Andersen, Jens; Hjort-Jakobsen, Dorthe; Christiansen, P. S.

    2007-01-01

    BACKGROUND: Initial programmes of fast-track open colonic surgery with a planned 2-day postoperative hospital stay have had a high readmission rate (about 20 per cent). The aim of this large, consecutive series was to compare readmission rates after a fast-track open colonic surgery programme....... There was no difference in type and incidence of morbidity between the two periods. CONCLUSION: Readmission after fast-track open colonic resection was reduced by planning discharge 3 instead of 2 days after surgery, with the same discharge criteria. Copyright (c) 2007 British Journal of Surgery Society Ltd. Published...... from August 2004. All patients were examined 8 and 30 days after surgery. RESULTS: Readmission rates fell from 20.1 per cent in 408 patients with a planned 2-day hospital stay (period 1) to 11.3 per cent in 133 patients with a planned 3-day hospital stay (period 2) (P

  10. Families' Divided: The place of the Family in Zimbabwe's Fast Track ...

    African Journals Online (AJOL)

    The political history and the political economy continue to mould the quality of life for most families in significant ways. Human beings have always lived in families from the beginning of time. The family is a pillar of society as it influences the way society is structured, organized and functions, yet the Fast Track Land Reform ...

  11. When is it optimal to delegate: the theory of fast-track authority

    Czech Academy of Sciences Publication Activity Database

    Celik, Levent; Karabay, Bilgehan; McLaren, J.

    2015-01-01

    Roč. 7, č. 3 (2015), s. 347-389 ISSN 1945-7669 R&D Projects: GA ČR(CZ) GAP402/12/0666 Institutional support: PRVOUK-P23 Keywords : fast-track authority * free trade * protectionist rents Subject RIV: AH - Economics Impact factor: 1.359, year: 2015

  12. How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?

    Science.gov (United States)

    Sorensen, Lucy C; Dodge, Kenneth A

    2016-01-01

    Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how-that is, through which developmental pathways-these interventions work. This study assesses mechanisms by which the Fast Track project (n = 891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and general and mental health service utilization in adolescence through young adulthood (ages 12-20). A decomposition of treatment effects indicates that about a third of Fast Track's impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6-11), such as prosocial behavior, emotion regulation, and problem solving. These skills proved less valuable for the prevention of general and mental health problems. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  13. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  14. Influencing Factor of Postoperation Fast-track Recovery and in Hospital Cost after Lobctomy for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Jianhua SU

    2014-07-01

    Full Text Available Background and objective It is unknown that the postoperation fast-track recovery and in hospital cost of the lobectomy in lung cancer, we explored the influencing factor of postoperative fast-track recovery and in hospital cost after undergoing lobectomy for lung cancer. Methods We retrospectively reviewed the medical records of all patients (n=176 who underwent lobectomy for lung cancer between January 2010 and November 2011 by a thoracic surgeon. Results The hospital costs of video-assisted thoracic surgery (VATS lobectomy (47,308.21 ¥ is significantly higher than open lobectomy (45,664.31 ¥(P=0.007. The hospital costs of body mass index (BMI ≥ 24 kg/m2 (51,186.99 ¥ is significantly higher than BMI < 24 kg/m2 (41,701.64 ¥(P=0.032. The hospital stay of VATS lobectomy (5.70 d is significantly less than open lobectomy (7.10 d(P<0.001. Conclusion These findings indicate that preoperative pulmonary rehabilitation and VATS lobectomy is contributed to fast-track recovery for patients who undergo lobectomy, but increase the hospital costs.

  15. Indirect Effects of the Fast Track Intervention on Conduct Disorder Symptoms and Callous-Unemotional Traits: Distinct Pathways Involving Discipline and Warmth.

    Science.gov (United States)

    Pasalich, Dave S; Witkiewitz, Katie; McMahon, Robert J; Pinderhughes, Ellen E

    2016-04-01

    Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 to 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children's CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively.

  16. Cognitive dysfunction after fast-track hip and knee replacement.

    Science.gov (United States)

    Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben; Solgaard, Søren; Soballe, Kjeld; Rasmussen, Lars Simon

    2014-05-01

    Postoperative cognitive dysfunction (POCD) is reported to occur after major surgery in as many as 20% of patients, elderly patients may especially experience problems in the weeks and months after surgery. Recent studies vary greatly in methods of evaluation and diagnosis of POCD, and the pathogenic mechanisms are still unclear. We evaluated a large uniform cohort of elderly patients in a standardized approach, after major joint replacement surgery (total hip and knee replacement). Patients were in an optimized perioperative approach (fast track) with multimodal opioid-sparing analgesia, early mobilization, and short length of stay (LOS ≤3 days) and discharged to home. In a prospective multicenter study, we included 225 patients aged ≥60 years undergoing well-defined fast-track total hip or total knee replacement. Patients had neuropsychological testing preoperatively and 1 to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). Median LOS was 2 days (interquartile range 2-3). The incidence of POCD at 1 to 2 weeks was 9.1% (95% confidence interval [CI], 5.4%-13.1%) and 8.0% (95% CI, 4.5%-12.0%) at 3 months. There was no statistically significant difference between patients with and without early POCD, regarding pain, opioid use, sleep quality, or C-reactive protein response, although the CIs were wide. Patients with early POCD had a higher Mini Mental State Examination score preoperatively (difference in medians 0.5 [95% CI, -1.0% to 0.0%]; P = 0.034). If there was an association between early POCD and late POCD, the sample size was unfortunately too small to verify this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). The incidence of POCD early after total hip and knee replacement

  17. Interactive and automated systems for nuclear track measurements with applications to fast neutron dosimetry

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; McNeece, J.P.; Preston, C.C.; Ruddy, F.H.

    1983-12-01

    Interactive and automatic track measuring systems have been developed primarily for fast neutron dosimetry in and around reactors. The interactive system is used for proton recoil measurements in nuclear research emulsions and the automatic systems for counting fission fragment tracks in Muscovite mica. The status of these systems, along with illustrative applications, are presented, particularly with regard to their relationship to neutron personnel dosimetry. 16 references, 12 figures

  18. Fast Poisson Solvers for Self-Consistent Beam-Beam and Space-Charge Field Computation in Multiparticle Tracking Simulations

    CERN Document Server

    Florio, Adrien; Pieloni, Tatiana; CERN. Geneva. ATS Department

    2015-01-01

    We present two different approaches to solve the 2-dimensional electrostatic problem with open boundary conditions to be used in fast tracking codes for beam-beam and space charge simulations in high energy accelerators. We compare a fast multipoles method with a hybrid Poisson solver based on the fast Fourier transform and finite differences in polar coordinates. We show that the latter outperforms the first in terms of execution time and precision, allowing for a reduction of the noise in the tracking simulation. Furthermore the new algorithm is shown to scale linearly on parallel architectures with shared memory. We conclude by effectively replacing the HFMM by the new Poisson solver in the COMBI code.

  19. Network calculation in the low voltage network of the Düsseldorf utility company in respect of future electromobility

    OpenAIRE

    Sánchez García, Josefina

    2011-01-01

    Nowadays, everybody talk about Electromobility as something revolutionary but distant. Over recent years there has been a given social awareness about global warming due to greenhouse gases. People are aware of the need of changing in order to the current situation does not harm future generations. This has resulted in policies and laws at national and European level, in addition to global agreements like the Kyoto protocol, and more recently the Copenhagen summit. In particula...

  20. Fast regional readout CMOS Image Sensor for dynamic MLC tracking

    Science.gov (United States)

    Zin, H.; Harris, E.; Osmond, J.; Evans, P.

    2014-03-01

    Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ~400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.

  1. Fast regional readout CMOS image sensor for dynamic MLC tracking

    International Nuclear Information System (INIS)

    Zin, H; Harris, E; Osmond, J; Evans, P

    2014-01-01

    Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ∼400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.

  2. Postoperative Urinary Catheterization Thresholds of 500 versus 800 ml after Fast-track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars Stryhn; Hornum, Ulla Marianne; Troldborg, C.

    2016-01-01

    arthroplasty (THA) and total knee arthroplasty (TKA). METHODS: This was a randomized, controlled, open-label trial that included patients greater than or equal to 18 yr who underwent THA or TKA in three Danish, fast-track, orthopedic departments. Consenting patients were eligible if they were cooperative......BACKGROUND: No evidence-based threshold exists for postoperative urinary bladder catheterization. The authors hypothesized that a catheterization threshold of 800 ml was superior to 500 ml in reducing postoperative urinary catheterization and urological complications after fast-track total hip...

  3. Gas Cooled Fast Reactors: Recent advances and prospects

    International Nuclear Information System (INIS)

    Poette, C.; Guedeney, P.; Stainsby, R.; Mikityuk, K.; Knol, S.

    2013-01-01

    Gas Cooled Fast Reactors: Conclusion - GFR: an attractive longer term option allowing to combine Fast spectrum & Helium coolant benefits; • Innovative SiC fuel cladding solutions were found; • A first design confirming the encouraging potential of the reactor system Design improvements are nevertheless recommended and interesting tracks have been identified (core & system design, DHR system); • The GFR requires large R&D needs to confirm its potential (fuel & core materials, specific Helium technology); • ALLEGRO prototype studies are the first step and are drawing the R&D priorities

  4. A Midsize Tokamak As Fast Track To Burning Plasmas

    International Nuclear Information System (INIS)

    Mazzucato, E.

    2010-01-01

    This paper presents a midsize tokamak as a fast track to the investigation of burning plasmas. It is shown that it could reach large values of energy gain ((ge) 10) with only a modest improvement in confinement over the scaling that was used for designing the International Thermonuclear Experimental Reactor (ITER). This could be achieved by operating in a low plasma recycling regime that experiments indicate can lead to improved plasma confinement. The possibility of reaching the necessary conditions of low recycling using a more efficient magnetic divertor than those of present tokamaks is discussed.

  5. FAST TRACK SURGERY IN TOTAL KNEE ARTHROPLASTY - A REVIEW.

    Directory of Open Access Journals (Sweden)

    Pencho Kosev

    2015-08-01

    Full Text Available The number of orthopedic surgeons who are convinced in the need for significant changes in planned total knee arthroplasty (TKA is increasing slowly and steadily. A new approach to pain control has been developed over the past 10-15 years, and the introduction of techniques to reduce perioperative stress, and the use of minimally invasive surgical techniques can help limit postoperative complications and shorten recovery time. This type of optimization is regarded as Fast-track Care program, where improved healing process is particularly useful to comorbid patients.

  6. Variation in 'fast-track' referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites.

    Science.gov (United States)

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    In England, 'fast-track' (also known as 'two-week wait') general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. We examined data from 669 220 patients with 35 cancers diagnosed in 2006-2010 following either fast-track or 'routine' primary-to-secondary care referrals using 'Routes to Diagnosis' data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for 'alarm' symptoms are needed to improve diagnostic timeliness.

  7. Most patients regain prefracture basic mobility after hip fracture surgery in a fast-track programme

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Kehlet, Henrik

    2012-01-01

    Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity of the p......Treatment of patients with hip fracture has improved over the past decade. Still, some patients do not regain independent mobility within their primary hospital stay even if they follow a multimodal fast-track surgical programme. The aim of the present article was to examine the validity...... of the preliminary prefracture New Mobility Score (NMS), age and fracture type as independent predictors of in-hospital outcome after hip fracture surgery....

  8. The fast neutrons reactors, the sodium, the fuel cycle: evaluation of the knowledge, innovation potential and forecast

    International Nuclear Information System (INIS)

    Moreau, J.

    2002-01-01

    This document presents the study, the design and the construction of fast neutrons reactors, cooled with sodium. From this evaluation, it details the innovation possibilities of this sector in the sustainable development context of the nuclear energy. Chapter one presents the physical and physico-chemical properties of the sodium. Chapter two analyzes the properties of the fast cores and the sodium advantages. Chapter three analyzes the great contribution of the EFR project. Chapter four takes stock on the innovation possibilities. And before the conclusion, chapter five shows that the fast neutrons reactors allow the electric power production in agreement with a sustainable development. (A.L.B.)

  9. LiTrack: A Fast Longitudinal Phase Space Tracking Code with Graphical User Interface

    International Nuclear Information System (INIS)

    Bane, K.L.F.

    2005-01-01

    Linac-based light sources and linear colliders typically apply longitudinal phase space manipulations in their design, including electron bunch compression and wakefield-induced energy spread control. Several computer codes handle such issues, but most also require detailed information on the transverse focusing lattice. In fact, in most linear accelerators, the transverse distributions do not significantly affect the longitudinal, and can be ignored initially. This allows the use of a fast 2D code to study longitudinal aspects without time-consuming considerations of the transverse focusing. LiTrack is based on a 15-year old code (same name) originally written by one of us (KB), which is now a Matlab [1] code with additional features, such as graphical user interface, prompt output plotting, and functional call within a script. This single-bunch tracking code includes RF acceleration, bunch compression to 3rd order, geometric and resistive short-range wakefields, aperture limits, synchrotron radiation, and flexible output plotting. The code was used to design both the LCLS [2] and the SPPS [3] projects at SLAC and typically runs 10 5 particles in < 1 minute. We describe the features, show some examples, and provide free access to the code

  10. Safeguarding Self-Governance: A Grounded Theory of Older Patients’ Pattern of Behavior in Relation to their Relatives in Fast-track Programs

    DEFF Research Database (Denmark)

    Berthelsen, Connie B.; Frederiksen, Kirsten; Lindhardt Damsgaard, Tove

    2014-01-01

    Abstract The aim of this study was to generate a grounded theory of older patients’ pattern of behavior in relation to their relatives’ involvement in fast-track programs during total joint replacement. Sixteen patients were recruited in orthopedic wards. Data collection included 11 interviews......, shielding, distancing, and masking. Keywords: Fast-track program, grounded theory, older patients, relatives, total joint replacement.......-governance emerged in the analysis as the core category of our theory and pattern of behavior of the older patients in relation to their relatives. The older patients’ main concern was to complete the fast-track program while maintaining autonomy, which they resolved through four strategies of actions: embracing...

  11. Surgical Stress Response and Postoperative Immune Function After Laparoscopy or Open Surgery With Fast Track or Standard Perioperative Care A Randomized Trial

    NARCIS (Netherlands)

    Veenhof, A. A. F. A.; Vlug, M. S.; van der Pas, M. H. G. M.; Sietses, C.; van der Peet, D. L.; de Lange-de Klerk, E. S. M.; Bonjer, H. J.; Bemelman, W. A.; Cuesta, M. A.

    2012-01-01

    Objective: To evaluate the effect of laparoscopic or open colectomy with fast track or standard perioperative care on patient's immune status and stress response after surgery. Methods: Patients with nonmetastasized colon cancer were randomized to laparoscopic or open colectomy with fast track or

  12. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial).

    NARCIS (Netherlands)

    Wind, J.; Hofland, J.; Preckel, B.; Hollman, M.W.; Bossuyt, P.M.M.; Gouma, D.J.; Berge Henegouwen, M.I.; Fuhring, J.W.; Dejong, C.H.C.; Dam, R.M. van; Cuesta, M.A.; Noordhuis, A.; Jong, D. de; Zalingen, E. van; Engel, A.F.; Goei, T.H.; Stoppelaar, I.E. de; Tets, W.F. van; Wagensveld, B.A. van; Swart, A.; Elsen, M.J.L.J. van den; Gerhards, M.F.; Wit, L.Th. De; Siepel, M.A.M.; Geloven, A.A.W. van; Juttmann, J.-W.; Clevers, J.C.; Bemelman, W.A.

    2006-01-01

    BACKGROUND: Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay.The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst

  13. Perioperative strategy in colonic surgery; LAparoscopy and/or FAst track multimodal management versus standard care (LAFA trial)

    NARCIS (Netherlands)

    Wind, Jan; Hofland, Jan; Preckel, Benedikt; Hollmann, Markus W.; Bossuyt, Patrick M. M.; Gouma, Dirk J.; van Berge Henegouwen, Mark I.; Fuhring, Jan Willem; Dejong, Cornelis H. C.; van Dam, Ronald M.; Cuesta, Miguel A.; Noordhuis, Astrid; de Jong, Dick; van Zalingen, Edith; Engel, Alexander F.; Goei, T. Hauwy; de Stoppelaar, I. Erica; van Tets, Willem F.; van Wagensveld, Bart A.; Swart, Annemiek; van den Elsen, Maarten J. L. J.; Gerhards, Michael F.; de Wit, Laurens Th; Siepel, Muriel A. M.; van Geloven, Anna A. W.; Juttmann, Jan-Willem; Clevers, Wilfred; Bemelman, Willem A.

    2006-01-01

    BACKGROUND: Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay.The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst

  14. Fast-track program in laparoscopic liver surgery: Theory or fact?

    Science.gov (United States)

    Sánchez-Pérez, Belinda; Aranda-Narváez, José Manuel; Suárez-Muñoz, Miguel Angel; Eladel-Delfresno, Moises; Fernández-Aguilar, José Luis; Pérez-Daga, Jose Antonio; Pulido-Roa, Ysabel; Santoyo-Santoyo, Julio

    2012-11-27

    To analyze our results after the introduction of a fast-track (FT) program after laparoscopic liver surgery in our Hepatobiliarypancreatic Unit. All patients (43) undergoing laparoscopic liver surgery between March 2004 and March 2010 were included and divided into two consecutive groups: Control group (CG) from March 2004 until December 2006 with traditional perioperative cares (17 patients) and fast-track group (FTG) from January 2007 until March 2010 with FT program cares (26 patients). Primary endpoint was the influence of the program on the postoperative stay, the amount of re-admissions, morbidity and mortality. Secondarily we considered duration of surgery, use of drains, conversion to open surgery, intensive cares needs and transfusion. Both groups were homogeneous in age and sex. No differences in technique, time of surgery or conversion to open surgery were found, but more malignant diseases were operated in the FTG, and then transfusions were higher in FTG. Readmissions and morbidity were similar in both groups, without mortality. Postoperative stay was similar, with a median of 3 for CG vs 2.5 for FTG. However, the 80.8% of patients from FTG left the hospital within the first 3 d after surgery (58.8% for CG). The introduction of a FT program after laparoscopic liver surgery improves the recovery of patients without increasing complications or re-admissions, which leads to a reduction of the stay and costs.

  15. Mass tracking and material accounting in the Integral Fast Reactor (IFR)

    International Nuclear Information System (INIS)

    Orechwa, Y.; Adams, C.H.; White, A.M.

    1991-01-01

    The Integral Fast Reactor (IFR) is a generic advanced liquid metal cooled reactor concept being developed at Argonne National Laboratory (ANL). There are a number of technical features of the IFR which contribute to its potential as a next-generation reactor. These are associated with large safety margins with regard to off-normal events involving the heat transport system, and the use of metallic fuel which makes possible the utilization of innovative fuel cycle processes. The latter feature permits fuel cycle closure the compact, low-cost reprocessing facilities, collocated with the reactor plant. These primary features are being demonstrated in the facilities at ANL-West, utilizing Experimental Breeder Reactor 2 and the associated Fuel Cycle Facility (FCF) as an IFR prototype. The demonstration of this IFR prototype includes the design and implementation of the Mass-Tracking System (MTG). In this system, data from the operations of the FCF, including weights and batch-process parameters, are collected and maintained by the MTG running on distributed workstations. The components of the MTG System include: (1) an Oracle database manager with a Fortran interface, (2) a set of MTG ''Tasks'' which collect, manipulate and report data, (3) a set of MTG ''Terminal Sessions'' which provide some interactive control of the Tasks, and (4) a set of servers which manage the Tasks and which provide the communications link between the MTG System and Operator Control Stations, which control process equipment and monitoring devices within the FCF

  16. Fast covariance estimation for innovations computed from a spatial Gibbs point process

    DEFF Research Database (Denmark)

    Coeurjolly, Jean-Francois; Rubak, Ege

    In this paper, we derive an exact formula for the covariance of two innovations computed from a spatial Gibbs point process and suggest a fast method for estimating this covariance. We show how this methodology can be used to estimate the asymptotic covariance matrix of the maximum pseudo...

  17. Design of a 300-Watt Isolated Power Supply for Ultra-Fast Tracking Converters

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Ouyang, Ziwei; Petersen, Lars Press

    2015-01-01

    This paper presents the design of a medium-powerrating isolated power supply for ultra-fast tracking converters and MOS-gate driver circuits in medium and high voltage applications. The key feature of the design is its very low circuit input-to-output parasitic capacitance, which maximizes its...

  18. tkLayout: a Design Tool for Innovative Silicon Tracking Detectors

    CERN Document Server

    Bianchi, Giovanni

    2014-01-01

    A new CMS tracker is scheduled to become operational for the LHC Phase 2 upgrade in the early 2020's. tkLayout is a software package developed to create 3d models for the design of the CMS tracker and to evaluate its fundamental performance figures. The new tracker will have to cope with much higher luminosity conditions, resulting in increased track density, harsher radiation exposure and, especially, much higher data acquisition bandwidth, such that equipping the tracker with triggering capabilities is envisaged. The design of an innovative detector involves deciding on an architecture offering the best trade-off among many figures of merit, such as tracking resolution, power dissipation, bandwidth, cost and so on. Quantitatively evaluating these figures of merit as early as possible in the design phase is of capital importance and it is best done with the aid of software models. tkLayout is a flexible modeling tool: new performance estimates and support for different detector geometries can be quickly ad...

  19. High patient satisfaction in 445 patients who underwent fast-track hip or knee replacement

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    BACKGROUND AND PURPOSE: Patient satisfaction is important in fast-track total hip and knee replacement (THR, TKR). We assessed: (1) how satisfied patients were with the treatment; (2) factors related to overall satisfaction; and (3) whether there was a difference between THR and TKR regarding...... length of stay (LOS) and patient satisfaction. PATIENTS AND METHODS: In this follow-up study, a consecutive series of 445 patients undergoing THR and TKR completed a questionnaire 2 weeks after discharge. LOS and short-term patient satisfaction with the fast-track management were measured. Patient...... satisfaction was measured using a numerical rating scale (NRS; 0-10). RESULTS: For THR, the median satisfaction score was 9-10 and for TKR it was 8.5-10 in all parameters. Older THR patients had higher overall satisfaction. No association was found between overall satisfaction following THR or TKR and sex...

  20. Cognitive dysfunction after fast-track hip and knee replacement

    DEFF Research Database (Denmark)

    Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben

    2014-01-01

    to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). RESULTS: Median LOS was 2 days (interquartile range...... this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). CONCLUSIONS: The incidence of POCD early after total hip and knee replacement seems to be lower after a fast-track approach than rates previously reported...

  1. Electromobility. Are the suppliers equipped for the structural change? State of the art and recommendations for action for the automotive location Stuttgart; Elektromobilitaet. Zulieferer fuer den Strukturwandel geruestet? Status quo und Handlungsempfehlungen fuer den Automobilstandort Metropolregion Stuttgart

    Energy Technology Data Exchange (ETDEWEB)

    Stahlecker, Thomas; Lay, Gunter; Zanker, Christoph [Fraunhofer-Institut fuer System- und Innovationsforschung (ISI), Karlsruhe (Germany)

    2011-04-15

    The contribution under consideration examines the future viability of automotive suppliers in Baden-Wuerttemberg (Federal Republic of Germany) in terms of a technological change. The question has to be examined whether the innovation potential of the automotive supplier is adequate in order to face the potential restructuring demands successfully. The investigations show that the automotive supply industry at the top still is positioned very well. In contrast, medium-sized suppliers rather are poorly equipped regarding the challenges of electromobility. With this in mind three strategic options for companies in the automotive industry as well as for the policy were formulated. A tabular summary provides an overview on the identified bottlenecks of small and medium-sized automotive supplier in the field of electric vehicles.

  2. IAEA Technical Meeting on Innovative Fast Reactor Designs with Enhanced Negative Reactivity Feedback Features. Presentations

    International Nuclear Information System (INIS)

    2012-01-01

    The objective of the TM is to review and discuss the safety characteristics and the performances of the core of innovative fast reactor concepts, as well as to present the ongoing R&D activities in the area of core design and advanced simulation tools and methods for fast reactor core physics analysis. The focus is on fast spectrum cores optimized for actinide utilization and transmutation and, in particular, on core designs with enhanced negative reactivity feedback effects

  3. Clinical evidence of traditional vs fast track recovery methodologies after total arthroplasty for osteoarthritic knee treatment. A retrospective observational study

    Science.gov (United States)

    Castorina, Sergio; Guglielmino, Claudia; Castrogiovanni, Paola; Szychlinska, Marta Anna; Ioppolo, Francesco; Massimino, Paolo; Leonardi, Pietro; Maci, Christian; Iannuzzi, Maurizio; Di Giunta, Angelo; Musumeci, Giuseppe

    2017-01-01

    Summary Background During the last years, programs to enhance postoperative recovery and decrease morbidity after total knee arthroplasty, have been developed across a variety of surgical procedures and referred to as “Fast-Track Surgery”. In this study we aimed to find some answers in the management of osteoarthritic patients subjected to total knee arthroplasty, by using the Fast-Track methodology. To this purpose we evaluated parameters such as early mobilization of patients, better pain management, bleeding, possible complications, reduced hospitalization time, an overall improved recovery and patient satisfaction. Methods 132 patients were selected, of which, 95 treated with “Fast Track” method and 37 treated with traditional method (control group). All the patients were hospitalized and underwent the same rehabilitation program for the first three days after surgery. Results In both groups, the parameters of pain and deformity demonstrated the most rapid improvement, while those of function and movement were normalized as gradual and progressive improvement over the next 2 months. The different functional test used (Barthel, MRC, VAS) showed that the mean values were significantly greater in Fast Track group when compared to the control. Conclusion The results of the study confirm that the application of the Fast Track protocol in orthopaedics after total knee replacement results in rapid post-surgery recovery. Level of evidence IV. Case series, low-quality cohort or case-control studies. PMID:29387645

  4. A prospective cohort study to investigate cost-minimisation, of Traditional open, open fAst track recovery and laParoscopic fASt track multimodal management, for surgical patients with colon carcinomas (TAPAS study).

    NARCIS (Netherlands)

    Reurings, J.C.; Spanjersberg, W.R.; Oostvogel, H.J.M.; Buskens, E.; Maring, J.; Kruijt, F.; Rosman, C.; Duivendijk, P. van; Dejong, C.H.; Laarhoven, C.J.H.M. van

    2010-01-01

    BACKGROUND: The present developments in colon surgery are characterized by two innovations: the introduction of the laparoscopic operation technique and fast recovery programs such as the Enhanced Recovery After Surgery (ERAS) recovery program. The Tapas-study was conceived to determine which of the

  5. Fast neutron dosimetry by means of different solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The comparative study of three different types of fast neutron dosimeters based on solid state nuclear track detectors is presented; the dosimeters studied were: - microscopic soda glass in contact with 232 Th; - polycarbonate Makrofol E; and - cellulose nitrate Kodak LR 115. All detectors were evaluated by visual counting in a microscope. The authors have studied such properties as the background, angular as well as energetical dependences of detectors. The results obtained show that all studied detectors are suitable for fast neutron dosimetry; their application depends however on the concrete experimental conditions (neutron spectrum, fluence etc.). Both advantages and disadvantages of each of them are presented. (Auth.)

  6. tkLayout: a design tool for innovative silicon tracking detectors

    Science.gov (United States)

    Bianchi, G.

    2014-03-01

    A new CMS tracker is scheduled to become operational for the LHC Phase 2 upgrade in the early 2020's. tkLayout is a software package developed to create 3d models for the design of the CMS tracker and to evaluate its fundamental performance figures. The new tracker will have to cope with much higher luminosity conditions, resulting in increased track density, harsher radiation exposure and, especially, much higher data acquisition bandwidth, such that equipping the tracker with triggering capabilities is envisaged. The design of an innovative detector involves deciding on an architecture offering the best trade-off among many figures of merit, such as tracking resolution, power dissipation, bandwidth, cost and so on. Quantitatively evaluating these figures of merit as early as possible in the design phase is of capital importance and it is best done with the aid of software models. tkLayout is a flexible modeling tool: new performance estimates and support for different detector geometries can be quickly added, thanks to its modular structure. Besides, the software executes very quickly (about two minutes), so that many possible architectural variations can be rapidly modeled and compared, to help in the choice of a viable detector layout and then to optimize it. A tracker geometry is generated from simple configuration files, defining the module types, layout and materials. Support structures are automatically added and services routed to provide a realistic tracker description. The tracker geometries thus generated can be exported to the standard CMS simulation framework (CMSSW) for full Monte Carlo studies. tkLayout has proven essential in giving guidance to CMS in studying different detector layouts and exploring the feasibility of innovative solutions for tracking detectors, in terms of design, performance and projected costs. This tool has been one of the keys to making important design decisions for over five years now and has also enabled project engineers

  7. Electrochemical etching amplification of low-let recoil particle tracks in polymers for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Sohrabi, M.; Morgan, K.Z.

    1975-11-01

    An electrochemical etching method for the amplification of fast-neutron-induced recoil particle tracks in polymers was investigated. The technique gave superior results over those obtained by conventional etching methods especially when polycarbonate foils were used for recoil particle track amplification. Electrochemical etching systems capable of multi-foil processing were designed and constructed to demonstrate the feasibility of the techniques for large-scale neutron dosimetry. Electrochemical etching parameters were studied including the nature or type of the polymer foil used, foil thickness and its effect on etching time, the applied voltage and its frequency, the chemical composition, concentration, and temperature of the etchant, distance and angle between the electrodes, and the type of particles such as recoil particles including protons. Recoil particle track density, mean track diameter, and optical density as functions of the mentioned parameters were determined. Each parameter was found to have a distinct effect on the etching results in terms of the measured responses. Several new characteristics of this fast neutron dosimetry method were studied especially for personnel dosimetry using various radiation sources such as nuclear reactors, medical cyclotrons, and isotopic neutron sources. The dose range, neutron energy dependence, directional response, fading characteristics, neutron threshold energy, etc. were investigated

  8. Ressource efficiency and ressource political aspects of the system electromobility. Work package 7 of the research program OPTUM. Optimization of the potentials for environmental relief of electric-powered vehicles; Ressourceneffizienz und ressourcenpolitische Aspekte des Systems Elektromobilitaet. Arbeitspaket 7 des Forschungsvorhabens OPTUM. Optimierung der Umweltentlastungspotenziale von Elektrofahrzeugen

    Energy Technology Data Exchange (ETDEWEB)

    Buchert, Matthias; Jenseit, Wolfgang; Dittrich, Stefanie; Hacker, Florian [Oeko-Institut e.V. - Institut fuer Angewandte Oekologie, Darmstadt (Germany); Schueler-Hainsch, Eckhard; Ruhland, Klaus; Knoefel, Sven [Daimler AG, Stuttgart (Germany); Goldmann, Daniel; Rasenack, Kai [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany); Treffer, Frank [Umicore, Hanau-Wolfgang (Germany)

    2011-10-28

    The development and successful implementation of the electric mobility is a key factor for a sustainable mobility. The Federal Government has passed the National Electromobility Development Plan on 19th August 2009. In the context of resource efficiency and resource-political aspects of the system electromobility the following sub-targets are addressed: (1) Identification of the main raw materials for electric-powered vehicles; (2) Determination of the quantitative demand for these raw materials by means of a scenario technique; (3) Investigation of the environmental impact of the production and processing of raw materials, comparison of the environmental impact with the environmental benefits due to the electromobility; (4) Comprehensive investigation of how the recycling of raw materials is feasible technically and economically; (5) Transparent display of available reserves of these raw materials and assessment of the extend of available resources; (6) Determination of the overall impact of the planned expansion of electromobility on the supply situation and the future price development of raw materials required; (7) Analysis of alternative technologies for single components for the reduction in demand of the required raw materials.

  9. Fast-track, ambulatory ultrasound-guided Tru-Cut liver biopsy is feasible and cost-efficient

    DEFF Research Database (Denmark)

    Huang, Chenxi; Lorentzen, Torben; Skjoldbye, Bjørn

    2015-01-01

    safely discharged from our institution. No fatality or long-term complications were found during this study. CONCLUSION: The fast-track approach reported herein is a feasible option when adequate patient information is given. Besides the obvious, positive effect on patient logistics and departmental...

  10. Fast neutron detection by means of an organic solid state track detector

    International Nuclear Information System (INIS)

    Doerschel, B.; Streubel, G.

    1980-01-01

    Solid state track detectors consisting of cellulose triacetate foils are appropriate for measuring the fast neutron fluence without applying external radiators. Detector sensitivity has been determined as a function of neutron energy by performing irradiations with various neutron sources and monoenergetic neutrons of different energies. A comparison with theoretical results given in the literature for a simple model of track recording has shown sufficient agreement. The measuring errors and the influence of spectral changes in the neutron field on detector response are discussed for the studied method of fluence measurement. By means of these errors the measuring range has been determined for well defined irradiation conditions, taking into account spectral changes in the neutron field. (author)

  11. Nopea toipuminen lihavuusleikkauksen jälkeen : Fast track- toimintamallin mukainen potilasohjausvihko lihavuusleikkauspotilaalle Oulun yliopistollisen sairaalan osastolle yhdeksän

    OpenAIRE

    Niskala, Jenni; Nevala, Elisa

    2013-01-01

    Oulun yliopistollisen sairaalan osastolla yhdeksän oli tarve saada Fast track -toimintamallin mukainen potilasohjausvihko lihavuusleikkauspotilaille. Opinnäytetyön tekijät valitsivat opinnäytetyön aiheen perioperatiivisen suuntautumisvaihtoehdon mukaan. Tämä opinnäytetyö toteutettiin projektityönä. Opinnäytetyön tarkoituksena oli tehdä Fast track- toimintamallin mukainen potilasohjausvihko Oulun Yliopistollisen sairaalan osasto yhdeksän käyttöön. Opinnäytetyön tavoitteena oli edesauttaa ...

  12. Impact of fast-track concept elements in the classical pancreatic head resection (Kausch-Whipple procedure).

    Science.gov (United States)

    Gastinger, Ingo; Meyer, Frank; Lembcke, Thomas; Schmidt, Uwe; Ptok, Henry; Lippert, Hans

    2012-08-01

    The aim of the study was to determine statistically significant factors with an impact on the early postoperative surgical outcome. The influence of applied fast-track components on surgical results and early postoperative outcome in 143 consecutive Kausch-Whipple procedure patients was evaluated in a single-center retrospective analysis of a prospective collection of patient-associated pre-, peri- and postoperative data from 1997-2006. The in-hospital mortality rate was 2.8% (n=4). Fast-track measures were shown to have no effect on the morbidity rate in the multi-variate analysis. Over the study period, a decrease of intraoperative infusion volume from 14.2 mL/kg body weight/h in the first year to 10.7 mL/kg body weight/h in the last year was accompanied by an increase in patients requiring intraoperative catecholamines, up from 17% to 95%. The administration of ropivacain/sufentanil via thoracic peri-dural catheter injection initiated in 2000 and now considered the leading analgesic method, was used in 95% of the cases in 2006. Early extubation rate rose from 16.6% to 57.9%. Fast-track aspects in the perioperative management have become more important in several surgical procedure even in those with a greater invasiveness such as Kausch-Whipple. However, such techniques used in peri-operative management of Kausch-Whipple pancreatic-head resections had no impact on the morbidity rate. In addition, the low in-hospital mortality rate was particularly attributed to surgical competence.

  13. IAEA Technical Meeting on Innovative Fast Reactor Designs with Enhanced Negative Reactivity Feedback Features. Working Material

    International Nuclear Information System (INIS)

    2012-01-01

    The objective of the TM was to review and discuss the safety characteristics and the performances of the core of innovative fast reactor concepts, as well as to present the ongoing R&D activities in the area of core design and advanced simulation tools and methods for fast reactor core physics analysis. The focus was on fast spectrum cores optimized for actinide utilization and transmutation and, in particular, on core designs with enhanced negative reactivity feedback effects

  14. SMEs in Energy: Are they the parallel fast track for electrification of Africa?

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rahman, Mohamed

    2010-09-15

    The African continent is suffering from a chronic energy shortage that hiders its development. The conventional wisdom is to put the Mega projects under focus. However, a parallel fast track for the energy as an SME business may bring faster results to the continent. To that end, this paper presents proposed steps to promote the concept within the continent.

  15. Fast Tracker: A Hardware Real Time Track Finder for the ATLAS Trigger System

    CERN Document Server

    Kimura, N; The ATLAS collaboration

    2014-01-01

    The Fast Tracker (FTK) is an integral part of the trigger upgrade program for the ATLAS detector at the Large Hadron Collider (LHC). As the LHC luminosity approaches its design level of 10^34cm^−2s^−1, the combinatorial problem posed by charged particle tracking becomes increasingly difficult due to the swelling of multiple interactions per bunch crossing (pile-up). The FTK is a highly-parallel hardware system intended to provide high-quality tracks with transverse momentum above 1 GeV/c in real time for online trigger system. The FTK system’s design, based on a mixture of advanced technologies, and expected physics performance will be presented.

  16. "Joined up" Thinking? Unsupported "Fast-Track" Transitions in the Context of Parental Substance Use

    Science.gov (United States)

    Wilson, Sarah; Cunningham-Burley, Sarah; Bancroft, Angus; Backett-Milburn, Kathryn

    2008-01-01

    Recent policy responses to the risks entailed in "fast-track" school-work transitions have targeted careleavers and young people identified as "not in education, employment or training" (NEET). However, this approach has been criticised as diverting attention away from the fragile circumstances of others who may receive little…

  17. Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Fabian; Rief, Matthias; Zimmermann, Elke; Greupner, Johannes; Richter, Felicitas; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany)

    2014-06-15

    Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. (orig.)

  18. Fast-track remediation case study: Southern California refined fuel distributor

    International Nuclear Information System (INIS)

    Bubier, T.W.; Felix, P.R.

    1993-01-01

    Successful environmental remediation projects have three requirements in common: (1) an adequate data base that defines the extent and severity of the problem; (2) a detailed understanding of the actual performance of the remediation technologies being considered; and (3) good communication with the regulatory agencies to assure them that the health and safety of the community and workers will not be jeopardized. In a fast-track remediation project, these requirements are key issues in the critical path. The case study involves soil and groundwater remediation of a 16-acre bulk fuel storage and distribution facility. The facility was in operation for approximately 75 years and contained 20 large aboveground tanks with a total capacity in excess of 20 million gallons. Activities at the facility included receipt, storage, and distribution of refined fuel products, such as kerosene, gasoline, diesel, and bunker fuel. A harbor-widening project was undertaken to increase the level of safety for larger ships when passing through the port. Because of the critical need for harbor-widening, the environmental cleanup needed to be completed as quickly as possible. The following steps were taken during the fast-track remediation case study to meet the above-listed requirements: (1) New Data Quality Objectives (DQOs) were identified for the project; (2) Potentially applicable remedial technologies were evaluated and tested; and (3) An agency task force was developed to enhance communication with the regulatory agencies. This paper discusses these steps and presents examples of how each step was implemented during the remediation case study

  19. Fast parallel tracking algorithm for the muon detector of the CBM experiment at FAIR

    International Nuclear Information System (INIS)

    Lebedev, A.; Hoehne, C.; Kisel', I.; Ososkov, G.

    2010-01-01

    Particle trajectory recognition is an important and challenging task in the Compressed Baryonic Matter (CBM) experiment at the future FAIR accelerator at Darmstadt. The tracking algorithms have to process terabytes of input data produced in particle collisions. Therefore, the speed of the tracking software is extremely important for data analysis. In this contribution, a fast parallel track reconstruction algorithm, which uses available features of modern processors is presented. These features comprise a SIMD instruction set (SSE) and multithreading. The first allows one to pack several data items into one register and to operate on all of them in parallel thus achieving more operations per cycle. The second feature enables the routines to exploit all available CPU cores and hardware threads. This parallel version of the tracking algorithm has been compared to the initial serial scalar version which uses a similar approach for tracking. A speed-upfactor of 487 was achieved (from 730 to 1.5 ms/event) for a computer with 2 x Intel Core 17 processors at 2.66 GHz

  20. Hardware-based Tracking at Trigger Level for ATLAS the Fast TracKer (FTK) Project

    CERN Document Server

    INSPIRE-00245767

    2015-01-01

    Physics collisions at 13 TeV are expected at the LHC with an average of 40-50 proton-proton collisions per bunch crossing under nominal conditions. Tracking at trigger level is an essential tool to control the rate in high-pileup conditions while maintaining a good efficiency for relevant physics processes. The Fast TracKer is an integral part of the trigger upgrade for the ATLAS detector. For every event passing the Level-1 trigger (at a maximum rate of 100 kHz) the FTK receives data from all the channels of the silicon detectors, providing tracking information to the High Level Trigger in order to ensure a selection robust against pile-up. The FTK performs a hardware-based track reconstruction, using associative memory that is based on the use of a custom chip, designed to perform pattern matching at very high speed. It finds track candidates at low resolution (roads) that seed a full-resolution track fitting done by FPGAs. An overview of the FTK system with focus on the pattern matching procedure will be p...

  1. A Fast Track towards the `Higgs' Spin and Parity

    CERN Document Server

    Ellis, John; Sanz, Veronica; You, Tevong

    2012-01-01

    The LHC experiments ATLAS and CMS have discovered a new boson that resembles the long-sought Higgs boson: it cannot have spin one, and has couplings to other particles that increase with their masses, but the spin and parity remain to be determined. We show here that the `Higgs' + gauge boson invariant-mass distribution in `Higgs'-strahlung events at the Tevatron or the LHC would be very different under the J^P = 0+, 0- and 2+ hypotheses, and could provide a fast-track indicator of the `Higgs' spin and parity. Our analysis is based on simulations of the experimental event selections and cuts using PYTHIA and Delphes, and incorporates statistical samples of `toy' experiments.

  2. A midsize tokamak as a fast track to burning plasmas

    Directory of Open Access Journals (Sweden)

    E. Mazzucato

    2011-03-01

    Full Text Available This paper describes the conceptual design of a midsize tokamak as a fast track to the investigation of burning plasmas. It is shown that it could reach large values of energy gain (≥ 10 with only a modest improvement in confinement over the scaling that was used for designing the International Thermonuclear Experimental Reactor (ITER. This can be achieved by operating in a low plasma recycling regime that experiments indicate can lead to improved plasma confinement. The possibility of reaching the necessary conditions of low recycling using a different magnetic divertor from those currently employed in present experiments is discussed.

  3. A Comparative Study of Analog Voltage-mode Control Methods for Ultra-Fast Tracking Power Supplies

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper presents a theoretical and experimental comparison of the standard PWM/PID voltage-mode control method for single-phase buck converters with two highperformance self-oscillating (a.k.a. sliding mode) control methods. The application considered is ultra-fast tracking power supplies...... (UFTPSs) for RF power amplifiers, where the switching converter needs to track a varying reference voltage precisely and quickly while maintaining low output impedance. The small-signal analyses performed on the different controllers show that the hysteretic-type controller can achieve the highest loop...

  4. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Thorborg, Kristian; Husted, Henrik

    2013-01-01

    By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.......By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits....

  5. Opportune acquisition and tracking time for the fast-moving targets in a ground-based telescope

    Science.gov (United States)

    Chen, Juan; Wang, Jianli; Chen, Tao

    2004-10-01

    Acquisition is defined as identification for a fixed target in the related field of sight (FOS), while tracking means the sway of the telescope's axis of sight (AOS). The automatic acquisition and tracking is a process in which the operating way of the telescope should be switched from guiding to automatic tracking. There are some kinds of method to improve the acquisition and tracking ability for fast moving targets: to extend the acquisition and tracking FOS with memory and storage information of the sensor system; the multimode control to improve the dynamic property of the servo system; to choose an opportune time for acquisition and tracking; to select the control regulator parameter in every working states. If the processor of the CCD sensor can temporarily remember and save the information of the target before it moves out of the FOS, correspondingly, the FOS may be extended. The data forecast technology is used to store the target information. The automatic interception experiments are carried out to verify the control strategy.

  6. Improving the ATLAS physics potential with the Fast Track Trigger System

    CERN Document Server

    Cavaliere, Viviana; The ATLAS collaboration

    2015-01-01

    The ATLAS Fast TracKer (FTK) is a custom electronics system that will operate at the full Level-1 accept rate, 100 kHz, to provide high quality tracks as input to the High-Level Trigger. The event reconstruction is performed in hardware, thanks to the massive parallelism of associative memories (AM) and FPGAs. We present the advantages for the physics goals of the ATLAS experiment and the recent results on the design, technological advancements and testing of some of the core components used in the processor.

  7. Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO

    Science.gov (United States)

    Wintemitz, Luke; Boegner, Greg; Sirotzky, Steve

    2004-01-01

    A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.

  8. A reengineering success story: process improvement in emergency department x-ray cycle time, leading to breakthrough performance in the ED ambulatory care (Fast Track) process.

    Science.gov (United States)

    Espinosa, J A; Treiber, P M; Kosnik, L

    1997-01-01

    This article describes the journey of a multidisciplinary reengineering team, which worked to reduce a critical, high-leverage process in an emergency department setting. The process selected was emergency department radiology services. This process was selected on a rational basis. The team knew tht 60 percent of our emergency department patients were truly ambulatory, and that most could be seen in a "fast track" process as part of our emergency department's core mission. However, we knew from customer satisfaction data, that patients would like to be "in and out" of emergency department Fast Track in less than an hour. Over half of our Fast Track patients require x-rays. For most, this was their sole reason for seeking emergency care. Our state, at the start of the project, included an average x-ray cycle time of over 60 minutes. The associated Fast-Track cycle time was over 90 minutes median. It was clear to the emergency department leadership, as well as to members of the Fast-Track management team, that a cycle time of 30 minutes or less for x-ray service was needed as a necessary condition to an hour or less Fast Track cycle time. It was also felt that a more rapid x-ray cycle time would allow for more rapid turn over of ED rooms, leading to a virtual greater capacity to the ED. It was hoped that this would lead to a reduction in the time from arrival to treatment by the emergency physician for all patients.

  9. International collaborative project to compare and track the nutritional composition of fast foods

    Directory of Open Access Journals (Sweden)

    2012-07-01

    Full Text Available Abstract Background Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Methods/design Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. Discussion This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  10. International collaborative project to compare and track the nutritional composition of fast foods.

    Science.gov (United States)

    2012-07-27

    Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  11. Philosophy for Welders: Colleges Offer Innovative Humanities Curricula for Liberal Arts and Career Track Students Alike

    Science.gov (United States)

    Finkel, Ed

    2016-01-01

    Does America needs more welders and fewer philosophers? Community college humanities professors and administrators say it benefits all students, whether liberal arts or career track, to take courses in philosophy, history, political science, language arts, and other liberal arts subjects. And they're developing innovative humanities curricula to…

  12. Faster recovery of gastrointestinal transit after laparoscopy and fast-track care in patients undergoing colonic surgery

    NARCIS (Netherlands)

    van Bree, Sjoerd; Vlug, Malaika; Bemelman, Willem; Hollmann, Markus; Ubbink, Dirk; Zwinderman, Koos; de Jonge, Wouter; Snoek, Susanne; Bolhuis, Karen; van der Zanden, Esmerij; The, Frans; Bennink, Roel; Boeckxstaens, Guy

    2011-01-01

    Postoperative ileus is characterized by delayed gastrointestinal (GI) transit and is a major determinant of recovery after colorectal surgery. Both laparoscopic surgery and fast-track multimodal perioperative care have been reported to improve clinical recovery. However, objective measures

  13. Does BMI influence hospital stay and morbidity after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C; Gromov, Kirill

    2016-01-01

    Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality in such pat......Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality...... in such patients who were operated with the fast-track methodology and compared the levels with those in patients with normal BMI. Patients and methods - This was a prospective observational study involving 13,730 procedures (7,194 THA and 6,536 TKA operations) performed in a standardized fast-track setting....... Complete 90-day follow-up was achieved using national registries and review of medical records. Patients were grouped according to BMI as being underweight, of normal weight, overweight, obese, very obese, and morbidly obese. Results - Median length of stay (LOS) was 2 (IQR: 2-3) days in all BMI groups. 30...

  14. A process model for design team communication within fast-track building projects using project websites

    NARCIS (Netherlands)

    Otter, den A.F.H.J.; Reymen, I.M.M.J.

    2008-01-01

    The factor time within building projects is on high pressure because of the increasing need for faster delivery of buildings. Within fast track, complex building projects the design process is an important key. Through case analyses offart-hack design processes it became obvious that process and

  15. Time course and reasons for 90-day mortality in fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, H

    2017-01-01

    : Prospective observational study in 13,775 consecutive THA/TKAs with similar fast-track protocols and a median length of stay of 2 days. Complete 90-days follow-up through national registries, followed by review of medical records and death certificates. Relation between mortality and surgically induced organ...

  16. Development of Ultra-Fast Silicon Detectors for 4D tracking

    Science.gov (United States)

    Staiano, A.; Arcidiacono, R.; Boscardin, M.; Dalla Betta, G. F.; Cartiglia, N.; Cenna, F.; Ferrero, M.; Ficorella, F.; Mandurrino, M.; Obertino, M.; Pancheri, L.; Paternoster, G.; Sola, V.

    2017-12-01

    In this contribution we review the progress towards the development of a novel type of silicon detectors suited for tracking with a picosecond timing resolution, the so called Ultra-Fast Silicon Detectors. The goal is to create a new family of particle detectors merging excellent position and timing resolution with GHz counting capabilities, very low material budget, radiation resistance, fine granularity, low power, insensitivity to magnetic field, and affordability. We aim to achieve concurrent precisions of ~ 10 ps and ~ 10 μm with a 50 μm thick sensor. Ultra-Fast Silicon Detectors are based on the concept of Low-Gain Avalanche Detectors, which are silicon detectors with an internal multiplication mechanism so that they generate a signal which is factor ~10 larger than standard silicon detectors. The basic design of UFSD consists of a thin silicon sensor with moderate internal gain and pixelated electrodes coupled to full custom VLSI chip. An overview of test beam data on time resolution and the impact on this measurement of radiation doses at the level of those expected at HL-LHC is presented. First I-V and C-V measurements on a new FBK sensor production of UFSD, 50 μm thick, with B and Ga, activated at two diffusion temperatures, with and without C co-implantation (in Low and High concentrations), and with different effective doping concentrations in the Gain layer, are shown. Perspectives on current use of UFSD in HEP experiments (UFSD detectors have been installed in the CMS-TOTEM Precision Protons Spectrometer for the forward physics tracking, and are currently taking data) and proposed applications for a MIP timing layer in the HL-LHC upgrade are briefly discussed.

  17. Automatic detection of recoil-proton tracks and background rejection criteria in liquid scintillator-micro-capillary-array fast neutron spectrometer

    Science.gov (United States)

    Mor, Ilan; Vartsky, David; Dangendorf, Volker; Tittelmeier, Kai.; Weierganz, Mathias; Goldberg, Mark Benjamin; Bar, Doron; Brandis, Michal

    2018-06-01

    We describe an analysis procedure for automatic unambiguous detection of fast-neutron-induced recoil proton tracks in a micro-capillary array filled with organic liquid scintillator. The detector is viewed by an intensified CCD camera. This imaging neutron detector possesses the capability to perform high position-resolution (few tens of μm), energy-dispersive transmission-imaging using ns-pulsed beams. However, when operated with CW or DC beams, it also features medium-quality spectroscopic capabilities for incident neutrons in the energy range 2-20 MeV. In addition to the recoil proton events which display a continuous extended track structure, the raw images exhibit complex ion-tracks from nuclear interactions of fast-neutrons in the scintillator, capillaries quartz-matrix and CCD. Moreover, as expected, one also observes a multitude of isolated scintillation spots of varying intensity (henceforth denoted "blobs") that originate from several different sources, such as: fragmented proton tracks, gamma-rays, heavy-ion reactions as well as events and noise that occur in the image-intensifier and CCD. In order to identify the continuous-track recoil proton events and distinguish them from all these background events, a rapid, computerized and automatic track-recognition-procedure was developed. Based on an appropriately weighted analysis of track parameters such as: length, width, area and overall light intensity, the method is capable of distinguishing a single continuous-track recoil proton from typically surrounding several thousands of background events that are found in each CCD frame.

  18. Spouses’ involvement in older patients’ fast-track programmes during total hip replacement using case management intervention. A study protocol of the SICAM-trial

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher; Kristensson, Jimmie

    2015-01-01

    Aim To present the protocol of a two-group quasi-experimental study of spouses’ involvement through case management (The SICAM-trial) in older patients’ fast-track programmes during total hip replacement. Background Patients in fast-track programmes are required to take an active part in their tr......Aim To present the protocol of a two-group quasi-experimental study of spouses’ involvement through case management (The SICAM-trial) in older patients’ fast-track programmes during total hip replacement. Background Patients in fast-track programmes are required to take an active part...... in their treatment and rehabilitation. Spouses of older patients can often provide valued practical and emotional support, reducing stress, pain and length of stay – yet they are seldom invited to participate in a supporting role. Design A two-group quasi-experimental design with pre-test and repeated post...... and subsequently include the intervention group to avoid contamination of the control group. A case manager will be recruited to perform the case management intervention. Data will be collected from both groups at baseline, 2 weeks and 3 months after surgery. Outcome measures for patients include: functional...

  19. New Medical-School Programs Put Students on a Fast Track to the White Coat

    Science.gov (United States)

    Mangan, Katherine

    2009-01-01

    California's lieutenant governor has proposed a fast-track medical school that would shave three years off the training needed to become a physician. It is not the first time such an idea has been offered. The proposal, for a hoped-for medical school at the University of California at Merced, struck some medical educators as both unrealistic and…

  20. Being Disruptive: How Open Growth is Delivering Effective Social Change at a Fast Pace

    Directory of Open Access Journals (Sweden)

    Delyse Sylvester

    2012-07-01

    Full Text Available Both innovators and funders need tools that map the entire constellation of solutions in a sector. Innovators, often labeled and isolated as system disruptors, need to be linked with their global peers offering and seeking each others proven strategies to accelerate positive change. The impact investing space needs a simple, open, and transparent way to find, convene, support, and track the progress of innovators. This article describes how the Ashoka Changemakers.com online community creates a space for: investors to find and support multiple innovations; social innovators to find each other, work together, and source funds; and disruptive innovations to grow over time where disruptive change is needed, fast. Crowd-sourcing, transparency, and open growth are keys to accelerating large-scale change and creating a world of changemakers.

  1. Implementation and Performance of FPGA based track fitting for the Atlas Fast TracKer

    CERN Document Server

    Zou, Rui; The ATLAS collaboration

    2018-01-01

    The Fast TracKer (FTK) within the ATLAS trigger system provides global track reconstruction for all events passing the ATLAS Level 1 trigger by dividing the detector into parallel processing pipelines that implement pattern matching in custom integrated circuits and data routing, reduction, and parameter extraction in FPGAs. In this presentation we will describe the implementation of a critical component of the system which does partial track fitting using a method based on a principal component analysis at a rate of greater than 1 fit per 10 ps, system-wide, to reduce the output of the pattern matching. Firmware design, timing performance and preliminary results will be discussed.

  2. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    Science.gov (United States)

    Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith

    2013-05-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.

  3. Methodology for assessing electric vehicle charging infrastructure business models

    International Nuclear Information System (INIS)

    Madina, Carlos; Zamora, Inmaculada; Zabala, Eduardo

    2016-01-01

    The analysis of economic implications of innovative business models in networked environments, as electro-mobility is, requires a global approach to ensure that all the involved actors obtain a benefit. Although electric vehicles (EVs) provide benefits for the society as a whole, there are a number of hurdles for their widespread adoption, mainly the high investment cost for the EV and for the infrastructure. Therefore, a sound business model must be built up for charging service operators, which allows them to recover their costs while, at the same time, offer EV users a charging price which makes electro-mobility comparable to internal combustion engine vehicles. For that purpose, three scenarios are defined, which present different EV charging alternatives, in terms of charging power and charging station ownership and accessibility. A case study is presented for each scenario and the required charging station usage to have a profitable business model is calculated. We demonstrate that private home charging is likely to be the preferred option for EV users who can charge at home, as it offers a lower total cost of ownership under certain conditions, even today. On the contrary, finding a profitable business case for fast charging requires more intensive infrastructure usage. - Highlights: • Ecosystem is a network of actors who collaborate to create a positive business case. • Electro-mobility (electricity-powered road vehicles and ICT) is a complex ecosystem. • Methodological analysis to ensure that all actors benefit from electro-mobility. • Economic analysis of charging infrastructure deployment linked to its usage. • Comparison of EV ownership cost vs. ICE for vehicle users.

  4. Fast neutron detection using solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Vilela, E.C.

    1990-01-01

    CR-39 and Makrofol-E solid state nuclear track detectors were studied aiming their application to fast neutron detection. Optimum etching conditions of those two kinds of materials were determined the followings - the Makrofol-E detector is electrochemically etched in a PEW solution (15% KOH, 40% ethilic alcohol and 45% water) for 2 h., with an applied electric field strength of 30 kV/cm (r/m/s/) and frequency of 2 kHz, at room temperature; - the CR-39 detector is chemically pre-etched during 1 h in a 20% (w/v) NaOH solution at 70 sup(0)C, followed by 13 h electrochemical etch using the same solution at room temperature and an electric field strength of 30 kV/cm (r.m.s.) and frequency of 2 kHz.(E.G.)

  5. Preoperative prediction of potentially preventable morbidity after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Petersen, Morten Aa; Kehlet, Henrik

    2016-01-01

    . DESIGN: Prospective observational study. SETTING: Elective primary unilateral total hip and knee arthroplasty with prospectively collected preoperative patient characteristics; similar standardised fast-track protocols; evaluation of complications through discharge and medical records; and complete 90...... days follow-up through nationwide databases. PARTICIPANTS: 8373 consecutive unselected total hip arthroplasty (THA) and knee arthroplasty from January 2010 to November 2012. RESULTS: There were 557 procedures (6.4%) followed by potentially preventable complications resulting in hospitalisation >4 days...

  6. Innovative molecular-based fluorescent nanoparticles for multicolor single particle tracking in cells

    International Nuclear Information System (INIS)

    Daniel, Jonathan; Blanchard-Desce, Mireille; Godin, Antoine G; Palayret, Matthieu; Lounis, Brahim; Cognet, Laurent

    2016-01-01

    Based on an original molecular-based design, we present bright and photostable fluorescent organic nanoparticles (FONs) showing excellent colloidal stability in various aqueous environments. Complementary near-infrared emitting and green emitting FONs were prepared using a simple, fast and robust protocol. Both types of FONs could be simultaneously imaged at the single-particle level in solution as well as in biological environments using a monochromatic excitation and a dual-color fluorescence microscope. No evidence of acute cytotoxicity was found upon incubation of live cells with mixed solutions of FONs, and both types of nanoparticles were found internalized in the cells where their motion could be simultaneously tracked at video-rate up to minutes. These fluorescent organic nanoparticles open a novel non-toxic alternative to existing nanoparticles for imaging biological structures, compatible with live-cell experiments and specially fitted for multicolor single particle tracking. (paper)

  7. A Fast Track approach to deal with the temporal dimension of crop water footprint

    Science.gov (United States)

    Tuninetti, Marta; Tamea, Stefania; Laio, Francesco; Ridolfi, Luca

    2017-07-01

    Population growth, socio-economic development and climate changes are placing increasing pressure on water resources. Crop water footprint is a key indicator in the quantification of such pressure. It is determined by crop evapotranspiration and crop yield, which can be highly variable in space and time. While the spatial variability of crop water footprint has been the objective of several investigations, the temporal variability remains poorly studied. In particular, some studies approached this issue by associating the time variability of crop water footprint only to yield changes, while considering evapotranspiration patterns as marginal. Validation of this Fast Track approach has yet to be provided. In this Letter we demonstrate its feasibility through a comprehensive validation, an assessment of its uncertainty, and an example of application. Our results show that the water footprint changes are mainly driven by yield trends, while evapotranspiration plays a minor role. The error due to considering constant evapotranspiration is three times smaller than the uncertainty of the model used to compute the crop water footprint. These results confirm the suitability of the Fast Track approach and enable a simple, yet appropriate, evaluation of time-varying crop water footprint.

  8. The use of a break-even analysis: financial analysis of a fast-track program.

    Science.gov (United States)

    Saywell, R M; Cordell, W H; Nyhuis, A W; Giles, B K; Culler, S D; Woods, J R; Chu, D K; McKinzie, J P; Rodman, G H

    1995-08-01

    To calculate the financial break-even point and illustrate how changes in third-party reimbursement and eligibility could affect a program's fiscal standing. Demographic, clinical, and financial data were collected retrospectively for 446 patients treated in a fast-track program during June 1993. The fast-track program is located within the confines of the emergency medicine and trauma center at a 1,050-bed tertiary care Midwestern teaching hospital and provides urgent treatment to minimally ill patients. A financial break-even analysis was performed to determine the point where the program generated enough revenue to cover its total variable and fixed costs, both direct and indirect. Given the relatively low average collection rate (62%) and high percentage of uninsured patients (31%), the analysis showed that the program's revenues covered its direct costs but not all of the indirect costs. Examining collection rates or payer class mix without examining both costs and revenues may lead to an erroneous conclusion about a program's fiscal viability. Sensitivity analysis also shows that relatively small changes in third-party coverage or eligibility (income) requirements can have a large impact on the program's financial solvency and break-even volumes.

  9. Improving the quality of pretreatment staging in patients with esophageal carcinoma - a fast track study

    Energy Technology Data Exchange (ETDEWEB)

    Didden, Paul; Spaander, Manon C. W.; Kuipers, Ernst J.; Bruno, Marco J. (Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam (Netherlands)), E-mail: v.spaander@erasmusmc.nl; Wijnhoven, Bas P. L. (Department of Surgery, Erasmus University Medical Center, Rotterdam (Netherlands))

    2012-03-15

    Background: Current guidelines for esophageal cancer recommend series of diagnostic investigations to determine pretreatment TNM stage. When investigations are done sequentially, diagnostic work-up time may be prolonged considerably. Aim of the study was to determine the feasibility and efficacy of a fast track staging strategy within five days after the first consultation. Material and methods: Between 2007 and 2010 all patients presenting with esophageal cancer at the Department of Gastroenterology in a tertiary referral center were prospectively analyzed. At Day 1 all patients underwent computed tomography (CT), endoscopic ultrasound (EUS) and ultrasonography of the neck (United States). Results and treatment implications were discussed within a multidisciplinary meeting. This fast track strategy was considered completed successfully if pre-treatment TNM classification was achieved and therapy was proposed to the patient at the outpatient clinic at Day five. In those cases where staging period time was prolonged, the number and type of additional tests were documented including the ensuing time delay. Results: In 111 patients CT, EUS and US were performed in 100%, 88.3% and 97.3% respectively. A final TNM stage and treatment proposal was reached at Day 5 in 60% of the patients. Additional tests were diverse and mainly used to prove local irresectability or presence of distant metastasis. Multivariate analysis identified presence of lymphadenopathy (HR 0.25 p 0.03) and metastasis (HR 0.27 p = 0.03) as significant predictors of not completing the staging period within five days. In 18% of patients overuse of at least one test occurred, most commonly because CT already revealed distant metastasis. Conclusion: Employment of a fast track five day staging strategy in patients with esophageal carcinoma is feasible. Definite TNM stage and treatment proposal can be achieved in 60% of cases, but comes at the expense of test overuse in about one fifth of patients

  10. Think big, start small, move fast a blueprint for transformation from the Mayo Clinic Center for Innovation

    CERN Document Server

    LaRusso, Nicholas; Farrugia, Gianrico

    2015-01-01

    The Only Innovation Guide You Will Ever Need--from the Award-Winning Minds at Mayo Clinic. A lot of businesspeople talk about innovation, but few companies have achieved the level of truly transformative innovation as brilliantly--or as famously--as the legendary Mayo Clinic. Introducing Think Big, Start Small, Move Fast, the first innovation guide based on the proven, decade-long program that’s made Mayo Clinic one of the most respected and successful organizations in the world. This essential must-have guide shows you how to: Inspire and ignite trailblazing innovation in your workplace Design a new business model that’s creative, collaborative, and sustainable Apply the traditional scientific method to the latest innovations in "design thinking" Build a customized toolkit of the best practices, project portfolios, and strategies Increase your innovation capacity--and watch how quickly you succeed These field-tested techniques grew out of the health care industry but are designed ...

  11. Hardware realization of a fast neural network algorithm for real-time tracking in HEP experiments

    International Nuclear Information System (INIS)

    Leimgruber, F.R.; Pavlopoulos, P.; Steinacher, M.; Tauscher, L.; Vlachos, S.; Wendler, H.

    1995-01-01

    A fast pattern recognition system for HEP experiments, based on artificial neural network algorithms (ANN), has been realized with standard electronics. The multiplicity and location of tracks in an event are determined in less than 75 ns. Hardware modules of this first level trigger were extensively tested for performance and reliability with data from the CPLEAR experiment. (orig.)

  12. Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    Science.gov (United States)

    Miranda, Alan; Staelens, Steven; Stroobants, Sigrid; Verhaeghe, Jeroen

    2017-07-01

    To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET point sources (3-4) attached to the rat's head are tracked in image space using 15-32-ms time frames. Our point source tracking (PST) method was validated using a manually moved microDerenzo phantom that was simultaneously tracked with an optical tracker (OT) for comparison. The PST method was further validated in three awake [ 18 F]FDG rat brain scans. Compared with the OT, the PST-based correction at the same frame rate (31.2 Hz) reduced the reconstructed FWHM by 0.39-0.66 mm for the different tested rod sizes of the microDerenzo phantom. The FWHM could be further reduced by another 0.07-0.13 mm when increasing the PST frame rate (66.7 Hz). Regional brain [ 18 F]FDG uptake in the motion corrected scan was strongly correlated ( ) with that of the anesthetized reference scan for all three cases ( ). The proposed PST method allowed excellent and reproducible motion correction in awake in vivo experiments. In addition, there is no need of specialized tracking equipment or additional calibrations to be performed, the point sources are practically imperceptible to the rat, and PST is ideally suitable for small bore scanners, where optical tracking might be challenging.

  13. The Effects of the Fast Track Preventive Intervention on the Development of Conduct Disorder across Childhood

    Science.gov (United States)

    Child Development, 2011

    2011-01-01

    The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social…

  14. Relatives in older patients' fast-track treatment programme during total hip or knee replacement. A grounded theory study

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher

    and considerate support in concern for the patients; Substituting mode, with practical and cognitive support; and Adapting mode, by trying to fit in with the patients’ and health professionals’ requirements. Study II: 16 patients aged 70 to 94 were included and data was collected through 15 non......The aim of this Ph.D.-dissertation was to generate grounded theories of relatives, patients, and health professionals’ pattern of behaviour, respectively, in relation to the relatives of older patients’ fast-track treatment programmes during total hip or knee replacement. The dissertation includes...... to the older patients’ self-determination of being autonomous and how they adapt and are perceived in the health professionals’ environment. This may be useful to the health professionals in orthopaedic fast-track treatment programmes and their future collaboration with older patients and their relatives....

  15. Role of preoperative anemia for risk of transfusion and postoperative morbidity in fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jans, Øivind; Jørgensen, Christoffer; Kehlet, Henrik

    2014-01-01

    BACKGROUND: Preoperative anemia has been associated with increased risk of allogeneic blood transfusion and postoperative morbidity and mortality. The prevalence of preoperative anemia and its association with postoperative outcomes has not previously been reported in relation to fast......-track elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). We aimed to evaluate the prevalence of preoperative anemia in elective fast-track THA and TKA and its association with risk of perioperative transfusion, prolonged length of hospital stay (LOS), and postoperative readmission. STUDY...... national databases and patient charts. Adjusted risk estimates for transfusion, prolonged LOS, and all-cause readmission according to preoperative anemia status were obtained by multivariate logistic regression. RESULTS: A total of 5.165 THA or TKA procedures were included with a mean patient age of 67...

  16. Nursing in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    must still focus on the individual patient. Nurses need to have enough education to manage the complex tasks and increased responsibility. To prevent undesirable outcomes in the future, there is a need to pay attention to the nursing quality in balance with the nursing budget. It may, therefore......AIM: To describe the increased activity in total hip arthroplasty (THA) and total knee arthroplasty (TKA) from 2002 to 2012 in a single orthopaedic department, the organisation of fast-track and its consequences for nursing care. METHODS: Retrospective, descriptive design. Data collection; from...... gained tasks from surgeons and physiotherapists and thus gained more responsibility, for example, for pain management and mobilisation. Staffing levels in the ward in 2002 and 2012 were almost unchanged; 16.0 and 15.8 respectively. Nurses were undertaking more complicated tasks. CONCLUSION: Nursing care...

  17. Sleep disturbances after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, L; Jennum, P; Kehlet, H

    2012-01-01

    BACKGROUND: /st>Major surgery is followed by pronounced sleep disturbances after traditional perioperative care potentially leading to prolonged recovery. The aim was to evaluate the rapid eye movement (REM) sleep duration and sleep architecture before and after fast-track hip and knee replacement......, and on the fourth postoperative night at home. Sleep staging was performed according to the American Academy of Sleep Medicine manual. Opioid use, pain, and inflammatory response (C-reactive protein) were also evaluated. RESULTS: /st>The mean LOS was 1.5 (1-2) days. The mean REM sleep time decreased from a mean...... on the fourth postoperative night. There was no association between opioid use, pain scores, and inflammatory response with a disturbed sleep pattern. CONCLUSIONS: /st>Despite ultra-short LOS and provision of spinal anaesthesia with multimodal opioid-sparing analgesia, REM sleep was almost eliminated...

  18. First results of the silicon telescope using an 'artificial retina' for fast track finding

    Energy Technology Data Exchange (ETDEWEB)

    Neri, N. [Istituto Nazionale di Fisica Nucleare - INFN, Sezione di Milano, Milano (Italy); Abba, A.; Caponio, F.; Geraci, A.; Grizzuti, M.; Lusardi, N. [INFN Milano and Politecnico di Milano, Milano (Italy); Citterio, M.; Coelli, S.; Fu, J.; Monti, M.; Petruzzo, M. [INFN Milano, Milano (Italy); Bedeschi, F.; Ninci, D.; Piucci, A.; Spinella, F.; Walsh, J. [INFN Pisa, Pisa (Italy); Cenci, R.; Marino, P.; Morello, M. J.; Stracka, S. [INFN Pisa and Scuola Normale Superiore di Pisa, Pisa (Italy); Punzi, G. [INFN Pisa and Universita di Pisa, Pisa (Italy); Tonelli, D. [CERN, Geneva (Switzerland); Ristori, L. [INFN Pisa, Pisa (Italy); Fermilab, Batavia, Illinois (United States)

    2015-07-01

    We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecture is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)

  19. Tracking U.S. biofuel innovation through patents

    International Nuclear Information System (INIS)

    Kessler, Jeff; Sperling, Daniel

    2016-01-01

    We use biofuel patents as a proxy for biofuel innovation. Through use of natural language processing and machine-learning algorithms, we expand patent classification capabilities to better explain the history of biofuels innovation. Results indicate that after the initial establishment of the U.S. biofuel industry, there were two surges in biofuel innovation: 1995–2000, characterized by heavy patenting by 1st generation (food-based) biofuel firms; and 2005–2010, characterized by a second surge of innovation by those same large firms, complemented by a large number of biotechnology firms producing a relatively small number of 2nd generation biofuel patents. Our analysis corroborates the widespread understanding that the first surge in biofuel innovation was linked to innovations in agriculture, and that the second surge of biofuel innovation was driven by demand-pull policies mandating and incentivizing biofuels. But the slow emergence of a 2nd generation cellulose-based biofuels industry, far slower than called for by policy, suggests that technology-push policies more focused on R&D and investment may be needed to accelerate the commercialization of 2nd generation biofuels. - Highlights: • Patenting activity closely corresponds to sociotechnical shifts in biofuel innovation. • The Renewable Fuel Standard likely contributed to the rise in biofuel patenting activity after 2005. • 2nd generation biofuel technology innovation appears lacking compared to 1st generation technologies.

  20. A "package solution" fast track program can reduce the diagnostic waiting time in head and neck cancer

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Johansen, Jørgen; Gano, Lars

    2014-01-01

    and Neck Surgery during three comparable time intervals 2006-2007, 2007-2008, and 2011-2012 (groups 1-3) were investigated. We recorded the time from patient referral, to first consultation and final diagnosis. The first interval was before initiation of the "package solution", the second just after......In 2007, a fast track program for patients with suspicion of head and neck cancer (HNC) was introduced in Denmark to reduce unnecessary waiting time. The program was based on so called "package solutions" including pre-booked slots for outpatient evaluation, imaging, and diagnostic surgical...... procedures. The purpose of this study is to present a model for fast track handling of patients suspicious of cancer in the head and neck region and to evaluate the effect of implementation on the diagnostic work up time. Patients with suspicion of HNC referred to the same university department of ENT Head...

  1. Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Kehlet, Henrik

    2012-01-01

    Bandholm T, Kehlet H. Physiotherapy exercise after fast-track total hip and knee arthroplasty: time for reconsideration? Major surgery, including total hip arthroplasty (THA) and total knee arthroplasty (TKA), is followed by a convalescence period, during which the loss of muscle strength......-track methodology or enhanced recovery programs. It is the nature of this methodology to systematically and scientifically optimize all perioperative care components, with the overall goal of enhancing recovery. This is also the case for the care component "physiotherapy exercise" after THA and TKA. The 2 latest...... meta-analyses on the effectiveness of physiotherapy exercise after THA and TKA generally conclude that physiotherapy exercise after THA and TKA either does not work or is not very effective. The reason for this may be that the "pill" of physiotherapy exercise typically offered after THA and TKA does...

  2. Fast Tracker (FTK): A Hardware Track Finder for the ATLAS Trigger

    CERN Document Server

    Mitani, Takashi; The ATLAS collaboration

    2015-01-01

    During the 2010-2012 run of Large Hadron Collider experiment, the ATLAS trigger system was successfully operated and it contributed to several important results such as observation of Higgs boson with a mass of about 125 GeV. From 2015, collision energy will increase to 13-14 TeV and its instantaneous luminosity will reach $1$-$2\\times10^{34}$cm$^{-2}$s$^{-1}$ with a 25 ns bunch crossing period. Due to the energy increase, the cross sections for SM processes are expected to get much larger. Additionally, the number of overlapping proton-proton interactions per bunch crossing, which is refereed to as pile-up, is expected to increase significantly up to about 80. Therefore it will be challenging to control trigger rates while keeping good efficiency for interesting physics events. This document summarizes the development of Fast Tracker and its tracking performance for the ATLAS experiment. The Fast Tracker is a custom electronics system that will operate at the full Level 1 accepted rate of 100 kHz and provide...

  3. On track for success: an innovative behavioral science curriculum model.

    Science.gov (United States)

    Freedy, John R; Carek, Peter J; Dickerson, Lori M; Mallin, Robert M

    2013-01-01

    This article describes the behavioral science curriculum currently in place at the Trident/MUSC Family Medicine Residency Program. The Trident/MUSC Program is a 10-10-10 community-based, university-affiliated program in Charleston, South Carolina. Over the years, the Trident/MUSC residency program has graduated over 400 Family Medicine physicians. The current behavioral science curriculum consists of both required core elements (didactic lectures, clinical observation, Balint groups, and Resident Grand Rounds) as well as optional elements (longitudinal patient care experiences, elective rotations, behavioral science editorial experience, and scholars project with a behavioral science focus). All Trident/MUSC residents complete core behavioral science curriculum elements and are free to participate in none, some, or all of the optional behavioral science curriculum elements. This flexibility allows resident physicians to tailor the educational program in a manner to meet individual educational needs. The behavioral science curriculum is based upon faculty interpretation of existing "best practice" guidelines (Residency Review Committee-Family Medicine and AAFP). This article provides sufficient curriculum detail to allow the interested reader the opportunity to adapt elements of the behavioral science curriculum to other residency training programs. While this behavioral science track system is currently in an early stage of implementation, the article discusses track advantages as well as future plans to evaluate various aspects of this innovative educational approach.

  4. Ultra-Fast Tracking Power Supply with 4th order Output Filter and Fixed-Frequency Hysteretic Control

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    A practical solution is presented for the design of a non-isolated DC/DC power converter with very low output ripple voltage and very fast output voltage step response. The converter is intended for use as an envelope tracking power supply for an RFPA (Radio Frequency Power Amplifier) in a Tetra2...

  5. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte; Jacobsen, Steffen

    2008-01-01

    BACKGROUND AND PURPOSE: Very few studies have focused on patient characteristics that influence length of stay (LOS) in fast-track total hip (THR) and knee arthroplasty (TKR). The aim of this prospective study was to identify patient characteristics associated with LOS and patient satisfaction...... aids, pre- and postoperative hemoglobin levels, the need for blood transfusion, ASA score, and time between surgery and mobilization, were all found to influence postoperative outcome in general, and LOS and patient satisfaction in particular. INTERPRETATION: We identified several patient...... characteristics that influence postoperative outcome, LOS, and patient satisfaction in our series of consecutive fast-track joint replacement patients, enabling further attention to be paid to certain aspects of surgery and rehabilitation....

  6. Readmission rates after a planned hospital stay of 2 versus 3 days in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Andersen, Jens; Hjort-Jakobsen, Dorthe; Christiansen, P. S.

    2007-01-01

    BACKGROUND: Initial programmes of fast-track open colonic surgery with a planned 2-day postoperative hospital stay have had a high readmission rate (about 20 per cent). The aim of this large, consecutive series was to compare readmission rates after a fast-track open colonic surgery programme...... from August 2004. All patients were examined 8 and 30 days after surgery. RESULTS: Readmission rates fell from 20.1 per cent in 408 patients with a planned 2-day hospital stay (period 1) to 11.3 per cent in 133 patients with a planned 3-day hospital stay (period 2) (P ... hospital stay was 2 and 3 days, median stay after readmission was 5 and 5.5 days, and median (mean) total stay was 3 (5.6) and 3 (5.7) days in periods 1 and 2 respectively. The readmission rate in period 2 was lower because there were fewer readmissions for short-term observation or social reasons...

  7. Fast-track aquifer characterization and bioremediation of groundwater

    International Nuclear Information System (INIS)

    Owen, S.B.; Erskine, J.A.; Adkisson, C.

    1995-01-01

    A short duration step-drawdown pumping test has been used to characterize a highly permeable aquifer contaminated with petroleum hydrocarbons in support of an in situ, closed loop extraction and reinjection bioremediation system for groundwater. The short-term pumping test produces a manageable quantity of contaminated groundwater while yielding a range of values for transmissivity and specific yield parameters. This range of aquifer coefficients is used in an analytical model to estimate a range of groundwater extraction rates that provide a suitable radius of influence for the extraction and reinjection system. A multi-enzyme complex catalyzed bioremediation process has been used to aerobically degrade petroleum hydrocarbons. Enzymes, amino acids, and biosurfactants are supplied to the extracted groundwater to significantly speed up the degradation by naturally occurring bacteria. During the process, amino acids promote the rapid growth of the microbial population while enzymes and bacteria attach to hydrocarbons forming a transformation state complex that degrades to fatty acids, carbon dioxide, and water. This paper presents a case study of a fast-track bioremediation using pumping test data, analytical modeling, and an enzyme technology

  8. Neural network fusion capabilities for efficient implementation of tracking algorithms

    Science.gov (United States)

    Sundareshan, Malur K.; Amoozegar, Farid

    1997-03-01

    The ability to efficiently fuse information of different forms to facilitate intelligent decision making is one of the major capabilities of trained multilayer neural networks that is now being recognized. While development of innovative adaptive control algorithms for nonlinear dynamical plants that attempt to exploit these capabilities seems to be more popular, a corresponding development of nonlinear estimation algorithms using these approaches, particularly for application in target surveillance and guidance operations, has not received similar attention. We describe the capabilities and functionality of neural network algorithms for data fusion and implementation of tracking filters. To discuss details and to serve as a vehicle for quantitative performance evaluations, the illustrative case of estimating the position and velocity of surveillance targets is considered. Efficient target- tracking algorithms that can utilize data from a host of sensing modalities and are capable of reliably tracking even uncooperative targets executing fast and complex maneuvers are of interest in a number of applications. The primary motivation for employing neural networks in these applications comes from the efficiency with which more features extracted from different sensor measurements can be utilized as inputs for estimating target maneuvers. A system architecture that efficiently integrates the fusion capabilities of a trained multilayer neural net with the tracking performance of a Kalman filter is described. The innovation lies in the way the fusion of multisensor data is accomplished to facilitate improved estimation without increasing the computational complexity of the dynamical state estimator itself.

  9. Assessment of fast and thermal neutron ambient dose equivalents around the KFUPM neutron source storage area using nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco, P. O. Box 13027, Dhahran 31311 (Saudi Arabia); Qureshi, M.A. [Center for Applied Physical Sciences, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-11-15

    A set of five {sup 241}Am-Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16Ci each and the other two are of 5Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters on their surfaces for thermal neutron detection via B10(n,{alpha})Li6 and Li6(n,{alpha})H3 nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks cm{sup -2}{mu}Sv{sup -1} and 31.5 alpha tracks cm{sup -2}{mu}Sv{sup -1}, respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as 182nSvh{sup -1} up to 10.4{mu}Svh{sup -1} whereas those for thermal neutron ranged from as low as 7nSvh{sup -1} up to 9.3{mu}Svh{sup -1}. The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and 182nSvh{sup -1} from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron

  10. Renewable energy sources and electromobility. Financial obstacles to market introduction by 2020; Erneuerbare Energien und Elektromobilitaet. Finanzielle Huerden zur Markteinfuehrung bis 2020

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Joerg; Muehlenhoff, Joerg

    2010-06-15

    This publication of the ''Agentur fuer Erneuerbare Energien'' describes why electromobility is a good thing and then proceeds to go into the financial needs of electric vehicles. Four scenarios of differential cost calculation are discussed, and conclusions are drawn for sustainable market introduction. Finally, the following questions are discussed: What is the climate protection effect of 1 million electric vehicles? How much of imported fossil fuels can be saved by 1 million electric vehicles? Is there enough power supply capacity? How can electric vehicles support the grid integration of renewable energy sources? (RHM)

  11. A fast track path improves access to palliative care for people with learning disabilities.

    Science.gov (United States)

    Whitington, Jane; Ma, Peng

    People with learning disabilities often experience inequalities in accessing general health services. This group, their families and carers need access to effective palliative care when facing a life limiting illness. This article describes the development and implementation of a fast track referral pathway for people with learning disabilities at St Francis Hospice in Essex. Our aim is to share this pathway so others can replicate the collaborative working to improve access to palliative care services for this group.

  12. Fall-related admissions after fast-track total hip and knee arthroplasty - cause of concern or consequence of success?

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kehlet, Henrik; Hip, Lundbeck Foundation Centre for Fast-track

    2013-01-01

    Total hip (THA) and knee arthroplasty (TKA) are common procedures in elderly persons, who are at potential increased risk of postoperative fall due to loss of muscle strength and impaired balance. Fast-track surgery with early mobilization and opioid-sparing analgesia have improved outcomes after...

  13. An ecologic accompanying research on the fleet test electromobility. Final report; Oekologische Begleitforschung zum Flottenversuch Elektromobilitaet. Endbericht

    Energy Technology Data Exchange (ETDEWEB)

    Helms, Heinrich; Lambrecht, Udo; Joehrens, Julius; Pehnt, Martin; Liebich, Axel; Weiss, Uta; Kaemper, Claudia

    2013-06-15

    Mobility is a prerequisite for numerous economic and private activities and thus a central component of our life. The demand for mobility in Germany is predominantly covered by the road traffic. The Institute for Energy and Environmental Research (Heidelberg, Federal Republic of Germany) carried out an ecologic accompanying research in the course of a fleet test in order to determine the potentials of environmental improvement of the vehicles tested in a field test. These potentials were perpetuated for future serial vehicles and projected to Germany. The main themes of this contribution are: (a) Production and disposal of plug-in-hybrids; (b) The TwinDrive in the fleet test; (c) Plug-in-hybrid serial vehicles 2020; (d) Perspective of electromobility in Germany 2030; (e) Strategic evaluation of the electomobility.

  14. Fast track land reform, tenure security and investments in soil conservation: Micro-evidence from Mazowe district in Zimbabwe

    NARCIS (Netherlands)

    Zikhali, P.

    2010-01-01

    The government of Zimbabwe launched the Fast Track Land Reform Programme (FTLRP) in 2000 as part of its ongoing land reform and resettlement programme which aims to address a racially skewed land distribution. Its goal has been to accelerate both land acquisition and redistribution, targeting at

  15. Fast Reactor Systems and Innovative Fuels for Minor Actinides Homogeneous Recycling

    International Nuclear Information System (INIS)

    Calabrese, R.

    2013-01-01

    The capability of nuclear energy source to limit GHG emissions at a competitive cost is still a potential driver for its development in the near- and medium-term. The sustainability of nuclear energy is concerned by various issues such as the shortage of natural uranium resources, the management of steadily increasing inventories of spent nuclear fuel as well as competitiveness. Nuclear technology should be, for its societal acceptability, affordable, safe and featured by low proliferation risks. In this regard innovative fast reactors could improve the management of spent nuclear fuel inventories a reducing the burden on the geological repository. The development of MA-bearing oxide fuels is ongoing both on the definition of under-irradiation behaviour as well as the investigations of new fabrication routes and significant efforts in R&D are necessary. This paper confirms the expected performance of investigated FRs and the synergistic use of NFCSS and DESAE proved to be capable in modelling with reasonable accuracy an innovative fuel cycle strategy. The reduction of GHG emissions by means of a steep expansion of nuclear energy needs to be carefully investigated where a multi-criteria approach is of crucial importance

  16. Fast particle tracking with wake fields

    Energy Technology Data Exchange (ETDEWEB)

    Dohlus, M.; Floettmann, K.; Henning, C.

    2012-01-15

    Tracking calculations of charged particles in electromagnetic fields require in principle the simultaneous solution of the equation of motion and of Maxwell's equations. In many tracking codes a simpler and more efficient approach is used: external fields like that of the accelerating structures are provided as field maps, generated in separate computations and for the calculation of self fields the model of a particle bunch in uniform motion is used. We describe how an externally computed wake function can be approximated by a table of Taylor coefficients and how the wake field kick can be calculated for the particle distribution in a tracking calculation. The integrated kick, representing the effect of a distributed structure, is applied at a discrete time. As an example, we use our approach to calculate the emittance growth of a bunch in an undulator beam pipe due to resistive wall wake field effects. (orig.)

  17. Multiple feature fusion via covariance matrix for visual tracking

    Science.gov (United States)

    Jin, Zefenfen; Hou, Zhiqiang; Yu, Wangsheng; Wang, Xin; Sun, Hui

    2018-04-01

    Aiming at the problem of complicated dynamic scenes in visual target tracking, a multi-feature fusion tracking algorithm based on covariance matrix is proposed to improve the robustness of the tracking algorithm. In the frame-work of quantum genetic algorithm, this paper uses the region covariance descriptor to fuse the color, edge and texture features. It also uses a fast covariance intersection algorithm to update the model. The low dimension of region covariance descriptor, the fast convergence speed and strong global optimization ability of quantum genetic algorithm, and the fast computation of fast covariance intersection algorithm are used to improve the computational efficiency of fusion, matching, and updating process, so that the algorithm achieves a fast and effective multi-feature fusion tracking. The experiments prove that the proposed algorithm can not only achieve fast and robust tracking but also effectively handle interference of occlusion, rotation, deformation, motion blur and so on.

  18. Role of preoperative pain, muscle function, and activity level in discharge readiness after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Bandholm, Thomas; Lunn, Troels Haxholdt

    2014-01-01

    therefore investigated the role of preoperative pain and functional characteristics in discharge readiness and actual LOS in fast-track THA and TKA. METHODS: Before surgery, hip pain (THA) or knee pain (TKA), lower-extremity muscle power, functional performance, and physical activity were assessed...

  19. Customer Innovation Process Leadership

    DEFF Research Database (Denmark)

    Lindgren, Peter; Jørgensen, Jacob Høj; Goduscheit, René Chester

    2007-01-01

    Innovation leadership has traditionally been focused on leading the companies' product development fast, cost effectively and with an optimal performance driven by technological inventions or by customers´ needs. To improve the efficiency of the product development process focus has been on diffe......Innovation leadership has traditionally been focused on leading the companies' product development fast, cost effectively and with an optimal performance driven by technological inventions or by customers´ needs. To improve the efficiency of the product development process focus has been...... on different types of organisational setup to the product development model and process. The globalization and enhanced competitive markets are however changing the innovation game and the challenge to innovation leadership Excellent product development innovation and leadership seems not any longer to enough...... another outlook to future innovation leadership - Customer Innovation Process Leadership - CIP-leadership. CIP-leadership moves the company's innovation process closer to the customer innovation process and discusses how companies can be involved and innovate in customers' future needs and lead...

  20. Fast Track to the Cloud: Design Patterns for 12-Factor Earth Sciences Applications

    Science.gov (United States)

    Pawloski, Andrew; McLaughlin, Brett; Lynnes, Christopher

    2016-01-01

    As expanding service offerings and decreasing prices make the cloud increasingly attractive to Earth Science applications, there are nontrivial practical considerations which can hinder its meaningful use. In this talk, we will discuss architectural recommendations and lessons learned while working on EOSDIS' cloud efforts, particularly the NASA-compliant General Application Platform (NGAP) and its associated applications. Prominent in our findings is the importance of 12-factor design patterns and the powerful "wins" they enable in the cloud. We will share our strategies for "fast-tracking" applications to the cloud --whether they be legacy, planned for the future, or somewhere in between.

  1. Early Progressive Strength Training to Enhance Recovery After Fast-Track Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Kehlet, Henrik; Husted, Henrik

    2014-01-01

    different interventions: 7 weeks of supervised physical rehabilitation with PST (PST group) and without PST (CON group) commenced early after fast-track TKA. The primary outcome was the maximal distance walked in 6 minutes (6-minute walk test). Secondary outcomes were lower extremity strength and power......, knee joint effusion and range of motion, knee pain, and self-reported disability and quality of life. All outcome measures were assessed before TKA (baseline) and 4, 8, and 26 weeks after TKA. RESULTS: There was no statistically significant difference between the PST and CON groups in the change score...

  2. Astrometry with A-Track Using Gaia DR1 Catalogue

    Science.gov (United States)

    Kılıç, Yücel; Erece, Orhan; Kaplan, Murat

    2018-04-01

    In this work, we built all sky index files from Gaia DR1 catalogue for the high-precision astrometric field solution and the precise WCS coordinates of the moving objects. For this, we used build-astrometry-index program as a part of astrometry.net code suit. Additionally, we added astrometry.net's WCS solution tool to our previously developed software which is a fast and robust pipeline for detecting moving objects such as asteroids and comets in sequential FITS images, called A-Track. Moreover, MPC module was added to A-Track. This module is linked to an asteroid database to name the found objects and prepare the MPC file to report the results. After these innovations, we tested a new version of the A-Track code on photometrical data taken by the SI-1100 CCD with 1-meter telescope at TÜBİTAK National Observatory, Antalya. The pipeline can be used to analyse large data archives or daily sequential data. The code is hosted on GitHub under the GNU GPL v3 license.

  3. Online track reconstruction at hadron colliders

    International Nuclear Information System (INIS)

    Amerio, Silvia; Bettini, Marco; Nicoletto, Marino; Crescioli, Francesco; Bucciantonio, Martina; DELL'ORSO, Mauro; Piendibene, Marco; VOLPI, Guido; Annovi, Alberto; Catastini, Pierluigi; Giannetti, Paola; Lucchesi, Donatella

    2010-01-01

    Real time event reconstruction plays a fundamental role in High Energy Physics experiments. Reducing the rate of data to be saved on tape from millions to hundreds per second is critical. In order to increase the purity of the collected samples, rate reduction has to be coupled with the capability to simultaneously perform a first selection of the most interesting events. A fast and efficient online track reconstruction is important to effectively trigger on leptons and/or displaced tracks from b-quark decays. This talk will be an overview of online tracking techniques in different HEP environments: we will show how H1 experiment at HERA faced the challenges of online track reconstruction implementing pattern matching and track linking algorithms on CAMs and FPGAs in the Fast Track Processor (FTT). The pattern recognition technique is also at the basis of the Silicon Vertex Trigger (SVT) at the CDF experiment at Tevatron: coupled to a very fast fitting phase, SVT allows to trigger on displaced tracks, thus greatly increasing the efficiency for the hadronic B decay modes. A recent upgrade of the SVT track fitter, the Giga-fitter, can perform more than 1 fit/ns and further improves the CDF online trigger capabilities at high luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the ATLAS experiment, based on the Giga-fitter architecture and designed to provide high quality tracks reconstructed over the entire detector in time for a Level-2 trigger decision.luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the Atlas experiment, based on the Giga-fitter architecture and designed to provide high

  4. Consumer guidance in product innovation: Conceptualisation of a measurement instrument for the fast-moving consumer goods industry

    DEFF Research Database (Denmark)

    Costa, Ana I. A.

    Recent meta-analysis of the impact of market-orientation on business performance yielded a significant positive correlation between market-orientation and new product performance (.35) and innovativeness (.45) (Kirca, Jayachandran & O'Bearden, 2005) Behavioral perspective of market-orientation: a......Recent meta-analysis of the impact of market-orientation on business performance yielded a significant positive correlation between market-orientation and new product performance (.35) and innovativeness (.45) (Kirca, Jayachandran & O'Bearden, 2005) Behavioral perspective of market......-orientation: a set of organizational activities that are related to the generation and dissemination of and responsiveness to market intelligence (Kohli, Jaworski & Kumar, 1993) Market-orientation comprises three behavioral components - customer-orientation, competitor-orientation and inter-functional coordination...... and innovativeness across different types of FMCG manufacturers? One way of approaching these questions in the context of innovation in the fast moving consumer goods (FMCG) industry is to apply the concept of consumer-led new product development. Consumer-led product development was introduced in the early 90's...

  5. Nurse Practitioners' attitude to nutritional challenges dealing with the patients' nutritional needs and ability to care for themselves in a fast track program

    DEFF Research Database (Denmark)

    Graarup, Jytte; Pedersen, Preben Ulrich; Bjerrum, Merete

    2014-01-01

    Background: Nutrition plays an important role to the success of fast track programs, but under nutrition are still reported. Nutritional care seems to be a low priority among nurses even though it is well-known that insufficient nutrition has severe consequences for the patients. The aim is to re......Background: Nutrition plays an important role to the success of fast track programs, but under nutrition are still reported. Nutritional care seems to be a low priority among nurses even though it is well-known that insufficient nutrition has severe consequences for the patients. The aim...... is to report to what extent a training program has made Nutritional Nurse Practitioners aware of the nutritional care for short-term hospitalized patients, and how they deal with patients’ nutritional needs and ability to provide self-care in the context of a fast track program. Methods: Deductive content...... analysis was used to analyse data from four focus group interviews. Sixteen Nutritional Nurse Practitioners from either medical or surgery wards participated. The Nutritional Nurse Practitioners were interviewed twice. The interviews were recorded and verbally transcribed. Results: In the Nutritional Nurse...

  6. Fast-track surgery: A new concept of perioperative management of surgical patients

    Directory of Open Access Journals (Sweden)

    Gabriel Rodrigues

    2013-01-01

    Full Text Available In the past few decades, surgery has advanced greatly because of an improved understanding of perioperative pathophysiology, development of minimally invasive operative techniques and advanced anaesthetic techniques. Fewer operations are requiring extended periods of hospital stay and a growing number of procedures are performed on an ambulatory basis. The pressure on medical systems is continuously growing as a result of economic constraints, increasing numbers of patients undergoing surgical procedures and greater patient autonomy. Patient awareness is steadily increasing along with their participation in their own care, leading to expectations of a higher standard of care. This has led to the development of a new concept of fast-track surgery.

  7. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte; Jacobsen, Steffen

    2008-01-01

    BACKGROUND AND PURPOSE: Very few studies have focused on patient characteristics that influence length of stay (LOS) in fast-track total hip (THR) and knee arthroplasty (TKR). The aim of this prospective study was to identify patient characteristics associated with LOS and patient satisfaction...... after total hip and knee replacement surgery. PATIENTS AND METHODS: Between September 2003 and December 2005, 712 consecutive, unselected patients (440 women) with a mean age of 69 (31-91) years were admitted for hip and knee replacement surgery at our specialized fast-track joint replacement unit....... Epidemiological, physical, and perioperative parameters were registered and correlated to LOS and patient satisfaction. RESULTS: 92% of the patients were discharged directly to their homes within 5 days, and 41% were discharged within 3 days. Age, sex, marital status, co-morbidity, preoperative use of walking...

  8. The Effects of the Fast Track Preventive Intervention on the Development of Conduct Disorder Across Childhood

    OpenAIRE

    2011-01-01

    The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social cognitive skills, reading, home visiting, mentoring, and classroom curricula. Outcomes included psychiatric diagnoses after grades 3, 6, 9, and 12 for...

  9. Fast Tracker : A Hardware Real Time Track Finder for the ATLAS Trigger System

    CERN Document Server

    Kimura, N; The ATLAS collaboration

    2013-01-01

    The Large Hadron Collider (LHC) after the 2013-­‐2014 shutdown period is expected to improve the yet impressive performance obtained up to this year: collisions’ energy will increase to 14 TeV and instantaneous luminosity will reach and then overcome 10^34 cm‐2s‐1, with a bunch crossing period of 25 ns. The LHC experiments will need to adapt to the more crowded events, maintaining the physics output and the quality of the final results. The pileup higher than the LHC run 1, with peaks expected to reach 50 or more, will make more difficult to have efficient online selection of rare events based mostly on calorimeters and muon detectors as it is done now. A more extensive use of the information collected by the tracking detector will allow building more robust selections, limiting the degradation effects due to the high pileup. We report on the development of the Fast Tracker (FTK) processor for the ATLAS experiment, devoted to reconstruct tracks with transverse momentum above 1 GeV in the whole detect...

  10. Fast TPC Online Tracking on GPUs and Asynchronous Data Processing in the ALICE HLT to facilitate Online Calibration

    International Nuclear Information System (INIS)

    Rohr, David; Gorbunov, Sergey; Krzewicki, Mikolaj; Breitner, Timo; Kretz, Matthias; Lindenstruth, Volker

    2015-01-01

    ALICE (A Large Heavy Ion Experiment) is one of the four major experiments at the Large Hadron Collider (LHC) at CERN, which is today the most powerful particle accelerator worldwide. The High Level Trigger (HLT) is an online compute farm of about 200 nodes, which reconstructs events measured by the ALICE detector in real-time. The HLT uses a custom online data-transport framework to distribute data and workload among the compute nodes.ALICE employs several calibration-sensitive subdetectors, e.g. the TPC (Time Projection Chamber). For a precise reconstruction, the HLT has to perform the calibration online. Online- calibration can make certain Offline calibration steps obsolete and can thus speed up Offline analysis. Looking forward to ALICE Run III starting in 2020, online calibration becomes a necessity.The main detector used for track reconstruction is the TPC. Reconstructing the trajectories in the TPC is the most compute-intense step during event reconstruction. Therefore, a fast tracking implementation is of great importance. Reconstructed TPC tracks build the basis for the calibration making a fast online-tracking mandatory.We present several components developed for the ALICE High Level Trigger to perform fast event reconstruction and to provide features required for online calibration.As first topic, we present our TPC tracker, which employs GPUs to speed up the processing, and which bases on a Cellular Automaton and on the Kalman filter. Our TPC tracking algorithm has been successfully used in 2011 and 2012 in the lead-lead and the proton-lead runs. We have improved it to leverage features of newer GPUs and we have ported it to support OpenCL, CUDA, and CPUs with a single common source code. This makes us vendor independent.As second topic, we present framework extensions required for online calibration. The extensions, however, are generic and can be used for other purposes as well. We have extended the framework to support asynchronous compute chains

  11. MANAJEMEN RISIKO PADA PROYEK KONSTRUKSI DENGAN METODE FAST TRACK STUDI KASUS PROYEK QUNCI VILLAS DAN PUTRI NAGA KOMODO

    Directory of Open Access Journals (Sweden)

    I Gusti Ketut Wirawan

    2015-07-01

    Full Text Available The rapid economic development such as now day, it need a construction method that may provide a facility faster and less cost. Therefore, fast track method has been widely applied in project management as happened in Qunci Villas Project at Lombok and Putri Naga Komodo Project at Loh Liang of Komodo Island. Fast track construction method has potential risks that can interfere the success of the project. This study aims to identify the risks, especially the mayor risk, to formulate the mitigation action, and to determine the risk ownership. This study was conducted using qualitative descriptive method by identifying the risks arising during the implementation of the fast track method on Qunci Villas and Putri Naga Komodo Projects through the study of literature, brainstorming, interview using questionnaires to those who knew or were involved in the project. So the frequency and magnitude of the consequences of each risk can be known. Then the risk assessment can be conducted to determine the mayor risk and the minor risk. Then determining mitigation action for the mayor risk to reduce the negative impact that may arise. Then allocating the risk ownership in other to the mitigation action can be handled properly. The risk identified totaled 25 risks consisting of : 1 risk (4% which was medium risk rating,  6 risks (24% which were high risk rating, and 18 risks (72% which were extreme risk rating. The mayor risk amounted to 24 risks (96%. The mayor risk which were high risk rating consisting of : 1 planning risk, 3 technical risks, 1 project risk and 1 criminal risk. While mayor risk which were extreme risk rating consisting of : 5 technical risks, 10 project risks, 2 financial risks, and 1 human risk. Mitigation action were handled by reducing likelihood and consequence. The most risks ownership were allocated to the contractor.

  12. National platform electromobility. Interim report of the working group 5 Materials and recycling; Nationale Plattform Elektromobilitaet. Zwischenbericht der Arbeitsgruppe 5 Materialien und Recycling

    Energy Technology Data Exchange (ETDEWEB)

    Nuessle, Falk D [ThyssenKrupp AG, Essen (Germany). Business Area Components Technology; Wissel-Stoll, Kathrin [BASF SE, Ludwigshafen (Germany). Marketing Acids and Specialties

    2010-07-01

    Sufficient range, appropriate road performances, fulfilment of ecological requirements and an alternative price structuring are challenges in order to obtain the necessary acceptance for electric-powered vehicles by the customer. For this, new materials with adapted recycling strategies have to make a substantial contribution and are a driving force to an economic and sustainable electrical mobility. In order to achieve the goal of the national platform electromobility the following key fields are success critical in this connection: (a) Material for batteries; (b) Materials for construction and material lightweight construction; (c) Concepts for securing raw materials and recycling; (d) Materials for further key components.

  13. Outcomes in smokers and alcohol users after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C C; Kehlet, Henrik; Hansen, Torben Bæk

    2013-01-01

    and knee arthroplasty. RESULTS: In 3041 consecutive patients, 458 reported smoking and 216 drinking > 2 drinks a day, of which 66 did both. Smokers/alcohol users were younger than non-users (mean age: 64.3 vs. 68.0 years, P  4 days and smoking (odds ratio [95% confidence interval], P) (1.34 [0.92-1.95], 0......BACKGROUND: Smoking and alcohol use impair post-operative outcomes. However, no studies include fast-track surgery, which is a multimodal-enhanced recovery programme demonstrated to improve outcome. We hypothesised that outcome is similar in smokers and alcohol users as in non-users after fast.......127) or alcohol use (0.59 [0.30-1.16], 0.127). Thirty- and ninety-day readmission rate was 6.6% (n = 201) and 9.4% (n = 285). Multiple logistic regression analysis showed an increased risk of readmissions in smokers at 30 (1.60 [1.05-2.44], 0.028) but not 90-day follow-up (1.17 [0.80-1.73], 0.419). No increased...

  14. Health preemption behind closed doors: trade agreements and fast-track authority.

    Science.gov (United States)

    Crosbie, Eric; Gonzalez, Mariaelena; Glantz, Stanton A

    2014-09-01

    Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies' influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. "Fast-track authority," in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests.

  15. Postoperative anemia and early functional outcomes after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, Øivind; Bandholm, Thomas; Kurbegovic, Sorel

    2016-01-01

    BACKGROUND: Postoperative anemia is prevalent in fast-track hip arthroplasty (THA) where patients are mobilized and discharged early, but whether anemia impairs functional recovery after discharge has not been adequately evaluated previously. This study aimed to evaluate whether postoperative...... anemia influenced recovery of mobility and quality of life (Qol) during the first 2 weeks after discharge from THA. STUDY DESIGN AND METHODS: This was a prospective observational study in 122 THA patients more than 65 years of age. Mobility and Qol were assessed pre- and postoperatively by the 6-minute...... walk test (6MWT; primary outcome), the timed up-and-go test, and the FACT-anemia subscale. Twenty-four-hour mobility at home was assessed by activity monitoring on Days 1 to 6 after discharge. Hemoglobin (Hb) at discharge (HbD) and the Hb decrease from preoperatively (ΔHb) were compared to mobility...

  16. 171. Funcionamiento y resultados del programa de fast-track en el tratamiento de la tetralogía de fallot

    Directory of Open Access Journals (Sweden)

    J. Orrit Palacios

    2010-01-01

    Conclusiones: La corrección completa de la tetralogía de Fallot con el programa de fast-track de anestesia disminuye la ventilación mecánica, la estancia en cuidados intensivos y el tiempo de hospitalización. Asimismo se reducen los costes económicos del tratamiento.

  17. Analysis of etchants behavior on the electrochemical etching amplification of fast-neutron-induced recoil particle tracks in polycarbonate

    International Nuclear Information System (INIS)

    Masnadi Shirazi Nezhad, K.

    1979-08-01

    The composition, concentration, and temperature of etchant are important parameters controlling electrochemical etching (ECE) amplification of charged particle tracks in polymers. These parameters were further studied for sohralir polycarbonate neutron dosimeter (Sohrabi 1974), using potassium hydroxide (KOH) and sodium hydroxide (NaOH) solutions, and a mixture of potassium hydroxide, ethanol, and water (PEW solution), at different concentrations applying a field strength of 32KV/cm at 2KHz frequency using 250 μ thick polycarbonate exposed to fast neutrons. The recoal track density per rad of neutrons, in general, was found to increase by increasing the etchant concentration reaching a semi-platean after which it increases again. This increase is up to a concentration at which a track removing process occurs and no tracks have been amplified anymore. This track removing process occurred at about 11 normality in both KOH (50% by weight) and NaOH (30% by weight) solution at 25degC. The mean track diameter, in general, passed through a cyclic variation having a maximun and a minimum. For NaOH solution, the track removing process occurred at the minimum point. In the three regions of the track diameter curve the tracks appear in different shapes especially in KOH solution. The PEW solution at its optimum conditions was more effective in terms of both sensitivity, track diameter and a shorter period of etching. The chemical mechanism of etching process may be explained to be a ''saponification'' process. These studies further support the adequacy of Sohrabi dosimeter for routing health physics and radiation research applications. The above parameters are further discussed and the results as well as the advantages and disadvantages of the above etchants are given. (author)

  18. Safety-Related Optimization and Analyses of an Innovative Fast Reactor Concept

    Directory of Open Access Journals (Sweden)

    Dalin Zhang

    2012-06-01

    Full Text Available Since a fast reactor core with uranium-plutonium fuel is not in its most reactive configuration under operating conditions, redistribution of the core materials (fuel, steel, sodium during a core disruptive accident (CDA may lead to recriticalities and as a consequence to severe nuclear power excursions. The prevention, or at least the mitigation, of core disruption is therefore of the utmost importance. In the current paper, we analyze an innovative fast reactor concept developed within the CP-ESFR European project, focusing on the phenomena affecting the initiation and the transition phases of an unprotected loss of flow (ULOF accident. Key phenomena for the initiation phase are coolant boiling onset and further voiding of the core that lead to a reactivity increase in the case of a positive void reactivity effect. Therefore, the first level of optimization involves the reduction, by design, of the positive void effect in order to avoid entering a severe accident. If the core disruption cannot be avoided, the accident enters into the transition phase, characterized by the progression of core melting and recriticalities due to fuel compaction. Dedicated features that enhance and guarantee a sufficient and timely fuel discharge are considered for the optimization of this phase.

  19. Preliminary Design of Compressor Impeller for innovative Sodium Cooled Fast Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jekyoung; Cho, Seongkuk; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Cha, Jae Eun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    For nuclear power plant application, applying S-CO{sub 2} Brayton cycle to Sodium cooled Fast Reactors and Small Modular Reactors are currently considered and active research is being performed by various research institutions and universities. As a part of research activities on the SCO{sub 2} Brayton cycle development for a nuclear power system, KAIST joint research team is currently working on an innovative Sodium cooled Fast Reactor (iSFR) development which utilizes S-CO{sub 2} Brayton cycle as its power conversion system. Various research subjects including reactor physics, thermo-hydraulics, material, cycle analysis and system integration are being considered as research issues currently. However, technical issues rising from dramatic change of thermodynamic property of CO{sub 2} near the critical point still remain as problems to be solved. As a result, 3D impeller model generation based on 1D mean stream line analysis results was successfully performed for non-airfoil blades. Since 3D model generation module works successfully, KAIST{sub T}MD can support 3D CFD analysis for internal flow structure in the designed impeller. Compressor loss mechanisms are complex phenomena and these are difficulties to be modeled while considering each loss mechanism separately.

  20. A method for the measurement of fission rates in fast neutron fields using solid state track detectors

    International Nuclear Information System (INIS)

    Hansen, W.; Vogel, W.

    1984-04-01

    Solid state track detectors (SSTDs) are increasingly used for the registration of radiation in different fields of nuclear physics. Because of their small sizes and masses and the absence of any electronics during exposure SSTDs do not cause distortions in the system to be investigated and are useful for measurements at such places being difficult of access. The elaboration of a method is described for fission rate measurements in fast neutron fields applying SSTDs and different fissionable isotopes which were electrodeposited on stainless steel backings. Experiences of the electrodeposition and results of quality checks are presented. The evaluation of the etched tracks is performed with spark counter technique. The dependence of the counting result on essential influence parameters is discussed. (author)

  1. Inhibiting Interference - a grounded theory of health professionals' pattern of behaviour related to the relatives of older patients in fast-track treatment programmes

    DEFF Research Database (Denmark)

    Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten

    2014-01-01

    AIM: To generate a grounded theory explaining health professionals' pattern of behaviour and experience related to the relatives of older patients in fast-track treatment programmes during total joint replacement. BACKGROUND: Health professionals uphold standardised care for patients, and effect...... on quality is seen when relatives support patients during total joint replacement. Since health professionals often have problematic relationships with relatives, knowledge is needed of the health professionals' pattern of behaviour in relation to relatives of older patients in fast-track treatment programme....... DESIGN: Grounded theory according to Glaser's methodology was used to generate substantive theory of health professionals' pattern of behaviour. METHODS: Data were collected from 2010 to 2011 by 44 health professionals in orthopaedic wards at two Danish hospitals. Data from nonparticipant observations...

  2. Cyclo-oxygenase 2 inhibitors and the risk of anastomotic leakage after fast-track colonic surgery

    DEFF Research Database (Denmark)

    Holte, K; Andersen, Jens; Jakobsen, D Hjort

    2009-01-01

    -oxygenase inhibitor for postoperative analgesia. METHODS: Patients with anastomotic leakage following a standard fast-track procotol between April 1997 and May 2006 were identified from a prospective, consecutive database. During this period there were two changes in perioperative management: cessation......BACKGROUND: Anastomotic leakage occurs after 3-6 per cent of colonic resections. The influence of analgesic agents is largely unknown. This study determined the rate of anastomotic leakage in a series of patients who had colonic surgery over a 9-year period with or without use of a cyclo...

  3. Health Preemption Behind Closed Doors: Trade Agreements and Fast-Track Authority

    Science.gov (United States)

    Crosbie, Eric; Gonzalez, Mariaelena

    2014-01-01

    Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies’ influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. “Fast-track authority,” in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests. PMID:25033124

  4. Measurements of fast deuterons from plasma accelerator by means of PM-355 track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Skladnik-Sadowska, E. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Malinowski, K., E-mail: k.malinowski@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Sadowski, M.J.; Czaus, K. [Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland)

    2009-10-15

    This paper reports on studies of fast ions (mostly deuterons) emitted from an RPI (Rod-Plasma-Injector) plasma accelerator. The first aim was the verification of applicability of PM-355 track detectors for dosimetry of lower-energy (<200 KeV) deuterons. The second aim was information about energy spectra of deuterons from RPI-IBIS device in different operational modes. Mass- and energy spectra of ions were investigated with a Thomson-analyzer and PM-355 detectors. On the recorded deuteron-parabolas we chose points, and from numbers of tracks we determined the deuteron energy distribution. In the slow-mode the energy distribution peak was observed at about 40 keV, while the maximum energy amounted to about 150 keV. Those measurements confirmed an influence of the initial gas-conditions on energy distributions of the deuteron streams. The results are of importance for plasma-physics and applications. Another result was the confirmation that PM-355 detectors might be used for accurate measurements of low-energy (<200 keV) deuterons.

  5. 'Fast-track' colonic surgery in Austria and Germany--results from the survey on patterns in current perioperative practice.

    Science.gov (United States)

    Hasenberg, T; Keese, M; Längle, F; Reibenwein, B; Schindler, K; Herold, A; Beck, G; Post, S; Jauch, K W; Spies, C; Schwenk, W; Shang, E

    2009-02-01

    'Fast-track' rehabilitation has been shown to accelerate recovery, reduce general morbidity and decrease hospital stay after elective colonic surgery. Despite this evidence, there is no information on the acceptance and utilization of these concepts among the entirety of Austrian and German surgeons. In 2006, a questionnaire concerning perioperative routines in elective, open colonic resection was sent to the chief surgeons of 1270 German and 120 Austrian surgical centres. The response rate was 63% in Austria (76 centres) and 30% in Germany (385 centres). Mechanical bowel preparation is used by the majority (Austria, 91%; Germany, 94%); the vertical incision is the standard method of approach to the abdomen in Austria (79%) and Germany (83%), nasogastric decompression tubes are rarely used, one-third of the questioned surgeons in both countries use intra-abdominal drains. Half of the surgical centres allow the intake of clear fluids on the day of surgery and one-fifth offer solid food on that day. Epidural analgesia is used in three-fourths of the institutions. Although there is an evident benefit of fast-track management, the survey shows that they are not yet widely used as a routine in Austria and Germany.

  6. Liminality of the »Balkan« Fast Food and Innovative Strategies of its »Europeization«: Čevapčiči with Truffles or Euro-Kebap?

    Directory of Open Access Journals (Sweden)

    Franc Trček

    2014-03-01

    Full Text Available The paper starts with the liminal state of the Balkan fast food in Slovenia and then analyzes innovative attempts of overcoming them by providers. These try to adapt its offer to our local tastes as well as to the change in tastes. In their attempts they are forced to compete with global fast food franchises. In spite of their innovative approaches, they are still in the liminal state that forces them again and again to invent of new flavors.

  7. The fast neutrons reactors, the sodium, the fuel cycle: evaluation of the knowledge, innovation potential and forecast; Les reacteurs a neutrons rapides, le sodium, le cycle du combustible: bilan de l'acquis, potentiel d'innovation et perspectives d'avenir

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, J

    2002-07-01

    This document presents the study, the design and the construction of fast neutrons reactors, cooled with sodium. From this evaluation, it details the innovation possibilities of this sector in the sustainable development context of the nuclear energy. Chapter one presents the physical and physico-chemical properties of the sodium. Chapter two analyzes the properties of the fast cores and the sodium advantages. Chapter three analyzes the great contribution of the EFR project. Chapter four takes stock on the innovation possibilities. And before the conclusion, chapter five shows that the fast neutrons reactors allow the electric power production in agreement with a sustainable development. (A.L.B.)

  8. Development Status on Innovative Sodium-Cooled Fast Reactor (JSFR)

    International Nuclear Information System (INIS)

    Yanagisawa, Tsutomu; Sato, Kazujiro

    2006-01-01

    The first step in Japan's nuclear fuel cycle policy is to introduce MOX recycle in light water reactors (LWRs) and the final step is to establish multiple TRU recycle in fast reactors (FRs), with the goal of realizing a stable supply, effective use of nuclear fuel resources, and the environmentally friendly production of energy. Therefore, a feasibility study on commercialized FR cycle systems has been launched since July 1999 by a Japanese joint project team of Japan Atomic Energy Agency (JAEA) and the Japan Atomic Power Company (JAPC: the representative of the electric utilities) in cooperation with Central Research Institute of Electric Power Industry (CRIEPI) and vendors. In the period from July 1999 to March 2001, the feasibility study phase-I was conducted to screen out representative FR cycle concepts. In the feasibility study phase-II (April 2001 - March 2006), investigations in to the representative FR concepts were carried out to clarify the most promising concept for commercial deployment. This paper describes an innovative sodium-cooled FR, which is named as the JAEA Sodium-cooled FR (JSFR), as the most promising FR concept that meets the Generation-IV performance target. The JSFR employs several advanced technologies, such as an oxide dispersion strengthened (ODS) cladding for higher burn-up, a short-piping configuration with less elbows by adopting high chromium steel, a large scale integrated intermediate heat exchanger with a primary circulation pump, etc. Based on the design, construction and operation experiences of JOYO and MONJU, there are extensive technology bases for sodium-cooled FRs. Nevertheless, several innovative technologies implemented into the JSFR have to be developed in order to realize higher economic competitiveness by reducing construction costs and improving plant availability

  9. Changing the regulation for regulating the change: Innovation-driven regulatory developments for smart grids, smart metering and e-mobility in Italy

    International Nuclear Information System (INIS)

    Lo Schiavo, Luca; Delfanti, Maurizio; Fumagalli, Elena; Olivieri, Valeria

    2013-01-01

    For a long time considered as technologically mature, electric systems are now facing a period of rapid evolution, inspired by climate change concerns. Several studies show that current regulation of natural monopolies does not offer sufficient incentives for network operators (and network users) to participate in this process. Taking Italy as a case study, this paper analyses how energy regulation can change to support the current transformation. We describe the recent regulatory interventions in the domain of smart grids, smart metering and electromobility, with a specific emphasis on the provisions aimed at fostering innovation—an issue that until recently has received almost no attention in the literature nor in the practice of regulation. The progress we observe is considerable in all new areas of concern, and, above all, in the regulator's commitment to provide the right incentives for investments in demonstration projects: the acquisition of experience is regarded as essential to move to more sophisticated regulatory instruments. Finally, regulation is also increasingly concerned with network users, both traditional and new, with the objective to stimulate more active behaviours. - Highlights: ► Regulatory changes in Italy: smart grids, smart metering and electromobility. ► Identification of indicators for regulating innovative investments. ► Demonstration projects for smart grids and EV recharging infrastructures. ► Proposal of an output-based regulation for smart grids. ► Time of Use pricing for residential and small commercial consumers

  10. Fast algorithm of track detection

    International Nuclear Information System (INIS)

    Nehrguj, B.

    1980-01-01

    A fast algorithm of variable-slope histograms is proposed, which allows a considerable reduction of computer memory size and is quite simple to carry out. Corresponding FORTRAN subprograms given a triple speed gain have been included in spiral reader data handling software

  11. Post-discharge symptoms following fast-track colonic cancer surgery: a phenomenological hermeneutic study

    DEFF Research Database (Denmark)

    Krogsgaard, Marianne; Dreyer, Pia; Egerod, Ingrid

    2014-01-01

    OBJECTIVE: To obtain knowledge of patients' experiences of postoperative symptoms during the initial two weeks following fast-track colonic cancer surgery. METHOD: Semi-structured in-depth interviews with seven colonic cancer patients two weeks post hospital discharge. Analysis was performed using...... a phenomenological hermeneutical approach. RESULTS: During the first two weeks after discharge the patients experienced unfamiliar symptoms that affected their everyday lives. Despite distressing symptoms, they applied a "wait-and-see" strategy, and only reacted when symptoms became intolerable. The patients failed...... to shorter hospitalisation and improved physical performance, post-colonic surgery patients experience various symptoms after discharge. Healthcare professionals need to address symptoms that might have immediate and long-term consequences on patients' everyday life. Follow-up studies are encouraged...

  12. Method-centered digital communities on protocols.io for fast-paced scientific innovation.

    Science.gov (United States)

    Kindler, Lori; Stoliartchouk, Alexei; Teytelman, Leonid; Hurwitz, Bonnie L

    2016-01-01

    The Internet has enabled online social interaction for scientists beyond physical meetings and conferences. Yet despite these innovations in communication, dissemination of methods is often relegated to just academic publishing. Further, these methods remain static, with subsequent advances published elsewhere and unlinked. For communities undergoing fast-paced innovation, researchers need new capabilities to share, obtain feedback, and publish methods at the forefront of scientific development. For example, a renaissance in virology is now underway given the new metagenomic methods to sequence viral DNA directly from an environment. Metagenomics makes it possible to "see" natural viral communities that could not be previously studied through culturing methods. Yet, the knowledge of specialized techniques for the production and analysis of viral metagenomes remains in a subset of labs.  This problem is common to any community using and developing emerging technologies and techniques. We developed new capabilities to create virtual communities in protocols.io, an open access platform, for disseminating protocols and knowledge at the forefront of scientific development. To demonstrate these capabilities, we present a virology community forum called VERVENet. These new features allow virology researchers to share protocols and their annotations and optimizations, connect with the broader virtual community to share knowledge, job postings, conference announcements through a common online forum, and discover the current literature through personalized recommendations to promote discussion of cutting edge research. Virtual communities in protocols.io enhance a researcher's ability to: discuss and share protocols, connect with fellow community members, and learn about new and innovative research in the field.  The web-based software for developing virtual communities is free to use on protocols.io. Data are available through public APIs at protocols.io.

  13. The fast tracker processor for hadron collider triggers

    CERN Document Server

    Annovi, A; Bardi, A; Carosi, R; Dell'Orso, Mauro; D'Onofrio, M; Giannetti, P; Iannaccone, G; Morsani, E; Pietri, M; Varotto, G

    2001-01-01

    Perspectives for precise and fast track reconstruction in future hadron collider experiments are addressed. We discuss the feasibility of a pipelined highly parallel processor dedicated to the implementation of a very fast tracking algorithm. The algorithm is based on the use of a large bank of pre-stored combinations of trajectory points, called patterns, for extremely complex tracking systems. The CMS experiment at LHC is used as a benchmark. Tracking data from the events selected by the level-1 trigger are sorted and filtered by the Fast Tracker processor at an input rate of 100 kHz. This data organization allows the level-2 trigger logic to reconstruct full resolution tracks with transverse momentum above a few GeV and search for secondary vertices within typical level-2 times. (15 refs).

  14. Direct hospital costs of total laparoscopic hysterectomy compared with fast-track open hysterectomy at a tertiary hospital: a retrospective case-controlled study.

    Science.gov (United States)

    Rhou, Yoon J J; Pather, Selvan; Loadsman, John A; Campbell, Neil; Philp, Shannon; Carter, Jonathan

    2015-12-01

    To assess the direct intraoperative and postoperative costs in women undergoing total laparoscopic hysterectomy and fast-track open hysterectomy. A retrospective review of the direct hospital-related costs in a matched cohort of women undergoing total laparoscopic hysterectomy (TLH) and fast-track open hysterectomy (FTOH) at a tertiary hospital. All costs were calculated, including the cost of advanced high-energy laparoscopic devices. The effect of the learning curve on cost in laparoscopic hysterectomy was also assessed, as was the hospital case-weighted cost, which was compared with the actual cost. Fifty women were included in each arm of the study. TLH had a higher intraoperative cost, but a lower postoperative cost than FTOH (AUD$3877 vs AUD$2776 P funding model in our hospital is inaccurate when compared to directly calculated hospital costs. © 2013 The Authors ANZJOG © 2013 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  15. The French Fast Reactor Program - Innovations in Support to Higher Standards

    International Nuclear Information System (INIS)

    Gauché, François

    2013-01-01

    • From the experience of ASTRID first phase of conceptual design studies (2010-2012), two remarks can be made: → Higher requirements in safety and operability lead to higher costs that cannot be fully recovered by advances in technology. This puts additional pressure on the next phases of the design to optimize the design and to keep the costs to the minimum. → There is a clear link between the level of safety that can be achieved and the maturity of the technology, i.e. the experience accumulated in R&D, design, construction, operation and decommissioning of past reactors. In the field of fast neutron reactors, this gives a strong advantage to the sodium technology, because strengths and weaknesses are well mastered. • Meeting the high requirements set for ASTRID and serving R&D needs of innovative options will require increased industrial and international collaboration

  16. Innovation and Outdoor Education

    Science.gov (United States)

    Beames, Simon

    2017-01-01

    Within our fast-paced, fluid society, it is arguable that outdoor education needs to be innovative to play a useful role in young people's overall educational enterprise. A critical view, however, would suggest that we must beware of accepting technological innovation for its own sake. Innovations (or improvements) in education can take the form…

  17. Innovative technologies on fuel assemblies cleaning for sodium fast reactors: First considerations on cleaning process

    International Nuclear Information System (INIS)

    Simon, N.; Lorcet, H.; Beauchamp, F.; Guigues, E.; Lovera, P.; Fleche, J. L.; Lacroix, M.; Carra, O.; Dechelette, F.; Prele, G.; Rodriguez, G.

    2012-01-01

    Within the framework of Sodium Fast Reactor development, innovative fuel assembly cleaning operations are investigated to meet the GEN IV goals of safety and of process development. One of the challenges is to mitigate the Sodium Water Reaction currently used in these processes. The potential applications of aqueous solutions of mineral salts (including the possibility of using redox chemical reactions) to mitigate the Sodium Water Reaction are considered in a first part and a new experimental bench, dedicated to this study, is described. Anhydrous alternative options based on Na/CO 2 interaction are also presented. Then, in a second part, a functional study conducted on the cleaning pit is proposed. Based on experimental feedback, some calculations are carried out to estimate the sodium inventory on the fuel elements, and physical methods like hot inert gas sweeping to reduce this inventory are also presented. Finally, the implementation of these innovative solutions in cleaning pits is studied in regard to the expected performances. (authors)

  18. Innovative technologies on fuel assemblies cleaning for sodium fast reactors: First considerations on cleaning process

    Energy Technology Data Exchange (ETDEWEB)

    Simon, N.; Lorcet, H.; Beauchamp, F.; Guigues, E. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France); Lovera, P.; Fleche, J. L. [CEA, DEN, DPC Saclay, F-91191 Gif-sur-Yvette (France); Lacroix, M. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France); Carra, O. [AREVA / NP, 10 Rue Juliette Recamier, 69003 Lyon (France); Dechelette, F. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France); Prele, G. [EDF/SEPTEN, 12-14 avenue Dutrievoz, 69628 Villeurbane Cedex (France); Rodriguez, G. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France)

    2012-07-01

    Within the framework of Sodium Fast Reactor development, innovative fuel assembly cleaning operations are investigated to meet the GEN IV goals of safety and of process development. One of the challenges is to mitigate the Sodium Water Reaction currently used in these processes. The potential applications of aqueous solutions of mineral salts (including the possibility of using redox chemical reactions) to mitigate the Sodium Water Reaction are considered in a first part and a new experimental bench, dedicated to this study, is described. Anhydrous alternative options based on Na/CO{sub 2} interaction are also presented. Then, in a second part, a functional study conducted on the cleaning pit is proposed. Based on experimental feedback, some calculations are carried out to estimate the sodium inventory on the fuel elements, and physical methods like hot inert gas sweeping to reduce this inventory are also presented. Finally, the implementation of these innovative solutions in cleaning pits is studied in regard to the expected performances. (authors)

  19. Simultaneous nuclear data target accuracy study for innovative fast reactors

    International Nuclear Information System (INIS)

    Aliberti, G.; Palmiotti, G.; Salvatores, M.

    2007-01-01

    The present paper summarizes the major outcomes of a study conducted within a Nuclear Energy Agency Working Party on Evaluation Cooperation (NEA WPEC) initiative aiming to investigate data needs for future innovative nuclear systems, to quantify them and to propose a strategy to meet them. Within the NEA WPEC Subgroup 26 an uncertainty assessment has been carried out using covariance data recently processed by joint efforts of several US and European Labs. In general, the uncertainty analysis shows that for the wide selection of fast reactor concepts considered, the present integral parameters uncertainties resulting from the assumed uncertainties on nuclear data are probably acceptable in the early phases of design feasibility studies. However, in the successive phase of preliminary conceptual designs and in later design phases of selected reactor and fuel cycle concepts, there will be the need for improved data and methods, in order to reduce margins, both for economic and safety reasons. It is then important to define as soon as possible priority issues, i.e. which are the nuclear data (isotope, reaction type, energy range) that need improvement, in order to quantify target accuracies and to select a strategy to meet the requirements needed (e.g. by some selected new differential measurements and by the use of integral experiments). In this context one should account for the wide range of high accuracy integral experiments already performed and available in national or, better, international data basis, in order to indicate new integral experiments that will be needed to account for new requirements due to innovative design features, and to provide the necessary full integral data base to be used for validation of the design simulation tools.

  20. Measured and calculated absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion

    International Nuclear Information System (INIS)

    Jensen, M.; Mathiesen, O.

    1975-04-01

    A modified form of the delta-ray theory of track formation developed by Katz and coworkers has been used to calculate the absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion. The theoretical data have been compared with results of different photometrical investigations reported in the literature. In most cases the theoretical predictions are found to be in good agreement with experiments. This suggests that the theory can be used in the planning and execution of future experiments, i.e. to optimize the geometry of the photometer and to obtain an absolute charge calibration of the detector. It is shown that the basic photometrical properties of an emulsion stack can be described by a single quantity which can be determined from measurements. Knowing this quantity it is possible to predict the response of the emulsion stack for different types of photometers. The practical limits of the use of the modified theory at high and low levels of energy dose are discussed. (Auth.)

  1. Measured and calculated absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion

    International Nuclear Information System (INIS)

    Jensen, M.; Mathiesen, O.

    1976-01-01

    A modified form of the delta-ray theory of track formation developed by Katz and coworkers has been used to calculate the absorptance of tracks of fast heavy ions in Ilford G5 nuclear emulsion. The theoretical data have been compared with results of different photometrical investigations reported in the literature. In most cases the theoretical predictions are found to be in good agreement with experiments. This suggests that the theory can be used in the planning and execution of future experiments, i.e. to optimize the geometry of the photometer and to obtain an absolute charge calibration of the detector. It is shown that the basic photometrical properties of an emulsion stack can be described by a single quantity which can be determined from measurements. Knowing this quantity it is possible to predict the response of the detector system, for different types of photometers. The practical limits of the use of the modified theory at high and low levels of energy dose are discussed. (Auth.)

  2. Assessing the functions and dimensions of visualizations in foresight

    DEFF Research Database (Denmark)

    Müller, Adrian W.; Schwarz, Jan Oliver

    -researchers, designers and innovation strategist, was to assess how visualization of foresight results can be applied, reflecting on different purposes and context. The study based insights are then applied to a comprehensive foresight project case in context of electromobility in Switzerland....

  3. Thermal-hydraulic analysis of an innovative decay heat removal system for lead-cooled fast reactors

    International Nuclear Information System (INIS)

    Giannetti, Fabio; Vitale Di Maio, Damiano; Naviglio, Antonio; Caruso, Gianfranco

    2016-01-01

    Highlights: • LOOP thermal-hydraulic transient analysis for lead-cooled fast reactors. • Passive decay heat removal system concept to avoid lead freezing. • Solution developed for the diversification of the decay heat removal functions. • RELAP5 vs. RELAP5-3D comparison for lead applications. - Abstract: Improvement of safety requirements in GEN IV reactors needs more reliable safety systems, among which the decay heat removal system (DHR) is one of the most important. Complying with the diversification criteria and based on pure passive and very reliable components, an additional DHR for the ALFRED reactor (Advanced Lead Fast Reactor European Demonstrator) has been proposed and its thermal-hydraulic performances are analyzed. It consists in a coupling of two innovative subsystems: the radiative-based direct heat exchanger (DHX), and the pool heat exchanger (PHX). Preliminary thermal-hydraulic analyses, by using RELAP5 and RELAP5-3D© computer programs, have been carried out showing that the whole system can safely operate, in natural circulation, for a long term. Sensitivity analyses for: the emissivity of the DHX surfaces, the PHX water heat transfer coefficient (HTC) and the lead HTC have been carried out. In addition, the effects of the density variation uncertainty on the results has been analyzed and compared. It allowed to assess the feasibility of the system and to evaluate the acceptable range of the studied parameters. A comparison of the results obtained with RELAP5 and RELAP5-3D© has been carried out and the analysis of the differences of the two codes for lead is presented. The features of the innovative DHR allow to match the decay heat removal performance with the trend of the reactor decay heat power after shutdown, minimizing at the same time the risk of lead freezing. This system, proposed for the diversification of the DHR in the LFRs, could be applicable in the other pool-type liquid metal fast reactors.

  4. Thermal-hydraulic analysis of an innovative decay heat removal system for lead-cooled fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Giannetti, Fabio; Vitale Di Maio, Damiano; Naviglio, Antonio; Caruso, Gianfranco, E-mail: gianfranco.caruso@uniroma1.it

    2016-08-15

    Highlights: • LOOP thermal-hydraulic transient analysis for lead-cooled fast reactors. • Passive decay heat removal system concept to avoid lead freezing. • Solution developed for the diversification of the decay heat removal functions. • RELAP5 vs. RELAP5-3D comparison for lead applications. - Abstract: Improvement of safety requirements in GEN IV reactors needs more reliable safety systems, among which the decay heat removal system (DHR) is one of the most important. Complying with the diversification criteria and based on pure passive and very reliable components, an additional DHR for the ALFRED reactor (Advanced Lead Fast Reactor European Demonstrator) has been proposed and its thermal-hydraulic performances are analyzed. It consists in a coupling of two innovative subsystems: the radiative-based direct heat exchanger (DHX), and the pool heat exchanger (PHX). Preliminary thermal-hydraulic analyses, by using RELAP5 and RELAP5-3D© computer programs, have been carried out showing that the whole system can safely operate, in natural circulation, for a long term. Sensitivity analyses for: the emissivity of the DHX surfaces, the PHX water heat transfer coefficient (HTC) and the lead HTC have been carried out. In addition, the effects of the density variation uncertainty on the results has been analyzed and compared. It allowed to assess the feasibility of the system and to evaluate the acceptable range of the studied parameters. A comparison of the results obtained with RELAP5 and RELAP5-3D© has been carried out and the analysis of the differences of the two codes for lead is presented. The features of the innovative DHR allow to match the decay heat removal performance with the trend of the reactor decay heat power after shutdown, minimizing at the same time the risk of lead freezing. This system, proposed for the diversification of the DHR in the LFRs, could be applicable in the other pool-type liquid metal fast reactors.

  5. Online tracking applications of the general purpose EDRO Board

    CERN Document Server

    Annovi, A; The ATLAS collaboration; Cervini, F; Crescioli, F; Fabbri, L; Franchini, M; Giannetti, P; Giannuzzi, F; Giorgi, F; Magalotti, D; Piendibene, M; Sbarra, C; Valentinetti, S; Mauro, V; Zoccoli, A

    2012-01-01

    The capability to perform extremely fast track reconstruction online is becoming more and more important for the LHC upgrade as well as the next generation of HEP experiments, where the expected instantaneous luminosities (in excess of 10^34 /cm2/s) and the very low signal/background ratio ask for fast and clean identification of the main characteristics of interesting events. The Slim5 R&D project studied different aspects of fast and high-precision tracking in dedicated hardware: data-push silicon sensors, high bandwidth DAQ systems and Associative Memories (AM) for fast track identification. The central element of the development system is a high traffic board, called EDRO, capable of collecting and processing digital data with an input rate of 16 Gbps. The input hits, suitably formatted or clusterized, are sent to an AM board sending back candidate tracks, which are identified at a rate of 40 MHz. The EDRO board is then able to deliver triggers and formatted events for further processing. The EDRO-AM ...

  6. A self seeded first level track trigger for ATLAS

    International Nuclear Information System (INIS)

    Schöning, A

    2012-01-01

    For the planned high luminosity upgrade of the Large Hadron Collider, aiming to increase the instantaneous luminosity to 5 × 10 34 cm −2 s −1 , the implementation of a first level track trigger has been proposed. This trigger could be installed in the year ∼ 2021 along with the complete renewal of the ATLAS inner detector. The fast readout of the hit information from the Inner Detector is considered as the main challenge of such a track trigger. Different concepts for the implementation of a first level trigger are currently studied within the ATLAS collaboration. The so called 'Self Seeded' track trigger concept exploits fast frontend filtering algorithms based on cluster size reconstruction and fast vector tracking to select hits associated to high momentum tracks. Simulation studies have been performed and results on efficiencies, purities and trigger rates are presented for different layouts.

  7. The Mass Tracking System for the Integral Fast Reactor fuel cycle

    International Nuclear Information System (INIS)

    Adams, C.H.; Beitel, J.C.; Birgersson, G.; Bucher, R.G.; Carrico, C.B.; Daly, T.A.; Keyes, R.W.

    1994-01-01

    As part of the Fuel Cycle Facility (FCF) of Argonne National Laboratory's Integral Fast Reactor (IFR) demonstration, a computer-based Mass-Tracking (MTG) System has been developed. The MTG System collects, stores, retrieves and processes data on all operations which directly affect the flow of process material through FCF and supports such activities as process modeling, compliance with operating limits (e.g., criticality safety), material control and accountability and operational information services. Its architecture is client/server, with input and output connections to operator's equipment-control stations on the floor of FCF as well as to terminal sessions. Its heterogeneous database includes a relational-database manager as well as both binary and ASCII data files. The design of the database, and the software that supports it, is based on a model of discrete accountable items distributed in space and time and constitutes a complete historical record of the material processed in FCF. Although still under development, much of the MTG System has been qualified and is in production use

  8. The Diffusion of Innovation in Language Teaching.

    Science.gov (United States)

    Markee, Numa

    1992-01-01

    The last 20 years in applied linguistics have seen the evolution of the communicative approach in language teaching and the development of a number of language teaching innovations. Investigating the problems associated with implementing these innovations is essential. Frameworks for evaluating and tracking the diffusion of innovations are…

  9. The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

    International Nuclear Information System (INIS)

    Weisshaar, D.; Bazin, D.; Bender, P.C.; Campbell, C.M.; Recchia, F.; Bader, V.; Baugher, T.; Belarge, J.; Carpenter, M.P.; Crawford, H.L.; Cromaz, M.; Elman, B.; Fallon, P.; Forney, A.; Gade, A.

    2017-01-01

    The γ-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The γ-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the γ-ray analysis in terms of Doppler reconstruction and spectral quality. The results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

  10. The performance of the γ-ray tracking array GRETINA for γ-ray spectroscopy with fast beams of rare isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Weisshaar, D., E-mail: weisshaar@nscl.msu.edu [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Bazin, D. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Bender, P.C. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Campbell, C.M. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Recchia, F. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Bader, V.; Baugher, T. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Belarge, J. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Carpenter, M.P. [Argonne National Laboratory, Argonne, IL 60439 (United States); Crawford, H.L.; Cromaz, M. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Elman, B. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Fallon, P. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Forney, A. [Department of Chemistry and Biochemistry, University of Maryland, College Park, MD 20742 (United States); Gade, A. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); and others

    2017-03-01

    The γ-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The γ-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the γ-ray analysis in terms of Doppler reconstruction and spectral quality. The results reported in this work were obtained from GRETINA consisting of 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.

  11. Laparoscopy in combination with fast track multimodal management is the best perioperative strategy in patients undergoing colonic surgery: a randomized clinical trial (LAFA-study)

    NARCIS (Netherlands)

    Vlug, Malaika S.; Wind, Jan; Hollmann, Markus W.; Ubbink, Dirk T.; Cense, Huib A.; Engel, Alexander F.; Gerhards, Michael F.; van Wagensveld, Bart A.; van der Zaag, Edwin S.; van Geloven, Anna A. W.; Sprangers, Mirjam A. G.; Cuesta, Miguel A.; Bemelman, Willem A.; Preckel, Benedikt; Bossuyt, Patrick; Gouma, Dirk; van Berge Henegouwen, Mark; Fuhring, Jan; van Lenthe, Ineke Picard; Bakker, Chris; King-Kalimanis, Bellinda; Hofland, Jan; Dejong, Cornelis; van Dam, Ronald; van der Peet, Donald; van Zalingen, Edith; Noordhuis, Astrid; de Jong, Dick; Goei, T. Hauwy; de Stoppelaar, Erica; van den Dongen, Marjon; van Tets, Willem; van den Elsen, Maarten; Swart, Annemiek; deWit, Laurens; Siepel, Muriel; Molly, Glaresa; Juttmann, Jan; Clevers, Wilfred; Bieleman, Andrea; Coenen, Ludo; Bonekamp, Elly; van Abeelen, Jacobus; van Iterson-de Jong, Diana; Krombeen, Margriet

    2011-01-01

    To investigate which perioperative treatment, ie, laparoscopic or open surgery combined with fast track (FT) or standard care, is the optimal approach for patients undergoing segmental resection for colon cancer. Important developments in elective colorectal surgery are the introduction of

  12. Testbeam results of the first real-time embedded tracking system with artificial retina

    Energy Technology Data Exchange (ETDEWEB)

    Neri, N., E-mail: nicola.neri@mi.infn.it; Abba, A.; Caponio, F.; Citterio, M.; Coelli, S.; Fu, J.; Merli, A.; Monti, M.; Petruzzo, M.

    2017-02-11

    We present the testbeam results of the first real-time embedded tracking system based on artificial retina algorithm. The tracking system prototype is capable of fast track reconstruction with a latency of the response below 1 μs and track parameter resolutions that are comparable with the offline results. The artificial retina algorithm was implemented in hardware in a custom data acquisition board based on commercial FPGA. The system was tested successfully using a 180 GeV/c proton beam at the CERN SPS with a maximum track rate of about 280 kHz. Online track parameters were found in good agreement with offline results and with the simulated response. - Highlights: • First real-time tracking system based on artificial retina algorithm tested on beam. • Fast track reconstruction within one microsecond latency and offline like quality. • Fast tracking algorithm implemented in commercial FPGAs.

  13. What Is Required to End the AIDS Epidemic as a Public Health Threat by 2030? The Cost and Impact of the Fast-Track Approach.

    Directory of Open Access Journals (Sweden)

    John Stover

    Full Text Available In 2011 a new Investment Framework was proposed that described how the scale-up of key HIV interventions could dramatically reduce new HIV infections and AIDS-related deaths in low and middle income countries by 2015. This framework included ambitious coverage goals for prevention and treatment services for 2015, resulting in a reduction of new HIV infections by more than half, in line with the goals of the declaration of the UN High Level Meeting in June 2011. However, the approach suggested a leveling in the number of new infections at about 1 million annually-far from the UNAIDS goal of ending AIDS by 2030. In response, UNAIDS has developed the Fast-Track approach that is intended to provide a roadmap to the actions required to achieve this goal. The Fast-Track approach is predicated on a rapid scale-up of focused, effective prevention and treatment services over the next 5 years and then maintaining a high level of programme implementation until 2030. Fast-Track aims to reduce new infections and AIDS-related deaths by 90% from 2010 to 2030 and proposes a set of biomedical, behavioral and enabling intervention targets for 2020 and 2030 to achieve that goal, including the rapid scale-up initiative for antiretroviral treatment known as 90-90-90. Compared to a counterfactual scenario of constant coverage for all services at early-2015 levels, the Fast-Track approach would avert 18 million HIV infections and 11 million deaths from 2016 to 2030 globally. This paper describes the analysis that produced these targets and the estimated resources needed to achieve them in low- and middle-income countries. It indicates that it is possible to achieve these goals with a significant push to achieve rapid scale-up of key interventions between now and 2020. The annual resources required from all sources would rise to US$7.4Bn in low-income countries, US$8.2Bn in lower middle-income countries and US$10.5Bn in upper-middle-income-countries by 2020 before

  14. Materials challenges supporting new sodium fast reactor designs

    International Nuclear Information System (INIS)

    Gelineau, O.; Goff, S. Dubiez-le; Dubuisson, Ph.; Dalle, F.; Blat, M.

    2009-01-01

    Sodium Fast Reactor is considered in France as the most mature technology of the different Generation IV systems. In the short-term the designing work is focused on the identification of the potential tracks to improve competitiveness, safety, efficiency and to reduce cost. In that frame the materials have a key role to play. This paper is focused on the new materials envisaged and on the Research and Development program launched in France by Areva NP, CEA and EDF in order to sustain the innovative design options: ferritic steels as candidates for exchangers, steam generators and possibly sodium circuits, optimization of materials and fabrication processes to improve safety and risk management, extension of material databases to take into account the 60 years life duration including irradiation and ageing effect. (author)

  15. Radiation-hardened fast acquisition/weak signal tracking system and method

    Science.gov (United States)

    Winternitz, Luke (Inventor); Boegner, Gregory J. (Inventor); Sirotzky, Steve (Inventor)

    2009-01-01

    A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.

  16. Quantifying the factors influencing people’s car type choices in Europe: Results of a stated preference survey

    OpenAIRE

    GOMEZ VILCHEZ JONATAN; HARRISON GILLIAN; KELLEHER LUKE; SMYTH AUSTIN; THIEL CHRISTIAN

    2017-01-01

    This study aims at tracking the evolution of the attitude of car drivers towards electro-mobility. The results of a new survey conducted in six European countries are shown. The purchase price continues to represent the major hurdle to widespread adoption of zero tailpipe emission cars.

  17. A Hardware Fast Tracker for the ATLAS Trigger: The Fast TracKer (FTK) Project.

    CERN Document Server

    Asbah, Nedaa; The ATLAS collaboration

    2015-01-01

    The trigger system of the ATLAS experiment is designed to reduce the event rate from the LHC nominal bunch crossing at 40 MHz to about 1 kHz, at the design luminosity of 10^{34} cm^{-2} s{-1}. After a successful period of data taking from 2010 to early 2013, the LHC is restarting in 2015 with much higher instantaneous luminosity and this will increase the load on High Level Trigger system, the second stage of the selection based on software algorithms. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals. The Fast TracKer is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide, at every level-1 accept (100 kHz) and within 100 microseconds, full tracking information for tracks with momentum as low as 1 GeV. Providing fast extensive access to tracking information, with resolution comparable to the offline reconstruction, the Fast Tracker will for example help the High Level Trigger...

  18. Fast Filter Central Drift Chamber Program. MAC Note 404

    International Nuclear Information System (INIS)

    Ford, W.T.

    1979-01-01

    A fast filter of the central detector tracking program was developed and tested. The search for tracks is conducted as in the full linking program - from the outermost layer hit to the next layer in. Any hit is accepted within a road centered which is large enough to allow for stero displacement and any curvature. With the fast filter, this is continued to the innermost layer, with five or more hits accepted as a track

  19. Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning

    International Nuclear Information System (INIS)

    Dowling, J; Chandra, S; Dang, K; Fox, Chris D; Gill, Suki; Kron, T; Pham, D; Foroudi, F

    2014-01-01

    The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, p<0.001) for all organs and the difference generally less than 1mm. For prostate planning peristalsis and rectal gas can result in unpredictable out of plane motion, suggesting the results may require manual verification.

  20. The CDF II eXtremely fast tracker upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Abulencia, A.; Azzurri, P.; Cochran, E.; Dittmann, J.; Donati, S.; Efron, J.; Erbacher, R.; Errede, D.; Fedorko, I.; Flanagan, G.; Forrest, R.; /Illinois U., Urbana

    2006-09-01

    The CDF II Extremely Fast Tracker is the trigger track processor which reconstructs charged particle tracks in the transverse plane of the CDF II central outer tracking chamber. The system is now being upgraded to perform a three dimensional track reconstruction. A review of the upgrade is presented here.

  1. Study of hardware implementations of fast tracking algorithms

    International Nuclear Information System (INIS)

    Song, Z.; Huang, G.; Wang, D.; Lentdecker, G. De; Dong, J.; Léonard, A.; Robert, F.; Yang, Y.

    2017-01-01

    Real-time track reconstruction at high event rates is a major challenge for future experiments in high energy physics. To perform pattern-recognition and track fitting, artificial retina or Hough transformation methods have been introduced in the field which have to be implemented in FPGA firmware. In this note we report on a case study of a possible FPGA hardware implementation approach of the retina algorithm based on a Floating-Point core. Detailed measurements with this algorithm are investigated. Retina performance and capabilities of the FPGA are discussed along with perspectives for further optimization and applications.

  2. Evaluation of the influence of pulmonary hypertension in ultra-fast-track anesthesia technique in adult patients undergoing cardiac surgery

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio da Silva

    2015-08-01

    Full Text Available Abstract Objective: To evaluate the influence of pulmonary hypertension in the ultra-fast-track anesthesia technique in adult cardiac surgery. Methods: A retrospective study. They were included 40 patients divided into two groups: GI (without pulmonary hypertension and GII (with pulmonary hypertension. Based on data obtained by transthoracic echocardiography. We considered as the absence of pulmonary hypertension: a pulmonary artery systolic pressure (sPAP 40 mmHg associated with additional echocardiographic signs of PH. It was established as influence of pulmonary hypertension: the impossibility of extubation in the operating room, the increase in the time interval for extubation and reintubation the first 24 hours postoperatively. Univariate and multivariate analyzes were performed when necessary. Considered significant a P value <0.05. Results: The GI was composed of 21 patients and GII for 19. All patients (100% were extubated in the operating room in a medium time interval of 17.58±8.06 min with a median of 18 min in GII and 17 min in GI. PH did not increase the time interval for extubation (P=0.397. It required reintubation of 2 patients in GII (5% of the total, without statistically significant as compared to GI (P=0.488. Conclusion: In this study, pulmonary hypertension did not influence on ultra-fast-track anesthesia in adult cardiac surgery.

  3. Bellcord: a multilevel fast preprocessor for 1024 ECL channels

    International Nuclear Information System (INIS)

    Kerns, C.R.

    1978-01-01

    To provide a fast decision trigger on multiple tracks passing through multiwire proportional chambers, a high-speed (arriving at an answer in 60 ns) track counting system was developed at Fermilab. The circuit is capable of selecting the track multiplicities utilizing a coaxial cable ''Bus'' (the Bellcord) on which fast pulses are summed. Up to 16 Bellcord coax cables, each having 64 inputs, are fanned into a central ''Hub'' processor where the trigger level decision is made. 7 figures

  4. ATLAS FTK: The Fast Tracker

    CERN Document Server

    T, Iizawa; The ATLAS collaboration

    2014-01-01

    The Fast TracKer (FTK) will perform global track reconstruction after each Level-1 trigger accept to enable the software-based High Level Trigger to have early access to tracking information. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful Field Programmable Gate Arrays (FPGAs) form an important part of the system architecture, and the large level of computing power required for pattern recognition is provided by incorporating standard-cell ASICs named Associative Memory (AM). FTK provides global track reconstruction in the full inner silicon detector in approximately 100 microseconds with resolution comparable to the offline algorithms. It allows a fast and precise detection of the primary and secondary vertex information. The track and vertex information is then used by the High Level Trigger algorithms, allowing highly improved trigger performance for the important signatures such as b-jets. In this paper, the architecture and the hardware development status of FT...

  5. The fast tracker processor for hadronic collider triggers

    CERN Document Server

    Annovi, A; Bardi, A; Carosi, R; Dell'Orso, Mauro; D'Onofrio, M; Giannetti, P; Iannaccone, G; Morsani, F; Pietri, M; Varotto, G

    2000-01-01

    Perspective for precise and fast track reconstruction in future hadronic collider experiments are addressed. We discuss the feasibility of a pipelined highly parallelized processor dedicated to the implementation of a very fast algorithm. The algorithm is based on the use of a large bank of pre-stored combinations of trajectory points (patterns) for extremely complex tracking systems. The CMS experiment at LHC is used as a benchmark. Tracking data from the events selected by the level-1 trigger are sorted and filtered by the Fast Tracker processor at a rate of 100 kHz. This data organization allows the level-2 trigger logic to reconstruct full resolution traces with transverse momentum above few GeV and search secondary vertexes within typical level-2 times. 15 Refs.

  6. Detection of a faint fast-moving near-Earth asteroid using the synthetic tracking technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Chengxing; Shao, Michael; Nemati, Bijan; Werne, Thomas; Zhou, Hanying; Turyshev, Slava G.; Sandhu, Jagmit [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Hallinan, Gregg; Harding, Leon K., E-mail: chengxing.zhai@jpl.nasa.gov [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2014-09-01

    We report a detection of a faint near-Earth asteroid (NEA) using our synthetic tracking technique and the CHIMERA instrument on the Palomar 200 inch telescope. With an apparent magnitude of 23 (H = 29, assuming detection at 20 lunar distances), the asteroid was moving at 6.°32 day{sup –1} and was detected at a signal-to-noise ratio (S/N) of 15 using 30 s of data taken at a 16.7 Hz frame rate. The detection was confirmed by a second observation 77 minutes later at the same S/N. Because of its high proper motion, the NEA moved 7 arcsec over the 30 s of observation. Synthetic tracking avoided image degradation due to trailing loss that affects conventional techniques relying on 30 s exposures; the trailing loss would have degraded the surface brightness of the NEA image on the CCD down to an approximate magnitude of 25 making the object undetectable. This detection was a result of our 12 hr blind search conducted on the Palomar 200 inch telescope over two nights, scanning twice over six (5.°3 × 0.°046) fields. Detecting only one asteroid is consistent with Harris's estimates for the distribution of the asteroid population, which was used to predict a detection of 1.2 NEAs in the H-magnitude range 28-31 for the two nights. The experimental design, data analysis methods, and algorithms are presented. We also demonstrate milliarcsecond-level astrometry using observations of two known bright asteroids on the same system with synthetic tracking. We conclude by discussing strategies for scheduling observations to detect and characterize small and fast-moving NEAs using the new technique.

  7. The design and simulated performance of a fast Level 1 track trigger for the ATLAS High Luminosity Upgrade

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the High Luminosity LHC will face a fivefold increase in the number of interactions per bunch crossing relative to the ongoing Run 2. This will require a proportional improvement in rejection power at the earliest levels of the detector trigger system, while preserving good signal efficiency. One critical aspect of this improvement will be the implementation of precise track reconstruction, through which sharper trigger turn-on curves can be achieved, and b-tagging and tau-tagging techniques can in principle be implemented. The challenge of such a project comes in the development of a fast, custom electronic device integrated in the hardware based first trigger level of the experiment. This article will discuss the requirements, architecture and projected performance of the system in terms of tracking, timing and physics, based on detailed simulations. Studies are carried out using data from the strip subsystem only or both strip and pixel subsystems.

  8. The design and simulated performance of a fast Level 1 track trigger for the ATLAS High Luminosity Upgrade

    CERN Document Server

    Martensson, Mikael; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the high-luminosity LHC will face a five-fold increase in the number of interactions per collision relative to the ongoing Run 2. This will require a proportional improvement in rejection power at the earliest levels of the detector trigger system, while preserving good signal efficiency. One critical aspect of this improvement will be the implementation of precise track reconstruction, through which sharper trigger turn-on curves can be achieved, and b-tagging and tau-tagging techniques can in principle be implemented. The challenge of such a project comes in the development of a fast, custom electronic device integrated in the hardware-based first trigger level of the experiment, with repercussions propagating as far as the detector read-out philosophy. This talk will discuss the requirements, architecture and projected performance of the system in terms of tracking, timing and physics, based on detailed simulations. Studies are carried out comparing two detector geometries and using...

  9. Decontaminate feature for tracking: adaptive tracking via evolutionary feature subset

    Science.gov (United States)

    Liu, Qiaoyuan; Wang, Yuru; Yin, Minghao; Ren, Jinchang; Li, Ruizhi

    2017-11-01

    Although various visual tracking algorithms have been proposed in the last 2-3 decades, it remains a challenging problem for effective tracking with fast motion, deformation, occlusion, etc. Under complex tracking conditions, most tracking models are not discriminative and adaptive enough. When the combined feature vectors are inputted to the visual models, this may lead to redundancy causing low efficiency and ambiguity causing poor performance. An effective tracking algorithm is proposed to decontaminate features for each video sequence adaptively, where the visual modeling is treated as an optimization problem from the perspective of evolution. Every feature vector is compared to a biological individual and then decontaminated via classical evolutionary algorithms. With the optimized subsets of features, the "curse of dimensionality" has been avoided while the accuracy of the visual model has been improved. The proposed algorithm has been tested on several publicly available datasets with various tracking challenges and benchmarked with a number of state-of-the-art approaches. The comprehensive experiments have demonstrated the efficacy of the proposed methodology.

  10. 4D tracking with ultra-fast silicon detectors

    Science.gov (United States)

    F-W Sadrozinski, Hartmut; Seiden, Abraham; Cartiglia, Nicolò

    2018-02-01

    The evolution of particle detectors has always pushed the technological limit in order to provide enabling technologies to researchers in all fields of science. One archetypal example is the evolution of silicon detectors, from a system with a few channels 30 years ago, to the tens of millions of independent pixels currently used to track charged particles in all major particle physics experiments. Nowadays, silicon detectors are ubiquitous not only in research laboratories but in almost every high-tech apparatus, from portable phones to hospitals. In this contribution, we present a new direction in the evolution of silicon detectors for charge particle tracking, namely the inclusion of very accurate timing information. This enhancement of the present silicon detector paradigm is enabled by the inclusion of controlled low gain in the detector response, therefore increasing the detector output signal sufficiently to make timing measurement possible. After providing a short overview of the advantage of this new technology, we present the necessary conditions that need to be met for both sensor and readout electronics in order to achieve 4D tracking. In the last section, we present the experimental results, demonstrating the validity of our research path.

  11. Tracking by Machine Learning Methods

    CERN Document Server

    Jofrehei, Arash

    2015-01-01

    Current track reconstructing methods start with two points and then for each layer loop through all possible hits to find proper hits to add to that track. Another idea would be to use this large number of already reconstructed events and/or simulated data and train a machine on this data to find tracks given hit pixels. Training time could be long but real time tracking is really fast Simulation might not be as realistic as real data but tacking has been done for that with 100 percent efficiency while by using real data we would probably be limited to current efficiency.

  12. Object Tracking via 2DPCA and l2-Regularization

    Directory of Open Access Journals (Sweden)

    Haijun Wang

    2016-01-01

    Full Text Available We present a fast and robust object tracking algorithm by using 2DPCA and l2-regularization in a Bayesian inference framework. Firstly, we model the challenging appearance of the tracked object using 2DPCA bases, which exploit the strength of subspace representation. Secondly, we adopt the l2-regularization to solve the proposed presentation model and remove the trivial templates from the sparse tracking method which can provide a more fast tracking performance. Finally, we present a novel likelihood function that considers the reconstruction error, which is concluded from the orthogonal left-projection matrix and the orthogonal right-projection matrix. Experimental results on several challenging image sequences demonstrate that the proposed method can achieve more favorable performance against state-of-the-art tracking algorithms.

  13. Concept of fast-track surgery and its application in perioperative period of hepatectomy for liver cancer

    Directory of Open Access Journals (Sweden)

    HAN Wei

    2016-10-01

    Full Text Available Fast-track surgery (FTS is widely used in the field of hepatopancreatobiliary surgery and has achieved a great success in the perioperative period of liver cancer. It has been recognized by clinical doctors and patients. This article introduces the concept of FTS, reviews its development, summarizes the detailed measures of FTS in the perioperative period of liver cancer and long-term application experience of FTS, and analyzes the current status of its clinical application. It is pointed out that when applied in the perioperative period of hepatectomy for liver cancer, FTS can reduce stress, lower the incidence of postoperative complications, shorten the length of hospital stay, and bring true benefits to patients.

  14. Modeling and Analysis of the Motivations of Fast Fashion Consumers in Relation to Innovativeness

    Directory of Open Access Journals (Sweden)

    Saricam Canan

    2016-12-01

    Full Text Available In this study, fast fashion concept is investigated in order to understand the motivations of the consumers that make them adopt these products because of their willingness for the innovativeness. The relationship between the motivational factors which were named as “Social or status image” and “Uniqueness” as expressions of individuality, “Conformity” and the willingness for “Innovativeness” is analyzed using a conceptual model. Exploratory factor analysis, confirmatory factor analysis and structural equation modeling were used to analyze and validate the model. The data used for the study was obtained from 244 people living in Turkey. The findings showed that the motivational factors “Social or status image” and “Uniqueness” as expressions of individuality are influential on the consumers’ willingness for “Innovativeness”.

  15. Transportation research synthesis : developing a culture of innovation.

    Science.gov (United States)

    2010-02-01

    Eight states responded to our survey. (Survey results begin on page 5 of this report.) Five of these states had initiated : efforts to facilitate innovation, four track innovative ideas, and all reward champions in some way. Standout : agencies inclu...

  16. Innovative Solar Tracking Concept by Rotating Prism Array

    Directory of Open Access Journals (Sweden)

    Héctor García

    2014-01-01

    Full Text Available Solar energy has become one of the most promising renewable energies and is the most widely used nowadays. In order to achieve an optimum performance, both photovoltaic and solar thermal applications are required to track the position of the sun throughout the day and year in the most effective way possible to avoid a high negative impact on the system efficiency. The present paper attempts to describe a novel semipassive solar tracking concentrator (SPSTC in which, in order to track the sun, two independent arrays of polymethyl methacrylate (PMMA prisms are implemented to refract sunlight by rotating said prisms, thus being able to redirect solar radiation as desired. The first set is responsible for eliminating one of the directional components of the solar radiation; the task is achieved by rotating the prisms within the array at a specific angle. The second set deals with another of the sunlight’s directional components, transforming its direction into a completely perpendicular pattern to the array. Having downward vertical radiation makes it possible to implement a stationary Fresnel lens to concentrate the solar radiation for any application desired. The system is designed and validated using simulation software to prove the feasibility of the concept.

  17. Innovation In Music

    OpenAIRE

    2014-01-01

    The music industry is a fast moving field with new technology and methodological advances combining to catalyse innovations all the time. 'Innovation in Music 2013' was an international conference exploring this topic, held in December 2013 in York, Uk. The event covered specific and cross-disciplinary aspects of the music industry including music creation, technology, production and business, sound engineering, mastering, post production and sound design, games music and cross-disciplinary t...

  18. Overview of the ATLAS Fast Tracker Project

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00025195; The ATLAS collaboration

    2016-01-01

    The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge for the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency for interesting events despite the increase in multiple collisions per bunch crossing. In order to increase the use of tracks within the High Level Trigger, the ATLAS experiment planned the installation of a hardware processor dedicated to tracking: the Fast TracKer processor. The Fast Tracker is designed to perform full scan track reconstruction of every event accepted by the ATLAS first level hardware trigger. To achieve this goal the system uses a parallel architecture, with algorithms designed to exploit the computing power of custom Associative Memory chips, and modern field programmable gate arrays. The processor will provide computing power to reconstruct tracks with transverse momentum greater than 1 GeV in the whole trackin...

  19. Object tracking on mobile devices using binary descriptors

    Science.gov (United States)

    Savakis, Andreas; Quraishi, Mohammad Faiz; Minnehan, Breton

    2015-03-01

    With the growing ubiquity of mobile devices, advanced applications are relying on computer vision techniques to provide novel experiences for users. Currently, few tracking approaches take into consideration the resource constraints on mobile devices. Designing efficient tracking algorithms and optimizing performance for mobile devices can result in better and more efficient tracking for applications, such as augmented reality. In this paper, we use binary descriptors, including Fast Retina Keypoint (FREAK), Oriented FAST and Rotated BRIEF (ORB), Binary Robust Independent Features (BRIEF), and Binary Robust Invariant Scalable Keypoints (BRISK) to obtain real time tracking performance on mobile devices. We consider both Google's Android and Apple's iOS operating systems to implement our tracking approach. The Android implementation is done using Android's Native Development Kit (NDK), which gives the performance benefits of using native code as well as access to legacy libraries. The iOS implementation was created using both the native Objective-C and the C++ programing languages. We also introduce simplified versions of the BRIEF and BRISK descriptors that improve processing speed without compromising tracking accuracy.

  20. Fast algorithm of track reconstruction for the Delphy TPC

    International Nuclear Information System (INIS)

    Maillard, J.

    1984-01-01

    We describe a simple geometrical method (polar inversion) to reconstruct tracks. When the magnetic field is constant in magnitude and direction. This method uses geometrical properties of the trajectories. In the case of the DELPHI apparatus, the track reconstruction is done using TPC informations. After explaining the algorithm, we give results on ''GEANT'' simulated events using the ''Lund'' generator. Today we get a computer time of the order of 1.2 milliseconds on a CDC 7600 and an efficiency of 98% [fr

  1. Analysis of Russian transition scenarios to innovative nuclear energy system based on thermal and fast reactors with closed nuclear fuel cycle using INPRO methodology

    International Nuclear Information System (INIS)

    Kagramanyan, V.S.; Poplavskaya, E.V.; Korobeynikov, V.V.; Kalashnikov, A.G.; Moseev, A.L.; Korobitsyn, V.E.; Andreeva-Andrievskaya, L.N.

    2011-01-01

    This paper presents the results of the analysis of modeling of Russian nuclear energy (NE) scenarios on the basis of thermal and fast reactors with closed nuclear fuel cycle (NFC). Modeling has been carried out with use of CYCLE code (SSC RF IPPE's tool) designed for analysis of Nuclear Energy System (NES) with closed NFC taking into account plutonium and minor actinides (MA) isotopic composition change during multi-recycling of fuel in fast reactors. When considering fast reactor introduction scenarios, one of important questions is to define optimal time for their introduction and related NFC's facilities. Analysis of the results obtained has been fulfilled using the key INPRO indicators for sustainable energy development. It was shown that a delay in fast reactor introduction led to serious ecological, social and finally economic risks for providing energy security and sustainable development of Russia in long-term prospects and loss of knowledge and experience in mastering innovative technologies of fast reactors and related nuclear fuel cycle. (author)

  2. The ATLAS fast tracker processor design

    CERN Document Server

    Volpi, Guido; Albicocco, Pietro; Alison, John; Ancu, Lucian Stefan; Anderson, James; Andari, Nansi; Andreani, Alessandro; Andreazza, Attilio; Annovi, Alberto; Antonelli, Mario; Asbah, Needa; Atkinson, Markus; Baines, J; Barberio, Elisabetta; Beccherle, Roberto; Beretta, Matteo; Biesuz, Nicolo Vladi; Blair, R E; Bogdan, Mircea; Boveia, Antonio; Britzger, Daniel; Bryant, Partick; Burghgrave, Blake; Calderini, Giovanni; Camplani, Alessandra; Cavaliere, Viviana; Cavasinni, Vincenzo; Chakraborty, Dhiman; Chang, Philip; Cheng, Yangyang; Citraro, Saverio; Citterio, Mauro; Crescioli, Francesco; Dawe, Noel; Dell'Orso, Mauro; Donati, Simone; Dondero, Paolo; Drake, G; Gadomski, Szymon; Gatta, Mauro; Gentsos, Christos; Giannetti, Paola; Gkaitatzis, Stamatios; Gramling, Johanna; Howarth, James William; Iizawa, Tomoya; Ilic, Nikolina; Jiang, Zihao; Kaji, Toshiaki; Kasten, Michael; Kawaguchi, Yoshimasa; Kim, Young Kee; Kimura, Naoki; Klimkovich, Tatsiana; Kolb, Mathis; Kordas, K; Krizka, Karol; Kubota, T; Lanza, Agostino; Li, Ho Ling; Liberali, Valentino; Lisovyi, Mykhailo; Liu, Lulu; Love, Jeremy; Luciano, Pierluigi; Luongo, Carmela; Magalotti, Daniel; Maznas, Ioannis; Meroni, Chiara; Mitani, Takashi; Nasimi, Hikmat; Negri, Andrea; Neroutsos, Panos; Neubauer, Mark; Nikolaidis, Spiridon; Okumura, Y; Pandini, Carlo; Petridou, Chariclia; Piendibene, Marco; Proudfoot, James; Rados, Petar Kevin; Roda, Chiara; Rossi, Enrico; Sakurai, Yuki; Sampsonidis, Dimitrios; Saxon, James; Schmitt, Stefan; Schoening, Andre; Shochet, Mel; Shoijaii, Jafar; Soltveit, Hans Kristian; Sotiropoulou, Calliope-Louisa; Stabile, Alberto; Swiatlowski, Maximilian J; Tang, Fukun; Taylor, Pierre Thor Elliot; Testa, Marianna; Tompkins, Lauren; Vercesi, V; Wang, Rui; Watari, Ryutaro; Zhang, Jianhong; Zeng, Jian Cong; Zou, Rui; Bertolucci, Federico

    2015-01-01

    The extended use of tracking information at the trigger level in the LHC is crucial for the trigger and data acquisition (TDAQ) system to fulfill its task. Precise and fast tracking is important to identify specific decay products of the Higgs boson or new phenomena, as well as to distinguish the contributions coming from the many collisions that occur at every bunch crossing. However, track reconstruction is among the most demanding tasks performed by the TDAQ computing farm; in fact, complete reconstruction at full Level-1 trigger accept rate (100 kHz) is not possible. In order to overcome this limitation, the ATLAS experiment is planning the installation of a dedicated processor, the Fast Tracker (FTK), which is aimed at achieving this goal. The FTK is a pipeline of high performance electronics, based on custom and commercial devices, which is expected to reconstruct, with high resolution, the trajectories of charged-particle tracks with a transverse momentum above 1 GeV, using the ATLAS inner tracker info...

  3. L1Track: A fast Level 1 track trigger for the ATLAS high luminosity upgrade

    International Nuclear Information System (INIS)

    Cerri, Alessandro

    2016-01-01

    With the planned high-luminosity upgrade of the LHC (HL-LHC), the ATLAS detector will see its collision rate increase by approximately a factor of 5 with respect to the current LHC operation. The earliest hardware-based ATLAS trigger stage (“Level 1”) will have to provide a higher rejection factor in a more difficult environment: a new improved Level 1 trigger architecture is under study, which includes the possibility of extracting with low latency and high accuracy tracking information in time for the decision taking process. In this context, the feasibility of potential approaches aimed at providing low-latency high-quality tracking at Level 1 is discussed. - Highlights: • HL-LH requires highly performing event selection. • ATLAS is studying the implementation of tracking at the very first trigger level. • Low latency and high-quality seem to be achievable with dedicated hardware and adequate detector readout architecture.

  4. Trends, options for market positioning and success factors in E-Mobility; Tendenzen, Positionierungsoptionen und Erfolgsfaktoren bei E-Mobilitaet. Nachhaltige Chancen fuer Elektrizitaetsversorger

    Energy Technology Data Exchange (ETDEWEB)

    Ermann, A. [The Advisory House AG, Zuerich (Switzerland); Pils, F.; Karring, K. [The Mobility House GmbH, Salzburg (Austria)

    2010-07-01

    This article discusses the trends in electro-mobility and the options available to electricity utilities when positioning themselves in this market. The factors influencing their success in doing this are also discussed. The general framework in which these activities are taking place are discussed as are the obstacles that hinder development in this area. The influence of society and politics, environmental, economical and ecological factors are looked at. Further, technological factors such as innovation and further development in the vehicle, battery and renewable energy areas are looked at. The necessary infrastructure for the operation of electrical vehicles is discussed. Case studies on electro-mobility are briefly presented and discussed. The necessary clear focus and the efficient use of the means available are stressed.

  5. Organizing and implementing a multidisciplinary fast track oncology clinic.

    Science.gov (United States)

    Basta, Y L; Tytgat, K M A J; Greuter, H H; Klinkenbijl, J H G; Fockens, P; Strikwerda, J

    2017-11-01

    Patients with gastrointestinal malignancies often need multiple appointments with different medical specialists, causing waiting times to accrue. In our hospital, care is organized in a sequential manner, causing long waiting times. To reduce this, a fast track outpatient clinic (FTC) was implemented. The FTC was organized within the hospital's existing structure. Patient centered care was achieved by ensuring that the medical specialists visit the patient, implementing nurse coordinators and considering patient wishes and co-morbidities when formulating a treatment plan. A mandate from the board (Top-down), ensured cooperation between different medical departments and a change in resource allocation (i.e. medical staff); a horizontal clinic across a vertical departmental structure. Brainstorm sessions between the departments led by two physicians who were going to work at the FTC (Bottom-up), assured a swift implementation of the FTC. Since implementation in 2009, patient influx has tripled. Waiting time for an appointment and start of treatment was reduced from 2-4 weeks to 6 working days and from 12-14 weeks to 17 working days, respectively. This was achieved by re-allocating recourses, but without increasing existing resources. The combination of a top-down and bottom-up strategy ensured participation from all involved departments, a strong foundation and a shared vision on patient centered care. The FTC facilitates sharing information between different medical specialists through both proximity and a shared electronic patient record. The implementation of the FTC comprises a change in organization, but not a change in structure. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. Automotive systems engineering

    CERN Document Server

    Winner, Hermann

    2013-01-01

    This book reflects the shift in design paradigm in automobile industry. It presents future innovations, often referred as  “automotive systems engineering”.  These cause fundamental innovations in the field of driver assistance systems and electro-mobility as well as fundamental changes in the architecture of the vehicles. New driving functionalities can only be realized if the software programs of multiple electronic control units work together correctly. This volume presents the new and innovative methods which are mandatory to master the complexity of the vehicle of the future.

  7. Fast symplectic map tracking for the CERN Large Hadron Collider

    Directory of Open Access Journals (Sweden)

    Dan T. Abell

    2003-06-01

    Full Text Available Tracking simulations remain the essential tool for evaluating how multipolar imperfections in ring magnets restrict the domain of stable phase-space motion. In the Large Hadron Collider (LHC at CERN, particles circulate at the injection energy, when multipole errors are most significant, for more than 10^{7} turns, but systematic tracking studies are limited to a small fraction of this total time—even on modern computers. A considerable speedup is expected by replacing element-by-element tracking with the use of a symplectified one-turn map. We have applied this method to the realistic LHC lattice, version 6, and report here our results for various map orders, with special emphasis on precision and speed.

  8. Physician tracking in sub-Saharan Africa: current initiatives and opportunities.

    Science.gov (United States)

    Chen, Candice; Baird, Sarah; Ssentongo, Katumba; Mehtsun, Sinit; Olapade-Olaopa, Emiola Oluwabunmi; Scott, Jim; Sewankambo, Nelson; Talib, Zohray; Ward-Peterson, Melissa; Mariam, Damen Haile; Rugarabamu, Paschalis

    2014-04-23

    Physician tracking systems are critical for health workforce planning as well as for activities to ensure quality health care - such as physician regulation, education, and emergency response. However, information on current systems for physician tracking in sub-Saharan Africa is limited. The objective of this study is to provide information on the current state of physician tracking systems in the region, highlighting emerging themes and innovative practices. This study included a review of the literature, an online search for physician licensing systems, and a document review of publicly available physician registration forms for sub-Saharan African countries. Primary data on physician tracking activities was collected as part of the Medical Education Partnership Initiative (MEPI) - through two rounds over two years of annual surveys to 13 medical schools in 12 sub-Saharan countries. Two innovations were identified during two MEPI school site visits in Uganda and Ghana. Out of twelve countries, nine had existing frameworks for physician tracking through licensing requirements. Most countries collected basic demographic information: name, address, date of birth, nationality/citizenship, and training institution. Practice information was less frequently collected. The most frequently collected practice fields were specialty/degree and current title/position. Location of employment and name and sector of current employer were less frequently collected. Many medical schools are taking steps to implement graduate tracking systems. We also highlight two innovative practices: mobile technology access to physician registries in Uganda and MDNet, a public-private partnership providing free mobile-to-mobile voice and text messages to all doctors registered with the Ghana Medical Association. While physician tracking systems vary widely between countries and a number of challenges remain, there appears to be increasing interest in developing these systems and many

  9. Dilute scintillators for large-volume tracking detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reeder, R.A. (University of New Mexico, Albuquerque, NM (United States)); Dieterle, B.D. (University of New Mexico, Albuquerque, NM (United States)); Gregory, C. (University of New Mexico, Albuquerque, NM (United States)); Schaefer, F. (University of New Mexico, Albuquerque, NM (United States)); Schum, K. (University of New Mexico, Albuquerque, NM (United States)); Strossman, W. (University of California, Riverside, CA (United States)); Smith, D. (Embry-Riddle Aeronautical Univ., Prescott, AZ (United States)); Christofek, L. (Los Alamos National Lab., NM (United States)); Johnston, K. (Los Alamos National Lab., NM (United States)); Louis, W.C. (Los Alamos National Lab., NM (United States)); Schillaci, M. (Los Alamos National Lab., NM (United States)); Volta, M. (Los Alamos National Lab., NM (United States)); White, D.H. (Los Alamos National Lab., NM (United States)); Whitehouse, D. (Los Alamos National Lab., NM (United States)); Albert, M. (University of Pennsylvania, Phi

    1993-10-01

    Dilute scintillation mixtures emit isotropic light for both fast and slow particles, but retain the Cherenkov light cone from fast particles. Large volume detectors using photomultipliers to reconstruct relativistic tracks will also be sensitive to slow particles if they are filled with these mixtures. Our data show that 0.03 g/l of b-PBD in mineral oil has a 2.4:1 ratio (in the first 12 ns) of isotropic light to Cherenkov light for positron tracks. The light attenuation length is greater than 15 m for wavelength above 400 nm, and the scintillation decay time is about 2 ns for the fast component. There is also a slow isotropic light component that is larger (relative to the fast component) for protons than for electrons. This effect allows particle identification by a technique similar to pulse shape discrimination. These features will be utilized in LSND, a neutrino detector at LAMPF. (orig.)

  10. Tracking uptake of innovations from the European Union Public Health Programme.

    Science.gov (United States)

    Voss, Margaretha; Alexanderson, Kristina; McCarthy, Mark

    2013-11-01

    The European Commission developed the Public Health Programme to enable cross-national innovation and transfer in fields of health information, health threats and health promotion. PHIRE (Public Health Innovation and Research in Europe), a collaboration of the European Public Health Association (EUPHA) with seven partners, addressed the uptake of these public health innovation projects at country level. EUPHA thematic sections lead on areas of public health practice and research and experts can choose to be section members. The section presidents of seven sections chose eight European public health projects, starting in the EU Public Health Programme in 2003-05, that provided new knowledge for practice and covered a majority of the EU countries. A web-based questionnaire recorded country informants' (CIs) perceptions of uptake, assessed as relevance and dissemination to a range of public and non-governmental organizations. 108 CIs individually described the eight innovations in an average of 14 (46%) of the 30 European countries. Three of the eight innovations were considered of high relevance by >60% of respondents and at least 70% of informants considered seven of the eight innovation projects as of high or moderate relevance. Dissemination was noted across governmental, professional and academic settings, with high impact on knowledge/awareness for at least 30% of CIs. Some projects had uptake within the policy cycle in particular countries and connected strongly with academics and professionals. Projects working at local level had less visibility nationally and some projects were unknown to national respondents. European Union funding for public health can contribute to cross-national knowledge transfer and uptake of innovations. More attention is needed to classify, characterize and identify public health innovations and to demonstrate their direct contribution to European health and well-being.

  11. The Fast Tracker Real Time Processor: high quality real-time tracking at ATLAS

    CERN Document Server

    Stabile, A; The ATLAS collaboration

    2011-01-01

    As the LHC luminosity is ramped up to the design level of 1x1034 cm−2 s−1 and beyond, the high rates, multiplicities, and energies of particles seen by the detectors will pose a unique challenge. Only a tiny fraction of the produced collisions can be stored on tape and immense real-time data reduction is needed. An effective trigger system must maintain high trigger efficiencies for the most important physics and at the same time suppress the enormous QCD backgrounds. This requires massive computing power to minimize the online execution time of complex algorithms. A multi-level trigger is an effective solution for an otherwise impossible problem. The Fast Tracker (FTK)[1], [2] is a proposed upgrade to the current ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK is a dedicated Super Computer based on a mixture of advanced technologies. The architecture broadly employs powerf...

  12. GPS Navigation and Tracking Device

    Directory of Open Access Journals (Sweden)

    Yahya Salameh Khraisat

    2011-10-01

    Full Text Available Since the introduction of GPS Navigation systems in the marketplace, consumers and businesses have been coming up with innovative ways to use the technology in their everyday life. GPS Navigation and Tracking systems keep us from getting lost when we are in strange locations, they monitor children when they are away from home, keep track of business vehicles and can even let us know where a philandering partner is at all times. Because of this we attend to build a GPS tracking device to solve the mentioned problems. Our work consists of the GPS module that collects data from satellites and calculates the position information before transmitting them to the user’s PC (of Navigation system or observers (of Tracking System using wireless technology (GSM.

  13. The impact of a fast track area on quality and effectiveness outcomes: a Middle Eastern emergency department perspective.

    LENUS (Irish Health Repository)

    Devkaran, Subashnie

    2009-01-01

    BACKGROUND: Emergency department (ED) overcrowding is a ubiquitous problem with serious public health implications. The fast track area is a novel method which aims to reduce waiting time, patient dissatisfaction and morbidity. |The study objective was to determine the impact of a fast track area (FTA) on both effectiveness measures (i.e. waiting times [WT] and length of stay [LOS]) and quality measures (i.e. LWBS rates and mortality rates) in non-urgent patients. The secondary objective was to assess if a FTA negatively impacted on urgent patients entering the ED. METHODS: The study took place in a 500 bed, urban, tertiary care hospital in Abu Dhabi, United Arab Emirates. This was a quasi-experimental, which examined the impact of a FTA on a pre-intervention control group (January 2005) (n = 4,779) versus a post-intervention study group (January 2006) (n = 5,706). RESULTS: Mean WTs of Canadian Triage Acuity Scale (CTAS) 4 patients decreased by 22 min (95% CI 21 min to 24 min, P < 0.001). Similarly, mean WTs of CTAS 5 patients decreased by 28 min (95% CI 19 min to 37 min, P < 0.001) post FTA. The mean WTs of urgent patients (CTAS 2\\/3) were also significantly reduced after the FTA was opened (P < 0.001). The LWBS rate was reduced from 4.7% to 0.7% (95% CI 3.37 to 4.64; P < 0.001). Opening a FTA had no significant impact on mortality rates (P = 0.88). CONCLUSION: The FTA improved ED effectiveness (WTs and LOS) and quality measures (LWBS rates) whereas mortality rate remained unchanged.

  14. Overview of the ATLAS Fast Tracker Project

    CERN Document Server

    Ancu, Lucian Stefan; The ATLAS collaboration

    2016-01-01

    The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge for the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency for interesting events despite the increase in multiple collisions per bunch crossing. In order to increase the use of tracks within the High Level Trigger, the ATLAS experiment planned the installation of a hardware processor dedicated to tracking: the Fast TracKer processor. The Fast Tracker is designed to perform full scan track reconstruction of every event accepted by the ATLAS first level hardware trigger. To achieve this goal the system uses a parallel architecture, with algorithms designed to exploit the computing power of custom Associative Memory chips, and modern field programmable gate arrays. The processor will provide computing power to reconstruct tracks with transverse momentum greater than 1 GeV in the whol...

  15. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  16. Underwater Acoustic Target Tracking: A Review

    Science.gov (United States)

    Han, Ying; Fan, Liying

    2018-01-01

    Advances in acoustic technology and instrumentation now make it possible to explore marine resources. As a significant component of ocean exploration, underwater acoustic target tracking has aroused wide attention both in military and civil fields. Due to the complexity of the marine environment, numerous techniques have been proposed to obtain better tracking performance. In this paper, we survey over 100 papers ranging from innovative papers to the state-of-the-art in this field to present underwater tracking technologies. Not only the related knowledge of acoustic tracking instrument and tracking progress is clarified in detail, but also a novel taxonomy method is proposed. In this paper, algorithms for underwater acoustic target tracking are classified based on the methods used as: (1) instrument-assisted methods; (2) mode-based methods; (3) tracking optimization methods. These algorithms are compared and analyzed in the aspect of dimensions, numbers, and maneuvering of the tracking target, which is different from other survey papers. Meanwhile, challenges, countermeasures, and lessons learned are illustrated in this paper. PMID:29301318

  17. Nuclear Track-Etched Pore Membrane Production Using OAEP's Research Reactor

    International Nuclear Information System (INIS)

    Chittrakarn, Thawat; Bhongsuwan, Tripob; Wanichapichart, Pikul; Nuanuin, Paiboon; Chongkum, Somporn; Khonduangkaew, Areerat; Bordeepong, Sunaree

    2003-10-01

    Result of this study shows that the OAEP's nuclear research reactor is a good source of both fast and thermal neutrons for pore piercing process on polycarbonate thin film. With our experimental design, the fast neutron provides better results in pore piercing comparing with thermal neutron bombardment. This can be explained that most of the latent tracks that occur by thermal neutron bombardment do not piercing through the thin film. Chemical etching process using NaOH solution with an appropriated time, concentration and temperature was employed to enlarge the latent tracks in the bombarded film by fast neutrons. Fast neutron bombardment with 5, 10 and 20 minutes bombarding time successfully produces the nuclear track membrane. Pore size and pore density of the produced membranes examined by SEM were 0.24-1.01 μm and 4.67 - 245 x 10 6 pore/cm 2 , respectively. Bubble point test showed the maximum pore diameter of the produced membrane ranged between 1.18 - 3.25 μm. Water permeability was studied and compared between the produced and commercial membranes

  18. Fast tracking detector with fiber scintillators and a position sensitive photomultiplier

    International Nuclear Information System (INIS)

    Salomon, M.; Li, V.; Smith, G.; Wu, Y.S.

    1988-11-01

    We have studied the properties of a tracking detector composed of 32 fiber scintillators coupled to a multianode photomultiplier placed in a pion beam at TRIUMF. We measured the efficiency of the detector, as well as its tracking capabilities and double hit resolution

  19. FATRAS - the ATLAS Fast Track Simulation project

    NARCIS (Netherlands)

    Mechnich, J.

    2011-01-01

    The Monte Carlo simulation of the detector response is an integral component of any analysis performed with data from the LHC experiments. As these simulated data sets must be both large and precise, their production is a CPU-intensive task. ATLAS has developed full and fast detector simulation

  20. Creating safer coastal and port infrastructure with innovative physical and numerical modelling

    CSIR Research Space (South Africa)

    Tulsi, K

    2015-10-01

    Full Text Available Infrastructure with Innovative Physical and Numerical Modelling Kishan Tulsi  Physical and Numerical modelling  Breakwater Monitoring  Armour track  Vessel manoeuvring simulations for safe port design and operations  Simflex software... – Integrated Port Operations Support System  Virtual Buoy Physical modelling Numerical modelling Armour Track Armour Track Armour Track Armour Track Armour track using 3D data points Ship manoeuvring simulations: Ship Manoeuvring simulations Port...

  1. Diagnostic methods for fast-track identification of endometrial cancer in women with postmenopausal bleeding and endometrial thickness greater than 5 mm

    DEFF Research Database (Denmark)

    Dueholm, Margit; Marinowskij, Edvard; Hansen, Estrid Stæhr

    2015-01-01

    efficiency (area under the curve) for malignancy diagnosis (ES, 0.90; TVS, 0.88; GIS, 0.92; HYpattern, 0.91). When insufficient samples were incorporated, ES was less efficient than the other techniques. ES was not more efficient in the subgroup of women without localized lesions than in the subgroup...... of women with localized lesions. MRI and HYpattern added limited efficiency, whereas hysteroscopy with biopsy was most efficient. CONCLUSIONS: As a first-line technique, pattern recognition on TVS, GIS, and HYpattern correctly identifies 9 of 10 women with malignancy and is superior to pattern recognition...... on ES when insufficient samples are included. Endometrial pattern evaluated with TVS and GIS is a fast and efficient first-line diagnostic tool that outperforms ES in women with or without localized lesions. Malignant patterns on TVS/GIS should warrant fast-track evaluation, whereas women with benign...

  2. Multiphase Interface Tracking with Fast Semi-Lagrangian Contouring.

    Science.gov (United States)

    Li, Xiaosheng; He, Xiaowei; Liu, Xuehui; Zhang, Jian J; Liu, Baoquan; Wu, Enhua

    2016-08-01

    We propose a semi-Lagrangian method for multiphase interface tracking. In contrast to previous methods, our method maintains an explicit polygonal mesh, which is reconstructed from an unsigned distance function and an indicator function, to track the interface of arbitrary number of phases. The surface mesh is reconstructed at each step using an efficient multiphase polygonization procedure with precomputed stencils while the distance and indicator function are updated with an accurate semi-Lagrangian path tracing from the meshes of the last step. Furthermore, we provide an adaptive data structure, multiphase distance tree, to accelerate the updating of both the distance function and the indicator function. In addition, the adaptive structure also enables us to contour the distance tree accurately with simple bisection techniques. The major advantage of our method is that it can easily handle topological changes without ambiguities and preserve both the sharp features and the volume well. We will evaluate its efficiency, accuracy and robustness in the results part with several examples.

  3. Innovative Practices for Special Warfare

    Science.gov (United States)

    2015-12-01

    stealing customers from traditional quick service fast food restaurants .243 Innovations in restaurant design, food preparation and distribution, are...and diverse organizations to reap the benefits of loyalty and connectivity that small teams enjoy.152 To create the linkages, JSOC strove to dissolve...those new to a field. Garage startups generate many disruptive innovations because “they are not tied to any specific customer base, product design

  4. Effects of R&D Cooperation to Innovation Performance in Open Innovation Environment

    Directory of Open Access Journals (Sweden)

    Gao Liang

    2014-05-01

    Full Text Available Dynamic nonlinear characteristics of internal and external environment in modern organization shows up increasingly, which make innovative research breakthrough organizational boundaries and present a pattern of open mode, the traditional mode of innovation is facing huge challenges like increasing innovation cycle, huge R&D input and inefficient knowledge transfer. And cooperation with external organizations to implement R&D is definitely a possibility to solve the open innovation environment challenge. Since organizations often have multiple dimensions of cooperation with different types of organization for research and development for the influence of organizational innovation performance or for exploring cooperation at the same time in different areas, and in different types of institutions. This paper studied the innovation performance of relevant government agencies except such innovation organization as enterprises, universities, and research institutions for the first time. This paper tracked on a survey of China's national engineering technology research center in related situation from 2002 to 2011 and collected related data to research and development cooperation and innovation performance for empirical research. Study found that universities have advantages in richness, in knowledge itself and knowledge accessible extent, cooperation with university in R&D is the best choice to promote the innovation performance of the organization. While cooperating with domestic universities and domestic enterprises to carry out research and development has bad effect in organizational innovation performance; while cooperation with domestic institutions and foreign institutions in the research and development plays a positive role in promoting innovation.

  5. Options Study Documenting the Fast Reactor Fuels Innovative Design Activity

    Energy Technology Data Exchange (ETDEWEB)

    Jon Carmack; Kemal Pasamehmetoglu

    2010-07-01

    This document provides presentation and general analysis of innovative design concepts submitted to the FCRD Advanced Fuels Campaign by nine national laboratory teams as part of the Innovative Transmutation Fuels Concepts Call for Proposals issued on October 15, 2009 (Appendix A). Twenty one whitepapers were received and evaluated by an independent technical review committee.

  6. Energy dependence of fast neutron dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Su, S.J.; Morgan, K.Z.

    1978-01-01

    Registration of fast-neutron induced recoil tracks by the electrochemical etching technique as applied to sensitive Lexan polycarbonate foils provides a simple and inexpensive means of fast neutron personnel dosimetry. The sensitivity (tracks/neutron) of recoil particle registration is given as a function of neutron energy. Neutrons of 7 Li (p,n) 7 Be, 3 T (d,n) 4 He and 9 B, respectively. Results are compared with other studies using other neutron sources and conventional etching method

  7. Analysis of the use of obfusctated web tracking

    OpenAIRE

    Fallace, Federico

    2017-01-01

    In the last years, web tracking has became a fast-growing phenomenon. Pro- filing users to provide targeted advertisement is a business that counts hundreds of companies and billions of dollars. On the other hand, communities, researchers and other companies are building countermeasures to prevent tracking practices, so the techniques are becoming more sophisticated and hidden. This work has the goal of uncovering the obfuscation that is becoming common in web tracking metho...

  8. Nanometer-scale anatomy of entire Stardust tracks

    Science.gov (United States)

    Nakamura-Messenger, Keiko; Keller, Lindsay P.; Clemett, Simon J.; Messenger, Scott; Ito, Motoo

    2011-07-01

    We have developed new sample preparation and analytical techniques tailored for entire aerogel tracks of Wild 2 sample analyses both on "carrot" and "bulbous" tracks. We have successfully ultramicrotomed an entire track along its axis while preserving its original shape. This innovation allowed us to examine the distribution of fragments along the entire track from the entrance hole all the way to the terminal particle. The crystalline silicates we measured have Mg-rich compositions and O isotopic compositions in the range of meteoritic materials, implying that they originated in the inner solar system. The terminal particle of the carrot track is a 16O-rich forsteritic grain that may have formed in a similar environment as Ca-, Al-rich inclusions and amoeboid olivine aggregates in primitive carbonaceous chondrites. The track also contains submicron-sized diamond grains likely formed in the solar system. Complex aromatic hydrocarbons distributed along aerogel tracks and in terminal particles. These organics are likely cometary but affected by shock heating.

  9. Single-photon sensitive fast ebCMOS camera system for multiple-target tracking of single fluorophores: application to nano-biophotonics

    Science.gov (United States)

    Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi

    2011-03-01

    Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.

  10. Experience with "Fast track" postoperative care after deep brain stimulation surgery.

    Science.gov (United States)

    Martín, Nuria; Valero, Ricard; Hurtado, Paola; Gracia, Isabel; Fernández, Carla; Rumià, Jordi; Valldeoriola, Francesc; Carrero, Enrique J; Tercero, Francisco Javier; de Riva, Nicolás; Fàbregas, Neus

    A 24-h-stay in the post-anesthesia care unit (PACU) is a common postoperative procedure after deep brain stimulation surgery (DBS). We evaluated the impact of a fast-track (FT) postoperative care protocol. An analysis was performed on all patients who underwent DBS in 2 periods: 2006, overnight monitored care (OMC group), and 2007-2013, FT care (FT group). The study included 19 patients in OMC and 95 patients in FT. Intraoperative complications occurred in 26.3% patients in OMC vs. 35.8% in FT. Post-operatively, one patient in OMC developed hemiparesis, and agitation in 2 patients. In FT, two patients with intraoperative hemiparesis were transferred to the ICU. While on the ward, 3 patients from the FT developed hemiparesis, two of them 48h after the procedure. Thirty eight percent of FT had an MRI scan, while the remaining 62% and all patients of OMC had a CT-scan performed on their transfer to the ward. One patient in OMC had a subthalamic hematoma. Two patients in FT had a pallidal hematoma, and 3 a bleeding along the electrode. A FT discharge protocol is a safe postoperative care after DBS. There are a small percentage of complications after DBS, which mainly occur within the first 6h. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Application of fast track surgery in elderly patients during perioperative period of laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    ZHANG Yong

    2014-12-01

    Full Text Available ObjectiveTo investigate the safety and superiority of fast track surgery (FTS in elderly patients during the perioperative period of laparoscopic cholecystectomy (LC. MethodsThe clinical data of 124 elderly patients who underwent LC at the Department of General Surgery in our institution between January 2010 and March 2014 were assessed, with 62 cases assigned to FTS group and 62 cases to conventional method group. Anal exhaust time, feeding time, off-bed activity time, and length of hospital stay were compared between the two groups, and postoperative results and adverse reactions were recorded. Continuous data were analyzed using the independent-samples t test, and categorical data were compared using the chi-square test. Results Compared with the control method group, patients in the FTS group showed earlier postoperative anal exhaust, feeding, and off-bed activity, a shorter length of hospital stay, and a lower incidence of postoperative cardiovascular and cerebrovascular complications (P<0.05. ConclusionFTS is an effective approach to accelerate rehabilitation in elderly patients after LC.

  12. Prototypdetektoren für das geplante Upgradeprojekt 'Muon Track Fast Tag' am CMS-Experiment

    CERN Document Server

    Weingarten, Simon; Stahl, Achim

    Upgrading the muon system will be one of the major challenges for the CMS experiment atthe projected high luminosity LHC (HL-LHC) with an expected instantaneous luminosityof L = 1035 /(cm2 · s). Most importantly, the muon trigger rate has to be reduced inorder to keep the level 1 trigger rate inside the reserved bandwidth. Another concernthat has to be dealt with is the rising number of ambiguities in the muon chambers dueto simultaneously traversing muons, so-called ghost hits. With the Muon Track fast Tag(MTT), a new detector subsystem between the CMS solenoid and the first muon stationis proposed to solve these problems. An implementation of the MTT system based on fastplastic scintillators read out by silicon photomultipliers (SiPM) is under development atthe Physics Institute III of RWTH Aachen University.In this thesis, results of prototype detectors with 100 × 100 × 5 mm3 scintillator-tilesand dual SiPM-readout are presented. All studies have been done with cosmic muons andfocus on parameter optimi...

  13. A C++ object-oriented toolkit for track finding with k-dimensional hits

    International Nuclear Information System (INIS)

    Uiterwijk, J.W.E.; Panman, J.; Vyver, B. van de

    2006-01-01

    A library is described for the recognition of tracks in a set of hits. The hits are assumed to be k-dimensional points (k-d), with k>=1, of which a subset can be grouped into tracks by using short-range correlations. A connection graph between the hits is created by sorting the hits first in k-d space using one of the developed, fast, k-space containers. The track-finding algorithm considers any connection between two hits as a possible track seed and grows these seeds into longer track segments using a modified depth-first search of the connection graph. All hit-acceptance decisions are called via abstract methods of an acceptance criterion class which isolates the library from the application's hit and track model. An application is tuned for a particular tracking environment by creating a concrete implementation for the hit and track acceptance calculations. The implementer is free to trade tracking time for acceptance complexity (influencing efficiency) depending on the requirements of the particular application. Results for simulated data show that the track finding is both efficient and fast even for high noise environments

  14. Measurement of accelerator-based neutron distributions using nuclear track detectors

    International Nuclear Information System (INIS)

    Al-Jarallah, M.I.; Abu-Jarad, F.; Rehman, Fazal-ur-; Khiari, F.Z.; Aksoy, A.; Nassar, R.

    2000-01-01

    Nuclear track detectors were used to measure the longitudinal and transverse distributions of slow neutrons in a moderated neutron field as well as the longitudinal and transverse distributions of fast neutrons produced on the 0 deg. beam line of the KFUPM 350 keV ion accelerator. The neutrons were first produced from the T(d,n) 4 He reaction with a neutron energy of approximately 14 MeV and were then moderated in a cylindrical polyethylene moderator placed at the end of the 0 deg. beam line. The optimal transverse slow neutron distribution was found to be uniform within ±4.5% at a 3 cm depth inside the moderator. The fast neutron distribution component along the moderator central axis exhibited an exponential-like drop in intensity with depth. Linearity checks of alpha and proton recoil track density with irradiation time for the nuclear track detectors were verified for both slow and fast neutrons

  15. Measurement of accelerator-based neutron distributions using nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Abu-Jarad, F.; Rehman, Fazal-ur-; Khiari, F.Z.; Aksoy, A.; Nassar, R

    2000-12-01

    Nuclear track detectors were used to measure the longitudinal and transverse distributions of slow neutrons in a moderated neutron field as well as the longitudinal and transverse distributions of fast neutrons produced on the 0 deg. beam line of the KFUPM 350 keV ion accelerator. The neutrons were first produced from the T(d,n){sup 4}He reaction with a neutron energy of approximately 14 MeV and were then moderated in a cylindrical polyethylene moderator placed at the end of the 0 deg. beam line. The optimal transverse slow neutron distribution was found to be uniform within {+-}4.5% at a 3 cm depth inside the moderator. The fast neutron distribution component along the moderator central axis exhibited an exponential-like drop in intensity with depth. Linearity checks of alpha and proton recoil track density with irradiation time for the nuclear track detectors were verified for both slow and fast neutrons.

  16. Service innovation in China

    DEFF Research Database (Denmark)

    Slepniov, Dmitrij; Jin, Jun

    2014-01-01

    Purpose – The aim of this paper is to advance our understanding of service innovation in China and to identify the major drivers and impediments for manufacturing companies pushing into services in China. Design/methodology/approach – By employing an in-depth longitudinal case of a Chinese company...... Chinese cities. Both internal and external factors played a significant role in influencing the development and implementation of service innovation in the case. The paper details and discusses the factors that affect service innovation in China. Research Limitations – The study is exposed...... in informing our expectations about the push of many Chinese manufacturing companies into services. The paper provides insights into the development and diffusion of service innovation in many fast transforming industrial companies in China. Lessons for other developing countries can also be drawn from...

  17. Incidence of and risk factors for postoperative urinary retention in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars; Bogø, Stina; Raaschou, Sofie

    2015-01-01

    BACKGROUND AND PURPOSE: Postoperative urinary retention (POUR) is a clinical challenge, but there is no scientific evidence for treatment principles. We describe the incidence of and predictive factors for POUR in fast-track total hip (THA) and knee arthroplasty (TKA). PATIENTS AND METHODS......, and preoperative international prostate symptom score (IPSS) were compared between catheterized and non-catheterized patients. RESULTS: The incidence of POUR was 40% (range between departments: 30-55%). Median bladder volume evacuated by catheterization was 0.6 (0.1-1.9) L. Spinal anesthesia increased the risk...... was 40%, with spinal anesthesia and increased IPSS in males as predictive factors. The large variation in perioperative bladder management and in bladder volumes evacuated by catheterization calls for randomized studies to define evidence-based principles for treatment of POUR in the future....

  18. Why, when, and how fast innovations are adopted

    Science.gov (United States)

    Gonçalves, S.; Laguna, M. F.; Iglesias, J. R.

    2012-06-01

    When the full stock of a new product is quickly sold in a few days or weeks, one has the impression that new technologies develop and conquer the market in a very easy way. This may be true for some new technologies, for example the cell phone, but not for others, like the blue-ray. Novelty, usefulness, advertising, price, and fashion are the driving forces behind the adoption of a new product. But, what are the key factors that lead to adopt a new technology? In this paper we propose and investigate a simple model for the adoption of an innovation which depends mainly on three elements: the appeal of the novelty, the inertia or resistance to adopt it, and the interaction with other agents. Social interactions are taken into account in two ways: by imitation and by differentiation, i.e., some agents will be inclined to adopt an innovation if many people do the same, but other will act in the opposite direction, trying to differentiate from the "herd". We determine the conditions for a successful implantation of the new technology, by considering the strength of advertising and the effect of social interactions. We find a balance between the advertising and the number of anti-herding agents that may block the adoption of a new product. We also compare the effect of social interactions, when agents take into account the behavior of the whole society or just a part of it. In a nutshell, the present model reproduces qualitatively the available data on adoption of innovation.

  19. Chemical etching studies of a Brazilian polycarbonate to fast neutron detection

    International Nuclear Information System (INIS)

    Souto, E.B.; Campos, L.L.

    2006-01-01

    The Dosimetric Materials Laboratory (LMD) of the Radiation Metrology Center (CMR) is developing a personal dosimeter for fast neutrons using the technique of solid state nuclear track detectors (SSNTD). This technique is based on the recorded damage (tracks) in dielectric materials due to the impact of charged particles. The tracks are revealed and amplified for visualization in optic microscope through a technique known as chemical etching. The LMD is investigating a Brazilian commercial polycarbonate as a new passive fast neutron's detector in substitution to the traditional materials, as the cellulose nitrate LR-115 and the polycarbonates Makrofol and CR-39. The variation of the etching parameters (chemical solution, time and temperature) alters the response of the material; the best revelation conditions provide the best relationship among the amount of revealed tracks, their clearness and the time spent for this. The polycarbonate studied is a resin of same chemical monomer of Makrofol (C,6H,403). Samples of 3 x 1 cm 2 of the polycarbonate were irradiated with 5 mSv of fast neutrons ( 241 Am-Be) and revealed with the chemical solution PEW-40 (15% KOH, 45% H 2 O, 40% C 2 H 5 OH), commonly used for Makrofol. The studied etching parameters were time and temperature. Groups of four samples were revealed at temperatures of 50, 65, 75, 90 and 100 C with etching times varying from one to six hours. The used track's counting procedure was that referred in the literature. The best response to fast neutrons was obtained at 75 C; in spite of their similar answers, smaller temperatures join larger uncertainties in the track's counting and poorer clearness. At this temperature, the number of revealed tracks increases with the etching time approximately until a plateau at three hours. For etching times higher than four hours the polycarbonate presents overlap of tracks. If the temperature is adjusted to 75 C, the etching time should be in the plateau to avoid that small

  20. Scalable Track Detection in SAR CCD Images

    Energy Technology Data Exchange (ETDEWEB)

    Chow, James G [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Quach, Tu-Thach [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images ta ken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are often too simple to capture natural track features such as continuity and parallelism. We present a simple convolutional network architecture consisting of a series of 3-by-3 convolutions to detect tracks. The network is trained end-to-end to learn natural track features entirely from data. The network is computationally efficient and improves the F-score on a standard dataset to 0.988, up fr om 0.907 obtained by the current state-of-the-art method.

  1. A fast and flexible reactor physics model for simulating neutron spectra and depletion in fast reactors - 202

    International Nuclear Information System (INIS)

    Recktenwald, G.D.; Bronk, L.A.; Deinert, M.R.

    2010-01-01

    Determining the time dependent concentration of isotopes within a nuclear reactor core is central to the analysis of nuclear fuel cycles. We present a fast, flexible tool for determining the time dependent neutron spectrum within fast reactors. The code (VBUDS: visualization, burnup, depletion and spectra) uses a two region, multigroup collision probability model to simulate the energy dependent neutron flux and tracks the buildup and burnout of 24 actinides, as well as fission products. While originally developed for LWR simulations, the model is shown to produce fast reactor spectra that show high degree of fidelity to available fast reactor benchmarks. (authors)

  2. Characterization of plastic nuclear track detectors on solid state, CR-39 and LR-115 and its possibilities application on thermal and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Vallejo Delgado, L.R.

    1989-01-01

    This work is an study about the use feasibility of plastic nuclear track detectors, LR 115, II-B (of Eastmann Kodak Co) and CR-39 (of American Acrylics and Plastics), for thermal and fast neutron dosimetry, respectively. The LR-115 with converter (n, alpha) was exposed to thermal neutrons with energy of 0,046 e V, proceeding from nuclear reactor RECH-1 of Nuclear Energy Chilean Commission. The irradiated films were submited to a chemical etching with NaOH, plus a washing and brushing. The CR-39 with polyethylene irradiator, was exposed to fast neutrons proceeding of calibrated sources of Am-Se. The irradiated plates were submited to a chemical pre-etching with KOH and a electrochemical post-etching. (author)

  3. The FastTrack Real Time Processor and Its Impact on Muon Isolation, Tau and b-Jet Online Selections at ATLAS

    CERN Document Server

    Crescioli, F; The ATLAS collaboration; Zhang, J; Boveia, A; Bevacqua, V; Cheng, Y; Canelli, F; Bogdan, M; Dell'Orso, M; Bossini, E; Citterio, M; Dunford, M; Drake, G; Beretta, M; Genat, JF; Annovi, A; Kim, YK; Kimura, N; Andreazza, A; Kapliy, A; Kasten, M; Piendibene, M; Negri, A; Meroni, C; Giannetti, P; Melachrinos, C; Hoff, J; Liberali, V; McCarn, A; Neubauer, M; Tang, F; Shochet, M; Stabile, A; Sartori, L; Sabatini, F; Proudfoot, J; Riva, M; Liu, T; Punzi, G; Vercesi, V; Tuggle, J; Todri, A; Tripiccione, R; Lanza, A; Wu, J; Yorita, K; Volpi, G; Vitullo, R.A; Sacco, I

    2010-01-01

    As the LHC luminosity is ramped up to 31034 cm−2 s−1 and beyond, the high rates, multiplicities, and energies of particles seen by the detectors will pose a unique challenge. Only a tiny fraction of the produced collisions can be stored on tape and immense real-time data reduction is needed. An effective trigger system must maintain high trigger efficiencies for the physics we are most interested in, and at the same time suppress the enormous QCD backgrounds. This requires massive computing power to minimize the online execution time of complex algorithms. A multi-level trigger is an effective solution for an otherwise impossible problem. The Fast Tracker (FTK) is a proposed upgrade to the current ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK solves the combinatorial challenge inherent to tracking by exploiting massive parallelism of associative memories that can compa...

  4. LHCb: The LHCb tracking concept and performance

    CERN Multimedia

    Rodrigues, E

    2009-01-01

    The LHCb tracking system is designed to reconstruct charged particle trajectories in the forward spectrometer, in view of high precision studies of CP-violating phenomena and searches for rare b-hadron decays at the LHC. The system is composed of four major subdetectors and a dedicated magnet, providing an excellent momentum resolution just above 0.4%. The tracking model is based on the innovative trajectories concept introduced by the BaBar collaboration to reconstruct and fit the tracks, and has been further developed and improved. It is now able to cope with realistic geometries and misalignments in a sophisticated, robust and detector-independent way. The LHCb tracking concept including the interplay of various complementary pattern recognition algorithms and the bi-directional Kalman fitter will be described. The current performance of the tracking, based on the latest simulations, will be presented. Recent results obtained with the first LHC beam tracks from injection tests will be discussed.

  5. How innovative New Zealand firms procure environmental innovations for the construction industry : a literature review

    NARCIS (Netherlands)

    Staal, Anne; Tookey, John; Seadon, Jeff; Walhof, Gert; Mobach, Mark P.

    2015-01-01

    Construction industries in New Zealand and abroad have a low track record for successful sustainable innovations. This often has a negative impact on private and government spending, and on quality, society and the environment. This paper posits that the construction industry needs step-change (i.e.

  6. The Systems Approach to Innovation Studies

    Directory of Open Access Journals (Sweden)

    Karen Manley

    2002-05-01

    Full Text Available The academic literature, and business practice, reveals a shift in the way analysts understand innovation processes. This shift is not revealed as a cohesive trend, rather it comprises contributions from a wide range of academic disciplines and empirical evidence. Building on Edquist (1997 this paper ties together the diverse new ideas which stress a systems approach to successful innovation. The paper presents an up-to-date overview of this fast moving field, with a view to assisting public policy makers and business managers in designing more effective innovation processes.

  7. Developing technology intelligence strategy to access knowledge of innovation clusters.

    OpenAIRE

    Rani Jeanne Dang; Letizia Mortara; Ruth Thomson; Tim Minshall

    2010-01-01

    Current times are characterised by a knowledge-based economy and fast technological change. In this difficult environment, companies compete to maintain a relevant position through innovation. In response to these challenges, many companies are currently adopting an open approach to innovation, pursuing innovation by combining internal and external resources. Technology intelligence (TI) activities support the implementation of open innovation with the systematic capture and delivery of infor...

  8. Using track detectors in neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The usage of track detectors of charged particles provides a new possibility of neutron dosimetry. Presented is a comparison of the main dosimetric characteristics of three various types of track detectots of fast neutrons, i.e. glass in the contact with 232 Th; KODAK LR115 cellulose nitrate; MAKROFOL E polycarbonate. Results of studing energy dependences of detectors are presented. Results obtained using phantoms under radiation fields of various sources of complex gamma-neutron radiation are discussed [ru

  9. EMC design for actuators in the FAST reflector

    Science.gov (United States)

    Zhang, Hai-Yan; Wu, Ming-Chang; Yue, You-Ling; Gan, Heng-Qian; Hu, Hao; Huang, Shi-Jie

    2018-04-01

    An active reflector is one of the three main innovations incorporated in the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The deformation of such a huge spherically shaped reflector into different transient parabolic shapes is achieved by using 2225 hydraulic actuators which change the position of the 2225 nodes through the connected down tied cables. For each different tracking process of the telescope, more than 1/3 of these 2225 actuators must be in operation to tune the parabolic aperture accurately and meet the surface error restriction. This means that some of these actuators are inevitably located within the main beam of the receiver, and Electromagnetic Interference (EMI) from the actuators must be mitigated to ensure the scientific output of the telescope. Based on the threshold level of interference detrimental to radio astronomy described in ITU-R Recommendation RA.769 and EMI measurements, the shielding efficiency (SE) requirement for each actuator is set to be 80 dB in the frequency range from 70 MHz to 3 GHz. Therefore, Electromagnetic Compatibility (EMC) was taken into account in the actuator design by measures such as power line filters, optical fibers, shielding enclosures and other structural measures. In 2015, all the actuators had been installed at the FAST site. Till now, no apparent EMI from the actuators has been detected by the receiver, which demonstrates the effectiveness of these EMC measures.

  10. Unveiling scientific communities about sustainability and innovation. A bibliometric journey around sustainable terms

    DEFF Research Database (Denmark)

    Franceschini, Simone; Faria, Lourenco; Jurowetzki, Roman

    2016-01-01

    innovation), and they concluded that such terms are mostly interchangeable. These findings surprise in light of the different positions shown in the innovation for sustainability debate. Our bibliometric analysis tracks meanings and communities associated with these four terms and indicates some overlaps......, especially between eco-innovation and environmental innovation. However, we found relevant differences of meanings and communities that reflect the different positions in the innovation for sustainability debate....

  11. Managing postharvest innovation: a review of developments and trends

    NARCIS (Netherlands)

    Batterink, M.H.; Omta, S.W.F.; Wubben, E.F.M.

    2005-01-01

    Purpose of the review: With the fast developments in technologies, combined with increased global competition and changing customer demands, innovation is increasingly seen as a means for sustainable growth. This paper reviews literature on the management of innovation and the most prominent

  12. Electric vehicles need biofuels; Elektroautos brauchen Biotreibstoffe

    Energy Technology Data Exchange (ETDEWEB)

    Engel, Tomi

    2008-09-15

    The debate over electromobility is in full swing. The effects on the electric power grid and on the biofuels industry are quire different than expected, even paradox. (orig.) [German] Die Debatte um Elektromobilitaet ist in vollem Gang. Die Auswirkung auf das Stromnetz und auf die Biotreibstoffbranche sind ganz anders, als man denkt. Sie wirken fast schon paradox. (Orig.)

  13. Research on Fast Track Surgery Application in Lung Cancer Surgery

    Directory of Open Access Journals (Sweden)

    Kaiyun YANG

    2010-02-01

    Full Text Available Background and objective Fast track surgery (FTS is a systematical method to accelerate the recovery of surgical patients by reducing the physical and mental trauma stress of them. The research is to investigate the feasibility of FTS application in lung cancer surgery. Methods A total of 80 cases of lung cancer patients with single leaf lobotomy resection were randomized into two groups. While the experimental group was treated with the conception of FTS, and the control group was treated with the traditional methods. The incident rate of post-operation pain degrees, telecasts, pleural effusion, the post-operation time stay in hospital time and the total cost during hospitalization in two groups were compared respectively. Results In FTS group: the VAS score of post-operation pain at 1 h, 6 h, 12 h, 24 h and 48 h all significantly decreased compared to the traditional therapy group. The incidence rate of telecast was 10.53%. The incidence rate of pleural effusion was 26.31%. The length of stay after operation was (4±1 d and the total cost was RMB 15 600±7 600. In the control group, the above values were 77.78%, 33.33%, 22.22%, (9±1 d, RMB 23 600±5 400, respectively. The post operation pain (VAS method of FTS group was remarkablely below the control group. There has significant difference of the incident rate of telecasts, stay time in hospital and the total cast in two groups (P < 0.05. No significant difference was observed in the incident rate of pleural effusion. Conclusion The new methods of FTS can apparently accelerates recovery after lung cancer resection, reduces complications, shorten timestay in hospital and cut down the total cost.

  14. Fast Track Characterization of Highly Radioactive Waste Pits Combining Off-the-Shelf Robotics with Innovative Investigation Protocols

    International Nuclear Information System (INIS)

    Chabeuf, Jean-Michel; Boya, Didier

    2008-01-01

    The investigation and characterization of radioactive waste pits and effluent storage tanks represents a substantial and challenging step in the overall decommissioning programme launched by AREVA NC in 1998 on the site of Marcoule on behalf of the French Atomic Energy commission. Physical ,radiological and regulatory constraints, combined with a tight schedule, have lead our teams to use proven conventional instrumentation and robotics in innovative configurations . One such investigation, conducted on a particularly challenging radioactive effluent storage pit, is described below. The 'H' pit is a stainless steel clad concrete cavity, located in the second basement of the de-cladding building of Marcoule site. It was used for forty years as buffer storage for high activity effluents and has a length of 5 meters, a width of 3 meters , a height of 2.5 meters, and is topped by lead plates over 5 cm thick and The bottom of the cavity is covered with a layer of mud containing mainly graphite, diatoms and resins. The mud level ranges from about 20 centimeters to over 50 centimeters. The overall mud volume is around 2.4 cubic meters. Ambient dose rates above the lead plates exceed 10 mSv/h. The main purpose of our investigation was to characterize the muds for future recovery and conditioning prior to decontaminating the pit. The history of the pit together with the varying mud altimetry lead us to believe that sedimentation had probably occurred throughout the years. We thus decided to combine dose rate measurements using IF104 probes, gamma spectroscopy with CdTe probes and sample collections at different depths to ensure the representativeness and full characterization of the muds. Poor access, ambient dose rates have lead us to conceive a robotic arm, mounted on an shaft which can be modified to fit a wide range of pits and tanks. Custom built robotic tools with maximum manoeuvrability generally involve costs and delays far exceeding our purposes. SIT, a French

  15. 15th Kassel symposium energy systems technology. Renewable energy sources and E-mobility. Proceedings; 15. Kasseler Symposium Energie-Systemtechnik. Erneuerbare Energien und E-Mobilitaet. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 15th Kassel symposium of power system engineering from 23th to 24th September, 2010, in Kassel (Federal Republic of Germany) the following lectures were held: (1) Transformation of energy systems and electromobility (Juergen Schmid); (2) Electromobility and renewable energies - scenarios and perspectives (Michael Weinhold); (3) Fraunhofer systems research electromobility (Ulrich Buller); (4) Renewable energies and electromobility - research promotion of the BMU (Alexander Folz); (5) Lithium ion batteries - a key component for electric vehicles (Klaus Brandt); (6) Virtual batteries and electromobility (Peter Caselitz); (7) Integration of electric vehicles into the grid - grid-to-vehicle (Zbigeniew Styczynski); (8) Intelligent grid interfaces for electric vehicles (Ulrich Reker); (9) Contactless grid connection of electric vehicles (Ulrich Reker); (10) Current converters for electric vehicles (Peter Zacharias); (11) Vehicle to grid communication interface (Joerg Heuer); (12) Business models electromobility (Anke Weidlich); (13) Hydrogen and electromobility - a future model? (Hubert Landinger).

  16. Measuring and enabling learning behavior in product innovation processes

    NARCIS (Netherlands)

    Gieskes, J.F.B.; van der Heijden, Beatrice

    2004-01-01

    It is generally acknowledged that innovation is one of the most important predictors of firm success or failure. Successful innovation processes require creating new organizational capabilities to handle the external pressure for new products and processes (fast, good and at low costs), and the

  17. Tracking clinical competencies on the web.

    Science.gov (United States)

    Hobbs, Dan L

    2005-01-01

    The American Registry of Radiologic Technologists (ARRT) has defined several core examinations that student radiographers must perform to demonstrate competency. Furthermore, the ARRT has left the method of tracking competency exams to educators. This article describes a Web-based system that can be used to track clinical competencies. The pedagogy employed in designing a meaningful and successful Web site to track competencies can be overwhelming. Considerations include selecting software, the design and implementation process, and providing security to protect confidential information. The Web-based system described in this article is innovative, sensible and relatively easy to adopt. This tracking method provides faculty members with instantaneous access and a quick review of the student's competency examinations. Students' competency information for the entire program is contained in 1 electronic file. With minor modification, the system can be used in a variety of educational and administrative settings.

  18. The Multiplicity of Controls and the Making of Innovation

    DEFF Research Database (Denmark)

    Revellino, Silvana; Mouritsen, Jan

    2009-01-01

    are mediated by unique sets of technologies of control. In this process the innovation changes and adapts. This thesis is drawn from the case of Italian Autostrade's innovation Telepass which was an automatic toll collection devise developed to make traffic fast, safe and fluid. Throughout its development...... satisfaction, productivity and highly pointed achievement targets. This multiplicity of controls changed and adapted to the innovation as the innovation unfolds. The controls were part of the innovation more likely than an external device to make it transparent. They engaged the individual trials and changed...

  19. The ATLAS Fast TracKer Processing Units

    CERN Document Server

    Krizka, Karol; The ATLAS collaboration

    2016-01-01

    The Fast Tracker is a hardware upgrade to the ATLAS trigger and data-acquisition system, with the goal of providing global track reconstruction by the start of the High Level Trigger starts. The Fast Tracker can process incoming data from the whole inner detector at full first level trigger rate, up to 100 kHz, using custom electronic boards. At the core of the system is a Processing Unit installed in a VMEbus crate, formed by two sets of boards: the Associative Memory Board and a powerful rear transition module called the Auxiliary card, while the second set is the Second Stage board. The associative memories perform the pattern matching looking for correlations within the incoming data, compatible with track candidates at coarse resolution. The pattern matching task is performed using custom application specific integrated circuits, called associative memory chips. The auxiliary card prepares the input and reject bad track candidates obtained from from the Associative Memory Board using the full precision a...

  20. Slow and Fast Light, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In response to the NASA Small Business Innovation Research (SBIR) Program 2015 Phase I Solicitation S3.08: Slow and Fast Light, Torch Technologies in partnership...

  1. Finding very small near-Earth asteroids using synthetic tracking

    International Nuclear Information System (INIS)

    Shao, Michael; Nemati, Bijan; Zhai, Chengxing; Turyshev, Slava G.; Sandhu, Jagmit; Hallinan, Gregg; Harding, Leon K.

    2014-01-01

    We present an approach that significantly increases the sensitivity for finding and tracking small and fast near-Earth asteroids (NEAs). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively 'freezing' their motion, and a computationally enhanced implementation of the 'shift-and-add' data processing technique that helps to improve the signal-to-noise ratio (SNR) for detection of NEAs. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive frames relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call 'synthetic tracking,' enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEAs in near real time. We discuss also how synthetic tracking improves the astrometry of fast-moving NEAs. We apply this technique to observations of two known asteroids conducted on the Palomar 200 inch telescope and demonstrate improved SNR and 10 fold improvement of astrometric precision over the traditional long-exposure approach. In the past 5 yr, about 150 NEAs with absolute magnitudes H = 28 (∼10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin) 2 on the Palomar 200 inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.

  2. Finding very small near-Earth asteroids using synthetic tracking

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Michael; Nemati, Bijan; Zhai, Chengxing; Turyshev, Slava G.; Sandhu, Jagmit [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109-0899 (United States); Hallinan, Gregg; Harding, Leon K. [California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2014-02-10

    We present an approach that significantly increases the sensitivity for finding and tracking small and fast near-Earth asteroids (NEAs). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively 'freezing' their motion, and a computationally enhanced implementation of the 'shift-and-add' data processing technique that helps to improve the signal-to-noise ratio (SNR) for detection of NEAs. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive frames relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call 'synthetic tracking,' enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEAs in near real time. We discuss also how synthetic tracking improves the astrometry of fast-moving NEAs. We apply this technique to observations of two known asteroids conducted on the Palomar 200 inch telescope and demonstrate improved SNR and 10 fold improvement of astrometric precision over the traditional long-exposure approach. In the past 5 yr, about 150 NEAs with absolute magnitudes H = 28 (∼10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin){sup 2} on the Palomar 200 inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.

  3. Fast-track surgery protocol in elderly patients undergoing laparoscopic radical gastrectomy for gastric cancer: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Liu G

    2016-06-01

    Full Text Available Guozheng Liu,1 Fengguo Jian,2 Xiuqin Wang,2 Lin Chen1 1Department of General Surgery, Chinese PLA General Hospital, Beijing, People’s Republic of China; 2Second Department of General Surgery, Changyi People’s Hospital, Shandong, People’s Republic of China Aim: To study the efficacy of the fast-track surgery (FTS program combined with laparoscopic radical gastrectomy for elderly gastric cancer (GC patients.Methods: Eighty-four elderly patients diagnosed with GC between September 2014 and August 2015 were recruited to participate in this study and were divided into four groups randomly based on the random number table as follows: FTS + laparoscopic group (Group A, n=21, FTS + laparotomy group (Group B, n=21, conventional perioperative care (CC + laparoscopic group (Group C, n=21, and CC + laparotomy group (Group D, n=21. Observation indicators include intrasurgery indicators, postoperative recovery indicators, nutritional status indicators, and systemic stress response indicators.Results: Preoperative and intraoperative baseline characteristics showed no significant differences between patients in each group (P>0.05. There were no significant differences between each group in nausea and vomiting, intestinal obstruction, urinary retention, incision infection, pulmonary infection, and urinary tract infection after operation (P>0.05. Time of first flatus and postoperative hospital stay time of FTS Group A were the shortest, and total medical cost of this group was the lowest. For all groups, serum albumin, prealbumin, and transferrin significantly decreased, while CRP and interleukin 6 were significantly increased postoperative day 1. From postoperative day 4–7, all indicators of the four groups gradually recovered, but compared with other three groups, those of Group A recovered fastest.Conclusion: FTS combined with laparoscopic surgery can promote faster postoperative recovery, improve early postoperative nutritional status, and more

  4. The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events

    CERN Document Server

    INSPIRE-00249819; Appelshauser, H.; Bablok, S.; Bialas, N.; Bolgen, R.; Bonnes, U.; Bramm, R.; Braun-Munzinger, P.; Campagnolo, R.; Christiansen, P.; Dobrin, A.; Engster, C.; Fehlker, D.; Foka, Y.; Frankenfeld, U.; Gaardhoje, J.J.; Garabatos, C.; Glassel, P.; Gonzalez Gutierrez, C.; Gros, P.; Gustafsson, H.A.; Helstrup, H.; Hoch, M.; Ivanov, M.; Janik, R.; Junique, A.; Kalweit, A.; Keidel, R.; Kniege, S.; Kowalski, M.; Larsen, D.T.; Lesenechal, Y.; Lenoir, P.; Lindegaard, N.; Lippmann, C.; Mager, M.; Mast, M.; Matyja, A.; Munkejord, M.; Musa, L.; Nielsen, B.S.; Nikolic, V.; Oeschler, H.; Olsen, E.K.; Oskarsson, A.; Osterman, L.; Pikna, M.; Rehman, A.; Renault, G.; Renfordt, R.; Rossegger, S.; Rohrich, D.; Roed, K.; Richter, M.; Rueshmann, G.; Rybicki, A.; Sann, H.; Schmidt, H.R.; Siska, M.; Sitar, B.; Soegaard, C.; Soltveit, H.K.; Soyk, D.; Stachel, J.; Stelzer, H.; Stenlund, E.; Stock, R.; Strmen, P.; Szarka, I.; Ullaland, K.; Vranic, D.; Veenhof, R.; Westergaard, J.; Wiechula, J.; Windelband, B.

    2010-01-01

    The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate result...

  5. The Fast TracKer

    CERN Document Server

    Potamianos, Karolos Jozef; The ATLAS collaboration

    2018-01-01

    The Fast Tracker (FTK) is a hardware upgrade to the ATLAS trigger and data acquisition system providing global track reconstruction to the High-Level Trigger (HLT) with the goal to improve pile-up rejection. The FTK processes incoming data from the Pixel and SCT detectors (part of the Inner Detector, ID) at up to 100 kHz using custom electronic boards. ID hits are matched to pre-defined track patterns stored in associative memory (AM) on custom ASICs and data routing, reduction and parameter extraction is achieved with processing on FPGAs. With 8000 AM chips and 2000 FPGAs, the FTK provides enough resources to reconstruct tracks with transverse momentum greater than 1 GeV/c in the whole tracking volume with an average latency below 100 microseconds at collisions intensities expected in Runs II and III of the LHC. The tracks will be available at the beginning of the trigger selection process, which allows development of pile-up resilient triggering strategies to identify b-quarks and tau-leptons, as well as pr...

  6. Deformable Models for Eye Tracking

    DEFF Research Database (Denmark)

    Vester-Christensen, Martin; Leimberg, Denis; Ersbøll, Bjarne Kjær

    2005-01-01

    A deformable template method for eye tracking on full face images is presented. The strengths of the method are that it is fast and retains accuracy independently of the resolution. We compare the me\\$\\backslash\\$-thod with a state of the art active contour approach, showing that the heuristic...

  7. The management of complex system innovations. A theoretic approach to network formation and critical success factor identification using the case of fuel cell vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Venghaus, Sandra

    2011-07-01

    Given the economic, ecological and social importance of automotive transportation, the development of alternative fueling and propulsion technologies requires a wise and sustainable political course of action. Not least the public debate on the impact of transport emissions on climate change and the call for limits to automotive CO-2-emissions reflect the relevance of the topic. In the search for innovative alternatives to the conventional gasoline or diesel propulsion technology, electromobility and hydrogen-based fuel cell vehicles constitute the two most widely discussed long-term options. The market introduction of fuel cell vehicles serves as an expedient example of a highly complex system innovation (CSI), which requires the cooperation of a variety of actors from formerly independent economic sectors in order to overcome the significant barriers to market entry. As will be discussed, such CSI can only be successfully implemented in an environment, within which the complexity-induced knowledge gap is reduced by a systematic exchange of information with respect to both the critical success factors identified by each of the involved stakeholders as well as their cooperation needs and expectations. Given this challenge, a framework is developed, which serves as the basis for a structured dialogue among the multiple stakeholders involved in the development process of a complex system innovation. The framework can thus best be classified as a corporate moderation and decision-support tool to achieve transparency in and impose structure on complex contexts. Methodically, the presented thesis addresses the development of a holistic approach to the management of complex system innovations from two perspectives: (1) a theoretical perspective of analyzing underlying structures and processes of CSI management (i.e., the CSI Management Framework), as well as (2) the development of a strategic approach for the practical implementation of CSI management in complex networks

  8. Chemical etching studies of a Brazilian polycarbonate to fast neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Souto, E.B.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, IPEN- CNEN/SP Radiation Metrology Center (CMR) Av. Prof. Lineu Prestes, 2242 CEP: 05508-000 Sao Paulo - SP (Brazil)]. e-mail: ebsouto@ipen.br

    2006-07-01

    The Dosimetric Materials Laboratory (LMD) of the Radiation Metrology Center (CMR) is developing a personal dosimeter for fast neutrons using the technique of solid state nuclear track detectors (SSNTD). This technique is based on the recorded damage (tracks) in dielectric materials due to the impact of charged particles. The tracks are revealed and amplified for visualization in optic microscope through a technique known as chemical etching. The LMD is investigating a Brazilian commercial polycarbonate as a new passive fast neutron's detector in substitution to the traditional materials, as the cellulose nitrate LR-115 and the polycarbonates Makrofol and CR-39. The variation of the etching parameters (chemical solution, time and temperature) alters the response of the material; the best revelation conditions provide the best relationship among the amount of revealed tracks, their clearness and the time spent for this. The polycarbonate studied is a resin of same chemical monomer of Makrofol (C,6H,403). Samples of 3 x 1 cm{sup 2} of the polycarbonate were irradiated with 5 mSv of fast neutrons ({sup 241}Am-Be) and revealed with the chemical solution PEW-40 (15% KOH, 45% H{sub 2}O, 40% C{sub 2}H{sub 5}OH), commonly used for Makrofol. The studied etching parameters were time and temperature. Groups of four samples were revealed at temperatures of 50, 65, 75, 90 and 100 C with etching times varying from one to six hours. The used track's counting procedure was that referred in the literature. The best response to fast neutrons was obtained at 75 C; in spite of their similar answers, smaller temperatures join larger uncertainties in the track's counting and poorer clearness. At this temperature, the number of revealed tracks increases with the etching time approximately until a plateau at three hours. For etching times higher than four hours the polycarbonate presents overlap of tracks. If the temperature is adjusted to 75 C, the etching time should be in

  9. The ATLAS Fast Tracker

    CERN Document Server

    Volpi, Guido; The ATLAS collaboration

    2015-01-01

    The use of tracking information at the trigger level in the LHC Run II period is crucial for the trigger an data acquisition (TDAQ) system. The tracking precision is in fact important to identify specific decay products of the Higgs boson or new phenomena, a well as to distinguish the contributions coming from many contemporary collisions that occur at every bunch crossing. However, the track reconstruction is among the most demanding tasks performed by the TDAQ computing farm; in fact, full reconstruction at full Level-1 trigger accept rate (100 KHz) is not possible. In order to overcome this limitation, the ATLAS experiment is planning the installation of a specific processor: the Fast Tracker (FTK), which is aimed at achieving this goal. The FTK is a pipeline of high performance electronic, based on custom and commercial devices, which is expected to reconstruct, with high resolution, the trajectories of charged tracks with a transverse momentum above 1 GeV, using the ATLAS inner tracker information. Patte...

  10. The design and construction of the ZEUS central tracking detector

    Energy Technology Data Exchange (ETDEWEB)

    Foster, B.; Malos, J.; Saxon, D.H.; Clark, D.E.; Jamdagni, A.K.; Markou, C.; Miller, D.B.; Miller, D.G.; Toudup, L.W.; Auty, C.G.; Blair, G.A.; Brooks, C.B.; Cashmore, R.J.; Hanford, A.T.; Harnew, N.; Holmes, A.R.; Linford, W.; Martin, N.C.; McArthur, I.C.; Nash, J.; Nobbs, K.N.; Wastie, R.L.; Williams, M.T.; Wilson, F.F.; Wilson, R.D.; Hart, J.C.; Hatley, R.W.; Hiddleston, J.W.; Gibson, M.D.; McCubbin, N.A.; Middleton, A.; Morrissey, M.C.; Morrow, D.; O' Brien, P.; Payne, B.T.; Roberts, J.C.H.; Shaw, T.B.; Sinclair, C.K.; Wallis, E.W.G.; White, D.J.; Yeo, K.L.; Bullock, F.W.; Dumper, J.; Fraser, T.J.; Hayes, D.; Jones, T.W.; Strachan, D.E.; Vine, I.A. (H.H. Wills Physics Lab., Univ. of Bristol (United Kingdom) Dept. of Physics and Astronomy, Univ. of Glasgow (United Kingdom) Blackett Lab., Physics Dept., Imperial Coll., London (United Kingdom) Dept. of Physics, Nuclear Physics Lab., Univ. of Oxford (United Kingdom) Rutherford Appleton Lab., Chilton (United Kingdom) Dept. of Physics an

    1994-01-15

    The mechanical, electrical and electronic design and construction of the ZEUS central tracking detector are described, together with the chamber monitoring and environmental control. This cylindrical drift chamber is designed for track reconstruction, electron identification and fast event triggering in a high beam-crossing rate, high magnetic field application. (orig.)

  11. The Fast Simulation Chain for ATLAS

    CERN Document Server

    Basalaev, Artem; The ATLAS collaboration

    2016-01-01

    In order to generate the huge number of Monte Carlo events that will be required by the ATLAS experiment over the next several runs, a very fast simulation is critical. Fast detector simulation alone, however, is insufficient: with very high numbers of simultaneous proton-proton collisions expected in Run 3 and beyond, the digitization (detector response emulation) and event reconstruction time quickly become comparable to the time required for detector simulation. The ATLAS Fast Chain simulation has been developed to solve this problem. Modules are implemented for fast simulation, fast digitization, and fast track reconstruction. The application is sufficiently fast -- several orders of magnitude faster than the standard simulation -- that the simultaneous proton-proton collisions can be generated during the simulation job, so Pythia8 also runs concurrently with the rest of the algorithms. The Fast Chain has been built to be extremely modular and flexible, so that each sample can be custom-tailored to match ...

  12. Fast track segment finding in the Monitored Drift Tubes of the ATLAS Muon Spectrometer using a Legendre transform algorithm

    CERN Document Server

    Ntekas, Konstantinos; The ATLAS collaboration

    2018-01-01

    The upgrade of the ATLAS first-level muon trigger for High- Luminosity LHC foresees incorporating the precise tracking of the Monitored Drift Tubes in the current system based on Resistive Plate Chambers and Thin Gap Chambers to improve the accuracy in the transverse momentum measurement and control the single muon trigger rate by suppressing low quality fake triggers. The core of the MDT trigger algorithm is the segment identification and reconstruction which is performed per MDT chamber. The reconstructed segment positions and directions are then combined to extract the muon candidate’s transverse momentum. A fast pattern recognition segment finding algorithm, called the Legendre transform, is proposed to be used for the MDT trigger, implemented in a FPGA housed on a ATCA blade.

  13. Global track finder for Belle II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Trusov, Viktor; Feindt, Michael; Heck, Martin; Kuhr, Thomas; Goldenzweig, Pablo [Karlsruhe Institute of Technology, IEKP (Germany); Collaboration: Belle II-Collaboration

    2015-07-01

    We present an implementation of a method based on the Legendre transformation for reconstruction charged particle tracks in the central drift chamber of the Belle II experiment. The method is designed for fast track finding and restoring circular patterns of track hits in transverse plane. It is done by searching for common tangents to drift circles of hits in the conformal space. With known transverse trajectories longitudinal momentum estimation performed by assigning stereo hits followed by determination of the track parameters. The method includes algorithms responsible for track quality estimation and reduction of rate of fakes. The work is targeting at increasing the efficiency and reducing the execution time because the computing power available to the experiment is limited. The algorithm is developed within the Belle II software environment with using Monte-Carlo simulation for probing its efficiency.

  14. Fast region-based object detection and tracking using correlation of features

    CSIR Research Space (South Africa)

    Senekal, F

    2010-11-01

    Full Text Available and track a target object (or objects) over a series of digital images. Visual target tracking can be accomplished by feature-based or region-based approaches. In feature-based approaches, interest points are calculated in a digital image, and a local...-time performance based on the computational power that is available on a specific platform. To further reduce the computational requirements, process- ing is restricted to the region of interest (ROI). The region of interest is provided as an input parameter...

  15. Method-centered digital communities on protocols.io for fast-paced scientific innovation [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Lori Kindler

    2017-06-01

    Full Text Available The Internet has enabled online social interaction for scientists beyond physical meetings and conferences. Yet despite these innovations in communication, dissemination of methods is often relegated to just academic publishing. Further, these methods remain static, with subsequent advances published elsewhere and unlinked. For communities undergoing fast-paced innovation, researchers need new capabilities to share, obtain feedback, and publish methods at the forefront of scientific development. For example, a renaissance in virology is now underway given the new metagenomic methods to sequence viral DNA directly from an environment. Metagenomics makes it possible to "see" natural viral communities that could not be previously studied through culturing methods. Yet, the knowledge of specialized techniques for the production and analysis of viral metagenomes remains in a subset of labs.  This problem is common to any community using and developing emerging technologies and techniques. We developed new capabilities to create virtual communities in protocols.io, an open access platform, for disseminating protocols and knowledge at the forefront of scientific development. To demonstrate these capabilities, we present a virology community forum called VERVENet. These new features allow virology researchers to share protocols and their annotations and optimizations, connect with the broader virtual community to share knowledge, job postings, conference announcements through a common online forum, and discover the current literature through personalized recommendations to promote discussion of cutting edge research. Virtual communities in protocols.io enhance a researcher's ability to: discuss and share protocols, connect with fellow community members, and learn about new and innovative research in the field.  The web-based software for developing virtual communities is free to use on protocols.io. Data are available through public APIs at protocols.io.

  16. Pose Tracking Algorithm of an Endoscopic Surgery Robot Wrist

    International Nuclear Information System (INIS)

    Wang, L; Yin, H L; Meng, Q

    2006-01-01

    In recent two decades, more and more research on the endoscopic surgery has been carried out [2]. Most of the work focuses on the development of the robot in the field of robotics and the navigation of the surgery tools based on computer graphics. But the tracking and locating of the EndoWrist is also a very important aspect. This paper deals with the the tracking algorithm of the EndoWrist's pose (position and orientation). The linear tracking of the position is handled by the Kalman Filter. The quaternion-based nonlinear orientation tracking is implemented with the Extended Kalman Filter. The most innovative point of this paper is the parameterization of the motion model of the Extended Kalman Filter

  17. Study and Evaluation of Innovative Fuel Handling Systems for Sodium-Cooled Fast Reactors: Fuel Handling Route Optimization

    Directory of Open Access Journals (Sweden)

    Franck Dechelette

    2014-01-01

    Full Text Available The research for technological improvement and innovation in sodium-cooled fast reactor is a matter of concern in fuel handling systems in a view to perform a better load factor of the reactor thanks to a quicker fuelling/defueling process. An optimized fuel handling route will also limit its investment cost. In that field, CEA has engaged some innovation study either of complete FHR or on the optimization of some specific components. This paper presents the study of three SFR fuel handling route fully described and compared to a reference FHR option. In those three FHR, two use a gas corridor to transfer spent and fresh fuel assembly and the third uses two casks with a sodium pot to evacuate and load an assembly in parallel. All of them are designed for the ASTRID reactor (1500 MWth but can be extrapolated to power reactors and are compatible with the mutualisation of one FHS coupled with two reactors. These three concepts are then intercompared and evaluated with the reference FHR according to four criteria: performances, risk assessment, investment cost, and qualification time. This analysis reveals that the “mixed way” FHR presents interesting solutions mainly in terms of design simplicity and time reduction. Therefore its study will be pursued for ASTRID as an alternative option.

  18. The ATLAS Fast Tracker Processing Units - input and output data preparation

    CERN Document Server

    Bolz, Arthur; Adelman, Jahred; Anderson, John Thomas; Armbruster, Aaron James; Asbah, Nedaa; Blair, Robert; Brost, Elizabeth; Drake, Gary; Gkaitatzis, Stamatios; Iizawa, Tomoya; Ilic, Nikolina; Jiang, Zihao; Kawaguchi, Yoshimasa; Kimura, Naoki; Kordas, Kostantinos; Sotiropoulou, Calliope Louisa; Love, Jeremy; Mitani, Takashi; Nikolaidis, Spyridon; Okumura, Yasuyuki; Proudfoot, James; Thayil, Steffie Ann; Tompkins, Lauren; Wang, Rui; Watari, Ryutaro; Webster, Jordan S; Yorita, Kohei; Zhang, Jinlong

    2017-01-01

    The ATLAS Fast TracKer(FTK) is a custom hardware system for fast, associative memory based track reconstruction. It will provide tracking information within the full acceptance of the inner tracking detectors to the high level trigger at a rate of up to 100 kHz. %, thus allowing for a refined and more efficient event selection at the trigger level. At the first stage of the FTK the Data Formatter subsystem clusters inner detector hits and organizes them into 64 $\\eta$-$\\phi$ trigger regions. At the last stage, the FTK to Level-2 Interface Cards repackage track records and send them to the high level trigger computing farm. This report aims to give an overview over the functionality of the two systems, their hardware implementation in the Advanced Telecommunications Computing Architecture standard, and the status of their integration into ATLAS.

  19. The ATLAS Fast Tracker Processing Units - input and output data preparation

    CERN Document Server

    Bolz, Arthur; Adelman, Jahred; Anderson, John Thomas; Armbruster, Aaron James; Asbah, Nedaa; Blair, Robert; Brost, Elizabeth; Drake, Gary; Gkaitatzis, Stamatios; Iizawa, Tomoya; Ilic, Nikolina; Jiang, Zihao; Kawaguchi, Yoshimasa; Kimura, Naoki; Kordas, Kostantinos; Sotiropoulou, Calliope Louisa; Love, Jeremy; Mitani, Takashi; Nikolaidis, Spyridon; Okumura, Yasuyuki; Proudfoot, James; Thayil, Steffie Ann; Tompkins, Lauren; Wang, Rui; Watari, Ryutaro; Webster, Jordan S; Yorita, Kohei; Zhang, Jinlong

    2016-01-01

    The ATLAS Fast TracKer(FTK) is a custom hardware system for fast, associative memory based track reconstruction. It will provide tracking information within the full acceptance of the inner tracking detectors to the high level trigger at a rate of up to 100 kHz. %, thus allowing for a refined and more efficient event selection at the trigger level. At the first stage of the FTK the Data Formatter subsystem clusters inner detector hits and organizes them into 64 $\\eta$-$\\phi$ trigger regions. At the last stage, the FTK to Level-2 Interface Cards repackage track records and send them to the high level trigger computing farm. This report aims to give an overview over the functionality of the two systems, their hardware implementation in the Advanced Telecommunications Computing Architecture standard, and the status of their integration into ATLAS.

  20. Dark Innovation, An Interview with Jerry Michalski, by Peter J. Denning

    OpenAIRE

    Denning, Peter J.; Michalski, Jerry

    2012-01-01

    The article of record as published may be found at http://dx.doi.org/10. Editor's Introduction: As computing technologists, we tend to think of innovations in terms of new products or services supported by, or made of, computing technologies. But there are other types of innovation besides products. There are process innovations, such as McDonald’s method of making hamburgers fast; social innovations, such as Mothers Against Drunk Driving; and business model innovations, such as Starbucks ...

  1. Auger processes in tracks of fast multicharged ions

    International Nuclear Information System (INIS)

    Katin, V.V.; Martynenko, Yu.V.; Yavlinskij, Yu.N.

    1992-01-01

    The fast multicharged ion spends about 40% of energy losses on vacancy creation in the inner electron shells. This energy is transferred to the kinetic energy of electrons due to the cascade of Auger processes during ∼ 10 -14 s whereas the primary excited electrons receive the energy in ∼10 -16 s. (author)

  2. Adopting preoperative fasting guidelines.

    Science.gov (United States)

    Anderson, Megan; Comrie, Rhonda

    2009-07-01

    In 1999, the American Society of Anesthesiologists adopted preoperative fasting guidelines to enhance the quality and efficiency of patient care. Guidelines suggest that healthy, non-pregnant patients should fast six hours from solids and two hours from liquids. Although these guidelines are in place, studies suggest that providers are still using the blanket statement "NPO after midnight" without regard to patient characteristics, the procedure, or the time of the procedure. Using theory to help change provider's beliefs may help make change more successful. Rogers' Theory of Diffusion of Innovations can assist in changing long-time practice by laying the groundwork for an analysis of the benefits and disadvantages of proposed changes, such as changes to fasting orders, while helping initiate local protocols instead of additional national guidelines.

  3. Just charge it. Electromobility for the future; Einfach aufladen. Mit Elektromobilitaet in eine neue Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    Canzler, Weert; Knie, Andreas

    2011-07-01

    By 2020, more than one million electric-powered vehicles are envisaged on German roads. But when will they be commercially available? How much power do they really consume? Will there be batteries with sufficient capacity? And wouldn't it be more sensible to make conventional cars more efficient? These and other questions about electric-powered cars and electromobility are answered by the authors, competently and in a manner that also addresses the non-expert public. It is shown that electric-powered cars will be operated in fleets, serving not only as vehicles but also as buffers for renewables-derived power, which is known to be volatile. Controlled charging will offer a solution. Professionally managed fleets of electric-powered vehicles can store excess wind power, or they could serve as buffers at noon when more solar power is generated than is required in factories and kitchens. [German] Bis zum Jahr 2020 sollen ueber hiesige Strassen eine Million Elektroautos rollen. Doch wann werden Elektrofahrzeuge in nennenswertem Ausmass angeboten? Wie hoch ist ihr Strombedarf wirklich? Ist in naher Zukunft mit leistungsfaehigen Batterien zu rechnen? Und waere es nicht sinnvoller, konventionell betriebene Autos effizienter zu machen? Kompetent und fuer den Laien verstaendlich beantworten die Autoren diese und weitere Fragen rund um das Thema Elektroauto und Elektromobilitaet. Demnach werden die Elektroautos in Flotten betrieben und dienen nicht nur als Verkehrsmittel, sondern zugleich als Puffer fuer die bekanntlich volatilen erneuerbaren Energien. Die Formel lautet hier: gesteuertes Laden. Professionell in Flotten gemanagte Elektrofahrzeuge koennen ueberschuessigen Windstrom aufnehmen, wenn beispielsweise nachts die Abnahme fehlt, oder sie koennen als Puffer bereit stehen fuer die Mittagsstunden, wenn mehr Sonnenstrom produziert wird als in den Fabriken und Kuechen benoetigt wird.

  4. Integrated quality status and inventory tracking system for FFTF driver fuel pins

    International Nuclear Information System (INIS)

    Gottschalk, G.P.

    1979-11-01

    An integrated system for quality status and inventory tracking of Fast Flux Test Facility (FFTF) driver fuel pins has been developed. Automated fuel pin identification systems, a distributed computer network, and a data base are used to implement the tracking system

  5. Innovation activity as a condition for growing companied to improve their competitiveness

    Directory of Open Access Journals (Sweden)

    V. A. Barinova

    2015-01-01

    Full Text Available This article was conducted to identify the impact of innovative and scientific activities on competitiveness of fast growing Russian companies. The authors demonstrated that the competitiveness of domestic companies depends on their expenditures on R&D and technological innovation, the costs of staff training and other factors. Dataset for the study is based on the national ranking of fast-growing high-tech companies «TechUp 2013».

  6. Use of cellulose nitrate plastic track detectors in neutron personnel monitoring

    International Nuclear Information System (INIS)

    Venkataraman, G.; Marathe, P.K.; Joshi, R.V.

    1975-01-01

    Cellulose nitrate, which is a sensitive plastic material wherein even proton tracks could be recorded, was studied with a view to using it for personnel neutron monitoring work. It was found that among the commercially available plastics, the colourless transparent Daicel 6000 variety having a thickness of 0.6mm is satisfactory form the point of view of track recognition. The material was exposed to thermal neutrons, fission neutrons, neutrons from an Am-Be source and to 14 MeV neutrons. As is to be expected, there is no thermal neutron sensitivity. The sensitivity to fast neutrons is less by a factor of two as compared to that of the NTA nuclear track emulsion. It was observed that the background tracks found in the plastic correspond to nearly 100 mrem of fast neutron dose equivalent. It is felt that at present cellulose nitrate is useful for monitoring personnel involved in nuclear criticality accidents. (author)

  7. Fast processor for dilepton triggers

    International Nuclear Information System (INIS)

    Katsanevas, S.; Kostarakis, P.; Baltrusaitis, R.

    1983-01-01

    We describe a fast trigger processor, developed for and used in Fermilab experiment E-537, for selecting high-mass dimuon events produced by negative pions and anti-protons. The processor finds candidate tracks by matching hit information received from drift chambers and scintillation counters, and determines their momenta. Invariant masses are calculated for all possible pairs of tracks and an event is accepted if any invariant mass is greater than some preselectable minimum mass. The whole process, accomplished within 5 to 10 microseconds, achieves up to a ten-fold reduction in trigger rate

  8. Key Mechanisms for Employee-Driven Innovation in Governmental Client Organisations

    DEFF Research Database (Denmark)

    Sørensen, Henrik; Wandahl, Søren; Faber, Lene

    2018-01-01

    the mechanisms of organisational trust, innovation safety, organisational practices, cultural settings and the recognition and rewards structure to motivate employees. The decision-making procedures should be transparent especially to the idea-owner and the employees involved, and the implementation and putting......In order to ensure that knowledge and ideas are transformed into innovative contributions, a systematic approach is important. The aim of this research was to identify the specific mechanisms that are key to implementing an innovation process model when conducting Employee-driven Innovation...... into practice should be fast progressed phases in the innovation process....

  9. Global architecture of innovative nuclear energy

    International Nuclear Information System (INIS)

    Andreeva-Andrievskaya, L.N.; Kagramanyan, V.S.; Usanov, V.I.; )

    2011-01-01

    The study Global Architecture of Innovative Nuclear Energy Systems Based on Thermal and Fast Reactors including a Closed Fuel Cycle (GAINS), aimed at harmonization of tools used to assess various options for innovative development of nuclear energy, modeling of jointly defined scenarios and analysis of obtained results is presented in the paper. Objectives and methods of the study, issues of spent fuel and fissile materials management are discussed. Investment risks and economic indicators are also described [ru

  10. Design and Selection of Innovative Primary Circulation Pumps for GEN-IV Lead Fast Reactors

    Directory of Open Access Journals (Sweden)

    Walter Borreani

    2017-12-01

    Full Text Available Although Lead-cooled Fast Reactor (LFR is not a new concept, it continues to be an example of innovation in the nuclear field. Recently, there has been strong interest in liquid lead (Pb or liquid lead–bismuth eutectic (LBE both critical and subcritical systems in a relevant number of Countries, including studies performed in the frame of GENERATION-IV initiative. In this paper, the theoretical and computational findings for three different designs of Primary Circulation Pump (PCP evolving liquid lead (namely the jet pump, the Archimedean pump and the blade pump are presented with reference to the ALFRED (Advanced Lead Fast Reactor European Demonstrator design. The pumps are first analyzed from the theoretical point of view and then modeled with a 3D CFD code. Required design performance of the pumps are approximatively around an effective head of 2 bar with a mass flow rate of 5000 kg/s. Taking into account the geometrical constraints of the reactor and the fluid dynamics characteristics of the molten lead, the maximum design velocity for molten lead fluid flow of 2 m/s may be exceeded giving rise to unacceptable erosion phenomena of the blade or rotating component of the primary pumping system. For this reason a deep investigation of non-conventional axial pumps has been performed. The results presented shows that the design of the jet pump looks like beyond the current technological feasibility while, once the mechanical challenges of the Archimedean (screw pump and the fluid-dynamic issues of the blade pump will be addressed, both could represent viable solutions as PCP for ALFRED. Particularly, the blade pump shows the best performance in terms of pressure head generated in normal operation conditions as well as pressure drop in locked rotor conditions. Further optimizations (mainly for what the geometrical configuration is concerned are still necessary.

  11. The Fast Simulation Chain for ATLAS

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00399337; The ATLAS collaboration; Marshall, Zach

    2017-01-01

    In order to generate the huge number of Monte Carlo events that will be required by the ATLAS experiment over the next several runs, a very fast simulation is critical. Fast detector simulation alone, however, is insufficient: with very high numbers of simultaneous proton-proton collisions expected in Run 3 and beyond, the digitization (detector response emulation) and event reconstruction time quickly become comparable to the time required for detector simulation. The ATLAS Fast Chain simulation has been developed to solve this problem. Modules are implemented for fast simulation, fast digitization, and fast track reconstruction. The application is sufficiently fast—several orders of magnitude faster than the standard simulation—that the simultaneous proton-proton collisions can be generated during the simulation job, so Pythia8 also runs concurrently with the rest of the algorithms. The Fast Chain has been built to be extremely modular and flexible, so that each sample can be custom-tailored to match th...

  12. Preliminary In-Situ Evaluation of an Innovative, Semi-Flexible Pavement Wearing Course Mixture Using Fast Falling Weight Deflectometer.

    Science.gov (United States)

    Pratelli, Chiara; Betti, Giacomo; Giuffrè, Tullio; Marradi, Alessandro

    2018-04-16

    In the last forty, years semi-flexible pavements have been successfully employed, especially in those areas subjected to heavy and slow-moving loads. They usually comprise a wearing course of Grouted Macadam, a composite pavement material that provides significant advantages in comparison to both concrete and asphalt pavements. On the other hand, the laying process of this material is a two-stage operation, and the realization complexity leads to long realization times and high initial costs. Therefore, the use of semi-flexible pavements has been limited to some fields of application and areas. Recently, an innovative material has been developed to be used as an alternative to Grouted Macadam for semi-flexible pavement wearing course realization. This material should provide similar or even superior characteristics compared to traditional Grouted Macadam. This will reduce semi-flexible pavement construction time and avoid the need for dividing the laying process. This paper presents an experimental program involving the use of FastFWD, as an APT device, to evaluate in-situ properties and performance of this material. The achieved results regarding the validation of this new material by means of FastFWD appear promising both in terms of the material's properties and resistance to dynamic load repetitions.

  13. Preliminary In-Situ Evaluation of an Innovative, Semi-Flexible Pavement Wearing Course Mixture Using Fast Falling Weight Deflectometer

    Directory of Open Access Journals (Sweden)

    Chiara Pratelli

    2018-04-01

    Full Text Available In the last forty, years semi-flexible pavements have been successfully employed, especially in those areas subjected to heavy and slow-moving loads. They usually comprise a wearing course of Grouted Macadam, a composite pavement material that provides significant advantages in comparison to both concrete and asphalt pavements. On the other hand, the laying process of this material is a two-stage operation, and the realization complexity leads to long realization times and high initial costs. Therefore, the use of semi-flexible pavements has been limited to some fields of application and areas. Recently, an innovative material has been developed to be used as an alternative to Grouted Macadam for semi-flexible pavement wearing course realization. This material should provide similar or even superior characteristics compared to traditional Grouted Macadam. This will reduce semi-flexible pavement construction time and avoid the need for dividing the laying process. This paper presents an experimental program involving the use of FastFWD, as an APT device, to evaluate in-situ properties and performance of this material. The achieved results regarding the validation of this new material by means of FastFWD appear promising both in terms of the material’s properties and resistance to dynamic load repetitions.

  14. Application of solid state nuclear track detectors in radiation protection

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.; Mishra, U.C.

    1989-01-01

    This article reviews the current status of the application of nuclear track detectors with emphasis on recent developments in the field of radiation protection. Track etch detectors have been used for the measurements of low level radiation in the environment, fast neutron and radon daughter inhalation dose. Recent developments in the field of dosimetry seem to be promising. In fast neutron dosimetry, track etch detectors can be used without inclusion of fissile materials by using the electrochemical etching technique. These detectors can provide important information in the energy range upto 250 keV. Survey of this range of energy with TLD is difficult because they are extremely energy dependent and over-respond to low energy neutrons. Measurement of radon using track detectors can help to lower the cost of the radon dosimeters. Certain detectors are sensitive to alpha particles from radon and their progeny. Higher sensitivity permits their use in a passive type of personnel dosimeter, which does not require the troublesome aspects of air sampling for the collection of radon daughter samples. (author), 38 refs., 8 tabs., 12 figs

  15. Automotive systems engineering

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Markus [Technische Univ. Braunschweig (Germany). Inst. fuer Regelungstechnik; Winner, Hermann (eds.) [Technische Univ. Darmstadt (Germany). Fachgebiet Fahrzeugtechnik

    2013-06-01

    Innovative state-of-the-art book. Presents brand new results of a joint workshop in the field of automotive systems engineering. Recommendable to students for further reading even though not a primary text book. This book reflects the shift in design paradigm in automobile industry. It presents future innovations, often referred as ''automotive systems engineering''. These cause fundamental innovations in the field of driver assistance systems and electro-mobility as well as fundamental changes in the architecture of the vehicles. New driving functionalities can only be realized if the software programs of multiple electronic control units work together correctly. This volume presents the new and innovative methods which are mandatory to master the complexity of the vehicle of the future.

  16. Automated Measurement of Fast Mitochondrial Transport in Neurons

    Directory of Open Access Journals (Sweden)

    Kyle eMiller

    2015-11-01

    Full Text Available There is a growing recognition that fast mitochondrial transport in neurons is disrupted in multiple neurological diseases and psychiatric disorders. However a major constraint in identifying novel therapeutics based on mitochondrial transport is that the large-scale analysis of fast transport is time consuming. Here we describe methodologies for the automated analysis of fast mitochondrial transport from data acquired using a robotic microscope. We focused on addressing questions of measurement precision, speed, reliably, workflow ease, statistical processing and presentation. We used optical flow and particle tracking algorithms, implemented in ImageJ, to measure mitochondrial movement in primary cultured cortical and hippocampal neurons. With it, we are able to generate complete descriptions of movement profiles in an automated fashion of hundred of thousands of mitochondria with a processing time of approximately one hour. We describe the calibration of the parameters of the tracking algorithms and demonstrate that they are capable of measuring the fast transport of a single mitochondrion. We then show that the methods are capable of reliably measuring the inhibition of fast mitochondria transport induced by the disruption of microtubules with the drug nocodazole in both hippocampal and cortical neurons. This work lays the foundation for future large-scale screens designed to identify compounds that modulate mitochondrial motility.

  17. Trigger and electronics issues for scintillating fiber tracking

    International Nuclear Information System (INIS)

    Baumbaugh, A.E.

    1994-01-01

    Scintillating Fiber technology has made great advances and has demonstrated great promise for high speed charged particle tracking and triggering. The small detector sizes and fast scintillation floors available, make them very promising for use at high luminosity experiments at today's and tomorrow's colliding and fixed target experiments where high rate capability is essential. This paper will discuss some of the system aspects which should be considered by anyone attempting to design a scintillating fiber tracking system and high speed tracking trigger. As the reader will see, seemingly simple decisions can have far reaching effects on overall system performance

  18. Pose Tracking Algorithm of an Endoscopic Surgery Robot Wrist

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L [Chinese-German Institute of Automatic Control Engineering, Tongji University (China); Yin, H L [Chinese-German Institute of Automatic Control Engineering, Tongji University (China); Meng, Q [Shanghai University of Electric Power (China)

    2006-10-15

    In recent two decades, more and more research on the endoscopic surgery has been carried out [2]. Most of the work focuses on the development of the robot in the field of robotics and the navigation of the surgery tools based on computer graphics. But the tracking and locating of the EndoWrist is also a very important aspect. This paper deals with the the tracking algorithm of the EndoWrist's pose (position and orientation). The linear tracking of the position is handled by the Kalman Filter. The quaternion-based nonlinear orientation tracking is implemented with the Extended Kalman Filter. The most innovative point of this paper is the parameterization of the motion model of the Extended Kalman Filter.

  19. Recent developments in wire chamber tracking at SSC

    International Nuclear Information System (INIS)

    Ogren, H.

    1990-01-01

    All of the major SSC proposed detectors use wire chambers in their tracking systems. The feasibility of wire chambers in an SSC detector has now been established by a number of groups planning detectors at SSC. The major advances during the past year in understanding straw tube drift chambers are presented and several innovations in gaseous wire chambers are discussed. The R and D section will concentrate on progress in drift cell design, electronics and signal processing, and engineering aspects of the tracking designs

  20. Studies on neutron detection with solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Khouri, M.C.; Vilela, E.C.; Andrade, C. de.

    1993-03-01

    The detection of thermal and fast neutrons was studied. For thermal neutrons, alpha sensitive plastic was used in order to register the products of nuclear reactions taking place in boron and /or lithium converters. Fast neutrons produce recoil tracks within the detector. In the present case, CR-39 and Makrofol E were used. Chemical and electrochemical etching processes were used for thermal and fast neutron detectors, respectively. (F.E.). 6 refs, 4 figs, 6 tabs

  1. Television imaging system for fast neutron radiography using baby cyclotron

    International Nuclear Information System (INIS)

    Yoshii, Koji; Miya, Kenzo; Katoh, Norihiko.

    1993-01-01

    A television imaging system for fast neutron radiography (FNR-TV) developed using the fast neutron source reactor YAYOI was applied to the baby-cyclotron based fast neutron source to get images of thick objects quickly. In the system the same technique as a current television imaging system of thermal neutron radiography was applied, while the luminescent converter was used to detect fast neutrons. Using the CR39 track etch method it took about 7 h to get an image, while the FNR-TV only 20 s enough for taking the same object. However the FNR-TV imaging result of the simulation model of a large explosive device for the space launch vehicle of H-2 type was not so good as the image taken with the CR39 track etch method. The reason was that the luminescence intensity of the FNR-TV converter was a quarter of that in the YAYOI. (author)

  2. MONICA - an on-line track following microprocessor in high energy physics experiments

    International Nuclear Information System (INIS)

    Wermes, N.; Schildt, P.; Stuckenberg, H.J.

    1980-02-01

    In the storage ring experiments at the PETRA accelerator, large cylindrical detectors with thousands of channels are used. The maximum event rate is 500 000 per second, i.e. effective preprocessing is required. In the TASSO detector this is achieved in two steps: A fast trigger system is able to make within 1 microsecond a decision, whether it is a useful event or not. A positive decision starts an on-line track-following ECL computer together with fast associative memories and table look-up. It is a microprogrammed on-line track analyzer called MONICA, which follows up to 10 tracks within 1 millisecond and calculates the coordinates in the R,phi-plane. CAMAC equipment is used for the input of raw data and the output of the calculated track coordinates, speed of the system is ensured by the computer. An outline of the algorithm used and the features of MONICA are given. As far as we know MONICA is the first running on-line track following free programmable microporcessor used in storage ring experiments. (orig.)

  3. An algorithm for symplectic implicit Taylor-map tracking

    International Nuclear Information System (INIS)

    Yan, Y.; Channell, P.; Syphers, M.

    1992-10-01

    An algorithm has been developed for converting an ''order-by-order symplectic'' Taylor map that is truncated to an arbitrary order (thus not exactly symplectic) into a Courant-Snyder matrix and a symplectic implicit Taylor map for symplectic tracking. This algorithm is implemented using differential algebras, and it is numerically stable and fast. Thus, lifetime charged-particle tracking for large hadron colliders, such as the Superconducting Super Collider, is now made possible

  4. Building a wave energy policy focusing on innovation, manufacturing and deployment

    International Nuclear Information System (INIS)

    Dalton, G.; Gallachoir, B.P.O.

    2010-01-01

    The Irish Government has set a goal to make Ireland a world leader for research, development and deployment of ocean energy technologies. Ireland has a wave energy resource of 21 TWh and an ambition is to achieve at least 500 MW installed generating capacity from ocean energy by 2020. This paper investigates what is required to move from ambition to delivery. A successful wave energy strategy will require focused policies that will stimulate innovation to develop the technologies, manufacturing to produce the devices and deployment to build the required wave power plants. The paper draws on the successful policies in Ireland that have stimulated each of these dimensions, albeit for different sectors. From 2004 to 2008, successful policies in (ICT and biotech) innovation led to an increase in Ireland's Innovation Index score from 0.48 to 0.53. The policy focus on (food and pharmaceuticals) manufacturing in Ireland resulted in high levels of economic growth over the period 1998-2002, reaching >10% GDP growth levels per annum, and full employment. Successful wind energy policies deployment has accelerated rapidly since 2003 and reached 1.2 GW installed capacity in 2009 representing 15% of Ireland's total installed capacity. The paper draws on appropriate elements of these policies to build a successful wave energy policy for Ireland. It also draws on the successful policies adopted in Denmark for innovation, manufacturing and deployment of wind energy. The Danish wind turbine manufacturers hold a world market share of approximately 40%. The paper proposes establishing a wave energy strategy group to develop an action plan to deliver the 500 MW. It also proposes a novel extension of corporate tax specifically for wave energy companies, an initial 30% capital grant scheme for wave energy developers, a grid code for wave energy devices and fast tracking of planning decisions through an amended approach to strategic infrastructure. (author)

  5. A-Track: Detecting Moving Objects in FITS images

    Science.gov (United States)

    Atay, T.; Kaplan, M.; Kilic, Y.; Karapinar, N.

    2017-04-01

    A-Track is a fast, open-source, cross-platform pipeline for detecting moving objects (asteroids and comets) in sequential telescope images in FITS format. The moving objects are detected using a modified line detection algorithm.

  6. Development and Integration of the CT-PPS Fast Simulation in the CMS Software

    CERN Document Server

    Fonseca De Souza, Sandro

    2017-01-01

    CT-PPS (CMS-TOTEM Precision Proton Spectrometer) is a joint project of the CMS and TOTEM collaborations with the goal of studying central exclusive production (CEP) in proton-proton collisions. A simplified simulation and reconstruction code for CT-PPS has been implemented in the CMS fast simulation package FastSim. Protons scattered at very low polar angles are propagated along the LHC beamlines from the generated vertex to the detectors by means of the beam transport package Hector. The reconstructed proton tracks are obtained from the simulated hits in the tracking detectors and are used to determine the proton kinematics at the vertex. The timing information is added to the tracks.

  7. Thermal hydraulics of sodium-cooled fast reactors - key issues and highlights

    International Nuclear Information System (INIS)

    Ninokata, H.; Kamide, H.

    2011-01-01

    In this paper key issues and highlighted topics in thermal hydraulics are discussed in connection to the current Japan's sodium-cooled fast reactor development efforts. In particular, design study and related researches of the Japan Sodium-cooled Fast Reactor (JSFR) are focused. Several innovative technologies, e.g., compact reactor vessel, two-loop system, fully natural circulation decay heat removal, and recriticality free core, have been investigated in order to reduce construction cost and to achieve higher level of reactor safety. Preliminary evaluations of innovative technologies to be applied to JSFR are on-going. Here, progress of design study is introduced. Then, research and development activities on the thermal hydraulics related to the innovative technologies are briefly reviewed. (author)

  8. Simulator platform for fast reactor operation and safety technology demonstration

    International Nuclear Information System (INIS)

    Vilim, R.B.; Park, Y.S.; Grandy, C.; Belch, H.; Dworzanski, P.; Misterka, J.

    2012-01-01

    A simulator platform for visualization and demonstration of innovative concepts in fast reactor technology is described. The objective is to make more accessible the workings of fast reactor technology innovations and to do so in a human factors environment that uses state-of-the art visualization technologies. In this work the computer codes in use at Argonne National Laboratory (ANL) for the design of fast reactor systems are being integrated to run on this platform. This includes linking reactor systems codes with mechanical structures codes and using advanced graphics to depict the thermo-hydraulic-structure interactions that give rise to an inherently safe response to upsets. It also includes visualization of mechanical systems operation including advanced concepts that make use of robotics for operations, in-service inspection, and maintenance.

  9. Simulator platform for fast reactor operation and safety technology demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Vilim, R. B.; Park, Y. S.; Grandy, C.; Belch, H.; Dworzanski, P.; Misterka, J. (Nuclear Engineering Division)

    2012-07-30

    A simulator platform for visualization and demonstration of innovative concepts in fast reactor technology is described. The objective is to make more accessible the workings of fast reactor technology innovations and to do so in a human factors environment that uses state-of-the art visualization technologies. In this work the computer codes in use at Argonne National Laboratory (ANL) for the design of fast reactor systems are being integrated to run on this platform. This includes linking reactor systems codes with mechanical structures codes and using advanced graphics to depict the thermo-hydraulic-structure interactions that give rise to an inherently safe response to upsets. It also includes visualization of mechanical systems operation including advanced concepts that make use of robotics for operations, in-service inspection, and maintenance.

  10. A highly parallel algorithm for track finding

    International Nuclear Information System (INIS)

    Dell'Orso, M.

    1990-01-01

    We describe a very fast algorithm for track finding, which is applicable to a whole class of detectors like drift chambers, silicon microstrip detectors, etc. The algorithm uses a pattern bank stored in a large memory and organized into a tree structure. (orig.)

  11. RELATIONAL MECHANISMS IN INNOVATION CO-CREATION

    Directory of Open Access Journals (Sweden)

    Rodica Boier

    2014-12-01

    Full Text Available Increasingly, producers and customers establish relationships to mutually undertake the development of an innovative product. Consequently, it will be always of interest for an innovative company to know the degree to which different related suppliers are willing to form partnerships by participating in its new product development process. Several managerial implications flow from the link between relationship marketing and innovation processes, ranging from tactical product-related decisions to strategic competitor-related decisions, usually made in a relatively short period of time. Dedicated customer relationship systems track the interactions with customers and improve the flow of ideas for new products. When trying to develop long-term customer relationships, the ability to provide superior value to stakeholders is a must. Through carefully conducted relationships, customers are linked with the innovation company during the entire innovation process, and create a space for mutual understanding, learning and value co-creation. In order to co-create business value through online, also combined with offline innovation-related activities, customer orientation should be implemented throughout the organization – its culture, their systems, including the whole range of interactions.

  12. Initial Report of the Fast Timing Working Group

    CERN Document Server

    CMS Collaboration

    2016-01-01

    A preliminary set of results highlighting the unique capabilities of fast-timing for resolving information from individual collisions at the High-Luminosity LHC (HL- LHC) is presented. These results explore the possibilities made available by using fast timing to enhance the reconstruction and physics capabilities of the CMS detector in terms of pileup mitigation and searches for new physics. Fast timing applications in calorimetry, for electromagnetic showers, and for MIPs, to time-tag tracks, are demonstrated as are first examples of what is possible with their combination.

  13. Track recognition with an associative pattern memory

    International Nuclear Information System (INIS)

    Bok, H.W. den; Visschers, J.L.; Borgers, A.J.; Lourens, W.

    1991-01-01

    Using Programmable Gate Arrays (PGAs), a prototype for a fast Associative Pattern Memory module has been realized. The associative memory performs the recognition of tracks within the hadron detector data acquisition system at NIKHEF-K. The memory matches the detector state with a set of 24 predefined tracks to identify the particle tracks that occur during an event. This information enables the trigger hardware to classify and select or discriminate the event. Mounted on a standard size (6U) VME board, several PGAs together form an associative memory. The internal logic architecture of the Gate Array is used in such a way as to minimize signal propagation delay. The memory cells, containing a binary representation of the particle tracks, are dynamically loadable through a VME bus interface, providing a high level of flexibility. The hadron detector and its readout system are briefly described and our track representation method is presented. Results from measurements under experimental conditions are discussed. (orig.)

  14. Three-dimensional particle tracking velocimetry using dynamic vision sensors

    Science.gov (United States)

    Borer, D.; Delbruck, T.; Rösgen, T.

    2017-12-01

    A fast-flow visualization method is presented based on tracking neutrally buoyant soap bubbles with a set of neuromorphic cameras. The "dynamic vision sensors" register only the changes in brightness with very low latency, capturing fast processes at a low data rate. The data consist of a stream of asynchronous events, each encoding the corresponding pixel position, the time instant of the event and the sign of the change in logarithmic intensity. The work uses three such synchronized cameras to perform 3D particle tracking in a medium sized wind tunnel. The data analysis relies on Kalman filters to associate the asynchronous events with individual tracers and to reconstruct the three-dimensional path and velocity based on calibrated sensor information.

  15. FastSim: A Fast Simulation for the SuperB Detector

    International Nuclear Information System (INIS)

    Andreassen, R; Sokoloff, M; Arnaud, N; Burmistrov, L; Brown, D N; Carlson, J; Gaponenko, I; Suzuki, A; Cheng, C-h; Simone, A Di; Manoni, E; Perez, A; Walsh, J; Rama, M; Roberts, D; Rotondo, M; Simi, G

    2011-01-01

    We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.

  16. FastSim: A Fast Simulation for the SuperB Detector

    Science.gov (United States)

    Andreassen, R.; Arnaud, N.; Brown, D. N.; Burmistrov, L.; Carlson, J.; Cheng, C.-h.; Di Simone, A.; Gaponenko, I.; Manoni, E.; Perez, A.; Rama, M.; Roberts, D.; Rotondo, M.; Simi, G.; Sokoloff, M.; Suzuki, A.; Walsh, J.

    2011-12-01

    We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.

  17. Innovations in e-Business: Can Government Contracting be Adapted to Use Crowdsourcing and Open Innovation?

    Science.gov (United States)

    2010-09-01

    product standards and modular architecture benefit from wide market acceptance in commercial products.  Create a transparent and egalitarian ecosystem ... entrepreneurial spirit, such as Sylvester Stallone’s movie production Rocky, Microsoft’s founder Bill Gates and Oprah Winfrey, TV personality-commentator...innovative and entrepreneurial organizations that have a successful track record of taking technology out of the laboratory into a competitive market

  18. Integral fast reactor

    International Nuclear Information System (INIS)

    Chang, Y.I.

    1989-01-01

    The Integral Fast Reactor (IFR) is an innovative liquid metal reactor concept being developed at Argonne National Laboratory. It seeks to specifically exploit the inherent properties of liquid metal cooling and metallic fuel in a way that leads to substantial improvements in the characteristics of the complete reactor system. This paper describes the key features and potential advantages of the IFR concept, with emphasis on its safety characteristics

  19. Energy efficiency. A constant challenge to science and practice. Proceedings. 2. ed.; Energieeffizienz. Eine stete Herausforderung an Wissenschaft und Praxis. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Ulrich (ed.)

    2011-07-01

    Within the meeting ''Energy efficiency'' of the Research Center for Energy Economics (Munich, Federal Republic of Germany) from 12th to 13th May, 2011, at the Munich Residenz (Munich, Federal Republic of Germany) the following lectures were presented: (1) Innovation and research for an enhanced energy efficiency - New accents in the energy research politics of the Federal Government (Knut Kuebler); (2) Revolution of efficiency in the monastery St. Ottilien (Wolfgang Mauch); (3) From the maser plan to the local plan of energy utilization (Tobias Schmid); (4) The life cycle approach as a driver for innovative energy contracting (Alfred Gayer); (5) Energy efficiency networks (Anna Gruber); (6) Grid expansion for an enhanced utilization of renewable energies (Martin Fuchs); (7) Storage requirement in the electrical grid; (8) Scenarios for the development of the electromobility in Munich (Stephan Brunnert); (9) Li ion batteries for electrified automobiles - Demands and status (Peter Lamp); (10) Marketing of wind power (Serafin von Roon); (11) Demand side management in non-residential buildings (Johannes Jungwirth); (12) Energy future 2050 (Ulrich Wagner); (13) Decentral and renewable power generation (Ulli Arndt); (14) Electromobility - is that the future? (Markus Lienkamp); (14) Electric power - Reason or solution of the climate problem? (Harald Lesch).

  20. Energy efficiency. A constant challenge to science and practice. Proceedings. 2. ed.; Energieeffizienz. Eine stete Herausforderung an Wissenschaft und Praxis. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Ulrich [ed.

    2011-07-01

    Within the meeting ''Energy efficiency'' of the Research Center for Energy Economics (Munich, Federal Republic of Germany) from 12th to 13th May, 2011, at the Munich Residenz (Munich, Federal Republic of Germany) the following lectures were presented: (1) Innovation and research for an enhanced energy efficiency - New accents in the energy research politics of the Federal Government (Knut Kuebler); (2) Revolution of efficiency in the monastery St. Ottilien (Wolfgang Mauch); (3) From the maser plan to the local plan of energy utilization (Tobias Schmid); (4) The life cycle approach as a driver for innovative energy contracting (Alfred Gayer); (5) Energy efficiency networks (Anna Gruber); (6) Grid expansion for an enhanced utilization of renewable energies (Martin Fuchs); (7) Storage requirement in the electrical grid; (8) Scenarios for the development of the electromobility in Munich (Stephan Brunnert); (9) Li ion batteries for electrified automobiles - Demands and status (Peter Lamp); (10) Marketing of wind power (Serafin von Roon); (11) Demand side management in non-residential buildings (Johannes Jungwirth); (12) Energy future 2050 (Ulrich Wagner); (13) Decentral and renewable power generation (Ulli Arndt); (14) Electromobility - is that the future? (Markus Lienkamp); (14) Electric power - Reason or solution of the climate problem? (Harald Lesch).

  1. Solar tracking control tower; Steuerungstechnik folgt der Sonne

    Energy Technology Data Exchange (ETDEWEB)

    Leu, Andreas [Jetter AG, Ludwigsburg (Germany). Bereich technisches Marketing und Seminare

    2010-11-15

    The ''Gemue-Dome'' building at Waldzimmern is a unique industrial building. The research, development and innovation center has a rotary control tower equipped with solar cells which automatically tracks the sun. This automation task was a challenge for the control and power supply sections. (orig.)

  2. Possibilities of fast track surgery principles in the treatment of congenital urological anomalies

    Directory of Open Access Journals (Sweden)

    Bižić Marta R.

    2012-01-01

    Full Text Available Introduction. Urogenital congenital anomalies are among the most common congenital anomalies and very frequent pathology in paediatric urology. Health care systems strive to shorten the duration and reduce the costs of hospitalization, while maintaining treatment effectiveness. Objective. To evaluate the duration of hospital stay of surgically treated patients with congenital urogenital anomalies and estimate the possibility of using fast track surgery principles in paediatric urology in the local settings of a developing country. Methods. Retrospective non-randomized study included 552 patients who had been surgically treated at the Urology Department of the University Children’s Hospital, during 2010. In line with their congenital anomalies, all patients were classified in one of four groups: I - upper urinary tract anomalies (252 patients; II - genital anomalies (164 patients; III - testicular anomalies (76 patients and IV - associated anomalies (60 patients. We analyzed the total duration of stay as well as preand post-operative stay in the hospital. Results. The average duration of hospitalization was 4.7±4.0 days. Patients with testicular anomalies stayed for the shortest period (2.3±1.9 days (p<0.01 and patients with associated anomalies stayed in the hospital the longest (6.5±4.7 days (p<0.01. Conclusion. Modern methods of surgical treatment allow reduction of hospitalization, financial savings to the healthcare system and greater comfort for patients. Our results showed that this is also possible to apply in our environment.

  3. Donor Tracker: An Innovative Real-Time Tracking System for Blood ...

    African Journals Online (AJOL)

    In this paper, we explore the possibility of using location-aware computing to track blood donors in Mauritius and locate the nearest donor in cases of emergencies and whenever fresh blood is ... Keywords: Context-awareness, location-awareness, mobile and ubiquitous computing, location sensing technique, real-time.

  4. Networked innovations in guided tours

    DEFF Research Database (Denmark)

    Meged, Jane Widtfeldt; Zillinger, Malin

    This presentation is about a case study being done on networked innovation that is taking place within the scene of free guided tours in Copenhagen. Data has been collected on interactions between actors within the network of peers. In this way, both the own organisation and the actual market...... is being continually developed. ICT plays a key role, just as well as the relationships between the individual actors. It has been shown that close relationships building on friendship and trust are beneficial for the process of innovation. The fast growth of the sector of free guided tours however poses...

  5. Integral Fast Reactor concept

    Energy Technology Data Exchange (ETDEWEB)

    Till, C.E.; Chang, Y.I.

    1986-01-01

    The Integral Fast Reactor (IFR) is an innovative LMR concept, being developed at Argonne National Laboratory, that fully exploits the inherent properties of liquid metal cooling and metallic fuel to achieve breakthroughs in economics and inherent safety. This paper describes key features and potential advantages of the IFR concept, technology development status, fuel cycle economics potential, and future development path.

  6. Integral Fast Reactor concept

    International Nuclear Information System (INIS)

    Till, C.E.; Chang, Y.I.

    1986-01-01

    The Integral Fast Reactor (IFR) is an innovative LMR concept, being developed at Argonne National Laboratory, that fully exploits the inherent properties of liquid metal cooling and metallic fuel to achieve breakthroughs in economics and inherent safety. This paper describes key features and potential advantages of the IFR concept, technology development status, fuel cycle economics potential, and future development path

  7. Steam water cycle chemistry of liquid metal cooled innovative nuclear power reactors

    International Nuclear Information System (INIS)

    Yurmanov, Victor; Lemekhov, Vadim; Smykov, Vladimir

    2012-09-01

    The Federal Target Program (FTP) of Russian Federation 'Nuclear Energy Technologies of the New Generation for 2010-2015 and for Perspective up to 2020' is aimed at development of advanced nuclear energy technologies on the basis of closed fuel cycle with fast reactors. There are advanced fast reactor technologies of the 4. generation with liquid metal cooled reactors. Development stages of maturity of fast sodium cooled reactor technology in Russia includes experimental reactors BR-5/10 (1958-2002) and BOR-60 (since 1969), nuclear power plants (NPPs) with BN-350 (1972-1999), BN-600 (since 1980), BN-800 (under construction), BN-1200 (under development). Further stage of development of fast sodium cooled reactor technology in Russia is commercialization. Lead-bismuth eutectic fast reactor technology has been proven at industrial scale for nuclear submarines in former Soviet Union. Lead based technology is currently under development and need for experimental justification. Current status and prospects of State Corporation 'Rosatom' participation in GIF activities was clarified at the 31. Meeting of Policy Group of the International Forum 'Generation-IV', Moscow, May 12-13, 2011. In June, 2010, 'Rosatom' joined the Sodium Fast Reactor Arrangement as an authorized representative of the Russian Government. It was also announced the intention of 'Rosatom' to sign the Memorandum on Lead Fast Reactor based on Russia's experience with lead-bismuth and lead cooled fast reactors. In accordance with the above FTP some innovative liquid metal cooled reactors of different design are under development in Russia. Gidropress, well known as WER designer, develops innovative lead-bismuth eutectic cooled reactor SVBR-100. NIKIET develops innovative lead cooled reactor BRESTOD-300. Some other nuclear scientific centres are also involved in this activity, e.g. Research and Development Institute for Power Engineering (RDIPE). Optimum

  8. Transmission electron microscopy porometry of track membranes

    International Nuclear Information System (INIS)

    Reutov, V.F.; Dmitriev, S.N.; Sokhatskij, A.S.; Akap'ev, G.N.

    1998-01-01

    A fast method has been developed for the preparation of a sample appropriate for both SEM and TEM porometry of track membranes with pore channels of various geometric profiles and of size 10 nm and above. The method leads to the electrochemical deposition in the pore channels of a precipitate of monocrystalline copper directly on the surface of a copper foil disk bent into a spherical shape. The tight clamping of the track membrane on the disk surface is carried out by the creation of a vacuum in the space between them

  9. Towards Fast Tracking of the Keyhole Geometry

    Science.gov (United States)

    Brock, C.; Hohenstein, R.; Schmidt, M.

    We describe a sensor principle permitting the fast online measurement of the position of the optical process emissions in deep penetration laser welding. Experiments show a strong correlation between the position of the vapour plume and the keyhole geometry, demonstrated here by varying the penetration depth of the weld. In order to achieve an absolute position measurement, the sensor was calibrated using a light source with well defined characteristics. The setup for the calibration measurements and the corresponding data evaluation methods are discussed. The precision of the calibration with a green LED is 6 μm in lateral and 55 μm in axial direction, for a working distance of 200 mm.

  10. Technology on the Move: Recent and Forthcoming Innovations for Tracking Migratory Birds

    DEFF Research Database (Denmark)

    Bridge, Eli S.; Thorup, Kasper; Bowlin, Melissa S.

    2011-01-01

    networks, solar geolocation, radar, and information technology are improving our understanding of when and where birds go during their annual cycles and informing numerous scientific disciplines, including evolutionary biology, population ecology, and global change. The recent developments described......Basic questions about the life histories of migratory birds have confounded scientists for generations, yet we are nearing an era of historic discovery as new tracking technologies make it possible to determine the timing and routes of an increasing number of bird migrations. Tracking small flying...

  11. A Hardware Fast Tracker for the ATLAS trigger

    CERN Document Server

    Asbah, Nedaa; The ATLAS collaboration

    2015-01-01

    The trigger system of the ATLAS experiment is designed to reduce the event rate from the LHC nominal bunch crossing at 40 MHz to about 1 kHz, at the design luminosity of 10^{34} cm^{-2}s^{-1}. After a successful period of data taking from 2010 to early 2013, the LHC restarted with much higher instantaneous luminosity. This will increase the load on High Level Trigger system, the second stage of the selection based on software algorithms. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project; it is a hardware processor that will provide, at every level-1 accepted event (100 kHz) and within 100 microseconds, full tracking information for tracks with momentum as low as 1 GeV. Providing fast extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondar...

  12. ROMO - The Robotic Electric Vehicle

    OpenAIRE

    Brembeck, Jonathan; Ho, Lok Man; Schaub, Alexander; Satzger, Clemens; Tobolar, Jakub; Bals, Johann; Hirzinger, Gerhard

    2011-01-01

    This paper outlines the development of the ROboMObil, an innovative electro-mobility concept based on intelligent central control of four Wheel Robots, which integrate the drivetrain, brakes, steering and dampers. The motivation behind the Wheel Robot concept, the implementation details together with the suspension design are described. The electric power system, consisting of a Li-Ion battery cluster to provide high-voltage power for propulsion and a low-voltage supply for vehicle control, i...

  13. GEM detector performance with innovative micro-TPC readout in high magnetic field

    Directory of Open Access Journals (Sweden)

    Garzia I.

    2018-01-01

    Full Text Available Gas detector development is one of the pillars of the research in fundamental physics. Since several years, a new concept of detectors, called Micro Pattern Gas Detector (MPGD, allowed to overcome several problems related to other types of commonly used detectors, like drift chamber and micro strips detectors, reducing the rate of discharges and providing better radiation tolerance. Among the most used MPGDs are the Gas Electron Multipliers (GEMs. Invented by Sauli in 1997, nowadays GEMs have become an important reality for particle detectors in high energy physics. Commonly deployed as fast timing detectors and triggers, their fast response, high rate capability and high radiation hardness make them also suitable as tracking detectors. The readout scheme is one of the most important features in tracking technology. Analog readout based on the calculation of the center of gravity technique allows to overcome the limit imposed by digital pads, whose spatial resolution is limited by the pitch dimensions. However, the presence of high external magnetic fields can distort the electronic cloud and affect the performance. The development of the micro-TPC reconstruction method brings GEM detectors into a new prospective, improving significantly the spatial resolutionin presence of high magnetic fields. This innovative technique allows to reconstruct the 3-dimensional particle position, as Time Projection Chamber, but within a drift gap of a few millimeters. In these report, the charge centroid and micro-TPC methods are described in details. We discuss the results of several test beams performed with planar chambers in magnetic field. These results are one of the first developments of micro-TPC technique for GEM detectors, which allows to reach unprecedented performance in a high magnetic field of 1 T.

  14. GEM detector performance with innovative micro-TPC readout in high magnetic field

    Science.gov (United States)

    Garzia, I.; Alexeev, M.; Amoroso, A.; Baldini Ferroli, R.; Bertani, M.; Bettoni, D.; Bianchi, F.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Cassariti, V.; Cerioni, S.; Chai, J. Y.; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Dong, J.; Evangelisti, F.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Gatta, M.; Greco, M.; Lavezzi, L.; Leng, C. Y.; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Rolo, M. D.; Savrié, M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Verma, S.; Wheadon, R.; Yan, L.

    2018-01-01

    Gas detector development is one of the pillars of the research in fundamental physics. Since several years, a new concept of detectors, called Micro Pattern Gas Detector (MPGD), allowed to overcome several problems related to other types of commonly used detectors, like drift chamber and micro strips detectors, reducing the rate of discharges and providing better radiation tolerance. Among the most used MPGDs are the Gas Electron Multipliers (GEMs). Invented by Sauli in 1997, nowadays GEMs have become an important reality for particle detectors in high energy physics. Commonly deployed as fast timing detectors and triggers, their fast response, high rate capability and high radiation hardness make them also suitable as tracking detectors. The readout scheme is one of the most important features in tracking technology. Analog readout based on the calculation of the center of gravity technique allows to overcome the limit imposed by digital pads, whose spatial resolution is limited by the pitch dimensions. However, the presence of high external magnetic fields can distort the electronic cloud and affect the performance. The development of the micro-TPC reconstruction method brings GEM detectors into a new prospective, improving significantly the spatial resolutionin presence of high magnetic fields. This innovative technique allows to reconstruct the 3-dimensional particle position, as Time Projection Chamber, but within a drift gap of a few millimeters. In these report, the charge centroid and micro-TPC methods are described in details. We discuss the results of several test beams performed with planar chambers in magnetic field. These results are one of the first developments of micro-TPC technique for GEM detectors, which allows to reach unprecedented performance in a high magnetic field of 1 T.

  15. AUTOMATIC FAST VIDEO OBJECT DETECTION AND TRACKING ON VIDEO SURVEILLANCE SYSTEM

    Directory of Open Access Journals (Sweden)

    V. Arunachalam

    2012-08-01

    Full Text Available This paper describes the advance techniques for object detection and tracking in video. Most visual surveillance systems start with motion detection. Motion detection methods attempt to locate connected regions of pixels that represent the moving objects within the scene; different approaches include frame-to-frame difference, background subtraction and motion analysis. The motion detection can be achieved by Principle Component Analysis (PCA and then separate an objects from background using background subtraction. The detected object can be segmented. Segmentation consists of two schemes: one for spatial segmentation and the other for temporal segmentation. Tracking approach can be done in each frame of detected Object. Pixel label problem can be alleviated by the MAP (Maximum a Posteriori technique.

  16. Variation in ‘fast-track’ referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites

    Science.gov (United States)

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    Background: In England, ‘fast-track’ (also known as ‘two-week wait’) general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. Methods: We examined data from 669 220 patients with 35 cancers diagnosed in 2006–2010 following either fast-track or ‘routine’ primary-to-secondary care referrals using ‘Routes to Diagnosis’ data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. Results: There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Conclusions: Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for ‘alarm’ symptoms are needed to improve diagnostic timeliness. PMID:29182609

  17. Anesthesia and fast-track in video-assisted thoracic surgery (VATS): from evidence to practice.

    Science.gov (United States)

    Umari, Marzia; Falini, Stefano; Segat, Matteo; Zuliani, Michele; Crisman, Marco; Comuzzi, Lucia; Pagos, Francesco; Lovadina, Stefano; Lucangelo, Umberto

    2018-03-01

    In thoracic surgery, the introduction of video-assisted thoracoscopic techniques has allowed the development of fast-track protocols, with shorter hospital lengths of stay and improved outcomes. The perioperative management needs to be optimized accordingly, with the goal of reducing postoperative complications and speeding recovery times. Premedication performed in the operative room should be wisely administered because often linked to late discharge from the post-anesthesia care unit (PACU). Inhalatory anesthesia, when possible, should be preferred based on protective effects on postoperative lung inflammation. Deep neuromuscular blockade should be pursued and carefully monitored, and an appropriate reversal administered before extubation. Management of one-lung ventilation (OLV) needs to be optimized to prevent not only intraoperative hypoxemia but also postoperative acute lung injury (ALI): protective ventilation strategies are therefore to be implemented. Locoregional techniques should be favored over intravenous analgesia: the thoracic epidural, the paravertebral block (PVB), the intercostal nerve block (ICNB), and the serratus anterior plane block (SAPB) are thoroughly reviewed and the most common dosages are reported. Fluid therapy needs to be administered critically, to avoid both overload and cardiovascular compromisation. All these practices are analyzed singularly with the aid of the most recent evidences aimed at the best patient care. Finally, a few notes on some of the latest trends in research are presented, such as non-intubated video-assisted thoracoscopic surgery (VATS) and intravenous lidocaine.

  18. Recent innovation in microbial source tracking using bacterial real-time PCR markers in shellfish

    International Nuclear Information System (INIS)

    Mauffret, A.; Mieszkin, S.; Morizur, M.; Alfiansah, Y.; Lozach, S.; Gourmelon, M.

    2013-01-01

    Highlights: ► DNA extraction from intravalvular liquid is promising for microbial source tracking in oysters. ► Host-associated bacterial markers in shellfish digestive tissues were difficult to assess with real-time PCR. ► DNA extracts from shellfish flesh appeared to have low inhibitor levels but low marker levels. ► Protocol transfer from one shellfish species to another does not appear possible. -- Abstract: We assessed the capacity of real-time PCR markers to identify the origin of contamination in shellfish. Oyster, cockles or clams were either contaminated with fecal materials and host-associated markers designed from Bacteroidales or Catellicoccus marimammalium 16S RNA genes were extracted from their intravalvular liquid, digestive tissues or shellfish flesh. Extraction of bacterial DNA from the oyster intravalvular liquid with FastDNA spin kit for soil enabled the selected markers to be quantified in 100% of artificially contaminated samples, and the source of contamination to be identified in 13 out of 38 naturally contaminated batches from European Class B and Class C areas. However, this protocol did not enable the origin of the contamination to be identified in cockle or clam samples. Although results are promising for extracts from intravalvular liquid in oyster, it is unlikely that a single protocol could be the best across all bacterial markers and types of shellfish

  19. Stem Cell Tracking Technologies for Neurological Regenerative Medicine Purposes

    Directory of Open Access Journals (Sweden)

    Yongtao Zheng

    2017-01-01

    Full Text Available The growing field of stem cell therapy is moving toward clinical trials in a variety of applications, particularly for neurological diseases. However, this translation of cell therapies into humans has prompted a need to create innovative and breakthrough methods for stem cell tracing, to explore the migration routes and its reciprocity with microenvironment targets in the body, to monitor and track the outcome after stem cell transplantation therapy, and to track the distribution and cell viability of transplanted cells noninvasively and longitudinally. Recently, a larger number of cell tracking methods in vivo were developed and applied in animals and humans, including magnetic resonance imaging, nuclear medicine imaging, and optical imaging. This review has been intended to summarize the current use of those imaging tools in tracking stem cells, detailing their main features and drawbacks, including image resolution, tissue penetrating depth, and biosafety aspects. Finally, we address that multimodality imaging method will be a more potential tracking tool in the future clinical application.

  20. Proposed FPGA based tracking for a Level-1 track trigger at CMS for the HL-LHC

    CERN Document Server

    Pozzobon, Nicola

    2014-01-01

    The High Luminosity LHC (HL-LHC) is expected to deliver a luminosity in excess of $5\\times10^{34}$ cm$^{-2}$/s. The high event rate places stringent requirements on the trigger system. A key component of the CMS upgrade for the HL-LHC is a track trigger system which will identify tracks with transverse momenta above 2 GeV already at the first-level trigger within 5 $\\mu$s. This presentation will discuss a proposed track finding and fitting based on the tracklet based approach implemented on FPGAs. Tracklets are formed from pairs of hits in nearby layers in the detector and used in a road search. Summary Fast pattern recognition in Silicon trackers for triggering has often made use of Associative Memories for the pattern recognition step. We propose an alternative approach to solving the pattern recognition and track fitting problem for the upgraded CMS tracker for the HL-LHC operation. We make use of the trigger primitives,stubs, from the tracker. The stubs are formed from pairs of hits in sensors separated r...