WorldWideScience

Sample records for electrochemical noise measurement

  1. Electrochemical corrosion potential and noise measurement in high temperature water

    International Nuclear Information System (INIS)

    Fong, Clinton; Chen, Yaw-Ming; Chu, Fang; Huang, Chia-Shen

    2000-01-01

    Hydrogen water chemistry (HWC) is one of the most important methods in boiling water reactor(BWR) system to mitigate and prevent stress corrosion cracking (SCC) problems of stainless steel components. Currently, the effectiveness of HWC in each BWR is mainly evaluated by the measurement of electrochemical corrosion potentials (ECP) and on-line monitoring of SCC behaviors of stainless steels. The objective of this work was to evaluate the characteristics and performance of commercially available high temperature reference electrodes. In addition, SCC monitoring technique based on electrochemical noise analysis (ECN) was also tested to examine its crack detection capability. The experimental work on electrochemical corrosion potential (ECP) measurements reveals that high temperature external Ag/AgCl reference electrode of highly dilute KCl electrolyte can adequately function in both NWC and HWC environments. The high dilution external Ag/AgCl electrode can work in conjunction with internal Ag/AgCl reference electrode, and Pt electrode to ensure the ECP measurement reliability. In simulated BWR environment, the electrochemical noise tests of SCC were carried out with both actively and passively loaded specimens of type 304 stainless steel with various electrode arrangements. From the coupling current and corrosion potential behaviors of the passive loading tests during immersion test, it is difficult to interpret the general state of stress corrosion cracking based on the analytical results of overall current and potential variations, local pulse patterns, statistical characteristics, or power spectral density of electrochemical noise signals. However, more positive SCC indication was observed in the power spectral density analysis. For aqueous environments of high solution impedance, successful application of electrochemical noise technique for SCC monitoring may require further improvement in specimen designs and analytical methods to enhance detection sensitivity

  2. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  3. Corrosion monitoring of the AA2024 alloy in NaCl solutions by electrochemical noise measurements

    International Nuclear Information System (INIS)

    Aballe, A.; Bethencourt, M.; Botana, F.J.; Marcos, M.; Rodriguez-Chacon, M.A.

    1998-01-01

    The behaviour of the AA2024 alloy against corrosion in 3.5% NaCl solution has been monitored. In this environment the alloy can be easily damaged under small anodic polarizations. Linear Polarization, electrochemical impedance, spectroscopy and electrochemical noise measurement have been used as experimental techniques. Data from ENM have been analyzed using statistical parameters and Chaos Theory. The results here obtained suggest that ENM is particularly useful to monitored systems that can be modified using other electrochemical techniques. (Author) 11 refs

  4. Electrochemical noise from corroding carbon steel and aluminium

    International Nuclear Information System (INIS)

    Singh, P.R.; Gaonkar, K.B.; De, P.K.; Banerjee, S.

    1997-05-01

    Electrochemical noise measurements were conducted on carbon steel and aluminium in sodium chloride solutions. Noise parameters like standard deviation of potential and current, noise resistance, pitting index, noise power were studied for the purpose of measuring corrosion rate. These parameters compared well with the corrosion rate. Pitting index was not very reliable. Current noise was more close to the corrosion rates. General corrosion gave rise to white noise type of power spectrum while flicker noise type of spectrum was obtained from pitting attack. Sodium nitrite is shown to inhibit the corrosion of carbon steel. Aluminium corrodes in the early period of exposure and passivates during long exposure

  5. Electrochemical noise measurements of steel corrosion in the molten NaCl-K2SO4 system

    DEFF Research Database (Denmark)

    Cappeln, Frederik Vilhelm; Bjerrum, Niels; Petrushina, Irina

    2005-01-01

    -called active corrosion (i.e., the corrosion proceeds with no passivation due to the influence of chlorine), characterized by the formation of volatile metal chlorides as a primary corrosion product. It was found possible to obtain an empirical separation of general and intergranular corrosion using kurtosis (a......Electrochemical noise measurements have been carried out on AISI347, 10CrMo910, 15Mo3, and X20CrMoV121 steels in molten NaCl-K2SO4 at 630 degrees C. Different types of current noise have been identified for pitting, intergranular and peeling corrosion. The corrosion mechanism was the so...... statistical parameter calculated from the electrochemical noise data). It was found that average kurtosis values above 6 indicated intergranular corrosion and average values below 6 indicated general corrosion. The response time for localized corrosion detection in in-plant monitoring was approximately 90 min...

  6. Corrosion monitoring in a straw-fired power plant using an electrochemical noise probe

    DEFF Research Database (Denmark)

    Cappeln, Frederik Vilhelm; Bjerrum, Niels; Petrushina, Irina

    2007-01-01

    Electrochemical Noise Measurements have been carried out in situ in a straw-fired power plant using an experimental probe constructed from alumina and AlSl 347 steel. Based on a framework of controlled laboratory experiments it has been found that electrochemical noise has the unique ability...... to provide in-situ monitoring of intergranular corrosion in progress. The probe had a lifetime of two months. It was shown that down-time corrosion in the boiler was negligible. Electrochemical noise data indicated that metal temperatures around 590 degrees C should be avoided as the intergranular corrosion...

  7. Electrochemical noise measurements techniques and the reversing dc potential drop method applied to stress corrosion essays

    International Nuclear Information System (INIS)

    Aly, Omar Fernandes; Andrade, Arnaldo Paes de; MattarNeto, Miguel; Aoki, Idalina Vieira

    2002-01-01

    This paper aims to collect information and to discuss the electrochemical noise measurements and the reversing dc potential drop method, applied to stress corrosion essays that can be used to evaluate the nucleation and the increase of stress corrosion cracking in Alloy 600 and/or Alloy 182 specimens from Angra I Nuclear Power Plant. Therefore we will pretend to establish a standard procedure to essays to be realized on the new autoclave equipment on the Laboratorio de Eletroquimica e Corrosao do Departamento de Engenharia Quimica da Escola Politecnica da Universidade de Sao Paulo - Electrochemical and Corrosion Laboratory of the Chemical Engineering Department of Polytechnical School of Sao Paulo University, Brazil. (author)

  8. Modeling of pH Dependent Electrochemical Noise in Ion Sensitive Field Effect Transistors ISFET

    Directory of Open Access Journals (Sweden)

    M. P. Das

    2013-02-01

    Full Text Available pH ISFETs are very important sensor for in vivo continuous monitoring application of physiological and environmental system. The accuracy of Ion Sensitive Field Effect Transistor (ISFET output measurement is greatly affected by the presences of noise, drift and slow response of the device. Although the noise analysis of ISFET so far performed in different literature relates only to sources originated from Field Effect Transistor (FET structure which are almost constant for a particular device, the pH dependent electrochemical noise has not been substantially explored and analyzed. In this paper we have investigated the low frequency pH dependent electrochemical noise that originates from the ionic conductance of the electrode-electrolyte-Field Effect Transistor structure of the device and that the noise depends on the concentration of the electrolyte and 1/f in nature. The statistical and frequency analysis of this electrochemical noise of a commercial ISFET sensor, under room temperature has been performed for six different pH values ranging from pH2 to pH9.2. We have also proposed a concentration dependent a/f & b/f2 model of the noise with different values of the coefficients a, b.

  9. A study of passivation/depassivation of carbon steel; electrochemical impedance spectrocopy vs. potential noise fluctuations

    International Nuclear Information System (INIS)

    Roberge, P.R.; Halliop, E.; Sastri, V.S.

    1992-01-01

    A technique based on recording corrosion potential fluctuations generated by corroding electrodes was used under open-circuit conditions to study passivation and depassivation of carbon steel. Quantification of the electrochemical signal in terms of the pitting corrosion rate has been attempted. The amplitude of electrochemical noise signals was analyzed under different pitting conditions and correlated to polarization resistance values obtained from the electrochemical impedance spectra. The automatic statistical data analysis of electrochemical impedance data points has been successfully applied to calculate polarization resistance values and other interesting characteristics of such measurements

  10. Application of a passive electrochemical noise technique to localized corrosion of candidate radioactive waste container materials

    International Nuclear Information System (INIS)

    Korzan, M.A.

    1994-05-01

    One of the key engineered barriers in the design of the proposed Yucca Mountain repository is the waste canister that encapsulates the spent fuel elements. Current candidate metals for the canisters to be emplaced at Yucca Mountain include cast iron, carbon steel, Incoloy 825 and titanium code-12. This project was designed to evaluate passive electrochemical noise techniques for measuring pitting and corrosion characteristics of candidate materials under prototypical repository conditions. Experimental techniques were also developed and optimized for measurements in a radiation environment. These techniques provide a new method for understanding material response to environmental effects (i.e., gamma radiation, temperature, solution chemistry) through the measurement of electrochemical noise generated during the corrosion of the metal surface. In addition, because of the passive nature of the measurement the technique could offer a means of in-situ monitoring of barrier performance

  11. Measurement of electrochemical noise for the study of corrosion processes of metallic alloys; Medida de ruido electroquimico para el estudio de rocesoso de corrosion de aleaciones metalicas

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Amaya, J. M.; Bethencourt, M.; Gonzalez-Rovira, L.; Botana, F. J.

    2009-07-01

    Electrochemical noise (EN) is a technique that allows the estimation of both the rate and the corrosion mechanism of different metallic alloys by means of the measurement and the analysis of the fluctuations of current and voltage. Its main advantage against other electrochemical techniques is that during the measurement process, the corrosive systems under study are not instrumentally disturbed, and therefore, the systems are kept at their natural corrosion potential. Two steps are necessary to use this technique: measurement and analysis of the EN signals. In this paper, the most important concepts related only to the measurement of EN are revised. The parameters most employed in the literature to analyse the EN signals will be described in another paper. In the present article, the experimental devices normally used to measure EN signals are firstly analysed. Subsequently, the most important properties of the EN signals are studied. Finally, the external sources of instrumental noise that can affect to the EN signals are described. (Author) 65 refs.

  12. Advantages of Wavelet analysis compared to Fourier analysis for the interpretation of electrochemical noise

    International Nuclear Information System (INIS)

    Espada, L.; Sanjurjo, M.; Urrejola, S.; Bouzada, F.; Rey, G.; Sanchez, A.

    2003-01-01

    Given its simplicity and low cost compared to other types of methodologies, the measurement and interpretation of Electrochemical Noise, is consolidating itself as one of the analysis methods most frequently used for the interpretation of corrosion. As the technique is still evolving, standard treatment methodologies for data retrieved in experiments do not exist yet. To date, statistical analysis and the Fourier analysis are commonly used in order to establish the parameters that may characterize the recording of potential and current electrochemical noise. This study introduces a new methodology based on wavelet analysis and presents its advantages with regards to the Fourier analysis in distinguishes periodical and non-periodical variations in the signal power in time and frequency, as opposed to the Fourier analysis that only considers the frequency. (Author) 15 refs

  13. Application of spectral analysis of the electrochemical noise to the investigation of aluminium alloy pitting corrosion

    International Nuclear Information System (INIS)

    Bataillon, Christian

    1987-01-01

    The objective of this research is to decode (at least partially) the nature of the information contained in the electrochemical noise associated with the pitting corrosion phenomenon in aluminium alloys. After a general presentation of aluminium and its alloys and a report of a bibliographical study on the electrochemical noise, the author gives an overview of a theoretical approach of stochastic phenomena, and of an experimental approach. Then, the experimental investigation of the electrochemical noise in the case of pitting corrosion leads to a noise control law, to a study of the structure of pitting growth, and to the elaboration of a procedure of assessment of spectral characteristics of this noise. The author reports a systematic study of the electrochemical noise with respect to the parameters of the control law. Results allow a quantitative characterization of pitting corrosion resistance of the studied alloys, notably by using the kinetic aspect of pitting growth and the structure of pitting corrosion. The author discusses the physicochemical nature of random fluctuations which build up the noise. He proposes a more precise explanation of phenomena related to initiation and propagation of pitting corrosion on aluminium alloys in marine environment [fr

  14. Destructive impact of molecular noise on nanoscale electrochemical oscillators

    Science.gov (United States)

    Cosi, Filippo G.; Krischer, Katharina

    2017-06-01

    We study the loss of coherence of electrochemical oscillations on meso- and nanosized electrodes with numeric simulations of the electrochemical master equation for a prototypical electrochemical oscillator, the hydrogen peroxide reduction on Pt electrodes in the presence of halides. On nanoelectrodes, the electrode potential changes whenever a stochastic electron-transfer event takes place. Electrochemical reaction rate coefficients depend exponentially on the electrode potential and become thus fluctuating quantities as well. Therefore, also the transition rates between system states become time-dependent which constitutes a fundamental difference to purely chemical nanoscale oscillators. Three implications are demonstrated: (a) oscillations and steady states shift in phase space with decreasing system size, thereby also decreasing considerably the oscillating parameter regions; (b) the minimal number of molecules necessary to support correlated oscillations is more than 10 times as large as for nanoscale chemical oscillators; (c) the relation between correlation time and variance of the period of the oscillations predicted for chemical oscillators in the weak noise limit is only fulfilled in a very restricted parameter range for the electrochemical nano-oscillator.

  15. The use of skewness, kurtosis and neural networks for determining corrosion mechanism from electrochemical noise data

    International Nuclear Information System (INIS)

    Reid, S.; Bell, G.E.C.; Edgemon, G.L.

    1998-01-01

    This paper describes the work undertaken to de-skill the complex procedure of determining corrosion mechanisms derived from electrochemical noise data. The use of neural networks is discussed and applied to the real time generated electrochemical noise data files with the purpose of determining characteristics particular to individual types of corrosion mechanisms. The electrochemical noise signals can have a wide dynamic range and various methods of raw data pre-processing prior to neural network analysis were investigated. Normalized data were ultimately used as input to the final network analysis. Various network schemes were designed, trained and tested. Factors such as the network learning schedule and network design were considered before a final network was implemented to achieve a solution. Neural networks trained using general and localized corrosion data from various material environment systems were used to analyze data from simulated nuclear waste tank environments with favorable results

  16. Managing Electrochemical Noise Data by Exception Application of an On Line EN Data Analysis Technique to Data From a High Level Nuclear Waste Tank

    International Nuclear Information System (INIS)

    EDGEMON, G.L.

    2003-01-01

    Electrochemical noise has been used a t the Hanford Site for a number of years to monitor in real time for pitting corrosion and stress corrosion cracking (SCC) mechanisms in high level nuclear waste tanks. Currently the monitoring technique has only been implemented on three of the 177 underground storage tanks on the site. Widespread implementation of the technique has been held back for of a number of reasons, including issues around managing the large volume of data associated with electrochemical noise and the complexity of data analysis. Expert review of raw current and potential measurements is the primary form of data analysis currently used at the Hanford site. This paper demonstrates the application of an on-line data filtering and analysis technique that could allow data from field applications of electrochemical noise to be managed by exception, transforming electrochemical noise data into a process parameter and focusing data analysis efforts on the important data. Results of the analysis demonstrate a data compression rate of 95%; that is, only 5% of the data would require expert analysis if such a technique were implemented. It is also demonstrated that this technique is capable of identifying key periods where localized corrosion activity is apparent

  17. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  18. Electrochemical noise and impedance of Au electrode/electrolyte interfaces enabling extracellular detection of glioma cell populations.

    Science.gov (United States)

    Rocha, Paulo R F; Schlett, Paul; Kintzel, Ulrike; Mailänder, Volker; Vandamme, Lode K J; Zeck, Gunther; Gomes, Henrique L; Biscarini, Fabio; de Leeuw, Dago M

    2016-10-06

    Microelectrode arrays (MEA) record extracellular local field potentials of cells adhered to the electrodes. A disadvantage is the limited signal-to-noise ratio. The state-of-the-art background noise level is about 10 μVpp. Furthermore, in MEAs low frequency events are filtered out. Here, we quantitatively analyze Au electrode/electrolyte interfaces with impedance spectroscopy and noise measurements. The equivalent circuit is the charge transfer resistance in parallel with a constant phase element that describes the double layer capacitance, in series with a spreading resistance. This equivalent circuit leads to a Maxwell-Wagner relaxation frequency, the value of which is determined as a function of electrode area and molarity of an aqueous KCl electrolyte solution. The electrochemical voltage and current noise is measured as a function of electrode area and frequency and follow unambiguously from the measured impedance. By using large area electrodes the noise floor can be as low as 0.3 μVpp. The resulting high sensitivity is demonstrated by the extracellular detection of C6 glioma cell populations. Their minute electrical activity can be clearly detected at a frequency below about 10 Hz, which shows that the methodology can be used to monitor slow cooperative biological signals in cell populations.

  19. Corrosion detection of carbon steel in water/oil two phases environment by electrochemical noise analysis

    International Nuclear Information System (INIS)

    Gusmano, G.; Montesperelli, G.; De Grandis, A.

    1998-01-01

    The aim of this paper is to demonstrate the effectiveness of the electrochemical noise analysis to detect the onset of corrosion phenomena in a very high resistivity medium. Tests were carried out on carbon steel electrodes immersed in a water/mineral oil two phases environment with high concentration of CO 2 , different aqueous/organic phase ratio, sulphide content between 0 and 0.5 g/l and pH between 1 and 5. The evolution of corrosion phenomena were followed by collecting current and potential noise between three nominally identical electrodes. The noise data were analysed in the time and in the frequency domain. In spite of a great loss of sensitivity of the method with respect to tests performed in aqueous solution, the data indicate a good agreement between the standard deviations and the power level of power spectra density (PSD) of current and potential noise signals and corrosion rates by means of weight loss. The values of the PSD slope, indicate the form of corrosion. The effect of water/oil ratio, sulphide concentration and pH on the corrosion rate was determined. Finally two methods to increase the sensitivity of the electrochemical noise are proposed. (orig.)

  20. A state of the art on electrochemical noise technique. Assessment of corrosion characteristics and development of remedial technology in nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jin; Kim, Joung Soo; Kim, Hong Pyo; Lim, Yun Soo; Yi, Yong Sun; Chung, Man Kyo

    2003-02-01

    The studies for the application of electrochemical noise technique were reviewed in terms of principle, analysing method and application examples of this technique. Because 4% of the economic damage of industry is caused by metallic corrosion, it is important to find and protect corrosive materials and location. By corrosion monitoring of industrial facilities such as nuclear power plant using Electrochemical Noise Measurement(ENM), corrosion attack can be detected and furthermore it can be indicated whether the attacked materials is replaced by new one or not. According to development of control and electronic technology, it was easy to apply ENM to the industry and the interest in ENM also increased. As corrosion is produced on a metal under corrosive environment, local anode(oxidation) and cathode(reduction) are formed. Hence, there is potential difference and current flow between the anode and cathode. ENM is monitoring the potential difference and the current flow with time by high impedance load voltmeter and Zero Resistance Ammeter(ZRA), respectively. The potential difference and current flow generated spontaneously without any application of current and potential between electrodes are monitored by electrochemical noise technique, Thereby ENM can be regarded as the most ideal corrosion monitoring method for the industrial facility and nuclear power plant having corrosion damage and difficulty in access of human body. Moreover, it is possible to obtain the spontaneous and reliable results from the metals damaged by ununiform and localized corrosion such as pitting and SCC using ENM while it is difficult to obtain the reliable result using traditional linear polarization and ac-impedance measurement. In many countries, there are extensive works concerned with application of electrochemical noise technique to corrosion monitoring of nuclear power plant and other industrial facilities, whereas there is little work on this field in Korea. Systematic study for

  1. In situ characterization of natural pyrite bioleaching using electrochemical noise technique

    Science.gov (United States)

    Chen, Guo-bao; Yang, Hong-ying; Li, Hai-jun

    2016-02-01

    An in situ characterization technique called electrochemical noise (ECN) was used to investigate the bioleaching of natural pyrite. ECN experiments were conducted in four active systems (sulfuric acid, ferric-ion, 9k culture medium, and bioleaching solutions). The ECN data were analyzed in both the time and frequency domains. Spectral noise impedance spectra obtained from power spectral density (PSD) plots for different systems were compared. A reaction mechanism was also proposed on the basis of the experimental data analysis. The bioleaching system exhibits the lowest noise resistance of 0.101 MΩ. The bioleaching of natural pyrite is considered to be a bio-battery reaction, which distinguishes it from chemical oxidation reactions in ferric-ion and culture-medium (9k) solutions. The corrosion of pyrite becomes more severe over time after the long-term testing of bioleaching.

  2. Problems, pitfalls, and probes: Welcome to the jungle of electrochemical noise technology

    International Nuclear Information System (INIS)

    Edgemon, G.L.

    1998-01-01

    The rise in electrochemical noise (EN) as a corrosion monitoring technique has resulted in unique problems associated with the field application of this method. Many issues relate to the design of the EN probe electrodes. The ability of an electrochemical noise monitoring system to identify and discriminate between localized corrosion mechanisms is related primarily to the capability of the probe to separate the corrosion cell anode from the corresponding cathode. Effectiveness of this separation is largely determined by the details of and the proper design of the probe that is in the environment of interest. No single probe design or geometry can be effectively use in every situation to monitor all types of corrosion. In this paper the authors focus on a case study and probe development history related to monitoring corrosion in an extremely hostile environment using EN. While the ultimate application of EN was and continues to be successful, the case study shows that patience and persistence was necessary to meet and properly implement the monitoring program. Other possible source of problems and frustration with implementing EN are also discussed

  3. Note: A temperature-stable low-noise transimpedance amplifier for microcurrent measurement

    Science.gov (United States)

    Xie, Kai; Shi, Xueyou; Zhao, Kai; Guo, Lixin; Zhang, Hanlu

    2017-02-01

    Temperature stability and noise characteristics often run contradictory in microcurrent (e.g., pA-scale) measurement instruments because low-noise performance requires high-value resistors with relatively poor temperature coefficients. A low-noise transimpedance amplifier with high-temperature stability, which involves an active compensation mechanism to overcome the temperature drift mainly caused by high-value resistors, is presented. The implementation uses a specially designed R-2R compensating network to provide programmable current gain with extra-fine trimming resolution. The temperature drifts of all components (e.g., feedback resistors, operational amplifiers, and the R-2R network itself) are compensated simultaneously. Therefore, both low-temperature drift and ultra-low-noise performance can be achieved. With a current gain of 1011 V/A, the internal current noise density was about 0.4 fA/√Hz, and the average temperature coefficient was 4.3 ppm/K at 0-50 °C. The amplifier module maintains accuracy across a wide temperature range without additional thermal stabilization, and its compact size makes it especially suitable for high-precision, low-current measurement in outdoor environments for applications such as electrochemical emission supervision, air pollution particles analysis, radiation monitoring, and bioelectricity.

  4. Electrochemical noise evaluation of anodized aluminum. Comparative study against corrosion behaviour in the atmosphere

    International Nuclear Information System (INIS)

    Betancourt, N.; Corvo, F.; Mendoza, A.; Simancas, J.; Morcillo, M.; Gonzalez, J. A.; Fragata, F.; Pena, J. J.; Sanchez de Villalaz, M.; Flores, S.; Almeida, E.; Rivero, S.; Rincon, O. T. de.

    2003-01-01

    The present work reports the evaluation of aluminum and anodized aluminum by electrochemical noise, as a part of the PATINE/CYTED project of the working group NS5. A visual examination is also made. The samples were exposed at several Ibero-American atmospheres up to 2 years of exposure. Different thickness of anodized aluminum were evaluated. The electrochemical potential noise of the 5 μm unexposed sample (pattern) showed a different behaviour to that showed by the other anodized specimens. This could be due to a slower sealed of the samples of higher thickness. The same behavior was observed on the samples exposed at the rural station. el Pardo. According to the visual examination, the samples of bare aluminum and those of anodized 5 μm thickness were the most affected by pitting corrosion in the highly polluted atmospheres. A good correlation between corrosion behaviour determined by visual examination and EN was obtained. (Author) 4 refs

  5. Corrosion resistance test based on electrochemical noise-limiting the number of long-lasting and costly climate chamber tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Veldman, D.; Gouwen, R.J.; Bende, E.E.; Eerenstein, W.

    2013-10-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. The electrochemical noise (EcN) set-up is a fast, direct corrosion measurement of solar cells, whereby results can be obtained within one hour. EcN measurements are presented for several solar cell concepts and different environments. It correlates with damp-heat degradation involving corrosion, which is rather common in EVA-encapsulated crystalline Si modules. Furthermore, the EcN test can be done as an evaluation tool when probing alternative brands, formulations or processing for metallisation pastes and as a screening test for new batches of metallisation paste.

  6. Comparison of susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys in neutral chloride solutions using electrochemical noise analysis

    International Nuclear Information System (INIS)

    Na, Kyung-Hwan; Pyun, Su-Il

    2008-01-01

    The susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys was investigated in aqueous neutral chloride solution for the purpose of comparison using electrochemical noise measurement. The experimentally measured electrochemical noises were analysed based upon the combined stochastic theory and shot-noise theory using the Weibull distribution function. From the occurrence of two linear regions on one Weibull probability plot, it was suggested that there existed two stochastic processes of uniform corrosion and pitting corrosion; pitting corrosion was distinguished from uniform corrosion in terms of the frequency of events in the stochastic analysis. Accordingly, the present analysis method allowed us to investigate pitting corrosion independently. The susceptibility to pitting corrosion was appropriately evaluated by determining pit embryo formation rate in the stochastic analysis. The susceptibility was decreased in the following order: AA2024-T4 (the naturally aged condition), AA7475-T761 (the overaged condition) and AA7075-T651 (the near-peak-aged condition)

  7. Measurement of Noise in Supercapacitors

    OpenAIRE

    Szewczyk Arkadiusz

    2017-01-01

    A developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.

  8. Measurement of Noise in Supercapacitors

    Directory of Open Access Journals (Sweden)

    Szewczyk Arkadiusz

    2017-12-01

    Full Text Available A developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.

  9. Electrochemical Noise Chaotic Analysis of NiCoAg Alloy in Hank Solution

    Directory of Open Access Journals (Sweden)

    D. Bahena

    2011-01-01

    Full Text Available The potential and current oscillations during corrosion of NiCoAg alloy in Hank solution were studied. Detailed nonlinear fractal analyses were used to characterize complex time series clearly showing that the irregularity in these time series corresponds to deterministic chaos rather than to random noise. The chaotic oscillations were characterized by power spectral densities, phase space, and Lyapunov exponents. Electrochemical impedance was also applied the fractal dimensions for the corroded surface was obtained, and a corrosion mechanism was proposed.

  10. A Plan to Develop and Demonstrate Electrochemical Noise Based Corrosion Monitoring Systems in Hanford Site Waste Tanks

    International Nuclear Information System (INIS)

    NORMAN, E.C.

    2000-01-01

    This document describes changes that need to be made to the site's authorization basis and technical concerns that need to be resolved before proceduralized use of Electrochemical Noise based corrosion monitoring systems is fully possible at the Hanford Site

  11. Electrochemical noise based corrosion monitoring: FY 2001 final report

    International Nuclear Information System (INIS)

    EDGAR, C.

    2001-01-01

    Underground storage tanks made of mild steel are used to contain radioactive waste generated by plutonium production at the Hanford Site. Corrosion of the walls of these tanks is a major issue. Corrosion monitoring and control are currently provided at the Hanford Site through a waste chemistry sampling and analysis program. In this process, tank waste is sampled, analyzed and compared to a selection of laboratory exposures of coupons in simulated waste. Tank wall corrosion is inferred by matching measured tank chemistries to the results of the laboratory simulant testing. This method is expensive, time consuming, and does not yield real-time data. Corrosion can be monitored through coupon exposure studies and a variety of electrochemical techniques. A small number of these techniques have been tried at Hanford and elsewhere within the DOE complex to determine the corrosivity of nuclear waste stored in underground tanks [1]. Coupon exposure programs, linear polarization resistance (LPR), and electrical resistance techniques have all been tried with limited degrees of success. These techniques are most effective for monitoring uniform corrosion, but are not well suited for early detection of localized forms of corrosion such as pitting and stress corrosion cracking (SCC). Pitting and SCC have been identified as the most likely modes of corrosion failure for Hanford Double Shell Tanks (DST'S) [2-3]. Over the last 20 years, a new corrosion monitoring system has shown promise in detecting localized corrosion and measuring uniform corrosion rates in process industries [4-20]. The system measures electrochemical noise (EN) generated by corrosion. The term EN is used to describe low frequency fluctuations in current and voltage associated with corrosion. In their most basic form, EN-based corrosion monitoring systems monitor and record fluctuations in current and voltage over time from electrodes immersed in an environment of interest. Laboratory studies and field

  12. Analysis of electrochemical noise (ECN) data in time and frequency domain for comparison corrosion inhibition of some azole compounds on Cu in 1.0 M H2SO4 solution

    Science.gov (United States)

    Ramezanzadeh, B.; Arman, S. Y.; Mehdipour, M.; Markhali, B. P.

    2014-01-01

    In this study, the corrosion inhibition properties of two similar heterocyclic compounds namely benzotriazole (BTA) and benzothiazole (BNS) inhibitors on copper in 1.0 M H2SO4 solution were studied by electrochemical techniques as well as surface analysis. The results showed that corrosion inhibition of copper largely depends on the molecular structure and concentration of the inhibitors. The effect of DC trend on the interpretation of electrochemical noise (ECN) results in time domain was evaluated by moving average removal (MAR) method. Accordingly, the impact of square and Hanning window functions as drift removal methods in frequency domain was studied. After DC trend removal, a good trend was observed between electrochemical noise (ECN) data and the results obtained from EIS and potentiodynamic polarization. Furthermore, the shot noise theory in frequency domain was applied to approach the charge of each electrochemical event (q) from the potential and current noise signals.

  13. Noise measurements on proximity effect bridges

    International Nuclear Information System (INIS)

    Decker, S.K.; Mercereau, J.E.

    1975-01-01

    Audio frequency noise density measurements were performed on weakly superconducting proximity effect bridges on using a cooled transformer and room temperature low noise preamplifier. The noise temperature of the measuring system is approximately 4 0 K for a 0.9 Ω resistor. Noise density was measured as a function of bias current and temperature for the bridges. Excess noise above that expected from Johnson noise for a resistor equal to the dynamic resistance of the bridges was observed in the region near the critical current of the device. At high currents compared to the critical current, the noise density closely approaches that given by Johnson noise

  14. Service water electrochemical monitoring development at Ontario Hydro

    International Nuclear Information System (INIS)

    Brennenstuhl, A.M.

    1994-01-01

    Ontario Hydro (OH) is currently investigating the feasibility of using electrochemical techniques for the corrosion monitoring of service water systems. To date all evaluations have been carried out in a field simulator. The studies include examining the effects of; system startup after periods of stagnation, sodium hypochlorite injection, and zebra mussel settlement on metallic surfaces. Carbon steel and Type 304L stainless steel have been evaluated. Electrochemical potential noise (EPN), electrochemical current noise (ECN) potential and coupling current were semi-continuously monitored over a period of up to one year. Data obtained from the electrochemical noise monitoring has given OH valuable insights into the mechanisms of degradation in service water systems. The high sensitivity of the electrochemical noise technique, particularly to localized corrosion has proved to be the major attraction of the system

  15. Corrosion initiation of stainless steel in HCl solution studied using electrochemical noise and in-situ atomic force microscope

    International Nuclear Information System (INIS)

    Li Yan; Hu Ronggang; Wang Jingrun; Huang Yongxia; Lin Changjian

    2009-01-01

    An in-situ atomic force microscope (AFM), optical microscope and electrochemical noise (ECN) techniques were applied to the investigation of corrosion initiations in an early stage of 1Cr18Ni9Ti stainless steel immersed in 0.5 M HCl solution. The electrochemical current noise data has been analyzed using discrete wavelet transform (DWT). For the first time, the origin of wavelet coefficients is discussed based on the correlation between the evolution of the energy distribution plot (EDP) of wavelet coefficients and topographic changes. It is found that the occurrence of initiation of metastable pitting at susceptive sites is resulted from the reductive breakdown of passive film of stainless steel in the diluted HCL solution. The coefficients d 4 -d 6 are originated from metastable pitting, d 7 represents the formation and growth of stable pitting while d 8 corresponds to the general corrosion.

  16. Electrochemical noise of the erosion-corrosion of copper in relation with its hydrodynamic parameters; Ruido electroquimico de la erosion-corrosion en cobre: su relacion con los parametros hidrodinamicos

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, I.; Romero, M.; Malo, J.M.; Uruchurtu, J.

    2010-07-01

    This work presents the electrochemical noise results obtained of the surface degradation on copper, due to erosion corrosion phenomena, which were a function of the hydrodynamic parameters of the system (fluid movement). A modified rotating cylinder (RC) comprising three ring electrodes under two rotating speeds (880 and 1750 rpm with a Reynolds numbers 1486 Re and 2972 Re, respectively) were used. Characteristic electrochemical noise spectra as a function of the hydrodynamic parameters were found, as well as surface attack intensities the noise signal. An increase and a more uniform attack due to particle impact was related to larger particle size and lesser erosion corrosion intensity, in the form of more localized attack over the surface, was obtained for smaller ones. Erosion corrosion attack presents characteristic electrochemical current and potential noise signals, according to the laminar or transitional turbulent regime and particle size added. (Author).

  17. Noise and Vibrations Measurements. External noise and vibrations measurements for offshore SODAR application

    International Nuclear Information System (INIS)

    Ormel, F.T.; Eecen, P.J.; Herman, S.A.

    2003-10-01

    The partners in the WISE project investigate whether application of the SODAR (sonic detection and ranging) measurement technique in wind energy experimental work is feasible as a replacement for cup anemometers, wind direction sensors and tall meteorological masts. In Work Package 2 of the WISE project extensive controlled experiments with the SODAR are performed. For example SODAR measurements are compared with measurements from nearby masts and different brands of SODARs are compared. Part of the work package is the measurement of vibration and noise on an offshore SODAR system. The results of these measurements are presented in this report. ECN performed measurements at an offshore location to investigate the influence of noise and vibrations on the performance of a MiniSODAR measurement system. The aim of the measurements is to quantify the effect of these external noise and vibrations disturbances on the MiniSODAR's performance. Measurements on an identical SODAR system onshore are carried out to compare the disturbances of offshore and onshore external conditions. The effect of background noise on SODAR operation has clearly been established in literature. Therefore, measurements have been performed only to establish the absolute sound pressure levels. This is done at the Measuring Platform Noordwijk (MPN) located in the North Sea, nine kilometres out of the coast at Noordwijk, The Netherlands, and at two locations onshore. At the MPN-platform, the SODAR has been moved from the middle deck to the upper deck to diminish the influence of the diesel generator needed for the electric powering of the island. Although the absolute sound pressure level became higher at the new location, this level became lower at the most important frequencies inside the SODAR, due to the use of absorbing foam. With regards to the sound pressure level the move improved the situation. The sound pressure levels measured offshore were 6 to 15 dB higher than for the two locations

  18. Pavement noise measurements in Poland

    Science.gov (United States)

    Zofka, Ewa; Zofka, Adam; Mechowski, Tomasz

    2017-09-01

    The objective of this study is to investigate the feasibility of the On-Board Sound Intensity (OBSI) system to measure tire-pavement noise in Poland. In general, sources of noise emitted by the modern vehicles are the propulsion noise, aerodynamic resistance and noise generated at the tire-pavement interface. In order to capture tire-pavement noise, the OBSI system uses a noise intensity probe installed in the close proximity of that interface. In this study, OBSI measurements were performed at different types of pavement surfaces such as stone mastic asphalt (SMA), regular asphalt concrete (HMA) as well as Portland cement concrete (PCC). The influence of several necessary OBSI measurement conditions were recognized as: testing speed, air temperature, tire pressure and tire type. The results of this study demonstrate that the OBSI system is a viable and robust tool that can be used for the quality evaluation of newly built asphalt pavements in Poland. It can be also applied to generate reliable input parameters for the noise propagation models that are used to assess the environmental impact of new and existing highway corridors.

  19. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  20. Thin film microelectrodes for electrochemical detection of neurotransmitters

    DEFF Research Database (Denmark)

    Larsen, Simon Tylsgaard

    An important signaling process in the nervous system is the release of chemical messengers called neurotransmitters from neurons. In this thesis alternative thin film electrode materials for applications targeting electrochemical detection of neurotransmitters in chip devices were evaluated...... and conductive polymer microelectrodes made of Pedot:Pss were also fabricated and used successfully to measure transmitter release from cells. The use of different thin film electrodes for low-noise amperometric measurements of single events of transmitter release from neuronal cells was studied....... For this application a very low current noise is needed together with a large temporal resolution. It was shown, that resistive and capacitive properties of thin film electrode materials are determining their usefulness in low-noise amperometric measurements. An analytical expression for the noise was derived...

  1. High temperature measurement by noise thermometry

    International Nuclear Information System (INIS)

    Decreton, M.C.

    1982-06-01

    Noise thermometry has received a lot of attention for measurements of temperatures in the high range around 1000-2000 deg. K. For these measurements, laboratory type experiments have been mostly performed. These have shown the interest of the technique when long term stability, high precision and insensibility to external conditions are concerned. This is particularly true for measurements in nuclear reactors where important drifts due to irradiation effects are experienced with other measurement techniques, as thermocouple for instance. Industrial noise thermometer experiments have not been performed extensively up to now. The subject of the present study is the development of a 1800 deg. K noise thermometer for nuclear applications. The measurement method is based on a generalized noise power approach. The rms noise voltage (Vsub(s)) and noise current (Isub(s)) are successively measured on the resistive sensor. The same quantities are also measured on a dummy short circuited probe (Vsub(d) and Isub(d)). The temperature is then deduced from these measured values by the following formula: cTsub(s) = (Vsub(s) 2 - Vsub(d) 2 )(Vsub(s)/Isub(s) - Vsub(d)/Isub(d)) - 1 , where c is a constant and Tsub(s) the absolute temperature of the sensor. This approach has the particular advantage of greatly reducing the sensibility to environmental perturbations on the leads and to the influence of amplifier noise sources. It also eliminates the necessity of resistance measurement and keeps the electronic circuits as simple as possible

  2. 14 CFR 36.801 - Noise measurement.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Noise measurement. 36.801 Section 36.801 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT NOISE STANDARDS: AIRCRAFT TYPE AND AIRWORTHINESS CERTIFICATION Helicopters § 36.801 Noise measurement. For primary, normal...

  3. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    International Nuclear Information System (INIS)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta

    2015-01-01

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping

  4. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta, E-mail: paulo.zannin@pesquisador.cnpq.br

    2015-02-15

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

  5. The influence of the cathodic process on the interpretation of electrochemical noise signals arising from pitting corrosion of stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, Helmuth Sarmiento [Federal Institute for Materials Research and Testing, Unter den Eichen 87, 12205 Berlin (Germany)], E-mail: Helmuth.sarmiento-klapper@bam.de; Goellner, Joachim [Otto von Guericke University Magdeburg, P.O. Box 4120, Magdeburg (Germany); Heyn, Andreas [Federal Institute for Materials Research and Testing, Unter den Eichen 87, 12205 Berlin (Germany); Otto von Guericke University Magdeburg, P.O. Box 4120, Magdeburg (Germany)

    2010-04-15

    The use of electrochemical noise (EN) measurements for the investigation and monitoring of corrosion has allowed many interesting advances in the corrosion science in recent years. A special advantage of EN measurements includes the possibility to detect and study the early stages of localized corrosion. Nevertheless, the understanding of the electrochemical information included in the EN signal is actually very limited. The role of the cathodic process on the EN signals remains uncertain and has not been sufficiently investigated to date. Thus, an accurate understanding of the influence of the cathodic process on the EN signal is still lacking. On the basis of different kinetics of the oxygen reduction it was established that the anodic amplitude of transients arising from pitting corrosion on stainless steel can be decreased by the corresponding electron consumption of the cathodic process. Therefore, the stronger the electron consumption, the weaker the anodic amplitude of the EN signal becomes. EN signals arising from pitting corrosion on stainless steel can be measured because the cathodic process is inhibited by the passive layer. This was confirmed by means of EN measurements under cathodic polarisation. Since the cathodic process plays a decisive role on the form of transients arising from pitting corrosion, its influence must be considered in the evaluation and interpretation of the EN signals.

  6. Ocean Ambient Noise Measurement and Theory

    CERN Document Server

    Carey, William M

    2011-01-01

    This book develops the theory of ocean ambient noise mechanisms and measurements, and also describes general noise characteristics and computational methods.  It concisely summarizes the vast ambient noise literature using theory combined with key representative results.  The air-sea boundary interaction zone is described in terms of non-dimensional variables requisite for future experiments.  Noise field coherency, rare directional measurements, and unique basin scale computations and methods are presented.  The use of satellite measurements in these basin scale models is demonstrated.  Finally, this book provides a series of appendices giving in-depth mathematical treatments.  With its complete and careful discussions of both theory and experimental results, this book will be of the greatest interest to graduate students and active researchers working in fields related to ambient noise in the ocean.

  7. Measurements techniques for transportation noise

    International Nuclear Information System (INIS)

    Brambilla, G.

    2001-01-01

    The noise from transport systems (roads, railways and aircraft) are increasing more and more both in space and in time and, therefore, they are still the major factor responsible for environmental noise pollution. The population exposed to transport noise is also increasing, and the corresponding health effects on people (i.e. annoyance and sleep disturbance) become more severe. Due to this current situation international and national legislation has been issued and implemented to reduce the harmful effects of such noise. This paper describes the techniques prescribed by recent Italian legislation to measure road, railway and aircraft noise. (author)

  8. Spin noise measurement with diamagnetic atoms

    International Nuclear Information System (INIS)

    Takeuchi, M.; Ichihara, S.; Takano, T.; Kumakura, M.; Takahashi, Y.

    2007-01-01

    We report the measurement of the atomic spin noise of the diamagnetic atom ytterbium (Yb). Yb has various merits for utilizing the quantum nature of the atomic spin ensemble compared with the paramagnetic atoms used in all previous experiments. From the magnitude of the noise level and dependence on the detuning, we concluded that we succeeded in the measurement of 171 Yb atomic spin noise in an atomic beam

  9. Integrating Electrochemical Detection with Centrifugal Microfluidics for Real-Time and Fully Automated Sample Testing

    DEFF Research Database (Denmark)

    Andreasen, Sune Zoëga; Kwasny, Dorota; Amato, Letizia

    2015-01-01

    Here we present a robust, stable and low-noise experimental set-up for performing electrochemical detection on a centrifugal microfluidic platform. By using a low-noise electronic component (electrical slip-ring) it is possible to achieve continuous, on-line monitoring of electrochemical experime......Here we present a robust, stable and low-noise experimental set-up for performing electrochemical detection on a centrifugal microfluidic platform. By using a low-noise electronic component (electrical slip-ring) it is possible to achieve continuous, on-line monitoring of electrochemical...

  10. Theory and Measurement of Signal-to-Noise Ratio in Continuous-Wave Noise Radar.

    Science.gov (United States)

    Stec, Bronisław; Susek, Waldemar

    2018-05-06

    Determination of the signal power-to-noise power ratio on the input and output of reception systems is essential to the estimation of their quality and signal reception capability. This issue is especially important in the case when both signal and noise have the same characteristic as Gaussian white noise. This article considers the problem of how a signal-to-noise ratio is changed as a result of signal processing in the correlation receiver of a noise radar in order to determine the ability to detect weak features in the presence of strong clutter-type interference. These studies concern both theoretical analysis and practical measurements of a noise radar with a digital correlation receiver for 9.2 GHz bandwidth. Firstly, signals participating individually in the correlation process are defined and the terms signal and interference are ascribed to them. Further studies show that it is possible to distinguish a signal and a noise on the input and output of a correlation receiver, respectively, when all the considered noises are in the form of white noise. Considering the above, a measurement system is designed in which it is possible to represent the actual conditions of noise radar operation and power measurement of a useful noise signal and interference noise signals—in particular the power of an internal leakage signal between a transmitter and a receiver of the noise radar. The proposed measurement stands and the obtained results show that it is possible to optimize with the use of the equipment and not with the complex processing of a noise signal. The radar parameters depend on its prospective application, such as short- and medium-range radar, ground-penetrating radar, and through-the-wall detection radar.

  11. Noise thermometry - a new temperature measuring method

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Rittinghaus, K.F.

    1975-01-01

    The thermal Johnson-Niquist noise is the basis of noise thermometry. This temperature measuring method is, e.g., of interest insofar as the noise thermometer gives absolute values as a primary thermometer and is in principle extensively independent of environmental influences and material properties. The resistance values of the measuring probe are about 10 Ohm to a few kOhm. The demands of electronics are high, the self-noise of the measuring apparatus must be as small as possible; a comparative measuring method is advantageous. 1 to 2,500 K are given as a possible temperature range. An accuracy of 0.1% could be achieved in laboratory measurements. Temperature measurements to be used in operation in a few nuclear reactors are mentioned. (HP/LH) [de

  12. Measurement and control of occupational noise

    International Nuclear Information System (INIS)

    Elammari, Muftah Faraj

    2007-01-01

    High level of environmental and occupational noise remain a problem all over the world. As problems and complaints increased dramatically by the end of the 19th and beginning of the 20th centuries focusing on the problem was intensified. In this thesis occupational noise levels at different places were measured and compared with the international permissible levels using the integrating sound level meter (Quest 2800). The calibration of the instrument was carried out before and after each measurement using the acoustic calibrator (Quest CA-12B calibrator). The method which was followed was measuring the sound pressure level of the different noise sources over a broad frequency band covering the audible frequency range using the (octave band filter, model OB-100), disregrading variation with time. Since the human ear is most sensitive in the 2-5 khz range of frequencies and least sensitive at extremely high and low frequencies the instrument was adjusted on the A weighting net work which varies with frequencies in a very similar way as that of the human ear. From the obtained results, some noise levels which were recorded were within the permissible levels i.e. below 90 dba and some noise levels were higher than the permissible limit as in janzour textile factory (95 dba), The welding workshop (120 dba), Benghazi Macaroni factory (100 dba), and near the air blowers at Zletin cement factory, Benghazi cement factory (97-10-dba) in these cases suggestions were made to minimize the problem. Concerning the noise control, four methods of noise control were tested, these methods were: reducing noise by sound absorbing material at Sirt local broadcasting radio, reducing noise by keeping a distance from the noise source, at the Boilers hall at REWDC, reducing noise by enclosures, at the compressors room at Zletin cement factory, and finally reducing noise by performing regular maintenance at Garabolli photo development centre. The percentage of noise reduction was 21%, 12

  13. Measurement time and statistics for a noise thermometer with a synthetic-noise reference

    Science.gov (United States)

    White, D. R.; Benz, S. P.; Labenski, J. R.; Nam, S. W.; Qu, J. F.; Rogalla, H.; Tew, W. L.

    2008-08-01

    This paper describes methods for reducing the statistical uncertainty in measurements made by noise thermometers using digital cross-correlators and, in particular, for thermometers using pseudo-random noise for the reference signal. First, a discrete-frequency expression for the correlation bandwidth for conventional noise thermometers is derived. It is shown how an alternative frequency-domain computation can be used to eliminate the spectral response of the correlator and increase the correlation bandwidth. The corresponding expressions for the uncertainty in the measurement of pseudo-random noise in the presence of uncorrelated thermal noise are then derived. The measurement uncertainty in this case is less than that for true thermal-noise measurements. For pseudo-random sources generating a frequency comb, an additional small reduction in uncertainty is possible, but at the cost of increasing the thermometer's sensitivity to non-linearity errors. A procedure is described for allocating integration times to further reduce the total uncertainty in temperature measurements. Finally, an important systematic error arising from the calculation of ratios of statistical variables is described.

  14. Technical report for fabrication and performance test of electrochemical/spectroscopic measurement system

    International Nuclear Information System (INIS)

    Park, Yong Joon; Cho, Young Hwan; Bae, Sang Eun; Im, Hee Jung; Song, Kyu Seok

    2010-01-01

    Development of evaluation technology of electrochemical reactions is very essential to understand chemical behavior of actinides and lanthanides in molten salt media in relation to the development of Pyrochemical process. The on-line electrochemical/spectroscopic measurement system is to produce electrochemical parameters and thermodynamic parameters of actinides and lanthanides in molten salts by using spectroscopic techniques such as UV-VIS absorption as well as electrochemical in-situ measurement techniques. The on-line electrochemical/spectroscopic measurement system can be applied to understand the chemical reactions and oxidation states of actinides and lanthanides in molten salts eventually for the Pyrochemical process

  15. Understanding the amplitudes of noise correlation measurements

    Science.gov (United States)

    Tsai, Victor C.

    2011-01-01

    Cross correlation of ambient seismic noise is known to result in time series from which station-station travel-time measurements can be made. Part of the reason that these cross-correlation travel-time measurements are reliable is that there exists a theoretical framework that quantifies how these travel times depend on the features of the ambient noise. However, corresponding theoretical results do not currently exist to describe how the amplitudes of the cross correlation depend on such features. For example, currently it is not possible to take a given distribution of noise sources and calculate the cross correlation amplitudes one would expect from such a distribution. Here, we provide a ray-theoretical framework for calculating cross correlations. This framework differs from previous work in that it explicitly accounts for attenuation as well as the spatial distribution of sources and therefore can address the issue of quantifying amplitudes in noise correlation measurements. After introducing the general framework, we apply it to two specific problems. First, we show that we can quantify the amplitudes of coherency measurements, and find that the decay of coherency with station-station spacing depends crucially on the distribution of noise sources. We suggest that researchers interested in performing attenuation measurements from noise coherency should first determine how the dominant sources of noise are distributed. Second, we show that we can quantify the signal-to-noise ratio of noise correlations more precisely than previous work, and that these signal-to-noise ratios can be estimated for given situations prior to the deployment of seismometers. It is expected that there are applications of the theoretical framework beyond the two specific cases considered, but these applications await future work.

  16. Squeezed noise in precision force measurements

    International Nuclear Information System (INIS)

    Bocko, M.F.; Bordoni, F.; Fuligni, F.; Johnson, W.W.

    1986-01-01

    The effort to build gravitational radiation antennae with sensitivity sufficient to detect bursts of radiation from supernovae in the Virgo cluster of galaxies has caused a consideration of the fundamental limits for the detection of weak forces. The existing Weber bar detectors will be eventually limited, by the phase insensitive transducers now used, to noise temperatures no better than that of the first amplifier which follows the transducer. Even for a quantum limited amplifier this may not give the sensitivity required to definitively detect gravitational radiation. In a 'back action evasion' measurement a specific phase sensitive transducer would be used. It is believed that by the technique of measuring one of the two antenna phases it is possible to reach an effective noise temperature for the measured phase which is far below the amplifier noise temperature. This is at the expense of an infinite noise temperature in the unmeasured antenna phase and is thus described as squeezing the noise. The authors outline the theoretical model for the behavior of such systems and present data from several experiments which demonstrate the main features of a back action evasion measurement. (Auth.)

  17. Electrochemical noise transient analysis for 316 and Duplex 2205 stainless steels in NaCl and FeCl; Analisis de los transitorios de ruido electroquimico para aceros inoxidables 316 Y - DUPLEX 2205 en NaCl Y FeCl

    Energy Technology Data Exchange (ETDEWEB)

    Almeraya-Calderaon, F.; Estupinan, F.; Zambrano, P.; Martinez-Villafane, A.; Borunda, A.; Colas, R.; Gaona-Tiburcio, C.

    2012-11-01

    This work shows the results obtained from electrochemical noise measurements for different materials exhibiting pitting corrosion. The transients presented in the potential and current time, correlates with the scanning electron microscopy (SEM) surface analysis. Electrochemical measurements were made at different exposure times to obtain the correlation. The materials used were stainless steel austenitic 316 and duplex 2205, immersed in ferric chloride (FeCl3) and sodium chloride (NaCl) electrolytes. SEM analysis shows that the transients observed in the time series, really correspond to the activity of pit nucleation developed over the surface of the electrodes. (Author) 31 refs.

  18. Electrochemical measurements in PWR steam generators to follow crevice chemistry

    International Nuclear Information System (INIS)

    Feron, D.

    1991-01-01

    In PWR steam generator crevices, the evolution of chemistry is important for the understanding of corrosion phenomena. Electrochemical measurements have been performed in high temperature simulated crevice environments in order to follow hideout processes and remedial actions (on-line addition of boric acid). Reported tests have been conducted with model boilers of AJAX facilities. Eccentric and concentric tube support plate crevices have been instrumented with platinum electrodes. Electrochemical measurements have been collected when model boiler was under nominal conditions (primary temperature: 335 deg C, secondary temperature: 280 deg C). They include Electrochemical Impedance Spectroscopy (EIS) and potential measurements: with EIS, sodium and boric acid hideouts have been detected and followed. Potential measurements have been performed in an attempt to measure crevice PH evolution

  19. Interpretation of incore noise measurements in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van

    1982-01-01

    A survey is given of the main incentives for power reactor noise research and the differences and similarities of noise in power and zero power systems are touched on. The basic characteristics of the adjoint method in reactor noise theory are treated. The detector adjoint functions describe the transfer functions between spatially distributed noise sources and a (neutron or gamma) detector. In particular, the spatial dependence of these functions explains the 'local' and 'global' effects in BWR noise measurements. By including thermal hydraulic feedback effects in the adjoint analysis, it is shown that the common idea of a dominant global effect at low frequencies which should result in point kinetic behaviour, is erroneous. The same analysis provides a method for nonperturbing on-line measurement of the reactor transfer function, which is demonstrated by results from measurements on a BWR in the Netherlands. In the final part of the paper some ideas are given for further research in the field of BWR noise. (author)

  20. Measuring of noise emitted by moving vehicles

    Directory of Open Access Journals (Sweden)

    Skrúcaný Tomáš

    2017-01-01

    Full Text Available The article aims to measure the intensity of the exterior noise of a vehicle in motion. It provides the results of the measurements of the external noise of selected vehicles in motion and the impact of selected factors on the sound level of driving. There are done two measurements in the paper. Results from the first one are comparing noise level of 9 passenger cars according to the Directive 71/157/EEC. The second one shows the road surface influence on the exterior noise of moving vehicle where the sound level was measured by a road whose surface was made of slightly degraded concrete, and at a different place of the same road, where the surface was renovated by applying asphalt mix onto it.

  1. Analysis of a Shock-Associated Noise Prediction Model Using Measured Jet Far-Field Noise Data

    Science.gov (United States)

    Dahl, Milo D.; Sharpe, Jacob A.

    2014-01-01

    A code for predicting supersonic jet broadband shock-associated noise was assessed using a database containing noise measurements of a jet issuing from a convergent nozzle. The jet was operated at 24 conditions covering six fully expanded Mach numbers with four total temperature ratios. To enable comparisons of the predicted shock-associated noise component spectra with data, the measured total jet noise spectra were separated into mixing noise and shock-associated noise component spectra. Comparisons between predicted and measured shock-associated noise component spectra were used to identify deficiencies in the prediction model. Proposed revisions to the model, based on a study of the overall sound pressure levels for the shock-associated noise component of the measured data, a sensitivity analysis of the model parameters with emphasis on the definition of the convection velocity parameter, and a least-squares fit of the predicted to the measured shock-associated noise component spectra, resulted in a new definition for the source strength spectrum in the model. An error analysis showed that the average error in the predicted spectra was reduced by as much as 3.5 dB for the revised model relative to the average error for the original model.

  2. Measuring Tyre Rolling Noise at the Contact Patch

    Science.gov (United States)

    Kozak, P.; Matuszkova, R.; Radimsky, M.; Kudrna, J.

    2017-06-01

    This paper deals with noise generated by road traffic. A focus is concentrated solely on one of its sources related to tyre/road interaction referred as rolling noise. The paper states brief overview of various approaches and methods used to measure this particular source of road traffic noise. On the basis of literature reviews, a unique device has been designed. Development of the measuring device and possibilities of its usage are described in detail in this paper. Obtained results of noise measurements can then be used to design measures that increase safety and a lead to better comfort on the road.

  3. Measurement of low-frequency noise in rooms

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2006-01-01

    Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close...... rooms. The sound pressure level was measured 1) in three-dimensional corners and 2) according to current Swedish and Danish measurement methods. Furthermore, the entire sound pressure distributions were measured by scanning. The Swedish and Danish measurement methods include a corner measurement...... to the highest level present in a room, rather than a room average level. In order to ensure representative noise measurements, different positions were investigated based on theoretical considerations and observations from numerical room simulations. In addition measurements were performed in three different...

  4. Interpretation of incore noise measurements in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van

    1983-01-01

    A survey is given of the main incentives for power reactor noise research, and the differences and similarities of noise in power and zero power systems are shown. After a short outline of historical developments the basic characteristics of the adjoint method in reactor noise theory are dealt with. The detector adjoint functions describe the transfer functions between spatially distributed noise sources and a (neutron or gamma) detector. In particular, the spatial dependence of these functions explains the 'local' and 'global' effects in BWR noise measurements. By including thermal hydraulic feedback effects in the adjoint analysis, it is shown that the common idea of a dominant global effect at low frequencies, which should result in point kinetic behaviour, is erroneous. The same analysis provides a method for nonperturbing on-line measurements on a BWR in The Netherlands. In the final part of the paper some ideas are given for further research in the field of BWR noise. (author)

  5. Corrosion behaviour of zinc and aluminum magnesium alloys by scanning reference electrode technique (SRET) and electrochemical noise (EN)

    International Nuclear Information System (INIS)

    Klassen, R.D.; Roberge, P.R.; Lafront, A.-M.; Oteyaka, M.O.; Ghali, E.

    2005-01-01

    The corrosion characteristics of five permanent mould magnesium alloys were studied. Two contained aluminum (AZ91D and AZ91E) and three contained zinc as the primary alloying element (ZA104 (Zn 10%, Al 4%), ZAC and ZACS). ZAC contained a small amount of calcium and ZACS contained small amounts of calcium and strontium. Two techniques were used in this study, namely 1) scanning reference electrode technique (SRET) and 2) electrochemical noise (EN). The test solution for each case was 5% NaCl saturated with Mg(OH)2 at room temperature. According to the EN measurements, the corrosion rate of AZ91D was the lowest followed by AZ91E, ZACS, ZAC and ZA104. The EN measurements showed that both the frequency and magnitude of current transients were much higher for the zinc based alloys than for the aluminum based alloys. The SRET measurements illustrated that localized corrosion occurred more frequently on the ZA104 sample than on the AZ91D sample. It seemed that increasing the level of zinc and lowering the level of aluminum relative to the levels in AZ91D does not improve corrosion resistance. (author)

  6. Investigation and measures to noise on spectroscopic measurement system in JT-60U

    International Nuclear Information System (INIS)

    Nagaya, Susumu; Kubo, Hirotaka; Sugie, Tatsuo; Onizawa, Masami; Kawai, Isao; Nakata, Hisao.

    1997-11-01

    Breakdown of a negative-ion-based neutral beam injection (N-NBI) has caused noise trouble to several systems. The control circuit of a spectroscopic measurement system had not well worked because of the noise. The noise has been measured by an optical-fiber isolation system during operation of JT-60U. The amplitude and the frequency were 15-18 V and 15 MHz respectively. The transmission noise has been reduced by putting ferrite cores to all cables connecting with the control circuits. As a result, the trouble with the spectroscopic measurement system has completely been solved. Adding condensers and resistors to the circuit was not effective to reduce the noise. (author)

  7. Electrochemical study of stress corrosion cracking of copper alloys

    International Nuclear Information System (INIS)

    Malki, Brahim

    1999-01-01

    This work deals with the electrochemical study of stress corrosion of copper alloys in aqueous environment. Selective dissolution and electrochemical oxidation are two key-points of the stress corrosion of these alloys. The first part of this thesis treats of these aspects applied to Cu-Au alloys. Measurements have been performed using classical electrochemical techniques (in potentio-dynamic, potentio-static and galvano-static modes). The conditions of occurrence of an electrochemical noise is analysed using signal processing techniques. The impact on the behavior of Cu 3 Au are discussed. In the second part, the stress corrosion problem is addressed in the case of surface oxide film formation, in particular for Cu-Zn alloys. We have found useful to extend this study to mechanical stress oxidation mechanisms in the presence of an oscillating potential electrochemical system. The aim is to examine the influence of these new electrochemical conditions (galvano-static mode) on the behavior of stressed brass. Finally, the potential distribution at crack tip is calculated in order to compare the different observations [fr

  8. Measurement noise of a point autofocus surface topography instrument

    DEFF Research Database (Denmark)

    Feng, Xiaobing; Quagliotti, Danilo; Maculotti, Giacomo

    Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment.......Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment....

  9. Electrochemical evaluation of antibacterial drugs as environment-friendly inhibitors for corrosion of carbon steel in HCl solution

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Gh.; Shahidi, M., E-mail: shahidi1965@gmail.com; Ghazanfari, D.

    2014-07-01

    The effect of penicillin G, ampicillin and amoxicillin drugs on the corrosion behavior of carbon steel (ASTM 1015) in 1.0 mol L⁻¹ hydrochloric acid solution was investigated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) techniques. The inhibition efficiency was found to increase with increasing inhibitor concentration. The effect of temperature on the rate of corrosion in the absence and presence of these drugs was also studied. Some thermodynamic parameters were computed from the effect of temperature on corrosion and inhibition processes. Adsorption of these inhibitors was found to obey Langmuir adsorption isotherm. There was a case of mixed mode of adsorption here but while penicillin was adsorbed mainly through chemisorption, two other drugs were adsorbed mainly through physisorption. Potentiodynamic polarization measurements indicated that the inhibitors were of mixed type. In addition, this paper suggests that the electrochemical noise (EN) technique under open circuit conditions as the truly noninvasive electrochemical method can be employed for the quantitative evaluation of corrosion inhibition. This was done by using the standard deviation of partial signal (SDPS) for calculation of the amount of noise charges at the particular interval of frequency, thereby obtaining the inhibition efficiency (IE) of an inhibitor. These IE values showed a reasonable agreement with those obtained from potentiodynamic polarization and EIS measurements.

  10. Electrochemical evaluation of antibacterial drugs as environment-friendly inhibitors for corrosion of carbon steel in HCl solution

    International Nuclear Information System (INIS)

    Golestani, Gh.; Shahidi, M.; Ghazanfari, D.

    2014-01-01

    The effect of penicillin G, ampicillin and amoxicillin drugs on the corrosion behavior of carbon steel (ASTM 1015) in 1.0 mol L −1 hydrochloric acid solution was investigated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) techniques. The inhibition efficiency was found to increase with increasing inhibitor concentration. The effect of temperature on the rate of corrosion in the absence and presence of these drugs was also studied. Some thermodynamic parameters were computed from the effect of temperature on corrosion and inhibition processes. Adsorption of these inhibitors was found to obey Langmuir adsorption isotherm. There was a case of mixed mode of adsorption here but while penicillin was adsorbed mainly through chemisorption, two other drugs were adsorbed mainly through physisorption. Potentiodynamic polarization measurements indicated that the inhibitors were of mixed type. In addition, this paper suggests that the electrochemical noise (EN) technique under open circuit conditions as the truly noninvasive electrochemical method can be employed for the quantitative evaluation of corrosion inhibition. This was done by using the standard deviation of partial signal (SDPS) for calculation of the amount of noise charges at the particular interval of frequency, thereby obtaining the inhibition efficiency (IE) of an inhibitor. These IE values showed a reasonable agreement with those obtained from potentiodynamic polarization and EIS measurements.

  11. RF Shot Noise Measurements in Au Atomic-scale Junctions

    Science.gov (United States)

    Chen, Ruoyu

    Conduction electrons are responsible for many physical or chemical phenomena in condensed matter systems, and their behavior can be directly studied by electronic transport measurements. In conventional transport measurements, conductance or resistance is usually the focus. Such a measurement can be as simple as a quick two terminal DC check by a multi-meter, or a more sophisticated lock-in measurement of multiple higher harmonic signals synchronized to different frequencies. Conductance carries direct information about the quasi-particle density of states and the local electronic distributions, which are usually Fermi-Dirac distribution. Conductance is modified or dominated by scattering from defacts or interfaces, and could also reflect the spin-spin exchange interactions or inelastic couplings with phonons and photons. Naturally one can ask the question: is there anything else we can measure electronically, which carries extra information that a conductance measurement does not provide? One answer to this question is the electronic noise. While the conductance reflects the average charge conduction ability of a system, noise describes how the physical quantities fluctuate around their average values. Some of the fluctuations carry information about their physical origins. This thesis will focus on one particular type of the electronic noise shot noise, but other types of noise will also be introduced and discussed. We choose to measure the radio frequency component of shot noise, combining with a modulated lock-in detection technique, which provides a method to largely get rid of other unwanted low-frequency noise signals. Au atomic-scale junctions are the systems we studied here. Au is relatively well understood and will not generate too many complications, so it's ideal as the first platform for us to understand both shot noise itself and our RF technique. On the other hand, the atomic scale raises fundamental questions about electronic transport and local

  12. High-Tc Superconducting Bolometer Noise Measurement Using Low Noise Transformers - Theory and Optimization

    Science.gov (United States)

    Aslam, Shahid; Jones, Hollis H.

    2011-01-01

    Care must always be taken when performing noise measurements on high-Tc superconducting materials to ensure that the results are not from the measurement system itself. One situation likely to occur is with low noise transformers. One of the least understood devices, it provides voltage gain for low impedance inputs (< 100 ), e.g., YBaCuO and GdBaCuO thin films, with comparatively lower noise levels than other devices for instance field effect and bipolar junction transistors. An essential point made in this paper is that because of the complex relationships between the transformer ports, input impedance variance alters the transformer s transfer function in particular, the low frequency cutoff shift. The transfer of external and intrinsic transformer noise to the output along with optimization and precautions are treated; all the while, we will cohesively connect the transfer function shift, the load impedance, and the actual noise at the transformer output.

  13. Electrochemical impedance measurement of a carbon nanotube probe electrode

    International Nuclear Information System (INIS)

    Inaba, Akira; Takei, Yusuke; Kan, Tetsuo; Shimoyama, Isao; Matsumoto, Kiyoshi

    2012-01-01

    We measured and analyzed the electrochemical impedance of carbon nanotube (CNT) probe electrodes fabricated through the physical separation of insulated CNT bridges. The fabricated CNT electrodes were free-standing CNTs that were completely covered with an insulator, except for their tips. Typical dimensions of the nanoelectrodes were 1–10 nm in CNT diameter, 80–300 nm in insulator diameter, 0.5–4 μm in exposed CNT length and 1–10 μm in probe length. The electrochemical impedance at frequencies ranging from 40 Hz to 1 MHz was measured in physiological saline. The measured impedance of the CNT electrode was constant at 32 MΩ at frequencies below 1 kHz and was inversely proportional to frequency at frequencies above 10 kHz. By means of comparison with the parasitic capacitive impedance of the insulator membrane, we confirmed that the electrode was sufficiently insulated such that the measured constant impedance was given by the exposed CNT tip. Consequently, we can use the CNT electrode for highly localized electrochemical impedance measurements below 1 kHz. Considering an equivalent circuit and the nanoscopic dimensions of the CNT electrode, we demonstrated that the constant impedance was governed by diffusion impedance, whereas the solution resistance, charge-transfer resistance and double-layer capacitance were negligible. (paper)

  14. Improving the accuracy of smart devices to measure noise exposure.

    Science.gov (United States)

    Roberts, Benjamin; Kardous, Chucri; Neitzel, Richard

    2016-11-01

    Occupational noise exposure is one of the most frequent hazards present in the workplace; up to 22 million workers have potentially hazardous noise exposures in the U.S. As a result, noise-induced hearing loss is one of the most common occupational injuries in the U.S. Workers in manufacturing, construction, and the military are at the highest risk for hearing loss. Despite the large number of people exposed to high levels of noise at work, many occupations have not been adequately evaluated for noise exposure. The objective of this experiment was to investigate whether or not iOS smartphones and other smart devices (Apple iPhones and iPods) could be used as reliable instruments to measure noise exposures. For this experiment three different types of microphones were tested with a single model of iPod and three generations of iPhones: the internal microphones on the device, a low-end lapel microphone, and a high-end lapel microphone marketed as being compliant with the International Electrotechnical Commission's (IEC) standard for a Class 2-microphone. All possible combinations of microphones and noise measurement applications were tested in a controlled environment using several different levels of pink noise ranging from 60-100 dBA. Results were compared to simultaneous measurements made using a Type 1 sound level measurement system. Analysis of variance and Tukey's honest significant difference (HSD) test were used to determine if the results differed by microphone or noise measurement application. Levels measured with external microphones combined with certain noise measurement applications did not differ significantly from levels measured with the Type 1 sound measurement system. Results showed that it may be possible to use iOS smartphones and smart devices, with specific combinations of measurement applications and calibrated external microphones, to collect reliable, occupational noise exposure data under certain conditions and within the limitations of the

  15. Electrochemical noise evaluation of anodized aluminum. Comparative study against corrosion behaviour in the atmosphere

    Directory of Open Access Journals (Sweden)

    Betancourt, N.

    2003-12-01

    Full Text Available The present work reports the evaluation of aluminum and anodized aluminum by electrochemical noise, as a part of the PATINA/CYTED project of the working group Nº 5. A visual examination is also made. The samples were exposed at several Ibero-American atmospheres up to 2 years of exposure. Different thickness of anodized aluminum were evaluated. The electrochemical potential noise of the 5 μm unexposed sample (pattern showed a different behaviour to that showed by the other anodized specimens. This could be due to a slower sealed of the samples of higher thickness. The same behaviour was observed on the samples exposed at the rural station El Pardo. According to the visual examination, the samples of bare aluminum and those of anodized 5 μm thickness were the most affected by pitting corrosion in the highly polluted atmospheres. A good correlation between corrosion behaviour determined by visual examination and EN was obtained.

    Como parte de las investigaciones de la Red PATINA el grupo de trabajo Nº 5 dedicó su atención al comportamiento del aluminio desnudo y anodizado con diferentes espesores en diferentes atmósferas de Iberoamérica. En el presente trabajo se presenta una evaluación de patrones de aluminio 99,5 % de pureza desnudo y anodizado con espesores de 15 y 25 μm, mediante ruido electroquímico. Los resultados obtenidos se comparan con el comportamiento determinado en diferentes atmósferas durante un período de 2 años. El ruido de voltaje del patrón de 5 μm de espesor presenta un comportamiento diferente al de los restantes espesores, lo que coincide con una mayor susceptibilidad a la corrosión picadura de este primer anodizado. Se reportan también algunas diferencias en el ruido de corriente. Se concluye que mediante la utilización del ruido electroquímico es posible caracterizar el aluminio con respecto a su sensibilidad a la corrosión picadura en condiciones atmosféricas.

  16. Detection of localized and general corrosion of mild steel in simulated defense nuclear waste solutions using electrochemical noise analysis

    International Nuclear Information System (INIS)

    Edgemon, G.L.; Ohl, P.C.; Bell, G.E.C.; Wilson, D.F.

    1995-12-01

    Underground waste tanks fabricated from mild steel store more than 60 million gallons of radioactive waste from 50 years of weapons production. Leaks are suspected in a significant number of tanks. The probable modes of corrosion failures are reported to be localized corrosion (e.g. nitrate stress corrosion cracking and pitting). The use of electrochemical noise (EN) for the monitoring and detection of localized corrosion processes has received considerable attention and application over the last several years. Proof of principle laboratory tests were conducted to verify the capability of EN evaluation to detect localized corrosion and to compare the predictions of general corrosion obtained from EN with those derived from other sources. Simple, pre-fabricated flat and U-bend specimens of steel alloys A516-Grade 60 (UNS K02100) and A537-CL 1 (UNS K02400) were immersed in temperature controlled simulated waste solutions. The simulated waste solution was either 5M NaNO 3 with 0.3M NaOH at 90 C or 11M NaNO 3 with 0.15M NaOH at 95 C. The electrochemical noise activity from the specimens was monitored and recorded for periods ranging between 140 and 240 hours. At the end of each test period, the specimens were metallographically examined to correlated EN data with corrosion damage

  17. Mobile Communication Devices, Ambient Noise, and Acoustic Voice Measures.

    Science.gov (United States)

    Maryn, Youri; Ysenbaert, Femke; Zarowski, Andrzej; Vanspauwen, Robby

    2017-03-01

    The ability to move with mobile communication devices (MCDs; ie, smartphones and tablet computers) may induce differences in microphone-to-mouth positioning and use in noise-packed environments, and thus influence reliability of acoustic voice measurements. This study investigated differences in various acoustic voice measures between six recording equipments in backgrounds with low and increasing noise levels. One chain of continuous speech and sustained vowel from 50 subjects with voice disorders (all separated by silence intervals) was radiated and re-recorded in an anechoic chamber with five MCDs and one high-quality recording system. These recordings were acquired in one condition without ambient noise and in four conditions with increased ambient noise. A total of 10 acoustic voice markers were obtained in the program Praat. Differences between MCDs and noise condition were assessed with Friedman repeated-measures test and posthoc Wilcoxon signed-rank tests, both for related samples, after Bonferroni correction. (1) Except median fundamental frequency and seven nonsignificant differences, MCD samples have significantly higher acoustic markers than clinical reference samples in minimal environmental noise. (2) Except median fundamental frequency, jitter local, and jitter rap, all acoustic measures on samples recorded with the reference system experienced significant influence from room noise levels. Fundamental frequency is resistant to recording system, environmental noise, and their combination. All other measures, however, were impacted by both recording system and noise condition, and especially by their combination, often already in the reference/baseline condition without added ambient noise. Caution is therefore warranted regarding implementation of MCDs as clinical recording tools, particularly when applied for treatment outcomes assessments. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Neurally based measurement and evaluation of environmental noise

    CERN Document Server

    Soeta, Yoshiharu

    2015-01-01

    This book deals with methods of measurement and evaluation of environmental noise based on an auditory neural and brain-oriented model. The model consists of the autocorrelation function (ACF) and the interaural cross-correlation function (IACF) mechanisms for signals arriving at the two ear entrances. Even when the sound pressure level of a noise is only about 35 dBA, people may feel annoyed due to the aspects of sound quality. These aspects can be formulated by the factors extracted from the ACF and IACF. Several examples of measuring environmental noise—from outdoor noise such as that of aircraft, traffic, and trains, and indoor noise such as caused by floor impact, toilets, and air-conditioning—are demonstrated. According to the noise measurement and evaluation, applications for sound design are discussed. This book provides an excellent resource for students, researchers, and practitioners in a wide range of fields, such as the automotive, railway, and electronics industries, and soundscape, architec...

  19. Statistical analysis of electrochemical noise records at aluminium corrosion; Analisis estadistico de los registros de ruido electroquimico obtenidos en la corrosion del aluminio

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, A.; Sanjurjo, M.; Bouzada, F.; Urrejola, S.

    2005-07-01

    Given that the experimental signals obtained in an electrochemical noise measurement, ENM, are recorded over a discrete time period, the most direct way of analysing them will be in the time domain resorting to starting to statistical methods. These can be classified into two groups according to use; those which attempt to quantify the degree of the corrosion process (standard deviations, statistical power); and those which attempt to provide information on the corrosion mechanism (based on the assumption that the shape of the time records is a reflection of itself). Among the later the use of the average, the skewness and the kurtosis of the signals or the pitting index can be pointed out as being able to reflect the changes in the corrosion mechanism. Noise resistance stands out above all these parameters. In this work has undertaken the statistical treatment of ENM data obtained by subjecting aluminium to three electrolytes that provoke several types of corrosion in it: passivity, pitting corrosion and generalized corrosion. (Author) 22 refs.

  20. Noise measurements of highway pavements in Texas.

    Science.gov (United States)

    2009-10-01

    This report presents the results of noise testing performed on Texas pavements between May of 2006 and the : summer of 2008. Two field test methodologies were used: roadside noise measurement with SPL meters and onvehicle : sound intensity measuremen...

  1. Treatment of electrochemical noise data by the Hilbert-Huang transform

    International Nuclear Information System (INIS)

    Rahier, A.

    2009-01-01

    Most of the classical approaches for treating electro-chemical noise (ECN) data suffer from the non-linear and non steady-state character of the delivered signal. Very often, the link between time and the local corrosion events supposedly responsible for ECN data signatures is lost during treatment, as is obvious when using the classical Fourier Transform (FT), followed by an analysis of the response in the frequency domain. In this particular case, the information directly related to the corrosion events is distributed into the full spectra, thereby preventing the operator to derive clear and precise conclusions. In 2005, we suggested an alternative data treatment based on the Hilbert-Huang transform (HHT). The latter keeps track of the time variable and copes with non-linear and non steady-state behaviours of the system under examination. In 2006, we demonstrated the applicability of the newly proposed data treatment in the case of ECN data collected under BWR (Boiling Water Reactor) conditions. In 2007, we collected additional ECN data and started a preliminary investigation of two mathematical restrictions that are susceptible to impair the interpretation of the results. We discovered a possible modification of the Hilbert transform allowing generating controlled phase shifts that are different from pi/2 as is always the case for the Hilbert transform

  2. Comparison of measured and predicted airfoil self-noise with application to wind turbine noise reduction

    International Nuclear Information System (INIS)

    Dassen, T.; Parchen, R.; Guidati, G.; Wagner, S.; Kang, S.; Khodak, A.E.

    1998-01-01

    In the ongoing JOULE-III project 'Development of Design Tools for Reduced Aerodynamic Noise Wind Turbines (DRAW)', prediction codes for inflow-turbulence (IT) noise and turbulent boundary layer trailing-edge (TE) noise, are developed and validated. It is shown that the differences in IT noise radiation between airfoils having a different shape, are correctly predicted. The first, preliminary comparison made between predicted and measured TE noise spectra yields satisfactory results. 17 refs

  3. Noise measurements during high-frequency oscillatory and conventional mechanical ventilation.

    Science.gov (United States)

    Berens, R J; Weigle, C G

    1995-10-01

    To evaluate the noise levels with high-frequency oscillatory ventilation and conventional mechanical ventilation. An observational, prospective study. Pediatric intensive care unit. The caretakers and environment of the pediatric intensive care unit. High-frequency oscillatory and conventional mechanical ventilation. Caretakers evaluated noise using a visual analog scale. Noise was measured with a decibel meter and an octave band frequency filter. There was twice as much noise perceived by the caretakers and as measured on the decibel A scale. All measures showed significantly greater noise, especially at low frequencies, with high-frequency oscillatory ventilation. High-frequency oscillatory ventilation exposes the patient to twice as much noise as does the use of conventional mechanical ventilation.

  4. Uncorrelated Noise in Turbulence Measurements

    DEFF Research Database (Denmark)

    Kristensen, Leif; Lenschow, D. H.

    1985-01-01

    of atmospheric variability. The authors assume that the measured signal is a representation of a variable that is continuous on the scale of interest in the atmosphere. Uncorrelated noise affects the autovariance function (or, equivalently, the structure function) only between zero and the first lag, while its...... effect is smeared across the entire power spectrum. For this reason, quantities such as variance dissipation may be more conveniently estimated from the structure function than from the spectrum. The modeling results are confirmed by artificially modifying a test time series with Poisson noise...

  5. Debuncher Momentum Cooling Systems Signal to Noise Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pasquinelli, Ralph J.; /Fermilab

    2001-12-18

    The Debuncher Momentum cooling systems were carefully measured for signal to noise. It was observed that cooling performance was not optimum. Closer inspection shows that the installed front-end bandpass filters are wider than the pickup response. (The original filters were specified to be wider so that none of the available bandwidth would be clipped.) The end result is excess noise is amplified and passed onto the kickers unimpeded, hence, reducing the achievable system gain. From this data, new filters should be designed to improve performance. New system bandwidths are specified on the data figures. Also included are the transfer function measurements that clearly show adjacent band response. In band 4 upper, the adjacent lobes are strong and out of phase. This is also degrading the system performance. The correlation between spectrum analyzer signal to noise and network analyzer system transfer functions is very strong. The table below has a calculation of expected improvement of front noise reduction by means of building new front-end bandpass filters. The calculation is based on a flat input noise spectrum and is a linear estimation of improvement. The listed 3dB bandwidths of the original filters are from measured data. The expected bandwidth is taken from the linear spectrum analyzer plots and is closer to a 10 dB bandwidth making the percentage improvement conservative. The signal to noise measurements are taken with circulating pbars in the Debuncher. One cooling system was measured at a time with all others off. Beam currents are below ten microamperes.

  6. Debuncher Momentum Cooling Systems Signal to Noise Measurements

    International Nuclear Information System (INIS)

    Pasquinelli, Ralph J.

    2001-01-01

    The Debuncher Momentum cooling systems were carefully measured for signal to noise. It was observed that cooling performance was not optimum. Closer inspection shows that the installed front-end bandpass filters are wider than the pickup response. (The original filters were specified to be wider so that none of the available bandwidth would be clipped.) The end result is excess noise is amplified and passed onto the kickers unimpeded, hence, reducing the achievable system gain. From this data, new filters should be designed to improve performance. New system bandwidths are specified on the data figures. Also included are the transfer function measurements that clearly show adjacent band response. In band 4 upper, the adjacent lobes are strong and out of phase. This is also degrading the system performance. The correlation between spectrum analyzer signal to noise and network analyzer system transfer functions is very strong. The table below has a calculation of expected improvement of front noise reduction by means of building new front-end bandpass filters. The calculation is based on a flat input noise spectrum and is a linear estimation of improvement. The listed 3dB bandwidths of the original filters are from measured data. The expected bandwidth is taken from the linear spectrum analyzer plots and is closer to a 10 dB bandwidth making the percentage improvement conservative. The signal to noise measurements are taken with circulating pbars in the Debuncher. One cooling system was measured at a time with all others off. Beam currents are below ten microamperes.

  7. Data Quality Assurance for Supersonic Jet Noise Measurements

    Science.gov (United States)

    Brown, Clifford A.; Henderson, Brenda S.; Bridges, James E.

    2010-01-01

    The noise created by a supersonic aircraft is a primary concern in the design of future high-speed planes. The jet noise reduction technologies required on these aircraft will be developed using scale-models mounted to experimental jet rigs designed to simulate the exhaust gases from a full-scale jet engine. The jet noise data collected in these experiments must accurately predict the noise levels produced by the full-scale hardware in order to be a useful development tool. A methodology has been adopted at the NASA Glenn Research Center s Aero-Acoustic Propulsion Laboratory to insure the quality of the supersonic jet noise data acquired from the facility s High Flow Jet Exit Rig so that it can be used to develop future nozzle technologies that reduce supersonic jet noise. The methodology relies on mitigating extraneous noise sources, examining the impact of measurement location on the acoustic results, and investigating the facility independence of the measurements. The methodology is documented here as a basis for validating future improvements and its limitations are noted so that they do not affect the data analysis. Maintaining a high quality jet noise laboratory is an ongoing process. By carefully examining the data produced and continually following this methodology, data quality can be maintained and improved over time.

  8. Measuring low-frequency noise indoors

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2008-01-01

    that is exceeded in 10% of the volume of a room (L10) is proposed as a rational and objective target for a measurement method. In Sweden and Denmark rules exist for measuring low-frequency noise indoors. The performance of these procedures was investigated in three rooms. The results from the Swedish method were...

  9. Development of Self-Powered Wireless-Ready High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring for Boiler Tubes in Next Generation Coal-based Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xingbo [West Virginia Univ., Morgantown, WV (United States)

    2015-06-30

    The key innovation of this project is the synergy of the high temperature sensor technology based on the science of electrochemical measurement and state-of-the-art wireless communication technology. A novel self-powered wireless high temperature electrochemical sensor system has been developed for coal-fired boilers used for power generation. An initial prototype of the in-situ sensor demonstrated the capability of the wireless communication system in the laboratory and in a pilot plant (Industrial USC Boiler Setting) environment to acquire electrochemical potential and current signals during the corrosion process. Uniform and localized under-coal ash deposit corrosion behavior of Inconel 740 superalloy has been studied at different simulated coal ash hot corrosion environments using the developed sensor. Two typical potential noise patterns were found to correlate with the oxidation and sulfidation stages in the hot coal ash corrosion process. Two characteristic current noise patterns indicate the extent of the corrosion. There was a good correlation between the responses of electrochemical test data and the results from corroded surface analysis. Wireless electrochemical potential and current noise signals from a simulated coal ash hot corrosion process were concurrently transmitted and recorded. The results from the performance evaluation of the sensor confirm a high accuracy in the thermodynamic and kinetic response represented by the electrochemical noise and impedance test data.

  10. Noise in the Measurement of Light with Photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Robben, F

    1968-05-15

    In order to be able to compare measurements derived from the anode current of a photomultiplier with measurement derived from photoelectron pulse counting, a systematic investigation of the properties of some photomultiplier tubes has been made. This has led to a correlation of the properties of a photomultiplier based on the quantum efficiency {eta}, the gain G, a photoelectron loss factor S and an effective dark rate D. In terms of these quantities the signal to noise ratio of an experimental measurement can be calculated, given the light flux and measurement technique. The fluctuations in a photomultiplier output are divided into two parts; Poisson fluctuations, and those due to excess noise. It is experimentally shown, from measurements on a 931A photomultiplier, that the excess noise exceeds the Poisson fluctuations only at very low frequencies, or long DC measurement times (> 10 s), for both pulse counting and anode current measurements. The Poisson fluctuations are found to be approximately the same for both pulse counting and anode current measurements, at both high light levels where the dark current, or dark pulses, are negligible, as well as at low light levels where the dark current is dominant. The excess noise is found to be somewhat greater in the case of anode current measurements. Thus both pulse counting and anode current measurement techniques have nearly identical noise properties, as far as the photomultiplier is concerned, and selection of either experimental technique depends primarily on the properties of the electronic equipment. By use of a synchronous detection technique, the variance of the pulse count was measured experimentally to an accuracy of {+-} 4 %, and was shown to be in agreement with that predicted by Poisson statistics.

  11. Power reactor noise measurements in Hungary

    International Nuclear Information System (INIS)

    Pallagi, D.; Horanyi, S.; Hargitai, T.

    1975-01-01

    An outline is given of the history of reactor noise research in Hungary. A brief description is given of studies in the WWR-SM reactor, a modified version of the original WWR-S thermal reactor, for the detection of in-core simulated boiling by analysis of the noise of out-of-core ionization chambers. Coolant velocity measurements by transit time analysis of temperature fluctuations are described. (U.K.)

  12. Measurement of luminance noise and chromaticity noise of LCDs with a colorimeter and a color camera

    Science.gov (United States)

    Roehrig, H.; Dallas, W. J.; Krupinski, E. A.; Redford, Gary R.

    2007-09-01

    This communication focuses on physical evaluation of image quality of displays for applications in medical imaging. In particular we were interested in luminance noise as well as chromaticity noise of LCDs. Luminance noise has been encountered in the study of monochrome LCDs for some time, but chromaticity noise is a new type of noise which has been encountered first when monochrome and color LCDs were compared in an ROC study. In this present study one color and one monochrome 3 M-pixel LCDs were studied. Both were DICOM calibrated with equal dynamic range. We used a Konica Minolta Chroma Meter CS-200 as well as a Foveon color camera to estimate luminance and chrominance variations of the displays. We also used a simulation experiment to estimate luminance noise. The measurements with the colorimeter were consistent. The measurements with the Foveon color camera were very preliminary as color cameras had never been used for image quality measurements. However they were extremely promising. The measurements with the colorimeter and the simulation results showed that the luminance and chromaticity noise of the color LCD were larger than that of the monochrome LCD. Under the condition that an adequate calibration method and image QA/QC program for color displays are available, we expect color LCDs may be ready for radiology in very near future.

  13. Noise in NC-AFM measurements with significant tip–sample interaction

    Directory of Open Access Journals (Sweden)

    Jannis Lübbe

    2016-12-01

    Full Text Available The frequency shift noise in non-contact atomic force microscopy (NC-AFM imaging and spectroscopy consists of thermal noise and detection system noise with an additional contribution from amplitude noise if there are significant tip–sample interactions. The total noise power spectral density DΔf(fm is, however, not just the sum of these noise contributions. Instead its magnitude and spectral characteristics are determined by the strongly non-linear tip–sample interaction, by the coupling between the amplitude and tip–sample distance control loops of the NC-AFM system as well as by the characteristics of the phase locked loop (PLL detector used for frequency demodulation. Here, we measure DΔf(fm for various NC-AFM parameter settings representing realistic measurement conditions and compare experimental data to simulations based on a model of the NC-AFM system that includes the tip–sample interaction. The good agreement between predicted and measured noise spectra confirms that the model covers the relevant noise contributions and interactions. Results yield a general understanding of noise generation and propagation in the NC-AFM and provide a quantitative prediction of noise for given experimental parameters. We derive strategies for noise-optimised imaging and spectroscopy and outline a full optimisation procedure for the instrumentation and control loops.

  14. Noise evaluation of a point autofocus surface topography measuring instrument

    Science.gov (United States)

    Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard

    2018-06-01

    In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.

  15. Measured Noise from Small Unmanned Aerial Vehicles

    Science.gov (United States)

    Cabell, Randolph; McSwain, Robert; Grosveld, Ferdinand

    2016-01-01

    Proposed uses of small unmanned aerial vehicles (UAVs), including home package delivery, have the potential to expose large portions of communities to a new noise source. This paper discusses results of flyover noise measurements of four small UAVs, including an internal combustion-powered model airplane and three battery-powered multicopters. Basic noise characteristics of these vehicles are discussed, including spectral properties and sound level metrics such as sound pressure level, effective perceived noise level, and sound exposure level. The size and aerodynamic characteristics of the multicopters in particular make their flight path susceptible to atmospheric disturbances such as wind gusts. These gusts, coupled with a flight control system that varies rotor speed to maintain vehicle stability, create an unsteady acoustic signature. The spectral variations resulting from this unsteadiness are explored, in both hover and flyover conditions for the multicopters. The time varying noise, which differs from the relatively steady noise generated by large transport aircraft, may complicate the prediction of human annoyance using conventional sound level metrics.

  16. Estimation of noise-free variance to measure heterogeneity.

    Directory of Open Access Journals (Sweden)

    Tilo Winkler

    Full Text Available Variance is a statistical parameter used to characterize heterogeneity or variability in data sets. However, measurements commonly include noise, as random errors superimposed to the actual value, which may substantially increase the variance compared to a noise-free data set. Our aim was to develop and validate a method to estimate noise-free spatial heterogeneity of pulmonary perfusion using dynamic positron emission tomography (PET scans. On theoretical grounds, we demonstrate a linear relationship between the total variance of a data set derived from averages of n multiple measurements, and the reciprocal of n. Using multiple measurements with varying n yields estimates of the linear relationship including the noise-free variance as the constant parameter. In PET images, n is proportional to the number of registered decay events, and the variance of the image is typically normalized by the square of its mean value yielding a coefficient of variation squared (CV(2. The method was evaluated with a Jaszczak phantom as reference spatial heterogeneity (CV(r(2 for comparison with our estimate of noise-free or 'true' heterogeneity (CV(t(2. We found that CV(t(2 was only 5.4% higher than CV(r2. Additional evaluations were conducted on 38 PET scans of pulmonary perfusion using (13NN-saline injection. The mean CV(t(2 was 0.10 (range: 0.03-0.30, while the mean CV(2 including noise was 0.24 (range: 0.10-0.59. CV(t(2 was in average 41.5% of the CV(2 measured including noise (range: 17.8-71.2%. The reproducibility of CV(t(2 was evaluated using three repeated PET scans from five subjects. Individual CV(t(2 were within 16% of each subject's mean and paired t-tests revealed no difference among the results from the three consecutive PET scans. In conclusion, our method provides reliable noise-free estimates of CV(t(2 in PET scans, and may be useful for similar statistical problems in experimental data.

  17. An examination of the parametric properties of four noise sensitivity measures

    DEFF Research Database (Denmark)

    van Kamp, Irene; Ellermeier, Wolfgang; Lopez-Barrio, Isabel

    2006-01-01

    Noise sensitivity (NS) is a personality trait with a strong influence on reactions to noise. Studies of reaction should include a standard measure of NS that is founded on a theoretically justified definition of NS, and examination of existing NS measures' parametric properties (internal consiste......, demographics and lifestyle). A standard NS measure should demonstrate high reliability, and should predict responses to noise. Discussion is welcomed and will focus on validation strategies and optimizing the study design.......Noise sensitivity (NS) is a personality trait with a strong influence on reactions to noise. Studies of reaction should include a standard measure of NS that is founded on a theoretically justified definition of NS, and examination of existing NS measures' parametric properties (internal...... consistency; stability; convergent and predictive validity). At each of 6 laboratory centres (Aalborg; London; Sydney; Dortmund; Madrid, Amsterdam), participants will complete four NS measures on each of two occasions. In one occasion, participants will complete a task while exposed to recorded aircraft noise...

  18. Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction.

    Science.gov (United States)

    Ricketts, Todd A; Hornsby, Benjamin W Y

    2005-05-01

    This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

  19. Noise measurement on Preshower Si sensors

    CERN Document Server

    Evangelou, Ioannis; Barney, David; Bloch, Philippe; Elsha, Vladimir; Go, Apollo; Kloukinas, Kostas; Kokkas, Panagiotis; Manthos, Nikolaos; Peisert, Anna; Prouskas, C; Reynaud, Serge; Triantis, Frixos A; Tzoulis, Nikolaos; Zub, E

    2002-01-01

    Throughout the past couple of years when we were designing the Preshower silicon sensors we have noticed that some of them have strips with a noise higher than the average and not correlated to the leakage current. In order to investigate this effect we have developed a set-up for noise measurement on wafers and diced sensors that does not require bonding. The set-up is based on the DeltaStream chip coupled to a probe card with 32 pins at a pitch of 1.9 mm. All the digital electronics, including the analogue-to-digital converter and a microprocessor, is placed on a motherboard which communicates with a PC via an RS232 line. We have tested 45 sensors and found that some strips which have an above average noise, also have a higher relative current increase as a function of voltage, deltaI/(I deltaV), even though their leakage current is below 50 nA. We also observed that on these strips th e breakdown occurs within about 60 V from the onset of the noise. The source of this noise is not yet clear and the investi...

  20. Noise Reduction of Measurement Data using Linear Digital Filters

    Directory of Open Access Journals (Sweden)

    Hitzmann B.

    2007-12-01

    Full Text Available In this paper Butterworth, Chebyshev (Type I and II and Elliptic digital filters are designed for signal noise reduction. On-line data measurements of substrate concentration from E. coli fed-batch cultivation process are used. Application of the designed filters leads to a successful noise reduction of on-line glucose measurements. The digital filters presented here are simple, easy to implement and effective - the used filters allow for a smart compromise between signal information and noise corruption.

  1. Study crevice corrosion alloys C-22 and 625 by electrochemical noise

    International Nuclear Information System (INIS)

    Ungaro, María L.; Carranza, Ricardo M.; Rodríguez, Martín A.

    2013-01-01

    C-22 and 625 alloys are two of the Ni –Cr-Mo alloys considered as candidate materials to form the corrosion resistance engineered barriers for nuclear waste repositories. The corrosion resistance of these alloys is remarkable in a wide variety of environments. Despite of their resistance these alloys are susceptible to crevice corrosion in a certain aggressive environments. This work presents the use of electrochemical noise technique to study crevice corrosion susceptibility of alloys C-22 and 625 in 1M NaCl acidic solutions at 60ºC and 90ºC. Asymmetrical electrodes and a complementary platinum electrode were used to assess the influence of cathodic reaction in crevice process. The obtained records were analyzed directly and through statistical parameters. The potential drop and the simultaneous increment of the current records indicated the occurrence of crevice corrosion. The alternative use of a platinum electrode resulted in higher currents and higher potentials and reduced the induction time to crevice formation. The reason for this behavior is that platinum surface allows faster cathodic reactions than C-22 and 625 alloys. The standard deviation of the current records was responsive to the crevice corrosion intensity. C-22 alloy had better crevice corrosion performance than 625 alloy. (author)

  2. Measurement of the environmental noise at the Torseroed wind turbine site

    International Nuclear Information System (INIS)

    Fegeant, Olivier

    2000-12-01

    Further to complaints about the noise generated by a Micon 600 kW wind turbine, measurements of both noise immission and noise emission were performed at the Torseroed site. The measurements and analysis presented in this report were carried out by following the recommendations of the IEA documents for noise emission and immission measurements. It was found that the immission level, i.e. the wind turbine sound, at one of the nearest dwelling, namely Solglaentan, is 39 dB(A) for a wind speed of 8 m/s at hub height. Measurements carried out close to the turbine show that the sound power level of the turbine is 4.3 dB higher than the A-weighted level given by the supplier. Furthermore, the noise level increases more rapidly as a function of the wind speed than what is expected from the values furnished by the manufacturer. The measurements results also show that the background noise level is unusually low at Solglaentan

  3. Evaluation of the Microbiologically Influenced Corrosion in a carbon steel making use of electrochemical techniques

    International Nuclear Information System (INIS)

    Diaz S, A.C.; Arganis, C.; Ayala, V.; Gachuz, M.; Merino, J.; Suarez, S.; Brena, M.; Luna, P.

    2001-01-01

    The Microbiologically Influenced Corrosion (MIC) has been identified as a problem of the nuclear plants systems in the last years. The electrochemical behavior of metal coupons of carbon steel submitted to the action of sulfate reducing bacteria (SRB) was evaluated, making use of the electrochemical techniques of direct current as well as electrochemical noise. The generated results show a little variation in the corrosion velocities which obtained by Tafel extrapolation and resistance to the linear polarization, whereas the electrochemical noise technique presented important differences as regards the registered behavior in environment with and without microorganisms. (Author)

  4. Cross-correlation measurement of quantum shot noise using homemade transimpedance amplifiers

    International Nuclear Information System (INIS)

    Hashisaka, Masayuki; Ota, Tomoaki; Yamagishi, Masakazu; Fujisawa, Toshimasa; Muraki, Koji

    2014-01-01

    We report a cross-correlation measurement system, based on a new approach, which can be used to measure shot noise in a mesoscopic conductor at milliKelvin temperatures. In contrast to other measurement systems in which high-speed low-noise voltage amplifiers are commonly used, our system employs homemade transimpedance amplifiers (TAs). The low input impedance of the TAs significantly reduces the crosstalk caused by unavoidable parasitic capacitance between wires. The TAs are designed to have a flat gain over a frequency band from 2 kHz to 1 MHz. Low-noise performance is attained by installing the TAs at a 4 K stage of a dilution refrigerator. Our system thus fulfills the technical requirements for cross-correlation measurements: low noise floor, high frequency band, and negligible crosstalk between two signal lines. Using our system, shot noise generated at a quantum point contact embedded in a quantum Hall system is measured. The good agreement between the obtained shot-noise data and theoretical predictions demonstrates the accuracy of the measurements

  5. Analysis of electrochemical noise data in both time and frequency domains to evaluate the effect of ZnO nanopowder addition on the corrosion protection performance of epoxy coatings

    Directory of Open Access Journals (Sweden)

    H. Ashassi-Sorkhabi

    2016-11-01

    Full Text Available Epoxy–ZnO nanocomposite coatings have been developed for corrosion protection of steel. Structural characterization of the prepared nanocomposites was performed using scanning electron microscopy (SEM. The anti-corrosive properties of the coatings were evaluated by electrochemical noise (EN. On the basis of the EN results in both time and frequency domains, the nanocomposite material with low ZnO concentration (0.1% wt.% was found to be much superior in corrosion protection when tested in aqueous NaCl electrolyte. Finally, EIS measurements were carried out and the data fitted with suitable equivalent circuit. Resistance parameters obtained by both techniques were found to be in relatively good agreement.

  6. Effects of measurement noise on modal parameter identification

    International Nuclear Information System (INIS)

    Dorvash, S; Pakzad, S N

    2012-01-01

    In the past decade, much research has been conducted on data-driven structural health monitoring (SHM) algorithms with use of sensor measurements. A fundamental step in this SHM application is to identify the dynamic characteristics of structures. Despite the significant efforts devoted to development and enhancement of the modal parameter identification algorithms, there are still substantial uncertainties in the results obtained in real-life deployments. One of the sources of uncertainties in the results is the existence of noise in the measurement data. Depending on the subsequent application of the system identification, the level of uncertainty in the results and, consequently, the level of noise contamination can be very important. As an effort towards understanding the effect of measurement noise on the modal identification, this paper presents parameters that quantify the effects of measurement noise on the modal identification process and determine their influence on the accuracy of results. The performance of these parameters is validated by a numerically simulated example. They are then used to investigate the accuracy of identified modal properties of the Golden Gate Bridge using ambient data collected by wireless sensors. The vibration monitoring tests of the Golden Gate Bridge provided two synchronized data sets collected by two different sensor types. The influence of the sensor noise level on the accuracy of results is investigated throughout this work and it is shown that high quality sensors provide more accurate results as the physical contribution of response in their measured data is significantly higher. Additionally, higher purity and consistency of modal parameters, identified by higher quality sensors, is observed in the results. (paper)

  7. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  8. Uncertainty In Measuring Noise Parameters Of a Communication Receiver

    International Nuclear Information System (INIS)

    Korcz, Karol; Palczynska, Beata; Spiralski, Ludwik

    2005-01-01

    The paper presents the method of assessing uncertainty in measuring the usable sensitivity Es of communication receiver. The influence of partial uncertainties of measuring the noise factor F and the energy pass band of the receiver Δf on the combined standard uncertainty level is analyzed. The method to assess the uncertainty in measuring the noise factor on the basis of the systematic component of uncertainty, assuming that the main source of measurement uncertainty is the hardware of the measuring system, is proposed. The assessment of uncertainty in measuring the pass band of the receiver is determined with the assumption that input quantities of the measurement equation are not correlated. They are successive, discrete values of the spectral power density of the noise on the output of receiver. The results of the analyses of particular uncertainties components of measuring the sensitivity, which were carried out for a typical communication receiver, are presented

  9. Measurement of MOSFET LF Noise Under Large Signal RF Excitation

    NARCIS (Netherlands)

    van der Wel, A.P.; Klumperink, Eric A.M.; Nauta, Bram

    A new measurement technique is presented that allows measurement of MOSFET LF noise under large signal RF excitation. Measurements indicate that MOSFETS exhibit a reduction in LF noise when they are cycled from inversion to accummulation and that this reduction does not depend on the frequency of

  10. On the use of mobile phones and wearable microphones for noise exposure measurements: Calibration and measurement accuracy

    Science.gov (United States)

    Dumoulin, Romain

    Despite the fact that noise-induced hearing loss remains the number one occupational disease in developed countries, individual noise exposure levels are still rarely known and infrequently tracked. Indeed, efforts to standardize noise exposure levels present disadvantages such as costly instrumentation and difficulties associated with on site implementation. Given their advanced technical capabilities and widespread daily usage, mobile phones could be used to measure noise levels and make noise monitoring more accessible. However, the use of mobile phones for measuring noise exposure is currently limited due to the lack of formal procedures for their calibration and challenges regarding the measurement procedure. Our research investigated the calibration of mobile phone-based solutions for measuring noise exposure using a mobile phone's built-in microphones and wearable external microphones. The proposed calibration approach integrated corrections that took into account microphone placement error. The corrections were of two types: frequency-dependent, using a digital filter and noise level-dependent, based on the difference between the C-weighted noise level minus A-weighted noise level of the noise measured by the phone. The electro-acoustical limitations and measurement calibration procedure of the mobile phone were investigated. The study also sought to quantify the effect of noise exposure characteristics on the accuracy of calibrated mobile phone measurements. Measurements were carried out in reverberant and semi-anechoic chambers with several mobiles phone units of the same model, two types of external devices (an earpiece and a headset with an in-line microphone) and an acoustical test fixture (ATF). The proposed calibration approach significantly improved the accuracy of the noise level measurements in diffuse and free fields, with better results in the diffuse field and with ATF positions causing little or no acoustic shadowing. Several sources of errors

  11. Combination of the optical waveguide lightmode spectroscopy method with electrochemical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Szendro, I.; Erdelyi, K.; Fabian, M. [MicroVacuum Ltd., Kerekgyarto u.: 10, H-1147 Budapest (Hungary); Puskas, Zs. [Minvasive Ltd., Goldmann Gy. ter 3., H-1111 Budapest (Hungary); Adanyi, N. [Central Food Research Institute, H-1537 Budapest, P.O.B. 393 (Hungary); Somogyi, K. [MicroVacuum Ltd., Kerekgyarto u.: 10, H-1147 Budapest (Hungary)], E-mail: karoly.somogyi@microvacuum.com

    2008-09-30

    Optical waveguides are normally sensitive to the surrounding media and also to the surface contaminations. The effective refractive index changes at the surface. Various sensor systems were developed based on this effect. One of the most sensitive and effective methods is the optical waveguide lightmode spectroscopy (OWLS). At the same time, electrochemical methods are widely used both in inorganic and organic chemistry, and also advantages in microbiology were demonstrated. In this work, efforts are made and results are presented for the combination of these two methods for simultaneous measurement of refractive index and electrical current changes caused by the presence of cells/molecules/ions to be investigated. An electrically conductive indium tin oxide (ITO) nanolayer is deposited and activated on the top of the OWLS planar waveguide oxide layer. ITO layers serve as working electrodes in the electrochemical measurements. The basic setup and an integrated system are demonstrated here. Measurements using H{sub 2}O{sub 2}, toluidine blue solutions, and KCl and TRIS solutions as buffer and transport media are represented. Measurements show both the changes detected by the sensor layer and the effect of the applied potential in cyclic and chrono voltammetric measurements. Results demonstrate an effective combination of optical and electrochemical methods.

  12. Evaluating noise abatement measures using strategic noise maps

    NARCIS (Netherlands)

    Borst, H.C.; Miedema, H.M.E.; Laan, W.P.N. van der; Lohman, W.J.A.

    2006-01-01

    Noise annoyance due to transportation is widespread in industrialized countries and in urban areas in the developing countries. The European Noise Directive (END) requires an assessment of the noise situation as well as the formulation of action plans for the reduction of the number of people

  13. Prediction of Landing Gear Noise Reduction and Comparison to Measurements

    Science.gov (United States)

    Lopes, Leonard V.

    2010-01-01

    Noise continues to be an ongoing problem for existing aircraft in flight and is projected to be a concern for next generation designs. During landing, when the engines are operating at reduced power, the noise from the airframe, of which landing gear noise is an important part, is equal to the engine noise. There are several methods of predicting landing gear noise, but none have been applied to predict the change in noise due to a change in landing gear design. The current effort uses the Landing Gear Model and Acoustic Prediction (LGMAP) code, developed at The Pennsylvania State University to predict the noise from landing gear. These predictions include the influence of noise reduction concepts on the landing gear noise. LGMAP is compared to wind tunnel experiments of a 6.3%-scale Boeing 777 main gear performed in the Quiet Flow Facility (QFF) at NASA Langley. The geometries tested in the QFF include the landing gear with and without a toboggan fairing and the door. It is shown that LGMAP is able to predict the noise directives and spectra from the model-scale test for the baseline configuration as accurately as current gear prediction methods. However, LGMAP is also able to predict the difference in noise caused by the toboggan fairing and by removing the landing gear door. LGMAP is also compared to far-field ground-based flush-mounted microphone measurements from the 2005 Quiet Technology Demonstrator 2 (QTD 2) flight test. These comparisons include a Boeing 777-300ER with and without a toboggan fairing that demonstrate that LGMAP can be applied to full-scale flyover measurements. LGMAP predictions of the noise generated by the nose gear on the main gear measurements are also shown.

  14. Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.

    Science.gov (United States)

    Rivera-Serrano, Nilka; Pagan, Miraida; Colón-Rodríguez, Joanisse; Fuster, Christian; Vélez, Román; Almodovar-Faria, Jose; Jiménez-Rivera, Carlos; Cunci, Lisandro

    2018-02-06

    In this study, electrochemical impedance spectroscopy was used for the first time to study the adsorption of dopamine in carbon fiber microelectrodes. In order to show a proof-of-concept, static and dynamic measurements were taken at potentials ranging from -0.4 to 0.8 V versus Ag|AgCl to demonstrate the versatility of this technique to study dopamine without the need of its oxidation. We used electrochemical impedance spectroscopy and single frequency electrochemical impedance to measure different concentrations of dopamine as low as 1 nM. Moreover, the capacitance of the microelectrodes surface was found to decrease due to dopamine adsorption, which is dependent on its concentration. The effect of dissolved oxygen and electrochemical oxidation of the surface in the detection of dopamine was also studied. Nonoxidized and oxidized carbon fiber microelectrodes were prepared and characterized by optical microscopy, scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Optimum working parameters of the electrodes, such as frequency and voltage, were obtained for better measurement. Electrochemical impedance of dopamine was determined at different concentration, voltages, and frequencies. Finally, dynamic experiments were conducted using a flow cell and single frequency impedance in order to study continuous and real-time measurements of dopamine.

  15. Waterwall corrosion evaluation in coal-fired boilers using electrochemical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Davis, K.; Lee, C.; Seeley, R.; Harding, S.; Heap, M.; Cox, W.

    2000-07-01

    Until recently, waterwall corrosion in North American coal-fired boilers was uncommon and relatively mild. However, the introduction of combustion modifications to reduce in-furnace NOx formation has led to notable increases in the frequency and severity of waterwall wastage. Reaction Engineering International (REI) has worked with the Department of Energy and EPRI to improve predictive capabilities and provide solutions for furnace wall wastage for a wide range of coal-fired furnaces. To date, this work has emphasized computational simulations. More recently, REI in partnership with Corrosion Management has begun complementary efforts to improve their services by evaluating technologies capable of determining the location/rate of high water wall wastage resulting from corrosion. After an evaluation of commercially available options, electrochemical noise (EN) technology has been chosen for continued development. This approach has been successfully applied to corrosion-related problems involving acid dewpoint corrosion in flue gas ductwork, FGD systems, cooling water systems, oil and gas production, and acid cleaning (Cox et al, 1999). This paper presents the results of preliminary testing of an EN probe in a high temperature environment typical of the lower furnace of a cyclone-fired boiler operating under staged conditions. The relationship between electrochemical responses and (1) stoichiometry and (2) local hydrogen sulfide concentration is investigated and the qualitative and quantitative usefulness of the approach for on-line risk management is considered.

  16. Vibration measurement with nonlinear converter in the presence of noise

    Science.gov (United States)

    Mozuras, Almantas

    2017-10-01

    Conventional vibration measurement methods use the linear properties of physical converters. These methods are strongly influenced by nonlinear distortions, because ideal linear converters are not available. Practically, any converter can be considered as a linear one, when an output signal is very small. However, the influence of noise increases significantly and signal-to-noise ratio decreases at lower signals. When the output signal is increasing, the nonlinear distortions are also augmenting. If the wide spectrum vibration is measured, conventional methods face a harmonic distortion as well as intermodulation effects. Purpose of this research is to develop a measurement method of wide spectrum vibration by using a converter described by a nonlinear function of type f(x), where x =x(t) denotes the dependence of coordinate x on time t due to the vibration. Parameter x(t) describing the vibration is expressed as Fourier series. The spectral components of the converter output f(x(t)) are determined by using Fourier transform. The obtained system of nonlinear equations is solved using the least squares technique that permits to find x(t) in the presence of noise. This method allows one to carry out the absolute or relative vibration measurements. High resistance to noise is typical for the absolute vibration measurement, but it is necessary to know the Taylor expansion coefficients of the function f(x). If the Taylor expansion is not known, the relative measurement of vibration parameters is also possible, but with lower resistance to noise. This method allows one to eliminate the influence of nonlinear distortions to the measurement results, and consequently to eliminate harmonic distortion and intermodulation effects. The use of nonlinear properties of the converter for measurement gives some advantages related to an increased frequency range of the output signal (consequently increasing the number of equations) that allows one to decrease the noise influence on

  17. Measurements of noise from rotary coal unloading operations

    International Nuclear Information System (INIS)

    Adams, T.S.; Bilello, M.A.

    1991-01-01

    In the licensing effort for a coal-fired power plant in the northeast United States, noise related to delivery and unloading of coal by train was identified as a significant concern to the nearby community. Specific issues included locomotive noise, the banging noises caused by railcar couplings during the start and stop cycles of the unloading operation, wheel squeal in the curves of the rail loop, and rotary coal unloader noises. This paper reports that a literature review provided adequate information on idling locomotive noise but very little on the other noise sources. Coupling impact noise was well documented for railcars actually being coupled at various speeds but not for coupled trains during start and stop operations. Wheel squeal was well documented by subway trains travelling at normal speeds, but nothing could be found for wheel squeal during very slow train movement as occurs during unloading. Similarly, adequate information was available for unenclosed rotary unloaders but not for enclosed unloaders. Consequently, actual noise measurements of a similar enclosed facility, and the associated train movements, were undertaken to obtain data more directly applicable to the planned facility

  18. Measurements of copper corrosion in the LOT Project at the Aespoe Hard Rock Laboratory

    International Nuclear Information System (INIS)

    Rosborg, B.; Karnland, O.; Quirk, G.; Werme, L.

    2003-01-01

    Real-time monitoring, of corrosion by means of electrochemical noise and other electrochemical techniques may offer interesting possibilities to estimate the kind and degree of corrosion in a sample or component, and further visualize the corrosion resistance of pure copper in repository environments. As a pilot effort, three cylindrical copper electrodes for such measurements, each of about 100 cm 2 surface area, have been installed in a test parcel in the Aespoe Hard Rock Laboratory and electrochemical measurements using InterCorr's SmartCET system were initiated in May 2001. The first results from real-time monitoring of copper corrosion in the Aespoe HRL under actual repository environment conditions by means of linear polarisation resistance, harmonic distortion analysis and electrochemical noise techniques are presented, and compared with the results obtained from one of the retrieved test parcels. (authors)

  19. Measuring the Noise Caused by Tehran Metro

    Directory of Open Access Journals (Sweden)

    Majid Abbas Pour

    1999-03-01

    Full Text Available One of the most common and important sources of noise in the residential environments are vehicles such as airplanes and subways. Trafficking of vehicles in streets and highways, psychologically, have damaging impacts on people living close to such areas. The development and expansion of the trading and industrial units is another factor that causes more and more exposure to noise.We have aimed at measuring the noises caused by vibration of subways of the Line of Karaj-Tehran-Mehrshahr and its effect on its surrounding area.To study this effect we designed a mathematical model and put the information of this subway line in the mentioned model. Then we analyzed the findings.This model demonstrated that we can control the harsh noise of the subway by reducing the speed of the train to 60Km/h in some points and increase in other parts to 130Km/h.

  20. Noise in position measurement by centroid calculation

    International Nuclear Information System (INIS)

    Volkov, P.

    1996-01-01

    The position of a particle trajectory in a gaseous (or semiconductor) detector can be measured by calculating the centroid of the induced charge on the cathode plane. The charge amplifiers attached to each cathode strip introduce noise which is added to the signal. This noise broadens the position resolution line. Our article gives an analytical tool to estimate the resolution broadening due to the noise per strip and the number of strips involved in the centroid calculation. It is shown that the position resolution increases faster than the square root of the number of strips involved. We also consider the consequence of added interstrip capacitors, intended to diminish the differential nonlinearity. It is shown that the position error increases slower than linearly with the interstrip capacities, due to the cancellation of correlated noise. The estimation we give, can be applied to calculations of position broadening other than the centroid finding. (orig.)

  1. Compressed Sensing with Linear Correlation Between Signal and Measurement Noise

    DEFF Research Database (Denmark)

    Arildsen, Thomas; Larsen, Torben

    2014-01-01

    reconstruction algorithms, but is not known in existing literature. The proposed technique reduces reconstruction error considerably in the case of linearly correlated measurements and noise. Numerical experiments confirm the efficacy of the technique. The technique is demonstrated with application to low......Existing convex relaxation-based approaches to reconstruction in compressed sensing assume that noise in the measurements is independent of the signal of interest. We consider the case of noise being linearly correlated with the signal and introduce a simple technique for improving compressed...... sensing reconstruction from such measurements. The technique is based on a linear model of the correlation of additive noise with the signal. The modification of the reconstruction algorithm based on this model is very simple and has negligible additional computational cost compared to standard...

  2. Cross correlation measurement of low frequency conductivity noise

    Science.gov (United States)

    Jain, Aditya Kumar; Nigudkar, Himanshu; Chakraborti, Himadri; Udupa, Aditi; Gupta, Kantimay Das

    2018-04-01

    In order to study the low frequency noise(1/f noise)an experimental technique based on cross correlation of two channels is presented. In this method the device under test (DUT)is connected to the two independently powered preamplifiers in parallel. The amplified signals from the two preamplifiers are fed to two channels of a digitizer. Subsequent data processing largelyeliminates the uncorrelated noise of the two channels. This method is tested for various commercial carbon/metal film resistors by measuring equilibrium thermal noise (4kBTR). The method is then modified to study the non-equilibrium low frequency noise of heterostructure samples using fiveprobe configuration. Five contact probes allow two parts of the sample to become two arms of a balanced bridge. This configuration helps in suppressing the effect of power supply fluctuations, bath temperature fluctuations and contact resistances.

  3. Measurements of effective noise temperature in fused silica fiber violin modes

    Energy Technology Data Exchange (ETDEWEB)

    Bilenko, I.A.; Lourie, S.L

    2002-11-25

    The results of measurements of the effective noise temperature in fused silica fiber violin modes are presented. In these measurements the fibers were stressed and value of the effective noise temperature was obtained by direct observation of oscillations in the fundamental violin modes of several samples. Measured values indicate that effective noise temperature does not exceed the room temperature significantly. This result is important for the design of the advanced gravitational wave antennae.

  4. Noise Measurements of the VAIIPR Fan

    Science.gov (United States)

    Mendoza, Jeff; Weir, Don

    2012-01-01

    This final report has been prepared by Honeywell Aerospace, Phoenix, Arizona, a unit of Honeywell International, Inc., documenting work performed during the period September 2004 through November 2005 for the National Aeronautics and Space Administration (NASA) Glenn Research Center, Cleveland, Ohio, under the Revolutionary Aero-Space Engine Research (RASER) Program, Contract No. NAS3- 01136, Task Order 6, Noise Measurements of the VAIIPR Fan. The NASA Task Manager was Dr. Joe Grady, NASA Glenn Research Center, Mail Code 60-6, Cleveland, Ohio 44135. The NASA Contract Officer was Mr. Albert Spence, NASA Glenn Research Center, Mail Code 60-6, Cleveland, Ohio 44135. This report focuses on the evaluation of internal fan noise as generated from various inflow disturbances based on measurements made from a circumferential array of sensors located near the fan and sensors upstream of a serpentine inlet.

  5. An excess noise measurement system for weak responsivity avalanche photodiodes

    Science.gov (United States)

    Qiao, Liang; Dimler, Simon J.; Baharuddin, Aina N. A. P.; Green, James E.; David, John P. R.

    2018-06-01

    A system for measuring, with reduced photocurrent, the excess noise associated with the gain in avalanche photodiodes (APDs), using a transimpedance amplifier front-end and based on phase-sensitive detection is described. The system can reliably measure the excess noise power of devices, even when the un-multiplied photocurrent is low (~10 nA). This is more than one order of magnitude better than previously reported systems and represents a significantly better noise signal to noise ratio. This improvement in performance has been achieved by increasing the value of the feedback resistor and reducing the op-amp bandwidth. The ability to characterise APD performance with such low photocurrents enables the use of low power light sources such as light emitting diode rather than lasers to investigate the APD noise performance.

  6. Evaluation of the susceptibility to pitting corrosion of steel api 5L x42 exposed to solutions containing chloride ions and CO{sub 2} by electrochemical noise measurements; Evaluacion de la susceptibilidad a la corrosion por picado del acero api 5l x42 expuesto a un ambiente con cloruros y CO{sub 2} mediante la tecnica de ruido electroquimico

    Energy Technology Data Exchange (ETDEWEB)

    Pena-Ballesteros, D.; Rodriguez-Vanegas, N.; Anteliz, C.; Sarmiento Klapper, H.

    2011-07-01

    The concentration of chloride ions and the partial pressure of CO{sub 2} play an important role in the degradation of low-carbon steels used for the construction of pipelines in oil and gas industry. In order to evaluate the susceptibility of carbon steel API 5L X42 to pitting corrosion electrochemical noise and linear polarization resistance measurements were carried out in aqueous solutions containing chloride ions and CO{sub 2}. The concentration of chloride ions was varied between, 10000 and 18000 ppm, and the CO{sub 2} partial pressure between 10 psi and 18 psi. Experimental results pointed out that the formation of protective layer, consisting mainly of FeCO{sub 3}, depends on the partial pressure of CO{sub 2} in the system. Nevertheless, the stability of this layer was considerably affected by increasing the concentration of chloride ions causing that localized corrosion has taken place in some areas of the surface of API 5L X42, which were detected by electrochemical noise technique. (Author) 10 refs.

  7. Extracting Earth's Elastic Wave Response from Noise Measurements

    Science.gov (United States)

    Snieder, Roel; Larose, Eric

    2013-05-01

    Recent research has shown that noise can be turned from a nuisance into a useful seismic source. In seismology and other fields in science and engineering, the estimation of the system response from noise measurements has proven to be a powerful technique. To convey the essence of the method, we first treat the simplest case of a homogeneous medium to show how noise measurements can be used to estimate waves that propagate between sensors. We provide an overview of physics research—dating back more than 100 years—showing that random field fluctuations contain information about the system response. This principle has found extensive use in surface-wave seismology but can also be applied to the estimation of body waves. Because noise provides continuous illumination of the subsurface, the extracted response is ideally suited for time-lapse monitoring. We present examples of time-lapse monitoring as applied to the softening of soil after the 2011 Tohoku-oki earthquake, the detection of a precursor to a landslide, and temporal changes in the lunar soil.

  8. Noise resistance applied to the study of zinc rich paints

    International Nuclear Information System (INIS)

    Espada Recarey, L.; Sanchez Bermudez, A.; Urrejola Madrinan, S.; Bouzada Alvela, F.

    2001-01-01

    Electrochemical Noise has been one of the more useful analysis methods to the study the corrosion processes due to the fact that it is simple and cheap. The objective of this work is to check the efficiency of this technique when it is applied to the study of Rich Zinc Paints and specifically the Noise Resistance parameter which is very efficiency to study metal-electrolyte systems. Then this technique was applied to Rich Zinc Paints systems of which we have already information by means of electrochemical impedance spectroscopy. The outcomes of this paper show the efficiency of applying Noise Resistance technique to explain the behavior of this kind of systems. (Author) 18 refs

  9. Kalman filtering techniques for reducing variance of digital speckle displacement measurement noise

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ Target dynamics are assumed to be known in measuring digital speckle displacement. Use is made of a simple measurement equation, where measurement noise represents the effect of disturbances introduced in measurement process. From these assumptions, Kalman filter can be designed to reduce variance of measurement noise. An optical and analysis system was set up, by which object motion with constant displacement and constant velocity is experimented with to verify validity of Kalman filtering techniques for reduction of measurement noise variance.

  10. Objective measures of listening effort: effects of background noise and noise reduction.

    Science.gov (United States)

    Sarampalis, Anastasios; Kalluri, Sridhar; Edwards, Brent; Hafter, Ervin

    2009-10-01

    This work is aimed at addressing a seeming contradiction related to the use of noise-reduction (NR) algorithms in hearing aids. The problem is that although some listeners claim a subjective improvement from NR, it has not been shown to improve speech intelligibility, often even making it worse. To address this, the hypothesis tested here is that the positive effects of NR might be to reduce cognitive effort directed toward speech reception, making it available for other tasks. Normal-hearing individuals participated in 2 dual-task experiments, in which 1 task was to report sentences or words in noise set to various signal-to-noise ratios. Secondary tasks involved either holding words in short-term memory or responding in a complex visual reaction-time task. At low values of signal-to-noise ratio, although NR had no positive effect on speech reception thresholds, it led to better performance on the word-memory task and quicker responses in visual reaction times. Results from both dual tasks support the hypothesis that NR reduces listening effort and frees up cognitive resources for other tasks. Future hearing aid research should incorporate objective measurements of cognitive benefits.

  11. Modeling of pH Dependent Electrochemical Noise in Ion Sensitive Field Effect Transistors ISFET

    OpenAIRE

    M. P. Das; M. Bhuyan

    2013-01-01

    pH ISFETs are very important sensor for in vivo continuous monitoring application of physiological and environmental system. The accuracy of Ion Sensitive Field Effect Transistor (ISFET) output measurement is greatly affected by the presences of noise, drift and slow response of the device. Although the noise analysis of ISFET so far performed in different literature relates only to sources originated from Field Effect Transistor (FET) structure which are almost constant for a particular devi...

  12. Pilot study of methods and equipment for in-home noise level measurements.

    Science.gov (United States)

    Neitzel, Richard L; Heikkinen, Maire S A; Williams, Christopher C; Viet, Susan Marie; Dellarco, Michael

    2015-01-15

    Knowledge of the auditory and non-auditory effects of noise has increased dramatically over the past decade, but indoor noise exposure measurement methods have not advanced appreciably, despite the introduction of applicable new technologies. This study evaluated various conventional and smart devices for exposure assessment in the National Children's Study. Three devices were tested: a sound level meter (SLM), a dosimeter, and a smart device with a noise measurement application installed. Instrument performance was evaluated in a series of semi-controlled tests in office environments over 96-hour periods, followed by measurements made continuously in two rooms (a child's bedroom and a most used room) in nine participating homes over a 7-day period with subsequent computation of a range of noise metrics. The SLMs and dosimeters yielded similar A-weighted average noise levels. Levels measured by the smart devices often differed substantially (showing both positive and negative bias, depending on the metric) from those measured via SLM and dosimeter, and demonstrated attenuation in some frequency bands in spectral analysis compared to SLM results. Virtually all measurements exceeded the Environmental Protection Agency's 45 dBA day-night limit for indoor residential exposures. The measurement protocol developed here can be employed in homes, demonstrates the possibility of measuring long-term noise exposures in homes with technologies beyond traditional SLMs, and highlights potential pitfalls associated with measurements made by smart devices.

  13. TRANSITIONS IN ELECTROCHEMICAL NOISE DURING PITTING CORROSION OF ALUMINUM IN CHLORIDE ENVIRONMENTS

    International Nuclear Information System (INIS)

    SASAKI, K.; ISAACS, H.S.; LEVY, P.W.

    2001-01-01

    Aluminum, in a chloride containing solutions close to its pitting potential, shows vigorous fluctuations in current and potential. Measurements have been made of the freely corroding potential, and the currents between interconnected electrodes. It is shown that there is a transition in the behavior of the transients. The transition occurs when multiple active pits are present and electrochemical communication occurs between them. The major source of current and potential transients is the growth process in the active pits rather than meta-stable pitting at the passive surface

  14. TRANSITIONS IN ELECTROCHEMICAL NOISE DURING PITTING CORROSION OF ALUMINUM IN CHLORIDE ENVIRONMENTS.

    Energy Technology Data Exchange (ETDEWEB)

    SASAKI,K.; ISAACS,H.S.; LEVY,P.W.

    2001-09-02

    Aluminum, in a chloride containing solutions close to its pitting potential, shows vigorous fluctuations in current and potential. Measurements have been made of the freely corroding potential, and the currents between interconnected electrodes. It is shown that there is a transition in the behavior of the transients. The transition occurs when multiple active pits are present and electrochemical communication occurs between them. The major source of current and potential transients is the growth process in the active pits rather than meta-stable pitting at the passive surface.

  15. The prediction of rotor rotational noise using measured fluctuating blade loads

    Science.gov (United States)

    Hosier, R. N.; Pegg, R. J.; Ramakrishnan, R.

    1974-01-01

    In tests conducted at the NASA Langley Research Center Helicopter Rotor Test Facility, simultaneous measurements of the high-frequency fluctuating aerodynamic blade loads and far-field radiated noise were made on a full-scale, nontranslating rotor system. After their characteristics were determined, the measured blade loads were used in an existing theory to predict the far-field rotational noise. A comparison of the calculated and measured rotational noise is presented with specific attention given to the effect of blade loading coefficients, chordwise loading distributions, blade loading phases, and observer azimuthal position on the predictions.

  16. Structure and electrochemical properties of copper wires with seamless 1D nanostructures

    Directory of Open Access Journals (Sweden)

    Yutong Wu

    2018-04-01

    Full Text Available A seamless Cu nanowire array grown on Cu wire is prepared by combining thermal oxidation method and electrochemical reduction. The data set described in this paper includes the structure of the Cu nanowires electrode, electrocatalytic active surface area, linear sweep voltammetry and amperometry measurement for nitrate sensing. The electrochemical data show that Cu nanowire arrays exhibited a linear response to nitrate ions over a concentration range from 50 μM to 600 μM (R2 = 0.9974 with a sensitivity of 0.357 μA μM−1 cm−1 and detection limit of 12.2 μM at a signal-to-noise ratio of 3, respectively.

  17. Noise measurements in 4 wind turbine farms

    International Nuclear Information System (INIS)

    Van Zuylen, E.J.; Koerts, M.

    1993-02-01

    The title wind turbine arrays are situated in Herbayum (Newinco 23PI250), Callantsoog (Bouma 160/20), Noordoostpolder (Windmaster WM300), and Ulketocht (Newinco 500 kW). Measurements were carried out by means of the so-called Ecofys Correlating Noise Meter to determine the source level of the wind turbines. The resulting source level as a function of the wind speed is interpolated to a source level for a wind speed of 8 m/s at 10 m height, on the basis of which the noise contours can be calculated. The noise contours are determined to analyze the noise load for people living in the neighbourhood of the wind parks. The source levels are compared with values as indicated in certificates, which are granted on the basis of a so-called Restricted Quality Certificate (BKC, abbreviated in Dutch) or the new standard NNI 6096/2 for the above-mentioned wind turbines. In general the results of this study agree quite well with the certified values. 12 figs., 7 tabs., 6 refs

  18. Correlation of Process Data and Electrochemical Noise to Assess Kraft Digester Corrosion: Kamloops Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, SJ

    2002-05-09

    Electrochemical noise (ECN) probes were deployed in a carbon steel continuous kraft digester at five locations roughly equi-spaced from top to bottom of the vessel. Current and potential noise, the temperature at each probe location, and the value of about 60 process parameters (flow rates, liquor chemistry, etc.) were monitored continuously for a period of one year. Historical vessel inspection data, including inspections accomplished immediately prior to and immediately following probe deployment, and post-test evaluation of the probe components were used to assess/compare corrosion indications from the probes with physical changes in wall thickness and corrosion patterns on the digester shell. The results indicate that furnish composition is a significant variable influencing digester corrosion, with increasing amounts of Douglas fir in the nominal furnish correlating directly with increased corrosion activity on the ECN probes. All five probes detected changes in furnish composition approximately simultaneously, indicating rapid chemical communication through the liquor, but the effect was strongest and persisted longest relatively high in the digester. The ECN probes also indicate significant corrosion activity occurred at each probe position during shutdown/restart transients. Little or no correlation between ECN probe corrosion activity and other operational variables was observed. Post-test evaluation of the probes confirmed general corrosion of a magnitude that closely agreed with corrosion current sums calculated for each probe over the exposure period and with historical average corrosion rates for the respective locations. Further, no pitting was observed on any of the electrodes, which is consistent with the ECN data, relevant polarization curves developed for steel in liquor removed from the digester, and the post-test inspection of the digester.

  19. A model for measurement of noise in CCD digital-video cameras

    International Nuclear Information System (INIS)

    Irie, K; Woodhead, I M; McKinnon, A E; Unsworth, K

    2008-01-01

    This study presents a comprehensive measurement of CCD digital-video camera noise. Knowledge of noise detail within images or video streams allows for the development of more sophisticated algorithms for separating true image content from the noise generated in an image sensor. The robustness and performance of an image-processing algorithm is fundamentally limited by sensor noise. The individual noise sources present in CCD sensors are well understood, but there has been little literature on the development of a complete noise model for CCD digital-video cameras, incorporating the effects of quantization and demosaicing

  20. Structureborne noise measurements on a small twin-engine aircraft

    Science.gov (United States)

    Cole, J. E., III; Martini, K. F.

    1988-01-01

    Structureborne noise measurements performed on a twin-engine aircraft (Beechcraft Baron) are reported. There are two overall objectives of the test program. The first is to obtain data to support the development of analytical models of the wing and fuselage, while the second is to evaluate effects of structural parameters on cabin noise. Measurements performed include structural and acoustic responses to impact excitation, structural and acoustic loss factors, and modal parameters of the wing. Path alterations include added mass to simulate fuel, variations in torque of bolts joining wing and fuselage, and increased acoustic absorption. Conclusions drawn regarding these measurements are presented.

  1. Detection of crevice corrosion in AISI type 316LN stainless steel in presence of pseudomonas bacteria using electrochemical noise technique

    International Nuclear Information System (INIS)

    Pujar, M.G.; George, R.P.; Ramya, S.; Kamachi Mudali, U.

    2011-01-01

    Gram-negative pseudomonas sp. was used as the test organism for the biofilm formation and growth on 316 LN stainless and electrochemical noise (EN) monitoring studies, since this genus has been identified as the major biofilm former on stainless steels. EN studies were conducted for 21 days on the galvanically coupled specimens exposed to the dilute nutrient culture with pseudomonas sp. The visual records of the current potential EN, analysis of statistical and power spectral density (PSD) parameters of current and potential along with shot-noise parameters showed increase in the localized corrosion during initial 2-11 days exposure; thereafter the specimens showed passive behaviour. Raman spectra taken inside the pit for the specimen exposed for 21 days showed the peak corresponding to Cr 3+ ions signifying repassivation process. Similarly, Raman spectra on the surface outside the pits on the specimens exposed for 7, 10 and 15 days showed steady growth of the peak corresponding to Cr 3+ ions. This implied steady enrichment of Cr on the surface of the specimen which accounted for the gradual passivation with increased exposure time. (author)

  2. Measuring Variability in the Presence of Noise

    Science.gov (United States)

    Welsh, W. F.

    Quantitative measurements of a variable signal in the presence of noise requires very careful attention to subtle affects which can easily bias the measurements. This is not limited to the low-count rate regime, nor is the bias error necessarily small. In this talk I will mention some of the dangers in applying standard techniques which are appropriate for high signal to noise data but fail in the cases where the S/N is low. I will discuss methods for correcting the bias in the these cases, both for periodic and non-periodic variability, and will introduce the concept of the ``filtered de-biased RMS''. I will also illustrate some common abuses of power spectrum interpretation. All of these points will be illustrated with examples from recent work on CV and AGN variability.

  3. Validation of an Aero-Acoustic Wind Turbine Noise Model Using Advanced Noise Source Measurements of a 500kW Turbine

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Fischer, Andreas

    2016-01-01

    rotor noise model is presented. It includes the main sources of aeroacoustic noise from wind turbines: turbulent inflow, trailing edge and stall noise. The noise measured by one microphone located directly downstream of the wind turbine is compared to the model predictions at the microphone location....... A good qualitative agreement is found. When wind speed increases, the rotor noise model shows that at high frequencies the stall noise becomes dominant. It also shows that turbulent inflow noise is dominant at low frequencies for all wind speeds and that trailing edge noise is dominant at low wind speeds...

  4. Passive coherent discriminator using phase diversity for the simultaneous measurement of frequency noise and intensity noise of a continuous-wave laser

    Science.gov (United States)

    Michaud-Belleau, V.; Bergeron, H.; Light, P. S.; Hébert, N. B.; Deschênes, J. D.; Luiten, A. N.; Genest, J.

    2016-10-01

    The frequency noise and intensity noise of a laser set the performance limits in many modern photonics applications and, consequently, must often be characterized. As lasers continue to improve, the measurement of these noises however becomes increasingly challenging. Current approaches for the characterization of very high-performance lasers often call for a second laser with equal or higher performance to the one that is to be measured, an incoherent interferometer having an extremely long delay-arm, or an interferometer that relies on an active device. These instrumental features can be impractical or problematic under certain experimental conditions. As an alternative, this paper presents an entirely passive coherent interferometer that employs an optical 90° hybrid coupler to perform in-phase and quadrature detection. We demonstrate the technique by measuring the frequency noise power spectral density of a highly-stable 192 THz (1560 nm) fiber laser over five frequency decades. Simultaneously, we are able to measure its relative intensity noise power spectral density and characterize the correlation between its amplitude noise and phase noise. We correct some common misconceptions through a detailed theoretical analysis and demonstrate the necessity to account for normal imperfections of the optical 90° hybrid coupler. We finally conclude that this passive coherent discriminator is suitable for reliable and simple noise characterization of highly-stable lasers, with bandwidth and dynamic range benefits but susceptibility to additive noise contamination.

  5. Robust shot-noise measurement for continuous-variable quantum key distribution

    Science.gov (United States)

    Kunz-Jacques, Sébastien; Jouguet, Paul

    2015-02-01

    We study a practical method to measure the shot noise in real time in continuous-variable quantum key distribution systems. The amount of secret key that can be extracted from the raw statistics depends strongly on this quantity since it affects in particular the computation of the excess noise (i.e., noise in excess of the shot noise) added by an eavesdropper on the quantum channel. Some powerful quantum hacking attacks relying on faking the estimated value of the shot noise to hide an intercept and resend strategy were proposed. Here, we provide experimental evidence that our method can defeat the saturation attack and the wavelength attack.

  6. Portable Lock-in Amplifier-Based Electrochemical Method to Measure an Array of 64 Sensors for Point-of-Care Applications.

    Science.gov (United States)

    Hrdý, Radim; Kynclová, Hana; Klepáčová, Ivana; Bartošík, Martin; Neužil, Pavel

    2017-09-05

    We present a portable lock-in amplifier-based electrochemical sensing system. The basic unit (cluster) consists of four electrochemical cells (EC), each containing one pseudoreference electrode (PRE) and one working electrode (WE). All four ECs are simultaneously interrogated, each at different frequencies, with square wave pulses superposed on a sawtooth signal for cyclic voltammetry (CV). Lock-in amplification provides independent read-out of four signals, with excellent noise suppression. We expanded a single cluster system into an array of 16 clusters by using electronic switches. The chip with an array of ECs was fabricated using planar technology with a gap between a WE and a PRE of ≈2 μm, which results in partial microelectrode-type behavior. The basic electrode characterization was performed with the model case using a ferricyanide-ferrocyanide redox couple (Fe 2+ /Fe 3+ ) reaction, performing CV and differential pulse voltammetry (DPV). We then used this system to perform cyclic lock-in voltammetry (CLV) to measure concurrently responses of the four ECs. We repeated this method with all 64 ECs on the chip. The standard deviation of a peak oxidation and reduction current in a single channel consisting of 13 ECs was ≈7.46% and ≈5.6%, respectively. The four-EC configuration in each measured spot allows determination of nonperforming ECs and, thus, to eliminate potential false results. This system is built in a portable palm-size format suitable for point-of-care applications. It can perform either individual or multiple measurements of active compounds, such as biomarkers.

  7. Using Smart Devices to Measure Intermittent Noise in the Workplace

    Directory of Open Access Journals (Sweden)

    Benjamin Roberts

    2017-01-01

    Full Text Available Purpose: To determine the accuracy of smart devices (iPods to measure intermittent noise and integrate a noise dose in the workplace. Materials and Methods: In experiment 1, four iPods were each paired with a Larson Davis Spark dosimeter and exposed to randomly fluctuating pink noise in a reverberant sound chamber. Descriptive statistics and the mean difference between the iPod and its paired dosimeter were calculated for the 1-s data logged measurements. The calculated time weighted average (TWA was also compared between the devices. In experiment 2, 15 maintenance workers and 14 office workers wore an iPod and dosimeter during their work-shift for a maximum of five workdays. A mixed effects linear regression model was used to control for repeated measures and to determine the effect of the device type on the projected 8-h TWA. Results: In experiment 1, a total of 315,306 1-s data logged measurements were made. The interquartile range of the mean difference fell within ±2.0 A-weighted decibels (dBA, which is the standard used by the American National Standards Institute to classify a type 2 sound level meter. The mean difference of the calculated TWA was within ±0.5 dBA except for one outlier. In experiment 2, the results of the mixed effects model found that, on average, iPods measured an 8-h TWA 1.7 dBA higher than their paired dosimeters. Conclusion: This study shows that iPods have the ability to make reasonably accurate noise measurements in the workplace, but they are not as accurate as traditional noise dosimeters.

  8. What Do Contrast Threshold Equivalent Noise Studies Actually Measure? Noise vs. Nonlinearity in Different Masking Paradigms.

    Directory of Open Access Journals (Sweden)

    Alex S Baldwin

    Full Text Available The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system's input has on its output one can estimate the variance of this internal noise. By applying this simple "linear amplifier" model to the human visual system, one can entirely explain an observer's detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system's internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity. Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF. We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies.

  9. Measurement of Acceptable Noise Level with Background Music.

    Science.gov (United States)

    Ahn, Hyun-Jung; Bahng, Junghwa; Lee, Jae Hee

    2015-09-01

    Acceptable noise level (ANL) is a measure of the maximum background noise level (BNL) that a person is willing to tolerate while following a target story. Although researchers have used various sources of target sound in ANL measures, a limited type of background noise has been used. Extending the previous study of Gordon-Hickey & Moore (2007), the current study determined the effect of music genre and tempo on ANLs as possible factors affecting ANLs. We also investigated the relationships between individual ANLs and the familiarity of music samples and between music ANLs and subjective preference. Forty-one participants were seperated into two groups according to their ANLs, 29 low-ANL listeners and 12 high-ANL listeners. Using Korean ANL material, the individual ANLs were measured based on the listeners' most comfortable listening level and BNL. The ANLs were measured in six conditions, with different music tempo (fast, slow) and genre (K-pop, pop, classical) in a counterbalanced order. Overall, ANLs did not differ by the tempo of background music, but music genre significantly affected individual ANLs. We observed relatively higher ANLs with K-pop music and relatively lower ANLs with classical music. This tendency was similar in both low-ANL and high-ANL groups. However, the subjective ratings of music familiarity and preference affected ANLs differently for low-ANL and high-ANL groups. In contrast to the low-ANL listeners, the ANLs of the high-ANL listeners were significantly affected by music familiarity and preference. The genre of background music affected ANLs obtained using background music. The degree of music familiarity and preference appears to be associated with individual susceptibility to background music only for listeners who are greatly annoyed by background noise (high-ANL listeners).

  10. Measuring the background acoustic noise in the BN-600 steam generator

    International Nuclear Information System (INIS)

    Yugaj, V.S.; Zhukovets, V.N.; Ivannikov, V.I.; Vylomov, V.V.; Ryabinin, F.; Chernykh, P.G.; Flejsher, Yu.V.

    1987-01-01

    Acoustic noises in the lower chambers of evaporation and intermediate overheating moduli of the BN-600 reactor steam generator are measured. Bachground noises are registered in the whole range of frequencies studied, from 0.63 to 160 kHz. The comparison of noise spectra in evaporator and overheater has revealed a certain difference. However the general tendency is the reduction of the noise level at high frequencies > 8 kHz. The increase of the noise level at low steam content is observed only in a narrow of frequency range of 3-6 kHz

  11. Automated measurement of CT noise in patient images with a novel structure coherence feature

    International Nuclear Information System (INIS)

    Chun, Minsoo; Kim, Jong Hyo; Choi, Young Hun

    2015-01-01

    While the assessment of CT noise constitutes an important task for the optimization of scan protocols in clinical routine, the majority of noise measurements in practice still rely on manual operation, hence limiting their efficiency and reliability. This study presents an algorithm for the automated measurement of CT noise in patient images with a novel structure coherence feature. The proposed algorithm consists of a four-step procedure including subcutaneous fat tissue selection, the calculation of structure coherence feature, the determination of homogeneous ROIs, and the estimation of the average noise level. In an evaluation with 94 CT scans (16 517 images) of pediatric and adult patients along with the participation of two radiologists, ROIs were placed on a homogeneous fat region at 99.46% accuracy, and the agreement of the automated noise measurements with the radiologists’ reference noise measurements (PCC  =  0.86) was substantially higher than the within and between-rater agreements of noise measurements (PCC within   =  0.75, PCC between   =  0.70). In addition, the absolute noise level measurements matched closely the theoretical noise levels generated by a reduced-dose simulation technique. Our proposed algorithm has the potential to be used for examining the appropriateness of radiation dose and the image quality of CT protocols for research purposes as well as clinical routine. (paper)

  12. The systematic error of temperature noise correlation measurement method and self-calibration

    International Nuclear Information System (INIS)

    Tian Hong; Tong Yunxian

    1993-04-01

    The turbulent transport behavior of fluid noise and the nature of noise affect on the velocity measurement system have been studied. The systematic error of velocity measurement system is analyzed. A theoretical calibration method is proposed, which makes the velocity measurement of time-correlation as an absolute measurement method. The theoretical results are in good agreement with experiments

  13. Vibration Noise Modeling for Measurement While Drilling System Based on FOGs

    Directory of Open Access Journals (Sweden)

    Chunxi Zhang

    2017-10-01

    Full Text Available Aiming to improve survey accuracy of Measurement While Drilling (MWD based on Fiber Optic Gyroscopes (FOGs in the long period, the external aiding sources are fused into the inertial navigation by the Kalman filter (KF method. The KF method needs to model the inertial sensors’ noise as the system noise model. The system noise is modeled as white Gaussian noise conventionally. However, because of the vibration while drilling, the noise in gyros isn’t white Gaussian noise any more. Moreover, an incorrect noise model will degrade the accuracy of KF. This paper developed a new approach for noise modeling on the basis of dynamic Allan variance (DAVAR. In contrast to conventional white noise models, the new noise model contains both the white noise and the color noise. With this new noise model, the KF for the MWD was designed. Finally, two vibration experiments have been performed. Experimental results showed that the proposed vibration noise modeling approach significantly improved the estimated accuracies of the inertial sensor drifts. Compared the navigation results based on different noise model, with the DAVAR noise model, the position error and the toolface angle error are reduced more than 90%. The velocity error is reduced more than 65%. The azimuth error is reduced more than 50%.

  14. Vibration Noise Modeling for Measurement While Drilling System Based on FOGs.

    Science.gov (United States)

    Zhang, Chunxi; Wang, Lu; Gao, Shuang; Lin, Tie; Li, Xianmu

    2017-10-17

    Aiming to improve survey accuracy of Measurement While Drilling (MWD) based on Fiber Optic Gyroscopes (FOGs) in the long period, the external aiding sources are fused into the inertial navigation by the Kalman filter (KF) method. The KF method needs to model the inertial sensors' noise as the system noise model. The system noise is modeled as white Gaussian noise conventionally. However, because of the vibration while drilling, the noise in gyros isn't white Gaussian noise any more. Moreover, an incorrect noise model will degrade the accuracy of KF. This paper developed a new approach for noise modeling on the basis of dynamic Allan variance (DAVAR). In contrast to conventional white noise models, the new noise model contains both the white noise and the color noise. With this new noise model, the KF for the MWD was designed. Finally, two vibration experiments have been performed. Experimental results showed that the proposed vibration noise modeling approach significantly improved the estimated accuracies of the inertial sensor drifts. Compared the navigation results based on different noise model, with the DAVAR noise model, the position error and the toolface angle error are reduced more than 90%. The velocity error is reduced more than 65%. The azimuth error is reduced more than 50%.

  15. Measurement of quantum noise in a single-electron transistor near the quantum limit

    Science.gov (United States)

    Xue, W. W.; Ji, Z.; Pan, Feng; Stettenheim, Joel; Blencowe, M. P.; Rimberg, A. J.

    2009-09-01

    Quantum measurement has challenged physicists for almost a century. Classically, there is no lower bound on the noise a measurement may add. Quantum mechanically, however, measuring a system necessarily perturbs it. When applied to electrical amplifiers, this means that improved sensitivity requires increased backaction that itself contributes noise. The result is a strict quantum limit on added amplifier noise. To approach this limit, a quantum-limited amplifier must possess an ideal balance between sensitivity and backaction; furthermore, its noise must dominate that of subsequent classical amplifiers. Here, we report the first complete and quantitative measurement of the quantum noise of a superconducting single-electron transistor (S-SET) near a double Cooper-pair resonance predicted to have the right combination of sensitivity and backaction. A simultaneous measurement of our S-SET's charge sensitivity indicates that it operates within a factor of 3.6 of the quantum limit, a fourfold improvement over the nearest comparable results.

  16. ARMA modelling of neutron stochastic processes with large measurement noise

    International Nuclear Information System (INIS)

    Zavaljevski, N.; Kostic, Lj.; Pesic, M.

    1994-01-01

    An autoregressive moving average (ARMA) model of the neutron fluctuations with large measurement noise is derived from langevin stochastic equations and validated using time series data obtained during prompt neutron decay constant measurements at the zero power reactor RB in Vinca. Model parameters are estimated using the maximum likelihood (ML) off-line algorithm and an adaptive pole estimation algorithm based on the recursive prediction error method (RPE). The results show that subcriticality can be determined from real data with high measurement noise using much shorter statistical sample than in standard methods. (author)

  17. Residual phase noise measurements of the input section in a receiver

    International Nuclear Information System (INIS)

    Mavric, Uros; Chase, Brian; Fermilab

    2007-01-01

    If not designed properly, the input section of an analog down-converter can introduce phase noise that can prevail over other noise sources in the system. In the paper we present residual phase noise measurements of a simplified input section of a classical receiver that is composed of various commercially available mixers and driven by an LO amplifier

  18. Flow measurements using noise signals of axially displaced thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Kozma, R.; Hoogenboom, J.E. (Interuniversitair Reactor Inst., Delft (Netherlands))

    1990-01-01

    Determination of the flow rate of the coolant in the cooling channels of nuclear reactors is an important aspect of core monitoring. It is usually impossible to measure the flow by flowmeters in the individual channels due to the lack of space and safety reasons. An alternative method is based on the analysis of noise signals of the available in-core detectors. In such a noise method, a transit time which characterises the propagation of thermohydraulic fluctuations (density or temperature fluctuations) in the coolant is determined from the correlation between the noise signals of axially displaced detectors. In this paper, the results of flow measurements using axially displaced thermocouples in the channel wall will be presented. The experiments have been performed in a simulated MRT-type fuel assembly located in the research reactor HOR of the Interfaculty Reactor Institute, Delft. It was found that the velocities obtained via temperature noise correlation methods are significantly larger than the area-averaged velocity in the single-phase coolant flow. Model calculations show that the observed phenomenon can be explained by effects due to the radial velocity distribution in the channel. (author).

  19. Measurement of tonal-noise characteristics and periodic flow structure around NACA0018 airfoil

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, T.; Fujisawa, N. [Niigata University, Department Mechanical Engineering, Niigata (Japan); Lee, S. [Inha University, Department Mechanical Engineering, Incheon (Korea)

    2006-03-15

    The characteristics of tonal noise and the variations of flow structure around NACA0018 airfoil in a uniform flow are studied by means of simultaneous measurement of noise and velocity field by particle-image velocimetry to understand the generation mechanism of tonal noise. Measurements are made on the noise characteristics, the phase-averaged velocity field with respect to the noise signal, and the cross-correlation contour of velocity fluctuations and noise signal. These experimental results indicate that the tonal noise is generated from the periodic vortex structure on the pressure surface of the airfoil near the trailing edge of the airfoil. It is found that the vortex structure is highly correlated with the noise signal, which indicates the presence of noise-source distribution on the pressure surface. The vorticity distribution on the pressure surface breaks down near the trailing edge of the airfoil and forms a staggered vortex street in the wake of the airfoil. (orig.)

  20. Joseph F. Keithley Award For Advances in Measurement Science Talk: Precision Noise Measurements at Microwave and Optical Frequencies

    Science.gov (United States)

    Ivanov, Eugene

    2010-03-01

    The quest to detect Gravitational Waves resulted in a number of important developments in the fields of oscillator frequency stabilization and precision noise measurements. This was due to the realization of similarities between the principles of high sensitivity measurements of weak mechanical forces and phase/amplitude fluctuations of microwave signals. In both cases interferometric carrier suppression and low-noise amplification of the residual noise sidebands were the main factors behind significant improvements in the resolution of spectral measurements. In particular, microwave frequency discriminators with almost thermal noise limited sensitivity were constructed leading to microwave oscillators with more than 25dB lower phase noise than the previous state-of-the-art. High power solid-state microwave amplifiers offered further opportunity of oscillator phase noise reduction due to the increased energy stored in the high-Q resonator of the frequency discriminator. High power microwave oscillators with the phase noise spectral density close to -160dBc/Hz at 1kHz Fourier frequency have been recently demonstrated. The principles of interferometric signal processing have been applied to the study of noise phenomena in microwave components which were considered to be ``noise free''. This resulted in the first experimental evidence of phase fluctuations in microwave circulators. More efficient use of signal power enabled construction of the ``power recycled'' interferometers with spectral resolution of -200dBc/Hz at 1kHz Fourier frequency. This has been lately superseded by an order of magnitude with a waveguide interferometer due to its higher power recycling factor. A number of opto-electronic measurement systems were developed to characterize the fidelity of frequency transfer from the optical to the microwave domain. This included a new type of a phase detector capable of measuring phase fluctuations of the weak microwave signals extracted from the demodulated

  1. Measuring proton beam thermal noises on the NAP-M storage ring

    International Nuclear Information System (INIS)

    Dement'ev, E.N.; Dikanskij, N.S.; Medvedko, A.S.; Parkhomchuk, V.V.; Pestrikov, D.V.

    1980-01-01

    The data on experimental investigation of thermal noises of an asimuthally homogeneous proton beam on the NAP-M storage ring are given. The noise spectra are measured at the 5th and 8th harmonics of the ciculation frequency using pick-up electrodes. The dependencies of the noise power on the proton current for noncooled and cooled beams are presented. It is shown that as a result of electron cooling the noise power decreases by two orders and in the 0.5-10 μA current range the noise power of the cooled beam does not depend on the proton current. The noise power of the noncooled beam linearly increases with the proton current. It is also shown that with the modulation growth the noise power increases. The conclusions are made that while analyzing noises of the continuous beam in the storage ring the changes of the noise spectra due to particle interaction in the beam should be taken into account

  2. Expert group study on recommended practices for wind turbine testing and evaluation. 10. Measurement of noise immission from wind turbines at noise receptor locations

    International Nuclear Information System (INIS)

    Ljunggren, S.

    1997-01-01

    The purpose of this guide is to provide a set of techniques and methods for the measurement and description of wind turbine noise immission, that is, wind turbine noise at receptor locations. These techniques and methods have been prepared so that they can be used by: manufacturers; developers; operators; planning authorities; research and development engineers, for the purpose of verification of compliance with noise immission limits and of noise propagation models. The measurement of noise immission from wind turbines is a complex acoustic task. This guideline cannot cover all possible problems that may be encountered on, for instance: determination of wind speed; measurements in cases of low signal-to-noise ratio; allowance for reflections from buildings. Thus, it is strongly recommended that the measurements described in this guide are always carried out by experienced acousticians. (au)

  3. Boundary layer measurements of the NACA0015 and implications for noise modeling

    Energy Technology Data Exchange (ETDEWEB)

    Bertagnolio, F.

    2011-01-15

    A NACA0015 airfoil section instrumented with an array of high frequency microphones flush-mounted beneath its surface was measured in the wind tunnel at LM Wind Power in Lunderskov. Various inflow speeds and angles of attack were investigated. In addition, a hot-wire device system was used to measure the velocity profiles and turbulence characteristics in the boundary layer near the trailing edge of the airfoil. The measured boundary layer data are presented in this report and compared with CFD results. A relative good agreement is observed, though a few discrepancies also appear. Comparisons of surface pressure fluctuations spectra are used to analyze and improve trailing edge noise modeling by the so-called TNO model. Finally, a pair of hot-wires were placed on each side of the trailing edge in order to measure the radiated trailing edge noise. However, there is no strong evidence that such noise could be measured in the higher frequency range. Nevertheless, low-frequency noise could be measured and related to the presence of the airfoil but its origin is unclear. (Author)

  4. Noise Measurements of High Aspect Ratio Distributed Exhaust Systems

    Science.gov (United States)

    Bridges, James E.

    2015-01-01

    This paper covers far-field acoustic measurements of a family of rectangular nozzles with aspect ratio 8, in the high subsonic flow regime. Several variations of nozzle geometry, commonly found in embedded exhaust systems, are explored, including bevels, slants, single broad chevrons and notches, and internal septae. Far-field acoustic results, presented previously for the simple rectangular nozzle, showed that increasing aspect ratio increases the high frequency noise, especially directed in the plane containing the minor axis of the nozzle. Detailed changes to the nozzle geometry generally made little difference in the noise, and the differences were greatest at low speed. Having an extended lip on one broad side (bevel) did produce up to 3 decibels more noise in all directions, while extending the lip on the narrow side (slant) produced up to 2 decibels more noise, primarily on the side with the extension. Adding a single, non-intrusive chevron, made no significant change to the noise, while inverting the chevron (notch) produced up to 2decibels increase in the noise. Having internal walls (septae) within the nozzle, such as would be required for structural support or when multiple fan ducts are aggregated, reduced the noise of the rectangular jet, but could produce a highly directional shedding tone from the septae trailing edges. Finally, a nozzle with both septae and a beveled nozzle, representative of the exhaust system envisioned for a distributed electric propulsion aircraft with a common rectangular duct, produced almost as much noise as the beveled nozzle, with the septae not contributing much reduction in noise.

  5. Application of a Beamforming Technique to the Measurement of Airfoil Leading Edge Noise

    Directory of Open Access Journals (Sweden)

    Thomas Geyer

    2012-01-01

    Full Text Available The present paper describes the use of microphone array technology and beamforming algorithms for the measurement and analysis of noise generated by the interaction of a turbulent flow with the leading edge of an airfoil. Experiments were performed using a setup in an aeroacoustic wind tunnel, where the turbulent inflow is provided by different grids. In order to exactly localize the aeroacoustic noise sources and, moreover, to separate airfoil leading edge noise from grid-generated noise, the selected deconvolution beamforming algorithm is extended to be used on a fully three-dimensional source region. The result of this extended beamforming are three-dimensional mappings of noise source locations. Besides acoustic measurements, the investigation of airfoil leading edge noise requires the measurement of parameters describing the incident turbulence, such as the intensity and a characteristic length scale or time scale. The method used for the determination of these parameters in the present study is explained in detail. To demonstrate the applicability of the extended beamforming algorithm and the experimental setup as a whole, the noise generated at the leading edge of airfoils made of porous materials was measured and compared to that generated at the leading edge of a common nonporous airfoil.

  6. Phase Noise and Intensity Noise of the Pulse Train Generated from Mode-locked Lasers in the Demodulation Measurement

    OpenAIRE

    Wu, Kan; Shum, Ping

    2010-01-01

    The phase noise and intensity noise of a pulse train are theoretically analyzed in the demodulation measurement. The effect of pulse asymmetry is discussed for the first time using Fourier series. Experimentally, photodetectors with different bandwidth and incident power levels are compared to achieve minimum pulse distortion.

  7. A compact microelectrode array chip with multiple measuring sites for electrochemical applications

    DEFF Research Database (Denmark)

    Dimaki, Maria; Vergani, Marco; Heiskanen, Arto

    2014-01-01

    In this paper we demonstrate the fabrication and electrochemical characterization of a microchip with 12 identical but individually addressable electrochemical measuring sites, each consisting of a set of interdigitated electrodes acting as a working electrode as well as two circular electrodes...... functioning as a counter and reference electrode in close proximity. The electrodes are made of gold on a silicon oxide substrate and are passivated by a silicon nitride membrane. A method for avoiding the creation of high edges at the electrodes (known as lift-off ears) is presented. The microchip design...

  8. Automated system for noise-measurements on low-ohmic samples and magnetic sensors

    NARCIS (Netherlands)

    Jonker, R.J.W.; Briaire, J.; Vandamme, L.K.J.

    1999-01-01

    An automated system for electronic noise measurements on metal films is presented. This new system, controlled by a personal computer which utilizes National Instruments' LabVIEW software, is designed to measure low frequency noise as a function of an externally imposed magnetic field and as a

  9. A transimpedance amplifier for excess noise measurements of high junction capacitance avalanche photodiodes

    International Nuclear Information System (INIS)

    Green, James E; David, John P R; Tozer, Richard C

    2012-01-01

    This paper reports a novel and versatile system for measuring excess noise and multiplication in avalanche photodiodes (APDs), using a bipolar junction transistor based transimpedance amplifier front-end and based on phase-sensitive detection, which permits accurate measurement in the presence of a high dark current. The system can reliably measure the excess noise factor of devices with capacitance up to 5 nF. This system has been used to measure thin, large area Si pin APDs and the resulting data are in good agreement with measurements of the same devices obtained from a different noise measurement system which will be reported separately. (paper)

  10. Measurement of the Low Frequency Noise of MOSFETs under Large Signal RF Excitation

    NARCIS (Netherlands)

    van der Wel, A.P.; Klumperink, Eric A.M.; Nauta, Bram

    2002-01-01

    A measurement technique [1] is presented that allows measurement of MOSFET low frequency (LF) noise under large signal RF (Radio Frequency) excitation. Measurements indicate that MOSFETS exhibit a reduction in LF noise when they are cycled from inversion to accummulation and that this reduction does

  11. The construction of a magnetite electrode for measurement of the electrochemical property

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myongjin; Kim, Hong Pyo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    Flow accelerated corrosion (FAC) causes severe damage to secondary piping systems. An accident from FAC occurred at the Oyster Creek nuclear power plant (NPP) in 1978. Other NPPs such as Surry 2 and Mihama 3 have also experienced an FAC that induced damage to the carbon steel piping. FAC is influenced by many factors such as the water chemistry (temperature, pH, dissolved oxygen (D. O.) in a solution, and etc.), chemical composition of carbon steel, and fluid dynamics. Magnetite is formed at the inner surface of carbon steel, and protects the integrity of pipes from damage. The magnetite has a stable state at each equilibrium condition, so that it can be dissolved into the fluid under conditions that satisfy the equilibrium state. The iron solubility can be calculated by considering the reaction equilibrium constants for prediction of the change in the magnetite layer. On the other hand, it is necessary to measure the experimental solubility to compare the theoretical data and the experimental data. In addition, the solubility of magnetite can be predicted by measuring the electrochemical experiments. However, there are few studies related to the electrochemical property of magnetite owing to the difficulty of the electrode fabrication. In the present work, a magnetite electrode was prepared using a dipping method, and the electrochemical property of the magnetite electrode was measured in an alkaline solution.

  12. Experimental Test of Entropic Noise-Disturbance Uncertainty Relations for Spin-1/2 Measurements.

    Science.gov (United States)

    Sulyok, Georg; Sponar, Stephan; Demirel, Bülent; Buscemi, Francesco; Hall, Michael J W; Ozawa, Masanao; Hasegawa, Yuji

    2015-07-17

    Information-theoretic definitions for noise and disturbance in quantum measurements were given in [Phys. Rev. Lett. 112, 050401 (2014)] and a state-independent noise-disturbance uncertainty relation was obtained. Here, we derive a tight noise-disturbance uncertainty relation for complementary qubit observables and carry out an experimental test. Successive projective measurements on the neutron's spin-1/2 system, together with a correction procedure which reduces the disturbance, are performed. Our experimental results saturate the tight noise-disturbance uncertainty relation for qubits when an optimal correction procedure is applied.

  13. Noise Measurement and Frequency Analysis of Commercially Available Noisy Toys

    Directory of Open Access Journals (Sweden)

    Shohreh Jalaie

    2005-06-01

    Full Text Available Objective: Noise measurement and frequency analysis of commercially available noisy toys were the main purposes of the study. Materials and Methods: 181 noisy toys commonly found in toy stores in different zones of Tehran were selected and categorized into 10 groups. Noise measurement were done at 2, 25, and 50 cm from toys in dBA. The noisiest toy of each group was frequency analyzed in octave bands. Results: The highest and the lowest intensity levels belonged to the gun (mean=112 dBA and range of 100-127 dBA and to the rattle-box (mean=84 dBA and range of 74-95 dBA, respectively. Noise intensity levels significantly decreased with increasing distance except for two toys. Noise frequency analysis indicated energy in effective hearing frequencies. Most of the toys energies were in the middle and high frequency region. Conclusion: As intensity level of the toys is considerable, mostly more than 90 dBA, and also their energy exist in the middle and high frequency region, toys should be considered as a cause of the hearing impairment.

  14. A Baseband Ultra-Low Noise SiGe:C BiCMOS 0.25 µm Amplifier And Its Application For An On-Chip Phase-Noise Measurement Circuit

    OpenAIRE

    Godet , Sylvain; Tournier , Éric; Llopis , Olivier; Cathelin , Andreia; Juyon , Julien

    2009-01-01

    4 pages; International audience; The design and realization of an ultra-low noise operational amplifier is presented. Its applications are integrated low-frequency noise measurements in electronic devices and on-chip phase-noise measurement circuit. This paper discusses the SiGe:C BiCMOS 0.25 µm design improvements used for low noise applications. The proposed three-stage operational amplifier uses parallel bipolar transistor connection as input differential pair for low noise behavior. This ...

  15. Phase noise measurements with a cryogenic power-splitter to minimize the cross-spectral collapse effect

    Science.gov (United States)

    Hati, Archita; Nelson, Craig W.; Pappas, David P.; Howe, David A.

    2017-11-01

    The cross-spectrum noise measurement technique enables enhanced resolution of spectral measurements. However, it has disadvantages, namely, increased complexity, inability of making real-time measurements, and bias due to the "cross-spectral collapse" (CSC) effect. The CSC can occur when the spectral density of a random process under investigation approaches the thermal noise of the power splitter. This effect can severely bias results due to a differential measurement between the investigated noise and the anti-correlated (phase-inverted) noise of the power splitter. In this paper, we report an accurate measurement of the phase noise of a thermally limited electronic oscillator operating at room temperature (300 K) without significant CSC bias. We mitigated the problem by cooling the power splitter to liquid helium temperature (4 K). We quantify errors of greater than 1 dB that occur when the thermal noise of the oscillator at room temperature is measured with the power splitter at temperatures above 77 K.

  16. Noise measurement at wind power plants; Geraeuschmessung an Windenergieanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Schoene, Ralph [Cirrus Research plc, Frankfurt am Main (Germany)

    2012-09-15

    Wind energy is a supporting pillar of the energy transition. For further expansion, it is important to reduce prejudices, for example by measurements as precise as possible and assessments of the often unobjectively discussed noise emissions. These measurements are based on instruments which can analyze and measure low-frequency sound.

  17. Neutron noise measurements at the Delphi subcritical assembly

    International Nuclear Information System (INIS)

    Szieberth, M.; Klujber, G.; Kloosterman, J. L.; De Haas, D.

    2012-01-01

    The paper presents the results and evaluations of a comprehensive set of neutron noise measurements on the Delphi subcritical assembly of the Delft Univ. of Technology. The measurements investigated the effect of different source distributions (inherent spontaneous fission and 252 Cf) and the position of the detectors applied (both radially and vertically). The evaluation of the measured data has been performed by the variance-to-mean ratio (VTMR, Feynman-α), the autocorrelation (ACF, Rossi-α) and the cross-correlation (CCF) methods. The values obtained for the prompt decay constant show a strong bias, which depends both on the detector position and on the source distribution. This is due to the presence of higher modes in the system. It has been observed that the α value fitted is higher when the detector is close to the boundary of the core or to the 252 Cf point-source. The higher alpha-modes have also been observed by fitting functions describing two alpha-modes. The successful set of measurement also provides a good basis for further theoretical investigations including the Monte Carlo simulation of the noise measurements and the calculation of the alpha-modes in the Delphi subcritical assembly. (authors)

  18. Optimal Linear Filters for Pulse Height Measurements in the Presence of Noise

    International Nuclear Information System (INIS)

    Nygaard, K.

    1966-07-01

    For measurements of nuclear pulse height spectra a linear filter is used between the pulse amplifier and the pulse height recorder so as to improve the signal/noise ratio. The problem of finding the optimal filter is investigated with emphasis on technical realizability. The maximum available signal/noise ratio is theoretically calculated on the basis of all the information which can be found in the output of the pulse amplifier, and on an assumed a priori knowledge of the pulse time of arrival. It is then shown that the maximum available signal/noise ratio can be obtained with practical measurements without any a priori knowledge of pulse time of arrival, and a general description of the optimal linear filter is given. The solution is unique, technically realizable, and based solely on data (noise power spectrum and pulse shape) which can be measured at the output terminals of the pulse amplifier used

  19. Optimal Linear Filters for Pulse Height Measurements in the Presence of Noise

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, K

    1966-07-15

    For measurements of nuclear pulse height spectra a linear filter is used between the pulse amplifier and the pulse height recorder so as to improve the signal/noise ratio. The problem of finding the optimal filter is investigated with emphasis on technical realizability. The maximum available signal/noise ratio is theoretically calculated on the basis of all the information which can be found in the output of the pulse amplifier, and on an assumed a priori knowledge of the pulse time of arrival. It is then shown that the maximum available signal/noise ratio can be obtained with practical measurements without any a priori knowledge of pulse time of arrival, and a general description of the optimal linear filter is given. The solution is unique, technically realizable, and based solely on data (noise power spectrum and pulse shape) which can be measured at the output terminals of the pulse amplifier used.

  20. Measurements of 1/f noise in A-Si:H pin diodes and thin-film-transistors

    International Nuclear Information System (INIS)

    Cho, Gyuseong; Drewery, J.S.; Fujieda, I.; Jing, T.; Kaplan, S.N.; Perez-Mendez, V.; Qureshi, S.; Wildermuth, D.; Street, R.A.

    1990-05-01

    We measured the equivalent noise charge of a-Si:H pin diodes (5 ∼ 45μm i-layer) with a pulse shaping time of 2.5 μsec under reverse biases up to 30 V/μm and analyzed it as a four component noise source. The frequency spectra of 1/f noise on the soft-breakdown region and of the Nyquist noise from contact resistance of diodes were measured. Using the conversion equations for a CR-RC shaper, we identified the contact resistance noise and the 1/f noise as the main noise sources in the low bias and high bias regions respectively. The 1/f noise of a-Si:H TFTs with channel length of 15 μm was measured to be the dominant component up to ∼100kHz for both saturation and linear regions. 15 refs., 7 figs

  1. Comparison between the corrosion forecast based on the potential measurement and the determination of the corrosion rate of the reinforcement bar by means of electrochemical techniques

    Directory of Open Access Journals (Sweden)

    Castaneda, A.

    2003-12-01

    Full Text Available The ASTA4 876-91 standard establishes a corrosion forecast of concrete reinforced bar by measuring the electrochemical potential. This forecast is based on thermodynamic considerations without taking into account the kinetic of the corrosion process. A comparison was made between the results obtained based on this standard and others using electrochemical techniques (Tafel, Rp, EIS, Electrochemical Noise. These techniques allows to obtain the corrosion rate in samples having 0.4, 0.5 and 0.66 water/cement ratios submitted to salt spray outdoors and by immersion in 3% saline solution during a test time of 20 months. Differences were detected between the results obtained using the ASTM standard and the electrochemical techniques used. The main difference is that samples submitted to immersion shows a higher probability of corrosion than samples submitted to salt spray; however, the electrochemical techniques showed the contrary concerning the corrosion kinetic process .A comparison respecting corrosion rate was also made between the results obtained by the different electrochemical techniques. It is very well known that all electrochemical techniques supposed always general corrosion except electrochemical noise. Using the technique the pitting index can be calculated. It shows that localized corrosion is the most predominant

    La norma ASTM 876-91 establece un pronóstico de corrosión de la barra de refuerzo del hormigón armado mediante la determinación de potenciales electroquímicos. Este pronóstico se basa en consideraciones termodinámicas, sin tener en cuenta la cinética del proceso de corrosión. Se comparan los resultados obtenidos aplicando esta norma con técnicas electroquímicas (Tafel, Rp, EIS, Ruido Electroquímico que permiten calcular la velocidad de corrosión en probetas con relaciones agua/cemento 0,4, 0,5 y 0,66 sometidas a niebla salina en condiciones naturales y en inmersión en solución salina al 3% durante un

  2. [De-noising and measurement of pulse wave velocity of the wavelet].

    Science.gov (United States)

    Liu, Baohua; Zhu, Honglian; Ren, Xiaohua

    2011-02-01

    Pulse wave velocity (PWV) is a vital index of the cardiovascular pathology, so that the accurate measurement of PWV can be of benefit for prevention and treatment of cardiovascular diseases. The noise in the measure system of pulse wave signal, rounding error and selection of the recording site all cause errors in the measure result. In this paper, with wavelet transformation to eliminate the noise and to raise the precision, and with the choice of the point whose slope was maximum as the recording site of the reconstructing pulse wave, the measuring system accuracy was improved.

  3. MICROWAVE NOISE MEASUREMENT OF ELECTRON TEMPERATURES IN AFTERGLOW PLASMAS

    Energy Technology Data Exchange (ETDEWEB)

    Leiby, Jr., C. C.; McBee, W. D.

    1963-10-15

    Transient electron temperatures in afterglow plasmas were determined for He (5 and 10 torr), Ne, and Ne plus or minus 5% Ar (2.4 and 24 torr) by combining measurements of plasma microwave noise power, and plasma reflectivity and absorptivity. Use of a low-noise parametric preamplifier permitted continuous detection during the afterglow of noise power at 5.5 Bc in a 1 Mc bandwidth. Electron temperature decays were a function of pressure and gas but were slower than predicted by electron energy loss mechanisms. The addition of argon altered the electron density decay in the neon afterglow but the electron temperature decay was not appreciably changed. Resonances in detected noise power vs time in the afterglow were observed for two of the three plasma waveguide geometries studied. These resonances correlate with observed resonances in absorptivity and occur over the same range of electron densities for a given geometry independent of gas type and pressure. (auth)

  4. Assessing the effects of noise abatement measures on health risks: A case study in Istanbul

    International Nuclear Information System (INIS)

    Ongel, Aybike; Sezgin, Fatih

    2016-01-01

    In recent decades, noise pollution caused by industrialization and increased motorization has become a major concern around the world because of its adverse effects on human well-being. Therefore, transportation agencies have been implementing noise abatement measures in order to reduce road traffic noise. However, limited attention is given to noise in environmental assessment of road transportation systems. This paper presents a framework for a health impact assessment model for road transportation noise emissions. The model allows noise impacts to be addressed with the health effects of air pollutant and greenhouse gas emissions from road transportation. The health damages assessed in the model include annoyance, sleep disturbance, and cardiovascular disease in terms of acute myocardial infarction. The model was applied in a case study in Istanbul in order to evaluate the change in health risks from the implementation of noise abatement strategies. The noise abatement strategies evaluated include altering pavement surfaces in order to absorb noise and introducing speed limits. It was shown that significant improvements in health risks can be achieved using open graded pavement surfaces and introducing speed limits on highways. - Highlights: • Transportation noise has a significant effect on health. • Noise should be included in the environmental assessment of transportation systems. • Traffic noise abatement measures include noise reducing pavements and speed limits. • Noise abatement measures help reduce the health risks of transportation noise. • Speed limit reduction on uncongested roads is an effective way to reduce health risks.

  5. Assessing the effects of noise abatement measures on health risks: A case study in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Ongel, Aybike, E-mail: aybike.ongel@eng.bahcesehir.edu.tr [Bahcesehir University, Department of Civil Engineering, Istanbul 34353 (Turkey); Sezgin, Fatih, E-mail: fatih.sezgin@ibb.gov.tr [Istanbul Metropolitan Municipality, Environmental Protection Agency, Istanbul 34169 (Turkey)

    2016-01-15

    In recent decades, noise pollution caused by industrialization and increased motorization has become a major concern around the world because of its adverse effects on human well-being. Therefore, transportation agencies have been implementing noise abatement measures in order to reduce road traffic noise. However, limited attention is given to noise in environmental assessment of road transportation systems. This paper presents a framework for a health impact assessment model for road transportation noise emissions. The model allows noise impacts to be addressed with the health effects of air pollutant and greenhouse gas emissions from road transportation. The health damages assessed in the model include annoyance, sleep disturbance, and cardiovascular disease in terms of acute myocardial infarction. The model was applied in a case study in Istanbul in order to evaluate the change in health risks from the implementation of noise abatement strategies. The noise abatement strategies evaluated include altering pavement surfaces in order to absorb noise and introducing speed limits. It was shown that significant improvements in health risks can be achieved using open graded pavement surfaces and introducing speed limits on highways. - Highlights: • Transportation noise has a significant effect on health. • Noise should be included in the environmental assessment of transportation systems. • Traffic noise abatement measures include noise reducing pavements and speed limits. • Noise abatement measures help reduce the health risks of transportation noise. • Speed limit reduction on uncongested roads is an effective way to reduce health risks.

  6. Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

    International Nuclear Information System (INIS)

    Greenen, Adam; Pearce, Jonathan; Cruickshank, David; Bramley, Paul

    2015-01-01

    The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

  7. Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

    Energy Technology Data Exchange (ETDEWEB)

    Greenen, Adam; Pearce, Jonathan [National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, (United Kingdom); Cruickshank, David; Bramley, Paul [Metrosol Limited, Plum Park Estate, Watling Street, Paulerspury, Northamptonshire, NN12 6LQ, (United Kingdom)

    2015-07-01

    The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

  8. Speech-in-Noise Tests and Supra-threshold Auditory Evoked Potentials as Metrics for Noise Damage and Clinical Trial Outcome Measures.

    Science.gov (United States)

    Le Prell, Colleen G; Brungart, Douglas S

    2016-09-01

    In humans, the accepted clinical standards for detecting hearing loss are the behavioral audiogram, based on the absolute detection threshold of pure-tones, and the threshold auditory brainstem response (ABR). The audiogram and the threshold ABR are reliable and sensitive measures of hearing thresholds in human listeners. However, recent results from noise-exposed animals demonstrate that noise exposure can cause substantial neurodegeneration in the peripheral auditory system without degrading pure-tone audiometric thresholds. It has been suggested that clinical measures of auditory performance conducted with stimuli presented above the detection threshold may be more sensitive than the behavioral audiogram in detecting early-stage noise-induced hearing loss in listeners with audiometric thresholds within normal limits. Supra-threshold speech-in-noise testing and supra-threshold ABR responses are reviewed here, given that they may be useful supplements to the behavioral audiogram for assessment of possible neurodegeneration in noise-exposed listeners. Supra-threshold tests may be useful for assessing the effects of noise on the human inner ear, and the effectiveness of interventions designed to prevent noise trauma. The current state of the science does not necessarily allow us to define a single set of best practice protocols. Nonetheless, we encourage investigators to incorporate these metrics into test batteries when feasible, with an effort to standardize procedures to the greatest extent possible as new reports emerge.

  9. Measurement, characterization, and modeling of noise in staring infrared focal plane arrays

    International Nuclear Information System (INIS)

    Scribner, D.A.; Kruer, M.R.; Gridley, C.J.; Sarkady, K.

    1987-01-01

    An account is given of selected methods for the measurement and characterization of spatial and temporal noise in staring focal plane arrays (FPAs), in order to demonstrate how these results can be used in simulations and analytic models to predict the performance of selected staring sensors. Attention is given to MIR FPAs applicable to the detection and tracking of point sources, and to the ways in which these spatial and temporal noise measurements can be incorporated into simulations and sensors having staring FPAs. Methods for predicting the performance of selected staring sensor systems are derivable from spatial and temporal noise values. 13 references

  10. Source modelling of train noise - Literature review and some initial measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xuetao; Jonasson, Hans; Holmberg, Kjell

    2000-07-01

    A literature review of source modelling of railway noise is reported. Measurements on a special test rig at Surahammar and on the new railway line between Arlanda and Stockholm City are reported and analyzed. In the analysis the train is modelled as a number of point sources with or without directivity and each source is combined with analytical sound propagation theory to predict the sound propagation pattern best fitting the measured data. Wheel/rail rolling noise is considered to be the most important noise source. The rolling noise can be modelled as an array of moving point sources, which have a dipole-like horizontal directivity and some kind of vertical directivity. In general it is necessary to distribute the point sources on several heights. Based on our model analysis the source heights for the rolling noise should be below the wheel axles and the most important height is about a quarter of wheel diameter above the railheads. When train speeds are greater than 250 km/h aerodynamic noise will become important and even dominant. It may be important for low frequency components only if the train speed is less than 220 km/h. Little data are available for these cases. It is believed that aerodynamic noise has dipole-like directivity. Its spectrum depends on many factors: speed, railway system, type of train, bogies, wheels, pantograph, presence of barriers and even weather conditions. Other sources such as fans, engine, transmission and carriage bodies are at most second order noise sources, but for trains with a diesel locomotive engine the engine noise will be dominant if train speeds are less than about 100 km/h. The Nord 2000 comprehensive model for sound propagation outdoors, together with the source model that is based on the understandings above, can suitably handle the problems of railway noise propagation in one-third octave bands although there are still problems left to be solved.

  11. NACA0015 measurements in LM wind tunnel and turbulence generated noise

    Energy Technology Data Exchange (ETDEWEB)

    Bertagnolio, Franck

    2008-11-15

    A NACA0015 airfoil section was instrumented with an array of highfrequency microphones mounted on its surface and measured in the wind tunnel at LM Glasfiber at various inflow speeds, angles of attack, and with different turbulent inflow conditions. The aim of this work is to analyze these measurement data, including the turbulent inflow characteristics. The airfoil surface pressure data are considered in the perspective of turbulent inflow noise in order to identify the potential for using these data to validate and possibly improve associated noise models from the literature. In addition, these data are further analyzed in the context of trailing edge noise modeling which is directly related to the surface pressure fluctuations in the vicinity of the trailing edge. (au)

  12. Measurement of spectral phase noise in a cryogenically cooled Ti:Sa amplifier (Conference Presentation)

    Science.gov (United States)

    Nagymihaly, Roland S.; Jójárt, Péter; Börzsönyi, Ádám.; Osvay, Károly

    2017-05-01

    In most of cases the drift of the carrier envelope phase (CEP) of a chirped pulse amplifier (CPA) system is determined only [1], being the relevant parameter at laser-matter interactions. The need of coherent combination of multiple amplifier channels to further increase the peak power of pulses requires interferometric precision [2]. For this purpose, the stability of the group delay of the pulses may become equally important. Further development of amplifier systems requires the investigation of phase noise contributions of individual subsystems, like amplifier stages. Spectrally resolved interferometry (SRI), which is a completely linear optical method, makes the measurement of spectral phase noise possible of basically any part of a laser system [3]. By utilizing this method, the CEP stability of water-cooled Ti:Sa based amplifiers was investigated just recently, where the effects of seed and pump energy, repetition rate, and the cooling crystal mounts were thoroughly measured [4]. We present a systematic investigation on the noise of the spectral phase, including CEP, of laser pulses amplified in a cryogenically-cooled Ti:Sa amplifier of a CPA chain. The double-pass amplifier was built in the sample arm of a compact Michelson interferometer. The Ti:Sa crystal was cooled below 30 °K. The inherent phase noise was measured for different operation modes, as at various repetition rates, and pump depletion. Noise contributions of the vacuum pumps and the cryogenic refrigerator were found to be 43 and 47 mrad, respectively. We have also identified CEP noise having thermal as well as mechanical origin. Both showed a monotonically decreasing tendency towards higher repetition rates. We found that the widths of the noise distributions are getting broader towards lower repetition rates. Spectral phase noise with and without amplification was measured, and we found no significant difference in the phase noise distributions. The mechanical vibration was also measured in

  13. Luminance noise as a novel approach for measuring contrast sensitivity within the magnocellular and parvocellular pathways.

    Science.gov (United States)

    Hall, Cierra M; McAnany, J Jason

    2017-07-01

    This study evaluated the extent to which different types of luminance noise can be used to target selectively the inferred magnocellular (MC) and parvocellular (PC) visual pathways. Letter contrast sensitivity (CS) was measured for three visually normal subjects for letters of different size (0.8°-5.3°) under established paradigms intended to target the MC pathway (steady-pedestal paradigm) and PC pathway (pulsed-pedestal paradigm). Results obtained under these paradigms were compared to those obtained in asynchronous static noise (a field of unchanging luminance noise) and asynchronous dynamic noise (a field of randomly changing luminance noise). CS was measured for letters that were high- and low-pass filtered using a range of filter cutoffs to quantify the object frequency information (cycles per letter) mediating letter identification, which was used as an index of the pathway mediating CS. A follow-up experiment was performed to determine the range of letter duration over which MC and PC pathway CS can be targeted. Analysis of variance indicated that the object frequencies measured under the static noise and steady-pedestal paradigms did not differ significantly (p ≥ 0.065), but differed considerably from those measured under the dynamic noise (both p noise, and in dynamic noise. These data suggest that the spatiotemporal characteristics of noise can be manipulated to target the inferred MC (static noise) and PC (dynamic noise) pathways. The results also suggest that CS within these pathways can be measured at long stimulus durations, which has potential importance in the design of future clinical CS tests.

  14. Radio-frequency shot-noise measurement in a magnetic tunnel junction with a MgO barrier

    International Nuclear Information System (INIS)

    Rehman, Mushtaq; Park, Junghwan; Song, Woon; Chong, Yonuk; Lee, Yeonsub; Min, Byoungchul; Shin, Kyungho; Ryu, Sangwan; Khim, Zheong

    2010-01-01

    We measured the noise power of a magnetic tunnel junction in the frequency range of 710 ∼ 1200 MHz. A low-noise cryogenic HEMT amplifier was used to measure the small noise signal at a high frequency with wide bandwidth. The MgO-barrier tunnel junction showed large tunnel magnetoresistance ratio of 215% at low temperature, which indicates electronic transport through the tunnel barrier without any significant spin-flip scattering. In the bias-dependent noise measurement, however, the zero-bias shot noise was enhanced compared to the value expected from a perfect tunnel barrier or the value observed from a good Al-AlO x -Al tunnel junction. We assume that this enhanced noise comes from inelastic tunneling processes through the barrier, which may be related to the observed zero-bias anomaly in the differential resistance of the tunnel junctions. We present a simple phenomenological model for how the inelastic scattering process can enhance the zero-bias noise in a tunnel junction.

  15. Air flow measurement techniques applied to noise reduction of a centrifugal blower

    Science.gov (United States)

    Laage, John W.; Armstrong, Ashli J.; Eilers, Daniel J.; Olsen, Michael G.; Mann, J. Adin

    2005-09-01

    The air flow in a centrifugal blower was studied using a variety of flow and sound measurement techniques. The flow measurement techniques employed included Particle Image Velocimetry (PIV), pitot tubes, and a five hole spherical probe. PIV was used to measure instantaneous and ensemble-averaged velocity fields over large area of the outlet duct as a function of fan position, allowing for the visualization of the flow as it leave the fan blades and progressed downstream. The results from the flow measurements were reviewed along side the results of the sound measurements with the goal of identifying sources of noise and inefficiencies in flow performance. The radiated sound power was divided into broadband and tone noise and measures of the flow. The changes in the tone and broadband sound were compared to changes in flow quantities such as the turbulent kinetic energy and Reynolds stress. Results for each method will be presented to demonstrate the strengths of each flow measurement technique as well as their limitations. Finally, the role that each played in identifying noise sources is described.

  16. Field-Deployable Acoustic Digital Systems for Noise Measurement

    Science.gov (United States)

    Shams, Qamar A.; Wright, Kenneth D.; Lunsford, Charles B.; Smith, Charlie D.

    2000-01-01

    Langley Research Center (LaRC) has for years been a leader in field acoustic array measurement technique. Two field-deployable digital measurement systems have been developed to support acoustic research programs at LaRC. For several years, LaRC has used the Digital Acoustic Measurement System (DAMS) for measuring the acoustic noise levels from rotorcraft and tiltrotor aircraft. Recently, a second system called Remote Acquisition and Storage System (RASS) was developed and deployed for the first time in the field along with DAMS system for the Community Noise Flight Test using the NASA LaRC-757 aircraft during April, 2000. The test was performed at Airborne Airport in Wilmington, OH to validate predicted noise reduction benefits from alternative operational procedures. The test matrix was composed of various combinations of altitude, cutback power, and aircraft weight. The DAMS digitizes the acoustic inputs at the microphone site and can be located up to 2000 feet from the van which houses the acquisition, storage and analysis equipment. Digitized data from up to 10 microphones is recorded on a Jaz disk and is analyzed post-test by microcomputer system. The RASS digitizes and stores acoustic inputs at the microphone site that can be located up to three miles from the base station and can compose a 3 mile by 3 mile array of microphones. 16-bit digitized data from the microphones is stored on removable Jaz disk and is transferred through a high speed array to a very large high speed permanent storage device. Up to 30 microphones can be utilized in the array. System control and monitoring is accomplished via Radio Frequency (RF) link. This paper will present a detailed description of both systems, along with acoustic data analysis from both systems.

  17. Reliable clinical serum analysis with reusable electrochemical sensor: Toward point-of-care measurement of the antipsychotic medication clozapine.

    Science.gov (United States)

    Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F

    2017-09-15

    Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Intrinsic periodic and aperiodic stochastic resonance in an electrochemical cell

    Science.gov (United States)

    Tiwari, Ishant; Phogat, Richa; Parmananda, P.; Ocampo-Espindola, J. L.; Rivera, M.

    2016-08-01

    In this paper we show the interaction of a composite of a periodic or aperiodic signal and intrinsic electrochemical noise with the nonlinear dynamics of an electrochemical cell configured to study the corrosion of iron in an acidic media. The anodic voltage setpoint (V0) in the cell is chosen such that the anodic current (I ) exhibits excitable fixed point behavior in the absence of noise. The subthreshold periodic (aperiodic) signal consists of a train of rectangular pulses with a fixed amplitude and width, separated by regular (irregular) time intervals. The irregular time intervals chosen are of deterministic and stochastic origins. The amplitude of the intrinsic internal noise, regulated by the concentration of chloride ions, is then monotonically increased, and the provoked dynamics are analyzed. The signal to noise ratio and the cross-correlation coefficient versus the chloride ions' concentration curves have a unimodal shape indicating the emergence of an intrinsic periodic or aperiodic stochastic resonance. The abscissa for the maxima of these unimodal curves correspond to the optimum value of intrinsic noise where maximum regularity of the invoked dynamics is observed. In the particular case of the intrinsic periodic stochastic resonance, the scanning electron microscope images for the electrode metal surfaces are shown for certain values of chloride ions' concentrations. These images, qualitatively, corroborate the emergence of order as a result of the interaction between the nonlinear dynamics and the composite signal.

  19. Electrochemical vs X-ray Spectroscopic Measurements of NiFe(CN)6 Crystals

    Science.gov (United States)

    Peecher, Benjamin; Hampton, Jennifer

    Pseudocapacitive materials like hexacyanoferrate have greater energy storage capabilities than standard capacitors while maintaining an ability to charge and discharge quickly. We modify the surface of an electrodeposited Ni thin film with a layer of hexacyanoferrate. Charging and discharging these modified films using cyclic voltammetry (CV) allows us to measure the electrochemically active Fe in the film. To determine how closely this resembles the full amount of Fe in the film, we measure the films' composition using particle-induced x-ray emission (PIXE). We also vary the amount of Ni deposited, both to compare the electrolysis value of charge deposited to the PIXE measurement of Ni in the film, and also to measure how varying the thickness of the Ni surface affects the presence of Fe in the film. Comparisons of the CV and PIXE measurements show agreement in Ni levels but disagreement in Fe levels. PIXE measurements of Fe in the film have positive correlation with Ni in the film. This correlation between PIXE measurements of Ni and Fe suggests that PIXE provides a reliable measure of Fe in the film. This implies that a variable proportion of total Fe in a given film is electrochemically active. This research was made possible by the Hope College Department of Physics Frissel Research Fund and the National Science Foundation under Grants RUI-DMR-1104725, MRI-CHE-0959282, and MRI/RUI-PHY-0319523.

  20. An Analysis of FM Jamming and Noise Quality Measures

    Science.gov (United States)

    1993-12-01

    equipment setup is shown in figure 6. For reasons of practicality and manageability , all equipment was chosen to be commercially available and of a fairly...bins based on the size of the parameter F. It computes a smoothed "Turner Noise Qaulity " similar to the noise quality measure employed by Daly in his...recý.orate for :nf-,aton Doe,A-,ým5 1o- A c-t•s. )2 15 efferso Oarts H,9gPay, Srte 1204. ArtOngton, VA 222024302 and to the Of"ce of Management and aucige

  1. First evaluation of low frequency noise measurements of in core detector signals in the measuring assembly Rheinsberg

    International Nuclear Information System (INIS)

    Collatz, S.

    1982-01-01

    Reactor noise spectra of in core neutron detectors are measured in the low frequency range (0.03 Hz to 1 Hz) and evaluated. The increase of the effective noise signal value is due to pressure oscillations or oscillations of special steam volume portions. Thus boiling monitoring of reactor cores in PWR type reactors may be possible, if the low frequency noise of the whole set of in core detectors is taken into account

  2. Inference from the futures: ranking the noise cancelling accuracy of realized measures

    DEFF Research Database (Denmark)

    Mirone, Giorgio

    We consider the log-linear relationship between futures contracts and their underlying assets and show that in the classical Brownian semi-martingale (BSM) framework the two series must, by no-arbitrage, have the same integrated variance. We then introduce the concept of noise cancelling...... measures in the presence of noise. Moreover, a thorough simulation analysis is employed to evaluate the estimators' sensitivity to different price and noise processes, and sampling frequencies....

  3. Towards measuring the off-resonant thermal noise of a pendulum mirror

    CERN Document Server

    Leonhardt, V; Kloevekorn, P; Willke, B; Lück, H B; Danzmann, K

    2002-01-01

    Thermal noise is one of the dominant noise sources in interferometric length measurements and can limit the sensitivity of gravitational wave detectors. Our goal is to analyse the off-resonant thermal noise of a high Q pendulum. Therefore we interferometrically detect the length changes of a 2.3 cm long optical resonator, which for good seismic isolation consists of two multiple stage pendulums. We are able to lock the length of this optical resonator to a frequency-stabilized laser beam and as a result get the spectral density of the differential mirror movement.

  4. A combined aeroelastic-aeroacoustic model for wind turbine noise: Verification and analysis of field measurements

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Fischer, Andreas

    2017-01-01

    In this paper, semi-empirical engineering models for the three main wind turbine aerodynamic noise sources, namely, turbulent inflow, trailing edge and stall noise, are introduced. They are implemented into the in-house aeroelastic code HAWC2 commonly used for wind turbine load calculations...... and design. The results of the combined aeroelastic and aeroacoustic model are compared with field noise measurements of a 500kW wind turbine. Model and experimental data are in fairly good agreement in terms of noise levels and directivity. The combined model allows separating the various noise sources...... and highlights a number of mechanisms that are difficult to differentiate when only the overall noise from a wind turbine is measured....

  5. A Compact Microelectrode Array Chip with Multiple Measuring Sites for Electrochemical Applications

    Directory of Open Access Journals (Sweden)

    Maria Dimaki

    2014-05-01

    Full Text Available In this paper we demonstrate the fabrication and electrochemical characterization of a microchip with 12 identical but individually addressable electrochemical measuring sites, each consisting of a set of interdigitated electrodes acting as a working electrode as well as two circular electrodes functioning as a counter and reference electrode in close proximity. The electrodes are made of gold on a silicon oxide substrate and are passivated by a silicon nitride membrane. A method for avoiding the creation of high edges at the electrodes (known as lift-off ears is presented. The microchip design is highly symmetric to accommodate easy electronic integration and provides space for microfluidic inlets and outlets for integrated custom-made microfluidic systems on top.

  6. A novel approach to reduce environmental noise in microgravity measurements using a Scintrex CG5

    Science.gov (United States)

    Boddice, Daniel; Atkins, Phillip; Rodgers, Anthony; Metje, Nicole; Goncharenko, Yuriy; Chapman, David

    2018-05-01

    The accuracy and repeatability of microgravity measurements for surveying purposes are affected by two main sources of noise; instrument noise from the sensor and electronics, and environmental sources of noise from anthropogenic activity, wind, microseismic activity and other sources of vibrational noise. There is little information in the literature on the quantitative values of these different noise sources and their significance for microgravity measurements. Experiments were conducted to quantify these sources of noise with multiple instruments, and to develop methodologies to reduce these unwanted signals thereby improving the accuracy or speed of microgravity measurements. External environmental sources of noise were found to be concentrated at higher frequencies (> 0.1 Hz), well within the instrument's bandwidth. In contrast, the internal instrumental noise was dominant at frequencies much lower than the reciprocal of the maximum integration time, and was identified as the limiting factor for current instruments. The optimum time for integration was found to be between 120 and 150 s for the instruments tested. In order to reduce the effects of external environmental noise on microgravity measurements, a filtering and despiking technique was created using data from noisy environments next to a main road and outside on a windy day. The technique showed a significant improvement in the repeatability of measurements, with between 40% and 50% lower standard deviations being obtained over numerous different data sets. The filtering technique was then tested in field conditions by using an anomaly of known size, and a comparison made between different filtering methods. Results showed improvements with the proposed method performing better than a conventional, or boxcar, averaging process. The proposed despiking process was generally found to be ineffective, with greater gains obtained when complete measurement records were discarded. Field survey results were

  7. Measurements of noise immission from wind turbines at receptor locations: Use of a vertical microphone board to improve the signal-to-noise ratio

    International Nuclear Information System (INIS)

    Fegeant, Olivier

    1999-01-01

    The growing interest in wind energy has increased the need of accuracy in wind turbine noise immission measurements and thus, the need of new measurement techniques. This paper shows that mounting the microphone on a vertical board improves the signal-to-noise ratio over the whole frequency range compared to the free microphone technique. Indeed, the wind turbine is perceived two times noisier by the microphone due to the signal reflection by the board while, in addition, the wind noise is reduced. Furthermore, the board shielding effect allows the measurements to be carried out in the presence of reflecting surfaces such as building facades

  8. An instantaneous spatiotemporal model to predict a bicyclist's Black Carbon exposure based on mobile noise measurements

    Science.gov (United States)

    Dekoninck, Luc; Botteldooren, Dick; Int Panis, Luc

    2013-11-01

    Several studies have shown that a significant amount of daily air pollution exposure, in particular Black Carbon (BC), is inhaled during trips. Assessing this contribution to exposure remains difficult because on the one hand local air pollution maps lack spatio-temporal resolution, at the other hand direct measurement of particulate matter concentration remains expensive. This paper proposes to use in-traffic noise measurements in combination with geographical and meteorological information for predicting BC exposure during commuting trips. Mobile noise measurements are cheaper and easier to perform than mobile air pollution measurements and can easily be used in participatory sensing campaigns. The uniqueness of the proposed model lies in the choice of noise indicators that goes beyond the traditional overall A-weighted noise level used in previous work. Noise and BC exposures are both related to the traffic intensity but also to traffic speed and traffic dynamics. Inspired by theoretical knowledge on the emission of noise and BC, the low frequency engine related noise and the difference between high frequency and low frequency noise that indicates the traffic speed, are introduced in the model. In addition, it is shown that splitting BC in a local and a background component significantly improves the model. The coefficients of the proposed model are extracted from 200 commuter bicycle trips. The predicted average exposure over a single trip correlates with measurements with a Pearson coefficient of 0.78 using only four parameters: the low frequency noise level, wind speed, the difference between high and low frequency noise and a street canyon index expressing local air pollution dispersion properties.

  9. The effect of noise in a performance measure on work motivation: A real effort laboratory experiment

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2008-01-01

    This paper reports the results of an individual real effort laboratory experiment where subjects are paid for measured performance. Measured performance equals actual performance plus noise. We compare a stable environment where the noise is small with a volatile environment where the noise is

  10. The effect of noise in a performance measure on work motivation: A real effort laboratory experiment

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2010-01-01

    This paper reports the results of an individual real effort laboratory experiment where subjects are paid for measured performance. Measured performance equals actual performance plus noise. We compare a stable environment where the noise is small with a volatile environment where the noise is

  11. Noise analysis of the measurement of group delay in Fourier white-light interferometric cross correlation

    International Nuclear Information System (INIS)

    Laude, Vincent

    2002-01-01

    The problem of noise analysis in measuring the group delay introduced by a dispersive optical element by use of white-light interferometric cross correlation is investigated. Two noise types, detection noise and position noise, are specifically analyzed. Detection noise is shown to be highly sensitive to the spectral content of the white-light source at the frequency considered and to the temporal acquisition window. Position noise, which arises from the finite accuracy of the measurement of the scanning mirror's position, can severely damage the estimation of the group delay. Such is shown to be the case for fast Fourier transform-based estimation algorithms. A new algorithm that is insensitive to scanning delay errors is proposed, and subfemtosecond accuracy is obtained without any postprocessing

  12. Practical ranges of loudness levels of various types of environmental noise, including traffic noise, aircraft noise, and industrial noise

    NARCIS (Netherlands)

    Salomons, E.M.; Janssen, S.A.

    2011-01-01

    In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a

  13. Measurement of signal-to-noise ratio performance of TV fluoroscopy systems

    International Nuclear Information System (INIS)

    Geluk, R.J.

    1985-01-01

    A method has been developed for direct measurement of Signal-to-Noise ratio performance on X-ray TV systems. To this end the TV signal resulting from a calibrated test object, is compared with the noise level in the image. The method is objective and produces instantaneous readout, which makes it very suitable for system evaluation under dynamic conditions. (author)

  14. Optimal configuration of partial Mueller matrix polarimeter for measuring the ellipsometric parameters in the presence of Poisson shot noise and Gaussian noise

    Science.gov (United States)

    Quan, Naicheng; Zhang, Chunmin; Mu, Tingkui

    2018-05-01

    We address the optimal configuration of a partial Mueller matrix polarimeter used to determine the ellipsometric parameters in the presence of additive Gaussian noise and signal-dependent shot noise. The numerical results show that, for the PSG/PSA consisting of a variable retarder and a fixed polarizer, the detection process immune to these two types of noise can be optimally composed by 121.2° retardation with a pair of azimuths ±71.34° and a 144.48° retardation with a pair of azimuths ±31.56° for four Mueller matrix elements measurement. Compared with the existing configurations, the configuration presented in this paper can effectively decrease the measurement variance and thus statistically improve the measurement precision of the ellipsometric parameters.

  15. Detecting the presence of a magnetic field under Gaussian and non-Gaussian noise by adaptive measurement

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuan-Mei; Li, Jun-Gang, E-mail: jungl@bit.edu.cn; Zou, Jian

    2017-06-15

    Highlights: • Adaptive measurement strategy is used to detect the presence of a magnetic field. • Gaussian Ornstein–Uhlenbeck noise and non-Gaussian noise have been considered. • Weaker magnetic fields may be more easily detected than some stronger ones. - Abstract: By using the adaptive measurement method we study how to detect whether a weak magnetic field is actually present or not under Gaussian noise and non-Gaussian noise. We find that the adaptive measurement method can effectively improve the detection accuracy. For the case of Gaussian noise, we find the stronger the magnetic field strength, the easier for us to detect the magnetic field. Counterintuitively, for non-Gaussian noise, some weaker magnetic fields are more likely to be detected rather than some stronger ones. Finally, we give a reasonable physical interpretation.

  16. Effect of Wind Farm Noise on Local Residents' Decision to Adopt Mitigation Measures.

    Science.gov (United States)

    Botelho, Anabela; Arezes, Pedro; Bernardo, Carlos; Dias, Hernâni; Pinto, Lígia M Costa

    2017-07-11

    Wind turbines' noise is frequently pointed out as the reason for local communities' objection to the installation of wind farms. The literature suggests that local residents feel annoyed by such noise and that, in many instances, this is significant enough to make them adopt noise-abatement interventions on their homes. Aiming at characterizing the relationship between wind turbine noise, annoyance, and mitigating actions, we propose a novel conceptual framework. The proposed framework posits that actual sound pressure levels of wind turbines determine individual homes' noise-abatement decisions; in addition, the framework analyzes the role that self-reported annoyance, and perception of noise levels, plays on the relationship between actual noise pressure levels and those decisions. The application of this framework to a particular case study shows that noise perception and annoyance constitutes a link between the two. Importantly, however, noise also directly affects people's decision to adopt mitigating measures, independently of the reported annoyance.

  17. Effect of Wind Farm Noise on Local Residents’ Decision to Adopt Mitigation Measures

    Science.gov (United States)

    Botelho, Anabela; Bernardo, Carlos; Dias, Hernâni; Pinto, Lígia M. Costa

    2017-01-01

    Wind turbines’ noise is frequently pointed out as the reason for local communities’ objection to the installation of wind farms. The literature suggests that local residents feel annoyed by such noise and that, in many instances, this is significant enough to make them adopt noise-abatement interventions on their homes. Aiming at characterizing the relationship between wind turbine noise, annoyance, and mitigating actions, we propose a novel conceptual framework. The proposed framework posits that actual sound pressure levels of wind turbines determine individual homes’ noise-abatement decisions; in addition, the framework analyzes the role that self-reported annoyance, and perception of noise levels, plays on the relationship between actual noise pressure levels and those decisions. The application of this framework to a particular case study shows that noise perception and annoyance constitutes a link between the two. Importantly, however, noise also directly affects people’s decision to adopt mitigating measures, independently of the reported annoyance. PMID:28696404

  18. Electrostatic noise measurement with a pair of spherical probes near interplanetary shocks

    International Nuclear Information System (INIS)

    Solomon, J.; Touzin, F.

    1991-01-01

    In order to obtain accurate measurements of electrostatic noise spectra on board the ISEE 1 satellite, near interplanetary shock waves, the authors perform a detailed theoretical and numerical study of an antenna consisting of a pair of spherical probes. They compute the quasi-thermal electrostatic noise observed theoretically on the antenna by assuming that the solar wind plasma can be properly represented by the sum of two Maxwellian distributions (core and halo). They study the dependence of the electrostatic spectra on the antenna length and on the different plasma parameters, particularly on the density and temperature ratio of the core and of the halo. They show that by also taking into account the instrumental noise and the shot noise on the antenna, a calibration factor can be precisely determined for the antenna that they consider. They display some results obtained from measurements of electrostatic noise spectra behind interplanetary shock waves. Finally, they discuss the real meaning of a specific halo temperature, and they show that, in a first approximation, the theoretical results are only slightly modified when they consider types of distributions other than Maxwellians

  19. CHROMATE INHIBITION OF THE LOCALIZED CORROSION OF ALUMINUM: MEASUREMENTS OF ELECTROCHEMICAL TRANSIENTS

    International Nuclear Information System (INIS)

    SASAKI, K.; ISAACS, H.S.

    2001-01-01

    We investigated the inhibition by chromate ions of the localized corrosion of aluminum by electrochemical transient measurements. In agreement with other work, the measurements demonstrated that chromate is a cathodic inhibitor for aluminum in open circuit. The reduction of hexavalent chromium to trivalent chromium is assumed to take place on catalyzed sites of the surface. The resulting products inhibit oxygen reduction reactions at these sites, thereby retarding pitting corrosion

  20. Instrumentation for Gate Current Noise Measurements on sub-100 nm MOS Transistors

    CERN Document Server

    Gaioni, L; Ratti, L; Re, V; Speziali, V; Traversi, G

    2008-01-01

    This work describes a measuring system that was developed to characterize the gate current noise performances of CMOS devices with minimum feature size in the 100 nm span. These devices play an essential role in the design of present daymixedsignal integrated circuits, because of the advantages associated with the scaling process. The reduction in the gate oxide thickness brought about by CMOS technology downscaling leads to a non-negligible gate current due to direct tunneling phenomena; this current represents a noise source which requires an accurate characterization for optimum analog design. In this paper, two instruments able to perform measurements in two different ranges of gate current values will be discussed. Some of the results of gate current noise characterization will also be presented.

  1. A generalized formulation for noise-based seismic velocity change measurements

    Science.gov (United States)

    Gómez-García, C.; Brenguier, F.; Boué, P.; Shapiro, N.; Droznin, D.; Droznina, S.; Senyukov, S.; Gordeev, E.

    2017-12-01

    The observation of continuous seismic velocity changes is a powerful tool for detecting seasonal variations in crustal structure, volcanic unrest, co- and post-seismic evolution of stress in fault areas or the effects of fluid injection. The standard approach for measuring such velocity changes relies on comparison of travel times in the coda of a set of seismic signals, usually noise-based cross-correlations retrieved at different dates, and a reference trace, usually a averaged function over dates. A good stability in both space and time of the noise sources is then the main assumption for reliable measurements. Unfortunately, these conditions are often not fulfilled, as it happens when ambient-noise sources are non-stationary, such as the emissions of low-frequency volcanic tremors.We propose a generalized formulation for retrieving continuous time series of noise-based seismic velocity changes without any arbitrary reference cross-correlation function. We set up a general framework for future applications of this technique performing synthetic tests. In particular, we study the reliability of the retrieved velocity changes in case of seasonal-type trends, transient effects (similar to those produced as a result of an earthquake or a volcanic eruption) and sudden velocity drops and recoveries as the effects of transient local source emissions. Finally, we apply this approach to a real dataset of noise cross-correlations. We choose the Klyuchevskoy volcanic group (Kamchatka) as a case study where the recorded wavefield is hampered by loss of data and dominated by strongly localized volcanic tremor sources. Despite the mentioned wavefield contaminations, we retrieve clear seismic velocity drops associated with the eruptions of the Klyuchevskoy an the Tolbachik volcanoes in 2010 and 2012, respectively.

  2. Electrochemical cell and electrode designs for high-temperature/high-pressure kinetic measurements

    International Nuclear Information System (INIS)

    Nagy, Z.; Yonco, R.M.

    1987-05-01

    Many corrosion processes of interest to the nuclear power industry occur in high-temperature/high-pressure aqueous systems. The investigation of the kinetics of the appropriate electrode reactions is a serious experimental challenge, partially because of the high temperatures and pressures and partially because many of these reactions are very rapid, requiring fast relaxation measurements. An electrochemical measuring system is described which is suitable for measurements of the kinetics of fast electrode reactions at temperatures extending to at least 300 0 C and pressures to at least 10 MPa (100 atmospheres). The system includes solution preparation and handling equipment, the electrochemical cell, and several electrode designs. One of the new designs is a coaxial working electrode-counter electrode assembly; this electrode can be used with very fast-rising pulses, and it provides a well defined, repeatedly-polishable working surface. Low-impedance reference electrodes are also described, based on electrode concepts responding to the pH or the redox potential of the test solution. Additionally, a novel, long-life primary reference electrode design is reported, based on a modification of the external, pressure-balanced Ag/AgCl reference electrode

  3. Electrochemical cell and electrode designs for high-temperature/high-pressure kinetic measurements

    International Nuclear Information System (INIS)

    Nagy, Z.; Yonco, R.M.

    1988-01-01

    Many corrosion processes of interest to the nuclear power industry occur in high-temperature/high-pressure aqueous systems. The investigation of the kinetics of the appropriate electrode reactions is a serious experimental challenge, partially because of the high temperatures and pressures and partially because many of these reactions are very rapid, requiring fast relaxation measurements. An electrochemical measuring system is described which is suitable for measurements of the kinetics of fast electrode reactions at temperatures extending to at least 300 0 C and pressures to at least 10 MPa (100 atmospheres). The system includes solution preparation and handling equipment, the electrochemical cell, and several electrode designs. One of the new designs is a coaxial working electrode-counter electrode assembly; this electrode can be used with very fast-rising pulses, and it provides a well defined, repeatedly-polishable working surface. Low-impedance reference electrodes are also described, based on electrode concepts responding to the pH or the redox potential of the test solution. Additionally, a novel, long-life primary reference electrode design is reported, based on a modification of the external, pressure-balanced Ag/AgCl reference electrode

  4. Using white noise to gate organic transistors for dynamic monitoring of cultured cell layers.

    Science.gov (United States)

    Rivnay, Jonathan; Leleux, Pierre; Hama, Adel; Ramuz, Marc; Huerta, Miriam; Malliaras, George G; Owens, Roisin M

    2015-06-26

    Impedance sensing of biological systems allows for monitoring of cell and tissue properties, including cell-substrate attachment, layer confluence, and the "tightness" of an epithelial tissue. These properties are critical for electrical detection of tissue health and viability in applications such as toxicological screening. Organic transistors based on conducting polymers offer a promising route to efficiently transduce ionic currents to attain high quality impedance spectra, but collection of complete impedance spectra can be time consuming (minutes). By applying uniform white noise at the gate of an organic electrochemical transistor (OECT), and measuring the resulting current noise, we are able to dynamically monitor the impedance and thus integrity of cultured epithelial monolayers. We show that noise sourcing can be used to track rapid monolayer disruption due to compounds which interfere with dynamic polymerization events crucial for maintaining cytoskeletal integrity, and to resolve sub-second alterations to the monolayer integrity.

  5. Residual stress measurements with barkhausen noise in power plant creep failure analysis

    Energy Technology Data Exchange (ETDEWEB)

    Karvonen, I. [CoMoTest Oy, Maentsaelae (Finland)] Suominen, L. [Stresstech Oy, Jyvaeskylae (Finland)

    1998-12-31

    Continuously developing power and process industry needs predictive maintenance inspection methods in order to prevent failures with correctly timed and properly specified measures. Materials` monitoring has traditionally been non-destructive inspection to detect growing cracks or other deficiencies. Recently, after the development of portable stress measurement systems, some advances has been reached. Based on stress anomalies due to creep, fatigue or corrosion, new applications have been found in the use of Barkhausen noise inspection. When the Barkhausen noise findings have been simultaneously confirmed with other stress measuring methods, a wider acceptance of the application of the method can be proposed. (orig.) 7 refs.

  6. Residual stress measurements with barkhausen noise in power plant creep failure analysis

    Energy Technology Data Exchange (ETDEWEB)

    Karvonen, I. [CoMoTest Oy, Maentsaelae (Finland)] Suominen, L. [Stresstech Oy, Jyvaeskylae (Finland)

    1997-12-31

    Continuously developing power and process industry needs predictive maintenance inspection methods in order to prevent failures with correctly timed and properly specified measures. Materials` monitoring has traditionally been non-destructive inspection to detect growing cracks or other deficiencies. Recently, after the development of portable stress measurement systems, some advances has been reached. Based on stress anomalies due to creep, fatigue or corrosion, new applications have been found in the use of Barkhausen noise inspection. When the Barkhausen noise findings have been simultaneously confirmed with other stress measuring methods, a wider acceptance of the application of the method can be proposed. (orig.) 7 refs.

  7. Aerodynamic Measurements of a Gulfstream Aircraft Model With and Without Noise Reduction Concepts

    Science.gov (United States)

    Neuhart, Dan H.; Hannon, Judith A.; Khorrami, Mehdi R.

    2014-01-01

    Steady and unsteady aerodynamic measurements of a high-fidelity, semi-span 18% scale Gulfstream aircraft model are presented. The aerodynamic data were collected concurrently with acoustic measurements as part of a larger aeroacoustic study targeting airframe noise associated with main landing gear/flap components, gear-flap interaction noise, and the viability of related noise mitigation technologies. The aeroacoustic tests were conducted in the NASA Langley Research Center 14- by 22-Foot Subsonic Wind Tunnel with the facility in the acoustically treated open-wall (jet) mode. Most of the measurements were obtained with the model in landing configuration with the flap deflected at 39º and the main landing gear on and off. Data were acquired at Mach numbers of 0.16, 0.20, and 0.24. Global forces (lift and drag) and extensive steady and unsteady surface pressure measurements were obtained. Comparison of the present results with those acquired during a previous test shows a significant reduction in the lift experienced by the model. The underlying cause was traced to the likely presence of a much thicker boundary layer on the tunnel floor, which was acoustically treated for the present test. The steady and unsteady pressure fields on the flap, particularly in the regions of predominant noise sources such as the inboard and outboard tips, remained unaffected. It is shown that the changes in lift and drag coefficients for model configurations fitted with gear/flap noise abatement technologies fall within the repeatability of the baseline configuration. Therefore, the noise abatement technologies evaluated in this experiment have no detrimental impact on the aerodynamic performance of the aircraft model.

  8. Microphone Handling Noise: Measurements of Perceptual Threshold and Effects on Audio Quality.

    Directory of Open Access Journals (Sweden)

    Paul Kendrick

    Full Text Available A psychoacoustic experiment was carried out to test the effects of microphone handling noise on perceived audio quality. Handling noise is a problem affecting both amateurs using their smartphones and cameras, as well as professionals using separate microphones and digital recorders. The noises used for the tests were measured from a variety of devices, including smartphones, laptops and handheld microphones. The signal features that characterise these noises are analysed and presented. The sounds include various types of transient, impact noises created by tapping or knocking devices, as well as more sustained sounds caused by rubbing. During the perceptual tests, listeners auditioned speech podcasts and were asked to rate the degradation of any unwanted sounds they heard. A representative design test methodology was developed that tried to encourage everyday rather than analytical listening. Signal-to-noise ratio (SNR of the handling noise events was shown to be the best predictor of quality degradation. Other factors such as noise type or background noise in the listening environment did not significantly affect quality ratings. Podcast, microphone type and reproduction equipment were found to be significant but only to a small extent. A model allowing the prediction of degradation from the SNR is presented. The SNR threshold at which 50% of subjects noticed handling noise was found to be 4.2 ± 0.6 dBA. The results from this work are important for the understanding of our perception of impact sound and resonant noises in recordings, and will inform the future development of an automated predictor of quality for handling noise.

  9. Comparison of direct measurement methods for headset noise exposure in the workplace

    Directory of Open Access Journals (Sweden)

    Flora G Nassrallah

    2016-01-01

    Full Text Available The measurement of noise exposure from communication headsets poses a methodological challenge. Although several standards describe methods for general noise measurements in occupational settings, these are not directly applicable to noise assessments under communication headsets. For measurements under occluded ears, specialized methods have been specified by the International Standards Organization (ISO 11904 such as the microphone in a real ear and manikin techniques. Simpler methods have also been proposed in some national standards such as the use of general purpose artificial ears and simulators in conjunction with single number corrections to convert measurements to the equivalent diffuse field. However, little is known about the measurement agreement between these various methods and the acoustic manikin technique. Twelve experts positioned circum-aural, supra-aural and insert communication headsets on four different measurement setups (Type 1, Type 2, Type 3.3 artificial ears, and acoustic manikin. Fit-refit measurements of four audio communication signals were taken under quiet laboratory conditions. Data were transformed into equivalent diffuse-field sound levels using third-octave procedures. Results indicate that the Type 1 artificial ear is not suited for the measurement of sound exposure under communication headsets, while Type 2 and Type 3.3 artificial ears are in good agreement with the acoustic manikin technique. Single number corrections were found to introduce a large measurement uncertainty, making the use of the third-octave transformation preferable.

  10. Multi-target electrochemical biosensing enabled by integrated CMOS electronics

    International Nuclear Information System (INIS)

    Rothe, J; Lewandowska, M K; Heer, F; Frey, O; Hierlemann, A

    2011-01-01

    An integrated electrochemical measurement system, based on CMOS technology, is presented, which allows the detection of several analytes in parallel (multi-analyte) and enables simultaneous monitoring at different locations (multi-site). The system comprises a 576-electrode CMOS sensor chip, an FPGA module for chip control and data processing, and the measurement laptop. The advantages of the highly versatile system are demonstrated by two applications. First, a label-free, hybridization-based DNA sensor is enabled by the possibility of large-scale integration in CMOS technology. Second, the detection of the neurotransmitter choline is presented by assembling the chip with biosensor microprobe arrays. The low noise level enables a limit of detection of, e.g., 0.3 µM choline. The fully integrated system is self-contained: it features cleaning, functionalization and measurement functions without the need for additional electrical equipment. With the power supplied by the laptop, the system is very suitable for on-site measurements

  11. An adaptive filtering method based on EMD for X-ray pulsar navigation with uncertain measurement noise

    Directory of Open Access Journals (Sweden)

    Li N.

    2017-01-01

    Full Text Available Affected by the unstable pulse radiation and the pulsar directional errors, the statistical characteristics of the pulsar measurement noise may vary with time slowly and cannot be accurately determined, which cause the filtering accuracy of the extended Kalman filter(EKF in pulsar navigation positioning system decline sharply or even diverge. To solve this problem, an adaptive extended Kalman filtering algorithm based on the empirical mode decomposition(EMD is proposed. In this method, the high frequency noise is separated from measurement information of pulsar by the method of EMD, and the noise variance can be estimated to update the parameters of EKF. The simulation results demonstrate that compared with conventional EKF, the proposed method can adaptively track the change of the measurement noise, and still keeps high estimation accuracy with unknown measurement noise, the positioning accuracy of the pulsar navigation is improved simultaneously.

  12. Noise measurements of YBa2Cu3O7 thin film high-temperature superconductors

    International Nuclear Information System (INIS)

    Hall, J.J.

    1992-01-01

    The characteristics of thin-film YBa2Cu3O7 superconductors were studied from the superconducting region through the transition region and into the normal region. The properties studied included the resistance-temperature, current-voltage, and electrical noise with concentration of measurements in the transition region. The resistance vs. temperature measurements show a zero resistance followed by a small rise in magnitude at the onset of resistance followed by a sharp increase until the resistance tapers off in the fully normal region. The a-axis films had a larger normal resistivity, a lower critical temperature, and a broader transition than the similar c-axis films. The current(I) - voltage(V) measurements were concentrated in the transition region. A power relation between I and V was found to be V varies as I a(T) where a(T) is temperature dependent starting high the onset of vortex formation, approaches 3 at the vortex unbinding temperature, and goes to 1 when fully normal. This behavior was predicted by the Kosterlitz-Thouless theory and was found experimentally in all four films measured. The current-induced electrical noise characteristics were measured for four samples varying in thickness and axis orientation. Each film exhibited a widely varying magnitude of the noise voltage spectral density (S V ) in the transition region with a leveling off when fully normal. The normalized noise (S V /V squared) showed a sharp decrease in magnitude from the onset of measurable noise continually decreasing until flattening out when fully normal. The a-axis films exhibited S V /V squared over 3 order of magnitude larger than the c-axis films in the transition and normal regions. The normalized temperature coefficient of resistance (beta) was plotted against S V /V squared on a log-log scale to see if the noise generated was due to temperature fluctuations (slope = 2)

  13. A facile electrode preparation method for accurate electrochemical measurements of double-side-coated electrode from commercial Li-ion batteries

    Science.gov (United States)

    Zhou, Ge; Wang, Qiyu; Wang, Shuo; Ling, Shigang; Zheng, Jieyun; Yu, Xiqian; Li, Hong

    2018-04-01

    The post mortem electrochemical analysis, including charge-discharge and electrochemical impedance spectroscopy (EIS) measurements, are critical steps for revealing the failure mechanisms of commercial lithium-ion batteries (LIBs). These post measurements usually require the reassembling of coin-cell with electrode which is often double-side-coated in commercial LIBs. It is difficult to use such double-side-coated electrode to perform accurate electrochemical measurements because the back side of the electrode is coated with active materials, rather than single-side-coated electrode that is often used in coin-cell measurements. In this study, we report a facile tape-covering sample preparation method, which can effectively suppress the influence of back side of the double-side-coated electrodes on capacity and EIS measurements in coin-cells. By tape-covering the unwanted side, the areal capacity of the desired investigated side of the electrode has been accurately measured with an experimental error of about 0.5% at various current densities, and accurate EIS measurements and analysis have been conducted as well.

  14. Circuit Models and Experimental Noise Measurements of Micropipette Amplifiers for Extracellular Neural Recordings from Live Animals

    Directory of Open Access Journals (Sweden)

    Chang Hao Chen

    2014-01-01

    Full Text Available Glass micropipettes are widely used to record neural activity from single neurons or clusters of neurons extracellularly in live animals. However, to date, there has been no comprehensive study of noise in extracellular recordings with glass micropipettes. The purpose of this work was to assess various noise sources that affect extracellular recordings and to create model systems in which novel micropipette neural amplifier designs can be tested. An equivalent circuit of the glass micropipette and the noise model of this circuit, which accurately describe the various noise sources involved in extracellular recordings, have been developed. Measurement schemes using dead brain tissue as well as extracellular recordings from neurons in the inferior colliculus, an auditory brain nucleus of an anesthetized gerbil, were used to characterize noise performance and amplification efficacy of the proposed micropipette neural amplifier. According to our model, the major noise sources which influence the signal to noise ratio are the intrinsic noise of the neural amplifier and the thermal noise from distributed pipette resistance. These two types of noise were calculated and measured and were shown to be the dominating sources of background noise for in vivo experiments.

  15. Respondence Between Electrochemical Fluctuations and Phenomenon for Localized Corrosion of Less-Noble Metals

    International Nuclear Information System (INIS)

    Itoi, Yasuhiko; Take, Seisho; Tsuru, Tooru

    2008-01-01

    We have been studying application of electrochemical noise (Fluctuation) analysis for localized corrosion. Foils of Zinc, Aluminum and Magnesium were used as specimens for electrochemical cell simulating localized corrosion. These specimens were dipped in sodium chloride solutions adjusted to each exponent of hydrogen ion concentration (pH) condition of 5.5, 10, 12 respectively. Time variations of potential and current were measured in those solutions, and simultaneously the surfaces of specimens were observed using microscope with television monitor. Two types of electrochemical cells were arranged for experiments simulated localized corrosion. The fluctuations on trendy component of short-circuited potential and short-circuited current were appeared in synchronization. It was seemed that these fluctuations result from hydrogen evolution on the aluminum active site in the crevice from the microscopic observation. In the case of zinc and magnesium, fluctuations appeared on the trendy component of the corrosion potential. Two types fluctuation were detected. First one is the fluctuation varied periodically. The second one is the random fluctuation. It was seemed that these fluctuations result from generation of corrosion products and hydrogen evolution on the active site in the crevice of zinc and magnesium from the microscopic observation

  16. On-line adaptive line frequency noise cancellation from a nuclear power measuring channel

    Directory of Open Access Journals (Sweden)

    Qadir Javed

    2011-01-01

    Full Text Available On-line software for adaptively canceling 50 Hz line frequency noise has been designed and tested at Pakistan Research Reactor 1. Line frequency noise causes much problem in weak signals acquisition. Sometimes this noise is so dominant that original signal is totally corrupted. Although notch filter can be used for eliminating this noise, but if signal of interest is in close vicinity of 50 Hz, then original signal is also attenuated and hence overall performance is degraded. Adaptive noise removal is a technique which could be employed for removing line frequency without degrading the desired signal. In this paper line frequency noise has been eliminated on-line from a nuclear power measuring channel. The adaptive LMS algorithm has been used to cancel 50 Hz noise. The algorithm has been implemented in labVIEW with NI 6024 data acquisition card. The quality of the acquired signal has been improved much as can be seen in experimental results.

  17. Barkhausen noise measurements give direct observation of magnetocrystalline anisotropy energy in ferromagnetic polycrystals

    International Nuclear Information System (INIS)

    Espina-Hernández, J H; Pérez-Benítez, J A; Caleyo, F; Hallen, J M; Baudin, T; Helbert, A L

    2013-01-01

    This paper presents experimental evidence of the capability of Barkhausen noise measurements to estimate the angular dependence of the average magnetocrystalline energy in soft magnetic polycrystalline materials. Three different API 5L steel samples, all obtained from out-of-service pipelines, were investigated using crystallographic texture and Barkhausen noise measurements. The angular dependence of the rms voltage of the Barkhausen signal was determined in each sample for the time band corresponding to the saturation-to-remanence part of the hysteresis loop where irreversible domain rotation occurs. For each angular position, the rms voltage of the Barkhausen noise signal in this time band was interpreted as a direct measure of the magnetocrystalline anisotropy energy of the polycrystal in the corresponding direction. A strong correlation between the angular dependence of both the rms voltage of the Barkhausen signal in the time band of interest and the average magnetocrystalline energy obtained from crystallographic texture measurements was found experimentally. (fast track communication)

  18. A particle velocity sensor to measure the sound from a structure in the presence of background noise

    NARCIS (Netherlands)

    de Bree, H.E.; Druyvesteyn, W.F.

    2005-01-01

    The performance (or quality) of a product is often checked by measuring the radiated sound (noise) from the vibrating structure. Often this test has to be done in an environment with background noise, which makes the measurement difficult. When using a (pressure) microphone the background noise can

  19. High frequency measurements of shot noise suppression in atomic-scale metal contacts

    Science.gov (United States)

    Wheeler, Patrick J.; Evans, Kenneth; Russom, Jeffrey; King, Nicholas; Natelson, Douglas

    2009-03-01

    Shot noise provides a means of assessing the number and transmission coefficients of transmitting channels in atomic- and molecular-scale junctions. Previous experiments at low temperatures in metal and semiconductor point contacts have demonstrated the expected suppression of shot noise when junction conductance is near an integer multiple of the conductance quantum, G0≡2e^2/h. Using high frequency techniques, we demonstrate the high speed acquisition of such data at room temperature in mechanical break junctions. In clean Au contacts conductance histograms with clear peaks at G0, 2G0, and 3G0 are acquired within hours, and histograms of simultaneous measurements of the shot noise show clear suppression at those conductance values. We describe the dependence of the noise on bias voltage and analyze the noise vs. conductance histograms in terms of a model that averages over transmission coefficients.

  20. Practical Ranges of Loudness Levels of Various Types of Environmental Noise, Including Traffic Noise, Aircraft Noise, and Industrial Noise

    Directory of Open Access Journals (Sweden)

    Sabine A. Janssen

    2011-05-01

    Full Text Available In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A‑weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.

  1. Audible Noise Measurement and Analysis of the Main Power Apparatus in UHV GIS Substations

    Directory of Open Access Journals (Sweden)

    Zhou Nian Guang

    2016-01-01

    Full Text Available Investigation of audible noise characteristics of the main power apparatus in UHV GIS substations provides essential statistics for the noise prediction and control. Noise pressure level, spectrum and attenuation characteristics of the main transformers and high voltage (HV reactors are measured and analyzed in this paper. The result shows that the main transformer and HV reactor have identical A-weighted equivalent sound pressure level. The medium- and low-frequency noises are the primary components in the spectral. More attention should be paid to the low-frequency bands in the noise control process. The noise of cooling fan has a large influence on that of the main transformer. Without the consideration of corona noise, the average A-weighted sound pressure level shows an overall decreasing trend with the increase of the propagation distance. Obvious interference phenomenon of the noises at 100 and 200Hz exists in the noise propagation process.

  2. Development of electronic system for reactivity measurement and reactor noise analysis

    International Nuclear Information System (INIS)

    Strohl, Claude Emile; Soares, Adalberto Jose

    1996-01-01

    In nuclear power reactors, the neutron detector signal is dependent of the number of fissions and the reactor power level. The detector signal can be divided into two components; a DC component, proportional to the average value and an AC component, which is the fluctuating part superimposed to the DC component. The analysis of the fluctuating part of the signal is called noise analysis and allow us to investigate phenomena occurring within the reactor vessel, such as vibration of fuels elements and coolant density, temperature, pressure and flow changes. On the other hand, the measure of the static DC part allow us to measure the local power density. This paper describes the development of a personal computer based signal conditioning card that, together with a personal computer commercial data acquisition card, can be used for noise analysis measurements and reactivity measurements of signals coming from ionization chambers or SPD's. (author)

  3. The Effect of Noise on Relationships Between Speech Intelligibility and Self-Reported Communication Measures in Tracheoesophageal Speakers.

    Science.gov (United States)

    Eadie, Tanya L; Otero, Devon Sawin; Bolt, Susan; Kapsner-Smith, Mara; Sullivan, Jessica R

    2016-08-01

    The purpose of this study was to examine how sentence intelligibility relates to self-reported communication in tracheoesophageal speakers when speech intelligibility is measured in quiet and noise. Twenty-four tracheoesophageal speakers who were at least 1 year postlaryngectomy provided audio recordings of 5 sentences from the Sentence Intelligibility Test. Speakers also completed self-reported measures of communication-the Voice Handicap Index-10 and the Communicative Participation Item Bank short form. Speech recordings were presented to 2 groups of inexperienced listeners who heard sentences in quiet or noise. Listeners transcribed the sentences to yield speech intelligibility scores. Very weak relationships were found between intelligibility in quiet and measures of voice handicap and communicative participation. Slightly stronger, but still weak and nonsignificant, relationships were observed between measures of intelligibility in noise and both self-reported measures. However, 12 speakers who were more than 65% intelligible in noise showed strong and statistically significant relationships with both self-reported measures (R2 = .76-.79). Speech intelligibility in quiet is a weak predictor of self-reported communication measures in tracheoesophageal speakers. Speech intelligibility in noise may be a better metric of self-reported communicative function for speakers who demonstrate higher speech intelligibility in noise.

  4. Increase of Investment Appeal of Projects for Noise Control Measures in Urban Environment

    Science.gov (United States)

    Kolmakov, A. V.; Ignatyeva, V. O.

    2017-11-01

    The authors analyzed the contemporary noise pollution level in the large cities of the Russian Federation. The article identifies the factors causing the reduction of acoustically comfortable urban territories. It states the task for the increase of investment appeal of the projects aimed at noise control measures adoption.

  5. Improvement of the accuracy of noise measurements by the two-amplifier correlation method.

    Science.gov (United States)

    Pellegrini, B; Basso, G; Fiori, G; Macucci, M; Maione, I A; Marconcini, P

    2013-10-01

    We present a novel method for device noise measurement, based on a two-channel cross-correlation technique and a direct "in situ" measurement of the transimpedance of the device under test (DUT), which allows improved accuracy with respect to what is available in the literature, in particular when the DUT is a nonlinear device. Detailed analytical expressions for the total residual noise are derived, and an experimental investigation of the increased accuracy provided by the method is performed.

  6. Acoustic isolation vessel for measurement of the background noise in microphones

    Science.gov (United States)

    Ngo, Kim C. T.; Zuckerwar, Allan J.

    1993-01-01

    An acoustic isolation vessel has been developed to measure the background noise in microphones. The test microphone is installed in an inner vessel, which is suspended within an outer vessel, and the intervening air space is evacuated to a high vacuum. An analytical expression for the transmission coefficient is derived, based on a five-media model, and compared to experiment. At an isolation vacuum of 5 x 10 exp -6 Torr the experimental transmission coefficient was found to be lower than -155 dB at frequencies ranging from 40 to 1200 Hz. Measurements of the A-weighted noise levels of commercial condenser microphones of four different sizes show good agreement with published values.

  7. A low noise preamplifier with optoelectronic overload protection for radioactivity measurement

    International Nuclear Information System (INIS)

    Sephton, J.P.; Williams, J.M.; Johansson, L.C.; Philips, H.C.

    2012-01-01

    Pulses from detectors used for radioactivity measurement can vary in size by several orders of magnitude. Large pulses will lead to saturation at the preamplifier output and extension of the pulse length. As a consequence, the dead time of the system increases and pulses may be lost. Electronic design techniques employed to protect against overloading tend to increase the amplifier noise level. However, an optoelectronic method of overload protection has been devised which has only a negligible effect on noise. An infrared light emitting diode interfaced to the output of the preamplifier is linked by fibre optic cable to an ultra-low leakage photodiode at the input. The conduction of the photodiode increases with the amplitude of the preamplifier output signal. Excess current is thereby prevented from entering the preamplifier and causing saturation. The preamplifier has been tested on 4π beta–gamma and gas counting systems and found to give good protection against overloading. - Highlights: ► A preamplifier for radioactivity measurements has been developed. ► Low noise. ► Current sensitive. ► Optoelectronic overload protection.

  8. Interpenetrating polyaniline-gold electrodes for SERS and electrochemical measurements

    Science.gov (United States)

    West, R. M.; Semancik, S.

    2016-11-01

    Facile fabrication of nanostructured electrode arrays is critical for development of bimodal SERS and electrochemical biosensors. In this paper, the variation of applied potential at a polyaniline-coated Pt electrode is used to selectivity deposit Au on the polyaniline amine sites or on the underlying Pt electrode. By alternating the applied potential, the Au is grown simultaneously from the top and the bottom of the polyaniline film, leading to an interpenetrated, nanostructured polymer-metal composite extending from the Pt electrode to the electrolyte solution. The resulting films have unique pH-dependent electrochemical properties, e.g. they retain electrochemical activity in both acidic and neutral solutions, and they also include SERS-active nanostructures. By varying the concentration of chloroaurate used during deposition, Au nanoparticles, nanodendrites, or nanosheets can be selectively grown. For the films deposited under optimal conditions, using 5 mmol/L chloroaurate, the SERS enhancement factor for Rhodamine 6G was found to be as high as 1.1 × 106 with spot-to-spot and electrode-to-electrode relative standard deviations as low as 8% and 12%, respectively. The advantages of the reported PANI-Au composite electrodes lie in their facile fabrication, enabling the targeted deposition of tunable nanostructures on sensing arrays, and their ability to produce orthogonal optical and electrochemical analytical results.

  9. Measurement of speech levels in the presence of time varying background noise

    Science.gov (United States)

    Pearsons, K. S.; Horonjeff, R.

    1982-01-01

    Short-term speech level measurements which could be used to note changes in vocal effort in a time varying noise environment were studied. Knowing the changes in speech level would in turn allow prediction of intelligibility in the presence of aircraft flyover noise. Tests indicated that it is possible to use two second samples of speech to estimate long term root mean square speech levels. Other tests were also performed in which people read out loud during aircraft flyover noise. Results of these tests indicate that people do indeed raise their voice during flyovers at a rate of about 3-1/2 dB for each 10 dB increase in background level. This finding is in agreement with other tests of speech levels in the presence of steady state background noise.

  10. Distortions of the statistical distribution of Barkhausen noise measured by magneto-optical Kerr effect

    International Nuclear Information System (INIS)

    Pinotti, E.; Brenna, M.; Puppin, E.

    2008-01-01

    In magneto-optical Kerr measurements of the Barkhausen noise, a magnetization jump ΔM due to a domain reversal produces a variation ΔI of the intensity of a laser beam reflected by the sample, which is the physical quantity actually measured. Due to the non-uniform beam intensity profile, the magnitude of ΔI depends both on ΔM and on its position on the laser spot. This could distort the statistical distribution p(ΔI) of the measured ΔI with respect to the true distribution p(ΔM) of the magnetization jumps ΔM. In this work the exact relationship between the two distributions is derived in a general form, which will be applied to some possible beam profiles. It will be shown that in most cases the usual Gaussian beam produces a negligible statistical distortion. Moreover, for small ΔI the noise of the experimental setup can also distort the statistical distribution p(ΔI), by erroneously rejecting small ΔI as noise. This effect has been calculated for white noise, and it will be shown that it is relatively small but not totally negligible as the measured ΔI approaches the detection limit

  11. Impact of non-white noises in pulse amplitude measurements: a time-domain approach

    International Nuclear Information System (INIS)

    Pullia, A.

    1998-01-01

    The contribution of the 1/f-noise to the spectral line broadening in pulse amplitude measurements is derived with a time-domain analysis. The known time-domain relationships which provide the contributions of the series and parallel white noises are generalised for the case of 1/f and other typical non-white noises, by using the fractional derivative of either the system impulse response (time-invariant linear filters) or its weight function folded (time-variant linear filters). It is shown that a time-domain approach is also effective to determine the contribution of Lorentzian noises. A simple rule suitable to derive numerically the fractional derivative is given, which permits to calculate the effect of non-white noises even when the filter impulse response is not known analytically but only in sampled form. (orig.)

  12. Current Mode Neutron Noise Measurements in the Zero Power Reactor CROCUS

    Science.gov (United States)

    Pakari, O.; Lamirand, V.; Perret, G.; Braun, L.; Frajtag, P.; Pautz, A.

    2018-01-01

    The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / λ, the effective delayed neutron fraction βeff, and the mean generation time λ for code validation efforts. At higher detection rates, i.e. above 2×104 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated 10B-coated ionization chambers available in CROCUS as operational monitors. The compensated current signal of these chambers was extracted from coremonitoring output channels. 2) By developing a new current mode amplification station to be used with other available detectors in core. Characteristics and first noise measurements of the new current system are presented. We implemented post-processing of the current signals from 1)and 2) with the APSD/CPSD method to determine α. At two critical states (0.5 and 1.5 W), using the 10B ionization chambers and their CPSD estimate, the prompt decay constant was measured after 1.5 hours to be α=(156.9 ± 4.3) s-1 (1σ). This result is within 1σ of statistical uncertainties of previous experiments and MCNPv5-1.6 predictions using the ENDF/B-7.1 library. The newsystem connected to a CFUL01 fission chamber using the APSDestimate at 100 mW after 33 min yielded α = (160.8 ± 6.3) s-1, also within 1σ agreement. The improvements to previous neutron noise

  13. Simulated dose reduction by adding artificial noise to measured raw data: A validation study

    International Nuclear Information System (INIS)

    Soederberg, M.; Gunnarsson, M.; Nilsson, M.

    2010-01-01

    The purpose of this study was to verify and validate a noise simulation tool called Dose Tutor (VAMP GmbH) in terms of level and texture of the simulated noise. By adding artificial noise to measured computed tomography (CT) raw data, a scan acquired with a lower dose (mAs) than the actual one can be simulated. A homogeneous polyethylene phantom and an anthropomorphic chest phantom were scanned for different mAs levels, tube voltages, slice thicknesses and reconstruction kernels. The simulated noise levels were compared with the noise levels in real transverse slice images actually acquired with corresponding mAs values. In general, the noise comparisons showed acceptable agreement in magnitude (<20% deviation in pixel standard deviation). Also, the calculated noise power spectra were similar, which indicates that the noise texture is correctly reproduced. In conclusion, this study establishes that the Dose Tutor might be a useful tool for estimating the dose reduction potential for CT protocols. (authors)

  14. Electrochemical gating in scanning electrochemical microscopy

    NARCIS (Netherlands)

    Ahonen, P.; Ruiz, V.; Kontturi, K.; Liljeroth, P.; Quinn, B.M.

    2008-01-01

    We demonstrate that scanning electrochemical microscopy (SECM) can be used to determine the conductivity of nanoparticle assemblies as a function of assembly potential. In contrast to conventional electron transport measurements, this method is unique in that electrical connection to the film is not

  15. Electrochemical potential measurements in boiling water reactors; relation to water chemistry and stress corrosion

    International Nuclear Information System (INIS)

    Indig, M.E.; Cowan, R.L.

    1981-01-01

    Electrochemical potential measurements were performed in operating boiling water reactors to determine the range of corrosion potentials that exist from cold standby to full power operation and the relationship of these measurements to reactor water chemistry. Once the corrosion potentials were known, experiments were performed in the laboratory under electrochemical control to determine potentials and equivalent dissolved oxygen concentrations where intergranular stress corrosion cracking (IGSCC) would and would not occur on welded Type-304 stainless steel. At 274 0 C, cracking occurred at potentials that were equivalent to dissolved oxygen concentration > 40 to 50 ppb. With decreasing temperature, IGSCC became more difficult and only severely sensitized stainless steel would crack. Recent in-reactor experiments combined with the previous laboratory data, have shown that injection of small concentrations of hydrogen during reactor operation can cause a significant decrease in corrosion potential which should cause immunity to IGSCC. (author)

  16. Joint Neutron Noise Measurements on Metallic Reactor Caliban

    International Nuclear Information System (INIS)

    Chapelle, Amaury; Authier, Nicolas; Pierre, Casoli; Richard, Benoit; Myers, Will; Hutchinson, Jesson; Sood, Avneet; Rooney, Brian

    2013-06-01

    The aim of the experiments concerning neutron noise measurements presented in this article is to compare the measured parameters to the simulated ones. The results of these measurements must therefore be very accurate, with controlled uncertainties. To determine the relative contribution of uncertainties to the final result, a table presents the prompt multiplication obtained by a French Team and a U.S. team. The different sources of uncertainties are then explored, distinguishing them between three categories, those linked to the experimental configuration, to the detection process and finally to the analysis process. These experiments improve the safety task of reactivity control far from criticality, with static methods, and the knowledge of the behaviour of a subcritical reactor. (authors)

  17. Signal Processing for the Impedance Measurement on an Electrochemical Generator

    Directory of Open Access Journals (Sweden)

    El-Hassane AGLZIM

    2008-04-01

    Full Text Available Improving the life time of batteries or fuel cells requires the optimization of components such as membranes and electrodes and enhancement of the flow of gases [1], [2]. These goals could be reached by using a real time measurement on loaded generator. The impedance spectroscopy is a new way that was recently investigated. In this paper, we present an electronic measurement instrumentation developed in our laboratory to measure and plot the impedance of a loaded electrochemical generator like batteries and fuel cells. Impedance measures were done according to variations of the frequency in a larger band than what is usually used. The electronic instrumentation is controlled by Hpvee® software which allows us to plot the Nyquist graph of the electrochemical generator impedance. The theoretical results obtained in simulation under Pspice® confirm the choice of the method and its advantage. For safety reasons, the experimental preliminary tests were done on a 12 V vehicle battery, having an input current of 330 A and a capacity of 40 Ah and are now extended to a fuel cell. The results were plotted at various nominal voltages of the battery (12.7 V, 10 V, 8 V and 5 V and with two imposed currents (0.6 A and 4 A. The Nyquist diagram resulting from the experimental data enable us to show an influence of the load of the battery on its internal impedance. The similitude in the graph form and in order of magnitude of the values obtained (both theoretical and practical enables us to validate our electronic measurement instrumentation. Different sensors (temperature, pressure were placed around the device under test (DUT. These influence parameters were permanently recorded. Results presented here concern a classic loaded 12 V vehicle battery. The Nyquist diagram resulting from the experimental data confirms the influence of the load of the DUT on its internal impedance.

  18. Sounds and Noises. A Position Paper on Noise Pollution.

    Science.gov (United States)

    Chapman, Thomas L.

    This position paper focuses on noise pollution and the problems and solutions associated with this form of pollution. The paper is divided into the following five sections: Noise and the Ear, Noise Measurement, III Effects of Noise, Acoustics and Action, and Programs and Activities. The first section identifies noise and sound, the beginnings of…

  19. Noise temperature measurements for the determination of the thermodynamic temperature of the melting point of palladium

    Energy Technology Data Exchange (ETDEWEB)

    Edler, F.; Kuhne, M.; Tegeler, E. [Bundesanstalt Physikalisch-Technische, Berlin (Germany)

    2004-02-01

    The thermodynamic temperature of the melting point of palladium in air was measured by noise thermometric methods. The temperature measurement was based on noise comparison using a two-channel arrangement to eliminate parasitic noises of electronic components by cross correlation. Three miniature fixed points filled with pure palladium (purity: {approx}99.99%, mass: {approx}90 g) were used to realize the melts of the fixed point metal. The measured melting temperature of palladium in air amounted to 1552.95 deg C {+-} 0.21 K (k = 2). This temperature is 0.45 K lower than the temperature of the melting point of palladium measured by radiation thermometry. (authors)

  20. Accuracy of signal-to-noise ratio measurement method for magnetic resonance images

    International Nuclear Information System (INIS)

    Ogura, Akio; Miyai, Akira; Maeda, Fumie; Fukutake, Hiroyuki; Kikumoto, Rikiya

    2003-01-01

    The signal-to-noise ratio (SNR) of a magnetic resonance image is a common measure of imager performance. However, evaluations for the calculation of the SNR use various methods. A problem with measuring SNR is caused by the distortion of noise statistics in commonly used magnitude images. In this study, measurement accuracy was compared among four methods of evaluating SNR according to the size and position of regions of interest (ROIs). The results indicated that the method that used the difference between two images showed the best agreement with the theoretical value. In the method that used a single image, the SNR calculated by using a small size of ROI showed better agreement with the theoretical value because of noise bias and image artifacts. However, in the method that used the difference between two images, a large size of ROI was better in reducing statistical errors. In the same way, the methods that used air noise and air signal were better when applied to a large ROI. In addition, the image subtraction process used to calculate pixel-by-pixel differences in images may reach zero on a minus pixel value when using an image processor with the MRI system and apparatuses associated with it. A revised equation is presented for this case. It is important to understand the characteristics of each method and to choose a suitable method carefully according to the purpose of the study. (author)

  1. Measurement of Underwater Operational Noise Emitted by Wave and Tidal Stream Energy Devices.

    Science.gov (United States)

    Lepper, Paul A; Robinson, Stephen P

    2016-01-01

    The increasing international growth in the development of marine and freshwater wave and tidal energy harvesting systems has been followed by a growing requirement to understand any associated underwater impact. Radiated noise generated during operation is dependent on the device's physical properties, the sound-propagation environment, and the device's operational state. Physical properties may include size, distribution in the water column, and mechanics/hydrodynamics. The sound-propagation environment may be influenced by water depth, bathymetry, sediment type, and water column acoustic properties, and operational state may be influenced by tidal cycle and wave height among others This paper discusses some of the challenges for measurement of noise characteristics from these devices as well as a case study of the measurement of radiated noise from a full-scale wave energy converter.

  2. Charting environmental pollution. [by noise measurements

    Science.gov (United States)

    Halpert, E.; Bizo, F.; Karacsonyi, Z.

    1974-01-01

    It is found that areas affected by different noxious agents are within the limits traced for high noise level areas; consequently, it is suggested that high noise pressure levels should be used as the primary indication of environmental pollution. A complex methodology is reported for charting environmental pollution due to physical, chemical and biological noxious agents on the scale of an industrial district.

  3. Noise and specific detectivity measurements on high-temperature superconducting transition-edge bolometers

    International Nuclear Information System (INIS)

    Black, R.D.; Mogro-campero, A.; Turner, L.G.

    1990-01-01

    The effects of thermal fluctuation noise in thermal detectors can be lessened by reducing heat capacity and thermal conductance. An attempt to accomplish this with the YBa2Cu3O(7-x) (YBCO) bolometer by making YBCO resistors on thermally isolated membranes is reported. The spectral power of the electrical noise of YBCO films on SrTiO3, bulk silicon with a buffer layer, and in thin dielectric membranes is measured. It is found that 1/f noise predominates in polycrystalline YBCO films on silicon-based substrates. Films on SrTiO3 with good electrical properties are dominated by thermal fluctuation noise, just as in the case of low-temperature superconductors. The implications of these findings for bolometer are addressed. The specific detectivity of a bolometric pixel made on bulk SrTiO3 is reported. 14 refs

  4. Judgments of aircraft noise in a traffic noise background

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1975-01-01

    An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.

  5. 40 CFR 201.23 - Test site, weather conditions and background noise criteria for measurement at a 30 meter (100...

    Science.gov (United States)

    2010-07-01

    ... background noise criteria for measurement at a 30 meter (100 feet) distance of the noise from locomotive and... and background noise criteria for measurement at a 30 meter (100 feet) distance of the noise from... meters (4 feet) above the ground at the microphone location, except as provided in paragraph (c) of this...

  6. Measurement of two-phase flow variables in a BWR by analysis of in-core neutron detector noise signals

    International Nuclear Information System (INIS)

    Stekelenburg, A.J.C.; Hagen, T.H.J.J. van der

    1996-01-01

    In this paper, the state of the art of the measurement of two-phase flow variables in a boiling water reactor (BWR) by analysis of in-core neutron detector noise signals is given. It is concluded that the neutronic processes involved in neutron noise are quite well understood, but that little is known about the density fluctuations in two-phase flow which are the main cause of the neutron noise. For this reason, the neutron noise measurements, like the well known two-detector velocity measurements, are still difficult to interpret. By analyzing neutron noise measurements in a natural circulation cooled BWR, it is illustrated that, once a theory on the density fluctuations is developed, two-phase flow can be monitored with a single in-core detector. (author). 70 refs, 4 figs

  7. Ground noise measurements during static and flyby operations of the Cessna 02-T turbine powered airplane

    Science.gov (United States)

    Hilton, D. A.; Henderson, H. R.; Lawton, B. W.

    1975-01-01

    The field noise measurements on the Cessna 02-T turbine powered propeller aircraft are presented. The objective of the study was to obtain the basic noise characteristics of the aircraft during static ground runs and flyover tests, to identify the sources of the noise, and to correlate the noises with the aircraft operating conditions. The results are presented in the form of a overall noise levels, radiation patterns, and frequency spectra. The noise characteristics of the turbine powered aircraft are compared with those of the reciprocating engine powered aircraft.

  8. Two-detector cross-correlation noise technique and its application in measuring reactor kinetic parameters

    International Nuclear Information System (INIS)

    Lu Guiping; Peng Feng; Yi Jieyi

    1988-01-01

    The two-detector cross-correlation noise technique is a new method of measuring reactor kinetic parameters developed in the sixties. It has the advantages of non-perturbation in core, high signal to noise ratio, low space dependent effect, and simple and reliable in measurement. A special set of cross-correlation analyzer has been prepared for measuring kinetic parameters of several reactor assemblies, such as the High Flux Engineering Test Reactor, its zero power mock up facility and a low enriched uranium light water lattice zero power facility

  9. Measurements of kinetic parameters by noise techniques on the MINERVE reactor

    International Nuclear Information System (INIS)

    Carre, J.C.; Da Costa Oliveira, J.

    1975-01-01

    Noise measurements were determined on ERMINE a fast thermal coupled reactor built in MINERVE. A reactor without feedback, and a reactor with an automatic control rod were both considered. The first case concerned the measurements of auto and cross power spectral density obtained with one or two neutron detectors, and the determination of: neutron lifetime; efficiency for one ion chamber; power level of the reactor; maximal speed and acceleration of the control rod for the design of an automatic reactor control actuator. The second case was concerned with measurements of the auto power spectral density in reactivity for the control rod, and the estimation of: the transfer function of the automatic pilot; the neutron lifetime; and the standard error affecting the results obtained by the oscillation method. The results proved that the pile noise theory with a point kinetic model is sufficient for application on zero power reactors. (U.K.)

  10. A portable measurement system for subcriticality measurements by the Cf-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1987-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the 252 Cf-source-driven neutron noise analysis method. 8 refs

  11. On measurement noise in the European TWSTFT network.

    Science.gov (United States)

    Piester, Dirk; Bauch, Andreas; Becker, Jürgen; Staliuniene, Egle; Schlunegger, Christian

    2008-09-01

    Two-way satellite time and frequency transfer (TWSTFT) using geostationary telecommunication satellites is widely used in the timing community today and has also been chosen as the primary means to effect synchronization of elements of the ground segment of the European satellite navigation system Galileo. We investigated the link performance in a multistation network based on operational parameters such as the number of simultaneously transmitting stations, transmit and receive power, and chip rates of the pseudorandom noise modulation of the transmitted signals. Our work revealed that TWSTFT through a "quiet" transponder channel (2 stations transmitting only) leads to a measurement noise, expressed by the 1 pps jitter, reduced by a factor of 1.4 compared with a busy transponder carrying signals of 12 stations. The frequency transfer capability expressed by the Allan deviation is reduced at short averaging times by the same amount. At averaging times of >1 d, no such reduction could be observed, which points to the fact that other noise sources dominate at such averaging times. We also found that higher transmit power increases the carrier-to-noise density ratio at the receive station and thus entails lower jitter but causes interference with other station's signals. In addition, the use of lower chip rates, which could be accommodated by a reduced assigned bandwidth on the satellite transponder, is not recommended. The 1 pps jitter would go up by a factor of 2.5 when going from 2.5 MCh/s to 1 MCh/s. The 2 Galileo precise timing facilities (PTFs) can be included in the currently operated network of 12 stations in Europe and all requirements on the TWSTFT performance can be met, provided that suitable ground equipment will be installed in the Galileo ground segment.

  12. Electrochemical force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Sergei V.; Jesse, Stephen; Collins, Liam F.; Rodriguez, Brian J.

    2017-01-10

    A system and method for electrochemical force microscopy are provided. The system and method are based on a multidimensional detection scheme that is sensitive to forces experienced by a biased electrode in a solution. The multidimensional approach allows separation of fast processes, such as double layer charging, and charge relaxation, and slow processes, such as diffusion and faradaic reactions, as well as capturing the bias dependence of the response. The time-resolved and bias measurements can also allow probing both linear (small bias range) and non-linear (large bias range) electrochemical regimes and potentially the de-convolution of charge dynamics and diffusion processes from steric effects and electrochemical reactivity.

  13. Handbook Of Noise And Vibration

    International Nuclear Information System (INIS)

    1995-12-01

    This book is about noise and vibration. The first chapter has explanations of noise such as basic of sound, influence of noise, assessment of noise, measurement of prevention of noise and technology, case of noise measurement and soundproof. The second chapter describes vibration with outline, theory of vibration, interpretation of vibration, measurement for reduction of vibration, case of design of protection against vibration. It deals with related regulation and method of measurement.

  14. Noise resistance applied to the study paints

    International Nuclear Information System (INIS)

    Lanchas Garcia-Zarco, S.; Alfosin Perez, V.; Suarez Garcia, A.; Urrejola Madrinan, S.; Sanchez Bermudez, A.

    2015-01-01

    Electrochemical noise is one of the methods of analysis used to interpret the phenomenon of corrosion. It has a number of advantages over other methodology types including its simplicity, its low cost and the fact that it does not disturb the system. This methodology appears to be effective together with other techniques in metal-electrolyte systems. In this case the technique is applied on its own on commercial anti-corrosion paints for which no information is available from other techniques. The main result of this study reveals the effectiveness of the noise resistance parameter, which had already been tested in the lab, when it is used to explain how the paint system behaves in industry. (Author)

  15. An electrochemical hydrogen meter for measuring hydrogen in sodium using a ternary electrolyte mixture

    CERN Document Server

    Sridharan, R; Nagaraj, S; Gnanasekaran, T; Periaswami, G

    2003-01-01

    An electrochemical sensor for measuring hydrogen concentration in liquid sodium that is based on a ternary mixture of LiCl, CaCl sub 2 and CaHCl as the electrolyte has been developed. DSC experiments showed the eutectic temperature of this ternary system to be approx 725 K. Impedance spectroscopic analysis of the electrolyte indicated ionic conduction through a molten phase at approx 725 K. Two electrochemical hydrogen sensors were constructed using the ternary electrolyte of composition 70 mol% LiCl:16 mol% CaHCl:14 mol% CaCl sub 2 and tested at 723 K in a mini sodium loop and at hydrogen levels of 60-250 ppb in sodium. The sensors show linear response in this concentration range and are capable of detecting a change of 10 ppb hydrogen in sodium over a background level of 60 ppb. Identification of this electrolyte system and its use in a sensor for measuring hydrogen in sodium are described in this paper.

  16. Automated system for equivalent noise charge measurements from 10 ns to 10 μs

    International Nuclear Information System (INIS)

    La Taille, C. de.

    1992-07-01

    Noise measurements versus filter time constant constitute a very powerful method to investigate series, parallel and 1/f noise contributions in front end electronics. Usually performed with a set of filters and a multichannel analyser, they are tedious and often limited to values greater than 100 ns. A very low noise bipolar filter is described whose time constant can be selected via GPIB bus from 10 ns to 10 μs in 10 steps. The data are transferred from a digital scope to a computer which generates a baseline histogram and determines the overall gain. The Equivalent Noise Charge is then calculated for each time constant and a fit to the results determines the various noise parameters. (author) 13 refs., 10 figs., 1 tab

  17. Electrochemical measurements and modeling predictions in boiling water reactors under various operating conditions

    International Nuclear Information System (INIS)

    Indig, M.E.

    1991-01-01

    One important issue for providing life extension to operating boiling water nuclear reactors (BWRs) is the control of stress corrosion cracking in all sections of the primary coolant circuit. This paper links experimental and theoretical methods that provide understanding and measurements of the critical parameter, the electrochemical potential (ECP), and its application to determining crack growth rate among and within the family of BWRs. Measurement of in-core ECP required the development of a new family of radiation-resistant sensors. With these sensors, ECPs were measured in the core and piping of two operating BWRs. Concurrent crack growth measurements were used to benchmark a crack growth prediction algorithm with measured ECPs

  18. Measurement of the Boltzmann constant by Johnson noise thermometry using a superconducting integrated circuit

    Science.gov (United States)

    Urano, C.; Yamazawa, K.; Kaneko, N.-H.

    2017-12-01

    We report on our measurement of the Boltzmann constant by Johnson noise thermometry (JNT) using an integrated quantum voltage noise source (IQVNS) that is fully implemented with superconducting integrated circuit technology. The IQVNS generates calculable pseudo white noise voltages to calibrate the JNT system. The thermal noise of a sensing resistor placed at the temperature of the triple point of water was measured precisely by the IQVNS-based JNT. We accumulated data of more than 429 200 s in total (over 6 d) and used the Akaike information criterion to estimate the fitting frequency range for the quadratic model to calculate the Boltzmann constant. Upon detailed evaluation of the uncertainty components, the experimentally obtained Boltzmann constant was k=1.380 6436× {{10}-23} J K-1 with a relative combined uncertainty of 10.22× {{10}-6} . The value of k is relatively -3.56× {{10}-6} lower than the CODATA 2014 value (Mohr et al 2016 Rev. Mod. Phys. 88 035009).

  19. Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography.

    Science.gov (United States)

    Okawa, S; Endo, Y; Hoshi, Y; Yamada, Y

    2012-01-01

    A method to reduce noise for time-domain diffuse optical tomography (DOT) is proposed. Poisson noise which contaminates time-resolved photon counting data is reduced by use of maximum a posteriori estimation. The noise-free data are modeled as a Markov random process, and the measured time-resolved data are assumed as Poisson distributed random variables. The posterior probability of the occurrence of the noise-free data is formulated. By maximizing the probability, the noise-free data are estimated, and the Poisson noise is reduced as a result. The performances of the Poisson noise reduction are demonstrated in some experiments of the image reconstruction of time-domain DOT. In simulations, the proposed method reduces the relative error between the noise-free and noisy data to about one thirtieth, and the reconstructed DOT image was smoothed by the proposed noise reduction. The variance of the reconstructed absorption coefficients decreased by 22% in a phantom experiment. The quality of DOT, which can be applied to breast cancer screening etc., is improved by the proposed noise reduction.

  20. Background- and simulated leak-noise measurements on ASB-loop, KNK II- and SNR 300-steam generators

    International Nuclear Information System (INIS)

    Voss, J.; Arnaoutis, N.; Foerster, K.; Moellerfeld, H.

    1990-01-01

    During several leak propagation experiments in the ASB sodium loop noise measurements were performed showing the acoustic behaviour of evoluting leaks in a tube bundle section under sodium. Effects like self evolution, secondary leaks and tube ruptures by overheating occurred during these tests and were reflected in the course of acoustic signals. In one of the KNK II steam generators simulated leak noise was detected against background noise throughout the operating power range. Experimental arrangements and results are described. In SNR 300 all of the SGUs are equipped with waveguides and some with accelerometers for background noise measurements. First measurement under isothermal conditions were performed in the past. A gas injection device for acoustic leak simulation is under construction. The design of the experimental acoustic system and first results are presented. (author). 1 ref., 21 figs, 2 tabs

  1. β-Cyclodextrin polymer functionalized reduced-graphene oxide: Application for electrochemical determination imidacloprid

    International Nuclear Information System (INIS)

    Chen, Ming; Meng, Yang; Zhang, Wang; Zhou, Jun; Xie, Ju; Diao, Guowang

    2013-01-01

    Highlights: • β-CDP/rGO nanocomposites were prepared by a facile strategy. • β-CDP/rGO nanocomposites displayed the excellent water-dispersity and stability. • β-CDP/rGO exhibited high supramolecular recognition and enrichment capability. • β-CDP/rGO electrode showed excellent electrochemical performance for IDP. -- Abstract: Reduced-graphene oxide (rGO) modified with water-soluble β-cyclodextrin polymer (β-CDP) were successfully prepared by using a simple wet chemical strategy. The obtained β-CDP/rGO nanocomposites were characterized by Fourier transform infrared spectroscopy (FTIR), static contact angle measurement, thermogravimetric analysis (TGA), scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS), which confirmed that β-CDP molecules had been effectively loaded onto the surface of rGO. β-CDP/rGO nanocomposites displayed the excellent water-dispersity and stability. More significantly, cyclic voltammetry and differential pulse voltammetry measurement showed that the β-CDP/rGO could exhibit high supramolecular recognition and enrichment capability, and consequently display excellent electrochemical response toward a pesticide-imidacloprid (IDP). As compared with various modified electrodes, β-CDP/rGO modified glassy carbon electrode exhibited an excellent electrochemical performance for IDP. Based on the cyclic voltammograms (CV) of different concentration of IDP at pH 6.8, the detection line range of IDP is 1 × 10 −6 to 1.5 × 10 −4 mol L −1 IDP and the detection limit is 1 × 10 −7 mol L −1 . Differential pulse voltammetry (DPV) measurement at β-CDP/rGO/GCE modified electrode revealed that the reduction peak current increased linearly with the concentration of IDP in linear range of 5 × 10 −8 to 1.5 × 10 −5 mol L −1 and 2 × 10 −5 to 1.5 × 10 −4 mol L −1 with detection limit of 2 × 10 −8 mol L −1 at a signal-to-noise ratio of 3

  2. Improved Kalman Filter Method for Measurement Noise Reduction in Multi Sensor RFID Systems

    Directory of Open Access Journals (Sweden)

    Min Chul Kim

    2011-10-01

    Full Text Available Recently, the range of available Radio Frequency Identification (RFID tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less Mean Squared Error (MSE than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments.

  3. Improved Kalman filter method for measurement noise reduction in multi sensor RFID systems.

    Science.gov (United States)

    Eom, Ki Hwan; Lee, Seung Joon; Kyung, Yeo Sun; Lee, Chang Won; Kim, Min Chul; Jung, Kyung Kwon

    2011-01-01

    Recently, the range of available radio frequency identification (RFID) tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less mean squared error (MSE) than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments.

  4. Standard practice for calculation of corrosion rates and related information from electrochemical measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This practice covers the providing of guidance in converting the results of electrochemical measurements to rates of uniform corrosion. Calculation methods for converting corrosion current density values to either mass loss rates or average penetration rates are given for most engineering alloys. In addition, some guidelines for converting polarization resistance values to corrosion rates are provided. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  5. Capture dynamics of hot electrons on quantum dots in RTDs studied by noise measurement

    International Nuclear Information System (INIS)

    Hees, S S; Kardynal, B E; Shields, A J; Farrer, I; Ritchie, D A

    2008-01-01

    We investigate the noise in quantum dot resonant tunnelling diodes (QDRTDs), where the quantum dots (QDs) placed in the collector experience electric fields that vary in a wide range. The trapping/detrapping of electrons on the QDs dominated the measured electrical noise. The model that we derived for the noise explains the experimental data well. The QD capture cross-section is one to two orders of magnitude smaller than the physical size of the QDs due to the reduced probability of capturing a hot electron on the QD. The model is a powerful tool to design the noise characteristics of QDRTD single photon-detectors

  6. Quantitative Measures of Anthropogenic Noise on Harbor Porpoises

    DEFF Research Database (Denmark)

    Wisniewska, Danuta Maria; Teilmann, Jonas; Hermannsen, Line

    2016-01-01

    -animal recordings as proxies for actual exposure. Here, we quantify sound exposure levels recorded with a DTAG-3 tag on a captive harbor porpoise exposed to vessel noise in a controlled acoustic environment. Results show that fl ow noise is limiting onboard noise recordings, whereas no evidence of body shading has...

  7. Signals and noise in measurements of low-frequency geomagnetic fields

    International Nuclear Information System (INIS)

    Nichols, E.A.; Morrison, H.F.; Clarke, J.

    1988-01-01

    The apparent magnetic noise, obtained from the coherency function for two parallel magnetic sensors, generally overstimates sensor noise because the sensors do not measure the same signal. The different signals result from the nonparallel alignment of the sensors and from the additional magnetic signal induced in each sensor by its motion in the Earth's magnetic field. A magnetometer array experiment was completed in Grass Valley, Nevada, to determine the minimum magnetic signal that could be detected in the presence of background natural field variations and motion of the sensor. Superconducting quantum interference device (SQUID) magnetometers with interval biaxial tiltmeters were used to record the magnetic fields and the motion of the sensors

  8. In-Channel-Grown Polypyrrole Nanowire for the Detection of DNA Hybridization in an Electrochemical Microfluidic Biosensor

    Directory of Open Access Journals (Sweden)

    Thi Luyen Tran

    2015-01-01

    Full Text Available A triple electrode setup with a Pt pseudo-reference electrode integrated in a polydimethylsiloxane- (PDMS- based microchamber was designed and fabricated. The integrated electrodes were deposited onto SiO2/Si substrate by sputtering. The PDMS microchamber was patterned using an SU-8 mold and sealed with electrodes in oxygen plasma. Polypyrrole nanowires (PPy NWs were electrochemically grown in situ at an accurate position of the working electrode in the sealed microchamber instead of in an open system. The DNA probe sequences were simply introduced into the channel to form bonds with the nanowires. A detection limit of 20 pM was achieved using a lock-in amplifier. The electrochemical characteristics produced by the hybridization of DNA strands in the microchamber showed a good signal/noise ratio and high sensitivity. Measurement of the DNA sensor in narrow space also required much less volume of the analytical sample compared with that in an open measuring cell. Results showed that this simple system can potentially fabricate nanostructures and detect bio/chemical molecules in a sealed system.

  9. A simplified, improved method for making amplifier equivalent noise charge measurements using a new generation digitizing oscilloscope

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1990-10-01

    Historically a variety of methods have been used to measure the equivalent noise charge (ENC) of amplifier/shaper systems for high energy physics. Some of these methods require several pieces of special test equipment and a fair amount of effort. The advent of digitizing oscilloscopes with statistics capabilities makes it possible to perform certain types of noise measurements accurately with very little effort. This paper describes the noise measurement method of a time invariant amplifier/shaper and of a time variant correlated sampling system, using a Tektronix DSA602 Digitizing Signal Analyzer. 4 figs

  10. Urban traffic noise assessment by combining measurement and model results

    NARCIS (Netherlands)

    Eerden, F.J.M. van der; Graafland, F.; Wessels, P.W.; Basten, T.G.H.

    2013-01-01

    A model based monitoring system is applied on a local scale in an urban area to obtain a better understanding of the traffic noise situation. The system consists of a scalable sensor network and an engineering model. A better understanding is needed to take appropriate and cost efficient measures,

  11. A statistical background noise correction sensitive to the steadiness of background noise.

    Science.gov (United States)

    Oppenheimer, Charles H

    2016-10-01

    A statistical background noise correction is developed for removing background noise contributions from measured source levels, producing a background noise-corrected source level. Like the standard background noise corrections of ISO 3741, ISO 3744, ISO 3745, and ISO 11201, the statistical background correction increases as the background level approaches the measured source level, decreasing the background noise-corrected source level. Unlike the standard corrections, the statistical background correction increases with steadiness of the background and is excluded from use when background fluctuation could be responsible for measured differences between the source and background noise levels. The statistical background noise correction has several advantages over the standard correction: (1) enveloping the true source with known confidence, (2) assuring physical source descriptions when measuring sources in fluctuating backgrounds, (3) reducing background corrected source descriptions by 1 to 8 dB for sources in steady backgrounds, and (4) providing a means to replace standardized background correction caps that incentivize against high precision grade methods.

  12. Noise and its application to neutron flux measurements

    International Nuclear Information System (INIS)

    Sabate Puigmal, Pedro.

    1984-08-01

    Fission Counter's (FC) fundamental principles were studied, operating this neutron detector as pulses generator (AC modes) and fluctuant current (DC modes). Power spectral series were obtained in DC modes, corresponding to: alpha activity of the FC neutron converter, gamma exposition in Co 60 radiation field, and only neutronic field. These noise spectra were correlated with those obtained from the FC in RA-3 critical facility, at different reactor power levels. These experiments allow to verify that, in DC mode, the power noise is very weakly dependent of the reactor gamma field, over a wide range of reactor working power, and that this range is strongly dependent of the detector's position with respect to the core's position. The frequency band of measurement is not critical. The results suggest that it is possible to develop a simple and compact measurement chain for nuclear reactors control. This would be obtained with an adequate combination of the FC operation ranges in AC and DC modes. Approximately ten decades in working power would be thus controlled with this unique type of detector (Campbellian method). A locally devised commercial detector (CFPT9) was used in these tests, and several of the most useful positions of the FC were determined. Frequency band from 150 Hz to 150 KHz was investigated. (M.E.L.) [es

  13. The Analysis of Low Noise Protection Barriers Influence on Tram Traffic Noise Levels

    Directory of Open Access Journals (Sweden)

    Ahac Maja

    2013-07-01

    Full Text Available The paper describes the analysis of tram traffic noise situation in residential areas in the vicinity of Drzic Avenue, one of the major routes between the northern and southern part of the Croatian capital city Zagreb, and the effect of low barriers placed by the tracks on tram noise mitigation. In order to evaluate the effect of planned protection measure, noise models were produced and verified with short-term field measurements. Calculations were conducted by means of noise prediction software, using European interim noise prediction method and 3D model of analyzed area. Finally, the results of noise calculations for existing tram traffic situation and planned measure of protection are presented on noise maps.

  14. Using hyperentanglement to enhance resolution, signal-to-noise ratio, and measurement time

    Science.gov (United States)

    Smith, James F.

    2017-03-01

    A hyperentanglement-based atmospheric imaging/detection system involving only a signal and an ancilla photon will be considered for optical and infrared frequencies. Only the signal photon will propagate in the atmosphere and its loss will be classical. The ancilla photon will remain within the sensor experiencing low loss. Closed form expressions for the wave function, normalization, density operator, reduced density operator, symmetrized logarithmic derivative, quantum Fisher information, quantum Cramer-Rao lower bound, coincidence probabilities, probability of detection, probability of false alarm, probability of error after M measurements, signal-to-noise ratio, quantum Chernoff bound, time-on-target expressions related to probability of error, and resolution will be provided. The effect of noise in every mode will be included as well as loss. The system will provide the basic design for an imaging/detection system functioning at optical or infrared frequencies that offers better than classical angular and range resolution. Optimization for enhanced resolution will be included. The signal-to-noise ratio will be increased by a factor equal to the number of modes employed during the hyperentanglement process. Likewise, the measurement time can be reduced by the same factor. The hyperentanglement generator will typically make use of entanglement in polarization, energy-time, orbital angular momentum and so on. Mathematical results will be provided describing the system's performance as a function of loss mechanisms and noise.

  15. A novel method for the evaluation of polarization and hemisphere coverage of HF radio noise measurement antennas

    NARCIS (Netherlands)

    Witvliet, Ben A.; van Maanen, Erik; Bentum, Mark J.; Slump, Cornelis H.; Schiphorst, Roel

    2015-01-01

    In HF (3-30 MHz) communications the ambient electromagnetic background noise or 'radio noise' generally is the limiting factor in reception. Radio noise measurements are needed for spectrum pollution control and to provide reference levels for radio system design. This article discusses the

  16. Rényi entropy measure of noise-aided information transmission in a binary channel.

    Science.gov (United States)

    Chapeau-Blondeau, François; Rousseau, David; Delahaies, Agnès

    2010-05-01

    This paper analyzes a binary channel by means of information measures based on the Rényi entropy. The analysis extends, and contains as a special case, the classic reference model of binary information transmission based on the Shannon entropy measure. The extended model is used to investigate further possibilities and properties of stochastic resonance or noise-aided information transmission. The results demonstrate that stochastic resonance occurs in the information channel and is registered by the Rényi entropy measures at any finite order, including the Shannon order. Furthermore, in definite conditions, when seeking the Rényi information measures that best exploit stochastic resonance, then nontrivial orders differing from the Shannon case usually emerge. In this way, through binary information transmission, stochastic resonance identifies optimal Rényi measures of information differing from the classic Shannon measure. A confrontation of the quantitative information measures with visual perception is also proposed in an experiment of noise-aided binary image transmission.

  17. Noise resistance applied to the study of zinc rich paints; Aplicacion de la resistencia de ruido al estudio de pinturas ricas en zinc

    Energy Technology Data Exchange (ETDEWEB)

    Espada Recarey, L.; Sanchez Bermudez, A.; Urrejola Madrinan, S.; Bouzada Alvela, F. [Universidad de Vigo (Spain)

    2001-07-01

    Electrochemical Noise has been one of the more useful analysis methods to the study the corrosion processes due to the fact that it is simple and cheap. The objective of this work is to check the efficiency of this technique when it is applied to the study of Rich Zinc Paints and specifically the Noise Resistance parameter which is very efficiency to study metal-electrolyte systems. Then this technique was applied to Rich Zinc Paints systems of which we have already information by means of electrochemical impedance spectroscopy. The outcomes of this paper show the efficiency of applying Noise Resistance technique to explain the behavior of this kind of systems. (Author) 18 refs.

  18. Robust cubature Kalman filter for GNSS/INS with missing observations and colored measurement noise.

    Science.gov (United States)

    Cui, Bingbo; Chen, Xiyuan; Tang, Xihua; Huang, Haoqian; Liu, Xiao

    2018-01-01

    In order to improve the accuracy of GNSS/INS working in GNSS-denied environment, a robust cubature Kalman filter (RCKF) is developed by considering colored measurement noise and missing observations. First, an improved cubature Kalman filter (CKF) is derived by considering colored measurement noise, where the time-differencing approach is applied to yield new observations. Then, after analyzing the disadvantages of existing methods, the measurement augment in processing colored noise is translated into processing the uncertainties of CKF, and new sigma point update framework is utilized to account for the bounded model uncertainties. By reusing the diffused sigma points and approximation residual in the prediction stage of CKF, the RCKF is developed and its error performance is analyzed theoretically. Results of numerical experiment and field test reveal that RCKF is more robust than CKF and extended Kalman filter (EKF), and compared with EKF, the heading error of land vehicle is reduced by about 72.4%. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Acoustic noise measurements on a wind turbine performed in the frame of the NIWT round robin

    International Nuclear Information System (INIS)

    Van der Borg, N.J.C.M.; Vink, P.W.

    1996-11-01

    A round robin acoustic measurement campaign has been performed by five project partners using one and the same wind turbine (WT). The measurement procedure for the round robin exercise was agreed to be in compliance with the IEA-recommended practices on WT-noise emission measurements and the measured characteristics were agreed to be the apparent sound power level and the tonality, both measured at the reference measurement position. The measurements performed by ECN resulted in an A-weighted sound power level of the TACKE TW500/37 wind turbine in Hooksiel, Germany, of 95.8 dB(A) at a wind speed of 5.5 m/s at reference conditions. The tonality assessment of the sound pressure at 50 m down wind of the turbine resulted in a difference between the maximum tone level and the masking noise level of 2.4 dB. This characterizes the noise as 'prominent'. 2 refs

  20. Three dimensional electrochemical system for neurobiological studies

    DEFF Research Database (Denmark)

    Vazquez, Patricia; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    In this work we report a novel three dimensional electrode array for electrochemical measurements in neuronal studies. The main advantage of working with these out-of-plane structures is the enhanced sensitivity of the system in terms of measuring electrochemical changes in the environment...

  1. Analysis and evaluation of soundscapes in public parks through interviews and measurement of noise.

    Science.gov (United States)

    Szeremeta, Bani; Zannin, Paulo Henrique Trombetta

    2009-12-01

    The purpose of this work was to investigate the sound environment of public parks using a soundscape study model that analyzes not only noise but also all the types of sound of a given area, as well as other environmental factors. To this end, acoustic measurements were made in the parks under study and interviews were held with their frequent visitors. Noise measurements were conducted in 55 points, and a total of 335 people were interviewed in the 4 parks studied. The parks selected for this study are located in areas very close to streets with intense vehicle flow, raising the hypothesis that this proximity impairs the acoustic comfort of their visitors. The findings confirm the strong influence of traffic noise on the soundscapes of the parks. Noise measurements showed that in all parks, between 50 and 100% of the points evaluated displayed sound levels above 55dB(A), the level established by Curitiba's Municipal Law 10625 as the limit permitted for green areas during daytime. Other conditions in the parks' environments were also identified, which interfere jointly in the soundscape and in its perception, such as spatial factors of each park, the urban setting of its surroundings, and the sounds originating inside the parks.

  2. The use of ground reflecting boards in measuring wind turbine noise

    International Nuclear Information System (INIS)

    Henderson, A.R.; Mackinnon, A.; Benson, I.M.

    1992-01-01

    This paper gives an account of an experimental programme to assess the ground microphone measurement technique which can potentially increase the accuracy, reliability and confidence in wind turbine noise emission measurements. It shows that a 1 m diameter circular board can achieve acceptable accuracy and, since it is significantly more practical to use, could readily be adopted for international standards. (author)

  3. The Discrete Wavelet Transform and Its Application for Noise Removal in Localized Corrosion Measurements

    Directory of Open Access Journals (Sweden)

    Rogelio Ramos

    2017-01-01

    Full Text Available The present work discusses the problem of induced external electrical noise as well as its removal from the electrical potential obtained from Scanning Vibrating Electrode Technique (SVET in the pitting corrosion process of aluminum alloy A96061 in 3.5% NaCl. An accessible and efficient solution of this problem is presented with the use of virtual instrumentation (VI, embedded systems, and the discrete wavelet transform (DWT. The DWT is a computational algorithm for digital processing that allows obtaining electrical noise with Signal to Noise Ratio (SNR superior to those obtained with Lock-In Amplifier equipment. The results show that DWT and the threshold method are efficient and powerful alternatives to carry out electrical measurements of potential signals from localized corrosion processes measured by SVET.

  4. Aerodynamic noise characterization of a full-scale wind turbine through high-frequency surface pressure measurements

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Bak, Christian

    2015-01-01

    The aim of this work is to investigate and characterize the high-frequency surface pressure fluctuations on a full-scale wind turbine blade and in particular the influence of the atmospheric turbulence. As these fluctuations are highly correlated to the sources of both turbulent inflow noise...... and trailing edge noise, recognized to be the two main sources of noise from wind turbines, this work contributes to a more detailed insight into noise from wind turbines. The study comprises analysis and interpretation of measurement data that were acquired during an experimental campaign involving a 2 MW...... wind turbine with a 80 m diameter rotor as well as measurements of an airfoil section tested in a wind tunnel. The turbine was extensively equipped in order to monitor the local inflow onto the rotating blades. Further a section of the 38 m long blade was instrumented with 50 microphones flush...

  5. Correlation between electrochemical impedance measurements and corrosion rate of magnesium investigated by real-time hydrogen measurement and optical imaging

    OpenAIRE

    Curioni, M.; Scenini, F.; Monetta, T.; Bellucci, F.

    2015-01-01

    The corrosion behaviour of magnesium in chloride-containing aqueous environment was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) performed simultaneously with real-time hydrogen evolution measurements and optical imaging of the corroding surface. The potentiodynamic investigation revealed substantial deviations from linearity in close proximity of the corrosion potential. In particular, differences in the slope of the current/potential curves w...

  6. Electrochemical Noise Sensors for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines. Final Report for the Period July 2001-October 2002

    Energy Technology Data Exchange (ETDEWEB)

    Bullard, Sophie J.; Covino, Jr., Bernard S.; Russell, James H.; Holcomb, Gordon R.; Cramer, Stephen D.; Ziomek-Moroz, Margaret

    2002-12-01

    The U.S. Department of Energy, National Energy Technology Laboratory funded a Natural Gas Infrastructure Reliability program directed at increasing and enhancing research and development activities in topics such as remote leak detection, pipe inspection, and repair technologies and materials. The Albany Research Center (ARC), U.S. Department of Energy was funded to study the use of electrochemical noise sensors for detection of localized and general corrosion of natural gas transmission pipelines. As part of this, ARC entered into a collaborative effort with the corrosion sensor industry to demonstrate the capabilities of commercially available remote corrosion sensors for use with the Nation's Gas Transmission Pipeline Infrastructure needs. The goal of the research was to develop an emerging corrosion sensor technology into a monitor for the type and degree of corrosion occurring at key locations in gas transmission pipelines.

  7. Measured and calculated noise reduction of rail dampers and absorption plates on a high speed slab track

    NARCIS (Netherlands)

    Dittrich, M.G.; Graafland, F.; Eisses, A.R.; Nijhof, M.J.J.

    2015-01-01

    Rail dampers and sound absorbing plates have been tested on a high speed railway slab track in a walled cutting at a noise sensitive location. Their noise reduction has been determined from pass-by measurements during service and predicted using BEM calculations. The cutting depth, noise barrier

  8. Noise pollution resources compendium

    Science.gov (United States)

    1973-01-01

    Abstracts of reports concerning noise pollution are presented. The abstracts are grouped in the following areas of activity: (1) sources of noise, (2) noise detection and measurement, (3) noise abatement and control, (4) physical effects of noise and (5) social effects of noise.

  9. Subassembly faults diagnostic of an LMFBR type reactor by the measurement of temperature noise

    International Nuclear Information System (INIS)

    Kokorev, B.V.; Palkin, I.I.; Turchin, N.M.; Pallagi, D.; Horanyi, S.

    1979-09-01

    The subassembly faults detection possibility by temperature noise analysis of an LMFBR is described. The paper contains the results of diagnostical examinations obtained on electrically heated NaK test rigs. On the basis of these results the measurement of temperature noise RMS value seems to be a practicable method to detect local blockages in an early phase. (author)

  10. Measurements of Low Frequency Noise of Infrared Photo-Detectors with Transimpedance Detection System

    Directory of Open Access Journals (Sweden)

    Ciura Łukasz

    2014-08-01

    Full Text Available The paper presents the method and results of low-frequency noise measurements of modern mid-wavelength infrared photodetectors. A type-II InAs/GaSb superlattice based detector with nBn barrier architecture is compared with a high operating temperature (HOT heterojunction HgCdTe detector. All experiments were made in the range 1 Hz - 10 kHz at various temperatures by using a transimpedance detection system, which is examined in detail. The power spectral density of the nBn’s dark current noise includes Lorentzians with different time constants while the HgCdTe photodiode has more uniform 1/f - shaped spectra. For small bias, the low-frequency noise power spectra of both devices were found to scale linearly with bias voltage squared and were connected with the fluctuations of the leakage resistance. Leakage resistance noise defines the lower noise limit of a photodetector. Other dark current components give raise to the increase of low-frequency noise above this limit. For the same voltage biasing devices, the absolute noise power densities at 1 Hz in nBn are 1 to 2 orders of magnitude lower than in a MCT HgCdTe detector. In spite of this, low-frequency performance of the HgCdTe detector at ~ 230K is still better than that of InAs/GaSb superlattice nBn detector.

  11. Evaluation of noise pollution in oil extracting region of Lavan and the effect of noise enclosure on noise abatement

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2007-09-01

    Full Text Available Background and aims   Overexposure to industrial noise pollution induce hearing loss workers. Occupational hearing loss may cause interference whit oral communication, so it may  increase the risk of occupational accidents in workplace as well as affects whit social activities.  This study was conducted on Lavan Island, are of oil extracting regions in the south of Iran. The  object of this study was to evaluate noise pollution and determining the effect of noise enclosure  on noise abatement.   Methods   The noise sources were recognized and noise pressure level was measured by CEL- 440. Noise dose of the exposed workers in high level noise area were measured by CEL 272.   Results   Major noise sources were gas turbines, diesel generators, compressors, fans and gas containing pips, noise contour map revealers that noise level were higher than the recommended national exposure limit. The results of workers noise dose show that their noise exposure were  higher than the recommended value, (p<0.001. Finally, by using the results of noise frequency  analysis of different noise sources, the noise pressure level of each sources was determined in   terms of enclosing them.   Conclusion   By enclosing the noise sources, noise pressure levels can be lowered douse to  acceptable levels but limitation of applying enclosure should be regarded.  

  12. Noise Exposure of Teachers in Nursery Schools-Evaluation of Measures for Noise Reduction When Dropping DUPLO Toy Bricks into Storage Cases by Sound Analyses.

    Science.gov (United States)

    Gebauer, Konstanze; Scharf, Thomas; Baumann, Uwe; Groneberg, David A; Bundschuh, Matthias

    2016-07-04

    Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. The lowest LAFmax was measured in cases consisting of "metal grid" (90.71 dB) or of a woven willow "basket" (91.61 dB), whereas a case of "aluminium" (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs "metal grid" and "basket". The insertion of PU-foam achieved the most significant attenuation of LAFmax (-13.88 dB) and, in the frequency analyses, the best sound damping. The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven "basket" with an insert of PU-foam.

  13. Active self-testing noise measurement sensors for large-scale environmental sensor networks.

    Science.gov (United States)

    Domínguez, Federico; Cuong, Nguyen The; Reinoso, Felipe; Touhafi, Abdellah; Steenhaut, Kris

    2013-12-13

    Large-scale noise pollution sensor networks consist of hundreds of spatially distributed microphones that measure environmental noise. These networks provide historical and real-time environmental data to citizens and decision makers and are therefore a key technology to steer environmental policy. However, the high cost of certified environmental microphone sensors render large-scale environmental networks prohibitively expensive. Several environmental network projects have started using off-the-shelf low-cost microphone sensors to reduce their costs, but these sensors have higher failure rates and produce lower quality data. To offset this disadvantage, we developed a low-cost noise sensor that actively checks its condition and indirectly the integrity of the data it produces. The main design concept is to embed a 13 mm speaker in the noise sensor casing and, by regularly scheduling a frequency sweep, estimate the evolution of the microphone's frequency response over time. This paper presents our noise sensor's hardware and software design together with the results of a test deployment in a large-scale environmental network in Belgium. Our middle-range-value sensor (around €50) effectively detected all experienced malfunctions, in laboratory tests and outdoor deployments, with a few false positives. Future improvements could further lower the cost of our sensor below €10.

  14. Electrochemical Processes

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers

    1997-01-01

    The notes describe in detail primary and secondary galvanic cells, fuel cells, electrochemical synthesis and electroplating processes, corrosion: measurments, inhibitors, cathodic and anodic protection, details of metal dissolution reactions, Pourbaix diagrams and purification of waste water from...

  15. Time response measurements of pressure sensors using pink noise technique

    International Nuclear Information System (INIS)

    Pereira, Iraci Martinez; Santos, Roberto Carlos dos

    2009-01-01

    This work presents an experimental setup for Pink Noise method application on pressure transmitters' response times. The Pink Noise method consists on injecting artificial pressure noise into the pressure transmitter. The artificial pressure noise is generated using a current-to-pressure (I-to-P) converter, which is driven by a random noise signal generator. The output pressure transmitter noise is then analyzed using conventional Noise Analysis Technique. Noise signals may be interpreted using spectral techniques or empirical time series models. The frequency domain method consists of evaluating the Power Spectral Density (PSD) function. The information needed for time constant estimation can be obtained by fitting an all-pole transfer function to this power spectral density. (author)

  16. Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

    Science.gov (United States)

    Spalt, Taylor B.; Brooks, Thomas F.; Fuller, Christopher R.

    2012-01-01

    Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

  17. High Resolution Viscosity Measurement by Thermal Noise Detection

    Directory of Open Access Journals (Sweden)

    Felipe Aguilar Sandoval

    2015-11-01

    Full Text Available An interferometric method is implemented in order to accurately assess the thermal fluctuations of a micro-cantilever sensor in liquid environments. The power spectrum density (PSD of thermal fluctuations together with Sader’s model of the cantilever allow for the indirect measurement of the liquid viscosity with good accuracy. The good quality of the deflection signal and the characteristic low noise of the instrument allow for the detection and corrections of drawbacks due to both the cantilever shape irregularities and the uncertainties on the position of the laser spot at the fluctuating end of the cantilever. Variation of viscosity below 0.03 mPa·s was detected with the alternative to achieve measurements with a volume as low as 50 µL.

  18. Robustness of SOC Estimation Algorithms for EV Lithium-Ion Batteries against Modeling Errors and Measurement Noise

    Directory of Open Access Journals (Sweden)

    Xue Li

    2015-01-01

    Full Text Available State of charge (SOC is one of the most important parameters in battery management system (BMS. There are numerous algorithms for SOC estimation, mostly of model-based observer/filter types such as Kalman filters, closed-loop observers, and robust observers. Modeling errors and measurement noises have critical impact on accuracy of SOC estimation in these algorithms. This paper is a comparative study of robustness of SOC estimation algorithms against modeling errors and measurement noises. By using a typical battery platform for vehicle applications with sensor noise and battery aging characterization, three popular and representative SOC estimation methods (extended Kalman filter, PI-controlled observer, and H∞ observer are compared on such robustness. The simulation and experimental results demonstrate that deterioration of SOC estimation accuracy under modeling errors resulted from aging and larger measurement noise, which is quantitatively characterized. The findings of this paper provide useful information on the following aspects: (1 how SOC estimation accuracy depends on modeling reliability and voltage measurement accuracy; (2 pros and cons of typical SOC estimators in their robustness and reliability; (3 guidelines for requirements on battery system identification and sensor selections.

  19. Electrochemical reduction of NOx

    DEFF Research Database (Denmark)

    Traulsen, Marie Lund

    NO and NO2 (collectively referred to as NOx) are air pollutants, and the largest single contributor to NOx pollution is automotive exhaust. This study investigates electrochemical deNOx, a technology which aims to remove NOx from automotive diesel exhaust by electrochemical reduction of NOx to N2...... and O2. The focus in this study is on improving the activity and selectivity of solid oxide electrodes for electrochemical deNOx by addition of NOx storage compounds to the electrodes. Two different composite electrodes, La0.85Sr0.15MnO3-δ-Ce0.9Gd0.1O1.95 (LSM15-CGO10) and La0.85Sr0.15FeO3-δ-Ce0.9Gd0.1O......1.95 (LSF15-CGO10), have been investigated in combination with three different NOx storage compounds: BaO, K2O and MnOx. The main focus in the investigation has been on conversion measurements and electrochemical characterization, the latter by means of electrochemical impedance spectroscopy...

  20. Possibilities and limitations of ionic liquids in electrochemical and electroanalytical measurements (a review)

    OpenAIRE

    Weidlich, Tomáš; Stočes, Matěj; Švancara, Ivan

    2010-01-01

    A review (with 155 refs.) concerning the current achievements and typical trends in the chemistry of (room temperature) ionic liquids, (RT)ILs, with particular emphasis on their applicability in electrochemical and electroanalytical measurements. The latter is documented on a rapid progress of ionic liquid-modified carbon paste electrodes (IL-CPEs), the so-called carbon ionic liquid electrodes (CILEs), and related configurations in the last half-decade, within the period of 200...

  1. Measurement and analysis of the neutron noise of the pool research reactor at IPEN

    International Nuclear Information System (INIS)

    Simoes, Graciete Pedro

    1979-01-01

    Variations in the neutron density or power of a nuclear reactor (the neutron noise) operating at nominally constant power are generally random and can only be described in terms of statistical parameters. Random variations in the power of a power reactor are produced by one or more driving functions. In this work the neutron noise of the pool reactor IEAR-1 (2 MW nominal power) has been studied using two compensated ionization chambers ( Westinghouse VJL6377) and related to three possible-driving functions, namely vibration of the control bar and reactor support bridge and the temperature of the water entering the core. The CIC detectors were located in rigid tubes in turn positively located in the reactor lattice plate. Conventional accelerometers were used. Temperature measurements were made with a NiCr/Ni thermocouple (wire diam ∼ 0.2mm) located 10 mm above the top of a fuel element. Although the correlation between the measured neutron signals was high ( > 0,4) for frequencies in the range 0 to 10 Hz no resonances were identified in the neutron noise. A significant correlation (> 0,4) between the control bar acceleration and the neutron flux was obtained in the frequency range 0 to 10 Hz. The measured correlation between the neutron noise and both the bridge vibration and the reactor water inlet temperature was insignificant. (author)

  2. Proceedings of the 2009 spring noise conference : noise awareness : supporting sound partnerships

    International Nuclear Information System (INIS)

    2009-01-01

    This conference provided a forum for industry, government, public, academics and acoustical professionals to discuss innovations in environmental and occupational noise identification, measurement, regulation and control. In addition to raising awareness about expanding noise issues, the conference objectives were to promote responsible industrial development and to identify strategies for reducing workplace noise exposure. The papers focused on research, developments and case studies and highlighted current issues and advancements in technology and software. Speakers from around the world discussed topics ranging from occupational noise issues to low frequency. The 8 sessions were entitled: (1) plenary session, (2) architecture, community planning and public health: effects of noise and noise control, (3) modeling, measurement and technology; (4) noise awareness and education: public, occupational and industrial, (5) regulations and economics: bylaws, legislation and the economics of noise control; (6) student papers, (7) vibration, industrial noise, transportation noise and occupational noise control, and (8) lunch speakers. The conference featured 46 presentations, of which 19 have been catalogued separately for inclusion in this database. refs., tabs., figs.

  3. Measuring and Assessment the Noise Level in Different Regions in Baghdad City And Compare it with The Allowable Levels

    Directory of Open Access Journals (Sweden)

    Ibtihaj Abdulwahhab Abdulrazzak

    2017-05-01

    Full Text Available This study includes measurement of the noise level of four regions in the city of Baghdad (industrial region, commercial region, residential region and quiet region and compare the value of noise in each region with the World Health Organization (WHO allowable limits, and the effect of noise on human health was explained. The "sound level meter (SLM" instrument measuring the noise value in the four regions, three measurement per month through one year was recorded (one measurement every ten days from 1/1/2015 to 30/12/2015. The noise level of the industrial region (75dB compared with the World Health Organization level allowable limit (65dB, while the commercial region (76.28dB versus (55dB and the residential region (74.94dB versus (50dB and the quiet region was (62.36dB versus (40dB of the (WHO allowable limit.

  4. The Assessment of Noise Exposure and Noise Annoyance at a Petrochemical Company

    Directory of Open Access Journals (Sweden)

    S. Farhang Dehghan

    2013-12-01

    .Conclusion: Based on the obtained results of investigating the noise level (objective exposure as well as the noise annoyance (subjective exposure at the studied company, it is necessary to adopt the management –technical noise reduction measures at manufacturing sectors as the personal noise exposure and environmental noise exposure and also noise personal exposure of administrative staff can be decreased.

  5. Noise immission from wind turbines

    International Nuclear Information System (INIS)

    1999-01-01

    The project has dealt with practical ways to reduce the influence of background noise caused by wind acting on the measuring microphones. The uncertainty of measured noise emission (source strength) has been investigated. The main activity was a Round Robin Test involving measurements by five laboratories at the same wind turbine. Each laboratory brought its own instrumentation and performed the measurements and analyses according to their interpretation. The tonality of wind turbine noise is an essential component of the noise impact on the environment. In the present project the uncertainty in the newest existing methods for assessing tonality was investigated. The project included noise propagation measurements in different weather conditions around wind turbines situated in different types of terrain. The results were used to validate a noise propagation model developed in the project. Finally, the project also included a study with listeners evaluating recordings of wind turbine noise. The results are intended as guidance for wind turbine manufacturers in identifying the aspects of wind turbine noise most important to annoyance. (author)

  6. Dynamical analysis of electrochemical wall shear rate measurements

    NARCIS (Netherlands)

    Steenhoven, van A.A.; Beucken, van den F.J.H.M.

    1991-01-01

    The performance of a circular electrochemical wall shear rate probe under unsteady flow conditions is analysed through a combined ezxperimental, numerical and analytical approach. The experiments are performed with a ferri- and ferrocyanide redox couple and compared to finite element analysis of the

  7. Noise Exposure of Teachers in Nursery Schools—Evaluation of Measures for Noise Reduction When Dropping DUPLO Toy Bricks into Storage Cases by Sound Analyses

    Directory of Open Access Journals (Sweden)

    Konstanze Gebauer

    2016-07-01

    Full Text Available Background: Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. Methods: This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam were investigated. Results: The lowest LAFmax was measured in cases consisting of “metal grid” (90.71 dB or of a woven willow “basket” (91.61 dB, whereas a case of “aluminium” (103.34 dB generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs “metal grid” and “basket”. The insertion of PU-foam achieved the most significant attenuation of LAFmax (−13.88 dB and, in the frequency analyses, the best sound damping. Conclusion: The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven “basket” with an insert of PU-foam.

  8. Electrochemical impedance spectroscopy of oxidized porous silicon

    Energy Technology Data Exchange (ETDEWEB)

    Mula, Guido, E-mail: guido.mula@unica.it [Dipartimento di Fisica, Università degli Studi di Cagliari, Cittadella Universitaria di Monserrato, S.P. 8 km 0.700, 09042 Cagliari (Italy); Tiddia, Maria V. [Dipartimento di Fisica, Università degli Studi di Cagliari, Cittadella Universitaria di Monserrato, S.P. 8 km 0.700, 09042 Cagliari (Italy); Ruffilli, Roberta [Nanochemistry, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genova (Italy); Falqui, Andrea [Nanochemistry, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genova (Italy); Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Cagliari, Cittadella Universitaria di Monserrato, S.P. 8 km 0.700, 09042 Cagliari (Italy); Palmas, Simonetta; Mascia, Michele [Dipartimento di Ingegneria Meccanica Chimica e dei Materiali, Università degli Studi di Cagliari, Piazza d' Armi, 09126 Cagliari (Italy)

    2014-04-01

    We present a study of the electrochemical oxidation process of porous silicon. We analyze the effect of the layer thickness (1.25–22 μm) and of the applied current density (1.1–11.1 mA/cm{sup 2}, values calculated with reference to the external samples surface) on the oxidation process by comparing the galvanostatic electrochemical impedance spectroscopy (EIS) measurements and the optical specular reflectivity of the samples. The results of EIS were interpreted using an equivalent circuit to separate the contribution of different sample parts. A different behavior of the electrochemical oxidation process has been found for thin and thick samples: whereas for thin samples the oxidation process is univocally related to current density and thickness, for thicker samples this is no more true. Measurements by Energy Dispersive Spectroscopy using a Scanning Electron Microscopy confirmed that the inhomogeneity of the electrochemical oxidation process is increased by higher thicknesses and higher currents. A possible explanation is proposed to justify the different behavior of thin and thick samples during the electrochemical process. - Highlights: • A multidisciplinary approach on porous Si electrochemical oxidation is proposed. • Electrochemical, optical, and structural characterizations are used. • Layer thickness and oxidation current effects are shown. • An explanation of the observed behavior is proposed.

  9. Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement.

    Science.gov (United States)

    Dwivedi, Prashant Povel; Choi, Hee Joo; Kim, Byoung Joo; Cha, Myoungsik

    2013-12-16

    Random duty-cycle errors (RDE) in ferroelectric quasi-phase-matching (QPM) devices not only affect the frequency conversion efficiency, but also generate non-phase-matched parasitic noise that can be detrimental to some applications. We demonstrate an accurate but simple method for measuring the RDE in periodically poled lithium niobate. Due to the equivalence between the undepleted harmonic generation spectrum and the diffraction pattern from the QPM grating, we employed linear diffraction measurement which is much simpler than tunable harmonic generation experiments [J. S. Pelc, et al., Opt. Lett.36, 864-866 (2011)]. As a result, we could relate the RDE for the QPM device to the relative noise intensity between the diffraction orders.

  10. Electrochemical Analysis of Neurotransmitters

    Science.gov (United States)

    Bucher, Elizabeth S.; Wightman, R. Mark

    2015-07-01

    Chemical signaling through the release of neurotransmitters into the extracellular space is the primary means of communication between neurons. More than four decades ago, Ralph Adams and his colleagues realized the utility of electrochemical methods for the study of easily oxidizable neurotransmitters, such as dopamine, norepinephrine, and serotonin and their metabolites. Today, electrochemical techniques are frequently coupled to microelectrodes to enable spatially resolved recordings of rapid neurotransmitter dynamics in a variety of biological preparations spanning from single cells to the intact brain of behaving animals. In this review, we provide a basic overview of the principles underlying constant-potential amperometry and fast-scan cyclic voltammetry, the most commonly employed electrochemical techniques, and the general application of these methods to the study of neurotransmission. We thereafter discuss several recent developments in sensor design and experimental methodology that are challenging the current limitations defining the application of electrochemical methods to neurotransmitter measurements.

  11. Hydroacoustic measurements of the radiated noise from Wave Energy Converters in the Lysekil project and project WESA

    OpenAIRE

    Haikonen, Kalle; Sundberg, Jan; Leijon, Mats

    2013-01-01

    Field measurements of the hydroacoustic noise from Wave Energy Converters (WECs) in the Lysekil project at Uppsala University and the Project WESA (joint effort between Uppsala University (Lead Partner), Ålands Teknikkluster r.f. and University of Turku) are presented. Anthropogenic noise is increasing in the oceans world wide and wave energy conversion may contribute to this noise, but to what extent? The main objective in this study is to examine the noise from full scale operating WECs in ...

  12. An Alternative Corrosion Resistance Test Method for Solar Cells and Interconnection Materials Limiting the Number of Long-lasting and Expensive Damp-Heat Climate Chamber Tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Gouwen, R.J.; Veldman, D.; Bende, E.E.; Eerenstein, W. [ECN Solar Energy, Petten (Netherlands)

    2013-06-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. We present an alternative test method: electrochemical noise (EcN) measurements. Data acquisition times vary between minutes for direct exposure to several tens of hours for encapsulated samples. EcN measurements are presented for several solar cell concepts and different environments. We have found that the degradation in damp-heat testing is proportional to the electrochemical noise signal. In conclusion, the electrochemical noise measurements are a fast, versatile tool to test the corrosion resistance of solar cells, which can be tested for different environments including encapsulation.

  13. Noise power spectrum of the fixed pattern noise in digital radiography detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik, E-mail: dskim@hufs.ac.kr [Department of Electronics Engineering, Hankuk University of Foreign Studies, Gyeonggi-do 449-791 (Korea, Republic of); Kim, Eun [R& D Center, DRTECH Co., Gyeonggi-do 13558 (Korea, Republic of)

    2016-06-15

    Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain

  14. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  15. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  16. Yesterday's noise - today's signal

    International Nuclear Information System (INIS)

    Serdula, K.J.

    1978-01-01

    Plant performance can be improved by noise analysis. This paper describes noise characteristics, imposed noise and response functions, a case history of cost benefits derived from application of noise analysis techniques, areas for application of noise analysis techniques with special reference to the Gentilly-1 nuclear generating station, and the validity of noise measurement results. (E.C.B.)

  17. An electrochemical sensor device for measuring blood ammonia at the point of care.

    Science.gov (United States)

    Brannelly, N T; Killard, A J

    2017-05-15

    The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r 2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, pair (n =12) and could be stored in desiccant for at least five months. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Retrospective Correction of Physiological Noise in DTI Using an Extended Tensor Model and Peripheral Measurements

    Science.gov (United States)

    Mohammadi, Siawoosh; Hutton, Chloe; Nagy, Zoltan; Josephs, Oliver; Weiskopf, Nikolaus

    2013-01-01

    Diffusion tensor imaging is widely used in research and clinical applications, but this modality is highly sensitive to artefacts. We developed an easy-to-implement extension of the original diffusion tensor model to account for physiological noise in diffusion tensor imaging using measures of peripheral physiology (pulse and respiration), the so-called extended tensor model. Within the framework of the extended tensor model two types of regressors, which respectively modeled small (linear) and strong (nonlinear) variations in the diffusion signal, were derived from peripheral measures. We tested the performance of four extended tensor models with different physiological noise regressors on nongated and gated diffusion tensor imaging data, and compared it to an established data-driven robust fitting method. In the brainstem and cerebellum the extended tensor models reduced the noise in the tensor-fit by up to 23% in accordance with previous studies on physiological noise. The extended tensor model addresses both large-amplitude outliers and small-amplitude signal-changes. The framework of the extended tensor model also facilitates further investigation into physiological noise in diffusion tensor imaging. The proposed extended tensor model can be readily combined with other artefact correction methods such as robust fitting and eddy current correction. PMID:22936599

  19. Implementation of New Reactivity Measurement System and New Reactor Noise Analysis Equipment in a VVER-440 Nuclear Power Plant

    Science.gov (United States)

    Vegh, János; Kiss, Sándor; Lipcsei, Sándor; Horvath, Csaba; Pos, István; Kiss, Gábor

    2010-10-01

    The paper deals with two recently developed, high-precision nuclear measurement systems installed at the VVER-440 units of the Hungarian Paks NPP. Both developments were motivated by the reactor power increase to 108%, and by the planned plant service time extension. The first part describes the RMR start-up reactivity measurement system with advanced services. High-precision picoampere meters were installed at each reactor unit and measured ionization chamber current signals are handled by a portable computer providing data acquisition and online reactivity calculation service. Detailed offline evaluation and analysis of reactor start-up measurements can be performed on the portable unit, too. The second part of the paper describes a new reactor noise diagnostics system using state-of-the-art data acquisition hardware and signal processing methods. Details of the new reactor noise measurement evaluation software are also outlined. Noise diagnostics at Paks NPP is a standard tool for core anomaly detection and for long-term noise trend monitoring. Regular application of these systems is illustrated by real plant data, e.g., results of standard reactivity measurements during a reactor startup session are given. Noise applications are also illustrated by real plant measurements; results of core anomaly detection are presented.

  20. An Adaptive Low-Cost INS/GNSS Tightly-Coupled Integration Architecture Based on Redundant Measurement Noise Covariance Estimation.

    Science.gov (United States)

    Li, Zheng; Zhang, Hai; Zhou, Qifan; Che, Huan

    2017-09-05

    The main objective of the introduced study is to design an adaptive Inertial Navigation System/Global Navigation Satellite System (INS/GNSS) tightly-coupled integration system that can provide more reliable navigation solutions by making full use of an adaptive Kalman filter (AKF) and satellite selection algorithm. To achieve this goal, we develop a novel redundant measurement noise covariance estimation (RMNCE) theorem, which adaptively estimates measurement noise properties by analyzing the difference sequences of system measurements. The proposed RMNCE approach is then applied to design both a modified weighted satellite selection algorithm and a type of adaptive unscented Kalman filter (UKF) to improve the performance of the tightly-coupled integration system. In addition, an adaptive measurement noise covariance expanding algorithm is developed to mitigate outliers when facing heavy multipath and other harsh situations. Both semi-physical simulation and field experiments were conducted to evaluate the performance of the proposed architecture and were compared with state-of-the-art algorithms. The results validate that the RMNCE provides a significant improvement in the measurement noise covariance estimation and the proposed architecture can improve the accuracy and reliability of the INS/GNSS tightly-coupled systems. The proposed architecture can effectively limit positioning errors under conditions of poor GNSS measurement quality and outperforms all the compared schemes.

  1. Entropy as a measure of the noise extent in a two-level quantum feedback controlled system

    Institute of Scientific and Technical Information of China (English)

    Wang Tao-Bo; Fang Mao-Fa; Hu Yao-Hua

    2007-01-01

    By introducing the von Neumann entropy as a measure of the extent of noise, this paper discusses the entropy evolution in a two-level quantum feedback controlled system. The results show that the feedback control can induce the reduction of the degree of noise, and different control schemes exhibit different noise controlling ability, the extent of the reduction also related with the position of the target state on the Bloch sphere. It is shown that the evolution of entropy can provide a real time noise observation and a systematic guideline to make reasonable choice of control strategy.

  2. Shot-noise-limited optical Faraday polarimetry with enhanced laser noise cancelling

    International Nuclear Information System (INIS)

    Li, Jiaming; Luo, Le; Carvell, Jeff; Cheng, Ruihua; Lai, Tianshu; Wang, Zixin

    2014-01-01

    We present a shot-noise-limited measurement of optical Faraday rotations with sub-ten-nanoradian angular sensitivity. This extremely high sensitivity is achieved by using electronic laser noise cancelling and phase sensitive detection. Specially, an electronic laser noise canceller with a common mode rejection ratio of over 100 dB was designed and built for enhanced laser noise cancelling. By measuring the Faraday rotation of ambient air, we demonstrate an angular sensitivity of up to 9.0×10 −9  rad/√(Hz), which is limited only by the shot-noise of the photocurrent of the detector. To date, this is the highest angular sensitivity ever reported for Faraday polarimeters in the absence of cavity enhancement. The measured Verdet constant of ambient air, 1.93(3)×10 −9 rad/(G cm) at 633 nm wavelength, agrees extremely well with the earlier experiments using high finesse optical cavities. Further, we demonstrate the applications of this sensitive technique in materials science by measuring the Faraday effect of an ultrathin iron film

  3. Noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization

    International Nuclear Information System (INIS)

    Braginsky, Vladimir B.; Gorodetsky, Mikhail L.; Khalili, Farid Ya.; Vyatchanin, Sergey P.; Matsko, Andrey B.; Thorne, Kip S.

    2003-01-01

    It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output [the photon number flux N(t) entering the final photodetector] commutes with itself at different times in the Heisenberg picture, [N(t),N(t ' )]=0 and thus can be regarded as classical. (ii) This number flux is linear to high accuracy in the test-mass initial position and momentum operators x o and p o , and those operators influence the measured photon flux N(t) in manners that can easily be removed by filtering. For example, in most interferometers x o and p o appear in N(t) only at the test masses' ∼1 Hz pendular swinging frequency and their influence is removed when the output data are high-pass filtered to get rid of noise below ∼10 Hz. The test-mass operators x o and p o contained in the unfiltered output N(t) make a nonzero contribution to the commutator [N(t),N(t ' )]. That contribution is precisely canceled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations, and get identically the same result. These conclusions are all true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that

  4. On the excess photon noise in single-beam measurements with photo-emissive and photo-conductive cells

    NARCIS (Netherlands)

    Alkemade, C.T.J.

    In this paper the so-called excess photon noise is theoretically considered with regard to noise power measurements with a single, illumined photo-emissive or photo-conductive cell. Starting from a modification of Mandel's stochastic association of the emission of photo-electrons with wave

  5. A low cost computer-controlled electrochemical measurement system for education and research

    International Nuclear Information System (INIS)

    Cottis, R.A.

    1989-01-01

    With the advent of low cost computers of significant processing power, it has become economically attractive, as well as offering practical advantages, to replace conventional electrochemical instrumentation with computer-based equipment. For example, the equipment to be described can perform all of the functions required for the measurement of a potentiodynamic polarization curve, replacing the conventional arrangement of sweep generator, potentiostat and chart recorder at a cost (based on the purchase cost of parts) which is less than that of most chart recorders alone. Additionally the use of computer control at a relatively low level provides a versatility (assuming the development of suitable software) which cannot easily be matched by conventional instruments. As a result of these considerations a simple computer-controlled electrochemical measurement system has been developed, with a primary aim being its use in teaching an MSc class in corrosion science and engineering, with additional applications in MSc and PhD research. For education reasons the design of the user interface has tried to make the internal operation of the unit as obvious as possible, and thereby minimize the tendency for students to treat the unit as a 'black box' with incomprehensible inner workings. This has resulted in a unit in which the three main components of function generator, potentiostat and recorder are presented as independent areas on the front panel, and can be configured by the user in exactly the same way as conventional instruments. (author) 11 figs

  6. A low cost computer-controlled electrochemical measurement system for education and research

    Energy Technology Data Exchange (ETDEWEB)

    Cottis, R A [Manchester Univ. (UK). Inst. of Science and Technology

    1989-01-01

    With the advent of low cost computers of significant processing power, it has become economically attractive, as well as offering practical advantages, to replace conventional electrochemical instrumentation with computer-based equipment. For example, the equipment to be described can perform all of the functions required for the measurement of a potentiodynamic polarization curve, replacing the conventional arrangement of sweep generator, potentiostat and chart recorder at a cost (based on the purchase cost of parts) which is less than that of most chart recorders alone. Additionally the use of computer control at a relatively low level provides a versatility (assuming the development of suitable software) which cannot easily be matched by conventional instruments. As a result of these considerations a simple computer-controlled electrochemical measurement system has been developed, with a primary aim being its use in teaching an MSc class in corrosion science and engineering, with additional applications in MSc and PhD research. For education reasons the design of the user interface has tried to make the internal operation of the unit as obvious as possible, and thereby minimize the tendency for students to treat the unit as a 'black box' with incomprehensible inner workings. This has resulted in a unit in which the three main components of function generator, potentiostat and recorder are presented as independent areas on the front panel, and can be configured by the user in exactly the same way as conventional instruments. (author) 11 figs.

  7. Electrochemical Detection in Stacked Paper Networks.

    Science.gov (United States)

    Liu, Xiyuan; Lillehoj, Peter B

    2015-08-01

    Paper-based electrochemical biosensors are a promising technology that enables rapid, quantitative measurements on an inexpensive platform. However, the control of liquids in paper networks is generally limited to a single sample delivery step. Here, we propose a simple method to automate the loading and delivery of liquid samples to sensing electrodes on paper networks by stacking multiple layers of paper. Using these stacked paper devices (SPDs), we demonstrate a unique strategy to fully immerse planar electrodes by aqueous liquids via capillary flow. Amperometric measurements of xanthine oxidase revealed that electrochemical sensors on four-layer SPDs generated detection signals up to 75% higher compared with those on single-layer paper devices. Furthermore, measurements could be performed with minimal user involvement and completed within 30 min. Due to its simplicity, enhanced automation, and capability for quantitative measurements, stacked paper electrochemical biosensors can be useful tools for point-of-care testing in resource-limited settings. © 2015 Society for Laboratory Automation and Screening.

  8. Retrieval of reflections from seismic background?noise measurements

    NARCIS (Netherlands)

    Draganov, D.S.; Wapenaar, K.; Mulder, W.; Singer, J.; Verdel, A.

    2007-01-01

    The retrieval of the earth's reflection response from cross?correlations of seismic noise recordings can provide valuable information, which may otherwise not be available due to limited spatial distribution of seismic sources. We cross?correlated ten hours of seismic background?noise data acquired

  9. Contribution to tyre noise measurement adapted to human ears to future optimisation of tyre/road noise; Was kann die gehoergerechte Schallmesstechnik zur zukunftsorientierten Gestaltung des Reifen-/Fahrbahngeraeusches beitragen?

    Energy Technology Data Exchange (ETDEWEB)

    Genuit, K. [HEAD acoustics, Herzogenrath-Kohlscheid (Germany); Poggenburg, J.

    1998-12-31

    The share of tyre noise in the total motor car noise has increased constantly in the past years. Today, legal regulations governing car noise and the car industry`s increasing demands on driving comfort are forcing car tyre producers to reduce tyre noise. This is made more difficult by the high and varied demands on tyres. The authors therefore suggest that rolling noise design should be given more attention supplementary to the current noise level measurements. This would result in a product-specific type of noise and also enhance the social acceptance of motor cars. The limits of conventional measuring techniques are pointed out, as are the possibilities of binaural measurement and analysis. Exemplary applications are listed, and an outlook to the future is attempted. [Deutsch] Der prozentuale Anteil der Reifen am Gesamtgeraeusch eines Fahrzeuges ist in der Vergangenheit stetig angestiegen. Bestehende gesetzliche Vorschriften fuer das Fahrzeug-Aussengeraeusch sowie hohe Ansprueche der Kunden, d.h. primaer der Automobilindustrie, zwingen die Reifenhersteller generell, das Rollgeraeusch zu reduzieren. Die an einen Fahrzeugreifen gestellten vielfaeltigen Anforderungen bedingen hierbei im allgemeinen einen hohen Aufwand. Im Beitrag wird daher fuer eine Vorgehensweise plaediert, die in Ergaenzung zum begrenzt aussagekraeftigen A-bewerteten Schalldruckpegel eine Gestaltung des Rollgeraeusches in den Mittelpunkt stellt. Hiermit kann nicht nur die Realisierung eines produktbezogenen Aussengeraeusches unterstuetzt werden, sondern es sichert darueber hinaus die gesellschaftliche Akzeptanz des Autos. Es werden die Grenzen konventioneller Messverfahren kurz aufgezeigt und die mittels binauraler Mess- und Analysetechnik bestehenden Moeglichkeiten dargestellt. Sinnvolle Vorgehensweisen werden anhand verschiedener Anwendungsbeispiele erlaeutert. Ein abschliessender Ausblick beschreibt das Potential zur Reduzierung der Belaestigungswirkung von Reifengeraeuschen durch

  10. Identification of Non-Faradaic Processes by Measurement of the Electrochemical Peltier Heat during the Silver Underpotential Deposition on Au(111).

    Science.gov (United States)

    Frittmann, Stefan; Halka, Vadym; Schuster, Rolf

    2016-04-04

    We measured the heat which is reversibly exchanged during the course of an electrochemical surface reaction, i.e., the deposition/dissolution of the first two monolayers of Ag on a Au(111) surface in (bi)sulfate and perchlorate containing electrolytes. The reversibly exchanged heat corresponds to the Peltier heat of the reaction and is linearly related to its entropy change, including also non-Faradaic side processes. Hence, the measurement of the Peltier heat provides thermodynamic information on the electrochemical processes which is complementary to the current-potential relations usually obtained by conventional electrochemical methods. From the variation of the molar Peltier heat during the various stages of the deposition reaction we inferred that co-adsorption processes of anions and Ag do not play a prominent role, while we find strong indications for a charge neutral substitution reaction of adsorbed anions by hydroxide, which would not show up in cyclic voltammetry. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Research on electrochemical methods for concentration measurement of dissolved ion in molten salt to apply to electrolytic process control. Innovative research adopted in 2002 fiscal year

    International Nuclear Information System (INIS)

    Nagai, Takayuki

    2005-03-01

    The purpose of this research is to establish the online (in-situ) technique for concentration measuring of dissolved ion in the molten salt, and this technique is due to the electrochemical method for the concentration measuring of dissolved ion in solutions like the polarization curve measurement. This research executed the following four items. 1) Examination of possibility for concentration measuring of dissolved ion in molten salt by cyclic voltammetry. 2) Examination of possibility for concentration measuring of dissolved ion in molten salt by various electrochemical methods. 3) Examination of suitable electrochemical method for concentration measuring of dissolved ion. 4) Confirmation of selected electrochemical method for concentration measuring of dissolved ion. It has been understood that the differential pulse voltammetry (DPV) is a promising electrochemical technique for the concentration measuring of dissolved ion in the molten salt as a result of this research. An appropriate measurement condition is as follows, the potential sweep rate is -0.1 V/s, the pulse cycle is 0.1 s, the pulse width is 10 ms, and the pulse voltage is 50 mV. As for the electrodes, the platinum working electrode, the glassy carbon counter electrode, and silver/silver chloride reference electrode are suitable. Moreover, the molar absorptivities of U 3+ , U 4+ , UO 2 + , UO 2 2+ , and the standard redox potentials of couples of U 4+ /U 3+ and UO 2 2+ /UO 2 + were acquired as a basic data of the uranium and the uranyl ion in molten NaCl-2CsCl. (author)

  12. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    International Nuclear Information System (INIS)

    Xue, Zhenyu; Charonko, John J; Vlachos, Pavlos P

    2014-01-01

    In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we extend the original work by Charonko and Vlachos and present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. Several corrections have been applied in this work. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations by applying a subtraction of the minimum correlation value to remove the effect of the background image noise. In addition, the notion of a ‘valid’ measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an ‘outlier’ measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to more robust and reliable uncertainty estimation models compared with the original work by Charonko and Vlachos. The models are tested against both synthetic benchmark data as well as experimental measurements. In this work, U 68.5 uncertainties are estimated at the 68.5% confidence level while U 95 uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical confidence intervals, thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements. (paper)

  13. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    Science.gov (United States)

    Xue, Zhenyu; Charonko, John J.; Vlachos, Pavlos P.

    2014-11-01

    In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we extend the original work by Charonko and Vlachos and present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. Several corrections have been applied in this work. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations by applying a subtraction of the minimum correlation value to remove the effect of the background image noise. In addition, the notion of a ‘valid’ measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an ‘outlier’ measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to more robust and reliable uncertainty estimation models compared with the original work by Charonko and Vlachos. The models are tested against both synthetic benchmark data as well as experimental measurements. In this work, {{U}68.5} uncertainties are estimated at the 68.5% confidence level while {{U}95} uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical confidence intervals, thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements.

  14. CRITERIA OF THE AVIATION NOISE ASSESSMENT FOR AERODROME ENVIRONS ZONING OF THE AIRPORTS AND PROTECTIVE MEASURES JUSTIFICATION

    Directory of Open Access Journals (Sweden)

    Oleg A. Kartyshev

    2017-01-01

    Full Text Available Problems in the sphere of an adverse ecological effect assessment of aerodrome environs aviation noise are analyzed. It is noted, that there is no modern standard and methodical base for such assessment. It is shown that when planning the build- ing, and also when developing noise-protective actions for residential areas in the zones of aviation noise increased level im- pact it’s most effectively to carry out acoustic zoning of areas near airports borders and flight routes. The system of transport sources noise rationing in Russia doesn't consider the established practice of its application. The aircraft of noisy types were actively taken out of service and aviation noise impact near the airports decreased, but the problem of noise protection, de- mands control when planning land use. Noise measurements in residential areas, near houses and inside, showed the excess of maximum allowed level values to 25-35 dBA (on equivalent value and to 25-40 dBA (on the maximum value.As a consequence of the European states policy in the sphere of aviation noise management and of aerodrome en- virons zoning noise levels at the airports of Europe and their surroundings were stabilized and the sizes of noise contours were reduced. For different countries there was made the analysis of legislative bases of the implementation of the re-striction requirement for residential areas and the possibility of using the territory under noise impact. For rationing theaerodrome environs noise of the airports it’s offered to take a sound equivalent level in which admissible values are ranged on three zones for the main standard criterion. The authors present acoustic measurements results in houses near the airport Vnukovo on condition of using standard two-chamber trimmable and folding windows with the ventilating valve. It is shown that the popular window designs can't provide inside noise reduction at night to the standard L Amax level = 45 dBA from the aviation source

  15. Predetermining acceptable noise limits of EXAFS spectra in the limit of stochastic noise

    International Nuclear Information System (INIS)

    Hu, Yung-Jin; Booth, Corwin H

    2009-01-01

    The effect of stochastic noise on Extended X-ray Absorption Fine Structure (EXAFS) data measurement, analysis, and fitting is discussed. Stochastic noise reduces the ability to uniquely fit a calculated model to measured EXAFS data. Such noise can be reduced by common methods that increase the signal-to-noise ratio; however, these methods are not always practical. Therefore, predetermined, quantitative knowledge of the level of acceptable stochastic noise when fitting for a particular model system is essential in maximizing the chances of a successful EXAFS experiment and minimizing wasted beamtime. This paper outlines a method to estimate, through simulation, the acceptable level of stochastic noise in EXAFS spectra that still allows a successful test of a proposed model compound.

  16. High temperature and pressure electrochemical test station

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Allebrod, Frank; Mogensen, Mogens Bjerg

    2013-01-01

    An electrochemical test station capable of operating at pressures up to 100 bars and temperatures up to 400 ◦C has been established. It enables control of the partial pressures and mass flow of O2, N2, H2, CO2, and H2O in a single or dual environment arrangement, measurements with highly corrosive...... media, as well as localized sampling of gas evolved at the electrodes for gas analysis. A number of safety and engineering design challenges have been addressed. Furthermore, we present a series of electrochemical cell holders that have been constructed in order to accommodate different types of cells...... and facilitate different types of electrochemical measurements. Selected examples of materials and electrochemical cells examined in the test station are provided, ranging from the evaluation of the ionic conductivity of liquid electrolytic solutions immobilized in mesoporous ceramic structures...

  17. Rapid measurement of auditory filter shape in mice using the auditory brainstem response and notched noise.

    Science.gov (United States)

    Lina, Ioan A; Lauer, Amanda M

    2013-04-01

    The notched noise method is an effective procedure for measuring frequency resolution and auditory filter shapes in both human and animal models of hearing. Briefly, auditory filter shape and bandwidth estimates are derived from masked thresholds for tones presented in noise containing widening spectral notches. As the spectral notch widens, increasingly less of the noise falls within the auditory filter and the tone becomes more detectible until the notch width exceeds the filter bandwidth. Behavioral procedures have been used for the derivation of notched noise auditory filter shapes in mice; however, the time and effort needed to train and test animals on these tasks renders a constraint on the widespread application of this testing method. As an alternative procedure, we combined relatively non-invasive auditory brainstem response (ABR) measurements and the notched noise method to estimate auditory filters in normal-hearing mice at center frequencies of 8, 11.2, and 16 kHz. A complete set of simultaneous masked thresholds for a particular tone frequency were obtained in about an hour. ABR-derived filter bandwidths broadened with increasing frequency, consistent with previous studies. The ABR notched noise procedure provides a fast alternative to estimating frequency selectivity in mice that is well-suited to high through-put or time-sensitive screening. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Determination of the energy gap in photoconducting insulators through current noise measurements

    International Nuclear Information System (INIS)

    Carbone, A.; Demichelis, F.; Mazzetti, P.

    1989-01-01

    Measurements of the current noise power spectrum of the photoconducting insulators CdS and CdSe irradiated with monochromatic light of different wavelength λ are reported. It is shown that there is an abrupt change of about one order of magnitude in the low frequency power density of the noise when λ crosses the photoconductor gap value λ and the photocurrent and the device conductance are kept constant by varying the light intensity. The effect is explained in terms of an abrupt increase of the carrier recombination rate when the photon energy becomes larger than the energy gap of the photoconductor. Possible applications of these results are briefly discussed

  19. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    Science.gov (United States)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  20. Shot noise limit of the optical 3D measurement methods for smooth surfaces

    Czech Academy of Sciences Publication Activity Database

    Pavlíček, Pavel; Pech, Miroslav

    2016-01-01

    Roč. 27, č. 3 (2016), 1-7, č. článku 035205. ISSN 0957-0233 R&D Projects: GA ČR GA13-12301S Institutional support: RVO:68378271 Keywords : measurement uncertainty * shot noise * 3D measurement * interferometry Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.585, year: 2016

  1. Noise and LPI radar as part of counter-drone mitigation system measures

    Science.gov (United States)

    Zhang, Yan (Rockee); Huang, Yih-Ru; Thumann, Charles

    2017-05-01

    With the rapid proliferation of small unmanned aerial systems (UAS) in the national airspace, small operational drones are being sometimes considered as a security threat for critical infrastructures, such as sports stadiums, military facilities, and airports. There have been many civilian counter-drone solutions and products reported, including radar and electromagnetic counter measures. For the current electromagnetic solutions, they are usually limited to particular type of detection and counter-measure scheme, which is usually effective for the specific type of drones. Also, control and communication link technologies used in even RC drones nowadays are more sophisticated, making them more difficult to detect, decode and counter. Facing these challenges, our team proposes a "software-defined" solution based on noise and LPI radar. For the detection, wideband-noise radar has the resolution performance to discriminate possible micro-Doppler features of the drone versus biological scatterers. It also has the benefit of more adaptive to different types of drones, and covertly detecting for security application. For counter-measures, random noise can be combined with "random sweeping" jamming scheme, to achieve the optimal balance between peak power allowed and the effective jamming probabilities. Some theoretical analysis of the proposed solution is provided in this study, a design case study is developed, and initial laboratory experiments, as well as outdoor tests are conducted to validate the basic concepts and theories. The study demonstrates the basic feasibilities of the Drone Detection and Mitigation Radar (DDMR) concept, while there are still much work needs to be done for a complete and field-worthy technology development.

  2. Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU

    Directory of Open Access Journals (Sweden)

    Vahideh Abolhasannejad

    2014-11-01

    Results: Mean sound pressure level for GICU was 60.9±1/6 dBA that is more than the standard level. The mean of maximum noise level was obtained 82.5±2 dBA and the highest noise level was measured at nursing station. There was significant difference in Noise Pollution level based on different months, level of patient's conciseness and number of ventilator using (P < 0.05. Conclusion: Being more noise pollution in the ICU and stations on all shifts may cause to diminish health and well-being of the staff in long-term and produce some problems for the patient. According to the highest level of noise produced in nursing stations and the different activities doing by the staff as a main noise pollution factor, it's necessary to perform required training in relationship with doing the works in right manner so that we can produce quiet and silence environment for patience.

  3. A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1988-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the /sup 252/Cf-source-driven neutron noise analysis method. The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcritical neutron multiplication factor of a configuration of fissile material requires measurement of the frequency-dependent cross-power spectral density (CPSD), G/sub 23/(ω), between a pair of detectors (Nos. 2 and 3) located in or near the fissile material and CPSDs G/sub 12/(ω) and G/sub 13/(ω) between these same detectors and a source of neutrons emanating from an ionization chamber (No. 1) containing /sup 252/Cf, also positioned in or near the fissile material. The auto-power spectral density (APSD), G/sub 11/(ω), of the source is also required. A particular ratio of spectral densities, G/sub 12//sup */G/sub 13//G/sub 11/G/sub 23/ (/sup */ denotes complex conjugation), is then formed. This ratio is related to the subcritical neutron multiplication factor and is independent of detector efficiencies

  4. Measurement of multiple α-modes at the Delphi subcritical assembly by neutron noise techniques

    International Nuclear Information System (INIS)

    Szieberth, Máté; Klujber, Gergely; Kloosterman, Jan Leen; Haas, Dick de

    2015-01-01

    Highlights: • Neutron noise measurements were performed at the Delphi subcritical assembly. • Bias in the fitted prompt decay constant was observed due to higher modes. • Spatial dependence of the higher mode was surveyed. • Effect of two different source distributions was investigated. • An estimation of the prompt decay constant is given for the Delphi. - Abstract: The paper presents the results and evaluations of a comprehensive set of neutron noise measurements on the Delphi subcritical assembly of the Delft University of Technology. The measurements investigated the effect of different source distributions (inherent spontaneous fission and 252 Cf) and the position of the detectors applied (both radially and vertically). The evaluation of the measured data has been performed by the variance-to-mean (VTM, Feynman-α), the autocorrelation (ACF, Rossi-α) and the cross-correlation (CCF) methods. The values obtained for the prompt decay constant show a strong bias, which depends both on the detector position and on the source distribution. This is due to the presence of higher modes in the system. It has been observed that the α value fitted is higher when the detector is close to the boundary of the core or to the 252 Cf point-source. The higher alpha-modes have also been observed by fitting functions describing two alpha-modes. The successful set of measurements also provides a good basis for further theoretical investigations including the Monte Carlo simulation of the noise measurements and the calculation of the alpha-modes in the Delphi subcritical assembly

  5. Noise, air pollutants and traffic: continuous measurement and correlation at a high-traffic location in New York City.

    Science.gov (United States)

    Ross, Zev; Kheirbek, Iyad; Clougherty, Jane E; Ito, Kazuhiko; Matte, Thomas; Markowitz, Steven; Eisl, Holger

    2011-11-01

    Epidemiological studies have linked both noise and air pollution to common adverse health outcomes such as increased blood pressure and myocardial infarction. In urban settings, noise and air pollution share important sources, notably traffic, and several recent studies have shown spatial correlations between noise and air pollution. The temporal association between these exposures, however, has yet to be thoroughly investigated despite the importance of time series studies in air pollution epidemiology and the potential that correlations between these exposures could at least partly confound statistical associations identified in these studies. An aethelometer, for continuous elemental carbon measurement, was co-located with a continuous noise monitor near a major urban highway in New York City for six days in August 2009. Hourly elemental carbon measurements and hourly data on overall noise levels and low, medium and high frequency noise levels were collected. Hourly average concentrations of fine particles and nitrogen oxides, wind speed and direction and car, truck and bus traffic were obtained from nearby regulatory monitors. Overall temporal patterns, as well as day-night and weekday-weekend patterns, were characterized and compared for all variables. Noise levels were correlated with car, truck, and bus traffic and with air pollutants. We observed strong day-night and weekday-weekend variation in noise and air pollutants and correlations between pollutants varied by noise frequency. Medium and high frequency noise were generally more strongly correlated with traffic and traffic-related pollutants than low frequency noise and the correlation with medium and high frequency noise was generally stronger at night. Correlations with nighttime high frequency noise were particularly high for car traffic (Spearman rho=0.84), nitric oxide (0.73) and nitrogen dioxide (0.83). Wind speed and direction mediated relationships between pollutants and noise. Noise levels are

  6. Laser phase and frequency noise measurement by Michelson interferometer composed of a 3 × 3 optical fiber coupler.

    Science.gov (United States)

    Xu, Dan; Yang, Fei; Chen, Dijun; Wei, Fang; Cai, Haiwen; Fang, Zujie; Qu, Ronghui

    2015-08-24

    A laser phase and frequency noise measurement method by an unbalanced Michelson interferometer composed of a 3 × 3 optical fiber coupler is proposed. The relations and differences of the power spectral density (PSD) of differential phase and frequency fluctuation, PSD of instantaneous phase and frequency fluctuation, phase noise and linewidth are derived strictly and discussed carefully. The method obtains the noise features of a narrow linewidth laser conveniently without any specific assumptions or noise models. The technique is also used to characterize the noise features of a narrow linewidth external-cavity semiconductor laser, which confirms the correction and robustness of the method.

  7. Wind noise under a pine tree canopy.

    Science.gov (United States)

    Raspet, Richard; Webster, Jeremy

    2015-02-01

    It is well known that infrasonic wind noise levels are lower for arrays placed in forests and under vegetation than for those in open areas. In this research, the wind noise levels, turbulence spectra, and wind velocity profiles are measured in a pine forest. A prediction of the wind noise spectra from the measured meteorological parameters is developed based on recent research on wind noise above a flat plane. The resulting wind noise spectrum is the sum of the low frequency wind noise generated by the turbulence-shear interaction near and above the tops of the trees and higher frequency wind noise generated by the turbulence-turbulence interaction near the ground within the tree layer. The convection velocity of the low frequency wind noise corresponds to the wind speed above the trees while the measurements showed that the wind noise generated by the turbulence-turbulence interaction is near stationary and is generated by the slow moving turbulence adjacent to the ground. Comparison of the predicted wind noise spectrum with the measured wind noise spectrum shows good agreement for four measurement sets. The prediction can be applied to meteorological estimates to predict the wind noise under other pine forests.

  8. Background noise levels measured in the NASA Lewis 9- by 15-foot low-speed wind tunnel

    Science.gov (United States)

    Woodward, Richard P.; Dittmar, James H.; Hall, David G.; Kee-Bowling, Bonnie

    1994-01-01

    The acoustic capability of the NASA Lewis 9 by 15 Foot Low Speed Wind Tunnel has been significantly improved by reducing the background noise levels measured by in-flow microphones. This was accomplished by incorporating streamlined microphone holders having a profile developed by researchers at the NASA Ames Research Center. These new holders were fabricated for fixed mounting on the tunnel wall and for an axially traversing microphone probe which was mounted to the tunnel floor. Measured in-flow noise levels in the tunnel test section were reduced by about 10 dB with the new microphone holders compared with those measured with the older, less refined microphone holders. Wake interference patterns between fixed wall microphones were measured and resulted in preferred placement patterns for these microphones to minimize these effects. Acoustic data from a model turbofan operating in the tunnel test section showed that results for the fixed and translating microphones were equivalent for common azimuthal angles, suggesting that the translating microphone probe, with its significantly greater angular resolution, is preferred for sideline noise measurements. Fixed microphones can provide a local check on the traversing microphone data quality, and record acoustic performance at other azimuthal angles.

  9. Measurement of reactivity temperature coefficient by noise method in a power reactor

    International Nuclear Information System (INIS)

    Aguilar, O.

    1986-07-01

    The temperature reactivity coefficient was estimated on the basis of noise measurements performed in a PWR. The magnitude of the coefficient was evaluated by relating the values of the APSD and CPSD between ex-core neutron detector signals and fuel assembly outlet thermocouple in the low frequency range. Comparison with δρ/δT measurements performed in PWR by standard methods supports the validity of the results. (author)

  10. A Ratiometric Method for Johnson Noise Thermometry Using a Quantized Voltage Noise Source

    Science.gov (United States)

    Nam, S. W.; Benz, S. P.; Martinis, J. M.; Dresselhaus, P.; Tew, W. L.; White, D. R.

    2003-09-01

    Johnson Noise Thermometry (JNT) involves the measurement of the statistical variance of a fluctuating voltage across a resistor in thermal equilibrium. Modern digital techniques make it now possible to perform many functions required for JNT in highly efficient and predictable ways. We describe the operational characteristics of a prototype JNT system which uses digital signal processing for filtering, real-time spectral cross-correlation for noise power measurement, and a digitally synthesized Quantized Voltage Noise Source (QVNS) as an AC voltage reference. The QVNS emulates noise with a constant spectral density that is stable, programmable, and calculable in terms of known parameters using digital synthesis techniques. Changes in analog gain are accounted for by alternating the inputs between the Johnson noise sensor and the QVNS. The Johnson noise power at a known temperature is first balanced with a synthesized noise power from the QVNS. The process is then repeated by balancing the noise power from the same resistor at an unknown temperature. When the two noise power ratios are combined, a thermodynamic temperature is derived using the ratio of the two QVNS spectral densities. We present preliminary results where the ratio between the gallium triple point and the water triple point is used to demonstrate the accuracy of the measurement system with a standard uncertainty of 0.04 %.

  11. Combat aircraft noise

    Science.gov (United States)

    Sgarbozza, M.; Depitre, A.

    1992-04-01

    A discussion of the characteristics and the noise levels of combat aircraft and of a transport aircraft in taking off and landing are presented. Some methods of noise reduction are discussed, including the following: operational anti-noise procedures; and concepts of future engines (silent post-combustion and variable cycle). Some measurement results concerning the noise generated in flight at great speeds and low altitude will also be examined. Finally, the protection of the environment of French air bases against noise will be described and the possibilities of regulation examined.

  12. Environmental noise and noise modelling-some aspects in Malaysian development

    International Nuclear Information System (INIS)

    Leong, Mohd Salman; Mohd Shafiek bin Hj Yaacob

    1994-01-01

    Environmental noise is of growing concern in Malaysia with the increasing awareness of the need for an environmental quality consistent with improved quality of life. While noise is one of the several elements in an Environmental Impact Assessment report, the degree of emphasis in the assessment is not as thorough as other aspects in the EIA study. The measurements, prediction (if at all any), and evaluation tended to be superficial. The paper presents a summary of correct noise descriptors and annoyance assessment parameters appropriate for the evaluation of environmental noise. The paper further highlights current inadequacies in the Environmental Quality Act for noise pollution, and annoyance assessment. Some examples of local noise pollution are presented. A discussion on environmental noise modelling is presented. Examples illustrating environmental noise modelling for a mining operation and a power station are given. It is the authors' recommendation that environmental noise modelling be made mandatory in all EIA studies such that a more definitive assessment could be realised

  13. A new IEA document for the measurement of noise immission from wind turbines at receptor locations

    International Nuclear Information System (INIS)

    Ljunggren, Sten

    1999-01-01

    A new IEA guide on acoustic noise was recently completed by an international expert group. In this guide, several practical and reliable methods for determining wind turbine noise immission at receptor locations are presented: three methods for equivalent continuous A-weighted sound pressure levels and one method for A-weighted percentiles. In the most ambitious method for equivalent sound levels, the noise is measured together with the wind speed at two locations: one at the microphone and the other at the turbine site. With this approach, the turbine levels can be corrected for background sound and the immission level can be determined at a certain target speed. Special importance is attached to the problem of correcting for background noise and to techniques for improving the signal-to-noise ratio. Thus, six methods are described which can be used in difficult situations

  14. Real-Time Telemetry System for Amperometric and Potentiometric Electrochemical Sensors

    Directory of Open Access Journals (Sweden)

    Ching-Hsing Luo

    2011-09-01

    Full Text Available A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC, a microcontroller unit (MCU, a graphical user interface (GUI, and a radio frequency (RF transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA. The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment, a small size of 5.6 cm × 8.7 cm, high portability, and high integration.

  15. Noise-induced hearing loss: a recreational noise perspective.

    Science.gov (United States)

    Ivory, Robert; Kane, Rebecca; Diaz, Rodney C

    2014-10-01

    This review will discuss the real-world risk factors involved in noise-induced hearing loss as a result of common and popular recreational activities prone to mid and high levels of noise exposure. Although there are currently no interventional measures available to reverse or mitigate preexisting hearing loss from noise, we discuss the vital importance of hearing loss prevention from noise exposure avoidance and reduction. Despite a seeming understanding of the effects of noise exposure from various recreational activities and devices, a large percentage of the general public who is at risk of such noise-induced hearing loss still chooses to refrain from using hearing protection instruments. While occupational exposures pose the greatest traditional risk to hearing conservation in selected workers, recreational risk factors for noise-induced hearing loss may be more insidious in overall effect given the indifferent attitude of much of the general public and particularly our youths toward hearing protection during recreational activities. Active counseling regarding the consequences of excessive noise exposure and the potential benefits to hearing from usage of hearing protection instruments is critical to providing best possible care in the hearing health professions.

  16. Wide-band residual phase-noise measurements on 40-GHz monolithic mode-locked lasers

    DEFF Research Database (Denmark)

    Larsson, David; Hvam, Jørn Märcher

    2005-01-01

    We have performed wide-band residual phase-noise measurements on semiconductor 40-GHz mode-locked lasers by employing electrical waveguide components for the radio-frequency circuit. The intrinsic timing jitters of lasers with one, two, and three quantum wells (QW) are compared and our design......-QW laser. There is good agreement between the measured results and existing theory....

  17. Entanglement enhancement through multirail noise reduction for continuous-variable measurement-based quantum-information processing

    Science.gov (United States)

    Su, Yung-Chao; Wu, Shin-Tza

    2017-09-01

    We study theoretically the teleportation of a controlled-phase (cz) gate through measurement-based quantum-information processing for continuous-variable systems. We examine the degree of entanglement in the output modes of the teleported cz-gate for two classes of resource states: the canonical cluster states that are constructed via direct implementations of two-mode squeezing operations and the linear-optical version of cluster states which are built from linear-optical networks of beam splitters and phase shifters. In order to reduce the excess noise arising from finite-squeezed resource states, teleportation through resource states with different multirail designs will be considered and the enhancement of entanglement in the teleported cz gates will be analyzed. For multirail cluster with an arbitrary number of rails, we obtain analytical expressions for the entanglement in the output modes and analyze in detail the results for both classes of resource states. At the same time, we also show that for uniformly squeezed clusters the multirail noise reduction can be optimized when the excess noise is allocated uniformly to the rails. To facilitate the analysis, we develop a trick with manipulations of quadrature operators that can reveal rather efficiently the measurement sequence and corrective operations needed for the measurement-based gate teleportation, which will also be explained in detail.

  18. Measurement and analysis of self-noise in hybrid-driven underwater gliders

    Directory of Open Access Journals (Sweden)

    LIU Lu

    2017-08-01

    Full Text Available The Hybrid-driven Underwater Glider (HUG is a new type of submersible vehicle which combines the functions of traditional Autonomous Underwater Vehicles(AUVand Autonomous Underwater Gliders(AUG. In order to study its noise source distribution and basic self-noise characteristics, a self-noise acquisition system based on the HUG was designed and developed, and a noise analysis test carried out in a free-field pool. In August 2016, the sea trial of the Petrel II glider was conducted in the South China Sea, with observation data at a depth range of 1 000 m as the research object. The self-noise data of the glider platform under different working conditions was obtained through the step-by-step operation method. The experimental analysis and results show that the self-noise acquisition system is stable. The contribution of mechanical noise to self-noise is greatest when the glider works in the gliding mode, while the self-noise band above 500 Hz is closely related to the work of the buoyancy adjustment unit, and peaks at 1 kHz. According to the analysis of the basic characteristics of self-noise, this provides some guidance for the implementation of vibration and noise reduction.

  19. Resolution and noise measurements of five CRT and LCD medical displays

    International Nuclear Information System (INIS)

    Saunders, Robert S. Jr.; Samei, Ehsan

    2006-01-01

    The performance of soft-copy displays plays a significant role in the overall image quality of a digital radiographic system. In this work, we discuss methods to characterize the resolution and noise of both cathode ray tube (CRT) and liquid crystal display (LCD) devices. We measured the image quality of five different commercial display devices, representing both CRT and LCD technologies, using a high-quality charge-coupled device (CCD) camera. The modulation transfer function (MTF) was calculated using the line technique, correcting for the MTF of the CCD camera and the display pixel size. The normalized noise power spectrum (NPS) was computed from two-dimensional Fourier analysis of uniform images. To separate the effects of pixel structure from interpixel luminance variations, we created structure-free images by eliminating the pixel structures of the display device. The NPS was then computed from these structure-free images to isolate interpixel luminance variations. We found that the MTF of LCDs remained close to the theoretical limit dictated by their inherent pixel size (0.85±0.08 at Nyquist frequency), in contrast to the MTF for the two CRT displays, which dropped to 0.15±0.08 at the Nyquist frequency. However, the NPS of LCDs showed significant peaks due to the subpixel structure, while the NPS of CRT displays exhibited a nearly flat power spectrum. After removing the pixel structure, the structured noise peaks for LCDs were eliminated and the overall noise magnitude was significantly reduced. The average total noise-to-signal ratio for CRT displays was 6.55%±0.59%, of which 6.03%±0.24% was due to interpixel luminance variations, while LCD displays had total noise to signal ratios of 46.1%±5.1% of which 1.50%±0.41% were due to interpixel luminance variations. Depending on the extent of the blurring and prewhitening processes of the human visual system, the magnitude of the display noise (including pixel structure) potentially perceived by the

  20. Physics of the 252Cf-source-driven noise analysis measurement

    International Nuclear Information System (INIS)

    Valentine, T.E.; Mihalczo, J.T.; Perez, R.B.; Mattingly, J.K.

    1997-01-01

    The 252 Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method's broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, coherences, and ratios of spectral densities. All of these measured parameters can also be calculated using the MCNP-DSP Monte Carlo code. This paper presents a review of the time-domain signatures obtained from this measurement

  1. Probing in-plane anisotropy in few-layer ReS2 using low frequency noise measurement

    Science.gov (United States)

    Mitra, Richa; Jariwala, Bhakti; Bhattacharya, Arnab; Das, Anindya

    2018-04-01

    ReS2, a layered two-dimensional material popular for its in-plane anisotropic properties, is emerging as one of the potential candidates for flexible electronics and ultrafast optical applications. It is an n-type semiconducting material having a layer independent bandgap of 1.55 eV. In this paper we have characterized the intrinsic electronic noise level of few-layer ReS2 for the first time. Few-layer ReS2 field effect transistor devices show a 1/f nature of noise for frequency ranging over three orders of magnitude. We have also observed that not only the electrical response of the material is anisotropic; the noise level is also dependent on direction. In fact the noise is found to be more sensitive towards the anisotropy. This fact has been explained by evoking the theory where the Hooge parameter is not a constant quantity, but has a distinct power law dependence on mobility along the two-axes direction. The anisotropy in 1/f noise measurement will pave the way to quantify the anisotropic nature of two-dimensional (2D) materials, which will be helpful for the design of low-noise transistors in future.

  2. Optimal Linear Filters. 2. Pulse Time Measurements in the Presence of Noise

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, K

    1966-09-15

    The problem of calculating the maximum available timing information contained in nuclear pulses in the presence of noise is solved theoretically. Practical experiments show that the theoretical values can be obtained by very simple, but untraditional, means. An output pulse from a practical filter connected to a charge sensitive amplifier with a Ge(Li) detector showed a rise time of 30 ns and a noise level of less than 5 keV. The time jitter measured was inversely proportional to the pulse height and less than 30 ns for 10 keV pulses. With the timing filter shown solid state detectors can be classified somewhere between Nal scintillators and organic scintillators with respect to time resolution.

  3. Optimal Linear Filters. 2. Pulse Time Measurements in the Presence of Noise

    International Nuclear Information System (INIS)

    Nygaard, K.

    1966-09-01

    The problem of calculating the maximum available timing information contained in nuclear pulses in the presence of noise is solved theoretically. Practical experiments show that the theoretical values can be obtained by very simple, but untraditional, means. An output pulse from a practical filter connected to a charge sensitive amplifier with a Ge(Li) detector showed a rise time of 30 ns and a noise level of less than 5 keV. The time jitter measured was inversely proportional to the pulse height and less than 30 ns for 10 keV pulses. With the timing filter shown solid state detectors can be classified somewhere between Nal scintillators and organic scintillators with respect to time resolution

  4. Measurement and Analysis of the Noise Radiated by Low Mach Number Centrifugal Blowers.

    Science.gov (United States)

    Yeager, David Marvin

    An investigation was performed of the broad band, aerodynamically generated noise in low tip-speed Mach number, centrifugal air moving devices. An interdisciplinary experimental approach was taken which involved investigation of the aerodynamic and acoustic fields, and their mutual relationship. The noise generation process was studied using two experimental vehicles: (1) a scale model of a homologous family of centrifugal blowers typical of those used to cool computer and business equipment, and (2) a single blade from a centrifugal blower impeller placed in a known, controllable flow field. The radiation characteristics of the model blower were investigated by measuring the acoustic intensity distribution near the blower inlet and comparing it with the intensity near the inlet to an axial flow fan. Results showed that the centrifugal blower is a distributed, random noise source, unlike an axial fan which exhibited the effects of a coherent, interacting source distribution. Aerodynamic studies of the flow field in the inlet and at the discharge to the rotating impeller were used to assess the mean flow distribution through the impeller blade channels and to identify regions of excessive turbulence near the rotating blade row. Both circumferential and spanwise mean flow nonuniformities were identified along with a region of increased turbulence just downstream of the scroll cutoff. The fluid incidence angle, normally taken as an indicator of blower performance, was estimated from mean flow data as deviating considerably from an ideal impeller design. An investigation of the noise radiated from the single, isolated airfoil was performed using modern correlation and spectral analysis techniques. Radiation from the single blade in flow was characterized using newly developed expressions for the correlation area and the dipole source strength per unit area, and from the relationship between the blade surface pressure and the incident turbulent flow field. Results

  5. Relations Between the Intelligibility of Speech in Noise and Psychophysical Measures of Hearing Measured in Four Languages Using the Auditory Profile Test Battery

    Directory of Open Access Journals (Sweden)

    T. E. M. Van Esch

    2015-12-01

    Full Text Available The aim of the present study was to determine the relations between the intelligibility of speech in noise and measures of auditory resolution, loudness recruitment, and cognitive function. The analyses were based on data published earlier as part of the presentation of the Auditory Profile, a test battery implemented in four languages. Tests of the intelligibility of speech, resolution, loudness recruitment, and lexical decision making were measured using headphones in five centers: in Germany, the Netherlands, Sweden, and the United Kingdom. Correlations and stepwise linear regression models were calculated. In sum, 72 hearing-impaired listeners aged 22 to 91 years with a broad range of hearing losses were included in the study. Several significant correlations were found with the intelligibility of speech in noise. Stepwise linear regression analyses showed that pure-tone average, age, spectral and temporal resolution, and loudness recruitment were significant predictors of the intelligibility of speech in fluctuating noise. Complex interrelationships between auditory factors and the intelligibility of speech in noise were revealed using the Auditory Profile data set in four languages. After taking into account the effects of pure-tone average and age, spectral and temporal resolution and loudness recruitment had an added value in the prediction of variation among listeners with respect to the intelligibility of speech in noise. The results of the lexical decision making test were not related to the intelligibility of speech in noise, in the population studied.

  6. Low noise multi-channel biopotential wireless data acquisition system for dry electrodes

    Science.gov (United States)

    Pandian, P. S.; Whitchurch, Ashwin K.; Abraham, Jose K.; Bhusan Baskey, Himanshu; Radhakrishnan, J. K.; Varadan, Vijay K.; Padaki, V. C.; Bhasker Rao, K. U.; Harbaugh, R. E.

    2008-03-01

    The bioelectrical potentials generated within the human body are the result of electrochemical activity in the excitable cells of the nervous, muscular or glandular tissues. The ionic potentials are measured using biopotential electrodes which convert ionic potentials to electronic potentials. The commonly monitored biopotential signals are Electrocardiogram (ECG), Electroencephalogram (EEG) and Electromyogram (EMG). The electrodes used to monitor biopotential signals are Ag-AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gels used in biopotential recordings dry out when used for longer durations and add noise to the signals and also prolonged use of gels cause irritations and rashes to skin. Also noises such as motion artifact and baseline wander are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry electrodes are used, where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The major drawback associated with the dry electrodes is the high skin-electrode impedance in the low frequency range between 0.1-120 Hz, which makes it difficult to acquire clean and noise free biopotential signals. The paper presents the design and development of biopotential data acquisition and processing system to acquire biopotential signals from dry electrodes. The electrode-skin-electrode- impedance (ESEI) measurements was carried out for the dry electrodes by impedance spectroscopy. The biopotential signals are processed using an instrumentation amplifier with high CMRR and high input impedance achieved by boot strapping the input terminals. The signals are band limited by means of a second order Butterworth band pass filters to eliminate noise. The processed biopotential signals are digitized

  7. Deep-water measurements of container ship radiated noise signatures and directionality.

    Science.gov (United States)

    Gassmann, Martin; Wiggins, Sean M; Hildebrand, John A

    2017-09-01

    Underwater radiated noise from merchant ships was measured opportunistically from multiple spatial aspects to estimate signature source levels and directionality. Transiting ships were tracked via the Automatic Identification System in a shipping lane while acoustic pressure was measured at the ships' keel and beam aspects. Port and starboard beam aspects were 15°, 30°, and 45° in compliance with ship noise measurements standards [ANSI/ASA S12.64 (2009) and ISO 17208-1 (2016)]. Additional recordings were made at a 10° starboard aspect. Source levels were derived with a spherical propagation (surface-affected) or a modified Lloyd's mirror model to account for interference from surface reflections (surface-corrected). Ship source depths were estimated from spectral differences between measurements at different beam aspects. Results were exemplified with a 4870 and a 10 036 twenty-foot equivalent unit container ship at 40%-56% and 87% of service speeds, respectively. For the larger ship, opportunistic ANSI/ISO broadband levels were 195 (surface-affected) and 209 (surface-corrected) dB re 1 μPa 2 1 m. Directionality at a propeller blade rate of 8 Hz exhibited asymmetries in stern-bow (<6 dB) and port-starboard (<9 dB) direction. Previously reported broadband levels at 10° aspect from McKenna, Ross, Wiggins, and Hildebrand [(2012b). J. Acoust. Soc. Am. 131, 92-103] may be ∼12 dB lower than respective surface-affected ANSI/ISO standard derived levels.

  8. Noise from wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Fegeant, Olivier [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Building Sciences

    2002-02-01

    A rapid growth of installed wind power capacity is expected in the next few years. However, the siting of wind turbines on a large scale raises concerns about their environmental impact, notably with respect to noise. To this end, variable speed wind turbines offer a promising solution for applications in densely populated areas like the European countries, as this design would enable an efficient utilisation of the masking effect due to ambient noise. In rural and recreational areas where wind turbines are sited, the ambient noise originates from the action of wind on the vegetation and about the listener's ear (pseudo-noise). It shows a wind speed dependence similar to that of the noise from a variable speed wind turbine and can therefore mask the latter for a wide range of conditions. However, a problem inherent to the design of these machines is their proclivity to pure tone generation, because of the enhanced difficulty of avoiding structural resonances in the mechanical parts. Pure tones are deemed highly annoying and are severely regulated by most noise policies. In relation to this problem, the vibration transmission of structure-borne sound to the tower of the turbine is investigated, in particular when the tower is stiffened at its upper end. Furthermore, since noise annoyance due to wind turbine is mostly a masking issue, the wind-related sources of ambient noise are studied and their masking potentials assessed. With this aim, prediction models for wind-induced vegetation noise and pseudo-noise have been developed. Finally, closely related to the effect of masking, is the difficulty, regularly encountered by local authorities and wind farm developers, to measure noise immission from wind turbines. A new measurement technique has thus been developed in the course of this work. Through improving the signal-to-noise ratio between wind turbine noise and ambient noise, the new technique yields more accurate measurement results.

  9. Mapping Urban Environmental Noise Using Smartphones

    Directory of Open Access Journals (Sweden)

    Jinbo Zuo

    2016-10-01

    Full Text Available Noise mapping is an effective method of visualizing and accessing noise pollution. In this paper, a noise-mapping method based on smartphones to effectively and easily measure environmental noise is proposed. By using this method, a noise map of an entire area can be created using limited measurement data. To achieve the measurement with certain precision, a set of methods was designed to calibrate the smartphones. Measuring noise with mobile phones is different from the traditional static observations. The users may be moving at any time. Therefore, a method of attaching an additional microphone with a windscreen is proposed to reduce the wind effect. However, covering an entire area is impossible. Therefore, an interpolation method is needed to achieve full coverage of the area. To reduce the influence of spatial heterogeneity and improve the precision of noise mapping, a region-based noise-mapping method is proposed in this paper, which is based on the distribution of noise in different region types tagged by volunteers, to interpolate and combine them to create a noise map. To validate the effect of the method, a comparison of the interpolation results was made to analyse our method and the ordinary Kriging method. The result shows that our method is more accurate in reflecting the local distribution of noise and has better interpolation precision. We believe that the proposed noise-mapping method is a feasible and low-cost noise-mapping solution.

  10. Noise Pollution and Health Effects

    Directory of Open Access Journals (Sweden)

    Geravandi

    2015-01-01

    Full Text Available Background Noise pollution is of particular importance due to the physical and psychological effects on humans. Noise is a stressor that affects the autonomic nervous system and the endocrine system. Noise is also a threat to marine and terrestrial ecosystems. Health risks from noise are correlated with road traffic. In other words, noise health effects are the health consequences of elevated sound levels. Objectives This study aims to determine the effect of noise pollution (near roadways on health issues in Ahvaz, Iran. Materials and Methods In this cross-sectional study, equivalent sound pressure level were measured by sound level meters TES-1353 in 75 locations around 4 roadways, which had a high load of traffic in Ahvaz City during day time. During the study, 820 measurements were recorded at measuring stations, for 7 days per week with 1-hour interval between each measurement. Statistical analysis was carried out by SPSS software. Results According to the research findings, the equivalent sound pressure levels in all stations were 76.28 ± 3.12 dB (Mean ± SD. According to sound measurements and the survey questionnaire, noise pollution is higher than EPA (US Environmental Protection Agency and Iran standard level. Based on result of this study the worst noise health effects were the nervousness and sleep quality during 2012. Conclusions According to the results of this study, with increasing load of traffic, there is an increasing need for proper consideration plans to control noise pollution and prevent its effects.

  11. Bayesian inverse problems in measure spaces with application to Burgers and Hamilton–Jacobi equations with white noise forcing

    International Nuclear Information System (INIS)

    Hoang, Viet Ha

    2012-01-01

    This paper formulates Bayesian inverse problems for inference in a topological measure space given noisy observations. Conditions for the validity of the Bayes’ formula and the well posedness of the posterior measure are studied. The abstract theory is then applied to Burgers and Hamilton–Jacobi equations on a semi-infinite time interval with forcing functions which are white noise in time. Inference is made on the white noise forcing, assuming the Wiener measure as the prior. (paper)

  12. Measurements and analysis of neutron and gamma noise in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van; Kleiss, E.B.J.

    1985-01-01

    Neutron and gamma sensitive collectrons (self-powered detectors) have been designed for incore noise measurements in BWRs. A so-called twin-type has been developed for measurements of two-phase flow characteristics and detailed axial velocity distributions. Construction aspects of the twin detectors are discussed. An analysis is presented of the response of both detector types to incore parametric fluctuations. This analysis is based on detector response functions which provide an insight into the 'field of view' of the two types. The results are supported by experimental verifications; it is shown that incore gamma detectors provide useful additional information about two-phase flow in a BWR. (author)

  13. Characterization of the activity of ultrasound emitted in a perpendicular liquid flow using Particle Image Velocimetry (PIV) and electrochemical mass transfer measurements.

    Science.gov (United States)

    Barthès, Magali; Mazue, Gerald; Bonnet, Dimitri; Viennet, Remy; Hihn, Jean-Yves; Bailly, Yannick

    2015-05-01

    The present work is dedicated to the study of the interactions between a liquid circulation and a perpendicular acoustic wave propagation. A specific experimental setup was designed to study one transducer operating at 20 kHz, with the help of electrochemical mass transfer measurements combined with Particle Image Velocimetry (PIV) determination. Electrodes were located on the wall opposite to the acoustic emission. Experiments were performed for various Reynolds numbers: from 0 to 21700 (different liquid flow rates and viscosities). Both PIV and electrochemical measurements methods were found to be relevant, and had delivered complementary information. Even if PIV showed that the plume due to streaming was highly deflected by the additional flow, electrochemical measurements showed that there was still an activity, higher than in silent conditions, on the wall facing the transducer. Thus the ultrasound contribution remained noticeable on the surface opposite to the transducer even for a disturbed hydrodynamic environment due to the presence of a liquid circulation perpendicular to the wave propagation. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Noise frame duration, masking potency and whiteness of temporal noise.

    Science.gov (United States)

    Kukkonen, Heljä; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antti

    2002-09-01

    Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. Contrast energy thresholds (E(th)) were measured for flicker at 1.25 to 20 Hz in strong, purely temporal (spatially uniform), additive, external noise. The masking power of white external noise, characterized by its spectral density at zero frequency N0, increases with the duration of the noise frame. For short noise frame durations, E(th) increased in direct proportion to N0, keeping the nominal signal-to-noise ratio [SNR = (E(th)/N0)(0.5)] constant at threshold. The masking effect thus increased with the duration of the noise frame and the noise mimicked white noise. When noise frame duration and N0 increased further, the nominal SNR at threshold started to decrease, indicating that noise no longer mimicked white noise. The minimum number of noise frames per flicker cycle needed to mimic white noise decreased with increasing flicker frequency from 8.3 at 1.25 Hz to 1.6 at 20 Hz. The critical high-frequency cutoff of detection-limiting temporal noise in terms of noise frames per signal cycle depends on the temporal frequency of the signal. This is opposite to the situation in the spatial domain and must be taken into consideration when temporal signals are masked with temporal noise.

  15. Measures of the zero power nuclear reactor's kinetic parameters with application of noise analysis

    International Nuclear Information System (INIS)

    Martins, F.R.

    1992-01-01

    The purpose of this work was to establish an experimental technique based on noise analysis for measuring the ratio of kinetic parameters β/ Λ and the power of the Zero Power Nuclear Reactor IPEN-MB 01. A through study of the microscopic and macroscopic noise analysis techniques has been carried out. The Langevin technique and the point kinetic model were chosen to describe the stochastic phenomena that occur in the zero power reactor. Measurements have been made using two compensated ionization chambers localized in the water reflector at symmetric positions in order to minimize spatial effects on the neutron flux fluctuation. Power calibrations based on the low frequency plateau of the cross-power spectral density has also been carried out. (author)

  16. Evaluation of Noise Exposure Secondary to Wind Noise in Cyclists.

    Science.gov (United States)

    Seidman, Michael D; Wertz, Anna G; Smith, Matthew M; Jacob, Steve; Ahsan, Syed F

    2017-11-01

    Objective Determine if the noise levels of wind exposure experienced by cyclists reach levels that could contribute to noise-induced hearing loss. Study Design Industrial lab research. Setting Industrial wind tunnel. Subjects and Methods A commercial-grade electric wind tunnel was used to simulate different speeds encountered by a cyclist. A single cyclist was used during the simulation for audiometric measurements. Microphones attached near the ears of the cyclist were used to measure the sound (dB sound pressure level) experienced by the cyclist. Loudness levels were measured with the head positioned at 15-degree increments from 0 degrees to 180 degrees relative to the oncoming wind at different speeds (10-60 mph). Results Wind noise ranged from 84.9 dB at 10 mph and increased proportionally with speed to a maximum of 120.3 dB at 60 mph. The maximum of 120.3 dB was measured at the downwind ear when the ear was 90 degrees away from the wind. Conclusions Wind noise experienced by a cyclist is proportional to the speed and the directionality of the wind current. Turbulent air flow patterns are observed that contribute to increased sound exposure in the downwind ear. Consideration of ear deflection equipment without compromising sound awareness for cyclists during prolonged rides is advised to avoid potential noise trauma. Future research is warranted and can include long-term studies including dosimetry measures of the sound and yearly pre- and postexposure audiograms of cyclists to detect if any hearing loss occurs with long-term cycling.

  17. The recommendations of the noise working group

    International Nuclear Information System (INIS)

    Legerton, M.L.

    1997-01-01

    In 1993 the DTI set up a Working Group to define a framework which can be used to measure and rate the noise from wind turbines. The final report of the Noise Working Group is now available for publication. The advice on the setting of noise limits for wind farms is largely unaltered from the preliminary recommendations presented at the 17th BWEA Annual Conference [1]. This paper recaps on those recommendations and provides additional information on the measurement procedures to be used with the recommendations on noise limits. The paper describes the measurement of the existing background noise climate on which the limits are based and the procedure to be used for the measurement of turbine noise levels in the investigation of complaints. The noise limits are rated noise levels in that they can include a penalty for tones present in the noise. The level of penalty depends upon the audibility of the tone and measurement procedure for determining audibility and the associated penalty system are also described. (author)

  18. Fabrication and testing of an electrochemical microcell for in situ soft X-ray microspectroscopy measurements

    Science.gov (United States)

    Gianoncelli, A.; Kaulich, B.; Kiskinova, M.; Mele, C.; Prasciolu, M.; Sgura, I.; Bozzini, B.

    2013-03-01

    In this paper we report on the fabrication and testing of a novel concept of electrochemical microcell for in-situ soft X-ray microspectroscopy in transmission. The microcell, fabricated by electron-beam lithography, implements an improved electrode design, with optimal current density distribution and minimised ohmic drop, allowing the same three-electrode electrochemical control achievable with traditional cells. Moreover standard electroanalytical measurements, such as cyclic voltammetry, can be routinely performed. As far as the electrolyte is concerned, we selected a room-temperature ionic-liquid. Some of the materials belonging to this class, in addition to a broad range of outstanding electrochemical properties, feature two highlights that are crucial for in situ, soft X-ray transmission work: spinnability, enabling accurate thickness control, and stability to UHV, allowing operation of an open cell in the analysis chamber vacuum (10-6 mbar). The cell can, of course, be used also with non-vacuum stable electrolytes in the sealed version developed in previous work in our group. In this study, the microcell designed, fabricated and tested in situ by applying an anodic polarisation to a Au electrode and following the formation of a distribution of corrosion features. This specific material combination presented in this work does not limit the cell concept, that can implement any electrodic material grown by lithography, any liquid electrolyte and any spinnable solid electrolyte.

  19. J-85 jet engine noise measured in the ONERA S1 wind tunnel and extrapolated to far field

    Science.gov (United States)

    Soderman, Paul T.; Julienne, Alain; Atencio, Adolph, Jr.

    1991-01-01

    Noise from a J-85 turbojet with a conical, convergent nozzle was measured in simulated flight in the ONERA S1 Wind Tunnel. Data are presented for several flight speeds up to 130 m/sec and for radiation angles of 40 to 160 degrees relative to the upstream direction. The jet was operated with subsonic and sonic exhaust speeds. A moving microphone on a 2 m sideline was used to survey the radiated sound field in the acoustically treated, closed test section. The data were extrapolated to a 122 m sideline by means of a multiple-sideline source-location method, which was used to identify the acoustic source regions, directivity patterns, and near field effects. The source-location method is described along with its advantages and disadvantages. Results indicate that the effects of simulated flight on J-85 noise are significant. At the maximum forward speed of 130 m/sec, the peak overall sound levels in the aft quadrant were attentuated approximately 10 dB relative to sound levels of the engine operated statically. As expected, the simulated flight and static data tended to merge in the forward quadrant as the radiation angle approached 40 degrees. There is evidence that internal engine or shock noise was important in the forward quadrant. The data are compared with published predictions for flight effects on pure jet noise and internal engine noise. A new empirical prediction is presented that relates the variation of internally generated engine noise or broadband shock noise to forward speed. Measured near field noise extrapolated to far field agrees reasonably well with data from similar engines tested statically outdoors, in flyover, in a wind tunnel, and on the Bertin Aerotrain. Anomalies in the results for the forward quadrant and for angles above 140 degrees are discussed. The multiple-sideline method proved to be cumbersome in this application, and it did not resolve all of the uncertainties associated with measurements of jet noise close to the jet. The

  20. Low voltage excess noise and shot noise in YBCO bicrystal junctions

    DEFF Research Database (Denmark)

    Constantinian, K.Y.; Ovsyannikov, G.A.; Borisenko, I.V.

    2002-01-01

    The spectral density of background noise emitted by symmetric bicrystal YBaCuO Josephson junctions on sapphire substrates have been measured by a low noise cooled HEMT amplifier for bias voltages up to V approximate to 50 mV. At relatively low voltages V noise rise has been...... registered. At large bias voltages V > 30 mV a clear dependence of noise power. exactly coinciding to the asymptote of the Schottky shot noise function, has been observed for the first time. Experimental results are discussed in terms of multiple Andreev reflections which may take place in d...

  1. Inhibitor selection for internal corrosion control of pipelines: experience with field monitoring and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Demoz, A.; Michaelian, K.H.; Donini, J. [Natural Resources Canada, CANMET Western Research Centre, Devon, AB (Canada); Papavinasam, S.; Revie, R.W. [Natural Resources Canada, CANMET Materials Technology Laboratory, Ottawa, ON (Canada)

    1999-07-01

    A loop of pipe consisting of pipe segments of 3 inches, 6 inches and 10 inches that could take the full flow of a production well was designed, constructed and put in-line close to a wellhead. The loop was able to simulate multiphase pipelines and had ports for coupons, some of which were used for electrochemical monitoring. Various techniques including electrochemical impedance spectroscopy (EIS), electrochemical noise (ECN), and linear polarization resistance (LPR) were employed, all of which gave corrosion rates that depended on the position of the coupons inside the loop (increasing from top to bottom, reflecting the media and flow to which coupons were exposed in a multiphase producing well). Results indicated that the general corrosion rates obtained were dependent on the method used for measurement, but following the relative trend of LPR>weight loss>EIS>ECN. 20 refs., 8 figs.

  2. Detailed Electrochemical Characterisation of Large SOFC Stacks

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Hjelm, Johan; Barfod, R.

    2012-01-01

    application of advanced methods for detailed electrochemical characterisation during operation. An operating stack is subject to steep compositional gradients in the gaseous reactant streams, and significant temperature gradients across each cell and across the stack, which makes it a complex system...... Fuel Cell A/S was characterised in detail using electrochemical impedance spectroscopy. An investigation of the optimal geometrical placement of the current probes and voltage probes was carried out in order to minimise measurement errors caused by stray impedances. Unwanted stray impedances...... are particularly problematic at high frequencies. Stray impedances may be caused by mutual inductance and stray capacitance in the geometrical set-up and do not describe the fuel cell. Three different stack geometries were investigated by electrochemical impedance spectroscopy. Impedance measurements were carried...

  3. Dynamic strain measurement system with fiber Bragg gratings and noise mitigation techniques

    International Nuclear Information System (INIS)

    Tosi, D; Olivero, M; Perrone, G

    2009-01-01

    A low-cost fiber Bragg grating (FBG) vibrometer specifically suited for structural monitoring and aimed at the detection of low-amplitude vibrations is presented. The optical system exploits an intensity modulation principle of operation, while signal processing techniques are used to complement the transducer to improve the performances: a recursive least-squares adaptive filter improves the noise power mitigation by 14 dB, and an efficient spectral estimator permits operating spectral analysis even under high noise conditions. With these methods, a strain sensitivity of 5.6 nε has been achieved in the ±60 µε range. Experimental assessment tests carried out in typical structural monitoring contexts have demonstrated that the developed sensor is well suited to measure mechanical perturbations of different structures

  4. Source-driven noise analysis measurements with neptunium metal reflected by high enriched uranium

    International Nuclear Information System (INIS)

    Valentine, Timothy E.; Mattingly, John K.

    2003-01-01

    Subcritical noise analysis measurements have been performed with neptunium ( 237 Np) sphere reflected by highly enriched uranium. These measurements were performed at the Los Alamos Critical Experiment Facility in December 2002 to provide an estimate of the subcriticality of 237 Np reflected by various amounts of high-enriched uranium. This paper provides a description of the measurements and presents some preliminary results of the analysis of the measurements. The measured and calculated spectral ratios differ by 15% whereas the 'interpreted' and calculated k eff values differ by approximately 1%. (author)

  5. The measurement of phosphorus in low alloy steels by electrochemical methods

    International Nuclear Information System (INIS)

    Rahier, A.; Campsteyn, A.; Verheyen, E.; Verpoucke, G.

    2008-01-01

    The oscillo-polarographic method reported by Chen for the determination of phosphorus in silicates, iron ores, carbonates and tea leaves has been thoroughly studied and enhanced in view of the determination of P in various steels. Together with a carefully selected sample dissolution method, the chromatographic separation reported by Hanada et al. for eliminating the matrix has also been examined. The results of these investigations allowed finding out a path towards the successful electrochemical measurement of P in low alloy ferritic steels without eliminating the matrix. The limit of detection is 5.2 micro gram -1 in the metal. The precision ranges between 5 and 15 % relative to the mean measured values. The finely tuned method has been successfully validated using five NIST standard steels. The chromatographic method remains an option for addressing other metals in the future, should they contain unacceptable levels of possibly interfering elements.. Detailed experimental procedures are given.

  6. The measurement of phosphorus in low alloy steels by electrochemical methods

    Energy Technology Data Exchange (ETDEWEB)

    Rahier, A.; Campsteyn, A.; Verheyen, E.; Verpoucke, G.

    2008-08-15

    The oscillo-polarographic method reported by Chen for the determination of phosphorus in silicates, iron ores, carbonates and tea leaves has been thoroughly studied and enhanced in view of the determination of P in various steels. Together with a carefully selected sample dissolution method, the chromatographic separation reported by Hanada et al. for eliminating the matrix has also been examined. The results of these investigations allowed finding out a path towards the successful electrochemical measurement of P in low alloy ferritic steels without eliminating the matrix. The limit of detection is 5.2 micro gram{sup -1} in the metal. The precision ranges between 5 and 15 % relative to the mean measured values. The finely tuned method has been successfully validated using five NIST standard steels. The chromatographic method remains an option for addressing other metals in the future, should they contain unacceptable levels of possibly interfering elements.. Detailed experimental procedures are given.

  7. Using the coolant temperature noise for measuring the flow rate in the RBMK technological channels

    International Nuclear Information System (INIS)

    Selivanov, V.M.; Karlov, N.P.; Martynov, A.D.; Prostyakov, V.V.; Lysikov, B.V.; Kuznetsov, B.A.; Pallagi, D.; Khorani, Sh.; Khargitai, T.; Tezher, Sh.

    1983-01-01

    The problems are considered connected with the possibility of using thermometric correlation method to measure the coolant flow rate in the RBMK reactor technological channels. The main attention is paid to the study of the physical nature of the coolant temperature pulsations and to estimation of the effect of parameters of the primary thermaelectrical converter (TEC) on the results of measurements. In the process of reactor inspections made using the thermometric correlation flowmeter of a special design, the temperature noise distribution in the points of flow rate measurement is studied, the noise intensity and physical nature are determined, as well as the effect of different TEC parameters (TEC inertia and base distance between them) on the measurement accuracy. On the basis of the analysis of the effect on the results of the TEC thermal inertia measured value divergence, tausub(α) and transport time, tau sub(T), a conclusion is made on the necessity of choosing the base distance between TEC with tausub(T)>tausub(d)

  8. State-of-the-Art Review on Sustainable Design and Construction of Quieter Pavements—Part 1: Traffic Noise Measurement and Abatement Techniques

    Directory of Open Access Journals (Sweden)

    MD Ohiduzzaman

    2016-08-01

    Full Text Available Noise pollution due to highway traffic has drawn the attention of transportation agencies worldwide. Noise pollution is an irritant to residents, especially in urban areas near roads with high traffic volume. In addition to its adverse effects on the quality of life, traffic noise can induce stress that could lead to sleep disturbance and anxiety. Traditionally, noise barrier walls have been used for highways to mitigate traffic noise. However, using barrier walls as a noise abatement measure has proven to be very expensive. In addition to the cost, noise barrier walls are not always effective because they must break the line of sight to work properly, which is not always possible in case of intersections or driveways. Therefore, researchers especially from Europe and USA have been very proactive to reduce the noise at source. A number of research studies show traffic noise can be reduced by using an alternative surface type or changing texture of the pavement while complying with other requirements of sustainability, i.e., safety, structural durability, construction and maintenance costs. This paper presents a comprehensive review of the research conducted on this subject. A review of the tire-pavement noise generation and amplification mechanism, various traffic noise measurement methods and correlation among these methods, in addition to the abatement techniques used by various agencies to reduce pavement noise, is also presented.

  9. Electrochemically assisted fast-atom-bombardment mass spectrometry

    International Nuclear Information System (INIS)

    Phillips, L.R.

    1988-01-01

    The hybridization of electrochemistry and fast atom bombardment (FAB) mass spectrometry (MS) creates a new hyphenated technique, referred to as electrochemically assisted FAB (EFAB) MS, which improves the applicability of FAB MS in selectivity and extends the range of compounds to include low polarity molecules, and also reduces mass spectral complications due to matrix-related artifacts. FAB MS has proven to be indispensable in analysis of samples that are otherwise too intractable for conventional MS, such as peptides, oligosaccharides, and oligonucleotides, due to low volatility and ready thermal degradation. There are limits on its applicability, however, in that it works best with samples that are already ionic, or predisposed to become so by simple proton transfer to or from the matrix. A wide range of chemical substances can be ionized/analyzed by electrochemical methods. Therefore, a possible approach towards improving applicability of FAB MS is through its hybridization with electrochemistry. Samples are activated by electrolysis, carried out directly in the sample matrix through use of a modified FAB sample probe which was constructed containing a small electrolytic cell on the tip. In operation, one electrode is held at normal sample-probe/ion-source voltage, while the other electrode can be continuously varied ±15 volts to create electrochemical potentials. Several chemical substances, known to be unresponsive to FAB MS, have been examined by EFAB MS. Resultant spectra generally show a dramatic increases in signal/chemical noise ratio of structurally significant ions when compared to normal FAB spectra

  10. Noise in restaurants: levels and mathematical model.

    Science.gov (United States)

    To, Wai Ming; Chung, Andy

    2014-01-01

    Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (L(eq,1-h)) was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  11. Noise in restaurants: Levels and mathematical model

    Directory of Open Access Journals (Sweden)

    Wai Ming To

    2014-01-01

    Full Text Available Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (Leq,1-h was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  12. Post commissioning noise study

    International Nuclear Information System (INIS)

    Heraud, P.

    2008-01-01

    This presentation described a wind farm post-commissioning study conducted at a wind farm owned by Helimax Energy Inc. The farm was located in a partly-forested, partly cultivated region in Quebec that featured gently rolling hills. Over 600 dwellings were located within 2 km of the wind farm, and 44 dwellings were within the wind farm's boundaries. The noise impact assessments were conducted at various points near the wind farm. The wind farm was designed using an International Standards Organization (ISO) noise propagation model and a 40 dBA to provide adequate setbacks. The study was conducted using 10 days of continuous measurements at selected points of a wind farm. Points of reception included points from 650 m to 800 m. Noise over 2 km was not thought to be contributed by the wind turbine. The nearest dwelling was 512 m from one of the farm's wind turbines. The study also considered ground factor, temperature, relative humidity, and the height of the receptors. Quebec noise level limits are 40 dBA at night, and 45 dBA during the day. Noise level limits are independent of wind speed. Measured noise contributions over 40 dBA were not observed during the measurement program. The wind turbines were only audible for 1 night out of the 30 night study period. It was concluded that the ISO noise propagation model is a reliable tool for conducting noise impact assessments. tabs., figs

  13. Noise properties of Hilbert transform evaluation

    International Nuclear Information System (INIS)

    Pavliček, Pavel; Svak, Vojtěch

    2015-01-01

    The Hilbert transform is a standard method for the calculation of the envelope and phase of a modulated signal in optical measurement methods. Usually, the intensity of light is converted into an electric signal at a detector. Therefore the actual spatially or temporally sampled signal is always affected by noise. Because the noise values of individual samples are independent, the noise can be considered as white. If the envelope and phase are calculated from the noised signal, they will also be affected by the noise. We calculate the variance and spectral density of both the envelope noise and the phase noise. We determine which parameters influence the variance and spectral density of both the envelope noise and the phase noise. Finally, we determine the influence of the noise on the measurement uncertainty in white-light interferometry and fringe-pattern analysis. (paper)

  14. Passive acoustic measurement of bedload grain size distribution using self-generated noise

    Directory of Open Access Journals (Sweden)

    T. Petrut

    2018-01-01

    Full Text Available Monitoring sediment transport processes in rivers is of particular interest to engineers and scientists to assess the stability of rivers and hydraulic structures. Various methods for sediment transport process description were proposed using conventional or surrogate measurement techniques. This paper addresses the topic of the passive acoustic monitoring of bedload transport in rivers and especially the estimation of the bedload grain size distribution from self-generated noise. It discusses the feasibility of linking the acoustic signal spectrum shape to bedload grain sizes involved in elastic impacts with the river bed treated as a massive slab. Bedload grain size distribution is estimated by a regularized algebraic inversion scheme fed with the power spectrum density of river noise estimated from one hydrophone. The inversion methodology relies upon a physical model that predicts the acoustic field generated by the collision between rigid bodies. Here we proposed an analytic model of the acoustic energy spectrum generated by the impacts between a sphere and a slab. The proposed model computes the power spectral density of bedload noise using a linear system of analytic energy spectra weighted by the grain size distribution. The algebraic system of equations is then solved by least square optimization and solution regularization methods. The result of inversion leads directly to the estimation of the bedload grain size distribution. The inversion method was applied to real acoustic data from passive acoustics experiments realized on the Isère River, in France. The inversion of in situ measured spectra reveals good estimations of grain size distribution, fairly close to what was estimated by physical sampling instruments. These results illustrate the potential of the hydrophone technique to be used as a standalone method that could ensure high spatial and temporal resolution measurements for sediment transport in rivers.

  15. Passive acoustic measurement of bedload grain size distribution using self-generated noise

    Science.gov (United States)

    Petrut, Teodor; Geay, Thomas; Gervaise, Cédric; Belleudy, Philippe; Zanker, Sebastien

    2018-01-01

    Monitoring sediment transport processes in rivers is of particular interest to engineers and scientists to assess the stability of rivers and hydraulic structures. Various methods for sediment transport process description were proposed using conventional or surrogate measurement techniques. This paper addresses the topic of the passive acoustic monitoring of bedload transport in rivers and especially the estimation of the bedload grain size distribution from self-generated noise. It discusses the feasibility of linking the acoustic signal spectrum shape to bedload grain sizes involved in elastic impacts with the river bed treated as a massive slab. Bedload grain size distribution is estimated by a regularized algebraic inversion scheme fed with the power spectrum density of river noise estimated from one hydrophone. The inversion methodology relies upon a physical model that predicts the acoustic field generated by the collision between rigid bodies. Here we proposed an analytic model of the acoustic energy spectrum generated by the impacts between a sphere and a slab. The proposed model computes the power spectral density of bedload noise using a linear system of analytic energy spectra weighted by the grain size distribution. The algebraic system of equations is then solved by least square optimization and solution regularization methods. The result of inversion leads directly to the estimation of the bedload grain size distribution. The inversion method was applied to real acoustic data from passive acoustics experiments realized on the Isère River, in France. The inversion of in situ measured spectra reveals good estimations of grain size distribution, fairly close to what was estimated by physical sampling instruments. These results illustrate the potential of the hydrophone technique to be used as a standalone method that could ensure high spatial and temporal resolution measurements for sediment transport in rivers.

  16. Piribedil affects dopamine turnover in cochleas stimulated by white noise.

    Science.gov (United States)

    Gil-Loyzaga, P; Vicente-Torres, M A; Fernández-Mateos, P; Arce, A; Esquifino, A

    1994-09-01

    The presence of dopamine (DA) within the cochlea has been previously reported, indicating that its turnover increases under noise stimulation. In the present report, piribedil, a dopaminergic D2 agonist, was used in order to provide evidence of the activity of D2 receptors in the turnover of DA under noise stimulation. Long-Evans rats were intraperitoneally injected with distilled water or with a solution of piribedil one hour previously to either noise or silence exposure. Noise stimulation was performed in an anechoic chamber at 70, 90 or 110 dB SPL for one hour. The animals were then sacrificed and the cochlear contents of DA and its metabolites dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) were quantified by HPLC with electrochemical detection. The administration of piribedil to animals kept in silence did not modify the cochlear DA, DOPAC and HVA content. Noise stimulation resulted in a decrease of the cochlear DA content and an increase of the cochlear DOPAC and HVA contents in vehicle treated animals. The administration of piribedil resulted in a blockade of this noise induced cochlear DA turnover. These results suggest that piribedil stimulates cochlear D2 receptors controlling the cochlear DA release. Piribedil action on D2 receptors could explain the improvement observed in some cochleo-vestibular diseases signs after piribedil treatment.

  17. The effects of toluene plus noise on hearing thresholds: an evaluation based on repeated measurements in the German printing industry.

    Science.gov (United States)

    Schäper, Michael; Seeber, Andreas; van Thriel, Christoph

    2008-01-01

    The ototoxicity of occupational exposure to toluene plus noise was investigated in a longitudinal study in rotogravure printing and existing findings in the literature were evaluated. The study comprised four repeated examinations during 5 years and started with 333 male workers. Lifetime weighted average exposures (LWAE) to toluene and noise were determined from individual work histories and historic recordings; recent individual exposures were measured 10 times during the study (toluene, active sampling; noise, stationary measurements). Auditory thresholds were measured with pure tone audiometry at 0.125, 0.25, 0.5, 0.75, 1, 2, 3, 4, 6, 8, 12 kHz. Mean LWAE exposures to toluene and noise were 45+/-17 ppm plus 82+/-7 dB(A) for high toluene exposed and 10+/-7 ppm plus 82+/-4 dB(A) for low toluene exposed subjects, mean current exposures were 26+/-20 ppm plus 81+/-4 dB(A) and 3+/-3 ppm plus 82+/-4 dB(A). Mean exposure duration was 21.3+/-6.5 years for long exposed and 5.9+/-2.2 years for short exposed subjects. Repeated measurement analyses of variance did not reveal effects of toluene intensity, exposure duration and interactions between toluene intensity and noise intensity. Noise intensity [79+/-3 dB(A) vs. 84+/-1 dB(A)] was significant for auditory thresholds. A case concept utilising developments of individual auditory thresholds did not reveal significant toluene effects. Logistic models including age, exposure duration, toluene in ambient air, current noise and either hippuric acid or ortho-cresol (o-cresol) found only age to be significant for elevated OR of high frequency hearing loss. Due to missing toluene effects, it was concluded that the threshold level for developing hearing loss as a result of occupational exposure to toluene plus noise might be above the current limit of 50 ppm toluene.

  18. Electrical, electrochemical and isotopic exchange measurements on lanthanum gallate based ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Bronin, D.I.; Gorelov, V.P. [RAS, Ekaterinburg (Russian Federation). Inst. of High-Temperature Electrochemistry]|[Max-Planck-Institut fuer Festkoerperforschung, Stuttgart (Germany); Kuzin, B.L.; Kurumchin, E.Kh.; Vdovin, G.K.; Sokolova, Ju.V.; Beresnev, S.M. [RAS, Ekaterinburg (Russian Federation). Inst. of High-Temperature Electrochemistry; Keppeler, M.; Naefe, H.; Aldinger, F. [Max-Planck-Institut fuer Festkoerperforschung, Stuttgart (Germany)

    2000-07-01

    The solubility limits of Sr and Mg in La{sub 1-x}Sr{sub x}Ga{sub 1-y}Mg{sub y}O{sub 3-{delta}} (LSGM) and the electrical conductivity of LSGM and La{sub 1-x}Sr{sub x}Ga{sub 1-y-z}Mg{sub y}Co{sub z}O{sub 3-{delta}} (LSGMC) were studied. By electrochemical and isotopic exchange measurements on both LSGM material and on an LSGM pellet whose surface was modified by Co-doping, it was shown that the oxygen exchange rate between the solids and the surrounding gas phase is much higher in the case of the modified electrolyte material. A single fuel cell with an LSGM electrolyte was constructed and tested. (orig.)

  19. Measuring test mass acceleration noise in space-based gravitational wave astronomy

    Science.gov (United States)

    Congedo, Giuseppe

    2015-03-01

    The basic constituent of interferometric gravitational wave detectors—the test-mass-to-test-mass interferometric link—behaves as a differential dynamometer measuring effective differential forces, comprising an integrated measure of gravity curvature, inertial effects, as well as nongravitational spurious forces. This last contribution is going to be characterized by the LISA Pathfinder mission, a technology precursor of future space-borne detectors like eLISA. Changing the perspective from displacement to acceleration can benefit the data analysis of LISA Pathfinder and future detectors. The response in differential acceleration to gravitational waves is derived for a space-based detector's interferometric link. The acceleration formalism can also be integrated into time delay interferometry by building up the unequal-arm Michelson differential acceleration combination. The differential acceleration is nominally insensitive to the system's free evolution dominating the slow displacement dynamics of low-frequency detectors. Working with acceleration also provides an effective way to subtract measured signals acting as systematics, including the actuation forces. Because of the strong similarity with the equations of motion, the optimal subtraction of systematic signals, known within some amplitude and time shift, with the focus on measuring the noise provides an effective way to solve the problem and marginalize over nuisance parameters. The F statistic, in widespread use throughout the gravitation waves community, is included in the method and suitably generalized to marginalize over linear parameters and noise at the same time. The method is applied to LPF simulator data and, thanks to its generality, can also be applied to the data reduction and analysis of future gravitational wave detectors.

  20. Noise characterization of oil and gas operations.

    Science.gov (United States)

    Radtke, Cameron; Autenrieth, Daniel A; Lipsey, Tiffany; Brazile, William J

    2017-08-01

    In cooperation with The Colorado Oil and Gas Conservation Commission, researchers at Colorado State University performed area noise monitoring at 23 oil and gas sites throughout Northern Colorado. The goals of this study were to: (1) measure and compare the noise levels for the different phases of oil and gas development sites; (2) evaluate the effectiveness of noise barriers; and (3) determine if noise levels exceeded the Colorado Oil and Gas Conservation Commission noise limits. The four phases of oil and gas development include drilling, hydraulic fracturing, completion and production. Noise measurements were collected using the A- and C-weighted sound scales. Octave band analysis was also performed to characterize the frequency spectra of the noise measurements.  Noise measurements were collected using noise dosimeters and a hand-held sound-level meter at specified distances from the development sites in each cardinal direction. At 350 ft (107 m), drilling, hydraulic fracturing, and completion sites without noise barriers exceeded the maximum permissible noise levels for residential and commercial zones (55 dBA and 60 dBA, respectively). In addition, drilling and hydraulic fracturing sites with noise barriers exceeded the maximum permissible noise level for residential zones (55 dBA). However, during drilling, hydraulic fracturing, and completion operations, oil producers are allowed an exception to the noise permissible limits in that they only must comply with the industrial noise limit (80 dBA). It is stated in Rule 604.c.(2)A. that: "Operations involving pipeline or gas facility installation or maintenance, the use of a drilling rig, completion rig, workover rig, or stimulation is subject to the maximum permissible noise levels for industrial zones (80dBA)." [8] Production sites were within the Colorado Oil and Gas Conservation Commission permissible noise level criteria for all zones. At 350 ft (107 m) from the noise source, all drilling

  1. Measurement and modelling of noise emission of road vehicles for use in prediction models

    Energy Technology Data Exchange (ETDEWEB)

    Jonasson, H.G.

    2000-07-01

    The road vehicle as sound source has been studied within a wide frequency range. Well defined measurements have been carried out on moving and stationary vehicles. Measurement results have been checked against theoretical simulations. A Nordtest measurement method to obtain input data for prediction methods has been proposed and tested in four different countries. The effective sound source of a car has its centre close to the nearest wheels. For trucks this centre seems to be closer to the centre of the car. The vehicle as sound source is directional both in the vertical and the horizontal plane. The difference between SEL and L{sub pFmax} during a pass-by varies with frequency. At low frequencies interference effects between correlated sources may be the problem. At high frequencies the directivity of tyre/road noise affects the result. The time when L{sub pFmax} is obtained varies with frequency. Thus traditional maximum measurements are not suitable for frequency band applications. The measurements support the fact that the tyre/road noise source is very low. Measurements on a stationary vehicle indicate that the engine source is also very low. Engine noise is screened by the body of the car. The ground attenuation, also at short distances, will be significant whenever we use low microphone positions and have some 'soft' ground in between. Unless all measurements are restricted to propagation over 'hard' surfaces only it is necessary to use rather high microphone positions. The Nordtest method proposed will yield a reproducibility standard deviation of 1-3 dB depending on frequency. High frequencies are more accurate. In order to get accurate results at low frequencies large numbers of vehicles are required. To determine the sound power level from pass-by measurement requires a proper source and propagation model. As these models may change it is recommended to measure and report both SEL and L{sub pFmax} normalized to a specified distance.

  2. Measurement and simulation of laser power noise in GEO 600

    International Nuclear Information System (INIS)

    Smith, J R; Degallaix, J; Freise, A; Grote, H; Hewitson, M; Hild, S; Lueck, H; Strain, K A; Willke, B

    2008-01-01

    This paper describes measurements and simulations related to power fluctuations of the laser light in the GEO 600 laser-interferometric gravitational wave detector. Measurements of the relative fluctuations of the light power at three different ports of the main interferometer are presented. In addition, measurements and simulations of the coupling transfer functions from power fluctuations at the input laser to these ports are shown. The transfer function from the input laser to the output port of the interferometer is found to be non-trivial. Despite this, the numerical simulation produces an excellent match to it and gives insight to the mechanisms leading to the complicated shape. Furthermore, the coupling transfer functions of power fluctuations to the main (heterodyne) detector outputs are measured and simulated. These are used to evaluate the level with which laser power fluctuations contribute to the overall noise level of the instrument

  3. Noise from offshore wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Soendergaard, B.; Plovsing, B.

    2005-07-01

    Noise assessment of wind turbines through calculations is based on sound power levels measured according to e.g. IEC 61400-11. With larger wind turbines and distances some of the calculation models give erroneous results. Noise propagation over water is different from propagation over land. For that reason it is important be able to make valid noise assessments for offshore wind farms. A suggestion for an offshore measurement method is described and a survey of models for noise propagation offshore has been made. (au)

  4. Masking potency and whiteness of noise at various noise check sizes.

    Science.gov (United States)

    Kukkonen, H; Rovamo, J; Näsänen, R

    1995-02-01

    The masking effect of spatial noise can be increased by increasing either the rms contrast or check size of noise. In this study, the authors investigated the largest noise check size that still mimics the effect of white noise in grating detection and how it depends on the bandwidth and spatial frequency of a grating. The authors measured contrast energy thresholds, E, for vertical cosine gratings at various spatial frequencies and bandwidths. Gratings were embedded in two-dimensional spatial noise. The side length of the square noise checks was varied in the experiments. The spectral density, N(0,0), of white spatial noise at zero frequency was calculated by multiplying the noise check area by the rms contrast of noise squared. The physical signal-to-noise ratio at threshold [E/N(0,0)]0.5 was initially constant but then started to decrease. The largest noise check that still produced a constant physical signal-to-noise ratio at threshold was directly proportional to the spatial frequency. When expressed as a fraction of grating cycle, the largest noise check size depended only on stimulus bandwidth. The smallest number of noise checks per grating cycle needed to mimic the effect of white noise decreased from 4.2 to 2.6 when the number of grating cycles increased from 1 to 64. Spatial noise can be regarded as white in grating detection if there are at least four square noise checks per grating cycle at all spatial frequencies.

  5. Covariance-Based Estimation from Multisensor Delayed Measurements with Random Parameter Matrices and Correlated Noises

    Directory of Open Access Journals (Sweden)

    R. Caballero-Águila

    2014-01-01

    Full Text Available The optimal least-squares linear estimation problem is addressed for a class of discrete-time multisensor linear stochastic systems subject to randomly delayed measurements with different delay rates. For each sensor, a different binary sequence is used to model the delay process. The measured outputs are perturbed by both random parameter matrices and one-step autocorrelated and cross correlated noises. Using an innovation approach, computationally simple recursive algorithms are obtained for the prediction, filtering, and smoothing problems, without requiring full knowledge of the state-space model generating the signal process, but only the information provided by the delay probabilities and the mean and covariance functions of the processes (signal, random parameter matrices, and noises involved in the observation model. The accuracy of the estimators is measured by their error covariance matrices, which allow us to analyze the estimator performance in a numerical simulation example that illustrates the feasibility of the proposed algorithms.

  6. High Velocity Jet Noise Source Location and Reduction. Task 6. Noise Abatement Nozzle Design Guide.

    Science.gov (United States)

    1979-04-01

    the Conical Nozzle 255 on the Bertin Aerotrain . xvi ji4 ’ . _______ p .. LIST OF ILLUSTRATIONS (Continued) Figure Page D-37. Predicted and Measured...Moving-Frame Noise from the 256 Conical Nozzle on the Bertin Aerotrain . D-38. Predicted and Measured Static Noise from the 104-Tube 257 Nozzle on the...Bertin Aerotrain . D-39. Predicted and Measured Moving-Frame Noise from the 104- 258 Tube Nozzle on the Bertin Aerotrain . D-40. Relative Velocity Index m

  7. Selection of noise parameters for Kalman filter

    Institute of Scientific and Technical Information of China (English)

    Ka-Veng Yuen; Ka-In Hoi; Kai-Meng Mok

    2007-01-01

    The Bayesian probabilistic approach is proposed to estimate the process noise and measurement noise parameters for a Kalman filter. With state vectors and covariance matrices estimated by the Kalman filter, the likehood of the measurements can be constructed as a function of the process noise and measurement noise parameters. By maximizing the likklihood function with respect to these noise parameters, the optimal values can be obtained. Furthermore, the Bayesian probabilistic approach allows the associated uncertainty to be quantified. Examples using a single-degree-of-freedom system and a ten-story building illustrate the proposed method. The effect on the performance of the Kalman filter due to the selection of the process noise and measurement noise parameters was demonstrated. The optimal values of the noise parameters were found to be close to the actual values in the sense that the actual parameters were in the region with significant probability density. Through these examples, the Bayesian approach was shown to have the capability to provide accurate estimates of the noise parameters of the Kalman filter, and hence for state estimation.

  8. Report on inter-noise 99; Inter-noise 99 sanka hokok

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H. [Japan Automobile Research Institute Inc., Tsukuba (Japan)

    2000-04-01

    Inter-Noise (International Congress on Noise Control Engineering) is a society on noise/vibration and the control technology. Inter-Noise 99 was held on December 6, 7 and 8, 1999, at Fort Lauderdale, Florida, the U.S. The theme was Noise Control in the New Millennium. The number of the participants registered was 555 (151 from the U.S., 89 from Japan, 248 from European countries, and 69 from Asian/other countries). Dr. Harold Marshall gave a keynote lecture titled Noise Control by Design in the 21st Century - An Architectural Acoustic Perspective. From a standpoint of architectural acoustics, he stated the perspective, subjects, and course of the technical development pertaining to technologies needed in the 21st century. The papers read are mostly from the following fields: measuring technology, military exercise noise, modeling, forecast and simulation, aerodynamic/underwater sound, etc. In the session on the tire noise where the author read a paper, 14 papers were read. The number of the papers read was more than that in 1998, probably influenced by the tire noise regulation in Europe and Japan. (translated by NEDO)

  9. Measurement of the specific surface area of loose copper deposit by electrochemical methods

    Directory of Open Access Journals (Sweden)

    E. A. Dolmatova

    2016-07-01

    Full Text Available In the work the surface area of the electrode with dispersed copper deposit obtained within 30 seconds was evaluated by techniques of chronopotentiometry (CPM and impedance spectroscopy. In method CPM the electrode surface available for measurement depends on the value of the polarizing current. At high currents during the transition time there is a change of surface relief that can not determine the full surface of loose deposit. The electrochemical impedance method is devoid of this shortcoming since the measurements are carried out in indifferent electrolyte in the absence of current. The area measured by the impedance is tens of times higher than the value obtained by chronopotentiometry. It is found that from a solution containing sulfuric acid the deposits form with a high specific surface area. Based on these data it was concluded that the method of impedance spectroscopy can be used to measure in situ the surface area of the dispersed copper deposits.

  10. A theoretical model for measuring mass flowrate and quality of two phase flow by the noise of throttling set

    International Nuclear Information System (INIS)

    Tong Yunxian; Wang Wenran

    1992-03-01

    The mass flowrate and steam quality measuring of two phase flowrate is an essential issue in the tests of loss-of-coolant accident (LOCA). The spatial stochastic distribution of phase concentration would cause a differential pressure noise when two phase flow is crossing a throttling set. Under the assumption of that the variance of disperse phase concentration is proportional to its mean phase concentration and by using the separated flow model of two phase flow, it has demonstrated that the variance of noise of differential pressure square root is approximately proportional to the flowrate of disperse phase. Thus, a theoretical model for measuring mass flowrate and quality of two phase flow by noise measurement is developed. It indicates that there is a possibility to measure two phase flowrate and steam quality by using the simple theoretical model and a single throttling set

  11. Noise pollution from wind turbine gears loudness of structural noise sources related to gears

    International Nuclear Information System (INIS)

    Crone, A.

    1995-04-01

    The purpose of the project has been to develop a method for determination of the structure-borne noise source strength of the gearbox in a typical modern Danish wind turbine construction, with special reference to the tonal noise emission form the turbines. Through study and evaluation of eight potential methods, a simple method has ben formulated. The method is based on measurements of the free vibration velocity level on the gearbox in a load test bed. The relation between this source strength measure and the gearbox related noise from wind turbines has been documented by measurements made during the project together with earlier measurements. The method is intended as a tool for the wind turbine manufacturer, for control of the gearbox related noise from the wind turbines, due to structure-borne noise from the gearbox. It may be used for preparation of specifications to the gearbox manufacturer on test procedure and acceptable source strength levels. Also, it may be used for evaluation of the transmission and radiation of gearbox related noise, for example in order to uncover weaknesses in a prototype turbine. Suggestions for adaptation and evolution of the method has been given, thereby improving the strength of the method for the individual wind turbine manufacturer. (au) 19 refs

  12. Electronic quantum noise and microwave photons

    International Nuclear Information System (INIS)

    Bize-Reydellet, L.H.

    2003-06-01

    This work is devoted to the experimental study of quantum electronic noise in mesoscopic conductors. In the first part of this thesis, we studied shot noise in a one-dimensional ballistic conductor: a quantum point contact (QPC). We showed experimentally that, when one of the QPC contacts is irradiated with microwave photons, we observe partition noise in the absence of net current flowing through the sample. Thus, we validate the scattering theory of photo-assisted shot noise first by measuring the Fano factor without bias voltage across the conductor, and then by measuring shot noise in the doubly non equilibrium situation, where both a bias voltage and a microwave modulation are applied. In the second part, we realized the first tests of a new experimental set-up which will be able to measure high frequency noise of a mesoscopic conductor and the photon statistics emitted by this conductor in the measurement circuit. These tests consist in realizing Hanbury-Brown and Twiss type experiments (intensity interferometry) with two kinds of microwave photon source. First, we used a thermal incoherent source (macroscopic 50 Ohms resistor). It showed super-Poissonian noise, since the power fluctuations are proportional to the square of the mean photon power. Secondly, we studied a classical monochromatic source, which shows a Poissonian statistics. The giant Fano factor measured is perfectly explained by the attenuator and amplifier noise. (author)

  13. Phased Array Noise Source Localization Measurements Made on a Williams International FJ44 Engine

    Science.gov (United States)

    Podboy, Gary G.; Horvath, Csaba

    2010-01-01

    A 48-microphone planar phased array system was used to acquire noise source localization data on a full-scale Williams International FJ44 turbofan engine. Data were acquired with the array at three different locations relative to the engine, two on the side and one in front of the engine. At the two side locations the planar microphone array was parallel to the engine centerline; at the front location the array was perpendicular to the engine centerline. At each of the three locations, data were acquired at eleven different engine operating conditions ranging from engine idle to maximum (take off) speed. Data obtained with the array off to the side of the engine were spatially filtered to separate the inlet and nozzle noise. Tones occurring in the inlet and nozzle spectra were traced to the low and high speed spools within the engine. The phased array data indicate that the Inflow Control Device (ICD) used during this test was not acoustically transparent; instead, some of the noise emanating from the inlet reflected off of the inlet lip of the ICD. This reflection is a source of error for far field noise measurements made during the test. The data also indicate that a total temperature rake in the inlet of the engine is a source of fan noise.

  14. Characterization of Electrochemically Generated Silver

    Science.gov (United States)

    Adam, Niklas; Martinez, James; Carrier, Chris

    2014-01-01

    Silver biocide offers a potential advantage over iodine, the current state of the art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. Low concentrations of silver (Silver does not require hardware to remove it from a water system, and therefore can provide a simpler means for disinfecting water. The Russian segment of the International Space Station has utilized an electrochemically generated silver solution, which is colloidal in nature. To be able to reliably provide a silver biocide to drinking water by electrochemical means would reduce mass required for removing another biocide such as iodine from the water. This would also aid in crew time required to replace iodine removal cartridges. Future long term missions would benefit from electrochemically produced silver as the biocide could be produced on demand and requires only a small concentration to be effective. Since it can also be consumed safely, there is less mass in removal hardware and little consumables required for production. The goal of this project initially is to understand the nature of the electrochemically produced silver, the particle sizes produced by the electrochemical cell and the effect that voltage adjustment has on the particle size. In literature, it has been documented that dissolved oxygen and pH have an effect on the ionization of the electrochemical silver so those parameters would be measured and possibly adjusted to understand their effect on the silver.

  15. On the prediction of impact noise, V: The noise from drop hammers

    Science.gov (United States)

    Richards, E. J.; Carr, I.; Westcott, M.

    1983-06-01

    In earlier papers in this series, the concepts of "acceleration" and "ringing" noise have been studied in relation to impact machines, and values of radiation efficiency have been obtained for the various types of structural components. In the work reported in this paper the predicted and measured noise radiation from a drop hammer, both in full-scale and in {1}/{3}- scale model form, were examined. It is found that overall noise levels ( Leq per event) can be predicted from vibration measurements to within ± 1·5 dB, and to within ±2·5 dB in one-third octave bands. In turn this has permitted noise reduction techniques to be examined by studies of local component vibration levels rather than overall noise, a method which provides considerable enlightenment at the design stage. It is shown that on one particular drop hammer, the noise energy is shared surprisingly uniformly over four or five sources, and that when these have been reduced, the overall noise reduction is severely limited by the "acceleration" noise from the "tup" or "hammer" itself. As this is difficult to eliminate without a basic change in forging technology, it follows that "tup" enclosure or modification of the sharpness of the final "hard" impact are the only means available for any serious noise reduction. Also indicated is the reliability of using model techniques, suitably scaled in frequency and impulse magnitude, in developing machinery with impact characteristics.

  16. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  17. Evolution of tyre/road noise research in India: Investigations using statistical pass-by method and noise trailer

    Directory of Open Access Journals (Sweden)

    Vivek Khan

    2018-05-01

    Full Text Available The objective of this research study was to investigate and analyze the acoustical characteristics of asphalt concrete and cement concrete surface types by two noise measurement techniques: statistical pass-by (SPB and Close Proximity (CPX methods. A noise trailer was devised and manufactured as part of the CPX methodology to evaluate tyre/pavement noise interaction at source. Two national highway test sections covering over 11 km of asphalt and cement concrete surfaces were selected to carry out the noise measurements, and the effects of vehicle speeds and/or sizes on the overall noise profiles were investigated. The major contribution of this first of its kind study in India was the utilization of sophisticated tools and techniques to measure the tyre/pavement interaction noise at source through CPX, which helped correlate the influence of road surfaces on the generation of overall road traffic noise using SPB technique. The SPB method noise profiles revealed that the noise pressure levels increased with increasing vehicle speeds and weights. The noise trailer CPX findings corroborated the results obtained from the SPB method in that cement concrete surface produced a higher noise at source than that of the asphalt concrete surface by about 5 dBA. Further, there was about 5 dBA differential in noise between SPB and CPX methods for cement concrete pavement sections; also, there was about 10 dBA differential in noise between the two methods for asphalt concrete pavement stretches. Keywords: Tyre/road noise, Statistical pass-by, Close proximity, Noise trailer, Asphalt concrete, Cement concrete

  18. Electrochemical fabrication and electronic behavior of polypyrrole nano-fiber array devices

    International Nuclear Information System (INIS)

    Liu Ling; Zhao Yaomin; Jia Nengqin; Zhou Qin; Zhao Chongjun; Yan Manming; Jiang Zhiyu

    2006-01-01

    Electrochemically active Polypyrrole (PPy) nano-fiber array device was fabricated via electrochemical deposition method using aluminum anodic oxide (AAO) membrane as template. After alkaline treatment electrochemically active PPy nano-fiber lost electrochemical activity, and became electrochemically inactive PPy. The electronic properties of PPy nano-fiber array devices were measured by means of a simple method. It was found that for an indium-tin oxide/electrochemically inactive PPy nano-fiber device, the conductivity of nano-fiber increased with the increase of voltage applied on the two terminals of nano-fiber. The electrochemical inactive PPy nano-fiber might be used as a nano-fiber switching diode. Both Au/electrochemically active PPy and Au/electrochemically inactive PPy nano-fiber devices demonstrate rectifying behavior, and might have been used for further application as nano-rectifiers

  19. Electrochemical fabrication and electronic behavior of polypyrrole nano-fiber array devices

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Liu [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Yaomin, Zhao [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Nengqin, Jia [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Qin, Zhou [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Chongjun, Zhao [Photon Craft Project, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences and Japan Science and Technology Agency, Shanghai 201800 (China); Manming, Yan [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Zhiyu, Jiang [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China)

    2006-05-01

    Electrochemically active Polypyrrole (PPy) nano-fiber array device was fabricated via electrochemical deposition method using aluminum anodic oxide (AAO) membrane as template. After alkaline treatment electrochemically active PPy nano-fiber lost electrochemical activity, and became electrochemically inactive PPy. The electronic properties of PPy nano-fiber array devices were measured by means of a simple method. It was found that for an indium-tin oxide/electrochemically inactive PPy nano-fiber device, the conductivity of nano-fiber increased with the increase of voltage applied on the two terminals of nano-fiber. The electrochemical inactive PPy nano-fiber might be used as a nano-fiber switching diode. Both Au/electrochemically active PPy and Au/electrochemically inactive PPy nano-fiber devices demonstrate rectifying behavior, and might have been used for further application as nano-rectifiers.

  20. Occupational Noise Reduction in CNC Striping Process

    Science.gov (United States)

    Mahmad Khairai, Kamarulzaman; Shamime Salleh, Nurul; Razlan Yusoff, Ahmad

    2018-03-01

    Occupational noise hearing loss with high level exposure is common occupational hazards. In CNC striping process, employee that exposed to high noise level for a long time as 8-hour contributes to hearing loss, create physical and psychological stress that reduce productivity. In this paper, CNC stripping process with high level noises are measured and reduced to the permissible noise exposure. First condition is all machines shutting down and second condition when all CNC machine under operations. For both conditions, noise exposures were measured to evaluate the noise problems and sources. After improvement made, the noise exposures were measured to evaluate the effectiveness of reduction. The initial average noise level at the first condition is 95.797 dB (A). After the pneumatic system with leakage was solved, the noise reduced to 55.517 dB (A). The average noise level at the second condition is 109.340 dB (A). After six machines were gathered at one area and cover that area with plastic curtain, the noise reduced to 95.209 dB (A). In conclusion, the noise level exposure in CNC striping machine is high and exceed the permissible noise exposure can be reduced to acceptable levels. The reduction of noise level in CNC striping processes enhanced productivity in the industry.

  1. Signal-to-noise ratio measurement in parallel MRI with subtraction mapping and consecutive methods

    International Nuclear Information System (INIS)

    Imai, Hiroshi; Miyati, Tosiaki; Ogura, Akio; Doi, Tsukasa; Tsuchihashi, Toshio; Machida, Yoshio; Kobayashi, Masato; Shimizu, Kouzou; Kitou, Yoshihiro

    2008-01-01

    When measuring the signal-to-noise ratio (SNR) of an image the used parallel magnetic resonance imaging, it was confirmed that there was a problem in the application of past SNR measurement. With the method of measuring the noise from the background signal, SNR with parallel imaging was higher than that without parallel imaging. In the subtraction method (NEMA standard), which sets a wide region of interest, the white noise was not evaluated correctly although SNR was close to the theoretical value. We proposed two techniques because SNR in parallel imaging was not uniform according to inhomogeneity of the coil sensitivity distribution and geometry factor. Using the first method (subtraction mapping), two images were scanned with identical parameters. The SNR in each pixel divided the running mean (7 by 7 pixels in neighborhood) by standard deviation/√2 in the same region of interest. Using the second (consecutive) method, more than fifty consecutive scans of the uniform phantom were obtained with identical scan parameters. Then the SNR was calculated from the ratio of mean signal intensity to the standard deviation in each pixel on a series of images. Moreover, geometry factors were calculated from SNRs with and without parallel imaging. The SNR and geometry factor using parallel imaging in the subtraction mapping method agreed with those of the consecutive method. Both methods make it possible to obtain a more detailed determination of SNR in parallel imaging and to calculate the geometry factor. (author)

  2. Measurement of low neutron-fluences using electrochemically etched PC and PET track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.; Dajko, G.; Turek, K.; Spurny, F.

    1979-01-01

    Systematic investigations have been carried out to study different properties of electrochemically etched (ECE) polycarbonate (PC) and polyethylene-terephthalate (PET) foils. The dependence of the density of background discharge spots on surface-thickness removal, electrical field strength and frequency of voltage is given. The effect of these parameters on the neutron sensitivity of polycarbonate and polyethylene-terephthalate foils irradiated at right angles to 14.7 MeV, 241 Am-Be and 252 Cf neutrons is also studied. With knowledge of the background and sensitivity data, the etching and electrical parameters are optimized for low neutron-fluence measurements. (author)

  3. Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

    International Nuclear Information System (INIS)

    Hwang, S. M.; Yu, K. K.; Lee, Y. H.; Kang, C. S.; Kim, K.; Lee, S. J.

    2013-01-01

    For sensitive measurements of micro-Tesla nuclear magnetic resonance (μT-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 fT√ Hz, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise μT-NMR experiments.

  4. Environmental impact assessment - baseline noise survey and noise impact assessment for Aurora Mine

    International Nuclear Information System (INIS)

    Yee, S.

    1996-01-01

    A noise impact assessment was conducted at Syncrude's proposed Aurora Mine site to comply with Alberta Energy and Utilities Board (AEUB) Noise Control Directive ID 94-4. Noise assessments were conducted near a major noise source, i.e. the hydraulic and electric shovels. Noise levels at 50 meters away from the source varied from 72.3 to 79.7 dBA. The worst case noise level was 75 dBA measured at 100 meters away from a hydraulic shovel. This assessment was used to calculate the predicted design sound level from a noise source at the nearest or most impacted occupied dwelling. Two cabins located near the access road and along Kearl Lake respectively, were identified as the most impacted and nearest dwellings to the mine site. The predicted sound level at one cabin was 43 dBA, and 55 dBA at the other. Fort McKay was also assessed because it is the nearest community to the mine site. The sound level at Fort McKay was predicted to be 34 dBA. These results indicate that the sound level from Aurora Mine is not in compliance with the AEUB Noise Control Directive. Attenuation measures are required to reduce the noise to acceptable level at Cabin A and B. Predicted sound level at Fort McKay is lower than the permitted sound level

  5. Filter apparatus for actively reducing noise

    NARCIS (Netherlands)

    Berkhoff, Arthur P.; Nijsse, G.

    2010-01-01

    A filter apparatus for reducing noise from a primary noise source, comprising a secondary source signal connector for generating secondary noise to reduce said primary noise and a sensor connector for connecting to a sensor for measuring said primary and secondary noise as an error signal. A first

  6. Acceptable noise level

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Nielsen, Lars Holme; Lantz, Johannes

    2012-01-01

    The acceptable noise level (ANL) is used to quantify the amount of background noise that subjects can accept while listening to speech, and is suggested for prediction of individual hearing-aid use. The aim of this study was to assess the repeatability of the ANL measured in normal-hearing subjects...... using running Danish and non-semantic speech materials as stimuli and modulated speech-spectrum and multi-talker babble noises as competing stimuli....

  7. Acceptable noise level

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Nielsen, Lars Holme; Lantz, Johannes

    2012-01-01

    The acceptable noise level (ANL) is used to quantify the amount of background noise that subjects can accept while listening to speech, and is suggested for prediction of individual hearing-aid use. The aim of this study was to assess the repeatability of the ANL measured in normal-hearing subjec...... using running Danish and non-semantic speech materials as stimuli and modulated speech-spectrum and multi-talker babble noises as competing stimuli....

  8. Measurement of macroscopic plasma parameters with a radio experiment: Interpretation of the quasi-thermal noise spectrum observed in the solar wind

    Science.gov (United States)

    Couturier, P.; Hoang, S.; Meyer-Vernet, N.; Steinberg, J. L.

    1983-01-01

    The ISEE-3 SBH radio receiver has provided the first systematic observations of the quasi-thermal (plasma waves) noise in the solar wind plasma. The theoretical interpretation of that noise involves the particle distribution function so that electric noise measurements with long antennas provide a fast and independent method of measuring plasma parameters: densities and temperatures of a two component (core and halo) electron distribution function have been obtained in that way. The polarization of that noise is frequency dependent and sensitive to the drift velocity of the electron population. Below the plasma frequency, there is evidence of a weak noise spectrum with spectral index -1 which is not yet accounted for by the theory. The theoretical treatment of the noise associated with the low energy (thermal) proton population shows that the moving electrical antenna radiates in the surrounding plasma by Carenkov emission which becomes predominant at the low frequencies, below about 0.1 F sub P.

  9. A multi-time-step noise reduction method for measuring velocity statistics from particle tracking velocimetry

    Science.gov (United States)

    Machicoane, Nathanaël; López-Caballero, Miguel; Bourgoin, Mickael; Aliseda, Alberto; Volk, Romain

    2017-10-01

    We present a method to improve the accuracy of velocity measurements for fluid flow or particles immersed in it, based on a multi-time-step approach that allows for cancellation of noise in the velocity measurements. Improved velocity statistics, a critical element in turbulent flow measurements, can be computed from the combination of the velocity moments computed using standard particle tracking velocimetry (PTV) or particle image velocimetry (PIV) techniques for data sets that have been collected over different values of time intervals between images. This method produces Eulerian velocity fields and Lagrangian velocity statistics with much lower noise levels compared to standard PIV or PTV measurements, without the need of filtering and/or windowing. Particle displacement between two frames is computed for multiple different time-step values between frames in a canonical experiment of homogeneous isotropic turbulence. The second order velocity structure function of the flow is computed with the new method and compared to results from traditional measurement techniques in the literature. Increased accuracy is also demonstrated by comparing the dissipation rate of turbulent kinetic energy measured from this function against previously validated measurements.

  10. Simulation of reactor noise analysis measurement for light-water critical assembly TCA using MCNP-DSP

    International Nuclear Information System (INIS)

    Yamamoto, Toshihiro; Sakurai, Kiyoshi; Tonoike, Kotaro; Miyoshi, Yoshinori

    2001-01-01

    Reactor noise analysis methods using Monte Carlo technique have been proposed and developed in the field of nuclear criticality safety. The Monte Carlo simulation for noise analysis can be made by simulating physical phenomena in the course of neutron transport in a nuclear fuel as practically as possible. MCNP-DSP was developed by T. Valentine of ORNL for this purpose and it is a modified version of MCNP-4A. The authors applied this code to frequency analysis measurements performed in light-water critical assembly TCA. Prompt neutron generation times for critical and subcritical cores were measured by doing the frequency analysis of detector signals. The Monte Carlo simulations for these experiments were carried out using MCNP-DSP, and prompt neutron generation times were calculated. (author)

  11. The effect of signal to noise ratio on accuracy of temperature measurements for Brillouin lidar in water

    Science.gov (United States)

    Liang, Kun; Niu, Qunjie; Wu, Xiangkui; Xu, Jiaqi; Peng, Li; Zhou, Bo

    2017-09-01

    A lidar system with Fabry-Pérot etalon and an intensified charge coupled device can be used to obtain the scattering spectrum of the ocean and retrieve oceanic temperature profiles. However, the spectrum would be polluted by noise and result in a measurement error. To analyze the effect of signal to noise ratio (SNR) on the accuracy of measurements for Brillouin lidar in water, the theory model and characteristics of SNR are researched. The noise spectrums with different SNR are repetitiously measured based on simulation and experiment. The results show that accuracy is related to SNR, and considering the balance of time consumption and quality, the average of five measurements is adapted for real remote sensing under the pulse laser conditions of wavelength 532 nm, pulse energy 650 mJ, repetition rate 10 Hz, pulse width 8 ns and linewidth 0.003 cm-1 (90 MHz). Measuring with the Brillouin linewidth has a better accuracy at a lower temperature (15 °C), based on the classical retrieval model we adopt. The experimental results show that the temperature error is 0.71 °C and 0.06 °C based on shift and linewidth respectively when the image SNR is at the range of 3.2 dB-3.9 dB.

  12. Measurements and Predictions of the Noise from Three-Stream Jets

    Science.gov (United States)

    Henderson, Brenda S.; Leib, Stewart J.; Wernet, Mark P.

    2015-01-01

    An experimental and numerical investigation of the noise produced by high-subsonic and supersonic three-stream jets was conducted. The exhaust system consisted of externally-mixed-convergent nozzles and an external plug. Bypass- and tertiary-to-core area ratios between 1.0 and 2.5, and 0.4 and 1.0, respectively, were studied. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated conditions. For axisymmetric configurations, the addition of the third stream was found to reduce peak- and high-frequency acoustic levels in the peak-jet-noise direction, with greater reductions at the lower bypass-to-core area ratios. For the offset configurations, an offset duct was found to decrease acoustic levels on the thick side of the tertiary nozzle relative to those produced by the simulated two-stream jet with up to 8 dB mid-frequency noise reduction at large angles to the jet inlet axis. Noise reduction in the peak-jet-noise direction was greater for supersonic core speeds than for subsonic core speeds. The addition of a tertiary nozzle insert used to divert the third-stream jet to one side of the nozzle system provided no noise reduction. Noise predictions are presented for selected cases using a method based on an acoustic analogy with mean flow interaction effects accounted for using a Green's function, computed in terms of its coupled azimuthal modes for the offset cases, and a source model previously used for round and rectangular jets. Comparisons of the prediction results with data show that the noise model predicts the observed increase in low-frequency noise with the introduction of a third, axisymmetric stream, but not the high-frequency reduction. For an offset third stream, the model predicts the observed trend of decreased sound levels on the thick side of the jet compared with the thin side, but the predicted azimuthal variations are much less than those seen in the data. Also, the shift of the spectral peak to lower frequencies with

  13. Measurement and analysis of the noise radiated by low Mach numbers centrifugal blowers

    Science.gov (United States)

    Yeager, D. M.; Lauchle, G. C.

    1987-11-01

    The broad band, aerodynamically generated noise in low tip-speed Mach number, centrifugal air moving devices is investigated. An interdisciplinary approach was taken which involved investigation of the aerodynamic and acoustic fields, and their mutual relationship. The noise generation process was studied using two experimental vehicles: (1) a scale model of a homologous family of centrifugal blowers typical of those used to cool computer and business equipment, and (2) a single blade from a centrifugal blower impeller which was placed in a known, controllable flow field. The radiation characteristics of the model blower were investigated by measuring the acoustic intensity distribution near the blower inlet and comparing it with the intensity near the inlet to an axial flow fan. Aerodynamic studies of the flow field in the inlet and at the discharge to the rotating impeller were used to assess the mean flow distribution through the impeller blade channels and to identify regions of excessive turbulence near the rotating blade row. New frequency-domain expressions for the correlation area and dipole source strength per unit area on a surface immersed in turbulence were developed which can be used to characterize the noise generation process over a rigid surface immersed in turbulence. An investigation of the noise radiated from the single, isolated airfoil (impeller blade) was performed using modern correlation and spectral analysis techniques.

  14. An image-processing method to detect sub-optical features based on understanding noise in intensity measurements.

    Science.gov (United States)

    Bhatia, Tripta

    2018-02-01

    Accurate quantitative analysis of image data requires that we distinguish between fluorescence intensity (true signal) and the noise inherent to its measurements to the extent possible. We image multilamellar membrane tubes and beads that grow from defects in the fluid lamellar phase of the lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine dissolved in water and water-glycerol mixtures by using fluorescence confocal polarizing microscope. We quantify image noise and determine the noise statistics. Understanding the nature of image noise also helps in optimizing image processing to detect sub-optical features, which would otherwise remain hidden. We use an image-processing technique "optimum smoothening" to improve the signal-to-noise ratio of features of interest without smearing their structural details. A high SNR renders desired positional accuracy with which it is possible to resolve features of interest with width below optical resolution. Using optimum smoothening, the smallest and the largest core diameter detected is of width [Formula: see text] and [Formula: see text] nm, respectively, discussed in this paper. The image-processing and analysis techniques and the noise modeling discussed in this paper can be used for detailed morphological analysis of features down to sub-optical length scales that are obtained by any kind of fluorescence intensity imaging in the raster mode.

  15. Road Traffic Noise Pollution Analysis for Cernavoda City

    Science.gov (United States)

    Manea, L.; Manea, A.; Florea, D.; Tarulescu, S.

    2017-10-01

    In the present paper was studied the noise pollution in Cernavodă city. The noise measurements were made for nine intersections from different city areas. Noise measurements were taken for three chosen routes with high population density, heavy traffic, commercial and residential buildings. Average, maximum and minimum values were collected and compared with standards. The impact of road traffic noise on the community depends on various factors such as road location and design, land use planning measures, building design, traffic composition, driver behaviour and the relief. In the study area 9 locations are identified to measure noise level. By using sound level meter noise levels are measured at different peak sessions i.e. morning, afternoon and evening. The presented values were collected for evening rush hour.

  16. Electrochemical techniques for practical evaluation of corrosion inhibitor effectiveness. Performance of cerium nitrate as corrosion inhibitor for AA2024T3 alloy

    International Nuclear Information System (INIS)

    Rosero-Navarro, N.C.; Curioni, M.; Bingham, R.; Duran, A.; Aparicio, M.; Cottis, R.A.; Thompson, G.E.

    2010-01-01

    In this work, a split-cell technique and image-assisted electrochemical noise analysis, which provide minimal perturbation of the freely corroding system and good time resolution, are proposed as a tool for simultaneous investigation of the corrosion inhibition mechanism and assessment of performance. The results obtained are compared with results from traditional electrochemical impedance spectroscopy, disclosing the advantages of these techniques in the evaluation of inhibitor performance. Specific attention is also given to the investigation of corrosion inhibition by cerium nitrate.

  17. Separation of rolling noise and aerodynamic noise by in-service measurement of combined roughness and transfer functions on a high speed slab track

    NARCIS (Netherlands)

    Jansen, H.W.; Dittrich, M.G.

    2012-01-01

    Combined sound and vibration measurements during train pass-bys can be used to quantify contributions from the excitation and transmission of rolling noise. This is useful for the identification of sound sources and the assessment of the track contribution. In this paper, a practical application on

  18. Design of a high-speed electrochemical scanning tunneling microscope.

    Science.gov (United States)

    Yanson, Y I; Schenkel, F; Rost, M J

    2013-02-01

    In this paper, we present a bottom-up approach to designing and constructing a high-speed electrochemical scanning tunneling microscope (EC-STM). Using finite element analysis (FEA) calculations of the frequency response of the whole mechanical loop of the STM, we analyzed several geometries to find the most stable one that could facilitate fast scanning. To test the FEA results, we conducted measurements of the vibration amplitudes using a prototype STM setup. Based on the FEA analysis and the measurement results, we identified the potentially most disturbing vibration modes that could impair fast scanning. By modifying the design of some parts of the EC-STM, we reduced the amplitudes as well as increased the resonance frequencies of these modes. Additionally, we designed and constructed an electrochemical flow-cell that allows STM imaging in a flowing electrolyte, and built a bi-potentiostat to achieve electrochemical potential control during the measurements. Finally, we present STM images acquired during high-speed imaging in air as well as in an electrochemical environment using our newly-developed EC-STM.

  19. Lifetime measurement of prompt neutrons using the neutronic noise analysis

    International Nuclear Information System (INIS)

    Ortiz Servin, J.J.

    1992-01-01

    The purpose of this work is to estimate the life of the prompt neutrons, i, of a nuclear reactor utilizing the neutron noise analysis. This technique carry to development of mathematical model that is valid for lower powers reactor. The equation resulting convey to the observation about power spectrum behaviour respect to the frecquency. In this case, the reactor in study is the Triga Mark III of Nuclear Center of Mexico that it was provided of fission chambers for register the neutron fluxes. These fluxes was digitized and storage in computer disc as signals dependents of time, for later apply the Fourier Transformation and obtain the spectras. The spectras measured to different reactor powers were adjusted to the development equation before, using the method of square minimum and so estimate the parameter i. The analysis of results throw a value of 22.73 +/- 0.92 μs. On the other hand, the calculate value to the resolve the kinetic equation of reactor defer in lower than 4 % about the estimate. Of this, it concludes that the model utilized is trusty with a good mistake margin, moreover of that the technique of Neutron Noise analysis demonstrate be competitive (Author)

  20. Electrochemical and CMT measurements of the anomalous dissolution of nickel in solutions containing oxygen

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; de Fontenay, Frank; Poulsen, Henning

    1997-01-01

    In addition to single nickel crystals also nickel samples produced by dc and pr (pulse-reversal) plating were examined. As previously reported the true rate of dissolution of nickel in solutions containing oxygen was found to be as much as three times the electrochemical rate at the corrosion...... potential. When passivation was approached (spontaneously or by anodic polarization) the true rate of dissolution approached the rate of anodic reaction. During cathodic polarization there was still a significant rate of dissolution. The true rate of dissolution was determined by CMT measurements (Corrosion...

  1. A Background Noise Reduction Technique Using Adaptive Noise Cancellation for Microphone Arrays

    Science.gov (United States)

    Spalt, Taylor B.; Fuller, Christopher R.; Brooks, Thomas F.; Humphreys, William M., Jr.; Brooks, Thomas F.

    2011-01-01

    Background noise in wind tunnel environments poses a challenge to acoustic measurements due to possible low or negative Signal to Noise Ratios (SNRs) present in the testing environment. This paper overviews the application of time domain Adaptive Noise Cancellation (ANC) to microphone array signals with an intended application of background noise reduction in wind tunnels. An experiment was conducted to simulate background noise from a wind tunnel circuit measured by an out-of-flow microphone array in the tunnel test section. A reference microphone was used to acquire a background noise signal which interfered with the desired primary noise source signal at the array. The technique s efficacy was investigated using frequency spectra from the array microphones, array beamforming of the point source region, and subsequent deconvolution using the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm. Comparisons were made with the conventional techniques for improving SNR of spectral and Cross-Spectral Matrix subtraction. The method was seen to recover the primary signal level in SNRs as low as -29 dB and outperform the conventional methods. A second processing approach using the center array microphone as the noise reference was investigated for more general applicability of the ANC technique. It outperformed the conventional methods at the -29 dB SNR but yielded less accurate results when coherence over the array dropped. This approach could possibly improve conventional testing methodology but must be investigated further under more realistic testing conditions.

  2. Spatial noise in staring IR focal plane arrays

    International Nuclear Information System (INIS)

    Scribner, D.A.; Kruer, M.R.; Sarkady, K.; Gridley, J.C.

    1988-01-01

    Problems with nonuniformity correction algorithms due to nonlinear pixel response and 1/f noise have been shown previously to cause spatial noise which can be significantly greater than temporal noise. The residual spatial noise after correction cannot be reduced with time averaging. Because of spatial noise the sensitivity of staring FPA sensors is often less than predicted on the basis of the temporal noise of the individual elements. A review is given of methods for measuring and analyzing spatial noise (after nonuniformity correction) in staring infrared focal plane arrays. Automated measurement techniques are described briefly, including necessary equipment and data reduction procedures. An example of spatial noise measurements is given using a staring InSb Charge Injection Device (CID) array

  3. Gating in time domain as a tool for improving the signal-to-noise ratio of beam transfer function measurements

    CERN Document Server

    Oeftiger, U; Caspers, Fritz

    1992-01-01

    For the measurement of Beam Transfer Functions the signal-to-noise ratio is of great importance. In order to get a reasonable quality of the measured data one may apply averaging and smoothing. In the following another technique called time gating to improve the quality of the measurement will be described. By this technique the measurement data are Fourier transformed and then modified in time domain. Tune gating suppresses signal contributions that are correlated to a time interval when no interesting information is expected. Afterivards an inverse Fourier transform leads to data in frequency domain with an improved signal to noise ratio.

  4. Noise from wind turbines

    International Nuclear Information System (INIS)

    Andersen, B.; Larsen, P.

    1993-01-01

    Denmark has 3200 wind turbines with an installed maximum capacity of 418MW. The most important Danish research projects into wind turbine noise and the main results are listed. These date from 1983. Two comprehensive studies are currently in progress. The first is an analytical and empirical investigation of aerodynamic noise from wind turbine rotors and has so far dealt mainly with tip noise. The measurement method, using a hard board mounted microphone on the ground near the turbine, is described. Four different tip designs have been tested. Some examples of reference sound power level spectra for three of the designs are presented. During the past two years a computerbased data acquisition system has been used for real-time determination of sound power levels. The second study, which has just commenced, is on annoyance from wind turbine noise. It will include noise measurements, masking calculations and a social survey on the perceived nuisance. (UK)

  5. Noise from wind turbines

    International Nuclear Information System (INIS)

    Andersen, B.; Jakobsen, J.

    1992-11-01

    Based on a previous project concerning the calculation of the amount of noise emanating from wind turbine arrays, this one examines the subject further by investigating whether there could be significant differences in the amount of noise made by individual wind turbines in an array, and whether the noise is transmitted in varying directions - so that when it is carried in the same direction as the wind blows it would appear to be louder. The aim was also to determine whether the previously used method of calculation lacked precision. It was found that differences in noise niveaux related to individual wind turbines were insignificant and that noise was not so loud when it was not borne in the direction of the wind. It was necessary to change the method of calculation as reckoning should include the influence of the terrain, wind velocity and distance. The measuring and calculation methods are exemplified and the resulting measurements are presented in detail. (AB)

  6. Indirect Combustion Noise: Noise Generation by Accelerated Vorticity in a Nozzle Flow

    Directory of Open Access Journals (Sweden)

    Nancy Kings

    2010-09-01

    Full Text Available The noise generation by accelerated vorticity waves in a nozzle flow was investigated in a model experiment. This noise generation mechanism belongs, besides entropy noise, to the indirect combustion noise phenomena. Vorticity as well as entropy fluctuations, originating from the highly turbulent combustion zone, are convected with the flow and produce noise during their acceleration in the outlet nozzle of the combustion chamber. In the model experiment, noise generation of accelerated vorticity fluctuations was achieved. The vorticity fluctuations in the tube flow were produced by injecting temporally additional air into the mean flow. As the next step, a parametric study was conducted to determine the major dependencies of the so called vortex noise. A quadratic dependency of the vortex noise on the injected air amount was found. In order to visualise and classify the artificially generated vorticity structures, planar velocity measurements have been conducted applying Particle Image Velocimetry (PIV.

  7. MOSFET LF noise under Large Signal Excitation: Measurement, Modelling and Application

    NARCIS (Netherlands)

    van der Wel, A.P.

    2005-01-01

    Regarding LF noise in MOSFETs, it is noted that the MOSFET is a surface channel device. Both n and p-channel devices exhibit similar low frequency (LF) noise behaviour that can be explained by a carrier number fluctuation model (section 3.5). LF noise in MOSFETs is predominantly caused by Random

  8. Non-Markovian stochastic Schroedinger equations: Generalization to real-valued noise using quantum-measurement theory

    International Nuclear Information System (INIS)

    Gambetta, Jay; Wiseman, H.M.

    2002-01-01

    Do stochastic Schroedinger equations, also known as unravelings, have a physical interpretation? In the Markovian limit, where the system on average obeys a master equation, the answer is yes. Markovian stochastic Schroedinger equations generate quantum trajectories for the system state conditioned on continuously monitoring the bath. For a given master equation, there are many different unravelings, corresponding to different sorts of measurement on the bath. In this paper we address the non-Markovian case, and in particular the sort of stochastic Schroedinger equation introduced by Strunz, Diosi, and Gisin [Phys. Rev. Lett. 82, 1801 (1999)]. Using a quantum-measurement theory approach, we rederive their unraveling that involves complex-valued Gaussian noise. We also derive an unraveling involving real-valued Gaussian noise. We show that in the Markovian limit, these two unravelings correspond to heterodyne and homodyne detection, respectively. Although we use quantum-measurement theory to define these unravelings, we conclude that the stochastic evolution of the system state is not a true quantum trajectory, as the identity of the state through time is a fiction

  9. Aerodynamical noise from wind turbine generators

    International Nuclear Information System (INIS)

    Jakobsen, J.; Andersen, B.

    1993-06-01

    Two extensive measurement series of noise from wind turbines have been made during different modifications of their rotors. One series focused on the influence from the tip shape on the noise, while the other series dealt with the influence from the trailing edge. The experimental layout for the two investigations was identical. The total A-weighted noise from the wind turbine was measured in 1/3 octave bands from 50 Hz to 10 kHz in 1-minute periods simultaneously with wind speed measurements. The microphone was mounted on a hard board on the ground about 40 m directly downwind of the wind turbine, and the wind speed meter was placed at the same distance upwind of the wind turbine 10 m above ground. Regression analysis was made between noise and wind speed in each 1/3 octave band to determine the spectrum at 8 m/s. During the measurements care was taken to avoid influence from background noise, and the influence from machinery noise was minimized and corrected for. Thus the results display the aerodynamic rotor noise from the wind turbines. By use of this measurement technique, the uncertainty has been reduced to 1.5 - 2 dB per 1/3 octave band in the relevant frequency range and to about 1 dB on the total A-weighted levels. (au) (10 refs.)

  10. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  11. A 0.18 μm biosensor front-end based on 1/f noise, distortion cancelation and chopper stabilization techniques.

    Science.gov (United States)

    Balasubramanian, Viswanathan; Ruedi, Pierre-Francois; Temiz, Yuksel; Ferretti, Anna; Guiducci, Carlotta; Enz

    2013-10-01

    This paper presents a novel sensor front-end circuit that addresses the issues of 1/f noise and distortion in a unique way by using canceling techniques. The proposed front-end is a fully differential transimpedance amplifier (TIA) targeted for current mode electrochemical biosensing applications. In this paper, we discuss the architecture of this canceling based front-end and the optimization methods followed for achieving low noise, low distortion performance at minimum current consumption are presented. To validate the employed canceling based front-end, it has been realized in a 0.18 μm CMOS process and the characterization results are presented. The front-end has also been tested as part of a complete wireless sensing system and the cyclic voltammetry (CV) test results from electrochemical sensors are provided. Overall current consumption in the front-end is 50 μA while operating on a 1.8 V supply.

  12. Development of Advanced Electrochemical Emission Spectroscopy for Monitoring Corrosion in Simulated DOE Liquid Waste

    Energy Technology Data Exchange (ETDEWEB)

    Digby Macdonald; Brian Marx; Balaji Soundararajan; Morgan Smith

    2005-07-28

    The different tasks that have been carried out under the current program are as follows: (1) Theoretical and experimental assessment of general corrosion of iron/steel in borate buffer solutions by using electrochemical impedance spectroscopy (EIS), ellipsometry and XPS techniques; (2) Development of a damage function analysis (DFA), which would help in predicting the accumulation of damage due to pitting corrosion in an environment prototypical of DOE liquid waste systems; (3) Experimental measurement of crack growth rate, acoustic emission signals, and coupling currents for fracture in carbon and low alloy steels as functions of mechanical (stress intensity), chemical (conductivity), electrochemical (corrosion potential, ECP), and microstructural (grain size, precipitate size, etc) variables in a systematic manner, with particular attention being focused on the structure of the noise in the current and its correlation with the acoustic emissions; (4) Development of fracture mechanisms for carbon and low alloy steels that are consistent with the crack growth rate, coupling current data and acoustic emissions; (5) Inserting advanced crack growth rate models for SCC into existing deterministic codes for predicting the evolution of corrosion damage in DOE liquid waste storage tanks; (6) Computer simulation of the anodic and cathodic activity on the surface of the steel samples in order to exactly predict the corrosion mechanisms; (7) Wavelet analysis of EC noise data from steel samples undergoing corrosion in an environment similar to that of the high level waste storage containers, to extract data pertaining to general, pitting and stress corrosion processes, from the overall data. The work has yielded a number of important findings, including an unequivocal demonstration of the role of chloride ion in passivity breakdown on nickel in terms of cation vacancy generation within the passive film, the first detection and characterization of individual micro fracture

  13. Practical performance of real-time shot-noise measurement in continuous-variable quantum key distribution

    Science.gov (United States)

    Wang, Tao; Huang, Peng; Zhou, Yingming; Liu, Weiqi; Zeng, Guihua

    2018-01-01

    In a practical continuous-variable quantum key distribution (CVQKD) system, real-time shot-noise measurement (RTSNM) is an essential procedure for preventing the eavesdropper exploiting the practical security loopholes. However, the performance of this procedure itself is not analyzed under the real-world condition. Therefore, we indicate the RTSNM practical performance and investigate its effects on the CVQKD system. In particular, due to the finite-size effect, the shot-noise measurement at the receiver's side may decrease the precision of parameter estimation and consequently result in a tight security bound. To mitigate that, we optimize the block size for RTSNM under the ensemble size limitation to maximize the secure key rate. Moreover, the effect of finite dynamics of amplitude modulator in this scheme is studied and its mitigation method is also proposed. Our work indicates the practical performance of RTSNM and provides the real secret key rate under it.

  14. Monitoring the electrochemical responses of neurotransmitters through localized surface plasmon resonance using nanohole array.

    Science.gov (United States)

    Li, Nantao; Lu, Yanli; Li, Shuang; Zhang, Qian; Wu, Jiajia; Jiang, Jing; Liu, Gang Logan; Liu, Qingjun

    2017-07-15

    In this study, a novel spectroelectrochemical method was proposed for neurotransmitters detection. The central sensing device was a hybrid structure of nanohole array and gold nanoparticles, which demonstrated good conductivity and high localized surface plasmon resonance (LSPR) sensitivity. By utilizing such specially-designed nanoplasmonic sensor as working electrode, both electrical and spectral responses on the surface of the sensor could be simultaneously detected during the electrochemical process. Cyclic voltammetry was implemented to activate the oxidation and recovery of dopamine and serotonin, while transmission spectrum measurement was carried out to synchronously record to LSPR responses of the nanoplasmonic sensor. Coupling with electrochemistry, LSPR results indicated good integrity and linearity, along with promising accuracy in qualitative and quantitative detection even for mixed solution and in brain tissue homogenates. Also, the detection results of other negatively-charged neurotransmitters like acetylcholine demonstrated the selectivity of our detection method for transmitters with positive charge. When compared with traditional electrochemical signals, LSPR signals provided better signal-to-noise ratio and lower detection limits, along with immunity against interference factors like ascorbic acid. Taking the advantages of such robustness, the coupled detection method was proved to be a promising platform for point-of-care testing for neurotransmitters. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Validating criticality calculations for spent fuel with 252Cf-source-driven noise measurements

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Krass, A.W.; Valentine, T.E.

    1992-01-01

    The 252 Cf-Source-driven noise analysis method can be used for measuring the subcritical neutron multiplication factor k of arrays of spent light water reactor (LWR) fuel. This type of measurement provides a parameter that is directly related to the criticality state of arrays of LWR fuel. Measurements of this parameter can verify the criticality safety margins of spent LWR fuel configurations and thus could be a means of obtaining the information to justify burnup credit for spent LWR transportation/storage casks. The practicality of a measurement depends on the ability to install the hardware required to perform the measurement. Source chambers containing the 252 Cf at the required source intensity for this application have been constructed and have operated successfully for ∼10 years and can be fabricated to fit into control rod guide tubes of PWR fuel elements. Fission counters especially developed for spent-fuel measurements are available that would allow measurements of a special 3 x 3 spent fuel array and a typical burnup credit rail cask with spent fuel in unborated water. Adding a moderator around these fission counters would allow measurements with the typical burnup credit rail cask with borated water and the special 3 x 3 array with borated water. The recent work of Ficaro on modifying the KENO Va code to calculate by the Monte Carlo method the time sequences of pulses at two detectors near a fissile assembly from the fission chain multiplication process, initiated by a 252 Cf source in the assembly allows a direct computer calculation of the noise analysis data from this measurement method

  16. Electrochemical impedance spectroscopy (EIS) as a tool for measuring corrosion of polymer-coated fasteners used in treated wood

    Science.gov (United States)

    Samuel L. Zelinka; Lorraine Ortiz-Candelaria; Donald S. Stone; Douglas R. Rammer

    2009-01-01

    Currently, many of the polymer-coated fasteners on the market are designed for improved corrosion performance in treated wood; yet, there is no way to evaluate their corrosion performance. In this study, a common technique for measuring the corrosion performance of polymer-coated metals, electrochemical impedance spectroscopy (EIS), was used to evaluate commercial...

  17. Brake noise measurements on mixed freight trains with composite brake blocks

    NARCIS (Netherlands)

    Jansen, E.H.W.; Dittrich, M.G.; Sikma, E.L.

    2008-01-01

    Brake noise is known to be a major contributor to the total sound emission of railway yards and areas near stations. It has been established that composite brake blocks reduce rolling noise, but it is not known if this is also the case for braking noise. Therefore, in order to investigate this,

  18. Active microphonic noise cancellation in radiation detectors

    International Nuclear Information System (INIS)

    Zimmermann, Sergio

    2013-01-01

    A new adaptive filtering technique to reduce microphonic noise in radiation detectors is presented. The technique is based on system identification that actively cancels the microphonic noise. A sensor is used to measures mechanical disturbances that cause vibration on the detector assembly, and the digital adaptive filtering estimates the impact of these disturbances on the microphonic noise. The noise then can be subtracted from the actual detector measurement. In this paper the technique is presented and simulations are used to support this approach. -- Highlights: •A sensor is used to measures mechanical disturbances that cause vibration on the detector assembly. •Digital adaptive filtering estimates the impact of these disturbances on the microphonic noise. •The noise is then subtracted from the actual detector measurement. •We use simulations to demonstrate the performance of this approach. •After cancellation, we recover most of the original energy resolution

  19. Chicago transit authority train noise exposure.

    Science.gov (United States)

    Phan, Linh T; Jones, Rachael M

    2017-06-01

    To characterize noise exposure of riders on Chicago Transit Authority (CTA) trains, we measured noise levels twice on each segment of 7 of the 8 CTA train lines, which are named after colors, yielding 48 time-series measurements. We found the Blue Line has the highest noise levels compared to other train lines, with mean 76.9 dBA; and that the maximum noise level, 88.9 dBA occurred in the tunnel between the Chicago and Grand stations. Train segments involving travel through a tunnel had significantly higher noise levels than segments with travel on elevated and ground level tracks. While 8-hr doses inside the passenger cars were not estimated to exceed occupational exposure limits, train operators ride in a separate cab with operational windows and may therefore have higher noise exposures than riders. Despite the low risk of hearing loss for riders on CTA trains, in part because transit noise accounts for a small part of total daily noise exposure, 1-min average noise levels exceeded 85 dBA at times. This confirms anecdotal observations of discomfort due to noise levels, and indicates a need for noise management, particularly in tunnels.

  20. Study of the road traffic noise in Erzurum-Turkey

    Directory of Open Access Journals (Sweden)

    Mahir Gökdag

    2012-12-01

    Full Text Available Road traffic noise affects a large number of people, especially in urban areas and is generally a major source of complaints. This paper refers to a study of the problem of traffic noise on roads which have been transformed into streets in the city of Erzurum. Noise levels are measured and the impacts suffered by the community are documented. Manual noise measurements were made along 12 streets exploring sources of maximum noise levels. Noise from different types of vehicles driven in a realistic way in inner city traffic was measured. The results from the measurements showed that, of 750 measured events, approximately 5% of the vehicles exceeded 70 dB(A and less than 2% exceeded 80 dB(A maximum noise level. In summary, the result showed that the most important vehicle component as regards the maximum noise level in inner city traffic was a medium-weight vehicle. Among the higher noise levels measured (>80 dB(A this type of vehicle was dominant.

  1. Progressive evolution and a measure for its noise-dependent complexity

    Science.gov (United States)

    Fussy, Siegfried; Grössing, Gerhard; Schwabl, Herbert

    1999-03-01

    -Queen-effect." Additionally, for the memory based model a parameter was found indicating a limited range of noise allowing for the most complex behavior of the model, whereas the entropy of the system provides only a monotonous measure with respect to the varying noise level.

  2. Time-Distance Helioseismology: Noise Estimation

    Science.gov (United States)

    Gizon, L.; Birch, A. C.

    2004-10-01

    As in global helioseismology, the dominant source of noise in time-distance helioseismology measurements is realization noise due to the stochastic nature of the excitation mechanism of solar oscillations. Characterizing noise is important for the interpretation and inversion of time-distance measurements. In this paper we introduce a robust definition of travel time that can be applied to very noisy data. We then derive a simple model for the full covariance matrix of the travel-time measurements. This model depends only on the expectation value of the filtered power spectrum and assumes that solar oscillations are stationary and homogeneous on the solar surface. The validity of the model is confirmed through comparison with SOHO MDI measurements in a quiet-Sun region. We show that the correlation length of the noise in the travel times is about half the dominant wavelength of the filtered power spectrum. We also show that the signal-to-noise ratio in quiet-Sun travel-time maps increases roughly as the square root of the observation time and is at maximum for a distance near half the length scale of supergranulation.

  3. Loading Effect on Tire Noise Radiation

    OpenAIRE

    Cao, Rui; Bolton, J Stuart

    2016-01-01

    Noise radiated by tires is a prominent noise pollution source and it is affected by many different parameters. Here, the effect of static load on tire noise radiation in a laboratory environment was investigated. The measurement was conducted by using the Tire Pavement Testing Apparatus (TPTA), on which a loaded tire can be run at speeds up to 50 km/hr; the tire noise was measured using a nearfield microphone method. The tire loading was varied from 500 to 900 pounds, and several different co...

  4. Multichannel Bipotentiostat Integrated With a Microfluidic Platform for Electrochemical Real-Time Monitoring of Cell Cultures

    DEFF Research Database (Denmark)

    Vergani, Marco; Carminati, Marco; Ferrari, Giorgio

    2012-01-01

    An electrochemical detection system specifically designed for multi-parameter real-time monitoring of stem cell culturing/differentiation in a microfluidic system is presented. It is composed of a very compact 24-channel electronic board, compatible with arrays of microelectrodes and coupled...... to a microfluidic cell culture system. A versatile data acquisition software enables performing amperometry, cyclic voltammetry and impedance spectroscopy in each of the 12 independent chambers over a 100 kHz bandwidth with current resolution down to 5 pA for 100 ms measuring time. The design of the platform, its...... realization and experimental characterization are reported, with emphasis on the analysis of impact of input capacitance (i.e., microelectrode size) and microfluidic pump operation on current noise. Programmable sequences of successive injections of analytes (ferricyanide and dopamine) and rinsing buffer...

  5. The concept of floating electrode for contact-less electrochemical measurements: Application to reinforcing steel-bar corrosion in concrete

    International Nuclear Information System (INIS)

    Keddam, M.; Novoa, X.R.; Vivier, V.

    2009-01-01

    The concept of floating electrode is introduced for defining the common electrochemical behaviour of any non-connected, electronically conducting, body immersed in an electrolytic medium. The emphasis is put on both its own polarisation features and its influence on the d.c. and a.c. current and potential across the cell, hence the feasibility, among others, of contact-less electrochemical measurements on floating electrodes. Application to reinforcing steel bars in concrete is investigated by numerical computation of the a.c. current and potential fields in a broad range of concrete resistivity, interfacial resistance and capacitance. Impedance defined in a 4-electrode configuration, when rationalised against the concrete resistivity, is shown to provide, within a realistic range of parameters, a practical mean to access the properties of the bar-concrete interface.

  6. Preschool Personnel Exposure to Occupational Noise

    Directory of Open Access Journals (Sweden)

    Kaļužnaja Darja

    2016-10-01

    Full Text Available Increased noise, which is also below the occupational exposure values and is “hearing safe” noise, affects the exposed person’s health as a non-specific stressor. Increased noise level also creates an environment for additional vocal apparatus load. The objective of this study was to determine preschool personnel occupational noise and its relationship with subjective health complaints. Data were obtained with survey assistance through subjective answers of respondents about health complaints and noise exposure among Rīga preschool personnel. Objective noise measurements were made to assess real noise levels in the preschool environment. Data from 155 respondents and objective measurements of 37 preschool classrooms were obtained. The results showed that the average 8-h noise exposure among Rīga preschool educational institutions was 70 dB(A, which did not exceed the Latvian work environment noise limits, but exceeded the 35–40 dB(A noise limit in the educational environment guidelines recommended by the WHO. The survey results showed that loud noise is one of the most important workplace environmental factors (~70% of respondents feel a necessity to increase voice because of noise. A constant feeling of fatigue, headache, irritable feeling, and a desire to isolate oneself from others more often occurred in respondents exposed to increased noise, compared with those who noted that they were not exposed to increased noise. In general, loud noise was associated with increased subjective health complaints in preschool education institution personnel.

  7. Improvement in the Accuracy of Flux Measurement of Radio Sources by Exploiting an Arithmetic Pattern in Photon Bunching Noise

    Energy Technology Data Exchange (ETDEWEB)

    Lieu, Richard [Department of Physics, University of Alabama, Huntsville, AL 35899 (United States)

    2017-07-20

    A hierarchy of statistics of increasing sophistication and accuracy is proposed to exploit an interesting and fundamental arithmetic structure in the photon bunching noise of incoherent light of large photon occupation number, with the purpose of suppressing the noise and rendering a more reliable and unbiased measurement of the light intensity. The method does not require any new hardware, rather it operates at the software level with the help of high-precision computers to reprocess the intensity time series of the incident light to create a new series with smaller bunching noise coherence length. The ultimate accuracy improvement of this method of flux measurement is limited by the timing resolution of the detector and the photon occupation number of the beam (the higher the photon number the better the performance). The principal application is accuracy improvement in the signal-limited bolometric flux measurement of a radio source.

  8. Improvement in the accuracy of flux measurement of radio sources by exploiting an arithmetic pattern in photon bunching noise

    Science.gov (United States)

    Lieu, Richard

    2018-01-01

    A hierarchy of statistics of increasing sophistication and accuracy is proposed, to exploit an interesting and fundamental arithmetic structure in the photon bunching noise of incoherent light of large photon occupation number, with the purpose of suppressing the noise and rendering a more reliable and unbiased measurement of the light intensity. The method does not require any new hardware, rather it operates at the software level, with the help of high precision computers, to reprocess the intensity time series of the incident light to create a new series with smaller bunching noise coherence length. The ultimate accuracy improvement of this method of flux measurement is limited by the timing resolution of the detector and the photon occupation number of the beam (the higher the photon number the better the performance). The principal application is accuracy improvement in the bolometric flux measurement of a radio source.

  9. Investigation of hydraulic transmission noise sources

    Science.gov (United States)

    Klop, Richard J.

    Advanced hydrostatic transmissions and hydraulic hybrids show potential in new market segments such as commercial vehicles and passenger cars. Such new applications regard low noise generation as a high priority, thus, demanding new quiet hydrostatic transmission designs. In this thesis, the aim is to investigate noise sources of hydrostatic transmissions to discover strategies for designing compact and quiet solutions. A model has been developed to capture the interaction of a pump and motor working in a hydrostatic transmission and to predict overall noise sources. This model allows a designer to compare noise sources for various configurations and to design compact and inherently quiet solutions. The model describes dynamics of the system by coupling lumped parameter pump and motor models with a one-dimensional unsteady compressible transmission line model. The model has been verified with dynamic pressure measurements in the line over a wide operating range for several system structures. Simulation studies were performed illustrating sensitivities of several design variables and the potential of the model to design transmissions with minimal noise sources. A semi-anechoic chamber has been designed and constructed suitable for sound intensity measurements that can be used to derive sound power. Measurements proved the potential to reduce audible noise by predicting and reducing both noise sources. Sound power measurements were conducted on a series hybrid transmission test bench to validate the model and compare predicted noise sources with sound power.

  10. Interior noise analysis of a construction equipment cabin based on airborne and structure-borne noise predictions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hee; Hong, Suk Yoon [Seoul National University, Seoul (Korea, Republic of); Song, Jee Hun [Chonnam National University, Gwangju (Korea, Republic of); Joo, Won Ho [Hyundai Heavy Industries Co. Ltd, Ulsan (Korea, Republic of)

    2012-04-15

    Noise from construction equipment affects not only surrounding residents, but also the operators of the machines. Noise that affects drivers must be evaluated during the preliminary design stage. This paper suggests an interior noise analysis procedure for construction equipment cabins. The analysis procedure, which can be used in the preliminary design stage, was investigated for airborne and structure borne noise. The total interior noise of a cabin was predicted from the airborne noise analysis and structure-borne noise analysis. The analysis procedure consists of four steps: modeling, vibration analysis, acoustic analysis and total interior noise analysis. A mesh model of a cabin for numerical analysis was made at the modeling step. At the vibration analysis step, the mesh model was verified and modal analysis and frequency response analysis are performed. At the acoustic analysis step, the vibration results from the vibration analysis step were used as initial values for radiated noise analysis and noise reduction analysis. Finally, the total cabin interior noise was predicted using the acoustic results from the acoustic analysis step. Each step was applied to a cabin of a middle-sized excavator and verified by comparison with measured data. The cabin interior noise of a middle-sized wheel loader and a large-sized forklift were predicted using the analysis procedure of the four steps and were compared with measured data. The interior noise analysis procedure of construction equipment cabins is expected to be used during the preliminary design stage.

  11. Interior noise analysis of a construction equipment cabin based on airborne and structure-borne noise predictions

    International Nuclear Information System (INIS)

    Kim, Sung Hee; Hong, Suk Yoon; Song, Jee Hun; Joo, Won Ho

    2012-01-01

    Noise from construction equipment affects not only surrounding residents, but also the operators of the machines. Noise that affects drivers must be evaluated during the preliminary design stage. This paper suggests an interior noise analysis procedure for construction equipment cabins. The analysis procedure, which can be used in the preliminary design stage, was investigated for airborne and structure borne noise. The total interior noise of a cabin was predicted from the airborne noise analysis and structure-borne noise analysis. The analysis procedure consists of four steps: modeling, vibration analysis, acoustic analysis and total interior noise analysis. A mesh model of a cabin for numerical analysis was made at the modeling step. At the vibration analysis step, the mesh model was verified and modal analysis and frequency response analysis are performed. At the acoustic analysis step, the vibration results from the vibration analysis step were used as initial values for radiated noise analysis and noise reduction analysis. Finally, the total cabin interior noise was predicted using the acoustic results from the acoustic analysis step. Each step was applied to a cabin of a middle-sized excavator and verified by comparison with measured data. The cabin interior noise of a middle-sized wheel loader and a large-sized forklift were predicted using the analysis procedure of the four steps and were compared with measured data. The interior noise analysis procedure of construction equipment cabins is expected to be used during the preliminary design stage

  12. Random Number Simulations Reveal How Random Noise Affects the Measurements and Graphical Portrayals of Self-Assessed Competency

    Directory of Open Access Journals (Sweden)

    Edward Nuhfer

    2016-01-01

    Full Text Available Self-assessment measures of competency are blends of an authentic self-assessment signal that researchers seek to measure and random disorder or "noise" that accompanies that signal. In this study, we use random number simulations to explore how random noise affects critical aspects of self-assessment investigations: reliability, correlation, critical sample size, and the graphical representations of self-assessment data. We show that graphical conventions common in the self-assessment literature introduce artifacts that invite misinterpretation. Troublesome conventions include: (y minus x vs. (x scatterplots; (y minus x vs. (x column graphs aggregated as quantiles; line charts that display data aggregated as quantiles; and some histograms. Graphical conventions that generate minimal artifacts include scatterplots with a best-fit line that depict (y vs. (x measures (self-assessed competence vs. measured competence plotted by individual participant scores, and (y vs. (x scatterplots of collective average measures of all participants plotted item-by-item. This last graphic convention attenuates noise and improves the definition of the signal. To provide relevant comparisons across varied graphical conventions, we use a single dataset derived from paired measures of 1154 participants' self-assessed competence and demonstrated competence in science literacy. Our results show that different numerical approaches employed in investigating and describing self-assessment accuracy are not equally valid. By modeling this dataset with random numbers, we show how recognizing the varied expressions of randomness in self-assessment data can improve the validity of numeracy-based descriptions of self-assessment.

  13. The effectiveness of environmental strategies on noise reduction in a pediatric intensive care unit: creation of single-patient bedrooms and reducing noise sources.

    Science.gov (United States)

    Kol, Emine; Aydın, Perihan; Dursun, Oguz

    2015-07-01

    Noise is a substantial problem for both patients and healthcare workers in hospitals. This study aimed to determine the effectiveness of environmental strategies (creating single-patient rooms and reducing noise sources) in noise reduction in a pediatric intensive care unit. Noise measurement in the unit was conducted in two phases. In the first phase, measurements aimed at determining the unit's present level of noise were performed over 4 weeks in December 2013. During the month following the first measurement phase, the intensive care unit (ICU) was moved to a new location and noise-reducing strategies were implemented. The second phase, in May 2014, measured noise levels in the newly constructed environment. The noise levels before and after environmental changes were statistically significant at 72.6 dB-A and 56 dB-A, respectively (p noise-reducing strategies can be effective in controlling environmental noise in the ICU. © 2015, Wiley Periodicals, Inc.

  14. Low frequency noise study.

    Science.gov (United States)

    2007-04-01

    This report documents a study to investigate human response to the low-frequency : content of aviation noise, or low-frequency noise (LFN). The study comprised field : measurements and laboratory studies. The major findings were: : 1. Start-of-takeof...

  15. Electrochemical biosensors

    CERN Document Server

    Cosnier, Serge

    2015-01-01

    "This is an excellent book on modern electrochemical biosensors, edited by Professor Cosnier and written by leading international experts. It covers state-of-the-art topics of this important field in a clear and timely manner."-Prof. Joseph Wang, UC San Diego, USA  "This book covers, in 13 well-illustrated chapters, the potential of electrochemical methods intimately combined with a biological component for the assay of various analytes of biological and environmental interest. Particular attention is devoted to the description of electrochemical microtools in close contact with a biological cell for exocytosis monitoring and to the use of nanomaterials in the electrochemical biosensor architecture for signal improvement. Interestingly, one chapter describes the concept and design of self-powered biosensors derived from biofuel cells. Each topic is reviewed by experts very active in the field. This timely book is well suited for providing a good overview of current research trends devoted to electrochemical...

  16. In situ corrosion measurements by electrochemical method (IC experiment) at Mont Terri

    International Nuclear Information System (INIS)

    Dewonck, S.; Bataillon, C.; Crusset, D.; Schwyn, B.; Nakayama, N.; Kwong, G.

    2010-01-01

    Document available in extended abstract form only. The study of the interactions of steel pieces with an argillaceous rock is the aim of the IC experiment carried out in the Mont Terri Rock Laboratory (Switzerland). More precisely, the IC experiment consists in monitoring the corrosion rate of various steel (Inconel 690, 316L stainless steel, 2 carbon steels one representative of Andra concept and another of Nagra concept) at 80 deg. C, in anaerobic condition, in contact with the Opalinus clay formation. The corrosion rate monitoring is based on Electrochemical Impedance Spectroscopy (EIS). This method is not disturbing for the corrosion process i.e. the corrosion rate doesn't change during the electrochemical measurement. The main drawback of this method is that the corrosion process must be in stationary or quasi stationary state: EIS can only measure corrosion rates which do not change quickly with time. This method is well adapted for long term corrosion monitoring because long term corrosion rate evolves slowly. A special design of the experimental setup was developed to allow optimal interactions between rock and steel samples. It consists in mounting the steel samples inside of a bore-core section. This section is then placed at the extremity of the borehole equipment. The equipment is inserted in a vertical descending borehole and sealed by a large packer. Another particularity of the experimental setup is the possibility of heating the experimental section up to 80 deg. C. Finally, the equipment was built in such a way that such that it will be retrievable from the borehole after several years of experiment, in order to perform further analyses on the reacting materials (core and steel samples). A circulation loop links the experimental interval to the sampling, measuring various parameters (pH, Eh, electrical conductivity, dissolved oxygen and hydrogen) and control equipment installed in a cabinet, in the gallery of the underground laboratory. At the

  17. Objective Measures of Listening Effort: Effects of Background Noise and Noise Reduction

    Science.gov (United States)

    Sarampalis, Anastasios; Kalluri, Sridhar; Edwards, Brent; Hafter, Ervin

    2009-01-01

    Purpose: This work is aimed at addressing a seeming contradiction related to the use of noise-reduction (NR) algorithms in hearing aids. The problem is that although some listeners claim a subjective improvement from NR, it has not been shown to improve speech intelligibility, often even making it worse. Method: To address this, the hypothesis…

  18. Measurement of nuclear reactor noise at low power; Merenje nuklearnog reaktorskog suma na malim snagama

    Energy Technology Data Exchange (ETDEWEB)

    Velickovic, Lj [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1968-07-01

    Theoretical interpretation of reactor noise experiments is based on stochastic model developed and described in this paper. Ratio l/{beta} as well as subcriticality level can be determined bu measuring transfer function. In this paper the ratio l/{beta} was determined directly from auto-correlation functions for different critical configurations of the RB zero power reactor core and not by transfer function. This simplified the procedure significantly. It was found that the 0.5 W power level is most suitable for experimental study of neutron fluctuations. In this case fluctuations are intense compared to noise of the detector and electronic devices used.

  19. 1/f noise: diffusive systems and music

    Energy Technology Data Exchange (ETDEWEB)

    Voss, R.F.

    1975-11-01

    Measurements of the 1/f voltage noise in continuous metal films are reported. At room temperature, samples of pure metals and bismuth (with a carrier density smaller by 10/sup 5/) of similar volume had comparable noise. The results suggest that the noise arises from equilibrium temperature fluctuations modulating the resistance. Spatial correlation of the noise implied that the fluctuations obey a diffusion equation. The empirical inclusion of an explicit 1/f region and appropriate normalization lead to excellent agreement with the measured noise. If the fluctuations are assumed to be spatially correlated, the diffusion equation can yield an extended 1/f region in the power spectrum. The temperature response of a sample to delta and step function power inputs is shown to have the same shape as the autocorrelation function for uncorrelated and correlated temperature fluctuations, respectively. The spectrum obtained from the cosine transform of the measured step function response is in excellent agreement with the measured 1/f voltage noise spectrum. Spatially correlated equilibrium temperature fluctuations are not the dominant source of 1/f noise in semiconductors and metal films. However, the agreement between the low-frequency spectrum of fluctuations in the mean-square Johnson noise voltage and the resistance fluctuation spectrum measured in the presence of a current demonstrates that in these systems the 1/f noise is also due to equilibrium resistance fluctuations. Loudness fluctuations in music and speech and pitch fluctuations in music also show the 1/f behavior. 1/f noise sources, consequently, are demonstrated to be the natural choice for stochastic composition. 26 figures, 1 table. (auth)

  20. Attofarad resolution capacitance-voltage measurement of nanometer scale field effect transistors utilizing ambient noise

    International Nuclear Information System (INIS)

    Gokirmak, Ali; Inaltekin, Hazer; Tiwari, Sandip

    2009-01-01

    A high resolution capacitance-voltage (C-V) characterization technique, enabling direct measurement of electronic properties at the nanoscale in devices such as nanowire field effect transistors (FETs) through the use of random fluctuations, is described. The minimum noise level required for achieving sub-aF (10 -18 F) resolution, the leveraging of stochastic resonance, and the effect of higher levels of noise are illustrated through simulations. The non-linear ΔC gate-source/drain -V gate response of FETs is utilized to determine the inversion layer capacitance (C inv ) and carrier mobility. The technique is demonstrated by extracting the carrier concentration and effective electron mobility in a nanoscale Si FET with C inv = 60 aF.