WorldWideScience

Sample records for electrochemical noise analysis

  1. Advantages of Wavelet analysis compared to Fourier analysis for the interpretation of electrochemical noise

    International Nuclear Information System (INIS)

    Espada, L.; Sanjurjo, M.; Urrejola, S.; Bouzada, F.; Rey, G.; Sanchez, A.

    2003-01-01

    Given its simplicity and low cost compared to other types of methodologies, the measurement and interpretation of Electrochemical Noise, is consolidating itself as one of the analysis methods most frequently used for the interpretation of corrosion. As the technique is still evolving, standard treatment methodologies for data retrieved in experiments do not exist yet. To date, statistical analysis and the Fourier analysis are commonly used in order to establish the parameters that may characterize the recording of potential and current electrochemical noise. This study introduces a new methodology based on wavelet analysis and presents its advantages with regards to the Fourier analysis in distinguishes periodical and non-periodical variations in the signal power in time and frequency, as opposed to the Fourier analysis that only considers the frequency. (Author) 15 refs

  2. Electrochemical corrosion potential and noise measurement in high temperature water

    International Nuclear Information System (INIS)

    Fong, Clinton; Chen, Yaw-Ming; Chu, Fang; Huang, Chia-Shen

    2000-01-01

    Hydrogen water chemistry (HWC) is one of the most important methods in boiling water reactor(BWR) system to mitigate and prevent stress corrosion cracking (SCC) problems of stainless steel components. Currently, the effectiveness of HWC in each BWR is mainly evaluated by the measurement of electrochemical corrosion potentials (ECP) and on-line monitoring of SCC behaviors of stainless steels. The objective of this work was to evaluate the characteristics and performance of commercially available high temperature reference electrodes. In addition, SCC monitoring technique based on electrochemical noise analysis (ECN) was also tested to examine its crack detection capability. The experimental work on electrochemical corrosion potential (ECP) measurements reveals that high temperature external Ag/AgCl reference electrode of highly dilute KCl electrolyte can adequately function in both NWC and HWC environments. The high dilution external Ag/AgCl electrode can work in conjunction with internal Ag/AgCl reference electrode, and Pt electrode to ensure the ECP measurement reliability. In simulated BWR environment, the electrochemical noise tests of SCC were carried out with both actively and passively loaded specimens of type 304 stainless steel with various electrode arrangements. From the coupling current and corrosion potential behaviors of the passive loading tests during immersion test, it is difficult to interpret the general state of stress corrosion cracking based on the analytical results of overall current and potential variations, local pulse patterns, statistical characteristics, or power spectral density of electrochemical noise signals. However, more positive SCC indication was observed in the power spectral density analysis. For aqueous environments of high solution impedance, successful application of electrochemical noise technique for SCC monitoring may require further improvement in specimen designs and analytical methods to enhance detection sensitivity

  3. Corrosion detection of carbon steel in water/oil two phases environment by electrochemical noise analysis

    International Nuclear Information System (INIS)

    Gusmano, G.; Montesperelli, G.; De Grandis, A.

    1998-01-01

    The aim of this paper is to demonstrate the effectiveness of the electrochemical noise analysis to detect the onset of corrosion phenomena in a very high resistivity medium. Tests were carried out on carbon steel electrodes immersed in a water/mineral oil two phases environment with high concentration of CO 2 , different aqueous/organic phase ratio, sulphide content between 0 and 0.5 g/l and pH between 1 and 5. The evolution of corrosion phenomena were followed by collecting current and potential noise between three nominally identical electrodes. The noise data were analysed in the time and in the frequency domain. In spite of a great loss of sensitivity of the method with respect to tests performed in aqueous solution, the data indicate a good agreement between the standard deviations and the power level of power spectra density (PSD) of current and potential noise signals and corrosion rates by means of weight loss. The values of the PSD slope, indicate the form of corrosion. The effect of water/oil ratio, sulphide concentration and pH on the corrosion rate was determined. Finally two methods to increase the sensitivity of the electrochemical noise are proposed. (orig.)

  4. Application of spectral analysis of the electrochemical noise to the investigation of aluminium alloy pitting corrosion

    International Nuclear Information System (INIS)

    Bataillon, Christian

    1987-01-01

    The objective of this research is to decode (at least partially) the nature of the information contained in the electrochemical noise associated with the pitting corrosion phenomenon in aluminium alloys. After a general presentation of aluminium and its alloys and a report of a bibliographical study on the electrochemical noise, the author gives an overview of a theoretical approach of stochastic phenomena, and of an experimental approach. Then, the experimental investigation of the electrochemical noise in the case of pitting corrosion leads to a noise control law, to a study of the structure of pitting growth, and to the elaboration of a procedure of assessment of spectral characteristics of this noise. The author reports a systematic study of the electrochemical noise with respect to the parameters of the control law. Results allow a quantitative characterization of pitting corrosion resistance of the studied alloys, notably by using the kinetic aspect of pitting growth and the structure of pitting corrosion. The author discusses the physicochemical nature of random fluctuations which build up the noise. He proposes a more precise explanation of phenomena related to initiation and propagation of pitting corrosion on aluminium alloys in marine environment [fr

  5. Managing Electrochemical Noise Data by Exception Application of an On Line EN Data Analysis Technique to Data From a High Level Nuclear Waste Tank

    International Nuclear Information System (INIS)

    EDGEMON, G.L.

    2003-01-01

    Electrochemical noise has been used a t the Hanford Site for a number of years to monitor in real time for pitting corrosion and stress corrosion cracking (SCC) mechanisms in high level nuclear waste tanks. Currently the monitoring technique has only been implemented on three of the 177 underground storage tanks on the site. Widespread implementation of the technique has been held back for of a number of reasons, including issues around managing the large volume of data associated with electrochemical noise and the complexity of data analysis. Expert review of raw current and potential measurements is the primary form of data analysis currently used at the Hanford site. This paper demonstrates the application of an on-line data filtering and analysis technique that could allow data from field applications of electrochemical noise to be managed by exception, transforming electrochemical noise data into a process parameter and focusing data analysis efforts on the important data. Results of the analysis demonstrate a data compression rate of 95%; that is, only 5% of the data would require expert analysis if such a technique were implemented. It is also demonstrated that this technique is capable of identifying key periods where localized corrosion activity is apparent

  6. Modeling of pH Dependent Electrochemical Noise in Ion Sensitive Field Effect Transistors ISFET

    Directory of Open Access Journals (Sweden)

    M. P. Das

    2013-02-01

    Full Text Available pH ISFETs are very important sensor for in vivo continuous monitoring application of physiological and environmental system. The accuracy of Ion Sensitive Field Effect Transistor (ISFET output measurement is greatly affected by the presences of noise, drift and slow response of the device. Although the noise analysis of ISFET so far performed in different literature relates only to sources originated from Field Effect Transistor (FET structure which are almost constant for a particular device, the pH dependent electrochemical noise has not been substantially explored and analyzed. In this paper we have investigated the low frequency pH dependent electrochemical noise that originates from the ionic conductance of the electrode-electrolyte-Field Effect Transistor structure of the device and that the noise depends on the concentration of the electrolyte and 1/f in nature. The statistical and frequency analysis of this electrochemical noise of a commercial ISFET sensor, under room temperature has been performed for six different pH values ranging from pH2 to pH9.2. We have also proposed a concentration dependent a/f & b/f2 model of the noise with different values of the coefficients a, b.

  7. The use of skewness, kurtosis and neural networks for determining corrosion mechanism from electrochemical noise data

    International Nuclear Information System (INIS)

    Reid, S.; Bell, G.E.C.; Edgemon, G.L.

    1998-01-01

    This paper describes the work undertaken to de-skill the complex procedure of determining corrosion mechanisms derived from electrochemical noise data. The use of neural networks is discussed and applied to the real time generated electrochemical noise data files with the purpose of determining characteristics particular to individual types of corrosion mechanisms. The electrochemical noise signals can have a wide dynamic range and various methods of raw data pre-processing prior to neural network analysis were investigated. Normalized data were ultimately used as input to the final network analysis. Various network schemes were designed, trained and tested. Factors such as the network learning schedule and network design were considered before a final network was implemented to achieve a solution. Neural networks trained using general and localized corrosion data from various material environment systems were used to analyze data from simulated nuclear waste tank environments with favorable results

  8. Electrochemical noise from corroding carbon steel and aluminium

    International Nuclear Information System (INIS)

    Singh, P.R.; Gaonkar, K.B.; De, P.K.; Banerjee, S.

    1997-05-01

    Electrochemical noise measurements were conducted on carbon steel and aluminium in sodium chloride solutions. Noise parameters like standard deviation of potential and current, noise resistance, pitting index, noise power were studied for the purpose of measuring corrosion rate. These parameters compared well with the corrosion rate. Pitting index was not very reliable. Current noise was more close to the corrosion rates. General corrosion gave rise to white noise type of power spectrum while flicker noise type of spectrum was obtained from pitting attack. Sodium nitrite is shown to inhibit the corrosion of carbon steel. Aluminium corrodes in the early period of exposure and passivates during long exposure

  9. Corrosion monitoring in a straw-fired power plant using an electrochemical noise probe

    DEFF Research Database (Denmark)

    Cappeln, Frederik Vilhelm; Bjerrum, Niels; Petrushina, Irina

    2007-01-01

    Electrochemical Noise Measurements have been carried out in situ in a straw-fired power plant using an experimental probe constructed from alumina and AlSl 347 steel. Based on a framework of controlled laboratory experiments it has been found that electrochemical noise has the unique ability...... to provide in-situ monitoring of intergranular corrosion in progress. The probe had a lifetime of two months. It was shown that down-time corrosion in the boiler was negligible. Electrochemical noise data indicated that metal temperatures around 590 degrees C should be avoided as the intergranular corrosion...

  10. A study of passivation/depassivation of carbon steel; electrochemical impedance spectrocopy vs. potential noise fluctuations

    International Nuclear Information System (INIS)

    Roberge, P.R.; Halliop, E.; Sastri, V.S.

    1992-01-01

    A technique based on recording corrosion potential fluctuations generated by corroding electrodes was used under open-circuit conditions to study passivation and depassivation of carbon steel. Quantification of the electrochemical signal in terms of the pitting corrosion rate has been attempted. The amplitude of electrochemical noise signals was analyzed under different pitting conditions and correlated to polarization resistance values obtained from the electrochemical impedance spectra. The automatic statistical data analysis of electrochemical impedance data points has been successfully applied to calculate polarization resistance values and other interesting characteristics of such measurements

  11. Analysis of electrochemical noise (ECN) data in time and frequency domain for comparison corrosion inhibition of some azole compounds on Cu in 1.0 M H2SO4 solution

    Science.gov (United States)

    Ramezanzadeh, B.; Arman, S. Y.; Mehdipour, M.; Markhali, B. P.

    2014-01-01

    In this study, the corrosion inhibition properties of two similar heterocyclic compounds namely benzotriazole (BTA) and benzothiazole (BNS) inhibitors on copper in 1.0 M H2SO4 solution were studied by electrochemical techniques as well as surface analysis. The results showed that corrosion inhibition of copper largely depends on the molecular structure and concentration of the inhibitors. The effect of DC trend on the interpretation of electrochemical noise (ECN) results in time domain was evaluated by moving average removal (MAR) method. Accordingly, the impact of square and Hanning window functions as drift removal methods in frequency domain was studied. After DC trend removal, a good trend was observed between electrochemical noise (ECN) data and the results obtained from EIS and potentiodynamic polarization. Furthermore, the shot noise theory in frequency domain was applied to approach the charge of each electrochemical event (q) from the potential and current noise signals.

  12. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  13. Electrochemical Noise Chaotic Analysis of NiCoAg Alloy in Hank Solution

    Directory of Open Access Journals (Sweden)

    D. Bahena

    2011-01-01

    Full Text Available The potential and current oscillations during corrosion of NiCoAg alloy in Hank solution were studied. Detailed nonlinear fractal analyses were used to characterize complex time series clearly showing that the irregularity in these time series corresponds to deterministic chaos rather than to random noise. The chaotic oscillations were characterized by power spectral densities, phase space, and Lyapunov exponents. Electrochemical impedance was also applied the fractal dimensions for the corroded surface was obtained, and a corrosion mechanism was proposed.

  14. In situ characterization of natural pyrite bioleaching using electrochemical noise technique

    Science.gov (United States)

    Chen, Guo-bao; Yang, Hong-ying; Li, Hai-jun

    2016-02-01

    An in situ characterization technique called electrochemical noise (ECN) was used to investigate the bioleaching of natural pyrite. ECN experiments were conducted in four active systems (sulfuric acid, ferric-ion, 9k culture medium, and bioleaching solutions). The ECN data were analyzed in both the time and frequency domains. Spectral noise impedance spectra obtained from power spectral density (PSD) plots for different systems were compared. A reaction mechanism was also proposed on the basis of the experimental data analysis. The bioleaching system exhibits the lowest noise resistance of 0.101 MΩ. The bioleaching of natural pyrite is considered to be a bio-battery reaction, which distinguishes it from chemical oxidation reactions in ferric-ion and culture-medium (9k) solutions. The corrosion of pyrite becomes more severe over time after the long-term testing of bioleaching.

  15. Comparison of susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys in neutral chloride solutions using electrochemical noise analysis

    International Nuclear Information System (INIS)

    Na, Kyung-Hwan; Pyun, Su-Il

    2008-01-01

    The susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys was investigated in aqueous neutral chloride solution for the purpose of comparison using electrochemical noise measurement. The experimentally measured electrochemical noises were analysed based upon the combined stochastic theory and shot-noise theory using the Weibull distribution function. From the occurrence of two linear regions on one Weibull probability plot, it was suggested that there existed two stochastic processes of uniform corrosion and pitting corrosion; pitting corrosion was distinguished from uniform corrosion in terms of the frequency of events in the stochastic analysis. Accordingly, the present analysis method allowed us to investigate pitting corrosion independently. The susceptibility to pitting corrosion was appropriately evaluated by determining pit embryo formation rate in the stochastic analysis. The susceptibility was decreased in the following order: AA2024-T4 (the naturally aged condition), AA7475-T761 (the overaged condition) and AA7075-T651 (the near-peak-aged condition)

  16. Destructive impact of molecular noise on nanoscale electrochemical oscillators

    Science.gov (United States)

    Cosi, Filippo G.; Krischer, Katharina

    2017-06-01

    We study the loss of coherence of electrochemical oscillations on meso- and nanosized electrodes with numeric simulations of the electrochemical master equation for a prototypical electrochemical oscillator, the hydrogen peroxide reduction on Pt electrodes in the presence of halides. On nanoelectrodes, the electrode potential changes whenever a stochastic electron-transfer event takes place. Electrochemical reaction rate coefficients depend exponentially on the electrode potential and become thus fluctuating quantities as well. Therefore, also the transition rates between system states become time-dependent which constitutes a fundamental difference to purely chemical nanoscale oscillators. Three implications are demonstrated: (a) oscillations and steady states shift in phase space with decreasing system size, thereby also decreasing considerably the oscillating parameter regions; (b) the minimal number of molecules necessary to support correlated oscillations is more than 10 times as large as for nanoscale chemical oscillators; (c) the relation between correlation time and variance of the period of the oscillations predicted for chemical oscillators in the weak noise limit is only fulfilled in a very restricted parameter range for the electrochemical nano-oscillator.

  17. Corrosion monitoring of the AA2024 alloy in NaCl solutions by electrochemical noise measurements

    International Nuclear Information System (INIS)

    Aballe, A.; Bethencourt, M.; Botana, F.J.; Marcos, M.; Rodriguez-Chacon, M.A.

    1998-01-01

    The behaviour of the AA2024 alloy against corrosion in 3.5% NaCl solution has been monitored. In this environment the alloy can be easily damaged under small anodic polarizations. Linear Polarization, electrochemical impedance, spectroscopy and electrochemical noise measurement have been used as experimental techniques. Data from ENM have been analyzed using statistical parameters and Chaos Theory. The results here obtained suggest that ENM is particularly useful to monitored systems that can be modified using other electrochemical techniques. (Author) 11 refs

  18. Problems, pitfalls, and probes: Welcome to the jungle of electrochemical noise technology

    International Nuclear Information System (INIS)

    Edgemon, G.L.

    1998-01-01

    The rise in electrochemical noise (EN) as a corrosion monitoring technique has resulted in unique problems associated with the field application of this method. Many issues relate to the design of the EN probe electrodes. The ability of an electrochemical noise monitoring system to identify and discriminate between localized corrosion mechanisms is related primarily to the capability of the probe to separate the corrosion cell anode from the corresponding cathode. Effectiveness of this separation is largely determined by the details of and the proper design of the probe that is in the environment of interest. No single probe design or geometry can be effectively use in every situation to monitor all types of corrosion. In this paper the authors focus on a case study and probe development history related to monitoring corrosion in an extremely hostile environment using EN. While the ultimate application of EN was and continues to be successful, the case study shows that patience and persistence was necessary to meet and properly implement the monitoring program. Other possible source of problems and frustration with implementing EN are also discussed

  19. Electrochemical noise measurements of steel corrosion in the molten NaCl-K2SO4 system

    DEFF Research Database (Denmark)

    Cappeln, Frederik Vilhelm; Bjerrum, Niels; Petrushina, Irina

    2005-01-01

    -called active corrosion (i.e., the corrosion proceeds with no passivation due to the influence of chlorine), characterized by the formation of volatile metal chlorides as a primary corrosion product. It was found possible to obtain an empirical separation of general and intergranular corrosion using kurtosis (a......Electrochemical noise measurements have been carried out on AISI347, 10CrMo910, 15Mo3, and X20CrMoV121 steels in molten NaCl-K2SO4 at 630 degrees C. Different types of current noise have been identified for pitting, intergranular and peeling corrosion. The corrosion mechanism was the so...... statistical parameter calculated from the electrochemical noise data). It was found that average kurtosis values above 6 indicated intergranular corrosion and average values below 6 indicated general corrosion. The response time for localized corrosion detection in in-plant monitoring was approximately 90 min...

  20. Electrochemical noise evaluation of anodized aluminum. Comparative study against corrosion behaviour in the atmosphere

    International Nuclear Information System (INIS)

    Betancourt, N.; Corvo, F.; Mendoza, A.; Simancas, J.; Morcillo, M.; Gonzalez, J. A.; Fragata, F.; Pena, J. J.; Sanchez de Villalaz, M.; Flores, S.; Almeida, E.; Rivero, S.; Rincon, O. T. de.

    2003-01-01

    The present work reports the evaluation of aluminum and anodized aluminum by electrochemical noise, as a part of the PATINE/CYTED project of the working group NS5. A visual examination is also made. The samples were exposed at several Ibero-American atmospheres up to 2 years of exposure. Different thickness of anodized aluminum were evaluated. The electrochemical potential noise of the 5 μm unexposed sample (pattern) showed a different behaviour to that showed by the other anodized specimens. This could be due to a slower sealed of the samples of higher thickness. The same behavior was observed on the samples exposed at the rural station. el Pardo. According to the visual examination, the samples of bare aluminum and those of anodized 5 μm thickness were the most affected by pitting corrosion in the highly polluted atmospheres. A good correlation between corrosion behaviour determined by visual examination and EN was obtained. (Author) 4 refs

  1. Detection of localized and general corrosion of mild steel in simulated defense nuclear waste solutions using electrochemical noise analysis

    International Nuclear Information System (INIS)

    Edgemon, G.L.; Ohl, P.C.; Bell, G.E.C.; Wilson, D.F.

    1995-12-01

    Underground waste tanks fabricated from mild steel store more than 60 million gallons of radioactive waste from 50 years of weapons production. Leaks are suspected in a significant number of tanks. The probable modes of corrosion failures are reported to be localized corrosion (e.g. nitrate stress corrosion cracking and pitting). The use of electrochemical noise (EN) for the monitoring and detection of localized corrosion processes has received considerable attention and application over the last several years. Proof of principle laboratory tests were conducted to verify the capability of EN evaluation to detect localized corrosion and to compare the predictions of general corrosion obtained from EN with those derived from other sources. Simple, pre-fabricated flat and U-bend specimens of steel alloys A516-Grade 60 (UNS K02100) and A537-CL 1 (UNS K02400) were immersed in temperature controlled simulated waste solutions. The simulated waste solution was either 5M NaNO 3 with 0.3M NaOH at 90 C or 11M NaNO 3 with 0.15M NaOH at 95 C. The electrochemical noise activity from the specimens was monitored and recorded for periods ranging between 140 and 240 hours. At the end of each test period, the specimens were metallographically examined to correlated EN data with corrosion damage

  2. Electrochemical noise transient analysis for 316 and Duplex 2205 stainless steels in NaCl and FeCl; Analisis de los transitorios de ruido electroquimico para aceros inoxidables 316 Y - DUPLEX 2205 en NaCl Y FeCl

    Energy Technology Data Exchange (ETDEWEB)

    Almeraya-Calderaon, F.; Estupinan, F.; Zambrano, P.; Martinez-Villafane, A.; Borunda, A.; Colas, R.; Gaona-Tiburcio, C.

    2012-11-01

    This work shows the results obtained from electrochemical noise measurements for different materials exhibiting pitting corrosion. The transients presented in the potential and current time, correlates with the scanning electron microscopy (SEM) surface analysis. Electrochemical measurements were made at different exposure times to obtain the correlation. The materials used were stainless steel austenitic 316 and duplex 2205, immersed in ferric chloride (FeCl3) and sodium chloride (NaCl) electrolytes. SEM analysis shows that the transients observed in the time series, really correspond to the activity of pit nucleation developed over the surface of the electrodes. (Author) 31 refs.

  3. Electrochemical analysis

    International Nuclear Information System (INIS)

    Hwang, Hun

    2007-02-01

    This book explains potentiometry, voltametry, amperometry and basic conception of conductometry with eleven chapters. It gives the specific descriptions on electrochemical cell and its mode, basic conception of electrochemical analysis on oxidation-reduction reaction, standard electrode potential, formal potential, faradaic current and faradaic process, mass transfer and overvoltage, potentiometry and indirect potentiometry, polarography with TAST, normal pulse and deferential pulse, voltammetry, conductometry and conductometric titration.

  4. Application of a passive electrochemical noise technique to localized corrosion of candidate radioactive waste container materials

    International Nuclear Information System (INIS)

    Korzan, M.A.

    1994-05-01

    One of the key engineered barriers in the design of the proposed Yucca Mountain repository is the waste canister that encapsulates the spent fuel elements. Current candidate metals for the canisters to be emplaced at Yucca Mountain include cast iron, carbon steel, Incoloy 825 and titanium code-12. This project was designed to evaluate passive electrochemical noise techniques for measuring pitting and corrosion characteristics of candidate materials under prototypical repository conditions. Experimental techniques were also developed and optimized for measurements in a radiation environment. These techniques provide a new method for understanding material response to environmental effects (i.e., gamma radiation, temperature, solution chemistry) through the measurement of electrochemical noise generated during the corrosion of the metal surface. In addition, because of the passive nature of the measurement the technique could offer a means of in-situ monitoring of barrier performance

  5. A Plan to Develop and Demonstrate Electrochemical Noise Based Corrosion Monitoring Systems in Hanford Site Waste Tanks

    International Nuclear Information System (INIS)

    NORMAN, E.C.

    2000-01-01

    This document describes changes that need to be made to the site's authorization basis and technical concerns that need to be resolved before proceduralized use of Electrochemical Noise based corrosion monitoring systems is fully possible at the Hanford Site

  6. Measurement of electrochemical noise for the study of corrosion processes of metallic alloys; Medida de ruido electroquimico para el estudio de rocesoso de corrosion de aleaciones metalicas

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Amaya, J. M.; Bethencourt, M.; Gonzalez-Rovira, L.; Botana, F. J.

    2009-07-01

    Electrochemical noise (EN) is a technique that allows the estimation of both the rate and the corrosion mechanism of different metallic alloys by means of the measurement and the analysis of the fluctuations of current and voltage. Its main advantage against other electrochemical techniques is that during the measurement process, the corrosive systems under study are not instrumentally disturbed, and therefore, the systems are kept at their natural corrosion potential. Two steps are necessary to use this technique: measurement and analysis of the EN signals. In this paper, the most important concepts related only to the measurement of EN are revised. The parameters most employed in the literature to analyse the EN signals will be described in another paper. In the present article, the experimental devices normally used to measure EN signals are firstly analysed. Subsequently, the most important properties of the EN signals are studied. Finally, the external sources of instrumental noise that can affect to the EN signals are described. (Author) 65 refs.

  7. Electrochemical Sensors for Clinic Analysis

    Directory of Open Access Journals (Sweden)

    Guang Li

    2008-03-01

    Full Text Available Demanded by modern medical diagnosis, advances in microfabrication technology have led to the development of fast, sensitive and selective electrochemical sensors for clinic analysis. This review addresses the principles behind electrochemical sensor design and fabrication, and introduces recent progress in the application of electrochemical sensors to analysis of clinical chemicals such as blood gases, electrolytes, metabolites, DNA and antibodies, including basic and applied research. Miniaturized commercial electrochemical biosensors will form the basis of inexpensive and easy to use devices for acquiring chemical information to bring sophisticated analytical capabilities to the non-specialist and general public alike in the future.

  8. Service water electrochemical monitoring development at Ontario Hydro

    International Nuclear Information System (INIS)

    Brennenstuhl, A.M.

    1994-01-01

    Ontario Hydro (OH) is currently investigating the feasibility of using electrochemical techniques for the corrosion monitoring of service water systems. To date all evaluations have been carried out in a field simulator. The studies include examining the effects of; system startup after periods of stagnation, sodium hypochlorite injection, and zebra mussel settlement on metallic surfaces. Carbon steel and Type 304L stainless steel have been evaluated. Electrochemical potential noise (EPN), electrochemical current noise (ECN) potential and coupling current were semi-continuously monitored over a period of up to one year. Data obtained from the electrochemical noise monitoring has given OH valuable insights into the mechanisms of degradation in service water systems. The high sensitivity of the electrochemical noise technique, particularly to localized corrosion has proved to be the major attraction of the system

  9. Electrochemical noise measurements techniques and the reversing dc potential drop method applied to stress corrosion essays

    International Nuclear Information System (INIS)

    Aly, Omar Fernandes; Andrade, Arnaldo Paes de; MattarNeto, Miguel; Aoki, Idalina Vieira

    2002-01-01

    This paper aims to collect information and to discuss the electrochemical noise measurements and the reversing dc potential drop method, applied to stress corrosion essays that can be used to evaluate the nucleation and the increase of stress corrosion cracking in Alloy 600 and/or Alloy 182 specimens from Angra I Nuclear Power Plant. Therefore we will pretend to establish a standard procedure to essays to be realized on the new autoclave equipment on the Laboratorio de Eletroquimica e Corrosao do Departamento de Engenharia Quimica da Escola Politecnica da Universidade de Sao Paulo - Electrochemical and Corrosion Laboratory of the Chemical Engineering Department of Polytechnical School of Sao Paulo University, Brazil. (author)

  10. Corrosion initiation of stainless steel in HCl solution studied using electrochemical noise and in-situ atomic force microscope

    International Nuclear Information System (INIS)

    Li Yan; Hu Ronggang; Wang Jingrun; Huang Yongxia; Lin Changjian

    2009-01-01

    An in-situ atomic force microscope (AFM), optical microscope and electrochemical noise (ECN) techniques were applied to the investigation of corrosion initiations in an early stage of 1Cr18Ni9Ti stainless steel immersed in 0.5 M HCl solution. The electrochemical current noise data has been analyzed using discrete wavelet transform (DWT). For the first time, the origin of wavelet coefficients is discussed based on the correlation between the evolution of the energy distribution plot (EDP) of wavelet coefficients and topographic changes. It is found that the occurrence of initiation of metastable pitting at susceptive sites is resulted from the reductive breakdown of passive film of stainless steel in the diluted HCL solution. The coefficients d 4 -d 6 are originated from metastable pitting, d 7 represents the formation and growth of stable pitting while d 8 corresponds to the general corrosion.

  11. Electrochemical noise of the erosion-corrosion of copper in relation with its hydrodynamic parameters; Ruido electroquimico de la erosion-corrosion en cobre: su relacion con los parametros hidrodinamicos

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, I.; Romero, M.; Malo, J.M.; Uruchurtu, J.

    2010-07-01

    This work presents the electrochemical noise results obtained of the surface degradation on copper, due to erosion corrosion phenomena, which were a function of the hydrodynamic parameters of the system (fluid movement). A modified rotating cylinder (RC) comprising three ring electrodes under two rotating speeds (880 and 1750 rpm with a Reynolds numbers 1486 Re and 2972 Re, respectively) were used. Characteristic electrochemical noise spectra as a function of the hydrodynamic parameters were found, as well as surface attack intensities the noise signal. An increase and a more uniform attack due to particle impact was related to larger particle size and lesser erosion corrosion intensity, in the form of more localized attack over the surface, was obtained for smaller ones. Erosion corrosion attack presents characteristic electrochemical current and potential noise signals, according to the laminar or transitional turbulent regime and particle size added. (Author).

  12. Treatment of electrochemical noise data by the Hilbert-Huang transform

    International Nuclear Information System (INIS)

    Rahier, A.

    2009-01-01

    Most of the classical approaches for treating electro-chemical noise (ECN) data suffer from the non-linear and non steady-state character of the delivered signal. Very often, the link between time and the local corrosion events supposedly responsible for ECN data signatures is lost during treatment, as is obvious when using the classical Fourier Transform (FT), followed by an analysis of the response in the frequency domain. In this particular case, the information directly related to the corrosion events is distributed into the full spectra, thereby preventing the operator to derive clear and precise conclusions. In 2005, we suggested an alternative data treatment based on the Hilbert-Huang transform (HHT). The latter keeps track of the time variable and copes with non-linear and non steady-state behaviours of the system under examination. In 2006, we demonstrated the applicability of the newly proposed data treatment in the case of ECN data collected under BWR (Boiling Water Reactor) conditions. In 2007, we collected additional ECN data and started a preliminary investigation of two mathematical restrictions that are susceptible to impair the interpretation of the results. We discovered a possible modification of the Hilbert transform allowing generating controlled phase shifts that are different from pi/2 as is always the case for the Hilbert transform

  13. In situ synthesis, electrochemical and quantum chemical analysis of an amino acid-derived ionic liquid inhibitor for corrosion protection of mild steel in 1M HCl solution

    International Nuclear Information System (INIS)

    Kowsari, E.; Arman, S.Y.; Shahini, M.H.; Zandi, H.; Ehsani, A.; Naderi, R.; PourghasemiHanza, A.; Mehdipour, M.

    2016-01-01

    Highlights: • Electrochemical analysis of effectiveness of an amino acid-derived ionic liquid inhibitor. • Quantum chemical analysis of effectiveness of an amino acid-derived ionic liquid inhibitor. • Finding correlation between electrochemical analysis and quantum chemical analysis. - Abstract: In this study, an amino acid-derived ionic liquid inhibitor, namely tetra-n-butyl ammonium methioninate, was synthesized and the role this inhibitor for corrosion protection of mild steel exposed to 1.0 M HCl was investigated using electrochemical, quantum and surface analysis. By taking advantage of potentiodynamic polarization, the inhibitory action of tetra-n-butyl ammonium methioninate was found to be mainly mixed-type with dominant anodic inhibition. The effectiveness of the inhibitor was also indicated using electrochemical impedance spectroscopy (EIS). Moreover, to provide further insight into the mechanism of inhibition, electrochemical noise (EN) and quantum chemical calculations of the inhibitor were performed.

  14. A state of the art on electrochemical noise technique. Assessment of corrosion characteristics and development of remedial technology in nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jin; Kim, Joung Soo; Kim, Hong Pyo; Lim, Yun Soo; Yi, Yong Sun; Chung, Man Kyo

    2003-02-01

    The studies for the application of electrochemical noise technique were reviewed in terms of principle, analysing method and application examples of this technique. Because 4% of the economic damage of industry is caused by metallic corrosion, it is important to find and protect corrosive materials and location. By corrosion monitoring of industrial facilities such as nuclear power plant using Electrochemical Noise Measurement(ENM), corrosion attack can be detected and furthermore it can be indicated whether the attacked materials is replaced by new one or not. According to development of control and electronic technology, it was easy to apply ENM to the industry and the interest in ENM also increased. As corrosion is produced on a metal under corrosive environment, local anode(oxidation) and cathode(reduction) are formed. Hence, there is potential difference and current flow between the anode and cathode. ENM is monitoring the potential difference and the current flow with time by high impedance load voltmeter and Zero Resistance Ammeter(ZRA), respectively. The potential difference and current flow generated spontaneously without any application of current and potential between electrodes are monitored by electrochemical noise technique, Thereby ENM can be regarded as the most ideal corrosion monitoring method for the industrial facility and nuclear power plant having corrosion damage and difficulty in access of human body. Moreover, it is possible to obtain the spontaneous and reliable results from the metals damaged by ununiform and localized corrosion such as pitting and SCC using ENM while it is difficult to obtain the reliable result using traditional linear polarization and ac-impedance measurement. In many countries, there are extensive works concerned with application of electrochemical noise technique to corrosion monitoring of nuclear power plant and other industrial facilities, whereas there is little work on this field in Korea. Systematic study for

  15. Noise resistance applied to the study of zinc rich paints

    International Nuclear Information System (INIS)

    Espada Recarey, L.; Sanchez Bermudez, A.; Urrejola Madrinan, S.; Bouzada Alvela, F.

    2001-01-01

    Electrochemical Noise has been one of the more useful analysis methods to the study the corrosion processes due to the fact that it is simple and cheap. The objective of this work is to check the efficiency of this technique when it is applied to the study of Rich Zinc Paints and specifically the Noise Resistance parameter which is very efficiency to study metal-electrolyte systems. Then this technique was applied to Rich Zinc Paints systems of which we have already information by means of electrochemical impedance spectroscopy. The outcomes of this paper show the efficiency of applying Noise Resistance technique to explain the behavior of this kind of systems. (Author) 18 refs

  16. Electrochemical noise and impedance of Au electrode/electrolyte interfaces enabling extracellular detection of glioma cell populations.

    Science.gov (United States)

    Rocha, Paulo R F; Schlett, Paul; Kintzel, Ulrike; Mailänder, Volker; Vandamme, Lode K J; Zeck, Gunther; Gomes, Henrique L; Biscarini, Fabio; de Leeuw, Dago M

    2016-10-06

    Microelectrode arrays (MEA) record extracellular local field potentials of cells adhered to the electrodes. A disadvantage is the limited signal-to-noise ratio. The state-of-the-art background noise level is about 10 μVpp. Furthermore, in MEAs low frequency events are filtered out. Here, we quantitatively analyze Au electrode/electrolyte interfaces with impedance spectroscopy and noise measurements. The equivalent circuit is the charge transfer resistance in parallel with a constant phase element that describes the double layer capacitance, in series with a spreading resistance. This equivalent circuit leads to a Maxwell-Wagner relaxation frequency, the value of which is determined as a function of electrode area and molarity of an aqueous KCl electrolyte solution. The electrochemical voltage and current noise is measured as a function of electrode area and frequency and follow unambiguously from the measured impedance. By using large area electrodes the noise floor can be as low as 0.3 μVpp. The resulting high sensitivity is demonstrated by the extracellular detection of C6 glioma cell populations. Their minute electrical activity can be clearly detected at a frequency below about 10 Hz, which shows that the methodology can be used to monitor slow cooperative biological signals in cell populations.

  17. Integrating Electrochemical Detection with Centrifugal Microfluidics for Real-Time and Fully Automated Sample Testing

    DEFF Research Database (Denmark)

    Andreasen, Sune Zoëga; Kwasny, Dorota; Amato, Letizia

    2015-01-01

    Here we present a robust, stable and low-noise experimental set-up for performing electrochemical detection on a centrifugal microfluidic platform. By using a low-noise electronic component (electrical slip-ring) it is possible to achieve continuous, on-line monitoring of electrochemical experime......Here we present a robust, stable and low-noise experimental set-up for performing electrochemical detection on a centrifugal microfluidic platform. By using a low-noise electronic component (electrical slip-ring) it is possible to achieve continuous, on-line monitoring of electrochemical...

  18. Electrochemical noise based corrosion monitoring: FY 2001 final report

    International Nuclear Information System (INIS)

    EDGAR, C.

    2001-01-01

    Underground storage tanks made of mild steel are used to contain radioactive waste generated by plutonium production at the Hanford Site. Corrosion of the walls of these tanks is a major issue. Corrosion monitoring and control are currently provided at the Hanford Site through a waste chemistry sampling and analysis program. In this process, tank waste is sampled, analyzed and compared to a selection of laboratory exposures of coupons in simulated waste. Tank wall corrosion is inferred by matching measured tank chemistries to the results of the laboratory simulant testing. This method is expensive, time consuming, and does not yield real-time data. Corrosion can be monitored through coupon exposure studies and a variety of electrochemical techniques. A small number of these techniques have been tried at Hanford and elsewhere within the DOE complex to determine the corrosivity of nuclear waste stored in underground tanks [1]. Coupon exposure programs, linear polarization resistance (LPR), and electrical resistance techniques have all been tried with limited degrees of success. These techniques are most effective for monitoring uniform corrosion, but are not well suited for early detection of localized forms of corrosion such as pitting and stress corrosion cracking (SCC). Pitting and SCC have been identified as the most likely modes of corrosion failure for Hanford Double Shell Tanks (DST'S) [2-3]. Over the last 20 years, a new corrosion monitoring system has shown promise in detecting localized corrosion and measuring uniform corrosion rates in process industries [4-20]. The system measures electrochemical noise (EN) generated by corrosion. The term EN is used to describe low frequency fluctuations in current and voltage associated with corrosion. In their most basic form, EN-based corrosion monitoring systems monitor and record fluctuations in current and voltage over time from electrodes immersed in an environment of interest. Laboratory studies and field

  19. Noise and vibration analysis system

    International Nuclear Information System (INIS)

    Johnsen, J.R.; Williams, R.L.

    1985-01-01

    The analysis of noise and vibration data from an operating nuclear plant can provide valuable information that can identify and characterize abnormal conditions. Existing plant monitoring equipment, such as loose parts monitoring systems (LPMS) and neutron flux detectors, may be capable of gathering noise data, but may lack the analytical capability to extract useful meanings hidden in the noise. By analyzing neutron noise signals, the structural motion and integrity of core components can be assessed. Computer analysis makes trending of frequency spectra within a fuel cycle and from one cycle to another a practical means of core internals monitoring. The Babcock and Wilcox Noise and Vibration Analysis System (NVAS) is a powerful, compact system that can automatically perform complex data analysis. The system can acquire, process, and store data, then produce report-quality plots of the important parameter. Software to perform neutron noise analysis and loose parts analysis operates on the same hardware package. Since the system is compact, inexpensive, and easy to operate, it allows utilities to perform more frequency analyses without incurring high costs and provides immediate results

  20. BWR noise spectra and application of noise analysis to FBR

    International Nuclear Information System (INIS)

    Nomura, T.

    1975-01-01

    Work related to noise analysis, in Tokyo Shibaura Electric Co. Ltd. (Toshiba) and Nippon Atomic Industry Group Co. Ltd. (NAIG) for the past several years is reviewed. After considering the Japan-United States Seminar on Reactor Noise Analysis in 1968, other subjects discussed were boiling water reactor noise analysis and work in relation to FBR. Parts of these are related to each other. For example, boiling detection and temperature fluctuations are problems pertinent to both fields. As the main problems in zero-power-reactor noise are now basically understood, only a brief description of the experiments involving the advanced two detector method is made. Focus is rather placed on the area of power plant noise. (author)

  1. Detection of crevice corrosion in AISI type 316LN stainless steel in presence of pseudomonas bacteria using electrochemical noise technique

    International Nuclear Information System (INIS)

    Pujar, M.G.; George, R.P.; Ramya, S.; Kamachi Mudali, U.

    2011-01-01

    Gram-negative pseudomonas sp. was used as the test organism for the biofilm formation and growth on 316 LN stainless and electrochemical noise (EN) monitoring studies, since this genus has been identified as the major biofilm former on stainless steels. EN studies were conducted for 21 days on the galvanically coupled specimens exposed to the dilute nutrient culture with pseudomonas sp. The visual records of the current potential EN, analysis of statistical and power spectral density (PSD) parameters of current and potential along with shot-noise parameters showed increase in the localized corrosion during initial 2-11 days exposure; thereafter the specimens showed passive behaviour. Raman spectra taken inside the pit for the specimen exposed for 21 days showed the peak corresponding to Cr 3+ ions signifying repassivation process. Similarly, Raman spectra on the surface outside the pits on the specimens exposed for 7, 10 and 15 days showed steady growth of the peak corresponding to Cr 3+ ions. This implied steady enrichment of Cr on the surface of the specimen which accounted for the gradual passivation with increased exposure time. (author)

  2. Statistical analysis of electrochemical noise records at aluminium corrosion; Analisis estadistico de los registros de ruido electroquimico obtenidos en la corrosion del aluminio

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, A.; Sanjurjo, M.; Bouzada, F.; Urrejola, S.

    2005-07-01

    Given that the experimental signals obtained in an electrochemical noise measurement, ENM, are recorded over a discrete time period, the most direct way of analysing them will be in the time domain resorting to starting to statistical methods. These can be classified into two groups according to use; those which attempt to quantify the degree of the corrosion process (standard deviations, statistical power); and those which attempt to provide information on the corrosion mechanism (based on the assumption that the shape of the time records is a reflection of itself). Among the later the use of the average, the skewness and the kurtosis of the signals or the pitting index can be pointed out as being able to reflect the changes in the corrosion mechanism. Noise resistance stands out above all these parameters. In this work has undertaken the statistical treatment of ENM data obtained by subjecting aluminium to three electrolytes that provoke several types of corrosion in it: passivity, pitting corrosion and generalized corrosion. (Author) 22 refs.

  3. Interior noise analysis of a construction equipment cabin based on airborne and structure-borne noise predictions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hee; Hong, Suk Yoon [Seoul National University, Seoul (Korea, Republic of); Song, Jee Hun [Chonnam National University, Gwangju (Korea, Republic of); Joo, Won Ho [Hyundai Heavy Industries Co. Ltd, Ulsan (Korea, Republic of)

    2012-04-15

    Noise from construction equipment affects not only surrounding residents, but also the operators of the machines. Noise that affects drivers must be evaluated during the preliminary design stage. This paper suggests an interior noise analysis procedure for construction equipment cabins. The analysis procedure, which can be used in the preliminary design stage, was investigated for airborne and structure borne noise. The total interior noise of a cabin was predicted from the airborne noise analysis and structure-borne noise analysis. The analysis procedure consists of four steps: modeling, vibration analysis, acoustic analysis and total interior noise analysis. A mesh model of a cabin for numerical analysis was made at the modeling step. At the vibration analysis step, the mesh model was verified and modal analysis and frequency response analysis are performed. At the acoustic analysis step, the vibration results from the vibration analysis step were used as initial values for radiated noise analysis and noise reduction analysis. Finally, the total cabin interior noise was predicted using the acoustic results from the acoustic analysis step. Each step was applied to a cabin of a middle-sized excavator and verified by comparison with measured data. The cabin interior noise of a middle-sized wheel loader and a large-sized forklift were predicted using the analysis procedure of the four steps and were compared with measured data. The interior noise analysis procedure of construction equipment cabins is expected to be used during the preliminary design stage.

  4. Interior noise analysis of a construction equipment cabin based on airborne and structure-borne noise predictions

    International Nuclear Information System (INIS)

    Kim, Sung Hee; Hong, Suk Yoon; Song, Jee Hun; Joo, Won Ho

    2012-01-01

    Noise from construction equipment affects not only surrounding residents, but also the operators of the machines. Noise that affects drivers must be evaluated during the preliminary design stage. This paper suggests an interior noise analysis procedure for construction equipment cabins. The analysis procedure, which can be used in the preliminary design stage, was investigated for airborne and structure borne noise. The total interior noise of a cabin was predicted from the airborne noise analysis and structure-borne noise analysis. The analysis procedure consists of four steps: modeling, vibration analysis, acoustic analysis and total interior noise analysis. A mesh model of a cabin for numerical analysis was made at the modeling step. At the vibration analysis step, the mesh model was verified and modal analysis and frequency response analysis are performed. At the acoustic analysis step, the vibration results from the vibration analysis step were used as initial values for radiated noise analysis and noise reduction analysis. Finally, the total cabin interior noise was predicted using the acoustic results from the acoustic analysis step. Each step was applied to a cabin of a middle-sized excavator and verified by comparison with measured data. The cabin interior noise of a middle-sized wheel loader and a large-sized forklift were predicted using the analysis procedure of the four steps and were compared with measured data. The interior noise analysis procedure of construction equipment cabins is expected to be used during the preliminary design stage

  5. Electrochemical Random Signal Analysis during Localized Corrosion of Anodized 1100 Aluminum Alloy in Chloride Environments

    International Nuclear Information System (INIS)

    Sakairi, M.; Shimoyama, Y.; Nagasawa, D.

    2008-01-01

    A new type of electrochemical random signal (electrochemical noise) analysis technique was applied to localized corrosion of anodic oxide film formed 1100 aluminum alloy in 0.5 kmol/m 3 H 3 BO 4 /0.05 kmol/m 3 Na 2 B 4 O 7 with 0.01 kmol/m 3 NaCl. The effect of anodic oxide film structure, barrier type, porous type, and composite type on galvanic corrosion resistance was also examined. Before localized corrosion started, incubation period for pitting corrosion, both current and potential slightly change as initial value with time. The incubation period of porous type anodic oxide specimens are longer than that of barrier type anodic oxide specimens. While pitting corrosion, the current and potential were changed with fluctuations and the potential and the current fluctuations show a good correlation. The records of the current and potential were processed by calculating the power spectrum density (PSD) by the Fast Fourier Transform (FFT) method. The potential and current PSD decrease with increasing frequency, and the slopes are steeper than or equal to minus one (-1). This technique allows observation of electrochemical impedance changes during localized corrosion

  6. Detection of localised corrosion by means of statistic and harmonic analysis of spontaneous potential noise

    International Nuclear Information System (INIS)

    Carassiti, F.; Cigna, R.; Goolamallee, R.; Gusmano, G.

    1989-01-01

    The analysis of the electrochemical noise, i.e. of the spontaneous fluctuations of potential of a freely corroding electrode, probably represent one of the most interesting novelty of the last years in the field of corrosion monitoring. Although this technique is still at an early stage, it could lead to interesting developments, especially for identifying localized forms of corrosion. The experiments which have been reported in the literature generally agree that in absence of active corrosion a slight variation of the potential is observed accompanied by non gaussian fluctuations; in presence of the onset of pitting a series of sharp variation is observed followed by relatively slow exponential recovery. In the domain of frequency the slope of the noise frequency curve is less than that noticed in the absence of active corrosion. In the domain of time generally the standard deviation of noise is proportional to the corrosion rate. Moreover it has been noticed that small variation in the experimental condition could cause modification in the shape of the spontaneous potential fluctuation and introduce some confusion in the analysis of data. Digital filtering of disturbs could allow a better reproducibility to be achieved. (author) 4 refs., 9 figs

  7. Electrochemical noise evaluation of anodized aluminum. Comparative study against corrosion behaviour in the atmosphere

    Directory of Open Access Journals (Sweden)

    Betancourt, N.

    2003-12-01

    Full Text Available The present work reports the evaluation of aluminum and anodized aluminum by electrochemical noise, as a part of the PATINA/CYTED project of the working group Nº 5. A visual examination is also made. The samples were exposed at several Ibero-American atmospheres up to 2 years of exposure. Different thickness of anodized aluminum were evaluated. The electrochemical potential noise of the 5 μm unexposed sample (pattern showed a different behaviour to that showed by the other anodized specimens. This could be due to a slower sealed of the samples of higher thickness. The same behaviour was observed on the samples exposed at the rural station El Pardo. According to the visual examination, the samples of bare aluminum and those of anodized 5 μm thickness were the most affected by pitting corrosion in the highly polluted atmospheres. A good correlation between corrosion behaviour determined by visual examination and EN was obtained.

    Como parte de las investigaciones de la Red PATINA el grupo de trabajo Nº 5 dedicó su atención al comportamiento del aluminio desnudo y anodizado con diferentes espesores en diferentes atmósferas de Iberoamérica. En el presente trabajo se presenta una evaluación de patrones de aluminio 99,5 % de pureza desnudo y anodizado con espesores de 15 y 25 μm, mediante ruido electroquímico. Los resultados obtenidos se comparan con el comportamiento determinado en diferentes atmósferas durante un período de 2 años. El ruido de voltaje del patrón de 5 μm de espesor presenta un comportamiento diferente al de los restantes espesores, lo que coincide con una mayor susceptibilidad a la corrosión picadura de este primer anodizado. Se reportan también algunas diferencias en el ruido de corriente. Se concluye que mediante la utilización del ruido electroquímico es posible caracterizar el aluminio con respecto a su sensibilidad a la corrosión picadura en condiciones atmosféricas.

  8. Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

    Science.gov (United States)

    Yu, Xiao-Ying; Liu, Bingwen; Yang, Li; Zhu, Zihua; Marshall, Matthew J.

    2016-03-01

    A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

  9. Sensor response time monitoring using noise analysis

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Thie, J.A.; Upadhyaya, B.R.; Holbert, K.E.

    1988-01-01

    Random noise techniques in nuclear power plants have been developed for system surveillance and for analysis of reactor core dynamics. The noise signals also contain information about sensor dynamics, and this can be extracted using frequency, amplitude and time domain analyses. Even though noise analysis has been used for sensor response time testing in some nuclear power plants, an adequate validation of this method has never been carried out. This paper presents the results of limited work recently performed to examine the validity of the noise analysis for sensor response time testing in nuclear power plants. The conclusion is that noise analysis has the potential for detecting gross changes in sensor response but it cannot be used for reliable measurement of response time until more laboratory and field experience is accumulated. The method is more advantageous for testing pressure sensors than it is for temperature sensors. This is because: 1) for temperature sensors, a method called Loop Current Step Response test is available which is quantitatively more exact than noise analysis, 2) no method currently exists for on-line testing of pressure transmitters other than the Power-Interrupt test which is applicable only to force balance pressure transmitters, and 3) pressure sensor response time is affected by sensing line degradation which is inherently taken into account by testing with noise analysis. (author)

  10. Development of Self-Powered Wireless-Ready High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring for Boiler Tubes in Next Generation Coal-based Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xingbo [West Virginia Univ., Morgantown, WV (United States)

    2015-06-30

    The key innovation of this project is the synergy of the high temperature sensor technology based on the science of electrochemical measurement and state-of-the-art wireless communication technology. A novel self-powered wireless high temperature electrochemical sensor system has been developed for coal-fired boilers used for power generation. An initial prototype of the in-situ sensor demonstrated the capability of the wireless communication system in the laboratory and in a pilot plant (Industrial USC Boiler Setting) environment to acquire electrochemical potential and current signals during the corrosion process. Uniform and localized under-coal ash deposit corrosion behavior of Inconel 740 superalloy has been studied at different simulated coal ash hot corrosion environments using the developed sensor. Two typical potential noise patterns were found to correlate with the oxidation and sulfidation stages in the hot coal ash corrosion process. Two characteristic current noise patterns indicate the extent of the corrosion. There was a good correlation between the responses of electrochemical test data and the results from corroded surface analysis. Wireless electrochemical potential and current noise signals from a simulated coal ash hot corrosion process were concurrently transmitted and recorded. The results from the performance evaluation of the sensor confirm a high accuracy in the thermodynamic and kinetic response represented by the electrochemical noise and impedance test data.

  11. Analysis of broadband aerodynamic noise from VS45

    Energy Technology Data Exchange (ETDEWEB)

    Dundabin, P. [Renewable Energy Systems Ltd., Glasgow, Scotland (United Kingdom)

    1997-12-31

    This paper describes the analysis of acoustic data taken from the VS45 at Kaiser-Wilhelm-Koog. The aim was to investigate the dependence of aerodynamic noise on tip speed and angle of attack. In particular, the dependence of noise in individual third octave bands on these variable is examined. The analysis is divided into 3 sections: data selection, data checks and analysis of broadband nacelle noise; analysis of broadband aerodynamic noise and its sensitivity to tip speed and angle of attack. (LN)

  12. Statistical analysis of brake squeal noise

    Science.gov (United States)

    Oberst, S.; Lai, J. C. S.

    2011-06-01

    Despite substantial research efforts applied to the prediction of brake squeal noise since the early 20th century, the mechanisms behind its generation are still not fully understood. Squealing brakes are of significant concern to the automobile industry, mainly because of the costs associated with warranty claims. In order to remedy the problems inherent in designing quieter brakes and, therefore, to understand the mechanisms, a design of experiments study, using a noise dynamometer, was performed by a brake system manufacturer to determine the influence of geometrical parameters (namely, the number and location of slots) of brake pads on brake squeal noise. The experimental results were evaluated with a noise index and ranked for warm and cold brake stops. These data are analysed here using statistical descriptors based on population distributions, and a correlation analysis, to gain greater insight into the functional dependency between the time-averaged friction coefficient as the input and the peak sound pressure level data as the output quantity. The correlation analysis between the time-averaged friction coefficient and peak sound pressure data is performed by applying a semblance analysis and a joint recurrence quantification analysis. Linear measures are compared with complexity measures (nonlinear) based on statistics from the underlying joint recurrence plots. Results show that linear measures cannot be used to rank the noise performance of the four test pad configurations. On the other hand, the ranking of the noise performance of the test pad configurations based on the noise index agrees with that based on nonlinear measures: the higher the nonlinearity between the time-averaged friction coefficient and peak sound pressure, the worse the squeal. These results highlight the nonlinear character of brake squeal and indicate the potential of using nonlinear statistical analysis tools to analyse disc brake squeal.

  13. Corrosion resistance test based on electrochemical noise-limiting the number of long-lasting and costly climate chamber tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Veldman, D.; Gouwen, R.J.; Bende, E.E.; Eerenstein, W.

    2013-10-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. The electrochemical noise (EcN) set-up is a fast, direct corrosion measurement of solar cells, whereby results can be obtained within one hour. EcN measurements are presented for several solar cell concepts and different environments. It correlates with damp-heat degradation involving corrosion, which is rather common in EVA-encapsulated crystalline Si modules. Furthermore, the EcN test can be done as an evaluation tool when probing alternative brands, formulations or processing for metallisation pastes and as a screening test for new batches of metallisation paste.

  14. Reactor sensor surveillance using noise analysis

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Thie, J.A.; Upadhyaya, B.R.

    1986-01-01

    Reactor noise signals, as measured by neutron detectors and process sensors, contain information about the dynamics of the process and sensor characteristics. The extent of sensor characteristics that can be determined from such measurements depends on the sensor type, the property of the process noise exciting the sensor and its location. This paper addresses degradation monitoring of temperature and pressure sensors, analysis methods and results of application to operating pressurized water reactors. In addition, the use of noise analysis for monitoring of pressure sensing lines in nuclear power plants is discussed

  15. Study crevice corrosion alloys C-22 and 625 by electrochemical noise

    International Nuclear Information System (INIS)

    Ungaro, María L.; Carranza, Ricardo M.; Rodríguez, Martín A.

    2013-01-01

    C-22 and 625 alloys are two of the Ni –Cr-Mo alloys considered as candidate materials to form the corrosion resistance engineered barriers for nuclear waste repositories. The corrosion resistance of these alloys is remarkable in a wide variety of environments. Despite of their resistance these alloys are susceptible to crevice corrosion in a certain aggressive environments. This work presents the use of electrochemical noise technique to study crevice corrosion susceptibility of alloys C-22 and 625 in 1M NaCl acidic solutions at 60ºC and 90ºC. Asymmetrical electrodes and a complementary platinum electrode were used to assess the influence of cathodic reaction in crevice process. The obtained records were analyzed directly and through statistical parameters. The potential drop and the simultaneous increment of the current records indicated the occurrence of crevice corrosion. The alternative use of a platinum electrode resulted in higher currents and higher potentials and reduced the induction time to crevice formation. The reason for this behavior is that platinum surface allows faster cathodic reactions than C-22 and 625 alloys. The standard deviation of the current records was responsive to the crevice corrosion intensity. C-22 alloy had better crevice corrosion performance than 625 alloy. (author)

  16. Analysis of electrochemical noise data in both time and frequency domains to evaluate the effect of ZnO nanopowder addition on the corrosion protection performance of epoxy coatings

    Directory of Open Access Journals (Sweden)

    H. Ashassi-Sorkhabi

    2016-11-01

    Full Text Available Epoxy–ZnO nanocomposite coatings have been developed for corrosion protection of steel. Structural characterization of the prepared nanocomposites was performed using scanning electron microscopy (SEM. The anti-corrosive properties of the coatings were evaluated by electrochemical noise (EN. On the basis of the EN results in both time and frequency domains, the nanocomposite material with low ZnO concentration (0.1% wt.% was found to be much superior in corrosion protection when tested in aqueous NaCl electrolyte. Finally, EIS measurements were carried out and the data fitted with suitable equivalent circuit. Resistance parameters obtained by both techniques were found to be in relatively good agreement.

  17. Evaluation of the Microbiologically Influenced Corrosion in a carbon steel making use of electrochemical techniques

    International Nuclear Information System (INIS)

    Diaz S, A.C.; Arganis, C.; Ayala, V.; Gachuz, M.; Merino, J.; Suarez, S.; Brena, M.; Luna, P.

    2001-01-01

    The Microbiologically Influenced Corrosion (MIC) has been identified as a problem of the nuclear plants systems in the last years. The electrochemical behavior of metal coupons of carbon steel submitted to the action of sulfate reducing bacteria (SRB) was evaluated, making use of the electrochemical techniques of direct current as well as electrochemical noise. The generated results show a little variation in the corrosion velocities which obtained by Tafel extrapolation and resistance to the linear polarization, whereas the electrochemical noise technique presented important differences as regards the registered behavior in environment with and without microorganisms. (Author)

  18. Noise resistance applied to the study paints

    International Nuclear Information System (INIS)

    Lanchas Garcia-Zarco, S.; Alfosin Perez, V.; Suarez Garcia, A.; Urrejola Madrinan, S.; Sanchez Bermudez, A.

    2015-01-01

    Electrochemical noise is one of the methods of analysis used to interpret the phenomenon of corrosion. It has a number of advantages over other methodology types including its simplicity, its low cost and the fact that it does not disturb the system. This methodology appears to be effective together with other techniques in metal-electrolyte systems. In this case the technique is applied on its own on commercial anti-corrosion paints for which no information is available from other techniques. The main result of this study reveals the effectiveness of the noise resistance parameter, which had already been tested in the lab, when it is used to explain how the paint system behaves in industry. (Author)

  19. The Analysis of Low Noise Protection Barriers Influence on Tram Traffic Noise Levels

    Directory of Open Access Journals (Sweden)

    Ahac Maja

    2013-07-01

    Full Text Available The paper describes the analysis of tram traffic noise situation in residential areas in the vicinity of Drzic Avenue, one of the major routes between the northern and southern part of the Croatian capital city Zagreb, and the effect of low barriers placed by the tracks on tram noise mitigation. In order to evaluate the effect of planned protection measure, noise models were produced and verified with short-term field measurements. Calculations were conducted by means of noise prediction software, using European interim noise prediction method and 3D model of analyzed area. Finally, the results of noise calculations for existing tram traffic situation and planned measure of protection are presented on noise maps.

  20. Electrochemical Analysis of Neurotransmitters

    Science.gov (United States)

    Bucher, Elizabeth S.; Wightman, R. Mark

    2015-07-01

    Chemical signaling through the release of neurotransmitters into the extracellular space is the primary means of communication between neurons. More than four decades ago, Ralph Adams and his colleagues realized the utility of electrochemical methods for the study of easily oxidizable neurotransmitters, such as dopamine, norepinephrine, and serotonin and their metabolites. Today, electrochemical techniques are frequently coupled to microelectrodes to enable spatially resolved recordings of rapid neurotransmitter dynamics in a variety of biological preparations spanning from single cells to the intact brain of behaving animals. In this review, we provide a basic overview of the principles underlying constant-potential amperometry and fast-scan cyclic voltammetry, the most commonly employed electrochemical techniques, and the general application of these methods to the study of neurotransmission. We thereafter discuss several recent developments in sensor design and experimental methodology that are challenging the current limitations defining the application of electrochemical methods to neurotransmitter measurements.

  1. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  2. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  3. Noise estimation for remote sensing image data analysis

    Science.gov (United States)

    Du, Qian

    2004-01-01

    Noise estimation does not receive much attention in remote sensing society. It may be because normally noise is not large enough to impair image analysis result. Noise estimation is also very challenging due to the randomness nature of the noise (for random noise) and the difficulty of separating the noise component from the signal in each specific location. We review and propose seven different types of methods to estimate noise variance and noise covariance matrix in a remotely sensed image. In the experiment, it is demonstrated that a good noise estimate can improve the performance of an algorithm via noise whitening if this algorithm assumes white noise.

  4. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  5. Noise resistance applied to the study of zinc rich paints; Aplicacion de la resistencia de ruido al estudio de pinturas ricas en zinc

    Energy Technology Data Exchange (ETDEWEB)

    Espada Recarey, L.; Sanchez Bermudez, A.; Urrejola Madrinan, S.; Bouzada Alvela, F. [Universidad de Vigo (Spain)

    2001-07-01

    Electrochemical Noise has been one of the more useful analysis methods to the study the corrosion processes due to the fact that it is simple and cheap. The objective of this work is to check the efficiency of this technique when it is applied to the study of Rich Zinc Paints and specifically the Noise Resistance parameter which is very efficiency to study metal-electrolyte systems. Then this technique was applied to Rich Zinc Paints systems of which we have already information by means of electrochemical impedance spectroscopy. The outcomes of this paper show the efficiency of applying Noise Resistance technique to explain the behavior of this kind of systems. (Author) 18 refs.

  6. Noise elimination algorithm for modal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bao, X. X., E-mail: baoxingxian@upc.edu.cn [Department of Naval Architecture and Ocean Engineering, China University of Petroleum (East China), Qingdao 266580 (China); Li, C. L. [Key Laboratory of Marine Geology and Environment, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071 (China); Xiong, C. B. [The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061 (China)

    2015-07-27

    Modal analysis is an ongoing interdisciplinary physical issue. Modal parameters estimation is applied to determine the dynamic characteristics of structures under vibration excitation. Modal analysis is more challenging for the measured vibration response signals are contaminated with noise. This study develops a mathematical algorithm of structured low rank approximation combined with the complex exponential method to estimate the modal parameters. Physical experiments using a steel cantilever beam with ten accelerometers mounted, excited by an impulse load, demonstrate that this method can significantly eliminate noise from measured signals and accurately identify the modal frequencies and damping ratios. This study provides a fundamental mechanism of noise elimination using structured low rank approximation in physical fields.

  7. Reactor surveillance by noise analysis

    International Nuclear Information System (INIS)

    Ciftcioglu, Ozer

    1988-01-01

    A real-time noise analysis system is designed for the TRIGA reactor at Istanbul Technical University. By means of the noise techniques, reactor surveillance is performed together with failure diagnosis. The fast data processing is carried out by FFT in real-time so that malfunction or non-stationary operation of the reactor in long term can be identified by comparing the noise power spectra with the corresponding reference patterns while the decision making procedure is accomplished by the method of hypothesis testing. The system being computer based safety instrumentation involves CAMAC in conjunction with the RT-11 (PDP-11) single user dedicated environment. (author)

  8. Deaf Smith County noise analysis: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    An analysis of activities proposed for the three major phases of development of the proposed nuclear waste repository site in Deaf Smith County, Texas, was conducted to quantify the noise levels and the effect of noise resulting from these activities. The report provides additional details of the predictive noise level modeling conducted for the site characterization, repository construction, and repository operation phases. Equivalent day/night sound levels are presented for each phase as sound level contours. Sound levels from onsite and offsite activities are addressed including traffic on access routes, and railroad construction and operation. A description of the predictive models, the analysis methodologies, the noise source inventories, the model outputs, and the evaluation criteria are included. 35 refs., 6 figs., 2 tabs

  9. Integrating neural network technology and noise analysis

    International Nuclear Information System (INIS)

    Uhrig, R.E.; Oak Ridge National Lab., TN

    1995-01-01

    The integrated use of neural network and noise analysis technologies offers advantages not available by the use of either technology alone. The application of neural network technology to noise analysis offers an opportunity to expand the scope of problems where noise analysis is useful and unique ways in which the integration of these technologies can be used productively. The two-sensor technique, in which the responses of two sensors to an unknown driving source are related, is used to demonstration such integration. The relationship between power spectral densities (PSDs) of accelerometer signals is derived theoretically using noise analysis to demonstrate its uniqueness. This relationship is modeled from experimental data using a neural network when the system is working properly, and the actual PSD of one sensor is compared with the PSD of that sensor predicted by the neural network using the PSD of the other sensor as an input. A significant deviation between the actual and predicted PSDs indicate that system is changing (i.e., failing). Experiments carried out on check values and bearings illustrate the usefulness of the methodology developed. (Author)

  10. Analysis of a Shock-Associated Noise Prediction Model Using Measured Jet Far-Field Noise Data

    Science.gov (United States)

    Dahl, Milo D.; Sharpe, Jacob A.

    2014-01-01

    A code for predicting supersonic jet broadband shock-associated noise was assessed using a database containing noise measurements of a jet issuing from a convergent nozzle. The jet was operated at 24 conditions covering six fully expanded Mach numbers with four total temperature ratios. To enable comparisons of the predicted shock-associated noise component spectra with data, the measured total jet noise spectra were separated into mixing noise and shock-associated noise component spectra. Comparisons between predicted and measured shock-associated noise component spectra were used to identify deficiencies in the prediction model. Proposed revisions to the model, based on a study of the overall sound pressure levels for the shock-associated noise component of the measured data, a sensitivity analysis of the model parameters with emphasis on the definition of the convection velocity parameter, and a least-squares fit of the predicted to the measured shock-associated noise component spectra, resulted in a new definition for the source strength spectrum in the model. An error analysis showed that the average error in the predicted spectra was reduced by as much as 3.5 dB for the revised model relative to the average error for the original model.

  11. Surveillance of instruments by noise analysis

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Random fluctuations of neutron flux, temperature, and pressure in a reactor provide multifrequency excitation of the corresponding instrumentation chains. Mathematical descriptors suitable for characterizing the output, or noise, of the instrumentation are reviewed with a view toward using such noise in detecting instrument faults. Demonstrations of the feasibility of this approach in a number of reactors provide illustrative examples. Comparisons with traditional surveillance testing are made, and a number of advantages and some disadvantages of using noise analysis as a supplementary technique are pointed out

  12. Environmental analysis by electrochemical sensors and biosensors fundamentals

    CERN Document Server

    Moretto, Ligia Maria

    2014-01-01

    This book presents an exhaustive overview of electrochemical sensors and biosensors for the analysis and monitoring of the most important analytes in the environmental field, in industry, in treatment plants and in environmental research. The chapters give the reader a comprehensive, state-of-the-art picture of the field of electrochemical sensors suitable to environmental analytes, from the theoretical principles of their design to their implementation, realization and application. The first three chapters discuss fundamentals, and the last three chapters cover the main groups of analytes of environmental interest.

  13. Modeling of pH Dependent Electrochemical Noise in Ion Sensitive Field Effect Transistors ISFET

    OpenAIRE

    M. P. Das; M. Bhuyan

    2013-01-01

    pH ISFETs are very important sensor for in vivo continuous monitoring application of physiological and environmental system. The accuracy of Ion Sensitive Field Effect Transistor (ISFET) output measurement is greatly affected by the presences of noise, drift and slow response of the device. Although the noise analysis of ISFET so far performed in different literature relates only to sources originated from Field Effect Transistor (FET) structure which are almost constant for a particular devi...

  14. Electrochemical capacity fading of polyaniline electrode in supercapacitor: An XPS analysis

    Directory of Open Access Journals (Sweden)

    Jinxing Deng

    2017-04-01

    Full Text Available To understand the electrochemical capacity fading of the polyaniline (PANI electrodes in supercapacitors, for the first time, their chemical structure change during electrochemical cycles was traced with XPS analysis after the HCl doped PANI electrodes were subjected to the cyclic voltammetry test in 1.0 M H2SO4 electrolyte for different cycle numbers. The results showed that the chlorine disappeared in the electrode surface, while the surface element contents of sulfur and oxygen increased with the electrochemical cycles increased. It demonstrated that the hydrolytic degradation of the PANI chains and exchange of dopant occurred during the electrochemical cycling, causing the fading in the mechanical and electrochemical performance of the PANI electrodes. This understanding should lead to better design of the conductive polymer-based energy storage devices.

  15. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  16. Correlation of Process Data and Electrochemical Noise to Assess Kraft Digester Corrosion: Kamloops Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, SJ

    2002-05-09

    Electrochemical noise (ECN) probes were deployed in a carbon steel continuous kraft digester at five locations roughly equi-spaced from top to bottom of the vessel. Current and potential noise, the temperature at each probe location, and the value of about 60 process parameters (flow rates, liquor chemistry, etc.) were monitored continuously for a period of one year. Historical vessel inspection data, including inspections accomplished immediately prior to and immediately following probe deployment, and post-test evaluation of the probe components were used to assess/compare corrosion indications from the probes with physical changes in wall thickness and corrosion patterns on the digester shell. The results indicate that furnish composition is a significant variable influencing digester corrosion, with increasing amounts of Douglas fir in the nominal furnish correlating directly with increased corrosion activity on the ECN probes. All five probes detected changes in furnish composition approximately simultaneously, indicating rapid chemical communication through the liquor, but the effect was strongest and persisted longest relatively high in the digester. The ECN probes also indicate significant corrosion activity occurred at each probe position during shutdown/restart transients. Little or no correlation between ECN probe corrosion activity and other operational variables was observed. Post-test evaluation of the probes confirmed general corrosion of a magnitude that closely agreed with corrosion current sums calculated for each probe over the exposure period and with historical average corrosion rates for the respective locations. Further, no pitting was observed on any of the electrodes, which is consistent with the ECN data, relevant polarization curves developed for steel in liquor removed from the digester, and the post-test inspection of the digester.

  17. On-line analysis of reactor noise using time-series analysis

    International Nuclear Information System (INIS)

    McGevna, V.G.

    1981-10-01

    A method to allow use of time series analysis for on-line noise analysis has been developed. On-line analysis of noise in nuclear power reactors has been limited primarily to spectral analysis and related frequency domain techniques. Time series analysis has many distinct advantages over spectral analysis in the automated processing of reactor noise. However, fitting an autoregressive-moving average (ARMA) model to time series data involves non-linear least squares estimation. Unless a high speed, general purpose computer is available, the calculations become too time consuming for on-line applications. To eliminate this problem, a special purpose algorithm was developed for fitting ARMA models. While it is based on a combination of steepest descent and Taylor series linearization, properties of the ARMA model are used so that the auto- and cross-correlation functions can be used to eliminate the need for estimating derivatives. The number of calculations, per iteration varies lineegardless of the mee 0.2% yield strength displayed anisotropy, with axial and circumferential values being greater than radial. For CF8-CPF8 and CF8M-CPF8M castings to meet current ASME Code S acid fuel cells

  18. Receive-Noise Analysis of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Bozkurt, Ayhan; Yaralioglu, G Goksenin

    2016-11-01

    This paper presents an analysis of thermal (Johnson) noise received from the radiation medium by otherwise noiseless capacitive micromachined ultrasonic transducer (CMUT) membranes operating in their fundamental resonance mode. Determination of thermal noise received by multiple numbers of transducers or a transducer array requires the assessment of cross-coupling through the radiation medium, as well as the self-radiation impedance of the individual transducer. We show that the total thermal noise received by the cells of a CMUT has insignificant correlation, and is independent of the radiation impedance, but is only determined by the mass of each membrane and the electromechanical transformer ratio. The proof is based on the analytical derivations for a simple transducer with two cells, and extended to transducers with numerous cells using circuit simulators. We used a first-order model, which incorporates the fundamental resonance of the CMUT. Noise power is calculated by integrating over the entire spectrum; hence, the presented figures are an upper bound for the noise. The presented analyses are valid for a transimpedance amplifier in the receive path. We use the analysis results to calculate the minimum detectable pressure of a CMUT. We also provide an analysis based on the experimental data to show that output noise power is limited by and comparable to the theoretical upper limit.

  19. Dynamical analysis of electrochemical wall shear rate measurements

    NARCIS (Netherlands)

    Steenhoven, van A.A.; Beucken, van den F.J.H.M.

    1991-01-01

    The performance of a circular electrochemical wall shear rate probe under unsteady flow conditions is analysed through a combined ezxperimental, numerical and analytical approach. The experiments are performed with a ferri- and ferrocyanide redox couple and compared to finite element analysis of the

  20. Neutron noise analysis for malfunction diagnosis at sodium cooled reactors

    International Nuclear Information System (INIS)

    Hoppe, P.

    1978-09-01

    For the investigation of the potential use of neutron noise analysis at sodium cooled power reactors, measurements have been performed at the KNK I reactor over a period of 18 month under different operational conditions. The signal fluctuations of the following tranducers have been recorded: In-core and Ex-core neutron detectors, temperature-, flow-, pressure-, vibration- and acoustic sensors. These extensive measurements have been analyzed in the frequency range from 0,001 Hz to 1000 Hz with all currently known methods for the identification of noise sources. The following results have been found: - Neutron noise for f 20 Hz the white detection noise prevails. In the region from 1 Hz to 20 Hz the vibrations of core components contribute to neutron noise. - Neutron noise is influenced by the state of the plant. - The contributions to neutron noise due to the fluctuations of coolant flow and inlet temperature are small compared to those produced by the movements of the control rod initiated by the reactor control system. The quantitatively unidentifiable amount of reactivity fluctuations (0,6 time-dependent thermal bowing of the core. With respect to these results and by calculation of the neutron noise patterns to be expected for the SNR 300, the following possible applications for neutron noise analysis have been found: By means of neutron noise analysis only reactivity fluctuations can be identified and supervised which are produced by time dependent changes of the core geometry. Furthermore neutron noise analysis is well suited for a sensitive detection of control rod vibrations and of local sodium boiling. Finally it can be used for the surveillance of the proper functioning of the reactor control system and of the control rod drive mechanism. (orig./HP) 891 HP [de

  1. Analysis of Subway Interior Noise at Peak Commuter Time.

    Science.gov (United States)

    Lee, Donguk; Kim, Gibbeum; Han, Woojae

    2017-07-01

    Although mass transit systems are convenient and efficient for urban people, little attention has been paid to the potential hearing hazard from their noise. The purpose of the current study was to measure and analyze levels of subway interior noise at peak commuter times and to provide information about commuters' daily dose of noise exposure. To measure the subway interior noise, nine subway lines inside Seoul (i.e., lines 1-9) and six lines surrounding the capital city area (i.e., Central, Bundang, Sinbundang, Incheon, Gyeongui, and Gyeongchun) were chosen. The noise was measured and recorded by a sound level meter for two-hour periods in the morning and evening. 1) In the LZeq analysis, the average noise level of all 15 lines was 72.78 dB; the maximum and minimum noise levels were 78.34 and 62.46 dB, respectively. The average noise level of the nine lines inside Seoul was 73.45 dB, which was 1.68-dB louder than that of the six lines surrounding the capital city area. 2) Based on the LZeq analysis of 33 measured frequencies, 12.5 Hz was the highest frequency and 20,000 Hz was the lowest. 3) There was no remarkable difference in the level of subway interior noise between morning and evening peak commuter times. We concluded that the level of subway interior noise was not loud enough for commuters to incur noise-induced hearing loss. Regardless, environmental noise control efforts in the subway system might be needed for commuters who take a subway every day.

  2. Research on neutron noise analysis stochastic simulation method for α calculation

    International Nuclear Information System (INIS)

    Zhong Bin; Shen Huayun; She Ruogu; Zhu Shengdong; Xiao Gang

    2014-01-01

    The prompt decay constant α has significant application on the physical design and safety analysis in nuclear facilities. To overcome the difficulty of a value calculation with Monte-Carlo method, and improve the precision, a new method based on the neutron noise analysis technology was presented. This method employs the stochastic simulation and the theory of neutron noise analysis technology. Firstly, the evolution of stochastic neutron was simulated by discrete-events Monte-Carlo method based on the theory of generalized Semi-Markov process, then the neutron noise in detectors was solved from neutron signal. Secondly, the neutron noise analysis methods such as Rossia method, Feynman-α method, zero-probability method, and cross-correlation method were used to calculate a value. All of the parameters used in neutron noise analysis method were calculated based on auto-adaptive arithmetic. The a value from these methods accords with each other, the largest relative deviation is 7.9%, which proves the feasibility of a calculation method based on neutron noise analysis stochastic simulation. (authors)

  3. Noise Analysis of MAIA System and Possible Noise Suppression

    Czech Academy of Sciences Publication Activity Database

    Švihlík, J.; Fliegel, K.; Koten, Pavel; Vítek, S.; Páta, P.

    2011-01-01

    Roč. 20, č. 1 (2011), s. 110-117 ISSN 1210-2512. [International Conference on Telecommunications and Signal Processing /33./ - TSP 2010. Baden near Vienna, 17.08.2010-20.08.2010] Institutional research plan: CEZ:AV0Z10030501 Keywords : MAIA * meteor * noise analysis Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 0.739, year: 2011

  4. Measurement and analysis of self-noise in hybrid-driven underwater gliders

    Directory of Open Access Journals (Sweden)

    LIU Lu

    2017-08-01

    Full Text Available The Hybrid-driven Underwater Glider (HUG is a new type of submersible vehicle which combines the functions of traditional Autonomous Underwater Vehicles(AUVand Autonomous Underwater Gliders(AUG. In order to study its noise source distribution and basic self-noise characteristics, a self-noise acquisition system based on the HUG was designed and developed, and a noise analysis test carried out in a free-field pool. In August 2016, the sea trial of the Petrel II glider was conducted in the South China Sea, with observation data at a depth range of 1 000 m as the research object. The self-noise data of the glider platform under different working conditions was obtained through the step-by-step operation method. The experimental analysis and results show that the self-noise acquisition system is stable. The contribution of mechanical noise to self-noise is greatest when the glider works in the gliding mode, while the self-noise band above 500 Hz is closely related to the work of the buoyancy adjustment unit, and peaks at 1 kHz. According to the analysis of the basic characteristics of self-noise, this provides some guidance for the implementation of vibration and noise reduction.

  5. Electrochemical techniques for practical evaluation of corrosion inhibitor effectiveness. Performance of cerium nitrate as corrosion inhibitor for AA2024T3 alloy

    International Nuclear Information System (INIS)

    Rosero-Navarro, N.C.; Curioni, M.; Bingham, R.; Duran, A.; Aparicio, M.; Cottis, R.A.; Thompson, G.E.

    2010-01-01

    In this work, a split-cell technique and image-assisted electrochemical noise analysis, which provide minimal perturbation of the freely corroding system and good time resolution, are proposed as a tool for simultaneous investigation of the corrosion inhibition mechanism and assessment of performance. The results obtained are compared with results from traditional electrochemical impedance spectroscopy, disclosing the advantages of these techniques in the evaluation of inhibitor performance. Specific attention is also given to the investigation of corrosion inhibition by cerium nitrate.

  6. Analysis of reactor noise; Analiza reaktorskih sumova

    Energy Technology Data Exchange (ETDEWEB)

    Velickovic, Lj [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1967-11-15

    This paper describes the theoretical model for interpretation of experimental results, experimental method for study of reactor noise at the RB reactor, numerical treatment of experimental results by correlation technique for analysis of reactor noise. A computer code was written to obtain autocorrelation function and spectral density function. Experimental results obtained by oscillator technique, pulse technique, and autocorrelation method are presented and discussed.

  7. Thin film microelectrodes for electrochemical detection of neurotransmitters

    DEFF Research Database (Denmark)

    Larsen, Simon Tylsgaard

    An important signaling process in the nervous system is the release of chemical messengers called neurotransmitters from neurons. In this thesis alternative thin film electrode materials for applications targeting electrochemical detection of neurotransmitters in chip devices were evaluated...... and conductive polymer microelectrodes made of Pedot:Pss were also fabricated and used successfully to measure transmitter release from cells. The use of different thin film electrodes for low-noise amperometric measurements of single events of transmitter release from neuronal cells was studied....... For this application a very low current noise is needed together with a large temporal resolution. It was shown, that resistive and capacitive properties of thin film electrode materials are determining their usefulness in low-noise amperometric measurements. An analytical expression for the noise was derived...

  8. Noise analysis for CCD-based ultraviolet and visible spectrophotometry.

    Science.gov (United States)

    Davenport, John J; Hodgkinson, Jane; Saffell, John R; Tatam, Ralph P

    2015-09-20

    We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4)  AU for the AvaSpec-3648 and 5.6×10(-4)  AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.

  9. Analysis of noise lines in the Virgo C7 data

    International Nuclear Information System (INIS)

    Acernese, F; Amico, P; Alshourbagy, M

    2007-01-01

    The paper presents a description of the work of detection and identification of frequency lines in the Virgo dark fringe data from run C7. A number of methods are highlighted by which noise frequency lines are detected by data analysis and measurements in the laboratory. In this paper we give a description of the list of noise line candidates provided by the pulsar search analysis, the investigation of 10 Hz (and harmonics) noise, violin modes, noise from the end station buildings' air conditioners, sidebands in calibration lines and aliasing in the 4 kHz reconstructed data

  10. Analysis of noise lines in the Virgo C7 data

    Energy Technology Data Exchange (ETDEWEB)

    Acernese, F [INFN, Sezione di Napoli and/or Universita di Napoli ' Federico II' Complesso Universitario di Monte S Angelo, and/or Universita di Salerno, Fisciano (Italy); Amico, P [INFN, Sezione di Perugia and/or Universita di Perugia, Perugia (Italy); Alshourbagy, M [INFN, Sezione di Pisa and/or Universita di Pisa, Pisa (Italy)] (and others)

    2007-10-07

    The paper presents a description of the work of detection and identification of frequency lines in the Virgo dark fringe data from run C7. A number of methods are highlighted by which noise frequency lines are detected by data analysis and measurements in the laboratory. In this paper we give a description of the list of noise line candidates provided by the pulsar search analysis, the investigation of 10 Hz (and harmonics) noise, violin modes, noise from the end station buildings' air conditioners, sidebands in calibration lines and aliasing in the 4 kHz reconstructed data.

  11. Electrochemical study of stress corrosion cracking of copper alloys

    International Nuclear Information System (INIS)

    Malki, Brahim

    1999-01-01

    This work deals with the electrochemical study of stress corrosion of copper alloys in aqueous environment. Selective dissolution and electrochemical oxidation are two key-points of the stress corrosion of these alloys. The first part of this thesis treats of these aspects applied to Cu-Au alloys. Measurements have been performed using classical electrochemical techniques (in potentio-dynamic, potentio-static and galvano-static modes). The conditions of occurrence of an electrochemical noise is analysed using signal processing techniques. The impact on the behavior of Cu 3 Au are discussed. In the second part, the stress corrosion problem is addressed in the case of surface oxide film formation, in particular for Cu-Zn alloys. We have found useful to extend this study to mechanical stress oxidation mechanisms in the presence of an oscillating potential electrochemical system. The aim is to examine the influence of these new electrochemical conditions (galvano-static mode) on the behavior of stressed brass. Finally, the potential distribution at crack tip is calculated in order to compare the different observations [fr

  12. Applications of aero-acoustic analysis to wind turbine noise control

    International Nuclear Information System (INIS)

    Lowson, M.V.

    1992-01-01

    Wind turbine noise generation mechanisms are essentially equivalent to the aero-acoustic mechanisms of other rotors, which have been studied in depth for many years. Basic sources for the wind turbine noise radiation process are defined, and their significance assessed. From the analysis, areas of potential improvement in wind turbine noise prediction are defined. Suggestions are made for approaches to wind turbine noise control which separate the noise problems at cut-in from those at rated power. Some of these offer the possibility of noise reduction without unfavourable effects on performance. (author)

  13. Applications of aero-acoustic analysis to wind turbine noise control

    International Nuclear Information System (INIS)

    Lowson, M.

    1993-01-01

    Wind turbine noise generation mechanisms are essentially equivalent to the aero-acoustic mechanisms of other rotors, which have been studied in depth for many years. Basic sources for the wind turbine noise radiation process are defined, and their significance assessed. From the analysis, areas of potential improvement in wind turbine noise prediction are defined. Suggestions are made for approaches to wind turbine noise control which separate the noise problems at cut-in from those at rated power. Some of these offer the possibility of noise reduction without unfavourable effects on performance. (author)

  14. Recent progress in safety-related applications of reactor noise analysis

    International Nuclear Information System (INIS)

    Hirota, Jitsuya; Shinohara, Yoshikuni; Saito, Keiichi

    1982-01-01

    Recent progress in safety-related applications of reactor noise analysis is reviewed, mainly referring to various papers presented at the Third Specialists' Meeting on Reactor Noise (SMORN-III) held in Tokyo in 1981. Advances in application of autoregressive model, coherence analysis and pattern recognition technique are significant since SMORN-II in 1977. Development of reactor diagnosis systems based on noise analysis is in progress. Practical experiences in the safety-related applications to power plants are being accumulated. Advances in quantitative monitoring of vibration of internal structures in PWR and diagnosis of core stability and control system characteristics in BWR are notable. Acoustic methods are also improved to detect sodium boiling in LMFBR. The Reactor Noise Analysis Benchmark Test performed by Japan in connection with SMORN-III is successful so that it is possible to proceed to the second stage of the benchmark test. (author)

  15. Reactor noise analysis applications in NPP I and C systems

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, O. [International Atomic Energy Agency, Wagramer Strosse 5, A-1400 Vienna, Austria Ontario Power Generation, 230 Westney Road South, Ajax, Ont. L1S 7R3 (Canada)

    2006-07-01

    Reactor noise analysis techniques are used in many NPPs on a routine basis as 'inspection tools' to get information on the dynamics of reactor processes and their instrumentation in a passive, non-intrusive way. The paper discusses some of the tasks and requirements an NPP has to take to implement and to use the full advantages of reactor noise analysis techniques. Typical signal noise analysis applications developed for the monitoring of the reactor shutdown system and control system instrumentation of the Candu units of Ontario Power Generation and Bruce Power are also presented. (authors)

  16. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    OpenAIRE

    Anastasios Economou

    2018-01-01

    This work reviews the field of screen-printed electrodes (SPEs) modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have ...

  17. Nanoelectrode array for electrochemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yelton, William G [Sandia Park, NM; Siegal, Michael P [Albuquerque, NM

    2009-12-01

    A nanoelectrode array comprises a plurality of nanoelectrodes wherein the geometric dimensions of the electrode controls the electrochemical response, and the current density is independent of time. By combining a massive array of nanoelectrodes in parallel, the current signal can be amplified while still retaining the beneficial geometric advantages of nanoelectrodes. Such nanoelectrode arrays can be used in a sensor system for rapid, non-contaminating field analysis. For example, an array of suitably functionalized nanoelectrodes can be incorporated into a small, integrated sensor system that can identify many species rapidly and simultaneously under field conditions in high-resistivity water, without the need for chemical addition to increase conductivity.

  18. Temporal Noise Analysis of Charge-Domain Sampling Readout Circuits for CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Xiaoliang Ge

    2018-02-01

    Full Text Available This paper presents a temporal noise analysis of charge-domain sampling readout circuits for Complementary Metal-Oxide Semiconductor (CMOS image sensors. In order to address the trade-off between the low input-referred noise and high dynamic range, a Gm-cell-based pixel together with a charge-domain correlated-double sampling (CDS technique has been proposed to provide a way to efficiently embed a tunable conversion gain along the read-out path. Such readout topology, however, operates in a non-stationery large-signal behavior, and the statistical properties of its temporal noise are a function of time. Conventional noise analysis methods for CMOS image sensors are based on steady-state signal models, and therefore cannot be readily applied for Gm-cell-based pixels. In this paper, we develop analysis models for both thermal noise and flicker noise in Gm-cell-based pixels by employing the time-domain linear analysis approach and the non-stationary noise analysis theory, which help to quantitatively evaluate the temporal noise characteristic of Gm-cell-based pixels. Both models were numerically computed in MATLAB using design parameters of a prototype chip, and compared with both simulation and experimental results. The good agreement between the theoretical and measurement results verifies the effectiveness of the proposed noise analysis models.

  19. To the analysis of reactor noise in boiling water reactors

    International Nuclear Information System (INIS)

    Seifritz, W.

    1972-01-01

    The paper contains some basic thoughts on the problem of neutron flux oscillations in power reactors. The advantages of self-powered detectors and their function are explained. In addition, noise measurements of the boiling water reactors at Lingen and Holden are described, and the possibilities of an employment of vanadium detectors for the analysis of reactor noise are discussed. The final pages of the paper contain a complete list of the author's publications in the field of reactor noise analysis. (RW/AK) [de

  20. Quantitative analysis of LISA pathfinder test-mass noise

    International Nuclear Information System (INIS)

    Ferraioli, Luigi; Congedo, Giuseppe; Hueller, Mauro; Vitale, Stefano; Hewitson, Martin; Nofrarias, Miquel; Armano, Michele

    2011-01-01

    LISA Pathfinder (LPF) is a mission aiming to test the critical technology for the forthcoming space-based gravitational-wave detectors. The main scientific objective of the LPF mission is to demonstrate test masses free falling with residual accelerations below 3x10 -14 m s -2 /√(Hz) at 1 mHz. Reaching such an ambitious target will require a significant amount of system optimization and characterization, which will in turn require accurate and quantitative noise analysis procedures. In this paper, we discuss two main problems associated with the analysis of the data from LPF: i) excess noise detection and ii) noise parameter identification. The mission is focused on the low-frequency region ([0.1, 10] mHz) of the available signal spectrum. In such a region, the signal is dominated by the force noise acting on test masses. At the same time, the mission duration is limited to 90 days and typical data segments will be 24 hours in length. Considering those constraints, noise analysis is expected to deal with a limited amount of non-Gaussian data, since the spectrum statistics will be far from Gaussian and the lowest available frequency is limited by the data length. In this paper, we analyze the details of the expected statistics for spectral data and develop two suitable excess noise estimators. One is based on the statistical properties of the integrated spectrum, the other is based on the Kolmogorov-Smirnov test. The sensitivity of the estimators is discussed theoretically for independent data, then the algorithms are tested on LPF synthetic data. The test on realistic LPF data allows the effect of spectral data correlations on the efficiency of the different noise excess estimators to be highlighted. It also reveals the versatility of the Kolmogorov-Smirnov approach, which can be adapted to provide reasonable results on correlated data from a modified version of the standard equations for the inversion of the test statistic. Closely related to excess noise

  1. Note: A temperature-stable low-noise transimpedance amplifier for microcurrent measurement

    Science.gov (United States)

    Xie, Kai; Shi, Xueyou; Zhao, Kai; Guo, Lixin; Zhang, Hanlu

    2017-02-01

    Temperature stability and noise characteristics often run contradictory in microcurrent (e.g., pA-scale) measurement instruments because low-noise performance requires high-value resistors with relatively poor temperature coefficients. A low-noise transimpedance amplifier with high-temperature stability, which involves an active compensation mechanism to overcome the temperature drift mainly caused by high-value resistors, is presented. The implementation uses a specially designed R-2R compensating network to provide programmable current gain with extra-fine trimming resolution. The temperature drifts of all components (e.g., feedback resistors, operational amplifiers, and the R-2R network itself) are compensated simultaneously. Therefore, both low-temperature drift and ultra-low-noise performance can be achieved. With a current gain of 1011 V/A, the internal current noise density was about 0.4 fA/√Hz, and the average temperature coefficient was 4.3 ppm/K at 0-50 °C. The amplifier module maintains accuracy across a wide temperature range without additional thermal stabilization, and its compact size makes it especially suitable for high-precision, low-current measurement in outdoor environments for applications such as electrochemical emission supervision, air pollution particles analysis, radiation monitoring, and bioelectricity.

  2. RB reactor noise analysis; Analiza sumova reaktora RB

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, M; Velickovic, Lj; Markovic, V; Jovanovic, S [Institut za nuklearne nauke Boris Kidric, Vinca, Beograd (Yugoslavia)

    1964-07-01

    Statistical fluctuations of reactivity represent reactor noise. Analysis of reactor noise enables determining a series of reactor kinetic parameters. Fluctuations of power was measured by ionization chamber placed next to the tank of the RB reactor. The signal was digitized by an analog-digital converter. After calculation of the mean power, 3000 data obtained by sampling were analysed.

  3. Multi-scale analysis of teleconnection indices: climate noise and nonlinear trend analysis

    Directory of Open Access Journals (Sweden)

    C. Franzke

    2009-02-01

    Full Text Available The multi-scale nature and climate noise properties of teleconnection indices are examined by using the Empirical Mode Decomposition (EMD procedure. The EMD procedure allows for the analysis of non-stationary time series to extract physically meaningful intrinsic mode functions (IMF and nonlinear trends. The climatologically relevant monthly mean teleconnection indices of the North Atlantic Oscillation (NAO, the North Pacific index (NP and the Southern Annular Mode (SAM are analyzed.

    The significance of IMFs and trends are tested against the null hypothesis of climate noise. The analysis of surrogate monthly mean time series from a red noise process shows that the EMD procedure is effectively a dyadic filter bank and the IMFs (except the first IMF are nearly Gaussian distributed. The distribution of the variance contained in IMFs of an ensemble of AR(1 simulations is nearly χ2 distributed. To test the statistical significance of the IMFs of the teleconnection indices and their nonlinear trends we utilize an ensemble of corresponding monthly averaged AR(1 processes, which we refer to as climate noise. Our results indicate that most of the interannual and decadal variability of the analysed teleconnection indices cannot be distinguished from climate noise. The NP and SAM indices have significant nonlinear trends, while the NAO has no significant trend when tested against a climate noise hypothesis.

  4. The influence of the cathodic process on the interpretation of electrochemical noise signals arising from pitting corrosion of stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, Helmuth Sarmiento [Federal Institute for Materials Research and Testing, Unter den Eichen 87, 12205 Berlin (Germany)], E-mail: Helmuth.sarmiento-klapper@bam.de; Goellner, Joachim [Otto von Guericke University Magdeburg, P.O. Box 4120, Magdeburg (Germany); Heyn, Andreas [Federal Institute for Materials Research and Testing, Unter den Eichen 87, 12205 Berlin (Germany); Otto von Guericke University Magdeburg, P.O. Box 4120, Magdeburg (Germany)

    2010-04-15

    The use of electrochemical noise (EN) measurements for the investigation and monitoring of corrosion has allowed many interesting advances in the corrosion science in recent years. A special advantage of EN measurements includes the possibility to detect and study the early stages of localized corrosion. Nevertheless, the understanding of the electrochemical information included in the EN signal is actually very limited. The role of the cathodic process on the EN signals remains uncertain and has not been sufficiently investigated to date. Thus, an accurate understanding of the influence of the cathodic process on the EN signal is still lacking. On the basis of different kinetics of the oxygen reduction it was established that the anodic amplitude of transients arising from pitting corrosion on stainless steel can be decreased by the corresponding electron consumption of the cathodic process. Therefore, the stronger the electron consumption, the weaker the anodic amplitude of the EN signal becomes. EN signals arising from pitting corrosion on stainless steel can be measured because the cathodic process is inhibited by the passive layer. This was confirmed by means of EN measurements under cathodic polarisation. Since the cathodic process plays a decisive role on the form of transients arising from pitting corrosion, its influence must be considered in the evaluation and interpretation of the EN signals.

  5. Electrochemical analysis in a liposome suspension using lapachol as a hydrophobic electro active species.

    Science.gov (United States)

    Okumura, Noriko; Wakamatsu, Shiori; Uno, Bunji

    2014-01-01

    This study demonstrated that the electro-chemical analysis of hydrophobic quinones can be performed in liposome suspension systems. We prepared and analyzed liposome suspensions containing lapachol, which is a quinone-based anti-tumor activity compound. In this suspension system, a simple one redox couple of lapachol is observed. These results are quite different from those obtained in organic solvents. In addition, the pH dependence of redox behaviors of lapachol could be observed in multilamellar vesicle (MLV) suspension system. This MLV suspension system method may approximate the electrochemical behavior of hydrophobic compounds in aqueous conditions. A benefit of this liposome suspension system for electrochemical analysis is that it enables to observe water-insoluble compounds without using organic solvents.

  6. Intrinsic periodic and aperiodic stochastic resonance in an electrochemical cell

    Science.gov (United States)

    Tiwari, Ishant; Phogat, Richa; Parmananda, P.; Ocampo-Espindola, J. L.; Rivera, M.

    2016-08-01

    In this paper we show the interaction of a composite of a periodic or aperiodic signal and intrinsic electrochemical noise with the nonlinear dynamics of an electrochemical cell configured to study the corrosion of iron in an acidic media. The anodic voltage setpoint (V0) in the cell is chosen such that the anodic current (I ) exhibits excitable fixed point behavior in the absence of noise. The subthreshold periodic (aperiodic) signal consists of a train of rectangular pulses with a fixed amplitude and width, separated by regular (irregular) time intervals. The irregular time intervals chosen are of deterministic and stochastic origins. The amplitude of the intrinsic internal noise, regulated by the concentration of chloride ions, is then monotonically increased, and the provoked dynamics are analyzed. The signal to noise ratio and the cross-correlation coefficient versus the chloride ions' concentration curves have a unimodal shape indicating the emergence of an intrinsic periodic or aperiodic stochastic resonance. The abscissa for the maxima of these unimodal curves correspond to the optimum value of intrinsic noise where maximum regularity of the invoked dynamics is observed. In the particular case of the intrinsic periodic stochastic resonance, the scanning electron microscope images for the electrode metal surfaces are shown for certain values of chloride ions' concentrations. These images, qualitatively, corroborate the emergence of order as a result of the interaction between the nonlinear dynamics and the composite signal.

  7. Development and applications of reactor noise analysis at Ontario Hydro's CANDU reactors

    International Nuclear Information System (INIS)

    Gloeckler, O.; Tulett, M.V.

    1995-01-01

    In 1992 a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro's CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. The dynamic characteristics of critical plant components, instrumentation and processes are monitored on a regular basis. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes induced by moderator flow, (6) estimating the dynamics and response time of RTD (Resistance Temperature Detector) temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (10) detecting coolant boiling in fully instrumented fuel channels, (11) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as-needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology. (author

  8. Electrochemically assisted fast-atom-bombardment mass spectrometry

    International Nuclear Information System (INIS)

    Phillips, L.R.

    1988-01-01

    The hybridization of electrochemistry and fast atom bombardment (FAB) mass spectrometry (MS) creates a new hyphenated technique, referred to as electrochemically assisted FAB (EFAB) MS, which improves the applicability of FAB MS in selectivity and extends the range of compounds to include low polarity molecules, and also reduces mass spectral complications due to matrix-related artifacts. FAB MS has proven to be indispensable in analysis of samples that are otherwise too intractable for conventional MS, such as peptides, oligosaccharides, and oligonucleotides, due to low volatility and ready thermal degradation. There are limits on its applicability, however, in that it works best with samples that are already ionic, or predisposed to become so by simple proton transfer to or from the matrix. A wide range of chemical substances can be ionized/analyzed by electrochemical methods. Therefore, a possible approach towards improving applicability of FAB MS is through its hybridization with electrochemistry. Samples are activated by electrolysis, carried out directly in the sample matrix through use of a modified FAB sample probe which was constructed containing a small electrolytic cell on the tip. In operation, one electrode is held at normal sample-probe/ion-source voltage, while the other electrode can be continuously varied ±15 volts to create electrochemical potentials. Several chemical substances, known to be unresponsive to FAB MS, have been examined by EFAB MS. Resultant spectra generally show a dramatic increases in signal/chemical noise ratio of structurally significant ions when compared to normal FAB spectra

  9. Noise Source Identification of a Ring-Plate Cycloid Reducer Based on Coherence Analysis

    OpenAIRE

    Yang, Bing; Liu, Yan

    2013-01-01

    A ring-plate-type cycloid speed reducer is one of the most important reducers owing to its low volume, compactness, smooth and high performance, and high reliability. The vibration and noise tests of the reducer prototype are completed using the HEAD acoustics multichannel noise test and analysis system. The characteristics of the vibration and noise are obtained based on coherence analysis and the noise sources are identified. The conclusions provide the bases for further noise research and ...

  10. Vibration and noise analysis in nuclear power plants

    International Nuclear Information System (INIS)

    1974-12-01

    Results of the investigations on noise and vibration analysis are presented as a follow-up study of the work published in ''On-load Surveillance of Nuclear Power Plant Components by Noise and Vibration Analysis'' EUR 5036 e. The state of the art in on-load surveillance techniques of light water reactors is given by extending the preceding studies to investigations of boiling water reactors and by summarizing the latest results of pressurized water reactors, the basis being experimental and theoretical work performed by the different organizations involved in preparing this report. Finally, some developments with respect to measurement and identification methods are discussed

  11. Study on statistical analysis of nonlinear and nonstationary reactor noises

    International Nuclear Information System (INIS)

    Hayashi, Koji

    1993-03-01

    For the purpose of identification of nonlinear mechanism and diagnosis of nuclear reactor systems, analysis methods for nonlinear reactor noise have been studied. By adding newly developed approximate response function to GMDH, a conventional nonlinear identification method, a useful method for nonlinear spectral analysis and identification of nonlinear mechanism has been established. Measurement experiment and analysis were performed on the reactor power oscillation observed in the NSRR installed at the JAERI and the cause of the instability was clarified. Furthermore, the analysis and data recording methods for nonstationary noise have been studied. By improving the time resolution of instantaneous autoregressive spectrum, a method for monitoring and diagnosis of operational status of nuclear reactor has been established. A preprocessing system for recording of nonstationary reactor noise was developed and its usability was demonstrated through a measurement experiment. (author) 139 refs

  12. Application of autoregressive moving average model in reactor noise analysis

    International Nuclear Information System (INIS)

    Tran Dinh Tri

    1993-01-01

    The application of an autoregressive (AR) model to estimating noise measurements has achieved many successes in reactor noise analysis in the last ten years. The physical processes that take place in the nuclear reactor, however, are described by an autoregressive moving average (ARMA) model rather than by an AR model. Consequently more correct results could be obtained by applying the ARMA model instead of the AR model to reactor noise analysis. In this paper the system of the generalised Yule-Walker equations is derived from the equation of an ARMA model, then a method for its solution is given. Numerical results show the applications of the method proposed. (author)

  13. Noise Source Identification of a Ring-Plate Cycloid Reducer Based on Coherence Analysis

    Directory of Open Access Journals (Sweden)

    Bing Yang

    2013-01-01

    Full Text Available A ring-plate-type cycloid speed reducer is one of the most important reducers owing to its low volume, compactness, smooth and high performance, and high reliability. The vibration and noise tests of the reducer prototype are completed using the HEAD acoustics multichannel noise test and analysis system. The characteristics of the vibration and noise are obtained based on coherence analysis and the noise sources are identified. The conclusions provide the bases for further noise research and control of the ring-plate-type cycloid reducer.

  14. Diode laser pumped solid state laser. Part IV. ; Noise analysis. Handotai laser reiki kotai laser. 4. ; Noise kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, H.; Seno, T.; Tanabe, Y. (Asahi Glass Co. Ltd., Tokyo (Japan))

    1991-06-10

    Concerning the second harmonic generation(SHG) of diode laser pumped solid state laser using a nonlinear optical material, the researches are carried out to pracitically apply to the optical pickup. Therefore, the reduction of output optical noise has become the important researching subject. The theoretical and experimental analyses of noise generating mechanism were carried out for the system in which Nd;YAG as the laser diode and KTP (KTiOPO {sub 4}) as the nonlinear optical crystal were used. The following findings for the noise generating mechanism could be obtained: The competitive interaction between the polarization modes was dominant noise mechanism in the high frequency range from 1 to 20MHz and the noise could be removed sufficiently by using the QWP(quarter wave plate). On the other hand, the noise observed in the low frequency range from 100 to 200kHz depended on the resonance length, agreed qualitatively with the theoretical analysis of the noise to the competitive longitudinal modes and agreed quantitatively with the noise generating frequency range. 10 refs., 13 figs., 1 tab.

  15. Cascaded analysis of signal and noise propagation through a heterogeneous breast model

    International Nuclear Information System (INIS)

    Mainprize, James G.; Yaffe, Martin J.

    2010-01-01

    Purpose: The detectability of lesions in radiographic images can be impaired by patterns caused by the surrounding anatomic structures. The presence of such patterns is often referred to as anatomic noise. Others have previously extended signal and noise propagation theory to include variable background structure as an additional noise term and used in simulations for analysis by human and ideal observers. Here, the analytic forms of the signal and noise transfer are derived to obtain an exact expression for any input random distribution and the ''power law'' filter used to generate the texture of the tissue distribution. Methods: A cascaded analysis of propagation through a heterogeneous model is derived for x-ray projection through simulated heterogeneous backgrounds. This is achieved by considering transmission through the breast as a correlated amplification point process. The analytic forms of the cascaded analysis were compared to monoenergetic Monte Carlo simulations of x-ray propagation through power law structured backgrounds. Results: As expected, it was found that although the quantum noise power component scales linearly with the x-ray signal, the anatomic noise will scale with the square of the x-ray signal. There was a good agreement between results obtained using analytic expressions for the noise power and those from Monte Carlo simulations for different background textures, random input functions, and x-ray fluence. Conclusions: Analytic equations for the signal and noise properties of heterogeneous backgrounds were derived. These may be used in direct analysis or as a tool to validate simulations in evaluating detectability.

  16. Electrochemical evaluation of antibacterial drugs as environment-friendly inhibitors for corrosion of carbon steel in HCl solution

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Gh.; Shahidi, M., E-mail: shahidi1965@gmail.com; Ghazanfari, D.

    2014-07-01

    The effect of penicillin G, ampicillin and amoxicillin drugs on the corrosion behavior of carbon steel (ASTM 1015) in 1.0 mol L⁻¹ hydrochloric acid solution was investigated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) techniques. The inhibition efficiency was found to increase with increasing inhibitor concentration. The effect of temperature on the rate of corrosion in the absence and presence of these drugs was also studied. Some thermodynamic parameters were computed from the effect of temperature on corrosion and inhibition processes. Adsorption of these inhibitors was found to obey Langmuir adsorption isotherm. There was a case of mixed mode of adsorption here but while penicillin was adsorbed mainly through chemisorption, two other drugs were adsorbed mainly through physisorption. Potentiodynamic polarization measurements indicated that the inhibitors were of mixed type. In addition, this paper suggests that the electrochemical noise (EN) technique under open circuit conditions as the truly noninvasive electrochemical method can be employed for the quantitative evaluation of corrosion inhibition. This was done by using the standard deviation of partial signal (SDPS) for calculation of the amount of noise charges at the particular interval of frequency, thereby obtaining the inhibition efficiency (IE) of an inhibitor. These IE values showed a reasonable agreement with those obtained from potentiodynamic polarization and EIS measurements.

  17. Electrochemical evaluation of antibacterial drugs as environment-friendly inhibitors for corrosion of carbon steel in HCl solution

    International Nuclear Information System (INIS)

    Golestani, Gh.; Shahidi, M.; Ghazanfari, D.

    2014-01-01

    The effect of penicillin G, ampicillin and amoxicillin drugs on the corrosion behavior of carbon steel (ASTM 1015) in 1.0 mol L −1 hydrochloric acid solution was investigated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) techniques. The inhibition efficiency was found to increase with increasing inhibitor concentration. The effect of temperature on the rate of corrosion in the absence and presence of these drugs was also studied. Some thermodynamic parameters were computed from the effect of temperature on corrosion and inhibition processes. Adsorption of these inhibitors was found to obey Langmuir adsorption isotherm. There was a case of mixed mode of adsorption here but while penicillin was adsorbed mainly through chemisorption, two other drugs were adsorbed mainly through physisorption. Potentiodynamic polarization measurements indicated that the inhibitors were of mixed type. In addition, this paper suggests that the electrochemical noise (EN) technique under open circuit conditions as the truly noninvasive electrochemical method can be employed for the quantitative evaluation of corrosion inhibition. This was done by using the standard deviation of partial signal (SDPS) for calculation of the amount of noise charges at the particular interval of frequency, thereby obtaining the inhibition efficiency (IE) of an inhibitor. These IE values showed a reasonable agreement with those obtained from potentiodynamic polarization and EIS measurements.

  18. Dynamical noise filter and conditional entropy analysis in chaos synchronization.

    Science.gov (United States)

    Wang, Jiao; Lai, C-H

    2006-06-01

    It is shown that, in a chaotic synchronization system whose driving signal is exposed to channel noise, the estimation of the drive system states can be greatly improved by applying the dynamical noise filtering to the response system states. If the noise is bounded in a certain range, the estimation errors, i.e., the difference between the filtered responding states and the driving states, can be made arbitrarily small. This property can be used in designing an alternative digital communication scheme. An analysis based on the conditional entropy justifies the application of dynamical noise filtering in generating quality synchronization.

  19. Development and applications of reactor noise analysis at Ontario Hydro`s CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, O [Ontario Hydro, Toronto, ON (Canada); Tulett, M V [Ontario Hydro, Pickering, ON (Canada). Pickering Generating Station

    1996-12-31

    In 1992 a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro`s CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. The dynamic characteristics of critical plant components, instrumentation and processes are monitored on a regular basis. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes induced by moderator flow, (6) estimating the dynamics and response time of RTD (Resistance Temperature Detector) temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (10) detecting coolant boiling in fully instrumented fuel channels, (11) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as-needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology. (author

  20. Microfabricated Electrochemical Cell-Based Biosensors for Analysis of Living Cells In Vitro

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2012-04-01

    Full Text Available Cellular biochemical parameters can be used to reveal the physiological and functional information of various cells. Due to demonstrated high accuracy and non-invasiveness, electrochemical detection methods have been used for cell-based investigation. When combined with improved biosensor design and advanced measurement systems, the on-line biochemical analysis of living cells in vitro has been applied for biological mechanism study, drug screening and even environmental monitoring. In recent decades, new types of miniaturized electrochemical biosensor are emerging with the development of microfabrication technology. This review aims to give an overview of the microfabricated electrochemical cell-based biosensors, such as microelectrode arrays (MEA, the electric cell-substrate impedance sensing (ECIS technique, and the light addressable potentiometric sensor (LAPS. The details in their working principles, measurement systems, and applications in cell monitoring are covered. Driven by the need for high throughput and multi-parameter detection proposed by biomedicine, the development trends of electrochemical cell-based biosensors are also introduced, including newly developed integrated biosensors, and the application of nanotechnology and microfluidic technology.

  1. Realistic Noise Assessment and Strain Analysis of Iranian Permanent GPS Stations

    Science.gov (United States)

    Razeghi, S. M.; Amiri Simkooei, A. A.; Sharifi, M. A.

    2012-04-01

    To assess noise characteristics of Iranian Permanent GPS Stations (IPGS), northwestern part of this network namely Azerbaijan Continuous GPS Station (ACGS), was selected. For a realistic noise assessment it is required to model all deterministic signals of the GPS time series by means of least squares harmonic estimation (LS-HE) and derive all periodic behavior of the series. After taking all deterministic signals into account, the least squares variance component estimation (LS-VCE) is used to obtain a realistic noise model (white noise plus flicker noise) of the ACGS. For this purpose, one needs simultaneous GPS time series for which a multivariate noise assessment is applied. Having determined realistic noise model, a realistic strain analysis of the network is obtained for which one relies on the finite element methods. Finite element is now considered to be a new functional model and the new stochastic model is given based on the multivariate noise assessment using LS-VCE. The deformation rates of the components along with their full covariance matries are input to the strain analysis. Further, the results are also provided using a pure white noise model. The normalized strains for these two models show that the strain parameters derived from a realistic noise model are less significant than those derived from the white model. This could be either due to the short time span of the time series used or due to the intrinsic behavior of the strain parameters in the ACGS. Longer time series are required to further elaborate this issue.

  2. Simulation on a car interior aerodynamic noise control based on statistical energy analysis

    Science.gov (United States)

    Chen, Xin; Wang, Dengfeng; Ma, Zhengdong

    2012-09-01

    How to simulate interior aerodynamic noise accurately is an important question of a car interior noise reduction. The unsteady aerodynamic pressure on body surfaces is proved to be the key effect factor of car interior aerodynamic noise control in high frequency on high speed. In this paper, a detail statistical energy analysis (SEA) model is built. And the vibra-acoustic power inputs are loaded on the model for the valid result of car interior noise analysis. The model is the solid foundation for further optimization on car interior noise control. After the most sensitive subsystems for the power contribution to car interior noise are pointed by SEA comprehensive analysis, the sound pressure level of car interior aerodynamic noise can be reduced by improving their sound and damping characteristics. The further vehicle testing results show that it is available to improve the interior acoustic performance by using detailed SEA model, which comprised by more than 80 subsystems, with the unsteady aerodynamic pressure calculation on body surfaces and the materials improvement of sound/damping properties. It is able to acquire more than 2 dB reduction on the central frequency in the spectrum over 800 Hz. The proposed optimization method can be looked as a reference of car interior aerodynamic noise control by the detail SEA model integrated unsteady computational fluid dynamics (CFD) and sensitivity analysis of acoustic contribution.

  3. Toward the detection of gravitational waves under non-Gaussian noises II. Independent component analysis.

    Science.gov (United States)

    Morisaki, Soichiro; Yokoyama, Jun'ichi; Eda, Kazunari; Itoh, Yousuke

    2016-01-01

    We introduce a new analysis method to deal with stationary non-Gaussian noises in gravitational wave detectors in terms of the independent component analysis. First, we consider the simplest case where the detector outputs are linear combinations of the inputs, consisting of signals and various noises, and show that this method may be helpful to increase the signal-to-noise ratio. Next, we take into account the time delay between the inputs and the outputs. Finally, we extend our method to nonlinearly correlated noises and show that our method can identify the coupling coefficients and remove non-Gaussian noises. Although we focus on gravitational wave data analysis, our methods are applicable to the detection of any signals under non-Gaussian noises.

  4. Applications of noise analysis to nuclear safety

    International Nuclear Information System (INIS)

    Aguilar Martinez, Omar

    2000-01-01

    Noise Analysis techniques (analysis of the fluctuation of physical parameters) have been successfully applied to the operational vigilance of the technical equipment that plays a decisive role in the production cycle of a very complex industry. Although fluctuation measurements in nuclear installations started almost at the start of the nuclear era (see works by Feynman and Rossi on the development of neutron methodology), only recently have neutron noise diagnostic applications begun to be a part of the standard procedures for the performance of some modern nuclear installations. Following the relevant technical advances made in information sciences and analogical electronics, measuring the fluctuation of physical parameters has become a very effective tool for detecting, guarding and following up possible defects in a nuclear system. As the processing techniques for the fluctuation of a nuclear reactor's physical-neutron parameters have evolved (temporal and frequency analysis, multi-parameter self -regression analysis, etc.), the applications of the theory of non-lineal dynamics and chaos theory have progressed by focusing on the problem from another perspective. This work reports on those nuclear applications of noise analysis that increase nuclear safety in all types of nuclear facilities and that have been carried out by the author over the last decade, such as: -Void Force Critical Set Applications (Zero Power Reactor Applications, Central Institute of Physical Research, Budapest, Hungary); -Research Reactor Applications (Triga Mark III Reactor, National Institute of Nuclear Research, ININ, Mexico); -Power Reactor Applications in a Nuclear Power Plant (First Circuit of Block II, Paks Nuclear Center, Hungary); -Second Loop applications in a Nuclear Power Plant (Block I Paks Nuclear Center, Hungary; Block II Kalinin Nuclear Center, Russia); -Shield System Applications for the Transport of Radioisotopes (Nuclear Technology Center, Havana, Cuba) New trends in

  5. Electrochemical analysis of gold-coated magnetic nanoparticles for detecting immunological interaction

    International Nuclear Information System (INIS)

    Pham, Thao Thi-Hien; Sim, Sang Jun

    2010-01-01

    An electrochemical impedance immunosensor was developed for detecting the immunological interaction between human immunoglobulin (IgG) and protein A from Staphylococcus aureus based on the immobilization of human IgG on the surface of modified gold-coated magnetic nanoparticles. The nanoparticles with an Au shell and Fe oxide cores were functionalized by a self-assembled monolayer of 11-mercaptoundecanoic acid. The electrochemical analysis was conducted on the modified magnetic carbon paste electrodes with the nanoparticles. The magnetic nanoparticles were attached to the surface of the magnetic carbon paste electrodes via magnetic force. The cyclic voltammetry technique and electrochemical impedance spectroscopy measurements of the magnetic carbon paste electrodes coated with magnetic nanoparticles-human IgG complex showed changes in its alternating current (AC) response both after the modification of the surface of the electrode and the addition of protein A. The immunological interaction between human IgG on the surface of the modified magnetic carbon paste electrodes and protein A in the solution could be successfully monitored.

  6. Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography.

    Science.gov (United States)

    Waugh, William; Allen, John; Wightman, James; Sims, Andrew J; Beale, Thomas A W

    2018-01-01

    Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals.

  7. Coupled Mechanical-Electrochemical-Thermal Analysis of Failure Propagation in Lithium-ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chao; Santhanagopalan, Shriram; Pesaran, Ahmad

    2016-07-28

    This is a presentation given at the 12th World Congress for Computational Mechanics on coupled mechanical-electrochemical-thermal analysis of failure propagation in lithium-ion batteries for electric vehicles.

  8. Yesterday's noise - today's signal

    International Nuclear Information System (INIS)

    Serdula, K.J.

    1978-01-01

    Plant performance can be improved by noise analysis. This paper describes noise characteristics, imposed noise and response functions, a case history of cost benefits derived from application of noise analysis techniques, areas for application of noise analysis techniques with special reference to the Gentilly-1 nuclear generating station, and the validity of noise measurement results. (E.C.B.)

  9. Respondence Between Electrochemical Fluctuations and Phenomenon for Localized Corrosion of Less-Noble Metals

    International Nuclear Information System (INIS)

    Itoi, Yasuhiko; Take, Seisho; Tsuru, Tooru

    2008-01-01

    We have been studying application of electrochemical noise (Fluctuation) analysis for localized corrosion. Foils of Zinc, Aluminum and Magnesium were used as specimens for electrochemical cell simulating localized corrosion. These specimens were dipped in sodium chloride solutions adjusted to each exponent of hydrogen ion concentration (pH) condition of 5.5, 10, 12 respectively. Time variations of potential and current were measured in those solutions, and simultaneously the surfaces of specimens were observed using microscope with television monitor. Two types of electrochemical cells were arranged for experiments simulated localized corrosion. The fluctuations on trendy component of short-circuited potential and short-circuited current were appeared in synchronization. It was seemed that these fluctuations result from hydrogen evolution on the aluminum active site in the crevice from the microscopic observation. In the case of zinc and magnesium, fluctuations appeared on the trendy component of the corrosion potential. Two types fluctuation were detected. First one is the fluctuation varied periodically. The second one is the random fluctuation. It was seemed that these fluctuations result from generation of corrosion products and hydrogen evolution on the active site in the crevice of zinc and magnesium from the microscopic observation

  10. The Signal and Noise Analysis of Direct Conversion EHM Transceivers

    Directory of Open Access Journals (Sweden)

    Shayegh

    2006-01-01

    Full Text Available A direct conversion modulator-demodulator with even harmonic mixers with emphasis on noise analysis is presented. The circuits consist of even harmonic mixers (EHMs realized with antiparallel diode pairs (APDPs. We evaluate the different levels of I/Q imbalances and DC offsets and use signal space concepts to analyze the bit error rate (BER of the proposed transceiver using M-ary QAM schemes. Moreover, the simultaneous analysis of the signal and noise has been presented.

  11. Edge enhancement and noise suppression for infrared image based on feature analysis

    Science.gov (United States)

    Jiang, Meng

    2018-06-01

    Infrared images are often suffering from background noise, blurred edges, few details and low signal-to-noise ratios. To improve infrared image quality, it is essential to suppress noise and enhance edges simultaneously. To realize it in this paper, we propose a novel algorithm based on feature analysis in shearlet domain. Firstly, as one of multi-scale geometric analysis (MGA), we introduce the theory and superiority of shearlet transform. Secondly, after analyzing the defects of traditional thresholding technique to suppress noise, we propose a novel feature extraction distinguishing image structures from noise well and use it to improve the traditional thresholding technique. Thirdly, with computing the correlations between neighboring shearlet coefficients, the feature attribute maps identifying the weak detail and strong edges are completed to improve the generalized unsharped masking (GUM). At last, experiment results with infrared images captured in different scenes demonstrate that the proposed algorithm suppresses noise efficiently and enhances image edges adaptively.

  12. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  13. Noise characteristics analysis of short wave infrared InGaAs focal plane arrays

    Science.gov (United States)

    Yu, Chunlei; Li, Xue; Yang, Bo; Huang, Songlei; Shao, Xiumei; Zhang, Yaguang; Gong, Haimei

    2017-09-01

    The increasing application of InGaAs short wave infrared (SWIR) focal plane arrays (FPAs) in low light level imaging requires ultra-low noise FPAs. This paper presents the theoretical analysis of FPA noise, and point out that both dark current and detector capacitance strongly affect the FPA noise. The impact of dark current and detector capacitance on FPA noise is compared in different situations. In order to obtain low noise performance FPAs, the demand for reducing detector capacitance is higher especially when pixel pitch is smaller, integration time is shorter, and integration capacitance is larger. Several InGaAs FPAs were measured and analyzed, the experiments' results could be well fitted to the calculated results. The study found that the major contributor of FPA noise is coupled noise with shorter integration time. The influence of detector capacitance on FPA noise is more significant than that of dark current. To investigate the effect of detector performance on FPA noise, two kinds of photodiodes with different concentration of the absorption layer were fabricated. The detectors' performance and noise characteristics were measured and analyzed, the results are consistent with that of theoretical analysis.

  14. Sensitivity of PPI analysis to differences in noise reduction strategies.

    Science.gov (United States)

    Barton, M; Marecek, R; Rektor, I; Filip, P; Janousova, E; Mikl, M

    2015-09-30

    In some fields of fMRI data analysis, using correct methods for dealing with noise is crucial for achieving meaningful results. This paper provides a quantitative assessment of the effects of different preprocessing and noise filtering strategies on psychophysiological interactions (PPI) methods for analyzing fMRI data where noise management has not yet been established. Both real and simulated fMRI data were used to assess these effects. Four regions of interest (ROIs) were chosen for the PPI analysis on the basis of their engagement during two tasks. PPI analysis was performed for 32 different preprocessing and analysis settings, which included data filtering with RETROICOR or no such filtering; different filtering of the ROI "seed" signal with a nuisance data-driven time series; and the involvement of these data-driven time series in the subsequent PPI GLM analysis. The extent of the statistically significant results was quantified at the group level using simple descriptive statistics. Simulated data were generated to assess statistical improvement of different filtering strategies. We observed that different approaches for dealing with noise in PPI analysis yield differing results in real data. In simulated data, we found RETROICOR, seed signal filtering and the addition of data-driven covariates to the PPI design matrix significantly improves results. We recommend the use of RETROICOR, and data-driven filtering of the whole data, or alternatively, seed signal filtering with data-driven signals and the addition of data-driven covariates to the PPI design matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Noise analysis and performance of a selfscanned linear InSb detector array

    International Nuclear Information System (INIS)

    Finger, G.; Meyer, M.; Moorwood, A.F.M.

    1987-01-01

    A noise model for detectors operated in the capacitive discharge mode is presented. It is used to analyze the noise performance of the ESO nested timing readout technique applied to a linear 32-element InSb array which is multiplexed by a silicon switched-FET shift register. Analysis shows that KTC noise of the videoline is the major noise contribution; it can be eliminated by weighted double-correlated sampling. Best noise performance of this array is achieved at the smallest possible reverse bias voltage (not more than 20 mV) whereas excess noise is observed at higher reverse bias voltages. 5 references

  16. Report of the first United States conference on utility experience with neutron noise analysis

    International Nuclear Information System (INIS)

    Fry, D.N.; Horne, G.P.; Mayo, C.W.

    1984-01-01

    An informal meeting was held in Washington, D.C. on April 3 and 4, 1984, to discuss the current state of the art and experiences with neutron noise analysis in US pressurized water reactors (PWRs). The meeting was attended by 33 persons representing 11 utilities and 3 PWR reactor vendors as well as consultants, universities, and research laboratories. Presentations at the meeting covered several applications of neutron noise for diagnosing such things as vibrations induced by baffle jetting, detection of mechanical degradation of thermal shield supports, and electrical degradation of nuclear instrumentation channels. Twenty-one responses were obtained from a questionnaire circulated to all participants requesting their viewpoints and experiences regarding neutron noise analysis. The meeting participants concluded that a working group on neutron noise analysis should be formed to (1) establish a baseline library of neutron noise data, (2) provide a forum for communicating experiences with neutron noise surveillance, and (3) develop good practices and quality assurance procedures for neutron noise measurement and interpretation

  17. Spectro-electrochemical and DFT study of tenoxicam metabolites formed by electrochemical oxidation

    International Nuclear Information System (INIS)

    Ramírez-Silva, M.T.; Guzmán-Hernández, D.S.; Galano, A.; Rojas-Hernández, A.; Corona-Avendaño, S.; Romero-Romo, M.; Palomar-Pardavé, M.

    2013-01-01

    Highlights: • Tenoxicam deprotonation and electrochemical oxidation were studied. • Both spectro-electrochemical and theoretical DFT studies were considered. • It was found that the ampholitic species of tenoxicam is a zwitterion. • Electrochemical oxidation of tenoxicam yields two non-electroactive products. • The nature of these fragments was further confirmed by a chromatography study. -- Abstract: From experimental (spectro-electrochemical) and theoretical (DFT) studies, the mechanisms of tenoxicam deprotonation and electrochemical oxidation were assessed. From these studies, new insights on the nature of the ampholitic species involved during tenoxicam's deprotonation in aqueous solution are presented; see scheme A. Moreover, it is shown that, after the analysis of two different reaction schemes that involve up to 10 different molecules and 12 reaction paths, the electrochemical oxidation of tenoxicam, yields two non-electroactive products that are predominately formed by its fragmentation, after the loss of two electrons. The nature of these fragments was further confirmed by a chromatography study

  18. Reactor noise analysis of experimental fast reactor 'JOYO'

    International Nuclear Information System (INIS)

    Ohtani, Hideji; Yamamoto, Hisashi

    1980-01-01

    As a part of dynamics tests in experimental fast reactor ''JOYO'', reactor noise tests were carried out. The reactor noise analysis techniques are effective for study of plant characteristics by determining fluctuations of process signals (neutron signal, reactor inlet temperature signals, etc.), which are able to be measured without disturbances for reactor operations. The aims of reactor noise tests were to confirm that no unstable phenomenon exists in ''JOYO'' and to gain initial data of the plant for reference of the future data. Data for the reactor noise tests treated in this paper were obtained at 50 MW power level. Fluctuations of process signals were amplified and recorded on analogue tapes. The analysis was performed using noise code (NOISA) of digital computer, with which statistical values of ASPD (auto power spectral density), CPSD (cross power spectral density), and CF (coherence function) were calculated. The primary points of the results are as follows. 1. RMS value of neutron signal at 50 MW power level is about 0.03 MW. This neutron fluctuation is not disturbing reactor operations. 2. The fluctuations of A loop reactor inlet temperatures (T sub(AI)) are larger than the fluctuations of B loop reactor inlet temperature (T sub(BI)). For this reason, the major driving force of neutron fluctuations seems to be the fluctuations of T sub(AI). 3. Core and blanket subassemblies can be divided into two halves (A and B region), with respect to the spacial motion of temperature in the reactor core. A or B region means the region in which sodium temperature fluctuations in subassembly are significantly affected by T sub(AI) or T sub(BI), respectively. This phenomenon seems to be due to the lack of mixing of A and B loop sodium in lower plenum of reactor vessel. (author)

  19. Noise Measurement and Frequency Analysis of Commercially Available Noisy Toys

    Directory of Open Access Journals (Sweden)

    Shohreh Jalaie

    2005-06-01

    Full Text Available Objective: Noise measurement and frequency analysis of commercially available noisy toys were the main purposes of the study. Materials and Methods: 181 noisy toys commonly found in toy stores in different zones of Tehran were selected and categorized into 10 groups. Noise measurement were done at 2, 25, and 50 cm from toys in dBA. The noisiest toy of each group was frequency analyzed in octave bands. Results: The highest and the lowest intensity levels belonged to the gun (mean=112 dBA and range of 100-127 dBA and to the rattle-box (mean=84 dBA and range of 74-95 dBA, respectively. Noise intensity levels significantly decreased with increasing distance except for two toys. Noise frequency analysis indicated energy in effective hearing frequencies. Most of the toys energies were in the middle and high frequency region. Conclusion: As intensity level of the toys is considerable, mostly more than 90 dBA, and also their energy exist in the middle and high frequency region, toys should be considered as a cause of the hearing impairment.

  20. Digital signal processing for the Johnson noise thermometry: a time series analysis of the Johnson noise

    International Nuclear Information System (INIS)

    Moon, Byung Soo; Hwang, In Koo; Chung, Chong Eun; Kwon, Kee Choon; David, E. H.; Kisner, R.A.

    2004-06-01

    In this report, we first proved that a random signal obtained by taking the sum of a set of signal frequency signals generates a continuous Markov process. We used this random signal to simulate the Johnson noise and verified that the Johnson noise thermometry can be used to improve the measurements of the reactor coolant temperature within an accuracy of below 0.14%. Secondly, by using this random signal we determined the optimal sampling rate when the frequency band of the Johnson noise signal is given. Also the results of our examination on how good the linearity of the Johnson noise is and how large the relative error of the temperature could become when the temperature increases are described. Thirdly, the results of our analysis on a set of the Johnson noise signal blocks taken from a simple electric circuit are described. We showed that the properties of the continuous Markov process are satisfied even when some channel noises are present. Finally, we describe the algorithm we devised to handle the problem of the time lag in the long-term average or the moving average in a transient state. The algorithm is based on the Haar wavelet and is to estimate the transient temperature that has much smaller time delay. We have shown that the algorithm can track the transient temperature successfully

  1. Electrochemical and micro-gravimetric corrosion studies on spent fuel provide relevant source term data for a repository performance assessment

    International Nuclear Information System (INIS)

    Wegen, Detlef H.; Bottomley, Paul D. W.; Glatz, Jean-Paul

    2004-01-01

    Various electrochemical methods (corrosion potential monitoring, AC impedance analysis and electrochemical noise monitoring) were used in the investigation of UO 2 samples: natural and doped with two different levels of 238 Pu (0.1 and 10 wt%) simulating the increasing α-intensities seen with time in the repository. The results were compared and were able to show the intense, but also the very local nature of the radiolysis and to demonstrate that corrosion rates were proportional to α-radiolysis and hence the 238 Pu content; the corrosion rates were in accordance with earlier work at ITU. By contrast it was seen that the redox potentials only gave information as to the bulk solution that did not reflect the true conditions at the electrode interface that were driving the corrosion processes of UO 2 dissolution in groundwaters. The study shows how electrochemical techniques can provide vital information on the corrosion mechanism at the UO 2 /solution interface

  2. Spectrogram Image Analysis of Error Signals for Minimizing Impulse Noise

    Directory of Open Access Journals (Sweden)

    Jeakwan Kim

    2016-01-01

    Full Text Available This paper presents the theoretical and experimental study on the spectrogram image analysis of error signals for minimizing the impulse input noises in the active suppression of noise. Impulse inputs of some specific wave patterns as primary noises to a one-dimensional duct with the length of 1800 mm are shown. The convergence speed of the adaptive feedforward algorithm based on the least mean square approach was controlled by a normalized step size which was incorporated into the algorithm. The variations of the step size govern the stability as well as the convergence speed. Because of this reason, a normalized step size is introduced as a new method for the control of impulse noise. The spectrogram images which indicate the degree of the attenuation of the impulse input noises are considered to represent the attenuation with the new method. The algorithm is extensively investigated in both simulation and real-time control experiment. It is demonstrated that the suggested algorithm worked with a nice stability and performance against impulse noises. The results in this study can be used for practical active noise control systems.

  3. The effects of observational correlated noises on multifractal detrended fluctuation analysis

    Science.gov (United States)

    Gulich, Damián; Zunino, Luciano

    2012-08-01

    We have numerically investigated the effects that observational correlated noises have on the generalized Hurst exponents, h(q), estimated by using the multifractal generalization of detrended fluctuation analysis (MF-DFA). More precisely, artificially generated stochastic binomial multifractals with increased amount of colored noises were analyzed via MF-DFA. It has been recently shown that for moderate additions of white noise, the generalized Hurst exponents are significantly underestimated for qeffects of additive noise, short- term memory and periodic trends, Physica A 390 (2011) 2480-2490]. In this paper, we have found that h(q) with q≥2 are also affected when correlated noises are considered. This is due to the fact that the spurious correlations influence the scaling behaviors associated to large fluctuations. The results obtained are significant for practical situations, where noises with different correlations are inherently present.

  4. Corrosion behaviour of zinc and aluminum magnesium alloys by scanning reference electrode technique (SRET) and electrochemical noise (EN)

    International Nuclear Information System (INIS)

    Klassen, R.D.; Roberge, P.R.; Lafront, A.-M.; Oteyaka, M.O.; Ghali, E.

    2005-01-01

    The corrosion characteristics of five permanent mould magnesium alloys were studied. Two contained aluminum (AZ91D and AZ91E) and three contained zinc as the primary alloying element (ZA104 (Zn 10%, Al 4%), ZAC and ZACS). ZAC contained a small amount of calcium and ZACS contained small amounts of calcium and strontium. Two techniques were used in this study, namely 1) scanning reference electrode technique (SRET) and 2) electrochemical noise (EN). The test solution for each case was 5% NaCl saturated with Mg(OH)2 at room temperature. According to the EN measurements, the corrosion rate of AZ91D was the lowest followed by AZ91E, ZACS, ZAC and ZA104. The EN measurements showed that both the frequency and magnitude of current transients were much higher for the zinc based alloys than for the aluminum based alloys. The SRET measurements illustrated that localized corrosion occurred more frequently on the ZA104 sample than on the AZ91D sample. It seemed that increasing the level of zinc and lowering the level of aluminum relative to the levels in AZ91D does not improve corrosion resistance. (author)

  5. Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

    Science.gov (United States)

    Economou, Anastasios

    2018-03-29

    This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of "green" metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  6. Noise Analysis studies with neural networks

    International Nuclear Information System (INIS)

    Seker, S.; Ciftcioglu, O.

    1996-01-01

    Noise analysis studies with neural network are aimed. Stochastic signals at the input of the network are used to obtain an algorithmic multivariate stochastic signal modeling. To this end, lattice modeling of a stochastic signal is performed to obtain backward residual noise sources which are uncorrelated among themselves. There are applied together with an additional input to the network to obtain an algorithmic model which is used for signal detection for early failure in plant monitoring. The additional input provides the information to the network to minimize the difference between the signal and the network's one-step-ahead prediction. A stochastic algorithm is used for training where the errors reflecting the measurement error during the training are also modelled so that fast and consistent convergence of network's weights is obtained. The lattice structure coupled to neural network investigated with measured signals from an actual power plant. (authors)

  7. Properties of autoregressive model in reactor noise analysis, 1

    International Nuclear Information System (INIS)

    Yamada, Sumasu; Kishida, Kuniharu; Bekki, Keisuke.

    1987-01-01

    Under appropriate conditions, stochastic processes are described by the ARMA model, however, the AR model is popularly used in reactor noise analysis. Hence, the properties of AR model as an approximate representation of the ARMA model should be made clear. Here, convergence of AR-parameters and PSD of AR model were studied through numerical analysis on specific examples such as the neutron noise in subcritical reactors, and it was found that : (1) The convergence of AR-parameters and AR model PSD is governed by the ''zero nearest to the unit circle in the complex plane'' (μ -1 ,|μ| M . (3) The AR model of the neutron noise of subcritical reactors needs a large model order because of an ARMA-zero very close to unity corresponding to the decay constant of the 6-th group of delayed neutron precursors. (4) In applying AR model for system identification, much attention has to be paid to a priori unknown error as an approximate representation of the ARMA model in addition to the statistical errors. (author)

  8. Application of noise analysis to investigate core degradation process during PHEBUS-FPT1 test

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1997-01-01

    Noise analysis has been performed for measurement data obtained during PHEBUS-FPT1 test. The purpose of the study is to evaluate the applicability of the noise analysis to the following problems: To get more knowledge about the physical processes going on during severe core conditions; To better understand the core melting process; To establish appropriate on-line shut-down data. Results of the study indicate that the noise analysis is quite promising as a tool for investigating physical processes during the experiment. Compared with conventional approach of evaluating the signal's mean value behaviour, the noise analysis can provide additional, more detailed information: It was found that the neutron flux signal is subjected to additional reactivity perturbations in conjunction with fuel melting and relocation. This can easily be detected by applying noise analysis for the neutron flux signal. It has been demonstrated that the method developed in the present study can provide more accurate estimates of the onset of fuel relocation than using temperature signals from thermocouples in the thermal shroud. Moreover, the result suggests a potential of the present method for tracking the whole process of relocation. The result of the data analysis suggests a possibility of sensor diagnostics which may be important for confirming the quality and reliability of the recorded data. Based on the results achieved it is believed that the combined use of noise analysis and thermocouple signals will provide reliable shut-down criteria for the experiment. 8 refs

  9. Noise analysis of the Dodewaard boiling water reactor: characteristics and time history

    International Nuclear Information System (INIS)

    Veer, J.H.C. v.d.; Kema, N.V.

    1982-01-01

    Reactor noise measurements have been performed in the Dodewaard BWR since the eighth fuel cycle (1978). Analysis of the noise characteristics of the ex-core neutron detectors are reported. As a result characteristics of the global component of the boiling noise and the influence of oscillatory effects in reactor pressure control and steam flow rate are described. The influence of power feedback effects on the detection of global noise at low frequencies is given using point kinetic reactor theory. Results are reported on the behaviour of the neutron noise characteristics during one fuel cycle and on the behaviour from fuel cycle 8 to 11. (author)

  10. Davis Canyon noise analysis: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    A study was performed as part of the Civilian Radioactive Waste Management Program to quantify the level and effect of noise from the various major phases of development of the proposed potentially acceptable nuclear waste repository site at Davis Canyon, Utah. This report contains the results of a predictive noise level study for the site characterization, repository construction, and repository operational phases. Included herein are graphic representations of energy averaged sound levels, and of audibility levels representing impact zones expected during each phase. Sound levels from onsite and offsite activity including traffic on highways and railroad routes are presented in isopleth maps. A description of the Environmental Noise Prediction Model used for the study, the study basis and methodologies, and actual modeling data are provided. Noise and vibration levels from blasting are also predicted and evaluated. Protective noise criteria containing a margin of safety are used in relation to residences, schools, churches, noise-sensitive recreation areas, and noise-sensitive biological resources. Protective ground motion criteria for ruins and delicate rock formation in Canyonlands National Park and for human annoyance are used in the evaluation of blasting. The evaluations provide the basis for assessing the noise impacts from the related activities at the proposed repository. 45 refs., 21 figs., 15 tabs

  11. Analysis of sharpness increase by image noise

    Science.gov (United States)

    Kurihara, Takehito; Aoki, Naokazu; Kobayashi, Hiroyuki

    2009-02-01

    Motivated by the reported increase in sharpness by image noise, we investigated how noise affects sharpness perception. We first used natural images of tree bark with different amounts of noise to see whether noise enhances sharpness. Although the result showed sharpness decreased as noise amount increased, some observers seemed to perceive more sharpness with increasing noise, while the others did not. We next used 1D and 2D uni-frequency patterns as stimuli in an attempt to reduce such variability in the judgment. The result showed, for higher frequency stimuli, sharpness decreased as the noise amount increased, while sharpness of the lower frequency stimuli increased at a certain noise level. From this result, we thought image noise might reduce sharpness at edges, but be able to improve sharpness of lower frequency component or texture in image. To prove this prediction, we experimented again with the natural image used in the first experiment. Stimuli were made by applying noise separately to edge or to texture part of the image. The result showed noise, when added to edge region, only decreased sharpness, whereas when added to texture, could improve sharpness. We think it is the interaction between noise and texture that sharpens image.

  12. Noise analysis of switched integrator preamplifiers

    International Nuclear Information System (INIS)

    Sun Hongbo; Li Yulan; Zhu Weibin

    2004-01-01

    The main noise sources of switched integrator preamplifiers are discussed, and their noise performance are given combined PSpice simulation and experiments on them. Then, some practical methods on how to reduce noise of preamplifiers in two different integrator modes are provided. (authors)

  13. Power reactor noise

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    This book concentrates on the different types of noise present in power reactors and how the analysis of this noise can be used as a tool for reactor monitoring and diagnostics. Noise analysis is a growing field that offers advantages such as simplicity, low cost, and natural multivariable interactions. A major advantage, continuous and undisturbed monitoring, supplies a means of obtaining early warnings of possible reactor malfunctions thus preventing further complications by alerting operators to a problem - and aiding in the diagnosis of that problem - before it demands major repairs. Following an introductory chapter, the theoretical basis for the various methods of noise analysis is explained, and full chapters are devoted to the fundamentals of statistics for time-domain analysis and Fourier series and related topics for frequency-domain analysis. General experimental techniques and associated theoretical considerations are reviewed, leading to discussion of practical applications in the latter half of the book. Besides chapters giving examples of neutron noise and acoustical noise, chapters are also devoted to extensive examples from pressurized water reactor and boiling water reactor power plants

  14. The nonlinear treatment in noise analysis and its influence into quality programs

    International Nuclear Information System (INIS)

    Montesino, Maria Elena; Piedra, Margarita; Rolo, Alberto

    2002-01-01

    Analysis by noise technique have been utilized in fact for early detection reactor's anomalies, constituting one of the fundamental tools in maintenance condition. There is an international tendency to use this technique in order to guarantee the quality of maintenance control at present. Essentially this technique is an approach from lineal dynamic and insufficient for limit cycle illustrations, which take place after bifurcation point. As non-lineal dynamic (chaos theory) descriptors consider the dynamic characteristics of studied system, their uses guarantee the quality in predictive maintenance by noise. In this paper was analysed the necessity of theory's use as a tool to supplement the analysis by noise technique. (author)

  15. NOASYS, a system for on-line noise analysis

    International Nuclear Information System (INIS)

    Massier, H.

    1978-07-01

    This report describes NOASYS, a versatile NOise Analysis SYStem for digital on-line signal processing. The system based on a minicomputer, was originally developed for the analysis of noise signals from nuclear reactors. NOASYS computes various statistical functions e.g. cross- und auto-correlation functions and power spectral densities resp., which may be used for reactor diagnosis and malfunction detection. The system processes up to 16 analog signals with a maximum sampling frequency of 100 kcps (1 channel). The processing of the sampled data is done by a number of software tasks, which may be called from a teletype or linked together for specific measuring programs. The standard configuration contains the often used processing routines e.g. Fast Fourier Transform, complex multiplication, summation etc. In addition NOASYS may be extended by users own tasks (in Assembler or Fortran) to fit for specific applications. (orig.) 891 HP [de

  16. Noise removing in encrypted color images by statistical analysis

    Science.gov (United States)

    Islam, N.; Puech, W.

    2012-03-01

    Cryptographic techniques are used to secure confidential data from unauthorized access but these techniques are very sensitive to noise. A single bit change in encrypted data can have catastrophic impact over the decrypted data. This paper addresses the problem of removing bit error in visual data which are encrypted using AES algorithm in the CBC mode. In order to remove the noise, a method is proposed which is based on the statistical analysis of each block during the decryption. The proposed method exploits local statistics of the visual data and confusion/diffusion properties of the encryption algorithm to remove the errors. Experimental results show that the proposed method can be used at the receiving end for the possible solution for noise removing in visual data in encrypted domain.

  17. Noise Analysis of Switched-Current Circuits

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger; Bogason, Gudmundur

    1998-01-01

    The understanding of noise in analog sampled data systems is vital for the design of high resolution circuitry. In this paper a general description of sampled and held noise is presented. The noise calculations are verified by measurements on an analog delay line implemented using switched...

  18. Analysis of Noise Mechanisms in Cell-Size Control.

    Science.gov (United States)

    Modi, Saurabh; Vargas-Garcia, Cesar Augusto; Ghusinga, Khem Raj; Singh, Abhyudai

    2017-06-06

    At the single-cell level, noise arises from multiple sources, such as inherent stochasticity of biomolecular processes, random partitioning of resources at division, and fluctuations in cellular growth rates. How these diverse noise mechanisms combine to drive variations in cell size within an isoclonal population is not well understood. Here, we investigate the contributions of different noise sources in well-known paradigms of cell-size control, such as adder (division occurs after adding a fixed size from birth), sizer (division occurs after reaching a size threshold), and timer (division occurs after a fixed time from birth). Analysis reveals that variation in cell size is most sensitive to errors in partitioning of volume among daughter cells, and not surprisingly, this process is well regulated among microbes. Moreover, depending on the dominant noise mechanism, different size-control strategies (or a combination of them) provide efficient buffering of size variations. We further explore mixer models of size control, where a timer phase precedes/follows an adder, as has been proposed in Caulobacter crescentus. Although mixing a timer and an adder can sometimes attenuate size variations, it invariably leads to higher-order moments growing unboundedly over time. This results in a power-law distribution for the cell size, with an exponent that depends inversely on the noise in the timer phase. Consistent with theory, we find evidence of power-law statistics in the tail of C. crescentus cell-size distribution, although there is a discrepancy between the observed power-law exponent and that predicted from the noise parameters. The discrepancy, however, is removed after data reveal that the size added by individual newborns in the adder phase itself exhibits power-law statistics. Taken together, this study provides key insights into the role of noise mechanisms in size homeostasis, and suggests an inextricable link between timer-based models of size control and

  19. Noise Analysis of Switched-Current Circuits

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger; Bogason, Gudmundur

    1999-01-01

    The understanding of noise in analog sampled data systems is vital for the design of high resolution circuitry in the discrete time domain. In this paper a general description of sampled and held noise is presened. The noise calculations are verified by measurements on an analog delay line implem...

  20. Electrochemical biosensors in pharmaceutical analysis

    Directory of Open Access Journals (Sweden)

    Eric de Souza Gil

    2010-09-01

    Full Text Available Given the increasing demand for practical and low-cost analytical techniques, biosensors have attracted attention for use in the quality analysis of drugs, medicines, and other analytes of interest in the pharmaceutical area. Biosensors allow quantification not only of the active component in pharmaceutical formulations, but also the analysis of degradation products and metabolites in biological fluids. Thus, this article presents a brief review of biosensor use in pharmaceutical analysis, focusing on enzymatic electrochemical sensors.Em virtude do aumento da demanda por técnicas analíticas simples e de baixo custo, os biossensores têm atraído a atenção para a análise de fármacos, medicamentos e outros analitos de interesse em controle de qualidade de medicamentos. Os biossensores permitem a quantificação não somente de princípio ativo em formulações farmacêuticas, mas também de produtos de degradação e metabólitos em fluídos biológicos, bem como análise de amostras de interesse clínico e industrial, além de possibilitar a determinação de enantiômeros. Desta forma, este artigo objetiva fazer uma breve revisão a respeito do emprego de biossensores em análise farmacêutica, com ênfase em sensores eletroquímicos enzimáticos.

  1. Noise Analysis of Single-Ended Input Differential Amplifier using Stochastic Differential Equation

    OpenAIRE

    Tarun Kumar Rawat; Abhirup Lahiri; Ashish Gupta

    2008-01-01

    In this paper, we analyze the effect of noise in a single- ended input differential amplifier working at high frequencies. Both extrinsic and intrinsic noise are analyzed using time domain method employing techniques from stochastic calculus. Stochastic differential equations are used to obtain autocorrelation functions of the output noise voltage and other solution statistics like mean and variance. The analysis leads to important design implications and suggests changes in the device parame...

  2. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    Directory of Open Access Journals (Sweden)

    Anastasios Economou

    2018-03-01

    Full Text Available This work reviews the field of screen-printed electrodes (SPEs modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of “green” metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  3. Experiment and Simulation Analysis on Noise Attenuation of Al/MF Cylindrical Shells

    Directory of Open Access Journals (Sweden)

    Bin Li

    2017-01-01

    Full Text Available For the issue concerning internal noise reduction of Al-made cylindrical shell structure, the noise control method of laying melamine foam (MF layer is adopted for in-shell noise attenuation experiments of Al and Al/MF cylindrical shells and corresponding internal noise response spectrograms are obtained. Based on the Virtual.Lab acoustics software, a finite element model is established for the analysis of noise in the Al/MF cylinder shell and numerical simulation computation is conducted for the acoustic mode and in-shell acoustic response; the correctness of the finite element model is verified via comparison with measured data. On this basis, influence rules of different MF laying rate and different laying thickness on acoustic cavity resonance response within the low and medium frequency range of 100–400 Hz are studied. It is indicated that noise reduction increases with MF laying rate, but the amplification decreases along with the rising of MF laying rate; noise reduction per unit thickness decreases with the increase of laying thickness, while noise reduction per unit area increases.

  4. Signal Processing for MoC brake rattle noise of moving vehicles using prony analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Cheol; Kwak, Yun Sang; Park, Jun Hong [Dept. of Mechanical Convergence Engineering, Hanyang University, Seoul (Korea, Republic of)

    2015-08-15

    To verify the possibility of generating rattling noise from a motor on caliper brake system, a test was conducted using a caliper excited with vibrations similar to that in a vehicle running on actual roads; this test was conducted using a quiet shaker installed in an anechoic room. After several hours of external excitation, the test assembly was loosened, and the frequency of rattling noise generation increased. A microphone was used to record the generated noise. The measured signals were analyzed by conventional spectrum analysis. Since the noise is generated as an impact response, the advantages of employing Prony analysis was discussed, and the results were compared to those obtained using conventional fast Fourier transforms. The accuracy of Prony analysis was through endurance tests on different brake systems.

  5. On the role of magnetic field intensity for better micro-structural characterization during Barkhausen Noise analysis

    Science.gov (United States)

    Yusufzai, Mohd Zaheer Khan; Vashista, M.

    2018-04-01

    Barkhausen Noise analysis is a popular and preferred technique for micro-structural characterization. The root mean square value and peak value of Barkhausen Noise burst are important parameters to assess the micro-hardness and residual stress. Barkhausen Noise burst can be enveloped using a curve known as Barkhausen Noise profile. Peak position of profile changes with change in micro-structure. In the present work, raw signal of Barkhausen Noise burst was obtained from Ni based sample at various magnetic field intensity to observe the effect of variation in field intensity on Barkhausen Noise burst. Raw signal was opened using MATLAB to further process for microstructure analysis. Barkhausen Noise analysis parameters such as magnetizing frequency, number of burst, high pass and low pass filter frequency were kept constant and magnetizing field was varied in wide range between 200 Oe to 1200 Oe. The processed profiles of Barkhausen Noise burst obtained at various magnetizing field intensity clearly reveals requirement of optimum magnetic field strength for better characterization of micro-structure.

  6. Electrochemical Noise Sensors for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines. Final Report for the Period July 2001-October 2002

    Energy Technology Data Exchange (ETDEWEB)

    Bullard, Sophie J.; Covino, Jr., Bernard S.; Russell, James H.; Holcomb, Gordon R.; Cramer, Stephen D.; Ziomek-Moroz, Margaret

    2002-12-01

    The U.S. Department of Energy, National Energy Technology Laboratory funded a Natural Gas Infrastructure Reliability program directed at increasing and enhancing research and development activities in topics such as remote leak detection, pipe inspection, and repair technologies and materials. The Albany Research Center (ARC), U.S. Department of Energy was funded to study the use of electrochemical noise sensors for detection of localized and general corrosion of natural gas transmission pipelines. As part of this, ARC entered into a collaborative effort with the corrosion sensor industry to demonstrate the capabilities of commercially available remote corrosion sensors for use with the Nation's Gas Transmission Pipeline Infrastructure needs. The goal of the research was to develop an emerging corrosion sensor technology into a monitor for the type and degree of corrosion occurring at key locations in gas transmission pipelines.

  7. Application of neutron noise analysis to a swimming pool research reactor

    International Nuclear Information System (INIS)

    Behringer, K.; Lescano, V.H.; Meier, F.; Phildius, J.; Winkler, H.

    1982-01-01

    This work is part of a programme of establishing practical applications of neutron noise techniques to a swimming pool research reactor and deals with two different items: (1) The identification of local boiling caused e.g. by a partial blockage of the coolant flow in a fuel element. Local boiling can easily lead to a burn-out situation. The onset of boiling can be detected by neutron noise analysis and a boiling detection system is presently under development. (2) The measurement of the time evolution of the reactivity induced by xenon after reactor shut-down by an on-line reactivity meter based on neutron noise analysis. From the data, the prompt neutron decay constant at delayed critical, the equilibrium xenon reactivity worth, and an estimate of the average steady-state power flux in the core before reactor shut-down were obtained. (author)

  8. Orbiter CCTV video signal noise analysis

    Science.gov (United States)

    Lawton, R. M.; Blanke, L. R.; Pannett, R. F.

    1977-01-01

    The amount of steady state and transient noise which will couple to orbiter CCTV video signal wiring is predicted. The primary emphasis is on the interim system, however, some predictions are made concerning the operational system wiring in the cabin area. Noise sources considered are RF fields from on board transmitters, precipitation static, induced lightning currents, and induced noise from adjacent wiring. The most significant source is noise coupled to video circuits from associated circuits in common connectors. Video signal crosstalk is the primary cause of steady state interference, and mechanically switched control functions cause the largest induced transients.

  9. Quantitative analysis of the anti-noise performance of an m-sequence in an electromagnetic method

    Science.gov (United States)

    Yuan, Zhe; Zhang, Yiming; Zheng, Qijia

    2018-02-01

    An electromagnetic method with a transmitted waveform coded by an m-sequence achieved better anti-noise performance compared to the conventional manner with a square-wave. The anti-noise performance of the m-sequence varied with multiple coding parameters; hence, a quantitative analysis of the anti-noise performance for m-sequences with different coding parameters was required to optimize them. This paper proposes the concept of an identification system, with the identified Earth impulse response obtained by measuring the system output with the input of the voltage response. A quantitative analysis of the anti-noise performance of the m-sequence was achieved by analyzing the amplitude-frequency response of the corresponding identification system. The effects of the coding parameters on the anti-noise performance are summarized by numerical simulation, and their optimization is further discussed in our conclusions; the validity of the conclusions is further verified by field experiment. The quantitative analysis method proposed in this paper provides a new insight into the anti-noise mechanism of the m-sequence, and could be used to evaluate the anti-noise performance of artificial sources in other time-domain exploration methods, such as the seismic method.

  10. Noise source analysis of nuclear ship Mutsu plant using multivariate autoregressive model

    International Nuclear Information System (INIS)

    Hayashi, K.; Shimazaki, J.; Shinohara, Y.

    1996-01-01

    The present study is concerned with the noise sources in N.S. Mutsu reactor plant. The noise experiments on the Mutsu plant were performed in order to investigate the plant dynamics and the effect of sea condition and and ship motion on the plant. The reactor noise signals as well as the ship motion signals were analyzed by a multivariable autoregressive (MAR) modeling method to clarify the noise sources in the reactor plant. It was confirmed from the analysis results that most of the plant variables were affected mainly by a horizontal component of the ship motion, that is the sway, through vibrations of the plant structures. Furthermore, the effect of ship motion on the reactor power was evaluated through the analysis of wave components extracted by a geometrical transform method. It was concluded that the amplitude of the reactor power oscillation was about 0.15% in normal sea condition, which was small enough for safe operation of the reactor plant. (authors)

  11. Electrochemical Impedance Spectroscopic Analysis of RuO2 Based Thick Film pH Sensors

    International Nuclear Information System (INIS)

    Manjakkal, Libu; Djurdjic, Elvira; Cvejin, Katarina; Kulawik, Jan; Zaraska, Krzysztof; Szwagierczak, Dorota

    2015-01-01

    The conductimetric interdigitated thick film pH sensors based on RuO 2 were fabricated and their electrochemical reactions with solutions of different pH values were studied by electrochemical impedance spectroscopy (EIS) technique. The microstructural properties and composition of the sensitive films were examined by scanning electron microscopy, X-ray energy dispersive spectroscopy and Raman spectroscopy. The EIS analysis of the sensor was carried out in the frequency range 10 mHz–2 MHz for pH values of test solutions 2–12. The electrical parameters of the sensor were found to vary with changing pH. The conductance and capacitance of the film were distinctly dependent on pH in the low frequency range. The Nyquist and Bode plots derived from the impedance data for the metal oxide thick film pH sensor provided information about the underlying electrochemical reactions

  12. Noise Gating Solar Images

    Science.gov (United States)

    DeForest, Craig; Seaton, Daniel B.; Darnell, John A.

    2017-08-01

    I present and demonstrate a new, general purpose post-processing technique, "3D noise gating", that can reduce image noise by an order of magnitude or more without effective loss of spatial or temporal resolution in typical solar applications.Nearly all scientific images are, ultimately, limited by noise. Noise can be direct Poisson "shot noise" from photon counting effects, or introduced by other means such as detector read noise. Noise is typically represented as a random variable (perhaps with location- or image-dependent characteristics) that is sampled once per pixel or once per resolution element of an image sequence. Noise limits many aspects of image analysis, including photometry, spatiotemporal resolution, feature identification, morphology extraction, and background modeling and separation.Identifying and separating noise from image signal is difficult. The common practice of blurring in space and/or time works because most image "signal" is concentrated in the low Fourier components of an image, while noise is evenly distributed. Blurring in space and/or time attenuates the high spatial and temporal frequencies, reducing noise at the expense of also attenuating image detail. Noise-gating exploits the same property -- "coherence" -- that we use to identify features in images, to separate image features from noise.Processing image sequences through 3-D noise gating results in spectacular (more than 10x) improvements in signal-to-noise ratio, while not blurring bright, resolved features in either space or time. This improves most types of image analysis, including feature identification, time sequence extraction, absolute and relative photometry (including differential emission measure analysis), feature tracking, computer vision, correlation tracking, background modeling, cross-scale analysis, visual display/presentation, and image compression.I will introduce noise gating, describe the method, and show examples from several instruments (including SDO

  13. Aggregation of Individual Sensing Units for Signal Accumulation: Conversion of Liquid-Phase Colorimetric Assay into Enhanced Surface-Tethered Electrochemical Analysis.

    Science.gov (United States)

    Wei, Tianxiang; Dong, Tingting; Wang, Zhaoyin; Bao, Jianchun; Tu, Wenwen; Dai, Zhihui

    2015-07-22

    A novel concept is proposed for converting liquid-phase colorimetric assay into enhanced surface-tethered electrochemical analysis, which is based on the analyte-induced formation of a network architecture of metal nanoparticles (MNs). In a proof-of-concept trial, thymine-functionalized silver nanoparticle (Ag-T) is designed as the sensing unit for Hg(2+) determination. Through a specific T-Hg(2+)-T coordination, the validation system based on functionalized sensing units not only can perform well in a colorimetric Hg(2+) assay, but also can be developed into a more sensitive and stable electrochemical Hg(2+) sensor. In electrochemical analysis, the simple principle of analyte-induced aggregation of MNs can be used as a dual signal amplification strategy for significantly improving the detection sensitivity. More importantly, those numerous and diverse colorimetric assays that rely on the target-induced aggregation of MNs can be augmented to satisfy the ambitious demands of sensitive analysis by converting them into electrochemical assays via this approach.

  14. Application of the neutron noise analysis technique in nuclear power plants

    International Nuclear Information System (INIS)

    Lescano, Victor H.; Wentzeis, Luis M.

    1999-01-01

    Using the neutron noise analysis in nuclear power plants, and without producing any perturbation in the normal operation of the plant, information of the vibration state of the reactor internals and the behavior of the operating conditions of the reactor primary circuit can be obtained. In Argentina, the neutron noise analysis technique is applied in customary way in the nuclear power plants Atucha I and Embalse. A database was constructed and vibration frequencies corresponding to different reactor internals were characterized. Reactor internals with particular mechanical vibrations have been detected and localized. In the framing of a cooperation project between Argentina and Germany, we participated in the measurements, analysis and modelisation, using the neutron noise technique, in the Obrigheim and Gundremmingen nuclear power plants. In the nuclear power plant Obrigheim (PWR, 350 M We), correlations between the signals measured from self-power neutron detectors and accelerometers located inside the reactor core, were made. In the nuclear power plant Gundremmingen (BWR, 1200 M We) we participated in the study of a particular mechanical vibration detected in one of the instrumentation tube. (author)

  15. Electrochemical biosensors for hormone analyses.

    Science.gov (United States)

    Bahadır, Elif Burcu; Sezgintürk, Mustafa Kemal

    2015-06-15

    Electrochemical biosensors have a unique place in determination of hormones due to simplicity, sensitivity, portability and ease of operation. Unlike chromatographic techniques, electrochemical techniques used do not require pre-treatment. Electrochemical biosensors are based on amperometric, potentiometric, impedimetric, and conductometric principle. Amperometric technique is a commonly used one. Although electrochemical biosensors offer a great selectivity and sensitivity for early clinical analysis, the poor reproducible results, difficult regeneration steps remain primary challenges to the commercialization of these biosensors. This review summarizes electrochemical (amperometric, potentiometric, impedimetric and conductometric) biosensors for hormone detection for the first time in the literature. After a brief description of the hormones, the immobilization steps and analytical performance of these biosensors are summarized. Linear ranges, LODs, reproducibilities, regenerations of developed biosensors are compared. Future outlooks in this area are also discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Richton Dome noise analysis: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    A study was performed as part of the Civilian Radioactive Waste Management Program to quantify the level and effect of noise from the various major phases of development of the proposed potentially acceptable nuclear waste repository site at Richton Dome, Mississippi. This report contains the results of a predictive noise level study for the site characterization, repository construction, and repository operational phases. Included herein are graphic representations of energy averaged day/night sound levels representing impact zones expected during each phase. Sound levels from onsite and offsite activity including traffic on highways and railroad routes are presented in isopleth maps. A description of the Environmental Noise Prediction Model used for the study, the study basis and methodologies, and actual modeling data are provided. Noise and vibration levels from blasting are also predicted and evaluated. Protective noise criteria containing a margin of safety are used for persons in relation to residences, schools, churches, and agricultural areas. Protective ground motion criteria for residential dwelling and for human annoyance are used in the evaluation. The evaluation provides the bases for assessing the noise impacts from the related activities at the proposed repository. 24 refs., 8 figs., 8 tabs

  17. Development of Advanced Electrochemical Emission Spectroscopy for Monitoring Corrosion in Simulated DOE Liquid Waste

    Energy Technology Data Exchange (ETDEWEB)

    Digby Macdonald; Brian Marx; Balaji Soundararajan; Morgan Smith

    2005-07-28

    The different tasks that have been carried out under the current program are as follows: (1) Theoretical and experimental assessment of general corrosion of iron/steel in borate buffer solutions by using electrochemical impedance spectroscopy (EIS), ellipsometry and XPS techniques; (2) Development of a damage function analysis (DFA), which would help in predicting the accumulation of damage due to pitting corrosion in an environment prototypical of DOE liquid waste systems; (3) Experimental measurement of crack growth rate, acoustic emission signals, and coupling currents for fracture in carbon and low alloy steels as functions of mechanical (stress intensity), chemical (conductivity), electrochemical (corrosion potential, ECP), and microstructural (grain size, precipitate size, etc) variables in a systematic manner, with particular attention being focused on the structure of the noise in the current and its correlation with the acoustic emissions; (4) Development of fracture mechanisms for carbon and low alloy steels that are consistent with the crack growth rate, coupling current data and acoustic emissions; (5) Inserting advanced crack growth rate models for SCC into existing deterministic codes for predicting the evolution of corrosion damage in DOE liquid waste storage tanks; (6) Computer simulation of the anodic and cathodic activity on the surface of the steel samples in order to exactly predict the corrosion mechanisms; (7) Wavelet analysis of EC noise data from steel samples undergoing corrosion in an environment similar to that of the high level waste storage containers, to extract data pertaining to general, pitting and stress corrosion processes, from the overall data. The work has yielded a number of important findings, including an unequivocal demonstration of the role of chloride ion in passivity breakdown on nickel in terms of cation vacancy generation within the passive film, the first detection and characterization of individual micro fracture

  18. Evaluation and Analysis of Road Traffic Noise in Asansol: An Industrial Town of Eastern India

    Directory of Open Access Journals (Sweden)

    A. Gangopadhyay

    2008-09-01

    Full Text Available The objectives of the study were to monitor and assess the road traffic noise in its spatial-temporal aspect in an urban area. The paper discusses the observations, results and their interpretation based on the study. Noise recordings from site, collected from April 2006 to March 2006, were used for statistical analysis and generation of various noise indices. Noise maps were also created for impact analysis and formulation of Noise Risk Zones. Mean Ldn value ranged between 55.1 and 87.3 dB (A. Day time Leq level ranged between 51.2 and 89.0 dB (A, where it ranged between 43.5 and 81.9 dB (A during night. The study reveals that present noise level in all the locations exceeds the limit prescribed by CPCB. Based on the finding it can be said that the population in this industrial town are exposed to significantly high noise level, which is caused mostly due to road traffic.

  19. Power reactor noise

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Noise analysis is a growing field that offers advantages such as simplicity, low cost, and natural multivariable interactions. A major advantage, continuous and undisturbed monitoring, supplies a means of obtaining early warnings of possible reactor malfunctions, thus preventing further complications by alerting opeators to a problem - and aiding in the diagnosis of that problem - before it demands major repairs. Dr. Thie hopes to further, through detailed explanations and over 70 illustrations, the acceptance of the use of noise analysis by the nuclear utility industry. Following an introductory chapter, the theoretical basis for the various methods of noise analysis is explained, and full chapters are devoted to the fundamentals of statistics for time-domain analysis and Fourier series and related topics for frequency-domain analysis. General experimental techniques and associated theoretical considerations are reviewed, leading to discussions of practical applications in the latter half of the book. Besides chapters giving examples of neutron noise and acoustical noise, chapters are also devoted to extensive examples from pressurized water reactor and boiling water reactor power plants

  20. Summary of the fourth conference on United States utility experience in reactor noise analysis

    International Nuclear Information System (INIS)

    Fry, D.N.

    1987-01-01

    The fourth informal conference on United States utility experience in reactor noise analysis and loose-part monitoring was held at the Northeast Utilities Service Company offices in Hartford, Connecticut, May 12-14, 1987. Host and general chairman for the meeting was J.V. Persio of Northeast Utilities. This conference provided a forum where utilities could share information on reactor noise analysis on an informal basis. There were about 60 attendees at the meeting representing 10 utilities, 3 reactor vendors, 8 consulting organizations, and 4 universities and research laboratories. Twenty-three papers were presented at the conference, dealing with various aspects of loose-part monitoring, neutron noise analysis, and standards activities

  1. Current applications of vibration monitoring and neutron noise analysis

    International Nuclear Information System (INIS)

    Damiano, B.; Kryter, R.C.

    1990-02-01

    Monitoring programs using vibration monitoring or neutron noise analysis have demonstrated the ability to detect and, in some cases, diagnose the nature of reactor vessel internals structural degradation. Detection of compromised mechanical integrity of reactor vessel internal components in its early stages allows corrective action to be taken before weakening or damage occurs. In addition to the economic benefits early detection and correction can provide, they can also help maintain plant safety. Information on the condition of reactor vessel internal components gained from a monitoring program supplements in-service inspection results and may be useful in justifying plant license extension. This report, which was prepared under the Nuclear Plant Aging Research Program sponsored by the US Nuclear Regulatory Commission, discusses the application of vibration monitoring and neutron noise analysis for monitoring light-water reactor vessel internals. The report begins by describing the effects of structural integrity loss on internals vibration and how measurable parameters can be used to detect and track the progress of degradation. This is followed by a description and comparison of vibration monitoring and neutron noise analysis, two methods for monitoring the mechanical integrity of reactor vessel internals condition monitoring programs in the United States, Federal Republic of Germany, and France, three countries having substantial commitments to nuclear power. The last section presents guidelines for US utilities wishing to establish reactor internals condition monitoring programs. 20 refs., 5 figs., 4 tabs

  2. Electrochemical Detection with Preconcentration: Nitroenergetic Contaminants

    Directory of Open Access Journals (Sweden)

    Brandy J. Johnson

    2014-06-01

    Full Text Available This effort evaluated the potential of two prototype devices for enhanced electrochemical detection of 2,4,6-trinitrotoluene (TNT and dinitrotoluene (DNT following preconcentration using an organosilicate sorbent. The bench-scale prototype provides adsorption of the targets from aqueous solution followed by elution in a mixture of methanol and potassium chloride (KCl. Following elution, the eluant is diluted using an aqueous KCl solution to provide sufficient electrolyte for electrochemical analysis. Concentrations of methanol greater than 50% were detrimental to sensor performance and lifetime. Calibration of the electrochemical sensor was completed and results of electrochemical analysis were compared to those of HPLC analysis over a range of concentrations and in varied matrices. TNT detection was found to be consistent and detection limits were improved from 200 ppb to 3 ppb depending on the sample volume utilized. DNT detection showed higher variability and significantly greater false response rates. On the basis of these results, a second, more advanced, prototype was developed and utilized in limited field trials with the intention of moving the technology toward in situ applications.

  3. Determination of fuel assembly vibrational modes through analysis of incore detector noise

    International Nuclear Information System (INIS)

    Johnson, R.S.

    1986-01-01

    In order to better characterize fuel assembly vibration at Duke Power Company's Oconee Nuclear Station, incore noise data were acquired an analyzed from prompt responding detectors incorporated in the Oconee 2, Cycle 7 core. Duke Power Company began actively pursuing an inhouse Neutron Noise Analysis program for routine surveillance of reactor internals vibration in 1979. Noise data has since been acquired and analyzed for twelve cycles of operation for the three Oconee units. Duke Power's Oconee Unit 2 is a Babcock and Wilcoxs pressurized water reactor with a rate thermal power of 2568MW. For Oconee 2, Cycle 7 operation, two test assemblies, each employing a string of seven axially-spaced, prompt responding hafnium detectors, were included in the final core design. Incore detector noise data were obtained during Cycle 7 at approximately 281 and 430 effective full power days (EFPD). In addition to the incore test detector signals, noise signals from the upper and lower chambers of the four excore power range detectors were recorded to aid in the analysis. The comparison of RMS signal levels for each incore detector and the phase relationships between detector locations within two test assemblies identified the first four fuel assembly bending modes associated with fixed end conditions

  4. Boundary layer noise subtraction in hydrodynamic tunnel using robust principal component analysis.

    Science.gov (United States)

    Amailland, Sylvain; Thomas, Jean-Hugh; Pézerat, Charles; Boucheron, Romuald

    2018-04-01

    The acoustic study of propellers in a hydrodynamic tunnel is of paramount importance during the design process, but can involve significant difficulties due to the boundary layer noise (BLN). Indeed, advanced denoising methods are needed to recover the acoustic signal in case of poor signal-to-noise ratio. The technique proposed in this paper is based on the decomposition of the wall-pressure cross-spectral matrix (CSM) by taking advantage of both the low-rank property of the acoustic CSM and the sparse property of the BLN CSM. Thus, the algorithm belongs to the class of robust principal component analysis (RPCA), which derives from the widely used principal component analysis. If the BLN is spatially decorrelated, the proposed RPCA algorithm can blindly recover the acoustical signals even for negative signal-to-noise ratio. Unfortunately, in a realistic case, acoustic signals recorded in a hydrodynamic tunnel show that the noise may be partially correlated. A prewhitening strategy is then considered in order to take into account the spatially coherent background noise. Numerical simulations and experimental results show an improvement in terms of BLN reduction in the large hydrodynamic tunnel. The effectiveness of the denoising method is also investigated in the context of acoustic source localization.

  5. A full-spectrum analysis of high-speed train interior noise under multi-physical-field coupling excitations

    Science.gov (United States)

    Zheng, Xu; Hao, Zhiyong; Wang, Xu; Mao, Jie

    2016-06-01

    High-speed-railway-train interior noise at low, medium, and high frequencies could be simulated by finite element analysis (FEA) or boundary element analysis (BEA), hybrid finite element analysis-statistical energy analysis (FEA-SEA) and statistical energy analysis (SEA), respectively. First, a new method named statistical acoustic energy flow (SAEF) is proposed, which can be applied to the full-spectrum HST interior noise simulation (including low, medium, and high frequencies) with only one model. In an SAEF model, the corresponding multi-physical-field coupling excitations are firstly fully considered and coupled to excite the interior noise. The interior noise attenuated by sound insulation panels of carriage is simulated through modeling the inflow acoustic energy from the exterior excitations into the interior acoustic cavities. Rigid multi-body dynamics, fast multi-pole BEA, and large-eddy simulation with indirect boundary element analysis are first employed to extract the multi-physical-field excitations, which include the wheel-rail interaction forces/secondary suspension forces, the wheel-rail rolling noise, and aerodynamic noise, respectively. All the peak values and their frequency bands of the simulated acoustic excitations are validated with those from the noise source identification test. Besides, the measured equipment noise inside equipment compartment is used as one of the excitation sources which contribute to the interior noise. Second, a full-trimmed FE carriage model is firstly constructed, and the simulated modal shapes and frequencies agree well with the measured ones, which has validated the global FE carriage model as well as the local FE models of the aluminum alloy-trim composite panel. Thus, the sound transmission loss model of any composite panel has indirectly been validated. Finally, the SAEF model of the carriage is constructed based on the accurate FE model and stimulated by the multi-physical-field excitations. The results show

  6. Noise resistance applied to the study paints; Aplicacion de la tecnica de ruido electroquimico al estudio de pinturas comerciales de efecto barrera

    Energy Technology Data Exchange (ETDEWEB)

    Lanchas Garcia-Zarco, S.; Alfosin Perez, V.; Suarez Garcia, A.; Urrejola Madrinan, S.; Sanchez Bermudez, A.

    2015-03-30

    Electrochemical noise is one of the methods of analysis used to interpret the phenomenon of corrosion. It has a number of advantages over other methodology types including its simplicity, its low cost and the fact that it does not disturb the system. This methodology appears to be effective together with other techniques in metal-electrolyte systems. In this case the technique is applied on its own on commercial anti-corrosion paints for which no information is available from other techniques. The main result of this study reveals the effectiveness of the noise resistance parameter, which had already been tested in the lab, when it is used to explain how the paint system behaves in industry. (Author)

  7. Timing Noise Analysis of NANOGrav Pulsars

    OpenAIRE

    Perrodin, Delphine; Jenet, Fredrick; Lommen, Andrea; Finn, Lee; Demorest, Paul; Ferdman, Robert; Gonzalez, Marjorie; Nice, David; Ransom, Scott; Stairs, Ingrid

    2013-01-01

    We analyze timing noise from five years of Arecibo and Green Bank observations of the seventeen millisecond pulsars of the North-American Nanohertz Observatory for Gravitational Waves (NANOGrav) pulsar timing array. The weighted autocovariance of the timing residuals was computed for each pulsar and compared against two possible models for the underlying noise process. The first model includes red noise and predicts the autocovariance to be a decaying exponential as a function of time lag. Th...

  8. Data acquisition and processing system for reactor noise analysis

    International Nuclear Information System (INIS)

    Costa Oliveira, J.; Morais Da Veiga, C.; Forjaz Trigueiros, D.; Pombo Duarte, J.

    1975-01-01

    A data acquisition and processing system for reactor noise analysis by time correlation methods is described, consisting in one to four data feeding channels (transducer, associated electronics and V/f converter), a sampling unit, a landline transmission system and a PDP 15 computer. This system is being applied to study the kinetic parameters of the 'Reactor Portugues de Investigacao', a swimming-pool 1MW reactor. The main features that make such a data acquisition and processing system a useful tool to perform noise analysis are: the improved characteristics of analog-to-digital converters employed to quantize the signals; the use of an on-line computer which allows a great accumulation and a rapid treatment of data together with an easy check of the correctness of the experiments; and the adoption of the time cross-correlation technique using two-detectors which by-pass the limitation of low efficiency detectors. (author)

  9. Noise Parameter Analysis of SiGe HBTs for Different Sizes in the Breakdown Region

    Directory of Open Access Journals (Sweden)

    Chie-In Lee

    2016-01-01

    Full Text Available Noise parameters of silicon germanium (SiGe heterojunction bipolar transistors (HBTs for different sizes are investigated in the breakdown region for the first time. When the emitter length of SiGe HBTs shortens, minimum noise figure at breakdown decreases. In addition, narrower emitter width also decreases noise figure of SiGe HBTs in the avalanche region. Reduction of noise performance for smaller emitter length and width of SiGe HBTs at breakdown resulted from the lower noise spectral density resulting from the breakdown mechanism. Good agreement between experimental and simulated noise performance at breakdown is achieved for different sized SiGe HBTs. The presented analysis can benefit the RF circuits operating in the breakdown region.

  10. Analysis of community response to transportation noise a quarter century after Schultz (1978)

    Science.gov (United States)

    Fidell, Sanford

    2003-10-01

    Transportation noise is a vexing and intrinsically controversial problem that has plagued societies since the beginnings of urban civilization. A function relating cumulative noise exposure to the prevalence of noise-induced annoyance [T. J. Schultz, ``Synthesis of social surveys on noise annoyance,'' J. Acoust. Soc. Am. 64, 377-405 (1978)] is the foundation for contemporary analyses of transportation noise effects on communities. The expenditures of billions of dollars in airplane ticket and fuel taxes for the construction of an airport infrastructure and for the mitigation of noise impacts in the United States are governed by policies ostensibly supported by a successor to Schultz's original ``synthesis'' curve. Many have grown so comfortable with the last quarter century's paradigm for transportation noise assessment and regulation, however, that they have lost sight of its underpinnings and limitations. A review of the historical and modern states of the art identifies persistent unresolved problems in the prediction and explanation of community response to transportation noise that are not fully addressed by descriptive dosage-effect analysis.

  11. The importance of stimulus noise analysis for self-motion studies.

    Directory of Open Access Journals (Sweden)

    Alessandro Nesti

    Full Text Available Motion simulators are widely employed in basic and applied research to study the neural mechanisms of perception and action during inertial stimulation. In these studies, uncontrolled simulator-introduced noise inevitably leads to a disparity between the reproduced motion and the trajectories meticulously designed by the experimenter, possibly resulting in undesired motion cues to the investigated system. Understanding actual simulator responses to different motion commands is therefore a crucial yet often underestimated step towards the interpretation of experimental results. In this work, we developed analysis methods based on signal processing techniques to quantify the noise in the actual motion, and its deterministic and stochastic components. Our methods allow comparisons between commanded and actual motion as well as between different actual motion profiles. A specific practical example from one of our studies is used to illustrate the methodologies and their relevance, but this does not detract from its general applicability. Analyses of the simulator's inertial recordings show direction-dependent noise and nonlinearity related to the command amplitude. The Signal-to-Noise Ratio is one order of magnitude higher for the larger motion amplitudes we tested, compared to the smaller motion amplitudes. Simulator-introduced noise is found to be primarily of deterministic nature, particularly for the stronger motion intensities. The effect of simulator noise on quantification of animal/human motion sensitivity is discussed. We conclude that accurate recording and characterization of executed simulator motion are a crucial prerequisite for the investigation of uncertainty in self-motion perception.

  12. Relation between nonlinear or 'not-linear' characteristics in nuclear kinetics and noise analysis of neutron flux

    International Nuclear Information System (INIS)

    Kataoka, H.

    1975-01-01

    The 'not-linear' or '2nd-class-nonlinear' characteristics in nuclear reactor kinetics with the feedback effect in the high-power operation and induce the increase in the amplitude of the neutron flux noise, specially in the very low frequency region. The fundamental behaviour of 'not-linear' characteristics and its effect for the reactor noise was investigated. Application of the reactor noise analysis technique to power reactors has not been successful because of unknown large disagreement between the result of the conventional theoretical analysis and the experimental facts. When the cause of this discrepancy is clear, reactor noise analysis techniques can be effectively applied to instrumentation, control, monitoring and diagnosis of power reactors. (author)

  13. 32 CFR 989.32 - Noise.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Noise. 989.32 Section 989.32 National Defense... ANALYSIS PROCESS (EIAP) § 989.32 Noise. Aircraft noise data files used for analysis during EIAP will be... System for Aircraft Noise for military training routes and military operating areas. Guidance on...

  14. Electrochemical Determination of Chlorpyrifos on a Nano-TiO₂Cellulose Acetate Composite Modified Glassy Carbon Electrode.

    Science.gov (United States)

    Kumaravel, Ammasai; Chandrasekaran, Maruthai

    2015-07-15

    A rapid and simple method of determination of chlorpyrifos is important in environmental monitoring and quality control. Electrochemical methods for the determination of pesticides are fast, sensitive, reproducible, and cost-effective. The key factor in electrochemical methods is the choice of suitable electrode materials. The electrode materials should have good stability, reproducibility, more sensitivity, and easy method of preparation. Mercury-based electrodes have been widely used for the determination of chlorpyrifos. From an environmental point of view mercury cannot be used. In this study a biocompatible nano-TiO2/cellulose acetate modified glassy carbon electrode was prepared by a simple method and used for the electrochemical sensing of chlorpyrifos in aqueous methanolic solution. Electroanalytical techniques such as cyclic voltammetry, differential pulse voltammetry, and amperometry were used in this work. This electrode showed very good stability, reproducibility, and sensitivity. A well-defined peak was obtained for the reduction of chlorpyrifos in cyclic voltammetry and differential pulse voltammetry. A smooth noise-free current response was obtained in amperometric analysis. The peak current obtained was proportional to the concentration of chlorpyrifos and was used to determine the unknown concentration of chlorpyrifos in the samples. Analytical parameters such as LOD, LOQ, and linear range were estimated. Analysis of real samples was also carried out. The results were validated through HPLC. This composite electrode can be used as an alternative to mercury electrodes reported in the literature.

  15. Noise suppression and crosstalk analysis of on-chip magnetic film-type noise suppressor

    Science.gov (United States)

    Ma, Jingyan; Muroga, Sho; Endo, Yasushi; Hashi, Shuichiro; Naoe, Masayuki; Yokoyama, Hiroo; Hayashi, Yoshiaki; Ishiyama, Kazushi

    2018-05-01

    This paper discusses near field, conduction and crosstalk noise suppression of magnetic films with uniaxial anisotropy on transmission lines for a film-type noise suppressor in the GHz frequency range. The electromagnetic noise suppressions of magnetic films with different permeability and resistivity were measured and simulated with simple microstrip lines. The experimental and simulated results of Co-Zr-Nb and CoPd-CaF2 films agreed with each other. The results indicate that the higher permeability leads to a better near field shielding, and in the frequency range of 2-7 GHz, a higher conduction noise suppression. It also suggests that the higher resistivity results in a better crosstalk suppression in the frequency range below 2 GHz. These results can support the design guidelines of the magnetic film-type noise suppressor used in the next generation IC chip.

  16. Comparison of occupational noise legislation in the Americas: An overview and analysis

    Directory of Open Access Journals (Sweden)

    Jorge P Arenas

    2014-01-01

    Full Text Available The workplace contributes significantly to the total dose of daily noise to which a person is subjected. Therefore, millions of people around the world are exposed to potentially dangerous noise levels and consequently, there is an urgent, global need for legislation to adequately protect the auditory health of workers. Occupational noise legislation has been adopted in many of the countries with different degrees of comprehensiveness and varying levels of sophistication. This paper presents a global view of current legislation on occupational noise in the 22 countries that make up the Americas, that is, Latin America, Canada, and the United States. Upon analysis of the legislation, there are notable differences among countries in the defined values for permissible exposure limit (PEL and exchange rate. Of the countries that have regulations, the majority (81% use a PEL of 85 dBA. A PEL of 85 dBA and the 3-dB exchange rate are currently used by 32% of the nations in the Americas. Most nations limit impulsive noise exposure to a peak unweighted sound pressure level of 140 dB (or dBC, while a few use slightly lower limits. However, 27% of the countries in the region still have not established regulations with respect to permissible noise levels and exchange rates. This fact is leaving millions of workers in the Americas unprotected against occupational noise. Provide an overview and analysis of the current legislation on occupational noise in the 22 countries that make up the Americas. The information on legislation, regulations, and standards discussed in this paper were obtained directly from official government sources in each country, the International Labour Organization database, or through various colleagues in each country. (1 There are notable differences among countries in the defined values for PEL and exchange rate. (2 Of the countries that have regulations, the majority (81% use a PEL of 85 dBA. A PEL of 85 dBA and the 3-dB exchange

  17. Technical noise supplement : TeNS : a technical supplement to the Traffic Noise Analysis Protocol.

    Science.gov (United States)

    1998-10-01

    The purpose of this Technical Noise Supplement (TeNS) is to provide technical background : information on transportation-related noise in general and highway traffic noise in : particular. It is designed to elaborate on technical concepts and procedu...

  18. Structure and electrochemical properties of copper wires with seamless 1D nanostructures

    Directory of Open Access Journals (Sweden)

    Yutong Wu

    2018-04-01

    Full Text Available A seamless Cu nanowire array grown on Cu wire is prepared by combining thermal oxidation method and electrochemical reduction. The data set described in this paper includes the structure of the Cu nanowires electrode, electrocatalytic active surface area, linear sweep voltammetry and amperometry measurement for nitrate sensing. The electrochemical data show that Cu nanowire arrays exhibited a linear response to nitrate ions over a concentration range from 50 μM to 600 μM (R2 = 0.9974 with a sensitivity of 0.357 μA μM−1 cm−1 and detection limit of 12.2 μM at a signal-to-noise ratio of 3, respectively.

  19. PC analysis of stochastic differential equations driven by Wiener noise

    KAUST Repository

    Le Maitre, Olivier; Knio, Omar

    2015-01-01

    A polynomial chaos (PC) analysis with stochastic expansion coefficients is proposed for stochastic differential equations driven by additive or multiplicative Wiener noise. It is shown that for this setting, a Galerkin formalism naturally leads

  20. Active3 noise reduction

    International Nuclear Information System (INIS)

    Holzfuss, J.

    1996-01-01

    Noise reduction is a problem being encountered in a variety of applications, such as environmental noise cancellation, signal recovery and separation. Passive noise reduction is done with the help of absorbers. Active noise reduction includes the transmission of phase inverted signals for the cancellation. This paper is about a threefold active approach to noise reduction. It includes the separation of a combined source, which consists of both a noise and a signal part. With the help of interaction with the source by scanning it and recording its response, modeling as a nonlinear dynamical system is achieved. The analysis includes phase space analysis and global radial basis functions as tools for the prediction used in a subsequent cancellation procedure. Examples are given which include noise reduction of speech. copyright 1996 American Institute of Physics

  1. NoiseMap and AEDT Gap Analysis

    Science.gov (United States)

    2017-09-30

    NoiseMap and the Aviation Environmental Design Tool (AEDT) both use an integrated modeling approach to calculate aircraft noise in and around an airfield. Both models also employ the same general overall approach by using airfield operational data, s...

  2. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems

    International Nuclear Information System (INIS)

    Bouwman, R; Broeders, M; Van Engen, R; Young, K; Lazzari, B; Ravaglia, V

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does not discriminate sufficiently between systems with and without additional noise besides quantum noise. This paper attempts to give an alternative and relatively simple method for noise analysis which can divide noise into electronic noise, structured noise and quantum noise. Quantum noise needs to be the dominant noise source in clinical images for optimal performance of a digital mammography system, and therefore the amount of electronic and structured noise should be minimal. For several digital mammography systems, the noise was separated into components based on the measured pixel value, standard deviation (SD) of the image and the detector entrance dose. The results showed that differences between systems exist. Our findings confirm that the proposed method is able to discriminate systems based on their noise performance and is able to detect possible quality problems. Therefore, we suggest to replace the current method for noise analysis as described in the European Guidelines by the alternative method described in this paper.

  3. Electrochemical Characterization and Degradation Analysis of Large SOFC Stacks by Impedance Spectroscopy

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Hjelm, Johan; Barfod, R.

    2013-01-01

    As solid oxide fuel cell (SOFC) technology is moving closer to a commercial break through, lifetime limiting factors, and methods to measure the “state-of-health” of operating cells and stacks are becoming of increasing interest. This requires application of advanced methods for detailed...... electrochemical characterization during operation. An experimental stack with low ohmic resistance from Topsoe Fuel Cell A/S was characterized in detail using electrochemical impedance spectroscopy (EIS). An investigation of the optimal geometrical placement of the current feeds and voltage probes was carried out...... with hydrogen as fuel with 52% fuel utilization and constant current load (0.2 A cm–2) at 750 °C. Stack interconnects were coated with six different coatings to prevent chromium poisoning on the cathode side. Four repeating units (RUs) with different coatings were selected for detailed impedance analysis. EIS...

  4. Electrochemical degradation of the chloramphenicol at flow reactor

    International Nuclear Information System (INIS)

    Rezende, Luis Gustavo P.; Prado, Vania M. do; Rocha, Robson S.; Beati, Andre A.G.F.; Sotomayor, Maria del Pilar T.; Lanza, Marcos R.V.

    2010-01-01

    This paper reports a study of electrochemical degradation of the chloramphenicol antibiotic in aqueous medium using a flow-by reactor with DSA anode. The process efficiency was monitored by chloramphenicol concentration analysis with liquid chromatography (HPLC) during the experiments. Analysis of Total Organic Carbon (TOC) was performed to estimate the degradation degree and Ion Chromatography (IC) was performed to determinate inorganic ions formed during the electrochemical degradation process. In electrochemical flow-by reactor, 52% of chloramphenicol was degraded, with 12% TOC reduction. IC analysis showed the production of chloride ions (25 mg L -1 ), nitrate ions (6 mg L -1 ) and nitrite ions (4.5 mg L -1 ). (author)

  5. CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review

    Directory of Open Access Journals (Sweden)

    Haitao Li

    2016-12-01

    Full Text Available Modern biosensors play a critical role in healthcare and have a quickly growing commercial market. Compared to traditional optical-based sensing, electrochemical biosensors are attractive due to superior performance in response time, cost, complexity and potential for miniaturization. To address the shortcomings of traditional benchtop electrochemical instruments, in recent years, many complementary metal oxide semiconductor (CMOS instrumentation circuits have been reported for electrochemical biosensors. This paper provides a review and analysis of CMOS electrochemical instrumentation circuits. First, important concepts in electrochemical sensing are presented from an instrumentation point of view. Then, electrochemical instrumentation circuits are organized into functional classes, and reported CMOS circuits are reviewed and analyzed to illuminate design options and performance tradeoffs. Finally, recent trends and challenges toward on-CMOS sensor integration that could enable highly miniaturized electrochemical biosensor microsystems are discussed. The information in the paper can guide next generation electrochemical sensor design.

  6. Identifying functions for ex-core neutron noise analysis

    International Nuclear Information System (INIS)

    Avila, J.M.; Oliveira, J.C.

    1987-01-01

    A method of performing the phase analysis of signals arising from neutron detectors placed in the periphery of a pressurized water reactor is proposed. It consists in the definition of several identifying functions, based on the phases of cross power spectral densities corresponding to four ex-core neutron detectors. Each of these functions enhances the appearance of different sources of noise. The method, applied to the ex-core neutron fluctuation analysis of a French PWR, proved to be very useful as it allows quick recognition of various patterns in the power spectral densities. (orig.) [de

  7. In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating

    Directory of Open Access Journals (Sweden)

    Nicolas A. Alba

    2015-10-01

    Full Text Available Neural electrodes hold tremendous potential for improving understanding of brain function and restoring lost neurological functions. Multi-walled carbon nanotube (MWCNT and dexamethasone (Dex-doped poly(3,4-ethylenedioxythiophene (PEDOT coatings have shown promise to improve chronic neural electrode performance. Here, we employ electrochemical techniques to characterize the coating in vivo. Coated and uncoated electrode arrays were implanted into rat visual cortex and subjected to daily cyclic voltammetry (CV and electrochemical impedance spectroscopy (EIS for 11 days. Coated electrodes experienced a significant decrease in 1 kHz impedance within the first two days of implantation followed by an increase between days 4 and 7. Equivalent circuit analysis showed that the impedance increase is the result of surface capacitance reduction, likely due to protein and cellular processes encapsulating the porous coating. Coating’s charge storage capacity remained consistently higher than uncoated electrodes, demonstrating its in vivo electrochemical stability. To decouple the PEDOT/MWCNT material property changes from the tissue response, in vitro characterization was conducted by soaking the coated electrodes in PBS for 11 days. Some coated electrodes exhibited steady impedance while others exhibiting large increases associated with large decreases in charge storage capacity suggesting delamination in PBS. This was not observed in vivo, as scanning electron microscopy of explants verified the integrity of the coating with no sign of delamination or cracking. Despite the impedance increase, coated electrodes successfully recorded neural activity throughout the implantation period.

  8. Analysis of noise on construction sites of high-rise buildings.

    Science.gov (United States)

    Barkokébas, Béda; Vasconcelos, Bianca M; Lago, Eliane Maria G; Alcoforador, Aline Fabiana P

    2012-01-01

    In the civil construction industry sector, it has been observed that the increasing use of machines has made tasks noisier and consequently caused hearing loss and had other adverse effects on workers. The objective of this study was to identify and assess the physical risks of noise present in activities undertaken in a construction company in order to propose control measures which will contribute to the management of health and safety within the company's organization. The methodology applied was based on verifying the characteristics of exposure to noise on construction sites, from an observation of sources which generated noise and making measurements of sound pressure levels emitted by these sources. The data was then analyzed and compared with the recommended performance levels established in control measures. As a result, it was found that some machines and equipment used in civil construction often generate noise above the acceptable levels and as such, in these cases, various control measures have been proposed. It is believed that the use of management techniques is the most effective way to assess risk and to implement the preventive and corrective actions proposed, and allows for the analysis of sound pressure levels on an ongoing basis.

  9. Noise Pollution: Do We Need a Solution? An Analysis of Noise in a Cardiac Care Unit.

    Science.gov (United States)

    Ryan, Kevin M; Gagnon, Matthew; Hanna, Tyler; Mello, Brad; Fofana, Mustapha; Ciottone, Gregory; Molloy, Michael

    2016-08-01

    49.24% of alarms. The CCU cares for ill patients requiring constant monitoring. Despite advances in technology, measured noise levels for the hospital studied exceeded WHO standards of 40 dB and peaks of 45 dB, even during night hours when patients require rest. Further work is required to reduce noise levels and examine effects on patient satisfaction, clinical outcomes, and length of stay. Ryan KM , Gagnon M , Hanna T , Mello B , Fofana M , Ciottone G , Molloy M . Noise pollution: do we need a solution? An analysis of noise in a cardiac care unit. Prehosp Disaster Med. 2016;31(4):432-435.

  10. The Traffic Noise Index: A Method of Controlling Noise Nuisance.

    Science.gov (United States)

    Langdon, F. J.; Scholes, W. E.

    This building research survey is an analysis of the social nuisance caused by urban motor ways and their noise. The Traffic Noise Index is used to indicate traffic noises and their effects on architectural designs and planning, while suggesting the need for more and better window insulation and acoustical barriers. Overall concern is for--(1)…

  11. TRANSITIONS IN ELECTROCHEMICAL NOISE DURING PITTING CORROSION OF ALUMINUM IN CHLORIDE ENVIRONMENTS

    International Nuclear Information System (INIS)

    SASAKI, K.; ISAACS, H.S.; LEVY, P.W.

    2001-01-01

    Aluminum, in a chloride containing solutions close to its pitting potential, shows vigorous fluctuations in current and potential. Measurements have been made of the freely corroding potential, and the currents between interconnected electrodes. It is shown that there is a transition in the behavior of the transients. The transition occurs when multiple active pits are present and electrochemical communication occurs between them. The major source of current and potential transients is the growth process in the active pits rather than meta-stable pitting at the passive surface

  12. TRANSITIONS IN ELECTROCHEMICAL NOISE DURING PITTING CORROSION OF ALUMINUM IN CHLORIDE ENVIRONMENTS.

    Energy Technology Data Exchange (ETDEWEB)

    SASAKI,K.; ISAACS,H.S.; LEVY,P.W.

    2001-09-02

    Aluminum, in a chloride containing solutions close to its pitting potential, shows vigorous fluctuations in current and potential. Measurements have been made of the freely corroding potential, and the currents between interconnected electrodes. It is shown that there is a transition in the behavior of the transients. The transition occurs when multiple active pits are present and electrochemical communication occurs between them. The major source of current and potential transients is the growth process in the active pits rather than meta-stable pitting at the passive surface.

  13. Graphene Ink Film Based Electrochemical Detector for Paracetamol Analysis

    Directory of Open Access Journals (Sweden)

    Li Fu

    2018-01-01

    Full Text Available Graphene ink is a commercialized product in the graphene industry with promising potential application in electronic device design. However, the limitation of the graphene ink is its low electronic performance due to the ink preparation protocol. In this work, we proposed a simple post-treatment of graphene ink coating via electrochemical oxidation. The electronic conductivity of the graphene ink coating was enhanced as expected after the treatment. The proposed electrochemical oxidation treatment also exposes the defects of graphene and triggered an electrocatalytic reaction during the sensing of paracetamol (PA. The overpotential of redox is much lower than conventional PA redox potential, which is favorable for avoiding the interference species. Under optimum conditions, the graphene ink-based electrochemical sensor could linearly detect PA from 10 to 500 micro molar (μM, with a limit of detection of 2.7 μM.

  14. Analysis of impact noise induced by hitting of titanium head golf driver.

    Science.gov (United States)

    Kim, Young Ho; Kim, Young Chul; Lee, Jun Hee; An, Yong-Hwi; Park, Kyung Tae; Kang, Kyung Min; Kang, Yeon June

    2014-11-01

    The hitting of titanium head golf driver against golf ball creates a short duration, high frequency impact noise. We analyzed the spectra of these impact noises and evaluated the auditory hazards from exposure to the noises. Noises made by 10 titanium head golf drivers with five maximum hits were collected, and the spectra of the pure impact sounds were studied using a noise analysis program. The noise was measured at 1.7 m (position A) and 3.4 m (position B) from the hitting point in front of the hitter and at 3.4 m (position C) behind the hitting point. Average time duration was measured and auditory risk units (ARUs) at position A were calculated using the Auditory Hazard Assessment Algorithm for Humans. The average peak levels at position A were 119.9 dBA at the sound pressure level (SPL) peak and 100.0 dBA at the overall octave level. The average peak levels (SPL and overall octave level) at position B were 111.6 and 96.5 dBA, respectively, and at position C were 111.5 and 96.7 dBA, respectively. The average time duration and ARUs measured at position A were 120.6 ms and 194.9 units, respectively. Although impact noises made by titanium head golf drivers showed relatively low ARUs, individuals enjoying golf frequently may be susceptible to hearing loss due to the repeated exposure of this intense impact noise with short duration and high frequency. Unprotected exposure to impact noises should be limited to prevent cochleovestibular disorders.

  15. Bedload transport from spectral analysis of seismic noise near rivers

    Science.gov (United States)

    Hsu, L.; Finnegan, N. J.; Brodsky, E. E.

    2010-12-01

    Channel change in rivers is driven by bedload sediment transport. However, the nonlinear nature of sediment transport combined with the difficulty of making direct observations in rivers at flood hinder prediction of the timing and magnitude of bedload movement. Recent studies have shown that spectral analysis of seismic noise from seismometers near rivers illustrate a correlation between the relative amplitude of high frequency (>1 Hz) seismic noise and conditions for bedload transport, presumably from the energy transferred from clast collisions with the channel. However, a previous study in the Himalayas did not contain extensive bedload transport or discharge measurements, and the correspondence of seismic noise with proxy variables such as regional hydrologic and meteorologic data was not exact. A more complete understanding of the relationship between bedload transport and seismic noise would be valuable for extending the spatial and temporal extent of bedload data. To explore the direct relationship between bedload transport and seismic noise, we examine data from several seismic stations near the Trinity River in California, where the fluvial morphodynamics and bedload rating curves have been studied extensively. We compare the relative amplitude of the ambient seismic noise with records of water discharge and sediment transport. We also examine the noise at hourly, daily, and seasonal timescales to determine other possible sources of noise. We report the influence of variables such as local river slope, adjacent geology, anthropogenic noise, and distance from the river. The results illustrate the feasibility of using existing seismic arrays to sense radiated energy from processes of bedload transport. In addition, the results can be used to design future seismic array campaigns to optimize information about bedload transport. This technique provides great spatial and temporal coverage, and can be performed where direct bedload measurements are difficult or

  16. Theoretical analysis of quantum dot amplifiers with high saturation power and low noise figure

    DEFF Research Database (Denmark)

    Berg, Tommy Winther; Mørk, Jesper

    2002-01-01

    Semiconductor quantum dot amplifiers are predicted to exhibit superior characteristics such as high gain, and output power and low noise. The analysis provides criteria and design guidelines for the realization of high quality amplifiers.......Semiconductor quantum dot amplifiers are predicted to exhibit superior characteristics such as high gain, and output power and low noise. The analysis provides criteria and design guidelines for the realization of high quality amplifiers....

  17. Noise removal using factor analysis of dynamic structures: application to cardiac gated studies.

    Science.gov (United States)

    Bruyant, P P; Sau, J; Mallet, J J

    1999-10-01

    Factor analysis of dynamic structures (FADS) facilitates the extraction of relevant data, usually with physiologic meaning, from a dynamic set of images. The result of this process is a set of factor images and curves plus some residual activity. The set of factor images and curves can be used to retrieve the original data with reduced noise using an inverse factor analysis process (iFADS). This improvement in image quality is expected because the inverse process does not use the residual activity, assumed to be made of noise. The goal of this work is to quantitate and assess the efficiency of this method on gated cardiac images. A computer simulation of a planar cardiac gated study was performed. The simulated images were added with noise and processed by the FADS-iFADS program. The signal-to-noise ratios (SNRs) were compared between original and processed data. Planar gated cardiac studies from 10 patients were tested. The data processed by FADS-iFADS were subtracted to the original data. The result of the substraction was studied to evaluate its noisy nature. The SNR is about five times greater after the FADS-iFADS process. The difference between original and processed data is noise only, i.e., processed data equals original data minus some white noise. The FADS-iFADS process is successful in the removal of an important part of the noise and therefore is a tool to improve the image quality of cardiac images. This tool does not decrease the spatial resolution (compared with smoothing filters) and does not lose details (compared with frequential filters). Once the number of factors is chosen, this method is not operator dependent.

  18. Fast noise level estimation algorithm based on principal component analysis transform and nonlinear rectification

    Science.gov (United States)

    Xu, Shaoping; Zeng, Xiaoxia; Jiang, Yinnan; Tang, Yiling

    2018-01-01

    We proposed a noniterative principal component analysis (PCA)-based noise level estimation (NLE) algorithm that addresses the problem of estimating the noise level with a two-step scheme. First, we randomly extracted a number of raw patches from a given noisy image and took the smallest eigenvalue of the covariance matrix of the raw patches as the preliminary estimation of the noise level. Next, the final estimation was directly obtained with a nonlinear mapping (rectification) function that was trained on some representative noisy images corrupted with different known noise levels. Compared with the state-of-art NLE algorithms, the experiment results show that the proposed NLE algorithm can reliably infer the noise level and has robust performance over a wide range of image contents and noise levels, showing a good compromise between speed and accuracy in general.

  19. Intensity of noise in the classroom and analysis of acoustic emissions in schoolchildren

    Directory of Open Access Journals (Sweden)

    Almeida Filho, Nelson de

    2012-01-01

    Full Text Available Introduction: Noise-induced hearing loss is a sensorineural hearing loss, usually bilateral, irreversible and progressive with time of exposure. As the noise made by children in school may be considered detrimental, the study looks of their occurrence in Taubaté's schools. Objective: To determine if students are exposed to noise intensity affecting the cochlea, define the profile of these schoolchildren, demonstrating the occurrence of changes in cochlear activity following exposure to noise in a day of class. Method: Study's way prospective transversal cross sectional cut with 28 elementary school students in the first half of 2009. Questionnaires for assessing preexisting cochlear damage . Evaluation of cochlear function by analysis of acoustic emissions evoked distortion product, made before the students come into class and immediately after the end of these. Measurement of noise inside the classrooms and recreation areas during the interval. Results: 57.1% accused some hearing loss in the examinations before class. By day's end, 04 girls and 03 boys had worsened in relation of the first examination. The noise reached levels higher than recommended at the three class rooms. The largest number of students with worsening, belong to the class room with higher noise level. The noise during the intervals is also excessive. Conclusions: The noise in this school is above the limit. 42.85% of students who had experienced worsening had school performance inadequate. 25% had worse after noise exposure in a school day.

  20. Road Traffic Noise Pollution Analysis for Cernavoda City

    Science.gov (United States)

    Manea, L.; Manea, A.; Florea, D.; Tarulescu, S.

    2017-10-01

    In the present paper was studied the noise pollution in Cernavodă city. The noise measurements were made for nine intersections from different city areas. Noise measurements were taken for three chosen routes with high population density, heavy traffic, commercial and residential buildings. Average, maximum and minimum values were collected and compared with standards. The impact of road traffic noise on the community depends on various factors such as road location and design, land use planning measures, building design, traffic composition, driver behaviour and the relief. In the study area 9 locations are identified to measure noise level. By using sound level meter noise levels are measured at different peak sessions i.e. morning, afternoon and evening. The presented values were collected for evening rush hour.

  1. Validation of the dynamics of SDS and RRS flux, flow, pressure and temperature signals using noise analysis technique

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Tulett, M.V.

    1995-01-01

    In 1992, a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro's CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. Critical plant components, instrumentation and processes are monitored on a regular basis, and their dynamic characteristics are verified on-power. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes, reactivity devices and fuel channels induced by moderator/coolant flow, (6) estimating the dynamics and response time of RTD temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (1 0) detecting coolant boiling in fully instrumented fuel channels, (1 1) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the

  2. On-Chip Evaluation of DNA Methylation with Electrochemical Combined Bisulfite Restriction Analysis Utilizing a Carbon Film Containing a Nanocrystalline Structure.

    Science.gov (United States)

    Kurita, Ryoji; Yanagisawa, Hiroyuki; Kamata, Tomoyuki; Kato, Dai; Niwa, Osamu

    2017-06-06

    This paper reports an on-chip electrochemical assessment of the DNA methylation status in genomic DNA on a conductive nanocarbon film electrode realized with combined bisulfite restriction analysis (COBRA). The film electrode consists of sp 2 and sp 3 hybrid bonds and is fabricated with an unbalanced magnetron (UBM) sputtering method. First, we studied the effect of the sp 2 /sp 3 ratio of the UBM nanocarbon film electrode with p-aminophenol, which is a major electro-active product of the labeling enzyme from p-aminophenol phosphate. The signal current for p-aminophenol increases as the sp 2 content in the UBM nanocarbon film electrode increases because of the π-π interaction between aromatic p-aminophenol and the graphene-like sp 2 structure. Furthermore, the capacitative current at the UBM nanocarbon film electrode was successfully reduced by about 1 order of magnitude thanks to the angstrom-level surface flatness. Therefore, a high signal-to-noise ratio was achieved compared with that of conventional electrodes. Then, after performing an ELISA-like hybridization assay with a restriction enzyme, we undertook an electrochemical evaluation of the cytosine methylation status in DNA by measuring the oxidation current derived from p-aminophenol. When the target cytosine in the analyte sequence is methylated (unmethylated), the restriction enzyme of HpyCH4IV is able (unable) to cleave the sequence, that is, the detection probe cannot (can) hybridize. We succeeded in estimating the methylation ratio at a site-specific CpG site from the peak current of a cyclic voltammogram obtained from a PCR product solution ranging from 0.01 to 1 nM.

  3. Electrochemical approach for acute myocardial infarction diagnosis based on direct antibodies-free analysis of human blood plasma.

    Science.gov (United States)

    Suprun, Elena V; Saveliev, Anatoly A; Evtugyn, Gennady A; Lisitsa, Alexander V; Bulko, Tatiana V; Shumyantseva, Victoria V; Archakov, Alexander I

    2012-03-15

    A novel direct antibodies-free electrochemical approach for acute myocardial infarction (AMI) diagnosis has been developed. For this purpose, a combination of the electrochemical assay of plasma samples with chemometrics was proposed. Screen printed carbon electrodes modified with didodecyldimethylammonium bromide were used for plasma charactrerization by cyclic (CV) and square wave voltammetry and square wave (SWV) voltammetry. It was shown that the cathodic peak in voltammograms at about -250 mV vs. Ag/AgCl can be associated with AMI. In parallel tests, cardiac myoglobin and troponin I, the AMI biomarkers, were determined in each sample by RAMP immunoassay. The applicability of the electrochemical testing for AMI diagnostics was confirmed by statistical methods: generalized linear model (GLM), linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA), artificial neural net (multi-layer perception, MLP), and support vector machine (SVM), all of which were created to obtain the "True-False" distribution prediction where "True" and "False" are, respectively, positive and negative decision about an illness event. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. A Comparison of seismic instrument noise coherence analysis techniques

    Science.gov (United States)

    Ringler, A.T.; Hutt, C.R.; Evans, J.R.; Sandoval, L.D.

    2011-01-01

    The self-noise of a seismic instrument is a fundamental characteristic used to evaluate the quality of the instrument. It is important to be able to measure this self-noise robustly, to understand how differences among test configurations affect the tests, and to understand how different processing techniques and isolation methods (from nonseismic sources) can contribute to differences in results. We compare two popular coherence methods used for calculating incoherent noise, which is widely used as an estimate of instrument self-noise (incoherent noise and self-noise are not strictly identical but in observatory practice are approximately equivalent; Holcomb, 1989; Sleeman et al., 2006). Beyond directly comparing these two coherence methods on similar models of seismometers, we compare how small changes in test conditions can contribute to incoherent-noise estimates. These conditions include timing errors, signal-to-noise ratio changes (ratios between background noise and instrument incoherent noise), relative sensor locations, misalignment errors, processing techniques, and different configurations of sensor types.

  5. The signal-to-noise analysis of the Little-Hopfield model revisited

    International Nuclear Information System (INIS)

    Bolle, D; Blanco, J Busquets; Verbeiren, T

    2004-01-01

    Using the generating functional analysis an exact recursion relation is derived for the time evolution of the effective local field of the fully connected Little-Hopfield model. It is shown that, by leaving out the feedback correlations arising from earlier times in this effective dynamics, one precisely finds the recursion relations usually employed in the signal-to-noise approach. The consequences of this approximation as well as the physics behind it are discussed. In particular, it is pointed out why it is hard to notice the effects, especially for model parameters corresponding to retrieval. Numerical simulations confirm these findings. The signal-to-noise analysis is then extended to include all correlations, making it a full theory for dynamics at the level of the generating functional analysis. The results are applied to the frequently employed extremely diluted (a)symmetric architectures and to sequence processing networks

  6. Development of electronic system for reactivity measurement and reactor noise analysis

    International Nuclear Information System (INIS)

    Strohl, Claude Emile; Soares, Adalberto Jose

    1996-01-01

    In nuclear power reactors, the neutron detector signal is dependent of the number of fissions and the reactor power level. The detector signal can be divided into two components; a DC component, proportional to the average value and an AC component, which is the fluctuating part superimposed to the DC component. The analysis of the fluctuating part of the signal is called noise analysis and allow us to investigate phenomena occurring within the reactor vessel, such as vibration of fuels elements and coolant density, temperature, pressure and flow changes. On the other hand, the measure of the static DC part allow us to measure the local power density. This paper describes the development of a personal computer based signal conditioning card that, together with a personal computer commercial data acquisition card, can be used for noise analysis measurements and reactivity measurements of signals coming from ionization chambers or SPD's. (author)

  7. Recent Advances in Electrochemical Glycobiosensing

    Directory of Open Access Journals (Sweden)

    Germarie Sánchez-Pomales

    2011-01-01

    Full Text Available Biosensors based on electrochemical transduction mechanisms have recently made advances into the field of glycan analysis. These glyco-biosensors offer simple, rapid, sensitive, and economical approaches to the measurement need for rapid glycan analysis for biomarker detection, cancer and disease diagnostics, and bioprocess monitoring of therapeutic glycoproteins. Although the prevalent methods of glycan analysis (high-performance liquid chromatography, mass spectrometry, and nuclear magnetic resonance spectroscopy provide detailed identification and structural analysis of glycan species, there are significantly few low-cost, rapid glycan assays available for diagnostic and screening applications. Here we review instances in which glyco-biosensors have been used for glycan analysis using a variety of electrochemical transduction mechanisms (e.g., amperometric, potentiometric, impedimetric, and voltammetric, selective binding agents (e.g., lectins and antibodies, and redox species (e.g., enzyme substrates, inorganic, and nanomaterial.

  8. Noise analysis of the measurement of group delay in Fourier white-light interferometric cross correlation

    International Nuclear Information System (INIS)

    Laude, Vincent

    2002-01-01

    The problem of noise analysis in measuring the group delay introduced by a dispersive optical element by use of white-light interferometric cross correlation is investigated. Two noise types, detection noise and position noise, are specifically analyzed. Detection noise is shown to be highly sensitive to the spectral content of the white-light source at the frequency considered and to the temporal acquisition window. Position noise, which arises from the finite accuracy of the measurement of the scanning mirror's position, can severely damage the estimation of the group delay. Such is shown to be the case for fast Fourier transform-based estimation algorithms. A new algorithm that is insensitive to scanning delay errors is proposed, and subfemtosecond accuracy is obtained without any postprocessing

  9. State of the art on reactor noise analysis

    International Nuclear Information System (INIS)

    Bernard, P.; Fry, D.; Stegemann, D.; Van Dam, H.

    1986-01-01

    This report is the result of the work of a task force sponsored by the NEA Committee on Reactor Physics (NEACRP) and is divided into six chapters: 1. Loose-Parts Detection and Acoustic Monitoring, 2. Thermal Hydraulics Surveillance, 3. Flow Measurements, 4. Vibration Monitoring, 5. Surveillance Systems and Evaluation Methods, and 6. System Dynamic Analysis. Each chapter summarizes the current situation in noise analysis techniques with emphasis on the following aspects: . physical quantities considered, . possible anomalies involved, . sensors used for the detection, and . conditions of applications. The remainder of each chapter discusses future trends and recommendations

  10. Possibilities to employ noise analysis techniques in controlling nuclear power stations

    International Nuclear Information System (INIS)

    Alfonso Pallares, C.; Iglesias Ferrer, R.; Sarabia Molina, I.

    1998-01-01

    This work shows basic requirements the authors think must be complied with by monitoring systems for operational surveillance based on noise analysis techniques that in turn can be employed in the regulatory control

  11. Applications of Nonlinear Electrochemical Impedance Spectroscopy (NLEIS)

    KAUST Repository

    Adler, S. B.

    2013-08-31

    This paper reviews the use of nonlinear electrochemical impedance spectroscopy (NLEIS) in the analysis of SOFC electrode reactions. By combining EIS and NLEIS, as well as other independent information about an electrode material, it becomes possible to establish quantitative links between electrochemical kinetics and materials properties, even when systems are unstable with time. After a brief review of the method, this paper summarizes recent results analyzing the effects of Sr segregation in thin-film LSC electrodes. © The Electrochemical Society.

  12. Experience with a PC-based system for noise and DC signal analysis in PWRs

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1996-01-01

    A data acquisition system that was originally developed for noise diagnostics in PWRs was expanded to include DC signal analysis in addition to noise analysis. The system has been used in PWRs for reactor diagnostics, determination of root cause of process anomalies, instrument calibration verification, measurement of drop time of control and shutdown rods, testing of timing and sequencing of control rod drive mechanisms, emergency diesel generator monitoring, etc. These applications are reviewed in this paper. (author)

  13. Complexity in White Noise Analysis

    Science.gov (United States)

    Hida, Takeyuki

    We restrict our attention to random complex systems and discuss degree their degree of complexity based on a white noise. The white noise is realized as the time derivative of a Brownian motion B(t), and denoted by Ḃ(t). The collection {Ḃ(t)}, is a system of idealized elementary variables and at the same time the system is a stochastic representation of the time t, in other words it is time-oriented. Having expressed the given evolutional random phenomena in question in terms of the Ḃ(t), we introduce the notion of spectral multiplicity, which describes how much the phenomena are complex. The multiplicity is the number of cyclic subspaces that are spanned by the given random phenomena. Each cyclic subspace has further structure. Typical property is multiple Markov property, although this property appears only particular cases. As a related property, in fact as a characteristic of a complex system, one can speak of the time reversibility and irreversibility of certain random phenomena in terms of the white noise. We expect an irreversible random complex system may be decomposed into reversible systems.

  14. Annual modulation of the galactic binary confusion noise background and LISA data analysis

    International Nuclear Information System (INIS)

    Seto, Naoki

    2004-01-01

    We study the anisotropies of the galactic confusion noise background and its effects on LISA data analysis. LISA has two data streams of gravitational wave signals relevant for the low frequency regime. Because of the anisotropies of the background, the matrix for their confusion noises has off-diagonal components and depends strongly on the orientation of the detector plane. We find that the sky-averaged confusion noise level √(S(f)) could change by a factor of 2 in 3 months and would be minimum when the orbital position of LISA is around either the spring or autumn equinox

  15. Analysis of noise emitted from diesel engines

    Science.gov (United States)

    Narayan, S.

    2015-12-01

    In this work combustion noise produced in diesel engines has been investigated. In order to reduce the exhaust emissions various injection parameters need to be studied and optimized. The noise has been investigated by mean of data obtained from cylinder pressure measurements using piezo electric transducers and microphones on a dual cylinder diesel engine test rig. The engine was run under various operating conditions varying various injection parameters to investigate the effects of noise emissions under various testing conditions.

  16. Adjusting phenotypes by noise control.

    Directory of Open Access Journals (Sweden)

    Kyung H Kim

    2012-01-01

    Full Text Available Genetically identical cells can show phenotypic variability. This is often caused by stochastic events that originate from randomness in biochemical processes involving in gene expression and other extrinsic cellular processes. From an engineering perspective, there have been efforts focused on theory and experiments to control noise levels by perturbing and replacing gene network components. However, systematic methods for noise control are lacking mainly due to the intractable mathematical structure of noise propagation through reaction networks. Here, we provide a numerical analysis method by quantifying the parametric sensitivity of noise characteristics at the level of the linear noise approximation. Our analysis is readily applicable to various types of noise control and to different types of system; for example, we can orthogonally control the mean and noise levels and can control system dynamics such as noisy oscillations. As an illustration we applied our method to HIV and yeast gene expression systems and metabolic networks. The oscillatory signal control was applied to p53 oscillations from DNA damage. Furthermore, we showed that the efficiency of orthogonal control can be enhanced by applying extrinsic noise and feedback. Our noise control analysis can be applied to any stochastic model belonging to continuous time Markovian systems such as biological and chemical reaction systems, and even computer and social networks. We anticipate the proposed analysis to be a useful tool for designing and controlling synthetic gene networks.

  17. Temperature noise analysis and sodium boiling detection in the fuel failure mockup

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Fry, D.N.; Leavell, W.H.; Mathis, M.V.; Saxe, R.F.

    1976-01-01

    Sodium temperature noise was measured at the exit of simulated, fast-reactor fuel subassemblies in the Fuel Failure Mockup (FFM) to determine the feasibility of using temperature noise monitors to detect flow blockages in fast reactors. Also, acoustic noise was measured to determine whether sodium boiling in the FFM could be detected acoustically and whether noncondensable gas entrained in the sodium coolant would affect the sensitivity of the acoustic noise detection system. Information from these studies would be applied to the design of safety systems for operating liquid-metal fast breeder reactors (LMFBRs). It was determined that the statistical properties of temperature noise are dependent on the shape of temperature profiles across the subassemblies, and that a blockage upstream of a thermocouple that increases the gradient of the profile near the blockage will also increase the temperature noise at the thermocouple. Amplitude probability analysis of temperature noise shows a skewed amplitude density function about the mean temperature that varies with the location of the thermocouple with respect to the blockage location. It was concluded that sodium boiling in the FFM could be detected acoustically. However, entrained noncondensable gas in the sodium coolant at void fractions greater than 0.4 percent attenuated the acoustic signals sufficiently that boiling was not detected. At a void fraction of 0.1 percent, boiling was indicated only by the two acoustic detectors closest to the boiling site

  18. Microstructure analysis for quantification of Barkhausen noise method and nondestructive evaluation of fracture characteristics

    International Nuclear Information System (INIS)

    Kim, Dong Won; Kwon, Dong Il

    1999-01-01

    Barkhausen noise method as a magnetic nondestructive test has the advantages for evaluating the properties of magnetic material more precisely and high-sensitively compared to other magnetic NDT methods. For a long time Barkhausen noise method was applied to measure the bulk magnetic properties of magnetic materials and recently to evaluate microstructure, stress analysis, fatigue, creep, and fracture characteristics as a NDT method. But so far Barkhausen noise method has been used as evaluating orientation of material properties rather qualitatively. For this reason, many NDT testing methods have seldom been applied to industrial plants and laboratories. In this study we make experiments on the variation of Barkhausen noise as microstructure, and quantify Barkhausen noise(rms voltage) via formula of velocity of magnetic domain walls using coercive force as retarding force of domain wall movement. As a result, we could evaluate the microstructure of magnetic materials and trends of fracture toughness quantitatively by measuring Barkhausen noise, therefore directly evaluate microstructure and fracture toughness by Barkhausen noise method as accurate in-situ nondestructive testing method.

  19. Analysis of noise in energy-dispersive spectrometers using time-domain methods

    CERN Document Server

    Goulding, F S

    2002-01-01

    This paper presents an integrated time domain approach to the optimization of the signal-to-noise ratio in all spectrometer systems that contain a detector that converts incoming quanta of radiation into electrical pulse signals that are amplified and shaped by an electronic pulse shaper. It allows analysis of normal passive pulse shapers as well as time-variant systems where switching of shaping elements occurs in synchronism with the signal. It also deals comfortably with microcalorimeters (sometimes referred to as bolometers), where noise-determining elements, such as the temperature-sensing element's resistance and temperature, change with time in the presence of a signal. As part of the purely time-domain approach, a new method of calculating the Johnson noise in resistors using only the statistics of electron motion is presented. The result is a time-domain analog of the Nyquist formula.

  20. The Security Analysis of Two-Step Quantum Direct Communication Protocol in Collective-Rotation Noise Channel

    International Nuclear Information System (INIS)

    Li Jian; Sun Feng-Qi; Pan Ze-Shi; Nie Jin-Rui; Chen Yan-Hua; Yuan Kai-Guo

    2015-01-01

    To analyze the security of two-step quantum direct communication protocol (QDCP) by using Einstein–Podolsky–Rosen pair proposed by Deng et al. [Phys. Rev. A 68 (2003) 042317] in collective-rotation noise channel, an excellent model of noise analysis is proposed. In the security analysis, the method of the entropy theory is introduced, and is compared with QDCP, an error rate point Q 0 (M : (Q 0 , 1.0)) is given. In different noise levels, if Eve wants to obtain the same amount of information, the error rate Q is distinguishable. The larger the noise level ϵ is, the larger the error rate Q is. When the noise level ϵ is lower than 11%, the high error rate is 0.153 without eavesdropping. Lastly, the security of the proposed protocol is discussed. It turns out that the quantum channel will be safe when Q < 0.153. Similarly, if error rate Q > 0.153 = Q 0 , eavesdropping information I > 1, which means that there exist eavesdroppers in the quantum channel, and the quantum channel will not be safe anymore. (paper)

  1. Modelling of passive films: complementarity and applicability to the electrochemical impedance spectroscopy analysis

    International Nuclear Information System (INIS)

    Boissy, Clement; Normand, Bernard

    2013-01-01

    A review of the published models to describe the passivation of metallic materials is proposed. The objective is to illustrate the importance of the selection of a model considering their complementarity. The discussion is based on an analysis to assess whether the mass transport in the film must be taken into account or not in the modelling of the electrochemical impedance. (authors)

  2. Method for analyzing electromagnetic-force-induced vibration and noise analysis; Denjiryoku reiki ni yoru dendoki no shindo hoshaon kaisekiho

    Energy Technology Data Exchange (ETDEWEB)

    Shiohata, K.; Nemoto, K.; Nagawa, Y.; Sakamoto, S.; Kobayashi, T.; Ito, M.; Koharagi, H. [Hitachi, Ltd, Tokyo (Japan)

    1998-11-01

    In this analysis method, electromagnetic force calculated by 2-dimensional analysis is transformed into external force for 3-dimensional structural-vibration analysis. And a modeling procedure for a vibrating structure is developed. Further, a space-modal-resonance criteria which relates electromagnetic force to structural-vibration or noise is introduced. In the structural-vibration analysis, the finite element method is used; and in the noise analysis, the boundary element method is used. Finally, vibration and noise of an induction motor are calculated using this criteria. Consequently, high-accuracy modeling is achieved and noise the calculated by the simulation almost coincides with that obtained by experiments. And it is clarified that the-space-modal resonance criteria is effective in numerical simulation. 11 refs., 9 figs., 3 tabs.

  3. A Single Electrochemical Probe Used for Analysis of Multiple Nucleic Acid Sequences

    Science.gov (United States)

    Mills, Dawn M.; Calvo-Marzal, Percy; Pinzon, Jeffer M.; Armas, Stephanie; Kolpashchikov, Dmitry M.; Chumbimuni-Torres, Karin Y.

    2017-01-01

    Electrochemical hybridization sensors have been explored extensively for analysis of specific nucleic acids. However, commercialization of the platform is hindered by the need for attachment of separate oligonucleotide probes complementary to a RNA or DNA target to an electrode’s surface. Here we demonstrate that a single probe can be used to analyze several nucleic acid targets with high selectivity and low cost. The universal electrochemical four-way junction (4J)-forming (UE4J) sensor consists of a universal DNA stem-loop (USL) probe attached to the electrode’s surface and two adaptor strands (m and f) which hybridize to the USL probe and the analyte to form a 4J associate. The m adaptor strand was conjugated with a methylene blue redox marker for signal ON sensing and monitored using square wave voltammetry. We demonstrated that a single sensor can be used for detection of several different DNA/RNA sequences and can be regenerated in 30 seconds by a simple water rinse. The UE4J sensor enables a high selectivity by recognition of a single base substitution, even at room temperature. The UE4J sensor opens a venue for a re-useable universal platform that can be adopted at low cost for the analysis of DNA or RNA targets. PMID:29371782

  4. Phase noise analysis of clock recovery based on an optoelectronic phase-locked loop

    DEFF Research Database (Denmark)

    Zibar, Darko; Mørk, Jesper; Oxenløwe, Leif Katsuo

    2007-01-01

    A detailed theoretical analysis of a clock-recovery (CR) scheme based on an optoelectronic phase-locked loop is presented. The analysis emphasizes the phase noise performance, taking into account the noise of the input data signal, the local voltage-controlled oscillator (VCO), and the laser....... It is shown that a large loop length results in a higher timing jitter of the recovered clock signal. The impact of the loop length on the clock signal jitter can be reduced by using a low-noise VCO and a low loop filter bandwidth. Using the model, the timing jitter of the recovered optical and electrical...... clock signal can be evaluated. We numerically investigate the timing jitter requirements for combined electrical/optical local oscillators, in order for the recovered clock signal to have less jitter than that of the input signal. The timing jitter requirements for the free-running laser and the VCO...

  5. Noise-shaping all-digital phase-locked loops modeling, simulation, analysis and design

    CERN Document Server

    Brandonisio, Francesco

    2014-01-01

    This book presents a novel approach to the analysis and design of all-digital phase-locked loops (ADPLLs), technology widely used in wireless communication devices. The authors provide an overview of ADPLL architectures, time-to-digital converters (TDCs) and noise shaping. Realistic examples illustrate how to analyze and simulate phase noise in the presence of sigma-delta modulation and time-to-digital conversion. Readers will gain a deep understanding of ADPLLs and the central role played by noise-shaping. A range of ADPLL and TDC architectures are presented in unified manner. Analytical and simulation tools are discussed in detail. Matlab code is included that can be reused to design, simulate and analyze the ADPLL architectures that are presented in the book.   • Discusses in detail a wide range of all-digital phase-locked loops architectures; • Presents a unified framework in which to model time-to-digital converters for ADPLLs; • Explains a procedure to predict and simulate phase noise in oscil...

  6. Analysis and Extension of the PCA Method, Estimating a Noise Curve from a Single Image

    Directory of Open Access Journals (Sweden)

    Miguel Colom

    2016-12-01

    Full Text Available In the article 'Image Noise Level Estimation by Principal Component Analysis', S. Pyatykh, J. Hesser, and L. Zheng propose a new method to estimate the variance of the noise in an image from the eigenvalues of the covariance matrix of the overlapping blocks of the noisy image. Instead of using all the patches of the noisy image, the authors propose an iterative strategy to adaptively choose the optimal set containing the patches with lowest variance. Although the method measures uniform Gaussian noise, it can be easily adapted to deal with signal-dependent noise, which is realistic with the Poisson noise model obtained by a CMOS or CCD device in a digital camera.

  7. Piribedil affects dopamine turnover in cochleas stimulated by white noise.

    Science.gov (United States)

    Gil-Loyzaga, P; Vicente-Torres, M A; Fernández-Mateos, P; Arce, A; Esquifino, A

    1994-09-01

    The presence of dopamine (DA) within the cochlea has been previously reported, indicating that its turnover increases under noise stimulation. In the present report, piribedil, a dopaminergic D2 agonist, was used in order to provide evidence of the activity of D2 receptors in the turnover of DA under noise stimulation. Long-Evans rats were intraperitoneally injected with distilled water or with a solution of piribedil one hour previously to either noise or silence exposure. Noise stimulation was performed in an anechoic chamber at 70, 90 or 110 dB SPL for one hour. The animals were then sacrificed and the cochlear contents of DA and its metabolites dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) were quantified by HPLC with electrochemical detection. The administration of piribedil to animals kept in silence did not modify the cochlear DA, DOPAC and HVA content. Noise stimulation resulted in a decrease of the cochlear DA content and an increase of the cochlear DOPAC and HVA contents in vehicle treated animals. The administration of piribedil resulted in a blockade of this noise induced cochlear DA turnover. These results suggest that piribedil stimulates cochlear D2 receptors controlling the cochlear DA release. Piribedil action on D2 receptors could explain the improvement observed in some cochleo-vestibular diseases signs after piribedil treatment.

  8. Concatenation of electrochemical grafting with chemical or electrochemical modification for preparing electrodes with specific surface functionality

    International Nuclear Information System (INIS)

    Verma, Pallavi; Maire, Pascal; Novak, Petr

    2011-01-01

    Surface modified electrodes are used in electro-analysis, electro-catalysis, sensors, biomedical applications, etc. and could also be used in batteries. The properties of modified electrodes are determined by the surface functionality. Therefore, the steps involved in the surface modification of the electrodes to obtain specific functionality are of prime importance. We illustrate here bridging of two routes of surface modifications namely electrochemical grafting, and chemical or electrochemical reduction. First, by electrochemical grafting an organic moiety is covalently immobilized on the surface. Then, either by chemical or by electrochemical route the terminal functional group of the grafted moiety is transformed. Using the former route we prepared lithium alkyl carbonate (-O(CH 2 ) 3 OCO 2 Li) modified carbon with potential applications in batteries, and employing the latter we prepared phenyl hydroxyl amine (-C 6 H 4 NHOH) modified carbon which may find application in biosensors. Benzyl alcohol (-C 6 H 4 CH 2 OH) modified carbon was prepared by both chemical as well as electrochemical route. We report combinations of conjugating the two steps of surface modifications and show how the optimal route of terminal functional group modification depends on the chemical nature of the moiety attached to the surface in the electrochemical grafting step.

  9. Concatenation of electrochemical grafting with chemical or electrochemical modification for preparing electrodes with specific surface functionality

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Pallavi; Maire, Pascal [Paul Scherrer Institut, Electrochemistry Laboratory, Section Electrochemical Energy Storage, CH-5232 Villigen PSI (Switzerland); Novak, Petr, E-mail: petr.novak@psi.c [Paul Scherrer Institut, Electrochemistry Laboratory, Section Electrochemical Energy Storage, CH-5232 Villigen PSI (Switzerland)

    2011-04-01

    Surface modified electrodes are used in electro-analysis, electro-catalysis, sensors, biomedical applications, etc. and could also be used in batteries. The properties of modified electrodes are determined by the surface functionality. Therefore, the steps involved in the surface modification of the electrodes to obtain specific functionality are of prime importance. We illustrate here bridging of two routes of surface modifications namely electrochemical grafting, and chemical or electrochemical reduction. First, by electrochemical grafting an organic moiety is covalently immobilized on the surface. Then, either by chemical or by electrochemical route the terminal functional group of the grafted moiety is transformed. Using the former route we prepared lithium alkyl carbonate (-O(CH{sub 2}){sub 3}OCO{sub 2}Li) modified carbon with potential applications in batteries, and employing the latter we prepared phenyl hydroxyl amine (-C{sub 6}H{sub 4}NHOH) modified carbon which may find application in biosensors. Benzyl alcohol (-C{sub 6}H{sub 4}CH{sub 2}OH) modified carbon was prepared by both chemical as well as electrochemical route. We report combinations of conjugating the two steps of surface modifications and show how the optimal route of terminal functional group modification depends on the chemical nature of the moiety attached to the surface in the electrochemical grafting step.

  10. Simulation and stability analysis of supersonic impinging jet noise with microjet control

    Science.gov (United States)

    Hildebrand, Nathaniel; Nichols, Joseph W.

    2014-11-01

    A model for an ideally expanded 1.5 Mach turbulent jet impinging on a flat plate using unstructured high-fidelity large eddy simulations (LES) and hydrodynamic stability analysis is presented. Note the LES configuration conforms exactly to experiments performed at the STOVL supersonic jet facility of the Florida Center for Advanced Aero-Propulsion allowing validation against experimental measurements. The LES are repeated for different nozzle-wall separation distances as well as with and without the addition of sixteen microjets positioned uniformly around the nozzle lip. For some nozzle-wall distances, but not all, the microjets result in substantial noise reduction. Observations of substantial noise reduction are associated with a relative absence of large-scale coherent vortices in the jet shear layer. To better understand and predict the effectiveness of microjet noise control, the application of global stability analysis about LES mean fields is used to extract axisymmetric and helical instability modes connected to the complex interplay between the coherent vortices, shocks, and acoustic feedback. We gratefully acknowledge computational resources provided by the Argonne Leadership Computing Facility.

  11. Partial and Total Annoyance Due to Road Traffic Noise Combined with Aircraft or Railway Noise: Structural Equation Analysis

    OpenAIRE

    Gille, Laure-Anne; Marquis-Favre, Catherine; Lam, Kin-Che

    2017-01-01

    Structural equation modeling was used to analyze partial and total in situ annoyance in combined transportation noise situations. A psychophysical total annoyance model and a perceptual total annoyance model were proposed. Results show a high contribution of Noise exposure and Noise sensitivity to Noise annoyance, as well as a causal relationship between noise annoyance and lower Dwelling satisfaction. Moreover, the Visibility of noise source may increase noise annoyance, even when the visibl...

  12. Evaluation of noise pollution in oil extracting region of Lavan and the effect of noise enclosure on noise abatement

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2007-09-01

    Full Text Available Background and aims   Overexposure to industrial noise pollution induce hearing loss workers. Occupational hearing loss may cause interference whit oral communication, so it may  increase the risk of occupational accidents in workplace as well as affects whit social activities.  This study was conducted on Lavan Island, are of oil extracting regions in the south of Iran. The  object of this study was to evaluate noise pollution and determining the effect of noise enclosure  on noise abatement.   Methods   The noise sources were recognized and noise pressure level was measured by CEL- 440. Noise dose of the exposed workers in high level noise area were measured by CEL 272.   Results   Major noise sources were gas turbines, diesel generators, compressors, fans and gas containing pips, noise contour map revealers that noise level were higher than the recommended national exposure limit. The results of workers noise dose show that their noise exposure were  higher than the recommended value, (p<0.001. Finally, by using the results of noise frequency  analysis of different noise sources, the noise pressure level of each sources was determined in   terms of enclosing them.   Conclusion   By enclosing the noise sources, noise pressure levels can be lowered douse to  acceptable levels but limitation of applying enclosure should be regarded.  

  13. Electrochemical Energy Storage Technical Team Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-06-01

    This U.S. DRIVE electrochemical energy storage roadmap describes ongoing and planned efforts to develop electrochemical energy storage technologies for plug-in electric vehicles (PEVs). The Energy Storage activity comprises a number of research areas (including advanced materials research, cell level research, battery development, and enabling R&D which includes analysis, testing and other activities) for advanced energy storage technologies (batteries and ultra-capacitors).

  14. Neutron noise analysis of BWR using time series analysis

    International Nuclear Information System (INIS)

    Fukunishi, Kohyu

    1976-01-01

    The main purpose of this paper is to give more quantitative understanding of noise source in neutron flux and to provide a useful tool for the detection and diagnosis of reactor. The space dependent effects of distributed neutron flux signals at the axial direction of two different strings are investigated by the power contribution ratio among neutron fluxes and the incoherent noise spectra of neutron fluxes derived from autoregressive spectra. The signals are measured on the medium sized commercial BWR of 460 MWe in Japan. From the obtained results, local and global noise sources in neutron flux are discussed. This method is indicated to be a useful tool for detection and diagnosis of anomalous phenomena in BWR. (orig./RW) [de

  15. Application of noise analysis for the study of core local instability at Forsmark 1

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1997-10-01

    Core local instability was recently experienced at Forsmark 1 BWR. The event has been studied by applying noise analysis to data collected in January 1997 for the stability test. The result indicated that there was a region in the left corner of the core which was subject to instability due to neutronic and thermal-hydraulic coupling. The result of the noise analysis suggested two types of disturbance source, one in the vicinity of the detector string LPRM10 having resonant oscillation at 0.5 Hz and another relatively wide band noise in the neighbourhood of LPRM18. Three hypotheses have been examined as the possible cause, operational factor, abnormal fuel assembly, and wide band low frequency disturbance. Although the real cause has not been made clear from the noise analysis, it is likely that the operational factor played an important role as the cause. Further investigations are expected to be performed in the future. In order to detect the local instability it is important to have a stability monitor with a capability of monitoring a sufficient number of LPRMs so as to cover the whole core. This is important since local instability is a type of anomaly which should not occur during reactor operation

  16. Seismic Background Noise Analysis of BRTR (PS-43) Array

    Science.gov (United States)

    Ezgi Bakir, Mahmure; Meral Ozel, Nurcan; Umut Semin, Korhan

    2015-04-01

    The seismic background noise variation of BRTR array, composed of two sub arrays located in Ankara and in Ankara-Keskin, has been investigated by calculating Power Spectral Density and Probability Density Functions for seasonal and diurnal noise variations between 2005 and 2011. PSDs were computed within the frequency range of 100 s - 10 Hz. The results show us a little change in noise conditions in terms of time and location. Especially, noise level changes were observed at 3-5 Hz in diurnal variations at Keskin array and there is a 5-7 dB difference in day and night time in cultural noise band (1-10 Hz). On the other hand, noise levels of medium period array is high in 1-2 Hz frequency rather than short period array. High noise levels were observed in daily working times when we compare it to night-time in cultural noise band. The seasonal background noise variation at both sites also shows very similar properties to each other. Since these stations are borehole instruments and away from the coasts, we saw a small change in noise levels caused by microseism. Comparison between Keskin short period array and Ankara medium period array show us Keskin array is quiter than Ankara array.

  17. Noise analysis of fluid-valve system in a linear compressor using CAE

    International Nuclear Information System (INIS)

    Lee, Jun Ho; Jeong, Weui Bong; Kim, Dang Ju

    2009-01-01

    A linear compressor in a refrigerator uses piston motion to transfer refrigerant so its efficiency is higher than a previous reciprocal compressor. Because of interaction between refrigerant and valves system in the linear compressor, however, noise has been a main issue. In spite of doing many experimental researches, there is no way to rightly predict the noise. In order to solve this limitation, the CAE analysis is applied. For giving credit to these computational data, all of the data are experimentally validated.

  18. Analysis of regularized inversion of data corrupted by white Gaussian noise

    International Nuclear Information System (INIS)

    Kekkonen, Hanne; Lassas, Matti; Siltanen, Samuli

    2014-01-01

    Tikhonov regularization is studied in the case of linear pseudodifferential operator as the forward map and additive white Gaussian noise as the measurement error. The measurement model for an unknown function u(x) is m(x) = Au(x) + δ ε (x), where δ > 0 is the noise magnitude. If ε was an L 2 -function, Tikhonov regularization gives an estimate T α (m) = u∈H r arg min { ||Au-m|| L 2 2 + α||u|| H r 2 } for u where α = α(δ) is the regularization parameter. Here penalization of the Sobolev norm ||u|| H r covers the cases of standard Tikhonov regularization (r = 0) and first derivative penalty (r = 1). Realizations of white Gaussian noise are almost never in L 2 , but do belong to H s with probability one if s < 0 is small enough. A modification of Tikhonov regularization theory is presented, covering the case of white Gaussian measurement noise. Furthermore, the convergence of regularized reconstructions to the correct solution as δ → 0 is proven in appropriate function spaces using microlocal analysis. The convergence of the related finite-dimensional problems to the infinite-dimensional problem is also analysed. (paper)

  19. Robust spinal cord resting-state fMRI using independent component analysis-based nuisance regression noise reduction.

    Science.gov (United States)

    Hu, Yong; Jin, Richu; Li, Guangsheng; Luk, Keith Dk; Wu, Ed X

    2018-04-16

    Physiological noise reduction plays a critical role in spinal cord (SC) resting-state fMRI (rsfMRI). To reduce physiological noise and increase the robustness of SC rsfMRI by using an independent component analysis (ICA)-based nuisance regression (ICANR) method. Retrospective. Ten healthy subjects (female/male = 4/6, age = 27 ± 3 years, range 24-34 years). 3T/gradient-echo echo planar imaging (EPI). We used three alternative methods (no regression [Nil], conventional region of interest [ROI]-based noise reduction method without ICA [ROI-based], and correction of structured noise using spatial independent component analysis [CORSICA]) to compare with the performance of ICANR. Reduction of the influence of physiological noise on the SC and the reproducibility of rsfMRI analysis after noise reduction were examined. The correlation coefficient (CC) was calculated to assess the influence of physiological noise. Reproducibility was calculated by intraclass correlation (ICC). Results from different methods were compared by one-way analysis of variance (ANOVA) with post-hoc analysis. No significant difference in cerebrospinal fluid (CSF) pulsation influence or tissue motion influence were found (P = 0.223 in CSF, P = 0.2461 in tissue motion) in the ROI-based (CSF: 0.122 ± 0.020; tissue motion: 0.112 ± 0.015), and Nil (CSF: 0.134 ± 0.026; tissue motion: 0.124 ± 0.019). CORSICA showed a significantly stronger influence of CSF pulsation and tissue motion (CSF: 0.166 ± 0.045, P = 0.048; tissue motion: 0.160 ± 0.032, P = 0.048) than Nil. ICANR showed a significantly weaker influence of CSF pulsation and tissue motion (CSF: 0.076 ± 0.007, P = 0.0003; tissue motion: 0.081 ± 0.014, P = 0.0182) than Nil. The ICC values in the Nil, ROI-based, CORSICA, and ICANR were 0.669, 0.645, 0.561, and 0.766, respectively. ICANR more effectively reduced physiological noise from both tissue motion and CSF pulsation than three alternative methods. ICANR increases the robustness of SC rsf

  20. Poisson–Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain

    Science.gov (United States)

    Lee, Sangyoon; Lee, Min Seok; Kang, Moon Gi

    2018-01-01

    The noise distribution of images obtained by X-ray sensors in low-dosage situations can be analyzed using the Poisson and Gaussian mixture model. Multiscale conversion is one of the most popular noise reduction methods used in recent years. Estimation of the noise distribution of each subband in the multiscale domain is the most important factor in performing noise reduction, with non-subsampled contourlet transform (NSCT) representing an effective method for scale and direction decomposition. In this study, we use artificially generated noise to analyze and estimate the Poisson–Gaussian noise of low-dose X-ray images in the NSCT domain. The noise distribution of the subband coefficients is analyzed using the noiseless low-band coefficients and the variance of the noisy subband coefficients. The noise-after-transform also follows a Poisson–Gaussian distribution, and the relationship between the noise parameters of the subband and the full-band image is identified. We then analyze noise of actual images to validate the theoretical analysis. Comparison of the proposed noise estimation method with an existing noise reduction method confirms that the proposed method outperforms traditional methods. PMID:29596335

  1. Poisson-Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain.

    Science.gov (United States)

    Lee, Sangyoon; Lee, Min Seok; Kang, Moon Gi

    2018-03-29

    The noise distribution of images obtained by X-ray sensors in low-dosage situations can be analyzed using the Poisson and Gaussian mixture model. Multiscale conversion is one of the most popular noise reduction methods used in recent years. Estimation of the noise distribution of each subband in the multiscale domain is the most important factor in performing noise reduction, with non-subsampled contourlet transform (NSCT) representing an effective method for scale and direction decomposition. In this study, we use artificially generated noise to analyze and estimate the Poisson-Gaussian noise of low-dose X-ray images in the NSCT domain. The noise distribution of the subband coefficients is analyzed using the noiseless low-band coefficients and the variance of the noisy subband coefficients. The noise-after-transform also follows a Poisson-Gaussian distribution, and the relationship between the noise parameters of the subband and the full-band image is identified. We then analyze noise of actual images to validate the theoretical analysis. Comparison of the proposed noise estimation method with an existing noise reduction method confirms that the proposed method outperforms traditional methods.

  2. Association between exposure to noise and risk of hypertension: a meta-analysis of observational epidemiological studies.

    Science.gov (United States)

    Fu, Wenning; Wang, Chao; Zou, Li; Liu, Qiaoyan; Gan, Yong; Yan, Shijiao; Song, Fujian; Wang, Zhihong; Lu, Zuxun; Cao, Shiyi

    2017-12-01

    An increasing amount of original studies suggested that exposure to noise could be associated with the risk of hypertension, but the results remain inconsistent and inconclusive. We aimed to synthesize available epidemiological evidence about the relationship between various types of noise and hypertension, and to explore the potential dose-response relationship between them in an up-to-date meta-analysis. We conducted a literature search of PubMed and Embase from these databases' inception through December 2016 to identify observational epidemiological studies examining the association between noise and risk of hypertension. A random effects model was used to combine the results of included studies. Dose-response meta-analysis was conducted to examine the potential dose-response relationship. In total, 32 studies (five cohort studies, one case-control study, and 26 cross-section studies) involving 264 678 participants were eligible for inclusion. Pooled result showed that living or working in environment with noise exposure was significantly associated with increased risk of hypertension (odds ratio 1.62; 95% confidence interval: 1.40-1.88). We found no evidence of a curve linear association between noise and risk of hypertension. A dose-response analysis suggested that, for an increment of per 10 dB(A) of noise, the combined odds ratio of hypertension was 1.06 (95% confidence interval: 1.04-1.08). Integrated epidemiological evidence supports the hypothesis that exposure to noise may be a risk factor of hypertension, and there is a positive dose-response association between them.

  3. Period analysis at high noise level

    International Nuclear Information System (INIS)

    Kovacs, G.

    1980-01-01

    Analytical expressions are derived for the variances of some types of the periodograms due to normal-distributed noise present in the data. The equivalence of the Jurkevich and the Warner and Robinson methods is proved. The optimum phase cell number of the Warner and Robinson method is given; this number depends on the data length, signal form and noise level. The results are illustrated by numerical examples. (orig.)

  4. An Application of the Acoustic Similarity Law to the Numerical Analysis of Centrifugal Fan Noise

    Science.gov (United States)

    Jeon, Wan-Ho; Lee, Duck-Joo; Rhee, Huinam

    Centrifugal fans, which are frequently used in our daily lives and various industries, usually make severe noise problems. Generally, the centrifugal fan noise consists of tones at the blade passing frequency and its higher harmonics. These tonal sounds come from the interaction between the flow discharged from the impeller and the cutoff in the casing. Prediction of the noise from a centrifugal fan becomes more necessary to optimize the design to meet both the performance and noise criteria. However, only some limited studies on noise prediction method exist because there are difficulties in obtaining detailed information about the flow field and casing effect on noise radiation. This paper aims to investigate the noise generation mechanism of a centrifugal fan and to develop a prediction method for the unsteady flow and acoustic pressure fields. In order to do this, a numerical analysis method using acoustic similarity law is proposed, and it is verified that the method can predict the noise generation mechanism very well by comparing the predicted results with available experimental results.

  5. Automated pattern recognition system for noise analysis

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Piety, K.R.

    1980-01-01

    A pattern recognition system was developed at ORNL for on-line monitoring of noise signals from sensors in a nuclear power plant. The system continuousy measures the power spectral density (PSD) values of the signals and the statistical characteristics of the PSDs in unattended operation. Through statistical comparison of current with past PSDs (pattern recognition), the system detects changes in the noise signals. Because the noise signals contain information about the current operational condition of the plant, a change in these signals could indicate a change, either normal or abnormal, in the operational condition

  6. Lifetime measurement of prompt neutrons using the neutronic noise analysis

    International Nuclear Information System (INIS)

    Ortiz Servin, J.J.

    1992-01-01

    The purpose of this work is to estimate the life of the prompt neutrons, i, of a nuclear reactor utilizing the neutron noise analysis. This technique carry to development of mathematical model that is valid for lower powers reactor. The equation resulting convey to the observation about power spectrum behaviour respect to the frecquency. In this case, the reactor in study is the Triga Mark III of Nuclear Center of Mexico that it was provided of fission chambers for register the neutron fluxes. These fluxes was digitized and storage in computer disc as signals dependents of time, for later apply the Fourier Transformation and obtain the spectras. The spectras measured to different reactor powers were adjusted to the development equation before, using the method of square minimum and so estimate the parameter i. The analysis of results throw a value of 22.73 +/- 0.92 μs. On the other hand, the calculate value to the resolve the kinetic equation of reactor defer in lower than 4 % about the estimate. Of this, it concludes that the model utilized is trusty with a good mistake margin, moreover of that the technique of Neutron Noise analysis demonstrate be competitive (Author)

  7. Room acoustic analysis of blower unit and noise control plan in the typical steel industry

    Directory of Open Access Journals (Sweden)

    2013-02-01

    Full Text Available Introduction: In the steel industry,air blowers used to supply compressed air are considered as sources of annoying noise. This study aims to acoustics analysis of theairblower workroomand sound source characteristics in order to present noise controlmeasuresinthe steel industry. .Material and Method: Measurement of noiselevel and its frequency analysis was performed usingsound levelmetermodelof CASELLA-Cell.450. Distribution of noise level in the investigated workroom in form of noise map was provided using Surfer software. In addition, acoustic analysis of workroom and control room was performed in view point of soundabsorption andinsulation. Redesignofdoor and window of controlroom and installation of soundabsorbing materialson theceiling of the workroom were proposed and the efficiency of these interventionswasestimated. .Result: The totalsound pressurelevelin the blower workroom was 95.4 dB(L and the dominant frequency was 2000Hz. Sound pressure level inside the room control was 80.1dB(A. The average absorption coefficient and reverberation time in the blower workroom was estimated equal to 0.082 Sab.m2 and 3.9 seconds respectively. These value in control room was 0.04 Sab.m2 and 3/4 seconds respectively. In control room, sound transmission loss between the two parts of the wall dividing was 13.7 dB(A. The average of noise dose in blower operators was 230%. With the installation of sound absorber on ceiling of workroom, average of absorption coefficient can increase to 0.33 Sab.m2 and sound transmission loss of the new designed door and window was estimated equal to 20dB. . Conclusion: The main cause of noise leakage in the control room was insufficient insulation properties of door and windows. By replacing the door and window and installation of sound absorbing on ceiling of workroom, the noise dose can reduce to 49.6%. New Improved door and window of control room can reduce noise dose to 69.65% solely.

  8. Croatian Experience in Road Traffic Noise Management - Concrete Noise Barriers

    Directory of Open Access Journals (Sweden)

    Ahac Saša

    2014-07-01

    Full Text Available The paper gives an overview of concrete noise barrier application in several EU countries and in Croatia. It describes a process of introducing different noise protection solutions on Croatian market in the phase of intensive motorway construction in recent years. Namely, an extensive motorway network has been constructed in Croatia in the last 10 years. Following the process of motorway construction, noise protection walls have also been erected. Usage of different building materials and installation processes as well as variations in building expenditures has led to a comparative analysis of several types of noise protection solutions (expanded clay, wood fibre including a new eco-innovative product RUCONBAR, which incorporates rubber granules from recycled waste tyres to form a porous noise absorptive layer.

  9. Noise control in aeroacoustics; Proceedings of the 1993 National Conference on Noise Control Engineering, NOISE-CON 93, Williamsburg, VA, May 2-5, 1993

    Science.gov (United States)

    Hubbard, Harvey H. (Editor)

    1993-01-01

    In the conference over 100 papers were presented in eight sessions: (1) Emission: Noise Sources; (2) Physical Phenomena; (3) Noise ControlElements; (4) Vibration and Shock: Generation, Transmission, Isolation, and Reduction; (5) Immission: Physical Aspects of Environmental Noise; (6) Immission: Effects of Noise; (7) Analysis; and (8) Requirements. In addition, the distinguished lecture series included presentations on the High Speed Civil Transport and on research from the United Kingdom on aircraft noise effects.

  10. Numerical noise analysis for insulator of overhead transmission line

    Science.gov (United States)

    Zhang, Yulin; Chen, Yuwen; Huang, Yu

    2018-04-01

    As an important and complex issue in aero acoustic field, a lot of explorations have been devoted to the wind-induced noise. However, there is still lack of intensive investigations for aerodynamic noise in high-voltage transmission. The overhead transmission line system leads to serious occupational noise exposure in high wind-speed environment, and the noise can even injure the electricians in charge of insulator. By using computational fluid dynamics (CFD) which combined with computational aero acoustics (CAA), this paper predicts the noise generated by insulator of high voltage electricity transmission line which explores in wind environment. The simulation results indicate that the wind velocity, the assembly angle of the insulator and its ribs' distribution are the main contributory factors for the aerodynamic noise. Specifically, when wind velocity is greater than 15m/s, the alteration of noise is not sensitive to the wind velocity; furthermore, when the assembly angle increases from 0°to 60°, the noise decreases gradually, however, if the angle is happening to be 75°or 90°, it would be even greater than that at 0°. In order to inhibit the aerodynamic noise, it is necessary to control the flow blowing across the boundary of the insulator. Consequently, the result indicates that if the outermost rib is shorter than the second one, the noise reduced evidently. This information expects to provide useful help for the extremely suppression of aerodynamic noise, and also supply practical reference material for the design and application of overhead transmission line system.

  11. A noise reduction technique based on nonlinear kernel function for heart sound analysis.

    Science.gov (United States)

    Mondal, Ashok; Saxena, Ishan; Tang, Hong; Banerjee, Poulami

    2017-02-13

    The main difficulty encountered in interpretation of cardiac sound is interference of noise. The contaminated noise obscures the relevant information which are useful for recognition of heart diseases. The unwanted signals are produced mainly by lungs and surrounding environment. In this paper, a novel heart sound de-noising technique has been introduced based on a combined framework of wavelet packet transform (WPT) and singular value decomposition (SVD). The most informative node of wavelet tree is selected on the criteria of mutual information measurement. Next, the coefficient corresponding to the selected node is processed by SVD technique to suppress noisy component from heart sound signal. To justify the efficacy of the proposed technique, several experiments have been conducted with heart sound dataset, including normal and pathological cases at different signal to noise ratios. The significance of the method is validated by statistical analysis of the results. The biological information preserved in de-noised heart sound (HS) signal is evaluated by k-means clustering algorithm and Fit Factor calculation. The overall results show that proposed method is superior than the baseline methods.

  12. Image Denoising Algorithm Combined with SGK Dictionary Learning and Principal Component Analysis Noise Estimation

    Directory of Open Access Journals (Sweden)

    Wenjing Zhao

    2018-01-01

    Full Text Available SGK (sequential generalization of K-means dictionary learning denoising algorithm has the characteristics of fast denoising speed and excellent denoising performance. However, the noise standard deviation must be known in advance when using SGK algorithm to process the image. This paper presents a denoising algorithm combined with SGK dictionary learning and the principal component analysis (PCA noise estimation. At first, the noise standard deviation of the image is estimated by using the PCA noise estimation algorithm. And then it is used for SGK dictionary learning algorithm. Experimental results show the following: (1 The SGK algorithm has the best denoising performance compared with the other three dictionary learning algorithms. (2 The SGK algorithm combined with PCA is superior to the SGK algorithm combined with other noise estimation algorithms. (3 Compared with the original SGK algorithm, the proposed algorithm has higher PSNR and better denoising performance.

  13. Noise, a tool for analysis of neutronic impact noise; Noise, Una herramienta para el analisis del impacto del ruido neutronico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Escobar, A.; Lopez Cedillo, A.; Ortego Inigo, A.; Ortega Pascual, F.

    2013-07-01

    The NOISE application is an off-line tool developed by TECNATOM for Trillo, which simulates the power calculation circuit protection system and L-RELEB system function limitation. It is fed with real data of neutron flux with a frequency of 100 Hz and is designed for predictive analysis system alarms limitation as a result of the oscillations of neutron flux measurements. Addition is to be used as a tool for engineering support to adjust the effective value of the dead band surround filters preventing possible system alarms cause impact on the operation.

  14. 3D seismic data de-noising and reconstruction using Multichannel Time Slice Singular Spectrum Analysis

    Science.gov (United States)

    Rekapalli, Rajesh; Tiwari, R. K.; Sen, Mrinal K.; Vedanti, Nimisha

    2017-05-01

    Noises and data gaps complicate the seismic data processing and subsequently cause difficulties in the geological interpretation. We discuss a recent development and application of the Multi-channel Time Slice Singular Spectrum Analysis (MTSSSA) for 3D seismic data de-noising in time domain. In addition, L1 norm based simultaneous data gap filling of 3D seismic data using MTSSSA also discussed. We discriminated the noises from single individual time slices of 3D volumes by analyzing Eigen triplets of the trajectory matrix. We first tested the efficacy of the method on 3D synthetic seismic data contaminated with noise and then applied to the post stack seismic reflection data acquired from the Sleipner CO2 storage site (pre and post CO2 injection) from Norway. Our analysis suggests that the MTSSSA algorithm is efficient to enhance the S/N for better identification of amplitude anomalies along with simultaneous data gap filling. The bright spots identified in the de-noised data indicate upward migration of CO2 towards the top of the Utsira formation. The reflections identified applying MTSSSA to pre and post injection data correlate well with the geology of the Southern Viking Graben (SVG).

  15. Conformational analysis of large and highly disulfide-stabilized proteins by integrating online electrochemical reduction into an optimized H/D exchange mass spectrometry workflow

    DEFF Research Database (Denmark)

    Trabjerg, Esben; Jakobsen, Rasmus Uffe; Mysling, Simon

    2015-01-01

    Analysis of disulfide-bonded proteins by HDX-MS requires effective and rapid reduction of disulfide bonds before enzymatic digestion in order to increase sequence coverage. In a conventional HDX-MS workflow, disulfide bonds are reduced chemically by addition of a reducing agent to the quench......-antibody, respectively. The presented results demonstrate the successful electrochemical reduction during HDX-MS analysis of both a small exceptional tightly disulfide-bonded protein (NGF) as well as the largest protein attempted to date (IgG1-antibody). We envision that online electrochemical reduction...... the electrochemical reduction efficiency during HDX-MS analysis of two particularly challenging disulfide stabilized proteins: a therapeutic IgG1-antibody and Nerve Growth Factor-β (NGF). Several different parameters (flow rate, applied square wave potential as well as the type of labeling- and quench buffer) were...

  16. The analysis of transient noise of PCB P/G network based on PI/SI co-simulation

    Science.gov (United States)

    Haohang, Su

    2018-02-01

    With the frequency of the space camera become higher than before, the power noise of the imaging electronic system become the important factor. Much more power noise would disturb the transmissions signal, and even influence the image sharpness and system noise. "Target impedance method" is one of the traditional design method of P/G network (power and ground network), which is shorted of transient power noise analysis and often made "over design". In this paper, a new design method of P/G network is provided which simulated by PI/SI co-simulation. The transient power noise can be simulated and then applied in the design of noise reduction, thus effectively controlling the change of the noise in the P/G network. The method can efficiently control the number of adding decoupling capacitor, and is very efficient and feasible to keep the power integrity.

  17. An Analysis of Sawtooth Noise in the Timing SynPaQ III GPS Sensor

    Directory of Open Access Journals (Sweden)

    Yuriy S. SHMALIY

    2007-05-01

    Full Text Available This paper addresses a probabilistic analysis of sawtooth noise in the one pulse per second (1PPS output of the timing SynPaQ III GPS Sensor. We show that sawtooth noise is uniformly distributed within the bounds caused by period of the Local Time Clock of the sensor and that the probability density function (pdf of this noise is formed with 1ns sampling interval used in the sensor to calculate the negative sawtooth. We also show that the pdf has at zero a spike of 1ns width caused by roll-off. It is demonstrated that an unbiased finite impulse response filter is an excellent suppresser of such a noise in the estimates of the time interval errors of local clocks.

  18. Electrochemical immunosensors - A powerful tool for analytical applications.

    Science.gov (United States)

    Felix, Fabiana S; Angnes, Lúcio

    2018-04-15

    Immunosensors are biosensors based on interactions between an antibody and antigen on a transducer surface. Either antibody or antigen can be the species immobilized on the transducer to detect antigen or antibody, respectively. Because of the strong binding forces between these biomolecules, immunosensors present high selectivity and very high sensitivity, making them very attractive for many applications in different science fields. Electrochemical immunosensors explore measurements of an electrical signal produced on an electrochemical transductor. This signal can be voltammetric, potentiometric, conductometric or impedimetric. Immunosensors utilizing electrochemical detection have been explored in several analyses since they are specific, simple, portable, and generally disposable and can carry out in situ or automated detection. This review addresses the potential of immunosensors destined for application in food and environmental analysis, and cancer biomarker diagnosis. Emphasis is given to the approaches that have been used for construction of electrochemical immunosensors. Additionally, the fundamentals of immunosensors, technology of transducers and nanomaterials and a general overview of the possible applications of electrochemical immunosensors to the food, environmental and diseases analysis fields are described. Copyright © 2017. Published by Elsevier B.V.

  19. Sound the alarm: A meta-analysis on the effect of aquatic noise on fish behavior and physiology.

    Science.gov (United States)

    Cox, Kieran; Brennan, Lawrence P; Gerwing, Travis G; Dudas, Sarah E; Juanes, Francis

    2018-07-01

    The aquatic environment is increasingly bombarded by a wide variety of noise pollutants whose range and intensity are increasing with each passing decade. Yet, little is known about how aquatic noise affects marine communities. To determine the implications that changes to the soundscape may have on fishes, a meta-analysis was conducted focusing on the ramifications of noise on fish behavior and physiology. Our meta-analysis identified 42 studies that produced 2,354 data points, which in turn indicated that anthropogenic noise negatively affects fish behavior and physiology. The most predominate responses occurred within foraging ability, predation risk, and reproductive success. Additionally, anthropogenic noise was shown to increase the hearing thresholds and cortisol levels of numerous species while tones, biological, and environmental noise were most likely to affect complex movements and swimming abilities. These findings suggest that the majority of fish species are sensitive to changes in the aquatic soundscape, and depending on the noise source, species responses may have extreme and negative fitness consequences. As such, this global synthesis should serve as a warning of the potentially dire consequences facing marine ecosystems if alterations to aquatic soundscapes continue on their current trajectory. © 2018 John Wiley & Sons Ltd.

  20. Automotive Exterior Noise Optimization Using Grey Relational Analysis Coupled with Principal Component Analysis

    Science.gov (United States)

    Chen, Shuming; Wang, Dengfeng; Liu, Bo

    This paper investigates optimization design of the thickness of the sound package performed on a passenger automobile. The major characteristics indexes for performance selected to evaluate the processes are the SPL of the exterior noise and the weight of the sound package, and the corresponding parameters of the sound package are the thickness of the glass wool with aluminum foil for the first layer, the thickness of the glass fiber for the second layer, and the thickness of the PE foam for the third layer. In this paper, the process is fundamentally with multiple performances, thus, the grey relational analysis that utilizes grey relational grade as performance index is especially employed to determine the optimal combination of the thickness of the different layers for the designed sound package. Additionally, in order to evaluate the weighting values corresponding to various performance characteristics, the principal component analysis is used to show their relative importance properly and objectively. The results of the confirmation experiments uncover that grey relational analysis coupled with principal analysis methods can successfully be applied to find the optimal combination of the thickness for each layer of the sound package material. Therefore, the presented method can be an effective tool to improve the vehicle exterior noise and lower the weight of the sound package. In addition, it will also be helpful for other applications in the automotive industry, such as the First Automobile Works in China, Changan Automobile in China, etc.

  1. Noise sensitivity, rather than noise level, predicts the non-auditory effects of noise in community samples: a population-based survey

    Directory of Open Access Journals (Sweden)

    Jangho Park

    2017-04-01

    Full Text Available Abstract Background Excessive noise affects human health and interferes with daily activities. Although environmental noise may not directly cause mental illness, it may accelerate and intensify the development of latent mental disorders. Noise sensitivity (NS is considered a moderator of non-auditory noise effects. In the present study, we aimed to assess whether NS is associated with non-auditory effects. Methods We recruited a community sample of 1836 residents residing in Ulsan and Seoul, South Korea. From July to November 2015, participants were interviewed regarding their demographic characteristics, socioeconomic status, medical history, and NS. The non-auditory effects of noise were assessed using the Center of Epidemiologic Studies Depression, Insomnia Severity index, State Trait Anxiety Inventory state subscale, and Stress Response Inventory-Modified Form. Individual noise levels were recorded from noise maps. A three-model multivariate logistic regression analysis was performed to identify factors that might affect psychiatric illnesses. Results Participants ranged in age from 19 to 91 years (mean: 47.0 ± 16.1 years, and 37.9% (n = 696 were male. Participants with high NS were more likely to have been diagnosed with diabetes and hyperlipidemia and to use psychiatric medication. The multivariable analysis indicated that even after adjusting for noise-related variables, sociodemographic factors, medical illness, and duration of residence, subjects in the high NS group were more than 2 times more likely to experience depression and insomnia and 1.9 times more likely to have anxiety, compared with those in the low NS group. Noise exposure level was not identified as an explanatory value. Conclusions NS increases the susceptibility and hence moderates there actions of individuals to noise. NS, rather than noise itself, is associated with an elevated susceptibility to non-auditory effects.

  2. A CAMAC based real-time noise analysis system for nuclear reactors

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1987-01-01

    A CAMAC based real-time noise analysis system was designed for the TRIGA MARK II nuclear reactor at the Institute for Nuclear Energy, Istanbul. The input analog signals obtained from the radiation detectors are introduced to the system through CAMAC interface. The signals coverted into digital form are processed by a PDP-11 computer. The fast data processing based on auto/cross power spectral density computations is carried out by means of assembly written FFT algorithms in real-time and the spectra obtained are displayed on a CAMAC driven display system as an additional monitoring device. The system has the advantage of being software programmable and controlled by a CAMAC system so that it is operated under porgram control for reactor surveillance, anomaly detection and diagnosis. The system can also be used for the identification of nonstationary operational characteristics of the reactor in long term by comparing the noise power spectra with the corresponding reference noise patterns prepared in advance. (orig.)

  3. Analysis of jet-airfoil interaction noise sources by using a microphone array technique

    Science.gov (United States)

    Fleury, Vincent; Davy, Renaud

    2016-03-01

    The paper is concerned with the characterization of jet noise sources and jet-airfoil interaction sources by using microphone array data. The measurements were carried-out in the anechoic open test section wind tunnel of Onera, Cepra19. The microphone array technique relies on the convected, Lighthill's and Ffowcs-Williams and Hawkings' acoustic analogy equation. The cross-spectrum of the source term of the analogy equation is sought. It is defined as the optimal solution to a minimal error equation using the measured microphone cross-spectra as reference. This inverse problem is ill-posed yet. A penalty term based on a localization operator is therefore added to improve the recovery of jet noise sources. The analysis of isolated jet noise data in subsonic regime shows the contribution of the conventional mixing noise source in the low frequency range, as expected, and of uniformly distributed, uncorrelated noise sources in the jet flow at higher frequencies. In underexpanded supersonic regime, a shock-associated noise source is clearly identified, too. An additional source is detected in the vicinity of the nozzle exit both in supersonic and subsonic regimes. In the presence of the airfoil, the distribution of the noise sources is deeply modified. In particular, a strong noise source is localized on the flap. For high Strouhal numbers, higher than about 2 (based on the jet mixing velocity and diameter), a significant contribution from the shear-layer near the flap is observed, too. Indications of acoustic reflections on the airfoil are also discerned.

  4. Analysis of landing gear noise during approach

    NARCIS (Netherlands)

    Merino Martinez, R.; Snellen, M.; Simons, D.G.

    2016-01-01

    Airframe noise is becoming increasingly important during approach, even reaching higher noise levels than the engines in some cases. More people are a_ected due to low ight altitudes and _xed tra_c routing associated with typical approaches. For most air- craft types, the landing gear system is a

  5. β-Cyclodextrin polymer functionalized reduced-graphene oxide: Application for electrochemical determination imidacloprid

    International Nuclear Information System (INIS)

    Chen, Ming; Meng, Yang; Zhang, Wang; Zhou, Jun; Xie, Ju; Diao, Guowang

    2013-01-01

    Highlights: • β-CDP/rGO nanocomposites were prepared by a facile strategy. • β-CDP/rGO nanocomposites displayed the excellent water-dispersity and stability. • β-CDP/rGO exhibited high supramolecular recognition and enrichment capability. • β-CDP/rGO electrode showed excellent electrochemical performance for IDP. -- Abstract: Reduced-graphene oxide (rGO) modified with water-soluble β-cyclodextrin polymer (β-CDP) were successfully prepared by using a simple wet chemical strategy. The obtained β-CDP/rGO nanocomposites were characterized by Fourier transform infrared spectroscopy (FTIR), static contact angle measurement, thermogravimetric analysis (TGA), scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS), which confirmed that β-CDP molecules had been effectively loaded onto the surface of rGO. β-CDP/rGO nanocomposites displayed the excellent water-dispersity and stability. More significantly, cyclic voltammetry and differential pulse voltammetry measurement showed that the β-CDP/rGO could exhibit high supramolecular recognition and enrichment capability, and consequently display excellent electrochemical response toward a pesticide-imidacloprid (IDP). As compared with various modified electrodes, β-CDP/rGO modified glassy carbon electrode exhibited an excellent electrochemical performance for IDP. Based on the cyclic voltammograms (CV) of different concentration of IDP at pH 6.8, the detection line range of IDP is 1 × 10 −6 to 1.5 × 10 −4 mol L −1 IDP and the detection limit is 1 × 10 −7 mol L −1 . Differential pulse voltammetry (DPV) measurement at β-CDP/rGO/GCE modified electrode revealed that the reduction peak current increased linearly with the concentration of IDP in linear range of 5 × 10 −8 to 1.5 × 10 −5 mol L −1 and 2 × 10 −5 to 1.5 × 10 −4 mol L −1 with detection limit of 2 × 10 −8 mol L −1 at a signal-to-noise ratio of 3

  6. Investigation on Aerodynamic Noise Evaluation and Attenuation In a Globe Valve using CFD Analysis

    Directory of Open Access Journals (Sweden)

    S K Sreekala

    2016-03-01

    Full Text Available Noise pollution will soon become the third greatest menace to the human environment after air and water pollution. Since noise is a by-product of energy conversion, there will be increasing noise as the demand for energy for transportation, power, food, and chemicals increases. In the field of control equipment, noise produced by valves has become a focal point of attention .In this paper aerodynamic noise evaluation of a globe valve was carried out  using a three dimensional Computational Fluid Dynamic technique(CFD. The results obtained from numerical analysis are compared with the experimental measurements and are found   to be in good agreement. Reduction in sound pressure level was achieved by doubling the number of flow passages in the cage at full open condition and at the same operating conditions. Hence sound attenuation is established by changing the cage configuration with no change in total area of flow passage in the cage

  7. Investigation of Diesel’s Residual Noise on Predictive Vehicles Noise Cancelling using LMS Adaptive Algorithm

    Science.gov (United States)

    Arttini Dwi Prasetyowati, Sri; Susanto, Adhi; Widihastuti, Ida

    2017-04-01

    Every noise problems require different solution. In this research, the noise that must be cancelled comes from roadway. Least Mean Square (LMS) adaptive is one of the algorithm that can be used to cancel that noise. Residual noise always appears and could not be erased completely. This research aims to know the characteristic of residual noise from vehicle’s noise and analysis so that it is no longer appearing as a problem. LMS algorithm was used to predict the vehicle’s noise and minimize the error. The distribution of the residual noise could be observed to determine the specificity of the residual noise. The statistic of the residual noise close to normal distribution with = 0,0435, = 1,13 and the autocorrelation of the residual noise forming impulse. As a conclusion the residual noise is insignificant.

  8. Aerobic and Electrochemical Oxidations with N-Oxyl Reagents

    Science.gov (United States)

    Miles, Kelsey C.

    Selective oxidation of organic compounds represents a significant challenge for chemical transformations. Oxidation methods that utilize nitroxyl catalysts have become increasingly attractive and include Cu/nitroxyl and nitroxyl/NO x co-catalyst systems. Electrochemical activation of nitroxyls is also well known and offers an appealing alternative to the use of chemical co-oxidants. However, academic and industrial organic synthetic communities have not widely adopted electrochemical methods. Nitroxyl catalysts facilitate effective and selective oxidation of alcohols and aldehydes to ketones and carboxylic acids. Selective benzylic, allylic, and alpha-heteroatom C-H abstraction can also be achieved with nitroxyls and provides access to oxygenated products when used in combination with molecular oxygen as a radical trap. This thesis reports various chemical and electrochemical oxidation methods that were developed using nitroxyl mediators. Chapter 1 provides a short review on practical aerobic alcohol oxidation with Cu/nitroxyl and nitroxyl/NO x systems and emphasizes the utility of bicyclic nitroxyls as co-catalysts. In Chapter 2, the combination of these bicyclic nitroxyls with NOx is explored for development of a mild oxidation of alpha-chiral aryl aldehydes and showcases a sequential asymmetric hydroformylation/oxidation method. Chapter 3 reports the synthesis and characterization of two novel Cu/bicyclic nitroxyl complexes and the electronic structure analysis of these complexes. Chapter 4 highlights the electrochemical activation of various nitroxyls and reports an in-depth study on electrochemical alcohol oxidation and compares the reactivity of nitroxyls under electrochemical or chemical activation. N-oxyls can also participate in selective C-H abstraction, and Chapter 5 reports the chemical and electrochemical activation of N-oxyls for radical-mediated C-H oxygenation of (hetero)arylmethanes. For these electrochemical transformations, the development of

  9. Understanding of electrochemical and structural changes of polypyrrole/polyethylene glycol composite films in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Pirvu, Cristian, E-mail: c_pirvu@chim.pub.ro [University Polytechnic of Bucharest, Faculty of Applied Chemistry and Materials Science, 1-7 Polizu, 011061 Bucharest (Romania); Manole, Claudiu Constantin; Stoian, Andrei Bogdan; Demetrescu, Ioana [University Polytechnic of Bucharest, Faculty of Applied Chemistry and Materials Science, 1-7 Polizu, 011061 Bucharest (Romania)

    2011-11-30

    Highlights: > Electrochemical monitoring of PPy and PPy-PEG films over immersion time. > Electrochemical and surface analysis showed that PEG improves the stability of PPy films. > Mott-Schottky analysis reveals p-type conductance for both films. > In situ AFM analysis sustains electrochemical behaviour. > A model of PPy and PPy-PEG films behaviour during immersion was elaborated. - Abstract: Electrochemical monitoring of electrical and structural changes of both PPy and PPy-PEG films electrochemical deposited, in order to highlight if the structural stability offered by PEG has an influence on electrical properties and stability in aqueous solution over immersion time was investigated. Electrochemical analysis suggests that PPy-PEG film inserts cations easier than PPy film for a short immersion time probably due to ability of PEG to form complexes with metal cations. The FTIR spectra showed that the PEG incorporation decreases the rate of PPy overoxidation probably by restraining the electron release and by rendering O{sub 2} inaccessible to PPy. Mott-Schottky analysis based on capacitance measurement reveal p-type conductance for both films. The in situ AFM analysis sustains electrochemical behaviour and has permitted elaboration of a model of PPy and PPy-PEG films behaviour during immersion in testing solution.

  10. Electrochemical Study of Delta-9-Tetrahydrocannabinol by Cyclic Voltammetry Using Screen Printed Electrode, Improvements in Forensic Analysis

    Directory of Open Access Journals (Sweden)

    Marco Antonio BALBINO

    2016-12-01

    Full Text Available Rapid screening of seized drugs is a continuing problem for governmental laboratories and customs agents. Recently new and cheaper methods based on electrochemical sensing have been developed for the detection of illicit drugs. Screen printed electrodes are particularly useful in this regard and can provide excellent sensitivity. In this study, a carbon screen printed electrode for the voltammetric analysis of D9-THC was developed. The analysis was performed using cyclic voltammetry with 0.15 mol×L-1 potassium nitrate as a supporting electrolyte. In the analysis, a D9-THC standard solution was added to the surface electrode by a drop coating method. A study of scan rate, time of pre-concentration, and concentration influence parameters showed versatility during the investigation. The high sensitivity, quantitative capability and low limit of detection (1.0 µmol×L-1 demonstrate that this electrochemical method should be an attractive alternative in forensic investigations of seized samples.

  11. Damping layout optimization for ship's cabin noise reduction based on statistical energy analysis

    Directory of Open Access Journals (Sweden)

    WU Weiguo

    2017-08-01

    Full Text Available An optimization analysis study concerning the damping control of ship's cabin noise was carried out in order to improve the effect and reduce the weight of damping. Based on the Statistical Energy Analysis (SEA method, a theoretical deduction and numerical analysis of the first-order sensitivity analysis of the A-weighted sound pressure level concerning the damping loss factor of the subsystem were carried out. On this basis, a mathematical optimization model was proposed and an optimization program developed. Next, the secondary development of VA One software was implemented through the use of MATLAB, while the cabin noise damping control layout optimization system was established. Finally, the optimization model of the ship was constructed and numerical experiments of damping control optimization conducted. The damping installation region was divided into five parts with different damping thicknesses. The total weight of damping was set as an objective function and the A-weighted sound pressure level of the target cabin was set as a constraint condition. The best damping thickness was obtained through the optimization program, and the total damping weight was reduced by 60.4%. The results show that the damping noise reduction effect of unit weight is significantly improved through the optimization method. This research successfully solves the installation position and thickness selection problems in the acoustic design of damping control, providing a reliable analysis method and guidance for the design.

  12. Monitoring and diagnosis in situ: noise analysis; Vigilancia y diagnostico in situ analisis de ruido

    Energy Technology Data Exchange (ETDEWEB)

    Montalvo, C.; Garcia-Berrocal, A.

    2014-04-01

    Predictive maintenance based on surveillance and breakdowns diagnostics can be achieved through the analysis of the noise hidden in the signals. At the beginning noise analysis was development to monitor the power signals coming from neutron detectors. Nowadays its applications are very diverse. For instance: process sensors surveillance such us Resistance Temperature detectors, thermocouples and pressure transmitters, internals vibration monitoring, abnormal vibrations detection, etc. In this work some examples from the literature and from the authors experience are presented. (Author)

  13. A 0.18 μm biosensor front-end based on 1/f noise, distortion cancelation and chopper stabilization techniques.

    Science.gov (United States)

    Balasubramanian, Viswanathan; Ruedi, Pierre-Francois; Temiz, Yuksel; Ferretti, Anna; Guiducci, Carlotta; Enz

    2013-10-01

    This paper presents a novel sensor front-end circuit that addresses the issues of 1/f noise and distortion in a unique way by using canceling techniques. The proposed front-end is a fully differential transimpedance amplifier (TIA) targeted for current mode electrochemical biosensing applications. In this paper, we discuss the architecture of this canceling based front-end and the optimization methods followed for achieving low noise, low distortion performance at minimum current consumption are presented. To validate the employed canceling based front-end, it has been realized in a 0.18 μm CMOS process and the characterization results are presented. The front-end has also been tested as part of a complete wireless sensing system and the cyclic voltammetry (CV) test results from electrochemical sensors are provided. Overall current consumption in the front-end is 50 μA while operating on a 1.8 V supply.

  14. Analysis of electrochemical disintegration process of graphite matrix

    International Nuclear Information System (INIS)

    Tian Lifang; Wen Mingfen; Chen Jing

    2010-01-01

    The electrochemical method with ammonium nitrate as electrolyte was studied to disintegrate the graphite matrix from the simulative fuel elements for high temperature gas-cooled reactor. The influences of process parameters, including salt concentration, system temperature and current density, on the disintegration rate of graphite fragments were investigated in the present work. The experimental results showed that the disintegration rate depended slightly on the temperature and salt concentration. The current density strongly affected the disintegration rate of graphite fragments. Furthermore, the content of introduced oxygen in final graphite fragments was independent of the current density and the concentration of electrolyte. Moreover, the structural evolution of graphite was analyzed based on the microstructural parameters determined by X-ray diffraction profile fitting analysis using MAUD (material analysis using diffraction) before and after the disintegration process. It may safely be concluded that the graphite disintegration can be ascribed to the influences of the intercalation of foreign molecules in between crystal planes and the partial oxidation involved. The disintegration process was described deeply composed of intercalate part and further oxidation part of carbon which effected together to lead to the collapse of graphite crystals.

  15. Electrochemical and genomic analysis of novel electroactive isolates obtained via potentiostatic enrichment from tropical sediment

    Science.gov (United States)

    Doyle, Lucinda E.; Yung, Pui Yi; Mitra, Sumitra D.; Wuertz, Stefan; Williams, Rohan B. H.; Lauro, Federico M.; Marsili, Enrico

    2017-07-01

    Enrichment of electrochemically-active microorganisms (EAM) to date has mostly relied on microbial fuel cells fed with wastewater. This study aims to enrich novel EAM by exposing tropical sediment, not frequently reported in the literature, to sustained anodic potentials. Voltamperometric techniques and electrochemical impedance spectroscopy, performed over a wide range of potentials, characterise extracellular electron transfer (EET) over time. Applied potential is found to affect biofilm electrochemical signature. Geobacter metallireducens is heavily enriched on the electrodes, as determined by metagenomic and metatranscriptomic analysis, in the first report of the species in a lactate-fed system. Two novel isolates are grown in pure culture from the enrichment, identified by 16S rRNA gene sequencing as Aeromonas and Enterobacter, respectively. The names proposed are Aeromonas sp. CL-1 and Enterobacter sp. EA-1. Both isolates are capable of EET on carbon felt and screen-printed carbon electrodes without the addition of exogenous redox mediators. Enterobacter sp. EA-1 can also perform mediated electron transfer using the soluble redox mediator 2-hydroxy-1,4-naphthoquinone (HNQ). Both isolates are able to use acetate and lactate as electron donors. This work outlines a comprehensive methodology for characterising novel EAM from unconventional inocula.

  16. On minimizing the influence of the noise tail of correlation functions in operational modal analysis

    DEFF Research Database (Denmark)

    Tarpø, Marius; Olsen, Peter; Amador, Sandro

    2017-01-01

    on the identification results (random errors) when the noise tail is included in the identification. On the other hand, if the correlation function is truncated too much, then important information is lost. In other to minimize this error, a suitable truncation based on manual inspection of the correlation function......In operational modal analysis (OMA) correlation functions are used by all classical time-domain modal identification techniques that uses the impulse response function (free decays) as primary data. However, the main difference between the impulse response and the correlation functions estimated...... from the operational responses is that the latter present a higher noise level. This is due to statistical errors in the estimation of the correlation function and it causes random noise in the end of the function and this is called the noise tail. This noise might have significant influence...

  17. Antigen-antibody biorecognition events as discriminated by noise analysis of force spectroscopy curves.

    Science.gov (United States)

    Bizzarri, Anna Rita; Cannistraro, Salvatore

    2014-08-22

    Atomic force spectroscopy is able to extract kinetic and thermodynamic parameters of biomolecular complexes provided that the registered unbinding force curves could be reliably attributed to the rupture of the specific complex interactions. To this aim, a commonly used strategy is based on the analysis of the stretching features of polymeric linkers which are suitably introduced in the biomolecule-substrate immobilization procedure. Alternatively, we present a method to select force curves corresponding to specific biorecognition events, which relies on a careful analysis of the force fluctuations of the biomolecule-functionalized cantilever tip during its approach to the partner molecules immobilized on a substrate. In the low frequency region, a characteristic 1/f (α) noise with α equal to one (flickering noise) is found to replace white noise in the cantilever fluctuation power spectrum when, and only when, a specific biorecognition process between the partners occurs. The method, which has been validated on a well-characterized antigen-antibody complex, represents a fast, yet reliable alternative to the use of linkers which may involve additional surface chemistry and reproducibility concerns.

  18. Process sensors characterization based on noise analysis technique and artificial intelligence

    International Nuclear Information System (INIS)

    Mesquita, Roberto N. de; Perillo, Sergio R.P.; Santos, Roberto C. dos

    2005-01-01

    The time response of pressure and temperature sensors from the Reactor Protection System (RPS) is a requirement that must be satisfied in nuclear power plants, furthermore is an indicative of its degradation and its remaining life. The nuclear power industry and others have been eager to implement smart sensor technologies and digital instrumentation concepts to reduce manpower and effort currently spent on testing and calibration. Process parameters fluctuations during normal operation of a reactor are caused by random variations in neutron flux, heat transfer and other sources. The output sensor noise can be considered as the response of the system to an input representing the statistical nature of the underlying process which can be modeled using a time series model. Since the noise signal measurements are influenced by many factors, such as location of sensors, extraneous noise interference, and randomness in temperature and pressure fluctuation - the quantitative estimate of the time response using autoregressive noise modeling is subject to error. This technique has been used as means of sensor monitoring. In this work a set of pressure sensors installed in one experimental loop adapted from a flow calibration setup is used to test and analyze signals in a new approach using artificial intelligence techniques. A set of measurements of dynamic signals in different experimental conditions is used to distinguish and identify underlying process sources. A methodology that uses Blind Separation of Sources with a neural networks scheme is being developed to improve time response estimate reliability in noise analysis. (author)

  19. Process sensors characterization based on noise analysis technique and artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Roberto N. de; Perillo, Sergio R.P.; Santos, Roberto C. dos [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rnavarro@ipen.br; sperillo@ipen.br; rcsantos@ipen.br

    2005-07-01

    The time response of pressure and temperature sensors from the Reactor Protection System (RPS) is a requirement that must be satisfied in nuclear power plants, furthermore is an indicative of its degradation and its remaining life. The nuclear power industry and others have been eager to implement smart sensor technologies and digital instrumentation concepts to reduce manpower and effort currently spent on testing and calibration. Process parameters fluctuations during normal operation of a reactor are caused by random variations in neutron flux, heat transfer and other sources. The output sensor noise can be considered as the response of the system to an input representing the statistical nature of the underlying process which can be modeled using a time series model. Since the noise signal measurements are influenced by many factors, such as location of sensors, extraneous noise interference, and randomness in temperature and pressure fluctuation - the quantitative estimate of the time response using autoregressive noise modeling is subject to error. This technique has been used as means of sensor monitoring. In this work a set of pressure sensors installed in one experimental loop adapted from a flow calibration setup is used to test and analyze signals in a new approach using artificial intelligence techniques. A set of measurements of dynamic signals in different experimental conditions is used to distinguish and identify underlying process sources. A methodology that uses Blind Separation of Sources with a neural networks scheme is being developed to improve time response estimate reliability in noise analysis. (author)

  20. BAYESIAN ANALYSIS OF WHITE NOISE LEVELS IN THE FIVE-YEAR WMAP DATA

    International Nuclear Information System (INIS)

    Groeneboom, N. E.; Eriksen, H. K.; Gorski, K.; Huey, G.; Jewell, J.; Wandelt, B.

    2009-01-01

    We develop a new Bayesian method for estimating white noise levels in CMB sky maps, and apply this algorithm to the five-year Wilkinson Microwave Anisotropy Probe (WMAP) data. We assume that the amplitude of the noise rms is scaled by a constant value, α, relative to a pre-specified noise level. We then derive the corresponding conditional density, P(α | s, C l , d), which is subsequently integrated into a general CMB Gibbs sampler. We first verify our code by analyzing simulated data sets, and then apply the framework to the WMAP data. For the foreground-reduced five-year WMAP sky maps and the nominal noise levels initially provided in the five-year data release, we find that the posterior means typically range between α = 1.005 ± 0.001 and α = 1.010 ± 0.001 depending on differencing assembly, indicating that the noise level of these maps are biased low by 0.5%-1.0%. The same problem is not observed for the uncorrected WMAP sky maps. After the preprint version of this letter appeared on astro-ph., the WMAP team has corrected the values presented on their web page, noting that the initially provided values were in fact estimates from the three-year data release, not from the five-year estimates. However, internally in their five-year analysis the correct noise values were used, and no cosmological results are therefore compromised by this error. Thus, our method has already been demonstrated in practice to be both useful and accurate.

  1. Comparative analysis of chosen transforms in the context of de-noising harmonic signals

    Directory of Open Access Journals (Sweden)

    Artur Zacniewski

    2015-09-01

    Full Text Available In the article, comparison of popular transforms used i.a. in denoising harmonical signals was presented. The division of signals submitted to mathematical analysis was shown and chosen transforms such as Short Time Fourier Transform, Wigner-Ville Distribution, Wavelet Transform and Discrete Cosine Transform were presented. Harmonic signal with white noise added was submitted for research. During research, the parameters of noise were changed to analyze the effects of using particular transform on noised signal. The importance of right choice for transform and its parameters (different for particular kind of transform was shown. Small changes in parameters or different functions used in transform can lead to considerably different results.[b]Keywords[/b]: denoising of harmonical signals, wavelet transform, discrete cosine transform, DCT

  2. Spectral data de-noising using semi-classical signal analysis: application to localized MRS

    KAUST Repository

    Laleg-Kirati, Taous-Meriem

    2016-09-05

    In this paper, we propose a new post-processing technique called semi-classical signal analysis (SCSA) for MRS data de-noising. Similar to Fourier transformation, SCSA decomposes the input real positive MR spectrum into a set of linear combinations of squared eigenfunctions equivalently represented by localized functions with shape derived from the potential function of the Schrodinger operator. In this manner, the MRS spectral peaks represented as a sum of these \\'shaped like\\' functions are efficiently separated from noise and accurately analyzed. The performance of the method is tested by analyzing simulated and real MRS data. The results obtained demonstrate that the SCSA method is highly efficient in localized MRS data de-noising and allows for an accurate data quantification.

  3. Spectral data de-noising using semi-classical signal analysis: application to localized MRS

    KAUST Repository

    Laleg-Kirati, Taous-Meriem; Zhang, Jiayu; Achten, Eric; Serrai, Hacene

    2016-01-01

    In this paper, we propose a new post-processing technique called semi-classical signal analysis (SCSA) for MRS data de-noising. Similar to Fourier transformation, SCSA decomposes the input real positive MR spectrum into a set of linear combinations of squared eigenfunctions equivalently represented by localized functions with shape derived from the potential function of the Schrodinger operator. In this manner, the MRS spectral peaks represented as a sum of these 'shaped like' functions are efficiently separated from noise and accurately analyzed. The performance of the method is tested by analyzing simulated and real MRS data. The results obtained demonstrate that the SCSA method is highly efficient in localized MRS data de-noising and allows for an accurate data quantification.

  4. Predetermining acceptable noise limits of EXAFS spectra in the limit of stochastic noise

    International Nuclear Information System (INIS)

    Hu, Yung-Jin; Booth, Corwin H

    2009-01-01

    The effect of stochastic noise on Extended X-ray Absorption Fine Structure (EXAFS) data measurement, analysis, and fitting is discussed. Stochastic noise reduces the ability to uniquely fit a calculated model to measured EXAFS data. Such noise can be reduced by common methods that increase the signal-to-noise ratio; however, these methods are not always practical. Therefore, predetermined, quantitative knowledge of the level of acceptable stochastic noise when fitting for a particular model system is essential in maximizing the chances of a successful EXAFS experiment and minimizing wasted beamtime. This paper outlines a method to estimate, through simulation, the acceptable level of stochastic noise in EXAFS spectra that still allows a successful test of a proposed model compound.

  5. Noise Reduction Effect of Multiple-Sampling-Based Signal-Readout Circuits for Ultra-Low Noise CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Shoji Kawahito

    2016-11-01

    Full Text Available This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs. This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC. The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median: 0.29 e−rms when compared with the CMS gain of two (2.4 e−rms, or 16 (1.1 e−rms.

  6. High temperature and pressure electrochemical test station

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Allebrod, Frank; Mogensen, Mogens Bjerg

    2013-01-01

    An electrochemical test station capable of operating at pressures up to 100 bars and temperatures up to 400 ◦C has been established. It enables control of the partial pressures and mass flow of O2, N2, H2, CO2, and H2O in a single or dual environment arrangement, measurements with highly corrosive...... media, as well as localized sampling of gas evolved at the electrodes for gas analysis. A number of safety and engineering design challenges have been addressed. Furthermore, we present a series of electrochemical cell holders that have been constructed in order to accommodate different types of cells...... and facilitate different types of electrochemical measurements. Selected examples of materials and electrochemical cells examined in the test station are provided, ranging from the evaluation of the ionic conductivity of liquid electrolytic solutions immobilized in mesoporous ceramic structures...

  7. Background noise analysis in urban airport surroundings of Brazilian cities, Congonhas Airport, São Paulo

    Directory of Open Access Journals (Sweden)

    Fabio Scatolini

    Full Text Available ABSTRACT OBJECTIVE To perform a quantitative analysis of the background noise at Congonhas Airport surroundings based on large sampling and measurements with no interruption. METHODS Measuring sites were chosen from 62 and 72 DNL (day-night-level noise contours, in urban sites compatible with residential use. Fifteen sites were monitored for at least 168 hours without interruption or seven consecutive days. Data compilation was based on cross-reference between noise measurements and air traffic control records, and results were validated by airport meteorological reports. Preliminary diagnoses were established using the standard NBR-13368. Background noise values were calculated based on the Sound Exposure Level (SEL. Statistic parameters were calculated in one-hour intervals. RESULTS Only four of the fifteen sites assessed presented aircraft operations as a clear cause for the noise annoyance. Even so, it is possible to detect background noise levels above regulation limits during periods of low airport activity or when it closes at night. CONCLUSIONS All the sites monitored showed background noise levels above regulation limits between 7:00 and 21:00. In the intervals between 6:00-6:59 and 21:00-22:59 the noise data, when analyzed with the current airport operational characteristics, still allow the development of additional mitigating measures.

  8. Distributed system for acquisition and analysis of NPP systems noise data

    International Nuclear Information System (INIS)

    Oprea, F.; Gruia, L.

    2001-01-01

    Since years '90 the noise analysis for nuclear stations is more frequently used because: - the data can be acquired by making use of the NPP instrumentation; - acquisition may be performed in a steady-state regime, at rated capacity; - reactor dynamical regime data are obtainable although steady-state regime data are used. The signal noise analysis is based on the dynamical information about the reactor operation obtained from instrumentation signal fluctuations as determined in steady-system regime. The small fluctuations are due to the stochastic effects inherent to physical processes such as heat transfer, boiling, turbulences in coolant flow, moderator collective motions, fission process, structural vibrations and pressure oscillations. Specifically, for CANDU type reactors, the results may be applied for: - surveillance of the functioning characteristics of detectors and transducers; - signaling or predicting misfunctioning of detectors and transducers, what implies establishment of optimal time rate for macro-sampling; - signaling or prediction of misfunctioning of reactor core components, what implies setting up methods and procedures for detecting vibrations inside the fuel channels, based mainly on the signals from the ROPT adjacent detectors and on the flow rate transducers. The system of signal acquisition is a distributed, fixed-data acquisition system provided with a limited number of inputs, based on a number of modules of local analog signal processing and conversion to digital representation. The signal, local processing implies noise removal out of signal through continuous current component elimination, an amplification of the signal, low-pass filtering for alias frequency removal, 16 bit analog-to-digital conversion and digital value serial way transmission. The local processing is based on the characteristics of the acquired signal (noise), namely: - the frequency band, 0.01 Hz - 200 Hz; - the signal amplitude level, 16 - 32 MeV superimposed

  9. Structural and electrochemical analysis of chemically synthesized microcubic architectured lead selenide thin films

    Science.gov (United States)

    Bhat, T. S.; Shinde, A. V.; Devan, R. S.; Teli, A. M.; Ma, Y. R.; Kim, J. H.; Patil, P. S.

    2018-01-01

    The present work deals with the synthesis of lead selenide (PbSe) thin films by simple and cost-effective chemical bath deposition method with variation in deposition time. The structural, morphological, and electrochemical properties of as-deposited thin films were examined using characterization techniques such as X-ray diffraction spectroscopy (XRD), field-emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV), galvanostatic charge-discharge and electrochemical impedance spectroscopy. XRD reveals formation of rock salt phase cubic structured PbSe. FE-SEM images show the formation of microcubic structured morphology. The existence of the PbSe is confirmed from the XPS analysis. On the other hand, CV curves show four reaction peaks corresponding to oxidation [PbSe and Pb(OH)2] and reduction (PbO2 and Pb(OH)2) at the surface of PbSe thin films. The PbSe:2 sample deposited for 80 min. shows maximum specific capacitance of 454 ± 5 F g- 1 obtained at 0.25 mA cm- 2 current density. The maximum energy density of 69 Wh kg- 1 was showed by PbSe:2 electrode with a power density of 1077 W kg- 1. Furthermore, electrochemical impedance studies of PbSe:2 thin film show 80 ± 3% cycling stability even after 500 CV cycles. Such results show the importance of microcubic structured PbSe thin film as an anode in supercapacitor devices.

  10. Market Analysis of Soundproof and Noise Reduction Plate

    Directory of Open Access Journals (Sweden)

    Chang Heyu

    2017-01-01

    Full Text Available Since the reform and opening up, China has a booming economy development, transportation industry as an important part of the economic processes has made a considerable progress, and continue to promote the rapid economic development. At the end of 2012, China's highway mileage has reached 4.238 million km and highway mileage ranks first in the world. Transportation in promoting rapid economic development, but also brings the traffic noise which has a tremendous influence on residents’ daily life, and this influence has gradually deepening and widening, in this situation the production of noise reduction panel gradually emerged. In this paper, a noise barriers manufacturer’ business model in Beijing Daxing District and analyze existing data will be analyzed, it will give much guidance and reference for a new noise reduction factory. The study has shown that plant will target all levels of government departments in charge of roads and the property of management department of residence as our customer groups, increasing technological innovation and improving product quality to establish a more extensive business relationships, and gradually formed noise barriers market competitiveness.

  11. Development of miniaturized disposable electrochemical systems intended for point of care blood analysis

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel

    to pH changes in a very reproducible way despite their very simple fabrication processes. Moreover, the developed voltammetric system presented the major advantage of limiting the potential issues stemming from the reference half-cell. Indeed, since the measurement principle was based on evaluating...... that significant differences in terms of electrochemical, mechanical and electrical properties exist between these products. The effect of electrochemical and thermal treatments of the screen-printed materials was also investigated. This study resulted in the selection of an optimal electrochemical system used...... species. Moreover, to my knowledge, the use of SP for the development of this type of voltammetric systems has surprisingly only been recently investigated by D. K. Kampouris et al. [1] despite its undeniable advantages. Electrochemical measurements highlighted the promising performances...

  12. Understanding of electrochemical and structural changes of polypyrrole/polyethylene glycol composite films in aqueous solution

    International Nuclear Information System (INIS)

    Pirvu, Cristian; Manole, Claudiu Constantin; Stoian, Andrei Bogdan; Demetrescu, Ioana

    2011-01-01

    Highlights: → Electrochemical monitoring of PPy and PPy-PEG films over immersion time. → Electrochemical and surface analysis showed that PEG improves the stability of PPy films. → Mott-Schottky analysis reveals p-type conductance for both films. → In situ AFM analysis sustains electrochemical behaviour. → A model of PPy and PPy-PEG films behaviour during immersion was elaborated. - Abstract: Electrochemical monitoring of electrical and structural changes of both PPy and PPy-PEG films electrochemical deposited, in order to highlight if the structural stability offered by PEG has an influence on electrical properties and stability in aqueous solution over immersion time was investigated. Electrochemical analysis suggests that PPy-PEG film inserts cations easier than PPy film for a short immersion time probably due to ability of PEG to form complexes with metal cations. The FTIR spectra showed that the PEG incorporation decreases the rate of PPy overoxidation probably by restraining the electron release and by rendering O 2 inaccessible to PPy. Mott-Schottky analysis based on capacitance measurement reveal p-type conductance for both films. The in situ AFM analysis sustains electrochemical behaviour and has permitted elaboration of a model of PPy and PPy-PEG films behaviour during immersion in testing solution.

  13. Non-Enzymatic Wearable Sensor for Electrochemical Analysis of Perspiration Glucose.

    Science.gov (United States)

    Zhu, Xiaofei; Ju, Yinhui; Chen, Jian; Liu, Deye; Liu, Hong

    2018-05-16

    We report a non-enzymatic wearable sensor for electrochemical analysis of perspiration glucose. Multi-potential steps are applied on a Au electrode, including a high negative pretreatment potential step for proton reduction which produc-es a localized alkaline condition, a moderate potential step for electrocatalytic oxidation of glucose under the alkaline condi-tion, and a positive potential step to clean and reactivate the electrode surface for the next detection. Fluorocarbon-based materials were coated on the Au electrode for improving the selectivity and robustness of the sensor. A fully integrated wrist-band is developed for continuous real-time monitoring of perspiration glucose during physical activities, and uploading the test result to a Smartphone App via Bluetooth.

  14. Neutron activation analysis of uranium by means of electrochemical etching of tracks in lawsan detectors

    International Nuclear Information System (INIS)

    Kim Son Chun; Chuburkov, Yu.T.; Zvara, I.I.

    1982-01-01

    The method of neutron activation analysis of uranium in natural and artificial materials using track lavsan detectors of fission fragments has been developed. The method of electrochemical etching (etching reagent NaOH) of fragment tracks in lavsan is improved. Using statistical method of experiment planning the equation, describing the dependence of diometer value of fission fragment tracks on parameters of etching process, is obtained. The analysis sensitivity is 10 - 7 g/g - 10 - 8 g/g

  15. Multichannel Bipotentiostat Integrated With a Microfluidic Platform for Electrochemical Real-Time Monitoring of Cell Cultures

    DEFF Research Database (Denmark)

    Vergani, Marco; Carminati, Marco; Ferrari, Giorgio

    2012-01-01

    An electrochemical detection system specifically designed for multi-parameter real-time monitoring of stem cell culturing/differentiation in a microfluidic system is presented. It is composed of a very compact 24-channel electronic board, compatible with arrays of microelectrodes and coupled...... to a microfluidic cell culture system. A versatile data acquisition software enables performing amperometry, cyclic voltammetry and impedance spectroscopy in each of the 12 independent chambers over a 100 kHz bandwidth with current resolution down to 5 pA for 100 ms measuring time. The design of the platform, its...... realization and experimental characterization are reported, with emphasis on the analysis of impact of input capacitance (i.e., microelectrode size) and microfluidic pump operation on current noise. Programmable sequences of successive injections of analytes (ferricyanide and dopamine) and rinsing buffer...

  16. An electrochemical sensor based on carboxymethylated dextran modified gold surface for ochratoxin A analysis

    OpenAIRE

    Heurich, Meike; Kadir, Mohamad Kamal Abdul; Tothill, Ibtisam E.

    2011-01-01

    A disposable electrochemical immunosensor method was developed for ochratoxin A analysis to be applied for wine samples by using a screen-printed gold working electrode with carbon counter and silver/silver chloride pseudo-reference electrode. An indirect competitive enzyme-linked immunosorbent assay (ELISA) format was constructed by immobilising ochratoxin A conjugate using passive adsorption or covalent immobilisation via amine coupling to a carboxymethylated dextran (CMD)...

  17. Electrochemical biosensors

    CERN Document Server

    Cosnier, Serge

    2015-01-01

    "This is an excellent book on modern electrochemical biosensors, edited by Professor Cosnier and written by leading international experts. It covers state-of-the-art topics of this important field in a clear and timely manner."-Prof. Joseph Wang, UC San Diego, USA  "This book covers, in 13 well-illustrated chapters, the potential of electrochemical methods intimately combined with a biological component for the assay of various analytes of biological and environmental interest. Particular attention is devoted to the description of electrochemical microtools in close contact with a biological cell for exocytosis monitoring and to the use of nanomaterials in the electrochemical biosensor architecture for signal improvement. Interestingly, one chapter describes the concept and design of self-powered biosensors derived from biofuel cells. Each topic is reviewed by experts very active in the field. This timely book is well suited for providing a good overview of current research trends devoted to electrochemical...

  18. Analysis of power tiller noise using diesel-biodiesel fuel blends

    Directory of Open Access Journals (Sweden)

    N Keramat Siavash

    2015-09-01

    , capacitor microphone with a unidirectional pattern whose size, sensitivity and frequency range are 1/2", 50 mV Pa-1 and 10 Hz to 20 kHz with a flat extrusion, respectively. Choosing the combination of fuel was carried out according to experiments that have been done before determining engine operation parameters. Results and Discussion: Fuel type has a direct effect on the quality of the IC engine's combustion phenomenon. One of the most important quality parameters that can be fluctuated by fuel type is engine noise. The fuel type has a direct effect on internal fuel ignition engines and affects the quality of fuel ignition. One of the effects of ignition quality is the sound of the engine that is very important in terms of both the health and evaluation of engine performance. Two-wheel tractors are of the most important tools used in agriculture. In addition to agricultural work, they have applications in rural areas as power generators. No research has been carried out so far in Iran on the sound of two-wheel tractors fuelled with diesel and biodiesel fuels. Therefore, the sound of the ignition of biodiesel and diesel mixtures in four stroke, single cylinder, two wheel diesel tractors manufactured by Ashtad Company was studied. The purpose of this study is to analyze the noise parameters of a diesel engine using B0, B5, B10, B15, B20, B25 and B30 biodiesel–diesel blends. Biodiesel was produced from waste oil and blended with net diesel fuel to evaluate the Power tiller's engine noise parameters. This study was carried out at a stationary position and at three positions such as driver's left ear position (DLEP, 1.5 meter (1.5 MAFE and 7.5 meters (7.5 MAFE away from the exhaust at 6 engine speeds (1200, 1400, 1600, 1800, 2000 & 2200 rpm. Statistical analysis and frequency analysis were used to analyze sound of the engine. The results showed that the sound pressure levels of the engine for B10 fuel have the least amount of noise level of the sound pressure. However, this

  19. OPTIMAL AUTOMOBILE MUFFLER VIBRATION AND NOISE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Sujit Kumar Jha

    2013-06-01

    Full Text Available The muffler is the main part of the Automobile Exhaust System, consisting of fibrous and porous materials to absorb noise and vibrations. The exhaust gas mass coming from the engine can produce resonance, which may be the source of fatigue failure in the exhaust pipe due to the presence of continuous resonance. The modes on the muffler should be located away from the engine’s operating frequencies in order to minimise the resonance. The objective of this paper is to determine the frequencies that appear at the modes, which have the more adverse effect during the operation of the automobile. An impact test has been conducted by applying the force using a hard head hammer, and data generated have been used for plotting a graph of the transfer functions using MATLAB. Six points have been selected, namely 1, 2, 3, 4, 7, and 11 on the muffler for the impact test. The collected data from theses six points have been analysed for the addition of damping. Results suggests that increasing the mass increases the damping and lowers the modes of the transfer function. Further research will identify higher strength materials that can withstand the higher gas temperatures as well as the corrosion and erosion by the gas emitted from the engine. muffler, noise, vibration,modal analysis,

  20. An ultrasensitive electrochemical DNA biosensor based on a copper oxide nanowires/single-walled carbon nanotubes nanocomposite

    International Nuclear Information System (INIS)

    Chen, Mei; Hou, Changjun; Huo, Danqun; Yang, Mei; Fa, Huanbao

    2016-01-01

    Graphical abstract: A novel and sensitive electrochemical biosensor based on hybrid nanocomposite consisting of copper oxide nanowires (CuO NWs) and carboxyl-functionalized single-walled carbon nanotubes (SWCNTs-COOH) was first developed for the detection of the specific-sequence target DNA. This schematic represents the fabrication procedure of our DNA biosensor. - Highlights: • An ultrasensitive DNA electrochemical biosensor was developed. • CuO NWs entangled with the SWCNTs formed a mesh structure with good conductivity. • It is the first time use of CuONWs-SWCNTs hybrid nanocomposite for DNA detection. • The biosensor is simple, selective, stable, and sensitive. • The biosensor has great potential for use in analysis of real samples. - Abstract: Here, we developed a novel and sensitive electrochemical biosensor to detect specific-sequence target DNA. The biosensor was based on a hybrid nanocomposite consisting of copper oxide nanowires (CuO NWs) and carboxyl-functionalized single-walled carbon nanotubes (SWCNTs-COOH). The resulting CuO NWs/SWCNTs layers exhibited a good differential pulse voltammetry (DPV) current response for the target DNA sequences, which we attributed to the properties of CuO NWs and SWCNTs. CuO NWs and SWCNTs hybrid composites with highly conductive and biocompatible nanostructure were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), and cyclic voltammetry (CV). Immobilization of the probe DNA on the electrode surface was largely improved due to the unique synergetic effect of CuO NWs and SWCNTs. DPV was applied to monitor the DNA hybridization event, using adriamycin as an electrochemical indicator. Under optimal conditions, the peak currents of adriamycin were linear with the logarithm of target DNA concentrations (ranging from 1.0 × 10"−"1"4 to 1.0 × 10"−"8 M), with a detection limit of 3.5 × 10"−"1"5 M (signal/noise ratio of 3). The biosensor also showed high selectivity to

  1. An ultrasensitive electrochemical DNA biosensor based on a copper oxide nanowires/single-walled carbon nanotubes nanocomposite

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Mei [Key Laboratory of Biorheology Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044 (China); Hou, Changjun, E-mail: houcj@cqu.edu.cn [Key Laboratory of Biorheology Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044 (China); National Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, Chongqing University, Chongqing 400044 (China); Huo, Danqun [Key Laboratory of Biorheology Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044 (China); National Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, Chongqing University, Chongqing 400044 (China); Yang, Mei [Key Laboratory of Biorheology Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044 (China); Fa, Huanbao [College of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044 (China)

    2016-02-28

    Graphical abstract: A novel and sensitive electrochemical biosensor based on hybrid nanocomposite consisting of copper oxide nanowires (CuO NWs) and carboxyl-functionalized single-walled carbon nanotubes (SWCNTs-COOH) was first developed for the detection of the specific-sequence target DNA. This schematic represents the fabrication procedure of our DNA biosensor. - Highlights: • An ultrasensitive DNA electrochemical biosensor was developed. • CuO NWs entangled with the SWCNTs formed a mesh structure with good conductivity. • It is the first time use of CuONWs-SWCNTs hybrid nanocomposite for DNA detection. • The biosensor is simple, selective, stable, and sensitive. • The biosensor has great potential for use in analysis of real samples. - Abstract: Here, we developed a novel and sensitive electrochemical biosensor to detect specific-sequence target DNA. The biosensor was based on a hybrid nanocomposite consisting of copper oxide nanowires (CuO NWs) and carboxyl-functionalized single-walled carbon nanotubes (SWCNTs-COOH). The resulting CuO NWs/SWCNTs layers exhibited a good differential pulse voltammetry (DPV) current response for the target DNA sequences, which we attributed to the properties of CuO NWs and SWCNTs. CuO NWs and SWCNTs hybrid composites with highly conductive and biocompatible nanostructure were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), and cyclic voltammetry (CV). Immobilization of the probe DNA on the electrode surface was largely improved due to the unique synergetic effect of CuO NWs and SWCNTs. DPV was applied to monitor the DNA hybridization event, using adriamycin as an electrochemical indicator. Under optimal conditions, the peak currents of adriamycin were linear with the logarithm of target DNA concentrations (ranging from 1.0 × 10{sup −14} to 1.0 × 10{sup −8} M), with a detection limit of 3.5 × 10{sup −15} M (signal/noise ratio of 3). The biosensor also showed high

  2. Identification of multivariate models for noise analysis of nuclear plant

    International Nuclear Information System (INIS)

    Zwingelstein, G.C.; Upadhyaya, B.R.

    1979-01-01

    During the normal operation of a pressurized water reactor, neutron noise analysis with multivariate autoregressive procedures in a valuable diagnostic tool to extract dynamic characteristics for incipient failure detection. The first part of the paper will describe in details the equations for estimating the multivariate autoregressive model matrices and the structure of various matrices. The matrices are estimated by solving a set of matrix operations, called Yule-Walker equations. The selection of optimal model order will also be discussed. Once the optimal parameter set is obtained, simple and fast calculations are used to determine the auto power spectral density, cross spectra, coherence function, phase. In addition the spectra may be decomposed into components being contributed from different noise sources. An application using neutron flux data collected on a nuclear plant will illustrate the efficiency of the method

  3. Monitoring the mechanical vibration of in-core detector tubes and fuel channels via ICFD noise analysis

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Czuppon, G.J.; Kapoor, K.K.

    2000-01-01

    Vibrations of core internals are regularly monitored in the CANDU nuclear generating stations of Ontario Power Generation (OPG) via the noise analysis of in-core flux detectors (ICFDs). Voltage signals of standard station instrumentation are recorded by portable multi-channel high-speed high-resolution data acquisition systems, then statistical parameters are derived from the multi-channel time series measurements. Reactor noise analysis is a non-intrusive statistical technique regularly used in system surveillance, diagnostics and in actual operational I and C problems. It utilizes the dynamic information carried by the small fluctuations (noise) of station signals measured around their mean values during steady-state operation. The present paper discusses specific results related to the flow-induced mechanical vibrations of detector tubes and fuel channels. (author)

  4. Simulation of reactor noise analysis measurement for light-water critical assembly TCA using MCNP-DSP

    International Nuclear Information System (INIS)

    Yamamoto, Toshihiro; Sakurai, Kiyoshi; Tonoike, Kotaro; Miyoshi, Yoshinori

    2001-01-01

    Reactor noise analysis methods using Monte Carlo technique have been proposed and developed in the field of nuclear criticality safety. The Monte Carlo simulation for noise analysis can be made by simulating physical phenomena in the course of neutron transport in a nuclear fuel as practically as possible. MCNP-DSP was developed by T. Valentine of ORNL for this purpose and it is a modified version of MCNP-4A. The authors applied this code to frequency analysis measurements performed in light-water critical assembly TCA. Prompt neutron generation times for critical and subcritical cores were measured by doing the frequency analysis of detector signals. The Monte Carlo simulations for these experiments were carried out using MCNP-DSP, and prompt neutron generation times were calculated. (author)

  5. Analysis of the Noise Characteristics of CMOS Current Conveyors

    DEFF Research Database (Denmark)

    Bruun, Erik

    1997-01-01

    The definition of the current conveyor is reviewed and a multiple-output second generation current conveyor (CCII) is shown to combine the different generations of current conveyors presently existing. Next, noise sources are introduced, and a general noise model for the current conveyor is descr......The definition of the current conveyor is reviewed and a multiple-output second generation current conveyor (CCII) is shown to combine the different generations of current conveyors presently existing. Next, noise sources are introduced, and a general noise model for the current conveyor...

  6. A Review of Surface Analysis Techniques for the Investigation of the Phenomenon of Electrochemical Promotion of Catalysis with Alkaline Ionic Conductors

    Directory of Open Access Journals (Sweden)

    Jesús González-Cobos

    2016-01-01

    Full Text Available Electrochemical Promotion of Catalysis (EPOC with alkali ionic conductors has been widely studied in literature due to its operational advantages vs. alkali classical promotion. This phenomenon allows to electrochemically control the alkali promoter coverage on a catalyst surface in the course of the catalytic reaction. Along the study of this phenomenon, a large variety of in situ and ex situ surface analysis techniques have been used to investigate the origin and mechanism of this kind of promotion. In this review, we analyze the most important contributions made on this field which have clearly evidenced the presence of adsorbed alkali surface species on the catalyst films deposited on alkaline solid electrolyte materials during EPOC experiments. Hence, the use of different surface analysis techniques such as scanning electron microscopy (SEM, energy-dispersive X-ray spectroscopy (EDX, X-ray diffraction (XRD, X-ray photoelectron spectroscopy (XPS, scanning photoelectron microscopy (SPEM, or scanning tunneling microscopy (STM, led to a better understanding of the alkali promoting effect, and served to confirm the theory of electrochemical promotion on this kind of catalytic systems. Given the functional similarities between alkali electrochemical and chemical promotion, this review aims to bring closer this phenomenon to the catalysis scientific community.

  7. Electrochemically Pretreated Carbon Microfiber Electrodes as Sensitive HPLC-EC Detectors

    Directory of Open Access Journals (Sweden)

    Zdenka Bartosova

    2012-01-01

    Full Text Available The paper focuses on the analysis and detection of electroactive compounds using high-performance liquid chromatography (HPLC combined with electrochemical detection (EC. The fabrication and utilization of electrochemically treated carbon fiber microelectrodes (CFMs as highly sensitive amperometric detectors in HPLC are described. The applied pretreatment procedure is beneficial for analytical characteristics of the sensor as demonstrated by analysis of the model set of phenolic acids. The combination of CFM with separation power of HPLC technique allows for improved detection limits due to unique electrochemical properties of carbon fibers. The CFM proved to be a promising tool for amperometric detection in liquid chromatography.

  8. Platinum nanoparticles functionalized nitrogen doped graphene platform for sensitive electrochemical glucose biosensing

    International Nuclear Information System (INIS)

    Yang, Zhanjun; Cao, Yue; Li, Juan; Jian, Zhiqin; Zhang, Yongcai; Hu, Xiaoya

    2015-01-01

    Highlights: • An efficient PtNPs@NG nanocomposite was prepared for the immobilization of enzyme. • A novel electrochemical glucose biosensor was constructed based on this PtNPs@NG. • The proposed glucose biosensor showed high sensitivity and low detection limit. • The PtNPs@NG composite provided a promising platform for biosensing applications. - Abstract: In this work, we reported an efficient platinum nanoparticles functionalized nitrogen doped graphene (PtNPs@NG) nanocomposite for devising novel electrochemical glucose biosensor for the first time. The fabricated PtNPs@NG and biosensor were characterized using transmission electron microscopy, high-resolution transmission electron microscopy, X-ray photoelectron spectroscopy, static water contact angle, UV–vis spectroscopy, electrochemical impedance spectra and cyclic voltammetry, respectively. PtNPs@NG showed large surface area and excellent biocompatibility, and enhanced the direct electron transfer between enzyme molecules and electrode surface. The glucose oxidase (GOx) immobilized on PtNPs@NG nanocomposite retained its bioactivity, and exhibited a surface controlled, quasi-reversible and fast electron transfer process. The constructed glucose biosensor showed wide linear range from 0.005 to 1.1 mM with high sensitivity of 20.31 mA M −1 cm −2 . The detection limit was calculated to be 0.002 mM at signal-to-noise of 3, which showed 20-fold decrease in comparison with single NG-based electrochemical biosensor for glucose. The proposed glucose biosensor also demonstrated excellent selectivity, good reproducibility, acceptable stability, and could be successfully applied in the detection of glucose in serum samples at the applied potential of −0.33 V. This research provided a promising biosensing platform for the development of excellent electrochemical biosensors

  9. Platinum nanoparticles functionalized nitrogen doped graphene platform for sensitive electrochemical glucose biosensing

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhanjun, E-mail: zjyang@yzu.edu.cn; Cao, Yue; Li, Juan; Jian, Zhiqin; Zhang, Yongcai; Hu, Xiaoya

    2015-04-29

    Highlights: • An efficient PtNPs@NG nanocomposite was prepared for the immobilization of enzyme. • A novel electrochemical glucose biosensor was constructed based on this PtNPs@NG. • The proposed glucose biosensor showed high sensitivity and low detection limit. • The PtNPs@NG composite provided a promising platform for biosensing applications. - Abstract: In this work, we reported an efficient platinum nanoparticles functionalized nitrogen doped graphene (PtNPs@NG) nanocomposite for devising novel electrochemical glucose biosensor for the first time. The fabricated PtNPs@NG and biosensor were characterized using transmission electron microscopy, high-resolution transmission electron microscopy, X-ray photoelectron spectroscopy, static water contact angle, UV–vis spectroscopy, electrochemical impedance spectra and cyclic voltammetry, respectively. PtNPs@NG showed large surface area and excellent biocompatibility, and enhanced the direct electron transfer between enzyme molecules and electrode surface. The glucose oxidase (GOx) immobilized on PtNPs@NG nanocomposite retained its bioactivity, and exhibited a surface controlled, quasi-reversible and fast electron transfer process. The constructed glucose biosensor showed wide linear range from 0.005 to 1.1 mM with high sensitivity of 20.31 mA M{sup −1} cm{sup −2}. The detection limit was calculated to be 0.002 mM at signal-to-noise of 3, which showed 20-fold decrease in comparison with single NG-based electrochemical biosensor for glucose. The proposed glucose biosensor also demonstrated excellent selectivity, good reproducibility, acceptable stability, and could be successfully applied in the detection of glucose in serum samples at the applied potential of −0.33 V. This research provided a promising biosensing platform for the development of excellent electrochemical biosensors.

  10. Analysis and removing noise from speech using wavelet transform

    Science.gov (United States)

    Tomala, Karel; Voznak, Miroslav; Partila, Pavol; Rezac, Filip; Safarik, Jakub

    2013-05-01

    The paper discusses the use of Discrete Wavelet Transform (DWT) and Stationary Wavelet Transform (SWT) wavelet in removing noise from voice samples and evaluation of its impact on speech quality. One significant part of Quality of Service (QoS) in communication technology is the speech quality assessment. However, this part is seriously overlooked as telecommunication providers often focus on increasing network capacity, expansion of services offered and their enforcement in the market. Among the fundamental factors affecting the transmission properties of the communication chain is noise, either at the transmitter or the receiver side. A wavelet transform (WT) is a modern tool for signal processing. One of the most significant areas in which wavelet transforms are used is applications designed to suppress noise in signals. To remove noise from the voice sample in our experiment, we used the reference segment of the voice which was distorted by Gaussian white noise. An evaluation of the impact on speech quality was carried out by an intrusive objective algorithm Perceptual Evaluation of Speech Quality (PESQ). DWT and SWT transformation was applied to voice samples that were devalued by Gaussian white noise. Afterwards, we determined the effectiveness of DWT and SWT by means of objective algorithm PESQ. The decisive criterion for determining the quality of a voice sample once the noise had been removed was Mean Opinion Score (MOS) which we obtained in PESQ. The contribution of this work lies in the evaluation of efficiency of wavelet transformation to suppress noise in voice samples.

  11. Electrochemical energy generation

    International Nuclear Information System (INIS)

    Kreysa, G.; Juettner, K.

    1993-01-01

    The proceedings encompass 40 conference papers belonging to the following subject areas: Baseline and review papers; electrochemical fuel cells; batteries: Primary and secondary cells; electrochemical, regenerative systems for energy conversion; electrochemical hydrogen generation; electrochemistry for nuclear power plant; electrochemistry for spent nuclear fuel reprocessing; energy efficiency in electrochemical processes. There is an annex listing the authors and titles of the poster session, and compacts of the posters can be obtained from the office of the Gesellschaft Deutscher Chemiker, Abteilung Tagungen. (MM) [de

  12. A temporal and spatial analysis of anthropogenic noise sources affecting SNMR

    Science.gov (United States)

    Dalgaard, E.; Christiansen, P.; Larsen, J. J.; Auken, E.

    2014-11-01

    One of the biggest challenges when using the surface nuclear magnetic resonance (SNMR) method in urban areas is a relatively low signal level compared to a high level of background noise. To understand the temporal and spatial behavior of anthropogenic noise sources like powerlines and electric fences, we have developed a multichannel instrument, noiseCollector (nC), which measures the full noise spectrum up to 10 kHz. Combined with advanced signal processing we can interpret the noise as seen by a SNMR instrument and also obtain insight into the more fundamental behavior of the noise. To obtain a specified acceptable noise level for a SNMR sounding the stack size can be determined by quantifying the different noise sources. Two common noise sources, electromagnetic fields stemming from powerlines and fences are analyzed and show a 1/r2 dependency in agreement with theoretical relations. A typical noise map, obtained with the nC instrument prior to a SNMR field campaign, clearly shows the location of noise sources, and thus we can efficiently determine the optimal location for the SNMR sounding from a noise perspective.

  13. Analysis of modeling aircraft noise with the Nord2000 noise model

    Science.gov (United States)

    2012-10-31

    This report provides comparisons between AEDT/INM and the Nord 2000 Noise Models for the following parameters: ground type, simple terrain (downward slope, upward slope, hill), temperature and humidity, temperature gradients (positive and negative), ...

  14. Deconvolution under Poisson noise using exact data fidelity and synthesis or analysis sparsity priors

    OpenAIRE

    Dupé , François-Xavier; Fadili , Jalal M.; Starck , Jean-Luc

    2012-01-01

    International audience; In this paper, we propose a Bayesian MAP estimator for solving the deconvolution problems when the observations are corrupted by Poisson noise. Towards this goal, a proper data fidelity term (log-likelihood) is introduced to reflect the Poisson statistics of the noise. On the other hand, as a prior, the images to restore are assumed to be positive and sparsely represented in a dictionary of waveforms such as wavelets or curvelets. Both analysis and synthesis-type spars...

  15. The CEA program on boiling noise detection

    International Nuclear Information System (INIS)

    Le Guillou, G.; Brunet, M.; Girard, J.P.; Flory, D.

    1982-01-01

    The research program on the application of noise analysis on boiling detection in a fast subassembly began 10 years ago at the CEA, mainly in the Nuclear Center of Cadarache. Referring exclusively to the aspects of premature detection of the boiling phenomenon it can be said that this program is organized around the following three detection techniques: acoustic noise analysis; neutron noise analysis; temperature noise analysis. Its development is in conjunction with in-pile experiments in Phenix or Rapsodie as well as 'ex-pile' (boiling experiments through electric heating). Three detection techniques were developed independent of each other, but that they were regrouped during the execution of the most important experiments and with the 'Super Phenix' project. The noise analysis system ANABEL with which Superphenix will be equipped with shows the industrial interest in detection methods based on noises. One of the results of the CEA program today is the possibility to evaluate the potential capacity for boiling detection in the subassembly. But in order to obtain the necessary funds from the commercial nuclear plant operators it is mandatory to have successful demonstrations which will be the objective of the future program

  16. Noise upon the Sinusoids

    DEFF Research Database (Denmark)

    Jensen, Karl Kristoffer

    2005-01-01

    Sinusoids are used for making harmonic and other sounds. In order to having life in the sounds and adding a wide variety of noises, irregularities are inserted in the frequency and amplitudes. A simple and intuitive noise model is presented, consisting of a low-pass filtered noise, and having...... control for strength and bandwidth. The noise is added on the frequency and amplitudes of the sinusoids, and the resulting irregularity’s (jitter and shimmer) bandwidth is derived. This, together with an overview of investigation methods of the jitter and shimmer results in an analysis of the necessary...

  17. Reliable clinical serum analysis with reusable electrochemical sensor: Toward point-of-care measurement of the antipsychotic medication clozapine.

    Science.gov (United States)

    Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F

    2017-09-15

    Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development of an electrometer/amplifier and filter set for analysis of reactor noise

    International Nuclear Information System (INIS)

    Strohl, Claude Emile

    1996-01-01

    In nuclear power reactors, the neutron detector signal is dependent on the number of fissions and the reactor power level. The detector signal can be divided into two components: a D C component, proportional to the average value and an A C component, which is the fluctuating part superimposed to the D C component. The analysis of the fluctuating part of the signal is called noise analysis and allow us to investigate phenomena occurring within the reactor vessel, such as vibrational of fuel elements and coolant density, temperature, pressure and flow changes. On the other hand, the measure of the static D C part allows us to measure the local power density. This work describes the development of a personal computer based signal conditioning card that, together with a personal computer commercial data acquisition card, can be used for noise analysis and reactivity measurements of signals coming from ionization chambers or SPD's. (author)

  19. Using white noise to gate organic transistors for dynamic monitoring of cultured cell layers.

    Science.gov (United States)

    Rivnay, Jonathan; Leleux, Pierre; Hama, Adel; Ramuz, Marc; Huerta, Miriam; Malliaras, George G; Owens, Roisin M

    2015-06-26

    Impedance sensing of biological systems allows for monitoring of cell and tissue properties, including cell-substrate attachment, layer confluence, and the "tightness" of an epithelial tissue. These properties are critical for electrical detection of tissue health and viability in applications such as toxicological screening. Organic transistors based on conducting polymers offer a promising route to efficiently transduce ionic currents to attain high quality impedance spectra, but collection of complete impedance spectra can be time consuming (minutes). By applying uniform white noise at the gate of an organic electrochemical transistor (OECT), and measuring the resulting current noise, we are able to dynamically monitor the impedance and thus integrity of cultured epithelial monolayers. We show that noise sourcing can be used to track rapid monolayer disruption due to compounds which interfere with dynamic polymerization events crucial for maintaining cytoskeletal integrity, and to resolve sub-second alterations to the monolayer integrity.

  20. Aspect-dependent radiated noise analysis of an underway autonomous underwater vehicle.

    Science.gov (United States)

    Gebbie, John; Siderius, Martin; Allen, John S

    2012-11-01

    This paper presents an analysis of the acoustic emissions emitted by an underway REMUS-100 autonomous underwater vehicle (AUV) that were obtained near Honolulu Harbor, HI using a fixed, bottom-mounted horizontal line array (HLA). Spectral analysis, beamforming, and cross-correlation facilitate identification of independent sources of noise originating from the AUV. Fusion of navigational records from the AUV with acoustic data from the HLA allows for an aspect-dependent presentation of calculated source levels of the strongest propulsion tone.

  1. Nanomaterials application in electrochemical detection of heavy metals

    International Nuclear Information System (INIS)

    Aragay, Gemma; Merkoçi, Arben

    2012-01-01

    Highlights: ► We review the recent trends in the application of nanomaterials for electrochemical detection of heavy metals. ► Different types of nanomaterials including metal nanoparticles, different carbon nanomaterials or nanochannels have been applied on the electrochemical analysis of heavy metals in various sensing formats/configurations. ► The great properties of nanomaterials allow the new devices to show advantages in terms of sensing performance (i.e. increase the sensitivity, decrease the detection limits and improve the stability). ► Between the various electrochemical techniques, voltammetric and potentiometric based ones are particularly taking interesting advantages by the incorporation of new nanomaterials due to the improved electrocatalytic properties beside the increase of the sensor's transducing area. - Abstract: Recent trends in the application of nanomaterials for electrochemical detection of heavy metals are shown. Various nanomaterials such as nanoparticles, nanowires, nanotubes, nanochannels, graphene, etc. have been explored either as modifiers of electrodes or as new electrode materials with interest to be applied in electrochemical stripping analysis, ion-selective detection, field-effect transistors or other indirect heavy metals (bio)detection alternatives. The developed devices have shown increased sensitivity and decreased detection limits between other improvements of analytical performance data. The phenomena behind nanomaterials responses are also discussed and some typical responses data of the developed systems either in standard solutions or in real samples are given. The developed nanomaterials based electrochemical systems are giving new inputs to the existing devices or leading to the development of novel heavy metal detection tools with interest for applications in field such as diagnostics, environmental and safety and security controls or other industries.

  2. Osmium tetroxide complexes as versatile tools for structure probing and electrochemical analysis of biopolymers

    Czech Academy of Sciences Publication Activity Database

    Fojta, Miroslav; Kostečka, Pavel; Pivoňková, Hana; Horáková Brázdilová, Petra; Havran, Luděk

    2011-01-01

    Roč. 7, č. 1 (2011), s. 35-50 ISSN 1573-4110 R&D Projects: GA AV ČR(CZ) IAA400040901; GA AV ČR(CZ) IAA400040903; GA ČR(CZ) GP203/08/P598; GA MŠk(CZ) LC06035 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : osmium complexes * DNA labelling * electrochemical analysis Subject RIV: BO - Biophysics Impact factor: 1.000, year: 2011

  3. Design of a high-speed electrochemical scanning tunneling microscope.

    Science.gov (United States)

    Yanson, Y I; Schenkel, F; Rost, M J

    2013-02-01

    In this paper, we present a bottom-up approach to designing and constructing a high-speed electrochemical scanning tunneling microscope (EC-STM). Using finite element analysis (FEA) calculations of the frequency response of the whole mechanical loop of the STM, we analyzed several geometries to find the most stable one that could facilitate fast scanning. To test the FEA results, we conducted measurements of the vibration amplitudes using a prototype STM setup. Based on the FEA analysis and the measurement results, we identified the potentially most disturbing vibration modes that could impair fast scanning. By modifying the design of some parts of the EC-STM, we reduced the amplitudes as well as increased the resonance frequencies of these modes. Additionally, we designed and constructed an electrochemical flow-cell that allows STM imaging in a flowing electrolyte, and built a bi-potentiostat to achieve electrochemical potential control during the measurements. Finally, we present STM images acquired during high-speed imaging in air as well as in an electrochemical environment using our newly-developed EC-STM.

  4. The use of magnetic Barkhausen noise analysis for nondestructive determination of stresses in structural elements

    International Nuclear Information System (INIS)

    Silva Junior, Silverio Ferreira da; Mansur, Tanius Rodrigues; Cruz, Julio Ricardo Barreto

    2007-01-01

    The knowledge about the stress state acting in structural elements has significant importance in the structural integrity evaluation of a specific component. The magnetic Barkhausen noise analysis can be used for this purpose. As a nondestructive testing method, it presents the advantage of not promote any changes in the tested component. In this paper, a study about the use of this new nondestructive test method for stress measurements is presented. The test system configuration and the reference standards used for this purpose, as well as the optimum test parameters determination are discussed. The experiments were carried out in ASTM A-36 steel, used for structural components manufacturing. A structure of this material was loaded and the resulting stresses were determined from strain gage measurements and Barkhausen noise analysis. The results obtained have showed a good sensitivity of the magnetic Barkhausen noise to stress changes occurred in the material. The main advantages and limitations of this test method for stress measurements are presented. (author)

  5. Noise problems in coal mining complex- a case discussion

    International Nuclear Information System (INIS)

    Mishra, Y.; Mitra, H.; Ghosh, S.; Pal, A.K.

    1996-01-01

    Noise monitoring study was conducted at Moonidih mining complex of Jharia coal-field. The study included monitoring and analysis of ambient as well as workplace noise levels. An attempt has been made to critically analyse the noise situation through octave band analysis, thereby identifying alarming noise frequencies for each noise generating equipment having Leq level more than 90 dBA. A noise model has also been developed to draw noise contours of the entire mining complex. Based on these studies, suitable control measures have been suggested. (author). 6 refs., 3 figs

  6. Noise suppression by noise

    OpenAIRE

    Vilar, J. M. G. (José M. G.), 1972-; Rubí Capaceti, José Miguel

    2001-01-01

    We have analyzed the interplay between an externally added noise and the intrinsic noise of systems that relax fast towards a stationary state, and found that increasing the intensity of the external noise can reduce the total noise of the system. We have established a general criterion for the appearance of this phenomenon and discussed two examples in detail.

  7. Analysis and development of deterministic and stochastic neutron noise computing techniques with applications to thermal and fast reactors

    International Nuclear Information System (INIS)

    Rouchon, Amelie

    2016-01-01

    Neutron noise analysis addresses the description of small time-dependent flux fluctuations induced by small global or local perturbations of the macroscopic cross-sections. These fluctuations may occur in nuclear reactors due to density fluctuations of the coolant, to vibrations of fuel elements, control rods, or any other structures in the core. In power reactors, ex-core and in-core detectors can be used to monitor neutron noise with the aim of detecting possible anomalies and taking the necessary measures for continuous safe power production. The objective of this thesis is to develop techniques for neutron noise analysis and especially to implement a neutron noise solver in the deterministic transport code APOLLO3 developed at CEA. A new Monte Carlo algorithm that solves the transport equations for the neutron noise has been also developed. In addition, a new vibration model has been developed. Moreover, a method based on the determination of a new steady state has been proposed for the linear and the nonlinear full theory so as to improve the traditional neutron noise theory. In order to test these new developments we have performed neutron noise simulations in one-dimensional systems and in a large pressurized water reactor with heavy baffle in two and three dimensions with APOLLO3 in diffusion and transport theories. (author) [fr

  8. Noise analysis of genome-scale protein synthesis using a discrete computational model of translation

    Energy Technology Data Exchange (ETDEWEB)

    Racle, Julien; Hatzimanikatis, Vassily, E-mail: vassily.hatzimanikatis@epfl.ch [Laboratory of Computational Systems Biotechnology, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Swiss Institute of Bioinformatics (SIB), CH-1015 Lausanne (Switzerland); Stefaniuk, Adam Jan [Laboratory of Computational Systems Biotechnology, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2015-07-28

    Noise in genetic networks has been the subject of extensive experimental and computational studies. However, very few of these studies have considered noise properties using mechanistic models that account for the discrete movement of ribosomes and RNA polymerases along their corresponding templates (messenger RNA (mRNA) and DNA). The large size of these systems, which scales with the number of genes, mRNA copies, codons per mRNA, and ribosomes, is responsible for some of the challenges. Additionally, one should be able to describe the dynamics of ribosome exchange between the free ribosome pool and those bound to mRNAs, as well as how mRNA species compete for ribosomes. We developed an efficient algorithm for stochastic simulations that addresses these issues and used it to study the contribution and trade-offs of noise to translation properties (rates, time delays, and rate-limiting steps). The algorithm scales linearly with the number of mRNA copies, which allowed us to study the importance of genome-scale competition between mRNAs for the same ribosomes. We determined that noise is minimized under conditions maximizing the specific synthesis rate. Moreover, sensitivity analysis of the stochastic system revealed the importance of the elongation rate in the resultant noise, whereas the translation initiation rate constant was more closely related to the average protein synthesis rate. We observed significant differences between our results and the noise properties of the most commonly used translation models. Overall, our studies demonstrate that the use of full mechanistic models is essential for the study of noise in translation and transcription.

  9. Rotary Compressor Noise Analysis Using Mechanisms and Electromagnetics Coupled Approach

    OpenAIRE

    Chung, Jinah; Lee, Uiyoon; Lee, Jeongbae; Lee, Unseop; Han, Eunsil; Yoon, Jinhwan

    2016-01-01

    This research is conducted to investigate noise source and design low noise compressors. For improving energy efficiency, the rotary compressor with variable speed brushless DC motor is increasingly adopted for appliances. However brushless DC motor makes more compressor vibration than constant speed motor compressor at high speed operating condition. Therefore it is necessary to reduce noise and vibration for improving air conditioner quality. In this study, compressor’s noise and vibrat...

  10. Analysis of plasma microRNA expression profiles in male textile workers with noise-induced hearing loss.

    Science.gov (United States)

    Ding, Lu; Liu, Jing; Shen, Huan-Xi; Pan, Li-Ping; Liu, Qing-Dong; Zhang, Heng-Dong; Han, Lei; Shuai, Li-Guo; Ding, En-Min; Zhao, Qiu-Ni; Wang, Bo-Shen; Zhu, Bao-Li

    2016-03-01

    Circulating microRNAs (miRNAs) have attracted interests as non-invasive biomarkers of physiological and pathological conditions, which may be applied in noise-induced hearing loss (NIHL). However, no epidemiology studies have yet examined the potential effects of NIHL or noise exposure on miRNA expression profiles. We sought to identify permanent NIHL-related miRNAs and to predict the biological functions of the putative genes encoding the indicated miRNAs. In the discovery stage, we used a microarray assay to detect the miRNA expression profiles between pooled plasma samples from 10 noise-exposed individuals with normal hearing and 10 NIHL patients. In addition, we conducted a preliminary validation of six candidate miRNAs in the same 20 workers. Subsequently, three miRNAs were selected for expanded validation in 23 non-exposed individuals with normal hearing and 46 noise-exposed textile workers which including 23 noise-exposed workers with normal hearing and 23 NIHL patients. Moreover, we predicted the biological functions of the putative target genes using a Gene Ontology (GO) function enrichment analysis. In the discovery stage, compared with the noise exposures with normal hearing, 73 miRNAs demonstrated at least a 1.5-fold differential expression in the NIHL patients. In the preliminary validation, compared with the noise exposures, the plasma levels of miR-16-5p, miR-24-3p, miR-185-5p and miR-451a were all upregulated (P < 0.001) in the NIHL patients. In the expanded validation stage, compared with the non-exposures, the plasma levels of miR-24, miR-185-5p and miR-451a were all significantly downregulated (P < 0.001) in the exposures. And compared with the noise exposures, the plasma levels of miR-185-5p and miR-451a were slightly elevated (P < 0.001) in the NIHL patients, which were consistent with the results of preliminary validation and microarray analysis. The two indicated plasma miRNAs may be biomarkers of indicating responses to noise exposure

  11. Noise analysis based validation of the dynamics of in-core flux detectors and ion chambers used in SDS and RRS systems

    International Nuclear Information System (INIS)

    Gloeckler, O.; Cooke, D.; Tulett, M.V.

    1996-01-01

    The paper concentrates on some of the recent applications of reactor noise analysis in Ontario Hydro's CANDU stations, related to the dynamics of in-core flux detectors (ICFDs) and ion chambers. These applications include (1) detecting anomalies in the dynamics of ICFDs and ion chambers, (2) estimating the effective prompt fractions of ICFDs in power rundown tests and in noise measurement, (3) detecting the mechanical vibration of ICFD instrument tubes induced by moderator flow, (4) detecting the mechanical vibration of fuel channels induced by coolant flow, (5) identifying the cause of excessive signal fluctuations in certain flux detectors, (6) validating the dynamic coupling between liquid zone control signals. Some of these applications are performed on a regular basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the AECB with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology (author)

  12. Noise in restaurants: levels and mathematical model.

    Science.gov (United States)

    To, Wai Ming; Chung, Andy

    2014-01-01

    Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (L(eq,1-h)) was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  13. Noise in restaurants: Levels and mathematical model

    Directory of Open Access Journals (Sweden)

    Wai Ming To

    2014-01-01

    Full Text Available Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (Leq,1-h was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  14. The noise analysis and the BWR operation map

    International Nuclear Information System (INIS)

    Blazquez, J.; Ballestrin, J.

    1996-01-01

    An analytical expression for the Decay Ratio is obtained: DR = exp(-bW / P 1/2 ). The physics behind is also explained. It applies to a commercial BWR Operation Map, on the vicinity of the power instability. This functional form seems fitting to the structure of the Operation map. The power P and the coolant flow are measured straightforward; the Decay Ratio is obtained by neutron noise analysis techniques. The parameter b, depending on the void reactivity coefficient, is then calculated on line during the Reactor Operation. New DR value is now predicted for each new displacement on the Map, so unexpected instability events are more likely avoided. (authors)

  15. Noise properties of Hilbert transform evaluation

    International Nuclear Information System (INIS)

    Pavliček, Pavel; Svak, Vojtěch

    2015-01-01

    The Hilbert transform is a standard method for the calculation of the envelope and phase of a modulated signal in optical measurement methods. Usually, the intensity of light is converted into an electric signal at a detector. Therefore the actual spatially or temporally sampled signal is always affected by noise. Because the noise values of individual samples are independent, the noise can be considered as white. If the envelope and phase are calculated from the noised signal, they will also be affected by the noise. We calculate the variance and spectral density of both the envelope noise and the phase noise. We determine which parameters influence the variance and spectral density of both the envelope noise and the phase noise. Finally, we determine the influence of the noise on the measurement uncertainty in white-light interferometry and fringe-pattern analysis. (paper)

  16. Measures of the zero power nuclear reactor's kinetic parameters with application of noise analysis

    International Nuclear Information System (INIS)

    Martins, F.R.

    1992-01-01

    The purpose of this work was to establish an experimental technique based on noise analysis for measuring the ratio of kinetic parameters β/ Λ and the power of the Zero Power Nuclear Reactor IPEN-MB 01. A through study of the microscopic and macroscopic noise analysis techniques has been carried out. The Langevin technique and the point kinetic model were chosen to describe the stochastic phenomena that occur in the zero power reactor. Measurements have been made using two compensated ionization chambers localized in the water reflector at symmetric positions in order to minimize spatial effects on the neutron flux fluctuation. Power calibrations based on the low frequency plateau of the cross-power spectral density has also been carried out. (author)

  17. Electrochemical performance studies of MnO2 nanoflowers recovered from spent battery

    International Nuclear Information System (INIS)

    Ali, Gomaa A.M.; Tan, Ling Ling; Jose, Rajan; Yusoff, Mashitah M.; Chong, Kwok Feng

    2014-01-01

    Highlights: • MnO 2 is recovered from spent zinc–carbon batteries as nanoflowers structure. • Recovered MnO 2 nanoflowers show high specific capacitance. • Recovered MnO 2 nanoflowers show stable electrochemical cycling up to 900 cycles. • Recovered MnO 2 nanoflowers show low resistance in EIS data. - Abstract: The electrochemical performance of MnO 2 nanoflowers recovered from spent household zinc–carbon battery is studied by cyclic voltammetry, galvanostatic charge/discharge cycling and electrochemical impedance spectroscopy. MnO 2 nanoflowers are recovered from spent zinc–carbon battery by combination of solution leaching and electrowinning techniques. In an effort to utilize recovered MnO 2 nanoflowers as energy storage supercapacitor, it is crucial to understand their structure and electrochemical performance. X-ray diffraction analysis confirms the recovery of MnO 2 in birnessite phase, while electron microscopy analysis shows the MnO 2 is recovered as 3D nanostructure with nanoflower morphology. The recovered MnO 2 nanoflowers exhibit high specific capacitance (294 F g −1 at 10 mV s −1 ; 208.5 F g −1 at 0.1 A g −1 ) in 1 M Na 2 SO 4 electrolyte, with stable electrochemical cycling. Electrochemical data analysis reveal the great potential of MnO 2 nanoflowers recovered from spent zinc–carbon battery in the development of high performance energy storage supercapacitor system

  18. Quantifying Chemical and Electrochemical Reactions in Liquids by in situ Electron Microscopy

    DEFF Research Database (Denmark)

    Canepa, Silvia

    and developing a robust imaging analysis method for quantitatively understand chemical and electrochemical process during in situ liquid electron microscopy. By using two custom-made liquid cells (an electrochemical scanning electron microscopy (EC-SEM) platform and Liquid Flow S/TEM holder) beam...... of electrochemical deposition of copper (Cu) by electrochemical liquid scanning electron microscopy (EC-SEM) was done in order to direct observe the formation of dendritic structures. Finally the shape evolution from solid to hollow structures through galvanic replacement reactions were observed for different silver...

  19. Improved CEEMDAN-wavelet transform de-noising method and its application in well logging noise reduction

    Science.gov (United States)

    Zhang, Jingxia; Guo, Yinghai; Shen, Yulin; Zhao, Difei; Li, Mi

    2018-06-01

    The use of geophysical logging data to identify lithology is an important groundwork in logging interpretation. Inevitably, noise is mixed in during data collection due to the equipment and other external factors and this will affect the further lithological identification and other logging interpretation. Therefore, to get a more accurate lithological identification it is necessary to adopt de-noising methods. In this study, a new de-noising method, namely improved complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN)-wavelet transform, is proposed, which integrates the superiorities of improved CEEMDAN and wavelet transform. Improved CEEMDAN, an effective self-adaptive multi-scale analysis method, is used to decompose non-stationary signals as the logging data to obtain the intrinsic mode function (IMF) of N different scales and one residual. Moreover, one self-adaptive scale selection method is used to determine the reconstruction scale k. Simultaneously, given the possible frequency aliasing problem between adjacent IMFs, a wavelet transform threshold de-noising method is used to reduce the noise of the (k-1)th IMF. Subsequently, the de-noised logging data are reconstructed by the de-noised (k-1)th IMF and the remaining low-frequency IMFs and the residual. Finally, empirical mode decomposition, improved CEEMDAN, wavelet transform and the proposed method are applied for analysis of the simulation and the actual data. Results show diverse performance of these de-noising methods with regard to accuracy for lithological identification. Compared with the other methods, the proposed method has the best self-adaptability and accuracy in lithological identification.

  20. Ultrasensitive molecularly imprinted electrochemical sensor based on magnetism graphene oxide/β-cyclodextrin/Au nanoparticles composites for chrysoidine analysis

    International Nuclear Information System (INIS)

    Wang, Xiaojiao; Li, Xiangjun; Luo, Chuannan; Sun, Min; Li, Leilei; Duan, Huimin

    2014-01-01

    Highlights: • Synthesis and application of MGO/β-CD@AuNPs as a sensor for chrysoidine analysis. • The synthesized polymer had a laminar structure with high surface. • The propose sensor showed high selectivity and good sensitivity. - Abstract: A imprinted electrochemical sensor based on glassy carbon electrode (GCE) for ultrasensitive detection of chrysoidine was fabricated. A GCE was modified by magnetic graphene oxide/β-cyclodextrin/gold nanoparticles composites (MGO/β-CD@AuNPs). The sensing surface area and electronic transmission rate were increased, which was benefited from the distribution property of MGO/β-CD@AuNPs. The MGO/β-CD@AuNPs composite improved electrochemical response and sensitivity of the sensor. The molecularly imprinted electrochemical sensor was prepared by electropolymerization on modified electrode. Chrysoidine and pyrrole were used as template molecule and functional monomer, respectively. Under the optimization experimental conditions, the electrochemical sensor exhibited excellent analytical performance: the detection of chrysoidine ranged from 5.0 × 10 −8 mol/L to 5.0 × 10 −6 mol/L with the detection limit of 1.7 × 10 −8 mol/L. The sensor was applied to determine chrysoidine in spiked water samples and showed high selectivity, good sensitivity and acceptable reproducibility. The proposed method provides a promising platform for trace amount detection of other food additives

  1. Comparison of JADE and canonical correlation analysis for ECG de-noising.

    Science.gov (United States)

    Kuzilek, Jakub; Kremen, Vaclav; Lhotska, Lenka

    2014-01-01

    This paper explores differences between two methods for blind source separation within frame of ECG de-noising. First method is joint approximate diagonalization of eigenmatrices, which is based on estimation of fourth order cross-cummulant tensor and its diagonalization. Second one is the statistical method known as canonical correlation analysis, which is based on estimation of correlation matrices between two multidimensional variables. Both methods were used within method, which combines the blind source separation algorithm with decision tree. The evaluation was made on large database of 382 long-term ECG signals and the results were examined. Biggest difference was found in results of 50 Hz power line interference where the CCA algorithm completely failed. Thus main power of CCA lies in estimation of unstructured noise within ECG. JADE algorithm has larger computational complexity thus the CCA perfomed faster when estimating the components.

  2. Fractals in Power Reactor Noise

    International Nuclear Information System (INIS)

    Aguilar Martinez, O.

    1994-01-01

    In this work the non- lineal dynamic problem of power reactor is analyzed using classic concepts of fractal analysis as: attractors, Hausdorff-Besikovics dimension, phase space, etc. A new non-linear problem is also analyzed: the discrimination of chaotic signals from random neutron noise signals and processing for diagnosis purposes. The advantages of a fractal analysis approach in the power reactor noise are commented in details

  3. Evaluation of the susceptibility to pitting corrosion of steel api 5L x42 exposed to solutions containing chloride ions and CO{sub 2} by electrochemical noise measurements; Evaluacion de la susceptibilidad a la corrosion por picado del acero api 5l x42 expuesto a un ambiente con cloruros y CO{sub 2} mediante la tecnica de ruido electroquimico

    Energy Technology Data Exchange (ETDEWEB)

    Pena-Ballesteros, D.; Rodriguez-Vanegas, N.; Anteliz, C.; Sarmiento Klapper, H.

    2011-07-01

    The concentration of chloride ions and the partial pressure of CO{sub 2} play an important role in the degradation of low-carbon steels used for the construction of pipelines in oil and gas industry. In order to evaluate the susceptibility of carbon steel API 5L X42 to pitting corrosion electrochemical noise and linear polarization resistance measurements were carried out in aqueous solutions containing chloride ions and CO{sub 2}. The concentration of chloride ions was varied between, 10000 and 18000 ppm, and the CO{sub 2} partial pressure between 10 psi and 18 psi. Experimental results pointed out that the formation of protective layer, consisting mainly of FeCO{sub 3}, depends on the partial pressure of CO{sub 2} in the system. Nevertheless, the stability of this layer was considerably affected by increasing the concentration of chloride ions causing that localized corrosion has taken place in some areas of the surface of API 5L X42, which were detected by electrochemical noise technique. (Author) 10 refs.

  4. Electrochemical treatment of liquid wastes

    International Nuclear Information System (INIS)

    Hobbs, D.

    1996-01-01

    Electrochemical treatment processes are being evaluated and developed for the destruction of organic compounds and nitrates/nitrites and the removal of other hazardous species from liquid wastes stored throughout the DOE complex. This activity consists of five major tasks: (1) evaluation of different electrochemical reactors for the destruction and removal of hazardous waste components, (2) development and validation of engineering process models, (3) radioactive laboratory-scale tests, (4) demonstration of the technology in an engineering-scale size reactor, and (5) analysis and evaluation of testing data. The development program team is comprised of individuals from federal, academic, and private industry. Work is being carried out in DOE, academic, and private industrial laboratories

  5. Measurements and analysis of neutron and gamma noise in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van; Kleiss, E.B.J.

    1985-01-01

    Neutron and gamma sensitive collectrons (self-powered detectors) have been designed for incore noise measurements in BWRs. A so-called twin-type has been developed for measurements of two-phase flow characteristics and detailed axial velocity distributions. Construction aspects of the twin detectors are discussed. An analysis is presented of the response of both detector types to incore parametric fluctuations. This analysis is based on detector response functions which provide an insight into the 'field of view' of the two types. The results are supported by experimental verifications; it is shown that incore gamma detectors provide useful additional information about two-phase flow in a BWR. (author)

  6. The Combined Effects of Aircraft and Road Traffic Noise and Aircraft and Railway Noise on Noise Annoyance—An Analysis in the Context of the Joint Research Initiative NORAH

    Directory of Open Access Journals (Sweden)

    Jördis Wothge

    2017-08-01

    Full Text Available The Noise Related Annoyance Cognition and Health (NORAH research initiative is one of the most extensive studies on the physiological and psychological long-term effects of transportation noise in Europe. It includes research on the quality of life and annoyance as well as cardiovascular effects, sleep disturbance, breast cancer, blood pressure, depression and the cognitive development of children. Within the realm of the annoyance module of the study approximately 10,000 residents of the Rhine-Main district were surveyed on the combined effects of transportation noise. This included combined noise from aircraft and road traffic noise (N = 4905, or aircraft and railway noise (N = 4777. Results show that judgment of the total noise annoyance of participants was strongly determined by the sound source which was judged as more annoying (in this case aircraft noise. To a lesser extent, the average sound pressure level of the two present sources was also of relevance.

  7. Signal-to-noise ratio application to seismic marker analysis and fracture detection

    Science.gov (United States)

    Xu, Hui-Qun; Gui, Zhi-Xian

    2014-03-01

    Seismic data with high signal-to-noise ratios (SNRs) are useful in reservoir exploration. To obtain high SNR seismic data, significant effort is required to achieve noise attenuation in seismic data processing, which is costly in materials, and human and financial resources. We introduce a method for improving the SNR of seismic data. The SNR is calculated by using the frequency domain method. Furthermore, we optimize and discuss the critical parameters and calculation procedure. We applied the proposed method on real data and found that the SNR is high in the seismic marker and low in the fracture zone. Consequently, this can be used to extract detailed information about fracture zones that are inferred by structural analysis but not observed in conventional seismic data.

  8. A time-variant analysis of the 1/f^(2) phase noise in CMOS parallel LC-Tank quadrature oscillators

    DEFF Research Database (Denmark)

    Andreani, Pietro

    2006-01-01

    This paper presents a study of 1/f2 phase noise in quadrature oscillators built by connecting two differential LC-tank oscillators in a parallel fashion. The analysis clearly demonstrates the necessity of adopting a time-variant theory of phase noise, where a more simplistic, time...

  9. Investigation of power oscillation mechanisms based on noise analysis at Forsmark-1 BWR

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1996-01-01

    Noise analysis has been performed for stability test data collected during reactor start-up in January 1989 at the boiling water reactor (BWR) Forsmark unit 1. A unique instrumentation to measure local coolant flow in this reactor allowed investigation of dynamic interactions between neutron flux and coolant flow noise signals at different radial positions in the core. The causal relationship for these signals was evaluated based on a method called signal transmission path (STP) analysis with the aim of identifying the principal mechanism of power oscillations in this reactor. The results of the present study indicated that large amplitude power oscillations were induced by two instability mechanisms concurrent in the core. The first is the global void reactivity feedback effect which played the most significant role to power oscillations at a resonant frequency of about 0.53 Hz. The second is the thermal-hydraulics coupling with neutron kinetics, inducing resonant oscillations at about 0.45 Hz. The latter was found to be active only in a certain core region. A peculiar phenomenon of amplitude modulations observed in some local power range monitor (LPRM) signals was also examined. It was interpreted to occur as the consequence of these two resonant power oscillations, the frequencies of which lie close to each other. The noise analysis technique applied in the present study is expected to be useful to get a deeper understanding of the power oscillation mechanism which is active in the reactor under evaluation. The technique may be applicable to BWRs with instruments to measure local channel flow together with in-core neutron detectors. (Author)

  10. A Noise Robust Statistical Texture Model

    DEFF Research Database (Denmark)

    Hilger, Klaus Baggesen; Stegmann, Mikkel Bille; Larsen, Rasmus

    2002-01-01

    Appearance Models segmentation framework. This is accomplished by augmenting the model with an estimate of the covariance of the noise present in the training data. This results in a more compact model maximising the signal-to-noise ratio, thus favouring subspaces rich on signal, but low on noise......This paper presents a novel approach to the problem of obtaining a low dimensional representation of texture (pixel intensity) variation present in a training set after alignment using a Generalised Procrustes analysis.We extend the conventional analysis of training textures in the Active...

  11. Theory and Measurement of Signal-to-Noise Ratio in Continuous-Wave Noise Radar.

    Science.gov (United States)

    Stec, Bronisław; Susek, Waldemar

    2018-05-06

    Determination of the signal power-to-noise power ratio on the input and output of reception systems is essential to the estimation of their quality and signal reception capability. This issue is especially important in the case when both signal and noise have the same characteristic as Gaussian white noise. This article considers the problem of how a signal-to-noise ratio is changed as a result of signal processing in the correlation receiver of a noise radar in order to determine the ability to detect weak features in the presence of strong clutter-type interference. These studies concern both theoretical analysis and practical measurements of a noise radar with a digital correlation receiver for 9.2 GHz bandwidth. Firstly, signals participating individually in the correlation process are defined and the terms signal and interference are ascribed to them. Further studies show that it is possible to distinguish a signal and a noise on the input and output of a correlation receiver, respectively, when all the considered noises are in the form of white noise. Considering the above, a measurement system is designed in which it is possible to represent the actual conditions of noise radar operation and power measurement of a useful noise signal and interference noise signals—in particular the power of an internal leakage signal between a transmitter and a receiver of the noise radar. The proposed measurement stands and the obtained results show that it is possible to optimize with the use of the equipment and not with the complex processing of a noise signal. The radar parameters depend on its prospective application, such as short- and medium-range radar, ground-penetrating radar, and through-the-wall detection radar.

  12. Electrochemical Oxidation of Propene with a LSF15/CGO10 Electrochemical Reactor

    DEFF Research Database (Denmark)

    Ippolito, Davide; Kammer Hansen, Kent

    2014-01-01

    A porous electrochemical reactor, made of La0.85Sr0.15FeO3 (LSF) as electrode and Ce0.9Gd0.1O1.95 (CGO) as electrolyte, was studied for the electrochemical oxidation of propene over a wide range of temperatures. Polarization was found to enhance propene oxidation rate. Ce0.9Gd0.1O1.95 was used...... as infiltration material to enhance the effect of polarization on propene oxidation rate, especially at low temperatures. The influence of infiltrated material, as a function of heat treatment, on the reactor electrochemical behavior has been evaluated by using electrochemical impedance spectroscopy...... in suppressing the competing oxygen evolution reaction and promoting the oxidation of propene under polarization, with faradaic efficiencies above 70% at 250◦C. © 2014 The Electrochemical Society....

  13. Source localization analysis using seismic noise data acquired in exploration geophysics

    Science.gov (United States)

    Roux, P.; Corciulo, M.; Campillo, M.; Dubuq, D.

    2011-12-01

    Passive monitoring using seismic noise data shows a growing interest at exploration scale. Recent studies demonstrated source localization capability using seismic noise cross-correlation at observation scales ranging from hundreds of kilometers to meters. In the context of exploration geophysics, classical localization methods using travel-time picking fail when no evident first arrivals can be detected. Likewise, methods based on the intensity decrease as a function of distance to the source also fail when the noise intensity decay gets more complicated than the power-law expected from geometrical spreading. We propose here an automatic procedure developed in ocean acoustics that permits to iteratively locate the dominant and secondary noise sources. The Matched-Field Processing (MFP) technique is based on the spatial coherence of raw noise signals acquired on a dense array of receivers in order to produce high-resolution source localizations. Standard MFP algorithms permits to locate the dominant noise source by matching the seismic noise Cross-Spectral Density Matrix (CSDM) with the equivalent CSDM calculated from a model and a surrogate source position that scans each position of a 3D grid below the array of seismic sensors. However, at exploration scale, the background noise is mostly dominated by surface noise sources related to human activities (roads, industrial platforms,..), which localization is of no interest for the monitoring of the hydrocarbon reservoir. In other words, the dominant noise sources mask lower-amplitude noise sources associated to the extraction process (in the volume). Their location is therefore difficult through standard MFP technique. The Multi-Rate Adaptative Beamforming (MRABF) is a further improvement of the MFP technique that permits to locate low-amplitude secondary noise sources using a projector matrix calculated from the eigen-value decomposition of the CSDM matrix. The MRABF approach aims at cancelling the contributions of

  14. Noise source identification for ducted fan systems

    OpenAIRE

    BENNETT, GARETH; FITZPATRICK, JOHN AIDAN

    2008-01-01

    PUBLISHED Coherence based source analysis techniques can be used to identify the contribution of combustion noise in the exhaust of a jet engine and hence enable the design of noise reduction devices. However, when the combustion noise propagates in a non-linear fashion the identified contribution using ordinary coherence methods will be inaccurate. In this paper, an analysis technique to enable the contribution of linear and non-linear mechanisms to the propagated sound ...

  15. Prediction of interior noise due to random acoustic or turbulent boundary layer excitation using statistical energy analysis

    Science.gov (United States)

    Grosveld, Ferdinand W.

    1990-01-01

    The feasibility of predicting interior noise due to random acoustic or turbulent boundary layer excitation was investigated in experiments in which a statistical energy analysis model (VAPEPS) was used to analyze measurements of the acceleration response and sound transmission of flat aluminum, lucite, and graphite/epoxy plates exposed to random acoustic or turbulent boundary layer excitation. The noise reduction of the plate, when backed by a shallow cavity and excited by a turbulent boundary layer, was predicted using a simplified theory based on the assumption of adiabatic compression of the fluid in the cavity. The predicted plate acceleration response was used as input in the noise reduction prediction. Reasonable agreement was found between the predictions and the measured noise reduction in the frequency range 315-1000 Hz.

  16. Electrochemical and AFM Characterization of G-Quadruplex Electrochemical Biosensors and Applications

    Science.gov (United States)

    2018-01-01

    Guanine-rich DNA sequences are able to form G-quadruplexes, being involved in important biological processes and representing smart self-assembling nanomaterials that are increasingly used in DNA nanotechnology and biosensor technology. G-quadruplex electrochemical biosensors have received particular attention, since the electrochemical response is particularly sensitive to the DNA structural changes from single-stranded, double-stranded, or hairpin into a G-quadruplex configuration. Furthermore, the development of an increased number of G-quadruplex aptamers that combine the G-quadruplex stiffness and self-assembling versatility with the aptamer high specificity of binding to a variety of molecular targets allowed the construction of biosensors with increased selectivity and sensitivity. This review discusses the recent advances on the electrochemical characterization, design, and applications of G-quadruplex electrochemical biosensors in the evaluation of metal ions, G-quadruplex ligands, and other small organic molecules, proteins, and cells. The electrochemical and atomic force microscopy characterization of G-quadruplexes is presented. The incubation time and cations concentration dependence in controlling the G-quadruplex folding, stability, and nanostructures formation at carbon electrodes are discussed. Different G-quadruplex electrochemical biosensors design strategies, based on the DNA folding into a G-quadruplex, the use of G-quadruplex aptamers, or the use of hemin/G-quadruplex DNAzymes, are revisited. PMID:29666699

  17. Measurement of two-phase flow variables in a BWR by analysis of in-core neutron detector noise signals

    International Nuclear Information System (INIS)

    Stekelenburg, A.J.C.; Hagen, T.H.J.J. van der

    1996-01-01

    In this paper, the state of the art of the measurement of two-phase flow variables in a boiling water reactor (BWR) by analysis of in-core neutron detector noise signals is given. It is concluded that the neutronic processes involved in neutron noise are quite well understood, but that little is known about the density fluctuations in two-phase flow which are the main cause of the neutron noise. For this reason, the neutron noise measurements, like the well known two-detector velocity measurements, are still difficult to interpret. By analyzing neutron noise measurements in a natural circulation cooled BWR, it is illustrated that, once a theory on the density fluctuations is developed, two-phase flow can be monitored with a single in-core detector. (author). 70 refs, 4 figs

  18. Analysis of Individual Preferences for Tuning Noise-Reduction Algorithms

    NARCIS (Netherlands)

    Houben, Rolph; Dijkstra, Tjeerd M. H.; Dreschler, Wouter A.

    2012-01-01

    There is little research on user preference for different settings of noise reduction, especially for individual users. We therefore measured individual preferences for pairs of audio streams differing in the trade-off between noise reduction and speech distortion. A logistic probability model was

  19. Dynamic analysis of the Nova Target Chamber to assess alignment errors due to ambient noise

    International Nuclear Information System (INIS)

    McCallen, D.B.; Murray, R.C.

    1984-01-01

    We performed a study to determine the dynamic behavior of the Nova Target Chamber. We conducted a free vibration analysis to determine the natural frequencies of vibration and the corresponding modeshapes of the target chamber. Utilizing the free vibration results, we performed forced vibration analysis to predict the displacements of the chamber due to ambient vibration. The input support motion for the forced vibration analysis was defined by a white noise acceleration spectrum which was based on previous measurements of ground noise near the Nova site. A special purpose computer program was prepared to process the results of the forced vibration analysis. The program yields distances by which the lines of sight of the various laser beams miss the target as a result of ambient vibrations. We also performed additional estimates of miss distance to provide bounds on the results. A description of the finite element model of the chamber, the input spectrum, and the results of the analyses are included

  20. Synthesis, spectroscopic analysis and electrochemical performance of modified β-nickel hydroxide electrode with CuO

    Directory of Open Access Journals (Sweden)

    B. Shruthi

    2017-03-01

    Full Text Available In the present work, a modified β-nickel hydroxide (β-Ni(OH2 electrode material with CuO has been prepared using a co-precipitation method. The structure and property of the modified β-Ni(OH2 with CuO were characterized by X-ray diffraction (XRD, Fourier Transform infra-red (FT-IR, Raman and thermal gravimetric-differential thermal analysis (TG-DTA techniques. The results of the FT-IR spectroscopy and TG-DTA indicate that the modified β-Ni(OH2 electrode materials contain intercalated water molecules and anions. A pasted–type electrode was prepared using nickel hydroxide powder as the main active material on a nickel sheet as a current collector. Cyclic voltammetry (CV and Electrochemical impedance spectroscopy (EIS studies were undertaken to assess the electrochemical behavior of pure β-Ni(OH2 and modified β-Ni(OH2 electrode with CuO in a 6 M KOH electrolyte. The addition of CuO into β-nickel hydroxide was found to enhance the reversibility of the electrode reaction and also increase the separation of the oxidation current peak of the active material from the oxygen evolution current. The modified nickel hydroxide with CuO was also found to exhibit a higher proton diffusion coefficient and a lower charge transfer resistance. These findings suggest that the modified β-Ni(OH2 with CuO possesses an enhanced electrochemical response and thus can be recognized as a promising candidate for battery electrode applications.

  1. An Analysis of 1/f2 Phase Noise in Bipolar Colpitts Oscillators (With a Digression on Bipolar Differential-Pair LC Oscillators)

    DEFF Research Database (Denmark)

    Fard, A.; Andreani, Pietro

    2007-01-01

    This work presents an analysis of phase noise in the $1/f^{2}$ region displayed by both single-ended and differential bipolar Colpitts oscillators. Very accurate and rigorous symbolic phase noise expressions are derived, enabling a deeper insight into the major mechanisms of phase noise generatio......, and providing new tools for design optimization. Phase noise expressions for the cross-coupled differential-pair LC-tank oscillator are derived as well....

  2. Effects of background noise on total noise annoyance

    Science.gov (United States)

    Willshire, K. F.

    1987-01-01

    Two experiments were conducted to assess the effects of combined community noise sources on annoyance. The first experiment baseline relationships between annoyance and noise level for three community noise sources (jet aircraft flyovers, traffic and air conditioners) presented individually. Forty eight subjects evaluated the annoyance of each noise source presented at four different noise levels. Results indicated the slope of the linear relationship between annoyance and noise level for the traffic noise was significantly different from that of aircraft and of air conditioner noise, which had equal slopes. The second experiment investigated annoyance response to combined noise sources, with aircraft noise defined as the major noise source and traffic and air conditioner noise as background noise sources. Effects on annoyance of noise level differences between aircraft and background noise for three total noise levels and for both background noise sources were determined. A total of 216 subjects were required to make either total or source specific annoyance judgements, or a combination of the two, for a wide range of combined noise conditions.

  3. Analysis of log rate noise in Ontario's CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Hinds, H.W. [Dynamic Simulation and Analysis Corp., Deep River, Ontario (Canada); Banica, C.; Arguner, D. [Ontario Power Generation, Ajax, Ontario (Canada); Scharfenberg, R. [Bruce Power, Tiverton, Ontario (Canada)

    2007-07-01

    In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that the Log noise (source of Log Rate noise) was much larger for those ion chambers in the path of the moderator injection nozzles, compared to those which were not in the path. This 'extra' Log noise would then be either attenuated or amplified depending on the transfer function (time constants) of the Log Rate amplifier. It was also observed that most of the Log and Log Rate noise is independent of any other signal measured. Although all CANDU reactors in Ontario have Log and Log Rate noise, the Bruce A SDS1 system has the largest amount of Log Rate noise, because (a) its SDS1 (and RRS) ion chambers are at the top of the reactor in the path of the moderator injection nozzles, and (b) its SDS1 Log Rate amplifiers have the smallest time constants. (author)

  4. Analysis of noise pollution level in a University campus in South India

    Science.gov (United States)

    Thattai, D.; Sudarsan, J. S.; Sathyanathan, R.; Ramasamy, Visalatchi

    2017-07-01

    Noise comprises those sounds occurring around us that are not part of the environment under consideration. Noise is also a type of pollution and impacts on our health and wellness. The prevalence of noise is increasing in magnitude and severity because of growing population and urbanization. Noise pollution leads to many chronic and socially significant impacts. This study analyzes the level of noise at different points in SRM University. As the University encompasses a hospital also, it is more important to identify the sources of high noise levels and control them. As per Indian standards the desirable noise pollution for educational institutions and hospitals in daytime is 50 dbA. Noise levels were measured with a sound level meter at 19 points within the campus at three different timings (8-10 am, 12-2 pm, and 3-5 pm) over two cycles of measurements. The preliminary results show higher noise levels during morning and evening. Noise during Cycle 2 (latter half of semester) was 20% more compared to that of Cycle 1 (beginning of semester).

  5. Regression of environmental noise in LIGO data

    International Nuclear Information System (INIS)

    Tiwari, V; Klimenko, S; Mitselmakher, G; Necula, V; Drago, M; Prodi, G; Frolov, V; Yakushin, I; Re, V; Salemi, F; Vedovato, G

    2015-01-01

    We address the problem of noise regression in the output of gravitational-wave (GW) interferometers, using data from the physical environmental monitors (PEM). The objective of the regression analysis is to predict environmental noise in the GW channel from the PEM measurements. One of the most promising regression methods is based on the construction of Wiener–Kolmogorov (WK) filters. Using this method, the seismic noise cancellation from the LIGO GW channel has already been performed. In the presented approach the WK method has been extended, incorporating banks of Wiener filters in the time–frequency domain, multi-channel analysis and regulation schemes, which greatly enhance the versatility of the regression analysis. Also we present the first results on regression of the bi-coherent noise in the LIGO data. (paper)

  6. Comparative study of the microbiological corrosion among an AISI 304L and an API X65

    International Nuclear Information System (INIS)

    Diaz S, A.; Arganis J, C.; Luna C, P.; Carapia M, L.; Gonzalez F, E.

    2004-01-01

    Metallic samples of AISI 304L sensitized and API X65, were subjected to the action of an inoculated media with reductive sulphate microorganisms (SBR), carrying out electrochemical evaluations by means of the techniques of Polarization Resistance (RP), Tafel extrapolation (ET) and Electrochemical Noise (RE). The generated information was complemented with the analysis and diagnostic of the present damage in the surfaces exposed in both metals. The used electrochemical techniques allow to determine the corrosion velocities associated to each system, establishing that the uniform corrosion is not affected by the effect of the microorganisms; however, electrochemical noise, evidenced the formation of stings associated to the presence of bacteria. (Author)

  7. Comparative study of the microbiological corrosion among an AISI 304L and an API X65; Estudio comparativo de la corrosion microbiologica entre un AISI 304L y un API X65

    Energy Technology Data Exchange (ETDEWEB)

    Diaz S, A.; Arganis J, C.; Luna C, P.; Carapia M, L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gonzalez F, E. [ITT, Toluca, Estado de Mexico (Mexico)

    2004-07-01

    Metallic samples of AISI 304L sensitized and API X65, were subjected to the action of an inoculated media with reductive sulphate microorganisms (SBR), carrying out electrochemical evaluations by means of the techniques of Polarization Resistance (RP), Tafel extrapolation (ET) and Electrochemical Noise (RE). The generated information was complemented with the analysis and diagnostic of the present damage in the surfaces exposed in both metals. The used electrochemical techniques allow to determine the corrosion velocities associated to each system, establishing that the uniform corrosion is not affected by the effect of the microorganisms; however, electrochemical noise, evidenced the formation of stings associated to the presence of bacteria. (Author)

  8. Elastomeric Structural Attachment Concepts for Aircraft Flap Noise Reduction - Challenges and Approaches to Hyperelastic Structural Modeling and Analysis

    Science.gov (United States)

    Sreekantamurthy, Thammaiah; Turner, Travis L.; Moore, James B.; Su, Ji

    2014-01-01

    Airframe noise is a significant part of the overall noise of transport aircraft during the approach and landing phases of flight. Airframe noise reduction is currently emphasized under the Environmentally Responsible Aviation (ERA) and Fixed Wing (FW) Project goals of NASA. A promising concept for trailing-edge-flap noise reduction is a flexible structural element or link that connects the side edges of the deployable flap to the adjacent main-wing structure. The proposed solution is distinguished by minimization of the span-wise extent of the structural link, thereby minimizing the aerodynamic load on the link structure at the expense of increased deformation requirement. Development of such a flexible structural link necessitated application of hyperelastic materials, atypical structural configurations and novel interface hardware. The resulting highly-deformable structural concept was termed the FLEXible Side Edge Link (FLEXSEL) concept. Prediction of atypical elastomeric deformation responses from detailed structural analysis was essential for evaluating feasible concepts that met the design constraints. The focus of this paper is to describe the many challenges encountered with hyperelastic finite element modeling and the nonlinear structural analysis of evolving FLEXSEL concepts. Detailed herein is the nonlinear analysis of FLEXSEL concepts that emerged during the project which include solid-section, foamcore, hollow, extended-span and pre-stressed concepts. Coupon-level analysis performed on elastomeric interface joints, which form a part of the FLEXSEL topology development, are also presented.

  9. Reactor noise analysis based on nonlinear dynamic theory - application to power oscillation

    International Nuclear Information System (INIS)

    Suzudo, Tomoaki

    1993-01-01

    The information dimension is one of the simplest quantities that can be used to determine the asymptotic motion of the time evolution of a nonlinear system. The application of this quantity to reactor noise analysis is proposed, and the possibility of its application to power oscillation analysis is examined. The information dimension of this regime is equal to the number of independent oscillating modes, which is an intuitive physical variable. Time series data from computer experiments and experiments with an actual physical system are used for the analysis. The results indicate that the method is useful for a detailed analysis of reactor power oscillation

  10. In situ corrosion analysis of Al-Zn-In-Mg-Ti-Ce sacrificial anode alloy

    International Nuclear Information System (INIS)

    Ma Jingling; Wen Jiuba; Zhai Wenxia; Li Quanan

    2012-01-01

    The corrosion behaviour of Al-5Zn-0.02In-1Mg-0.05Ti-0.5Ce (wt.%) alloy has been investigated by immersion test, scanning electron microscopy, energy dispersive X-ray detector, electrochemical impedance spectroscopy and electrochemical noise. The results show that there exist different corrosion types of the alloy in 3.5% NaCl solution with the immersion time. At the initial stage of immersion, pitting due to the precipitates predominates the corrosion with a typical inductive loop at low frequencies in electrochemical impedance spectroscopy. The major precipitates of the alloy are MgZn 2 and Al 2 CeZn 2 particles. The corrosion potentials of the bulk MgZn 2 and Al 2 CeZn 2 alloys are negative with respect to that of α-Al, so the MgZn 2 and Al 2 CeZn 2 precipitates can act as activation centre and cause the pitting. In the late corrosion, a relative uniform corrosion predominates the corrosion process controlled by the dissolution/precipitation of the In ions and characterized by a capacitive loop at medium-high frequencies in electrochemical impedance spectroscopy. The potential noise of the pitting shows larger amplitude fluctuation and lower frequency, but the potential noise of the uniform corrosion occurs with smaller amplitude fluctuation and higher frequency.

  11. Utility experience in reactor noise analysis in German LWRs

    International Nuclear Information System (INIS)

    Schuette, A.; Weingarten, J.; Wach, D.

    1988-01-01

    Reactor noise analysis has a long history in Fed. Rep. of Germany. Since the early 60ies it was directed to early fault, malfunction and anomaly detection in nuclear power plants. When successful diagnoses showed the high potential and benefits including economic and safety aspects, also the utilities began to have a vivid concern in application of the developed methods and systems. The know-how transfer from specialized teams to the onsite personnel as well as the development of more ''intelligent'' online systems are important present and future tasks for further improvement of their efficiency. The diagnostic group of GRS is active in both fields and has close cooperation with several utilities to achieve these objectives. Modern signal processing equipment and access to a comprehensive knowledge base stored in data banks are provided by the data analysis center of GRS. The available capabilities are described and examples of analysis results within the cooperation utilities/GRS are given. (author)

  12. Wind turbine airfoil design method with low noise and experimental analysis

    DEFF Research Database (Denmark)

    Wang, Quan; Chen, Jin; Cheng, Jiangtao

    2015-01-01

    In order to study the noise characteristic of wind turbine airfoils, the airfoil optimal design mathematic model was built based on airfoil functional integrated theory and noise calculated model. The new optimized objective function of maximizing lift/drag to noise was developed on the design......, though there is a certain difference between the theory results and experiment data. Compared with NACA-64-618 airfoil, the CQU-DTU-B18 airfoil exhibits lower noise, which validates the feasibility of this design method. It is a guide to design wind turbine airfoil with lower noise and to reduce airfoil...

  13. Noise Scaling and Community Noise Metrics for the Hybrid Wing Body Aircraft

    Science.gov (United States)

    Burley, Casey L.; Brooks, Thomas F.; Hutcheson, Florence V.; Doty, Michael J.; Lopes, Leonard V.; Nickol, Craig L.; Vicroy, Dan D.; Pope, D. Stuart

    2014-01-01

    An aircraft system noise assessment was performed for the hybrid wing body aircraft concept, known as the N2A-EXTE. This assessment is a result of an effort by NASA to explore a realistic HWB design that has the potential to substantially reduce noise and fuel burn. Under contract to NASA, Boeing designed the aircraft using practical aircraft design princip0les with incorporation of noise technologies projected to be available in the 2020 timeframe. NASA tested 5.8% scale-mode of the design in the NASA Langley 14- by 22-Foot Subsonic Tunnel to provide source noise directivity and installation effects for aircraft engine and airframe configurations. Analysis permitted direct scaling of the model-scale jet, airframe, and engine shielding effect measurements to full-scale. Use of these in combination with ANOPP predictions enabled computations of the cumulative (CUM) noise margins relative to FAA Stage 4 limits. The CUM margins were computed for a baseline N2A-EXTE configuration and for configurations with added noise reduction strategies. The strategies include reduced approach speed, over-the-rotor line and soft-vane fan technologies, vertical tail placement and orientation, and modified landing gear designs with fairings. Combining the inherent HWB engine shielding by the airframe with added noise technologies, the cumulative noise was assessed at 38.7 dB below FAA Stage 4 certification level, just 3.3 dB short of the NASA N+2 goal of 42 dB. This new result shows that the NASA N+2 goal is approachable and that significant reduction in overall aircraft noise is possible through configurations with noise reduction technologies and operational changes.

  14. Maximizing noise energy for noise-masking studies.

    Science.gov (United States)

    Jules Étienne, Cédric; Arleo, Angelo; Allard, Rémy

    2017-08-01

    Noise-masking experiments are widely used to investigate visual functions. To be useful, noise generally needs to be strong enough to noticeably impair performance, but under some conditions, noise does not impair performance even when its contrast approaches the maximal displayable limit of 100 %. To extend the usefulness of noise-masking paradigms over a wider range of conditions, the present study developed a noise with great masking strength. There are two typical ways of increasing masking strength without exceeding the limited contrast range: use binary noise instead of Gaussian noise or filter out frequencies that are not relevant to the task (i.e., which can be removed without affecting performance). The present study combined these two approaches to further increase masking strength. We show that binarizing the noise after the filtering process substantially increases the energy at frequencies within the pass-band of the filter given equated total contrast ranges. A validation experiment showed that similar performances were obtained using binarized-filtered noise and filtered noise (given equated noise energy at the frequencies within the pass-band) suggesting that the binarization operation, which substantially reduced the contrast range, had no significant impact on performance. We conclude that binarized-filtered noise (and more generally, truncated-filtered noise) can substantially increase the energy of the noise at frequencies within the pass-band. Thus, given a limited contrast range, binarized-filtered noise can display higher energy levels than Gaussian noise and thereby widen the range of conditions over which noise-masking paradigms can be useful.

  15. Assessment and prediction of wind turbine noise

    International Nuclear Information System (INIS)

    Lowson, M.V.

    1993-01-01

    The significance of basic aerodynamic noise sources for wind turbine noise are assessed, using information on the aero-acoustic mechanisms of other rotors, which have been studied in depth for many years. From the analysis, areas of potential improvement in wind turbine noise prediction are defined. Suggestions are made for approaches to wind turbine noise control which separate the noise problems at cut-in from those at rated power. Some of these offer the possibility of noise reduction without unfavourable effects on performance. Based on this analysis, a new model for prediction of wind turbine noise is presented and comparisons made between prediction and experiment. The model is based on well established aeroacoustic theory and published laboratory data for the two principal sources, inflow turbulence and boundary layer trailing edge interaction. The new method gives good agreement with experiment with the case studied so far. Parametric trends and sensitivities for the model are presented. Comparisons with previous prediction methods are also given. A consequence of the new model is to put more emphasis on boundary layer trailing edge interaction as a noise source. There are prospects for reducing noise from this source detail changes to the wind turbine design. (author)

  16. MIMO scheme performance and detection in epsilon noise

    OpenAIRE

    Stepanov, Sander

    2006-01-01

    New approach for analysis and decoding MIMO signaling is developed for usual model of nongaussion noise consists of background and impulsive noise named epsilon - noise. It is shown that non-gaussion noise performance significantly worse than gaussion ones. Stimulation results strengthen out theory. Robust in statistical sense detection rule is suggested for such kind of noise features much best robust detector performance than detector designed for Gaussian noise in impulsive environment and...

  17. Active Noise Control for Dishwasher noise

    Science.gov (United States)

    Lee, Nokhaeng; Park, Youngjin

    2016-09-01

    The dishwasher is a useful home appliance and continually used for automatically washing dishes. It's commonly placed in the kitchen with built-in style for practicality and better use of space. In this environment, people are easily exposed to dishwasher noise, so it is an important issue for the consumers, especially for the people living in open and narrow space. Recently, the sound power levels of the noise are about 40 - 50 dBA. It could be achieved by removal of noise sources and passive means of insulating acoustical path. For more reduction, such a quiet mode with the lower speed of cycle has been introduced, but this deteriorates the washing capacity. Under this background, we propose active noise control for dishwasher noise. It is observed that the noise is propagating mainly from the lower part of the front side. Control speakers are placed in the part for the collocation. Observation part of estimating sound field distribution and control part of generating the anti-noise are designed for active noise control. Simulation result shows proposed active noise control scheme could have a potential application for dishwasher noise reduction.

  18. Speckle noise reduction technique for Lidar echo signal based on self-adaptive pulse-matching independent component analysis

    Science.gov (United States)

    Xu, Fan; Wang, Jiaxing; Zhu, Daiyin; Tu, Qi

    2018-04-01

    Speckle noise has always been a particularly tricky problem in improving the ranging capability and accuracy of Lidar system especially in harsh environment. Currently, effective speckle de-noising techniques are extremely scarce and should be further developed. In this study, a speckle noise reduction technique has been proposed based on independent component analysis (ICA). Since normally few changes happen in the shape of laser pulse itself, the authors employed the laser source as a reference pulse and executed the ICA decomposition to find the optimal matching position. In order to achieve the self-adaptability of algorithm, local Mean Square Error (MSE) has been defined as an appropriate criterion for investigating the iteration results. The obtained experimental results demonstrated that the self-adaptive pulse-matching ICA (PM-ICA) method could effectively decrease the speckle noise and recover the useful Lidar echo signal component with high quality. Especially, the proposed method achieves 4 dB more improvement of signal-to-noise ratio (SNR) than a traditional homomorphic wavelet method.

  19. FABRICATION AND CHARACTERIZATION OF POLYANILINE-GRAPHENE COMPOSITE AS ELECTRODE IN ELECTROCHEMICAL CAPACITOR

    Directory of Open Access Journals (Sweden)

    H. Adelkhani

    2016-06-01

    Full Text Available In this study, polyaniline-graphene composites with different nano-structures are synthesized and the behaviour of the obtained composites serving as electrode materials in electrochemical capacitors is studied. The morphology, crystal structure, and thermal stability of the composites are examined using scanning electron microscopy (SEM, X-ray diffraction (XRD, and Thermal gravimetric analysis (TGA. Electrochemical properties are characterized by cyclic voltammetry (CV. According to the results, the obtained composites show different crystal structures and different thermal stabilities, and consequently different electrochemical capacities, when used as electrodes in electrochemical capacitors. A nano-fibre composite is shown to have a good degree of crystallization, 5.17% water content, 637oC degradation onset temperature, and 379 Fg-1 electrochemical capacity.

  20. Interpretation of incore noise measurements in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van

    1982-01-01

    A survey is given of the main incentives for power reactor noise research and the differences and similarities of noise in power and zero power systems are touched on. The basic characteristics of the adjoint method in reactor noise theory are treated. The detector adjoint functions describe the transfer functions between spatially distributed noise sources and a (neutron or gamma) detector. In particular, the spatial dependence of these functions explains the 'local' and 'global' effects in BWR noise measurements. By including thermal hydraulic feedback effects in the adjoint analysis, it is shown that the common idea of a dominant global effect at low frequencies which should result in point kinetic behaviour, is erroneous. The same analysis provides a method for nonperturbing on-line measurement of the reactor transfer function, which is demonstrated by results from measurements on a BWR in the Netherlands. In the final part of the paper some ideas are given for further research in the field of BWR noise. (author)

  1. Interpretation of incore noise measurements in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van

    1983-01-01

    A survey is given of the main incentives for power reactor noise research, and the differences and similarities of noise in power and zero power systems are shown. After a short outline of historical developments the basic characteristics of the adjoint method in reactor noise theory are dealt with. The detector adjoint functions describe the transfer functions between spatially distributed noise sources and a (neutron or gamma) detector. In particular, the spatial dependence of these functions explains the 'local' and 'global' effects in BWR noise measurements. By including thermal hydraulic feedback effects in the adjoint analysis, it is shown that the common idea of a dominant global effect at low frequencies, which should result in point kinetic behaviour, is erroneous. The same analysis provides a method for nonperturbing on-line measurements on a BWR in The Netherlands. In the final part of the paper some ideas are given for further research in the field of BWR noise. (author)

  2. Electrochemical generation and storage of electrical energy; Production et stockage electrochimiques de l'energie electrique

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, J.F.

    2005-07-01

    Electrochemical systems have the remarkable property of being able to convert chemical energy into electrical energy and vice-versa, and this, in conditions close to the thermodynamical reversibility, without any pollutant and noise emissions, and without the need of heavy maintenance. These systems can find various applications in the different domains of the economical life, in particular in the transportation sector. Depending on the application in concern, the batteries, fuel cells and super-capacitors are more or less well-adapted and the choice of a given, or of a combination of technologies must be made with respect to the final objective of the application. This document presents the history, principle, electromotive force, capacity, power, and cyclability of closed electrochemical generators (batteries and capacitors). It presents also the principle and characteristics of open systems (fuel cells and redox systems). (J.S.)

  3. Review of noise in neonatal intensive care units - regional analysis

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Abril, A [National Technological University, Regional Bioengineering Institute, Mendoza (Argentina); Terron, A; Boschi, C [National Technological University, Regional Bioengineering Institute, Mendoza (Argentina); Gomez, M [National Technological University, La Rioja (Argentina)

    2007-11-15

    This work is about the problem of noise in neonatal incubators and in the environment in the neonatal intensive care units. Its main objective is to analyse the impact of noise in hospitals of Mendoza and La Rioja. Methodology: The measures were taken in different moments in front of higher or lower severity level in the working environment. It is shown that noise produces severe damages and changes in the behaviour and the psychological status of the new born babies. Results: The noise recorded inside the incubators and the neonatal intensive care units together have many components but the noise of motors, opening and closing of access gates have been considered the most important ones. Values above 60 db and and up to 120 db in some cases were recorded, so the need to train the health staff in order to manage the new born babies, the equipment and the instruments associated with them very carefully is revealed.

  4. Review of noise in neonatal intensive care units - regional analysis

    International Nuclear Information System (INIS)

    Alvarez Abril, A; Terron, A; Boschi, C; Gomez, M

    2007-01-01

    This work is about the problem of noise in neonatal incubators and in the environment in the neonatal intensive care units. Its main objective is to analyse the impact of noise in hospitals of Mendoza and La Rioja. Methodology: The measures were taken in different moments in front of higher or lower severity level in the working environment. It is shown that noise produces severe damages and changes in the behaviour and the psychological status of the new born babies. Results: The noise recorded inside the incubators and the neonatal intensive care units together have many components but the noise of motors, opening and closing of access gates have been considered the most important ones. Values above 60 db and and up to 120 db in some cases were recorded, so the need to train the health staff in order to manage the new born babies, the equipment and the instruments associated with them very carefully is revealed

  5. Identification of nuclear reactor characteristics by the reactor noise analysis

    International Nuclear Information System (INIS)

    Yashima, Hideyuki

    1980-01-01

    Reactor noise analysis method was applied to TRIGA II Research Reactor (Atomic Research Laboratory, Musashi Institute of Technology) and computed power spectral density (PSD) from the CIC current record. PSD has provided many valuable informations regarding to the reactor kinetics, including the effect of control rods vibration. Another information of neutron physics parameters were obtained and this result was compared with the parameter which was formerly measured by the Feynman-α experiment. Through these experiments we could find overall frequency characteristics of TRIGA II Reactor. (author)

  6. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  7. Efficient electrochemical degradation of multiwall carbon nanotubes.

    Science.gov (United States)

    Reipa, Vytas; Hanna, Shannon K; Urbas, Aaron; Sander, Lane; Elliott, John; Conny, Joseph; Petersen, Elijah J

    2018-07-15

    As the production mass of multiwall carbon nanotubes (MWCNT) increases, the potential for human and environmental exposure to MWCNTs may also increase. We have shown that exposing an aqueous suspension of pristine MWCNTs to an intense oxidative treatment in an electrochemical reactor, equipped with an efficient hydroxyl radical generating Boron Doped Diamond (BDD) anode, leads to their almost complete mineralization. Thermal optical transmittance analysis showed a total carbon mass loss of over two orders of magnitude due to the electrochemical treatment, a result consistent with measurements of the degraded MWCNT suspensions using UV-vis absorbance. Liquid chromatography data excludes substantial accumulation of the low molecular weight reaction products. Therefore, up to 99% of the initially suspended MWCNT mass is completely mineralized into gaseous products such as CO 2 and volatile organic carbon. Scanning electron microscopy (SEM) images show sporadic opaque carbon clusters suggesting the remaining nanotubes are transformed into structure-less carbon during their electrochemical mineralization. Environmental toxicity of pristine and degraded MWCNTs was assessed using Caenorhabditis elegans nematodes and revealed a major reduction in the MWCNT toxicity after treatment in the electrochemical flow-by reactor. Published by Elsevier B.V.

  8. NEIGHBOURHOOD ANALYSIS OF THE IMPACT CAUSED BY THE NOISE IN A WEIGHT TRAINING ACADEMY OF A HAIR SALON

    Directory of Open Access Journals (Sweden)

    Diani Fernanda Silva

    2011-08-01

    Full Text Available The analysis of neighborhood impact associated to noise is very important to the living and working environments independently of our activity. The legislative Brazilian norm NBR 10151 imposes limits of noise produced by business establishments. The maximum values of acoustic comfort on the surrounding community are 60 dB at daytime and 55 dB at nighttime. Environments as gym, perform music at high intensity as an incentive to practice physical exercises, however, excessive continuous noise produced by sound equipment may cause annoyance for adjacent environments, as a hairdresser analyzed in this study. Among the complaints of the professionals are digestive disorders, headaches, increase disturbances of concentration, dizziness, sleeping disturbs, anxiety, fatigue and stress. Inevitably, noise is a result of almost all our activities. We could improve our quality of life by avoiding the hazardous noise.

  9. Principal component analysis of 1/fα noise

    International Nuclear Information System (INIS)

    Gao, J.B.; Cao Yinhe; Lee, J.-M.

    2003-01-01

    Principal component analysis (PCA) is a popular data analysis method. One of the motivations for using PCA in practice is to reduce the dimension of the original data by projecting the raw data onto a few dominant eigenvectors with large variance (energy). Due to the ubiquity of 1/f α noise in science and engineering, in this Letter we study the prototypical stochastic model for 1/f α processes--the fractional Brownian motion (fBm) processes using PCA, and find that the eigenvalues from PCA of fBm processes follow a power-law, with the exponent being the key parameter defining the fBm processes. We also study random-walk-type processes constructed from DNA sequences, and find that the eigenvalue spectrum from PCA of those random-walk processes also follow power-law relations, with the exponent characterizing the correlation structures of the DNA sequence. In fact, it is observed that PCA can automatically remove linear trends induced by patchiness in the DNA sequence, hence, PCA has a similar capability to the detrended fluctuation analysis. Implications of the power-law distributed eigenvalue spectrum are discussed

  10. Measurement and analysis of the noise radiated by low Mach numbers centrifugal blowers

    Science.gov (United States)

    Yeager, D. M.; Lauchle, G. C.

    1987-11-01

    The broad band, aerodynamically generated noise in low tip-speed Mach number, centrifugal air moving devices is investigated. An interdisciplinary approach was taken which involved investigation of the aerodynamic and acoustic fields, and their mutual relationship. The noise generation process was studied using two experimental vehicles: (1) a scale model of a homologous family of centrifugal blowers typical of those used to cool computer and business equipment, and (2) a single blade from a centrifugal blower impeller which was placed in a known, controllable flow field. The radiation characteristics of the model blower were investigated by measuring the acoustic intensity distribution near the blower inlet and comparing it with the intensity near the inlet to an axial flow fan. Aerodynamic studies of the flow field in the inlet and at the discharge to the rotating impeller were used to assess the mean flow distribution through the impeller blade channels and to identify regions of excessive turbulence near the rotating blade row. New frequency-domain expressions for the correlation area and dipole source strength per unit area on a surface immersed in turbulence were developed which can be used to characterize the noise generation process over a rigid surface immersed in turbulence. An investigation of the noise radiated from the single, isolated airfoil (impeller blade) was performed using modern correlation and spectral analysis techniques.

  11. Nanomaterials in electrochemical biosensors for pesticide detection: advances and challenges in food analysis

    International Nuclear Information System (INIS)

    Arduini, Fabiana; Moscone, Danila; Cinti, Stefano; Scognamiglio, Viviana

    2016-01-01

    This overview (with 114 refs.) covers the progress made between 2010 and 2015 in the field of nanomaterial based electrochemical biosensors for pesticides in food. Its main focus is on strategies to analyze real samples. The review first gives a short introduction into the most often used bio recognition elements. These include (a) enzymes (resulting in inhibition-based and direct catalytic biosensors), (b) antibodies (resulting in immunosensors), and (c) aptamers (resulting in aptasensors). The next main section covers the various kinds of nanomaterials for use in biosensors and includes carbonaceous species (carbon nanotubes, graphene, carbon black and others), and non-carbonaceous species in the form of nanoparticles, rods, or porous materials. Aspects of sample treatment and real sample analysis are treated next before discussing vanguard technologies in tailor-made food analysis. (author)

  12. Reactor noise analysis by statistical pattern recognition methods

    International Nuclear Information System (INIS)

    Howington, L.C.; Gonzalez, R.C.

    1976-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis is presented. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, updating, and data compacting capabilities. System design emphasizes control of the false-alarm rate. Its abilities to learn normal patterns, to recognize deviations from these patterns, and to reduce the dimensionality of data with minimum error were evaluated by experiments at the Oak Ridge National Laboratory (ORNL) High-Flux Isotope Reactor. Power perturbations of less than 0.1 percent of the mean value in selected frequency ranges were detected by the pattern recognition system

  13. Noise Considerations in Resistance Bridges

    DEFF Research Database (Denmark)

    Diamond, Joseph M.

    1963-01-01

    A signal-to-noise analysis is made of the Wheatstone bridge, where the unknown and standard resistors may be at different temperatures, a situation which occurs in resistance thermometry. The limiting condition is assumed to be dissipation in the unknown resistor. It is shown that the ratio arms...... thermometry, where the noise in the unknown resistor will predominate strongly. An impedance step-up device (transformer or tuned circuit) is valuable in raising the bridge signal and noise level above the noise of the first amplifier tube. However, as the step-up ratio is increased, two counterfactors appear....... With certain assumptions about the noise and grid current of the first tube it is found that the equivalent temperature of a unity ratio (Mueller) bridge used for liquid helium measurements may be 400°K....

  14. Diagnosis methods based on noise analysis at Cernavoda NPP, Romania

    International Nuclear Information System (INIS)

    Banica, Constantin; Dobrea, Dumitru

    1999-01-01

    This paper describes a recent noise analysis of the neutronic signals provided by in-core flux detectors (ICFD) and ion chambers (IC). This analysis is part of on-going program developed for Unit 1 of the Cernavoda NPP, Romania, with the following main objectives: - prediction of detector failures based on pattern recognition; - determination of fast excursions from steady states; - detection of abnormal mechanical vibrations in the reactor core. The introduction presents briefly the reactor, the location of ICFD's and IC's. The second section presents the data acquisition systems and their capabilities. The paper continues with a brief presentation of the numerical methods used for analysis (section 3). The most significant results can be found in section 4, while section 5 concludes about useful information that can be obtained from the neutronic signals at high power steady-state operation. (authors)

  15. Electrochemical redox processes involving soluble cerium species

    International Nuclear Information System (INIS)

    Arenas, L.F.; Ponce de León, C.; Walsh, F.C.

    2016-01-01

    Highlights: • The relevance of cerium in laboratory and industrial electrochemistry is considered. • The history of fundamental electrochemical studies and applications is considered. • The chemistry, redox thermodynamics and electrode kinetics of cerium are summarised. • The uses of cerium ions in synthesis, energy storage, analysis and environmental treatment are illustrated. • Research needs and development perspectives are discussed. - Abstract: Anodic oxidation of cerous ions and cathodic reduction of ceric ions, in aqueous acidic solutions, play an important role in electrochemical processes at laboratory and industrial scale. Ceric ions, which have been used for oxidation of organic wastes and off-gases in environmental treatment, are a well-established oxidant for indirect organic synthesis and specialised cleaning processes, including oxide film removal from tanks and process pipework in nuclear decontamination. They also provide a classical reagent for chemical analysis in the laboratory. The reversible oxidation of cerous ions is an important reaction in the positive compartment of various redox flow batteries during charge and discharge cycling. A knowledge of the thermodynamics and kinetics of the redox reaction is critical to an understanding of the role of cerium redox species in these applications. Suitable choices of electrode material (metal or ceramic; coated or uncoated), geometry/structure (2-or 3-dimensional) and electrolyte flow conditions (hence an acceptable mass transport rate) are critical to achieving effective electrocatalysis, a high performance and a long lifetime. This review considers the electrochemistry of soluble cerium species and their diverse uses in electrochemical technology, especially for redox flow batteries and mediated electrochemical oxidation.

  16. Development of a noise annoyance sensitivity scale

    Science.gov (United States)

    Bregman, H. L.; Pearson, R. G.

    1972-01-01

    Examining the problem of noise pollution from the psychological rather than the engineering view, a test of human sensitivity to noise was developed against the criterion of noise annoyance. Test development evolved from a previous study in which biographical, attitudinal, and personality data was collected on a sample of 166 subjects drawn from the adult community of Raleigh. Analysis revealed that only a small subset of the data collected was predictive of noise annoyance. Item analysis yielded 74 predictive items that composed the preliminary noise sensitivity test. This was administered to a sample of 80 adults who later rate the annoyance value of six sounds (equated in terms of peak sound pressure level) presented in a simulated home, living-room environment. A predictive model involving 20 test items was developed using multiple regression techniques, and an item weighting scheme was evaluated.

  17. Mechanical surveillance of the internal structures on the French PWRs by noise analysis

    International Nuclear Information System (INIS)

    Puyal, C.

    1983-01-01

    In service observation of structures, materials and systems in PWRs is one of the major preoccupations of EDF. Methods and means have been developed and put into service in order to achieve this goal. This paper deals with the surveillance of primary systems, using the technique of noise analysis [fr

  18. Analysis of power tiller noise using diesel-biodiesel fuel blends

    OpenAIRE

    N Keramat Siavash; Gh Najafi; S. R Hassan Beigi Bidgoli; B Ghobadian

    2015-01-01

    Introduction: There are several sources of noise in an industrial and agriculture environment. Machines with rotating or reciprocating engines are sound-producing sources. Also, the audio signal can be analyzed to discover how well a machine operates. Diesel engines complex noise SPL and sound frequency content both strongly depend on fuel combustion, which produces the so-called combustion noise. Actually, the unpleasant sound signature of diesel engines is due to the harsh and irregular sel...

  19. A trade-off analysis design tool. Aircraft interior noise-motion/passenger satisfaction model

    Science.gov (United States)

    Jacobson, I. D.

    1977-01-01

    A design tool was developed to enhance aircraft passenger satisfaction. The effect of aircraft interior motion and noise on passenger comfort and satisfaction was modelled. Effects of individual aircraft noise sources were accounted for, and the impact of noise on passenger activities and noise levels to safeguard passenger hearing were investigated. The motion noise effect models provide a means for tradeoff analyses between noise and motion variables, and also provide a framework for optimizing noise reduction among noise sources. Data for the models were collected onboard commercial aircraft flights and specially scheduled tests.

  20. An analysis of background noise in selected canyons of Los Alamos County

    Energy Technology Data Exchange (ETDEWEB)

    Huchton, K.; Koch, S.W.; Robinson, R.

    1997-10-01

    The authors recorded background noise levels in six canyons within Los Alamos County in order to establish a baseline for future comparisons and to discover what noises animals are exposed to. Noise level measurements were taken within each canyon, beginning at an established starting point and at one-mile intervals up to four miles. The primary source of noise above 55 dBA was vehicular traffic. One clap of thunder provided the highest recorded noise level (76 dBA). In general, the level of noise, once away from highways and parking lots, was well below 60 dBA.

  1. Modification of computational auditory scene analysis (CASA) for noise-robust acoustic feature

    Science.gov (United States)

    Kwon, Minseok

    While there have been many attempts to mitigate interferences of background noise, the performance of automatic speech recognition (ASR) still can be deteriorated by various factors with ease. However, normal hearing listeners can accurately perceive sounds of their interests, which is believed to be a result of Auditory Scene Analysis (ASA). As a first attempt, the simulation of the human auditory processing, called computational auditory scene analysis (CASA), was fulfilled through physiological and psychological investigations of ASA. CASA comprised of Zilany-Bruce auditory model, followed by tracking fundamental frequency for voice segmentation and detecting pairs of onset/offset at each characteristic frequency (CF) for unvoiced segmentation. The resulting Time-Frequency (T-F) representation of acoustic stimulation was converted into acoustic feature, gammachirp-tone frequency cepstral coefficients (GFCC). 11 keywords with various environmental conditions are used and the robustness of GFCC was evaluated by spectral distance (SD) and dynamic time warping distance (DTW). In "clean" and "noisy" conditions, the application of CASA generally improved noise robustness of the acoustic feature compared to a conventional method with or without noise suppression using MMSE estimator. The intial study, however, not only showed the noise-type dependency at low SNR, but also called the evaluation methods in question. Some modifications were made to capture better spectral continuity from an acoustic feature matrix, to obtain faster processing speed, and to describe the human auditory system more precisely. The proposed framework includes: 1) multi-scale integration to capture more accurate continuity in feature extraction, 2) contrast enhancement (CE) of each CF by competition with neighboring frequency bands, and 3) auditory model modifications. The model modifications contain the introduction of higher Q factor, middle ear filter more analogous to human auditory system

  2. Functionalized Solid Electrodes for Electrochemical Biosensing of Purine Nucleobases and Their Analogues: A Review

    Science.gov (United States)

    Sharma, Vimal Kumar; Jelen, Frantisek; Trnkova, Libuse

    2015-01-01

    Interest in electrochemical analysis of purine nucleobases and few other important purine derivatives has been growing rapidly. Over the period of the past decade, the design of electrochemical biosensors has been focused on achieving high sensitivity and efficiency. The range of existing electrochemical methods with carbon electrode displays the highest rate in the development of biosensors. Moreover, modification of electrode surfaces based on nanomaterials is frequently used due to their extraordinary conductivity and surface to volume ratio. Different strategies for modifying electrode surfaces facilitate electron transport between the electrode surface and biomolecules, including DNA, oligonucleotides and their components. This review aims to summarize recent developments in the electrochemical analysis of purine derivatives, as well as discuss different applications. PMID:25594595

  3. Functionalized Solid Electrodes for Electrochemical Biosensing of Purine Nucleobases and Their Analogues: A Review

    Directory of Open Access Journals (Sweden)

    Vimal Kumar Sharma

    2015-01-01

    Full Text Available Interest in electrochemical analysis of purine nucleobases and few other important purine derivatives has been growing rapidly. Over the period of the past decade, the design of electrochemical biosensors has been focused on achieving high sensitivity and efficiency. The range of existing electrochemical methods with carbon electrode displays the highest rate in the development of biosensors. Moreover, modification of electrode surfaces based on nanomaterials is frequently used due to their extraordinary conductivity and surface to volume ratio. Different strategies for modifying electrode surfaces facilitate electron transport between the electrode surface and biomolecules, including DNA, oligonucleotides and their components. This review aims to summarize recent developments in the electrochemical analysis of purine derivatives, as well as discuss different applications.

  4. Fractal characterization for noise signal validation in power reactors

    International Nuclear Information System (INIS)

    Aguilar Martinez, Omar

    2003-01-01

    Up to now, a great variety of methods is used for the dynamical characterization of different components of Nuclear Power Plants (NPPs). With this aim, time and spectral analysis are usually considered, and different tools of non-stationary and non-gaussian analysis are also presented. When applying non-lineal dynamics theory for noise signal validation purposes in power reactors, the extraction of fractal echoes plays a main role. Fractal characterization for noise signal validation purposes can be integrated to the task of processing and acquisition of time signals in noise (fluctuation parameters) analysis systems. The possibility of discrimination between deterministic chaotic signals and pure noise signals has been incorporated, as a complement; to noise signals analysis in normal and anomalous operational conditions in NPPs using a fractal approach. In this work the detailed analysis of a neutronic sensor response is considered and the fractal characterization of its dynamics state (i.e. sensor line) for noise signal classification, it is presented. The experiment from where the time series (signals) were obtained, was carried out at the Research Reactor of the Technical University of Budapest, Hungary, during a model experiment for ageing process study of in-core neutron detectors (author)

  5. Electrochemical impedance spectroscopy analysis of a thin polymer film-based micro-direct methanol fuel cell

    Science.gov (United States)

    Schulz, Tobias; Weinmüller, Christian; Nabavi, Majid; Poulikakos, Dimos

    A single cell micro-direct methanol fuel cell (micro-DMFC) was investigated using electrochemical impedance spectroscopy. The electrodes consisted of thin, flexible polymer (SU8) film microchannel structures fabricated in-house using microfabrication techniques. AC impedance spectroscopy was used to separate contributions to the overall cell polarization from the anode, cathode and membrane. A clear distinction between the different electrochemical phenomena occurring in the micro-DMFC, especially the distinction between double layer charging and Faradaic reactions was shown. The effect of fuel flow rate, temperature, and anode flow channel structure on the impedance of the electrode reactions and membrane/electrode double layer charging were investigated. Analysis of impedance data revealed that the performance of the test cell was largely limited by the presence of intermediate carbon monoxide in the anode reaction. Higher temperatures increase cell performance by enabling intermediate CO to be oxidized at much higher rates. The results also revealed that serpentine anode flow microchannels show a lower tendency to intermediate CO coverage and a more stable cell behavior than parallel microchannels.

  6. Development of a pilot size of electrochemical flushing equipment for radioactive soil and concrete

    International Nuclear Information System (INIS)

    Kim, Gye Nam; Moon, Jei Kwon; Choi, Wang Kyu; Yang, Byeong Il; Shon, Jong Sik; Hong, Dae Seok

    2010-01-01

    A pilot size of electrochemical flushing equipment will be manufactured suitable to the contamination characteristics of radioactive soil and concrete stored in KAERI radioactive waste storage. An optimal reagent and an optimal decontamination conditions should be decided through many experiments. - Contamination characterises analysis of TRIGA radioactive soil and concrete - Manufacture of pilot-scale electrochemical flushing equipment - Manufacture and improvement of suitable electrochemical flushing equipment for contamination characteristics in pilot size - Decontamination experiments of electrochemical flushing equipment in a pilot scale

  7. Application of ionic liquids in electrochemical sensing systems.

    Science.gov (United States)

    Shiddiky, Muhammad J A; Torriero, Angel A J

    2011-01-15

    Since 1992, when the room temperature ionic liquids (ILs) based on the 1-alkyl-3-methylimidazolium cation were reported to provide an attractive combination of an electrochemical solvent and electrolyte, ILs have been widely used in electrodeposition, electrosynthesis, electrocatalysis, electrochemical capacitor, and lithium batteries. However, it has only been in the last few years that electrochemical biosensors based on carbon ionic liquid electrodes (CILEs) and IL-modified macrodisk electrodes have been reported. However, there are still a lot of challenges in achieving IL-based sensitive, selective, and reproducible biosensors for high speed analysis of biological and environmental compounds of interest. This review discusses the principles of operation of electrochemical biosensors based on CILEs and IL/composite-modified macrodisk electrodes. Subsequently, recent developments and major strategies for enhancing sensing performance are discussed. Key challenges and opportunities of IL-based biosensors to further development and use are considered. Emphasis is given to direct electron-transfer reaction and electrocatalysis of hemeproteins and enzyme-modified composite electrodes. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Spatiotemporal noise covariance estimation from limited empirical magnetoencephalographic data

    International Nuclear Information System (INIS)

    Jun, Sung C; Plis, Sergey M; Ranken, Doug M; Schmidt, David M

    2006-01-01

    The performance of parametric magnetoencephalography (MEG) and electroencephalography (EEG) source localization approaches can be degraded by the use of poor background noise covariance estimates. In general, estimation of the noise covariance for spatiotemporal analysis is difficult mainly due to the limited noise information available. Furthermore, its estimation requires a large amount of storage and a one-time but very large (and sometimes intractable) calculation or its inverse. To overcome these difficulties, noise covariance models consisting of one pair or a sum of multi-pairs of Kronecker products of spatial covariance and temporal covariance have been proposed. However, these approaches cannot be applied when the noise information is very limited, i.e., the amount of noise information is less than the degrees of freedom of the noise covariance models. A common example of this is when only averaged noise data are available for a limited prestimulus region (typically at most a few hundred milliseconds duration). For such cases, a diagonal spatiotemporal noise covariance model consisting of sensor variances with no spatial or temporal correlation has been the common choice for spatiotemporal analysis. In this work, we propose a different noise covariance model which consists of diagonal spatial noise covariance and Toeplitz temporal noise covariance. It can easily be estimated from limited noise information, and no time-consuming optimization and data-processing are required. Thus, it can be used as an alternative choice when one-pair or multi-pair noise covariance models cannot be estimated due to lack of noise information. To verify its capability we used Bayesian inference dipole analysis and a number of simulated and empirical datasets. We compared this covariance model with other existing covariance models such as conventional diagonal covariance, one-pair and multi-pair noise covariance models, when noise information is sufficient to estimate them. We

  9. An analysis of seismic background noise variation and evaluation of detection capability of Keskin Array (BRTR PS-43) in Turkey

    Science.gov (United States)

    Bakir, M. E.; Ozel, N. M.; Semin, K. U.

    2011-12-01

    Bogazici University, Kandilli Observatory and Earthquake Research Institute (KOERI) is currently operating the Keskin seismic array (BRTR-PS 43) located in town Keskin, providing real-time data to IDC. The instrumentaion of seismic array includes six short period borehole seismometers and one broadband borehole seismometer. The seismic background noise variation of Keskin array are studied in order to estimate the local and regional event detection capability in the frequency range from 1 Hz to 10 Hz. The Power density spectrum and also probability density function of Keskin array data were computed for seasonal and diurnal noise variations between 2008 and 2010. The computation will be extended to cover the period between 2005 and 2008. We attempt to determine the precise frequency characteristics of the background noise, which will help us to assess the station sensitivity. Minimum detectable magnitude versus distance for Keskin seismic array will be analyzed based on the seismic noise analysis. Detailed analysis results of seismic background noise and detection capability will be presented by this research.

  10. Description of Anomalous Noise Events for Reliable Dynamic Traffic Noise Mapping in Real-Life Urban and Suburban Soundscapes

    Directory of Open Access Journals (Sweden)

    Francesc Alías

    2017-02-01

    Full Text Available Traffic noise is one of the main pollutants in urban and suburban areas. European authorities have driven several initiatives to study, prevent and reduce the effects of exposure of population to traffic. Recent technological advances have allowed the dynamic computation of noise levels by means of Wireless Acoustic Sensor Networks (WASN such as that developed within the European LIFE DYNAMAP project. Those WASN should be capable of detecting and discarding non-desired sound sources from road traffic noise, denoted as anomalous noise events (ANE, in order to generate reliable noise level maps. Due to the local, occasional and diverse nature of ANE, some works have opted to artificially build ANE databases at the cost of misrepresentation. This work presents the production and analysis of a real-life environmental audio database in two urban and suburban areas specifically conceived for anomalous noise events’ collection. A total of 9 h 8 min of labelled audio data is obtained differentiating among road traffic noise, background city noise and ANE. After delimiting their boundaries manually, the acoustic salience of the ANE samples is automatically computed as a contextual signal-to-noise ratio (SNR. The analysis of the real-life environmental database shows high diversity of ANEs in terms of occurrences, durations and SNRs, as well as confirming both the expected differences between the urban and suburban soundscapes in terms of occurrences and SNRs, and the rare nature of ANE.

  11. Nuclear reactor pump diagnostics via noise analysis/artificial neural networks

    International Nuclear Information System (INIS)

    Keyvan, S.; Rabelo, L.C.

    1991-01-01

    A feasibility study is performed on the utilization of artificial neural networks as a tool for reactor diagnostics. Reactor pump signals utilized in a wear-out monitoring system developed for early detection of degradation of pump shaft are analyzed as a semi-benchmark test to study the feasibility of neural networks for pattern recognition. The Adaptive Resonance Theory (ART 2) paradigm of artificial neural networks is applied in this study. The signals are collected signals as well as generated signals simulating the wear progress. The wear-out monitoring system applies noise analysis techniques, and is capable of distinguishing between these signals and providing a measure of the progress of the degradation. This paper presents the results of the analysis of these data via the ART 2 paradigm

  12. Significant improvement of electrochemical performance of Cu ...

    Indian Academy of Sciences (India)

    LiVPO4F cathode material for lithium-ion batteries. YU ZHANGa,∗, XIAOLAN BAIb ... and energy dispersive spectroscopy (EDS). ... Analysis of electrochemical impedance spectra (EIS) ... studied with a SEM (JSM-7500F, Japan) equipped with.

  13. Applications of Nonlinear Electrochemical Impedance Spectroscopy (NLEIS)

    KAUST Repository

    Adler, S. B.

    2013-01-01

    This paper reviews the use of nonlinear electrochemical impedance spectroscopy (NLEIS) in the analysis of SOFC electrode reactions. By combining EIS and NLEIS, as well as other independent information about an electrode material, it becomes possible

  14. On the Impact of Anomalous Noise Events on Road Traffic Noise Mapping in Urban and Suburban Environments.

    Science.gov (United States)

    Orga, Ferran; Alías, Francesc; Alsina-Pagès, Rosa Ma

    2017-12-23

    Noise pollution is a critical factor affecting public health, the relationship between road traffic noise (RTN) and several diseases in urban areas being especially disturbing. The Environmental Noise Directive 2002/49/EC and the CNOSSOS-EU framework are the main instruments of the European Union to identify and combat noise pollution, requiring Member States to compose and publish noise maps and noise management action plans every five years. Nowadays, the noise maps are starting to be tailored by means of Wireless Acoustic Sensor Networks (WASN). In order to exclusively monitor the impact of RTN on the well-being of citizens through WASN-based approaches, those noise sources unrelated to RTN denoted as Anomalous Noise Events (ANEs) should be removed from the noise map generation. This paper introduces an analysis methodology considering both Signal-to-Noise Ratio (SNR) and duration of ANEs to evaluate their impact on the A-weighted equivalent RTN level calculation for different integration times. The experiments conducted on 9 h of real-life data from the WASN-based DYNAMAP project show that both individual high-impact events and aggregated medium-impact events bias significantly the equivalent noise levels of the RTN map, making any derived study about public health impact inaccurate.

  15. High frequency microseismic noise as possible earthquake precursor

    OpenAIRE

    Ivica Sović; Kristina Šariri; Mladen Živčić

    2013-01-01

    Before an earthquake occurs, microseismic noise in high frequency (HF) range, i.e. 2-25 Hz, is being generated during preparation process. These signals change the microseismic noise and, consequently, the spectrum of microseismic noise. Time variation of spectra recorded at the same seismological station could imply the change of the state of noise source. We propose the image moment analysis approach to objectively compare microseismic noise spectra. The result could be used for earthquake ...

  16. Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soyoung [Department of Radiation Oncology, University Hospitals Case and Medical Center, Cleveland, Ohio 44106 (United States); Yan, Guanghua; Bassett, Philip; Samant, Sanjiv, E-mail: samant@ufl.edu [Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida 32608 (United States); Gopal, Arun [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States)

    2016-09-15

    Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two

  17. Electrochemical Corrosion of Stainless Steel in Thiosulfate Solutions Relevant to Gold Leaching

    Science.gov (United States)

    Choudhary, Lokesh; Wang, Wei; Alfantazi, Akram

    2016-01-01

    This study aims to characterize the electrochemical corrosion behavior of stainless steel in the ammoniacal thiosulfate gold leaching solutions. Electrochemical corrosion response was investigated using potentiodynamic polarization and electrochemical impedance spectroscopy, while the semi-conductive properties and the chemical composition of the surface film were characterized using Mott-Schottky analysis and X-ray photoelectron spectroscopy, respectively. The morphology of the corroded specimens was analyzed using scanning electron microscopy. The stainless steel 316L showed no signs of pitting in the ammoniacal thiosulfate solutions.

  18. Electrochemical deposition of coatings of highly entropic alloys from non-aqueous solutions

    Directory of Open Access Journals (Sweden)

    Jeníček V.

    2016-03-01

    Full Text Available The paper deals with electrochemical deposition of coatings of highly entropic alloys. These relatively new materials have been recently intensively studied. The paper describes the first results of electrochemical coating with highly entropic alloys by deposition from non-aqueous solutions. An electrochemical device was designed and coatings were deposited. The coatings were characterised with electronic microscopy scanning, atomic absorption spectrometry and X-ray diffraction methods and the combination of methods of thermic analysis of differential scanning calorimetry and thermogravimetry.

  19. Quality control in digital mammography: the noise components

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando [Universidade de Tarapaca, Arica (Chile). Centro de Estudios en Ciencias Radiologicas; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Duran, Maria Paz [Clinica Alemana, Santiago (Chile). Dept. de Radiologia; Dantas, Marcelino, E-mail: marcelino@inb.gov.b [Industrias Nucleares do Brasil (INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Ubeda, Carlos, E-mail: cubeda@uta.c [Universidade de Tarapaca, Arica (Chile). Fac. de Ciencias de la Salud

    2011-07-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  20. Quality control in digital mammography: the noise components

    International Nuclear Information System (INIS)

    Leyton, Fernando; Nogueira, Maria do Socorro; Duran, Maria Paz; Dantas, Marcelino; Ubeda, Carlos

    2011-01-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  1. Experimental bifurcation analysis—Continuation for noise-contaminated zero problems

    DEFF Research Database (Denmark)

    Schilder, Frank; Bureau, Emil; Santos, Ilmar Ferreira

    2015-01-01

    Noise contaminated zero problems involve functions that cannot be evaluated directly, but only indirectly via observations. In addition, such observations are affected by a non-deterministic observation error (noise). We investigate the application of numerical bifurcation analysis for studying...... the solution set of such noise contaminated zero problems, which is highly relevant in the context of equation-free analysis (coarse grained analysis) and bifurcation analysis in experiments, and develop specialized algorithms to address challenges that arise due to the presence of noise. As a working example......, we demonstrate and test our algorithms on a mechanical nonlinear oscillator experiment using control based continuation, which we used as a main application and test case for development of the Coco compatible Matlab toolbox Continex that implements our algorithms....

  2. A genome-wide analysis of promoter-mediated phenotypic noise in Escherichia coli.

    Directory of Open Access Journals (Sweden)

    Olin K Silander

    2012-01-01

    Full Text Available Gene expression is subject to random perturbations that lead to fluctuations in the rate of protein production. As a consequence, for any given protein, genetically identical organisms living in a constant environment will contain different amounts of that particular protein, resulting in different phenotypes. This phenomenon is known as "phenotypic noise." In bacterial systems, previous studies have shown that, for specific genes, both transcriptional and translational processes affect phenotypic noise. Here, we focus on how the promoter regions of genes affect noise and ask whether levels of promoter-mediated noise are correlated with genes' functional attributes, using data for over 60% of all promoters in Escherichia coli. We find that essential genes and genes with a high degree of evolutionary conservation have promoters that confer low levels of noise. We also find that the level of noise cannot be attributed to the evolutionary time that different genes have spent in the genome of E. coli. In contrast to previous results in eukaryotes, we find no association between promoter-mediated noise and gene expression plasticity. These results are consistent with the hypothesis that, in bacteria, natural selection can act to reduce gene expression noise and that some of this noise is controlled through the sequence of the promoter region alone.

  3. Power reactor noise measurements in Hungary

    International Nuclear Information System (INIS)

    Pallagi, D.; Horanyi, S.; Hargitai, T.

    1975-01-01

    An outline is given of the history of reactor noise research in Hungary. A brief description is given of studies in the WWR-SM reactor, a modified version of the original WWR-S thermal reactor, for the detection of in-core simulated boiling by analysis of the noise of out-of-core ionization chambers. Coolant velocity measurements by transit time analysis of temperature fluctuations are described. (U.K.)

  4. Practical Ranges of Loudness Levels of Various Types of Environmental Noise, Including Traffic Noise, Aircraft Noise, and Industrial Noise

    Directory of Open Access Journals (Sweden)

    Sabine A. Janssen

    2011-05-01

    Full Text Available In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A‑weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.

  5. Development of a lab-on-chip electrochemical biosensor for water quality analysis based on microalgal photosynthesis.

    Science.gov (United States)

    Tsopela, A; Laborde, A; Salvagnac, L; Ventalon, V; Bedel-Pereira, E; Séguy, I; Temple-Boyer, P; Juneau, P; Izquierdo, R; Launay, J

    2016-05-15

    The present work was dedicated to the development of a lab-on-chip device for water toxicity analysis and more particularly herbicide detection in water. It consists in a portable system for on-site detection composed of three-electrode electrochemical microcells, integrated on a fluidic platform constructed on a glass substrate. The final goal is to yield a system that gives the possibility of conducting double, complementary detection: electrochemical and optical and therefore all materials used for the fabrication of the lab-on-chip platform were selected in order to obtain a device compatible with optical technology. The basic detection principle consisted in electrochemically monitoring disturbances in metabolic photosynthetic activities of algae induced by the presence of Diuron herbicide. Algal response, evaluated through oxygen (O2) monitoring through photosynthesis was different for each herbicide concentration in the examined sample. A concentration-dependent inhibition effect of the herbicide on photosynthesis was demonstrated. Herbicide detection was achieved through a range (blank - 1 µM Diuron herbicide solution) covering the limit of maximum acceptable concentration imposed by Canadian government (0.64 µM), using a halogen white light source for the stimulation of algal photosynthetic apparatus. Superior sensitivity results (limit of detection of around 0.1 µM) were obtained with an organic light emitting diode (OLED), having an emission spectrum adapted to algal absorption spectrum and assembled on the final system. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The Analysis and Suppression of the spike noise in vibrator record

    Science.gov (United States)

    Jia, H.; Jiang, T.; Xu, X.; Ge, L.; Lin, J.; Yang, Z.

    2013-12-01

    During the seismic exploration with vibrator, seismic recording systems have often been affected by random spike noise in the background, which leads to strong data distortions as a result of the cross-correlation processing of the vibrator method. Partial or total loss of the desired seismic information is possible if no automatic spike reduction is available in the field prior to correlation of the field record. Generally speaking, original record of vibrator is uncorrelated data, in which the signal is non-wavelet form. In order to obtain the seismic record similar to explosive source, the signal of uncorrelated data needs to use the correlation algorithm to compress into wavelet form. The correlation process results in that the interference of spike in correlated data is not only being suppressed, but also being expanded. So the spike noise suppression of vibrator is indispensable. According to numerical simulation results, the effect of spike in the vibrator record is mainly affected by the amplitude and proportional points in the uncorrelated record. When the spike noise ratio in uncorrelated record reaches 1.5% and the average amplitude exceeds 200, it will make the SNR(signal-to-noise ratio) of the correlated record lower than 0dB, so that it is difficult to separate the signal. While the amplitude and ratio is determined by the intensity of background noise. Therefore, when the noise level is strong, in order to improve SNR of the seismic data, the uncorrelated record of vibrator need to take necessary steps to suppress spike noise. For the sake of reducing the influence of the spike noise, we need to make the detection and suppression of spike noise process for the uncorrelated record. Because vibrator works by inputting sweep signal into the underground long time, ideally, the peak and valley values of each trace have little change. On the basis of the peak and valley values, we can get a reference amplitude value. Then the spike can be detected and

  7. Magnetic field effects on electrochemical metal depositions

    Directory of Open Access Journals (Sweden)

    Andreas Bund, Adriana Ispas and Gerd Mutschke

    2008-01-01

    Full Text Available This paper discusses recent experimental and numerical results from the authors' labs on the effects of moderate magnetic (B fields in electrochemical reactions. The probably best understood effect of B fields during electrochemical reactions is the magnetohydrodynamic (MHD effect. In the majority of cases it manifests itself in increased mass transport rates which are a direct consequence of Lorentz forces in the bulk of the electrolyte. This enhanced mass transport can directly affect the electrocrystallization. The partial currents for the nucleation of nickel in magnetic fields were determined using an in situ micro-gravimetric technique and are discussed on the basis of the nucleation model of Heerman and Tarallo. Another focus of the paper is the numerical simulation of MHD effects on electrochemical metal depositions. A careful analysis of the governing equations shows that many MHD problems must be treated in a 3D geometry. In most cases there is a complex interplay of natural and magnetically driven convection.

  8. Coherent network analysis technique for discriminating gravitational-wave bursts from instrumental noise

    International Nuclear Information System (INIS)

    Chatterji, Shourov; Lazzarini, Albert; Stein, Leo; Sutton, Patrick J.; Searle, Antony; Tinto, Massimo

    2006-01-01

    The sensitivity of current searches for gravitational-wave bursts is limited by non-Gaussian, nonstationary noise transients which are common in real detectors. Existing techniques for detecting gravitational-wave bursts assume the output of the detector network to be the sum of a stationary Gaussian noise process and a gravitational-wave signal. These techniques often fail in the presence of noise nonstationarities by incorrectly identifying such transients as possible gravitational-wave bursts. Furthermore, consistency tests currently used to try to eliminate these noise transients are not applicable to general networks of detectors with different orientations and noise spectra. In order to address this problem we introduce a fully coherent consistency test that is robust against noise nonstationarities and allows one to distinguish between gravitational-wave bursts and noise transients in general detector networks. This technique does not require any a priori knowledge of the putative burst waveform

  9. An analysis of low frequency noise from large wind turbines

    DEFF Research Database (Denmark)

    Pedersen, Christian Sejer; Møller, Henrik

    2010-01-01

    As wind turbines get larger, worries have emerged, that the noise emitted by the turbines would move down in frequency, and that the contents of low-frequency noise would be enough to cause significant annoyance for the neighbors. The sound emission from 48 wind turbines with nominal electric power......-third-octave-band spectra shows that the relative noise emission is higher in the 63-250 Hz frequency range from turbines above 2 MW than from smaller turbines. The observations confirm a downward shift of the spectrum....

  10. Hydrogen storage material, electrochemically active material, electrochemical cell and electronic equipment

    NARCIS (Netherlands)

    2008-01-01

    The invention relates to a hydrogen storage material comprising an alloy of magnesium. The invention further relates to an electrochemically active material and an electrochemical cell provided with at least one electrode comprising such a hydrogen storage material. Also, the invention relates to

  11. Analysis and suppression of passive noise in surface microseismic data

    Science.gov (United States)

    Forghani-Arani, Farnoush

    Surface microseismic surveys are gaining popularity in monitoring the hydraulic fracturing process. The effectiveness of these surveys, however, is strongly dependent on the signal-to-noise ratio of the acquired data. Cultural and industrial noise generated during hydraulic fracturing operations usually dominate the data, thereby decreasing the effectiveness of using these data in identifying and locating microseismic events. Hence, noise suppression is a critical step in surface microseismic monitoring. In this thesis, I focus on two important aspects in using surface-recorded microseismic seismic data: first, I take advantage of the unwanted surface noise to understand the characteristics of these noise and extract information about the propagation medium from the noise; second, I propose effective techniques to suppress the surface noise while preserving the waveforms that contain information about the source of microseisms. Automated event identification on passive seismic data using only a few receivers is challenging especially when the record lengths span over long durations of time. I introduce an automatic event identification algorithm that is designed specifically for detecting events in passive data acquired with a small number of receivers. I demonstrate that the conventional STA/LTA (Short-term Average/Long-term Average) algorithm is not sufficiently effective in event detection in the common case of low signal-to-noise ratio. With a cross-correlation based method as an extension of the STA/LTA algorithm, even low signal-to-noise events (that were not detectable with conventional STA/LTA) were revealed. Surface microseismic data contains surface-waves (generated primarily from hydraulic fracturing activities) and body-waves in the form of microseismic events. It is challenging to analyze the surface-waves on the recorded data directly because of the randomness of their source and their unknown source signatures. I use seismic interferometry to extract

  12. Signal discrimination of ULF electromagnetic data with using singular spectrum analysis – an attempt to detect train noise

    Directory of Open Access Journals (Sweden)

    S. Saito

    2011-07-01

    Full Text Available Electromagnetic phenomena associated with crustal activities have been reported in a wide frequency range (DC-HF. In particular, ULF electromagnetic phenomena are the most promising among them because of the deeper skin depth. However, ULF geoelctromagnetic data are a superposition of signals of different origins. They originated from interactions between the geomagnetic field and the solar wind, leak current by a DC-driven train (train noise, precipitation, and so on. In general, the intensity of electromagnetic signals associated with crustal activity is smaller than the above variations. Therefore, in order to detect a smaller signal, signal discrimination such as noise reduction or identification of noises is very important. In this paper, the singular spectrum analysis (SSA has been performed to detect the DC-driven train noise in geoelectric potential difference data. The aim of this paper is to develop an effective algorithm for the DC-driven train noise detection.

  13. Mathematical modeling and hydrodynamics of Electrochemical deburring process

    Science.gov (United States)

    Prabhu, Satisha; Abhishek Kumar, K., Dr

    2018-04-01

    The electrochemical deburring (ECD) is a variation of electrochemical machining is considered as one of the efficient methods for deburring of intersecting features and internal parts. Since manual deburring costs are comparatively high one can potentially use this method in both batch production and flow production. The other advantage of this process is that time of deburring as is on the order of seconds as compared to other methods. In this paper, the mathematical modeling of Electrochemical deburring is analysed from its deburring time and base metal removal point of view. Simultaneously material removal rate is affected by electrolyte temperature and bubble formation. The mathematical model and hydrodynamics of the process throw limelight upon optimum velocity calculations which can be theoretically determined. The analysis can be the powerful tool for prediction of the above-mentioned parameters by experimentation.

  14. Graphene-Paper Based Electrochemical Sensors

    DEFF Research Database (Denmark)

    Zhang, Minwei; Halder, Arnab; Cao, Xianyi

    2017-01-01

    in electrochemical sensors and energy technologies amongothers. In this chapter, we present some examples to overview recent advances in theresearch and development of two-dimensional (2D) graphene papers as new materialsfor electrochemical sensors. The chapter covers the design, fabrication, functionalizationand...... functionalization ofgraphene papers with polymer and nanoscale functional building blocks for electrochemical-sensing purposes. In terms of electrochemical-sensing applications, the emphasis ison enzyme-graphene and nanoparticle-graphene paper-based systems for the detectionof glucose. We finally conclude...

  15. Analysis of annual exposure of private farmers to noise and whole body vibration

    Directory of Open Access Journals (Sweden)

    Leszek Solecki

    2012-06-01

    Full Text Available Based on a literature review for the period of 1982– 2011, an analysis was performed of studies by various researchers concerning the exposure of private farmers to noise and vibration of the whole body with particular consideration of the annual exposure to these factors. The main sources of noise occurring in agriculture are: agricultural tractors mounted with a set of farm machinery, self-propelled machines, machinery for the production of fodder and workshop equipment. The review of literature showed that the highest values of equivalent exposure to noise (EA, T or noise doses (d were noted during the summer-autumn season and in spring. Mean noise levels for the entire year (of over 90 dB-A, considerably exceeded permissible values.The primary sources of the whole body vibration are agricultural vehicles including agricultural tractors of various types and self-propelled agricultural vehicles. In these vehicles vibration transmitted from the seat to the whole body is of basic importance. The measurements of vibration acceleration indicated that mechanical vibration on seats was produced while performing following activities: hay tedding and raking, sowing of fertilizers, aggregation of soil, grass mowing and cultivation. All of them may create a considerable health risk. These work activities are performed at elevated working speeds of tractors, most often along with hardened or uneven surfaces. In relation to the standard values (A(840.8 m/s2, the mean daily vibration acceleration values remain below the permissible levels during all months of the year. However, considering the occurrence of mechanical shocks of high values (above the Maximum Acceptable Intensity on agricultural vehicles there is a high risk for the spine problems among operators of agricultural vehicles.

  16. analysis of the environmental and socio-economic impact of noise

    African Journals Online (AJOL)

    Dr Obe

    Interest in noise control studies is only recent in Nigeria. ... standards for environmental pollution by the Federal ... heaters, gas flare system, reactors, water injection plants, pumps ..... review of health effects of aircraft noise. Aust. NZ J. Public ...

  17. 3,5-Diamino-1,2,4-triazole@electrochemically reduced graphene oxide film modified electrode for the electrochemical determination of 4-nitrophenol

    International Nuclear Information System (INIS)

    Kumar, Deivasigamani Ranjith; Kesavan, Srinivasan; Baynosa, Marjorie Lara; Shim, Jae-Jin

    2017-01-01

    Highlights: •Triazole film was formed on electrochemically reduced graphene oxide. •pDAT@ERGO/GC was utilized for the electrochemical determination of 4-nitrophenol. •pDAT@ERGO/GC electrode offered wide concentration and nanomolar detection limit. •The fabricated electrode was employed in water sample analyses. -- Abstract: In this study, an eco-friendly benign method for the modification of electrochemically reduced graphene oxide (ERGO) on glassy carbon (GC) surface and electrochemical polymerized 3,5-diamino-1,2,4-triazole (DAT) film composite (pDAT@ERGO/GC) electrode was developed. The surface morphologies of the pDAT@ERGO/GC modified electrode were analyzed by field emission scanning electron microscopy (FESEM). FESEM images indicated that the ERGO supported pDAT has an almost homogeneous morphology structure with a size of 70 to 80 nm. It is due to the water oxidation reaction occurred while pDAT@ERGO/GC fabrication peak at +1.4 V leads to O 2 evolution and oxygen functional group functionalization on ERGO, which confirmed by X-ray photoelectron spectroscopy (XPS). In contrast, the bare GC modified with pDAT showed randomly arranged irregular bulky morphology structure compared to those of pDAT@ERGO/GC. Electrochemical reduction of graphene oxide was confirmed by Raman spectroscopy, XPS, and electrochemical impedance spectroscopy (EIS). The pDAT@ERGO/GC modified electrode was used for the electrochemical determination of 4-nitrophenol (4-NP). The 4-NP oxidation peak was observed at +0.25 V, and the differential pulse voltammetry demonstrated wide concentration range (5–1500 μM), high sensitivity (0.7113 μA μM −1 ), and low limit of detection (37 nM). Moreover, the pDAT@ERGO/GC electrode was applied to real water sample analysis by standard addition method, where in good recoveries (97.8% to 102.4%) were obtained.

  18. Noise correlations in cosmic microwave background experiments

    Science.gov (United States)

    Dodelson, Scott; Kosowsky, Arthur; Myers, Steven T.

    1995-01-01

    Many analysis of microwave background experiments neglect the correlation of noise in different frequency of polarization channels. We show that these correlations, should they be present, can lead to serve misinterpretation of an experiment. In particular, correlated noise arising from either electronics or atmosphere may mimic a cosmic signal. We quantify how the likelihood function for a given experiment varies with noise correlation, using both simple analytic models and actual data. For a typical microwave background anisotropy experiment, noise correlations at the level of 1% of the overall noise can seriously reduce the significance of a given detection.

  19. Automatic physiological waveform processing for FMRI noise correction and analysis.

    Directory of Open Access Journals (Sweden)

    Daniel J Kelley

    2008-03-01

    Full Text Available Functional MRI resting state and connectivity studies of brain focus on neural fluctuations at low frequencies which share power with physiological fluctuations originating from lung and heart. Due to the lack of automated software to process physiological signals collected at high magnetic fields, a gap exists in the processing pathway between the acquisition of physiological data and its use in fMRI software for both physiological noise correction and functional analyses of brain activation and connectivity. To fill this gap, we developed an open source, physiological signal processing program, called PhysioNoise, in the python language. We tested its automated processing algorithms and dynamic signal visualization on resting monkey cardiac and respiratory waveforms. PhysioNoise consistently identifies physiological fluctuations for fMRI noise correction and also generates covariates for subsequent analyses of brain activation and connectivity.

  20. Analysis of a sub-shot-noise power recycled Michelson interferometer

    International Nuclear Information System (INIS)

    McKenzie, K; Buchler, B C; Shaddock, D A; Lam, P K; McClelland, D E

    2004-01-01

    The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods

  1. Response analysis of a class of quasi-linear systems with fractional derivative excited by Poisson white noise

    Science.gov (United States)

    Yang, Yongge; Xu, Wei; Yang, Guidong; Jia, Wantao

    2016-08-01

    The Poisson white noise, as a typical non-Gaussian excitation, has attracted much attention recently. However, little work was referred to the study of stochastic systems with fractional derivative under Poisson white noise excitation. This paper investigates the stationary response of a class of quasi-linear systems with fractional derivative excited by Poisson white noise. The equivalent stochastic system of the original stochastic system is obtained. Then, approximate stationary solutions are obtained with the help of the perturbation method. Finally, two typical examples are discussed in detail to demonstrate the effectiveness of the proposed method. The analysis also shows that the fractional order and the fractional coefficient significantly affect the responses of the stochastic systems with fractional derivative.

  2. Response analysis of a class of quasi-linear systems with fractional derivative excited by Poisson white noise

    International Nuclear Information System (INIS)

    Yang, Yongge; Xu, Wei; Yang, Guidong; Jia, Wantao

    2016-01-01

    The Poisson white noise, as a typical non-Gaussian excitation, has attracted much attention recently. However, little work was referred to the study of stochastic systems with fractional derivative under Poisson white noise excitation. This paper investigates the stationary response of a class of quasi-linear systems with fractional derivative excited by Poisson white noise. The equivalent stochastic system of the original stochastic system is obtained. Then, approximate stationary solutions are obtained with the help of the perturbation method. Finally, two typical examples are discussed in detail to demonstrate the effectiveness of the proposed method. The analysis also shows that the fractional order and the fractional coefficient significantly affect the responses of the stochastic systems with fractional derivative.

  3. Response analysis of a class of quasi-linear systems with fractional derivative excited by Poisson white noise

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yongge; Xu, Wei, E-mail: weixu@nwpu.edu.cn; Yang, Guidong; Jia, Wantao [Department of Applied Mathematics, Northwestern Polytechnical University, Xi' an 710072 (China)

    2016-08-15

    The Poisson white noise, as a typical non-Gaussian excitation, has attracted much attention recently. However, little work was referred to the study of stochastic systems with fractional derivative under Poisson white noise excitation. This paper investigates the stationary response of a class of quasi-linear systems with fractional derivative excited by Poisson white noise. The equivalent stochastic system of the original stochastic system is obtained. Then, approximate stationary solutions are obtained with the help of the perturbation method. Finally, two typical examples are discussed in detail to demonstrate the effectiveness of the proposed method. The analysis also shows that the fractional order and the fractional coefficient significantly affect the responses of the stochastic systems with fractional derivative.

  4. Nanostructured Electrode Materials for Electrochemical Capacitor Applications.

    Science.gov (United States)

    Choi, Hojin; Yoon, Hyeonseok

    2015-06-02

    The advent of novel organic and inorganic nanomaterials in recent years, particularly nanostructured carbons, conducting polymers, and metal oxides, has enabled the fabrication of various energy devices with enhanced performance. In this paper, we review in detail different nanomaterials used in the fabrication of electrochemical capacitor electrodes and also give a brief overview of electric double-layer capacitors, pseudocapacitors, and hybrid capacitors. From a materials point of view, the latest trends in electrochemical capacitor research are also discussed through extensive analysis of the literature and by highlighting notable research examples (published mostly since 2013). Finally, a perspective on next-generation capacitor technology is also given, including the challenges that lie ahead.

  5. Road traffic noise: self-reported noise annoyance versus GIS modelled road traffic noise exposure.

    Science.gov (United States)

    Birk, Matthias; Ivina, Olga; von Klot, Stephanie; Babisch, Wolfgang; Heinrich, Joachim

    2011-11-01

    self-reported road traffic noise annoyance is commonly used in epidemiological studies for assessment of potential health effects. Alternatively, some studies have used geographic information system (GIS) modelled exposure to road traffic noise as an objective parameter. The aim of this study was to analyse the association between noise exposure due to neighbouring road traffic and the noise annoyance of adults, taking other determinants into consideration. parents of 951 Munich children from the two German birth cohorts GINIplus and LISAplus reported their annoyance due to road traffic noise at home. GIS modelled road traffic noise exposure (L(den), maximum within a 50 m buffer) from the noise map of the city of Munich was available for all families. GIS-based calculated distance to the closest major road (≥10,000 vehicles per day) and questionnaire based-information about family income, parental education and the type of the street of residence were explored for their potential influence. An ordered logit regression model was applied. The noise levels (L(den)) and the reported noise annoyance were compared with an established exposure-response function. the correlation between noise annoyance and noise exposure (L(den)) was fair (Spearman correlation r(s) = 0.37). The distance to a major road and the type of street were strong predictors for the noise annoyance. The annoyance modelled by the established exposure-response function and that estimated by the ordered logit model were moderately associated (Pearson's correlation r(p) = 0.50). road traffic noise annoyance was associated with GIS modelled neighbouring road traffic noise exposure (L(den)). The distance to a major road and the type of street were additional explanatory factors of the noise annoyance appraisal.

  6. Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang Kai; Huang, Shih-Ying; Packard, Nathan J.; Boone, John M. [Department of Radiology, University of California, Davis Medical Center, 4860 Y Street, Suite 3100 Ellison Building, Sacramento, California 95817 (United States); Department of Radiology, University of California, Davis Medical Center, 4860 Y Street, Suite 3100 Ellison Building, Sacramento, California 95817 (United States) and Department of Biomedical Engineering, University of California, Davis, Davis, California, 95616 (United States)

    2010-07-15

    Purpose: A simplified linear model approach was proposed to accurately model the response of a flat panel detector used for breast CT (bCT). Methods: Individual detector pixel mean and variance were measured from bCT projection images acquired both in air and with a polyethylene cylinder, with the detector operating in both fixed low gain and dynamic gain mode. Once the coefficients of the linear model are determined, the fractional additive noise can be used as a quantitative metric to evaluate the system's efficiency in utilizing x-ray photons, including the performance of different gain modes of the detector. Results: Fractional additive noise increases as the object thickness increases or as the radiation dose to the detector decreases. For bCT scan techniques on the UC Davis prototype scanner (80 kVp, 500 views total, 30 frames/s), in the low gain mode, additive noise contributes 21% of the total pixel noise variance for a 10 cm object and 44% for a 17 cm object. With the dynamic gain mode, additive noise only represents approximately 2.6% of the total pixel noise variance for a 10 cm object and 7.3% for a 17 cm object. Conclusions: The existence of the signal-independent additive noise is the primary cause for a quadratic relationship between bCT noise variance and the inverse of radiation dose at the detector. With the knowledge of the additive noise contribution to experimentally acquired images, system modifications can be made to reduce the impact of additive noise and improve the quantum noise efficiency of the bCT system.

  7. Electrochemical oxidation of selective estrogen receptor modulator raloxifene

    International Nuclear Information System (INIS)

    Li, Xi-Qian; He, Jian-Bo; Liu, Lu; Cui, Ting

    2013-01-01

    Highlights: ► Application and analysis of in situ thin-layer spectroelectrochemistry. ► Cyclic voltabsorptometry used for a drug study. ► Highly pH-dependent oxidative metabolism of raloxifene. ► A complex parallel-consecutive mechanism proposed for oxidation of raloxifene. -- Abstract: Raloxifene is a selective estrogen receptor modulator that may produce toxic oxidative species in metabolism. The oxidation mechanism of raloxifene with different pH values was studied by cyclic voltammetry, X-ray photoelectron spectroscopy (XPS), in situ UV–vis spectral analysis and cyclic voltabsorptometry based on a long optical-path thin-layer electrochemical cell. Time-derivative cyclic voltabsorptograms were obtained for comparative discussion with the corresponding cyclic voltammograms. Raloxifene was initially oxidized to reactive phenoxyl radicals, followed by a series of transformation steps leading to different final products in different pH media. A parallel-consecutive reaction mechanism was proposed for the pH-dependent formation of 7-hydroxyraloxifene, raloxifene 6,7-o-quinone and two raloxifene dimers, each pathway following a complex electrochemical-chemical mechanism. Both raloxifene diquinone methide and its N-oxides were not detected by in situ UV–vis spectroscopy and XPS analysis. This work provides an electrochemical viewpoint and comparable information for better understanding of the oxidative metabolism and chemical toxicology of raloxifene under physiological conditions in vivo or in vitro

  8. Multivariate statistical pattern recognition system for reactor noise analysis

    International Nuclear Information System (INIS)

    Gonzalez, R.C.; Howington, L.C.; Sides, W.H. Jr.; Kryter, R.C.

    1976-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis was developed. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, and updating capabilities. System design emphasizes control of the false-alarm rate. The ability of the system to learn normal patterns of reactor behavior and to recognize deviations from these patterns was evaluated by experiments at the ORNL High-Flux Isotope Reactor (HFIR). Power perturbations of less than 0.1 percent of the mean value in selected frequency ranges were detected by the system

  9. Multivariate statistical pattern recognition system for reactor noise analysis

    International Nuclear Information System (INIS)

    Gonzalez, R.C.; Howington, L.C.; Sides, W.H. Jr.; Kryter, R.C.

    1975-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis was developed. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, and updating capabilities. System design emphasizes control of the false-alarm rate. The ability of the system to learn normal patterns of reactor behavior and to recognize deviations from these patterns was evaluated by experiments at the ORNL High-Flux Isotope Reactor (HFIR). Power perturbations of less than 0.1 percent of the mean value in selected frequency ranges were detected by the system. 19 references

  10. A simple white noise analysis of neuronal light responses.

    Science.gov (United States)

    Chichilnisky, E J

    2001-05-01

    A white noise technique is presented for estimating the response properties of spiking visual system neurons. The technique is simple, robust, efficient and well suited to simultaneous recordings from multiple neurons. It provides a complete and easily interpretable model of light responses even for neurons that display a common form of response nonlinearity that precludes classical linear systems analysis. A theoretical justification of the technique is presented that relies only on elementary linear algebra and statistics. Implementation is described with examples. The technique and the underlying model of neural responses are validated using recordings from retinal ganglion cells, and in principle are applicable to other neurons. Advantages and disadvantages of the technique relative to classical approaches are discussed.

  11. Judgments of aircraft noise in a traffic noise background

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1975-01-01

    An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.

  12. Electrochemical force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Sergei V.; Jesse, Stephen; Collins, Liam F.; Rodriguez, Brian J.

    2017-01-10

    A system and method for electrochemical force microscopy are provided. The system and method are based on a multidimensional detection scheme that is sensitive to forces experienced by a biased electrode in a solution. The multidimensional approach allows separation of fast processes, such as double layer charging, and charge relaxation, and slow processes, such as diffusion and faradaic reactions, as well as capturing the bias dependence of the response. The time-resolved and bias measurements can also allow probing both linear (small bias range) and non-linear (large bias range) electrochemical regimes and potentially the de-convolution of charge dynamics and diffusion processes from steric effects and electrochemical reactivity.

  13. Integrated Electrochemical Analysis System with Microfluidic and Sensing Functions

    Directory of Open Access Journals (Sweden)

    Hiroaki Suzuki

    2008-02-01

    Full Text Available An integrated device that carries out the timely transport of solutions andconducts electroanalysis was constructed. The transport of solutions was based oncapillary action in overall hydrophilic flow channels and control by valves that operateon the basis of electrowetting. Electrochemical sensors including glucose, lactate,glutamic oxaloacetic transaminase (GOT, glutamic pyruvic transaminase (GPT, pH,ammonia, urea, and creatinine were integrated. An air gap structure was used for theammonia, urea, and creatinine sensors to realize a rapid response. To enhance thetransport of ammonia that existed or was produced by the enzymatic reactions, the pHof the solution was elevated by mixing it with a NaOH solution using a valve based onelectrowetting. The sensors for GOT and GPT used a freeze-dried substrate matrix torealize rapid mixing. The sample solution was transported to required sensing sites atdesired times. The integrated sensors showed distinct responses when a sample solutionreached the respective sensing sites. Linear relationships were observed between theoutput signals and the concentration or the logarithm of the concentration of theanalytes. An interferent, L-ascorbic acid, could be eliminated electrochemically in thesample injection port.

  14. On the Electrochemical Behavior of PVD Ti-Coated AISI 304 Stainless Steel in Borate Buffer Solution

    Science.gov (United States)

    Fattah-alhosseini, Arash; Elmkhah, Hassan; Attarzadeh, Farid Reza

    2017-04-01

    This work aims at studying the electrochemical behavior of annealed pure titanium (Ti) and nano-structured (NS) Ti coating in borate buffer solutions. Cathodic arc evaporation was successfully applied to deposit NS Ti coating. Samples were characterized by means of scanning electron microscope and x-ray diffraction. Potentiodynamic polarization tests, electrochemical impedance spectroscopy, and Mott-Schottky analysis were employed to discuss the electrochemical behavior of samples thoroughly. Electrochemical measurements showed that the deposited NS Ti coating offers a superior passivity in borate buffer solutions of pH 9.0 and 9.5. Mott-Schottky analysis revealed that all passive films are of n-type semiconducting nature in these alkaline solutions and the deposition process did not alter the semiconducting type of passive films formed on samples. Additionally, this analysis showed that the NS Ti coating possessed lower levels of donor densities. Finally, all electrochemical tests showed that passive behavior of the NS Ti samples was superior, mainly due to the formation of thicker and less defective passive films.

  15. Noise diagnostic: An advanced technique in Cuba

    International Nuclear Information System (INIS)

    Aguilar, O.

    1992-01-01

    This paper examines the main steps of the noise analysis technique implementation in our country from 1988. The review identifies two main areas, improvements of Nuclear Power Plant operational surveillance techniques and non-nuclear industrial applications. Also reported are some of the on going researches programs including projects on noise analysis instrumentation developments at the Higher Institute for Nuclear Sciences and Technology

  16. Electrochemical Properties of High Surface Area Vanadium Oxide Aerogels

    National Research Council Canada - National Science Library

    Dong, Winny

    2001-01-01

    .... Traditional composite electrode structures have prevented truly quantitative analysis of surface area effects in nanoscale battery materials, as well as a study of their innate electrochemical behavior...

  17. Assessment and analysis of noise levels in and around Ib river coalfield, Orissa, India.

    Science.gov (United States)

    Mohapatra, Haraprasad; Goswami, Shreerup

    2012-05-01

    Heavy earth moving machineries, different capacities of dumpers and loaders, blasting and drilling make the mining environment noisy. A study was carried out to assess the noise level in different opencast projects in and around Belpahar and Brajarajnagar areas of Ib river coalfield. Noise assessment was carried out in various residential, commercial and industrial places. The noise levels, especially L(eq) values of different wheel loaders, dumpers, shovel and crusher units were also assessed and were more than permissible limit (90dB) in some of their operating conditions. Sound ressure level measurements while drilling into coal and overburden at Lakhanpur opencast project yielded noise levels (L(eq)) of 81.33 to 96.2 dB. Thus, these L(eq) values of drilling machines in most of the operating conditions were above permissible limit. The average noise intensities (6 a.m.-10 p.m.: 51.6-60.875dB and 10 p.m.-6 a.m.: 42.6-49.8dB) and L(eq) values (6 a.m.-10 p.m.: 50.9-67.0dB and 10 p.m.-6 a.m.: 40.8-53.3dB) during both day and night time of the residential areas around the Ib river coalfield were in close proximity or beyond the permissible limit. The L(eq) values at some of the commercial and industrial places were beyond (6 a.m.-10 p.m.: 61.6-88.3 dB and 10 p.m.-6 a.m.: 55.4-64.8dB) permissible limit. However, in most of the cases, the L(max) noise values were more (6 a.m.-10 p.m.: 68.5-91.4 dB and 10 p.m.-6 a.m.: 69.3-76.4dB) than the permissible limit. Analysis of variance was also computed for heavy earth moving machineries in different operating conditions and also for different residential, commercial and industrial places to infer the level of significance. The difference of noise intensity produced by different wheel loaders at Lakhanpur and Lilari opencast projects, drilling machines at Lakhanpur opencast project, 50 tons capacity dumpers at various conditions of Ib river coalfield within the same operating condition was significant at both 5% and 1% levels

  18. Electrochemical Synthesis of Polypyrrole, Reduced Graphene Oxide, and Gold Nanoparticles Composite and Its Application to Hydrogen Peroxide Biosensor

    Directory of Open Access Journals (Sweden)

    Baoyan Wu

    2016-11-01

    Full Text Available Here we report a facile eco-friendly one-step electrochemical approach for the fabrication of a polypyrrole (PPy, reduced graphene oxide (RGO, and gold nanoparticles (nanoAu biocomposite on a glassy carbon electrode (GCE. The electrochemical behaviors of PPy–RGO–nanoAu and its application to electrochemical detection of hydrogen peroxide were investigated by cyclic voltammetry. Graphene oxide and pyrrole monomer were first mixed and casted on the surface of a cleaned GCE. After an electrochemical processing consisting of the electrooxidation of pyrrole monomer and simultaneous electroreduction of graphene oxide and auric ions (Au3+ in aqueous solution, a PPy–RGO–nanoAu biocomposite was synthesized on GCE. Each component of PPy–RGO–nanoAu is electroactive without non-electroactive substance. The obtained PPy–RGO–nanoAu/GCE exhibited high electrocatalytic activity toward hydrogen peroxide, which allows the detection of hydrogen peroxide at a negative potential of about −0.62 V vs. SCE. The amperometric responses of the biosensor displayed a sensitivity of 40 µA/mM, a linear range of 32 µM–2 mM, and a detection limit of 2.7 µM (signal-to-noise ratio = 3 with good stability and acceptable reproducibility and selectivity. The results clearly demonstrate the potential of the as-prepared PPy–RGO–nanoAu biocomposite for use as a highly electroactive matrix for an amperometric biosensor.

  19. Application of noise analysis on the operation of the RSG-GAS reactor

    International Nuclear Information System (INIS)

    Surian P, Tukiran S

    1999-01-01

    The RSG-GAS reactor has been operating for radioisotope production and experiments so that it is necessary to perform analysis of the reactor operation. analysis was done based on reactor noise experiment. Neutron noise at low and high power of the RSG-GAS has been analyzed using time and frequency domain with aim to determine the safety of reactor operation. The safety of reactor operation based on two parameters as, prompt neutron decay constant and decay ratio. The parameters are useful for reactor operation, so it is necessary to determine accurately. For determining prompt neutron decay constant, neutron density in the core of reactor which operated at 10 k W, was collected by using Fission Chamber detectors (FC). Based on power spectral density (PSD) was achieved break frequency about 23 Hz, so that the prompt neutron decay constant is about 151 sec -1 . While at at high power 20 MW, neutron density was collected by using Compensated Ionization Chamber (CIC) detector. The result at high power showed that there is reactivity effect in the core because of fluctuation in temperature and density of the coolant, and the decay ratio of 0.20, showed that the reactor is still operation in stable

  20. Materials for electrochemical capacitors

    Science.gov (United States)

    Simon, Patrice; Gogotsi, Yury

    2008-11-01

    Electrochemical capacitors, also called supercapacitors, store energy using either ion adsorption (electrochemical double layer capacitors) or fast surface redox reactions (pseudo-capacitors). They can complement or replace batteries in electrical energy storage and harvesting applications, when high power delivery or uptake is needed. A notable improvement in performance has been achieved through recent advances in understanding charge storage mechanisms and the development of advanced nanostructured materials. The discovery that ion desolvation occurs in pores smaller than the solvated ions has led to higher capacitance for electrochemical double layer capacitors using carbon electrodes with subnanometre pores, and opened the door to designing high-energy density devices using a variety of electrolytes. Combination of pseudo-capacitive nanomaterials, including oxides, nitrides and polymers, with the latest generation of nanostructured lithium electrodes has brought the energy density of electrochemical capacitors closer to that of batteries. The use of carbon nanotubes has further advanced micro-electrochemical capacitors, enabling flexible and adaptable devices to be made. Mathematical modelling and simulation will be the key to success in designing tomorrow's high-energy and high-power devices.

  1. Electrochemical reduction of NOx

    DEFF Research Database (Denmark)

    Traulsen, Marie Lund

    NO and NO2 (collectively referred to as NOx) are air pollutants, and the largest single contributor to NOx pollution is automotive exhaust. This study investigates electrochemical deNOx, a technology which aims to remove NOx from automotive diesel exhaust by electrochemical reduction of NOx to N2...... and O2. The focus in this study is on improving the activity and selectivity of solid oxide electrodes for electrochemical deNOx by addition of NOx storage compounds to the electrodes. Two different composite electrodes, La0.85Sr0.15MnO3-δ-Ce0.9Gd0.1O1.95 (LSM15-CGO10) and La0.85Sr0.15FeO3-δ-Ce0.9Gd0.1O......1.95 (LSF15-CGO10), have been investigated in combination with three different NOx storage compounds: BaO, K2O and MnOx. The main focus in the investigation has been on conversion measurements and electrochemical characterization, the latter by means of electrochemical impedance spectroscopy...

  2. Landing Gear Noise Prediction and Analysis for Tube-and-Wing and Hybrid-Wing-Body Aircraft

    Science.gov (United States)

    Guo, Yueping; Burley, Casey L.; Thomas, Russell H.

    2016-01-01

    Improvements and extensions to landing gear noise prediction methods are developed. New features include installation effects such as reflection from the aircraft, gear truck angle effect, local flow calculation at the landing gear locations, gear size effect, and directivity for various gear designs. These new features have not only significantly improved the accuracy and robustness of the prediction tools, but also have enabled applications to unconventional aircraft designs and installations. Systematic validations of the improved prediction capability are then presented, including parametric validations in functional trends as well as validations in absolute amplitudes, covering a wide variety of landing gear designs, sizes, and testing conditions. The new method is then applied to selected concept aircraft configurations in the portfolio of the NASA Environmentally Responsible Aviation Project envisioned for the timeframe of 2025. The landing gear noise levels are on the order of 2 to 4 dB higher than previously reported predictions due to increased fidelity in accounting for installation effects and gear design details. With the new method, it is now possible to reveal and assess the unique noise characteristics of landing gear systems for each type of aircraft. To address the inevitable uncertainties in predictions of landing gear noise models for future aircraft, an uncertainty analysis is given, using the method of Monte Carlo simulation. The standard deviation of the uncertainty in predicting the absolute level of landing gear noise is quantified and determined to be 1.4 EPNL dB.

  3. Noise estimation of oil lubricated journal bearings

    International Nuclear Information System (INIS)

    Rho, Byoung Hoo; Kim, Kyung Woong

    2003-01-01

    Noise estimating procedures of oil lubricated journal bearings are presented. Nonlinear analysis of rotor-bearing system including unbalance mass of the rotor is performed in order to obtain acoustical properties of the bearing. Acoustical properties of the bearing are investigated through frequency analysis of the pressure fluctuation of the fluid film calculated from the nonlinear analysis. Noise estimating procedures presented in this paper could aid in the evaluation and understanding of acoustical properties of oil lubricated journal bearings

  4. Energy-Based Wavelet De-Noising of Hydrologic Time Series

    Science.gov (United States)

    Sang, Yan-Fang; Liu, Changming; Wang, Zhonggen; Wen, Jun; Shang, Lunyu

    2014-01-01

    De-noising is a substantial issue in hydrologic time series analysis, but it is a difficult task due to the defect of methods. In this paper an energy-based wavelet de-noising method was proposed. It is to remove noise by comparing energy distribution of series with the background energy distribution, which is established from Monte-Carlo test. Differing from wavelet threshold de-noising (WTD) method with the basis of wavelet coefficient thresholding, the proposed method is based on energy distribution of series. It can distinguish noise from deterministic components in series, and uncertainty of de-noising result can be quantitatively estimated using proper confidence interval, but WTD method cannot do this. Analysis of both synthetic and observed series verified the comparable power of the proposed method and WTD, but de-noising process by the former is more easily operable. The results also indicate the influences of three key factors (wavelet choice, decomposition level choice and noise content) on wavelet de-noising. Wavelet should be carefully chosen when using the proposed method. The suitable decomposition level for wavelet de-noising should correspond to series' deterministic sub-signal which has the smallest temporal scale. If too much noise is included in a series, accurate de-noising result cannot be obtained by the proposed method or WTD, but the series would show pure random but not autocorrelation characters, so de-noising is no longer needed. PMID:25360533

  5. Towards a better understanding of helicopter external noise

    Science.gov (United States)

    Damongeot, A.; Dambra, F.; Masure, B.

    The problem of helicopter external noise generation is studied taking into consideration simultaneously the multiple noise sources: rotor rotational-, rotor broadband -, and engine noise. The main data are obtained during flight tests of the rather quiet AS 332 Super Puma. The flight procedures settled by ICAO for noise regulations are used: horizontal flyover at 90 percent of the maximum speed, approach at minimum power velocity, take-off at best rate of climb. Noise source levels are assessed through narrow band analysis of ground microphone recordings, ground measurements of engine noise and theoretical means. With the perceived noise level unit used throughout the study, relative magnitude of noise sources is shown to be different from that obtained with linear noise unit. A parametric study of the influence of some helicopter parameters on external noise has shown that thickness-tapered, chord-tapered, and swept-back blade tips are good means to reduce the overall noise level in flyover and approach.

  6. Verification test for on-line diagnosis algorithm based on noise analysis

    International Nuclear Information System (INIS)

    Tamaoki, T.; Naito, N.; Tsunoda, T.; Sato, M.; Kameda, A.

    1980-01-01

    An on-line diagnosis algorithm was developed and its verification test was performed using a minicomputer. This algorithm identifies the plant state by analyzing various system noise patterns, such as power spectral densities, coherence functions etc., in three procedure steps. Each obtained noise pattern is examined by using the distances from its reference patterns prepared for various plant states. Then, the plant state is identified by synthesizing each result with an evaluation weight. This weight is determined automatically from the reference noise patterns prior to on-line diagnosis. The test was performed with 50 MW (th) Steam Generator noise data recorded under various controller parameter values. The algorithm performance was evaluated based on a newly devised index. The results obtained with one kind of weight showed the algorithm efficiency under the proper selection of noise patterns. Results for another kind of weight showed the robustness of the algorithm to this selection. (orig.)

  7. Assessment, analysis and appraisal of road traffic noise pollution in Rourkela city, India.

    Science.gov (United States)

    Goswami, Shreerup; Swain, Bijay Kumar; Panda, Santosh Kumar

    2013-09-01

    The problem of road traffic noise pollution has become a concern for both the public and the policy makers. Noise level was assessed in 12 different squares of Rourkela city during different specified times (7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m., 7-10 p.m., 10 p.m.-12 midnight and 4-6 a.m.). Noise descriptors such as L,eq, traffic noise index, noise pollution level, noise climate, Lday, Levening, Lnight and Lden were assessed to reveal the extent of noise pollution due to heavy traffic in this city. The equivalent noise levels of all the 12 squares were found to be much beyond the permissible limit (70dB during day time and 55dB during night time). Appallingly, even the minimum L eq and NPL values were more than 82 dB and 96 dB during day time and 69 dB and 91 dB during night time respectively. Lden values of investigated squares ranged from 83.4 to 86.1 dB and were even more than the day time permissible limit of traffic noise. The prediction model was used in the present study to predict noise pollution level instead of Leq. Comparison of predicted with that of the actual measured data demonstrated that the model used for the prediction has the ability to calibrate the multicomponent traffic noise and yield reliable results close to that by direct measurement. Lastly, it is inferred that the dimension of the traffic generated noise pollution in Rourkela is critical.

  8. White noise calculus and Fock space

    CERN Document Server

    Obata, Nobuaki

    1994-01-01

    White Noise Calculus is a distribution theory on Gaussian space, proposed by T. Hida in 1975. This approach enables us to use pointwise defined creation and annihilation operators as well as the well-established theory of nuclear space.This self-contained monograph presents, for the first time, a systematic introduction to operator theory on fock space by means of white noise calculus. The goal is a comprehensive account of general expansion theory of Fock space operators and its applications. In particular,first order differential operators, Laplacians, rotation group, Fourier transform and their interrelations are discussed in detail w.r.t. harmonic analysis on Gaussian space. The mathematical formalism used here is based on distribution theory and functional analysis , prior knowledge of white noise calculus is not required.

  9. Electrochemically deposited hybrid nickel-cobalt hexacyanoferrate nanostructures for electrochemical supercapacitors

    International Nuclear Information System (INIS)

    Safavi, A.; Kazemi, S.H.; Kazemi, H.

    2011-01-01

    Highlights: → Nanostructured hybrid nickel-cobalt hexacyanoferrate is used in supercapacitors. → A high capacitance (765 F g -1 ) is obtained at a specific current of 0.2 A g -1 . → Long cycle-life and excellent stability are demonstrated during 1000 cycles. - Abstract: This study describes the use of electrodeposited nanostructured hybrid nickel-cobalt hexacyanoferrate in electrochemical supercapacitors. Herein, various compositions of nickel and cobalt hexacyanoferrates (Ni/CoHCNFe) nanostructures are electrodeposited on an inexpensive stainless steel substrate using cyclic voltammetric (CV) method. The morphology of the electrodeposited nanostructures is studied using scanning electron microscopy, while their electrochemical characterizations are investigated using CV, galvanostatic charge and discharge and electrochemical impedance spectroscopy. The results show that the nanostructures of hybrid metal cyanoferrate, shows a much higher capacitance (765 F g -1 ) than those obtained with just nickel hexacyanoferrate (379 F g -1 ) or cobalt hexacyanoferrate (277 F g -1 ). Electrochemical impedance spectroscopy results confirm the favorable capacitive behavior of the electrodeposited materials. The columbic efficiency is approximately 95% based on the charge and discharge experiments. Long cycle-life and excellent stability of the nanostructured materials are also demonstrated during 1000 cycles.

  10. Electrochemically deposited hybrid nickel-cobalt hexacyanoferrate nanostructures for electrochemical supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Safavi, A., E-mail: safavi@chem.susc.ac.ir [Department of Chemistry, College of Sciences, Shiraz University, Shiraz 71454 (Iran, Islamic Republic of); Nanotechnology Research Institute, Shiraz University, Shiraz (Iran, Islamic Republic of); Kazemi, S.H., E-mail: habibkazemi@iasbs.ac.ir [Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731 (Iran, Islamic Republic of); Kazemi, H. [Department of Chemistry, College of Sciences, Shiraz University, Shiraz 71454 (Iran, Islamic Republic of)

    2011-10-30

    Highlights: > Nanostructured hybrid nickel-cobalt hexacyanoferrate is used in supercapacitors. > A high capacitance (765 F g{sup -1}) is obtained at a specific current of 0.2 A g{sup -1}. > Long cycle-life and excellent stability are demonstrated during 1000 cycles. - Abstract: This study describes the use of electrodeposited nanostructured hybrid nickel-cobalt hexacyanoferrate in electrochemical supercapacitors. Herein, various compositions of nickel and cobalt hexacyanoferrates (Ni/CoHCNFe) nanostructures are electrodeposited on an inexpensive stainless steel substrate using cyclic voltammetric (CV) method. The morphology of the electrodeposited nanostructures is studied using scanning electron microscopy, while their electrochemical characterizations are investigated using CV, galvanostatic charge and discharge and electrochemical impedance spectroscopy. The results show that the nanostructures of hybrid metal cyanoferrate, shows a much higher capacitance (765 F g{sup -1}) than those obtained with just nickel hexacyanoferrate (379 F g{sup -1}) or cobalt hexacyanoferrate (277 F g{sup -1}). Electrochemical impedance spectroscopy results confirm the favorable capacitive behavior of the electrodeposited materials. The columbic efficiency is approximately 95% based on the charge and discharge experiments. Long cycle-life and excellent stability of the nanostructured materials are also demonstrated during 1000 cycles.

  11. Random Correlation Matrix and De-Noising

    OpenAIRE

    Ken-ichi Mitsui; Yoshio Tabata

    2006-01-01

    In Finance, the modeling of a correlation matrix is one of the important problems. In particular, the correlation matrix obtained from market data has the noise. Here we apply the de-noising processing based on the wavelet analysis to the noisy correlation matrix, which is generated by a parametric function with random parameters. First of all, we show that two properties, i.e. symmetry and ones of all diagonal elements, of the correlation matrix preserve via the de-noising processing and the...

  12. A mathematical model of the current density distribution in electrochemical cells - AUTHORS’ REVIEW

    Directory of Open Access Journals (Sweden)

    PREDRAG M. ŽIVKOVIĆ

    2011-06-01

    Full Text Available An approach based on the equations of electrochemical kinetics for the estimation of the current density distribution in electrochemical cells is presented. This approach was employed for a theoretical explanation of the phenomena of the edge and corner effects. The effects of the geometry of the system, the kinetic parameters of the cathode reactions and the resistivity of the solution are also discussed. A procedure for a complete analysis of the current distribution in electrochemical cells is presented.

  13. Measurement and Analysis of the Noise Radiated by Low Mach Number Centrifugal Blowers.

    Science.gov (United States)

    Yeager, David Marvin

    An investigation was performed of the broad band, aerodynamically generated noise in low tip-speed Mach number, centrifugal air moving devices. An interdisciplinary experimental approach was taken which involved investigation of the aerodynamic and acoustic fields, and their mutual relationship. The noise generation process was studied using two experimental vehicles: (1) a scale model of a homologous family of centrifugal blowers typical of those used to cool computer and business equipment, and (2) a single blade from a centrifugal blower impeller placed in a known, controllable flow field. The radiation characteristics of the model blower were investigated by measuring the acoustic intensity distribution near the blower inlet and comparing it with the intensity near the inlet to an axial flow fan. Results showed that the centrifugal blower is a distributed, random noise source, unlike an axial fan which exhibited the effects of a coherent, interacting source distribution. Aerodynamic studies of the flow field in the inlet and at the discharge to the rotating impeller were used to assess the mean flow distribution through the impeller blade channels and to identify regions of excessive turbulence near the rotating blade row. Both circumferential and spanwise mean flow nonuniformities were identified along with a region of increased turbulence just downstream of the scroll cutoff. The fluid incidence angle, normally taken as an indicator of blower performance, was estimated from mean flow data as deviating considerably from an ideal impeller design. An investigation of the noise radiated from the single, isolated airfoil was performed using modern correlation and spectral analysis techniques. Radiation from the single blade in flow was characterized using newly developed expressions for the correlation area and the dipole source strength per unit area, and from the relationship between the blade surface pressure and the incident turbulent flow field. Results

  14. Background noise spectra of global seismic stations

    Energy Technology Data Exchange (ETDEWEB)

    Wada, M.M.; Claassen, J.P.

    1996-08-01

    Over an extended period of time station noise spectra were collected from various sources for use in estimating the detection and location performance of global networks of seismic stations. As the database of noise spectra enlarged and duplicate entries became available, an effort was mounted to more carefully select station noise spectra while discarding others. This report discusses the methodology and criteria by which the noise spectra were selected. It also identifies and illustrates the station noise spectra which survived the selection process and which currently contribute to the modeling efforts. The resulting catalog of noise statistics not only benefits those who model network performance but also those who wish to select stations on the basis of their noise level as may occur in designing networks or in selecting seismological data for analysis on the basis of station noise level. In view of the various ways by which station noise were estimated by the different contributors, it is advisable that future efforts which predict network performance have available station noise data and spectral estimation methods which are compatible with the statistics underlying seismic noise. This appropriately requires (1) averaging noise over seasonal and/or diurnal cycles, (2) averaging noise over time intervals comparable to those employed by actual detectors, and (3) using logarithmic measures of the noise.

  15. Noise power spectrum of the fixed pattern noise in digital radiography detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik, E-mail: dskim@hufs.ac.kr [Department of Electronics Engineering, Hankuk University of Foreign Studies, Gyeonggi-do 449-791 (Korea, Republic of); Kim, Eun [R& D Center, DRTECH Co., Gyeonggi-do 13558 (Korea, Republic of)

    2016-06-15

    Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain

  16. Chaos Noise on Phase of Van Der Pol Oscillator

    Directory of Open Access Journals (Sweden)

    Xian He Huang

    2010-12-01

    Full Text Available Phase noise is the most important parameter in many oscillators. In this paper, based on nonlinear stochastic differential equation for phase noise analysis approach is proposed. And then discusses and compares the influence of two different sources of noise in the Van Der Pol oscillator adopted this method. One source of noise is a white noise process, which is a genuinely stochastic process; the other source of noise is actually a deterministic system, which exhibits chaotic behavior in some regions. The behavior of the oscillator under different conditions is investigated numerically. It is shown that the phase noise of the oscillator is affected more by noise arising from chaos than by noise arising from the genuine stochastic process at the same noise intensity.

  17. New Techniques for Thermo-electrochemical Analysis of Lithium-ion Batteries for Space Applications

    Science.gov (United States)

    Walker, William; Ardebili, H.

    2013-01-01

    The overall goal of this study was achieved: Replicated the numerical assessment performed by Chen et. al. (2005). Displayed the ability of Thermal Desktop to be coupled with thermo-electrochemical analysis techniques. such that the local heat generated on the cells is a function of the model itself using logic blocks and arrays. Differences in the TD temperature vs. depth of discharge profiles and Chen's was most likely due to differences in two primary areas: Contact regions and conductance values. Differences in density and specific heat values. center dot The model results are highly dependent on the accuracy of the material properties with respect to the multiple layers of an individual cell.

  18. RNA aptamer-based electrochemical biosensor for selective and label-free analysis of dopamine

    DEFF Research Database (Denmark)

    Farjami, Elahe; Campos, Rui; Nielsen, Jesper Sejrup

    2013-01-01

    , including dopamine precursors and metabolites and other neurotransmitters (NT). Here we report an electrochemical RNA aptamer-based biosensor for analysis of dopamine in the presence of other NT. The biosensor exploits a specific binding of dopamine by the RNA aptamer, immobilized at a cysteamine......, norepinephrine, 3,4-dihydroxy-phenylalanine (l-DOPA), 3,4-dihydroxyphenylacetic acid (DOPAC), methyldopamine, and tyramine, which gave negligible signals under conditions of experiments (electroanalysis at 0.185 V vs Ag/AgCl). The interference from ascorbic and uric acids was eliminated by application...... as a general strategy not to restrict the conformational freedom and binding properties of surface-bound aptamers and, thus, be applicable for the development of other aptasensors...

  19. Variation and stability in Dutch noise policy: an analysis of dominant advocacy coalitions

    NARCIS (Netherlands)

    Weber, M.; Driessen, P.P.J.; Schueler, B.J.; Runhaar, H.A.C.

    2013-01-01

    Noise exposure has harmful effects on human health. Despite policy on the prevention and reduction of noise, the environmental burden is increasing, specifically due to road traffic noise. Noise policy in the Netherlands is organised in a rather complex way, with different legal frameworks for the

  20. Can weekly noise levels of urban road traffic, as predominant noise source, estimate annual ones?

    Science.gov (United States)

    Prieto Gajardo, Carlos; Barrigón Morillas, Juan Miguel; Rey Gozalo, Guillermo; Vílchez-Gómez, Rosendo

    2016-11-01

    The effects of noise pollution on human quality of life and health were recognised by the World Health Organisation a long time ago. There is a crucial dilemma for the study of urban noise when one is looking for proven methodologies that can allow, on the one hand, an increase in the quality of predictions, and on the other hand, saving resources in the spatial and temporal sampling. The temporal structure of urban noise is studied in this work from a different point of view. This methodology, based on Fourier analysis, is applied to several measurements of urban noise, mainly from road traffic and one-week long, carried out in two cities located on different continents and with different sociological life styles (Cáceres, Spain and Talca, Chile). Its capacity to predict annual noise levels from weekly measurements is studied. The relation between this methodology and the categorisation method is also analysed.