WorldWideScience

Sample records for electrochemical noise analysis

  1. Advantages of Wavelet analysis compared to Fourier analysis for the interpretation of electrochemical noise

    International Nuclear Information System (INIS)

    Espada, L.; Sanjurjo, M.; Urrejola, S.; Bouzada, F.; Rey, G.; Sanchez, A.

    2003-01-01

    Given its simplicity and low cost compared to other types of methodologies, the measurement and interpretation of Electrochemical Noise, is consolidating itself as one of the analysis methods most frequently used for the interpretation of corrosion. As the technique is still evolving, standard treatment methodologies for data retrieved in experiments do not exist yet. To date, statistical analysis and the Fourier analysis are commonly used in order to establish the parameters that may characterize the recording of potential and current electrochemical noise. This study introduces a new methodology based on wavelet analysis and presents its advantages with regards to the Fourier analysis in distinguishes periodical and non-periodical variations in the signal power in time and frequency, as opposed to the Fourier analysis that only considers the frequency. (Author) 15 refs

  2. Corrosion detection of carbon steel in water/oil two phases environment by electrochemical noise analysis

    International Nuclear Information System (INIS)

    Gusmano, G.; Montesperelli, G.; De Grandis, A.

    1998-01-01

    The aim of this paper is to demonstrate the effectiveness of the electrochemical noise analysis to detect the onset of corrosion phenomena in a very high resistivity medium. Tests were carried out on carbon steel electrodes immersed in a water/mineral oil two phases environment with high concentration of CO 2 , different aqueous/organic phase ratio, sulphide content between 0 and 0.5 g/l and pH between 1 and 5. The evolution of corrosion phenomena were followed by collecting current and potential noise between three nominally identical electrodes. The noise data were analysed in the time and in the frequency domain. In spite of a great loss of sensitivity of the method with respect to tests performed in aqueous solution, the data indicate a good agreement between the standard deviations and the power level of power spectra density (PSD) of current and potential noise signals and corrosion rates by means of weight loss. The values of the PSD slope, indicate the form of corrosion. The effect of water/oil ratio, sulphide concentration and pH on the corrosion rate was determined. Finally two methods to increase the sensitivity of the electrochemical noise are proposed. (orig.)

  3. Application of spectral analysis of the electrochemical noise to the investigation of aluminium alloy pitting corrosion

    International Nuclear Information System (INIS)

    Bataillon, Christian

    1987-01-01

    The objective of this research is to decode (at least partially) the nature of the information contained in the electrochemical noise associated with the pitting corrosion phenomenon in aluminium alloys. After a general presentation of aluminium and its alloys and a report of a bibliographical study on the electrochemical noise, the author gives an overview of a theoretical approach of stochastic phenomena, and of an experimental approach. Then, the experimental investigation of the electrochemical noise in the case of pitting corrosion leads to a noise control law, to a study of the structure of pitting growth, and to the elaboration of a procedure of assessment of spectral characteristics of this noise. The author reports a systematic study of the electrochemical noise with respect to the parameters of the control law. Results allow a quantitative characterization of pitting corrosion resistance of the studied alloys, notably by using the kinetic aspect of pitting growth and the structure of pitting corrosion. The author discusses the physicochemical nature of random fluctuations which build up the noise. He proposes a more precise explanation of phenomena related to initiation and propagation of pitting corrosion on aluminium alloys in marine environment [fr

  4. Electrochemical Noise Chaotic Analysis of NiCoAg Alloy in Hank Solution

    Directory of Open Access Journals (Sweden)

    D. Bahena

    2011-01-01

    Full Text Available The potential and current oscillations during corrosion of NiCoAg alloy in Hank solution were studied. Detailed nonlinear fractal analyses were used to characterize complex time series clearly showing that the irregularity in these time series corresponds to deterministic chaos rather than to random noise. The chaotic oscillations were characterized by power spectral densities, phase space, and Lyapunov exponents. Electrochemical impedance was also applied the fractal dimensions for the corroded surface was obtained, and a corrosion mechanism was proposed.

  5. Electrochemical analysis

    International Nuclear Information System (INIS)

    Hwang, Hun

    2007-02-01

    This book explains potentiometry, voltametry, amperometry and basic conception of conductometry with eleven chapters. It gives the specific descriptions on electrochemical cell and its mode, basic conception of electrochemical analysis on oxidation-reduction reaction, standard electrode potential, formal potential, faradaic current and faradaic process, mass transfer and overvoltage, potentiometry and indirect potentiometry, polarography with TAST, normal pulse and deferential pulse, voltammetry, conductometry and conductometric titration.

  6. Managing Electrochemical Noise Data by Exception Application of an On Line EN Data Analysis Technique to Data From a High Level Nuclear Waste Tank

    International Nuclear Information System (INIS)

    EDGEMON, G.L.

    2003-01-01

    Electrochemical noise has been used a t the Hanford Site for a number of years to monitor in real time for pitting corrosion and stress corrosion cracking (SCC) mechanisms in high level nuclear waste tanks. Currently the monitoring technique has only been implemented on three of the 177 underground storage tanks on the site. Widespread implementation of the technique has been held back for of a number of reasons, including issues around managing the large volume of data associated with electrochemical noise and the complexity of data analysis. Expert review of raw current and potential measurements is the primary form of data analysis currently used at the Hanford site. This paper demonstrates the application of an on-line data filtering and analysis technique that could allow data from field applications of electrochemical noise to be managed by exception, transforming electrochemical noise data into a process parameter and focusing data analysis efforts on the important data. Results of the analysis demonstrate a data compression rate of 95%; that is, only 5% of the data would require expert analysis if such a technique were implemented. It is also demonstrated that this technique is capable of identifying key periods where localized corrosion activity is apparent

  7. Electrochemical corrosion potential and noise measurement in high temperature water

    International Nuclear Information System (INIS)

    Fong, Clinton; Chen, Yaw-Ming; Chu, Fang; Huang, Chia-Shen

    2000-01-01

    Hydrogen water chemistry (HWC) is one of the most important methods in boiling water reactor(BWR) system to mitigate and prevent stress corrosion cracking (SCC) problems of stainless steel components. Currently, the effectiveness of HWC in each BWR is mainly evaluated by the measurement of electrochemical corrosion potentials (ECP) and on-line monitoring of SCC behaviors of stainless steels. The objective of this work was to evaluate the characteristics and performance of commercially available high temperature reference electrodes. In addition, SCC monitoring technique based on electrochemical noise analysis (ECN) was also tested to examine its crack detection capability. The experimental work on electrochemical corrosion potential (ECP) measurements reveals that high temperature external Ag/AgCl reference electrode of highly dilute KCl electrolyte can adequately function in both NWC and HWC environments. The high dilution external Ag/AgCl electrode can work in conjunction with internal Ag/AgCl reference electrode, and Pt electrode to ensure the ECP measurement reliability. In simulated BWR environment, the electrochemical noise tests of SCC were carried out with both actively and passively loaded specimens of type 304 stainless steel with various electrode arrangements. From the coupling current and corrosion potential behaviors of the passive loading tests during immersion test, it is difficult to interpret the general state of stress corrosion cracking based on the analytical results of overall current and potential variations, local pulse patterns, statistical characteristics, or power spectral density of electrochemical noise signals. However, more positive SCC indication was observed in the power spectral density analysis. For aqueous environments of high solution impedance, successful application of electrochemical noise technique for SCC monitoring may require further improvement in specimen designs and analytical methods to enhance detection sensitivity

  8. Detection of localized and general corrosion of mild steel in simulated defense nuclear waste solutions using electrochemical noise analysis

    International Nuclear Information System (INIS)

    Edgemon, G.L.; Ohl, P.C.; Bell, G.E.C.; Wilson, D.F.

    1995-12-01

    Underground waste tanks fabricated from mild steel store more than 60 million gallons of radioactive waste from 50 years of weapons production. Leaks are suspected in a significant number of tanks. The probable modes of corrosion failures are reported to be localized corrosion (e.g. nitrate stress corrosion cracking and pitting). The use of electrochemical noise (EN) for the monitoring and detection of localized corrosion processes has received considerable attention and application over the last several years. Proof of principle laboratory tests were conducted to verify the capability of EN evaluation to detect localized corrosion and to compare the predictions of general corrosion obtained from EN with those derived from other sources. Simple, pre-fabricated flat and U-bend specimens of steel alloys A516-Grade 60 (UNS K02100) and A537-CL 1 (UNS K02400) were immersed in temperature controlled simulated waste solutions. The simulated waste solution was either 5M NaNO 3 with 0.3M NaOH at 90 C or 11M NaNO 3 with 0.15M NaOH at 95 C. The electrochemical noise activity from the specimens was monitored and recorded for periods ranging between 140 and 240 hours. At the end of each test period, the specimens were metallographically examined to correlated EN data with corrosion damage

  9. Analysis of electrochemical noise (ECN) data in time and frequency domain for comparison corrosion inhibition of some azole compounds on Cu in 1.0 M H2SO4 solution

    Science.gov (United States)

    Ramezanzadeh, B.; Arman, S. Y.; Mehdipour, M.; Markhali, B. P.

    2014-01-01

    In this study, the corrosion inhibition properties of two similar heterocyclic compounds namely benzotriazole (BTA) and benzothiazole (BNS) inhibitors on copper in 1.0 M H2SO4 solution were studied by electrochemical techniques as well as surface analysis. The results showed that corrosion inhibition of copper largely depends on the molecular structure and concentration of the inhibitors. The effect of DC trend on the interpretation of electrochemical noise (ECN) results in time domain was evaluated by moving average removal (MAR) method. Accordingly, the impact of square and Hanning window functions as drift removal methods in frequency domain was studied. After DC trend removal, a good trend was observed between electrochemical noise (ECN) data and the results obtained from EIS and potentiodynamic polarization. Furthermore, the shot noise theory in frequency domain was applied to approach the charge of each electrochemical event (q) from the potential and current noise signals.

  10. Electrochemical noise from corroding carbon steel and aluminium

    International Nuclear Information System (INIS)

    Singh, P.R.; Gaonkar, K.B.; De, P.K.; Banerjee, S.

    1997-05-01

    Electrochemical noise measurements were conducted on carbon steel and aluminium in sodium chloride solutions. Noise parameters like standard deviation of potential and current, noise resistance, pitting index, noise power were studied for the purpose of measuring corrosion rate. These parameters compared well with the corrosion rate. Pitting index was not very reliable. Current noise was more close to the corrosion rates. General corrosion gave rise to white noise type of power spectrum while flicker noise type of spectrum was obtained from pitting attack. Sodium nitrite is shown to inhibit the corrosion of carbon steel. Aluminium corrodes in the early period of exposure and passivates during long exposure

  11. A study of passivation/depassivation of carbon steel; electrochemical impedance spectrocopy vs. potential noise fluctuations

    International Nuclear Information System (INIS)

    Roberge, P.R.; Halliop, E.; Sastri, V.S.

    1992-01-01

    A technique based on recording corrosion potential fluctuations generated by corroding electrodes was used under open-circuit conditions to study passivation and depassivation of carbon steel. Quantification of the electrochemical signal in terms of the pitting corrosion rate has been attempted. The amplitude of electrochemical noise signals was analyzed under different pitting conditions and correlated to polarization resistance values obtained from the electrochemical impedance spectra. The automatic statistical data analysis of electrochemical impedance data points has been successfully applied to calculate polarization resistance values and other interesting characteristics of such measurements

  12. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  13. The use of skewness, kurtosis and neural networks for determining corrosion mechanism from electrochemical noise data

    International Nuclear Information System (INIS)

    Reid, S.; Bell, G.E.C.; Edgemon, G.L.

    1998-01-01

    This paper describes the work undertaken to de-skill the complex procedure of determining corrosion mechanisms derived from electrochemical noise data. The use of neural networks is discussed and applied to the real time generated electrochemical noise data files with the purpose of determining characteristics particular to individual types of corrosion mechanisms. The electrochemical noise signals can have a wide dynamic range and various methods of raw data pre-processing prior to neural network analysis were investigated. Normalized data were ultimately used as input to the final network analysis. Various network schemes were designed, trained and tested. Factors such as the network learning schedule and network design were considered before a final network was implemented to achieve a solution. Neural networks trained using general and localized corrosion data from various material environment systems were used to analyze data from simulated nuclear waste tank environments with favorable results

  14. Modeling of pH Dependent Electrochemical Noise in Ion Sensitive Field Effect Transistors ISFET

    Directory of Open Access Journals (Sweden)

    M. P. Das

    2013-02-01

    Full Text Available pH ISFETs are very important sensor for in vivo continuous monitoring application of physiological and environmental system. The accuracy of Ion Sensitive Field Effect Transistor (ISFET output measurement is greatly affected by the presences of noise, drift and slow response of the device. Although the noise analysis of ISFET so far performed in different literature relates only to sources originated from Field Effect Transistor (FET structure which are almost constant for a particular device, the pH dependent electrochemical noise has not been substantially explored and analyzed. In this paper we have investigated the low frequency pH dependent electrochemical noise that originates from the ionic conductance of the electrode-electrolyte-Field Effect Transistor structure of the device and that the noise depends on the concentration of the electrolyte and 1/f in nature. The statistical and frequency analysis of this electrochemical noise of a commercial ISFET sensor, under room temperature has been performed for six different pH values ranging from pH2 to pH9.2. We have also proposed a concentration dependent a/f & b/f2 model of the noise with different values of the coefficients a, b.

  15. Comparison of susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys in neutral chloride solutions using electrochemical noise analysis

    International Nuclear Information System (INIS)

    Na, Kyung-Hwan; Pyun, Su-Il

    2008-01-01

    The susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys was investigated in aqueous neutral chloride solution for the purpose of comparison using electrochemical noise measurement. The experimentally measured electrochemical noises were analysed based upon the combined stochastic theory and shot-noise theory using the Weibull distribution function. From the occurrence of two linear regions on one Weibull probability plot, it was suggested that there existed two stochastic processes of uniform corrosion and pitting corrosion; pitting corrosion was distinguished from uniform corrosion in terms of the frequency of events in the stochastic analysis. Accordingly, the present analysis method allowed us to investigate pitting corrosion independently. The susceptibility to pitting corrosion was appropriately evaluated by determining pit embryo formation rate in the stochastic analysis. The susceptibility was decreased in the following order: AA2024-T4 (the naturally aged condition), AA7475-T761 (the overaged condition) and AA7075-T651 (the near-peak-aged condition)

  16. Electrochemical Sensors for Clinic Analysis

    Directory of Open Access Journals (Sweden)

    Guang Li

    2008-03-01

    Full Text Available Demanded by modern medical diagnosis, advances in microfabrication technology have led to the development of fast, sensitive and selective electrochemical sensors for clinic analysis. This review addresses the principles behind electrochemical sensor design and fabrication, and introduces recent progress in the application of electrochemical sensors to analysis of clinical chemicals such as blood gases, electrolytes, metabolites, DNA and antibodies, including basic and applied research. Miniaturized commercial electrochemical biosensors will form the basis of inexpensive and easy to use devices for acquiring chemical information to bring sophisticated analytical capabilities to the non-specialist and general public alike in the future.

  17. Destructive impact of molecular noise on nanoscale electrochemical oscillators

    Science.gov (United States)

    Cosi, Filippo G.; Krischer, Katharina

    2017-06-01

    We study the loss of coherence of electrochemical oscillations on meso- and nanosized electrodes with numeric simulations of the electrochemical master equation for a prototypical electrochemical oscillator, the hydrogen peroxide reduction on Pt electrodes in the presence of halides. On nanoelectrodes, the electrode potential changes whenever a stochastic electron-transfer event takes place. Electrochemical reaction rate coefficients depend exponentially on the electrode potential and become thus fluctuating quantities as well. Therefore, also the transition rates between system states become time-dependent which constitutes a fundamental difference to purely chemical nanoscale oscillators. Three implications are demonstrated: (a) oscillations and steady states shift in phase space with decreasing system size, thereby also decreasing considerably the oscillating parameter regions; (b) the minimal number of molecules necessary to support correlated oscillations is more than 10 times as large as for nanoscale chemical oscillators; (c) the relation between correlation time and variance of the period of the oscillations predicted for chemical oscillators in the weak noise limit is only fulfilled in a very restricted parameter range for the electrochemical nano-oscillator.

  18. Statistical analysis of electrochemical noise records at aluminium corrosion; Analisis estadistico de los registros de ruido electroquimico obtenidos en la corrosion del aluminio

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, A.; Sanjurjo, M.; Bouzada, F.; Urrejola, S.

    2005-07-01

    Given that the experimental signals obtained in an electrochemical noise measurement, ENM, are recorded over a discrete time period, the most direct way of analysing them will be in the time domain resorting to starting to statistical methods. These can be classified into two groups according to use; those which attempt to quantify the degree of the corrosion process (standard deviations, statistical power); and those which attempt to provide information on the corrosion mechanism (based on the assumption that the shape of the time records is a reflection of itself). Among the later the use of the average, the skewness and the kurtosis of the signals or the pitting index can be pointed out as being able to reflect the changes in the corrosion mechanism. Noise resistance stands out above all these parameters. In this work has undertaken the statistical treatment of ENM data obtained by subjecting aluminium to three electrolytes that provoke several types of corrosion in it: passivity, pitting corrosion and generalized corrosion. (Author) 22 refs.

  19. Electrochemical noise based corrosion monitoring: FY 2001 final report

    International Nuclear Information System (INIS)

    EDGAR, C.

    2001-01-01

    Underground storage tanks made of mild steel are used to contain radioactive waste generated by plutonium production at the Hanford Site. Corrosion of the walls of these tanks is a major issue. Corrosion monitoring and control are currently provided at the Hanford Site through a waste chemistry sampling and analysis program. In this process, tank waste is sampled, analyzed and compared to a selection of laboratory exposures of coupons in simulated waste. Tank wall corrosion is inferred by matching measured tank chemistries to the results of the laboratory simulant testing. This method is expensive, time consuming, and does not yield real-time data. Corrosion can be monitored through coupon exposure studies and a variety of electrochemical techniques. A small number of these techniques have been tried at Hanford and elsewhere within the DOE complex to determine the corrosivity of nuclear waste stored in underground tanks [1]. Coupon exposure programs, linear polarization resistance (LPR), and electrical resistance techniques have all been tried with limited degrees of success. These techniques are most effective for monitoring uniform corrosion, but are not well suited for early detection of localized forms of corrosion such as pitting and stress corrosion cracking (SCC). Pitting and SCC have been identified as the most likely modes of corrosion failure for Hanford Double Shell Tanks (DST'S) [2-3]. Over the last 20 years, a new corrosion monitoring system has shown promise in detecting localized corrosion and measuring uniform corrosion rates in process industries [4-20]. The system measures electrochemical noise (EN) generated by corrosion. The term EN is used to describe low frequency fluctuations in current and voltage associated with corrosion. In their most basic form, EN-based corrosion monitoring systems monitor and record fluctuations in current and voltage over time from electrodes immersed in an environment of interest. Laboratory studies and field

  20. Electrochemical Analysis of Neurotransmitters

    Science.gov (United States)

    Bucher, Elizabeth S.; Wightman, R. Mark

    2015-07-01

    Chemical signaling through the release of neurotransmitters into the extracellular space is the primary means of communication between neurons. More than four decades ago, Ralph Adams and his colleagues realized the utility of electrochemical methods for the study of easily oxidizable neurotransmitters, such as dopamine, norepinephrine, and serotonin and their metabolites. Today, electrochemical techniques are frequently coupled to microelectrodes to enable spatially resolved recordings of rapid neurotransmitter dynamics in a variety of biological preparations spanning from single cells to the intact brain of behaving animals. In this review, we provide a basic overview of the principles underlying constant-potential amperometry and fast-scan cyclic voltammetry, the most commonly employed electrochemical techniques, and the general application of these methods to the study of neurotransmission. We thereafter discuss several recent developments in sensor design and experimental methodology that are challenging the current limitations defining the application of electrochemical methods to neurotransmitter measurements.

  1. In situ characterization of natural pyrite bioleaching using electrochemical noise technique

    Science.gov (United States)

    Chen, Guo-bao; Yang, Hong-ying; Li, Hai-jun

    2016-02-01

    An in situ characterization technique called electrochemical noise (ECN) was used to investigate the bioleaching of natural pyrite. ECN experiments were conducted in four active systems (sulfuric acid, ferric-ion, 9k culture medium, and bioleaching solutions). The ECN data were analyzed in both the time and frequency domains. Spectral noise impedance spectra obtained from power spectral density (PSD) plots for different systems were compared. A reaction mechanism was also proposed on the basis of the experimental data analysis. The bioleaching system exhibits the lowest noise resistance of 0.101 MΩ. The bioleaching of natural pyrite is considered to be a bio-battery reaction, which distinguishes it from chemical oxidation reactions in ferric-ion and culture-medium (9k) solutions. The corrosion of pyrite becomes more severe over time after the long-term testing of bioleaching.

  2. Corrosion monitoring in a straw-fired power plant using an electrochemical noise probe

    DEFF Research Database (Denmark)

    Cappeln, Frederik Vilhelm; Bjerrum, Niels; Petrushina, Irina

    2007-01-01

    Electrochemical Noise Measurements have been carried out in situ in a straw-fired power plant using an experimental probe constructed from alumina and AlSl 347 steel. Based on a framework of controlled laboratory experiments it has been found that electrochemical noise has the unique ability...... to provide in-situ monitoring of intergranular corrosion in progress. The probe had a lifetime of two months. It was shown that down-time corrosion in the boiler was negligible. Electrochemical noise data indicated that metal temperatures around 590 degrees C should be avoided as the intergranular corrosion...

  3. Electrochemical noise transient analysis for 316 and Duplex 2205 stainless steels in NaCl and FeCl; Analisis de los transitorios de ruido electroquimico para aceros inoxidables 316 Y - DUPLEX 2205 en NaCl Y FeCl

    Energy Technology Data Exchange (ETDEWEB)

    Almeraya-Calderaon, F.; Estupinan, F.; Zambrano, P.; Martinez-Villafane, A.; Borunda, A.; Colas, R.; Gaona-Tiburcio, C.

    2012-11-01

    This work shows the results obtained from electrochemical noise measurements for different materials exhibiting pitting corrosion. The transients presented in the potential and current time, correlates with the scanning electron microscopy (SEM) surface analysis. Electrochemical measurements were made at different exposure times to obtain the correlation. The materials used were stainless steel austenitic 316 and duplex 2205, immersed in ferric chloride (FeCl3) and sodium chloride (NaCl) electrolytes. SEM analysis shows that the transients observed in the time series, really correspond to the activity of pit nucleation developed over the surface of the electrodes. (Author) 31 refs.

  4. Nanoelectrode array for electrochemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yelton, William G [Sandia Park, NM; Siegal, Michael P [Albuquerque, NM

    2009-12-01

    A nanoelectrode array comprises a plurality of nanoelectrodes wherein the geometric dimensions of the electrode controls the electrochemical response, and the current density is independent of time. By combining a massive array of nanoelectrodes in parallel, the current signal can be amplified while still retaining the beneficial geometric advantages of nanoelectrodes. Such nanoelectrode arrays can be used in a sensor system for rapid, non-contaminating field analysis. For example, an array of suitably functionalized nanoelectrodes can be incorporated into a small, integrated sensor system that can identify many species rapidly and simultaneously under field conditions in high-resistivity water, without the need for chemical addition to increase conductivity.

  5. Noise and vibration analysis system

    International Nuclear Information System (INIS)

    Johnsen, J.R.; Williams, R.L.

    1985-01-01

    The analysis of noise and vibration data from an operating nuclear plant can provide valuable information that can identify and characterize abnormal conditions. Existing plant monitoring equipment, such as loose parts monitoring systems (LPMS) and neutron flux detectors, may be capable of gathering noise data, but may lack the analytical capability to extract useful meanings hidden in the noise. By analyzing neutron noise signals, the structural motion and integrity of core components can be assessed. Computer analysis makes trending of frequency spectra within a fuel cycle and from one cycle to another a practical means of core internals monitoring. The Babcock and Wilcox Noise and Vibration Analysis System (NVAS) is a powerful, compact system that can automatically perform complex data analysis. The system can acquire, process, and store data, then produce report-quality plots of the important parameter. Software to perform neutron noise analysis and loose parts analysis operates on the same hardware package. Since the system is compact, inexpensive, and easy to operate, it allows utilities to perform more frequency analyses without incurring high costs and provides immediate results

  6. Reactor surveillance by noise analysis

    International Nuclear Information System (INIS)

    Ciftcioglu, Ozer

    1988-01-01

    A real-time noise analysis system is designed for the TRIGA reactor at Istanbul Technical University. By means of the noise techniques, reactor surveillance is performed together with failure diagnosis. The fast data processing is carried out by FFT in real-time so that malfunction or non-stationary operation of the reactor in long term can be identified by comparing the noise power spectra with the corresponding reference patterns while the decision making procedure is accomplished by the method of hypothesis testing. The system being computer based safety instrumentation involves CAMAC in conjunction with the RT-11 (PDP-11) single user dedicated environment. (author)

  7. Corrosion monitoring of the AA2024 alloy in NaCl solutions by electrochemical noise measurements

    International Nuclear Information System (INIS)

    Aballe, A.; Bethencourt, M.; Botana, F.J.; Marcos, M.; Rodriguez-Chacon, M.A.

    1998-01-01

    The behaviour of the AA2024 alloy against corrosion in 3.5% NaCl solution has been monitored. In this environment the alloy can be easily damaged under small anodic polarizations. Linear Polarization, electrochemical impedance, spectroscopy and electrochemical noise measurement have been used as experimental techniques. Data from ENM have been analyzed using statistical parameters and Chaos Theory. The results here obtained suggest that ENM is particularly useful to monitored systems that can be modified using other electrochemical techniques. (Author) 11 refs

  8. Electrochemical biosensors in pharmaceutical analysis

    Directory of Open Access Journals (Sweden)

    Eric de Souza Gil

    2010-09-01

    Full Text Available Given the increasing demand for practical and low-cost analytical techniques, biosensors have attracted attention for use in the quality analysis of drugs, medicines, and other analytes of interest in the pharmaceutical area. Biosensors allow quantification not only of the active component in pharmaceutical formulations, but also the analysis of degradation products and metabolites in biological fluids. Thus, this article presents a brief review of biosensor use in pharmaceutical analysis, focusing on enzymatic electrochemical sensors.Em virtude do aumento da demanda por técnicas analíticas simples e de baixo custo, os biossensores têm atraído a atenção para a análise de fármacos, medicamentos e outros analitos de interesse em controle de qualidade de medicamentos. Os biossensores permitem a quantificação não somente de princípio ativo em formulações farmacêuticas, mas também de produtos de degradação e metabólitos em fluídos biológicos, bem como análise de amostras de interesse clínico e industrial, além de possibilitar a determinação de enantiômeros. Desta forma, este artigo objetiva fazer uma breve revisão a respeito do emprego de biossensores em análise farmacêutica, com ênfase em sensores eletroquímicos enzimáticos.

  9. BWR noise spectra and application of noise analysis to FBR

    International Nuclear Information System (INIS)

    Nomura, T.

    1975-01-01

    Work related to noise analysis, in Tokyo Shibaura Electric Co. Ltd. (Toshiba) and Nippon Atomic Industry Group Co. Ltd. (NAIG) for the past several years is reviewed. After considering the Japan-United States Seminar on Reactor Noise Analysis in 1968, other subjects discussed were boiling water reactor noise analysis and work in relation to FBR. Parts of these are related to each other. For example, boiling detection and temperature fluctuations are problems pertinent to both fields. As the main problems in zero-power-reactor noise are now basically understood, only a brief description of the experiments involving the advanced two detector method is made. Focus is rather placed on the area of power plant noise. (author)

  10. Electrochemical noise measurements techniques and the reversing dc potential drop method applied to stress corrosion essays

    International Nuclear Information System (INIS)

    Aly, Omar Fernandes; Andrade, Arnaldo Paes de; MattarNeto, Miguel; Aoki, Idalina Vieira

    2002-01-01

    This paper aims to collect information and to discuss the electrochemical noise measurements and the reversing dc potential drop method, applied to stress corrosion essays that can be used to evaluate the nucleation and the increase of stress corrosion cracking in Alloy 600 and/or Alloy 182 specimens from Angra I Nuclear Power Plant. Therefore we will pretend to establish a standard procedure to essays to be realized on the new autoclave equipment on the Laboratorio de Eletroquimica e Corrosao do Departamento de Engenharia Quimica da Escola Politecnica da Universidade de Sao Paulo - Electrochemical and Corrosion Laboratory of the Chemical Engineering Department of Polytechnical School of Sao Paulo University, Brazil. (author)

  11. Analysis of electrochemical noise data in both time and frequency domains to evaluate the effect of ZnO nanopowder addition on the corrosion protection performance of epoxy coatings

    Directory of Open Access Journals (Sweden)

    H. Ashassi-Sorkhabi

    2016-11-01

    Full Text Available Epoxy–ZnO nanocomposite coatings have been developed for corrosion protection of steel. Structural characterization of the prepared nanocomposites was performed using scanning electron microscopy (SEM. The anti-corrosive properties of the coatings were evaluated by electrochemical noise (EN. On the basis of the EN results in both time and frequency domains, the nanocomposite material with low ZnO concentration (0.1% wt.% was found to be much superior in corrosion protection when tested in aqueous NaCl electrolyte. Finally, EIS measurements were carried out and the data fitted with suitable equivalent circuit. Resistance parameters obtained by both techniques were found to be in relatively good agreement.

  12. Electrochemical noise evaluation of anodized aluminum. Comparative study against corrosion behaviour in the atmosphere

    International Nuclear Information System (INIS)

    Betancourt, N.; Corvo, F.; Mendoza, A.; Simancas, J.; Morcillo, M.; Gonzalez, J. A.; Fragata, F.; Pena, J. J.; Sanchez de Villalaz, M.; Flores, S.; Almeida, E.; Rivero, S.; Rincon, O. T. de.

    2003-01-01

    The present work reports the evaluation of aluminum and anodized aluminum by electrochemical noise, as a part of the PATINE/CYTED project of the working group NS5. A visual examination is also made. The samples were exposed at several Ibero-American atmospheres up to 2 years of exposure. Different thickness of anodized aluminum were evaluated. The electrochemical potential noise of the 5 μm unexposed sample (pattern) showed a different behaviour to that showed by the other anodized specimens. This could be due to a slower sealed of the samples of higher thickness. The same behavior was observed on the samples exposed at the rural station. el Pardo. According to the visual examination, the samples of bare aluminum and those of anodized 5 μm thickness were the most affected by pitting corrosion in the highly polluted atmospheres. A good correlation between corrosion behaviour determined by visual examination and EN was obtained. (Author) 4 refs

  13. Application of a passive electrochemical noise technique to localized corrosion of candidate radioactive waste container materials

    International Nuclear Information System (INIS)

    Korzan, M.A.

    1994-05-01

    One of the key engineered barriers in the design of the proposed Yucca Mountain repository is the waste canister that encapsulates the spent fuel elements. Current candidate metals for the canisters to be emplaced at Yucca Mountain include cast iron, carbon steel, Incoloy 825 and titanium code-12. This project was designed to evaluate passive electrochemical noise techniques for measuring pitting and corrosion characteristics of candidate materials under prototypical repository conditions. Experimental techniques were also developed and optimized for measurements in a radiation environment. These techniques provide a new method for understanding material response to environmental effects (i.e., gamma radiation, temperature, solution chemistry) through the measurement of electrochemical noise generated during the corrosion of the metal surface. In addition, because of the passive nature of the measurement the technique could offer a means of in-situ monitoring of barrier performance

  14. A Plan to Develop and Demonstrate Electrochemical Noise Based Corrosion Monitoring Systems in Hanford Site Waste Tanks

    International Nuclear Information System (INIS)

    NORMAN, E.C.

    2000-01-01

    This document describes changes that need to be made to the site's authorization basis and technical concerns that need to be resolved before proceduralized use of Electrochemical Noise based corrosion monitoring systems is fully possible at the Hanford Site

  15. Treatment of electrochemical noise data by the Hilbert-Huang transform

    International Nuclear Information System (INIS)

    Rahier, A.

    2009-01-01

    Most of the classical approaches for treating electro-chemical noise (ECN) data suffer from the non-linear and non steady-state character of the delivered signal. Very often, the link between time and the local corrosion events supposedly responsible for ECN data signatures is lost during treatment, as is obvious when using the classical Fourier Transform (FT), followed by an analysis of the response in the frequency domain. In this particular case, the information directly related to the corrosion events is distributed into the full spectra, thereby preventing the operator to derive clear and precise conclusions. In 2005, we suggested an alternative data treatment based on the Hilbert-Huang transform (HHT). The latter keeps track of the time variable and copes with non-linear and non steady-state behaviours of the system under examination. In 2006, we demonstrated the applicability of the newly proposed data treatment in the case of ECN data collected under BWR (Boiling Water Reactor) conditions. In 2007, we collected additional ECN data and started a preliminary investigation of two mathematical restrictions that are susceptible to impair the interpretation of the results. We discovered a possible modification of the Hilbert transform allowing generating controlled phase shifts that are different from pi/2 as is always the case for the Hilbert transform

  16. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  17. Status of Database for Electrochemical Noise Based Corrosion Monitoring

    International Nuclear Information System (INIS)

    EDGEMON, G.L.

    1999-01-01

    Underground storage tanks made of mild steel are used to contain radioactive waste generated by plutonium production at the Hanford Site. Corrosion of the walls of these tanks is a major issue. Corrosion-related failure of waste tank walls could lead to the leakage of radioactive contaminants to the soil and groundwater. It is essential to monitor corrosion conditions of the tank walls to determine tank integrity and ensure safe waste storage until retrieval and final waste disposal can be accomplished. Corrosion monitoring/control is currently provided at the Hanford Site through a waste chemistry sampling and analysis program. In this process, tank waste is sampled, analyzed and compared to a selection of laboratory exposures of coupons in simulated waste. Tank wall corrosion is inferred by matching measured tank chemistries to the results of the laboratory simulant testing. This method is expensive, time consuming, and does not yield real-time data. A project to improve the Hanford Site's corrosion monitoring strategy was started in 1995

  18. Noise Analysis of MAIA System and Possible Noise Suppression

    Czech Academy of Sciences Publication Activity Database

    Švihlík, J.; Fliegel, K.; Koten, Pavel; Vítek, S.; Páta, P.

    2011-01-01

    Roč. 20, č. 1 (2011), s. 110-117 ISSN 1210-2512. [International Conference on Telecommunications and Signal Processing /33./ - TSP 2010. Baden near Vienna, 17.08.2010-20.08.2010] Institutional research plan: CEZ:AV0Z10030501 Keywords : MAIA * meteor * noise analysis Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 0.739, year: 2011

  19. Electrochemical biosensors in pharmaceutical analysis

    OpenAIRE

    Gil, Eric de Souza; Melo, Giselle Rodrigues de

    2010-01-01

    Given the increasing demand for practical and low-cost analytical techniques, biosensors have attracted attention for use in the quality analysis of drugs, medicines, and other analytes of interest in the pharmaceutical area. Biosensors allow quantification not only of the active component in pharmaceutical formulations, but also the analysis of degradation products and metabolites in biological fluids. Thus, this article presents a brief review of biosensor use in pharmaceutical analysis, fo...

  20. Problems, pitfalls, and probes: Welcome to the jungle of electrochemical noise technology

    International Nuclear Information System (INIS)

    Edgemon, G.L.

    1998-01-01

    The rise in electrochemical noise (EN) as a corrosion monitoring technique has resulted in unique problems associated with the field application of this method. Many issues relate to the design of the EN probe electrodes. The ability of an electrochemical noise monitoring system to identify and discriminate between localized corrosion mechanisms is related primarily to the capability of the probe to separate the corrosion cell anode from the corresponding cathode. Effectiveness of this separation is largely determined by the details of and the proper design of the probe that is in the environment of interest. No single probe design or geometry can be effectively use in every situation to monitor all types of corrosion. In this paper the authors focus on a case study and probe development history related to monitoring corrosion in an extremely hostile environment using EN. While the ultimate application of EN was and continues to be successful, the case study shows that patience and persistence was necessary to meet and properly implement the monitoring program. Other possible source of problems and frustration with implementing EN are also discussed

  1. Analysis of reactor noise; Analiza reaktorskih sumova

    Energy Technology Data Exchange (ETDEWEB)

    Velickovic, Lj [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1967-11-15

    This paper describes the theoretical model for interpretation of experimental results, experimental method for study of reactor noise at the RB reactor, numerical treatment of experimental results by correlation technique for analysis of reactor noise. A computer code was written to obtain autocorrelation function and spectral density function. Experimental results obtained by oscillator technique, pulse technique, and autocorrelation method are presented and discussed.

  2. Sensor response time monitoring using noise analysis

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Thie, J.A.; Upadhyaya, B.R.; Holbert, K.E.

    1988-01-01

    Random noise techniques in nuclear power plants have been developed for system surveillance and for analysis of reactor core dynamics. The noise signals also contain information about sensor dynamics, and this can be extracted using frequency, amplitude and time domain analyses. Even though noise analysis has been used for sensor response time testing in some nuclear power plants, an adequate validation of this method has never been carried out. This paper presents the results of limited work recently performed to examine the validity of the noise analysis for sensor response time testing in nuclear power plants. The conclusion is that noise analysis has the potential for detecting gross changes in sensor response but it cannot be used for reliable measurement of response time until more laboratory and field experience is accumulated. The method is more advantageous for testing pressure sensors than it is for temperature sensors. This is because: 1) for temperature sensors, a method called Loop Current Step Response test is available which is quantitatively more exact than noise analysis, 2) no method currently exists for on-line testing of pressure transmitters other than the Power-Interrupt test which is applicable only to force balance pressure transmitters, and 3) pressure sensor response time is affected by sensing line degradation which is inherently taken into account by testing with noise analysis. (author)

  3. Modeling of pH Dependent Electrochemical Noise in Ion Sensitive Field Effect Transistors ISFET

    OpenAIRE

    M. P. Das; M. Bhuyan

    2013-01-01

    pH ISFETs are very important sensor for in vivo continuous monitoring application of physiological and environmental system. The accuracy of Ion Sensitive Field Effect Transistor (ISFET) output measurement is greatly affected by the presences of noise, drift and slow response of the device. Although the noise analysis of ISFET so far performed in different literature relates only to sources originated from Field Effect Transistor (FET) structure which are almost constant for a particular devi...

  4. Reactor sensor surveillance using noise analysis

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Thie, J.A.; Upadhyaya, B.R.

    1986-01-01

    Reactor noise signals, as measured by neutron detectors and process sensors, contain information about the dynamics of the process and sensor characteristics. The extent of sensor characteristics that can be determined from such measurements depends on the sensor type, the property of the process noise exciting the sensor and its location. This paper addresses degradation monitoring of temperature and pressure sensors, analysis methods and results of application to operating pressurized water reactors. In addition, the use of noise analysis for monitoring of pressure sensing lines in nuclear power plants is discussed

  5. Noise elimination algorithm for modal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bao, X. X., E-mail: baoxingxian@upc.edu.cn [Department of Naval Architecture and Ocean Engineering, China University of Petroleum (East China), Qingdao 266580 (China); Li, C. L. [Key Laboratory of Marine Geology and Environment, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071 (China); Xiong, C. B. [The First Institute of Oceanography, State Oceanic Administration, Qingdao 266061 (China)

    2015-07-27

    Modal analysis is an ongoing interdisciplinary physical issue. Modal parameters estimation is applied to determine the dynamic characteristics of structures under vibration excitation. Modal analysis is more challenging for the measured vibration response signals are contaminated with noise. This study develops a mathematical algorithm of structured low rank approximation combined with the complex exponential method to estimate the modal parameters. Physical experiments using a steel cantilever beam with ten accelerometers mounted, excited by an impulse load, demonstrate that this method can significantly eliminate noise from measured signals and accurately identify the modal frequencies and damping ratios. This study provides a fundamental mechanism of noise elimination using structured low rank approximation in physical fields.

  6. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  7. Complexity in White Noise Analysis

    Science.gov (United States)

    Hida, Takeyuki

    We restrict our attention to random complex systems and discuss degree their degree of complexity based on a white noise. The white noise is realized as the time derivative of a Brownian motion B(t), and denoted by Ḃ(t). The collection {Ḃ(t)}, is a system of idealized elementary variables and at the same time the system is a stochastic representation of the time t, in other words it is time-oriented. Having expressed the given evolutional random phenomena in question in terms of the Ḃ(t), we introduce the notion of spectral multiplicity, which describes how much the phenomena are complex. The multiplicity is the number of cyclic subspaces that are spanned by the given random phenomena. Each cyclic subspace has further structure. Typical property is multiple Markov property, although this property appears only particular cases. As a related property, in fact as a characteristic of a complex system, one can speak of the time reversibility and irreversibility of certain random phenomena in terms of the white noise. We expect an irreversible random complex system may be decomposed into reversible systems.

  8. Noise estimation for remote sensing image data analysis

    Science.gov (United States)

    Du, Qian

    2004-01-01

    Noise estimation does not receive much attention in remote sensing society. It may be because normally noise is not large enough to impair image analysis result. Noise estimation is also very challenging due to the randomness nature of the noise (for random noise) and the difficulty of separating the noise component from the signal in each specific location. We review and propose seven different types of methods to estimate noise variance and noise covariance matrix in a remotely sensed image. In the experiment, it is demonstrated that a good noise estimate can improve the performance of an algorithm via noise whitening if this algorithm assumes white noise.

  9. Detection of crevice corrosion in AISI type 316LN stainless steel in presence of pseudomonas bacteria using electrochemical noise technique

    International Nuclear Information System (INIS)

    Pujar, M.G.; George, R.P.; Ramya, S.; Kamachi Mudali, U.

    2011-01-01

    Gram-negative pseudomonas sp. was used as the test organism for the biofilm formation and growth on 316 LN stainless and electrochemical noise (EN) monitoring studies, since this genus has been identified as the major biofilm former on stainless steels. EN studies were conducted for 21 days on the galvanically coupled specimens exposed to the dilute nutrient culture with pseudomonas sp. The visual records of the current potential EN, analysis of statistical and power spectral density (PSD) parameters of current and potential along with shot-noise parameters showed increase in the localized corrosion during initial 2-11 days exposure; thereafter the specimens showed passive behaviour. Raman spectra taken inside the pit for the specimen exposed for 21 days showed the peak corresponding to Cr 3+ ions signifying repassivation process. Similarly, Raman spectra on the surface outside the pits on the specimens exposed for 7, 10 and 15 days showed steady growth of the peak corresponding to Cr 3+ ions. This implied steady enrichment of Cr on the surface of the specimen which accounted for the gradual passivation with increased exposure time. (author)

  10. Electrochemical noise measurements of steel corrosion in the molten NaCl-K2SO4 system

    DEFF Research Database (Denmark)

    Cappeln, Frederik Vilhelm; Bjerrum, Niels; Petrushina, Irina

    2005-01-01

    -called active corrosion (i.e., the corrosion proceeds with no passivation due to the influence of chlorine), characterized by the formation of volatile metal chlorides as a primary corrosion product. It was found possible to obtain an empirical separation of general and intergranular corrosion using kurtosis (a......Electrochemical noise measurements have been carried out on AISI347, 10CrMo910, 15Mo3, and X20CrMoV121 steels in molten NaCl-K2SO4 at 630 degrees C. Different types of current noise have been identified for pitting, intergranular and peeling corrosion. The corrosion mechanism was the so...... statistical parameter calculated from the electrochemical noise data). It was found that average kurtosis values above 6 indicated intergranular corrosion and average values below 6 indicated general corrosion. The response time for localized corrosion detection in in-plant monitoring was approximately 90 min...

  11. Surveillance of instruments by noise analysis

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Random fluctuations of neutron flux, temperature, and pressure in a reactor provide multifrequency excitation of the corresponding instrumentation chains. Mathematical descriptors suitable for characterizing the output, or noise, of the instrumentation are reviewed with a view toward using such noise in detecting instrument faults. Demonstrations of the feasibility of this approach in a number of reactors provide illustrative examples. Comparisons with traditional surveillance testing are made, and a number of advantages and some disadvantages of using noise analysis as a supplementary technique are pointed out

  12. Deaf Smith County noise analysis: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    An analysis of activities proposed for the three major phases of development of the proposed nuclear waste repository site in Deaf Smith County, Texas, was conducted to quantify the noise levels and the effect of noise resulting from these activities. The report provides additional details of the predictive noise level modeling conducted for the site characterization, repository construction, and repository operation phases. Equivalent day/night sound levels are presented for each phase as sound level contours. Sound levels from onsite and offsite activities are addressed including traffic on access routes, and railroad construction and operation. A description of the predictive models, the analysis methodologies, the noise source inventories, the model outputs, and the evaluation criteria are included. 35 refs., 6 figs., 2 tabs

  13. Statistical analysis of brake squeal noise

    Science.gov (United States)

    Oberst, S.; Lai, J. C. S.

    2011-06-01

    Despite substantial research efforts applied to the prediction of brake squeal noise since the early 20th century, the mechanisms behind its generation are still not fully understood. Squealing brakes are of significant concern to the automobile industry, mainly because of the costs associated with warranty claims. In order to remedy the problems inherent in designing quieter brakes and, therefore, to understand the mechanisms, a design of experiments study, using a noise dynamometer, was performed by a brake system manufacturer to determine the influence of geometrical parameters (namely, the number and location of slots) of brake pads on brake squeal noise. The experimental results were evaluated with a noise index and ranked for warm and cold brake stops. These data are analysed here using statistical descriptors based on population distributions, and a correlation analysis, to gain greater insight into the functional dependency between the time-averaged friction coefficient as the input and the peak sound pressure level data as the output quantity. The correlation analysis between the time-averaged friction coefficient and peak sound pressure data is performed by applying a semblance analysis and a joint recurrence quantification analysis. Linear measures are compared with complexity measures (nonlinear) based on statistics from the underlying joint recurrence plots. Results show that linear measures cannot be used to rank the noise performance of the four test pad configurations. On the other hand, the ranking of the noise performance of the test pad configurations based on the noise index agrees with that based on nonlinear measures: the higher the nonlinearity between the time-averaged friction coefficient and peak sound pressure, the worse the squeal. These results highlight the nonlinear character of brake squeal and indicate the potential of using nonlinear statistical analysis tools to analyse disc brake squeal.

  14. Electrochemical noise evaluation of anodized aluminum. Comparative study against corrosion behaviour in the atmosphere

    Directory of Open Access Journals (Sweden)

    Betancourt, N.

    2003-12-01

    Full Text Available The present work reports the evaluation of aluminum and anodized aluminum by electrochemical noise, as a part of the PATINA/CYTED project of the working group Nº 5. A visual examination is also made. The samples were exposed at several Ibero-American atmospheres up to 2 years of exposure. Different thickness of anodized aluminum were evaluated. The electrochemical potential noise of the 5 μm unexposed sample (pattern showed a different behaviour to that showed by the other anodized specimens. This could be due to a slower sealed of the samples of higher thickness. The same behaviour was observed on the samples exposed at the rural station El Pardo. According to the visual examination, the samples of bare aluminum and those of anodized 5 μm thickness were the most affected by pitting corrosion in the highly polluted atmospheres. A good correlation between corrosion behaviour determined by visual examination and EN was obtained.

    Como parte de las investigaciones de la Red PATINA el grupo de trabajo Nº 5 dedicó su atención al comportamiento del aluminio desnudo y anodizado con diferentes espesores en diferentes atmósferas de Iberoamérica. En el presente trabajo se presenta una evaluación de patrones de aluminio 99,5 % de pureza desnudo y anodizado con espesores de 15 y 25 μm, mediante ruido electroquímico. Los resultados obtenidos se comparan con el comportamiento determinado en diferentes atmósferas durante un período de 2 años. El ruido de voltaje del patrón de 5 μm de espesor presenta un comportamiento diferente al de los restantes espesores, lo que coincide con una mayor susceptibilidad a la corrosión picadura de este primer anodizado. Se reportan también algunas diferencias en el ruido de corriente. Se concluye que mediante la utilización del ruido electroquímico es posible caracterizar el aluminio con respecto a su sensibilidad a la corrosión picadura en condiciones atmosféricas.

  15. Correlation of Process Data and Electrochemical Noise to Assess Kraft Digester Corrosion: Kamloops Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, SJ

    2002-05-09

    Electrochemical noise (ECN) probes were deployed in a carbon steel continuous kraft digester at five locations roughly equi-spaced from top to bottom of the vessel. Current and potential noise, the temperature at each probe location, and the value of about 60 process parameters (flow rates, liquor chemistry, etc.) were monitored continuously for a period of one year. Historical vessel inspection data, including inspections accomplished immediately prior to and immediately following probe deployment, and post-test evaluation of the probe components were used to assess/compare corrosion indications from the probes with physical changes in wall thickness and corrosion patterns on the digester shell. The results indicate that furnish composition is a significant variable influencing digester corrosion, with increasing amounts of Douglas fir in the nominal furnish correlating directly with increased corrosion activity on the ECN probes. All five probes detected changes in furnish composition approximately simultaneously, indicating rapid chemical communication through the liquor, but the effect was strongest and persisted longest relatively high in the digester. The ECN probes also indicate significant corrosion activity occurred at each probe position during shutdown/restart transients. Little or no correlation between ECN probe corrosion activity and other operational variables was observed. Post-test evaluation of the probes confirmed general corrosion of a magnitude that closely agreed with corrosion current sums calculated for each probe over the exposure period and with historical average corrosion rates for the respective locations. Further, no pitting was observed on any of the electrodes, which is consistent with the ECN data, relevant polarization curves developed for steel in liquor removed from the digester, and the post-test inspection of the digester.

  16. Corrosion initiation of stainless steel in HCl solution studied using electrochemical noise and in-situ atomic force microscope

    International Nuclear Information System (INIS)

    Li Yan; Hu Ronggang; Wang Jingrun; Huang Yongxia; Lin Changjian

    2009-01-01

    An in-situ atomic force microscope (AFM), optical microscope and electrochemical noise (ECN) techniques were applied to the investigation of corrosion initiations in an early stage of 1Cr18Ni9Ti stainless steel immersed in 0.5 M HCl solution. The electrochemical current noise data has been analyzed using discrete wavelet transform (DWT). For the first time, the origin of wavelet coefficients is discussed based on the correlation between the evolution of the energy distribution plot (EDP) of wavelet coefficients and topographic changes. It is found that the occurrence of initiation of metastable pitting at susceptive sites is resulted from the reductive breakdown of passive film of stainless steel in the diluted HCL solution. The coefficients d 4 -d 6 are originated from metastable pitting, d 7 represents the formation and growth of stable pitting while d 8 corresponds to the general corrosion.

  17. Study crevice corrosion alloys C-22 and 625 by electrochemical noise

    International Nuclear Information System (INIS)

    Ungaro, María L.; Carranza, Ricardo M.; Rodríguez, Martín A.

    2013-01-01

    C-22 and 625 alloys are two of the Ni –Cr-Mo alloys considered as candidate materials to form the corrosion resistance engineered barriers for nuclear waste repositories. The corrosion resistance of these alloys is remarkable in a wide variety of environments. Despite of their resistance these alloys are susceptible to crevice corrosion in a certain aggressive environments. This work presents the use of electrochemical noise technique to study crevice corrosion susceptibility of alloys C-22 and 625 in 1M NaCl acidic solutions at 60ºC and 90ºC. Asymmetrical electrodes and a complementary platinum electrode were used to assess the influence of cathodic reaction in crevice process. The obtained records were analyzed directly and through statistical parameters. The potential drop and the simultaneous increment of the current records indicated the occurrence of crevice corrosion. The alternative use of a platinum electrode resulted in higher currents and higher potentials and reduced the induction time to crevice formation. The reason for this behavior is that platinum surface allows faster cathodic reactions than C-22 and 625 alloys. The standard deviation of the current records was responsive to the crevice corrosion intensity. C-22 alloy had better crevice corrosion performance than 625 alloy. (author)

  18. Integrating neural network technology and noise analysis

    International Nuclear Information System (INIS)

    Uhrig, R.E.; Oak Ridge National Lab., TN

    1995-01-01

    The integrated use of neural network and noise analysis technologies offers advantages not available by the use of either technology alone. The application of neural network technology to noise analysis offers an opportunity to expand the scope of problems where noise analysis is useful and unique ways in which the integration of these technologies can be used productively. The two-sensor technique, in which the responses of two sensors to an unknown driving source are related, is used to demonstration such integration. The relationship between power spectral densities (PSDs) of accelerometer signals is derived theoretically using noise analysis to demonstrate its uniqueness. This relationship is modeled from experimental data using a neural network when the system is working properly, and the actual PSD of one sensor is compared with the PSD of that sensor predicted by the neural network using the PSD of the other sensor as an input. A significant deviation between the actual and predicted PSDs indicate that system is changing (i.e., failing). Experiments carried out on check values and bearings illustrate the usefulness of the methodology developed. (Author)

  19. Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

    Science.gov (United States)

    Yu, Xiao-Ying; Liu, Bingwen; Yang, Li; Zhu, Zihua; Marshall, Matthew J.

    2016-03-01

    A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

  20. Measurement of electrochemical noise for the study of corrosion processes of metallic alloys; Medida de ruido electroquimico para el estudio de rocesoso de corrosion de aleaciones metalicas

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Amaya, J. M.; Bethencourt, M.; Gonzalez-Rovira, L.; Botana, F. J.

    2009-07-01

    Electrochemical noise (EN) is a technique that allows the estimation of both the rate and the corrosion mechanism of different metallic alloys by means of the measurement and the analysis of the fluctuations of current and voltage. Its main advantage against other electrochemical techniques is that during the measurement process, the corrosive systems under study are not instrumentally disturbed, and therefore, the systems are kept at their natural corrosion potential. Two steps are necessary to use this technique: measurement and analysis of the EN signals. In this paper, the most important concepts related only to the measurement of EN are revised. The parameters most employed in the literature to analyse the EN signals will be described in another paper. In the present article, the experimental devices normally used to measure EN signals are firstly analysed. Subsequently, the most important properties of the EN signals are studied. Finally, the external sources of instrumental noise that can affect to the EN signals are described. (Author) 65 refs.

  1. Electrochemical noise and impedance of Au electrode/electrolyte interfaces enabling extracellular detection of glioma cell populations.

    Science.gov (United States)

    Rocha, Paulo R F; Schlett, Paul; Kintzel, Ulrike; Mailänder, Volker; Vandamme, Lode K J; Zeck, Gunther; Gomes, Henrique L; Biscarini, Fabio; de Leeuw, Dago M

    2016-10-06

    Microelectrode arrays (MEA) record extracellular local field potentials of cells adhered to the electrodes. A disadvantage is the limited signal-to-noise ratio. The state-of-the-art background noise level is about 10 μVpp. Furthermore, in MEAs low frequency events are filtered out. Here, we quantitatively analyze Au electrode/electrolyte interfaces with impedance spectroscopy and noise measurements. The equivalent circuit is the charge transfer resistance in parallel with a constant phase element that describes the double layer capacitance, in series with a spreading resistance. This equivalent circuit leads to a Maxwell-Wagner relaxation frequency, the value of which is determined as a function of electrode area and molarity of an aqueous KCl electrolyte solution. The electrochemical voltage and current noise is measured as a function of electrode area and frequency and follow unambiguously from the measured impedance. By using large area electrodes the noise floor can be as low as 0.3 μVpp. The resulting high sensitivity is demonstrated by the extracellular detection of C6 glioma cell populations. Their minute electrical activity can be clearly detected at a frequency below about 10 Hz, which shows that the methodology can be used to monitor slow cooperative biological signals in cell populations.

  2. Noise Analysis studies with neural networks

    International Nuclear Information System (INIS)

    Seker, S.; Ciftcioglu, O.

    1996-01-01

    Noise analysis studies with neural network are aimed. Stochastic signals at the input of the network are used to obtain an algorithmic multivariate stochastic signal modeling. To this end, lattice modeling of a stochastic signal is performed to obtain backward residual noise sources which are uncorrelated among themselves. There are applied together with an additional input to the network to obtain an algorithmic model which is used for signal detection for early failure in plant monitoring. The additional input provides the information to the network to minimize the difference between the signal and the network's one-step-ahead prediction. A stochastic algorithm is used for training where the errors reflecting the measurement error during the training are also modelled so that fast and consistent convergence of network's weights is obtained. The lattice structure coupled to neural network investigated with measured signals from an actual power plant. (authors)

  3. In situ synthesis, electrochemical and quantum chemical analysis of an amino acid-derived ionic liquid inhibitor for corrosion protection of mild steel in 1M HCl solution

    International Nuclear Information System (INIS)

    Kowsari, E.; Arman, S.Y.; Shahini, M.H.; Zandi, H.; Ehsani, A.; Naderi, R.; PourghasemiHanza, A.; Mehdipour, M.

    2016-01-01

    Highlights: • Electrochemical analysis of effectiveness of an amino acid-derived ionic liquid inhibitor. • Quantum chemical analysis of effectiveness of an amino acid-derived ionic liquid inhibitor. • Finding correlation between electrochemical analysis and quantum chemical analysis. - Abstract: In this study, an amino acid-derived ionic liquid inhibitor, namely tetra-n-butyl ammonium methioninate, was synthesized and the role this inhibitor for corrosion protection of mild steel exposed to 1.0 M HCl was investigated using electrochemical, quantum and surface analysis. By taking advantage of potentiodynamic polarization, the inhibitory action of tetra-n-butyl ammonium methioninate was found to be mainly mixed-type with dominant anodic inhibition. The effectiveness of the inhibitor was also indicated using electrochemical impedance spectroscopy (EIS). Moreover, to provide further insight into the mechanism of inhibition, electrochemical noise (EN) and quantum chemical calculations of the inhibitor were performed.

  4. Applications of noise analysis to nuclear safety

    International Nuclear Information System (INIS)

    Aguilar Martinez, Omar

    2000-01-01

    Noise Analysis techniques (analysis of the fluctuation of physical parameters) have been successfully applied to the operational vigilance of the technical equipment that plays a decisive role in the production cycle of a very complex industry. Although fluctuation measurements in nuclear installations started almost at the start of the nuclear era (see works by Feynman and Rossi on the development of neutron methodology), only recently have neutron noise diagnostic applications begun to be a part of the standard procedures for the performance of some modern nuclear installations. Following the relevant technical advances made in information sciences and analogical electronics, measuring the fluctuation of physical parameters has become a very effective tool for detecting, guarding and following up possible defects in a nuclear system. As the processing techniques for the fluctuation of a nuclear reactor's physical-neutron parameters have evolved (temporal and frequency analysis, multi-parameter self -regression analysis, etc.), the applications of the theory of non-lineal dynamics and chaos theory have progressed by focusing on the problem from another perspective. This work reports on those nuclear applications of noise analysis that increase nuclear safety in all types of nuclear facilities and that have been carried out by the author over the last decade, such as: -Void Force Critical Set Applications (Zero Power Reactor Applications, Central Institute of Physical Research, Budapest, Hungary); -Research Reactor Applications (Triga Mark III Reactor, National Institute of Nuclear Research, ININ, Mexico); -Power Reactor Applications in a Nuclear Power Plant (First Circuit of Block II, Paks Nuclear Center, Hungary); -Second Loop applications in a Nuclear Power Plant (Block I Paks Nuclear Center, Hungary; Block II Kalinin Nuclear Center, Russia); -Shield System Applications for the Transport of Radioisotopes (Nuclear Technology Center, Havana, Cuba) New trends in

  5. Corrosion resistance test based on electrochemical noise-limiting the number of long-lasting and costly climate chamber tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Veldman, D.; Gouwen, R.J.; Bende, E.E.; Eerenstein, W.

    2013-10-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. The electrochemical noise (EcN) set-up is a fast, direct corrosion measurement of solar cells, whereby results can be obtained within one hour. EcN measurements are presented for several solar cell concepts and different environments. It correlates with damp-heat degradation involving corrosion, which is rather common in EVA-encapsulated crystalline Si modules. Furthermore, the EcN test can be done as an evaluation tool when probing alternative brands, formulations or processing for metallisation pastes and as a screening test for new batches of metallisation paste.

  6. The Analysis of Low Noise Protection Barriers Influence on Tram Traffic Noise Levels

    Directory of Open Access Journals (Sweden)

    Ahac Maja

    2013-07-01

    Full Text Available The paper describes the analysis of tram traffic noise situation in residential areas in the vicinity of Drzic Avenue, one of the major routes between the northern and southern part of the Croatian capital city Zagreb, and the effect of low barriers placed by the tracks on tram noise mitigation. In order to evaluate the effect of planned protection measure, noise models were produced and verified with short-term field measurements. Calculations were conducted by means of noise prediction software, using European interim noise prediction method and 3D model of analyzed area. Finally, the results of noise calculations for existing tram traffic situation and planned measure of protection are presented on noise maps.

  7. NoiseMap and AEDT Gap Analysis

    Science.gov (United States)

    2017-09-30

    NoiseMap and the Aviation Environmental Design Tool (AEDT) both use an integrated modeling approach to calculate aircraft noise in and around an airfield. Both models also employ the same general overall approach by using airfield operational data, s...

  8. Noise analysis of switched integrator preamplifiers

    International Nuclear Information System (INIS)

    Sun Hongbo; Li Yulan; Zhu Weibin

    2004-01-01

    The main noise sources of switched integrator preamplifiers are discussed, and their noise performance are given combined PSpice simulation and experiments on them. Then, some practical methods on how to reduce noise of preamplifiers in two different integrator modes are provided. (authors)

  9. Analysis of sharpness increase by image noise

    Science.gov (United States)

    Kurihara, Takehito; Aoki, Naokazu; Kobayashi, Hiroyuki

    2009-02-01

    Motivated by the reported increase in sharpness by image noise, we investigated how noise affects sharpness perception. We first used natural images of tree bark with different amounts of noise to see whether noise enhances sharpness. Although the result showed sharpness decreased as noise amount increased, some observers seemed to perceive more sharpness with increasing noise, while the others did not. We next used 1D and 2D uni-frequency patterns as stimuli in an attempt to reduce such variability in the judgment. The result showed, for higher frequency stimuli, sharpness decreased as the noise amount increased, while sharpness of the lower frequency stimuli increased at a certain noise level. From this result, we thought image noise might reduce sharpness at edges, but be able to improve sharpness of lower frequency component or texture in image. To prove this prediction, we experimented again with the natural image used in the first experiment. Stimuli were made by applying noise separately to edge or to texture part of the image. The result showed noise, when added to edge region, only decreased sharpness, whereas when added to texture, could improve sharpness. We think it is the interaction between noise and texture that sharpens image.

  10. Noise Analysis of Switched-Current Circuits

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger; Bogason, Gudmundur

    1999-01-01

    The understanding of noise in analog sampled data systems is vital for the design of high resolution circuitry in the discrete time domain. In this paper a general description of sampled and held noise is presened. The noise calculations are verified by measurements on an analog delay line implem...

  11. Noise Analysis of Switched-Current Circuits

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger; Bogason, Gudmundur

    1998-01-01

    The understanding of noise in analog sampled data systems is vital for the design of high resolution circuitry. In this paper a general description of sampled and held noise is presented. The noise calculations are verified by measurements on an analog delay line implemented using switched...

  12. OPTIMAL AUTOMOBILE MUFFLER VIBRATION AND NOISE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Sujit Kumar Jha

    2013-06-01

    Full Text Available The muffler is the main part of the Automobile Exhaust System, consisting of fibrous and porous materials to absorb noise and vibrations. The exhaust gas mass coming from the engine can produce resonance, which may be the source of fatigue failure in the exhaust pipe due to the presence of continuous resonance. The modes on the muffler should be located away from the engine’s operating frequencies in order to minimise the resonance. The objective of this paper is to determine the frequencies that appear at the modes, which have the more adverse effect during the operation of the automobile. An impact test has been conducted by applying the force using a hard head hammer, and data generated have been used for plotting a graph of the transfer functions using MATLAB. Six points have been selected, namely 1, 2, 3, 4, 7, and 11 on the muffler for the impact test. The collected data from theses six points have been analysed for the addition of damping. Results suggests that increasing the mass increases the damping and lowers the modes of the transfer function. Further research will identify higher strength materials that can withstand the higher gas temperatures as well as the corrosion and erosion by the gas emitted from the engine. muffler, noise, vibration,modal analysis,

  13. Environmental analysis by electrochemical sensors and biosensors fundamentals

    CERN Document Server

    Moretto, Ligia Maria

    2014-01-01

    This book presents an exhaustive overview of electrochemical sensors and biosensors for the analysis and monitoring of the most important analytes in the environmental field, in industry, in treatment plants and in environmental research. The chapters give the reader a comprehensive, state-of-the-art picture of the field of electrochemical sensors suitable to environmental analytes, from the theoretical principles of their design to their implementation, realization and application. The first three chapters discuss fundamentals, and the last three chapters cover the main groups of analytes of environmental interest.

  14. Noise analysis for CCD-based ultraviolet and visible spectrophotometry.

    Science.gov (United States)

    Davenport, John J; Hodgkinson, Jane; Saffell, John R; Tatam, Ralph P

    2015-09-20

    We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4)  AU for the AvaSpec-3648 and 5.6×10(-4)  AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.

  15. Dynamical analysis of electrochemical wall shear rate measurements

    NARCIS (Netherlands)

    Steenhoven, van A.A.; Beucken, van den F.J.H.M.

    1991-01-01

    The performance of a circular electrochemical wall shear rate probe under unsteady flow conditions is analysed through a combined ezxperimental, numerical and analytical approach. The experiments are performed with a ferri- and ferrocyanide redox couple and compared to finite element analysis of the

  16. Analysis of broadband aerodynamic noise from VS45

    Energy Technology Data Exchange (ETDEWEB)

    Dundabin, P. [Renewable Energy Systems Ltd., Glasgow, Scotland (United Kingdom)

    1997-12-31

    This paper describes the analysis of acoustic data taken from the VS45 at Kaiser-Wilhelm-Koog. The aim was to investigate the dependence of aerodynamic noise on tip speed and angle of attack. In particular, the dependence of noise in individual third octave bands on these variable is examined. The analysis is divided into 3 sections: data selection, data checks and analysis of broadband nacelle noise; analysis of broadband aerodynamic noise and its sensitivity to tip speed and angle of attack. (LN)

  17. Interior noise analysis of a construction equipment cabin based on airborne and structure-borne noise predictions

    International Nuclear Information System (INIS)

    Kim, Sung Hee; Hong, Suk Yoon; Song, Jee Hun; Joo, Won Ho

    2012-01-01

    Noise from construction equipment affects not only surrounding residents, but also the operators of the machines. Noise that affects drivers must be evaluated during the preliminary design stage. This paper suggests an interior noise analysis procedure for construction equipment cabins. The analysis procedure, which can be used in the preliminary design stage, was investigated for airborne and structure borne noise. The total interior noise of a cabin was predicted from the airborne noise analysis and structure-borne noise analysis. The analysis procedure consists of four steps: modeling, vibration analysis, acoustic analysis and total interior noise analysis. A mesh model of a cabin for numerical analysis was made at the modeling step. At the vibration analysis step, the mesh model was verified and modal analysis and frequency response analysis are performed. At the acoustic analysis step, the vibration results from the vibration analysis step were used as initial values for radiated noise analysis and noise reduction analysis. Finally, the total cabin interior noise was predicted using the acoustic results from the acoustic analysis step. Each step was applied to a cabin of a middle-sized excavator and verified by comparison with measured data. The cabin interior noise of a middle-sized wheel loader and a large-sized forklift were predicted using the analysis procedure of the four steps and were compared with measured data. The interior noise analysis procedure of construction equipment cabins is expected to be used during the preliminary design stage

  18. Interior noise analysis of a construction equipment cabin based on airborne and structure-borne noise predictions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hee; Hong, Suk Yoon [Seoul National University, Seoul (Korea, Republic of); Song, Jee Hun [Chonnam National University, Gwangju (Korea, Republic of); Joo, Won Ho [Hyundai Heavy Industries Co. Ltd, Ulsan (Korea, Republic of)

    2012-04-15

    Noise from construction equipment affects not only surrounding residents, but also the operators of the machines. Noise that affects drivers must be evaluated during the preliminary design stage. This paper suggests an interior noise analysis procedure for construction equipment cabins. The analysis procedure, which can be used in the preliminary design stage, was investigated for airborne and structure borne noise. The total interior noise of a cabin was predicted from the airborne noise analysis and structure-borne noise analysis. The analysis procedure consists of four steps: modeling, vibration analysis, acoustic analysis and total interior noise analysis. A mesh model of a cabin for numerical analysis was made at the modeling step. At the vibration analysis step, the mesh model was verified and modal analysis and frequency response analysis are performed. At the acoustic analysis step, the vibration results from the vibration analysis step were used as initial values for radiated noise analysis and noise reduction analysis. Finally, the total cabin interior noise was predicted using the acoustic results from the acoustic analysis step. Each step was applied to a cabin of a middle-sized excavator and verified by comparison with measured data. The cabin interior noise of a middle-sized wheel loader and a large-sized forklift were predicted using the analysis procedure of the four steps and were compared with measured data. The interior noise analysis procedure of construction equipment cabins is expected to be used during the preliminary design stage.

  19. Noise

    Science.gov (United States)

    Noise is all around you, from televisions and radios to lawn mowers and washing machines. Normally, you ... sensitive structures of the inner ear and cause noise-induced hearing loss. More than 30 million Americans ...

  20. Timing Noise Analysis of NANOGrav Pulsars

    OpenAIRE

    Perrodin, Delphine; Jenet, Fredrick; Lommen, Andrea; Finn, Lee; Demorest, Paul; Ferdman, Robert; Gonzalez, Marjorie; Nice, David; Ransom, Scott; Stairs, Ingrid

    2013-01-01

    We analyze timing noise from five years of Arecibo and Green Bank observations of the seventeen millisecond pulsars of the North-American Nanohertz Observatory for Gravitational Waves (NANOGrav) pulsar timing array. The weighted autocovariance of the timing residuals was computed for each pulsar and compared against two possible models for the underlying noise process. The first model includes red noise and predicts the autocovariance to be a decaying exponential as a function of time lag. Th...

  1. Analysis of noise emitted from diesel engines

    Science.gov (United States)

    Narayan, S.

    2015-12-01

    In this work combustion noise produced in diesel engines has been investigated. In order to reduce the exhaust emissions various injection parameters need to be studied and optimized. The noise has been investigated by mean of data obtained from cylinder pressure measurements using piezo electric transducers and microphones on a dual cylinder diesel engine test rig. The engine was run under various operating conditions varying various injection parameters to investigate the effects of noise emissions under various testing conditions.

  2. Orbiter CCTV video signal noise analysis

    Science.gov (United States)

    Lawton, R. M.; Blanke, L. R.; Pannett, R. F.

    1977-01-01

    The amount of steady state and transient noise which will couple to orbiter CCTV video signal wiring is predicted. The primary emphasis is on the interim system, however, some predictions are made concerning the operational system wiring in the cabin area. Noise sources considered are RF fields from on board transmitters, precipitation static, induced lightning currents, and induced noise from adjacent wiring. The most significant source is noise coupled to video circuits from associated circuits in common connectors. Video signal crosstalk is the primary cause of steady state interference, and mechanically switched control functions cause the largest induced transients.

  3. The influence of the cathodic process on the interpretation of electrochemical noise signals arising from pitting corrosion of stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, Helmuth Sarmiento [Federal Institute for Materials Research and Testing, Unter den Eichen 87, 12205 Berlin (Germany)], E-mail: Helmuth.sarmiento-klapper@bam.de; Goellner, Joachim [Otto von Guericke University Magdeburg, P.O. Box 4120, Magdeburg (Germany); Heyn, Andreas [Federal Institute for Materials Research and Testing, Unter den Eichen 87, 12205 Berlin (Germany); Otto von Guericke University Magdeburg, P.O. Box 4120, Magdeburg (Germany)

    2010-04-15

    The use of electrochemical noise (EN) measurements for the investigation and monitoring of corrosion has allowed many interesting advances in the corrosion science in recent years. A special advantage of EN measurements includes the possibility to detect and study the early stages of localized corrosion. Nevertheless, the understanding of the electrochemical information included in the EN signal is actually very limited. The role of the cathodic process on the EN signals remains uncertain and has not been sufficiently investigated to date. Thus, an accurate understanding of the influence of the cathodic process on the EN signal is still lacking. On the basis of different kinetics of the oxygen reduction it was established that the anodic amplitude of transients arising from pitting corrosion on stainless steel can be decreased by the corresponding electron consumption of the cathodic process. Therefore, the stronger the electron consumption, the weaker the anodic amplitude of the EN signal becomes. EN signals arising from pitting corrosion on stainless steel can be measured because the cathodic process is inhibited by the passive layer. This was confirmed by means of EN measurements under cathodic polarisation. Since the cathodic process plays a decisive role on the form of transients arising from pitting corrosion, its influence must be considered in the evaluation and interpretation of the EN signals.

  4. Analysis of landing gear noise during approach

    NARCIS (Netherlands)

    Merino Martinez, R.; Snellen, M.; Simons, D.G.

    2016-01-01

    Airframe noise is becoming increasingly important during approach, even reaching higher noise levels than the engines in some cases. More people are a_ected due to low ight altitudes and _xed tra_c routing associated with typical approaches. For most air- craft types, the landing gear system is a

  5. Davis Canyon noise analysis: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    A study was performed as part of the Civilian Radioactive Waste Management Program to quantify the level and effect of noise from the various major phases of development of the proposed potentially acceptable nuclear waste repository site at Davis Canyon, Utah. This report contains the results of a predictive noise level study for the site characterization, repository construction, and repository operational phases. Included herein are graphic representations of energy averaged sound levels, and of audibility levels representing impact zones expected during each phase. Sound levels from onsite and offsite activity including traffic on highways and railroad routes are presented in isopleth maps. A description of the Environmental Noise Prediction Model used for the study, the study basis and methodologies, and actual modeling data are provided. Noise and vibration levels from blasting are also predicted and evaluated. Protective noise criteria containing a margin of safety are used in relation to residences, schools, churches, noise-sensitive recreation areas, and noise-sensitive biological resources. Protective ground motion criteria for ruins and delicate rock formation in Canyonlands National Park and for human annoyance are used in the evaluation of blasting. The evaluations provide the basis for assessing the noise impacts from the related activities at the proposed repository. 45 refs., 21 figs., 15 tabs

  6. Electrochemical Random Signal Analysis during Localized Corrosion of Anodized 1100 Aluminum Alloy in Chloride Environments

    International Nuclear Information System (INIS)

    Sakairi, M.; Shimoyama, Y.; Nagasawa, D.

    2008-01-01

    A new type of electrochemical random signal (electrochemical noise) analysis technique was applied to localized corrosion of anodic oxide film formed 1100 aluminum alloy in 0.5 kmol/m 3 H 3 BO 4 /0.05 kmol/m 3 Na 2 B 4 O 7 with 0.01 kmol/m 3 NaCl. The effect of anodic oxide film structure, barrier type, porous type, and composite type on galvanic corrosion resistance was also examined. Before localized corrosion started, incubation period for pitting corrosion, both current and potential slightly change as initial value with time. The incubation period of porous type anodic oxide specimens are longer than that of barrier type anodic oxide specimens. While pitting corrosion, the current and potential were changed with fluctuations and the potential and the current fluctuations show a good correlation. The records of the current and potential were processed by calculating the power spectrum density (PSD) by the Fast Fourier Transform (FFT) method. The potential and current PSD decrease with increasing frequency, and the slopes are steeper than or equal to minus one (-1). This technique allows observation of electrochemical impedance changes during localized corrosion

  7. Analysis of noise lines in the Virgo C7 data

    International Nuclear Information System (INIS)

    Acernese, F; Amico, P; Alshourbagy, M

    2007-01-01

    The paper presents a description of the work of detection and identification of frequency lines in the Virgo dark fringe data from run C7. A number of methods are highlighted by which noise frequency lines are detected by data analysis and measurements in the laboratory. In this paper we give a description of the list of noise line candidates provided by the pulsar search analysis, the investigation of 10 Hz (and harmonics) noise, violin modes, noise from the end station buildings' air conditioners, sidebands in calibration lines and aliasing in the 4 kHz reconstructed data

  8. Analysis of noise lines in the Virgo C7 data

    Energy Technology Data Exchange (ETDEWEB)

    Acernese, F [INFN, Sezione di Napoli and/or Universita di Napoli ' Federico II' Complesso Universitario di Monte S Angelo, and/or Universita di Salerno, Fisciano (Italy); Amico, P [INFN, Sezione di Perugia and/or Universita di Perugia, Perugia (Italy); Alshourbagy, M [INFN, Sezione di Pisa and/or Universita di Pisa, Pisa (Italy)] (and others)

    2007-10-07

    The paper presents a description of the work of detection and identification of frequency lines in the Virgo dark fringe data from run C7. A number of methods are highlighted by which noise frequency lines are detected by data analysis and measurements in the laboratory. In this paper we give a description of the list of noise line candidates provided by the pulsar search analysis, the investigation of 10 Hz (and harmonics) noise, violin modes, noise from the end station buildings' air conditioners, sidebands in calibration lines and aliasing in the 4 kHz reconstructed data.

  9. TRANSITIONS IN ELECTROCHEMICAL NOISE DURING PITTING CORROSION OF ALUMINUM IN CHLORIDE ENVIRONMENTS

    International Nuclear Information System (INIS)

    SASAKI, K.; ISAACS, H.S.; LEVY, P.W.

    2001-01-01

    Aluminum, in a chloride containing solutions close to its pitting potential, shows vigorous fluctuations in current and potential. Measurements have been made of the freely corroding potential, and the currents between interconnected electrodes. It is shown that there is a transition in the behavior of the transients. The transition occurs when multiple active pits are present and electrochemical communication occurs between them. The major source of current and potential transients is the growth process in the active pits rather than meta-stable pitting at the passive surface

  10. TRANSITIONS IN ELECTROCHEMICAL NOISE DURING PITTING CORROSION OF ALUMINUM IN CHLORIDE ENVIRONMENTS.

    Energy Technology Data Exchange (ETDEWEB)

    SASAKI,K.; ISAACS,H.S.; LEVY,P.W.

    2001-09-02

    Aluminum, in a chloride containing solutions close to its pitting potential, shows vigorous fluctuations in current and potential. Measurements have been made of the freely corroding potential, and the currents between interconnected electrodes. It is shown that there is a transition in the behavior of the transients. The transition occurs when multiple active pits are present and electrochemical communication occurs between them. The major source of current and potential transients is the growth process in the active pits rather than meta-stable pitting at the passive surface.

  11. Automated pattern recognition system for noise analysis

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Piety, K.R.

    1980-01-01

    A pattern recognition system was developed at ORNL for on-line monitoring of noise signals from sensors in a nuclear power plant. The system continuousy measures the power spectral density (PSD) values of the signals and the statistical characteristics of the PSDs in unattended operation. Through statistical comparison of current with past PSDs (pattern recognition), the system detects changes in the noise signals. Because the noise signals contain information about the current operational condition of the plant, a change in these signals could indicate a change, either normal or abnormal, in the operational condition

  12. Period analysis at high noise level

    International Nuclear Information System (INIS)

    Kovacs, G.

    1980-01-01

    Analytical expressions are derived for the variances of some types of the periodograms due to normal-distributed noise present in the data. The equivalence of the Jurkevich and the Warner and Robinson methods is proved. The optimum phase cell number of the Warner and Robinson method is given; this number depends on the data length, signal form and noise level. The results are illustrated by numerical examples. (orig.)

  13. Richton Dome noise analysis: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    A study was performed as part of the Civilian Radioactive Waste Management Program to quantify the level and effect of noise from the various major phases of development of the proposed potentially acceptable nuclear waste repository site at Richton Dome, Mississippi. This report contains the results of a predictive noise level study for the site characterization, repository construction, and repository operational phases. Included herein are graphic representations of energy averaged day/night sound levels representing impact zones expected during each phase. Sound levels from onsite and offsite activity including traffic on highways and railroad routes are presented in isopleth maps. A description of the Environmental Noise Prediction Model used for the study, the study basis and methodologies, and actual modeling data are provided. Noise and vibration levels from blasting are also predicted and evaluated. Protective noise criteria containing a margin of safety are used for persons in relation to residences, schools, churches, and agricultural areas. Protective ground motion criteria for residential dwelling and for human annoyance are used in the evaluation. The evaluation provides the bases for assessing the noise impacts from the related activities at the proposed repository. 24 refs., 8 figs., 8 tabs

  14. Dynamical noise filter and conditional entropy analysis in chaos synchronization.

    Science.gov (United States)

    Wang, Jiao; Lai, C-H

    2006-06-01

    It is shown that, in a chaotic synchronization system whose driving signal is exposed to channel noise, the estimation of the drive system states can be greatly improved by applying the dynamical noise filtering to the response system states. If the noise is bounded in a certain range, the estimation errors, i.e., the difference between the filtered responding states and the driving states, can be made arbitrarily small. This property can be used in designing an alternative digital communication scheme. An analysis based on the conditional entropy justifies the application of dynamical noise filtering in generating quality synchronization.

  15. Neutron noise analysis for malfunction diagnosis at sodium cooled reactors

    International Nuclear Information System (INIS)

    Hoppe, P.

    1978-09-01

    For the investigation of the potential use of neutron noise analysis at sodium cooled power reactors, measurements have been performed at the KNK I reactor over a period of 18 month under different operational conditions. The signal fluctuations of the following tranducers have been recorded: In-core and Ex-core neutron detectors, temperature-, flow-, pressure-, vibration- and acoustic sensors. These extensive measurements have been analyzed in the frequency range from 0,001 Hz to 1000 Hz with all currently known methods for the identification of noise sources. The following results have been found: - Neutron noise for f 20 Hz the white detection noise prevails. In the region from 1 Hz to 20 Hz the vibrations of core components contribute to neutron noise. - Neutron noise is influenced by the state of the plant. - The contributions to neutron noise due to the fluctuations of coolant flow and inlet temperature are small compared to those produced by the movements of the control rod initiated by the reactor control system. The quantitatively unidentifiable amount of reactivity fluctuations (0,6 time-dependent thermal bowing of the core. With respect to these results and by calculation of the neutron noise patterns to be expected for the SNR 300, the following possible applications for neutron noise analysis have been found: By means of neutron noise analysis only reactivity fluctuations can be identified and supervised which are produced by time dependent changes of the core geometry. Furthermore neutron noise analysis is well suited for a sensitive detection of control rod vibrations and of local sodium boiling. Finally it can be used for the surveillance of the proper functioning of the reactor control system and of the control rod drive mechanism. (orig./HP) 891 HP [de

  16. RB reactor noise analysis; Analiza sumova reaktora RB

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, M; Velickovic, Lj; Markovic, V; Jovanovic, S [Institut za nuklearne nauke Boris Kidric, Vinca, Beograd (Yugoslavia)

    1964-07-01

    Statistical fluctuations of reactivity represent reactor noise. Analysis of reactor noise enables determining a series of reactor kinetic parameters. Fluctuations of power was measured by ionization chamber placed next to the tank of the RB reactor. The signal was digitized by an analog-digital converter. After calculation of the mean power, 3000 data obtained by sampling were analysed.

  17. Lable-free electrochemical analysis of biomacromolecules

    Czech Academy of Sciences Publication Activity Database

    Paleček, Emil; Dorčák, Vlastimil

    2017-01-01

    Roč. 9, č. 2017 (2017), s. 434-450 ISSN 2352-9407 R&D Projects: GA ČR(CZ) GA17-08971S; GA ČR(CZ) GA15-15479S Institutional support: RVO:68081707 Keywords : carbon-paste electrodes * pyrolytic-graphite electrode * structure-sensitive analysis Subject RIV: CG - Electrochemistry OBOR OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)

  18. Analysis of Subway Interior Noise at Peak Commuter Time.

    Science.gov (United States)

    Lee, Donguk; Kim, Gibbeum; Han, Woojae

    2017-07-01

    Although mass transit systems are convenient and efficient for urban people, little attention has been paid to the potential hearing hazard from their noise. The purpose of the current study was to measure and analyze levels of subway interior noise at peak commuter times and to provide information about commuters' daily dose of noise exposure. To measure the subway interior noise, nine subway lines inside Seoul (i.e., lines 1-9) and six lines surrounding the capital city area (i.e., Central, Bundang, Sinbundang, Incheon, Gyeongui, and Gyeongchun) were chosen. The noise was measured and recorded by a sound level meter for two-hour periods in the morning and evening. 1) In the LZeq analysis, the average noise level of all 15 lines was 72.78 dB; the maximum and minimum noise levels were 78.34 and 62.46 dB, respectively. The average noise level of the nine lines inside Seoul was 73.45 dB, which was 1.68-dB louder than that of the six lines surrounding the capital city area. 2) Based on the LZeq analysis of 33 measured frequencies, 12.5 Hz was the highest frequency and 20,000 Hz was the lowest. 3) There was no remarkable difference in the level of subway interior noise between morning and evening peak commuter times. We concluded that the level of subway interior noise was not loud enough for commuters to incur noise-induced hearing loss. Regardless, environmental noise control efforts in the subway system might be needed for commuters who take a subway every day.

  19. Reactor noise analysis applications in NPP I and C systems

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, O. [International Atomic Energy Agency, Wagramer Strosse 5, A-1400 Vienna, Austria Ontario Power Generation, 230 Westney Road South, Ajax, Ont. L1S 7R3 (Canada)

    2006-07-01

    Reactor noise analysis techniques are used in many NPPs on a routine basis as 'inspection tools' to get information on the dynamics of reactor processes and their instrumentation in a passive, non-intrusive way. The paper discusses some of the tasks and requirements an NPP has to take to implement and to use the full advantages of reactor noise analysis techniques. Typical signal noise analysis applications developed for the monitoring of the reactor shutdown system and control system instrumentation of the Candu units of Ontario Power Generation and Bruce Power are also presented. (authors)

  20. Digital signal processing for the Johnson noise thermometry: a time series analysis of the Johnson noise

    International Nuclear Information System (INIS)

    Moon, Byung Soo; Hwang, In Koo; Chung, Chong Eun; Kwon, Kee Choon; David, E. H.; Kisner, R.A.

    2004-06-01

    In this report, we first proved that a random signal obtained by taking the sum of a set of signal frequency signals generates a continuous Markov process. We used this random signal to simulate the Johnson noise and verified that the Johnson noise thermometry can be used to improve the measurements of the reactor coolant temperature within an accuracy of below 0.14%. Secondly, by using this random signal we determined the optimal sampling rate when the frequency band of the Johnson noise signal is given. Also the results of our examination on how good the linearity of the Johnson noise is and how large the relative error of the temperature could become when the temperature increases are described. Thirdly, the results of our analysis on a set of the Johnson noise signal blocks taken from a simple electric circuit are described. We showed that the properties of the continuous Markov process are satisfied even when some channel noises are present. Finally, we describe the algorithm we devised to handle the problem of the time lag in the long-term average or the moving average in a transient state. The algorithm is based on the Haar wavelet and is to estimate the transient temperature that has much smaller time delay. We have shown that the algorithm can track the transient temperature successfully

  1. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  2. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  3. PC analysis of stochastic differential equations driven by Wiener noise

    KAUST Repository

    Le Maitre, Olivier; Knio, Omar

    2015-01-01

    A polynomial chaos (PC) analysis with stochastic expansion coefficients is proposed for stochastic differential equations driven by additive or multiplicative Wiener noise. It is shown that for this setting, a Galerkin formalism naturally leads

  4. To the analysis of reactor noise in boiling water reactors

    International Nuclear Information System (INIS)

    Seifritz, W.

    1972-01-01

    The paper contains some basic thoughts on the problem of neutron flux oscillations in power reactors. The advantages of self-powered detectors and their function are explained. In addition, noise measurements of the boiling water reactors at Lingen and Holden are described, and the possibilities of an employment of vanadium detectors for the analysis of reactor noise are discussed. The final pages of the paper contain a complete list of the author's publications in the field of reactor noise analysis. (RW/AK) [de

  5. Application of autoregressive moving average model in reactor noise analysis

    International Nuclear Information System (INIS)

    Tran Dinh Tri

    1993-01-01

    The application of an autoregressive (AR) model to estimating noise measurements has achieved many successes in reactor noise analysis in the last ten years. The physical processes that take place in the nuclear reactor, however, are described by an autoregressive moving average (ARMA) model rather than by an AR model. Consequently more correct results could be obtained by applying the ARMA model instead of the AR model to reactor noise analysis. In this paper the system of the generalised Yule-Walker equations is derived from the equation of an ARMA model, then a method for its solution is given. Numerical results show the applications of the method proposed. (author)

  6. The Signal and Noise Analysis of Direct Conversion EHM Transceivers

    Directory of Open Access Journals (Sweden)

    Shayegh

    2006-01-01

    Full Text Available A direct conversion modulator-demodulator with even harmonic mixers with emphasis on noise analysis is presented. The circuits consist of even harmonic mixers (EHMs realized with antiparallel diode pairs (APDPs. We evaluate the different levels of I/Q imbalances and DC offsets and use signal space concepts to analyze the bit error rate (BER of the proposed transceiver using M-ary QAM schemes. Moreover, the simultaneous analysis of the signal and noise has been presented.

  7. Corrosion behaviour of zinc and aluminum magnesium alloys by scanning reference electrode technique (SRET) and electrochemical noise (EN)

    International Nuclear Information System (INIS)

    Klassen, R.D.; Roberge, P.R.; Lafront, A.-M.; Oteyaka, M.O.; Ghali, E.

    2005-01-01

    The corrosion characteristics of five permanent mould magnesium alloys were studied. Two contained aluminum (AZ91D and AZ91E) and three contained zinc as the primary alloying element (ZA104 (Zn 10%, Al 4%), ZAC and ZACS). ZAC contained a small amount of calcium and ZACS contained small amounts of calcium and strontium. Two techniques were used in this study, namely 1) scanning reference electrode technique (SRET) and 2) electrochemical noise (EN). The test solution for each case was 5% NaCl saturated with Mg(OH)2 at room temperature. According to the EN measurements, the corrosion rate of AZ91D was the lowest followed by AZ91E, ZACS, ZAC and ZA104. The EN measurements showed that both the frequency and magnitude of current transients were much higher for the zinc based alloys than for the aluminum based alloys. The SRET measurements illustrated that localized corrosion occurred more frequently on the ZA104 sample than on the AZ91D sample. It seemed that increasing the level of zinc and lowering the level of aluminum relative to the levels in AZ91D does not improve corrosion resistance. (author)

  8. A state of the art on electrochemical noise technique. Assessment of corrosion characteristics and development of remedial technology in nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jin; Kim, Joung Soo; Kim, Hong Pyo; Lim, Yun Soo; Yi, Yong Sun; Chung, Man Kyo

    2003-02-01

    The studies for the application of electrochemical noise technique were reviewed in terms of principle, analysing method and application examples of this technique. Because 4% of the economic damage of industry is caused by metallic corrosion, it is important to find and protect corrosive materials and location. By corrosion monitoring of industrial facilities such as nuclear power plant using Electrochemical Noise Measurement(ENM), corrosion attack can be detected and furthermore it can be indicated whether the attacked materials is replaced by new one or not. According to development of control and electronic technology, it was easy to apply ENM to the industry and the interest in ENM also increased. As corrosion is produced on a metal under corrosive environment, local anode(oxidation) and cathode(reduction) are formed. Hence, there is potential difference and current flow between the anode and cathode. ENM is monitoring the potential difference and the current flow with time by high impedance load voltmeter and Zero Resistance Ammeter(ZRA), respectively. The potential difference and current flow generated spontaneously without any application of current and potential between electrodes are monitored by electrochemical noise technique, Thereby ENM can be regarded as the most ideal corrosion monitoring method for the industrial facility and nuclear power plant having corrosion damage and difficulty in access of human body. Moreover, it is possible to obtain the spontaneous and reliable results from the metals damaged by ununiform and localized corrosion such as pitting and SCC using ENM while it is difficult to obtain the reliable result using traditional linear polarization and ac-impedance measurement. In many countries, there are extensive works concerned with application of electrochemical noise technique to corrosion monitoring of nuclear power plant and other industrial facilities, whereas there is little work on this field in Korea. Systematic study for

  9. Receive-Noise Analysis of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Bozkurt, Ayhan; Yaralioglu, G Goksenin

    2016-11-01

    This paper presents an analysis of thermal (Johnson) noise received from the radiation medium by otherwise noiseless capacitive micromachined ultrasonic transducer (CMUT) membranes operating in their fundamental resonance mode. Determination of thermal noise received by multiple numbers of transducers or a transducer array requires the assessment of cross-coupling through the radiation medium, as well as the self-radiation impedance of the individual transducer. We show that the total thermal noise received by the cells of a CMUT has insignificant correlation, and is independent of the radiation impedance, but is only determined by the mass of each membrane and the electromechanical transformer ratio. The proof is based on the analytical derivations for a simple transducer with two cells, and extended to transducers with numerous cells using circuit simulators. We used a first-order model, which incorporates the fundamental resonance of the CMUT. Noise power is calculated by integrating over the entire spectrum; hence, the presented figures are an upper bound for the noise. The presented analyses are valid for a transimpedance amplifier in the receive path. We use the analysis results to calculate the minimum detectable pressure of a CMUT. We also provide an analysis based on the experimental data to show that output noise power is limited by and comparable to the theoretical upper limit.

  10. Spectrogram Image Analysis of Error Signals for Minimizing Impulse Noise

    Directory of Open Access Journals (Sweden)

    Jeakwan Kim

    2016-01-01

    Full Text Available This paper presents the theoretical and experimental study on the spectrogram image analysis of error signals for minimizing the impulse input noises in the active suppression of noise. Impulse inputs of some specific wave patterns as primary noises to a one-dimensional duct with the length of 1800 mm are shown. The convergence speed of the adaptive feedforward algorithm based on the least mean square approach was controlled by a normalized step size which was incorporated into the algorithm. The variations of the step size govern the stability as well as the convergence speed. Because of this reason, a normalized step size is introduced as a new method for the control of impulse noise. The spectrogram images which indicate the degree of the attenuation of the impulse input noises are considered to represent the attenuation with the new method. The algorithm is extensively investigated in both simulation and real-time control experiment. It is demonstrated that the suggested algorithm worked with a nice stability and performance against impulse noises. The results in this study can be used for practical active noise control systems.

  11. Turbofan noise generation. Volume 1: Analysis

    Science.gov (United States)

    Ventres, C. S.; Theobald, M. A.; Mark, W. D.

    1982-01-01

    Computer programs were developed which calculate the in-duct acoustic modes excited by a fan/stator stae operating at subsonic tip speed. Three noise source mechanisms are included: (1) sound generated by the rotor blades interacting with turbulence ingested into, or generated within, the inlet duct; (2) sound generated by the stator vanes interacting with the turbulent wakes of the rotors blades; and (3) sound generated by the stator vanes interacting with the mean velocity deficit wakes of the rotor blades. The fan/stator stage is modeled as an ensemble of blades and vanes of zero camber and thickness enclosed within an infinite hard-walled annular duct. Turbulence drawn into or generated within the inlet duct is modeled as nonhomogeneous and anisotropic random fluid motion, superimposed upon a uniform axial mean flow, and convected with that flow. Equations for the duct mode amplitudes, or expected values of the amplitudes, are derived.

  12. Detection of localised corrosion by means of statistic and harmonic analysis of spontaneous potential noise

    International Nuclear Information System (INIS)

    Carassiti, F.; Cigna, R.; Goolamallee, R.; Gusmano, G.

    1989-01-01

    The analysis of the electrochemical noise, i.e. of the spontaneous fluctuations of potential of a freely corroding electrode, probably represent one of the most interesting novelty of the last years in the field of corrosion monitoring. Although this technique is still at an early stage, it could lead to interesting developments, especially for identifying localized forms of corrosion. The experiments which have been reported in the literature generally agree that in absence of active corrosion a slight variation of the potential is observed accompanied by non gaussian fluctuations; in presence of the onset of pitting a series of sharp variation is observed followed by relatively slow exponential recovery. In the domain of frequency the slope of the noise frequency curve is less than that noticed in the absence of active corrosion. In the domain of time generally the standard deviation of noise is proportional to the corrosion rate. Moreover it has been noticed that small variation in the experimental condition could cause modification in the shape of the spontaneous potential fluctuation and introduce some confusion in the analysis of data. Digital filtering of disturbs could allow a better reproducibility to be achieved. (author) 4 refs., 9 figs

  13. Study on statistical analysis of nonlinear and nonstationary reactor noises

    International Nuclear Information System (INIS)

    Hayashi, Koji

    1993-03-01

    For the purpose of identification of nonlinear mechanism and diagnosis of nuclear reactor systems, analysis methods for nonlinear reactor noise have been studied. By adding newly developed approximate response function to GMDH, a conventional nonlinear identification method, a useful method for nonlinear spectral analysis and identification of nonlinear mechanism has been established. Measurement experiment and analysis were performed on the reactor power oscillation observed in the NSRR installed at the JAERI and the cause of the instability was clarified. Furthermore, the analysis and data recording methods for nonstationary noise have been studied. By improving the time resolution of instantaneous autoregressive spectrum, a method for monitoring and diagnosis of operational status of nuclear reactor has been established. A preprocessing system for recording of nonstationary reactor noise was developed and its usability was demonstrated through a measurement experiment. (author) 139 refs

  14. Noise Pollution: Do We Need a Solution? An Analysis of Noise in a Cardiac Care Unit.

    Science.gov (United States)

    Ryan, Kevin M; Gagnon, Matthew; Hanna, Tyler; Mello, Brad; Fofana, Mustapha; Ciottone, Gregory; Molloy, Michael

    2016-08-01

    49.24% of alarms. The CCU cares for ill patients requiring constant monitoring. Despite advances in technology, measured noise levels for the hospital studied exceeded WHO standards of 40 dB and peaks of 45 dB, even during night hours when patients require rest. Further work is required to reduce noise levels and examine effects on patient satisfaction, clinical outcomes, and length of stay. Ryan KM , Gagnon M , Hanna T , Mello B , Fofana M , Ciottone G , Molloy M . Noise pollution: do we need a solution? An analysis of noise in a cardiac care unit. Prehosp Disaster Med. 2016;31(4):432-435.

  15. Noise, a tool for analysis of neutronic impact noise; Noise, Una herramienta para el analisis del impacto del ruido neutronico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Escobar, A.; Lopez Cedillo, A.; Ortego Inigo, A.; Ortega Pascual, F.

    2013-07-01

    The NOISE application is an off-line tool developed by TECNATOM for Trillo, which simulates the power calculation circuit protection system and L-RELEB system function limitation. It is fed with real data of neutron flux with a frequency of 100 Hz and is designed for predictive analysis system alarms limitation as a result of the oscillations of neutron flux measurements. Addition is to be used as a tool for engineering support to adjust the effective value of the dead band surround filters preventing possible system alarms cause impact on the operation.

  16. OPTIMAL AUTOMOBILE MUFFLER VIBRATION AND NOISE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Sujit Kumar Jha

    2013-06-01

    Full Text Available The muffler is the main part of the Automobile Exhaust System, consisting of fibrous and porous materials to absorb noise and vibrations. The exhaust gas mass coming from the engine can produce resonance, which may be the source of fatigue failure in the exhaust pipe due to the presence of continuous resonance. The modes on the muffler should be located away from the engine’s operating frequencies in order to minimise the resonance. The objective of this paper is to determine the frequencies that appear at the modes, which have the more adverse effect during the operation of the automobile. An impact test has been conducted by applying the force using a hard head hammer, and data generated have been used for plotting a graph of the transfer functions using MATLAB. Six points have been selected, namely 1, 2, 3, 4, 7, and 11 on the muffler for the impact test. The collected data from theses six points have been analysed for the addition of damping. Results suggests that increasing the mass increases the damping and lowers the modes of the transfer function. Further research will identify higher strength materials that can withstand the higher gas temperatures as well as the corrosion and erosion by the gas emitted from the engine.

  17. Quantitative analysis of LISA pathfinder test-mass noise

    International Nuclear Information System (INIS)

    Ferraioli, Luigi; Congedo, Giuseppe; Hueller, Mauro; Vitale, Stefano; Hewitson, Martin; Nofrarias, Miquel; Armano, Michele

    2011-01-01

    LISA Pathfinder (LPF) is a mission aiming to test the critical technology for the forthcoming space-based gravitational-wave detectors. The main scientific objective of the LPF mission is to demonstrate test masses free falling with residual accelerations below 3x10 -14 m s -2 /√(Hz) at 1 mHz. Reaching such an ambitious target will require a significant amount of system optimization and characterization, which will in turn require accurate and quantitative noise analysis procedures. In this paper, we discuss two main problems associated with the analysis of the data from LPF: i) excess noise detection and ii) noise parameter identification. The mission is focused on the low-frequency region ([0.1, 10] mHz) of the available signal spectrum. In such a region, the signal is dominated by the force noise acting on test masses. At the same time, the mission duration is limited to 90 days and typical data segments will be 24 hours in length. Considering those constraints, noise analysis is expected to deal with a limited amount of non-Gaussian data, since the spectrum statistics will be far from Gaussian and the lowest available frequency is limited by the data length. In this paper, we analyze the details of the expected statistics for spectral data and develop two suitable excess noise estimators. One is based on the statistical properties of the integrated spectrum, the other is based on the Kolmogorov-Smirnov test. The sensitivity of the estimators is discussed theoretically for independent data, then the algorithms are tested on LPF synthetic data. The test on realistic LPF data allows the effect of spectral data correlations on the efficiency of the different noise excess estimators to be highlighted. It also reveals the versatility of the Kolmogorov-Smirnov approach, which can be adapted to provide reasonable results on correlated data from a modified version of the standard equations for the inversion of the test statistic. Closely related to excess noise

  18. Vibration and noise analysis in nuclear power plants

    International Nuclear Information System (INIS)

    1974-12-01

    Results of the investigations on noise and vibration analysis are presented as a follow-up study of the work published in ''On-load Surveillance of Nuclear Power Plant Components by Noise and Vibration Analysis'' EUR 5036 e. The state of the art in on-load surveillance techniques of light water reactors is given by extending the preceding studies to investigations of boiling water reactors and by summarizing the latest results of pressurized water reactors, the basis being experimental and theoretical work performed by the different organizations involved in preparing this report. Finally, some developments with respect to measurement and identification methods are discussed

  19. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  20. Electrochemical noise of the erosion-corrosion of copper in relation with its hydrodynamic parameters; Ruido electroquimico de la erosion-corrosion en cobre: su relacion con los parametros hidrodinamicos

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, I.; Romero, M.; Malo, J.M.; Uruchurtu, J.

    2010-07-01

    This work presents the electrochemical noise results obtained of the surface degradation on copper, due to erosion corrosion phenomena, which were a function of the hydrodynamic parameters of the system (fluid movement). A modified rotating cylinder (RC) comprising three ring electrodes under two rotating speeds (880 and 1750 rpm with a Reynolds numbers 1486 Re and 2972 Re, respectively) were used. Characteristic electrochemical noise spectra as a function of the hydrodynamic parameters were found, as well as surface attack intensities the noise signal. An increase and a more uniform attack due to particle impact was related to larger particle size and lesser erosion corrosion intensity, in the form of more localized attack over the surface, was obtained for smaller ones. Erosion corrosion attack presents characteristic electrochemical current and potential noise signals, according to the laminar or transitional turbulent regime and particle size added. (Author).

  1. Technical noise supplement : TeNS : a technical supplement to the Traffic Noise Analysis Protocol.

    Science.gov (United States)

    1998-10-01

    The purpose of this Technical Noise Supplement (TeNS) is to provide technical background : information on transportation-related noise in general and highway traffic noise in : particular. It is designed to elaborate on technical concepts and procedu...

  2. Bedload transport from spectral analysis of seismic noise near rivers

    Science.gov (United States)

    Hsu, L.; Finnegan, N. J.; Brodsky, E. E.

    2010-12-01

    Channel change in rivers is driven by bedload sediment transport. However, the nonlinear nature of sediment transport combined with the difficulty of making direct observations in rivers at flood hinder prediction of the timing and magnitude of bedload movement. Recent studies have shown that spectral analysis of seismic noise from seismometers near rivers illustrate a correlation between the relative amplitude of high frequency (>1 Hz) seismic noise and conditions for bedload transport, presumably from the energy transferred from clast collisions with the channel. However, a previous study in the Himalayas did not contain extensive bedload transport or discharge measurements, and the correspondence of seismic noise with proxy variables such as regional hydrologic and meteorologic data was not exact. A more complete understanding of the relationship between bedload transport and seismic noise would be valuable for extending the spatial and temporal extent of bedload data. To explore the direct relationship between bedload transport and seismic noise, we examine data from several seismic stations near the Trinity River in California, where the fluvial morphodynamics and bedload rating curves have been studied extensively. We compare the relative amplitude of the ambient seismic noise with records of water discharge and sediment transport. We also examine the noise at hourly, daily, and seasonal timescales to determine other possible sources of noise. We report the influence of variables such as local river slope, adjacent geology, anthropogenic noise, and distance from the river. The results illustrate the feasibility of using existing seismic arrays to sense radiated energy from processes of bedload transport. In addition, the results can be used to design future seismic array campaigns to optimize information about bedload transport. This technique provides great spatial and temporal coverage, and can be performed where direct bedload measurements are difficult or

  3. Tipping point analysis of ocean acoustic noise

    Science.gov (United States)

    Livina, Valerie N.; Brouwer, Albert; Harris, Peter; Wang, Lian; Sotirakopoulos, Kostas; Robinson, Stephen

    2018-02-01

    We apply tipping point analysis to a large record of ocean acoustic data to identify the main components of the acoustic dynamical system and study possible bifurcations and transitions of the system. The analysis is based on a statistical physics framework with stochastic modelling, where we represent the observed data as a composition of deterministic and stochastic components estimated from the data using time-series techniques. We analyse long-term and seasonal trends, system states and acoustic fluctuations to reconstruct a one-dimensional stochastic equation to approximate the acoustic dynamical system. We apply potential analysis to acoustic fluctuations and detect several changes in the system states in the past 14 years. These are most likely caused by climatic phenomena. We analyse trends in sound pressure level within different frequency bands and hypothesize a possible anthropogenic impact on the acoustic environment. The tipping point analysis framework provides insight into the structure of the acoustic data and helps identify its dynamic phenomena, correctly reproducing the probability distribution and scaling properties (power-law correlations) of the time series.

  4. Tipping point analysis of ocean acoustic noise

    Directory of Open Access Journals (Sweden)

    V. N. Livina

    2018-02-01

    Full Text Available We apply tipping point analysis to a large record of ocean acoustic data to identify the main components of the acoustic dynamical system and study possible bifurcations and transitions of the system. The analysis is based on a statistical physics framework with stochastic modelling, where we represent the observed data as a composition of deterministic and stochastic components estimated from the data using time-series techniques. We analyse long-term and seasonal trends, system states and acoustic fluctuations to reconstruct a one-dimensional stochastic equation to approximate the acoustic dynamical system. We apply potential analysis to acoustic fluctuations and detect several changes in the system states in the past 14 years. These are most likely caused by climatic phenomena. We analyse trends in sound pressure level within different frequency bands and hypothesize a possible anthropogenic impact on the acoustic environment. The tipping point analysis framework provides insight into the structure of the acoustic data and helps identify its dynamic phenomena, correctly reproducing the probability distribution and scaling properties (power-law correlations of the time series.

  5. Noise removing in encrypted color images by statistical analysis

    Science.gov (United States)

    Islam, N.; Puech, W.

    2012-03-01

    Cryptographic techniques are used to secure confidential data from unauthorized access but these techniques are very sensitive to noise. A single bit change in encrypted data can have catastrophic impact over the decrypted data. This paper addresses the problem of removing bit error in visual data which are encrypted using AES algorithm in the CBC mode. In order to remove the noise, a method is proposed which is based on the statistical analysis of each block during the decryption. The proposed method exploits local statistics of the visual data and confusion/diffusion properties of the encryption algorithm to remove the errors. Experimental results show that the proposed method can be used at the receiving end for the possible solution for noise removing in visual data in encrypted domain.

  6. Analysis of a Shock-Associated Noise Prediction Model Using Measured Jet Far-Field Noise Data

    Science.gov (United States)

    Dahl, Milo D.; Sharpe, Jacob A.

    2014-01-01

    A code for predicting supersonic jet broadband shock-associated noise was assessed using a database containing noise measurements of a jet issuing from a convergent nozzle. The jet was operated at 24 conditions covering six fully expanded Mach numbers with four total temperature ratios. To enable comparisons of the predicted shock-associated noise component spectra with data, the measured total jet noise spectra were separated into mixing noise and shock-associated noise component spectra. Comparisons between predicted and measured shock-associated noise component spectra were used to identify deficiencies in the prediction model. Proposed revisions to the model, based on a study of the overall sound pressure levels for the shock-associated noise component of the measured data, a sensitivity analysis of the model parameters with emphasis on the definition of the convection velocity parameter, and a least-squares fit of the predicted to the measured shock-associated noise component spectra, resulted in a new definition for the source strength spectrum in the model. An error analysis showed that the average error in the predicted spectra was reduced by as much as 3.5 dB for the revised model relative to the average error for the original model.

  7. Analysis of electrochemical disintegration process of graphite matrix

    International Nuclear Information System (INIS)

    Tian Lifang; Wen Mingfen; Chen Jing

    2010-01-01

    The electrochemical method with ammonium nitrate as electrolyte was studied to disintegrate the graphite matrix from the simulative fuel elements for high temperature gas-cooled reactor. The influences of process parameters, including salt concentration, system temperature and current density, on the disintegration rate of graphite fragments were investigated in the present work. The experimental results showed that the disintegration rate depended slightly on the temperature and salt concentration. The current density strongly affected the disintegration rate of graphite fragments. Furthermore, the content of introduced oxygen in final graphite fragments was independent of the current density and the concentration of electrolyte. Moreover, the structural evolution of graphite was analyzed based on the microstructural parameters determined by X-ray diffraction profile fitting analysis using MAUD (material analysis using diffraction) before and after the disintegration process. It may safely be concluded that the graphite disintegration can be ascribed to the influences of the intercalation of foreign molecules in between crystal planes and the partial oxidation involved. The disintegration process was described deeply composed of intercalate part and further oxidation part of carbon which effected together to lead to the collapse of graphite crystals.

  8. Noise Measurement and Frequency Analysis of Commercially Available Noisy Toys

    Directory of Open Access Journals (Sweden)

    Shohreh Jalaie

    2005-06-01

    Full Text Available Objective: Noise measurement and frequency analysis of commercially available noisy toys were the main purposes of the study. Materials and Methods: 181 noisy toys commonly found in toy stores in different zones of Tehran were selected and categorized into 10 groups. Noise measurement were done at 2, 25, and 50 cm from toys in dBA. The noisiest toy of each group was frequency analyzed in octave bands. Results: The highest and the lowest intensity levels belonged to the gun (mean=112 dBA and range of 100-127 dBA and to the rattle-box (mean=84 dBA and range of 74-95 dBA, respectively. Noise intensity levels significantly decreased with increasing distance except for two toys. Noise frequency analysis indicated energy in effective hearing frequencies. Most of the toys energies were in the middle and high frequency region. Conclusion: As intensity level of the toys is considerable, mostly more than 90 dBA, and also their energy exist in the middle and high frequency region, toys should be considered as a cause of the hearing impairment.

  9. Sensitivity of PPI analysis to differences in noise reduction strategies.

    Science.gov (United States)

    Barton, M; Marecek, R; Rektor, I; Filip, P; Janousova, E; Mikl, M

    2015-09-30

    In some fields of fMRI data analysis, using correct methods for dealing with noise is crucial for achieving meaningful results. This paper provides a quantitative assessment of the effects of different preprocessing and noise filtering strategies on psychophysiological interactions (PPI) methods for analyzing fMRI data where noise management has not yet been established. Both real and simulated fMRI data were used to assess these effects. Four regions of interest (ROIs) were chosen for the PPI analysis on the basis of their engagement during two tasks. PPI analysis was performed for 32 different preprocessing and analysis settings, which included data filtering with RETROICOR or no such filtering; different filtering of the ROI "seed" signal with a nuisance data-driven time series; and the involvement of these data-driven time series in the subsequent PPI GLM analysis. The extent of the statistically significant results was quantified at the group level using simple descriptive statistics. Simulated data were generated to assess statistical improvement of different filtering strategies. We observed that different approaches for dealing with noise in PPI analysis yield differing results in real data. In simulated data, we found RETROICOR, seed signal filtering and the addition of data-driven covariates to the PPI design matrix significantly improves results. We recommend the use of RETROICOR, and data-driven filtering of the whole data, or alternatively, seed signal filtering with data-driven signals and the addition of data-driven covariates to the PPI design matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Noise Source Identification of a Ring-Plate Cycloid Reducer Based on Coherence Analysis

    OpenAIRE

    Yang, Bing; Liu, Yan

    2013-01-01

    A ring-plate-type cycloid speed reducer is one of the most important reducers owing to its low volume, compactness, smooth and high performance, and high reliability. The vibration and noise tests of the reducer prototype are completed using the HEAD acoustics multichannel noise test and analysis system. The characteristics of the vibration and noise are obtained based on coherence analysis and the noise sources are identified. The conclusions provide the bases for further noise research and ...

  11. Neutron noise analysis of BWR using time series analysis

    International Nuclear Information System (INIS)

    Fukunishi, Kohyu

    1976-01-01

    The main purpose of this paper is to give more quantitative understanding of noise source in neutron flux and to provide a useful tool for the detection and diagnosis of reactor. The space dependent effects of distributed neutron flux signals at the axial direction of two different strings are investigated by the power contribution ratio among neutron fluxes and the incoherent noise spectra of neutron fluxes derived from autoregressive spectra. The signals are measured on the medium sized commercial BWR of 460 MWe in Japan. From the obtained results, local and global noise sources in neutron flux are discussed. This method is indicated to be a useful tool for detection and diagnosis of anomalous phenomena in BWR. (orig./RW) [de

  12. Reactor noise analysis of experimental fast reactor 'JOYO'

    International Nuclear Information System (INIS)

    Ohtani, Hideji; Yamamoto, Hisashi

    1980-01-01

    As a part of dynamics tests in experimental fast reactor ''JOYO'', reactor noise tests were carried out. The reactor noise analysis techniques are effective for study of plant characteristics by determining fluctuations of process signals (neutron signal, reactor inlet temperature signals, etc.), which are able to be measured without disturbances for reactor operations. The aims of reactor noise tests were to confirm that no unstable phenomenon exists in ''JOYO'' and to gain initial data of the plant for reference of the future data. Data for the reactor noise tests treated in this paper were obtained at 50 MW power level. Fluctuations of process signals were amplified and recorded on analogue tapes. The analysis was performed using noise code (NOISA) of digital computer, with which statistical values of ASPD (auto power spectral density), CPSD (cross power spectral density), and CF (coherence function) were calculated. The primary points of the results are as follows. 1. RMS value of neutron signal at 50 MW power level is about 0.03 MW. This neutron fluctuation is not disturbing reactor operations. 2. The fluctuations of A loop reactor inlet temperatures (T sub(AI)) are larger than the fluctuations of B loop reactor inlet temperature (T sub(BI)). For this reason, the major driving force of neutron fluctuations seems to be the fluctuations of T sub(AI). 3. Core and blanket subassemblies can be divided into two halves (A and B region), with respect to the spacial motion of temperature in the reactor core. A or B region means the region in which sodium temperature fluctuations in subassembly are significantly affected by T sub(AI) or T sub(BI), respectively. This phenomenon seems to be due to the lack of mixing of A and B loop sodium in lower plenum of reactor vessel. (author)

  13. Electrochemical capacity fading of polyaniline electrode in supercapacitor: An XPS analysis

    Directory of Open Access Journals (Sweden)

    Jinxing Deng

    2017-04-01

    Full Text Available To understand the electrochemical capacity fading of the polyaniline (PANI electrodes in supercapacitors, for the first time, their chemical structure change during electrochemical cycles was traced with XPS analysis after the HCl doped PANI electrodes were subjected to the cyclic voltammetry test in 1.0 M H2SO4 electrolyte for different cycle numbers. The results showed that the chlorine disappeared in the electrode surface, while the surface element contents of sulfur and oxygen increased with the electrochemical cycles increased. It demonstrated that the hydrolytic degradation of the PANI chains and exchange of dopant occurred during the electrochemical cycling, causing the fading in the mechanical and electrochemical performance of the PANI electrodes. This understanding should lead to better design of the conductive polymer-based energy storage devices.

  14. Data acquisition and processing system for reactor noise analysis

    International Nuclear Information System (INIS)

    Costa Oliveira, J.; Morais Da Veiga, C.; Forjaz Trigueiros, D.; Pombo Duarte, J.

    1975-01-01

    A data acquisition and processing system for reactor noise analysis by time correlation methods is described, consisting in one to four data feeding channels (transducer, associated electronics and V/f converter), a sampling unit, a landline transmission system and a PDP 15 computer. This system is being applied to study the kinetic parameters of the 'Reactor Portugues de Investigacao', a swimming-pool 1MW reactor. The main features that make such a data acquisition and processing system a useful tool to perform noise analysis are: the improved characteristics of analog-to-digital converters employed to quantize the signals; the use of an on-line computer which allows a great accumulation and a rapid treatment of data together with an easy check of the correctness of the experiments; and the adoption of the time cross-correlation technique using two-detectors which by-pass the limitation of low efficiency detectors. (author)

  15. NOASYS, a system for on-line noise analysis

    International Nuclear Information System (INIS)

    Massier, H.

    1978-07-01

    This report describes NOASYS, a versatile NOise Analysis SYStem for digital on-line signal processing. The system based on a minicomputer, was originally developed for the analysis of noise signals from nuclear reactors. NOASYS computes various statistical functions e.g. cross- und auto-correlation functions and power spectral densities resp., which may be used for reactor diagnosis and malfunction detection. The system processes up to 16 analog signals with a maximum sampling frequency of 100 kcps (1 channel). The processing of the sampled data is done by a number of software tasks, which may be called from a teletype or linked together for specific measuring programs. The standard configuration contains the often used processing routines e.g. Fast Fourier Transform, complex multiplication, summation etc. In addition NOASYS may be extended by users own tasks (in Assembler or Fortran) to fit for specific applications. (orig.) 891 HP [de

  16. Coupled Mechanical-Electrochemical-Thermal Analysis of Failure Propagation in Lithium-ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chao; Santhanagopalan, Shriram; Pesaran, Ahmad

    2016-07-28

    This is a presentation given at the 12th World Congress for Computational Mechanics on coupled mechanical-electrochemical-thermal analysis of failure propagation in lithium-ion batteries for electric vehicles.

  17. Current applications of vibration monitoring and neutron noise analysis

    International Nuclear Information System (INIS)

    Damiano, B.; Kryter, R.C.

    1990-02-01

    Monitoring programs using vibration monitoring or neutron noise analysis have demonstrated the ability to detect and, in some cases, diagnose the nature of reactor vessel internals structural degradation. Detection of compromised mechanical integrity of reactor vessel internal components in its early stages allows corrective action to be taken before weakening or damage occurs. In addition to the economic benefits early detection and correction can provide, they can also help maintain plant safety. Information on the condition of reactor vessel internal components gained from a monitoring program supplements in-service inspection results and may be useful in justifying plant license extension. This report, which was prepared under the Nuclear Plant Aging Research Program sponsored by the US Nuclear Regulatory Commission, discusses the application of vibration monitoring and neutron noise analysis for monitoring light-water reactor vessel internals. The report begins by describing the effects of structural integrity loss on internals vibration and how measurable parameters can be used to detect and track the progress of degradation. This is followed by a description and comparison of vibration monitoring and neutron noise analysis, two methods for monitoring the mechanical integrity of reactor vessel internals condition monitoring programs in the United States, Federal Republic of Germany, and France, three countries having substantial commitments to nuclear power. The last section presents guidelines for US utilities wishing to establish reactor internals condition monitoring programs. 20 refs., 5 figs., 4 tabs

  18. Analysis of Noise Mechanisms in Cell-Size Control.

    Science.gov (United States)

    Modi, Saurabh; Vargas-Garcia, Cesar Augusto; Ghusinga, Khem Raj; Singh, Abhyudai

    2017-06-06

    At the single-cell level, noise arises from multiple sources, such as inherent stochasticity of biomolecular processes, random partitioning of resources at division, and fluctuations in cellular growth rates. How these diverse noise mechanisms combine to drive variations in cell size within an isoclonal population is not well understood. Here, we investigate the contributions of different noise sources in well-known paradigms of cell-size control, such as adder (division occurs after adding a fixed size from birth), sizer (division occurs after reaching a size threshold), and timer (division occurs after a fixed time from birth). Analysis reveals that variation in cell size is most sensitive to errors in partitioning of volume among daughter cells, and not surprisingly, this process is well regulated among microbes. Moreover, depending on the dominant noise mechanism, different size-control strategies (or a combination of them) provide efficient buffering of size variations. We further explore mixer models of size control, where a timer phase precedes/follows an adder, as has been proposed in Caulobacter crescentus. Although mixing a timer and an adder can sometimes attenuate size variations, it invariably leads to higher-order moments growing unboundedly over time. This results in a power-law distribution for the cell size, with an exponent that depends inversely on the noise in the timer phase. Consistent with theory, we find evidence of power-law statistics in the tail of C. crescentus cell-size distribution, although there is a discrepancy between the observed power-law exponent and that predicted from the noise parameters. The discrepancy, however, is removed after data reveal that the size added by individual newborns in the adder phase itself exhibits power-law statistics. Taken together, this study provides key insights into the role of noise mechanisms in size homeostasis, and suggests an inextricable link between timer-based models of size control and

  19. Properties of autoregressive model in reactor noise analysis, 1

    International Nuclear Information System (INIS)

    Yamada, Sumasu; Kishida, Kuniharu; Bekki, Keisuke.

    1987-01-01

    Under appropriate conditions, stochastic processes are described by the ARMA model, however, the AR model is popularly used in reactor noise analysis. Hence, the properties of AR model as an approximate representation of the ARMA model should be made clear. Here, convergence of AR-parameters and PSD of AR model were studied through numerical analysis on specific examples such as the neutron noise in subcritical reactors, and it was found that : (1) The convergence of AR-parameters and AR model PSD is governed by the ''zero nearest to the unit circle in the complex plane'' (μ -1 ,|μ| M . (3) The AR model of the neutron noise of subcritical reactors needs a large model order because of an ARMA-zero very close to unity corresponding to the decay constant of the 6-th group of delayed neutron precursors. (4) In applying AR model for system identification, much attention has to be paid to a priori unknown error as an approximate representation of the ARMA model in addition to the statistical errors. (author)

  20. Diode laser pumped solid state laser. Part IV. ; Noise analysis. Handotai laser reiki kotai laser. 4. ; Noise kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, H.; Seno, T.; Tanabe, Y. (Asahi Glass Co. Ltd., Tokyo (Japan))

    1991-06-10

    Concerning the second harmonic generation(SHG) of diode laser pumped solid state laser using a nonlinear optical material, the researches are carried out to pracitically apply to the optical pickup. Therefore, the reduction of output optical noise has become the important researching subject. The theoretical and experimental analyses of noise generating mechanism were carried out for the system in which Nd;YAG as the laser diode and KTP (KTiOPO {sub 4}) as the nonlinear optical crystal were used. The following findings for the noise generating mechanism could be obtained: The competitive interaction between the polarization modes was dominant noise mechanism in the high frequency range from 1 to 20MHz and the noise could be removed sufficiently by using the QWP(quarter wave plate). On the other hand, the noise observed in the low frequency range from 100 to 200kHz depended on the resonance length, agreed qualitatively with the theoretical analysis of the noise to the competitive longitudinal modes and agreed quantitatively with the noise generating frequency range. 10 refs., 13 figs., 1 tab.

  1. Graphene Ink Film Based Electrochemical Detector for Paracetamol Analysis

    Directory of Open Access Journals (Sweden)

    Li Fu

    2018-01-01

    Full Text Available Graphene ink is a commercialized product in the graphene industry with promising potential application in electronic device design. However, the limitation of the graphene ink is its low electronic performance due to the ink preparation protocol. In this work, we proposed a simple post-treatment of graphene ink coating via electrochemical oxidation. The electronic conductivity of the graphene ink coating was enhanced as expected after the treatment. The proposed electrochemical oxidation treatment also exposes the defects of graphene and triggered an electrocatalytic reaction during the sensing of paracetamol (PA. The overpotential of redox is much lower than conventional PA redox potential, which is favorable for avoiding the interference species. Under optimum conditions, the graphene ink-based electrochemical sensor could linearly detect PA from 10 to 500 micro molar (μM, with a limit of detection of 2.7 μM.

  2. Identification of multivariate models for noise analysis of nuclear plant

    International Nuclear Information System (INIS)

    Zwingelstein, G.C.; Upadhyaya, B.R.

    1979-01-01

    During the normal operation of a pressurized water reactor, neutron noise analysis with multivariate autoregressive procedures in a valuable diagnostic tool to extract dynamic characteristics for incipient failure detection. The first part of the paper will describe in details the equations for estimating the multivariate autoregressive model matrices and the structure of various matrices. The matrices are estimated by solving a set of matrix operations, called Yule-Walker equations. The selection of optimal model order will also be discussed. Once the optimal parameter set is obtained, simple and fast calculations are used to determine the auto power spectral density, cross spectra, coherence function, phase. In addition the spectra may be decomposed into components being contributed from different noise sources. An application using neutron flux data collected on a nuclear plant will illustrate the efficiency of the method

  3. Identifying functions for ex-core neutron noise analysis

    International Nuclear Information System (INIS)

    Avila, J.M.; Oliveira, J.C.

    1987-01-01

    A method of performing the phase analysis of signals arising from neutron detectors placed in the periphery of a pressurized water reactor is proposed. It consists in the definition of several identifying functions, based on the phases of cross power spectral densities corresponding to four ex-core neutron detectors. Each of these functions enhances the appearance of different sources of noise. The method, applied to the ex-core neutron fluctuation analysis of a French PWR, proved to be very useful as it allows quick recognition of various patterns in the power spectral densities. (orig.) [de

  4. Measurements and analysis of neutron and gamma noise in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van; Kleiss, E.B.J.

    1985-01-01

    Neutron and gamma sensitive collectrons (self-powered detectors) have been designed for incore noise measurements in BWRs. A so-called twin-type has been developed for measurements of two-phase flow characteristics and detailed axial velocity distributions. Construction aspects of the twin detectors are discussed. An analysis is presented of the response of both detector types to incore parametric fluctuations. This analysis is based on detector response functions which provide an insight into the 'field of view' of the two types. The results are supported by experimental verifications; it is shown that incore gamma detectors provide useful additional information about two-phase flow in a BWR. (author)

  5. State of the art on reactor noise analysis

    International Nuclear Information System (INIS)

    Bernard, P.; Fry, D.; Stegemann, D.; Van Dam, H.

    1986-01-01

    This report is the result of the work of a task force sponsored by the NEA Committee on Reactor Physics (NEACRP) and is divided into six chapters: 1. Loose-Parts Detection and Acoustic Monitoring, 2. Thermal Hydraulics Surveillance, 3. Flow Measurements, 4. Vibration Monitoring, 5. Surveillance Systems and Evaluation Methods, and 6. System Dynamic Analysis. Each chapter summarizes the current situation in noise analysis techniques with emphasis on the following aspects: . physical quantities considered, . possible anomalies involved, . sensors used for the detection, and . conditions of applications. The remainder of each chapter discusses future trends and recommendations

  6. Electrochemical Noise Sensors for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines. Final Report for the Period July 2001-October 2002

    Energy Technology Data Exchange (ETDEWEB)

    Bullard, Sophie J.; Covino, Jr., Bernard S.; Russell, James H.; Holcomb, Gordon R.; Cramer, Stephen D.; Ziomek-Moroz, Margaret

    2002-12-01

    The U.S. Department of Energy, National Energy Technology Laboratory funded a Natural Gas Infrastructure Reliability program directed at increasing and enhancing research and development activities in topics such as remote leak detection, pipe inspection, and repair technologies and materials. The Albany Research Center (ARC), U.S. Department of Energy was funded to study the use of electrochemical noise sensors for detection of localized and general corrosion of natural gas transmission pipelines. As part of this, ARC entered into a collaborative effort with the corrosion sensor industry to demonstrate the capabilities of commercially available remote corrosion sensors for use with the Nation's Gas Transmission Pipeline Infrastructure needs. The goal of the research was to develop an emerging corrosion sensor technology into a monitor for the type and degree of corrosion occurring at key locations in gas transmission pipelines.

  7. Electrochemical noise study on 2024-T3 Aluminum alloy corrosion in simulated acid rain under cyclic wet-dry condition

    International Nuclear Information System (INIS)

    Shi Yanyan; Zhang Zhao; Su Jingxin; Cao Fahe; Zhang Jianqing

    2006-01-01

    Potential noise records have been collected for 2024-T3 aluminum alloy, which was exposed to simulated acid rain with different pH value for 15 wet-dry cycles. Meanwhile, Potentiodynamic polarization and SEM techniques were also used as assistant measurements. Three mathematic methods including average, standard deviation and wavelet transformation have been employed to analyze the records. The results showed that each single wet-dry cycle can be divided into three regions with respect to the change of the cathodic reaction rate, and with the increase of pH value the main cathodic reaction changes from the reduction of protons to that of oxygen molecules. The analysis of the EDP versus time evolution clearly indicates that the whole corrosion process can be divided into three segments for the case of pH 3.5 and only one for the cases of pH 4.5 and 6.0, which have been theoretically interpreted according to the corrosion theory and experimentally proved by SEM. The results also showed that the corrosion in the case of pH 3.5 was much more rigorous than that in the cases of pH 4.5 and 6.0. It may due to synergistic effects of that, the characteristic of hydrogen ions which is much more active than that of oxygen molecules, the high diffusion/migration rate of hydrogen ions in solution or through surface films and the lower stability of surface passive film at low pH value system

  8. Noise analysis role in reactor safety, Spectral analysis (PSD)

    International Nuclear Information System (INIS)

    Jovanovic, S.; Velickovic, Lj.

    1967-11-01

    Spectral power density of a zero power reactor is frequency dependent and related to transfer function of the reactor and to spectral density of the input disturbance. Measurement of spectral power density of a critical system is used to obtain the ratio (β/l), β is the effective yield of delayed neutrons, and l is the effective mean neutron lifetime. When reactor is subcritical, if the effective yie ald of delayed neutrons, the effective mean neutron lifetime are known, the shutdown margin can be determined by relation α = (1 - k (1- β0)/l, k is the effective multiplication factor. Output neutron spectrum at the RB reactor in Vinca was measured for a few reactor core configurations and for a few levels of heavy water at subcritical state. Measured values were satisfactory when the reactor was critical, but the reactor noise of subcritical system was covered by the white noise of the detector and electronic equipment. The Ra-Be source was under the reactor vessel when measurements of subcritical system were done. More efficient detector or external random stimulus for increasing the intensity of neutron fluctuations would be needed to obtain results for subcritical system

  9. Identification of nuclear reactor characteristics by the reactor noise analysis

    International Nuclear Information System (INIS)

    Yashima, Hideyuki

    1980-01-01

    Reactor noise analysis method was applied to TRIGA II Research Reactor (Atomic Research Laboratory, Musashi Institute of Technology) and computed power spectral density (PSD) from the CIC current record. PSD has provided many valuable informations regarding to the reactor kinetics, including the effect of control rods vibration. Another information of neutron physics parameters were obtained and this result was compared with the parameter which was formerly measured by the Feynman-α experiment. Through these experiments we could find overall frequency characteristics of TRIGA II Reactor. (author)

  10. The noise analysis and the BWR operation map

    International Nuclear Information System (INIS)

    Blazquez, J.; Ballestrin, J.

    1996-01-01

    An analytical expression for the Decay Ratio is obtained: DR = exp(-bW / P 1/2 ). The physics behind is also explained. It applies to a commercial BWR Operation Map, on the vicinity of the power instability. This functional form seems fitting to the structure of the Operation map. The power P and the coolant flow are measured straightforward; the Decay Ratio is obtained by neutron noise analysis techniques. The parameter b, depending on the void reactivity coefficient, is then calculated on line during the Reactor Operation. New DR value is now predicted for each new displacement on the Map, so unexpected instability events are more likely avoided. (authors)

  11. Noise suppression and crosstalk analysis of on-chip magnetic film-type noise suppressor

    Science.gov (United States)

    Ma, Jingyan; Muroga, Sho; Endo, Yasushi; Hashi, Shuichiro; Naoe, Masayuki; Yokoyama, Hiroo; Hayashi, Yoshiaki; Ishiyama, Kazushi

    2018-05-01

    This paper discusses near field, conduction and crosstalk noise suppression of magnetic films with uniaxial anisotropy on transmission lines for a film-type noise suppressor in the GHz frequency range. The electromagnetic noise suppressions of magnetic films with different permeability and resistivity were measured and simulated with simple microstrip lines. The experimental and simulated results of Co-Zr-Nb and CoPd-CaF2 films agreed with each other. The results indicate that the higher permeability leads to a better near field shielding, and in the frequency range of 2-7 GHz, a higher conduction noise suppression. It also suggests that the higher resistivity results in a better crosstalk suppression in the frequency range below 2 GHz. These results can support the design guidelines of the magnetic film-type noise suppressor used in the next generation IC chip.

  12. Lifetime measurement of prompt neutrons using the neutronic noise analysis

    International Nuclear Information System (INIS)

    Ortiz Servin, J.J.

    1992-01-01

    The purpose of this work is to estimate the life of the prompt neutrons, i, of a nuclear reactor utilizing the neutron noise analysis. This technique carry to development of mathematical model that is valid for lower powers reactor. The equation resulting convey to the observation about power spectrum behaviour respect to the frecquency. In this case, the reactor in study is the Triga Mark III of Nuclear Center of Mexico that it was provided of fission chambers for register the neutron fluxes. These fluxes was digitized and storage in computer disc as signals dependents of time, for later apply the Fourier Transformation and obtain the spectras. The spectras measured to different reactor powers were adjusted to the development equation before, using the method of square minimum and so estimate the parameter i. The analysis of results throw a value of 22.73 +/- 0.92 μs. On the other hand, the calculate value to the resolve the kinetic equation of reactor defer in lower than 4 % about the estimate. Of this, it concludes that the model utilized is trusty with a good mistake margin, moreover of that the technique of Neutron Noise analysis demonstrate be competitive (Author)

  13. Diagnosis methods based on noise analysis at Cernavoda NPP, Romania

    International Nuclear Information System (INIS)

    Banica, Constantin; Dobrea, Dumitru

    1999-01-01

    This paper describes a recent noise analysis of the neutronic signals provided by in-core flux detectors (ICFD) and ion chambers (IC). This analysis is part of on-going program developed for Unit 1 of the Cernavoda NPP, Romania, with the following main objectives: - prediction of detector failures based on pattern recognition; - determination of fast excursions from steady states; - detection of abnormal mechanical vibrations in the reactor core. The introduction presents briefly the reactor, the location of ICFD's and IC's. The second section presents the data acquisition systems and their capabilities. The paper continues with a brief presentation of the numerical methods used for analysis (section 3). The most significant results can be found in section 4, while section 5 concludes about useful information that can be obtained from the neutronic signals at high power steady-state operation. (authors)

  14. Utility experience in reactor noise analysis in German LWRs

    International Nuclear Information System (INIS)

    Schuette, A.; Weingarten, J.; Wach, D.

    1988-01-01

    Reactor noise analysis has a long history in Fed. Rep. of Germany. Since the early 60ies it was directed to early fault, malfunction and anomaly detection in nuclear power plants. When successful diagnoses showed the high potential and benefits including economic and safety aspects, also the utilities began to have a vivid concern in application of the developed methods and systems. The know-how transfer from specialized teams to the onsite personnel as well as the development of more ''intelligent'' online systems are important present and future tasks for further improvement of their efficiency. The diagnostic group of GRS is active in both fields and has close cooperation with several utilities to achieve these objectives. Modern signal processing equipment and access to a comprehensive knowledge base stored in data banks are provided by the data analysis center of GRS. The available capabilities are described and examples of analysis results within the cooperation utilities/GRS are given. (author)

  15. Noise analysis and performance of a selfscanned linear InSb detector array

    International Nuclear Information System (INIS)

    Finger, G.; Meyer, M.; Moorwood, A.F.M.

    1987-01-01

    A noise model for detectors operated in the capacitive discharge mode is presented. It is used to analyze the noise performance of the ESO nested timing readout technique applied to a linear 32-element InSb array which is multiplexed by a silicon switched-FET shift register. Analysis shows that KTC noise of the videoline is the major noise contribution; it can be eliminated by weighted double-correlated sampling. Best noise performance of this array is achieved at the smallest possible reverse bias voltage (not more than 20 mV) whereas excess noise is observed at higher reverse bias voltages. 5 references

  16. Applications of aero-acoustic analysis to wind turbine noise control

    International Nuclear Information System (INIS)

    Lowson, M.V.

    1992-01-01

    Wind turbine noise generation mechanisms are essentially equivalent to the aero-acoustic mechanisms of other rotors, which have been studied in depth for many years. Basic sources for the wind turbine noise radiation process are defined, and their significance assessed. From the analysis, areas of potential improvement in wind turbine noise prediction are defined. Suggestions are made for approaches to wind turbine noise control which separate the noise problems at cut-in from those at rated power. Some of these offer the possibility of noise reduction without unfavourable effects on performance. (author)

  17. Applications of aero-acoustic analysis to wind turbine noise control

    International Nuclear Information System (INIS)

    Lowson, M.

    1993-01-01

    Wind turbine noise generation mechanisms are essentially equivalent to the aero-acoustic mechanisms of other rotors, which have been studied in depth for many years. Basic sources for the wind turbine noise radiation process are defined, and their significance assessed. From the analysis, areas of potential improvement in wind turbine noise prediction are defined. Suggestions are made for approaches to wind turbine noise control which separate the noise problems at cut-in from those at rated power. Some of these offer the possibility of noise reduction without unfavourable effects on performance. (author)

  18. Analysis of modeling aircraft noise with the Nord2000 noise model

    Science.gov (United States)

    2012-10-31

    This report provides comparisons between AEDT/INM and the Nord 2000 Noise Models for the following parameters: ground type, simple terrain (downward slope, upward slope, hill), temperature and humidity, temperature gradients (positive and negative), ...

  19. Rotary Compressor Noise Analysis Using Mechanisms and Electromagnetics Coupled Approach

    OpenAIRE

    Chung, Jinah; Lee, Uiyoon; Lee, Jeongbae; Lee, Unseop; Han, Eunsil; Yoon, Jinhwan

    2016-01-01

    This research is conducted to investigate noise source and design low noise compressors. For improving energy efficiency, the rotary compressor with variable speed brushless DC motor is increasingly adopted for appliances. However brushless DC motor makes more compressor vibration than constant speed motor compressor at high speed operating condition. Therefore it is necessary to reduce noise and vibration for improving air conditioner quality. In this study, compressor’s noise and vibrat...

  20. Fermeuse wind power project Newfoundland : noise and visual analysis studies

    Energy Technology Data Exchange (ETDEWEB)

    Henn, P.; Turgeon, J.; Heraud, P.; Belanger, S.; Dakousian, S.; Lamontagne, C.; Soares, D. [Helimax Energy Inc., Montreal, PQ (Canada); Basil, C.; Boulianne, S.; Salacup, S.; Thompson, C. [Skypower, Toronto, ON (Canada)

    2008-03-15

    This paper discussed the noise and visual analyses used to assess the potential impacts of a wind energy project on the east coast of the Avalon Peninsula near St. John's, Newfoundland. The proposed farm will be located approximately 1 km away from the town of Fermeuse, and will have an installed capacity of 27 MW from 9 turbines. The paper provided details of the consultation process conducted to determine acceptable distance and site locations for the wind turbines from the community. Stakeholders were identified during meetings, events, and discussions with local authorities. Consultations were also held with government agencies and municipal councils. A baseline acoustic environment study was conducted, and details of anticipated environmental impacts during the project's construction, operation, and decommissioning phases were presented. The visual analysis study was divided into the following landscape units: town, shoreline, forest, open land and lacustrine landscapes. The effect of the turbines on the landscapes were assessed from different viewpoints using visual simulation programs. The study showed that the visual effects of the project are not considered as significant because of the low number of turbines. It was concluded that the effect of construction on ambient noise levels is of low concern as all permanent dwellings are located at least 1 km away from the turbines. 2 refs., 4 tabs., 4 figs.

  1. Noise Source Identification of a Ring-Plate Cycloid Reducer Based on Coherence Analysis

    Directory of Open Access Journals (Sweden)

    Bing Yang

    2013-01-01

    Full Text Available A ring-plate-type cycloid speed reducer is one of the most important reducers owing to its low volume, compactness, smooth and high performance, and high reliability. The vibration and noise tests of the reducer prototype are completed using the HEAD acoustics multichannel noise test and analysis system. The characteristics of the vibration and noise are obtained based on coherence analysis and the noise sources are identified. The conclusions provide the bases for further noise research and control of the ring-plate-type cycloid reducer.

  2. Integrated Electrochemical Analysis System with Microfluidic and Sensing Functions

    Directory of Open Access Journals (Sweden)

    Hiroaki Suzuki

    2008-02-01

    Full Text Available An integrated device that carries out the timely transport of solutions andconducts electroanalysis was constructed. The transport of solutions was based oncapillary action in overall hydrophilic flow channels and control by valves that operateon the basis of electrowetting. Electrochemical sensors including glucose, lactate,glutamic oxaloacetic transaminase (GOT, glutamic pyruvic transaminase (GPT, pH,ammonia, urea, and creatinine were integrated. An air gap structure was used for theammonia, urea, and creatinine sensors to realize a rapid response. To enhance thetransport of ammonia that existed or was produced by the enzymatic reactions, the pHof the solution was elevated by mixing it with a NaOH solution using a valve based onelectrowetting. The sensors for GOT and GPT used a freeze-dried substrate matrix torealize rapid mixing. The sample solution was transported to required sensing sites atdesired times. The integrated sensors showed distinct responses when a sample solutionreached the respective sensing sites. Linear relationships were observed between theoutput signals and the concentration or the logarithm of the concentration of theanalytes. An interferent, L-ascorbic acid, could be eliminated electrochemically in thesample injection port.

  3. Electrochemical analysis in a liposome suspension using lapachol as a hydrophobic electro active species.

    Science.gov (United States)

    Okumura, Noriko; Wakamatsu, Shiori; Uno, Bunji

    2014-01-01

    This study demonstrated that the electro-chemical analysis of hydrophobic quinones can be performed in liposome suspension systems. We prepared and analyzed liposome suspensions containing lapachol, which is a quinone-based anti-tumor activity compound. In this suspension system, a simple one redox couple of lapachol is observed. These results are quite different from those obtained in organic solvents. In addition, the pH dependence of redox behaviors of lapachol could be observed in multilamellar vesicle (MLV) suspension system. This MLV suspension system method may approximate the electrochemical behavior of hydrophobic compounds in aqueous conditions. A benefit of this liposome suspension system for electrochemical analysis is that it enables to observe water-insoluble compounds without using organic solvents.

  4. Multivariate statistical pattern recognition system for reactor noise analysis

    International Nuclear Information System (INIS)

    Gonzalez, R.C.; Howington, L.C.; Sides, W.H. Jr.; Kryter, R.C.

    1976-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis was developed. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, and updating capabilities. System design emphasizes control of the false-alarm rate. The ability of the system to learn normal patterns of reactor behavior and to recognize deviations from these patterns was evaluated by experiments at the ORNL High-Flux Isotope Reactor (HFIR). Power perturbations of less than 0.1 percent of the mean value in selected frequency ranges were detected by the system

  5. Reactor noise analysis by statistical pattern recognition methods

    International Nuclear Information System (INIS)

    Howington, L.C.; Gonzalez, R.C.

    1976-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis is presented. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, updating, and data compacting capabilities. System design emphasizes control of the false-alarm rate. Its abilities to learn normal patterns, to recognize deviations from these patterns, and to reduce the dimensionality of data with minimum error were evaluated by experiments at the Oak Ridge National Laboratory (ORNL) High-Flux Isotope Reactor. Power perturbations of less than 0.1 percent of the mean value in selected frequency ranges were detected by the pattern recognition system

  6. Multivariate statistical pattern recognition system for reactor noise analysis

    International Nuclear Information System (INIS)

    Gonzalez, R.C.; Howington, L.C.; Sides, W.H. Jr.; Kryter, R.C.

    1975-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis was developed. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, and updating capabilities. System design emphasizes control of the false-alarm rate. The ability of the system to learn normal patterns of reactor behavior and to recognize deviations from these patterns was evaluated by experiments at the ORNL High-Flux Isotope Reactor (HFIR). Power perturbations of less than 0.1 percent of the mean value in selected frequency ranges were detected by the system. 19 references

  7. 252Cf-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; King, W.T.; Blakeman, E.D.

    1985-01-01

    The 252 Cf-source-driven neutron noise analysis method has been tested in a a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor, k/sub eff/ has been satisfactorily determined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments and the development of theoretical methods to predict the experimental observables

  8. PC analysis of stochastic differential equations driven by Wiener noise

    KAUST Repository

    Le Maitre, Olivier

    2015-03-01

    A polynomial chaos (PC) analysis with stochastic expansion coefficients is proposed for stochastic differential equations driven by additive or multiplicative Wiener noise. It is shown that for this setting, a Galerkin formalism naturally leads to the definition of a hierarchy of stochastic differential equations governing the evolution of the PC modes. Under the mild assumption that the Wiener and uncertain parameters can be treated as independent random variables, it is also shown that the Galerkin formalism naturally separates parametric uncertainty and stochastic forcing dependences. This enables us to perform an orthogonal decomposition of the process variance, and consequently identify contributions arising from the uncertainty in parameters, the stochastic forcing, and a coupled term. Insight gained from this decomposition is illustrated in light of implementation to simplified linear and non-linear problems; the case of a stochastic bifurcation is also considered.

  9. A simple white noise analysis of neuronal light responses.

    Science.gov (United States)

    Chichilnisky, E J

    2001-05-01

    A white noise technique is presented for estimating the response properties of spiking visual system neurons. The technique is simple, robust, efficient and well suited to simultaneous recordings from multiple neurons. It provides a complete and easily interpretable model of light responses even for neurons that display a common form of response nonlinearity that precludes classical linear systems analysis. A theoretical justification of the technique is presented that relies only on elementary linear algebra and statistics. Implementation is described with examples. The technique and the underlying model of neural responses are validated using recordings from retinal ganglion cells, and in principle are applicable to other neurons. Advantages and disadvantages of the technique relative to classical approaches are discussed.

  10. A Comparison of seismic instrument noise coherence analysis techniques

    Science.gov (United States)

    Ringler, A.T.; Hutt, C.R.; Evans, J.R.; Sandoval, L.D.

    2011-01-01

    The self-noise of a seismic instrument is a fundamental characteristic used to evaluate the quality of the instrument. It is important to be able to measure this self-noise robustly, to understand how differences among test configurations affect the tests, and to understand how different processing techniques and isolation methods (from nonseismic sources) can contribute to differences in results. We compare two popular coherence methods used for calculating incoherent noise, which is widely used as an estimate of instrument self-noise (incoherent noise and self-noise are not strictly identical but in observatory practice are approximately equivalent; Holcomb, 1989; Sleeman et al., 2006). Beyond directly comparing these two coherence methods on similar models of seismometers, we compare how small changes in test conditions can contribute to incoherent-noise estimates. These conditions include timing errors, signal-to-noise ratio changes (ratios between background noise and instrument incoherent noise), relative sensor locations, misalignment errors, processing techniques, and different configurations of sensor types.

  11. Seismic Background Noise Analysis of BRTR (PS-43) Array

    Science.gov (United States)

    Ezgi Bakir, Mahmure; Meral Ozel, Nurcan; Umut Semin, Korhan

    2015-04-01

    The seismic background noise variation of BRTR array, composed of two sub arrays located in Ankara and in Ankara-Keskin, has been investigated by calculating Power Spectral Density and Probability Density Functions for seasonal and diurnal noise variations between 2005 and 2011. PSDs were computed within the frequency range of 100 s - 10 Hz. The results show us a little change in noise conditions in terms of time and location. Especially, noise level changes were observed at 3-5 Hz in diurnal variations at Keskin array and there is a 5-7 dB difference in day and night time in cultural noise band (1-10 Hz). On the other hand, noise levels of medium period array is high in 1-2 Hz frequency rather than short period array. High noise levels were observed in daily working times when we compare it to night-time in cultural noise band. The seasonal background noise variation at both sites also shows very similar properties to each other. Since these stations are borehole instruments and away from the coasts, we saw a small change in noise levels caused by microseism. Comparison between Keskin short period array and Ankara medium period array show us Keskin array is quiter than Ankara array.

  12. Multi-scale analysis of teleconnection indices: climate noise and nonlinear trend analysis

    Directory of Open Access Journals (Sweden)

    C. Franzke

    2009-02-01

    Full Text Available The multi-scale nature and climate noise properties of teleconnection indices are examined by using the Empirical Mode Decomposition (EMD procedure. The EMD procedure allows for the analysis of non-stationary time series to extract physically meaningful intrinsic mode functions (IMF and nonlinear trends. The climatologically relevant monthly mean teleconnection indices of the North Atlantic Oscillation (NAO, the North Pacific index (NP and the Southern Annular Mode (SAM are analyzed.

    The significance of IMFs and trends are tested against the null hypothesis of climate noise. The analysis of surrogate monthly mean time series from a red noise process shows that the EMD procedure is effectively a dyadic filter bank and the IMFs (except the first IMF are nearly Gaussian distributed. The distribution of the variance contained in IMFs of an ensemble of AR(1 simulations is nearly χ2 distributed. To test the statistical significance of the IMFs of the teleconnection indices and their nonlinear trends we utilize an ensemble of corresponding monthly averaged AR(1 processes, which we refer to as climate noise. Our results indicate that most of the interannual and decadal variability of the analysed teleconnection indices cannot be distinguished from climate noise. The NP and SAM indices have significant nonlinear trends, while the NAO has no significant trend when tested against a climate noise hypothesis.

  13. Road Traffic Noise Pollution Analysis for Cernavoda City

    Science.gov (United States)

    Manea, L.; Manea, A.; Florea, D.; Tarulescu, S.

    2017-10-01

    In the present paper was studied the noise pollution in Cernavodă city. The noise measurements were made for nine intersections from different city areas. Noise measurements were taken for three chosen routes with high population density, heavy traffic, commercial and residential buildings. Average, maximum and minimum values were collected and compared with standards. The impact of road traffic noise on the community depends on various factors such as road location and design, land use planning measures, building design, traffic composition, driver behaviour and the relief. In the study area 9 locations are identified to measure noise level. By using sound level meter noise levels are measured at different peak sessions i.e. morning, afternoon and evening. The presented values were collected for evening rush hour.

  14. Lability of nanoparticulate metal complexes in electrochemical speciation analysis

    DEFF Research Database (Denmark)

    van Leeuwen, Herman P.; Town, Raewyn M.

    2016-01-01

    Lability concepts are elaborated for metal complexes with soft (3D) and hard (2D) aqueous nanoparticles. In the presence of a non-equilibrium sensor, e.g. a voltammetric electrode, the notion of lability for nanoparticulate metal complexes, M-NP, reflects the ability of the M-NP to maintain...... equilibrium with the reduced concentration of the electroactive free M2+ in its diffusion layer. Since the metal ion binding sites are confined to the NP body, the conventional reaction layer in the form of a layer adjacent to the electrode surface is immaterial. Instead an intraparticulate reaction zone may...... of the electrochemical technique is crucial in the lability towards the electrode surface. In contrast, for nanoparticulate complexes it is the dynamics of the exchange of the electroactive metal ion with the surrounding medium that governs the effective lability towards the electrode surface....

  15. Measurement and analysis of self-noise in hybrid-driven underwater gliders

    Directory of Open Access Journals (Sweden)

    LIU Lu

    2017-08-01

    Full Text Available The Hybrid-driven Underwater Glider (HUG is a new type of submersible vehicle which combines the functions of traditional Autonomous Underwater Vehicles(AUVand Autonomous Underwater Gliders(AUG. In order to study its noise source distribution and basic self-noise characteristics, a self-noise acquisition system based on the HUG was designed and developed, and a noise analysis test carried out in a free-field pool. In August 2016, the sea trial of the Petrel II glider was conducted in the South China Sea, with observation data at a depth range of 1 000 m as the research object. The self-noise data of the glider platform under different working conditions was obtained through the step-by-step operation method. The experimental analysis and results show that the self-noise acquisition system is stable. The contribution of mechanical noise to self-noise is greatest when the glider works in the gliding mode, while the self-noise band above 500 Hz is closely related to the work of the buoyancy adjustment unit, and peaks at 1 kHz. According to the analysis of the basic characteristics of self-noise, this provides some guidance for the implementation of vibration and noise reduction.

  16. Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

    Science.gov (United States)

    Economou, Anastasios

    2018-03-29

    This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of "green" metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  17. Analysis of the Noise Characteristics of CMOS Current Conveyors

    DEFF Research Database (Denmark)

    Bruun, Erik

    1997-01-01

    The definition of the current conveyor is reviewed and a multiple-output second generation current conveyor (CCII) is shown to combine the different generations of current conveyors presently existing. Next, noise sources are introduced, and a general noise model for the current conveyor is descr......The definition of the current conveyor is reviewed and a multiple-output second generation current conveyor (CCII) is shown to combine the different generations of current conveyors presently existing. Next, noise sources are introduced, and a general noise model for the current conveyor...

  18. Noise analysis of the Dodewaard boiling water reactor: characteristics and time history

    International Nuclear Information System (INIS)

    Veer, J.H.C. v.d.; Kema, N.V.

    1982-01-01

    Reactor noise measurements have been performed in the Dodewaard BWR since the eighth fuel cycle (1978). Analysis of the noise characteristics of the ex-core neutron detectors are reported. As a result characteristics of the global component of the boiling noise and the influence of oscillatory effects in reactor pressure control and steam flow rate are described. The influence of power feedback effects on the detection of global noise at low frequencies is given using point kinetic reactor theory. Results are reported on the behaviour of the neutron noise characteristics during one fuel cycle and on the behaviour from fuel cycle 8 to 11. (author)

  19. Principal component analysis of 1/fα noise

    International Nuclear Information System (INIS)

    Gao, J.B.; Cao Yinhe; Lee, J.-M.

    2003-01-01

    Principal component analysis (PCA) is a popular data analysis method. One of the motivations for using PCA in practice is to reduce the dimension of the original data by projecting the raw data onto a few dominant eigenvectors with large variance (energy). Due to the ubiquity of 1/f α noise in science and engineering, in this Letter we study the prototypical stochastic model for 1/f α processes--the fractional Brownian motion (fBm) processes using PCA, and find that the eigenvalues from PCA of fBm processes follow a power-law, with the exponent being the key parameter defining the fBm processes. We also study random-walk-type processes constructed from DNA sequences, and find that the eigenvalue spectrum from PCA of those random-walk processes also follow power-law relations, with the exponent characterizing the correlation structures of the DNA sequence. In fact, it is observed that PCA can automatically remove linear trends induced by patchiness in the DNA sequence, hence, PCA has a similar capability to the detrended fluctuation analysis. Implications of the power-law distributed eigenvalue spectrum are discussed

  20. Electrochemical Impedance Spectroscopic Analysis of RuO2 Based Thick Film pH Sensors

    International Nuclear Information System (INIS)

    Manjakkal, Libu; Djurdjic, Elvira; Cvejin, Katarina; Kulawik, Jan; Zaraska, Krzysztof; Szwagierczak, Dorota

    2015-01-01

    The conductimetric interdigitated thick film pH sensors based on RuO 2 were fabricated and their electrochemical reactions with solutions of different pH values were studied by electrochemical impedance spectroscopy (EIS) technique. The microstructural properties and composition of the sensitive films were examined by scanning electron microscopy, X-ray energy dispersive spectroscopy and Raman spectroscopy. The EIS analysis of the sensor was carried out in the frequency range 10 mHz–2 MHz for pH values of test solutions 2–12. The electrical parameters of the sensor were found to vary with changing pH. The conductance and capacitance of the film were distinctly dependent on pH in the low frequency range. The Nyquist and Bode plots derived from the impedance data for the metal oxide thick film pH sensor provided information about the underlying electrochemical reactions

  1. Numerical noise analysis for insulator of overhead transmission line

    Science.gov (United States)

    Zhang, Yulin; Chen, Yuwen; Huang, Yu

    2018-04-01

    As an important and complex issue in aero acoustic field, a lot of explorations have been devoted to the wind-induced noise. However, there is still lack of intensive investigations for aerodynamic noise in high-voltage transmission. The overhead transmission line system leads to serious occupational noise exposure in high wind-speed environment, and the noise can even injure the electricians in charge of insulator. By using computational fluid dynamics (CFD) which combined with computational aero acoustics (CAA), this paper predicts the noise generated by insulator of high voltage electricity transmission line which explores in wind environment. The simulation results indicate that the wind velocity, the assembly angle of the insulator and its ribs' distribution are the main contributory factors for the aerodynamic noise. Specifically, when wind velocity is greater than 15m/s, the alteration of noise is not sensitive to the wind velocity; furthermore, when the assembly angle increases from 0°to 60°, the noise decreases gradually, however, if the angle is happening to be 75°or 90°, it would be even greater than that at 0°. In order to inhibit the aerodynamic noise, it is necessary to control the flow blowing across the boundary of the insulator. Consequently, the result indicates that if the outermost rib is shorter than the second one, the noise reduced evidently. This information expects to provide useful help for the extremely suppression of aerodynamic noise, and also supply practical reference material for the design and application of overhead transmission line system.

  2. Modelling of passive films: complementarity and applicability to the electrochemical impedance spectroscopy analysis

    International Nuclear Information System (INIS)

    Boissy, Clement; Normand, Bernard

    2013-01-01

    A review of the published models to describe the passivation of metallic materials is proposed. The objective is to illustrate the importance of the selection of a model considering their complementarity. The discussion is based on an analysis to assess whether the mass transport in the film must be taken into account or not in the modelling of the electrochemical impedance. (authors)

  3. Analysis and removing noise from speech using wavelet transform

    Science.gov (United States)

    Tomala, Karel; Voznak, Miroslav; Partila, Pavol; Rezac, Filip; Safarik, Jakub

    2013-05-01

    The paper discusses the use of Discrete Wavelet Transform (DWT) and Stationary Wavelet Transform (SWT) wavelet in removing noise from voice samples and evaluation of its impact on speech quality. One significant part of Quality of Service (QoS) in communication technology is the speech quality assessment. However, this part is seriously overlooked as telecommunication providers often focus on increasing network capacity, expansion of services offered and their enforcement in the market. Among the fundamental factors affecting the transmission properties of the communication chain is noise, either at the transmitter or the receiver side. A wavelet transform (WT) is a modern tool for signal processing. One of the most significant areas in which wavelet transforms are used is applications designed to suppress noise in signals. To remove noise from the voice sample in our experiment, we used the reference segment of the voice which was distorted by Gaussian white noise. An evaluation of the impact on speech quality was carried out by an intrusive objective algorithm Perceptual Evaluation of Speech Quality (PESQ). DWT and SWT transformation was applied to voice samples that were devalued by Gaussian white noise. Afterwards, we determined the effectiveness of DWT and SWT by means of objective algorithm PESQ. The decisive criterion for determining the quality of a voice sample once the noise had been removed was Mean Opinion Score (MOS) which we obtained in PESQ. The contribution of this work lies in the evaluation of efficiency of wavelet transformation to suppress noise in voice samples.

  4. Analysis of Individual Preferences for Tuning Noise-Reduction Algorithms

    NARCIS (Netherlands)

    Houben, Rolph; Dijkstra, Tjeerd M. H.; Dreschler, Wouter A.

    2012-01-01

    There is little research on user preference for different settings of noise reduction, especially for individual users. We therefore measured individual preferences for pairs of audio streams differing in the trade-off between noise reduction and speech distortion. A logistic probability model was

  5. Temporal Noise Analysis of Charge-Domain Sampling Readout Circuits for CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Xiaoliang Ge

    2018-02-01

    Full Text Available This paper presents a temporal noise analysis of charge-domain sampling readout circuits for Complementary Metal-Oxide Semiconductor (CMOS image sensors. In order to address the trade-off between the low input-referred noise and high dynamic range, a Gm-cell-based pixel together with a charge-domain correlated-double sampling (CDS technique has been proposed to provide a way to efficiently embed a tunable conversion gain along the read-out path. Such readout topology, however, operates in a non-stationery large-signal behavior, and the statistical properties of its temporal noise are a function of time. Conventional noise analysis methods for CMOS image sensors are based on steady-state signal models, and therefore cannot be readily applied for Gm-cell-based pixels. In this paper, we develop analysis models for both thermal noise and flicker noise in Gm-cell-based pixels by employing the time-domain linear analysis approach and the non-stationary noise analysis theory, which help to quantitatively evaluate the temporal noise characteristic of Gm-cell-based pixels. Both models were numerically computed in MATLAB using design parameters of a prototype chip, and compared with both simulation and experimental results. The good agreement between the theoretical and measurement results verifies the effectiveness of the proposed noise analysis models.

  6. Review of noise in neonatal intensive care units - regional analysis

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Abril, A [National Technological University, Regional Bioengineering Institute, Mendoza (Argentina); Terron, A; Boschi, C [National Technological University, Regional Bioengineering Institute, Mendoza (Argentina); Gomez, M [National Technological University, La Rioja (Argentina)

    2007-11-15

    This work is about the problem of noise in neonatal incubators and in the environment in the neonatal intensive care units. Its main objective is to analyse the impact of noise in hospitals of Mendoza and La Rioja. Methodology: The measures were taken in different moments in front of higher or lower severity level in the working environment. It is shown that noise produces severe damages and changes in the behaviour and the psychological status of the new born babies. Results: The noise recorded inside the incubators and the neonatal intensive care units together have many components but the noise of motors, opening and closing of access gates have been considered the most important ones. Values above 60 db and and up to 120 db in some cases were recorded, so the need to train the health staff in order to manage the new born babies, the equipment and the instruments associated with them very carefully is revealed.

  7. Review of noise in neonatal intensive care units - regional analysis

    International Nuclear Information System (INIS)

    Alvarez Abril, A; Terron, A; Boschi, C; Gomez, M

    2007-01-01

    This work is about the problem of noise in neonatal incubators and in the environment in the neonatal intensive care units. Its main objective is to analyse the impact of noise in hospitals of Mendoza and La Rioja. Methodology: The measures were taken in different moments in front of higher or lower severity level in the working environment. It is shown that noise produces severe damages and changes in the behaviour and the psychological status of the new born babies. Results: The noise recorded inside the incubators and the neonatal intensive care units together have many components but the noise of motors, opening and closing of access gates have been considered the most important ones. Values above 60 db and and up to 120 db in some cases were recorded, so the need to train the health staff in order to manage the new born babies, the equipment and the instruments associated with them very carefully is revealed

  8. Toward the detection of gravitational waves under non-Gaussian noises II. Independent component analysis.

    Science.gov (United States)

    Morisaki, Soichiro; Yokoyama, Jun'ichi; Eda, Kazunari; Itoh, Yousuke

    2016-01-01

    We introduce a new analysis method to deal with stationary non-Gaussian noises in gravitational wave detectors in terms of the independent component analysis. First, we consider the simplest case where the detector outputs are linear combinations of the inputs, consisting of signals and various noises, and show that this method may be helpful to increase the signal-to-noise ratio. Next, we take into account the time delay between the inputs and the outputs. Finally, we extend our method to nonlinearly correlated noises and show that our method can identify the coupling coefficients and remove non-Gaussian noises. Although we focus on gravitational wave data analysis, our methods are applicable to the detection of any signals under non-Gaussian noises.

  9. Partial and Total Annoyance Due to Road Traffic Noise Combined with Aircraft or Railway Noise: Structural Equation Analysis

    OpenAIRE

    Gille, Laure-Anne; Marquis-Favre, Catherine; Lam, Kin-Che

    2017-01-01

    Structural equation modeling was used to analyze partial and total in situ annoyance in combined transportation noise situations. A psychophysical total annoyance model and a perceptual total annoyance model were proposed. Results show a high contribution of Noise exposure and Noise sensitivity to Noise annoyance, as well as a causal relationship between noise annoyance and lower Dwelling satisfaction. Moreover, the Visibility of noise source may increase noise annoyance, even when the visibl...

  10. An analysis of low frequency noise from large wind turbines

    DEFF Research Database (Denmark)

    Pedersen, Christian Sejer; Møller, Henrik

    2010-01-01

    As wind turbines get larger, worries have emerged, that the noise emitted by the turbines would move down in frequency, and that the contents of low-frequency noise would be enough to cause significant annoyance for the neighbors. The sound emission from 48 wind turbines with nominal electric power......-third-octave-band spectra shows that the relative noise emission is higher in the 63-250 Hz frequency range from turbines above 2 MW than from smaller turbines. The observations confirm a downward shift of the spectrum....

  11. Noise characteristics analysis of short wave infrared InGaAs focal plane arrays

    Science.gov (United States)

    Yu, Chunlei; Li, Xue; Yang, Bo; Huang, Songlei; Shao, Xiumei; Zhang, Yaguang; Gong, Haimei

    2017-09-01

    The increasing application of InGaAs short wave infrared (SWIR) focal plane arrays (FPAs) in low light level imaging requires ultra-low noise FPAs. This paper presents the theoretical analysis of FPA noise, and point out that both dark current and detector capacitance strongly affect the FPA noise. The impact of dark current and detector capacitance on FPA noise is compared in different situations. In order to obtain low noise performance FPAs, the demand for reducing detector capacitance is higher especially when pixel pitch is smaller, integration time is shorter, and integration capacitance is larger. Several InGaAs FPAs were measured and analyzed, the experiments' results could be well fitted to the calculated results. The study found that the major contributor of FPA noise is coupled noise with shorter integration time. The influence of detector capacitance on FPA noise is more significant than that of dark current. To investigate the effect of detector performance on FPA noise, two kinds of photodiodes with different concentration of the absorption layer were fabricated. The detectors' performance and noise characteristics were measured and analyzed, the results are consistent with that of theoretical analysis.

  12. Realistic Noise Assessment and Strain Analysis of Iranian Permanent GPS Stations

    Science.gov (United States)

    Razeghi, S. M.; Amiri Simkooei, A. A.; Sharifi, M. A.

    2012-04-01

    To assess noise characteristics of Iranian Permanent GPS Stations (IPGS), northwestern part of this network namely Azerbaijan Continuous GPS Station (ACGS), was selected. For a realistic noise assessment it is required to model all deterministic signals of the GPS time series by means of least squares harmonic estimation (LS-HE) and derive all periodic behavior of the series. After taking all deterministic signals into account, the least squares variance component estimation (LS-VCE) is used to obtain a realistic noise model (white noise plus flicker noise) of the ACGS. For this purpose, one needs simultaneous GPS time series for which a multivariate noise assessment is applied. Having determined realistic noise model, a realistic strain analysis of the network is obtained for which one relies on the finite element methods. Finite element is now considered to be a new functional model and the new stochastic model is given based on the multivariate noise assessment using LS-VCE. The deformation rates of the components along with their full covariance matries are input to the strain analysis. Further, the results are also provided using a pure white noise model. The normalized strains for these two models show that the strain parameters derived from a realistic noise model are less significant than those derived from the white model. This could be either due to the short time span of the time series used or due to the intrinsic behavior of the strain parameters in the ACGS. Longer time series are required to further elaborate this issue.

  13. Edge enhancement and noise suppression for infrared image based on feature analysis

    Science.gov (United States)

    Jiang, Meng

    2018-06-01

    Infrared images are often suffering from background noise, blurred edges, few details and low signal-to-noise ratios. To improve infrared image quality, it is essential to suppress noise and enhance edges simultaneously. To realize it in this paper, we propose a novel algorithm based on feature analysis in shearlet domain. Firstly, as one of multi-scale geometric analysis (MGA), we introduce the theory and superiority of shearlet transform. Secondly, after analyzing the defects of traditional thresholding technique to suppress noise, we propose a novel feature extraction distinguishing image structures from noise well and use it to improve the traditional thresholding technique. Thirdly, with computing the correlations between neighboring shearlet coefficients, the feature attribute maps identifying the weak detail and strong edges are completed to improve the generalized unsharped masking (GUM). At last, experiment results with infrared images captured in different scenes demonstrate that the proposed algorithm suppresses noise efficiently and enhances image edges adaptively.

  14. 252Cf-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; King, W.T.; Blakeman, E.D.

    1985-01-01

    The 252 Cf-source-driven neutron noise analysis method has been tested in a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor k/sub eff/ has been satisfactorily detemined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments oriented toward particular applications including dynamic experiments and the development of theoretical methods to predict the experimental observables

  15. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    OpenAIRE

    Anastasios Economou

    2018-01-01

    This work reviews the field of screen-printed electrodes (SPEs) modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have ...

  16. Neutron activation analysis of uranium by means of electrochemical etching of tracks in lawsan detectors

    International Nuclear Information System (INIS)

    Kim Son Chun; Chuburkov, Yu.T.; Zvara, I.I.

    1982-01-01

    The method of neutron activation analysis of uranium in natural and artificial materials using track lavsan detectors of fission fragments has been developed. The method of electrochemical etching (etching reagent NaOH) of fragment tracks in lavsan is improved. Using statistical method of experiment planning the equation, describing the dependence of diometer value of fission fragment tracks on parameters of etching process, is obtained. The analysis sensitivity is 10 - 7 g/g - 10 - 8 g/g

  17. Automatic physiological waveform processing for FMRI noise correction and analysis.

    Directory of Open Access Journals (Sweden)

    Daniel J Kelley

    2008-03-01

    Full Text Available Functional MRI resting state and connectivity studies of brain focus on neural fluctuations at low frequencies which share power with physiological fluctuations originating from lung and heart. Due to the lack of automated software to process physiological signals collected at high magnetic fields, a gap exists in the processing pathway between the acquisition of physiological data and its use in fMRI software for both physiological noise correction and functional analyses of brain activation and connectivity. To fill this gap, we developed an open source, physiological signal processing program, called PhysioNoise, in the python language. We tested its automated processing algorithms and dynamic signal visualization on resting monkey cardiac and respiratory waveforms. PhysioNoise consistently identifies physiological fluctuations for fMRI noise correction and also generates covariates for subsequent analyses of brain activation and connectivity.

  18. Noise Analysis of Single-Ended Input Differential Amplifier using Stochastic Differential Equation

    OpenAIRE

    Tarun Kumar Rawat; Abhirup Lahiri; Ashish Gupta

    2008-01-01

    In this paper, we analyze the effect of noise in a single- ended input differential amplifier working at high frequencies. Both extrinsic and intrinsic noise are analyzed using time domain method employing techniques from stochastic calculus. Stochastic differential equations are used to obtain autocorrelation functions of the output noise voltage and other solution statistics like mean and variance. The analysis leads to important design implications and suggests changes in the device parame...

  19. Yesterday's noise - today's signal

    International Nuclear Information System (INIS)

    Serdula, K.J.

    1978-01-01

    Plant performance can be improved by noise analysis. This paper describes noise characteristics, imposed noise and response functions, a case history of cost benefits derived from application of noise analysis techniques, areas for application of noise analysis techniques with special reference to the Gentilly-1 nuclear generating station, and the validity of noise measurement results. (E.C.B.)

  20. Microfabricated Electrochemical Cell-Based Biosensors for Analysis of Living Cells In Vitro

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2012-04-01

    Full Text Available Cellular biochemical parameters can be used to reveal the physiological and functional information of various cells. Due to demonstrated high accuracy and non-invasiveness, electrochemical detection methods have been used for cell-based investigation. When combined with improved biosensor design and advanced measurement systems, the on-line biochemical analysis of living cells in vitro has been applied for biological mechanism study, drug screening and even environmental monitoring. In recent decades, new types of miniaturized electrochemical biosensor are emerging with the development of microfabrication technology. This review aims to give an overview of the microfabricated electrochemical cell-based biosensors, such as microelectrode arrays (MEA, the electric cell-substrate impedance sensing (ECIS technique, and the light addressable potentiometric sensor (LAPS. The details in their working principles, measurement systems, and applications in cell monitoring are covered. Driven by the need for high throughput and multi-parameter detection proposed by biomedicine, the development trends of electrochemical cell-based biosensors are also introduced, including newly developed integrated biosensors, and the application of nanotechnology and microfluidic technology.

  1. Intensity of noise in the classroom and analysis of acoustic emissions in schoolchildren

    Directory of Open Access Journals (Sweden)

    Almeida Filho, Nelson de

    2012-01-01

    Full Text Available Introduction: Noise-induced hearing loss is a sensorineural hearing loss, usually bilateral, irreversible and progressive with time of exposure. As the noise made by children in school may be considered detrimental, the study looks of their occurrence in Taubaté's schools. Objective: To determine if students are exposed to noise intensity affecting the cochlea, define the profile of these schoolchildren, demonstrating the occurrence of changes in cochlear activity following exposure to noise in a day of class. Method: Study's way prospective transversal cross sectional cut with 28 elementary school students in the first half of 2009. Questionnaires for assessing preexisting cochlear damage . Evaluation of cochlear function by analysis of acoustic emissions evoked distortion product, made before the students come into class and immediately after the end of these. Measurement of noise inside the classrooms and recreation areas during the interval. Results: 57.1% accused some hearing loss in the examinations before class. By day's end, 04 girls and 03 boys had worsened in relation of the first examination. The noise reached levels higher than recommended at the three class rooms. The largest number of students with worsening, belong to the class room with higher noise level. The noise during the intervals is also excessive. Conclusions: The noise in this school is above the limit. 42.85% of students who had experienced worsening had school performance inadequate. 25% had worse after noise exposure in a school day.

  2. The effects of observational correlated noises on multifractal detrended fluctuation analysis

    Science.gov (United States)

    Gulich, Damián; Zunino, Luciano

    2012-08-01

    We have numerically investigated the effects that observational correlated noises have on the generalized Hurst exponents, h(q), estimated by using the multifractal generalization of detrended fluctuation analysis (MF-DFA). More precisely, artificially generated stochastic binomial multifractals with increased amount of colored noises were analyzed via MF-DFA. It has been recently shown that for moderate additions of white noise, the generalized Hurst exponents are significantly underestimated for qeffects of additive noise, short- term memory and periodic trends, Physica A 390 (2011) 2480-2490]. In this paper, we have found that h(q) with q≥2 are also affected when correlated noises are considered. This is due to the fact that the spurious correlations influence the scaling behaviors associated to large fluctuations. The results obtained are significant for practical situations, where noises with different correlations are inherently present.

  3. Noise Parameter Analysis of SiGe HBTs for Different Sizes in the Breakdown Region

    Directory of Open Access Journals (Sweden)

    Chie-In Lee

    2016-01-01

    Full Text Available Noise parameters of silicon germanium (SiGe heterojunction bipolar transistors (HBTs for different sizes are investigated in the breakdown region for the first time. When the emitter length of SiGe HBTs shortens, minimum noise figure at breakdown decreases. In addition, narrower emitter width also decreases noise figure of SiGe HBTs in the avalanche region. Reduction of noise performance for smaller emitter length and width of SiGe HBTs at breakdown resulted from the lower noise spectral density resulting from the breakdown mechanism. Good agreement between experimental and simulated noise performance at breakdown is achieved for different sized SiGe HBTs. The presented analysis can benefit the RF circuits operating in the breakdown region.

  4. Noise analysis of the measurement of group delay in Fourier white-light interferometric cross correlation

    International Nuclear Information System (INIS)

    Laude, Vincent

    2002-01-01

    The problem of noise analysis in measuring the group delay introduced by a dispersive optical element by use of white-light interferometric cross correlation is investigated. Two noise types, detection noise and position noise, are specifically analyzed. Detection noise is shown to be highly sensitive to the spectral content of the white-light source at the frequency considered and to the temporal acquisition window. Position noise, which arises from the finite accuracy of the measurement of the scanning mirror's position, can severely damage the estimation of the group delay. Such is shown to be the case for fast Fourier transform-based estimation algorithms. A new algorithm that is insensitive to scanning delay errors is proposed, and subfemtosecond accuracy is obtained without any postprocessing

  5. Fast noise level estimation algorithm based on principal component analysis transform and nonlinear rectification

    Science.gov (United States)

    Xu, Shaoping; Zeng, Xiaoxia; Jiang, Yinnan; Tang, Yiling

    2018-01-01

    We proposed a noniterative principal component analysis (PCA)-based noise level estimation (NLE) algorithm that addresses the problem of estimating the noise level with a two-step scheme. First, we randomly extracted a number of raw patches from a given noisy image and took the smallest eigenvalue of the covariance matrix of the raw patches as the preliminary estimation of the noise level. Next, the final estimation was directly obtained with a nonlinear mapping (rectification) function that was trained on some representative noisy images corrupted with different known noise levels. Compared with the state-of-art NLE algorithms, the experiment results show that the proposed NLE algorithm can reliably infer the noise level and has robust performance over a wide range of image contents and noise levels, showing a good compromise between speed and accuracy in general.

  6. On-line analysis of reactor noise using time-series analysis

    International Nuclear Information System (INIS)

    McGevna, V.G.

    1981-10-01

    A method to allow use of time series analysis for on-line noise analysis has been developed. On-line analysis of noise in nuclear power reactors has been limited primarily to spectral analysis and related frequency domain techniques. Time series analysis has many distinct advantages over spectral analysis in the automated processing of reactor noise. However, fitting an autoregressive-moving average (ARMA) model to time series data involves non-linear least squares estimation. Unless a high speed, general purpose computer is available, the calculations become too time consuming for on-line applications. To eliminate this problem, a special purpose algorithm was developed for fitting ARMA models. While it is based on a combination of steepest descent and Taylor series linearization, properties of the ARMA model are used so that the auto- and cross-correlation functions can be used to eliminate the need for estimating derivatives. The number of calculations, per iteration varies lineegardless of the mee 0.2% yield strength displayed anisotropy, with axial and circumferential values being greater than radial. For CF8-CPF8 and CF8M-CPF8M castings to meet current ASME Code S acid fuel cells

  7. Market Analysis of Soundproof and Noise Reduction Plate

    Directory of Open Access Journals (Sweden)

    Chang Heyu

    2017-01-01

    Full Text Available Since the reform and opening up, China has a booming economy development, transportation industry as an important part of the economic processes has made a considerable progress, and continue to promote the rapid economic development. At the end of 2012, China's highway mileage has reached 4.238 million km and highway mileage ranks first in the world. Transportation in promoting rapid economic development, but also brings the traffic noise which has a tremendous influence on residents’ daily life, and this influence has gradually deepening and widening, in this situation the production of noise reduction panel gradually emerged. In this paper, a noise barriers manufacturer’ business model in Beijing Daxing District and analyze existing data will be analyzed, it will give much guidance and reference for a new noise reduction factory. The study has shown that plant will target all levels of government departments in charge of roads and the property of management department of residence as our customer groups, increasing technological innovation and improving product quality to establish a more extensive business relationships, and gradually formed noise barriers market competitiveness.

  8. Simulation on a car interior aerodynamic noise control based on statistical energy analysis

    Science.gov (United States)

    Chen, Xin; Wang, Dengfeng; Ma, Zhengdong

    2012-09-01

    How to simulate interior aerodynamic noise accurately is an important question of a car interior noise reduction. The unsteady aerodynamic pressure on body surfaces is proved to be the key effect factor of car interior aerodynamic noise control in high frequency on high speed. In this paper, a detail statistical energy analysis (SEA) model is built. And the vibra-acoustic power inputs are loaded on the model for the valid result of car interior noise analysis. The model is the solid foundation for further optimization on car interior noise control. After the most sensitive subsystems for the power contribution to car interior noise are pointed by SEA comprehensive analysis, the sound pressure level of car interior aerodynamic noise can be reduced by improving their sound and damping characteristics. The further vehicle testing results show that it is available to improve the interior acoustic performance by using detailed SEA model, which comprised by more than 80 subsystems, with the unsteady aerodynamic pressure calculation on body surfaces and the materials improvement of sound/damping properties. It is able to acquire more than 2 dB reduction on the central frequency in the spectrum over 800 Hz. The proposed optimization method can be looked as a reference of car interior aerodynamic noise control by the detail SEA model integrated unsteady computational fluid dynamics (CFD) and sensitivity analysis of acoustic contribution.

  9. Cascaded analysis of signal and noise propagation through a heterogeneous breast model

    International Nuclear Information System (INIS)

    Mainprize, James G.; Yaffe, Martin J.

    2010-01-01

    Purpose: The detectability of lesions in radiographic images can be impaired by patterns caused by the surrounding anatomic structures. The presence of such patterns is often referred to as anatomic noise. Others have previously extended signal and noise propagation theory to include variable background structure as an additional noise term and used in simulations for analysis by human and ideal observers. Here, the analytic forms of the signal and noise transfer are derived to obtain an exact expression for any input random distribution and the ''power law'' filter used to generate the texture of the tissue distribution. Methods: A cascaded analysis of propagation through a heterogeneous model is derived for x-ray projection through simulated heterogeneous backgrounds. This is achieved by considering transmission through the breast as a correlated amplification point process. The analytic forms of the cascaded analysis were compared to monoenergetic Monte Carlo simulations of x-ray propagation through power law structured backgrounds. Results: As expected, it was found that although the quantum noise power component scales linearly with the x-ray signal, the anatomic noise will scale with the square of the x-ray signal. There was a good agreement between results obtained using analytic expressions for the noise power and those from Monte Carlo simulations for different background textures, random input functions, and x-ray fluence. Conclusions: Analytic equations for the signal and noise properties of heterogeneous backgrounds were derived. These may be used in direct analysis or as a tool to validate simulations in evaluating detectability.

  10. An Analysis of FM Jamming and Noise Quality Measures

    Science.gov (United States)

    1993-12-01

    equipment setup is shown in figure 6. For reasons of practicality and manageability , all equipment was chosen to be commercially available and of a fairly...bins based on the size of the parameter F. It computes a smoothed "Turner Noise Qaulity " similar to the noise quality measure employed by Daly in his...recý.orate for :nf-,aton Doe,A-,ým5 1o- A c-t•s. )2 15 efferso Oarts H,9gPay, Srte 1204. ArtOngton, VA 222024302 and to the Of"ce of Management and aucige

  11. An electrochemical sensor based on carboxymethylated dextran modified gold surface for ochratoxin A analysis

    OpenAIRE

    Heurich, Meike; Kadir, Mohamad Kamal Abdul; Tothill, Ibtisam E.

    2011-01-01

    A disposable electrochemical immunosensor method was developed for ochratoxin A analysis to be applied for wine samples by using a screen-printed gold working electrode with carbon counter and silver/silver chloride pseudo-reference electrode. An indirect competitive enzyme-linked immunosorbent assay (ELISA) format was constructed by immobilising ochratoxin A conjugate using passive adsorption or covalent immobilisation via amine coupling to a carboxymethylated dextran (CMD)...

  12. RESULTS OF THE EXAMINATION OF ELECTROCHEMICAL NOISE PROBE SPECIMENS REMOVED FROM TANK 241-AN-107, JUNE, 2010

    International Nuclear Information System (INIS)

    Cooke, G.A.; Wyrwas, R.B.; Duncan, J.B.

    2010-01-01

    An Integrated Multi-function Corrosion Probe (IMCP) was installed in Tank 241-AN-107 on September 20, 2006. A portion of the probe was retrieved on June 8, 2010 and the sections holding the detectors were delivered to the 222-S Laboratory for analysis. The examination and disassembly of the probe sections encountered a number of challenges. However, disassembly and relevant analyses were successfully completed. The following summarizes our observations. Brittle failure of the fiberglass probe in the middle of detector 2 resulted in the recovery of only three vapor space C-rings and six supernatant bullet specimens. The design of the bullets and how they were attached to the probe made the recovery of the components more difficult. The use of glue/epoxy on the bullets and the attachment of the flat bottom of the bullets to the curved surface of the fiberglass probe body meant that weight loss on cleaning and surface area of the specimens could not be determined with acceptable accuracy. Macrophotography of all specimens reveals that corrosion was slight in the vapor space and extremely slight in the supernatant. The one pre-cracked C-ring recovered from the vapor space still had the stress bulge visible on the polished surface, indicating that crack propagation had not occurred in the tank. No photographs were taken of the C-ring before deployment. No further analysis was conducted on this specimen. A detailed discussion and photographic documentation are provided in this report.

  13. Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography.

    Science.gov (United States)

    Waugh, William; Allen, John; Wightman, James; Sims, Andrew J; Beale, Thomas A W

    2018-01-01

    Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals.

  14. Advances in noise analysis for nuclear plant surveillance and diagnostics

    International Nuclear Information System (INIS)

    Fry, N.; Clapp, N.E. Jr.; Sides, W.H. Jr.; Mihalczo, J.T.; King, W.T.

    1980-01-01

    An automated surveillance and baseline noise signature acquisition system is being demonstrated at Sequoyah-1. A nonperturbing method is also being developed for monitoring the subcritical reactivity during initial core loading in LWRs, in fuel storage and processing facilities, and during postaccident recovery operations such as Three Mile Island-2

  15. Coolant flow monitoring in a PWR core using noise analysis

    International Nuclear Information System (INIS)

    Kostic, Lj.

    1992-01-01

    Experimental investigations of the neutron and temperature noise field have been performed in the 1350 MW PWR nuclear power plant. Evaluation in the low frequency range, where both feedback effects and different thermohydraulics phenomena are dominant, succeeded in measuring the coolant velocity. This is important for determination and localization of essential deviations and possible anomalies. (author)

  16. SMORN-III benchmark test on reactor noise analysis methods

    International Nuclear Information System (INIS)

    Shinohara, Yoshikuni; Hirota, Jitsuya

    1984-02-01

    A computational benchmark test was performed in conjunction with the Third Specialists Meeting on Reactor Noise (SMORN-III) which was held in Tokyo, Japan in October 1981. This report summarizes the results of the test as well as the works made for preparation of the test. (author)

  17. Analysis of Femtosecond Timing Noise and Stability in Microwave Components

    International Nuclear Information System (INIS)

    2011-01-01

    To probe chemical dynamics, X-ray pump-probe experiments trigger a change in a sample with an optical laser pulse, followed by an X-ray probe. At the Linac Coherent Light Source, LCLS, timing differences between the optical pulse and x-ray probe have been observed with an accuracy as low as 50 femtoseconds. This sets a lower bound on the number of frames one can arrange over a time scale to recreate a 'movie' of the chemical reaction. The timing system is based on phase measurements from signals corresponding to the two laser pulses; these measurements are done by using a double-balanced mixer for detection. To increase the accuracy of the system, this paper studies parameters affecting phase detection systems based on mixers, such as signal input power, noise levels, temperature drift, and the effect these parameters have on components such as the mixers, splitters, amplifiers, and phase shifters. Noise data taken with a spectrum analyzer show that splitters based on ferrite cores perform with less noise than strip-line splitters. The data also shows that noise in specific mixers does not correspond with the changes in sensitivity per input power level. Temperature drift is seen to exist on a scale between 1 and 27 fs/ o C for all of the components tested. Results show that any components using more metallic conductor tend to exhibit more noise as well as more temperature drift. The scale of these effects is large enough that specific care should be given when choosing components and designing the housing of high precision microwave mixing systems for use in detection systems such as the LCLS. With these improvements, the timing accuracy can be improved to lower than currently possible.

  18. Analysis and suppression of passive noise in surface microseismic data

    Science.gov (United States)

    Forghani-Arani, Farnoush

    Surface microseismic surveys are gaining popularity in monitoring the hydraulic fracturing process. The effectiveness of these surveys, however, is strongly dependent on the signal-to-noise ratio of the acquired data. Cultural and industrial noise generated during hydraulic fracturing operations usually dominate the data, thereby decreasing the effectiveness of using these data in identifying and locating microseismic events. Hence, noise suppression is a critical step in surface microseismic monitoring. In this thesis, I focus on two important aspects in using surface-recorded microseismic seismic data: first, I take advantage of the unwanted surface noise to understand the characteristics of these noise and extract information about the propagation medium from the noise; second, I propose effective techniques to suppress the surface noise while preserving the waveforms that contain information about the source of microseisms. Automated event identification on passive seismic data using only a few receivers is challenging especially when the record lengths span over long durations of time. I introduce an automatic event identification algorithm that is designed specifically for detecting events in passive data acquired with a small number of receivers. I demonstrate that the conventional STA/LTA (Short-term Average/Long-term Average) algorithm is not sufficiently effective in event detection in the common case of low signal-to-noise ratio. With a cross-correlation based method as an extension of the STA/LTA algorithm, even low signal-to-noise events (that were not detectable with conventional STA/LTA) were revealed. Surface microseismic data contains surface-waves (generated primarily from hydraulic fracturing activities) and body-waves in the form of microseismic events. It is challenging to analyze the surface-waves on the recorded data directly because of the randomness of their source and their unknown source signatures. I use seismic interferometry to extract

  19. Development and applications of reactor noise analysis at Ontario Hydro's CANDU reactors

    International Nuclear Information System (INIS)

    Gloeckler, O.; Tulett, M.V.

    1995-01-01

    In 1992 a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro's CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. The dynamic characteristics of critical plant components, instrumentation and processes are monitored on a regular basis. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes induced by moderator flow, (6) estimating the dynamics and response time of RTD (Resistance Temperature Detector) temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (10) detecting coolant boiling in fully instrumented fuel channels, (11) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as-needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology. (author

  20. Development and applications of reactor noise analysis at Ontario Hydro`s CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, O [Ontario Hydro, Toronto, ON (Canada); Tulett, M V [Ontario Hydro, Pickering, ON (Canada). Pickering Generating Station

    1996-12-31

    In 1992 a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro`s CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. The dynamic characteristics of critical plant components, instrumentation and processes are monitored on a regular basis. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes induced by moderator flow, (6) estimating the dynamics and response time of RTD (Resistance Temperature Detector) temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (10) detecting coolant boiling in fully instrumented fuel channels, (11) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as-needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology. (author

  1. Electrochemical Characterization and Degradation Analysis of Large SOFC Stacks by Impedance Spectroscopy

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Hjelm, Johan; Barfod, R.

    2013-01-01

    As solid oxide fuel cell (SOFC) technology is moving closer to a commercial break through, lifetime limiting factors, and methods to measure the “state-of-health” of operating cells and stacks are becoming of increasing interest. This requires application of advanced methods for detailed...... electrochemical characterization during operation. An experimental stack with low ohmic resistance from Topsoe Fuel Cell A/S was characterized in detail using electrochemical impedance spectroscopy (EIS). An investigation of the optimal geometrical placement of the current feeds and voltage probes was carried out...... with hydrogen as fuel with 52% fuel utilization and constant current load (0.2 A cm–2) at 750 °C. Stack interconnects were coated with six different coatings to prevent chromium poisoning on the cathode side. Four repeating units (RUs) with different coatings were selected for detailed impedance analysis. EIS...

  2. Recent progress in safety-related applications of reactor noise analysis

    International Nuclear Information System (INIS)

    Hirota, Jitsuya; Shinohara, Yoshikuni; Saito, Keiichi

    1982-01-01

    Recent progress in safety-related applications of reactor noise analysis is reviewed, mainly referring to various papers presented at the Third Specialists' Meeting on Reactor Noise (SMORN-III) held in Tokyo in 1981. Advances in application of autoregressive model, coherence analysis and pattern recognition technique are significant since SMORN-II in 1977. Development of reactor diagnosis systems based on noise analysis is in progress. Practical experiences in the safety-related applications to power plants are being accumulated. Advances in quantitative monitoring of vibration of internal structures in PWR and diagnosis of core stability and control system characteristics in BWR are notable. Acoustic methods are also improved to detect sodium boiling in LMFBR. The Reactor Noise Analysis Benchmark Test performed by Japan in connection with SMORN-III is successful so that it is possible to proceed to the second stage of the benchmark test. (author)

  3. Possibilities to employ noise analysis techniques in controlling nuclear power stations

    International Nuclear Information System (INIS)

    Alfonso Pallares, C.; Iglesias Ferrer, R.; Sarabia Molina, I.

    1998-01-01

    This work shows basic requirements the authors think must be complied with by monitoring systems for operational surveillance based on noise analysis techniques that in turn can be employed in the regulatory control

  4. The nonlinear treatment in noise analysis and its influence into quality programs

    International Nuclear Information System (INIS)

    Montesino, Maria Elena; Piedra, Margarita; Rolo, Alberto

    2002-01-01

    Analysis by noise technique have been utilized in fact for early detection reactor's anomalies, constituting one of the fundamental tools in maintenance condition. There is an international tendency to use this technique in order to guarantee the quality of maintenance control at present. Essentially this technique is an approach from lineal dynamic and insufficient for limit cycle illustrations, which take place after bifurcation point. As non-lineal dynamic (chaos theory) descriptors consider the dynamic characteristics of studied system, their uses guarantee the quality in predictive maintenance by noise. In this paper was analysed the necessity of theory's use as a tool to supplement the analysis by noise technique. (author)

  5. Application of noise analysis to investigate core degradation process during PHEBUS-FPT1 test

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1997-01-01

    Noise analysis has been performed for measurement data obtained during PHEBUS-FPT1 test. The purpose of the study is to evaluate the applicability of the noise analysis to the following problems: To get more knowledge about the physical processes going on during severe core conditions; To better understand the core melting process; To establish appropriate on-line shut-down data. Results of the study indicate that the noise analysis is quite promising as a tool for investigating physical processes during the experiment. Compared with conventional approach of evaluating the signal's mean value behaviour, the noise analysis can provide additional, more detailed information: It was found that the neutron flux signal is subjected to additional reactivity perturbations in conjunction with fuel melting and relocation. This can easily be detected by applying noise analysis for the neutron flux signal. It has been demonstrated that the method developed in the present study can provide more accurate estimates of the onset of fuel relocation than using temperature signals from thermocouples in the thermal shroud. Moreover, the result suggests a potential of the present method for tracking the whole process of relocation. The result of the data analysis suggests a possibility of sensor diagnostics which may be important for confirming the quality and reliability of the recorded data. Based on the results achieved it is believed that the combined use of noise analysis and thermocouple signals will provide reliable shut-down criteria for the experiment. 8 refs

  6. Monitoring and diagnosis in situ: noise analysis; Vigilancia y diagnostico in situ analisis de ruido

    Energy Technology Data Exchange (ETDEWEB)

    Montalvo, C.; Garcia-Berrocal, A.

    2014-04-01

    Predictive maintenance based on surveillance and breakdowns diagnostics can be achieved through the analysis of the noise hidden in the signals. At the beginning noise analysis was development to monitor the power signals coming from neutron detectors. Nowadays its applications are very diverse. For instance: process sensors surveillance such us Resistance Temperature detectors, thermocouples and pressure transmitters, internals vibration monitoring, abnormal vibrations detection, etc. In this work some examples from the literature and from the authors experience are presented. (Author)

  7. Experience with a PC-based system for noise and DC signal analysis in PWRs

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1996-01-01

    A data acquisition system that was originally developed for noise diagnostics in PWRs was expanded to include DC signal analysis in addition to noise analysis. The system has been used in PWRs for reactor diagnostics, determination of root cause of process anomalies, instrument calibration verification, measurement of drop time of control and shutdown rods, testing of timing and sequencing of control rod drive mechanisms, emergency diesel generator monitoring, etc. These applications are reviewed in this paper. (author)

  8. Theoretical analysis of quantum dot amplifiers with high saturation power and low noise figure

    DEFF Research Database (Denmark)

    Berg, Tommy Winther; Mørk, Jesper

    2002-01-01

    Semiconductor quantum dot amplifiers are predicted to exhibit superior characteristics such as high gain, and output power and low noise. The analysis provides criteria and design guidelines for the realization of high quality amplifiers.......Semiconductor quantum dot amplifiers are predicted to exhibit superior characteristics such as high gain, and output power and low noise. The analysis provides criteria and design guidelines for the realization of high quality amplifiers....

  9. On minimizing the influence of the noise tail of correlation functions in operational modal analysis

    DEFF Research Database (Denmark)

    Tarpø, Marius; Olsen, Peter; Amador, Sandro

    2017-01-01

    on the identification results (random errors) when the noise tail is included in the identification. On the other hand, if the correlation function is truncated too much, then important information is lost. In other to minimize this error, a suitable truncation based on manual inspection of the correlation function......In operational modal analysis (OMA) correlation functions are used by all classical time-domain modal identification techniques that uses the impulse response function (free decays) as primary data. However, the main difference between the impulse response and the correlation functions estimated...... from the operational responses is that the latter present a higher noise level. This is due to statistical errors in the estimation of the correlation function and it causes random noise in the end of the function and this is called the noise tail. This noise might have significant influence...

  10. Analysis and Extension of the PCA Method, Estimating a Noise Curve from a Single Image

    Directory of Open Access Journals (Sweden)

    Miguel Colom

    2016-12-01

    Full Text Available In the article 'Image Noise Level Estimation by Principal Component Analysis', S. Pyatykh, J. Hesser, and L. Zheng propose a new method to estimate the variance of the noise in an image from the eigenvalues of the covariance matrix of the overlapping blocks of the noisy image. Instead of using all the patches of the noisy image, the authors propose an iterative strategy to adaptively choose the optimal set containing the patches with lowest variance. Although the method measures uniform Gaussian noise, it can be easily adapted to deal with signal-dependent noise, which is realistic with the Poisson noise model obtained by a CMOS or CCD device in a digital camera.

  11. Image Denoising Algorithm Combined with SGK Dictionary Learning and Principal Component Analysis Noise Estimation

    Directory of Open Access Journals (Sweden)

    Wenjing Zhao

    2018-01-01

    Full Text Available SGK (sequential generalization of K-means dictionary learning denoising algorithm has the characteristics of fast denoising speed and excellent denoising performance. However, the noise standard deviation must be known in advance when using SGK algorithm to process the image. This paper presents a denoising algorithm combined with SGK dictionary learning and the principal component analysis (PCA noise estimation. At first, the noise standard deviation of the image is estimated by using the PCA noise estimation algorithm. And then it is used for SGK dictionary learning algorithm. Experimental results show the following: (1 The SGK algorithm has the best denoising performance compared with the other three dictionary learning algorithms. (2 The SGK algorithm combined with PCA is superior to the SGK algorithm combined with other noise estimation algorithms. (3 Compared with the original SGK algorithm, the proposed algorithm has higher PSNR and better denoising performance.

  12. Investigation on Aerodynamic Noise Evaluation and Attenuation In a Globe Valve using CFD Analysis

    Directory of Open Access Journals (Sweden)

    S K Sreekala

    2016-03-01

    Full Text Available Noise pollution will soon become the third greatest menace to the human environment after air and water pollution. Since noise is a by-product of energy conversion, there will be increasing noise as the demand for energy for transportation, power, food, and chemicals increases. In the field of control equipment, noise produced by valves has become a focal point of attention .In this paper aerodynamic noise evaluation of a globe valve was carried out  using a three dimensional Computational Fluid Dynamic technique(CFD. The results obtained from numerical analysis are compared with the experimental measurements and are found   to be in good agreement. Reduction in sound pressure level was achieved by doubling the number of flow passages in the cage at full open condition and at the same operating conditions. Hence sound attenuation is established by changing the cage configuration with no change in total area of flow passage in the cage

  13. Biological Nanopores: Confined Spaces for Electrochemical Single-Molecule Analysis.

    Science.gov (United States)

    Cao, Chan; Long, Yi-Tao

    2018-02-20

    Nanopore sensing is developing into a powerful single-molecule approach to investigate the features of biomolecules that are not accessible by studying ensemble systems. When a target molecule is transported through a nanopore, the ions occupying the pore are excluded, resulting in an electrical signal from the intermittent ionic blockade event. By statistical analysis of the amplitudes, duration, frequencies, and shapes of the blockade events, many properties of the target molecule can be obtained in real time at the single-molecule level, including its size, conformation, structure, charge, geometry, and interactions with other molecules. With the development of the use of α-hemolysin to characterize individual polynucleotides, nanopore technology has attracted a wide range of research interest in the fields of biology, physics, chemistry, and nanoscience. As a powerful single-molecule analytical method, nanopore technology has been applied for the detection of various biomolecules, including oligonucleotides, peptides, oligosaccharides, organic molecules, and disease-related proteins. In this Account, we highlight recent developments of biological nanopores in DNA-based sensing and in studying the conformational structures of DNA and RNA. Furthermore, we introduce the application of biological nanopores to investigate the conformations of peptides affected by charge, length, and dipole moment and to study disease-related proteins' structures and aggregation transitions influenced by an inhibitor, a promoter, or an applied voltage. To improve the sensing ability of biological nanopores and further extend their application to a wider range of molecular sensing, we focus on exploring novel biological nanopores, such as aerolysin and Stable Protein 1. Aerolysin exhibits an especially high sensitivity for the detection of single oligonucleotides both in current separation and duration. Finally, to facilitate the use of nanopore measurements and statistical analysis

  14. Research on neutron noise analysis stochastic simulation method for α calculation

    International Nuclear Information System (INIS)

    Zhong Bin; Shen Huayun; She Ruogu; Zhu Shengdong; Xiao Gang

    2014-01-01

    The prompt decay constant α has significant application on the physical design and safety analysis in nuclear facilities. To overcome the difficulty of a value calculation with Monte-Carlo method, and improve the precision, a new method based on the neutron noise analysis technology was presented. This method employs the stochastic simulation and the theory of neutron noise analysis technology. Firstly, the evolution of stochastic neutron was simulated by discrete-events Monte-Carlo method based on the theory of generalized Semi-Markov process, then the neutron noise in detectors was solved from neutron signal. Secondly, the neutron noise analysis methods such as Rossia method, Feynman-α method, zero-probability method, and cross-correlation method were used to calculate a value. All of the parameters used in neutron noise analysis method were calculated based on auto-adaptive arithmetic. The a value from these methods accords with each other, the largest relative deviation is 7.9%, which proves the feasibility of a calculation method based on neutron noise analysis stochastic simulation. (authors)

  15. Report of the first United States conference on utility experience with neutron noise analysis

    International Nuclear Information System (INIS)

    Fry, D.N.; Horne, G.P.; Mayo, C.W.

    1984-01-01

    An informal meeting was held in Washington, D.C. on April 3 and 4, 1984, to discuss the current state of the art and experiences with neutron noise analysis in US pressurized water reactors (PWRs). The meeting was attended by 33 persons representing 11 utilities and 3 PWR reactor vendors as well as consultants, universities, and research laboratories. Presentations at the meeting covered several applications of neutron noise for diagnosing such things as vibrations induced by baffle jetting, detection of mechanical degradation of thermal shield supports, and electrical degradation of nuclear instrumentation channels. Twenty-one responses were obtained from a questionnaire circulated to all participants requesting their viewpoints and experiences regarding neutron noise analysis. The meeting participants concluded that a working group on neutron noise analysis should be formed to (1) establish a baseline library of neutron noise data, (2) provide a forum for communicating experiences with neutron noise surveillance, and (3) develop good practices and quality assurance procedures for neutron noise measurement and interpretation

  16. Indirect Electrochemical Analysis of Crocin in Phytochemical Sample

    Directory of Open Access Journals (Sweden)

    Riyaz Ahmad Dar

    2012-01-01

    Full Text Available A new electroanalytical method has been developed for the quantitative determination of crocin in a sample of stigmas of saffron (Crocus sativus L.. Crocin is polarographically inactive. However, cysteine in 0.02 M NaCl, pH=5.2±0.01 produces a well defined wave/peak with E1/2/Ep= –0.47/–0.45 V vs. Ag/AgCl. On recording polarograms of a set of solution containing a fixed concentration of cysteine and varying concentrations of crocin under aforesaid experimental conditions a gradual decrease in peak height/diffusion current and a negative shift in peak potential was observed. Thus, indicating cysteine-crocin interaction. Amperometric titration indicated crocin to cysteine ratio of 1:2. The above amperometric titration procedure has been used to determine the concentration of crocin in a sample of saffron. Crystallization process was carried out for the extraction of crocin from dried powder of saffron stigmas. The crystallized crocin was identified by UV-Visible spectrophotometry(at 255 nm and 442 nm and the quantitative analysis by the developed amperometric method. The concentration of crocin in saffron was found to be 2.13% and purity of isolated crocin 96.81%. The percent recovery varied from 98.56–100.31% and RSD (n=5 of 2.17%.The validation of the proposed procedure for the quantitative assay of crocin was examined via an evaluation of the repeatability, recovery, selectivity and relative standard deviation.

  17. Experiment and Simulation Analysis on Noise Attenuation of Al/MF Cylindrical Shells

    Directory of Open Access Journals (Sweden)

    Bin Li

    2017-01-01

    Full Text Available For the issue concerning internal noise reduction of Al-made cylindrical shell structure, the noise control method of laying melamine foam (MF layer is adopted for in-shell noise attenuation experiments of Al and Al/MF cylindrical shells and corresponding internal noise response spectrograms are obtained. Based on the Virtual.Lab acoustics software, a finite element model is established for the analysis of noise in the Al/MF cylinder shell and numerical simulation computation is conducted for the acoustic mode and in-shell acoustic response; the correctness of the finite element model is verified via comparison with measured data. On this basis, influence rules of different MF laying rate and different laying thickness on acoustic cavity resonance response within the low and medium frequency range of 100–400 Hz are studied. It is indicated that noise reduction increases with MF laying rate, but the amplification decreases along with the rising of MF laying rate; noise reduction per unit thickness decreases with the increase of laying thickness, while noise reduction per unit area increases.

  18. Background noise analysis in urban airport surroundings of Brazilian cities, Congonhas Airport, São Paulo

    Directory of Open Access Journals (Sweden)

    Fabio Scatolini

    Full Text Available ABSTRACT OBJECTIVE To perform a quantitative analysis of the background noise at Congonhas Airport surroundings based on large sampling and measurements with no interruption. METHODS Measuring sites were chosen from 62 and 72 DNL (day-night-level noise contours, in urban sites compatible with residential use. Fifteen sites were monitored for at least 168 hours without interruption or seven consecutive days. Data compilation was based on cross-reference between noise measurements and air traffic control records, and results were validated by airport meteorological reports. Preliminary diagnoses were established using the standard NBR-13368. Background noise values were calculated based on the Sound Exposure Level (SEL. Statistic parameters were calculated in one-hour intervals. RESULTS Only four of the fifteen sites assessed presented aircraft operations as a clear cause for the noise annoyance. Even so, it is possible to detect background noise levels above regulation limits during periods of low airport activity or when it closes at night. CONCLUSIONS All the sites monitored showed background noise levels above regulation limits between 7:00 and 21:00. In the intervals between 6:00-6:59 and 21:00-22:59 the noise data, when analyzed with the current airport operational characteristics, still allow the development of additional mitigating measures.

  19. Analysis of community response to transportation noise a quarter century after Schultz (1978)

    Science.gov (United States)

    Fidell, Sanford

    2003-10-01

    Transportation noise is a vexing and intrinsically controversial problem that has plagued societies since the beginnings of urban civilization. A function relating cumulative noise exposure to the prevalence of noise-induced annoyance [T. J. Schultz, ``Synthesis of social surveys on noise annoyance,'' J. Acoust. Soc. Am. 64, 377-405 (1978)] is the foundation for contemporary analyses of transportation noise effects on communities. The expenditures of billions of dollars in airplane ticket and fuel taxes for the construction of an airport infrastructure and for the mitigation of noise impacts in the United States are governed by policies ostensibly supported by a successor to Schultz's original ``synthesis'' curve. Many have grown so comfortable with the last quarter century's paradigm for transportation noise assessment and regulation, however, that they have lost sight of its underpinnings and limitations. A review of the historical and modern states of the art identifies persistent unresolved problems in the prediction and explanation of community response to transportation noise that are not fully addressed by descriptive dosage-effect analysis.

  20. An Application of the Acoustic Similarity Law to the Numerical Analysis of Centrifugal Fan Noise

    Science.gov (United States)

    Jeon, Wan-Ho; Lee, Duck-Joo; Rhee, Huinam

    Centrifugal fans, which are frequently used in our daily lives and various industries, usually make severe noise problems. Generally, the centrifugal fan noise consists of tones at the blade passing frequency and its higher harmonics. These tonal sounds come from the interaction between the flow discharged from the impeller and the cutoff in the casing. Prediction of the noise from a centrifugal fan becomes more necessary to optimize the design to meet both the performance and noise criteria. However, only some limited studies on noise prediction method exist because there are difficulties in obtaining detailed information about the flow field and casing effect on noise radiation. This paper aims to investigate the noise generation mechanism of a centrifugal fan and to develop a prediction method for the unsteady flow and acoustic pressure fields. In order to do this, a numerical analysis method using acoustic similarity law is proposed, and it is verified that the method can predict the noise generation mechanism very well by comparing the predicted results with available experimental results.

  1. Signal Processing for MoC brake rattle noise of moving vehicles using prony analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Cheol; Kwak, Yun Sang; Park, Jun Hong [Dept. of Mechanical Convergence Engineering, Hanyang University, Seoul (Korea, Republic of)

    2015-08-15

    To verify the possibility of generating rattling noise from a motor on caliper brake system, a test was conducted using a caliper excited with vibrations similar to that in a vehicle running on actual roads; this test was conducted using a quiet shaker installed in an anechoic room. After several hours of external excitation, the test assembly was loosened, and the frequency of rattling noise generation increased. A microphone was used to record the generated noise. The measured signals were analyzed by conventional spectrum analysis. Since the noise is generated as an impact response, the advantages of employing Prony analysis was discussed, and the results were compared to those obtained using conventional fast Fourier transforms. The accuracy of Prony analysis was through endurance tests on different brake systems.

  2. Electrochemical and genomic analysis of novel electroactive isolates obtained via potentiostatic enrichment from tropical sediment

    Science.gov (United States)

    Doyle, Lucinda E.; Yung, Pui Yi; Mitra, Sumitra D.; Wuertz, Stefan; Williams, Rohan B. H.; Lauro, Federico M.; Marsili, Enrico

    2017-07-01

    Enrichment of electrochemically-active microorganisms (EAM) to date has mostly relied on microbial fuel cells fed with wastewater. This study aims to enrich novel EAM by exposing tropical sediment, not frequently reported in the literature, to sustained anodic potentials. Voltamperometric techniques and electrochemical impedance spectroscopy, performed over a wide range of potentials, characterise extracellular electron transfer (EET) over time. Applied potential is found to affect biofilm electrochemical signature. Geobacter metallireducens is heavily enriched on the electrodes, as determined by metagenomic and metatranscriptomic analysis, in the first report of the species in a lactate-fed system. Two novel isolates are grown in pure culture from the enrichment, identified by 16S rRNA gene sequencing as Aeromonas and Enterobacter, respectively. The names proposed are Aeromonas sp. CL-1 and Enterobacter sp. EA-1. Both isolates are capable of EET on carbon felt and screen-printed carbon electrodes without the addition of exogenous redox mediators. Enterobacter sp. EA-1 can also perform mediated electron transfer using the soluble redox mediator 2-hydroxy-1,4-naphthoquinone (HNQ). Both isolates are able to use acetate and lactate as electron donors. This work outlines a comprehensive methodology for characterising novel EAM from unconventional inocula.

  3. Electrochemical analysis of gold-coated magnetic nanoparticles for detecting immunological interaction

    International Nuclear Information System (INIS)

    Pham, Thao Thi-Hien; Sim, Sang Jun

    2010-01-01

    An electrochemical impedance immunosensor was developed for detecting the immunological interaction between human immunoglobulin (IgG) and protein A from Staphylococcus aureus based on the immobilization of human IgG on the surface of modified gold-coated magnetic nanoparticles. The nanoparticles with an Au shell and Fe oxide cores were functionalized by a self-assembled monolayer of 11-mercaptoundecanoic acid. The electrochemical analysis was conducted on the modified magnetic carbon paste electrodes with the nanoparticles. The magnetic nanoparticles were attached to the surface of the magnetic carbon paste electrodes via magnetic force. The cyclic voltammetry technique and electrochemical impedance spectroscopy measurements of the magnetic carbon paste electrodes coated with magnetic nanoparticles-human IgG complex showed changes in its alternating current (AC) response both after the modification of the surface of the electrode and the addition of protein A. The immunological interaction between human IgG on the surface of the modified magnetic carbon paste electrodes and protein A in the solution could be successfully monitored.

  4. In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating

    Directory of Open Access Journals (Sweden)

    Nicolas A. Alba

    2015-10-01

    Full Text Available Neural electrodes hold tremendous potential for improving understanding of brain function and restoring lost neurological functions. Multi-walled carbon nanotube (MWCNT and dexamethasone (Dex-doped poly(3,4-ethylenedioxythiophene (PEDOT coatings have shown promise to improve chronic neural electrode performance. Here, we employ electrochemical techniques to characterize the coating in vivo. Coated and uncoated electrode arrays were implanted into rat visual cortex and subjected to daily cyclic voltammetry (CV and electrochemical impedance spectroscopy (EIS for 11 days. Coated electrodes experienced a significant decrease in 1 kHz impedance within the first two days of implantation followed by an increase between days 4 and 7. Equivalent circuit analysis showed that the impedance increase is the result of surface capacitance reduction, likely due to protein and cellular processes encapsulating the porous coating. Coating’s charge storage capacity remained consistently higher than uncoated electrodes, demonstrating its in vivo electrochemical stability. To decouple the PEDOT/MWCNT material property changes from the tissue response, in vitro characterization was conducted by soaking the coated electrodes in PBS for 11 days. Some coated electrodes exhibited steady impedance while others exhibiting large increases associated with large decreases in charge storage capacity suggesting delamination in PBS. This was not observed in vivo, as scanning electron microscopy of explants verified the integrity of the coating with no sign of delamination or cracking. Despite the impedance increase, coated electrodes successfully recorded neural activity throughout the implantation period.

  5. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems

    International Nuclear Information System (INIS)

    Bouwman, R; Broeders, M; Van Engen, R; Young, K; Lazzari, B; Ravaglia, V

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does not discriminate sufficiently between systems with and without additional noise besides quantum noise. This paper attempts to give an alternative and relatively simple method for noise analysis which can divide noise into electronic noise, structured noise and quantum noise. Quantum noise needs to be the dominant noise source in clinical images for optimal performance of a digital mammography system, and therefore the amount of electronic and structured noise should be minimal. For several digital mammography systems, the noise was separated into components based on the measured pixel value, standard deviation (SD) of the image and the detector entrance dose. The results showed that differences between systems exist. Our findings confirm that the proposed method is able to discriminate systems based on their noise performance and is able to detect possible quality problems. Therefore, we suggest to replace the current method for noise analysis as described in the European Guidelines by the alternative method described in this paper.

  6. Evaluation and Analysis of Road Traffic Noise in Asansol: An Industrial Town of Eastern India

    Directory of Open Access Journals (Sweden)

    A. Gangopadhyay

    2008-09-01

    Full Text Available The objectives of the study were to monitor and assess the road traffic noise in its spatial-temporal aspect in an urban area. The paper discusses the observations, results and their interpretation based on the study. Noise recordings from site, collected from April 2006 to March 2006, were used for statistical analysis and generation of various noise indices. Noise maps were also created for impact analysis and formulation of Noise Risk Zones. Mean Ldn value ranged between 55.1 and 87.3 dB (A. Day time Leq level ranged between 51.2 and 89.0 dB (A, where it ranged between 43.5 and 81.9 dB (A during night. The study reveals that present noise level in all the locations exceeds the limit prescribed by CPCB. Based on the finding it can be said that the population in this industrial town are exposed to significantly high noise level, which is caused mostly due to road traffic.

  7. Annual modulation of the galactic binary confusion noise background and LISA data analysis

    International Nuclear Information System (INIS)

    Seto, Naoki

    2004-01-01

    We study the anisotropies of the galactic confusion noise background and its effects on LISA data analysis. LISA has two data streams of gravitational wave signals relevant for the low frequency regime. Because of the anisotropies of the background, the matrix for their confusion noises has off-diagonal components and depends strongly on the orientation of the detector plane. We find that the sky-averaged confusion noise level √(S(f)) could change by a factor of 2 in 3 months and would be minimum when the orbital position of LISA is around either the spring or autumn equinox

  8. Automotive Exterior Noise Optimization Using Grey Relational Analysis Coupled with Principal Component Analysis

    Science.gov (United States)

    Chen, Shuming; Wang, Dengfeng; Liu, Bo

    This paper investigates optimization design of the thickness of the sound package performed on a passenger automobile. The major characteristics indexes for performance selected to evaluate the processes are the SPL of the exterior noise and the weight of the sound package, and the corresponding parameters of the sound package are the thickness of the glass wool with aluminum foil for the first layer, the thickness of the glass fiber for the second layer, and the thickness of the PE foam for the third layer. In this paper, the process is fundamentally with multiple performances, thus, the grey relational analysis that utilizes grey relational grade as performance index is especially employed to determine the optimal combination of the thickness of the different layers for the designed sound package. Additionally, in order to evaluate the weighting values corresponding to various performance characteristics, the principal component analysis is used to show their relative importance properly and objectively. The results of the confirmation experiments uncover that grey relational analysis coupled with principal analysis methods can successfully be applied to find the optimal combination of the thickness for each layer of the sound package material. Therefore, the presented method can be an effective tool to improve the vehicle exterior noise and lower the weight of the sound package. In addition, it will also be helpful for other applications in the automotive industry, such as the First Automobile Works in China, Changan Automobile in China, etc.

  9. Noise analysis of fluid-valve system in a linear compressor using CAE

    International Nuclear Information System (INIS)

    Lee, Jun Ho; Jeong, Weui Bong; Kim, Dang Ju

    2009-01-01

    A linear compressor in a refrigerator uses piston motion to transfer refrigerant so its efficiency is higher than a previous reciprocal compressor. Because of interaction between refrigerant and valves system in the linear compressor, however, noise has been a main issue. In spite of doing many experimental researches, there is no way to rightly predict the noise. In order to solve this limitation, the CAE analysis is applied. For giving credit to these computational data, all of the data are experimentally validated.

  10. Deconvolution under Poisson noise using exact data fidelity and synthesis or analysis sparsity priors

    OpenAIRE

    Dupé , François-Xavier; Fadili , Jalal M.; Starck , Jean-Luc

    2012-01-01

    International audience; In this paper, we propose a Bayesian MAP estimator for solving the deconvolution problems when the observations are corrupted by Poisson noise. Towards this goal, a proper data fidelity term (log-likelihood) is introduced to reflect the Poisson statistics of the noise. On the other hand, as a prior, the images to restore are assumed to be positive and sparsely represented in a dictionary of waveforms such as wavelets or curvelets. Both analysis and synthesis-type spars...

  11. New Techniques for Thermo-electrochemical Analysis of Lithium-ion Batteries for Space Applications

    Science.gov (United States)

    Walker, William; Ardebili, H.

    2013-01-01

    The overall goal of this study was achieved: Replicated the numerical assessment performed by Chen et. al. (2005). Displayed the ability of Thermal Desktop to be coupled with thermo-electrochemical analysis techniques. such that the local heat generated on the cells is a function of the model itself using logic blocks and arrays. Differences in the TD temperature vs. depth of discharge profiles and Chen's was most likely due to differences in two primary areas: Contact regions and conductance values. Differences in density and specific heat values. center dot The model results are highly dependent on the accuracy of the material properties with respect to the multiple layers of an individual cell.

  12. Osmium tetroxide complexes as versatile tools for structure probing and electrochemical analysis of biopolymers

    Czech Academy of Sciences Publication Activity Database

    Fojta, Miroslav; Kostečka, Pavel; Pivoňková, Hana; Horáková Brázdilová, Petra; Havran, Luděk

    2011-01-01

    Roč. 7, č. 1 (2011), s. 35-50 ISSN 1573-4110 R&D Projects: GA AV ČR(CZ) IAA400040901; GA AV ČR(CZ) IAA400040903; GA ČR(CZ) GP203/08/P598; GA MŠk(CZ) LC06035 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : osmium complexes * DNA labelling * electrochemical analysis Subject RIV: BO - Biophysics Impact factor: 1.000, year: 2011

  13. Temperature noise analysis and sodium boiling detection in the fuel failure mockup

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Fry, D.N.; Leavell, W.H.; Mathis, M.V.; Saxe, R.F.

    1976-01-01

    Sodium temperature noise was measured at the exit of simulated, fast-reactor fuel subassemblies in the Fuel Failure Mockup (FFM) to determine the feasibility of using temperature noise monitors to detect flow blockages in fast reactors. Also, acoustic noise was measured to determine whether sodium boiling in the FFM could be detected acoustically and whether noncondensable gas entrained in the sodium coolant would affect the sensitivity of the acoustic noise detection system. Information from these studies would be applied to the design of safety systems for operating liquid-metal fast breeder reactors (LMFBRs). It was determined that the statistical properties of temperature noise are dependent on the shape of temperature profiles across the subassemblies, and that a blockage upstream of a thermocouple that increases the gradient of the profile near the blockage will also increase the temperature noise at the thermocouple. Amplitude probability analysis of temperature noise shows a skewed amplitude density function about the mean temperature that varies with the location of the thermocouple with respect to the blockage location. It was concluded that sodium boiling in the FFM could be detected acoustically. However, entrained noncondensable gas in the sodium coolant at void fractions greater than 0.4 percent attenuated the acoustic signals sufficiently that boiling was not detected. At a void fraction of 0.1 percent, boiling was indicated only by the two acoustic detectors closest to the boiling site

  14. Microstructure analysis for quantification of Barkhausen noise method and nondestructive evaluation of fracture characteristics

    International Nuclear Information System (INIS)

    Kim, Dong Won; Kwon, Dong Il

    1999-01-01

    Barkhausen noise method as a magnetic nondestructive test has the advantages for evaluating the properties of magnetic material more precisely and high-sensitively compared to other magnetic NDT methods. For a long time Barkhausen noise method was applied to measure the bulk magnetic properties of magnetic materials and recently to evaluate microstructure, stress analysis, fatigue, creep, and fracture characteristics as a NDT method. But so far Barkhausen noise method has been used as evaluating orientation of material properties rather qualitatively. For this reason, many NDT testing methods have seldom been applied to industrial plants and laboratories. In this study we make experiments on the variation of Barkhausen noise as microstructure, and quantify Barkhausen noise(rms voltage) via formula of velocity of magnetic domain walls using coercive force as retarding force of domain wall movement. As a result, we could evaluate the microstructure of magnetic materials and trends of fracture toughness quantitatively by measuring Barkhausen noise, therefore directly evaluate microstructure and fracture toughness by Barkhausen noise method as accurate in-situ nondestructive testing method.

  15. Experience gained with capacitive pressure sensor noise analysis

    International Nuclear Information System (INIS)

    Ballestrin, J.; Blazquez, J.

    1996-01-01

    Due to safety requirements, pressure sensors in a nuclear power plant must be kept under surveillance. The dynamics of the capacitive type Rosemount sensors is known. Sensor response time to a pressure ramp is the usual quantity required and it can be calculated. The noise signals contain the sensor dynamics, but in this case other irrelevant information from the plant is held, which disturbs the results. So, the signals must be conditioned previously. Also, it is necessary to do a process in order to separate the pressure sensor dynamics and to get a stationary signal. This can be done by using the autocorrelation function and filtering. Deterministic steps have been made and a relationship between the sensor response time, and the static pressure has been found. (author)

  16. Tracing of border trap behavior by noise analysis in microelectronics

    International Nuclear Information System (INIS)

    Sharshar, K.A.A.; Shaalan, A.A.M.; Gomaa, E.I.

    2008-01-01

    The present state of art of this work is to study the electrical defects of the silicon- silicon dioxide interface created by gamma rays (Co 60 ) in submicron MOS devices used in telecommunication systems. We focus our investigation on a particular class of trapped charge located near the interface characterized as the border traps. The expected physical location and chemical structure of the traps were discussed. The low frequency 1/f noise measurement is used in the estimation of border trap densities before and after irradiation; the results are reported for n-MOS transistor exposed to doses (0.3, 0.5, 1 and 10 Mrad). The border trap population in the irradiated samples increased from 7.6*10 10 up to 1.03*10 11 eV -1 Cm -2

  17. Analysis of impact noise induced by hitting of titanium head golf driver.

    Science.gov (United States)

    Kim, Young Ho; Kim, Young Chul; Lee, Jun Hee; An, Yong-Hwi; Park, Kyung Tae; Kang, Kyung Min; Kang, Yeon June

    2014-11-01

    The hitting of titanium head golf driver against golf ball creates a short duration, high frequency impact noise. We analyzed the spectra of these impact noises and evaluated the auditory hazards from exposure to the noises. Noises made by 10 titanium head golf drivers with five maximum hits were collected, and the spectra of the pure impact sounds were studied using a noise analysis program. The noise was measured at 1.7 m (position A) and 3.4 m (position B) from the hitting point in front of the hitter and at 3.4 m (position C) behind the hitting point. Average time duration was measured and auditory risk units (ARUs) at position A were calculated using the Auditory Hazard Assessment Algorithm for Humans. The average peak levels at position A were 119.9 dBA at the sound pressure level (SPL) peak and 100.0 dBA at the overall octave level. The average peak levels (SPL and overall octave level) at position B were 111.6 and 96.5 dBA, respectively, and at position C were 111.5 and 96.7 dBA, respectively. The average time duration and ARUs measured at position A were 120.6 ms and 194.9 units, respectively. Although impact noises made by titanium head golf drivers showed relatively low ARUs, individuals enjoying golf frequently may be susceptible to hearing loss due to the repeated exposure of this intense impact noise with short duration and high frequency. Unprotected exposure to impact noises should be limited to prevent cochleovestibular disorders.

  18. An Analysis of Sawtooth Noise in the Timing SynPaQ III GPS Sensor

    Directory of Open Access Journals (Sweden)

    Yuriy S. SHMALIY

    2007-05-01

    Full Text Available This paper addresses a probabilistic analysis of sawtooth noise in the one pulse per second (1PPS output of the timing SynPaQ III GPS Sensor. We show that sawtooth noise is uniformly distributed within the bounds caused by period of the Local Time Clock of the sensor and that the probability density function (pdf of this noise is formed with 1ns sampling interval used in the sensor to calculate the negative sawtooth. We also show that the pdf has at zero a spike of 1ns width caused by roll-off. It is demonstrated that an unbiased finite impulse response filter is an excellent suppresser of such a noise in the estimates of the time interval errors of local clocks.

  19. A Single Electrochemical Probe Used for Analysis of Multiple Nucleic Acid Sequences

    Science.gov (United States)

    Mills, Dawn M.; Calvo-Marzal, Percy; Pinzon, Jeffer M.; Armas, Stephanie; Kolpashchikov, Dmitry M.; Chumbimuni-Torres, Karin Y.

    2017-01-01

    Electrochemical hybridization sensors have been explored extensively for analysis of specific nucleic acids. However, commercialization of the platform is hindered by the need for attachment of separate oligonucleotide probes complementary to a RNA or DNA target to an electrode’s surface. Here we demonstrate that a single probe can be used to analyze several nucleic acid targets with high selectivity and low cost. The universal electrochemical four-way junction (4J)-forming (UE4J) sensor consists of a universal DNA stem-loop (USL) probe attached to the electrode’s surface and two adaptor strands (m and f) which hybridize to the USL probe and the analyte to form a 4J associate. The m adaptor strand was conjugated with a methylene blue redox marker for signal ON sensing and monitored using square wave voltammetry. We demonstrated that a single sensor can be used for detection of several different DNA/RNA sequences and can be regenerated in 30 seconds by a simple water rinse. The UE4J sensor enables a high selectivity by recognition of a single base substitution, even at room temperature. The UE4J sensor opens a venue for a re-useable universal platform that can be adopted at low cost for the analysis of DNA or RNA targets. PMID:29371782

  20. Structural and electrochemical analysis of chemically synthesized microcubic architectured lead selenide thin films

    Science.gov (United States)

    Bhat, T. S.; Shinde, A. V.; Devan, R. S.; Teli, A. M.; Ma, Y. R.; Kim, J. H.; Patil, P. S.

    2018-01-01

    The present work deals with the synthesis of lead selenide (PbSe) thin films by simple and cost-effective chemical bath deposition method with variation in deposition time. The structural, morphological, and electrochemical properties of as-deposited thin films were examined using characterization techniques such as X-ray diffraction spectroscopy (XRD), field-emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV), galvanostatic charge-discharge and electrochemical impedance spectroscopy. XRD reveals formation of rock salt phase cubic structured PbSe. FE-SEM images show the formation of microcubic structured morphology. The existence of the PbSe is confirmed from the XPS analysis. On the other hand, CV curves show four reaction peaks corresponding to oxidation [PbSe and Pb(OH)2] and reduction (PbO2 and Pb(OH)2) at the surface of PbSe thin films. The PbSe:2 sample deposited for 80 min. shows maximum specific capacitance of 454 ± 5 F g- 1 obtained at 0.25 mA cm- 2 current density. The maximum energy density of 69 Wh kg- 1 was showed by PbSe:2 electrode with a power density of 1077 W kg- 1. Furthermore, electrochemical impedance studies of PbSe:2 thin film show 80 ± 3% cycling stability even after 500 CV cycles. Such results show the importance of microcubic structured PbSe thin film as an anode in supercapacitor devices.

  1. Comparison of occupational noise legislation in the Americas: An overview and analysis

    Directory of Open Access Journals (Sweden)

    Jorge P Arenas

    2014-01-01

    Full Text Available The workplace contributes significantly to the total dose of daily noise to which a person is subjected. Therefore, millions of people around the world are exposed to potentially dangerous noise levels and consequently, there is an urgent, global need for legislation to adequately protect the auditory health of workers. Occupational noise legislation has been adopted in many of the countries with different degrees of comprehensiveness and varying levels of sophistication. This paper presents a global view of current legislation on occupational noise in the 22 countries that make up the Americas, that is, Latin America, Canada, and the United States. Upon analysis of the legislation, there are notable differences among countries in the defined values for permissible exposure limit (PEL and exchange rate. Of the countries that have regulations, the majority (81% use a PEL of 85 dBA. A PEL of 85 dBA and the 3-dB exchange rate are currently used by 32% of the nations in the Americas. Most nations limit impulsive noise exposure to a peak unweighted sound pressure level of 140 dB (or dBC, while a few use slightly lower limits. However, 27% of the countries in the region still have not established regulations with respect to permissible noise levels and exchange rates. This fact is leaving millions of workers in the Americas unprotected against occupational noise. Provide an overview and analysis of the current legislation on occupational noise in the 22 countries that make up the Americas. The information on legislation, regulations, and standards discussed in this paper were obtained directly from official government sources in each country, the International Labour Organization database, or through various colleagues in each country. (1 There are notable differences among countries in the defined values for PEL and exchange rate. (2 Of the countries that have regulations, the majority (81% use a PEL of 85 dBA. A PEL of 85 dBA and the 3-dB exchange

  2. Summary of the fourth conference on United States utility experience in reactor noise analysis

    International Nuclear Information System (INIS)

    Fry, D.N.

    1987-01-01

    The fourth informal conference on United States utility experience in reactor noise analysis and loose-part monitoring was held at the Northeast Utilities Service Company offices in Hartford, Connecticut, May 12-14, 1987. Host and general chairman for the meeting was J.V. Persio of Northeast Utilities. This conference provided a forum where utilities could share information on reactor noise analysis on an informal basis. There were about 60 attendees at the meeting representing 10 utilities, 3 reactor vendors, 8 consulting organizations, and 4 universities and research laboratories. Twenty-three papers were presented at the conference, dealing with various aspects of loose-part monitoring, neutron noise analysis, and standards activities

  3. The importance of stimulus noise analysis for self-motion studies.

    Directory of Open Access Journals (Sweden)

    Alessandro Nesti

    Full Text Available Motion simulators are widely employed in basic and applied research to study the neural mechanisms of perception and action during inertial stimulation. In these studies, uncontrolled simulator-introduced noise inevitably leads to a disparity between the reproduced motion and the trajectories meticulously designed by the experimenter, possibly resulting in undesired motion cues to the investigated system. Understanding actual simulator responses to different motion commands is therefore a crucial yet often underestimated step towards the interpretation of experimental results. In this work, we developed analysis methods based on signal processing techniques to quantify the noise in the actual motion, and its deterministic and stochastic components. Our methods allow comparisons between commanded and actual motion as well as between different actual motion profiles. A specific practical example from one of our studies is used to illustrate the methodologies and their relevance, but this does not detract from its general applicability. Analyses of the simulator's inertial recordings show direction-dependent noise and nonlinearity related to the command amplitude. The Signal-to-Noise Ratio is one order of magnitude higher for the larger motion amplitudes we tested, compared to the smaller motion amplitudes. Simulator-introduced noise is found to be primarily of deterministic nature, particularly for the stronger motion intensities. The effect of simulator noise on quantification of animal/human motion sensitivity is discussed. We conclude that accurate recording and characterization of executed simulator motion are a crucial prerequisite for the investigation of uncertainty in self-motion perception.

  4. Analysis of jet-airfoil interaction noise sources by using a microphone array technique

    Science.gov (United States)

    Fleury, Vincent; Davy, Renaud

    2016-03-01

    The paper is concerned with the characterization of jet noise sources and jet-airfoil interaction sources by using microphone array data. The measurements were carried-out in the anechoic open test section wind tunnel of Onera, Cepra19. The microphone array technique relies on the convected, Lighthill's and Ffowcs-Williams and Hawkings' acoustic analogy equation. The cross-spectrum of the source term of the analogy equation is sought. It is defined as the optimal solution to a minimal error equation using the measured microphone cross-spectra as reference. This inverse problem is ill-posed yet. A penalty term based on a localization operator is therefore added to improve the recovery of jet noise sources. The analysis of isolated jet noise data in subsonic regime shows the contribution of the conventional mixing noise source in the low frequency range, as expected, and of uniformly distributed, uncorrelated noise sources in the jet flow at higher frequencies. In underexpanded supersonic regime, a shock-associated noise source is clearly identified, too. An additional source is detected in the vicinity of the nozzle exit both in supersonic and subsonic regimes. In the presence of the airfoil, the distribution of the noise sources is deeply modified. In particular, a strong noise source is localized on the flap. For high Strouhal numbers, higher than about 2 (based on the jet mixing velocity and diameter), a significant contribution from the shear-layer near the flap is observed, too. Indications of acoustic reflections on the airfoil are also discerned.

  5. Identification of noise in linear data sets by factor analysis

    International Nuclear Information System (INIS)

    Roscoe, B.A.; Hopke, Ph.K.

    1982-01-01

    A technique which has the ability to identify bad data points, after the data has been generated, is classical factor analysis. The ability of classical factor analysis to identify two different types of data errors make it ideally suited for scanning large data sets. Since the results yielded by factor analysis indicate correlations between parameters, one must know something about the nature of the data set and the analytical techniques used to obtain it to confidentially isolate errors. (author)

  6. Multiple performance optimization of electrochemical drilling of Inconel 625 using Taguchi based Grey Relational Analysis

    Directory of Open Access Journals (Sweden)

    N. Manikandan

    2017-04-01

    Full Text Available In this present investigation, a multi performance characteristics optimization based on Taguchi approach with Grey Relational Analysis (GRA is proposed for Electrochemical Drilling process on Inconel 625 material which is used for marine, nuclear, aerospace applications, especially in corrosive environments. Experimental runs have been planned as per Taguchi’s principle with three input machining variables such as feed rate, flow rate of electrolyte and concentration of electrolyte. Besides the material removal rate and surface roughness, the geometric measures such as overcut, form and orientation tolerance are included as performance measures in this investigation. Outcomes of the analysis show that the feed rate is the predominant variable for the desired performance characteristics. On establishing the desired performance measures and multiple regression models are developed to be used as predictive tools. The confirmation test also conducted to validate the results attained by GRA approach and affirmed that there is considerable improvement with the help of proposed approach.

  7. Nanomaterials in electrochemical biosensors for pesticide detection: advances and challenges in food analysis

    International Nuclear Information System (INIS)

    Arduini, Fabiana; Moscone, Danila; Cinti, Stefano; Scognamiglio, Viviana

    2016-01-01

    This overview (with 114 refs.) covers the progress made between 2010 and 2015 in the field of nanomaterial based electrochemical biosensors for pesticides in food. Its main focus is on strategies to analyze real samples. The review first gives a short introduction into the most often used bio recognition elements. These include (a) enzymes (resulting in inhibition-based and direct catalytic biosensors), (b) antibodies (resulting in immunosensors), and (c) aptamers (resulting in aptasensors). The next main section covers the various kinds of nanomaterials for use in biosensors and includes carbonaceous species (carbon nanotubes, graphene, carbon black and others), and non-carbonaceous species in the form of nanoparticles, rods, or porous materials. Aspects of sample treatment and real sample analysis are treated next before discussing vanguard technologies in tailor-made food analysis. (author)

  8. Diffraction efficiency and noise analysis of hidden image holograms

    DEFF Research Database (Denmark)

    Tamulevičius, Sigitas; Andrulevičius, Mindaugas; Puodžiukynas, Linas

    2017-01-01

    recorded in a photoresist layer spin-coated on glass substrates applying laser interference lithography technique. Both analogue and digital analysis approaches showed the similar results thus confirming the appropriateness of the used analysis methods. It was found that holograms recorded at higher laser...

  9. Noise removal using factor analysis of dynamic structures: application to cardiac gated studies.

    Science.gov (United States)

    Bruyant, P P; Sau, J; Mallet, J J

    1999-10-01

    Factor analysis of dynamic structures (FADS) facilitates the extraction of relevant data, usually with physiologic meaning, from a dynamic set of images. The result of this process is a set of factor images and curves plus some residual activity. The set of factor images and curves can be used to retrieve the original data with reduced noise using an inverse factor analysis process (iFADS). This improvement in image quality is expected because the inverse process does not use the residual activity, assumed to be made of noise. The goal of this work is to quantitate and assess the efficiency of this method on gated cardiac images. A computer simulation of a planar cardiac gated study was performed. The simulated images were added with noise and processed by the FADS-iFADS program. The signal-to-noise ratios (SNRs) were compared between original and processed data. Planar gated cardiac studies from 10 patients were tested. The data processed by FADS-iFADS were subtracted to the original data. The result of the substraction was studied to evaluate its noisy nature. The SNR is about five times greater after the FADS-iFADS process. The difference between original and processed data is noise only, i.e., processed data equals original data minus some white noise. The FADS-iFADS process is successful in the removal of an important part of the noise and therefore is a tool to improve the image quality of cardiac images. This tool does not decrease the spatial resolution (compared with smoothing filters) and does not lose details (compared with frequential filters). Once the number of factors is chosen, this method is not operator dependent.

  10. The use of magnetic Barkhausen noise analysis for nondestructive determination of stresses in structural elements

    International Nuclear Information System (INIS)

    Silva Junior, Silverio Ferreira da; Mansur, Tanius Rodrigues; Cruz, Julio Ricardo Barreto

    2007-01-01

    The knowledge about the stress state acting in structural elements has significant importance in the structural integrity evaluation of a specific component. The magnetic Barkhausen noise analysis can be used for this purpose. As a nondestructive testing method, it presents the advantage of not promote any changes in the tested component. In this paper, a study about the use of this new nondestructive test method for stress measurements is presented. The test system configuration and the reference standards used for this purpose, as well as the optimum test parameters determination are discussed. The experiments were carried out in ASTM A-36 steel, used for structural components manufacturing. A structure of this material was loaded and the resulting stresses were determined from strain gage measurements and Barkhausen noise analysis. The results obtained have showed a good sensitivity of the magnetic Barkhausen noise to stress changes occurred in the material. The main advantages and limitations of this test method for stress measurements are presented. (author)

  11. Application of neutron noise analysis to a swimming pool research reactor

    International Nuclear Information System (INIS)

    Behringer, K.; Lescano, V.H.; Meier, F.; Phildius, J.; Winkler, H.

    1982-01-01

    This work is part of a programme of establishing practical applications of neutron noise techniques to a swimming pool research reactor and deals with two different items: (1) The identification of local boiling caused e.g. by a partial blockage of the coolant flow in a fuel element. Local boiling can easily lead to a burn-out situation. The onset of boiling can be detected by neutron noise analysis and a boiling detection system is presently under development. (2) The measurement of the time evolution of the reactivity induced by xenon after reactor shut-down by an on-line reactivity meter based on neutron noise analysis. From the data, the prompt neutron decay constant at delayed critical, the equilibrium xenon reactivity worth, and an estimate of the average steady-state power flux in the core before reactor shut-down were obtained. (author)

  12. Phase noise analysis of clock recovery based on an optoelectronic phase-locked loop

    DEFF Research Database (Denmark)

    Zibar, Darko; Mørk, Jesper; Oxenløwe, Leif Katsuo

    2007-01-01

    A detailed theoretical analysis of a clock-recovery (CR) scheme based on an optoelectronic phase-locked loop is presented. The analysis emphasizes the phase noise performance, taking into account the noise of the input data signal, the local voltage-controlled oscillator (VCO), and the laser....... It is shown that a large loop length results in a higher timing jitter of the recovered clock signal. The impact of the loop length on the clock signal jitter can be reduced by using a low-noise VCO and a low loop filter bandwidth. Using the model, the timing jitter of the recovered optical and electrical...... clock signal can be evaluated. We numerically investigate the timing jitter requirements for combined electrical/optical local oscillators, in order for the recovered clock signal to have less jitter than that of the input signal. The timing jitter requirements for the free-running laser and the VCO...

  13. Determination of fuel assembly vibrational modes through analysis of incore detector noise

    International Nuclear Information System (INIS)

    Johnson, R.S.

    1986-01-01

    In order to better characterize fuel assembly vibration at Duke Power Company's Oconee Nuclear Station, incore noise data were acquired an analyzed from prompt responding detectors incorporated in the Oconee 2, Cycle 7 core. Duke Power Company began actively pursuing an inhouse Neutron Noise Analysis program for routine surveillance of reactor internals vibration in 1979. Noise data has since been acquired and analyzed for twelve cycles of operation for the three Oconee units. Duke Power's Oconee Unit 2 is a Babcock and Wilcoxs pressurized water reactor with a rate thermal power of 2568MW. For Oconee 2, Cycle 7 operation, two test assemblies, each employing a string of seven axially-spaced, prompt responding hafnium detectors, were included in the final core design. Incore detector noise data were obtained during Cycle 7 at approximately 281 and 430 effective full power days (EFPD). In addition to the incore test detector signals, noise signals from the upper and lower chambers of the four excore power range detectors were recorded to aid in the analysis. The comparison of RMS signal levels for each incore detector and the phase relationships between detector locations within two test assemblies identified the first four fuel assembly bending modes associated with fixed end conditions

  14. 3D seismic data de-noising and reconstruction using Multichannel Time Slice Singular Spectrum Analysis

    Science.gov (United States)

    Rekapalli, Rajesh; Tiwari, R. K.; Sen, Mrinal K.; Vedanti, Nimisha

    2017-05-01

    Noises and data gaps complicate the seismic data processing and subsequently cause difficulties in the geological interpretation. We discuss a recent development and application of the Multi-channel Time Slice Singular Spectrum Analysis (MTSSSA) for 3D seismic data de-noising in time domain. In addition, L1 norm based simultaneous data gap filling of 3D seismic data using MTSSSA also discussed. We discriminated the noises from single individual time slices of 3D volumes by analyzing Eigen triplets of the trajectory matrix. We first tested the efficacy of the method on 3D synthetic seismic data contaminated with noise and then applied to the post stack seismic reflection data acquired from the Sleipner CO2 storage site (pre and post CO2 injection) from Norway. Our analysis suggests that the MTSSSA algorithm is efficient to enhance the S/N for better identification of amplitude anomalies along with simultaneous data gap filling. The bright spots identified in the de-noised data indicate upward migration of CO2 towards the top of the Utsira formation. The reflections identified applying MTSSSA to pre and post injection data correlate well with the geology of the Southern Viking Graben (SVG).

  15. Boundary layer noise subtraction in hydrodynamic tunnel using robust principal component analysis.

    Science.gov (United States)

    Amailland, Sylvain; Thomas, Jean-Hugh; Pézerat, Charles; Boucheron, Romuald

    2018-04-01

    The acoustic study of propellers in a hydrodynamic tunnel is of paramount importance during the design process, but can involve significant difficulties due to the boundary layer noise (BLN). Indeed, advanced denoising methods are needed to recover the acoustic signal in case of poor signal-to-noise ratio. The technique proposed in this paper is based on the decomposition of the wall-pressure cross-spectral matrix (CSM) by taking advantage of both the low-rank property of the acoustic CSM and the sparse property of the BLN CSM. Thus, the algorithm belongs to the class of robust principal component analysis (RPCA), which derives from the widely used principal component analysis. If the BLN is spatially decorrelated, the proposed RPCA algorithm can blindly recover the acoustical signals even for negative signal-to-noise ratio. Unfortunately, in a realistic case, acoustic signals recorded in a hydrodynamic tunnel show that the noise may be partially correlated. A prewhitening strategy is then considered in order to take into account the spatially coherent background noise. Numerical simulations and experimental results show an improvement in terms of BLN reduction in the large hydrodynamic tunnel. The effectiveness of the denoising method is also investigated in the context of acoustic source localization.

  16. Poisson–Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain

    Science.gov (United States)

    Lee, Sangyoon; Lee, Min Seok; Kang, Moon Gi

    2018-01-01

    The noise distribution of images obtained by X-ray sensors in low-dosage situations can be analyzed using the Poisson and Gaussian mixture model. Multiscale conversion is one of the most popular noise reduction methods used in recent years. Estimation of the noise distribution of each subband in the multiscale domain is the most important factor in performing noise reduction, with non-subsampled contourlet transform (NSCT) representing an effective method for scale and direction decomposition. In this study, we use artificially generated noise to analyze and estimate the Poisson–Gaussian noise of low-dose X-ray images in the NSCT domain. The noise distribution of the subband coefficients is analyzed using the noiseless low-band coefficients and the variance of the noisy subband coefficients. The noise-after-transform also follows a Poisson–Gaussian distribution, and the relationship between the noise parameters of the subband and the full-band image is identified. We then analyze noise of actual images to validate the theoretical analysis. Comparison of the proposed noise estimation method with an existing noise reduction method confirms that the proposed method outperforms traditional methods. PMID:29596335

  17. Poisson-Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain.

    Science.gov (United States)

    Lee, Sangyoon; Lee, Min Seok; Kang, Moon Gi

    2018-03-29

    The noise distribution of images obtained by X-ray sensors in low-dosage situations can be analyzed using the Poisson and Gaussian mixture model. Multiscale conversion is one of the most popular noise reduction methods used in recent years. Estimation of the noise distribution of each subband in the multiscale domain is the most important factor in performing noise reduction, with non-subsampled contourlet transform (NSCT) representing an effective method for scale and direction decomposition. In this study, we use artificially generated noise to analyze and estimate the Poisson-Gaussian noise of low-dose X-ray images in the NSCT domain. The noise distribution of the subband coefficients is analyzed using the noiseless low-band coefficients and the variance of the noisy subband coefficients. The noise-after-transform also follows a Poisson-Gaussian distribution, and the relationship between the noise parameters of the subband and the full-band image is identified. We then analyze noise of actual images to validate the theoretical analysis. Comparison of the proposed noise estimation method with an existing noise reduction method confirms that the proposed method outperforms traditional methods.

  18. Noise analysis of genome-scale protein synthesis using a discrete computational model of translation

    Energy Technology Data Exchange (ETDEWEB)

    Racle, Julien; Hatzimanikatis, Vassily, E-mail: vassily.hatzimanikatis@epfl.ch [Laboratory of Computational Systems Biotechnology, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Swiss Institute of Bioinformatics (SIB), CH-1015 Lausanne (Switzerland); Stefaniuk, Adam Jan [Laboratory of Computational Systems Biotechnology, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2015-07-28

    Noise in genetic networks has been the subject of extensive experimental and computational studies. However, very few of these studies have considered noise properties using mechanistic models that account for the discrete movement of ribosomes and RNA polymerases along their corresponding templates (messenger RNA (mRNA) and DNA). The large size of these systems, which scales with the number of genes, mRNA copies, codons per mRNA, and ribosomes, is responsible for some of the challenges. Additionally, one should be able to describe the dynamics of ribosome exchange between the free ribosome pool and those bound to mRNAs, as well as how mRNA species compete for ribosomes. We developed an efficient algorithm for stochastic simulations that addresses these issues and used it to study the contribution and trade-offs of noise to translation properties (rates, time delays, and rate-limiting steps). The algorithm scales linearly with the number of mRNA copies, which allowed us to study the importance of genome-scale competition between mRNAs for the same ribosomes. We determined that noise is minimized under conditions maximizing the specific synthesis rate. Moreover, sensitivity analysis of the stochastic system revealed the importance of the elongation rate in the resultant noise, whereas the translation initiation rate constant was more closely related to the average protein synthesis rate. We observed significant differences between our results and the noise properties of the most commonly used translation models. Overall, our studies demonstrate that the use of full mechanistic models is essential for the study of noise in translation and transcription.

  19. Current development in data acquision and processing system for reactor noise analysis in PUSPATI

    International Nuclear Information System (INIS)

    Mohamad Amin Sharifuldin Salleh.

    1986-11-01

    A data acquisition and processing system for reactor noise analysis is described. It consists of four-channel isolation amplifier, a seven-channel DC amplifier, a four-channel analog to digital converter, analog filters, a microcomputer system and a plotter. This system is being applied to investigate the reactor dynamics of the PUSPATI TRIGA MK II reactor. (author)

  20. Noise and ac impedance analysis of ion transfer kinetics at the micro liquid/liquid interface

    Czech Academy of Sciences Publication Activity Database

    Josypčuk, Oksana; Holub, Karel; Mareček, Vladimír

    2015-01-01

    Roč. 56, JUL 2015 (2015), s. 43-45 ISSN 1388-2481 R&D Projects: GA ČR GA13-04630S Institutional support: RVO:61388955 Keywords : noise analysis * liquid/liquid interface * ion transfer kinetics Subject RIV: CG - Electrochemistry Impact factor: 4.569, year: 2015

  1. Mechanical surveillance of the internal structures on the French PWRs by noise analysis

    International Nuclear Information System (INIS)

    Puyal, C.

    1983-01-01

    In service observation of structures, materials and systems in PWRs is one of the major preoccupations of EDF. Methods and means have been developed and put into service in order to achieve this goal. This paper deals with the surveillance of primary systems, using the technique of noise analysis [fr

  2. Non-Enzymatic Wearable Sensor for Electrochemical Analysis of Perspiration Glucose.

    Science.gov (United States)

    Zhu, Xiaofei; Ju, Yinhui; Chen, Jian; Liu, Deye; Liu, Hong

    2018-05-16

    We report a non-enzymatic wearable sensor for electrochemical analysis of perspiration glucose. Multi-potential steps are applied on a Au electrode, including a high negative pretreatment potential step for proton reduction which produc-es a localized alkaline condition, a moderate potential step for electrocatalytic oxidation of glucose under the alkaline condi-tion, and a positive potential step to clean and reactivate the electrode surface for the next detection. Fluorocarbon-based materials were coated on the Au electrode for improving the selectivity and robustness of the sensor. A fully integrated wrist-band is developed for continuous real-time monitoring of perspiration glucose during physical activities, and uploading the test result to a Smartphone App via Bluetooth.

  3. Integrating Paper Chromatography with Electrochemical Detection for the Trace Analysis of TNT in Soil

    Directory of Open Access Journals (Sweden)

    Patrick Ryan

    2015-07-01

    Full Text Available We report on the development of an electrochemical probe for the trace analysis of 2,4,6-trinitrotoluene (TNT in soil samples. The probe is a combination of graphite electrodes, filter paper, with ethylene glycol and choline chloride as the solvent/electrolyte. Square wave chromatovoltammograms show the probes have a sensitivity for TNT of 0.75 nA/ng and a limit of detection of 100 ng. In addition, by taking advantage of the inherent paper chromatography step, TNT can be separated in both time and cathodic peak potential from 4-amino-dinitrotolene co-spotted on the probe or in soil samples with the presence of methyl parathion as a possible interferent.

  4. RNA aptamer-based electrochemical biosensor for selective and label-free analysis of dopamine

    DEFF Research Database (Denmark)

    Farjami, Elahe; Campos, Rui; Nielsen, Jesper Sejrup

    2013-01-01

    , including dopamine precursors and metabolites and other neurotransmitters (NT). Here we report an electrochemical RNA aptamer-based biosensor for analysis of dopamine in the presence of other NT. The biosensor exploits a specific binding of dopamine by the RNA aptamer, immobilized at a cysteamine......, norepinephrine, 3,4-dihydroxy-phenylalanine (l-DOPA), 3,4-dihydroxyphenylacetic acid (DOPAC), methyldopamine, and tyramine, which gave negligible signals under conditions of experiments (electroanalysis at 0.185 V vs Ag/AgCl). The interference from ascorbic and uric acids was eliminated by application...... as a general strategy not to restrict the conformational freedom and binding properties of surface-bound aptamers and, thus, be applicable for the development of other aptasensors...

  5. Fabrication of a Microfluidic Device with Boron-doped Diamond Electrodes for Electrochemical Analysis

    International Nuclear Information System (INIS)

    Watanabe, Takeshi; Shibano, Shuhei; Maeda, Hideto; Sugitani, Ai; Katayama, Michinobu; Matsumoto, Yoshinori; Einaga, Yasuaki

    2016-01-01

    A prototype microfluidic device using boron-doped diamond (BDD) electrodes patterned on an alumina chip was designed and fabricated. Electrochemical microfluidic devices have advantages in that the amount of sample required is small, the measurement throughput is high, different functions can be integrated on a single device, and they are highly durable. In using the device for the flow injection analysis of oxalic acid, the application of a brief conditioning step ensured that the reproducibility of the current signal was excellent. Furthermore, the fabricated system also performed as a prototype of “elimination-detection flow system”, in which interfering species are eliminated using “elimination electrodes” prior to the species reaching the “detection electrode”. The fabricated device reduced the current due to interfering species by 78%. Designs of devices to improve this efficiency are also discussed.

  6. A study of power fluctuations in a flip fuel reactor using the technique of noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Randall, J D; Wood, G C; Edwards, M A [Texas A and M University (United States)

    1974-07-01

    The Nuclear Science Center Reactor at Texas A and M University has experienced minor power fluctuations when operating at or near 1 megawatt. A noise analysis system was developed to investigate these fluctuations assuming that void formation, primarily due to nucleate boiling, was the cause. Experiments were carried out to correlate boiling noise with power level, fission product poisoning, and pool temperature. Results show that void formation in the core is the probable cause of the fluctuations with the onset of boiling occurring at 400 Kw. Data was also obtained that indicated the presence of boiling in a standard TRIGA core. (author)

  7. Analysis of the spectrum of noise in Gamma cameras and correction of the structural noise associated with collimator

    International Nuclear Information System (INIS)

    Ramos Pacho, J. A.; Montes Fuentes, C.; Verde Velasco, J. M.; Delgado Aparicio, J. M.; Perez Alvarez, M. e.; Gomez Gonzalez, N.; Cons Perez, N.; Garcia Repiso, S.; Saez Beltran, M.; Gomez Llorente, P. L.

    2013-01-01

    Noise is one of the characteristics main of the images obtained in Nuclear Medicine, so using mechanisms that reduce the presence of this we would, with the same number of accounts and therefore with the same activity, harnessing the power of the computer resolution and extract more image information. With this objective, this study describes the acquisition and processing of uniform images using that analysed the spectral components of the noise, and is a filter that allows to attenuate it. (Author)

  8. The analysis of transient noise of PCB P/G network based on PI/SI co-simulation

    Science.gov (United States)

    Haohang, Su

    2018-02-01

    With the frequency of the space camera become higher than before, the power noise of the imaging electronic system become the important factor. Much more power noise would disturb the transmissions signal, and even influence the image sharpness and system noise. "Target impedance method" is one of the traditional design method of P/G network (power and ground network), which is shorted of transient power noise analysis and often made "over design". In this paper, a new design method of P/G network is provided which simulated by PI/SI co-simulation. The transient power noise can be simulated and then applied in the design of noise reduction, thus effectively controlling the change of the noise in the P/G network. The method can efficiently control the number of adding decoupling capacitor, and is very efficient and feasible to keep the power integrity.

  9. A noise reduction technique based on nonlinear kernel function for heart sound analysis.

    Science.gov (United States)

    Mondal, Ashok; Saxena, Ishan; Tang, Hong; Banerjee, Poulami

    2017-02-13

    The main difficulty encountered in interpretation of cardiac sound is interference of noise. The contaminated noise obscures the relevant information which are useful for recognition of heart diseases. The unwanted signals are produced mainly by lungs and surrounding environment. In this paper, a novel heart sound de-noising technique has been introduced based on a combined framework of wavelet packet transform (WPT) and singular value decomposition (SVD). The most informative node of wavelet tree is selected on the criteria of mutual information measurement. Next, the coefficient corresponding to the selected node is processed by SVD technique to suppress noisy component from heart sound signal. To justify the efficacy of the proposed technique, several experiments have been conducted with heart sound dataset, including normal and pathological cases at different signal to noise ratios. The significance of the method is validated by statistical analysis of the results. The biological information preserved in de-noised heart sound (HS) signal is evaluated by k-means clustering algorithm and Fit Factor calculation. The overall results show that proposed method is superior than the baseline methods.

  10. Process sensors characterization based on noise analysis technique and artificial intelligence

    International Nuclear Information System (INIS)

    Mesquita, Roberto N. de; Perillo, Sergio R.P.; Santos, Roberto C. dos

    2005-01-01

    The time response of pressure and temperature sensors from the Reactor Protection System (RPS) is a requirement that must be satisfied in nuclear power plants, furthermore is an indicative of its degradation and its remaining life. The nuclear power industry and others have been eager to implement smart sensor technologies and digital instrumentation concepts to reduce manpower and effort currently spent on testing and calibration. Process parameters fluctuations during normal operation of a reactor are caused by random variations in neutron flux, heat transfer and other sources. The output sensor noise can be considered as the response of the system to an input representing the statistical nature of the underlying process which can be modeled using a time series model. Since the noise signal measurements are influenced by many factors, such as location of sensors, extraneous noise interference, and randomness in temperature and pressure fluctuation - the quantitative estimate of the time response using autoregressive noise modeling is subject to error. This technique has been used as means of sensor monitoring. In this work a set of pressure sensors installed in one experimental loop adapted from a flow calibration setup is used to test and analyze signals in a new approach using artificial intelligence techniques. A set of measurements of dynamic signals in different experimental conditions is used to distinguish and identify underlying process sources. A methodology that uses Blind Separation of Sources with a neural networks scheme is being developed to improve time response estimate reliability in noise analysis. (author)

  11. Process sensors characterization based on noise analysis technique and artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Roberto N. de; Perillo, Sergio R.P.; Santos, Roberto C. dos [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rnavarro@ipen.br; sperillo@ipen.br; rcsantos@ipen.br

    2005-07-01

    The time response of pressure and temperature sensors from the Reactor Protection System (RPS) is a requirement that must be satisfied in nuclear power plants, furthermore is an indicative of its degradation and its remaining life. The nuclear power industry and others have been eager to implement smart sensor technologies and digital instrumentation concepts to reduce manpower and effort currently spent on testing and calibration. Process parameters fluctuations during normal operation of a reactor are caused by random variations in neutron flux, heat transfer and other sources. The output sensor noise can be considered as the response of the system to an input representing the statistical nature of the underlying process which can be modeled using a time series model. Since the noise signal measurements are influenced by many factors, such as location of sensors, extraneous noise interference, and randomness in temperature and pressure fluctuation - the quantitative estimate of the time response using autoregressive noise modeling is subject to error. This technique has been used as means of sensor monitoring. In this work a set of pressure sensors installed in one experimental loop adapted from a flow calibration setup is used to test and analyze signals in a new approach using artificial intelligence techniques. A set of measurements of dynamic signals in different experimental conditions is used to distinguish and identify underlying process sources. A methodology that uses Blind Separation of Sources with a neural networks scheme is being developed to improve time response estimate reliability in noise analysis. (author)

  12. Spectral data de-noising using semi-classical signal analysis: application to localized MRS

    KAUST Repository

    Laleg-Kirati, Taous-Meriem

    2016-09-05

    In this paper, we propose a new post-processing technique called semi-classical signal analysis (SCSA) for MRS data de-noising. Similar to Fourier transformation, SCSA decomposes the input real positive MR spectrum into a set of linear combinations of squared eigenfunctions equivalently represented by localized functions with shape derived from the potential function of the Schrodinger operator. In this manner, the MRS spectral peaks represented as a sum of these \\'shaped like\\' functions are efficiently separated from noise and accurately analyzed. The performance of the method is tested by analyzing simulated and real MRS data. The results obtained demonstrate that the SCSA method is highly efficient in localized MRS data de-noising and allows for an accurate data quantification.

  13. Spectral data de-noising using semi-classical signal analysis: application to localized MRS

    KAUST Repository

    Laleg-Kirati, Taous-Meriem; Zhang, Jiayu; Achten, Eric; Serrai, Hacene

    2016-01-01

    In this paper, we propose a new post-processing technique called semi-classical signal analysis (SCSA) for MRS data de-noising. Similar to Fourier transformation, SCSA decomposes the input real positive MR spectrum into a set of linear combinations of squared eigenfunctions equivalently represented by localized functions with shape derived from the potential function of the Schrodinger operator. In this manner, the MRS spectral peaks represented as a sum of these 'shaped like' functions are efficiently separated from noise and accurately analyzed. The performance of the method is tested by analyzing simulated and real MRS data. The results obtained demonstrate that the SCSA method is highly efficient in localized MRS data de-noising and allows for an accurate data quantification.

  14. Comparative analysis of chosen transforms in the context of de-noising harmonic signals

    Directory of Open Access Journals (Sweden)

    Artur Zacniewski

    2015-09-01

    Full Text Available In the article, comparison of popular transforms used i.a. in denoising harmonical signals was presented. The division of signals submitted to mathematical analysis was shown and chosen transforms such as Short Time Fourier Transform, Wigner-Ville Distribution, Wavelet Transform and Discrete Cosine Transform were presented. Harmonic signal with white noise added was submitted for research. During research, the parameters of noise were changed to analyze the effects of using particular transform on noised signal. The importance of right choice for transform and its parameters (different for particular kind of transform was shown. Small changes in parameters or different functions used in transform can lead to considerably different results.[b]Keywords[/b]: denoising of harmonical signals, wavelet transform, discrete cosine transform, DCT

  15. Analysis of noise in energy-dispersive spectrometers using time-domain methods

    CERN Document Server

    Goulding, F S

    2002-01-01

    This paper presents an integrated time domain approach to the optimization of the signal-to-noise ratio in all spectrometer systems that contain a detector that converts incoming quanta of radiation into electrical pulse signals that are amplified and shaped by an electronic pulse shaper. It allows analysis of normal passive pulse shapers as well as time-variant systems where switching of shaping elements occurs in synchronism with the signal. It also deals comfortably with microcalorimeters (sometimes referred to as bolometers), where noise-determining elements, such as the temperature-sensing element's resistance and temperature, change with time in the presence of a signal. As part of the purely time-domain approach, a new method of calculating the Johnson noise in resistors using only the statistics of electron motion is presented. The result is a time-domain analog of the Nyquist formula.

  16. Room acoustic analysis of blower unit and noise control plan in the typical steel industry

    Directory of Open Access Journals (Sweden)

    2013-02-01

    Full Text Available Introduction: In the steel industry,air blowers used to supply compressed air are considered as sources of annoying noise. This study aims to acoustics analysis of theairblower workroomand sound source characteristics in order to present noise controlmeasuresinthe steel industry. .Material and Method: Measurement of noiselevel and its frequency analysis was performed usingsound levelmetermodelof CASELLA-Cell.450. Distribution of noise level in the investigated workroom in form of noise map was provided using Surfer software. In addition, acoustic analysis of workroom and control room was performed in view point of soundabsorption andinsulation. Redesignofdoor and window of controlroom and installation of soundabsorbing materialson theceiling of the workroom were proposed and the efficiency of these interventionswasestimated. .Result: The totalsound pressurelevelin the blower workroom was 95.4 dB(L and the dominant frequency was 2000Hz. Sound pressure level inside the room control was 80.1dB(A. The average absorption coefficient and reverberation time in the blower workroom was estimated equal to 0.082 Sab.m2 and 3.9 seconds respectively. These value in control room was 0.04 Sab.m2 and 3/4 seconds respectively. In control room, sound transmission loss between the two parts of the wall dividing was 13.7 dB(A. The average of noise dose in blower operators was 230%. With the installation of sound absorber on ceiling of workroom, average of absorption coefficient can increase to 0.33 Sab.m2 and sound transmission loss of the new designed door and window was estimated equal to 20dB. . Conclusion: The main cause of noise leakage in the control room was insufficient insulation properties of door and windows. By replacing the door and window and installation of sound absorbing on ceiling of workroom, the noise dose can reduce to 49.6%. New Improved door and window of control room can reduce noise dose to 69.65% solely.

  17. Application of noise analysis for the study of core local instability at Forsmark 1

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1997-10-01

    Core local instability was recently experienced at Forsmark 1 BWR. The event has been studied by applying noise analysis to data collected in January 1997 for the stability test. The result indicated that there was a region in the left corner of the core which was subject to instability due to neutronic and thermal-hydraulic coupling. The result of the noise analysis suggested two types of disturbance source, one in the vicinity of the detector string LPRM10 having resonant oscillation at 0.5 Hz and another relatively wide band noise in the neighbourhood of LPRM18. Three hypotheses have been examined as the possible cause, operational factor, abnormal fuel assembly, and wide band low frequency disturbance. Although the real cause has not been made clear from the noise analysis, it is likely that the operational factor played an important role as the cause. Further investigations are expected to be performed in the future. In order to detect the local instability it is important to have a stability monitor with a capability of monitoring a sufficient number of LPRMs so as to cover the whole core. This is important since local instability is a type of anomaly which should not occur during reactor operation

  18. Dynamic analysis of the Nova Target Chamber to assess alignment errors due to ambient noise

    International Nuclear Information System (INIS)

    McCallen, D.B.; Murray, R.C.

    1984-01-01

    We performed a study to determine the dynamic behavior of the Nova Target Chamber. We conducted a free vibration analysis to determine the natural frequencies of vibration and the corresponding modeshapes of the target chamber. Utilizing the free vibration results, we performed forced vibration analysis to predict the displacements of the chamber due to ambient vibration. The input support motion for the forced vibration analysis was defined by a white noise acceleration spectrum which was based on previous measurements of ground noise near the Nova site. A special purpose computer program was prepared to process the results of the forced vibration analysis. The program yields distances by which the lines of sight of the various laser beams miss the target as a result of ambient vibrations. We also performed additional estimates of miss distance to provide bounds on the results. A description of the finite element model of the chamber, the input spectrum, and the results of the analyses are included

  19. Aspect-dependent radiated noise analysis of an underway autonomous underwater vehicle.

    Science.gov (United States)

    Gebbie, John; Siderius, Martin; Allen, John S

    2012-11-01

    This paper presents an analysis of the acoustic emissions emitted by an underway REMUS-100 autonomous underwater vehicle (AUV) that were obtained near Honolulu Harbor, HI using a fixed, bottom-mounted horizontal line array (HLA). Spectral analysis, beamforming, and cross-correlation facilitate identification of independent sources of noise originating from the AUV. Fusion of navigational records from the AUV with acoustic data from the HLA allows for an aspect-dependent presentation of calculated source levels of the strongest propulsion tone.

  20. Corrected Statistical Energy Analysis Model for Car Interior Noise

    Directory of Open Access Journals (Sweden)

    A. Putra

    2015-01-01

    Full Text Available Statistical energy analysis (SEA is a well-known method to analyze the flow of acoustic and vibration energy in a complex structure. For an acoustic space where significant absorptive materials are present, direct field component from the sound source dominates the total sound field rather than a reverberant field, where the latter becomes the basis in constructing the conventional SEA model. Such environment can be found in a car interior and thus a corrected SEA model is proposed here to counter this situation. The model is developed by eliminating the direct field component from the total sound field and only the power after the first reflection is considered. A test car cabin was divided into two subsystems and by using a loudspeaker as a sound source, the power injection method in SEA was employed to obtain the corrected coupling loss factor and the damping loss factor from the corrected SEA model. These parameters were then used to predict the sound pressure level in the interior cabin using the injected input power from the engine. The results show satisfactory agreement with the directly measured SPL.

  1. Noise source analysis of nuclear ship Mutsu plant using multivariate autoregressive model

    International Nuclear Information System (INIS)

    Hayashi, K.; Shimazaki, J.; Shinohara, Y.

    1996-01-01

    The present study is concerned with the noise sources in N.S. Mutsu reactor plant. The noise experiments on the Mutsu plant were performed in order to investigate the plant dynamics and the effect of sea condition and and ship motion on the plant. The reactor noise signals as well as the ship motion signals were analyzed by a multivariable autoregressive (MAR) modeling method to clarify the noise sources in the reactor plant. It was confirmed from the analysis results that most of the plant variables were affected mainly by a horizontal component of the ship motion, that is the sway, through vibrations of the plant structures. Furthermore, the effect of ship motion on the reactor power was evaluated through the analysis of wave components extracted by a geometrical transform method. It was concluded that the amplitude of the reactor power oscillation was about 0.15% in normal sea condition, which was small enough for safe operation of the reactor plant. (authors)

  2. BAYESIAN ANALYSIS OF WHITE NOISE LEVELS IN THE FIVE-YEAR WMAP DATA

    International Nuclear Information System (INIS)

    Groeneboom, N. E.; Eriksen, H. K.; Gorski, K.; Huey, G.; Jewell, J.; Wandelt, B.

    2009-01-01

    We develop a new Bayesian method for estimating white noise levels in CMB sky maps, and apply this algorithm to the five-year Wilkinson Microwave Anisotropy Probe (WMAP) data. We assume that the amplitude of the noise rms is scaled by a constant value, α, relative to a pre-specified noise level. We then derive the corresponding conditional density, P(α | s, C l , d), which is subsequently integrated into a general CMB Gibbs sampler. We first verify our code by analyzing simulated data sets, and then apply the framework to the WMAP data. For the foreground-reduced five-year WMAP sky maps and the nominal noise levels initially provided in the five-year data release, we find that the posterior means typically range between α = 1.005 ± 0.001 and α = 1.010 ± 0.001 depending on differencing assembly, indicating that the noise level of these maps are biased low by 0.5%-1.0%. The same problem is not observed for the uncorrected WMAP sky maps. After the preprint version of this letter appeared on astro-ph., the WMAP team has corrected the values presented on their web page, noting that the initially provided values were in fact estimates from the three-year data release, not from the five-year estimates. However, internally in their five-year analysis the correct noise values were used, and no cosmological results are therefore compromised by this error. Thus, our method has already been demonstrated in practice to be both useful and accurate.

  3. Noise suppression by noise

    OpenAIRE

    Vilar, J. M. G. (José M. G.), 1972-; Rubí Capaceti, José Miguel

    2001-01-01

    We have analyzed the interplay between an externally added noise and the intrinsic noise of systems that relax fast towards a stationary state, and found that increasing the intensity of the external noise can reduce the total noise of the system. We have established a general criterion for the appearance of this phenomenon and discussed two examples in detail.

  4. The signal-to-noise analysis of the Little-Hopfield model revisited

    International Nuclear Information System (INIS)

    Bolle, D; Blanco, J Busquets; Verbeiren, T

    2004-01-01

    Using the generating functional analysis an exact recursion relation is derived for the time evolution of the effective local field of the fully connected Little-Hopfield model. It is shown that, by leaving out the feedback correlations arising from earlier times in this effective dynamics, one precisely finds the recursion relations usually employed in the signal-to-noise approach. The consequences of this approximation as well as the physics behind it are discussed. In particular, it is pointed out why it is hard to notice the effects, especially for model parameters corresponding to retrieval. Numerical simulations confirm these findings. The signal-to-noise analysis is then extended to include all correlations, making it a full theory for dynamics at the level of the generating functional analysis. The results are applied to the frequently employed extremely diluted (a)symmetric architectures and to sequence processing networks

  5. Development of electronic system for reactivity measurement and reactor noise analysis

    International Nuclear Information System (INIS)

    Strohl, Claude Emile; Soares, Adalberto Jose

    1996-01-01

    In nuclear power reactors, the neutron detector signal is dependent of the number of fissions and the reactor power level. The detector signal can be divided into two components; a DC component, proportional to the average value and an AC component, which is the fluctuating part superimposed to the DC component. The analysis of the fluctuating part of the signal is called noise analysis and allow us to investigate phenomena occurring within the reactor vessel, such as vibration of fuels elements and coolant density, temperature, pressure and flow changes. On the other hand, the measure of the static DC part allow us to measure the local power density. This paper describes the development of a personal computer based signal conditioning card that, together with a personal computer commercial data acquisition card, can be used for noise analysis measurements and reactivity measurements of signals coming from ionization chambers or SPD's. (author)

  6. Development of an electrometer/amplifier and filter set for analysis of reactor noise

    International Nuclear Information System (INIS)

    Strohl, Claude Emile

    1996-01-01

    In nuclear power reactors, the neutron detector signal is dependent on the number of fissions and the reactor power level. The detector signal can be divided into two components: a D C component, proportional to the average value and an A C component, which is the fluctuating part superimposed to the D C component. The analysis of the fluctuating part of the signal is called noise analysis and allow us to investigate phenomena occurring within the reactor vessel, such as vibrational of fuel elements and coolant density, temperature, pressure and flow changes. On the other hand, the measure of the static D C part allows us to measure the local power density. This work describes the development of a personal computer based signal conditioning card that, together with a personal computer commercial data acquisition card, can be used for noise analysis and reactivity measurements of signals coming from ionization chambers or SPD's. (author)

  7. Damping layout optimization for ship's cabin noise reduction based on statistical energy analysis

    Directory of Open Access Journals (Sweden)

    WU Weiguo

    2017-08-01

    Full Text Available An optimization analysis study concerning the damping control of ship's cabin noise was carried out in order to improve the effect and reduce the weight of damping. Based on the Statistical Energy Analysis (SEA method, a theoretical deduction and numerical analysis of the first-order sensitivity analysis of the A-weighted sound pressure level concerning the damping loss factor of the subsystem were carried out. On this basis, a mathematical optimization model was proposed and an optimization program developed. Next, the secondary development of VA One software was implemented through the use of MATLAB, while the cabin noise damping control layout optimization system was established. Finally, the optimization model of the ship was constructed and numerical experiments of damping control optimization conducted. The damping installation region was divided into five parts with different damping thicknesses. The total weight of damping was set as an objective function and the A-weighted sound pressure level of the target cabin was set as a constraint condition. The best damping thickness was obtained through the optimization program, and the total damping weight was reduced by 60.4%. The results show that the damping noise reduction effect of unit weight is significantly improved through the optimization method. This research successfully solves the installation position and thickness selection problems in the acoustic design of damping control, providing a reliable analysis method and guidance for the design.

  8. Reactor noise analysis based on nonlinear dynamic theory - application to power oscillation

    International Nuclear Information System (INIS)

    Suzudo, Tomoaki

    1993-01-01

    The information dimension is one of the simplest quantities that can be used to determine the asymptotic motion of the time evolution of a nonlinear system. The application of this quantity to reactor noise analysis is proposed, and the possibility of its application to power oscillation analysis is examined. The information dimension of this regime is equal to the number of independent oscillating modes, which is an intuitive physical variable. Time series data from computer experiments and experiments with an actual physical system are used for the analysis. The results indicate that the method is useful for a detailed analysis of reactor power oscillation

  9. Noise resistance applied to the study of zinc rich paints

    International Nuclear Information System (INIS)

    Espada Recarey, L.; Sanchez Bermudez, A.; Urrejola Madrinan, S.; Bouzada Alvela, F.

    2001-01-01

    Electrochemical Noise has been one of the more useful analysis methods to the study the corrosion processes due to the fact that it is simple and cheap. The objective of this work is to check the efficiency of this technique when it is applied to the study of Rich Zinc Paints and specifically the Noise Resistance parameter which is very efficiency to study metal-electrolyte systems. Then this technique was applied to Rich Zinc Paints systems of which we have already information by means of electrochemical impedance spectroscopy. The outcomes of this paper show the efficiency of applying Noise Resistance technique to explain the behavior of this kind of systems. (Author) 18 refs

  10. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  11. Statistical Analysis of Coherent Ultrashort Light Pulse CDMA With Multiple Optical Amplifiers Using Additive Noise Model

    Science.gov (United States)

    Jamshidi, Kambiz; Salehi, Jawad A.

    2005-05-01

    This paper describes a study of the performance of various configurations for placing multiple optical amplifiers in a typical coherent ultrashort light pulse code-division multiple access (CULP-CDMA) communication system using the additive noise model. For this study, a comprehensive performance analysis was developed that takes into account multiple-access noise, noise due to optical amplifiers, and thermal noise using the saddle-point approximation technique. Prior to obtaining the overall system performance, the input/output statistical models for different elements of the system such as encoders/decoders,star coupler, and optical amplifiers were obtained. Performance comparisons between an ideal and lossless quantum-limited case and a typical CULP-CDMA with various losses exhibit more than 30 dB more power requirement to obtain the same bit-error rate (BER). Considering the saturation effect of optical amplifiers, this paper discusses an algorithm for amplifiers' gain setting in various stages of the network in order to overcome the nonlinear effects on signal modulation in optical amplifiers. Finally, using this algorithm,various configurations of multiple optical amplifiers in CULP-CDMA are discussed and the rules for the required optimum number of amplifiers are shown with their corresponding optimum locations to be implemented along the CULP-CDMA system.

  12. Measurement and analysis of the noise radiated by low Mach numbers centrifugal blowers

    Science.gov (United States)

    Yeager, D. M.; Lauchle, G. C.

    1987-11-01

    The broad band, aerodynamically generated noise in low tip-speed Mach number, centrifugal air moving devices is investigated. An interdisciplinary approach was taken which involved investigation of the aerodynamic and acoustic fields, and their mutual relationship. The noise generation process was studied using two experimental vehicles: (1) a scale model of a homologous family of centrifugal blowers typical of those used to cool computer and business equipment, and (2) a single blade from a centrifugal blower impeller which was placed in a known, controllable flow field. The radiation characteristics of the model blower were investigated by measuring the acoustic intensity distribution near the blower inlet and comparing it with the intensity near the inlet to an axial flow fan. Aerodynamic studies of the flow field in the inlet and at the discharge to the rotating impeller were used to assess the mean flow distribution through the impeller blade channels and to identify regions of excessive turbulence near the rotating blade row. New frequency-domain expressions for the correlation area and dipole source strength per unit area on a surface immersed in turbulence were developed which can be used to characterize the noise generation process over a rigid surface immersed in turbulence. An investigation of the noise radiated from the single, isolated airfoil (impeller blade) was performed using modern correlation and spectral analysis techniques.

  13. Noise-shaping all-digital phase-locked loops modeling, simulation, analysis and design

    CERN Document Server

    Brandonisio, Francesco

    2014-01-01

    This book presents a novel approach to the analysis and design of all-digital phase-locked loops (ADPLLs), technology widely used in wireless communication devices. The authors provide an overview of ADPLL architectures, time-to-digital converters (TDCs) and noise shaping. Realistic examples illustrate how to analyze and simulate phase noise in the presence of sigma-delta modulation and time-to-digital conversion. Readers will gain a deep understanding of ADPLLs and the central role played by noise-shaping. A range of ADPLL and TDC architectures are presented in unified manner. Analytical and simulation tools are discussed in detail. Matlab code is included that can be reused to design, simulate and analyze the ADPLL architectures that are presented in the book.   • Discusses in detail a wide range of all-digital phase-locked loops architectures; • Presents a unified framework in which to model time-to-digital converters for ADPLLs; • Explains a procedure to predict and simulate phase noise in oscil...

  14. Analysis of regularized inversion of data corrupted by white Gaussian noise

    International Nuclear Information System (INIS)

    Kekkonen, Hanne; Lassas, Matti; Siltanen, Samuli

    2014-01-01

    Tikhonov regularization is studied in the case of linear pseudodifferential operator as the forward map and additive white Gaussian noise as the measurement error. The measurement model for an unknown function u(x) is m(x) = Au(x) + δ ε (x), where δ > 0 is the noise magnitude. If ε was an L 2 -function, Tikhonov regularization gives an estimate T α (m) = u∈H r arg min { ||Au-m|| L 2 2 + α||u|| H r 2 } for u where α = α(δ) is the regularization parameter. Here penalization of the Sobolev norm ||u|| H r covers the cases of standard Tikhonov regularization (r = 0) and first derivative penalty (r = 1). Realizations of white Gaussian noise are almost never in L 2 , but do belong to H s with probability one if s < 0 is small enough. A modification of Tikhonov regularization theory is presented, covering the case of white Gaussian measurement noise. Furthermore, the convergence of regularized reconstructions to the correct solution as δ → 0 is proven in appropriate function spaces using microlocal analysis. The convergence of the related finite-dimensional problems to the infinite-dimensional problem is also analysed. (paper)

  15. Analysis of noise on construction sites of high-rise buildings.

    Science.gov (United States)

    Barkokébas, Béda; Vasconcelos, Bianca M; Lago, Eliane Maria G; Alcoforador, Aline Fabiana P

    2012-01-01

    In the civil construction industry sector, it has been observed that the increasing use of machines has made tasks noisier and consequently caused hearing loss and had other adverse effects on workers. The objective of this study was to identify and assess the physical risks of noise present in activities undertaken in a construction company in order to propose control measures which will contribute to the management of health and safety within the company's organization. The methodology applied was based on verifying the characteristics of exposure to noise on construction sites, from an observation of sources which generated noise and making measurements of sound pressure levels emitted by these sources. The data was then analyzed and compared with the recommended performance levels established in control measures. As a result, it was found that some machines and equipment used in civil construction often generate noise above the acceptable levels and as such, in these cases, various control measures have been proposed. It is believed that the use of management techniques is the most effective way to assess risk and to implement the preventive and corrective actions proposed, and allows for the analysis of sound pressure levels on an ongoing basis.

  16. Electrochemical Study of Delta-9-Tetrahydrocannabinol by Cyclic Voltammetry Using Screen Printed Electrode, Improvements in Forensic Analysis

    Directory of Open Access Journals (Sweden)

    Marco Antonio BALBINO

    2016-12-01

    Full Text Available Rapid screening of seized drugs is a continuing problem for governmental laboratories and customs agents. Recently new and cheaper methods based on electrochemical sensing have been developed for the detection of illicit drugs. Screen printed electrodes are particularly useful in this regard and can provide excellent sensitivity. In this study, a carbon screen printed electrode for the voltammetric analysis of D9-THC was developed. The analysis was performed using cyclic voltammetry with 0.15 mol×L-1 potassium nitrate as a supporting electrolyte. In the analysis, a D9-THC standard solution was added to the surface electrode by a drop coating method. A study of scan rate, time of pre-concentration, and concentration influence parameters showed versatility during the investigation. The high sensitivity, quantitative capability and low limit of detection (1.0 µmol×L-1 demonstrate that this electrochemical method should be an attractive alternative in forensic investigations of seized samples.

  17. Measures of the zero power nuclear reactor's kinetic parameters with application of noise analysis

    International Nuclear Information System (INIS)

    Martins, F.R.

    1992-01-01

    The purpose of this work was to establish an experimental technique based on noise analysis for measuring the ratio of kinetic parameters β/ Λ and the power of the Zero Power Nuclear Reactor IPEN-MB 01. A through study of the microscopic and macroscopic noise analysis techniques has been carried out. The Langevin technique and the point kinetic model were chosen to describe the stochastic phenomena that occur in the zero power reactor. Measurements have been made using two compensated ionization chambers localized in the water reflector at symmetric positions in order to minimize spatial effects on the neutron flux fluctuation. Power calibrations based on the low frequency plateau of the cross-power spectral density has also been carried out. (author)

  18. Identification of flow patterns by neutron noise analysis during actual coolant boiling in thin rectangular channels

    International Nuclear Information System (INIS)

    Kozma, R.; van Dam, H.; Hoogenboom, J.E.

    1992-01-01

    The primary objective of this paper is to introduce results of coolant boiling experiments in a simulated materials test reactor-type fuel assembly with plate fuel in an actual reactor environment. The experiments have been performed in the Hoger Onderwijs Reactor (HOR) research reactor at the Interfaculty Reactor Institute, Delft, The Netherlands. In the analysis, noise signals of self-powered neutron detectors located in the neighborhood of the boiling region and thermocouple in the channel wall and in the coolant are used. Flow patterns in the boiling coolant have been identified by means of analysis of probability density functions and power spectral densities of neutron noise. It is shown that boiling has an oscillating character due to partial channel blockage caused by steam slugs generated periodically between the plates. The observed phenomenon can serve as a basis for a boiling detection method in reactors with plate-type fuels

  19. A time-variant analysis of the 1/f^(2) phase noise in CMOS parallel LC-Tank quadrature oscillators

    DEFF Research Database (Denmark)

    Andreani, Pietro

    2006-01-01

    This paper presents a study of 1/f2 phase noise in quadrature oscillators built by connecting two differential LC-tank oscillators in a parallel fashion. The analysis clearly demonstrates the necessity of adopting a time-variant theory of phase noise, where a more simplistic, time...

  20. On-Chip Evaluation of DNA Methylation with Electrochemical Combined Bisulfite Restriction Analysis Utilizing a Carbon Film Containing a Nanocrystalline Structure.

    Science.gov (United States)

    Kurita, Ryoji; Yanagisawa, Hiroyuki; Kamata, Tomoyuki; Kato, Dai; Niwa, Osamu

    2017-06-06

    This paper reports an on-chip electrochemical assessment of the DNA methylation status in genomic DNA on a conductive nanocarbon film electrode realized with combined bisulfite restriction analysis (COBRA). The film electrode consists of sp 2 and sp 3 hybrid bonds and is fabricated with an unbalanced magnetron (UBM) sputtering method. First, we studied the effect of the sp 2 /sp 3 ratio of the UBM nanocarbon film electrode with p-aminophenol, which is a major electro-active product of the labeling enzyme from p-aminophenol phosphate. The signal current for p-aminophenol increases as the sp 2 content in the UBM nanocarbon film electrode increases because of the π-π interaction between aromatic p-aminophenol and the graphene-like sp 2 structure. Furthermore, the capacitative current at the UBM nanocarbon film electrode was successfully reduced by about 1 order of magnitude thanks to the angstrom-level surface flatness. Therefore, a high signal-to-noise ratio was achieved compared with that of conventional electrodes. Then, after performing an ELISA-like hybridization assay with a restriction enzyme, we undertook an electrochemical evaluation of the cytosine methylation status in DNA by measuring the oxidation current derived from p-aminophenol. When the target cytosine in the analyte sequence is methylated (unmethylated), the restriction enzyme of HpyCH4IV is able (unable) to cleave the sequence, that is, the detection probe cannot (can) hybridize. We succeeded in estimating the methylation ratio at a site-specific CpG site from the peak current of a cyclic voltammogram obtained from a PCR product solution ranging from 0.01 to 1 nM.

  1. Reliable clinical serum analysis with reusable electrochemical sensor: Toward point-of-care measurement of the antipsychotic medication clozapine.

    Science.gov (United States)

    Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F

    2017-09-15

    Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Ultrasensitive molecularly imprinted electrochemical sensor based on magnetism graphene oxide/β-cyclodextrin/Au nanoparticles composites for chrysoidine analysis

    International Nuclear Information System (INIS)

    Wang, Xiaojiao; Li, Xiangjun; Luo, Chuannan; Sun, Min; Li, Leilei; Duan, Huimin

    2014-01-01

    Highlights: • Synthesis and application of MGO/β-CD@AuNPs as a sensor for chrysoidine analysis. • The synthesized polymer had a laminar structure with high surface. • The propose sensor showed high selectivity and good sensitivity. - Abstract: A imprinted electrochemical sensor based on glassy carbon electrode (GCE) for ultrasensitive detection of chrysoidine was fabricated. A GCE was modified by magnetic graphene oxide/β-cyclodextrin/gold nanoparticles composites (MGO/β-CD@AuNPs). The sensing surface area and electronic transmission rate were increased, which was benefited from the distribution property of MGO/β-CD@AuNPs. The MGO/β-CD@AuNPs composite improved electrochemical response and sensitivity of the sensor. The molecularly imprinted electrochemical sensor was prepared by electropolymerization on modified electrode. Chrysoidine and pyrrole were used as template molecule and functional monomer, respectively. Under the optimization experimental conditions, the electrochemical sensor exhibited excellent analytical performance: the detection of chrysoidine ranged from 5.0 × 10 −8 mol/L to 5.0 × 10 −6 mol/L with the detection limit of 1.7 × 10 −8 mol/L. The sensor was applied to determine chrysoidine in spiked water samples and showed high selectivity, good sensitivity and acceptable reproducibility. The proposed method provides a promising platform for trace amount detection of other food additives

  3. Reactor noise analysis applications and systems in WWER-440 and WWER-1000 type PWRs

    International Nuclear Information System (INIS)

    Por, G.

    1998-01-01

    This paper presents an introduction on different types of well selected noise diagnostic methods with their occurrence in WWER reactors with an analysis of their impact on operational safety and aging which affects the installations safety as well. The main objective is to attract the attention of NPP management staff dealing with safety, safety culture, maintenance, operation and quality assurance proving that such methods can give benefit not only to economy but impact safety of nuclear installations

  4. Noise analysis and mimic experiments for loose part accident in the primary coolant loop of PWR

    International Nuclear Information System (INIS)

    Yang Xiuzhou; Cheng Tingxiang; Zhang Bin

    1994-01-01

    The basic principle of loose part monitoring is to detect and measure the structure transfer sound generated by impacting of metal loose part with accelerators and to identify and diagnose by the micro-processor. This paper introduces the theoretical base of loose part monitoring, the location and mass estimation of loose part, and three mimic experiment applying noise analysis techniques. It provides some useful preparations for the development of loose part monitoring system

  5. Application of the neutron noise analysis technique in nuclear power plants

    International Nuclear Information System (INIS)

    Lescano, Victor H.; Wentzeis, Luis M.

    1999-01-01

    Using the neutron noise analysis in nuclear power plants, and without producing any perturbation in the normal operation of the plant, information of the vibration state of the reactor internals and the behavior of the operating conditions of the reactor primary circuit can be obtained. In Argentina, the neutron noise analysis technique is applied in customary way in the nuclear power plants Atucha I and Embalse. A database was constructed and vibration frequencies corresponding to different reactor internals were characterized. Reactor internals with particular mechanical vibrations have been detected and localized. In the framing of a cooperation project between Argentina and Germany, we participated in the measurements, analysis and modelisation, using the neutron noise technique, in the Obrigheim and Gundremmingen nuclear power plants. In the nuclear power plant Obrigheim (PWR, 350 M We), correlations between the signals measured from self-power neutron detectors and accelerometers located inside the reactor core, were made. In the nuclear power plant Gundremmingen (BWR, 1200 M We) we participated in the study of a particular mechanical vibration detected in one of the instrumentation tube. (author)

  6. Analysis of annual exposure of private farmers to noise and whole body vibration

    Directory of Open Access Journals (Sweden)

    Leszek Solecki

    2012-06-01

    Full Text Available Based on a literature review for the period of 1982– 2011, an analysis was performed of studies by various researchers concerning the exposure of private farmers to noise and vibration of the whole body with particular consideration of the annual exposure to these factors. The main sources of noise occurring in agriculture are: agricultural tractors mounted with a set of farm machinery, self-propelled machines, machinery for the production of fodder and workshop equipment. The review of literature showed that the highest values of equivalent exposure to noise (EA, T or noise doses (d were noted during the summer-autumn season and in spring. Mean noise levels for the entire year (of over 90 dB-A, considerably exceeded permissible values.The primary sources of the whole body vibration are agricultural vehicles including agricultural tractors of various types and self-propelled agricultural vehicles. In these vehicles vibration transmitted from the seat to the whole body is of basic importance. The measurements of vibration acceleration indicated that mechanical vibration on seats was produced while performing following activities: hay tedding and raking, sowing of fertilizers, aggregation of soil, grass mowing and cultivation. All of them may create a considerable health risk. These work activities are performed at elevated working speeds of tractors, most often along with hardened or uneven surfaces. In relation to the standard values (A(840.8 m/s2, the mean daily vibration acceleration values remain below the permissible levels during all months of the year. However, considering the occurrence of mechanical shocks of high values (above the Maximum Acceptable Intensity on agricultural vehicles there is a high risk for the spine problems among operators of agricultural vehicles.

  7. Development of miniaturized disposable electrochemical systems intended for point of care blood analysis

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel

    to pH changes in a very reproducible way despite their very simple fabrication processes. Moreover, the developed voltammetric system presented the major advantage of limiting the potential issues stemming from the reference half-cell. Indeed, since the measurement principle was based on evaluating...... that significant differences in terms of electrochemical, mechanical and electrical properties exist between these products. The effect of electrochemical and thermal treatments of the screen-printed materials was also investigated. This study resulted in the selection of an optimal electrochemical system used...... species. Moreover, to my knowledge, the use of SP for the development of this type of voltammetric systems has surprisingly only been recently investigated by D. K. Kampouris et al. [1] despite its undeniable advantages. Electrochemical measurements highlighted the promising performances...

  8. Analysis of power tiller noise using diesel-biodiesel fuel blends

    Directory of Open Access Journals (Sweden)

    N Keramat Siavash

    2015-09-01

    , capacitor microphone with a unidirectional pattern whose size, sensitivity and frequency range are 1/2", 50 mV Pa-1 and 10 Hz to 20 kHz with a flat extrusion, respectively. Choosing the combination of fuel was carried out according to experiments that have been done before determining engine operation parameters. Results and Discussion: Fuel type has a direct effect on the quality of the IC engine's combustion phenomenon. One of the most important quality parameters that can be fluctuated by fuel type is engine noise. The fuel type has a direct effect on internal fuel ignition engines and affects the quality of fuel ignition. One of the effects of ignition quality is the sound of the engine that is very important in terms of both the health and evaluation of engine performance. Two-wheel tractors are of the most important tools used in agriculture. In addition to agricultural work, they have applications in rural areas as power generators. No research has been carried out so far in Iran on the sound of two-wheel tractors fuelled with diesel and biodiesel fuels. Therefore, the sound of the ignition of biodiesel and diesel mixtures in four stroke, single cylinder, two wheel diesel tractors manufactured by Ashtad Company was studied. The purpose of this study is to analyze the noise parameters of a diesel engine using B0, B5, B10, B15, B20, B25 and B30 biodiesel–diesel blends. Biodiesel was produced from waste oil and blended with net diesel fuel to evaluate the Power tiller's engine noise parameters. This study was carried out at a stationary position and at three positions such as driver's left ear position (DLEP, 1.5 meter (1.5 MAFE and 7.5 meters (7.5 MAFE away from the exhaust at 6 engine speeds (1200, 1400, 1600, 1800, 2000 & 2200 rpm. Statistical analysis and frequency analysis were used to analyze sound of the engine. The results showed that the sound pressure levels of the engine for B10 fuel have the least amount of noise level of the sound pressure. However, this

  9. On the role of magnetic field intensity for better micro-structural characterization during Barkhausen Noise analysis

    Science.gov (United States)

    Yusufzai, Mohd Zaheer Khan; Vashista, M.

    2018-04-01

    Barkhausen Noise analysis is a popular and preferred technique for micro-structural characterization. The root mean square value and peak value of Barkhausen Noise burst are important parameters to assess the micro-hardness and residual stress. Barkhausen Noise burst can be enveloped using a curve known as Barkhausen Noise profile. Peak position of profile changes with change in micro-structure. In the present work, raw signal of Barkhausen Noise burst was obtained from Ni based sample at various magnetic field intensity to observe the effect of variation in field intensity on Barkhausen Noise burst. Raw signal was opened using MATLAB to further process for microstructure analysis. Barkhausen Noise analysis parameters such as magnetizing frequency, number of burst, high pass and low pass filter frequency were kept constant and magnetizing field was varied in wide range between 200 Oe to 1200 Oe. The processed profiles of Barkhausen Noise burst obtained at various magnetizing field intensity clearly reveals requirement of optimum magnetic field strength for better characterization of micro-structure.

  10. Enhanced electrocatalytic oxidation of isoniazid at electrochemically modified rhodium electrode for biological and pharmaceutical analysis.

    Science.gov (United States)

    Cheemalapati, Srikanth; Chen, Shen-Ming; Ali, M Ajmal; Al-Hemaid, Fahad M A

    2014-09-01

    A simple and sensitive electrochemical method has been proposed for the determination of isoniazid (INZ). For the first time, rhodium (Rh) modified glassy carbon electrode (GCE) has been employed for the determination of INZ by linear sweep voltammetry technique (LSV). Compared with the unmodified electrode, the proposed Rh modified electrode provides strong electrocatalytic activity toward INZ with significant enhancement in the anodic peak current. Scanning electron microscopy (SEM) and field emission scanning electron microscopy (FESEM) results reveal the morphology of Rh particles. With the advantages of wide linearity (70-1300μM), good sensitivity (0.139μAμM(-1)cm(-2)) and low detection limit (13μM), this proposed sensor holds great potential for the determination of INZ in real samples. The practicality of the proposed electrode for the detection of INZ in human urine and blood plasma samples has been successfully demonstrated using LSV technique. Through the determination of INZ in commercially available pharmaceutical tablets, the practical applicability of the proposed method has been validated. The recovery results are found to be in good agreement with the labeled amounts of INZ in tablets, thus showing its great potential for use in clinical and pharmaceutical analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Electrochemical Impedance Analysis of a PEDOT:PSS-Based Textile Energy Storage Device

    Directory of Open Access Journals (Sweden)

    Ida Nuramdhani

    2017-12-01

    Full Text Available A textile-based energy storage device with electroactive PEDOT:PSS (poly(3,4-ethylenedioxythiophene/poly(4-styrenesulfonate polymer functioning as a solid-state polyelectrolyte has been developed. The device was fabricated on textile fabric with two plies of stainless-steel electroconductive yarn as the electrodes. In this study, cyclic voltammetry and electrochemical impedance analysis were used to investigate ionic and electronic activities in the bulk of PEDOT:PSS and at its interfaces with stainless steel yarn electrodes. The complex behavior of ionic and electronic origins was observed in the interfacial region between the conductive polymer and the electrodes. The migration and diffusion of the ions involved were confirmed by the presence of the Warburg element with a phase shift of 45° (n = 0.5. Two different equivalent circuit models were found by simulating the model with the experimental results: (QR(QR(QR for uncharged and (QR(QR(Q(RW for charged samples. The analyses also showed that the further the distance between electrodes, the lower the capacitance of the cell. The distribution of polymer on the cell surface also played important role to change the capacitance of the device. The results of this work may lead to a better understanding of the mechanism and how to improve the performance of the device.

  12. Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soyoung [Department of Radiation Oncology, University Hospitals Case and Medical Center, Cleveland, Ohio 44106 (United States); Yan, Guanghua; Bassett, Philip; Samant, Sanjiv, E-mail: samant@ufl.edu [Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida 32608 (United States); Gopal, Arun [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States)

    2016-09-15

    Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two

  13. Method for analyzing electromagnetic-force-induced vibration and noise analysis; Denjiryoku reiki ni yoru dendoki no shindo hoshaon kaisekiho

    Energy Technology Data Exchange (ETDEWEB)

    Shiohata, K.; Nemoto, K.; Nagawa, Y.; Sakamoto, S.; Kobayashi, T.; Ito, M.; Koharagi, H. [Hitachi, Ltd, Tokyo (Japan)

    1998-11-01

    In this analysis method, electromagnetic force calculated by 2-dimensional analysis is transformed into external force for 3-dimensional structural-vibration analysis. And a modeling procedure for a vibrating structure is developed. Further, a space-modal-resonance criteria which relates electromagnetic force to structural-vibration or noise is introduced. In the structural-vibration analysis, the finite element method is used; and in the noise analysis, the boundary element method is used. Finally, vibration and noise of an induction motor are calculated using this criteria. Consequently, high-accuracy modeling is achieved and noise the calculated by the simulation almost coincides with that obtained by experiments. And it is clarified that the-space-modal resonance criteria is effective in numerical simulation. 11 refs., 9 figs., 3 tabs.

  14. Simulation and stability analysis of supersonic impinging jet noise with microjet control

    Science.gov (United States)

    Hildebrand, Nathaniel; Nichols, Joseph W.

    2014-11-01

    A model for an ideally expanded 1.5 Mach turbulent jet impinging on a flat plate using unstructured high-fidelity large eddy simulations (LES) and hydrodynamic stability analysis is presented. Note the LES configuration conforms exactly to experiments performed at the STOVL supersonic jet facility of the Florida Center for Advanced Aero-Propulsion allowing validation against experimental measurements. The LES are repeated for different nozzle-wall separation distances as well as with and without the addition of sixteen microjets positioned uniformly around the nozzle lip. For some nozzle-wall distances, but not all, the microjets result in substantial noise reduction. Observations of substantial noise reduction are associated with a relative absence of large-scale coherent vortices in the jet shear layer. To better understand and predict the effectiveness of microjet noise control, the application of global stability analysis about LES mean fields is used to extract axisymmetric and helical instability modes connected to the complex interplay between the coherent vortices, shocks, and acoustic feedback. We gratefully acknowledge computational resources provided by the Argonne Leadership Computing Facility.

  15. Antigen-antibody biorecognition events as discriminated by noise analysis of force spectroscopy curves.

    Science.gov (United States)

    Bizzarri, Anna Rita; Cannistraro, Salvatore

    2014-08-22

    Atomic force spectroscopy is able to extract kinetic and thermodynamic parameters of biomolecular complexes provided that the registered unbinding force curves could be reliably attributed to the rupture of the specific complex interactions. To this aim, a commonly used strategy is based on the analysis of the stretching features of polymeric linkers which are suitably introduced in the biomolecule-substrate immobilization procedure. Alternatively, we present a method to select force curves corresponding to specific biorecognition events, which relies on a careful analysis of the force fluctuations of the biomolecule-functionalized cantilever tip during its approach to the partner molecules immobilized on a substrate. In the low frequency region, a characteristic 1/f (α) noise with α equal to one (flickering noise) is found to replace white noise in the cantilever fluctuation power spectrum when, and only when, a specific biorecognition process between the partners occurs. The method, which has been validated on a well-characterized antigen-antibody complex, represents a fast, yet reliable alternative to the use of linkers which may involve additional surface chemistry and reproducibility concerns.

  16. A trade-off analysis design tool. Aircraft interior noise-motion/passenger satisfaction model

    Science.gov (United States)

    Jacobson, I. D.

    1977-01-01

    A design tool was developed to enhance aircraft passenger satisfaction. The effect of aircraft interior motion and noise on passenger comfort and satisfaction was modelled. Effects of individual aircraft noise sources were accounted for, and the impact of noise on passenger activities and noise levels to safeguard passenger hearing were investigated. The motion noise effect models provide a means for tradeoff analyses between noise and motion variables, and also provide a framework for optimizing noise reduction among noise sources. Data for the models were collected onboard commercial aircraft flights and specially scheduled tests.

  17. Design and analysis of a BLPC vocoder-based adaptive feedback cancellation with probe noise

    DEFF Research Database (Denmark)

    Anand, Ankita; Kar, Asutosh; Swamy, M.N.S.

    2017-01-01

    a BLPC vocoderbased adaptive feedback canceller with probe noise with an objective of reducing the low-frequency bias in digital hearing-aids. A step-wise mathematical analysis of the proposed feedback canceller is presented employing the recursive least square and normalized least mean square adaptive......The band-limited linear predictive coding (BLPC) vocoder-based adaptive feedback cancellation (AFC) removes the high-frequency bias, while the low frequency bias persists between the desired input signal and the loudspeaker signal in the estimate of the feedback path. In this paper, we present...... algorithms. It is observed that the optimal solution of the feedback path is unbiased for an unshaped probe noise, but is biased for a shaped probe signal; the bias term does not consist of correlation between the desired input and the loudspeaker output. The identifiability conditions are analysed...

  18. Comparison of JADE and canonical correlation analysis for ECG de-noising.

    Science.gov (United States)

    Kuzilek, Jakub; Kremen, Vaclav; Lhotska, Lenka

    2014-01-01

    This paper explores differences between two methods for blind source separation within frame of ECG de-noising. First method is joint approximate diagonalization of eigenmatrices, which is based on estimation of fourth order cross-cummulant tensor and its diagonalization. Second one is the statistical method known as canonical correlation analysis, which is based on estimation of correlation matrices between two multidimensional variables. Both methods were used within method, which combines the blind source separation algorithm with decision tree. The evaluation was made on large database of 382 long-term ECG signals and the results were examined. Biggest difference was found in results of 50 Hz power line interference where the CCA algorithm completely failed. Thus main power of CCA lies in estimation of unstructured noise within ECG. JADE algorithm has larger computational complexity thus the CCA perfomed faster when estimating the components.

  19. Signal-to-noise ratio application to seismic marker analysis and fracture detection

    Science.gov (United States)

    Xu, Hui-Qun; Gui, Zhi-Xian

    2014-03-01

    Seismic data with high signal-to-noise ratios (SNRs) are useful in reservoir exploration. To obtain high SNR seismic data, significant effort is required to achieve noise attenuation in seismic data processing, which is costly in materials, and human and financial resources. We introduce a method for improving the SNR of seismic data. The SNR is calculated by using the frequency domain method. Furthermore, we optimize and discuss the critical parameters and calculation procedure. We applied the proposed method on real data and found that the SNR is high in the seismic marker and low in the fracture zone. Consequently, this can be used to extract detailed information about fracture zones that are inferred by structural analysis but not observed in conventional seismic data.

  20. Source-driven noise analysis measurements with neptunium metal reflected by high enriched uranium

    International Nuclear Information System (INIS)

    Valentine, Timothy E.; Mattingly, John K.

    2003-01-01

    Subcritical noise analysis measurements have been performed with neptunium ( 237 Np) sphere reflected by highly enriched uranium. These measurements were performed at the Los Alamos Critical Experiment Facility in December 2002 to provide an estimate of the subcriticality of 237 Np reflected by various amounts of high-enriched uranium. This paper provides a description of the measurements and presents some preliminary results of the analysis of the measurements. The measured and calculated spectral ratios differ by 15% whereas the 'interpreted' and calculated k eff values differ by approximately 1%. (author)

  1. Validation of the dynamics of SDS and RRS flux, flow, pressure and temperature signals using noise analysis technique

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Tulett, M.V.

    1995-01-01

    In 1992, a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro's CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. Critical plant components, instrumentation and processes are monitored on a regular basis, and their dynamic characteristics are verified on-power. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes, reactivity devices and fuel channels induced by moderator/coolant flow, (6) estimating the dynamics and response time of RTD temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (1 0) detecting coolant boiling in fully instrumented fuel channels, (1 1) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the

  2. Assessment and analysis of noise levels in and around Ib river coalfield, Orissa, India.

    Science.gov (United States)

    Mohapatra, Haraprasad; Goswami, Shreerup

    2012-05-01

    Heavy earth moving machineries, different capacities of dumpers and loaders, blasting and drilling make the mining environment noisy. A study was carried out to assess the noise level in different opencast projects in and around Belpahar and Brajarajnagar areas of Ib river coalfield. Noise assessment was carried out in various residential, commercial and industrial places. The noise levels, especially L(eq) values of different wheel loaders, dumpers, shovel and crusher units were also assessed and were more than permissible limit (90dB) in some of their operating conditions. Sound ressure level measurements while drilling into coal and overburden at Lakhanpur opencast project yielded noise levels (L(eq)) of 81.33 to 96.2 dB. Thus, these L(eq) values of drilling machines in most of the operating conditions were above permissible limit. The average noise intensities (6 a.m.-10 p.m.: 51.6-60.875dB and 10 p.m.-6 a.m.: 42.6-49.8dB) and L(eq) values (6 a.m.-10 p.m.: 50.9-67.0dB and 10 p.m.-6 a.m.: 40.8-53.3dB) during both day and night time of the residential areas around the Ib river coalfield were in close proximity or beyond the permissible limit. The L(eq) values at some of the commercial and industrial places were beyond (6 a.m.-10 p.m.: 61.6-88.3 dB and 10 p.m.-6 a.m.: 55.4-64.8dB) permissible limit. However, in most of the cases, the L(max) noise values were more (6 a.m.-10 p.m.: 68.5-91.4 dB and 10 p.m.-6 a.m.: 69.3-76.4dB) than the permissible limit. Analysis of variance was also computed for heavy earth moving machineries in different operating conditions and also for different residential, commercial and industrial places to infer the level of significance. The difference of noise intensity produced by different wheel loaders at Lakhanpur and Lilari opencast projects, drilling machines at Lakhanpur opencast project, 50 tons capacity dumpers at various conditions of Ib river coalfield within the same operating condition was significant at both 5% and 1% levels

  3. Measurement and Analysis of the Noise Radiated by Low Mach Number Centrifugal Blowers.

    Science.gov (United States)

    Yeager, David Marvin

    An investigation was performed of the broad band, aerodynamically generated noise in low tip-speed Mach number, centrifugal air moving devices. An interdisciplinary experimental approach was taken which involved investigation of the aerodynamic and acoustic fields, and their mutual relationship. The noise generation process was studied using two experimental vehicles: (1) a scale model of a homologous family of centrifugal blowers typical of those used to cool computer and business equipment, and (2) a single blade from a centrifugal blower impeller placed in a known, controllable flow field. The radiation characteristics of the model blower were investigated by measuring the acoustic intensity distribution near the blower inlet and comparing it with the intensity near the inlet to an axial flow fan. Results showed that the centrifugal blower is a distributed, random noise source, unlike an axial fan which exhibited the effects of a coherent, interacting source distribution. Aerodynamic studies of the flow field in the inlet and at the discharge to the rotating impeller were used to assess the mean flow distribution through the impeller blade channels and to identify regions of excessive turbulence near the rotating blade row. Both circumferential and spanwise mean flow nonuniformities were identified along with a region of increased turbulence just downstream of the scroll cutoff. The fluid incidence angle, normally taken as an indicator of blower performance, was estimated from mean flow data as deviating considerably from an ideal impeller design. An investigation of the noise radiated from the single, isolated airfoil was performed using modern correlation and spectral analysis techniques. Radiation from the single blade in flow was characterized using newly developed expressions for the correlation area and the dipole source strength per unit area, and from the relationship between the blade surface pressure and the incident turbulent flow field. Results

  4. Nanostructured surfaces for analysis of anticancer drug and cell diagnosis based on electrochemical and SERS tools

    Science.gov (United States)

    El-Said, Waleed A.; Yoon, Jinho; Choi, Jeong-Woo

    2018-04-01

    Discovering new anticancer drugs and screening their efficacy requires a huge amount of resources and time-consuming processes. The development of fast, sensitive, and nondestructive methods for the in vitro and in vivo detection of anticancer drugs' effects and action mechanisms have been done to reduce the time and resources required to discover new anticancer drugs. For the in vitro and in vivo detection of the efficiency, distribution, and action mechanism of anticancer drugs, the applications of electrochemical techniques such as electrochemical cell chips and optical techniques such as surface-enhanced Raman spectroscopy (SERS) have been developed based on the nanostructured surface. Research focused on electrochemical cell chips and the SERS technique have been reviewed here; electrochemical cell chips based on nanostructured surfaces have been developed for the in vitro detection of cell viability and the evaluation of the effects of anticancer drugs, which showed the high capability to evaluate the cytotoxic effects of several chemicals at low concentrations. SERS technique based on the nanostructured surface have been used as label-free, simple, and nondestructive techniques for the in vitro and in vivo monitoring of the distribution, mechanism, and metabolism of different anticancer drugs at the cellular level. The use of electrochemical cell chips and the SERS technique based on the nanostructured surface should be good tools to detect the effects and action mechanisms of anticancer drugs.

  5. A CAMAC based real-time noise analysis system for nuclear reactors

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1987-01-01

    A CAMAC based real-time noise analysis system was designed for the TRIGA MARK II nuclear reactor at the Institute for Nuclear Energy, Istanbul. The input analog signals obtained from the radiation detectors are introduced to the system through CAMAC interface. The signals coverted into digital form are processed by a PDP-11 computer. The fast data processing based on auto/cross power spectral density computations is carried out by means of assembly written FFT algorithms in real-time and the spectra obtained are displayed on a CAMAC driven display system as an additional monitoring device. The system has the advantage of being software programmable and controlled by a CAMAC system so that it is operated under porgram control for reactor surveillance, anomaly detection and diagnosis. The system can also be used for the identification of nonstationary operational characteristics of the reactor in long term by comparing the noise power spectra with the corresponding reference noise patterns prepared in advance. (orig.)

  6. Electrochemical approach for acute myocardial infarction diagnosis based on direct antibodies-free analysis of human blood plasma.

    Science.gov (United States)

    Suprun, Elena V; Saveliev, Anatoly A; Evtugyn, Gennady A; Lisitsa, Alexander V; Bulko, Tatiana V; Shumyantseva, Victoria V; Archakov, Alexander I

    2012-03-15

    A novel direct antibodies-free electrochemical approach for acute myocardial infarction (AMI) diagnosis has been developed. For this purpose, a combination of the electrochemical assay of plasma samples with chemometrics was proposed. Screen printed carbon electrodes modified with didodecyldimethylammonium bromide were used for plasma charactrerization by cyclic (CV) and square wave voltammetry and square wave (SWV) voltammetry. It was shown that the cathodic peak in voltammograms at about -250 mV vs. Ag/AgCl can be associated with AMI. In parallel tests, cardiac myoglobin and troponin I, the AMI biomarkers, were determined in each sample by RAMP immunoassay. The applicability of the electrochemical testing for AMI diagnostics was confirmed by statistical methods: generalized linear model (GLM), linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA), artificial neural net (multi-layer perception, MLP), and support vector machine (SVM), all of which were created to obtain the "True-False" distribution prediction where "True" and "False" are, respectively, positive and negative decision about an illness event. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Measurement of two-phase flow variables in a BWR by analysis of in-core neutron detector noise signals

    International Nuclear Information System (INIS)

    Stekelenburg, A.J.C.; Hagen, T.H.J.J. van der

    1996-01-01

    In this paper, the state of the art of the measurement of two-phase flow variables in a boiling water reactor (BWR) by analysis of in-core neutron detector noise signals is given. It is concluded that the neutronic processes involved in neutron noise are quite well understood, but that little is known about the density fluctuations in two-phase flow which are the main cause of the neutron noise. For this reason, the neutron noise measurements, like the well known two-detector velocity measurements, are still difficult to interpret. By analyzing neutron noise measurements in a natural circulation cooled BWR, it is illustrated that, once a theory on the density fluctuations is developed, two-phase flow can be monitored with a single in-core detector. (author). 70 refs, 4 figs

  8. Signal discrimination of ULF electromagnetic data with using singular spectrum analysis – an attempt to detect train noise

    Directory of Open Access Journals (Sweden)

    S. Saito

    2011-07-01

    Full Text Available Electromagnetic phenomena associated with crustal activities have been reported in a wide frequency range (DC-HF. In particular, ULF electromagnetic phenomena are the most promising among them because of the deeper skin depth. However, ULF geoelctromagnetic data are a superposition of signals of different origins. They originated from interactions between the geomagnetic field and the solar wind, leak current by a DC-driven train (train noise, precipitation, and so on. In general, the intensity of electromagnetic signals associated with crustal activity is smaller than the above variations. Therefore, in order to detect a smaller signal, signal discrimination such as noise reduction or identification of noises is very important. In this paper, the singular spectrum analysis (SSA has been performed to detect the DC-driven train noise in geoelectric potential difference data. The aim of this paper is to develop an effective algorithm for the DC-driven train noise detection.

  9. NEIGHBOURHOOD ANALYSIS OF THE IMPACT CAUSED BY THE NOISE IN A WEIGHT TRAINING ACADEMY OF A HAIR SALON

    Directory of Open Access Journals (Sweden)

    Diani Fernanda Silva

    2011-08-01

    Full Text Available The analysis of neighborhood impact associated to noise is very important to the living and working environments independently of our activity. The legislative Brazilian norm NBR 10151 imposes limits of noise produced by business establishments. The maximum values of acoustic comfort on the surrounding community are 60 dB at daytime and 55 dB at nighttime. Environments as gym, perform music at high intensity as an incentive to practice physical exercises, however, excessive continuous noise produced by sound equipment may cause annoyance for adjacent environments, as a hairdresser analyzed in this study. Among the complaints of the professionals are digestive disorders, headaches, increase disturbances of concentration, dizziness, sleeping disturbs, anxiety, fatigue and stress. Inevitably, noise is a result of almost all our activities. We could improve our quality of life by avoiding the hazardous noise.

  10. Variation and stability in Dutch noise policy: an analysis of dominant advocacy coalitions

    NARCIS (Netherlands)

    Weber, M.; Driessen, P.P.J.; Schueler, B.J.; Runhaar, H.A.C.

    2013-01-01

    Noise exposure has harmful effects on human health. Despite policy on the prevention and reduction of noise, the environmental burden is increasing, specifically due to road traffic noise. Noise policy in the Netherlands is organised in a rather complex way, with different legal frameworks for the

  11. Quantitative analysis of the anti-noise performance of an m-sequence in an electromagnetic method

    Science.gov (United States)

    Yuan, Zhe; Zhang, Yiming; Zheng, Qijia

    2018-02-01

    An electromagnetic method with a transmitted waveform coded by an m-sequence achieved better anti-noise performance compared to the conventional manner with a square-wave. The anti-noise performance of the m-sequence varied with multiple coding parameters; hence, a quantitative analysis of the anti-noise performance for m-sequences with different coding parameters was required to optimize them. This paper proposes the concept of an identification system, with the identified Earth impulse response obtained by measuring the system output with the input of the voltage response. A quantitative analysis of the anti-noise performance of the m-sequence was achieved by analyzing the amplitude-frequency response of the corresponding identification system. The effects of the coding parameters on the anti-noise performance are summarized by numerical simulation, and their optimization is further discussed in our conclusions; the validity of the conclusions is further verified by field experiment. The quantitative analysis method proposed in this paper provides a new insight into the anti-noise mechanism of the m-sequence, and could be used to evaluate the anti-noise performance of artificial sources in other time-domain exploration methods, such as the seismic method.

  12. Estimation of background noise level on seismic station using statistical analysis for improved analysis accuracy

    Science.gov (United States)

    Han, S. M.; Hahm, I.

    2015-12-01

    We evaluated the background noise level of seismic stations in order to collect the observation data of high quality and produce accurate seismic information. Determining of the background noise level was used PSD (Power Spectral Density) method by McNamara and Buland (2004) in this study. This method that used long-term data is influenced by not only innate electronic noise of sensor and a pulse wave resulting from stabilizing but also missing data and controlled by the specified frequency which is affected by the irregular signals without site characteristics. It is hard and inefficient to implement process that filters out the abnormal signal within the automated system. To solve these problems, we devised a method for extracting the data which normally distributed with 90 to 99% confidence intervals at each period. The availability of the method was verified using 62-seismic stations with broadband and short-period sensors operated by the KMA (Korea Meteorological Administration). Evaluation standards were NHNM (New High Noise Model) and NLNM (New Low Noise Model) published by the USGS (United States Geological Survey). It was designed based on the western United States. However, Korean Peninsula surrounded by the ocean on three sides has a complicated geological structure and a high population density. So, we re-designed an appropriate model in Korean peninsula by statistically combined result. The important feature is that secondary-microseism peak appeared at a higher frequency band. Acknowledgements: This research was carried out as a part of "Research for the Meteorological and Earthquake Observation Technology and Its Application" supported by the 2015 National Institute of Meteorological Research (NIMR) in the Korea Meteorological Administration.

  13. Noise Sensitivities in Dogs: An Exploration of Signs in Dogs with and without Musculoskeletal Pain Using Qualitative Content Analysis.

    Science.gov (United States)

    Lopes Fagundes, Ana Luisa; Hewison, Lynn; McPeake, Kevin J; Zulch, Helen; Mills, Daniel Simon

    2018-01-01

    Noise sensitivity is a common behaviour problem in dogs. In humans, there is a well-established relationship between painful conditions and the development of fear-related avoidance responses. Whilst it is likely that a relationship exists between noise sensitivity and pain in dogs, this does not appear to have been investigated. The aim of this study was to explore the signs of noise sensitivity in dogs with and without musculoskeletal pain by comparing case histories using qualitative content analysis. Data were extracted from the clinical records of 20 cases of dogs presenting with noise sensitivity seen by clinical animal behaviourists at the University of Lincoln, composed of 2 groups-10 "clinical cases" with pain and 10 "control cases" without pain. Loud noises as a trigger of noise sensitivity were a common theme in both groups but ubiquitous among "clinical cases." In "clinical cases" (i.e., those where pain was identified), the age of onset of the noise sensitivity was on average nearly 4 years later than "control cases." In addition, strong themes emerged relating to widespread generalisation to associated environments and avoidance of other dogs in the "clinical cases," which did not appear in the "control cases." "Clinical cases" responded well to treatment once the involvement of pain had been identified. Veterinarians and behaviourists should carefully assess dogs with noise sensitivities for pain-related problems especially if presenting with these characteristics.

  14. Relation between nonlinear or 'not-linear' characteristics in nuclear kinetics and noise analysis of neutron flux

    International Nuclear Information System (INIS)

    Kataoka, H.

    1975-01-01

    The 'not-linear' or '2nd-class-nonlinear' characteristics in nuclear reactor kinetics with the feedback effect in the high-power operation and induce the increase in the amplitude of the neutron flux noise, specially in the very low frequency region. The fundamental behaviour of 'not-linear' characteristics and its effect for the reactor noise was investigated. Application of the reactor noise analysis technique to power reactors has not been successful because of unknown large disagreement between the result of the conventional theoretical analysis and the experimental facts. When the cause of this discrepancy is clear, reactor noise analysis techniques can be effectively applied to instrumentation, control, monitoring and diagnosis of power reactors. (author)

  15. Fast and sensitive detection of foodborne pathogen using electrochemical impedance analysis, urease catalysis and microfluidics.

    Science.gov (United States)

    Chen, Qi; Wang, Dan; Cai, Gaozhe; Xiong, Yonghua; Li, Yuntao; Wang, Maohua; Huo, Huiling; Lin, Jianhan

    2016-12-15

    Early screening of pathogenic bacteria is a key to prevent and control of foodborne diseases. In this study, we developed a fast and sensitive bacteria detection method integrating electrochemical impedance analysis, urease catalysis with microfluidics and using Listeria as model. The Listeria cells, the anti-Listeria monoclonal antibodies modified magnetic nanoparticles (MNPs), and the anti-Listeria polyclonal antibodies and urease modified gold nanoparticles (AuNPs) were incubated in a fluidic separation chip with active mixing to form the MNP-Listeria-AuNP-urease sandwich complexes. The complexes were captured in the separation chip by applying a high gradient magnetic field, and the urea was injected to resuspend the complexes and hydrolyzed under the catalysis of the urease on the complexes into ammonium ions and carbonate ions, which were transported into a microfluidic detection chip with an interdigitated microelectrode for impedance measurement to determine the amount of the Listeria cells. The capture efficiency of the Listeria cells in the separation chip was ∼93% with a shorter time of 30min due to the faster immuno-reaction using the active magnetic mixing. The changes on both impedance magnitude and phase angle were demonstrated to be able to detect the Listeria cells as low as 1.6×10(2)CFU/mL. The detection time was reduced from original ∼2h to current ∼1h. The recoveries of the spiked lettuce samples ranged from 82.1% to 89.6%, indicating the applicability of this proposed biosensor. This microfluidic impedance biosensor has shown the potential for online, automatic and sensitive bacteria separation and detection. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Analysis of Off Gas From Disintegration Process of Graphite Matrix by Electrochemical Method

    International Nuclear Information System (INIS)

    Tian Lifang; Wen Mingfen; Chen Jing

    2010-01-01

    Using electrochemical method with salt solutions as electrolyte, some gaseous substances (off gas) would be generated during the disintegration of graphite from high-temperature gas-cooled reactor fuel elements. The off gas is determined to be composed of H 2 , O 2 , N 2 , CO 2 and NO x by gas chromatography. Only about 1.5% graphite matrix is oxidized to CO 2 . Compared to the direct burning-graphite method, less off gas,especially CO 2 , is generated in the disintegration process of graphite by electrochemical method and the treatment of off gas becomes much easier. (authors)

  17. Background noise analysis in urban airport surroundings of Brazilian cities, Congonhas Airport, São Paulo.

    Science.gov (United States)

    Scatolini, Fabio; Alves, Cláudio Jorge Pinto

    2016-12-22

    To perform a quantitative analysis of the background noise at Congonhas Airport surroundings based on large sampling and measurements with no interruption. Measuring sites were chosen from 62 and 72 DNL (day-night-level) noise contours, in urban sites compatible with residential use. Fifteen sites were monitored for at least 168 hours without interruption or seven consecutive days. Data compilation was based on cross-reference between noise measurements and air traffic control records, and results were validated by airport meteorological reports. Preliminary diagnoses were established using the standard NBR-13368. Background noise values were calculated based on the Sound Exposure Level (SEL). Statistic parameters were calculated in one-hour intervals. Only four of the fifteen sites assessed presented aircraft operations as a clear cause for the noise annoyance. Even so, it is possible to detect background noise levels above regulation limits during periods of low airport activity or when it closes at night. All the sites monitored showed background noise levels above regulation limits between 7:00 and 21:00. In the intervals between 6:00-6:59 and 21:00-22:59 the noise data, when analyzed with the current airport operational characteristics, still allow the development of additional mitigating measures. Avaliar quantitativamente o ruído de fundo no entorno do aeroporto de Congonhas, com base em ampla amostragem e medições sem interrupção. Locais de medição escolhidos a partir de curvas de ruído de 62 e 72 LDN (day-night level), em equipamentos urbanos de uso compatível com o residencial. Quinze locais foram avaliados por mais de 168 horas consecutivas cada um (sete dias). A compilação baseou-se em cruzamentos de dados do controle de tráfego aéreo e os resultados foram validados por meio de relatórios meteorológicos do aeroporto. Diagnósticos preliminares foram estabelecidos utilizando a NBR-13368. O ruído de fundo foi calculado com base no Sound

  18. Investigation of power oscillation mechanisms based on noise analysis at Forsmark-1 BWR

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1996-01-01

    Noise analysis has been performed for stability test data collected during reactor start-up in January 1989 at the boiling water reactor (BWR) Forsmark unit 1. A unique instrumentation to measure local coolant flow in this reactor allowed investigation of dynamic interactions between neutron flux and coolant flow noise signals at different radial positions in the core. The causal relationship for these signals was evaluated based on a method called signal transmission path (STP) analysis with the aim of identifying the principal mechanism of power oscillations in this reactor. The results of the present study indicated that large amplitude power oscillations were induced by two instability mechanisms concurrent in the core. The first is the global void reactivity feedback effect which played the most significant role to power oscillations at a resonant frequency of about 0.53 Hz. The second is the thermal-hydraulics coupling with neutron kinetics, inducing resonant oscillations at about 0.45 Hz. The latter was found to be active only in a certain core region. A peculiar phenomenon of amplitude modulations observed in some local power range monitor (LPRM) signals was also examined. It was interpreted to occur as the consequence of these two resonant power oscillations, the frequencies of which lie close to each other. The noise analysis technique applied in the present study is expected to be useful to get a deeper understanding of the power oscillation mechanism which is active in the reactor under evaluation. The technique may be applicable to BWRs with instruments to measure local channel flow together with in-core neutron detectors. (Author)

  19. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    Directory of Open Access Journals (Sweden)

    Anastasios Economou

    2018-03-01

    Full Text Available This work reviews the field of screen-printed electrodes (SPEs modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of “green” metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  20. Finite element analysis for friction noise of simplified hip joint and its experimental validation

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jae Hyun; Choi, Hoil; Kang, Jae Young [Div. of Mechanical and Automotive Engineering, College of Engineering, Kongju National University, Cheonan (Korea, Republic of)

    2016-08-15

    In a hip joint system, squeak noise often occurs due to friction between the ball and hemispherical cup. To analyze the dynamic instability induced by friction in the hip joint system, the dynamic ball joint model was constructed by using the finite element method. The results from stability analysis revealed that the mode-coupling type instability occurred for one bending mode and its adjacent composite mode with the axial and transverse displacements with the increase of friction coefficient. The vitro squeak test and vibration modal tests confirmed that squeak arose near the frequency of the mode pair.

  1. Sound the alarm: A meta-analysis on the effect of aquatic noise on fish behavior and physiology.

    Science.gov (United States)

    Cox, Kieran; Brennan, Lawrence P; Gerwing, Travis G; Dudas, Sarah E; Juanes, Francis

    2018-07-01

    The aquatic environment is increasingly bombarded by a wide variety of noise pollutants whose range and intensity are increasing with each passing decade. Yet, little is known about how aquatic noise affects marine communities. To determine the implications that changes to the soundscape may have on fishes, a meta-analysis was conducted focusing on the ramifications of noise on fish behavior and physiology. Our meta-analysis identified 42 studies that produced 2,354 data points, which in turn indicated that anthropogenic noise negatively affects fish behavior and physiology. The most predominate responses occurred within foraging ability, predation risk, and reproductive success. Additionally, anthropogenic noise was shown to increase the hearing thresholds and cortisol levels of numerous species while tones, biological, and environmental noise were most likely to affect complex movements and swimming abilities. These findings suggest that the majority of fish species are sensitive to changes in the aquatic soundscape, and depending on the noise source, species responses may have extreme and negative fitness consequences. As such, this global synthesis should serve as a warning of the potentially dire consequences facing marine ecosystems if alterations to aquatic soundscapes continue on their current trajectory. © 2018 John Wiley & Sons Ltd.

  2. Analysis and development of deterministic and stochastic neutron noise computing techniques with applications to thermal and fast reactors

    International Nuclear Information System (INIS)

    Rouchon, Amelie

    2016-01-01

    Neutron noise analysis addresses the description of small time-dependent flux fluctuations induced by small global or local perturbations of the macroscopic cross-sections. These fluctuations may occur in nuclear reactors due to density fluctuations of the coolant, to vibrations of fuel elements, control rods, or any other structures in the core. In power reactors, ex-core and in-core detectors can be used to monitor neutron noise with the aim of detecting possible anomalies and taking the necessary measures for continuous safe power production. The objective of this thesis is to develop techniques for neutron noise analysis and especially to implement a neutron noise solver in the deterministic transport code APOLLO3 developed at CEA. A new Monte Carlo algorithm that solves the transport equations for the neutron noise has been also developed. In addition, a new vibration model has been developed. Moreover, a method based on the determination of a new steady state has been proposed for the linear and the nonlinear full theory so as to improve the traditional neutron noise theory. In order to test these new developments we have performed neutron noise simulations in one-dimensional systems and in a large pressurized water reactor with heavy baffle in two and three dimensions with APOLLO3 in diffusion and transport theories. (author) [fr

  3. Modification of computational auditory scene analysis (CASA) for noise-robust acoustic feature

    Science.gov (United States)

    Kwon, Minseok

    While there have been many attempts to mitigate interferences of background noise, the performance of automatic speech recognition (ASR) still can be deteriorated by various factors with ease. However, normal hearing listeners can accurately perceive sounds of their interests, which is believed to be a result of Auditory Scene Analysis (ASA). As a first attempt, the simulation of the human auditory processing, called computational auditory scene analysis (CASA), was fulfilled through physiological and psychological investigations of ASA. CASA comprised of Zilany-Bruce auditory model, followed by tracking fundamental frequency for voice segmentation and detecting pairs of onset/offset at each characteristic frequency (CF) for unvoiced segmentation. The resulting Time-Frequency (T-F) representation of acoustic stimulation was converted into acoustic feature, gammachirp-tone frequency cepstral coefficients (GFCC). 11 keywords with various environmental conditions are used and the robustness of GFCC was evaluated by spectral distance (SD) and dynamic time warping distance (DTW). In "clean" and "noisy" conditions, the application of CASA generally improved noise robustness of the acoustic feature compared to a conventional method with or without noise suppression using MMSE estimator. The intial study, however, not only showed the noise-type dependency at low SNR, but also called the evaluation methods in question. Some modifications were made to capture better spectral continuity from an acoustic feature matrix, to obtain faster processing speed, and to describe the human auditory system more precisely. The proposed framework includes: 1) multi-scale integration to capture more accurate continuity in feature extraction, 2) contrast enhancement (CE) of each CF by competition with neighboring frequency bands, and 3) auditory model modifications. The model modifications contain the introduction of higher Q factor, middle ear filter more analogous to human auditory system

  4. Development of a lab-on-chip electrochemical biosensor for water quality analysis based on microalgal photosynthesis.

    Science.gov (United States)

    Tsopela, A; Laborde, A; Salvagnac, L; Ventalon, V; Bedel-Pereira, E; Séguy, I; Temple-Boyer, P; Juneau, P; Izquierdo, R; Launay, J

    2016-05-15

    The present work was dedicated to the development of a lab-on-chip device for water toxicity analysis and more particularly herbicide detection in water. It consists in a portable system for on-site detection composed of three-electrode electrochemical microcells, integrated on a fluidic platform constructed on a glass substrate. The final goal is to yield a system that gives the possibility of conducting double, complementary detection: electrochemical and optical and therefore all materials used for the fabrication of the lab-on-chip platform were selected in order to obtain a device compatible with optical technology. The basic detection principle consisted in electrochemically monitoring disturbances in metabolic photosynthetic activities of algae induced by the presence of Diuron herbicide. Algal response, evaluated through oxygen (O2) monitoring through photosynthesis was different for each herbicide concentration in the examined sample. A concentration-dependent inhibition effect of the herbicide on photosynthesis was demonstrated. Herbicide detection was achieved through a range (blank - 1 µM Diuron herbicide solution) covering the limit of maximum acceptable concentration imposed by Canadian government (0.64 µM), using a halogen white light source for the stimulation of algal photosynthetic apparatus. Superior sensitivity results (limit of detection of around 0.1 µM) were obtained with an organic light emitting diode (OLED), having an emission spectrum adapted to algal absorption spectrum and assembled on the final system. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Distributed system for acquisition and analysis of NPP systems noise data

    International Nuclear Information System (INIS)

    Oprea, F.; Gruia, L.

    2001-01-01

    Since years '90 the noise analysis for nuclear stations is more frequently used because: - the data can be acquired by making use of the NPP instrumentation; - acquisition may be performed in a steady-state regime, at rated capacity; - reactor dynamical regime data are obtainable although steady-state regime data are used. The signal noise analysis is based on the dynamical information about the reactor operation obtained from instrumentation signal fluctuations as determined in steady-system regime. The small fluctuations are due to the stochastic effects inherent to physical processes such as heat transfer, boiling, turbulences in coolant flow, moderator collective motions, fission process, structural vibrations and pressure oscillations. Specifically, for CANDU type reactors, the results may be applied for: - surveillance of the functioning characteristics of detectors and transducers; - signaling or predicting misfunctioning of detectors and transducers, what implies establishment of optimal time rate for macro-sampling; - signaling or prediction of misfunctioning of reactor core components, what implies setting up methods and procedures for detecting vibrations inside the fuel channels, based mainly on the signals from the ROPT adjacent detectors and on the flow rate transducers. The system of signal acquisition is a distributed, fixed-data acquisition system provided with a limited number of inputs, based on a number of modules of local analog signal processing and conversion to digital representation. The signal, local processing implies noise removal out of signal through continuous current component elimination, an amplification of the signal, low-pass filtering for alias frequency removal, 16 bit analog-to-digital conversion and digital value serial way transmission. The local processing is based on the characteristics of the acquired signal (noise), namely: - the frequency band, 0.01 Hz - 200 Hz; - the signal amplitude level, 16 - 32 MeV superimposed

  6. Audible Noise Measurement and Analysis of the Main Power Apparatus in UHV GIS Substations

    Directory of Open Access Journals (Sweden)

    Zhou Nian Guang

    2016-01-01

    Full Text Available Investigation of audible noise characteristics of the main power apparatus in UHV GIS substations provides essential statistics for the noise prediction and control. Noise pressure level, spectrum and attenuation characteristics of the main transformers and high voltage (HV reactors are measured and analyzed in this paper. The result shows that the main transformer and HV reactor have identical A-weighted equivalent sound pressure level. The medium- and low-frequency noises are the primary components in the spectral. More attention should be paid to the low-frequency bands in the noise control process. The noise of cooling fan has a large influence on that of the main transformer. Without the consideration of corona noise, the average A-weighted sound pressure level shows an overall decreasing trend with the increase of the propagation distance. Obvious interference phenomenon of the noises at 100 and 200Hz exists in the noise propagation process.

  7. Electrochemical bond cleavage in pesticide ioxynil. Kinetic analysis by voltammetry and impedance spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Sokolová, R.; Giannarelli, S.; Fanelli, N.; Pospíšil, Lubomír

    2017-01-01

    Roč. 49, SI C (2017), s. 134-138 ISSN 0324-1130 Institutional support: RVO:61388963 Keywords : electrochemical impedance spectroscopy * rate constant * self-protonation * faradaic phase angle * halogen cleavage * EC processes fitting Subject RIV: CG - Electrochemistry OBOR OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis) Impact factor: 0.238, year: 2016

  8. Electrochemical bond cleavage in pesticide ioxynil. Kinetic analysis by voltammetry and impedance spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Sokolová, Romana; Giannarelli, S.; Fanelli, N.; Pospíšil, Lubomír

    2017-01-01

    Roč. 49, C (2017), s. 134-138 ISSN 0324-1130 R&D Projects: GA ČR(CZ) GA14-05180S Institutional support: RVO:61388955 Keywords : electrochemical impedance spectroscopy * rate constant * self-protonation Subject RIV: CG - Electrochemistry OBOR OECD: Physical chemistry Impact factor: 0.238, year: 2016

  9. Electrochemical Analysis of a Novel Ferrocene Derivative as a Potential Antitumor Drug

    Czech Academy of Sciences Publication Activity Database

    Bartošík, M.; Koubková, L.; Karban, Jindřich; Červenková Šťastná, Lucie; Hodík, Tomáš; Lamač, Martin; Pinkas, Jiří; Hrstka, R.

    2015-01-01

    Roč. 140, č. 17 (2015), s. 5864-5867 ISSN 0003-2654 R&D Projects: GA ČR(CZ) GAP207/12/2368 Institutional support: RVO:67985858 ; RVO:61388955 Keywords : electrochemical measurement * sample preparation * nuclear and cytoplasm fraction extraction Subject RIV: CA - Inorganic Chemistry; CF - Physical ; Theoretical Chemistry (UFCH-W) Impact factor: 4.033, year: 2015

  10. An analysis of background noise in selected canyons of Los Alamos County

    Energy Technology Data Exchange (ETDEWEB)

    Huchton, K.; Koch, S.W.; Robinson, R.

    1997-10-01

    The authors recorded background noise levels in six canyons within Los Alamos County in order to establish a baseline for future comparisons and to discover what noises animals are exposed to. Noise level measurements were taken within each canyon, beginning at an established starting point and at one-mile intervals up to four miles. The primary source of noise above 55 dBA was vehicular traffic. One clap of thunder provided the highest recorded noise level (76 dBA). In general, the level of noise, once away from highways and parking lots, was well below 60 dBA.

  11. Electrochemical biosensors

    CERN Document Server

    Cosnier, Serge

    2015-01-01

    "This is an excellent book on modern electrochemical biosensors, edited by Professor Cosnier and written by leading international experts. It covers state-of-the-art topics of this important field in a clear and timely manner."-Prof. Joseph Wang, UC San Diego, USA  "This book covers, in 13 well-illustrated chapters, the potential of electrochemical methods intimately combined with a biological component for the assay of various analytes of biological and environmental interest. Particular attention is devoted to the description of electrochemical microtools in close contact with a biological cell for exocytosis monitoring and to the use of nanomaterials in the electrochemical biosensor architecture for signal improvement. Interestingly, one chapter describes the concept and design of self-powered biosensors derived from biofuel cells. Each topic is reviewed by experts very active in the field. This timely book is well suited for providing a good overview of current research trends devoted to electrochemical...

  12. Application of noise analysis on the operation of the RSG-GAS reactor

    International Nuclear Information System (INIS)

    Surian P, Tukiran S

    1999-01-01

    The RSG-GAS reactor has been operating for radioisotope production and experiments so that it is necessary to perform analysis of the reactor operation. analysis was done based on reactor noise experiment. Neutron noise at low and high power of the RSG-GAS has been analyzed using time and frequency domain with aim to determine the safety of reactor operation. The safety of reactor operation based on two parameters as, prompt neutron decay constant and decay ratio. The parameters are useful for reactor operation, so it is necessary to determine accurately. For determining prompt neutron decay constant, neutron density in the core of reactor which operated at 10 k W, was collected by using Fission Chamber detectors (FC). Based on power spectral density (PSD) was achieved break frequency about 23 Hz, so that the prompt neutron decay constant is about 151 sec -1 . While at at high power 20 MW, neutron density was collected by using Compensated Ionization Chamber (CIC) detector. The result at high power showed that there is reactivity effect in the core because of fluctuation in temperature and density of the coolant, and the decay ratio of 0.20, showed that the reactor is still operation in stable

  13. Electrochemical techniques for practical evaluation of corrosion inhibitor effectiveness. Performance of cerium nitrate as corrosion inhibitor for AA2024T3 alloy

    International Nuclear Information System (INIS)

    Rosero-Navarro, N.C.; Curioni, M.; Bingham, R.; Duran, A.; Aparicio, M.; Cottis, R.A.; Thompson, G.E.

    2010-01-01

    In this work, a split-cell technique and image-assisted electrochemical noise analysis, which provide minimal perturbation of the freely corroding system and good time resolution, are proposed as a tool for simultaneous investigation of the corrosion inhibition mechanism and assessment of performance. The results obtained are compared with results from traditional electrochemical impedance spectroscopy, disclosing the advantages of these techniques in the evaluation of inhibitor performance. Specific attention is also given to the investigation of corrosion inhibition by cerium nitrate.

  14. A full-spectrum analysis of high-speed train interior noise under multi-physical-field coupling excitations

    Science.gov (United States)

    Zheng, Xu; Hao, Zhiyong; Wang, Xu; Mao, Jie

    2016-06-01

    High-speed-railway-train interior noise at low, medium, and high frequencies could be simulated by finite element analysis (FEA) or boundary element analysis (BEA), hybrid finite element analysis-statistical energy analysis (FEA-SEA) and statistical energy analysis (SEA), respectively. First, a new method named statistical acoustic energy flow (SAEF) is proposed, which can be applied to the full-spectrum HST interior noise simulation (including low, medium, and high frequencies) with only one model. In an SAEF model, the corresponding multi-physical-field coupling excitations are firstly fully considered and coupled to excite the interior noise. The interior noise attenuated by sound insulation panels of carriage is simulated through modeling the inflow acoustic energy from the exterior excitations into the interior acoustic cavities. Rigid multi-body dynamics, fast multi-pole BEA, and large-eddy simulation with indirect boundary element analysis are first employed to extract the multi-physical-field excitations, which include the wheel-rail interaction forces/secondary suspension forces, the wheel-rail rolling noise, and aerodynamic noise, respectively. All the peak values and their frequency bands of the simulated acoustic excitations are validated with those from the noise source identification test. Besides, the measured equipment noise inside equipment compartment is used as one of the excitation sources which contribute to the interior noise. Second, a full-trimmed FE carriage model is firstly constructed, and the simulated modal shapes and frequencies agree well with the measured ones, which has validated the global FE carriage model as well as the local FE models of the aluminum alloy-trim composite panel. Thus, the sound transmission loss model of any composite panel has indirectly been validated. Finally, the SAEF model of the carriage is constructed based on the accurate FE model and stimulated by the multi-physical-field excitations. The results show

  15. analysis of the environmental and socio-economic impact of noise

    African Journals Online (AJOL)

    Dr Obe

    Interest in noise control studies is only recent in Nigeria. ... standards for environmental pollution by the Federal ... heaters, gas flare system, reactors, water injection plants, pumps ..... review of health effects of aircraft noise. Aust. NZ J. Public ...

  16. Performance Analysis of Recurrence Matrix Statistics for the Detection of Deterministic Signals in Noise

    National Research Council Canada - National Science Library

    Michalowicz, Joseph V; Nichols, Jonathan M; Bucholtz, Frank

    2008-01-01

    Understanding the limitations to detecting deterministic signals in the presence of noise, especially additive, white Gaussian noise, is of importance for the design of LPI systems and anti-LPI signal defense...

  17. Quantum chemical analysis of Со2+ aqua complexes electrochemical reduction

    Directory of Open Access Journals (Sweden)

    Viktor F. Vargalyuk

    2017-11-01

    Full Text Available Based on the analysis of quantum chemical calculations results (GAMESS, density functional theory, B3LYP method as to [Co(H2On]z(H2O6–n clusters for z = 0, 1, 2 and n=1÷6, it has been demonstrated that electrochemical reduction of [Co(H2O6]2+ aqua complexes runs stage-wise. At the first stage, an electron injected into the [Co(H2O6]2+ complex is entirely located in the orbital of the central atom, as z(Co herewith changes from +1.714 е to +0.777 е. The weakening of Со–ОН2 bonds leads to decomposition of resulting [Co(H2O6]+ particles into two energetically related forms – [Co(H2O4]+ and [Co(H2O3]+. Further reduction of these intermediates runs differently. Electron injection into the [Co(H2O3]+ intermediate terminatesthe transition of Со2+-ions to Со0 z(Co= –0.264 е. This process is accompanied by rapid decomposition of [Co(H2O3]0 product into monohydrate atom of cobalt Со(Н2О. On the contrary, electron injection into the [Co(H2O4]+ intermediate leads to emergence of a specific structure – [Co+(H2O–(Н2О3]¹0, whereby the electron is located in the atoms of cobalt only by 28%, and by 72% in cobalt-coordinated water molecules, clearly focusing on one of the. In this molecule, z(H2O changes from +0.148 е to –0.347 е. There is an assumption that a non-equilibrium [Co+(H2O–(Н2О3]0¹ form transits to [Co(ОH(Н2О3]0 hydroxo-form, which further disproportionates turning into Co(ОH2 hydroxide. In order to reduce the impact of this unfavorable reaction pathway on the overall reaction rate Со2+ + 2ē = Со0, we suggest raising the temperature to ensure complete dissociation of [Co(H2O4]+ to [Co(H2O3]+.

  18. Few-layer graphene sheets with embedded gold nanoparticles for electrochemical analysis of adenine

    Directory of Open Access Journals (Sweden)

    Biris AR

    2013-04-01

    Full Text Available Alexandru R Biris,1 Stela Pruneanu,1 Florina Pogacean,1 Mihaela D Lazar,1 Gheorghe Borodi,1 Stefania Ardelean,1 Enkeleda Dervishi,2 Fumiya Watanabe,2 Alexandru S Biris2 1National Institute for Research and Development of Isotopic and Molecular Technologies, Cluj-Napoca, Romania; 2Center for Integrative Nanotechnology Sciences, University of Arkansas at Little Rock, Little Rock, AR, USA Abstract: This work describes the synthesis of few-layer graphene sheets embedded with various amounts of gold nanoparticles (Gr-Au-x over an Aux/MgO catalytic system (where x = 1, 2, or 3 wt%. The sheet-like morphology of the Gr-Au-x nanostructures was confirmed by transmission electron microscopy and high resolution transmission electron microscopy, which also demonstrated that the number of layers within the sheets varied from two to seven. The sample with the highest percentage of gold nanoparticles embedded within the graphitic layers (Gr-Au-3 showed the highest degree of crystallinity. This distinct feature, along with the large number of edge-planes seen in high resolution transmission electron microscopic images, has a crucial effect on the electrocatalytic properties of this material. The reaction yields (40%–50% and the final purity (96%–98% of the Gr-Au-x composites were obtained by thermogravimetric analysis. The Gr-Au-x composites were used to modify platinum substrates and subsequently to detect adenine, one of the DNA bases. For the bare electrode, no oxidation signal was recorded. In contrast, all of the modified electrodes showed a strong electrocatalytic effect, and a clear peak for adenine oxidation was recorded at approximately +1.05 V. The highest increase in the electrochemical signal was obtained using a platinum/Gr-Au-3-modified electrode. In addition, this modified electrode had an exchange current density (I0, obtained from the Tafel plot one order of magnitude higher than that of the bare platinum electrode, which also confirmed that

  19. Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes

    International Nuclear Information System (INIS)

    Fanjul-Bolado, Pablo; Lamas-Ardisana, Pedro Jose; Hernandez-Santos, David; Costa-Garcia, Agustin

    2009-01-01

    Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0. Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 x 10 -6 M to 1 x 10 -3 M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 x 10 -7 M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10 -5 M acetaminophen and do not present any memory effect. Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products.

  20. Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Fanjul-Bolado, Pablo [DropSens, S.L., Edificio Severo Ochoa, Campus El Cristo, 33006 Oviedo, Asturias (Spain); Lamas-Ardisana, Pedro Jose [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, Julian Claveria 8, 33006 Oviedo, Asturias (Spain); Hernandez-Santos, David [DropSens, S.L., Edificio Severo Ochoa, Campus El Cristo, 33006 Oviedo, Asturias (Spain); Costa-Garcia, Agustin, E-mail: costa@fq.uniovi.es [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, Julian Claveria 8, 33006 Oviedo, Asturias (Spain)

    2009-04-13

    Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0. Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 x 10{sup -6} M to 1 x 10{sup -3} M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 x 10{sup -7} M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10{sup -5} M acetaminophen and do not present any memory effect. Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products.

  1. The forgotten effect of the finite measurement time on various noise analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wallerbos, E.J.M.; Hoogenboom, J.E

    1998-06-01

    The conventional noise analysis expressions for functions like the auto- and cross-correlation function, the variance to mean ratio, and the Rossi-{alpha} formula, diverge when the reactor is critical. This problem arises because one pole of the zero-power reactor transfer function is zero. However, in a finite measurement time, a zero frequency cannot be measured and the divergence will not be found experimentally. New expressions for the expectation values of the experimental quantities of various pulse counting techniques are derived which also take into account the dead time of the detector. These expressions do not suffer from divergence at critical. A Feynman-{alpha} experiment is simulated in two, neutronically different systems. The use of the conventional equations for the analysis of the experiments is seen to lead to a bias in the inferred reactivity value.

  2. Nuclear reactor pump diagnostics via noise analysis/artificial neural networks

    International Nuclear Information System (INIS)

    Keyvan, S.; Rabelo, L.C.

    1991-01-01

    A feasibility study is performed on the utilization of artificial neural networks as a tool for reactor diagnostics. Reactor pump signals utilized in a wear-out monitoring system developed for early detection of degradation of pump shaft are analyzed as a semi-benchmark test to study the feasibility of neural networks for pattern recognition. The Adaptive Resonance Theory (ART 2) paradigm of artificial neural networks is applied in this study. The signals are collected signals as well as generated signals simulating the wear progress. The wear-out monitoring system applies noise analysis techniques, and is capable of distinguishing between these signals and providing a measure of the progress of the degradation. This paper presents the results of the analysis of these data via the ART 2 paradigm

  3. A temporal and spatial analysis of anthropogenic noise sources affecting SNMR

    Science.gov (United States)

    Dalgaard, E.; Christiansen, P.; Larsen, J. J.; Auken, E.

    2014-11-01

    One of the biggest challenges when using the surface nuclear magnetic resonance (SNMR) method in urban areas is a relatively low signal level compared to a high level of background noise. To understand the temporal and spatial behavior of anthropogenic noise sources like powerlines and electric fences, we have developed a multichannel instrument, noiseCollector (nC), which measures the full noise spectrum up to 10 kHz. Combined with advanced signal processing we can interpret the noise as seen by a SNMR instrument and also obtain insight into the more fundamental behavior of the noise. To obtain a specified acceptable noise level for a SNMR sounding the stack size can be determined by quantifying the different noise sources. Two common noise sources, electromagnetic fields stemming from powerlines and fences are analyzed and show a 1/r2 dependency in agreement with theoretical relations. A typical noise map, obtained with the nC instrument prior to a SNMR field campaign, clearly shows the location of noise sources, and thus we can efficiently determine the optimal location for the SNMR sounding from a noise perspective.

  4. An Analysis of 1/f2 Phase Noise in Bipolar Colpitts Oscillators (With a Digression on Bipolar Differential-Pair LC Oscillators)

    DEFF Research Database (Denmark)

    Fard, A.; Andreani, Pietro

    2007-01-01

    This work presents an analysis of phase noise in the $1/f^{2}$ region displayed by both single-ended and differential bipolar Colpitts oscillators. Very accurate and rigorous symbolic phase noise expressions are derived, enabling a deeper insight into the major mechanisms of phase noise generatio......, and providing new tools for design optimization. Phase noise expressions for the cross-coupled differential-pair LC-tank oscillator are derived as well....

  5. Analysis of transport phenomena and electrochemical reactions in a micro PEM fuel cell

    OpenAIRE

    Maher A.R. Sadiq Al-Baghdadi

    2014-01-01

    Micro-fuel cells are considered as promising electrochemical power sources in portable electronic devices. The presence of microelectromechanical system (MEMS) technology makes it possible to manufacture the miniaturized fuel cell systems. The majority of research on micro-scale fuel cells is aimed at micro-power applications. Performance of micro-fuel cells are closely related to many factors, such as designs and operating conditions. CFD modeling and simulation for heat and mass transport i...

  6. Electrochemical Analysis of Antichemotherapeutic Drug Zanosar in Pharmaceutical and Biological Samples by Differential Pulse Polarography

    OpenAIRE

    Reddy, Chennupalle Nageswara; ReddyPrasad, Puthalapattu; Sreedhar, NeelamYughandhar

    2013-01-01

    The electrochemical reduction of zanosar was investigated systematically by direct current polarography, cyclic voltammetry, and differential pulse polarography (DPP). A simple DPP technique was proposed for the direct quantitative determination of anticancer drug zanosar in pharmaceutical formulation and spiked human urine samples for the first time. The reduction potential was −0.28 V versus Ag/AgCl with a hanging mercury drop electrode in Britton-Robinson buffer as supporting electrolyte. ...

  7. Prediction of interior noise due to random acoustic or turbulent boundary layer excitation using statistical energy analysis

    Science.gov (United States)

    Grosveld, Ferdinand W.

    1990-01-01

    The feasibility of predicting interior noise due to random acoustic or turbulent boundary layer excitation was investigated in experiments in which a statistical energy analysis model (VAPEPS) was used to analyze measurements of the acceleration response and sound transmission of flat aluminum, lucite, and graphite/epoxy plates exposed to random acoustic or turbulent boundary layer excitation. The noise reduction of the plate, when backed by a shallow cavity and excited by a turbulent boundary layer, was predicted using a simplified theory based on the assumption of adiabatic compression of the fluid in the cavity. The predicted plate acceleration response was used as input in the noise reduction prediction. Reasonable agreement was found between the predictions and the measured noise reduction in the frequency range 315-1000 Hz.

  8. Model Based Analysis of Forced and Natural Convection Effects in an Electrochemical Cell

    Directory of Open Access Journals (Sweden)

    D Brunner

    2017-03-01

    Full Text Available High purity copper, suitable for electrical applications, can only be obtained by electro-winning. The hallmark of this process is its self-induced natural convection through density variations of the electrolyte at both anode and cathode. In order to do this, first the full dynamic complexity of the process needs to be understood. Thus an OpenFoam®-based 2D model of the process has been created. This finite-volume multiphysics approach solves the laminar momentum and copper-ion species conservation equations, as well as local copper-ion conversion kinetics. It uses a Boussinesq approximation to simulate the species-momentum coupling, namely natural draft forces induced by variations of the spatial copper concentration within the fluid. The model shows good agreement with benchmark-cases of real-life electrochemical cells found in literature. An additional flow was imposed at the bottom of a small scale electrochemical cell in order to increase the ionic transport and thereby increase the overall performance of the cell. In a small scale electrochemical cell in strictly laminar flow, the overall performance could be increased and stratification decreased.

  9. Noise analysis due to strip resistance in the ATLAS SCT silicon strip module

    International Nuclear Information System (INIS)

    Kipnis, I.

    1996-08-01

    The module is made out of four 6 cm x 6 cm single sided Si microstrip detectors. Two detectors are butt glued to form a 12 cm long mechanical unit and strips of the two detectors are electrically connected to form 12 cm long strips. The butt gluing is followed by a back to back attachment. The module in this note is the Rφ module where the electronics is oriented parallel to the strip direction and bonded directly to the strips. This module concept provides the maximum signal-to-noise ratio, particularly when the front-end electronics is placed near the middle rather than at the end. From the noise analysis, it is concluded that the worst-case ΔENC (far-end injection) between end- and center-tapped modules will be 120 to 210 el. rms (9 to 15%) for a non-irradiated detector and 75 to 130 el. rms (5 to 9%) for an irradiated detector, for a metal strip resistance of 10 to 20 Ω/cm

  10. An analysis of error patterns in children′s backward digit recall in noise

    Directory of Open Access Journals (Sweden)

    Homira Osman

    2015-01-01

    Full Text Available The purpose of the study was to determine whether perceptual masking or cognitive processing accounts for a decline in working memory performance in the presence of competing speech. The types and patterns of errors made on the backward digit span in quiet and multitalker babble at -5 dB signal-to-noise ratio (SNR were analyzed. The errors were classified into two categories: item (if digits that were not presented in a list were repeated and order (if correct digits were repeated but in an incorrect order. Fifty five children with normal hearing were included. All the children were aged between 7 years and 10 years. Repeated measures of analysis of variance (RM-ANOVA revealed the main effects for error type and digit span length. In terms of listening condition interaction, it was found that the order errors occurred more frequently than item errors in the degraded listening condition compared to quiet. In addition, children had more difficulty recalling the correct order of intermediate items, supporting strong primacy and recency effects. Decline in children′s working memory performance was not primarily related to perceptual difficulties alone. The majority of errors was related to the maintenance of sequential order information, which suggests that reduced performance in competing speech may result from increased cognitive processing demands in noise.

  11. An analysis of error patterns in children's backward digit recall in noise

    Science.gov (United States)

    Osman, Homira; Sullivan, Jessica R.

    2015-01-01

    The purpose of the study was to determine whether perceptual masking or cognitive processing accounts for a decline in working memory performance in the presence of competing speech. The types and patterns of errors made on the backward digit span in quiet and multitalker babble at -5 dB signal-to-noise ratio (SNR) were analyzed. The errors were classified into two categories: item (if digits that were not presented in a list were repeated) and order (if correct digits were repeated but in an incorrect order). Fifty five children with normal hearing were included. All the children were aged between 7 years and 10 years. Repeated measures of analysis of variance (RM-ANOVA) revealed the main effects for error type and digit span length. In terms of listening condition interaction it was found that the order errors occurred more frequently than item errors in the degraded listening condition compared to quiet. In addition, children had more difficulty recalling the correct order of intermediate items, supporting strong primacy and recency effects. Decline in children's working memory performance was not primarily related to perceptual difficulties alone. The majority of errors was related to the maintenance of sequential order information, which suggests that reduced performance in competing speech may result from increased cognitive processing demands in noise. PMID:26168949

  12. Wind turbine airfoil design method with low noise and experimental analysis

    DEFF Research Database (Denmark)

    Wang, Quan; Chen, Jin; Cheng, Jiangtao

    2015-01-01

    In order to study the noise characteristic of wind turbine airfoils, the airfoil optimal design mathematic model was built based on airfoil functional integrated theory and noise calculated model. The new optimized objective function of maximizing lift/drag to noise was developed on the design......, though there is a certain difference between the theory results and experiment data. Compared with NACA-64-618 airfoil, the CQU-DTU-B18 airfoil exhibits lower noise, which validates the feasibility of this design method. It is a guide to design wind turbine airfoil with lower noise and to reduce airfoil...

  13. Active Control of Fan Noise: Feasibility Study. Volume 6; Theoretical Analysis for Coupling of Active Noise Control Actuator Ring Sources to an Annular Duct with Flow

    Science.gov (United States)

    Kraft, R. E.

    1996-01-01

    The objective of this effort is to develop an analytical model for the coupling of active noise control (ANC) piston-type actuators that are mounted flush to the inner and outer walls of an annular duct to the modes in the duct generated by the actuator motion. The analysis will be used to couple the ANC actuators to the modal analysis propagation computer program for the annular duct, to predict the effects of active suppression of fan-generated engine noise sources. This combined program will then be available to assist in the design or evaluation of ANC systems in fan engine annular exhaust ducts. An analysis has been developed to predict the modes generated in an annular duct due to the coupling of flush-mounted ring actuators on the inner and outer walls of the duct. The analysis has been combined with a previous analysis for the coupling of modes to a cylindrical duct in a FORTRAN computer program to perform the computations. The method includes the effects of uniform mean flow in the duct. The program can be used for design or evaluation purposes for active noise control hardware for turbofan engines. Predictions for some sample cases modeled after the geometry of the NASA Lewis ANC Fan indicate very efficient coupling in both the inlet and exhaust ducts for the m = 6 spinning mode at frequencies where only a single radial mode is cut-on. Radial mode content in higher order cut-off modes at the source plane and the required actuator displacement amplitude to achieve 110 dB SPL levels in the desired mode were predicted. Equivalent cases with and without flow were examined for the cylindrical and annular geometry, and little difference was found for a duct flow Mach number of 0.1. The actuator ring coupling program will be adapted as a subroutine to the cylindrical duct modal analysis and the exhaust duct modal analysis. This will allow the fan source to be defined in terms of characteristic modes at the fan source plane and predict the propagation to the

  14. Coherent network analysis technique for discriminating gravitational-wave bursts from instrumental noise

    International Nuclear Information System (INIS)

    Chatterji, Shourov; Lazzarini, Albert; Stein, Leo; Sutton, Patrick J.; Searle, Antony; Tinto, Massimo

    2006-01-01

    The sensitivity of current searches for gravitational-wave bursts is limited by non-Gaussian, nonstationary noise transients which are common in real detectors. Existing techniques for detecting gravitational-wave bursts assume the output of the detector network to be the sum of a stationary Gaussian noise process and a gravitational-wave signal. These techniques often fail in the presence of noise nonstationarities by incorrectly identifying such transients as possible gravitational-wave bursts. Furthermore, consistency tests currently used to try to eliminate these noise transients are not applicable to general networks of detectors with different orientations and noise spectra. In order to address this problem we introduce a fully coherent consistency test that is robust against noise nonstationarities and allows one to distinguish between gravitational-wave bursts and noise transients in general detector networks. This technique does not require any a priori knowledge of the putative burst waveform

  15. Analysis of plasma microRNA expression profiles in male textile workers with noise-induced hearing loss.

    Science.gov (United States)

    Ding, Lu; Liu, Jing; Shen, Huan-Xi; Pan, Li-Ping; Liu, Qing-Dong; Zhang, Heng-Dong; Han, Lei; Shuai, Li-Guo; Ding, En-Min; Zhao, Qiu-Ni; Wang, Bo-Shen; Zhu, Bao-Li

    2016-03-01

    Circulating microRNAs (miRNAs) have attracted interests as non-invasive biomarkers of physiological and pathological conditions, which may be applied in noise-induced hearing loss (NIHL). However, no epidemiology studies have yet examined the potential effects of NIHL or noise exposure on miRNA expression profiles. We sought to identify permanent NIHL-related miRNAs and to predict the biological functions of the putative genes encoding the indicated miRNAs. In the discovery stage, we used a microarray assay to detect the miRNA expression profiles between pooled plasma samples from 10 noise-exposed individuals with normal hearing and 10 NIHL patients. In addition, we conducted a preliminary validation of six candidate miRNAs in the same 20 workers. Subsequently, three miRNAs were selected for expanded validation in 23 non-exposed individuals with normal hearing and 46 noise-exposed textile workers which including 23 noise-exposed workers with normal hearing and 23 NIHL patients. Moreover, we predicted the biological functions of the putative target genes using a Gene Ontology (GO) function enrichment analysis. In the discovery stage, compared with the noise exposures with normal hearing, 73 miRNAs demonstrated at least a 1.5-fold differential expression in the NIHL patients. In the preliminary validation, compared with the noise exposures, the plasma levels of miR-16-5p, miR-24-3p, miR-185-5p and miR-451a were all upregulated (P < 0.001) in the NIHL patients. In the expanded validation stage, compared with the non-exposures, the plasma levels of miR-24, miR-185-5p and miR-451a were all significantly downregulated (P < 0.001) in the exposures. And compared with the noise exposures, the plasma levels of miR-185-5p and miR-451a were slightly elevated (P < 0.001) in the NIHL patients, which were consistent with the results of preliminary validation and microarray analysis. The two indicated plasma miRNAs may be biomarkers of indicating responses to noise exposure

  16. Electrochemical Processes

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers

    1997-01-01

    The notes describe in detail primary and secondary galvanic cells, fuel cells, electrochemical synthesis and electroplating processes, corrosion: measurments, inhibitors, cathodic and anodic protection, details of metal dissolution reactions, Pourbaix diagrams and purification of waste water from...

  17. Association between exposure to noise and risk of hypertension: a meta-analysis of observational epidemiological studies.

    Science.gov (United States)

    Fu, Wenning; Wang, Chao; Zou, Li; Liu, Qiaoyan; Gan, Yong; Yan, Shijiao; Song, Fujian; Wang, Zhihong; Lu, Zuxun; Cao, Shiyi

    2017-12-01

    An increasing amount of original studies suggested that exposure to noise could be associated with the risk of hypertension, but the results remain inconsistent and inconclusive. We aimed to synthesize available epidemiological evidence about the relationship between various types of noise and hypertension, and to explore the potential dose-response relationship between them in an up-to-date meta-analysis. We conducted a literature search of PubMed and Embase from these databases' inception through December 2016 to identify observational epidemiological studies examining the association between noise and risk of hypertension. A random effects model was used to combine the results of included studies. Dose-response meta-analysis was conducted to examine the potential dose-response relationship. In total, 32 studies (five cohort studies, one case-control study, and 26 cross-section studies) involving 264 678 participants were eligible for inclusion. Pooled result showed that living or working in environment with noise exposure was significantly associated with increased risk of hypertension (odds ratio 1.62; 95% confidence interval: 1.40-1.88). We found no evidence of a curve linear association between noise and risk of hypertension. A dose-response analysis suggested that, for an increment of per 10 dB(A) of noise, the combined odds ratio of hypertension was 1.06 (95% confidence interval: 1.04-1.08). Integrated epidemiological evidence supports the hypothesis that exposure to noise may be a risk factor of hypertension, and there is a positive dose-response association between them.

  18. Variability of signal-to-noise ratio and the network analysis of gravitational wave burst signals

    International Nuclear Information System (INIS)

    Mohanty, S D; Rakhmanov, M; Klimenko, S; Mitselmakher, G

    2006-01-01

    The detection and estimation of gravitational wave burst signals, with a priori unknown polarization waveforms, requires the use of data from a network of detectors. Maximizing the network likelihood functional over all waveforms and sky positions yields point estimates for them as well as a detection statistic. However, the transformation from the data to estimates can become ill-conditioned over parts of the sky, resulting in significant errors in estimation. We modify the likelihood procedure by introducing a penalty functional which suppresses candidate solutions that display large signal-to-noise ratio (SNR) variability as the source is displaced on the sky. Simulations show that the resulting network analysis method performs significantly better in estimating the sky position of a source. Further, this method can be applied to any network, irrespective of the number or mutual alignment of detectors

  19. Analysis and Optimal Condition of the Rear-Sound-Aided Control Source in Active Noise Control

    Directory of Open Access Journals (Sweden)

    Karel Kreuter

    2011-01-01

    Full Text Available An active noise control scenario of simple ducts is considered. The previously suggested technique of using an single loudspeaker and its rear sound to cancel the upstream sound is further examined and compared to the bidirectional solution in order to give theoretical proof of its advantage. Firstly, a model with a new approach for taking damping effects into account is derived based on the electrical transmission line theory. By comparison with the old model, the new approach is validated, and occurring differences are discussed. Moreover, a numerical application with the consideration of damping is implemented for confirmation. The influence of the rear sound strength on the feedback-path system is investigated, and the optimal condition is determined. Finally, it is proven that the proposed source has an advantage of an extended phase lag and a time delay in the feedback-path system by both frequency-response analysis and numerical calculation of the time response.

  20. Input-output analysis of high-speed axisymmetric isothermal jet noise

    Science.gov (United States)

    Jeun, Jinah; Nichols, Joseph W.; Jovanović, Mihailo R.

    2016-04-01

    We use input-output analysis to predict and understand the aeroacoustics of high-speed isothermal turbulent jets. We consider axisymmetric linear perturbations about Reynolds-averaged Navier-Stokes solutions of ideally expanded turbulent jets with jet Mach numbers 0.6 parabolized stability equations (PSE), and this mode dominates the response. For subsonic jets, however, the singular values indicate that the contributions of sub-optimal modes to noise generation are nearly equal to that of the optimal mode, explaining why the PSE do not fully capture the far-field sound in this case. Furthermore, high-fidelity large eddy simulation (LES) is used to assess the prevalence of sub-optimal modes in the unsteady data. By projecting LES source term data onto input modes and the LES acoustic far-field onto output modes, we demonstrate that sub-optimal modes of both types are physically relevant.

  1. Input-output analysis of high-speed turbulent jet noise

    Science.gov (United States)

    Jeun, Jinah; Nichols, Joseph W.

    2015-11-01

    We apply input-output analysis to predict and understand the aeroacoustics of high-speed isothermal turbulent jets. We consider axisymmetric linear perturbations about Reynolds-averaged Navier-Stokes solutions of ideally expanded turbulent jets with Mach numbers 0 . 6 parabolized stability equations (PSE), and this mode dominates the response. For subsonic jets, however, the singular values indicate that the contributions of suboptimal modes to noise generation are nearly equal to that of the optimal mode, explaining why PSE misses some of the farfield sound in this case. Finally, high-fidelity large eddy simulation (LES) is used to assess the prevalence of suboptimal modes in the unsteady data. By projecting LES data onto the corresponding input modes, the weighted gain of each mode is examined.

  2. Detecting periodic oscillations in astronomy data: revisiting wavelet analysis with coloured and white noise

    Science.gov (United States)

    Xu, Chang

    2017-04-01

    The intrinsic random variability of an astronomical source hampers the detection of possible periodicities that we are interested in. We find that a simple first-order autoregressive [AR(1)] process gives a poor fit to the power decay in the observed spectrum for astrophysical sources and geodetic observations. Thus, appropriate background noise models have to be chosen for significance tests to distinguish real features from the intrinsic variability of the source. Here we recall the wavelet analysis with significance and confidence testing but extend it with the generalized Gauss Markov stochastic model as the null hypothesis, which includes AR(1) and a power law as special cases. We exemplify this discussion with real data, such as sunspot number data, geomagnetic indices, X-ray observations, as well as a Global Positioning System (GPS) position time series.

  3. Graph theory applied to noise and vibration control in statistical energy analysis models.

    Science.gov (United States)

    Guasch, Oriol; Cortés, Lluís

    2009-06-01

    A fundamental aspect of noise and vibration control in statistical energy analysis (SEA) models consists in first identifying and then reducing the energy flow paths between subsystems. In this work, it is proposed to make use of some results from graph theory to address both issues. On the one hand, linear and path algebras applied to adjacency matrices of SEA graphs are used to determine the existence of any order paths between subsystems, counting and labeling them, finding extremal paths, or determining the power flow contributions from groups of paths. On the other hand, a strategy is presented that makes use of graph cut algorithms to reduce the energy flow from a source subsystem to a receiver one, modifying as few internal and coupling loss factors as possible.

  4. Analysis of piezoelectric energy harvester under modulated and filtered white Gaussian noise

    Science.gov (United States)

    Quaranta, Giuseppe; Trentadue, Francesco; Maruccio, Claudio; Marano, Giuseppe C.

    2018-05-01

    This paper proposes a comprehensive method for the electromechanical probabilistic analysis of piezoelectric energy harvesters subjected to modulated and filtered white Gaussian noise (WGN) at the base. Specifically, the dynamic excitation is simulated by means of an amplitude-modulated WGN, which is filtered through the Clough-Penzien filter. The considered piezoelectric harvester is a cantilever bimorph modeled as Euler-Bernoulli beam with a concentrated mass at the free-end, and its global behavior is approximated by the fundamental vibration mode (which is tuned with the dominant frequency of the dynamic input). A resistive electrical load is considered in the circuit. Once the Lyapunov equation of the coupled electromechanical problem has been formulated, an original and efficient semi-analytical procedure is proposed to estimate mean and standard deviation of the electrical energy extracted from the piezoelectric layers.

  5. Background reduction and noise discrimination in the proportional counting of tritium using pulse-shape analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hochel, R C; Hayes, D W [Du Pont de Nemours (E.I.) and Co., Aiken, S.C. (USA). Savannah River Lab.

    1975-12-01

    A pulse-shape analysis (PSA) unit of commercial design has been incorporated into a proportional counting system to determine the effectiveness of pulse-shape discrimination in increasing the sensitivity of tritium counting. It was found that a quantitative determination of tritium could be obtained directly from the PSA time spectrum eliminating the need for beta-ray energy selection used in the pulse-shape discrimination (PSD) technique. The performance of the proportional counting system was tested using the PSA unit and anticoincidence shielding, both singly and combined, under several types of background. A background reduction factor of 169 was obtained from the combined PSA-anticoincidence system with only a 2% loss in tritium counting efficiency. The PSA method was also found to offer significant reductions in noise background.

  6. Background reduction and noise discrimination in the proportional counting of tritium using pulse-shape analysis

    International Nuclear Information System (INIS)

    Hochel, R.C.; Hayes, D.W.

    1975-01-01

    A pulse-shape analysis (PSA) unit of commercial design has been incorporated into a proportional counting system to determine the effectiveness of pulse-shape discrimination in increasing the sensitivity of tritium counting. It was found that a quantitative determination of tritium could be obtained directly from the PSA time spectrum eliminating the need for beta-ray energy selection used in the pulse-shape discrimination (PSD) technique. The performance of the proportional counting system was tested using the PSA unit and anticoincidence shielding, both singly and combined, under several types of background. A background reduction factor of 169 was obtained from the combined PSA-anticoincidence system with only a 2% loss in tritium counting efficiency. The PSA method was also found to offer significant reductions in noise background. (Auth.)

  7. Contrast to Noise Ratio and Contrast Detail Analysis in Mammography:A Monte Carlo Study

    International Nuclear Information System (INIS)

    Metaxas, V; Delis, H; Panayiotakis, G; Kalogeropoulou, C; Zampakis, P

    2015-01-01

    The mammographic spectrum is one of the major factors affecting image quality in mammography. In this study, a Monte Carlo (MC) simulation model was used to evaluate image quality characteristics of various mammographic spectra. The anode/filter combinations evaluated, were those traditionally used in mammography, for tube voltages between 26 and 30 kVp. The imaging performance was investigated in terms of Contrast to Noise Ratio (CNR) and Contrast Detail (CD) analysis, by involving human observers, utilizing a mathematical CD phantom. Soft spectra provided the best characteristics in terms of both CNR and CD scores, while tube voltage had a limited effect. W-anode spectra filtered with k-edge filters demonstrated an improved performance, that sometimes was better compared to softer x-ray spectra, produced by Mo or Rh anode. Regarding the filter material, k-edge filters showed superior performance compared to Al filters. (paper)

  8. Physics of the 252Cf-source-driven noise analysis measurement

    International Nuclear Information System (INIS)

    Valentine, T.E.; Mihalczo, J.T.; Perez, R.B.; Mattingly, J.K.

    1997-01-01

    The 252 Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method's broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, coherences, and ratios of spectral densities. All of these measured parameters can also be calculated using the MCNP-DSP Monte Carlo code. This paper presents a review of the time-domain signatures obtained from this measurement

  9. Application of a coupled kinetics-thermalhydraulic computer model to noise analysis

    International Nuclear Information System (INIS)

    Miguel Cecenas Falcon; Rina M Campos-Gonzalez; Edmundo del Valle Gallegos

    2005-01-01

    Full text of publication follows: Noise analysis is a common tool to evaluate dynamic properties of a Boiling Water Reactor using the power measurements provided by the nuclear instrumentation, such as LPRMs. Stability monitors use noise analysis to evaluate the system decay ratio, and they require a large amount of data in order to test and validate the algorithms and produce reliable monitoring. Because a nuclear reactor normally operates at or near nominal conditions, the amount of interesting stationary data at relatively low power is limited. There are very important stability benchmarks that recorded power for a number of cases involving operation close to the stability boundary, and even during a fully developed limit cycle, but in general there is a limited amount of data at points of interest in the power and flow map, to be used for stability studies. Under this limitation, a model that can generate all the required information for any point in the power and flow map is useful. Particular importance has the capacity to generate time series equivalent to noisy LPRM signals close to the natural circulation line, and test the early detection of still incipient out of phase oscillations in the core. In order to generate these signals, a model of 36 parallel boiling channels is prepared to reproduce the benchmark conditions of the Ringhals core at test point 9 during cycle 14. Each channel considers one phase region, subcooled boiling and bulk boiling. The power, flow and average void fraction at each of the 36 channel were reproduced to define a stationary model which is perturbed with additive white noise in order to generate void fraction fluctuations. The cross sections are a function of void fractions, hence the fluctuations are transmitted to the neutronics and finally to the power. The power fluctuations are analog to those produced by bubble generation and collapsing during the boiling process. The neutronics is modeled with a two-dimensional nodal

  10. Development of a noise reduction program of a prompt gamma spectrum based on principal component analysis for an explosive detection

    International Nuclear Information System (INIS)

    Lee, Yun Hee; Im, Hee Jung; Song, Byung ChoI; Park, Yong Joon; Kim, Won Ho; Cho, Jung Hwan

    2005-01-01

    This work demonstrates a developed program to reduce noises of a prompt gamma-ray spectrum measured by irradiating neutrons into baggage. The noises refer to random variations mainly caused by electrical fluctuations and also by a measurement time. Especially, since the short measurement time yields such a noisy spectrum in which its special peak can not be observed, it is necessary to extract its characteristic signals from the spectrum to identify an explosive hidden in luggage. Principal component analysis(PCA) that is a multivariate statistical technique is closely related to singular value decomposition(SVD). The SVD-based PCA decreases the noise by reconstructing the spectrum after determining the number of principal components corresponding important signals based on the history data that sufficiently describe its population. In this study, we present a visualized program of the above procedure using the MATLAB 7.04 programming language. When our program is started, it requires an arbitrary measured spectrum to be reduced and history spectra as input files. If user selects the files with menu, our program automatically carries out the PCA procedure and provides its noise-reduced spectrum plot as well as the original spectrum plot into an output window. In addition, user can obtain signal-to-noise ratio of an interesting peak by defining the peak and noise ranges with menu

  11. Noise Gating Solar Images

    Science.gov (United States)

    DeForest, Craig; Seaton, Daniel B.; Darnell, John A.

    2017-08-01

    I present and demonstrate a new, general purpose post-processing technique, "3D noise gating", that can reduce image noise by an order of magnitude or more without effective loss of spatial or temporal resolution in typical solar applications.Nearly all scientific images are, ultimately, limited by noise. Noise can be direct Poisson "shot noise" from photon counting effects, or introduced by other means such as detector read noise. Noise is typically represented as a random variable (perhaps with location- or image-dependent characteristics) that is sampled once per pixel or once per resolution element of an image sequence. Noise limits many aspects of image analysis, including photometry, spatiotemporal resolution, feature identification, morphology extraction, and background modeling and separation.Identifying and separating noise from image signal is difficult. The common practice of blurring in space and/or time works because most image "signal" is concentrated in the low Fourier components of an image, while noise is evenly distributed. Blurring in space and/or time attenuates the high spatial and temporal frequencies, reducing noise at the expense of also attenuating image detail. Noise-gating exploits the same property -- "coherence" -- that we use to identify features in images, to separate image features from noise.Processing image sequences through 3-D noise gating results in spectacular (more than 10x) improvements in signal-to-noise ratio, while not blurring bright, resolved features in either space or time. This improves most types of image analysis, including feature identification, time sequence extraction, absolute and relative photometry (including differential emission measure analysis), feature tracking, computer vision, correlation tracking, background modeling, cross-scale analysis, visual display/presentation, and image compression.I will introduce noise gating, describe the method, and show examples from several instruments (including SDO

  12. Analysis of noise pollution level in a University campus in South India

    Science.gov (United States)

    Thattai, D.; Sudarsan, J. S.; Sathyanathan, R.; Ramasamy, Visalatchi

    2017-07-01

    Noise comprises those sounds occurring around us that are not part of the environment under consideration. Noise is also a type of pollution and impacts on our health and wellness. The prevalence of noise is increasing in magnitude and severity because of growing population and urbanization. Noise pollution leads to many chronic and socially significant impacts. This study analyzes the level of noise at different points in SRM University. As the University encompasses a hospital also, it is more important to identify the sources of high noise levels and control them. As per Indian standards the desirable noise pollution for educational institutions and hospitals in daytime is 50 dbA. Noise levels were measured with a sound level meter at 19 points within the campus at three different timings (8-10 am, 12-2 pm, and 3-5 pm) over two cycles of measurements. The preliminary results show higher noise levels during morning and evening. Noise during Cycle 2 (latter half of semester) was 20% more compared to that of Cycle 1 (beginning of semester).

  13. Noise Sensitivities in Dogs: An Exploration of Signs in Dogs with and without Musculoskeletal Pain Using Qualitative Content Analysis

    Directory of Open Access Journals (Sweden)

    Ana Luisa Lopes Fagundes

    2018-02-01

    Full Text Available Noise sensitivity is a common behaviour problem in dogs. In humans, there is a well-established relationship between painful conditions and the development of fear-related avoidance responses. Whilst it is likely that a relationship exists between noise sensitivity and pain in dogs, this does not appear to have been investigated. The aim of this study was to explore the signs of noise sensitivity in dogs with and without musculoskeletal pain by comparing case histories using qualitative content analysis. Data were extracted from the clinical records of 20 cases of dogs presenting with noise sensitivity seen by clinical animal behaviourists at the University of Lincoln, composed of 2 groups—10 “clinical cases” with pain and 10 “control cases” without pain. Loud noises as a trigger of noise sensitivity were a common theme in both groups but ubiquitous among “clinical cases.” In “clinical cases” (i.e., those where pain was identified, the age of onset of the noise sensitivity was on average nearly 4 years later than “control cases.” In addition, strong themes emerged relating to widespread generalisation to associated environments and avoidance of other dogs in the “clinical cases,” which did not appear in the “control cases.” “Clinical cases” responded well to treatment once the involvement of pain had been identified. Veterinarians and behaviourists should carefully assess dogs with noise sensitivities for pain-related problems especially if presenting with these characteristics.

  14. Service water electrochemical monitoring development at Ontario Hydro

    International Nuclear Information System (INIS)

    Brennenstuhl, A.M.

    1994-01-01

    Ontario Hydro (OH) is currently investigating the feasibility of using electrochemical techniques for the corrosion monitoring of service water systems. To date all evaluations have been carried out in a field simulator. The studies include examining the effects of; system startup after periods of stagnation, sodium hypochlorite injection, and zebra mussel settlement on metallic surfaces. Carbon steel and Type 304L stainless steel have been evaluated. Electrochemical potential noise (EPN), electrochemical current noise (ECN) potential and coupling current were semi-continuously monitored over a period of up to one year. Data obtained from the electrochemical noise monitoring has given OH valuable insights into the mechanisms of degradation in service water systems. The high sensitivity of the electrochemical noise technique, particularly to localized corrosion has proved to be the major attraction of the system

  15. Noise analysis of Forsmark 1 data to investigate BWR core local instability

    International Nuclear Information System (INIS)

    Oguma, R.

    1998-04-01

    BWR core local instability was experienced at Forsmark 1 (F1) during reactor operation in cycle 16. The event has been studied by applying noise analysis and stability calculations to get insight into the event as well as to identify the cause of local instability. The present report is concerned with noise analysis of data collected during start-up in cycle 17. The results of the current study indicates: The F1 core is quite stable in cycle 17. The max. decay ratio (DR) value of 0.37 was obtained from the stability evaluation of an APRM (average power range monitor) and LPRM (local power range monitor) signals measured at 66% (APRM) of reactor power and 4252 Kg/s (SA-HC) of core flow. Compared with the power profile in cycle 17 (as well as in reactor F2), the core in cycle 16 had an extreme power profile with high power and bottom-shifted axial peak in the core periphery esp. at the four quadrant corners. Such a profile decreases the stability margin in the region. It is a common observation that the DR obtained from APRM tends to be higher than that from LPRM if the global instability mechanism is dominant in the core, and vice versa. The comparison of global and local DR values should be an effective method for detecting local instability during the reactor operation. In order to detect the local instability it is important to evaluate the core stability with sufficient number of LPRMs so as to cover the whole core cross section together with APRMs

  16. Noise-tolerant inverse analysis models for nondestructive evaluation of transportation infrastructure systems using neural networks

    Science.gov (United States)

    Ceylan, Halil; Gopalakrishnan, Kasthurirangan; Birkan Bayrak, Mustafa; Guclu, Alper

    2013-09-01

    The need to rapidly and cost-effectively evaluate the present condition of pavement infrastructure is a critical issue concerning the deterioration of ageing transportation infrastructure all around the world. Nondestructive testing (NDT) and evaluation methods are well-suited for characterising materials and determining structural integrity of pavement systems. The falling weight deflectometer (FWD) is a NDT equipment used to assess the structural condition of highway and airfield pavement systems and to determine the moduli of pavement layers. This involves static or dynamic inverse analysis (referred to as backcalculation) of FWD deflection profiles in the pavement surface under a simulated truck load. The main objective of this study was to employ biologically inspired computational systems to develop robust pavement layer moduli backcalculation algorithms that can tolerate noise or inaccuracies in the FWD deflection data collected in the field. Artificial neural systems, also known as artificial neural networks (ANNs), are valuable computational intelligence tools that are increasingly being used to solve resource-intensive complex engineering problems. Unlike the linear elastic layered theory commonly used in pavement layer backcalculation, non-linear unbound aggregate base and subgrade soil response models were used in an axisymmetric finite element structural analysis programme to generate synthetic database for training and testing the ANN models. In order to develop more robust networks that can tolerate the noisy or inaccurate pavement deflection patterns in the NDT data, several network architectures were trained with varying levels of noise in them. The trained ANN models were capable of rapidly predicting the pavement layer moduli and critical pavement responses (tensile strains at the bottom of the asphalt concrete layer, compressive strains on top of the subgrade layer and the deviator stresses on top of the subgrade layer), and also pavement

  17. Synthesis, spectroscopic analysis and electrochemical performance of modified β-nickel hydroxide electrode with CuO

    Directory of Open Access Journals (Sweden)

    B. Shruthi

    2017-03-01

    Full Text Available In the present work, a modified β-nickel hydroxide (β-Ni(OH2 electrode material with CuO has been prepared using a co-precipitation method. The structure and property of the modified β-Ni(OH2 with CuO were characterized by X-ray diffraction (XRD, Fourier Transform infra-red (FT-IR, Raman and thermal gravimetric-differential thermal analysis (TG-DTA techniques. The results of the FT-IR spectroscopy and TG-DTA indicate that the modified β-Ni(OH2 electrode materials contain intercalated water molecules and anions. A pasted–type electrode was prepared using nickel hydroxide powder as the main active material on a nickel sheet as a current collector. Cyclic voltammetry (CV and Electrochemical impedance spectroscopy (EIS studies were undertaken to assess the electrochemical behavior of pure β-Ni(OH2 and modified β-Ni(OH2 electrode with CuO in a 6 M KOH electrolyte. The addition of CuO into β-nickel hydroxide was found to enhance the reversibility of the electrode reaction and also increase the separation of the oxidation current peak of the active material from the oxygen evolution current. The modified nickel hydroxide with CuO was also found to exhibit a higher proton diffusion coefficient and a lower charge transfer resistance. These findings suggest that the modified β-Ni(OH2 with CuO possesses an enhanced electrochemical response and thus can be recognized as a promising candidate for battery electrode applications.

  18. Investigation of the corrosion resistance of Ti-13Nb-13Zr alloy by electrochemical techniques and surface analysis

    International Nuclear Information System (INIS)

    Assis, Sergio Luiz de

    2006-01-01

    In this work, the in vitro corrosion resistance of the Ti-13Nb-13Zr alloy, manufactured at a national laboratory, and used for orthopedic applications, has been investigated in solutions that simulate the body fluids. The electrolytes used were 0.9 % (mass) NaCl, Hanks' solution, a culture medium (MEM), and the two last electrolytes, without and with addition of hydrogen peroxide. The aim of peroxide addition was to simulate the conditions found when inflammatory reactions occur due to surgical procedures. The corrosion resistance of alloys commercially in use as biomaterials, Ti-6Al-7Nb and Ti-6Al-4V, as well as of the pure titanium (Ti-cp), was also studied for comparison with the Ti-13Nb-13Zr alloy. The corrosion resistance characterization was carried out by electrochemical and surface analysis techniques. The electrochemical tests used were: open circuit potential measurements as a function of tim; potentiodynamic polarization; and electrochemical impedance spectroscopy (EIE). The impedance experimental diagrams were interpreted using equivalent electric circuits that simulate an oxide film with a duplex structure composed of an internal and compact, barrier type layer, and an external porous layer. The results showed that the corrosion resistance is due mainly to the barrier type layer. The titanium alloys and the Ti-cp showed high corrosion resistance in all electrolytes used. The oxides formed on the Ti-13Nb-13Zr, either naturally or during immersion in MEM ar Hank's solution was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (MEV). The results showed that the presence of hydrogen peroxide in MEM promotes the growth of the porous layer and incorporation of mineral ions, besides favouring hydroxyapatite formation. The cytotoxicity of the Ti-13Nb-13Zr alloy was also evaluated and it was shown to be non-toxic. (author)

  19. Conformational analysis of large and highly disulfide-stabilized proteins by integrating online electrochemical reduction into an optimized H/D exchange mass spectrometry workflow

    DEFF Research Database (Denmark)

    Trabjerg, Esben; Jakobsen, Rasmus Uffe; Mysling, Simon

    2015-01-01

    Analysis of disulfide-bonded proteins by HDX-MS requires effective and rapid reduction of disulfide bonds before enzymatic digestion in order to increase sequence coverage. In a conventional HDX-MS workflow, disulfide bonds are reduced chemically by addition of a reducing agent to the quench......-antibody, respectively. The presented results demonstrate the successful electrochemical reduction during HDX-MS analysis of both a small exceptional tightly disulfide-bonded protein (NGF) as well as the largest protein attempted to date (IgG1-antibody). We envision that online electrochemical reduction...... the electrochemical reduction efficiency during HDX-MS analysis of two particularly challenging disulfide stabilized proteins: a therapeutic IgG1-antibody and Nerve Growth Factor-β (NGF). Several different parameters (flow rate, applied square wave potential as well as the type of labeling- and quench buffer) were...

  20. Noise resistance applied to the study paints

    International Nuclear Information System (INIS)

    Lanchas Garcia-Zarco, S.; Alfosin Perez, V.; Suarez Garcia, A.; Urrejola Madrinan, S.; Sanchez Bermudez, A.

    2015-01-01

    Electrochemical noise is one of the methods of analysis used to interpret the phenomenon of corrosion. It has a number of advantages over other methodology types including its simplicity, its low cost and the fact that it does not disturb the system. This methodology appears to be effective together with other techniques in metal-electrolyte systems. In this case the technique is applied on its own on commercial anti-corrosion paints for which no information is available from other techniques. The main result of this study reveals the effectiveness of the noise resistance parameter, which had already been tested in the lab, when it is used to explain how the paint system behaves in industry. (Author)

  1. A combined aeroelastic-aeroacoustic model for wind turbine noise: Verification and analysis of field measurements

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Fischer, Andreas

    2017-01-01

    In this paper, semi-empirical engineering models for the three main wind turbine aerodynamic noise sources, namely, turbulent inflow, trailing edge and stall noise, are introduced. They are implemented into the in-house aeroelastic code HAWC2 commonly used for wind turbine load calculations...... and design. The results of the combined aeroelastic and aeroacoustic model are compared with field noise measurements of a 500kW wind turbine. Model and experimental data are in fairly good agreement in terms of noise levels and directivity. The combined model allows separating the various noise sources...... and highlights a number of mechanisms that are difficult to differentiate when only the overall noise from a wind turbine is measured....

  2. Analysis of Sampling Methodologies for Noise Pollution Assessment and the Impact on the Population

    Directory of Open Access Journals (Sweden)

    Guillermo Rey Gozalo

    2016-05-01

    Full Text Available Today, noise pollution is an increasing environmental stressor. Noise maps are recognised as the main tool for assessing and managing environmental noise, but their accuracy largely depends on the sampling method used. The sampling methods most commonly used by different researchers (grid, legislative road types and categorisation methods were analysed and compared using the city of Talca (Chile as a test case. The results show that the stratification of sound values in road categories has a significantly lower prediction error and a higher capacity for discrimination and prediction than in the legislative road types used by the Ministry of Transport and Telecommunications in Chile. Also, the use of one or another method implies significant differences in the assessment of population exposure to noise pollution. Thus, the selection of a suitable method for performing noise maps through measurements is essential to achieve an accurate assessment of the impact of noise pollution on the population.

  3. Analysis of Sampling Methodologies for Noise Pollution Assessment and the Impact on the Population.

    Science.gov (United States)

    Rey Gozalo, Guillermo; Barrigón Morillas, Juan Miguel

    2016-05-11

    Today, noise pollution is an increasing environmental stressor. Noise maps are recognised as the main tool for assessing and managing environmental noise, but their accuracy largely depends on the sampling method used. The sampling methods most commonly used by different researchers (grid, legislative road types and categorisation methods) were analysed and compared using the city of Talca (Chile) as a test case. The results show that the stratification of sound values in road categories has a significantly lower prediction error and a higher capacity for discrimination and prediction than in the legislative road types used by the Ministry of Transport and Telecommunications in Chile. Also, the use of one or another method implies significant differences in the assessment of population exposure to noise pollution. Thus, the selection of a suitable method for performing noise maps through measurements is essential to achieve an accurate assessment of the impact of noise pollution on the population.

  4. Monitoring the mechanical vibration of in-core detector tubes and fuel channels via ICFD noise analysis

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Czuppon, G.J.; Kapoor, K.K.

    2000-01-01

    Vibrations of core internals are regularly monitored in the CANDU nuclear generating stations of Ontario Power Generation (OPG) via the noise analysis of in-core flux detectors (ICFDs). Voltage signals of standard station instrumentation are recorded by portable multi-channel high-speed high-resolution data acquisition systems, then statistical parameters are derived from the multi-channel time series measurements. Reactor noise analysis is a non-intrusive statistical technique regularly used in system surveillance, diagnostics and in actual operational I and C problems. It utilizes the dynamic information carried by the small fluctuations (noise) of station signals measured around their mean values during steady-state operation. The present paper discusses specific results related to the flow-induced mechanical vibrations of detector tubes and fuel channels. (author)

  5. Noise analysis method for monitoring the moderator temperature coefficient of pressurized water reactors: Neural network calibration

    International Nuclear Information System (INIS)

    Thomas, J.R. Jr.; Adams, J.T.

    1994-01-01

    A neural network was trained with data for the frequency response function between in-core neutron noise and core-exit thermocouple noise in a pressurized water reactor, with the moderator temperature coefficient (MTC) as target. The trained network was subsequently used to predict the MTC at other points in the same fuel cycle. Results support use of the method for operating pressurized water reactors provided noise data can be accumulated for several fuel cycles to provide a training base

  6. Assessment, analysis and appraisal of road traffic noise pollution in Rourkela city, India.

    Science.gov (United States)

    Goswami, Shreerup; Swain, Bijay Kumar; Panda, Santosh Kumar

    2013-09-01

    The problem of road traffic noise pollution has become a concern for both the public and the policy makers. Noise level was assessed in 12 different squares of Rourkela city during different specified times (7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m., 7-10 p.m., 10 p.m.-12 midnight and 4-6 a.m.). Noise descriptors such as L,eq, traffic noise index, noise pollution level, noise climate, Lday, Levening, Lnight and Lden were assessed to reveal the extent of noise pollution due to heavy traffic in this city. The equivalent noise levels of all the 12 squares were found to be much beyond the permissible limit (70dB during day time and 55dB during night time). Appallingly, even the minimum L eq and NPL values were more than 82 dB and 96 dB during day time and 69 dB and 91 dB during night time respectively. Lden values of investigated squares ranged from 83.4 to 86.1 dB and were even more than the day time permissible limit of traffic noise. The prediction model was used in the present study to predict noise pollution level instead of Leq. Comparison of predicted with that of the actual measured data demonstrated that the model used for the prediction has the ability to calibrate the multicomponent traffic noise and yield reliable results close to that by direct measurement. Lastly, it is inferred that the dimension of the traffic generated noise pollution in Rourkela is critical.

  7. Analysis of power tiller noise using diesel-biodiesel fuel blends

    OpenAIRE

    N Keramat Siavash; Gh Najafi; S. R Hassan Beigi Bidgoli; B Ghobadian

    2015-01-01

    Introduction: There are several sources of noise in an industrial and agriculture environment. Machines with rotating or reciprocating engines are sound-producing sources. Also, the audio signal can be analyzed to discover how well a machine operates. Diesel engines complex noise SPL and sound frequency content both strongly depend on fuel combustion, which produces the so-called combustion noise. Actually, the unpleasant sound signature of diesel engines is due to the harsh and irregular sel...

  8. Source localization analysis using seismic noise data acquired in exploration geophysics

    Science.gov (United States)

    Roux, P.; Corciulo, M.; Campillo, M.; Dubuq, D.

    2011-12-01

    Passive monitoring using seismic noise data shows a growing interest at exploration scale. Recent studies demonstrated source localization capability using seismic noise cross-correlation at observation scales ranging from hundreds of kilometers to meters. In the context of exploration geophysics, classical localization methods using travel-time picking fail when no evident first arrivals can be detected. Likewise, methods based on the intensity decrease as a function of distance to the source also fail when the noise intensity decay gets more complicated than the power-law expected from geometrical spreading. We propose here an automatic procedure developed in ocean acoustics that permits to iteratively locate the dominant and secondary noise sources. The Matched-Field Processing (MFP) technique is based on the spatial coherence of raw noise signals acquired on a dense array of receivers in order to produce high-resolution source localizations. Standard MFP algorithms permits to locate the dominant noise source by matching the seismic noise Cross-Spectral Density Matrix (CSDM) with the equivalent CSDM calculated from a model and a surrogate source position that scans each position of a 3D grid below the array of seismic sensors. However, at exploration scale, the background noise is mostly dominated by surface noise sources related to human activities (roads, industrial platforms,..), which localization is of no interest for the monitoring of the hydrocarbon reservoir. In other words, the dominant noise sources mask lower-amplitude noise sources associated to the extraction process (in the volume). Their location is therefore difficult through standard MFP technique. The Multi-Rate Adaptative Beamforming (MRABF) is a further improvement of the MFP technique that permits to locate low-amplitude secondary noise sources using a projector matrix calculated from the eigen-value decomposition of the CSDM matrix. The MRABF approach aims at cancelling the contributions of

  9. Sensitivity analysis of the noise-induced oscillatory multistability in Higgins model of glycolysis

    Science.gov (United States)

    Ryashko, Lev

    2018-03-01

    A phenomenon of the noise-induced oscillatory multistability in glycolysis is studied. As a basic deterministic skeleton, we consider the two-dimensional Higgins model. The noise-induced generation of mixed-mode stochastic oscillations is studied in various parametric zones. Probabilistic mechanisms of the stochastic excitability of equilibria and noise-induced splitting of randomly forced cycles are analysed by the stochastic sensitivity function technique. A parametric zone of supersensitive Canard-type cycles is localized and studied in detail. It is shown that the generation of mixed-mode stochastic oscillations is accompanied by the noise-induced transitions from order to chaos.

  10. Analysis of Beamformer Directed Single-Channel Noise Reduction System for Hearing Aid Applications

    DEFF Research Database (Denmark)

    Jensen, Jesper; Pedersen, Michael Syskind

    2015-01-01

    We study multi-microphone noise reduction systems consisting of a beamformer and a single-channel (SC) noise reduction stage. In particular, we present and analyse a maximum likelihood (ML) method for jointly estimating the target and noise power spectral densities (psd's) entering the SC filter....... We show that the estimators are minimum variance and unbiased, and provide closed-form expressions for their mean-square error (MSE). Furthermore, we show that the MSE of the noise psd estimator is particularly simple: it is independent of target signal characteristics, frequency, and microphone...

  11. A genome-wide analysis of promoter-mediated phenotypic noise in Escherichia coli.

    Directory of Open Access Journals (Sweden)

    Olin K Silander

    2012-01-01

    Full Text Available Gene expression is subject to random perturbations that lead to fluctuations in the rate of protein production. As a consequence, for any given protein, genetically identical organisms living in a constant environment will contain different amounts of that particular protein, resulting in different phenotypes. This phenomenon is known as "phenotypic noise." In bacterial systems, previous studies have shown that, for specific genes, both transcriptional and translational processes affect phenotypic noise. Here, we focus on how the promoter regions of genes affect noise and ask whether levels of promoter-mediated noise are correlated with genes' functional attributes, using data for over 60% of all promoters in Escherichia coli. We find that essential genes and genes with a high degree of evolutionary conservation have promoters that confer low levels of noise. We also find that the level of noise cannot be attributed to the evolutionary time that different genes have spent in the genome of E. coli. In contrast to previous results in eukaryotes, we find no association between promoter-mediated noise and gene expression plasticity. These results are consistent with the hypothesis that, in bacteria, natural selection can act to reduce gene expression noise and that some of this noise is controlled through the sequence of the promoter region alone.

  12. Electrochemical analysis of separators used in single-chamber, air-cathode microbial fuel cells

    KAUST Repository

    Wei, Bin

    2013-02-01

    Polarization, solution-separator, charge transfer, and diffusion resistances of clean and used separator electrode assemblies were examined in microbial fuel cells using current-voltage curves and electrochemical impedance spectroscopy (EIS). Current-voltage curves showed the total resistance was reduced at low cathode potentials. EIS results revealed that at a set cathode potential of 0.3 V diffusion resistance was predominant, and it substantially increased when adding separators. However, at a lower cathode potential of 0.1 V all resistances showed only slight differences with and without separators. Used separator electrode assemblies with biofilms had increased charge transfer and diffusion resistances (0.1 V) when one separator was used; however, charge transfer resistance increased, and diffusion resistance did not appreciably change with four separators. Adding a plastic mesh to compress the separators improved maximum power densities. These results show the importance of pressing separators against the cathode, and the adverse impacts of biofilm formation on electrochemical performance. © 2012 Elsevier Ltd. All Rights Reserved.

  13. Analysis of transport phenomena and electrochemical reactions in a micro PEM fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Sadiq Al-Baghdadi, Maher A.R. [Fuel Cell Research Center, International Energy and Environment Foundation, Najaf, P.O.Box 39 (Iraq)

    2013-07-01

    Micro-fuel cells are considered as promising electrochemical power sources in portable electronic devices. The presence of microelectromechanical system (MEMS) technology makes it possible to manufacture the miniaturized fuel cell systems. The majority of research on micro-scale fuel cells is aimed at micro-power applications. Performance of micro-fuel cells are closely related to many factors, such as designs and operating conditions. CFD modeling and simulation for heat and mass transport in micro PEM fuel cells are being used extensively in researches and industrial applications to gain better understanding of the fundamental processes and to optimize the micro fuel cell designs before building a prototype for engineering application. In this research, full three-dimensional, non-isothermal computational fluid dynamics model of a micro proton exchange membrane (PEM) fuel cell has been developed. This comprehensive model accounts for the major transport phenomena such as convective and diffusive heat and mass transfer, electrode kinetics, transport and phase-change mechanism of water, and potential fields in a micro PEM fuel cell. The model explains many interacting, complex electrochemical, and transport phenomena that cannot be studied experimentally. Three-dimensional results of the species profiles, temperature distribution, potential distribution, and local current density distribution are presented and analysed, with the focus on the physical insight and fundamental understanding.

  14. Electrochemical analysis of separators used in single-chamber, air-cathode microbial fuel cells

    KAUST Repository

    Wei, Bin; Tokash, Justin C.; Zhang, Fang; Kim, Younggy; Logan, Bruce E.

    2013-01-01

    Polarization, solution-separator, charge transfer, and diffusion resistances of clean and used separator electrode assemblies were examined in microbial fuel cells using current-voltage curves and electrochemical impedance spectroscopy (EIS). Current-voltage curves showed the total resistance was reduced at low cathode potentials. EIS results revealed that at a set cathode potential of 0.3 V diffusion resistance was predominant, and it substantially increased when adding separators. However, at a lower cathode potential of 0.1 V all resistances showed only slight differences with and without separators. Used separator electrode assemblies with biofilms had increased charge transfer and diffusion resistances (0.1 V) when one separator was used; however, charge transfer resistance increased, and diffusion resistance did not appreciably change with four separators. Adding a plastic mesh to compress the separators improved maximum power densities. These results show the importance of pressing separators against the cathode, and the adverse impacts of biofilm formation on electrochemical performance. © 2012 Elsevier Ltd. All Rights Reserved.

  15. Multiscale electrochemical analysis of the corrosion of titanium and nitinol for implant applications

    International Nuclear Information System (INIS)

    Izquierdo, J.; González-Marrero, M.B.; Bozorg, M.; Fernández-Pérez, B.M.; Vasconcelos, H.C.; Santana, J.J.; Souto, R.M.

    2016-01-01

    Highlights: • Direct screening of differences in the surface reactivity of the passive layers formed on pure titanium and nitinol. • Distinct effect of polarization on the passive layers. • Detection of nickel soluble species released from corrosion pits. - Abstract: Surface electrochemical activity of titanium and nitinol biomaterials in naturally aerated Ringer’s physiological solution was investigated using potentiodynamic polarization and scanning electrochemical microscopy (SECM) techniques. SECM was operated in feedback and redox competition modes as a function of potential applied to the substrate. The kinetics of the electron transfer rate on both materials was characterized by mathematical modelling of the Z-approach curves monitored under feedback conditions. The rate constant values greatly depended on the characteristics of the passive layers formed over the metals under potentiostatic control. A more insulating film was found on nitinol when biased at low polarizations, resulting in smaller tip current increments during tip approach to the investigated surface under positive feedback and competition operation modes. However, at higher anodic polarizations, nitinol passive layers experience breakdown, and therefore tip current values reflect the release of metal cations from the biomaterial surface.

  16. The Security Analysis of Two-Step Quantum Direct Communication Protocol in Collective-Rotation Noise Channel

    International Nuclear Information System (INIS)

    Li Jian; Sun Feng-Qi; Pan Ze-Shi; Nie Jin-Rui; Chen Yan-Hua; Yuan Kai-Guo

    2015-01-01

    To analyze the security of two-step quantum direct communication protocol (QDCP) by using Einstein–Podolsky–Rosen pair proposed by Deng et al. [Phys. Rev. A 68 (2003) 042317] in collective-rotation noise channel, an excellent model of noise analysis is proposed. In the security analysis, the method of the entropy theory is introduced, and is compared with QDCP, an error rate point Q 0 (M : (Q 0 , 1.0)) is given. In different noise levels, if Eve wants to obtain the same amount of information, the error rate Q is distinguishable. The larger the noise level ϵ is, the larger the error rate Q is. When the noise level ϵ is lower than 11%, the high error rate is 0.153 without eavesdropping. Lastly, the security of the proposed protocol is discussed. It turns out that the quantum channel will be safe when Q < 0.153. Similarly, if error rate Q > 0.153 = Q 0 , eavesdropping information I > 1, which means that there exist eavesdroppers in the quantum channel, and the quantum channel will not be safe anymore. (paper)

  17. An analysis of seismic background noise variation and evaluation of detection capability of Keskin Array (BRTR PS-43) in Turkey

    Science.gov (United States)

    Bakir, M. E.; Ozel, N. M.; Semin, K. U.

    2011-12-01

    Bogazici University, Kandilli Observatory and Earthquake Research Institute (KOERI) is currently operating the Keskin seismic array (BRTR-PS 43) located in town Keskin, providing real-time data to IDC. The instrumentaion of seismic array includes six short period borehole seismometers and one broadband borehole seismometer. The seismic background noise variation of Keskin array are studied in order to estimate the local and regional event detection capability in the frequency range from 1 Hz to 10 Hz. The Power density spectrum and also probability density function of Keskin array data were computed for seasonal and diurnal noise variations between 2008 and 2010. The computation will be extended to cover the period between 2005 and 2008. We attempt to determine the precise frequency characteristics of the background noise, which will help us to assess the station sensitivity. Minimum detectable magnitude versus distance for Keskin seismic array will be analyzed based on the seismic noise analysis. Detailed analysis results of seismic background noise and detection capability will be presented by this research.

  18. Statistical Analysis of Bending Rigidity Coefficient Determined Using Fluorescence-Based Flicker-Noise Spectroscopy.

    Science.gov (United States)

    Doskocz, Joanna; Drabik, Dominik; Chodaczek, Grzegorz; Przybyło, Magdalena; Langner, Marek

    2018-06-01

    Bending rigidity coefficient describes propensity of a lipid bilayer to deform. In order to measure the parameter experimentally using flickering noise spectroscopy, the microscopic imaging is required, which necessitates the application of giant unilamellar vesicles (GUV) lipid bilayer model. The major difficulty associated with the application of the model is the statistical character of GUV population with respect to their size and the homogeneity of lipid bilayer composition, if a mixture of lipids is used. In the paper, the bending rigidity coefficient was measured using the fluorescence-enhanced flicker-noise spectroscopy. In the paper, the bending rigidity coefficient was determined for large populations of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine vesicles. The quantity of obtained experimental data allows to perform statistical analysis aiming at the identification of the distribution, which is the most appropriate for the calculation of the value of the membrane bending rigidity coefficient. It has been demonstrated that the bending rigidity coefficient is characterized by an asymmetrical distribution, which is well approximated with the gamma distribution. Since there are no biophysical reasons for that we propose to use the difference between normal and gamma fits as a measure of the homogeneity of vesicle population. In addition, the effect of a fluorescent label and types of instrumental setups on determined values has been tested. Obtained results show that the value of the bending rigidity coefficient does not depend on the type of a fluorescent label nor on the type of microscope used.

  19. Studies on multivariate autoregressive analysis using synthesized reactor noise-like data for optimal modelling

    Energy Technology Data Exchange (ETDEWEB)

    Ciftcioglu, O.; Hoogenboom, J.E.; Dam, H. van

    1988-01-01

    Studies on the multivariate autoregressive (MAR) analysis are carried out for the choice of the parameters for modelling the data obtained from various sensors optimally. Accordingly, the roles of the parameters on the analysis results are identified and the related ambiguities are reduced. Experimental investigations are carried out by means of synthesized reactor noise-like data obtained from a digital simulator providing simulated stochastic signals of an operating nuclear reactor so that the simulator constitutes a favourable tool for the present studies aimed. As the system is well defined with its known structure, precise comparison of the MAR analysis results with the true values is performed. With the help of the information gained through the studies carried out, conditions to be taken care of for optimal signal processing in MAR modelling are determined. Although the parameters involved are related among themselves and they have to be given different values suitable for the particular application in hand, some criteria, namely memory-time and sample length-time play an essential role in AR modelling and they are found to be applicable to each individual case commonly, for the establishment of the optimality.

  20. Studies on multivariate autoregressive analysis using synthesized reactor noise-like data for optimal modelling

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1988-01-01

    Studies on the multivariate autoregressive (MAR) analysis are carried out for the choice of the parameters for modelling the data obtained from various sensors optimally. Accordingly, the roles of the parameters on the analysis results are identified and the related ambiguities are reduced. Experimental investigations are carried out by means of synthesized reactor noise-like data obtained from a digital simulator providing simulated stochastic signals of an operating nuclear reactor so that the simulator constitutes a favourable tool for the present studies aimed. As the system is well defined with its known structure, precise comparison of the MAR analysis results with the true values is performed. With the help of the information gained through the studies carried out, conditions to be taken care of for optimal signal processing in MAR modelling are determined. Although the parameters involved are related among themselves and they have to be given different values suitable for the particular application in hand, some criteria, namely memory-time and sample length-time play an essential role in AR modelling and they are found to be applicable to each individual case commonly, for the establishment of the optimality. (author)

  1. Histogram analysis of noise performance on fractional anisotropy brain MR image with different diffusion gradient numbers

    International Nuclear Information System (INIS)

    Chang, Yong Min; Kim, Yong Sun; Kang, Duk Sik; Lee, Young Joo; Sohn, Chul Ho; Woo, Seung Koo; Suh, Kyung Jin

    2005-01-01

    We wished to analyze, qualitatively and quantitatively, the noise performance of fractional anisotropy brain images along with the different diffusion gradient numbers by using the histogram method. Diffusion tensor images were acquired using a 3.0 T MR scanner from ten normal volunteers who had no neurological symptoms. The single-shot spin-echo EPI with a Stejskal-Tanner type diffusion gradient scheme was employed for the diffusion tensor measurement. With a b-valuee of 1000 s/mm 2 , the diffusion tensor images were obtained for 6, 11, 23, 35 and 47 diffusion gradient directions. FA images were generated for each DTI scheme. The histograms were then obtained at selected ROIs for the anatomical structures on the FA image. At the same ROI location, the mean FA value and the standard deviation of the mean FA value were calculated. The quality of the FA image was improved as the number of diffusion gradient directions increased by showing better contrast between the WM and GM. The histogram showed that the variance of FA values was reduced as the number of diffusion gradient directions increased. This histogram analysis was in good agreement with the result obtained using quantitative analysis. The image quality of the FA map was significantly improved as the number of diffusion gradient directions increased. The histogram analysis well demonstrated that the improvement in the FA images resulted from the reduction in the variance of the FA values included in the ROI

  2. Flow Injection Analysis with Electrochemical Detection for Rapid Identification of Platinum-Based Cytostatics and Platinum Chlorides in Water

    Directory of Open Access Journals (Sweden)

    Marketa Kominkova

    2014-02-01

    Full Text Available Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED. Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer and potential changes (1,000, 1,100 and 1,200 mV offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments.

  3. Electrochemical impedance spectroscopy analysis of a thin polymer film-based micro-direct methanol fuel cell

    Science.gov (United States)

    Schulz, Tobias; Weinmüller, Christian; Nabavi, Majid; Poulikakos, Dimos

    A single cell micro-direct methanol fuel cell (micro-DMFC) was investigated using electrochemical impedance spectroscopy. The electrodes consisted of thin, flexible polymer (SU8) film microchannel structures fabricated in-house using microfabrication techniques. AC impedance spectroscopy was used to separate contributions to the overall cell polarization from the anode, cathode and membrane. A clear distinction between the different electrochemical phenomena occurring in the micro-DMFC, especially the distinction between double layer charging and Faradaic reactions was shown. The effect of fuel flow rate, temperature, and anode flow channel structure on the impedance of the electrode reactions and membrane/electrode double layer charging were investigated. Analysis of impedance data revealed that the performance of the test cell was largely limited by the presence of intermediate carbon monoxide in the anode reaction. Higher temperatures increase cell performance by enabling intermediate CO to be oxidized at much higher rates. The results also revealed that serpentine anode flow microchannels show a lower tendency to intermediate CO coverage and a more stable cell behavior than parallel microchannels.

  4. An Elegant Analysis of White Spot Syndrome Virus Using a Graphene Oxide/Methylene Blue based Electrochemical Immunosensor Platform

    Science.gov (United States)

    Natarajan, Anusha; Devi, K. S. Shalini; Raja, Sudhakaran; Senthil Kumar, Annamalai

    2017-04-01

    White spot syndrome virus (WSSV) is a major devastating virus in aquaculture industry. A sensitive and selective diagnostic method for WSSV is a pressing need for the early detection and protection of the aquaculture farms. Herein, we first report, a simple electrochemical immunosensor based on methylene blue dye (MB) immobilized graphene oxide modified glassy carbon electrode (GCE/GO@MB) for selective, quick (35 ± 5 mins) and raw sample analysis of WSSV. The immunosensor was prepared by sequential modification of primary antibody, blocking agent (bovine serum album), antigen (as vp28 protein), secondary antibody coupled with horseradish peroxidase (Ab2-HRP) on the GCE/GO@MB. The modified electrode showed a well-defined redox peak at an equilibrium potential (E1/2), -0.4 V vs Ag/AgCl and mediated H2O2 reduction reaction without any false positive result and dissolved oxygen interferences in pH 7 phosphate buffer solution. Under an optimal condition, constructed calibration plot was linear in a range of 1.36 × 10-3 to 1.36 × 107 copies μL-1 of vp28. It is about four orders higher sensitive than that of the values observed with polymerase chain reaction (PCR) and western blot based WSSV detection techniques. Direct electrochemical immunosensing of WSSV in raw tissue samples were successfully demonstrated as a real sample system.

  5. Analysis of pumping tests: Significance of well diameter, partial penetration, and noise

    Science.gov (United States)

    Heidari, M.; Ghiassi, K.; Mehnert, E.

    1999-01-01

    The nonlinear least squares (NLS) method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating pumping wells, and with partially penetrating piezometers or observation wells. It was demonstrated that noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced an exact or acceptable set of parameters when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters, particularly that of specific storage, decreased with increases in the noise level in the observed drawdown data. With consideration of the well radii, the noiseless drawdown data from the pumping well in an unconfined aquifer produced good estimates of horizontal and vertical hydraulic conductivities and specific yield, but the estimated specific storage was unacceptable. When noisy data from the pumping well were used, an acceptable set of parameters was not obtained. Further experiments with noisy drawdown data in an unconfined aquifer revealed that when the well diameter was included in the analysis, hydraulic conductivity, specific yield and vertical hydraulic conductivity may be estimated rather effectively from piezometers located over a range of distances from the pumping well. Estimation of specific storage became less reliable for piezemeters located at distances greater than the initial saturated thickness of the aquifer. Application of the NLS to field pumping and recovery data from a confined aquifer showed that the estimated parameters from the two tests were in good agreement only when the well diameter was included in the analysis. Without consideration of well radii, the estimated values of hydraulic conductivity from the pumping and recovery tests were off by a factor of four.The nonlinear least squares method was applied to pumping and recovery aquifer test data in

  6. Analysis of log rate noise in Ontario's CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Hinds, H.W. [Dynamic Simulation and Analysis Corp., Deep River, Ontario (Canada); Banica, C.; Arguner, D. [Ontario Power Generation, Ajax, Ontario (Canada); Scharfenberg, R. [Bruce Power, Tiverton, Ontario (Canada)

    2007-07-01

    In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that the Log noise (source of Log Rate noise) was much larger for those ion chambers in the path of the moderator injection nozzles, compared to those which were not in the path. This 'extra' Log noise would then be either attenuated or amplified depending on the transfer function (time constants) of the Log Rate amplifier. It was also observed that most of the Log and Log Rate noise is independent of any other signal measured. Although all CANDU reactors in Ontario have Log and Log Rate noise, the Bruce A SDS1 system has the largest amount of Log Rate noise, because (a) its SDS1 (and RRS) ion chambers are at the top of the reactor in the path of the moderator injection nozzles, and (b) its SDS1 Log Rate amplifiers have the smallest time constants. (author)

  7. Robust spinal cord resting-state fMRI using independent component analysis-based nuisance regression noise reduction.

    Science.gov (United States)

    Hu, Yong; Jin, Richu; Li, Guangsheng; Luk, Keith Dk; Wu, Ed X

    2018-04-16

    Physiological noise reduction plays a critical role in spinal cord (SC) resting-state fMRI (rsfMRI). To reduce physiological noise and increase the robustness of SC rsfMRI by using an independent component analysis (ICA)-based nuisance regression (ICANR) method. Retrospective. Ten healthy subjects (female/male = 4/6, age = 27 ± 3 years, range 24-34 years). 3T/gradient-echo echo planar imaging (EPI). We used three alternative methods (no regression [Nil], conventional region of interest [ROI]-based noise reduction method without ICA [ROI-based], and correction of structured noise using spatial independent component analysis [CORSICA]) to compare with the performance of ICANR. Reduction of the influence of physiological noise on the SC and the reproducibility of rsfMRI analysis after noise reduction were examined. The correlation coefficient (CC) was calculated to assess the influence of physiological noise. Reproducibility was calculated by intraclass correlation (ICC). Results from different methods were compared by one-way analysis of variance (ANOVA) with post-hoc analysis. No significant difference in cerebrospinal fluid (CSF) pulsation influence or tissue motion influence were found (P = 0.223 in CSF, P = 0.2461 in tissue motion) in the ROI-based (CSF: 0.122 ± 0.020; tissue motion: 0.112 ± 0.015), and Nil (CSF: 0.134 ± 0.026; tissue motion: 0.124 ± 0.019). CORSICA showed a significantly stronger influence of CSF pulsation and tissue motion (CSF: 0.166 ± 0.045, P = 0.048; tissue motion: 0.160 ± 0.032, P = 0.048) than Nil. ICANR showed a significantly weaker influence of CSF pulsation and tissue motion (CSF: 0.076 ± 0.007, P = 0.0003; tissue motion: 0.081 ± 0.014, P = 0.0182) than Nil. The ICC values in the Nil, ROI-based, CORSICA, and ICANR were 0.669, 0.645, 0.561, and 0.766, respectively. ICANR more effectively reduced physiological noise from both tissue motion and CSF pulsation than three alternative methods. ICANR increases the robustness of SC rsf

  8. Integrating Electrochemical Detection with Centrifugal Microfluidics for Real-Time and Fully Automated Sample Testing

    DEFF Research Database (Denmark)

    Andreasen, Sune Zoëga; Kwasny, Dorota; Amato, Letizia

    2015-01-01

    Here we present a robust, stable and low-noise experimental set-up for performing electrochemical detection on a centrifugal microfluidic platform. By using a low-noise electronic component (electrical slip-ring) it is possible to achieve continuous, on-line monitoring of electrochemical experime......Here we present a robust, stable and low-noise experimental set-up for performing electrochemical detection on a centrifugal microfluidic platform. By using a low-noise electronic component (electrical slip-ring) it is possible to achieve continuous, on-line monitoring of electrochemical...

  9. The Combined Effects of Aircraft and Road Traffic Noise and Aircraft and Railway Noise on Noise Annoyance—An Analysis in the Context of the Joint Research Initiative NORAH

    Directory of Open Access Journals (Sweden)

    Jördis Wothge

    2017-08-01

    Full Text Available The Noise Related Annoyance Cognition and Health (NORAH research initiative is one of the most extensive studies on the physiological and psychological long-term effects of transportation noise in Europe. It includes research on the quality of life and annoyance as well as cardiovascular effects, sleep disturbance, breast cancer, blood pressure, depression and the cognitive development of children. Within the realm of the annoyance module of the study approximately 10,000 residents of the Rhine-Main district were surveyed on the combined effects of transportation noise. This included combined noise from aircraft and road traffic noise (N = 4905, or aircraft and railway noise (N = 4777. Results show that judgment of the total noise annoyance of participants was strongly determined by the sound source which was judged as more annoying (in this case aircraft noise. To a lesser extent, the average sound pressure level of the two present sources was also of relevance.

  10. A portable measurement system for subcriticality measurements by the Cf-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1987-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the 252 Cf-source-driven neutron noise analysis method. 8 refs

  11. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems.

    NARCIS (Netherlands)

    Bouwman, R.; Young, K.; Lazzari, B.; Ravaglia, V.; Broeders, M.J.M.; Engen, R. van

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does

  12. Elastomeric Structural Attachment Concepts for Aircraft Flap Noise Reduction - Challenges and Approaches to Hyperelastic Structural Modeling and Analysis

    Science.gov (United States)

    Sreekantamurthy, Thammaiah; Turner, Travis L.; Moore, James B.; Su, Ji

    2014-01-01

    Airframe noise is a significant part of the overall noise of transport aircraft during the approach and landing phases of flight. Airframe noise reduction is currently emphasized under the Environmentally Responsible Aviation (ERA) and Fixed Wing (FW) Project goals of NASA. A promising concept for trailing-edge-flap noise reduction is a flexible structural element or link that connects the side edges of the deployable flap to the adjacent main-wing structure. The proposed solution is distinguished by minimization of the span-wise extent of the structural link, thereby minimizing the aerodynamic load on the link structure at the expense of increased deformation requirement. Development of such a flexible structural link necessitated application of hyperelastic materials, atypical structural configurations and novel interface hardware. The resulting highly-deformable structural concept was termed the FLEXible Side Edge Link (FLEXSEL) concept. Prediction of atypical elastomeric deformation responses from detailed structural analysis was essential for evaluating feasible concepts that met the design constraints. The focus of this paper is to describe the many challenges encountered with hyperelastic finite element modeling and the nonlinear structural analysis of evolving FLEXSEL concepts. Detailed herein is the nonlinear analysis of FLEXSEL concepts that emerged during the project which include solid-section, foamcore, hollow, extended-span and pre-stressed concepts. Coupon-level analysis performed on elastomeric interface joints, which form a part of the FLEXSEL topology development, are also presented.

  13. First results of cross-correlation analysis of ambient seismic noise from the Hellenic Unified Seismic Network

    NARCIS (Netherlands)

    Panou, Areti; Paulssen, Hanneke; Hatzidimitriou, Panagiotis

    2015-01-01

    In this study we present phase velocity maps that were obtained from the cross-correlation analysis of ambient seismic noise recorded in the region of Greece.We used one year (2013) of ambient seismic data obtained from the vertical component of 64 broadband permanent seismological stations that are

  14. Analysis of in-band interference in noise-based frequency offset modulation

    NARCIS (Netherlands)

    Bilal, Ibrahim; Meijerink, Arjan; Bentum, Marinus Jan

    2014-01-01

    A noise-based frequency offset modulation (N-FOM) system is considered, employing a wideband noise carrier, transmit reference modulation and a self-correlation receiver. The performance of such a system in the presence of in-band interference is studied by modeling the interference as a Gaussian

  15. Is transverse feedback necessary for the SSC emittance preservation? (Vibration noise analysis and feedback parameters optimization)

    International Nuclear Information System (INIS)

    Parkhomchuk, V.V.; Shiltsev, V.D.

    1993-06-01

    The paper considers the Superconducting Super Collider (SSC) site ground motion measurements as well as data from accelerators worldwide about noises that worsen beam performance. Unacceptably fast emittance growth due to these noises is predicted for the SSC. A transverse feedback system was found to be the only satisfactory alternative to prevent emittance decay. Optimization of the primary feedback parameters was done

  16. Active3 noise reduction

    International Nuclear Information System (INIS)

    Holzfuss, J.

    1996-01-01

    Noise reduction is a problem being encountered in a variety of applications, such as environmental noise cancellation, signal recovery and separation. Passive noise reduction is done with the help of absorbers. Active noise reduction includes the transmission of phase inverted signals for the cancellation. This paper is about a threefold active approach to noise reduction. It includes the separation of a combined source, which consists of both a noise and a signal part. With the help of interaction with the source by scanning it and recording its response, modeling as a nonlinear dynamical system is achieved. The analysis includes phase space analysis and global radial basis functions as tools for the prediction used in a subsequent cancellation procedure. Examples are given which include noise reduction of speech. copyright 1996 American Institute of Physics

  17. Cost-Benefit Analysis of Rail-Noise Mitigation Programmes at European Level: Methodological Innovations from EURANO to STAIRRS

    OpenAIRE

    Aude Lenders; Nancy Da Silva; Walter Hecq; Baumgartner Thomas

    2001-01-01

    The STAIRRS project (2000-2002) is a follow-up of EURANO [1] and a Swiss study [2], in which the authors evaluated the efficiency of noise reduction measures in two European freight corridors. STAIRRS includes a cost-benefit analysis based on about 10,000 km of track modelled in seven countries. The benefits are defined in terms of the dB(A) experienced by those living in the rail corridors modelled. They are to be weighted by the number of persons benefiting each year from a noise reduction ...

  18. An analysis of roadway noise at residential estates in close proximity to expressways in Singapore

    Directory of Open Access Journals (Sweden)

    Indraneel Bhanap

    2013-01-01

    Full Text Available Singapore is a city-state of 5 million people. The entire urban population has expanded from 4.4 million to 5 million in a matter of 5 years. Because of the scarcity of land available, more major roads and expressways are being run close to residential developments, exposing the residents to expressway noise. Recognizing the problems of noise in a high-density urban society such as Singapore, the National Environmental Agency of Singapore (NEA has set prescribed noise limits for residential areas. The purpose of this paper is to analyze the noise level in one such development that is adjacent to an expressway, examine the effect of building height on noise and to compare the results with the NEA standards. The paper concludes with the implications of the results and a discussion on the solution to the problem.

  19. Verification test for on-line diagnosis algorithm based on noise analysis

    International Nuclear Information System (INIS)

    Tamaoki, T.; Naito, N.; Tsunoda, T.; Sato, M.; Kameda, A.

    1980-01-01

    An on-line diagnosis algorithm was developed and its verification test was performed using a minicomputer. This algorithm identifies the plant state by analyzing various system noise patterns, such as power spectral densities, coherence functions etc., in three procedure steps. Each obtained noise pattern is examined by using the distances from its reference patterns prepared for various plant states. Then, the plant state is identified by synthesizing each result with an evaluation weight. This weight is determined automatically from the reference noise patterns prior to on-line diagnosis. The test was performed with 50 MW (th) Steam Generator noise data recorded under various controller parameter values. The algorithm performance was evaluated based on a newly devised index. The results obtained with one kind of weight showed the algorithm efficiency under the proper selection of noise patterns. Results for another kind of weight showed the robustness of the algorithm to this selection. (orig.)

  20. Study on traffic noise level of Sylhet by multiple regression analysis associated with health hazards

    Directory of Open Access Journals (Sweden)

    J. B. Alam, M. Jobair Bin Alam, M. M. Rahman, A. K. Dikshit, S. K. Khan

    Full Text Available The study reports the level of traffic-induced noise pollution in Sylhet City. For this purpose noise levels have been measured at thirty-seven major locations of the city from 7 am to 11 pm during the working days. It was observed that at all the locations the level of noise remains far above the acceptable limit for all the time. The noise level on the main road near residential area, hospital area and educational area were above the recommended level (65dBA. It was found that the predictive equations are in 60-70% correlated with the measured noise level. The study suggests that vulnerable institutions like school and hospital should be located about 60m away from the roadside unless any special arrangement to alleviate sound is used.

  1. Noise analysis of gate electrode work function engineered recessed channel (GEWE-RC) MOSFET

    International Nuclear Information System (INIS)

    Agarwala, Ajita; Chaujar, Rishu

    2012-01-01

    This paper discusses the noise assessment, using ATLAS device simulation software, of a gate electrode work function engineered recessed channel (GEWE-RC) MOSFET involving an RC and GEWE design integrated onto a conventional MOSFET. Furthermore, the behaviour of GEWE-RC MOSFET is compared with that of a conventional MOSFET having the same device parameters. This paper thus optimizes and predicts the feasibility of a novel design, i.e., GEWE-RC MOSFET for high-performance applications where device and noise reduction is a major concern. The noise metrics taken into consideration are: minimum noise figure and optimum source impedance. The statistical tools auto correlation and cross correlation are also analysed owing to the random nature of noise.

  2. Photoacoustic signal and noise analysis for Si thin plate: signal correction in frequency domain.

    Science.gov (United States)

    Markushev, D D; Rabasović, M D; Todorović, D M; Galović, S; Bialkowski, S E

    2015-03-01

    Methods for photoacoustic signal measurement, rectification, and analysis for 85 μm thin Si samples in the 20-20 000 Hz modulation frequency range are presented. Methods for frequency-dependent amplitude and phase signal rectification in the presence of coherent and incoherent noise as well as distortion due to microphone characteristics are presented. Signal correction is accomplished using inverse system response functions deduced by comparing real to ideal signals for a sample with well-known bulk parameters and dimensions. The system response is a piece-wise construction, each component being due to a particular effect of the measurement system. Heat transfer and elastic effects are modeled using standard Rosencweig-Gersho and elastic-bending theories. Thermal diffusion, thermoelastic, and plasmaelastic signal components are calculated and compared to measurements. The differences between theory and experiment are used to detect and correct signal distortion and to determine detector and sound-card characteristics. Corrected signal analysis is found to faithfully reflect known sample parameters.

  3. An insight into the adsorption and electrochemical processes occurring during the analysis of copper and lead in wines, using an electrochemical quartz crystal nanobalance.

    Science.gov (United States)

    Yamasaki, Alzira; Oliveira, João A B P; Duarte, Armando C; Gomes, M Teresa S R

    2012-08-30

    Copper and lead in wine were quantified by anodic stripping voltammetry (ASV), performed onto the gold electrode of a piezoelectric quartz crystal. Both current or mass changes could be used as analytical signals, without a statistical difference in the results (α=0.05). However, the plot of mass vs. potential provided an in depth understanding of the electrochemical processes and allowed studying adsorption phenomena. Copper interaction with fructose is an example of a process which was not possible to ignore by observing the mass change on the gold electrode of the piezoelectric quartz crystal. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Microscopic Analysis and Electrochemical Behavior of Fe-Based Coating Produced by Laser Cladding

    Directory of Open Access Journals (Sweden)

    Jinlin Chen

    2017-10-01

    Full Text Available The effect of laser cladding on the surface microstructure and corrosion properties of coated/uncoated specimens were investigated. Fe-based alloy coating was produced on 35CrMo steel by laser cladding. The phase composition, microstructure, interface element distribution, microhardness and corrosion resistance of the cladding coating were measured. The results show that the cladding layer is mainly composed of α-Fe phases, the microstructure presents a gradient distribution, and a good metallurgical bond is formed at the boundary with the substrate. Microhardness profiles show that the average microhardness of the cladding coating is about 2.1 times higher than that of the uncoated specimen. In addition, the electrochemical results show that the coated specimen exhibits far better corrosion resistance than to the uncoated specimen.

  5. Parameter analysis on the ultrasonic TSV-filling process and electrochemical characters

    Science.gov (United States)

    Wang, Fuliang; Ren, Xinyu; Wang, Yan; Zeng, Peng; Zhou, Zhaohua; Xiao, Hongbin; Zhu, Wenhui

    2017-10-01

    As one of the key technologies in 3D packaging, through silicon via (TSV) interconnection technology has become a focus recently. In this paper, an electrodeposition method for TSV filling with the assistance of ultrasound and additives are introduced. Two important parameters i.e. current density and ultrasonic power are studied for TSV filling process and electrochemical properties. It is found that ultrasound can improve the quality of TSV-filling and change the TSV-filling mode. The experimental results also indicate that the filling rate enhances more significantly with decreasing current density under ultrasonic conditions than under silent conditions. In addition, according to the voltammetry curve, the increase of ultrasonic power can significantly increase the current density of cupric reduction, and decrease the thickness of diffusion layer. So that the reduction speed of copper ions is accelerated, resulting in a higher TSV-filling rate.

  6. Corrosion analysis of AlMg2 and AlMgSi using electrochemical method

    International Nuclear Information System (INIS)

    Dian A; Maman Kartaman; Rosika K; Yanlinastuti

    2014-01-01

    Corrosion test of cladding materials and structures of research reactor fuel, AlMgSi and AlMg2 have been performed in demineralized water of pH 2 and 6.7 using an electrochemical method. Corrosion phenomenon is affected by several factor such as composition and condition of solution. The purpose of this activity is to investigate the corrosion phenomena through the determination of the parameters of corrosion and polarization curve. The materials used are AlMg2 and AlMgSi alloy in circular dish shape with an area of 1 Cm"2. Preparation of the test sample is performed through several stages polishing, cleaning and drying procedures followed ASTM G3. The electrochemical method is done by measuring the open circuit potential (OCP), polarization resistance and potentiodynamic in demineralized water of pH 2 and pH 6.7 at temperature of 25°C. The results of the OCP is the corrosion potential (Ecorr) of AlMg2 and AlMgSi each of -906.1 mV and -619.8 mV at pH 2 and -868.6 and -756.7 mV at pH 6.7 mV. The results of measurements by polarization resistance technique showed that the corrosion rate of AlMg2 and AlMgSi in safe category (<2 mpy) at pH 6.7 and at pH 2 corrosion rate increased significantly, but still in the lightweight category (<20 mpy). Potentiodynamic curves showed that the passivation at pH 6.7 is very low while the passivation at pH 2 occurs within a relatively short range potential and followed events corroded. (author)

  7. Electrochemical analysis of the UV treated bactericidal Ti6Al4V surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Pacha-Olivenza, Miguel A. [Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) (Spain); Department of Applied Physics, Faculty of Science, University of Extremadura, Av. Elvas s/n, 06071 Badajoz (Spain); Gallardo-Moreno, Amparo M., E-mail: amparogm@unex.es [Department of Applied Physics, Faculty of Science, University of Extremadura, Av. Elvas s/n, 06071 Badajoz (Spain); Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) (Spain); Vadillo-Rodríguez, Virginia; González-Martín, M. Luisa [Department of Applied Physics, Faculty of Science, University of Extremadura, Av. Elvas s/n, 06071 Badajoz (Spain); Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) (Spain); Pérez-Giraldo, Ciro [Department of Microbiology, Faculty of Medicine, University of Extremadura, Av. Elvas s/n, 06071 Badajoz (Spain); Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) (Spain); Galván, Juan C. [National Centre for Metallurgical Research (CENIM-CSIC), Av. Gregorio del Amo 8, 28040-Madrid (Spain)

    2013-04-01

    This research investigates in detail the bactericidal effect exhibited by the surface of the biomaterial Ti6Al4V after being subjected to UV-C light. It has been recently hypothesized that small surface currents, occurring as a consequence of the electron–hole pair recombination taking place after the excitation process, are behind the bactericidal properties displayed by this UV-treated material. To corroborate this hypothesis we have used different electrochemical techniques, such as electrochemical impedance spectroscopy (EIS), potentiodynamic polarization plots and Mott–Schottky plots. EIS and Mott–Schottky plots have shown that UV-C treatment causes an initial increase on the surface electrical conduction of this material. In addition, EIS and polarization plots demonstrated that higher corrosion currents occur at the UV treated than at the non-irradiated samples. Despite this increase in the corrosion currents, EIS has also shown that such currents are not likely to affect the good stability of this material oxide film since the irradiated samples completely recovered the control values after being stored in dark conditions for a period not longer than 24 h. These results agree with the already-published in vitro transitory behavior of the bactericidal effect, which was shown to be present at initial times after the biomaterial implantation, a crucial moment to avoid a large number of biomaterial associated infections. Highlights: ► Bactericidal response of UV-treated Ti6Al4V is explained through electrochemistry. ► There is an increase in the superficial electrical conduction after UV-treatment. ► Higher corrosion currents for UV-treated against non-UV-treated samples are shown. ► EIS shows the recuperation on irradiated samples in agreement with microbial tests.

  8. Theoretical Analysis of Proton Relays in Electrochemical Proton-Coupled Electron Transfer

    International Nuclear Information System (INIS)

    Auer, Benjamin; Fernandez, Laura; Hammes-Schiffer, Sharon

    2011-01-01

    The coupling of long-range electron transfer to proton transport over multiple sites plays a vital role in many biological and chemical processes. Recently a molecule with a hydrogen-bond relay inserted between the proton donor and acceptor sites in a proton-coupled electron transfer (PCET) system was studied electrochemically. The standard rate constants and kinetic isotope effects (KIEs) were measured experimentally for this system and a related single proton transfer system. In the present paper, these systems are studied theoretically using vibronically nonadiabatic rate constant expressions for electrochemical PCET. Application of this approach to proton relays requires the calculation of multidimensional proton vibrational wavefunctions and incorporation of multiple proton donor-acceptor motions. The calculated KIEs and relative standard rate constants for the single and double proton transfer systems are in agreement with the experimental data. The calculations indicate that the standard rate constant is lower for the double proton transfer system because of the smaller overlap integral between the ground state reduced and oxidized proton vibrational wavefunctions for this system, resulting in greater contributions from excited electron-proton vibronic states with higher free energy barriers. The decrease in proton donor-acceptor distances due to thermal fluctuations and the contributions from excited electron-proton vibronic states play important roles in proton relay systems. The theory suggests that the PCET rate constant may be increased by decreasing the equilibrium proton donor-acceptor distances or modifying the thermal motions of the molecule to facilitate the concurrent decrease of these distances. The submission of this journal article in ERIA is a requirement of the EFRC subcontract with Pennsylvania State University collaborators to get publications to OSTI.

  9. Electrochemical analysis of the UV treated bactericidal Ti6Al4V surfaces

    International Nuclear Information System (INIS)

    Pacha-Olivenza, Miguel A.; Gallardo-Moreno, Amparo M.; Vadillo-Rodríguez, Virginia; González-Martín, M. Luisa; Pérez-Giraldo, Ciro; Galván, Juan C.

    2013-01-01

    This research investigates in detail the bactericidal effect exhibited by the surface of the biomaterial Ti6Al4V after being subjected to UV-C light. It has been recently hypothesized that small surface currents, occurring as a consequence of the electron–hole pair recombination taking place after the excitation process, are behind the bactericidal properties displayed by this UV-treated material. To corroborate this hypothesis we have used different electrochemical techniques, such as electrochemical impedance spectroscopy (EIS), potentiodynamic polarization plots and Mott–Schottky plots. EIS and Mott–Schottky plots have shown that UV-C treatment causes an initial increase on the surface electrical conduction of this material. In addition, EIS and polarization plots demonstrated that higher corrosion currents occur at the UV treated than at the non-irradiated samples. Despite this increase in the corrosion currents, EIS has also shown that such currents are not likely to affect the good stability of this material oxide film since the irradiated samples completely recovered the control values after being stored in dark conditions for a period not longer than 24 h. These results agree with the already-published in vitro transitory behavior of the bactericidal effect, which was shown to be present at initial times after the biomaterial implantation, a crucial moment to avoid a large number of biomaterial associated infections. Highlights: ► Bactericidal response of UV-treated Ti6Al4V is explained through electrochemistry. ► There is an increase in the superficial electrical conduction after UV-treatment. ► Higher corrosion currents for UV-treated against non-UV-treated samples are shown. ► EIS shows the recuperation on irradiated samples in agreement with microbial tests

  10. Speckle noise reduction technique for Lidar echo signal based on self-adaptive pulse-matching independent component analysis

    Science.gov (United States)

    Xu, Fan; Wang, Jiaxing; Zhu, Daiyin; Tu, Qi

    2018-04-01

    Speckle noise has always been a particularly tricky problem in improving the ranging capability and accuracy of Lidar system especially in harsh environment. Currently, effective speckle de-noising techniques are extremely scarce and should be further developed. In this study, a speckle noise reduction technique has been proposed based on independent component analysis (ICA). Since normally few changes happen in the shape of laser pulse itself, the authors employed the laser source as a reference pulse and executed the ICA decomposition to find the optimal matching position. In order to achieve the self-adaptability of algorithm, local Mean Square Error (MSE) has been defined as an appropriate criterion for investigating the iteration results. The obtained experimental results demonstrated that the self-adaptive pulse-matching ICA (PM-ICA) method could effectively decrease the speckle noise and recover the useful Lidar echo signal component with high quality. Especially, the proposed method achieves 4 dB more improvement of signal-to-noise ratio (SNR) than a traditional homomorphic wavelet method.

  11. Neural Segregation of Concurrent Speech: Effects of Background Noise and Reverberation on Auditory Scene Analysis in the Ventral Cochlear Nucleus.

    Science.gov (United States)

    Sayles, Mark; Stasiak, Arkadiusz; Winter, Ian M

    2016-01-01

    Concurrent complex sounds (e.g., two voices speaking at once) are perceptually disentangled into separate "auditory objects". This neural processing often occurs in the presence of acoustic-signal distortions from noise and reverberation (e.g., in a busy restaurant). A difference in periodicity between sounds is a strong segregation cue under quiet, anechoic conditions. However, noise and reverberation exert differential effects on speech intelligibility under "cocktail-party" listening conditions. Previous neurophysiological studies have concentrated on understanding auditory scene analysis under ideal listening conditions. Here, we examine the effects of noise and reverberation on periodicity-based neural segregation of concurrent vowels /a/ and /i/, in the responses of single units in the guinea-pig ventral cochlear nucleus (VCN): the first processing station of the auditory brain stem. In line with human psychoacoustic data, we find reverberation significantly impairs segregation when vowels have an intonated pitch contour, but not when they are spoken on a monotone. In contrast, noise impairs segregation independent of intonation pattern. These results are informative for models of speech processing under ecologically valid listening conditions, where noise and reverberation abound.

  12. Implementation of New Reactivity Measurement System and New Reactor Noise Analysis Equipment in a VVER-440 Nuclear Power Plant

    Science.gov (United States)

    Vegh, János; Kiss, Sándor; Lipcsei, Sándor; Horvath, Csaba; Pos, István; Kiss, Gábor

    2010-10-01

    The paper deals with two recently developed, high-precision nuclear measurement systems installed at the VVER-440 units of the Hungarian Paks NPP. Both developments were motivated by the reactor power increase to 108%, and by the planned plant service time extension. The first part describes the RMR start-up reactivity measurement system with advanced services. High-precision picoampere meters were installed at each reactor unit and measured ionization chamber current signals are handled by a portable computer providing data acquisition and online reactivity calculation service. Detailed offline evaluation and analysis of reactor start-up measurements can be performed on the portable unit, too. The second part of the paper describes a new reactor noise diagnostics system using state-of-the-art data acquisition hardware and signal processing methods. Details of the new reactor noise measurement evaluation software are also outlined. Noise diagnostics at Paks NPP is a standard tool for core anomaly detection and for long-term noise trend monitoring. Regular application of these systems is illustrated by real plant data, e.g., results of standard reactivity measurements during a reactor startup session are given. Noise applications are also illustrated by real plant measurements; results of core anomaly detection are presented.

  13. Landing Gear Noise Prediction and Analysis for Tube-and-Wing and Hybrid-Wing-Body Aircraft

    Science.gov (United States)

    Guo, Yueping; Burley, Casey L.; Thomas, Russell H.

    2016-01-01

    Improvements and extensions to landing gear noise prediction methods are developed. New features include installation effects such as reflection from the aircraft, gear truck angle effect, local flow calculation at the landing gear locations, gear size effect, and directivity for various gear designs. These new features have not only significantly improved the accuracy and robustness of the prediction tools, but also have enabled applications to unconventional aircraft designs and installations. Systematic validations of the improved prediction capability are then presented, including parametric validations in functional trends as well as validations in absolute amplitudes, covering a wide variety of landing gear designs, sizes, and testing conditions. The new method is then applied to selected concept aircraft configurations in the portfolio of the NASA Environmentally Responsible Aviation Project envisioned for the timeframe of 2025. The landing gear noise levels are on the order of 2 to 4 dB higher than previously reported predictions due to increased fidelity in accounting for installation effects and gear design details. With the new method, it is now possible to reveal and assess the unique noise characteristics of landing gear systems for each type of aircraft. To address the inevitable uncertainties in predictions of landing gear noise models for future aircraft, an uncertainty analysis is given, using the method of Monte Carlo simulation. The standard deviation of the uncertainty in predicting the absolute level of landing gear noise is quantified and determined to be 1.4 EPNL dB.

  14. Application of noise analysis technique for monitoring the moderator temperature coefficient of reactivity in pressurized water reactors

    International Nuclear Information System (INIS)

    Shieh, D.J.; Upadhyaya, B.R.; Sweeney, F.J.

    1987-01-01

    A new technique, based on the noise analysis of neutron detector and core-exit coolant temperature signals, is developed for monitoring the moderator temperature coefficient of reactivity in pressurized water reactors (PWRs). A detailed multinodal model is developed and evaluated for the reactor core subsystem of the loss-of-fluid test (LOFT) reactor. This model is used to study the effect of changing the sign of the moderator temperature coefficient of reactivity on the low-frequency phase angle relationship between the neutron detector and the core-exit temperature noise signals. Results show that the phase angle near zero frequency approaches - 180 deg for negative coefficients and 0 deg for positive coefficients when the perturbation source for the noise signals is core coolant flow, inlet coolant temperature, or random heat transfer

  15. Response analysis of a class of quasi-linear systems with fractional derivative excited by Poisson white noise

    Science.gov (United States)

    Yang, Yongge; Xu, Wei; Yang, Guidong; Jia, Wantao

    2016-08-01

    The Poisson white noise, as a typical non-Gaussian excitation, has attracted much attention recently. However, little work was referred to the study of stochastic systems with fractional derivative under Poisson white noise excitation. This paper investigates the stationary response of a class of quasi-linear systems with fractional derivative excited by Poisson white noise. The equivalent stochastic system of the original stochastic system is obtained. Then, approximate stationary solutions are obtained with the help of the perturbation method. Finally, two typical examples are discussed in detail to demonstrate the effectiveness of the proposed method. The analysis also shows that the fractional order and the fractional coefficient significantly affect the responses of the stochastic systems with fractional derivative.

  16. Response analysis of a class of quasi-linear systems with fractional derivative excited by Poisson white noise

    International Nuclear Information System (INIS)

    Yang, Yongge; Xu, Wei; Yang, Guidong; Jia, Wantao

    2016-01-01

    The Poisson white noise, as a typical non-Gaussian excitation, has attracted much attention recently. However, little work was referred to the study of stochastic systems with fractional derivative under Poisson white noise excitation. This paper investigates the stationary response of a class of quasi-linear systems with fractional derivative excited by Poisson white noise. The equivalent stochastic system of the original stochastic system is obtained. Then, approximate stationary solutions are obtained with the help of the perturbation method. Finally, two typical examples are discussed in detail to demonstrate the effectiveness of the proposed method. The analysis also shows that the fractional order and the fractional coefficient significantly affect the responses of the stochastic systems with fractional derivative.

  17. Response analysis of a class of quasi-linear systems with fractional derivative excited by Poisson white noise

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yongge; Xu, Wei, E-mail: weixu@nwpu.edu.cn; Yang, Guidong; Jia, Wantao [Department of Applied Mathematics, Northwestern Polytechnical University, Xi' an 710072 (China)

    2016-08-15

    The Poisson white noise, as a typical non-Gaussian excitation, has attracted much attention recently. However, little work was referred to the study of stochastic systems with fractional derivative under Poisson white noise excitation. This paper investigates the stationary response of a class of quasi-linear systems with fractional derivative excited by Poisson white noise. The equivalent stochastic system of the original stochastic system is obtained. Then, approximate stationary solutions are obtained with the help of the perturbation method. Finally, two typical examples are discussed in detail to demonstrate the effectiveness of the proposed method. The analysis also shows that the fractional order and the fractional coefficient significantly affect the responses of the stochastic systems with fractional derivative.

  18. Development of Self-Powered Wireless-Ready High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring for Boiler Tubes in Next Generation Coal-based Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xingbo [West Virginia Univ., Morgantown, WV (United States)

    2015-06-30

    The key innovation of this project is the synergy of the high temperature sensor technology based on the science of electrochemical measurement and state-of-the-art wireless communication technology. A novel self-powered wireless high temperature electrochemical sensor system has been developed for coal-fired boilers used for power generation. An initial prototype of the in-situ sensor demonstrated the capability of the wireless communication system in the laboratory and in a pilot plant (Industrial USC Boiler Setting) environment to acquire electrochemical potential and current signals during the corrosion process. Uniform and localized under-coal ash deposit corrosion behavior of Inconel 740 superalloy has been studied at different simulated coal ash hot corrosion environments using the developed sensor. Two typical potential noise patterns were found to correlate with the oxidation and sulfidation stages in the hot coal ash corrosion process. Two characteristic current noise patterns indicate the extent of the corrosion. There was a good correlation between the responses of electrochemical test data and the results from corroded surface analysis. Wireless electrochemical potential and current noise signals from a simulated coal ash hot corrosion process were concurrently transmitted and recorded. The results from the performance evaluation of the sensor confirm a high accuracy in the thermodynamic and kinetic response represented by the electrochemical noise and impedance test data.

  19. Bayesian analysis of radial velocity data of GJ667C with correlated noise: evidence for only two planets

    Science.gov (United States)

    Feroz, F.; Hobson, M. P.

    2014-02-01

    GJ667C is the least massive component of a triple star system which lies at a distance of about 6.8 pc (22.1 light-year) from the Earth. GJ667C has received much attention recently due to the claims that it hosts up to seven planets including three super-Earths inside the habitable zone. We present a Bayesian technique for the analysis of radial velocity (RV) data sets in the presence of correlated noise component (`red noise'), with unknown parameters. We also introduce hyper-parameters in our model in order to deal statistically with under- or overestimated error bars on measured RVs as well as inconsistencies between different data sets. By applying this method to the RV data set of GJ667C, we show that this data set contains a significant correlated (red) noise component with correlation time-scale for HARPS data of the order of 9 d. Our analysis shows that the data only provide strong evidence for the presence of two planets: GJ667Cb and c with periods 7.19 and 28.13 d, respectively, with some hints towards the presence of a third signal with period 91 d. The planetary nature of this third signal is not clear and additional RV observations are required for its confirmation. Previous claims of the detection of additional planets in this system are due the erroneous assumption of white noise. Using the standard white noise assumption, our method leads to the detection of up to five signals in this system. We also find that with the red noise model, the measurement uncertainties from HARPS for this system are underestimated at the level of ˜50 per cent.

  20. Analysis of the noise of the jet pumps of the Unit 2 of the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Castillo D, R.; Ortiz V, J.; Ruiz E, J.A.; Calleros M, G.

    2004-01-01

    The use of the analysis of noise for the detection of badly functioning of the components of a BWR it is a powerful tool in the determination of abnormal conditions of operation, during the life of a nuclear plant of power. From the eighties, some nuclear reactors have presented problems related with the jet pumps and the knots of the recirculation. The Regulatory Commission of the United States, in the I E bulletin 80-07, recommended to carry out a periodic supervision of the pressure drop of the jet pumps, to prevent structural failures. In this work, methods of analysis of noise are used for the detection of abnormal conditions of operation of the jet pumps of a BWR. Signals are analysed to low and high frequency of pressure drop with the NOISE software that is in development. The obtained results show the behavior of the jet pumps of jet 6 and 11 before and after a partial blockade in their throats where the pump 6 return to their condition of previous operation and the pump 11 present a new fall of pressure, inside the limit them permissible of operation. The methodology of the analysis of noise demonstrated to be an useful tool for the badly functioning detection, and you could apply to create a database to supervise the dynamic behavior of the jet pumps of an BWR. (Author)

  1. Analysis and Extension of the Percentile Method, Estimating a Noise Curve from a Single Image

    Directory of Open Access Journals (Sweden)

    Miguel Colom

    2013-12-01

    Full Text Available Given a white Gaussian noise signal on a sampling grid, its variance can be estimated from a small block sample. However, in natural images we observe the combination of the geometry of the scene being photographed and the added noise. In this case, estimating directly the standard deviation of the noise from block samples is not reliable since the measured standard deviation is not explained just by the noise but also by the geometry of the image. The Percentile method tries to estimate the standard deviation of the noise from blocks of a high-passed version of the image and a small p-percentile of these standard deviations. The idea behind is that edges and textures in a block of the image increase the observed standard deviation but they never make it decrease. Therefore, a small percentile (0.5%, for example in the list of standard deviations of the blocks is less likely to be affected by the edges and textures than a higher percentile (50%, for example. The 0.5%-percentile is empirically proven to be adequate for most natural, medical and microscopy images. The Percentile method is adapted to signal-dependent noise, which is realistic with the Poisson noise model obtained by a CCD device in a digital camera.

  2. Signal and noise analysis in TRION-Time-Resolved Integrative Optical Fast Neutron detector

    International Nuclear Information System (INIS)

    Vartsky, D; Feldman, G; Mor, I; Goldberg, M B; Bar, D; Dangendorf, V

    2009-01-01

    TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector. In contrast to event-counting detectors where the signal-to-noise ratio is dependent only on the number of detected events (quantum noise), in an energy-integrating detector additional factors, such as the fluctuations in imparted energy, number of photoelectrons, system gain and other factors will contribute to the noise. The excess noise factor (over the quantum noise) due to these processes was 4.3, 2.7, 2.1, 1.9 and 1.9 for incident neutron energies of 2, 4, 7.5, 10 and 14 MeV, respectively. It is shown that, even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted proton energy and the resulting scintillation light distributions.

  3. Simulation of reactor noise analysis measurement for light-water critical assembly TCA using MCNP-DSP

    International Nuclear Information System (INIS)

    Yamamoto, Toshihiro; Sakurai, Kiyoshi; Tonoike, Kotaro; Miyoshi, Yoshinori

    2001-01-01

    Reactor noise analysis methods using Monte Carlo technique have been proposed and developed in the field of nuclear criticality safety. The Monte Carlo simulation for noise analysis can be made by simulating physical phenomena in the course of neutron transport in a nuclear fuel as practically as possible. MCNP-DSP was developed by T. Valentine of ORNL for this purpose and it is a modified version of MCNP-4A. The authors applied this code to frequency analysis measurements performed in light-water critical assembly TCA. Prompt neutron generation times for critical and subcritical cores were measured by doing the frequency analysis of detector signals. The Monte Carlo simulations for these experiments were carried out using MCNP-DSP, and prompt neutron generation times were calculated. (author)

  4. Allan Deviation Plot as a Tool for Quartz-Enhanced Photoacoustic Sensors Noise Analysis.

    Science.gov (United States)

    Giglio, Marilena; Patimisco, Pietro; Sampaolo, Angelo; Scamarcio, Gaetano; Tittel, Frank K; Spagnolo, Vincenzo

    2016-04-01

    We report here on the use of the Allan deviation plot to analyze the long-term stability of a quartz-enhanced photoacoustic (QEPAS) gas sensor. The Allan plot provides information about the optimum averaging time for the QEPAS signal and allows the prediction of its ultimate detection limit. The Allan deviation can also be used to determine the main sources of noise coming from the individual components of the sensor. Quartz tuning fork thermal noise dominates for integration times up to 275 s, whereas at longer averaging times, the main contribution to the sensor noise originates from laser power instabilities.

  5. Measurement and analysis of noise power spectrum of computerized tomography in images

    International Nuclear Information System (INIS)

    Castro Tejero, P.; Garayoa Roca, J.

    2013-01-01

    This paper examines the implementation of the spectrum of powers of the noise, NPS, as metric to characterize the noise, both in magnitude and in texture, for CT scans. The NPS found show that you for convolution filters that assume a greater softening in the reconstructed image, spectrum is concentrated in the low frequencies, while for filters sharp, the spectrum extends to high frequencies. In the analyzed cases, there is a low frequency component, largely due to the structure-borne noise, which can be a potential negative effect on the detectability of injuries. (Author)

  6. Prediction of noise in ships by the application of “statistical energy analysis.”

    DEFF Research Database (Denmark)

    Jensen, John Ødegaard

    1979-01-01

    If it will be possible effectively to reduce the noise level in the accomodation on board ships, by introducing appropriate noise abatement measures already at an early design stage, it is quite essential that sufficiently accurate prediction methods are available for the naval architects...... or for a special noise abatement measure, e.g., increased structural damping. The paper discusses whether it might be possible to derive an alternative calculation model based on the “statistical energy analysis” approach (SEA). By considering the hull of a ship to be constructed from plate elements connected...

  7. Single Photon Counting Performance and Noise Analysis of CMOS SPAD-Based Image Sensors

    Science.gov (United States)

    Dutton, Neale A. W.; Gyongy, Istvan; Parmesan, Luca; Henderson, Robert K.

    2016-01-01

    SPAD-based solid state CMOS image sensors utilising analogue integrators have attained deep sub-electron read noise (DSERN) permitting single photon counting (SPC) imaging. A new method is proposed to determine the read noise in DSERN image sensors by evaluating the peak separation and width (PSW) of single photon peaks in a photon counting histogram (PCH). The technique is used to identify and analyse cumulative noise in analogue integrating SPC SPAD-based pixels. The DSERN of our SPAD image sensor is exploited to confirm recent multi-photon threshold quanta image sensor (QIS) theory. Finally, various single and multiple photon spatio-temporal oversampling techniques are reviewed. PMID:27447643

  8. Analysis of a sub-shot-noise power recycled Michelson interferometer

    International Nuclear Information System (INIS)

    McKenzie, K; Buchler, B C; Shaddock, D A; Lam, P K; McClelland, D E

    2004-01-01

    The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods

  9. Benchmark Analysis of Subcritical Noise Measurements on a Nickel-Reflected Plutonium Metal Sphere

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Jesson Hutchinson

    2009-09-01

    Subcritical experiments using californium source-driven noise analysis (CSDNA) and Feynman variance-to-mean methods were performed with an alpha-phase plutonium sphere reflected by nickel shells, up to a maximum thickness of 7.62 cm. Both methods provide means of determining the subcritical multiplication of a system containing nuclear material. A benchmark analysis of the experiments was performed for inclusion in the 2010 edition of the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Benchmark models have been developed that represent these subcritical experiments. An analysis of the computed eigenvalues and the uncertainty in the experiment and methods was performed. The eigenvalues computed using the CSDNA method were very close to those calculated using MCNP5; however, computed eigenvalues are used in the analysis of the CSDNA method. Independent calculations using KENO-VI provided similar eigenvalues to those determined using the CSDNA method and MCNP5. A slight trend with increasing nickel-reflector thickness was seen when comparing MCNP5 and KENO-VI results. For the 1.27-cm-thick configuration the MCNP eigenvalue was approximately 300 pcm greater. The calculated KENO eigenvalue was about 300 pcm greater for the 7.62-cm-thick configuration. The calculated results were approximately the same for a 5-cm-thick shell. The eigenvalues determined using the Feynman method are up to approximately 2.5% lower than those determined using either the CSDNA method or the Monte Carlo codes. The uncertainty in the results from either method was not large enough to account for the bias between the two experimental methods. An ongoing investigation is being performed to assess what potential uncertainties and/or biases exist that have yet to be properly accounted for. The dominant uncertainty in the CSDNA analysis was the uncertainty in selecting a neutron cross-section library for performing the analysis of the data. The uncertainty in the

  10. Electrochemical capacitor

    Science.gov (United States)

    Anderson, Marc A.; Liu, Kuo -Chuan; Mohr, Charles M.

    1999-10-05

    An inexpensive porous metal oxide material having high surface area, good conductivity and high specific capacitance is advantageously used in an electrochemical capacitor. The materials are formed in a sol-gel process which affords control over the properties of the resultant metal oxide materials.

  11. Electrochemical construction

    Science.gov (United States)

    Einstein, Harry; Grimes, Patrick G.

    1983-08-23

    An electrochemical cell construction features a novel co-extruded plastic electrode in an interleaved construction with a novel integral separator-spacer. Also featured is a leak and impact resistant construction for preventing the spill of corrosive materials in the event of rupture.

  12. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  13. Electrochemical Cell

    DEFF Research Database (Denmark)

    1999-01-01

    The invention relates to a rechargeable electrochemical cell comprising a negative electrode, an electrolyte and a positive electrode in which the positive electrode structure comprises a lithium cobalt manganese oxide of the composition Li¿2?Co¿y?Mn¿2-y?O¿4? where 0 ... for capacity losses in lithium ion cells and lithium-alloy cells....

  14. Passive Noise Analysis for Advanced Tamper Indication. End of Year Report 2015

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Benjamin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Sanders, Jeff [Idaho National Lab. (INL), Idaho Falls, ID (United States); West, James [Idaho National Lab. (INL), Idaho Falls, ID (United States); Svoboda, John [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    Idaho National Laboratory (INL) is part of a multi-lab project assessing front-end electronics for unattended measurement (FEUM) being developed for the International Atomic Energy Agency (IAEA) unattended systems. The FEUM development activity provides an opportunity to address tampering detection between FEUM and the detector, signal integrity from FEUM to the data acquisition systems, and data validity – long-standing challenges for the IAEA. This report summarizes the INL activities in Fiscal Year (FY) 2015 to characterize and test passive noise analysis as a potential tamper-indicating approach for implementation into FEUM or as a stand-alone method. The project’s primary objectives in FY-15 were to (1) determine detectable tamper scenarios using four pre-amplifier/detector systems, (2) perform tests of tampering scenarios with three common cable types used by the IAEA, (3) separate radio-frequency-induced events from inherent effect by means of an anechoic chamber, and (4) perform tests at an industrial facility. General conclusions were reached in several areas.

  15. Root locus analysis and design of the adaptation process in active noise control.

    Science.gov (United States)

    Tabatabaei Ardekani, Iman; Abdulla, Waleed H

    2012-10-01

    This paper applies root locus theory to develop a graphical tool for the analysis and design of adaptive active noise control systems. It is shown that the poles of the adaptation process performed in these systems move on typical trajectories in the z-plane as the adaptation step-size varies. Based on this finding, the dominant root of the adaptation process and its trajectory can be determined. The first contribution of this paper is formulating parameters of the adaptation process root locus. The next contribution is introducing a mechanism for modifying the trajectory of the dominant root in the root locus. This mechanism creates a single open loop zero in the original root locus. It is shown that appropriate localization of this zero can cause the dominant root of the locus to be pushed toward the origin, and thereby the adaptation process becomes faster. The validity of the theoretical findings is confirmed in an experimental setup which is implemented using real-time multi-threading and multi-core processing techniques.

  16. Electrochemically deposited conducting polymers for reliable biomedical interfacing materials: Formulation, mechanical characterization, and failure analysis

    Science.gov (United States)

    Qu, Jing

    Conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) are of interest for a variety of applications including interfaces between electronic biomedical devices and living tissue. These polymers provide an improved interface compared to metal and semiconducting electrodes because of their ionic conductivity, relatively lower stiffness, and ability to incorporate biological molecules. Even though the signal transfer and biocompatibility of conjugated polymers are superior compared as the biointerfacing materials, the durability has been the weakest part for the long-term applications. Even though some efforts have been made to improve the durability of conjugated polymers, little quantitative information of the improved cohesion, adhesion and durability has been reported. In this thesis, the methods of improving the durability of conjugated polymer films, especially PEDOT, were investigated, including alternating the processing methods and components in synthesis. The 7-month in vivo testing showed that the durability of PEDOT films still needed to be improved. As a coating for biosignal transfer, the cohesion, adhesion and electrochemical stability of PEDOT are vital to determine the long-term performance. Not much information hd been developed around the cohesion and adhesion. A thin film cracking method was developed to measure the stiffness, strength and the interfacial shear strength (adhesion) of electrochemically deposited PEDOT. The estimated Young’s modulus of the PEDOT films was 2.6 ± 1.4 GPa, and the strain to failure was around 2%. The tensile strength was measured to be 56 ± 27 MPa. The effectiveness of crosslinker and adhesion promoter was demonstrated by this method. It was shown that 5 mole% addition of a tri-functional EDOT crosslinker (EPh) increased the tensile strength of the films to 283 ± 67 MPa, while the strain to failure remained about the same (2%). With the modification of EDOT-acid to the surface of stainless steel

  17. Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang Kai; Huang, Shih-Ying; Packard, Nathan J.; Boone, John M. [Department of Radiology, University of California, Davis Medical Center, 4860 Y Street, Suite 3100 Ellison Building, Sacramento, California 95817 (United States); Department of Radiology, University of California, Davis Medical Center, 4860 Y Street, Suite 3100 Ellison Building, Sacramento, California 95817 (United States) and Department of Biomedical Engineering, University of California, Davis, Davis, California, 95616 (United States)

    2010-07-15

    Purpose: A simplified linear model approach was proposed to accurately model the response of a flat panel detector used for breast CT (bCT). Methods: Individual detector pixel mean and variance were measured from bCT projection images acquired both in air and with a polyethylene cylinder, with the detector operating in both fixed low gain and dynamic gain mode. Once the coefficients of the linear model are determined, the fractional additive noise can be used as a quantitative metric to evaluate the system's efficiency in utilizing x-ray photons, including the performance of different gain modes of the detector. Results: Fractional additive noise increases as the object thickness increases or as the radiation dose to the detector decreases. For bCT scan techniques on the UC Davis prototype scanner (80 kVp, 500 views total, 30 frames/s), in the low gain mode, additive noise contributes 21% of the total pixel noise variance for a 10 cm object and 44% for a 17 cm object. With the dynamic gain mode, additive noise only represents approximately 2.6% of the total pixel noise variance for a 10 cm object and 7.3% for a 17 cm object. Conclusions: The existence of the signal-independent additive noise is the primary cause for a quadratic relationship between bCT noise variance and the inverse of radiation dose at the detector. With the knowledge of the additive noise contribution to experimentally acquired images, system modifications can be made to reduce the impact of additive noise and improve the quantum noise efficiency of the bCT system.

  18. High-order noise analysis for low dose iterative image reconstruction methods: ASIR, IRIS, and MBAI

    Science.gov (United States)

    Do, Synho; Singh, Sarabjeet; Kalra, Mannudeep K.; Karl, W. Clem; Brady, Thomas J.; Pien, Homer

    2011-03-01

    Iterative reconstruction techniques (IRTs) has been shown to suppress noise significantly in low dose CT imaging. However, medical doctors hesitate to accept this new technology because visual impression of IRT images are different from full-dose filtered back-projection (FBP) images. Most common noise measurements such as the mean and standard deviation of homogeneous region in the image that do not provide sufficient characterization of noise statistics when probability density function becomes non-Gaussian. In this study, we measure L-moments of intensity values of images acquired at 10% of normal dose and reconstructed by IRT methods of two state-of-art clinical scanners (i.e., GE HDCT and Siemens DSCT flash) by keeping dosage level identical to each other. The high- and low-dose scans (i.e., 10% of high dose) were acquired from each scanner and L-moments of noise patches were calculated for the comparison.

  19. On the Performance Analysis of Digital Communication Systems Perturbed by Non-Gaussian Noise and Interference

    KAUST Repository

    Soury, Hamza

    2016-06-29

    The Gaussian distribution is typically used to model the additive noise affecting communication systems. However, in many cases the noise cannot be modeled by a Gaussian distribution. In this thesis, we investigate the performance of different communication systems perturbed by non-Gaussian noise. Three families of noise are considered in this work, namely the generalized Gaussian noise, the Laplace noise/interference, and the impulsive noise that is modeled by an α-stable distribution. More specifically, in the first part of this thesis, the impact of an additive generalized Gaussian noise is studied by computing the average symbol error rate (SER) of one dimensional and two dimensional constellations in fading environment. We begin by the simple case of two symbols, i.e. binary phase shift keying (BPSK) constellation. From the results of this constellation, we extended the work to the average SER of an M pulse amplitude modulation (PAM). The first 2 − D constellation is the M quadrature amplitude modulation (QAM) (studied for two geometric shapes, namely square and rectangular), which is the combination of two orthogonal PAM signals (in-phase and quadrature phase PAM). In the second part, the system performance of a circular constellation, namely M phase shift keying (MPSK) is studied in conjunction with a Laplace noise with independent noise components. A closed form and an asymptotic expansion of the SER are derived for two detectors, maximum likelihood and minimum distance detectors. Next, we look at the intra cell interference of a full duplex cellular network which is shown to follow a Laplacian distribution with dependent, but uncorrelated, complex components. The densities of that interference are expressed in a closed form in order to obtain the SER of several communication systems (BPSK, PAM, QAM, and MPSK). Finally, we study the statistics of the α-stable distribution. Those statistics are expressed in closed form in terms of the Fox H function and

  20. Electrochemical biosensors for hormone analyses.

    Science.gov (United States)

    Bahadır, Elif Burcu; Sezgintürk, Mustafa Kemal

    2015-06-15

    Electrochemical biosensors have a unique place in determination of hormones due to simplicity, sensitivity, portability and ease of operation. Unlike chromatographic techniques, electrochemical techniques used do not require pre-treatment. Electrochemical biosensors are based on amperometric, potentiometric, impedimetric, and conductometric principle. Amperometric technique is a commonly used one. Although electrochemical biosensors offer a great selectivity and sensitivity for early clinical analysis, the poor reproducible results, difficult regeneration steps remain primary challenges to the commercialization of these biosensors. This review summarizes electrochemical (amperometric, potentiometric, impedimetric and conductometric) biosensors for hormone detection for the first time in the literature. After a brief description of the hormones, the immobilization steps and analytical performance of these biosensors are summarized. Linear ranges, LODs, reproducibilities, regenerations of developed biosensors are compared. Future outlooks in this area are also discussed. Copyright © 2014 Elsevier B.V. All rights reserved.