WorldWideScience

Sample records for electricity distribution companies

  1. Explaining the inefficiency of electrical distribution companies. Peruvian firms

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Reyes, Raul [Organismo Supervisor de la Inversion en Energia y Mineria, OSINERGMIN (Peru); Tovar, Beatriz [Infrastructure and Transport Research Group (EIT), Department of Applied Economics, University of Palmas de Gran Canaria (Spain)

    2010-09-15

    This paper investigates the extent to which the structural reform of the Peruvian electricity market, implemented in the 1990s, has improved the efficiency of the distribution companies; and it evaluates the influence on efficiency of firm specific explanatory variables. To do this, we rely on data from 14 distribution companies between 1996 and 2006. The results indicate that the incentives generated by the reform process led to the firms becoming more efficient. Moreover, the time trend and private management of the distribution companies are variables that positively affect the levels of efficiency, whereas the lower network densities are then the greater the inefficiency. (author)

  2. Measuring efficiency and productivity change (PTF) in the Peruvian electricity distribution companies after reforms

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Reyes, Raul [Organismo Supervisor de la Inversion en Energia y Mineria, Osinergmin (Peru); Tovar, Beatriz [Infrastructure and Transport Research Group (EIT), Department of Applied Economics, University of Palmas de Gran Canaria (Spain)

    2009-06-15

    This paper analyzes the evolution of productivity of the electricity distribution companies in Peru, to assess whether reforms have improved the efficiency in this sector. The paper also identifies potential sources of productivity changes, based on market restructuring the electricity sector and changes in property. To do this, we rely on a set of data for 14 distribution companies, for the period 1996-2006. Our analysis suggests that improvements in the efficiency and productivity of electricity distribution in Peru have occurred, and that there is a relationship between the restructuring of distribution sector and the enhancement of productivity. (author)

  3. Training Needs Assessment of Technical Skills in Managers of Tehran Electricity Distribution Company

    Science.gov (United States)

    Koohi, Amir Hasan; Ghandali, Fatemeh; Dehghan, Hasan; Ghandali, Najme

    2016-01-01

    Current dissertation has been conducted in order to investigate and detect training needs of the mangers (top and middle) in Tehran Electricity Distribution Company. Research method is applied kind based on its purpose. Due to data collection method, this query is descriptive-survey type. Statistical population in this study is all of managers in…

  4. Optimal Scale in Different Environments – The Case of Norwegian Electricity Distribution Companies

    OpenAIRE

    Cheng, Xiaomei; Bjørndal, Endre; Bjørndal, Mette

    2015-01-01

    We study returns to scale in Norwegian electricity distribution companies. The scale issue of this sector has become an important political question, and it was for instance discussed by the Reiten commission (OED, 2014) in a study about the future structure and organization of the Norwegian electricity network industry. We use panel data from the Norwegian Water Resources and Energy Directorate (NVE) for the period from 2004 to 2010. The Data Envelopment Analysis (DEA) method and the Stochas...

  5. Optimal Scale in Different Environments – The Case of Norwegian Electricity Distribution Companies

    OpenAIRE

    Cheng, Xiaomei; Bjørndal, Endre; Bjørndal, Mette

    2015-01-01

    We study returns to scale in Norwegian electricity distribution companies. The scale issue of this sector has become an important political question, and it was for instance discussed by the Reiten commission (OED, 2014) in a study about the future structure and organization of the Norwegian electricity network industry. We use panel data from the Norwegian Water Resources and Energy Directorate (NVE) for the period from 2004 to 2010. The Data Envelopment Analysis (DEA) method ...

  6. Electric distribution systems

    CERN Document Server

    Sallam, A A

    2010-01-01

    "Electricity distribution is the penultimate stage in the delivery of electricity to end users. The only book that deals with the key topics of interest to distribution system engineers, Electric Distribution Systems presents a comprehensive treatment of the subject with an emphasis on both the practical and academic points of view. Reviewing traditional and cutting-edge topics, the text is useful to practicing engineers working with utility companies and industry, undergraduate graduate and students, and faculty members who wish to increase their skills in distribution system automation and monitoring."--

  7. An ex ante welfare analysis of the unbundling of the distribution and supply companies in the Dutch electricity sector

    NARCIS (Netherlands)

    de Nooij, M.; Baarsma, B.

    2008-01-01

    The Dutch Minister of Economic Affairs intends (i) to unbundle the distribution companies from the commercial companies which are currently in the same holding (supply and generation) and (ii) to allow the Transmission System Operator to manage all the 110 kV grids (currently it manages the 220 kV

  8. The ANEEL and the criteria for the resource application in energy efficiency of the electric energy distribution companies; A ANEEL e os criterios para aplicacao de recursos em programas de eficiencia energetica das distribuidoras de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, Jamil [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Inst. de Sistemas Eletrico e Energia. Grupo de Estudos Energeticos (GEE)]. E-mail: jamil@unifei.edu.br

    2006-07-01

    Each year the ANEEL establishes the criteria for the of the Energy Efficiency Programs of the electric power distribution companies. This subject has an importance nevertheless to be highlighted only when conjunctural circumstances occur such as the 2001/2002 electric energy crisis. Such characteristics increase the ANEEL responsibility, because the regulation must observe the structural character which performs the energy efficiency actions. Recently, the ANEEL altered the criteria for the resource application by the electric power distribution companies. This article describes the importance of the energy efficiency and make comments on these frequent regulatory changes. (author)

  9. Risk-Based Bi-Level Model for Simultaneous Profit Maximization of a Smart Distribution Company and Electric Vehicle Parking Lot Owner

    Directory of Open Access Journals (Sweden)

    S. Muhammad Bagher Sadati

    2017-10-01

    Full Text Available In this paper, the effect of renewable energy resources (RERs, demand response (DR programs and electric vehicles (EVs is evaluated on the optimal operation of a smart distribution company (SDISCO in the form of a new bi-level model. According to the existence of private electric vehicle parking lots (PLs in the network, the aim of both levels is to maximize the profits of SDISCO and the PL owners. Furthermore, due to the uncertainty of RERs and EVs, the conditional value-at-risk (CVaR method is applied in order to limit the risk of expected profit. The model is transformed into a linear single-level model by the Karush–Kuhn–Tucker (KKT conditions and tested on the IEEE 33-bus distribution system over a 24-h period. The results show that by using a proper charging/discharging schedule, as well as a time of use program, SDISCO gains more profit. Furthermore, by increasing the risk aversion parameter, this profit is reduced.

  10. Hawaiian Electric Company Demand Response Roadmap Project

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Roger [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kiliccote, Sila [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-01-12

    The objective of this project was to develop a “roadmap” to guide the Hawaiian Electric Company (HECO) demand response (DR) planning and implementation in support of the Hawaii Clean Energy Initiative (HCEI) 70% clean energy goal by 2030.

  11. MODERN ELECTRIC CARS OF TESLA MOTORS COMPANY

    National Research Council Canada - National Science Library

    O. F. Vynakov; E. V. Savolova; A. I. Skrynnyk

    2016-01-01

    This overview article shows the advantages of a modern electric car as compared with internal combustion cars by the example of the electric vehicles of Tesla Motors Company. It (в смысле- статья...

  12. MODERN ELECTRIC CARS OF TESLA MOTORS COMPANY

    Directory of Open Access Journals (Sweden)

    O. F. Vynakov

    2016-08-01

    Full Text Available This overview article shows the advantages of a modern electric car as compared with internal combustion cars by the example of the electric vehicles of Tesla Motors Company. It (в смысле- статья describes the history of this firm, provides technical and tactical characteristics of three modifications of electric vehicles produced by Tesla Motors. Modern electric cars are not less powerful than cars with combustion engines both in speed and acceleration amount. They are reliable, economical and safe in operation. With every year the maximum range of an electric car is increasing and its battery charging time is decreasing.Solving the problem of environmental safety, the governments of most countries are trying to encourage people to switch to electric cars by creating subsidy programs, lending and abolition of taxation. Therefore, the advent of an electric vehicle in all major cities of the world is inevitable.

  13. Electric power distribution handbook

    CERN Document Server

    Short, Thomas Allen

    2014-01-01

    Of the ""big three"" components of electrical infrastructure, distribution typically gets the least attention. In fact, a thorough, up-to-date treatment of the subject hasn't been published in years, yet deregulation and technical changes have increased the need for better information. Filling this void, the Electric Power Distribution Handbook delivers comprehensive, cutting-edge coverage of the electrical aspects of power distribution systems. The first few chapters of this pragmatic guidebook focus on equipment-oriented information and applications such as choosing transformer connections,

  14. Electric utility companies and geothermal power

    Science.gov (United States)

    Pivirotto, D. S.

    1976-01-01

    The requirements of the electric utility industry as the primary potential market for geothermal energy are analyzed, based on a series of structured interviews with utility companies and financial institution executives. The interviews were designed to determine what information and technologies would be required before utilities would make investment decisions in favor of geothermal energy, the time frame in which the information and technologies would have to be available, and the influence of the governmental politics. The paper describes the geothermal resources, electric utility industry, its structure, the forces influencing utility companies, and their relationship to geothermal energy. A strategy for federal stimulation of utility investment in geothermal energy is suggested. Possibilities are discussed for stimulating utility investment through financial incentives, amelioration of institutional barriers, and technological improvements.

  15. 76 FR 24465 - Pacific Gas and Electric Company

    Science.gov (United States)

    2011-05-02

    ... Energy Regulatory Commission Pacific Gas and Electric Company Notice of Application Tendered for Filing....: 2310-193. c. Date Filed: April 12, 2011. d. Applicant: Pacific Gas and Electric Company. e. Name of... Contact: Steve Peirano, Relicensing Project Manager, Pacific Gas and Electric Company, P.O. Box 770000...

  16. 78 FR 38195 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-06-26

    ...; AD 2013-10-52] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines...) Applicability General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with a transfer gearbox... are adopting a new airworthiness directive (AD) for all General Electric Company (GE) GE90-110B1 and...

  17. FMCG companies specific distribution channels

    Directory of Open Access Journals (Sweden)

    Ioana Barin

    2009-12-01

    Full Text Available Distribution includes all activities undertaken by the producer, alone or in cooperation, since the end of the final finished products or services until they are in possession of consumers. The distribution consists of the following major components: distribution channels or marketing channels, which together form a distribution network; logistics o rphysical distribution. In order to effective achieve, distribution of goods requires an amount of activities and operational processes related to transit of goods from producer to consumer, the best conditions, using existing distribution channels and logistics system. One of the essential functions of a distribution is performing acts of sale, through which, with the actual movement of goods, their change of ownership takes place, that the successive transfer of ownership from producer to consumer. This is an itinerary in the economic cycle of goods, called the distribution channel.

  18. Electricity Distribution Effectiveness

    OpenAIRE

    Waldemar Szpyra; Wiesław Nowak; Rafał Tarko

    2015-01-01

    This paper discusses the basic concepts of cost accounting in the power industry and selected ways of assessing the effectiveness of electricity distribution. The results of effectiveness analysis of MV/LV distribution transformer replacement are presented, and unit costs of energy transmission through various medium-voltage line types are compared. The calculation results confirm the viability of replacing transformers manufactured before 1975. Replacing transformers manufactured after...

  19. FMCG companies specific distribution channels

    National Research Council Canada - National Science Library

    Ioana Barin

    2009-01-01

    ... existing distribution channels and logistics system. One of the essential functions of a distribution is performing acts of sale, through which, with the actual movement of goods, their change of ownership takes place, that the successive transfer of ownership from producer to consumer. This is an itinerary in the economic cycle of goods, called the distribution channel.

  20. Valuating the Investment Efficiency of Distribution Companies

    Directory of Open Access Journals (Sweden)

    M. Karajica

    2007-01-01

    Full Text Available The task of this study is to valuate the investment efficiency of distribution companies. Although a series of publications and studies has been dedicated to this topic, it is difficult to find a general consensus in defining the investment efficiency of a company. Nevertheless if we simplify an imaginary  company as a production unit in which a series of actions transforms inputs to outputs, efficiency can be understood as like an effort to achieve maximum value of the outputs together with minimum usage of inputs, where the inputs constitute investments by a company. The investment efficiency of a company can be measured by expressing the absolute values of selected inputs and outputs, a relative expression of inputs and outputs, and perhaps an expression of the difference between them. However, an examination of the efficiency of a certain company is impossible without a valuation of other companies. In view of the amount of benchmarking, it should be emphasized, that this study is dedicated to a certain category of benchmarking, which we may term investment benchmarking. This benchmarking can be defined as a comparison of companies in terms investment efficiency. The purpose of this comparison is not only to investigate levels of investment efficiency and to relate them to other companies from the same branch, but also to locate the greatest efficiency and indicate potential improvement. 

  1. 77 FR 65419 - Virginia Electric and Power Company

    Science.gov (United States)

    2012-10-26

    ... and Power Company AGENCY: Nuclear Regulatory Commission. ACTION: Partial Director's Decision; issuance... Power Station, Units 1 and 2 (North Anna 1 and 2), by the Virginia Electric and Power Company (VEPCO or... August 23, 2011, Virginia Electric and Power Company (the licensee) should be required to obtain a...

  2. 77 FR 26321 - Virginia Electric and Power Company

    Science.gov (United States)

    2012-05-03

    ... Power Company AGENCY: Nuclear Regulatory Commission. ACTION: Director's Decision; issuance. SUMMARY: The... Electric and Power Company (VEPCO or the licensee). The petition requested that the NRC: (1) Take escalated... be formally communicated to Virginia Electric and Power Company (VEPCO) in a written correspondence...

  3. Electricity Distribution Effectiveness

    Directory of Open Access Journals (Sweden)

    Waldemar Szpyra

    2015-12-01

    Full Text Available This paper discusses the basic concepts of cost accounting in the power industry and selected ways of assessing the effectiveness of electricity distribution. The results of effectiveness analysis of MV/LV distribution transformer replacement are presented, and unit costs of energy transmission through various medium-voltage line types are compared. The calculation results confirm the viability of replacing transformers manufactured before 1975. Replacing transformers manufactured after 1975 – only to reduce energy losses – is not economically justified. Increasing use of a PAS type line for energy transmission in local distribution networks is reasonable. Cabling these networks under the current calculation rules of discounts for excessive power outages is not viable, even in areas particularly exposed to catastrophic wire icing.

  4. 78 FR 44899 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-07-25

    ... Electric Company (GE) GE90-110B1 and -115B turbofan engines. This proposed AD was prompted by multiple... This AD applies to General Electric Company (GE) GE90-110B1 and -115B turbofan engines with variable... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric...

  5. 78 FR 19628 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-02

    ... Electric Company (GE) GE90-76B, -85B, -90B, -94B, - 110B1, and -115B turbofan engines. This proposed AD was... AD applies to General Electric Company (GE): (1) GE90-76B, -85B, -90B, and -94B turbofan engines with... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric...

  6. Smart grids concept in electrical distribution system

    Directory of Open Access Journals (Sweden)

    Popović Željko N.

    2012-01-01

    Full Text Available This paper defines key business processes in electrical distribution systems and key elements and priority components that should be (redefined in these processes in order to enable the goals of smart grids concept to be fulfilled in the cost effective way. Activities undertaken in the Power Distribution Company of “Elektrovojvodina” (Serbia, which provide the basis for fulfilling the Smart Grids goals and thus enable full implementation of smart grids concept are presented in details.

  7. 75 FR 18201 - Wisconsin Electric Power Company; Notice of Filing

    Science.gov (United States)

    2010-04-09

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Wisconsin Electric Power Company; Notice of Filing April 2, 2010. Take notice that on March 26, 2010, Wisconsin Electric Power Company filed counterpart signature pages to the...

  8. 78 FR 76045 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-12-16

    ... General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with high pressure compressor (HPC...-30-AD; Amendment 39-17694; AD 2013-24-17] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule; request...

  9. 78 FR 47534 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-08-06

    ... General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with affected transfer gearbox...-17-AD; Amendment 39-17536; AD 2013-15-20] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule; request...

  10. 78 FR 50320 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-08-19

    ...) Applicability This AD applies to all General Electric Company (GE) model GEnx- 2B67B turbofan engines with...-08-AD; Amendment 39-17553; AD 2013-16-15] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY...

  11. 77 FR 58471 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-09-21

    ...-30-AD; Amendment 39-17203; AD 2012-19-08] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule; request for comments. SUMMARY: We are adopting a new airworthiness directive (AD) for General Electric Company...

  12. 78 FR 72552 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-12-03

    ...-18-AD; Amendment 39-17669; AD 2013-23-14] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for certain General Electric Company model GEnx...

  13. 77 FR 3088 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-01-23

    ...-10] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal... directive (AD) for General Electric Company (GE) CF34-10E series turbofan engines. This AD was prompted by a... affected engines if wear is found on either the CVD support ring or the fan drive shaft. We are issuing...

  14. 78 FR 56594 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-09-13

    ... General Electric Company (GE): (1) GE90-76B, -85B, -90B, and -94B turbofan engines with stage 1 high...-11-AD; Amendment 39-17571; AD 2013-17-07] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY...

  15. 77 FR 76977 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-12-31

    ... Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Supplemental... proposed airworthiness directive (AD) for certain General Electric Company (GE) CF6-80C2 series turbofan engines. That NPRM proposed to supersede an AD that required replacement of fuel tubes connected to the...

  16. 78 FR 19983 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-03

    ...-37-AD; Amendment 39-17403; AD 2013-06-06] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for General Electric Company (GE) CF34-8C and CF34...

  17. 78 FR 21578 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-11

    ... Electric Company (GE) model GEnx- 2B67 and GEnx-2B67B turbofan engines with booster anti-ice (BAI) air duct... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed...

  18. 77 FR 48110 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-08-13

    ... certain General Electric Company (GE) CF6-80C2 series turbofan engines. The existing AD requires... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed...

  19. 78 FR 72567 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-12-03

    ... General Electric Company (GE) GE90-110B1 and -115B turbofan engines with variable bypass valve (VBV...-20-AD; Amendment 39-17673; AD 2013-23-18] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY...

  20. 78 FR 47235 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-08-05

    ... Electric Company (GE) model GEnx-2B67 and GEnx-2B67B turbofan engines. This proposed AD was prompted by the... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed...

  1. 17 CFR 250.7 - Companies deemed not to be electric or gas utility companies.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Companies deemed not to be electric or gas utility companies. 250.7 Section 250.7 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, PUBLIC UTILITY HOLDING COMPANY ACT OF 1935...

  2. Protection of electricity distribution networks

    CERN Document Server

    Gers, Juan M

    2004-01-01

    Written by two practicing electrical engineers, this second edition of the bestselling Protection of Electricity Distribution Networks offers both practical and theoretical coverage of the technologies, from the classical electromechanical relays to the new numerical types, which protect equipment on networks and in electrical plants. A properly coordinated protection system is vital to ensure that an electricity distribution network can operate within preset requirements for safety for individual items of equipment, staff and public, and the network overall. Suitable and reliable equipment sh

  3. 78 FR 72877 - Arkansas Electric Corporation v. Oklahoma Gas and Electric Company; Notice of Complaint

    Science.gov (United States)

    2013-12-04

    ... Energy Regulatory Commission Arkansas Electric Corporation v. Oklahoma Gas and Electric Company; Notice... Procedure of the Federal Energy Regulatory Commission (Commission), 18 CFR 385.206, Arkansas Electric Corporation (Complainant) filed a formal complaint against Oklahoma Gas and Electric Company (Respondents...

  4. Energy Systems Integration: NREL + SolarCity and the Hawaiian Electric Companies (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2015-02-01

    This fact sheet describes the collaboration between NREL, SolarCity, and the Hawaiian Electric Companies at the Energy Systems Integration Facility (ESIF) to address the safety, reliability, and stability challenges of interconnecting high penetrations of distributed photovoltaics with the electric power system.

  5. Trading Strategies for Distribution Company with Stochastic Distributed Energy Resources

    DEFF Research Database (Denmark)

    Zhang, Chunyu; Wang, Qi; Wang, Jianhui

    2016-01-01

    This paper proposes a methodology to address the trading strategies of a proactive distribution company (PDISCO) engaged in the transmission-level (TL) markets. A one-leader multi-follower bilevel model is presented to formulate the gaming framework between the PDISCO and markets. The lower...

  6. 77 FR 74125 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2012-12-13

    ... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking (NPRM). SUMMARY: We propose to adopt a new airworthiness directive (AD) for all General Electric...

  7. 76 FR 67594 - Airworthiness Directives; General Electric Company Turboshaft Engines

    Science.gov (United States)

    2011-11-02

    ...-29-AD; Amendment 39-16840; AD 2011-21-17] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turboshaft Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule; request for comments. SUMMARY: We are adopting a new airworthiness directive (AD) for all General Electric...

  8. 78 FR 24671 - Airworthiness Directives; General Electric Company Turbofan Engines

    Science.gov (United States)

    2013-04-26

    ... Electric Company (GE) CF6-80C2 A1/A2/A3/A5/A8/A5F/B1/B2/B4/B5F/B6/B1F/B2F/B4F/B6F/B7F/D1F turbofan engines...-AD; Amendment 39-17438; AD 2013-08-20] RIN 2120-AA64 Airworthiness Directives; General Electric Company Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY...

  9. Orchestration of Globally Distributed Knowledge for Innovation in Multinational Companies

    DEFF Research Database (Denmark)

    Sajadirad, Solmaz; Lassen, Astrid Heidemann

    2017-01-01

    Conducting a multiple-case study in five companies from Danish industry, this paper explores how multinational companies orchestrate knowledge from their globally distributed subsidiaries for innovation. Comparisons of knowledge orchestration within headquarter and subsidiaries for improvement...... globally distributed knowledge. This study contributes to the understanding of knowledge orchestration between headquarter and distributed subsidiaries in multinational companies and how it is related to innovation. Specifically, this paper has important implications regarding the use of inter-firm objects...

  10. Research on service strategy of electricity selling company under the reform of electricity market

    Science.gov (United States)

    Long, Zhuhan; Meng, Shiyu; Dou, Jinyue; Zeng, Ming; Sun, Chenjun

    2017-10-01

    The opening of the sale side of electricity market is an important goal of the new round of power system reform in China, and it is necessary to speed up the establishment and development of the electricity selling companies to achieve this goal. First of all, this paper defines the key problems, which are needed to be solved in the establishment of the sale side market, such as demand side response, optimization of users' power consumption mode, profit mode of electricity selling companies and fair competition in the market. On this basis, this paper analyzes the business of electricity selling company, from the aspects of the transition of business ideas, improving the energy efficiency level, providing integrated energy solutions and innovating business management mode; and then, the service strategies of electricity selling companies are put forward.

  11. Team Building. Baldor Electric Company. [Facilitator Guide and Participant Guide.

    Science.gov (United States)

    Saint Louis Community Coll., MO. Workplace Literacy Services Center.

    This document contains the facilitator and participant guides for a course in team building that was developed by a community college for a St. Louis (Missouri) electric company. The facilitator's guide contains the transparency masters, outlines, learning activities, questionnaires, and other handouts required for two course sessions. The first…

  12. 76 FR 61687 - Pacific Gas and Electric Company

    Science.gov (United States)

    2011-10-05

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Pacific Gas and Electric Company Notice of Availability of Environmental Assessment In accordance with the National Environmental Policy Act of 1969 and the Federal Energy Regulatory...

  13. Profiting from competition: Financial tools for electric generation companies

    Science.gov (United States)

    Richter, Charles William, Jr.

    Regulations governing the operation of electric power systems in North America and many other areas of the world are undergoing major changes designed to promote competition. This process of change is often referred to as deregulation. Participants in deregulated electricity systems may find that their profits will greatly benefit from the implementation of successful bidding strategies. While the goal of the regulators may be to create rules which balance reliable power system operation with maximization of the total benefit to society, the goal of generation companies is to maximize their profit, i.e., return to their shareholders. The majority of the research described here is conducted from the point of view of generation companies (GENCOs) wishing to maximize their expected utility function, which is generally comprised of expected profit and risk. Strategies that help a GENCO to maximize its objective function must consider the impact of (and aid in making) operating decisions that may occur within a few seconds to multiple years. The work described here assumes an environment in which energy service companies (ESCOs) buy and GENCOs sell power via double auctions in regional commodity exchanges. Power is transported on wires owned by transmission companies (TRANSCOs) and distribution companies (DISTCOs). The proposed market framework allows participants to trade electrical energy contracts via the spot, futures, options, planning, and swap markets. An important method of studying these proposed markets and the behavior of participating agents is the field of experimental/computational economics. For much of the research reported here, the market simulator developed by Kumar and Sheble and similar simulators has been adapted to allow computerized agents to trade energy. Creating computerized agents that can react as rationally or irrationally as a human trader is a difficult problem for which we have turned to the field of artificial intelligence. Some of our

  14. Trading strategies for distribution company with stochastic distributed energy resources

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chunyu; Wang, Qi; Wang, Jianhui; Korpås, Magnus; Pinson, Pierre; Østergaard, Jacob; Khodayar, Mohammad E.

    2016-09-01

    This paper proposes a methodology to address the trading strategies of a proactive distribution company (PDISCO) engaged in the transmission-level (TL) markets. A one-leader multi-follower bilevel model is presented to formulate the gaming framework between the PDISCO and markets. The lower-level (LL) problems include the TL day-ahead market and scenario-based real-time markets, respectively with the objectives of maximizing social welfare and minimizing operation cost. The upper-level (UL) problem is to maximize the PDISCO’s profit across these markets. The PDISCO’s strategic offers/bids interactively influence the outcomes of each market. Since the LL problems are linear and convex, while the UL problem is non-linear and non-convex, an equivalent primal–dual approach is used to reformulate this bilevel model to a solvable mathematical program with equilibrium constraints (MPEC). The effectiveness of the proposed model is verified by case studies.

  15. Transmission and distribution electrical engineering

    CERN Document Server

    Bayliss, Colin

    2003-01-01

    This comprehensive treatment of the theory and practice encountered in the installation and design of transmission and distribution systems for electrical power has been updated and revised to provide the project engineer with all the latest, relevant information to design and specify the correct system for a particular application.Thoroughly updated and revised to include latest developmentsLearn from and Author with extensive experience in managing international projectsFind out the reasoning and implicatons behind the different specifications and methods

  16. Controlling Elements In The Distribution Policy Of A Company

    Directory of Open Access Journals (Sweden)

    Pelau Corina

    2008-04-01

    Full Text Available In a permanent changing environment, the measurement and monitorisation of the performance of a company has become one of the key issues for its success. This fact increases the capacity of each company to adapt to the conditions of the environment, because only by a permanent monitorisation of the performance, a company can discover both its strenghts and its weaknesses and in time, it can react according to these. This paper concentrates on the controlling and performance measurement of the distribution policy of a company. It analyses both the efficacity and efficency of the distribution channels as well as the succes of the logistics activity.

  17. The development of multimedia communication system for electric power company

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Hee Gon; Kim, Seong Bok [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    It is a final report of the research project that is a development of PC-LAN based multimedia desktop conference system, which is research on the essential technologies and application and development of multimedia communication services for electric power company. This report is consisted of -Survey and study of the multimedia related technologies, -Multimedia communication protocols and network configurations, and -Design, developments of pilot model, evaluation, and applications of multimedia conference system. (author). 112 refs., 250 figs.

  18. 75 FR 18828 - Wisconsin Electric Power Company, Wisconsin Gas LLC, Wisconsin Public Service Corporation...

    Science.gov (United States)

    2010-04-13

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Wisconsin Electric Power Company, Wisconsin Gas LLC, Wisconsin Public....206 (2009), Wisconsin Electric Power Company, Wisconsin Gas LLC, and Wisconsin Public Service...

  19. Measures against emergency disasters taken by electric power companies, as seen in Kyushu Electric Power Company; Kyushu denryoku ni miru denryoku kaisha no hijo saigai taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Kakemoto, K. [Kyushu Electric Power Co. Inc., Fukuoka (Japan)

    1994-09-01

    This paper introduces measures against emergency disasters taken by Kyushu Electric Power Company. The paper summarizes the following items: the structure of the emergency disaster handling organizations in the company, steps taken prior to an occurrence of an anticipated disaster (identification of climate information, assurance of personnel to perform the measures and personnel required for restoration, assurance of restoration materials and equipment availability, and their arrangements in advance), and operations (restoration, public communications, and supports) taken by a preparatory organization when a disaster is anticipated and an emergency organization (for a case when a disaster may be expected to occur within several hours, or when it has occurred). The paper then summarizes the emergency disaster information system including the information collecting subsystem for hydro-electric power generation, power transformation, power transmission, communication, and civil engineering facilities, the information collecting (power failure information processing) subsystem for power distribution facilities, the power feeding and climate information collecting subsystem, the wind observation subsystem, and the kinds of information to be collected. The paper mentions additionally the number of houses having suffered power failure and facility damages in the company`s controlling areas during heavy rains and typhoons in 1993. 5 figs., 7 tabs.

  20. The level of diversity in European electricity companies based on selected economic indicators

    Directory of Open Access Journals (Sweden)

    Małgorzata Ulatowska

    2014-08-01

    Full Text Available The purpose of the article was to show variations in the electricity sector in the context of macro and micro-economic conditions with the use of discriminatory analysis. Using the STATISTICA programe to carry out the analysis of discrimination macroeconomic data has been used on the economies of the countries in which the parent companies of the energy companiesare established and the financial and economic results of individual concerns. Power companies: power plants, distribution companies and vendors of energy in Poland have been included as a single entity. An attempt to determine the factors of macro and micro-economic and financial data, which significantly affected the distinctionbetween the concerns was investigated. The results of the discriminatory analysis allowed for the submission of the following conclusions: selected on the basis of the following micro-economic factors distinguished the companies that had the largest share of variables: revenue per employee and long-term assets to long-term capital, and clearly distinguished EdF and electricity companies in Poland. This means that the dominant European companies show a similarity in implementation adopted by the owners of the economic-financial conditions for development. According to factors and the economic contribution to the largest macroeconomic identifying similar groups had the same variables: consumption of electricity in TWh and public debt in% of GDP, which correctly classified all concerns at 100%. It follows from this that the greatest contributions in distinguishing concerns have external factors and more specifically, the national macro-economic indicators in the countries in which the handquestors of the parent companies are found.

  1. Designing a Rational Distribution Network for Trading Companies

    Directory of Open Access Journals (Sweden)

    Dybskaya V. V.

    2017-09-01

    Full Text Available This article considers the modern methods and approaches to design the company’s distribution network. The authors point out the relevance of this problem for the modern trading and manufacturing companies, give examples of the strategic goal setting of the company in the logistics network reorganization, and the benchmarks of possible economic effects of its conduction. The work reviews the scientific articles of contemporary American, European and Russian authors devoted to the approaches, concerning the implementation of projects for designing a distribution network, methods and models for its optimization. The article concludes that there is no single “language” and an approach to design the logistics networks, with a proper level of detail that takes into account the strategic features and industry specificity of the certain company. The authors propose an algorithm for designing a rational distribution network.

  2. 77 FR 73634 - Wisconsin Electric Power Company; Notice of Application Accepted for Filing, Ready for...

    Science.gov (United States)

    2012-12-11

    ...-095] Wisconsin Electric Power Company; Notice of Application Accepted for Filing, Ready for..., Wisconsin Electric Power Company, 800 Industrial Park Drive, Iron Mountain, MI 49801, (906) 779-4099. i... License. b. Project No.: 11831-095. c. Date Filed: October 24, 2012. d. Applicant: Wisconsin Electric...

  3. 77 FR 40608 - Wisconsin Electric Power Company; Notice of Petition for Declaratory Order

    Science.gov (United States)

    2012-07-10

    ... Energy Regulatory Commission Wisconsin Electric Power Company; Notice of Petition for Declaratory Order...) Rules of Practice and Procedure, 18 CFR 381.302 and 385.207, Wisconsin Electric Power Company (Wisconsin Electric) submitted a petition requesting the Commission to issue a declaratory order approving: (1...

  4. 76 FR 64287 - Airworthiness Directives; General Electric Company CF34-10E Series Turbofan Engines

    Science.gov (United States)

    2011-10-18

    ... General Electric Company (GE) CF34-10E series turbofan engines. This proposed AD was ] prompted by a... This AD applies to General Electric Company (GE) CF34-10E series turbofan engines, serial number (S/N... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric...

  5. Distributed Coordination of Household Electricity Consumption

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Teixeira, Andre; Johansson, Mikael

    2014-01-01

    This work presents a distributed framework for coordination of flexible electricity consumption for a number of households in the distribution grid. We conduct coordination with the purpose of minimizing a trade-off between individual concerns about discomfort and electricity cost, on the one hand...

  6. Competencies Needed by Seed Production and Distribution Company Employees.

    Science.gov (United States)

    Morrow, Charles Kendall

    To determine competencies needed by employees in the seed production and distribution industry, a questionnaire containing 49 competencies was compiled with the assistance of specialists and mailed to 100 company managers and 200 nonmanagerial employees. Returns from the 200 usable questionnaires indicate that the competencies needed most by…

  7. [Documentation of good distribution practice of medicines and its implementation in Lithuanian drug distribution companies].

    Science.gov (United States)

    Draksiene, Gailute; Petkevicius, Henrikas; Radziūnas, Raimondas

    2003-01-01

    Good Distribution Practice of medicinal products for human use is a quality warranty system, which includes requirements for purchase, receiving, storage and export of drugs, intended human consumption. A drug is a specific product and its mishandling is dangerous to human health and life. Therefore it is necessary to strictly control the movement of the drug from the producer to the consumer so that poor quality drugs do not have access to the market. Good Distribution Practice rules set the general requirements for good wholesale distribution practice of drugs, intended for human consumption. In order for company to meet the specified requirements, the drug distribution company must have all suitable and necessary premises, machinery, equipment, the required number of employees and specified documentation. The preparation of the Good Distribution Practice documentation is one of the most important and complex aspects when implementing the Good Distribution Practice in the companies. The article deals with the analysis of results obtained during the research of drug distribution companies in Lithuania. The research revealed that drug distribution companies put emphasis on the equipment of storage premises. Less attention is being paid to the preparation of the documents of Good Distribution Practice. The article thus presents the analysis of Good Distribution Practice documents prepared by the drug distribution companies.

  8. Electrical utilities model for determining electrical distribution capacity

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, R. L.

    1997-09-03

    In its simplest form, this model was to obtain meaningful data on the current state of the Site`s electrical transmission and distribution assets, and turn this vast collection of data into useful information. The resulting product is an Electrical Utilities Model for Determining Electrical Distribution Capacity which provides: current state of the electrical transmission and distribution systems; critical Hanford Site needs based on outyear planning documents; decision factor model. This model will enable Electrical Utilities management to improve forecasting requirements for service levels, budget, schedule, scope, and staffing, and recommend the best path forward to satisfy customer demands at the minimum risk and least cost to the government. A dynamic document, the model will be updated annually to reflect changes in Hanford Site activities.

  9. Protection of electricity distribution networks

    CERN Document Server

    Gers, Juan; Institution of Engineering and Technology

    2011-01-01

    Combining a theoretical background with examples and exercises, this book allows the reader to easily follow requirements for high quality electrical service in utilities and industrial facilities around the world.

  10. Development of Reliability Indices for Electric Distribution Network in Egypt

    Directory of Open Access Journals (Sweden)

    Eman Ahmed

    2017-03-01

    Full Text Available Reliability indices (RIs are the elemental benchmark used by Egyptian Electricity Holding Company (EEHC, and the Electric Utility and Consumer Protection Regulatory Agency (Egypt ERA to evaluate the continuity and compliance of supply, which surpasses the customer's requirements and satisfaction. The power system is very complex, mixing huge different types of generating resources and clusters to supply electric power through transmission and distribution system to a number of customers with varying requirements.The main function of electric system is to supply customers with electric energy that has an acceptable degree of reliability and quality. The power system continuity of supply level is controlled through system indices. The most widely used reliability indices are SAIFI, SAIDI and CAIDI (IEEE std. 1366-2000.Historical electrical indices, reliability indices threshold and satisfaction index are used as guide for electric network performance, which measure the adequate and secure power supply.The paper presents the reliability indices, relation between indices and satisfaction area to highlight the appropriate guideline values for electric systems, also presents the development of indices since 2011 to now for distribution network in Egypt.

  11. Examination of Electric Utility CEO Compensation 2000-2011 and its significance to Company Earnings, Company Revenue, Company Stock and the Dow Jones Utility Average

    Science.gov (United States)

    Labovitch, Andrew

    This dissertation examined electric utility CEO compensation during the years 2000 through 2011 for United States owned and operated companies. To determine the extent to which agency theory may apply to electric utility CEO compensation, this examination segmented the industry by four types of company financial metrics: revenue, earnings, stock price and the Dow Jones Utility Average; by five categories of CEO compensation: base salary, bonus, stock grants, all other compensation and total compensation; and by four categories of company size as measured by revenue: large, medium, small and the industry as a whole. Electric utility CEO compensation data was analyzed with the financial metrics to determine correlations. No type of compensation was highly correlated to any of the financial metrics for any size industry segment indicating that there was little agency. CEO compensation in large electric utility companies was higher than compensation in medium and smaller companies even though the CEOs at larger companies earned less per dollar of revenue and per dollar of earnings than their counterparts in smaller companies.

  12. 76 FR 69713 - Application To Export Electric Energy; BP Energy Company

    Science.gov (United States)

    2011-11-09

    ... term. The electric energy that BP Energy proposes to export to Mexico would be surplus energy purchased... Application To Export Electric Energy; BP Energy Company AGENCY: Office of Electricity Delivery and Energy... its authority to transmit electric energy from the United States to Mexico pursuant to section 202(e...

  13. 78 FR 11633 - Application To Export Electric Energy; ConocoPhillips Company

    Science.gov (United States)

    2013-02-19

    ... electric energy that CoP proposes to export to Mexico will be surplus to the needs of the selling entities... Application To Export Electric Energy; ConocoPhillips Company AGENCY: Office of Electricity Delivery and... to renew its authority to transmit electric energy from the United States to Mexico pursuant to...

  14. Macroergonomic study of food sector company distribution centres.

    Science.gov (United States)

    García Acosta, Gabriel; Lange Morales, Karen

    2008-07-01

    This study focussed on the work system design to be used by a Colombian food sector company for distributing products. It considered the concept of participative ergonomics, where people from the commercial, logistics, operation, occupational health areas worked in conjunction with the industrial designers, ergonomists who methodologically led the project. As a whole, the project was conceived as having five phases: outline, diagnosis, modelling the process, scalability, instrumentation. The results of the project translate into procedures for selecting, projecting a new distribution centre, the operational process model, a description of ergonomic systems that will enable specific work stations to be designed, the procedure for adapting existing warehouses. Strategically, this work helped optimise the company's processes and ensure that knowledge would be transferred within it. In turn, it became a primary prevention strategy in the field of health, aimed at reducing occupational risks, improving the quality of life at work.

  15. 77 FR 28869 - Exelon Corporation, Public Service Electric and Gas Company, PSEG Power LLC, PSEG Energy...

    Science.gov (United States)

    2012-05-16

    ... Energy Regulatory Commission Exelon Corporation, Public Service Electric and Gas Company, PSEG Power LLC...(e), Exelon Corporation, Public Service Electric and Gas Company, PSEG Power LLC, and PSEG Energy... parties in EL12-63. Joint Complainants state that they are unable to confirm service on Unnamed...

  16. 75 FR 78979 - Application to Export Electric Energy; Twin Rivers Paper Company Inc.

    Science.gov (United States)

    2010-12-17

    ... Application to Export Electric Energy; Twin Rivers Paper Company Inc. AGENCY: Office of Electricity Delivery and Energy Reliability, DOE. ACTION: Notice of application. SUMMARY: Twin Rivers Paper Company Inc... line, operated at 69-kV, connect the integrated pulp and paper operations owned by Twin Rivers and its...

  17. 76 FR 12728 - Pacific Gas and Electric Company; Notice of Preliminary Permit Application Accepted for Filing...

    Science.gov (United States)

    2011-03-08

    ... new single-unit powerhouse with a turbine and generator constructed downstream of the right abutment... Energy Regulatory Commission Pacific Gas and Electric Company; Notice of Preliminary Permit Application..., 2011, Pacific Gas and Electric Company (PG&E) filed an application for a successive preliminary permit...

  18. 75 FR 39285 - Virginia Electric and Power Company: North Anna Power Station, Unit No. 1 Environmental...

    Science.gov (United States)

    2010-07-08

    ... COMMISSION Virginia Electric and Power Company: North Anna Power Station, Unit No. 1 Environmental Assessment...-4, issued to Virginia Electric and Power Company (the licensee), for operation of the North Anna... changes are being made in the types of effluents that may be released offsite. There is no significant...

  19. Green marketing in the Massachusetts electric company retail competition pilot program

    Energy Technology Data Exchange (ETDEWEB)

    Rothstein, S.M.; Fang, J.M.

    1997-10-01

    With electric industry restructuring initiatives being introduced on the state and federal levels, retail access pilot programs serve an important function for examining competitive market issues, as well as marketing strategies and customer reactions to different power supply options. The experience gained through these pilots provides important insights into future power market operations, including the market for green power. The Massachusetts Electric Company`s (MECo`s) Choice: New England pilot for residential and small-business customers was a voluntary program developed primarily to test the billing and metering logistics that distribution companies will need in the competitive market. The pilot also offered a preview of program implementation and marketing under customer choice. It was the first retail competition pilot to explicitly include green power options in program design. The MECo pilot`s energy suppliers were selected through the issuance of a request for proposals (RFP). Respondents were asked to submit bids in one or more of three energy supply categories-price, green, and other options. These options were developed by the pilot administrator through internal meetings, discussions with state officials and other stakeholders, and a review of information from other similar pilots. For the green option, the pilot administrator did not establish a green standard. Instead, suppliers were allowed to submit offers that promoted environmental stewardship. Customer response to the different green options are reported. The pilot results clearly demonstrate that, in a competitive situation, there is interest in a variety of energy supply options, including green options. 2 tabs.

  20. Evaluation of Public Service Electric & Gas Company`s standard offer program, Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, C.A.; Kito, M.S.; Moezzi, M.M.

    1995-07-01

    In May 1993, Public Service Electric and Gas (PSE&G), the largest investor-owned utility in New Jersey, initiated the Standard Offer program, an innovative approach to acquiring demand-side management (DSM) resources. In this program, PSE&G offers longterm contracts with standard terms and conditions to project sponsors, either customers or third-party energy service companies (ESCOs), on a first-come, first-serve basis to fill a resource block. The design includes posted, time-differentiated prices which are paid for energy savings that will be verified over the contract term (5, 10, or 15 years) based on a statewide measurement and verification (M&V) protocol. The design of the Standard Offer differs significantly from DSM bidding programs in several respects. The eligibility requirements and posted prices allow ESCOs and other energy service providers to market and develop projects among customers with few constraints on acceptable end use efficiency technologies. In contrast, in DSM bidding, ESCOs typically submit bids without final commitments from customers and the utility selects a limited number of winning bidders who often agree to deliver a pre-specified mix of savings from various end uses in targeted markets. The major objectives of the LBNL evaluation were to assess market response and customer satisfaction; analyze program costs and cost-effectiveness; review and evaluate the utility`s administration and delivery of the program; examine the role of PSE&G`s energy services subsidiary (PSCRC) in the program and the effect of its involvement on the development of the energy services industry in New Jersey; and discuss the potential applicability of the Standard Offer concept given current trends in the electricity industry (i.e., increasing competition and the prospect of industry restructuring).

  1. 78 FR 8193 - In the Matter of Virginia Electric and Power Company, and Old Dominion Electric Cooperative; ESP...

    Science.gov (United States)

    2013-02-05

    ... COMMISSION In the Matter of Virginia Electric and Power Company, and Old Dominion Electric Cooperative; ESP for North Anna ESP Site; Order Approving Direct Transfer of Early Site Permit and Approving Conforming... Dominion Electric Cooperative (ODEC), hold Early Site Permit 003 (ESP-003) for North Anna Site issued on...

  2. ANALYSING AND EVALUATING THE DISTRIBUTION SYSTEM OF THE DELACO COMPANY

    Directory of Open Access Journals (Sweden)

    EVELINA GRĂDINARU

    2011-01-01

    Full Text Available This paper contains a theoretical analysis of the term „distribution”, indicating the area to which it belongs, the usability domain and the strategies of distribution used by the consumer goods manufacturers. It also provides specific information about the way in which is made the distribution of the products of the Delaco Company on the retail market of Brasov District. The practice part of the paper consists of a marketing research which studies the opinion and the behaviour of the Brasov population regarding the places where cheese products are commercialized and also the accessibility of the Delaco products.

  3. Spare part management of an electricity distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Lauronen, J.

    1998-07-01

    Electricity distribution companies are required to improve their operational cost effectiveness. The storage systems of the companies have traditionally been based on the 'adequate' number of stores with plenty of different components. Therefore, they are potential objects for cost reduction. The effective operation of spare part management of an electricity distribution network requires that the spare components can be delivered at the fault site quickly in order to avoid excessive outage costs. In a fault situation the stores form a net structure. Currently the rural electricity distribution companies lack suitable methods for designing a spare part storage system. This thesis presents a suitable method for the designing problem. The models assume that faults of a distribution network are stochastic. Therefore, they are best suited for component types installed in large quantities. Improved methods for defining the outage, material and total costs for perpetual order quantity and periodic order-up-to-level storage control systems are described. The method for determining the control parameters of the stores is also presented and ways for finding the necessary initial parameter values are introduced. The developed method is tested in Haemeen Saehko Oy (HSOY). The results of the calculations are given. The key findings are: Small differences in the designing results can increase costs remarkably. For example, in HSOY too low stock levels can result in even eight folds higher outage costs than in the proper design. The best number of stores is not the same for all component types. For example, in HSOY the best number of stores is seven for the 50 kVA transformers and one for the 315 kVA transformers in a summer. If the stock levels are increased the protection against the demand variations is the better the shorter the duration of the review period and/or the replenishment lead time is. (orig.)

  4. Tampa Electric Company Polk Power Station IGCC project: Project status

    Energy Technology Data Exchange (ETDEWEB)

    McDaniel, J.E.; Carlson, M.R.; Hurd, R.; Pless, D.E.; Grant, M.D. [Tampa Electric Co., FL (United States)

    1997-12-31

    The Tampa Electric Company Polk Power Station is a nominal 250 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located to the southeast of Tampa, Florida in Polk County, Florida. This project is being partially funded under the Department of Energy`s Clean Coal Technology Program pursuant to a Round II award. The Polk Power Station uses oxygen-blown, entrained-flow IGCC technology licensed from Texaco Development Corporation to demonstrate significant reductions of SO{sub 2} and NO{sub x} emissions when compared to existing and future conventional coal-fired power plants. In addition, this project demonstrates the technical feasibility of commercial scale IGCC and Hot Gas Clean Up (HGCU) technology. The Polk Power Station achieved ``first fire`` of the gasification system on schedule in mid-July, 1996. Since that time, significant advances have occurred in the operation of the entire IGCC train. This paper addresses the operating experiences which occurred in the start-up and shakedown phase of the plant. Also, with the plant being declared in commercial operation as of September 30, 1996, the paper discusses the challenges encountered in the early phases of commercial operation. Finally, the future plans for improving the reliability and efficiency of the Unit in the first quarter of 1997 and beyond, as well as plans for future alternate fuel test burns, are detailed. The presentation features an up-to-the-minute update on actual performance parameters achieved by the Polk Power Station. These parameters include overall Unit capacity, heat rate, and availability. In addition, the current status of the start-up activities for the HGCU portion of the plant is discussed.

  5. 76 FR 6638 - Virginia Electric and Power Company D/B/A/ Dominion Virginia Power and Old Dominion Electric...

    Science.gov (United States)

    2011-02-07

    ... North Anna Power Station (NAPS) site located in Louisa County, Virginia. The NAPS property is located on... COMMISSION Virginia Electric and Power Company D/B/A/ Dominion Virginia Power and Old Dominion Electric Cooperative, North Anna Power Station Combined License Application; Notice of Intent To Prepare a Supplemental...

  6. L'Anse Warden Electric Company Boiler Number One Emission Test Report – March 2017

    Science.gov (United States)

    L’Anse Warden Electric Company (LWEC) submitted results from an emission test on the Boiler No. 1 stack. Stack air emission testing was conducted in March 2017, and the report became available in June 2017

  7. L'Anse Warden Electric Company Boiler Number One Emission Test Report – June 2017

    Science.gov (United States)

    L’Anse Warden Electric Company (LWEC) submitted results from an emission test on the Boiler No. 1 stack. Stack air emission testing was conducted in March 2017, and the report became available in June 2017

  8. L'Anse Warden Electric Company Boiler Number One Emission Test Report – December 2016

    Science.gov (United States)

    L’Anse Warden Electric Company (LWEC) submitted results from an emission test on the Boiler No. 1 stack. Stack air emission testing was conducted in December 2016, and the report became available in January 2017

  9. L'Anse Warden Electric Company Boiler Number One Emission Test Report – July 2016

    Science.gov (United States)

    L’Anse Warden Electric Company (LWEC) submitted results from an emission test on the Boiler No. 1 stack. Stack air emission testing was conducted in July 2016, and the report became available in August 2016.

  10. 77 FR 16077 - License Amendment Request From Westinghouse Electric Company, LLC, Hematite Decommissioning Project

    Science.gov (United States)

    2012-03-19

    ... From the Federal Register Online via the Government Publishing Office ] NUCLEAR REGULATORY COMMISSION License Amendment Request From Westinghouse Electric Company, LLC, Hematite Decommissioning Project AGENCY: Nuclear Regulatory Commission. ACTION: License amendment request; opportunity to provide...

  11. NPDES Permit for Potomac Electric Power Company (PEPCO) Benning Generating Station

    Science.gov (United States)

    Under National Pollutant Discharge Elimination System permit number DC0000094, the Potomac Electric Power Company (PEPCO) Benning Generating Station is authorized to discharge from from a facility to receiving waters named Anacostia River.

  12. 77 FR 25162 - Golden Spread Electric Cooperative, Inc. v. Southwestern Public Service Company; Notice of Complaint

    Science.gov (United States)

    2012-04-27

    ... Public Service Company (Respondent or SPS) alleges that the formula rate of Replacement Power Sales... Federal Energy Regulatory Commission Golden Spread Electric Cooperative, Inc. v. Southwestern Public Service Company; Notice of Complaint Take notice that on April 20, 2012, pursuant to sections 201, 206...

  13. States of Cybersecurity: Electricity Distribution System Discussions

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Ivonne [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ingram, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Martin, Maurice [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-03-16

    State and local entities that oversee the reliable, affordable provision of electricity are faced with growing and evolving threats from cybersecurity risks to our nation's electricity distribution system. All-hazards system resilience is a shared responsibility among electric utilities and their regulators or policy-setting boards of directors. Cybersecurity presents new challenges and should be a focus for states, local governments, and Native American tribes that are developing energy-assurance plans to protect critical infrastructure. This research sought to investigate the implementation of governance and policy at the distribution utility level that facilitates cybersecurity preparedness to inform the U.S. Department of Energy (DOE), Office of Energy Policy and Systems Analysis; states; local governments; and other stakeholders on the challenges, gaps, and opportunities that may exist for future analysis. The need is urgent to identify the challenges and inconsistencies in how cybersecurity practices are being applied across the United States to inform the development of best practices, mitigations, and future research and development investments in securing the electricity infrastructure. By examining the current practices and applications of cybersecurity preparedness, this report seeks to identify the challenges and persistent gaps between policy and execution and reflect the underlying motivations of distinct utility structures as they play out at the local level. This study aims to create an initial baseline of cybersecurity preparedness within the distribution electricity sector. The focus of this study is on distribution utilities not bound by the cybersecurity guidelines of the North American Electric Reliability Corporation (NERC) to examine the range of mechanisms taken by state regulators, city councils that own municipal utilities, and boards of directors of rural cooperatives.

  14. Design of investment management optimization system for power grid companies under new electricity reform

    Science.gov (United States)

    Yang, Chunhui; Su, Zhixiong; Wang, Xin; Liu, Yang; Qi, Yongwei

    2017-03-01

    The new normalization of the economic situation and the implementation of a new round of electric power system reform put forward higher requirements to the daily operation of power grid companies. As an important day-to-day operation of power grid companies, investment management is directly related to the promotion of the company's operating efficiency and management level. In this context, the establishment of power grid company investment management optimization system will help to improve the level of investment management and control the company, which is of great significance for power gird companies to adapt to market environment changing as soon as possible and meet the policy environment requirements. Therefore, the purpose of this paper is to construct the investment management optimization system of power grid companies, which includes investment management system, investment process control system, investment structure optimization system, and investment project evaluation system and investment management information platform support system.

  15. Increased Observability in Electric Distribution Grids

    DEFF Research Database (Denmark)

    Prostejovsky, Alexander Maria

    will likely remain the Transmission System Operator (TSO)’s responsibility, DSOs play a major role due to their local awareness. The presented LFC approach consequently uses direct state observations to determine area imbalances, and actively involves primary devices in frequency control to achieve tuning......This thesis addresses supervision and control of horizontally integrated electric power systems, in which Distribution System Operators (DSOs) assume an active role. Focus lies on the technical possibilities emerging from the expanding Information and Communication Technology (ICT) and monitoring...... infrastructure in distribution grids. Strong emphasis is placed on experimental verifications of the investigated concepts wherever applicable. Electric grids are changing, and so are the roles of system operators. The interest in sustainable energy and the rapidly increasing number of Distributed Energy...

  16. State Electricity Regulatory Policy and Distributed Resources: Distributed Resources and Electric System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Cowart, R.; Harrington, C.; Moskovitz, D.; Shirley, W.; Weston, F.; Sedano, R.

    2002-10-01

    Designing and implementing credit-based pilot programs for distributed resources distribution is a low-cost, low-risk opportunity to find out how these resources can help defer or avoid costly electric power system (utility grid) distribution upgrades. This report describes implementation options for deaveraged distribution credits and distributed resource development zones. Developing workable programs implementing these policies can dramatically increase the deployment of distributed resources in ways that benefit distributed resource vendors, users, and distribution utilities. This report is one in the State Electricity Regulatory Policy and Distributed Resources series developed under contract to NREL (see Annual Technical Status Report of the Regulatory Assistance Project: September 2000-September 2001, NREL/SR-560-32733). Other titles in this series are: (1) Accommodating Distributed Resources in Wholesale Markets, NREL/SR-560-32497; (2) Distributed Resources and Electric System Re liability, NREL/SR-560-32498; (3) Distribution System Cost Methodologies for Distributed Generation, NREL/SR-560-32500; (4) Distribution System Cost Methodologies for Distributed Generation Appendices, NREL/SR-560-32501.

  17. Distributed Generation of Electricity and its Environmental Impacts

    Science.gov (United States)

    When connected to the electric utility’s lower voltage distribution lines, distributed generation can help support delivery of clean, reliable power to additional customers and reduce electricity losses along transmission and distribution lines.

  18. Electric field distribution in irradiated silicon detectors

    CERN Document Server

    Castaldini, A; Polenta, L; Nava, F; Canali, C

    2002-01-01

    Particle irradiation causes dramatic changes in bulk properties of p sup + -n-n sup + silicon structures operating as particle detectors. Several attempts to model and justify such variations have been proposed in the last few years. The main unsolved problem remains in the determination of the electric field and depletion layer distributions as key-parameters to estimate the collection efficiency of the detector. By using optical beam induced current (OBIC) and surface potential (SP) measurements we determined the behavior of the electric field and confirmed the existence of a double-junction structure appearing after irradiation.

  19. Electric field distribution in irradiated silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Castaldini, A.; Cavallini, A. E-mail: anna.cavallini@bo.infn.it; Polenta, L.; Nava, F.; Canali, C

    2002-01-11

    Particle irradiation causes dramatic changes in bulk properties of p{sup +}-n-n{sup +} silicon structures operating as particle detectors. Several attempts to model and justify such variations have been proposed in the last few years. The main unsolved problem remains in the determination of the electric field and depletion layer distributions as key-parameters to estimate the collection efficiency of the detector. By using optical beam induced current (OBIC) and surface potential (SP) measurements we determined the behavior of the electric field and confirmed the existence of a double-junction structure appearing after irradiation.

  20. Switching in electrical transmission and distribution systems

    CERN Document Server

    Smeets, René; Kapetanovic, Mirsad; Peelo, David F; Janssen, Anton

    2014-01-01

    Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage. The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests. Other highlights include: up to date commentary on new develo

  1. 78 FR 37212 - Portland General Electric Company; Notice of Application Accepted for Filing, Soliciting Motions...

    Science.gov (United States)

    2013-06-20

    ... General Electric (licensee) proposes to construct, operate and maintain small turbine facilities at four... turbine and induction generator utilizing North Fork fishway attraction flows. The total capacity of the... Energy Regulatory Commission Portland General Electric Company; Notice of Application Accepted for Filing...

  2. 75 FR 77570 - Airworthiness Directives; General Electric Company CF6 Series Turbofan Engines

    Science.gov (United States)

    2010-12-13

    ...) for General Electric (GE) CF6-45/-50 series and CF6-80A series turbofan engines with certain part... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company CF6 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of...

  3. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    Science.gov (United States)

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2006-12-12

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  4. Simulation of Hawaiian Electric Companies Feeder Operations with Advanced Inverters and Analysis of Annual Photovoltaic Energy Curtailment

    Energy Technology Data Exchange (ETDEWEB)

    Giraldez Miner, Julieta I [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Nagarajan, Adarsh [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gotseff, Peter [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Krishnan, Venkat K [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hoke, Anderson F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ueda, Reid [Hawaiian Electric Company; Shindo, Jon [Hawaiian Electric Company; Asano, Marc [Hawaiian Electric Company; Ifuku, Earle [Hawaiian Electric Company

    2017-07-26

    The Hawaiian Electric Companies achieved a consolidated Renewable Portfolio Standard (RPS) of approximately 26% at the end of 2016. This significant RPS performance was achieved using various renewable energy sources - biomass, geothermal, solar photovoltaic (PV) systems, hydro, wind, and biofuels - and customer-sited, grid-connected technologies (primarily private rooftop solar PV systems). The Hawaiian Electric Companies are preparing grid-modernization plans for the island grids. The plans outline specific near-term actions to accelerate the achievement of Hawai'i's 100% RPS by 2045. A key element of the Companies' grid-modernization strategy is to utilize new technologies - including storage and PV systems with grid-supportive inverters - that will help to more than triple the amount of private rooftop solar PV systems. The Hawaiian Electric Companies collaborated with the Smart Inverter Technical Working Group Hawai'i (SITWG) to partner with the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to research the implementation of advanced inverter grid support functions (GSF). Together with the technical guidance from the Companies's planning engineers and stakeholder input from the SITWG members, NREL proposed a scope of work that explored different modes of voltage-regulation GSF to better understand the trade-offs of the grid benefits and curtailment impacts from the activation of selected advanced inverter grid support functions. The simulation results presented in this report examine the effectiveness in regulating voltage as well as the impact to the utility and the customers of various inverter-based grid support functions on two Hawaiian Electric distribution substations.

  5. DETERMINANTS AFFECTING THE SUCCESS OF DISTRIBUTION GRID PROJECTS IN BINH THUAN POWER COMPANY, VIETNAM

    OpenAIRE

    Pham Van Tai* & Le Duc Thu

    2017-01-01

    The research identified the critical factors affecting the success of the distribution grid project in Binh Thuan Power Company, clarify the mutual relationship between the critical factors affecting the success of the distribution grid project in Binh Thuan Power Company and recommended and rated the solution to enhance the success of the distribution grid project in Binh Thuan Power Company. The research had found fours critical factors: External factors of project, Controlling and coordina...

  6. Electrical power systems for distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, T.A.; Huval, S.J. [Stewart & Stevenson Services, Inc., Houston, TX (United States)

    1996-12-31

    {open_quotes}Distributed Generation{close_quotes} has become the {open_quotes}buzz{close_quotes} word of an electric utility industry facing deregulation. Many industrial facilities utilize equipment in distributed installations to serve the needs of a thermal host through the capture of exhaust energy in a heat recovery steam generator. The electrical power generated is then sold as a {open_quotes}side benefit{close_quotes} to the cost-effective supply of high quality thermal energy. Distributed generation is desirable for many different reasons, each with unique characteristics of the product. Many years of experience in the distributed generation market has helped Stewart & Stevenson to define a range of product features that are crucial to most any application. The following paper will highlight a few of these applications. The paper will also examine the range of products currently available and in development. Finally, we will survey the additional services offered by Stewart & Stevenson to meet the needs of a rapidly changing power generation industry.

  7. 26 CFR 1.1247-1 - Election by foreign investment companies to distribute income currently.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Election by foreign investment companies to... Gains and Losses § 1.1247-1 Election by foreign investment companies to distribute income currently. (a) Election by foreign investment company—(1) In general. If a registered foreign investment company (as...

  8. Effects of the financial crisis on the wealth distribution of Korea's companies

    Science.gov (United States)

    Lim, Kyuseong; Kim, Soo Yong; Swanson, Todd; Kim, Jooyun

    2017-02-01

    We investigated the distribution functions of Korea's top-rated companies during two financial crises. A power-law scaling for rank distribution, as well as cumulative probability distribution, was found and observed as a general pattern. Similar distributions can be shown in other studies of wealth and income distributions. In our study, the Pareto exponents designating the distribution differed before and after the crisis. The companies covered in this research are divided into two subgroups during a period when the subprime mortgage crisis occurred. Various industrial sectors of Korea's companies were found to respond differently during the two financial crises, especially the construction sector, financial sectors, and insurance groups.

  9. Electric Potential Distribution in an Electrochemical Cell

    Science.gov (United States)

    Millet, Pierre

    1996-10-01

    Many students learning electrochemistry do not understand how current flows from one electrode to the other in an electrochemical cell. This is generally because interfacial phenomena and ionic conductivity in the electrolytic solution tend to be treated separately by chemistry teachers. An easy way to improve students' understanding of "how it works" is to compute the two dimensional electric potential distribution in the cell and to make a gravitational analogy. Current flows from one electrode to the other just like a ball would do in a gravitational field.

  10. A Project Strategic Index proposal for portfolio selection in electrical company based on the Analytic Network Process

    Energy Technology Data Exchange (ETDEWEB)

    Smith-Perera, Aida [Universidad Metropolitana de Caracas, Departamento de Gestion Tecnologica, Caracas 1071, Edo Miranda (Venezuela); Garcia-Melon, Monica; Poveda-Bautista, Rocio; Pastor-Ferrando, Juan-Pascual [Universidad Politecnica de Valencia, Departamento de Proyectos de Ingenieria, Camino de vera s/n 46022 Valencia (Spain)

    2010-08-15

    In this paper a new approach to prioritize project portfolio in an efficient and reliable way is presented. It is based on strategic objectives of the company and multicriteria decision methods. The paper introduces a rigorous method with acceptable complexity which seeks to assist managers of a big Electrical Company of Venezuela to distribute the annual budget among the possible improvement actions to be conducted on the electrical network of Caracas. A total of 15 network improvement actions grouped into three clusters according to the strategic objectives of the company have been analyzed using the Project Strategic Index (PSI) proposed. The approach combines the use of the Analytic Network Process (ANP) method with the information obtained from the experts during the decision-making process. The ANP method allows the aggregation of the experts' judgments on each of the indicators used into one Project Strategic Index. In addition, ANP is based on utility ratio functions which are the most appropriate for the analysis of uncertain data, like experts' estimations. Finally, unlike the other multicriteria techniques, ANP allows the decision problem to be modelled using the relationships among dependent criteria. The participating experts coincided in the appreciation that the method proposed in this paper is useful and an improvement from traditional budget distribution techniques. They find the results obtained coherent, the process seems sufficiently rigorous and precise, and the use of resources is significantly less than in other methods. (author)

  11. Exploring Distributed Energy Alternatives to Electrical Distribution Grid Expansion in Souhern California Edison Service Territory

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, Therese K [ORNL; Kingston, Tim [Gas Technology Institute

    2005-12-01

    Distributed energy (DE) technologies have received much attention for the energy savings and electric power reliability assurances that may be achieved by their widespread adoption. Fueling the attention have been the desires to globally reduce greenhouse gas emissions and concern about easing power transmission and distribution system capacity limitations and congestion. However, these benefits may come at a cost to the electric utility companies in terms of lost revenue and concerns with interconnection on the distribution system. This study assesses the costs and benefits of DE to both consumers and distribution utilities and expands upon a precursory study done with Detroit Edison (DTE)1, by evaluating the combined impact of DE, energy-efficiency, photovoltaics (a use of solar energy), and demand response that will shape the grid of the future. This study was funded by the U.S. Department of Energy (DOE), Gas Research Institute (GRI), American Electric Power (AEP), and Gas Technology Institute's (GTI) Distributed Energy Collaborative Program (DECP). It focuses on two real Southern California Edison (SCE) circuits, a 13 MW suburban circuit fictitiously named Justice on the Lincoln substation, and an 8 MW rural circuit fictitiously named Prosper on the Washington Substation. The primary objectives of the study were threefold: (1) Evaluate the potential for using advanced energy technologies, including DE, energy-efficiency (EE), demand response, electricity storage, and photovoltaics (PV), to reshape electric load curves by reducing peak demand, for real circuits. (2) Investigate the potential impact on guiding technology deployment and managing operation in a way that benefits both utilities and their customers by: (a) Improving grid load factor for utilities; (b) Reducing energy costs for customers; and (c) Optimizing electric demand growth. (3) Demonstrate benefits by reporting on a recently installed advanced energy system at a utility customer site

  12. Multiple criteria decision making techniques applied to electricity distribution system planning

    Energy Technology Data Exchange (ETDEWEB)

    Espie, P.; Ault, G.W.; Burt, G.M.; McDonald, J.R. [University of Strathclyde (United Kingdom). Inst. for Energy and the Environment

    2003-09-01

    An approach is described for electricity distribution system planning that allows issues such as load growth, distributed generation, asset management, quality of supply and environmental issues to be considered. In contrast to traditional optimisation approaches which typically assess alternative planning solution by finding the solution with the minimum total cost, the proposed methodology utilises a number of discrete evaluation criteria within a multiple criteria decision making (MCDM) environment to examine and assess the trade-offs between alternative solutions. To demonstrate the proposed methodology a worked example is performed on a test distribution network that forms part of an existing distribution network in one UK distribution company area. The results confirm the suitability of MCDM techniques to the distribution planning problem and highlight how evaluating all planning problems simultaneously can provide substantial benefits to a distribution company. (Author)

  13. 78 FR 6313 - Pacific Gas and Electric Company; Notice of Application Accepted for Filing, Soliciting Comments...

    Science.gov (United States)

    2013-01-30

    ... Energy Regulatory Commission Pacific Gas and Electric Company; Notice of Application Accepted for Filing.... (415) 973-4466, Email: [email protected] ; or Annette Faraglia, Esq., Law Department, Pacific Gas and... application has been filed with the Commission and is available for public inspection: a. Types of Application...

  14. 78 FR 46332 - Golden Spread Electric Cooperative, Inc. v. Southwestern Public Service Company; Notice of Complaint

    Science.gov (United States)

    2013-07-31

    ... Energy Regulatory Commission Golden Spread Electric Cooperative, Inc. v. Southwestern Public Service.... (Golden Spread or Complainant) filed a formal complaint against Southwestern Public Service Company (SPS... Energy Open Access Tariff applicable to pricing of transmission service over the facilities of SPS...

  15. 75 FR 10838 - Pacific Gas and Electric Company; Diablo Canyon Power Plant; Exemption

    Science.gov (United States)

    2010-03-09

    ... COMMISSION Pacific Gas and Electric Company; Diablo Canyon Power Plant; Exemption 1.0 Background Pacific Gas... DPR-82, which authorize operation of the Diablo Canyon Power Plant, Units Nos. 1 and 2 (DCPP). The... operating nuclear power plants, but noted that the Commission's regulations provide mechanisms for...

  16. 77 FR 36302 - Yankee Atomic Electric Company, Yankee Nuclear Power Station, Confirmatory Order Modifying...

    Science.gov (United States)

    2012-06-18

    ... classes of Yankee Atomic Electric Company stock. V In accordance with 10 CFR 2.202, any person adversely... Meta System Help Desk will not be able to offer assistance in using unlisted software. If a participant... assistance by contacting the NRC Meta System Help Desk through the ``Contact Us'' link located on the NRC Web...

  17. 78 FR 14786 - Union Electric Company (dba Ameren Missouri); Notice of Availability of Draft Environmental...

    Science.gov (United States)

    2013-03-07

    ... and contact information at the end of your comments. For assistance, please contact FERC Online... Energy Regulatory Commission Union Electric Company (dba Ameren Missouri); Notice of Availability of....gov using the ``eLibrary'' link. Enter the docket number, excluding the last three digits, in the...

  18. 76 FR 77994 - Pacific Gas and Electric Company; Notice of Availability of Environmental Assessment

    Science.gov (United States)

    2011-12-15

    ... and contact information at the end of your comments. Please contact Mary Greene by telephone at (202... Energy Regulatory Commission Pacific Gas and Electric Company; Notice of Availability of Environmental...'' link. Enter the docket number excluding the last three digits in the docket number field to access the...

  19. 78 FR 45984 - Yankee Atomic Electric Company, Yankee Nuclear Power Station

    Science.gov (United States)

    2013-07-30

    ... COMMISSION Yankee Atomic Electric Company, Yankee Nuclear Power Station AGENCY: Nuclear Regulatory Commission... on the site of any nuclear power reactor. In its Statement of Considerations (SOC) for the Final Rule... the site of a nuclear power reactor licensed for operation by the Commission, the emergency plan...

  20. 77 FR 10950 - Airworthiness Directives; General Electric Company (GE) Turbofan Engines

    Science.gov (United States)

    2012-02-24

    ...-27-AD; Amendment 39-16961; AD 2012-04-05] RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule... engines. That AD currently requires installing software version 8.2.Q1 to the engine electronic control...

  1. 77 FR 12444 - Airworthiness Directives; General Electric Company (GE) Turbofan Engines

    Science.gov (United States)

    2012-03-01

    ...-09-AD; Amendment 39-16954; AD 2012-03-12] RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for all GE CF6-80C2 model turbofan engines...

  2. 76 FR 68634 - Airworthiness Directives; General Electric Company (GE) CF6 Turbofan Engines

    Science.gov (United States)

    2011-11-07

    ...-04] RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) CF6 Turbofan Engines AGENCY... airworthiness directive (AD) for the engines identified above. That AD currently requires initial and repetitive visual inspections of the forward engine mount assembly side links for cracks, stripping and reapplying...

  3. 76 FR 19334 - Pacific Gas and Electric Company; Notice of Application Accepted for Filing, Soliciting Motions...

    Science.gov (United States)

    2011-04-07

    ... does not plan any changes to the operation or maintenance of the transmission line. m. A copy of the...: Subsequent License--Transmission Line Only. b. Project No.: P-2479-011. c. Date filed: February 22, 2011. d. Applicant: Pacific Gas and Electric Company. e. Name of Project: French Meadows Transmission Line Project. f...

  4. 76 FR 37105 - Pacific Gas and Electric Company; Notice of Application Accepted for Filing, Soliciting Motions...

    Science.gov (United States)

    2011-06-24

    ... changes to the operation or maintenance of the transmission line. m. A copy of the application is...: Subsequent License--Transmission Line Only. b. Project No.: P-2784-004. c. Date filed: April 18, 2011. d. Applicant: Pacific Gas and Electric Company. e. Name of Project: Rollins Transmission Line Project. f...

  5. 77 FR 11171 - License Renewal Application for Callaway Plant, Unit 1, Union Electric Company

    Science.gov (United States)

    2012-02-24

    ... Regulatory Commission. ACTION: Intent to prepare environmental impact statement and conduct scoping process. SUMMARY: Union Electric Company, a subsidiary of Ameren Corporation and doing business as Ameren Missouri... environmental impact statement (EIS) related to the review of the license renewal application and to provide the...

  6. Tampa Electric Company, Polk Power Station Unit No. 1, preliminary public design report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-06-01

    This preliminary Public Design Report (PDR) provides design information about Tampa Electric Company`s Polk Power Station Unit No. 1, which will demonstrate in a commercial 250 MW unit the benefits of the integration of oxygen-blown, entrained-flow coal gasification with advanced combined cycle technology. This project is partially funded by the US Department of Energy (DOE) under Round III of its Clean Coal Technology (CCT) Program under the provisions of Cooperative Agreement between DOE and Tampa Electric Company, novated on March 5,1992. The project is highlighted by the inclusion of a new hot gas cleanup system. DOE`s project management is based at its Morgantown Energy Technology Center (METC) in West Virginia. This report is preliminary, and the information contained herein is subject to revision. Definitive information will be available in the final PDR, which will be published at the completion of detailed engineering.

  7. Life cycle assessment of the Danish electricity distribution network

    DEFF Research Database (Denmark)

    Turconi, Roberto; Simonsen, Christian G.; Byriel, Inger P.

    2014-01-01

    and overhead) and 0.4 kV (copper and aluminum) were modeled. Results and discussion Electricity transmission and distribution provided nonnegligible impacts, related mainly to power losses. Impacts from electricity distribution were larger than those from transmission because of higher losses and higher......Purpose This article provides life cycle inventory data for electricity distribution networks and a life cycle assessment (LCA) of the Danish transmission and distribution networks. The aim of the study was to evaluate the potential importance of environmental impacts associated with distribution......, in current and future electricity systems. Methods The functional unit was delivery of 1 kWh of electricity in Denmark. The focus of the assessment was distribution of electricity, and the related impacts were compared to the generation and transmission of electricity, in order to evaluate the importance...

  8. 76 FR 11522 - South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority...

    Science.gov (United States)

    2011-03-02

    ... COMMISSION South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority... Carolina Electric and Gas Company (SCE&G) acting as itself and agent for the South Carolina Public Service... application is available for public inspection at the Commission's Public Document Room (PDR), located at One...

  9. 76 FR 14436 - South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority...

    Science.gov (United States)

    2011-03-16

    ... COMMISSION South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority... Carolina Electric and Gas Company (SCE&G) acting as itself and agent for the South Carolina Public Service... application is available for public inspection at the Commission's Public Document Room (PDR), located at One...

  10. 76 FR 12998 - South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority...

    Science.gov (United States)

    2011-03-09

    ... COMMISSION South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority... Carolina Electric and Gas Company (SCE&G) acting as itself and agent for the South Carolina Public Service... application is available for public inspection at the Commission's Public Document Room (PDR), located at One...

  11. 76 FR 16456 - South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority...

    Science.gov (United States)

    2011-03-23

    ... COMMISSION South Carolina Electric and Gas Company (SCE&G) and the South Carolina Public Service Authority... Carolina Electric and Gas Company (SCE&G) acting as itself and agent for the South Carolina Public Service... application is available for public inspection at the Commission's Public Document Room (PDR), located at One...

  12. 76 FR 76153 - Allco Renewable Energy Limited v. Massachusetts Electric Company d/b/a National Grid; Notice of...

    Science.gov (United States)

    2011-12-06

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Allco Renewable Energy Limited v. Massachusetts Electric Company d/b/a... Renewable Energy Limited filed a formal complaint against Massachusetts Electric Company (National Grid...

  13. 77 FR 12274 - Pacific Gas and Electric Company; Notice of Application Tendered for Filing With the Commission...

    Science.gov (United States)

    2012-02-29

    ... steel building housing a 3.4-megawatt (MW) turbine/generator unit and a vertical Kaplan-type four-blade... Energy Regulatory Commission Pacific Gas and Electric Company; Notice of Application Tendered for Filing...-020. c. Date Filed: February 8, 2012. d. Applicant: Pacific Gas and Electric Company (PG&E). e. Name...

  14. 76 FR 292 - Airworthiness Directives; General Electric Company CF6-45 and CF6-50 Series Turbofan Engines

    Science.gov (United States)

    2011-01-04

    ... directive (AD) that applies to General Electric Company (GE) CF6-45 and CF6-50 series turbofan engines. The... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company CF6-45 and CF6-50 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...

  15. 75 FR 12661 - Airworthiness Directives; General Electric Company CF6-45 and CF6-50 Series Turbofan Engines

    Science.gov (United States)

    2010-03-17

    ...) for General Electric Company (GE) CF6-45 and CF6-50 series turbofan engines with certain low-pressure...-05-AD; Amendment 39-16240; AD 2010-06-15] RIN 2120-AA64 Airworthiness Directives; General Electric Company CF6-45 and CF6-50 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...

  16. 75 FR 32649 - Airworthiness Directives; General Electric Company CF6-45 and CF6-50 Series Turbofan Engines

    Science.gov (United States)

    2010-06-09

    ... Electric Company (GE) CF6-45 and CF6-50 series turbofan engines with certain low-pressure turbine (LPT...; AD 2010-12-10] RIN 2120-AA64 Airworthiness Directives; General Electric Company CF6-45 and CF6-50 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule; request...

  17. 75 FR 9449 - Virginia Electric and Power Company; North Anna Power Station, Unit Nos. 1 and 2

    Science.gov (United States)

    2010-03-02

    ... North Anna Power Station, Unit Nos. 1 and 2 (NAPS). The licenses provide, among other things, that the... COMMISSION [Docket Nos. 50-338 and 50-339; NRC-2010-0026 Virginia Electric and Power Company; North Anna Power Station, Unit Nos. 1 and 2 1.0 Background The Virginia Electric and Power Company, (the licensee...

  18. 75 FR 4591 - Virginia Electric and Power Company; North Anna Power Station, Unit Nos. 1 and 2; Environmental...

    Science.gov (United States)

    2010-01-28

    ...-7, issued to Virginia Electric and Power Company, (the licensee), for operation of the North Anna Power Station, Unit Nos. 1 and 2 (NAPS). In accordance with 10 CFR 51.21, ``Criteria for and... COMMISSION Virginia Electric and Power Company; North Anna Power Station, Unit Nos. 1 and 2; Environmental...

  19. Observations of Distribution Company Decisive Action Operations at the NTC

    Science.gov (United States)

    2016-02-26

    repair parts) in order to assist in generating com- bat power, managing commodities, and reporting commodity statuses. Many companies do an excellent...job of maximizing road networks within the brigade support area in order to establish water resupply points, retail fuel points, bulk water storage

  20. [Tampa Electric Company IGCC project]. Final public design report; Technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This final Public Design Report (PDR) provides completed design information about Tampa Electric Company`s Polk Power Station Unit No. 1, which will demonstrate in a commercial 250 MW unit the operating parameters and benefits of the integration of oxygen-blown, entrained-flow coal gasification with advanced combined cycle technology. Pending development of technically and commercially viable sorbent for the Hot Gas Cleanup System, the HGCU also is demonstrated. The report is organized under the following sections: design basis description; plant descriptions; plant systems; project costs and schedule; heat and material balances; general arrangement drawings; equipment list; and miscellaneous drawings.

  1. Evaluation of energy saving tasks performed by the energy transmission and distribution companies; Denmark; Evaluering af energiselskabernes energibespareaktiviteter

    Energy Technology Data Exchange (ETDEWEB)

    Togeby, M. (Ea Energianalyse A/S, Copenhagen (Denmark))

    2012-05-15

    The evaluation is described in the Agreement of 20 November 2009 between the Danish Climate and Energy Minister and the distribution companies for electricity, natural gas, district heating and oil about the companies' future energy conservation efforts. The evaluation was conducted to provide recommendations for adjusting the system. The results of the evaluation show that energy companies and utilities meet the overall savings obligation. In 2011, 2,098 GWh savings are recorded, which is more than the obligation. The evaluation shows that the net effect is about 760 GWh (36%). When looking at types of energy companies, then the oil companies' activities generally have a low net effect and additionally is assessed to be low in relation to the district heating companies' renovation of the district heating network. The greatest additionally exists among large savings in the industry. The means that energy companies use to achieve savings obligations are significantly different today than a few years ago. Today there are grants for more than 85% of registered savings. Before 2006 primarily information and advice was used. Thus an estimated 400 million DKK annually is used for grants. Socio-economics is positive for the part of the effort that is aimed at businesses. The socio-economic value of the savings is calculated to be twice as large as the total cost when you only look at the industry. The system can thus be readily seen as a useful instrument to promote energy conservation in industry. For households, it is estimated that the net effect is 20% of the reported savings, while for industry the net effect is estimated to be 45%. Also, for renovations of the heat distribution networks the net effect is estimated to be low. (LN)

  2. Wireless distributed functional electrical stimulation system

    Directory of Open Access Journals (Sweden)

    Jovičić Nenad S

    2012-08-01

    Full Text Available Abstract Background The control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement. Methods The new system comprises a set of miniature battery-powered devices with stimulating and sensing functionality mounted on the body of the subject. The devices communicate wirelessly with one coordinator device, which is connected to a host computer. The control algorithm runs on the computer in open- or closed-loop form. A prototype of the system was designed using commercial, off-the-shelf components. The propagation characteristics of electromagnetic waves and the distributed nature of the system were considered during the development of a two-hop routing protocol, which was implemented in the prototype’s software. Results The outcomes of this research include a novel system architecture and routing protocol and a functional prototype based on commercial, off-the-shelf components. A proof-of-concept study was performed on a hemiplegic subject with paresis of the right arm. The subject was tasked with generating a fully functional palmar grasp (closing of the fingers. One node was used to provide this movement, while a second node controlled the activation of extensor muscles to eliminate undesired wrist flexion. The system was tested with the open- and closed-loop control algorithms. Conclusions The system fulfilled technical and application requirements. The novel communication protocol enabled reliable real-time use of the system in both closed- and open-loop forms. The testing on a patient showed that the multi-node system could operate effectively to generate functional movement.

  3. Wireless distributed functional electrical stimulation system.

    Science.gov (United States)

    Jovičić, Nenad S; Saranovac, Lazar V; Popović, Dejan B

    2012-08-09

    The control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement. The new system comprises a set of miniature battery-powered devices with stimulating and sensing functionality mounted on the body of the subject. The devices communicate wirelessly with one coordinator device, which is connected to a host computer. The control algorithm runs on the computer in open- or closed-loop form. A prototype of the system was designed using commercial, off-the-shelf components. The propagation characteristics of electromagnetic waves and the distributed nature of the system were considered during the development of a two-hop routing protocol, which was implemented in the prototype's software. The outcomes of this research include a novel system architecture and routing protocol and a functional prototype based on commercial, off-the-shelf components. A proof-of-concept study was performed on a hemiplegic subject with paresis of the right arm. The subject was tasked with generating a fully functional palmar grasp (closing of the fingers). One node was used to provide this movement, while a second node controlled the activation of extensor muscles to eliminate undesired wrist flexion. The system was tested with the open- and closed-loop control algorithms. The system fulfilled technical and application requirements. The novel communication protocol enabled reliable real-time use of the system in both closed- and open-loop forms. The testing on a patient showed that the multi-node system could operate effectively to generate functional movement.

  4. Internationalization strategy and foreign distribution channels: analysis of the brazilian cosmetics company Natura

    Directory of Open Access Journals (Sweden)

    Silvia Novaes Zilbe

    2010-01-01

    Full Text Available This paper describes the internationalization process of the Brazilian company Natura Cosméticos S.A., whose competitive differential is the development of products based on the biodiversity of Brazilian flora. We specifically focus on the company's different choices of distribution channels in foreign markets. The study is exploratory, relying on content analysis of secondary data. The results indicate that the company's internationalization process has followed the model of the Uppsala school (learning and that the company has maintained the same distribution strategy (direct sales in markets with similar cultures (Latin America, but for the European market (Paris it preferred to establish a physical store because of the cultural differences of that market. The change of the distribution channel model in the European market led the company to develop new organizational competencies.

  5. Workers' Participation and the Distribution of Control as Perceived by Members of Ten German Companies.

    Science.gov (United States)

    Bartolke, Klaus; And Others

    1982-01-01

    A survey of 601 managers and workers in 10 German manufacturing companies studied the implications of workers' participation for the exercise of control. Statistical analysis of data on control over work environments, production organization, personnel, and finance indicated that, in more participative companies, distribution of control is more…

  6. Managing the transition from regulated electric utility to energy marketing company

    Energy Technology Data Exchange (ETDEWEB)

    Krapels, E.N.

    1977-01-01

    Companies that hope to succeed in converging energy service business must plan to trade bundled and unbundled energy commodities in paper as well as physical markets. The winners will be those who realize the immensity and crucial importance of the former. Many traditional electric utilities are spending most of their time defensively on stranded asset issues, and only token amounts of time proactively on how to become a Btu company. The vacuum they are creating is being filled by those companies - Enron, UtiliCorp United, Duke Power, and a few others who have made preparing for the future their core mission rather than a sideshow. Important as the stranded asset issue is - and it is especially critical in nuclear-heavy regions like New England - the author believes that senior executives of all electric utilities must immediately relegate this {open_quotes}work of the past{close_quotes} to second place. It is urgent that they now begin to do what Enron decided to do almost ten years ago: acknowledge that an enormous paradigm shift has taken place in the energy industry and devote all available brainpower to preparing for that change. Electric utilities are on the threshold of an era in which electricity prices will be determined, not only by supply and demand as traditionally understood, but by the supply and demand for electricity in paper markets. In traditional market nomenclature, prices are determined by supply and demand. In paper markets, while the analytical metaphor is identical, the language and dynamics are different: Prices will emerge from the interplay of those who are {open_quotes}short{close_quotes} (i.e., willing to sell in the power futures markets at given prices). Electric utilities must master the dynamics of both markets. No less than their corporate survival is at stake.

  7. Digital combined instrument transformer for automated electric power supply control systems of mining companies

    Science.gov (United States)

    Topolsky, D. V.; Gonenko, T. V.; Khatsevskiy, V. F.

    2017-10-01

    The present paper discusses ways to solve the problem of enhancing operating efficiency of automated electric power supply control systems of mining companies. According to the authors, one of the ways to solve this problem is intellectualization of the electric power supply control system equipment. To enhance efficiency of electric power supply control and electricity metering, it is proposed to use specially designed digital combined instrument current and voltage transformers. This equipment conforms to IEC 61850 international standard and is adapted for integration into the digital substation structure. Tests were performed to check conformity of an experimental prototype of the digital combined instrument current and voltage transformer with IEC 61850 standard. The test results have shown that the considered equipment meets the requirements of the standard.

  8. Technique applied in electrical power distribution for Satellite Launch Vehicle

    Directory of Open Access Journals (Sweden)

    João Maurício Rosário

    2010-09-01

    Full Text Available The Satellite Launch Vehicle electrical network, which is currently being developed in Brazil, is sub-divided for analysis in the following parts: Service Electrical Network, Controlling Electrical Network, Safety Electrical Network and Telemetry Electrical Network. During the pre-launching and launching phases, these electrical networks are associated electrically and mechanically to the structure of the vehicle. In order to succeed in the integration of these electrical networks it is necessary to employ techniques of electrical power distribution, which are proper to Launch Vehicle systems. This work presents the most important techniques to be considered in the characterization of the electrical power supply applied to Launch Vehicle systems. Such techniques are primarily designed to allow the electrical networks, when submitted to the single-phase fault to ground, to be able of keeping the power supply to the loads.

  9. Distribution Locational Marginal Pricing for Optimal Electric Vehicle Charging Management

    DEFF Research Database (Denmark)

    Li, Ruoyang; Wu, Qiuwei; Oren, Shmuel S.

    2013-01-01

    This paper presents an integrated distribution locational marginal pricing (DLMP) method designed to alleviate congestion induced by electric vehicle (EV) loads in future power systems. In the proposed approach, the distribution system operator (DSO) determines distribution locational marginal...... prices (DLMPs) by solving the social welfare optimization of the Electric distribution system which considers EV aggregators as Price takers in the local DSO market and demand price elasticity. Nonlinear optimization has been used to solve the social welfare optimization problem in order to obtain...

  10. Distribution Locational Marginal Pricing for Optimal Electric Vehicle Charging Management

    OpenAIRE

    Li, Ruoyang; Wu, Qiuwei; Shmuel S Oren

    2013-01-01

    This paper presents an integrated distribution locational marginal pricing (DLMP) method designed to alleviate congestion induced by electric vehicle (EV) loads in future power systems. In the proposed approach, the distribution system operator (DSO) determines distribution locational marginal prices (DLMPs) by solving the social welfare optimization of the Electric distribution system which considers EV aggregators as Price takers in the local DSO market and demand price elasticity. Nonlinea...

  11. DISTRIBUTED ELECTRICAL POWER PRODUCTION SYSTEM AND METHOD OF CONTROL THEREOF

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a distributed electrical power production system wherein two or more electrical power units comprise respective sets of power supply attributes. Each set of power supply attributes is associated with a dynamic operating state of a particular electrical power unit....

  12. EDISON - research programme on electricity distribution automation 1993-1997. Interim report 1995

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M. [ed.] [VTT Energy, Espoo (Finland). Energy Systems

    1996-12-31

    The report comprises a summary of the results of the first three years of the research programme EDISON on distribution automation in Finnish electrical utilities. The five year research programme (1993-1997) is conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of funding is from the Technology Development Centre (Tekes) and from manufacturing companies. The goal of the research programme is to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer automation functions. In addition, the techniques for demand side management are developed and integrated into the automation scheme. The final aim is to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of thirteen projects are now given. These results should be considered intermediate, since most projects will be continued in 1996. (orig.)

  13. Method of imaging the electrical conductivity distribution of a subsurface

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Timothy C.

    2017-09-26

    A method of imaging electrical conductivity distribution of a subsurface containing metallic structures with known locations and dimensions is disclosed. Current is injected into the subsurface to measure electrical potentials using multiple sets of electrodes, thus generating electrical resistivity tomography measurements. A numeric code is applied to simulate the measured potentials in the presence of the metallic structures. An inversion code is applied that utilizes the electrical resistivity tomography measurements and the simulated measured potentials to image the subsurface electrical conductivity distribution and remove effects of the subsurface metallic structures with known locations and dimensions.

  14. Impacts of Electric Vehicle Loads on Power Distribution Systems

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2010-01-01

    Electric vehicles (EVs) are the most promising alternative to replace a significant amount of gasoline vehicles to provide cleaner, CO2 free and climate friendly transportation. On integrating more electric vehicles, the electric utilities must analyse the related impacts on the electricity system...... operation. This paper investigates the effects on the key power distribution system parameters like voltages, line drops, system losses etc. by integrating electric vehicles in the range of 0-50% of the cars with different charging capacities. The dump as well as smart charging modes of electric vehicles...... is applied in this analysis. A typical Danish primary power distribution system is used as a test case for the studies. From the simulation results, not more than 10% of electric vehicles could be integrated in the test system for the dump charging mode. About 40% of electric vehicle loads could...

  15. Electric power distribution, automation, protection, and control

    CERN Document Server

    Momoh, James A

    2007-01-01

    * Each Chapter Provides an Introduction, Illustrative Examples, and a SummaryIntroduction to Distribution Automation Systems Historical Background Distribution System Topology and Structure Distribution Automation (DA) and Control Computational Techniques for Distribution Systems Complex Power Concepts Balanced Voltage to Neutral-Connected System Power Relationship for f Y-?-Connected System Per-Unit System Calculation of Power Losses Voltage Regulation Techniques Voltage-Sag Analysis and Calculation Equipment Modeling Components Modeling Distribution System Line Model Distribution Power Flo

  16. Development of advanced methods for planning electric energy distribution systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Goenen, T.; Foote, B.L.; Thompson, J.C.; Fagan, J.E.

    1979-10-01

    An extensive search was made for the identification and collection of reports published in the open literature which describes distribution planning methods and techniques. In addition, a questionnaire has been prepared and sent to a large number of electric power utility companies. A large number of these companies were visited and/or their distribution planners interviewed for the identification and description of distribution system planning methods and techniques used by these electric power utility companies and other commercial entities. Distribution systems planning models were reviewed and a set of new mixed-integer programming models were developed for the optimal expansion of the distribution systems. The models help the planner to select: (1) optimum substation locations; (2) optimum substation expansions; (3) optimum substation transformer sizes; (4) optimum load transfers between substations; (5) optimum feeder routes and sizes subject to a set of specified constraints. The models permit following existing right-of-ways and avoid areas where feeders and substations cannot be constructed. The results of computer runs were analyzed for adequacy in serving projected loads within regulation limits for both normal and emergency operation.

  17. 78 FR 49551 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-08-14

    ... Company, ] Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, and the City of Dalton... authorized by law; B. The exemption presents no undue risk to public health and safety; C. The exemption is...

  18. Secure data networks for electrical distribution applications

    OpenAIRE

    Laverty, David M.; O'Raw, John B.; Li, Kang; Morrow, D. John

    2015-01-01

    Smart Grids are characterized by the application of information communication technology (ICT) to solve electrical energy challenges. Electric power networks span large geographical areas, thus a necessary component of many Smart Grid applications is a wide area network (WAN). For the Smart Grid to be successful, utilities must be confident that the communications infrastructure is secure. This paper describes how a WAN can be deployed using WiMAX radio technology to provide high bandwidth co...

  19. 26 CFR 1.951-2 - Coordination of subpart F with election of a foreign investment company to distribute income.

    Science.gov (United States)

    2010-04-01

    ... foreign investment company to distribute income. 1.951-2 Section 1.951-2 Internal Revenue INTERNAL REVENUE... Corporations § 1.951-2 Coordination of subpart F with election of a foreign investment company to distribute... meaning of section 1247(c)) of a foreign investment company with respect to which an election under...

  20. Electricity End Uses, Energy Efficiency, and Distributed Energy Resources Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Morrow, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Deason, Jeff [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leventis, Greg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Smith, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leow, Woei Ling [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Levin, Todd [Argonne National Lab. (ANL), Argonne, IL (United States); Plotkin, Steven [Argonne National Lab. (ANL), Argonne, IL (United States); Zhou, Yan [Oak Ridge Inst. for Science and Education (ORISE), Oak Ridge, TN (United States)

    2017-01-01

    This report was developed by a team of analysts at Lawrence Berkeley National Laboratory, with Argonne National Laboratory contributing the transportation section, and is a DOE EPSA product and part of a series of “baseline” reports intended to inform the second installment of the Quadrennial Energy Review (QER 1.2). QER 1.2 provides a comprehensive review of the nation’s electricity system and cover the current state and key trends related to the electricity system, including generation, transmission, distribution, grid operations and planning, and end use. The baseline reports provide an overview of elements of the electricity system. This report focuses on end uses, electricity consumption, electric energy efficiency, distributed energy resources (DERs) (such as demand response, distributed generation, and distributed storage), and evaluation, measurement, and verification (EM&V) methods for energy efficiency and DERs.

  1. Carbon footprint of the Danish electricity transmission and distribution systems

    DEFF Research Database (Denmark)

    Turconi, Roberto; Astrup, Thomas Fruergaard

    , and relevant auxiliary infrastructures. Electricity T&D provided respectively 29 and 17 gCO2e/kWh, mainly related to power losses. Emissions from distribution were larger than those from transmission, because of higher losses and higher complexity and material consumption. Large differences were found between......The electricity sector is among the main sources of greenhouse gas (GHG) emissions; today, those are mainly due to combustion of fossil fuels, but with increasing renewable sources the importance of infrastructures both in electricity generation and in transmission and distribution (T......&D) will likely grow. Several studies are available on renewable energy technologies, but only a few on transmission of electricity, and none on its distribution. This study provides life cycle inventory data for electricity distribution networks, and a life cycle GHG accounting of the Danish T&D networks...

  2. Plan 2000. The electricity companies plan for electricity conservation in the millennium; Plan 2000. Elselskabernes plan for elbesparelser i det nye aartusinde

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-01

    Plan 2000 presents an account of the activities in the years 1997 and 1998 and a budget for the year 2000 and forwards. The report includes all 82 electricity companies in Denmark. Furthermore a number of particular analyses of relevance to electricity conservation are presented. All electricity companies work to promote electricity conservation. All consumption sizes and sections are covered. The activities in the individual companies are supported by a number of common campaigns. In Plan 2000 those activities are presented and the economics is analysed. The activities in the first year of the plan are expected to result in conservation corresponding 4% of the present electricity consumption. 80% of the conservation comes from activities, which are measurable. Technical counselling of trade customers is one of the essential activities. Others are e.g. telephone counselling, theme arrangements and teaching of pupils. (EHS)

  3. Wind Power in Electrical Distribution Systems

    DEFF Research Database (Denmark)

    Chen, Zhe

    2013-01-01

    Recent years, wind power is experiencing a rapid growth, large number of wind turbines/wind farms have been installed and connected to power systems. In addition to the large centralised wind farms connected to transmission grids, many distributed wind turbines and wind farms are operated...... as distributed generators in distribution systems. This paper discusses the issues of wind turbines in distribution systems. Wind power conversion systems briefly introduced, the basic features and technical characteristics of distributed wind power system are described, and the main technical demands...

  4. 76 FR 64291 - Airworthiness Directives; General Electric Company (GE) Turbofan Engines

    Science.gov (United States)

    2011-10-18

    ...-09-AD RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) Turbofan Engines AGENCY...-80C2B7F, CF6-80C2B8F, CF6- 80C2D1F, CF6-80C2K1F, and CF6-80C2L1F turbofan engines, including engines marked on the engine data plate as CF6-80C2B7F1. This proposed AD was prompted by a report of a supplier...

  5. The electric power engineering handbook electric power generation, transmission, and distribution

    CERN Document Server

    Grigsby, Leonard L

    2012-01-01

    Featuring contributions from worldwide leaders in the field, the carefully crafted Electric Power Generation, Transmission, and Distribution, Third Edition (part of the five-volume set, The Electric Power Engineering Handbook) provides convenient access to detailed information on a diverse array of power engineering topics. Updates to nearly every chapter keep this book at the forefront of developments in modern power systems, reflecting international standards, practices, and technologies. Topics covered include: * Electric Power Generation: Nonconventional Methods * Electric Power Generation

  6. Power Quality Improvement in Electrical Distribution Network

    OpenAIRE

    Oladepo Olatunde; Awofolaju Tolulope Tola

    2016-01-01

    The introduction of Distributed Generation (DG) in a distribution system offers several benefits to utilities, customers and society. However, the integration of these sources into the networks can cause some challenges regarding their expected impacts on the security and the dynamic behaviour of the entire network. This paper presents the Modified Particle Swarm Optimization algorithm (MPSOA) to determine the optimal location and size of Distributed Generation and Capacitor banks to maximizi...

  7. Agent Based Control of Electric Power Systems with Distributed Generation

    DEFF Research Database (Denmark)

    Saleem, Arshad

    Distributed generation, decentralized and local control, self organization and autonomy are evident trends of today's electric power systems focusing on innovative control architectures such as MicroGrids, Virtual Power Plants, Cell based systems, plug-in electric vehicles and real time markets...... have been developed particularly in the area of communication and distributed control. Electric power industry is eager to explore, evaluate and adopt these new advancements in ICT for improving its current practices of automation and control in order to cope with above mentioned challenges....... This thesis focuses on making a systematic evaluation of using intelligent software agent technology for control of electric power systems with high penetration of distributed generation. The thesis is based upon a requirement driven approach. It starts with investigating new trends and challenges in Electric...

  8. FACTORS OF REFUSALS IN ELECTRICAL DISTRIBUTION NETWORKS 10 KV

    Directory of Open Access Journals (Sweden)

    V. POPESCU

    2017-03-01

    Full Text Available At present, in electrical distribution networks with tension 10 kV take place a significant number of refusals, which affect the reliability of electricity supply to all consumers. The behavior of these interruptions permit the development of the mechanism for ensuring continuity of electricity supply to consumers. Ensurance of continuity of quality power supply of consumer can be achieved only on the bases of profound knowledge of the phenomena that accompany this process, which permits a justified planning from technical and economic point of view, measures and activities of exploitation services of electrical distribution networks with tension 10 kV, in view to ensure the normal indicators of reliability. The paper is devoted to assessing the distributions of refusals in electrical networks with tension 10 kV, for developing the forecasting mechanism and to ensure the reliability of power supply.

  9. Investment Cost Model in Business Process Intelligence in Banking And Electricity Company

    Directory of Open Access Journals (Sweden)

    Arta Moro Sundjaja

    2016-06-01

    Full Text Available Higher demand from the top management in measuring business process performance causes the incremental implementation of BPM and BI in the enterprise. The problem faced by top managements is how to integrate their data from all system used to support the business and process the data become information that able to support the decision-making processes. Our literature review elaborates several implementations of BPI on companies in Australia and Germany, challenges faced by organizations in developing BPI solution in their organizations and some cost model to calculate the investment of BPI solutions. This paper shows the success in BPI application of banks and assurance companies in German and electricity work in Australia aims to give a vision about the importance of BPI application. Many challenges in BPI application of companies in German and Australia, BPI solution, and data warehouse design development have been discussed to add insight in future BPI development. And the last is an explanation about how to analyze cost associated with BPI solution investment.

  10. [Tampa Electric Company IGCC project]. 1996 DOE annual technical report, January--December 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project uses a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,000 tons per day of coal to syngas. The gasification plant is coupled with a combined cycle power block to produce a net 250 MW electrical power output. Coal is slurried in water, combined with 95% pure oxygen from an air separation unit, and sent to the gasifier to produce a high temperature, high pressure, medium-Btu syngas with a heat content of about 250 BTUs/cf (HHV). The syngas then flows through a high temperature heat recovery unit which cools the syngas prior to its entering the cleanup systems. Molten coal ash flows from the bottom of the high temperature heat recovery unit into a water-filled quench chamber where it solidifies into a marketable slag by-product. Approximately 10% of the raw, hot syngas at 900 F is designed to pass through an intermittently moving bed of metal-oxide sorbent which removes sulfur-bearing compounds from the syngas. PPS-1 will be the first unit in the world to demonstrate this advanced metal oxide hot gas desulfurization technology on a commercial unit. The emphasis during 1996 centered around start-up activities.

  11. Business Pattern of Distributed Energy in Electric Power System Reformation

    Science.gov (United States)

    Liang, YUE; Zhuochu, LIU; Jun, LI; Siwei, LI

    2017-05-01

    Under the trend of the electric power system revolution, the operation mode of micro power grid that including distributed power will be more diversified. User’s demand response and different strategies on electricity all have great influence on the operation of distributed power grid. This paper will not only research sensitive factors of micro power grid operation, but also analyze and calculate the cost and benefit of micro power grid operation upon different types. Then it will build a tech-economic calculation model, which applies to different types of micro power grid under the reformation of electric power system.

  12. Solar repowering system for Texas Electric Service Company Permian Basin Steam Electric Station Unit No. 5. Final report, executive summary

    Energy Technology Data Exchange (ETDEWEB)

    1980-07-15

    The conceptual design and economic assessment of a sodium-cooled, solar central receiver repowering system for Texas Electric Service Company's Permian Basin Steam Electric Plant Unit No. 5 are described. As expected, the economic assessment of the specific concept for that site indicates that the cost of energy is greater than that resulting from the burning of natural gas alone in the existing plant (principally as a result of the current cost of heliostats and the scheduled retirement date of Unit No. 5), Favorable economics for similar types of plants can be projected for the future. The annual fuel savings are equivalent to 218,500 barrels of crude oil, with a total dollar value of $21.5 M and $93.6 M for a 7-year life and a 25-year life, respectively. However, it has also been found, from separate studies, that favorable interpretations of the Fuel Use Act and an improved regulatory climate will be necessary for this economic viability to be reached. In particular, a subsidized program to reduce the cost of heliostats to less than $100/m/sup 2/ will be needed. All sodium components, except the receiver, are available on the basis of similar-sized or larger components that have been designed, fabricated, tested and operated in power plants for hundred of thousands of hours. Liquid sodium has been demonstrated for use as a stable, safe, and easily contained heat transfer fluid up to temperature exceeding those required for modern steam plants. (WHK)

  13. Real-Time Procurement Strategies of a Proactive Distribution Company with Aggregator-Based Demand Response

    DEFF Research Database (Denmark)

    Zhang, Chunyu; Wang, Qi; Wang, Jianhui

    2016-01-01

    and inelastic demand components. A one-leader multi-follower bilevel model is proposed to derive the procurement strategies, i.e., the upper-level problem intends to maximize the profit of the proactive distribution company, while the lower-level expresses the profit maximization per rational aggregator...

  14. An Overview of Power Quality Enhancement Techniques Applied to Distributed Generation in Electrical Distribution Networks

    DEFF Research Database (Denmark)

    Naderi Zarnaghi, Yahya; hosseini, Seyed Hossein; Ghassem Zadeh, Saeed

    2017-01-01

    It is obvious that power quality is an important characteristic of today’s distribution power systems as loads become more sensitive on the other hand nonlinear loads are increasing in the electrical distribution system. Considering the distributed nature of harmonic loads, the need for distribut...

  15. Electric Vehicle (EV) Charging Management with Dynamic Distribution System Tariff

    DEFF Research Database (Denmark)

    O'Connell, Niamh; Wu, Qiuwei; Østergaard, Jacob

    2011-01-01

    An electric vehicle (EV) charging schedule algorithm was proposed in this paper in order to charge EVs to meet EV users’ driving needs with the minimum EV charging cost and respect the local distribution system constraints. A day-ahead dynamic distribution system tariff scheme was proposed to avoid...

  16. POSSIBILITIES OF APPLYING THE DEA METHOD IN THE ASSESSMENT OF EFFICIENCY OF COMPANIES IN THE ELECTRIC POWER INDUSTRY: REVIEW OF WIND ENERGY COMPANIES

    Directory of Open Access Journals (Sweden)

    Dario Maradin

    2014-07-01

    Full Text Available One of the fundamental tasks of modern power system is finding ways to produce stable and continuous electricity from scarce energy resources. One of the possible solutions is introduction, implementation and improvement of alternative forms of energy such as renewable energy sources, particularly wind energy as an increasingly important energy source which is expected to further increase its share in total electricity production. Numerous methods can be used in assessing the efficiency of wind energy companies, and in the focus of this research is the Data Envelopment Analysis method (DEA, a widely accepted methodology given its interdisciplinary approach and flexibility. This method represents a step forward in the field of renewable energy management, because it provides the possibility to compare the selected companies with the best in the industry (the most efficient and the possibility of determining sources of inefficiency and, consequently, the possibilities of their elimination.

  17. Power Distribution Analysis For Electrical Usage In Province Area Using Olap (Online Analytical Processing

    Directory of Open Access Journals (Sweden)

    Samsinar Riza

    2018-01-01

    Full Text Available The distribution network is the closest power grid to the customer Electric service providers such as PT. PLN. The dispatching center of power grid companies is also the data center of the power grid where gathers great amount of operating information. The valuable information contained in these data means a lot for power grid operating management. The technique of data warehousing online analytical processing has been used to manage and analysis the great capacity of data. Specific methods for online analytics information systems resulting from data warehouse processing with OLAP are chart and query reporting. The information in the form of chart reporting consists of the load distribution chart based on the repetition of time, distribution chart on the area, the substation region chart and the electric load usage chart. The results of the OLAP process show the development of electric load distribution, as well as the analysis of information on the load of electric power consumption and become an alternative in presenting information related to peak load.

  18. State Electricity Regulatory Policy and Distributed Resources: Accommodating Distributed Resources in Wholesale Markets

    Energy Technology Data Exchange (ETDEWEB)

    Weston, F.; Harrington, C.; Moskovitz, D.; Shirley, W.; Cowart, R.; Sedano, R.

    2002-10-01

    Distributed resources can provide cost-effective reliability and energy services - in many cases, obviating the need for more expensive investments in wires and central station electricity generating facilities. Given the unique features of distributed resources, the challenge facing policymakers today is how to restructure wholesale markets for electricity and related services so as to reveal the full value that distributed resources can provide to the electric power system (utility grid). This report looks at the functions that distributed resources can perform and examines the barriers to them. It then identifies a series of policy and operational approaches to promoting DR in wholesale markets. This report is one in the State Electricity Regulatory Policy and Distributed Resources series developed under contract to NREL (see Annual Technical Status Report of the Regulatory Assistance Project: September 2000-September 2001, NREL/SR-560-32733). Other titles in this series are: (1) Distributed Resource Distribution Credit Pilot Programs - Revealing the Value to Consumers and Vendors, NREL/SR-560-32499; (2) Distributed Resources and Electric System Reliability, NREL/SR-560-32498; (3) Distribution System Cost Methodologies for Distributed Generation, NREL/SR-560-32500; (4) Distribution System Cost Methodologies for Distributed Generation Appendices, NREL/SR-560-32501

  19. Sequential time-step generation companies decisions in oligopolistic electricity market

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez-Alcaraz, Guillermo [Programa de Graduados e Investigacion en Ingenieria Electrica, Departamento de Ingenieria Electrica y Electronica del Instituto Tecnologico de Morelia, Morelia, Michoacan (Mexico)

    2008-05-15

    This paper studies the production decisions of generation companies (GENCOs) which are fully engaged in oligopolistic electricity markets. The model presented is based upon the static equilibrium model solved sequentially in time. By decomposing the problem in time, each time-step is solved independently using a Cournot-like market model. The time dimension is divided into discrete, 1-h time-steps. The model also incorporates the effects of technical and temporal constraints such as time on/off and ramp up/down. Since GENCOs tend toward repetitive decision-making, they can more easily learn from the market. The concept of forward expectations and the lessons derived from the market are introduced, and several numerical examples are provided. (author)

  20. Distributed Electrical Energy Systems: Needs, Concepts, Approaches and Vision

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yingchen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zhang, Jun [University of Denver; Gao, Wenzhong [University of Denver; Zheng, Xinhu [University of Minnesota; Yang, Liuqing [Colorado State University; Hao, Jun [University of Denver; Dai, Xiaoxiao [University of Denver

    2017-09-01

    Intelligent distributed electrical energy systems (IDEES) are featured by vast system components, diversifled component types, and difficulties in operation and management, which results in that the traditional centralized power system management approach no longer flts the operation. Thus, it is believed that the blockchain technology is one of the important feasible technical paths for building future large-scale distributed electrical energy systems. An IDEES is inherently with both social and technical characteristics, as a result, a distributed electrical energy system needs to be divided into multiple layers, and at each layer, a blockchain is utilized to model and manage its logic and physical functionalities. The blockchains at difierent layers coordinate with each other and achieve successful operation of the IDEES. Speciflcally, the multi-layer blockchains, named 'blockchain group', consist of distributed data access and service blockchain, intelligent property management blockchain, power system analysis blockchain, intelligent contract operation blockchain, and intelligent electricity trading blockchain. It is expected that the blockchain group can be self-organized into a complex, autonomous and distributed IDEES. In this complex system, frequent and in-depth interactions and computing will derive intelligence, and it is expected that such intelligence can bring stable, reliable and efficient electrical energy production, transmission and consumption.

  1. Proceedings of the electricity distribution information systems and technology conference and exhibition : developing flexible networks : building the energy pathway of tomorrow

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This conference provided a forum for electric utility operators, electrical engineers, and information technology professionals to discuss industry developments, including smart metering technology applications for managing power transmission and distribution. In addition to the traditional roles of electricity supply and customer service, local electricity distribution companies in Ontario must now respond to new network requirements and capabilities within their service area. Among the topics discussed at the conference were methods to improve reliability; best management practices in emergency planning; interconnecting distributed generation from renewable energy sources to the power grid; and network connectivity models. The conference featured 18 presentations, of which 3 have been catalogued separately for inclusion in this database. tabs., figs.

  2. Electrical Power Distribution and Control Modeling and Analysis

    Science.gov (United States)

    Fu, Johnny S.; Liffring, Mark; Mehdi, Ishaque S.

    2001-01-01

    This slide presentation reviews the use of Electrical Power Distribution and Control (EPD&C) Modeling and how modeling can support analysis. The presentation discusses using the EASY5 model to simulate and analyze the Space Shuttle Electric Auxiliary Power Unit. Diagrams of the model schematics are included, as well as graphs of the battery cell impedance, hydraulic load dynamics, and EPD&C response to hydraulic load variations.

  3. Integration of Electric Vehicles in Low Voltage Danish Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Thøgersen, Paul; Møller, Jan

    2012-01-01

    in the electricity grid operation, a careful examination in the local electricity system is essential. This paper investigates the degree of EV penetration and its key influence on the low voltage distribution grids. Three detailed models of residential grids in Denmark are considered as test cases in this study......Electric Vehicles (EVs) are considered as one of the important components of the future intelligent grids. Their role as energy storages in the electricity grid could provide local sustainable solutions to support more renewable energy. In order to estimate the extent of interaction of EVs...... are reflected as the major technical constraint to the stable operation of the electricity grids for integrating more EVs, when compared to the thermal loading on the cables....

  4. Control strategies for power distribution networks with electric vehicles integration

    DEFF Research Database (Denmark)

    Hu, Junjie

    Demand side resources, like electric vehicles (EVs), can become integral parts of a smart grids because instead of just consuming power they are capable of providing valuable services to power systems. EVs can be used to balance the intermittent renewable energy resources such as wind and solar....... EVs can absorb energy during periods of high electricity production and feed the electricity back into the grid when the demand is high or in situations of insucient electricity generation. However, extra loads created by the increasing number of EVs may have adverse impacts on the distribution...... strategies supported by an increased use of information and communication technology. This is the idea of the smart grid. The smart grid is a next-generation electrical power system that is typied by the increased use of communications and information technology in the generation, delivery and consumption...

  5. Charging Schedule for Electric Vehicles in Danish Residential Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2015-01-01

    , the vehicle owner, vehicle fleet operator and other parties involved in the process could economically benefit from the process. This paper investigates an optimal EV charging plan in Danish residential distribution grids in view of supporting high volumes of wind power in electricity grids. The results......The prospects of Electric Vehicles (EVs) in providing clean transportation and supporting renewable electricity is widely discussed in sustainable energy forums worldwide. The battery storage of EVs could be used to address the variability and unpredictability of electricity produced from renewable...... energy sources like wind in power systems. The EV batteries could be used to charge during periods of excess electricity production from wind power and reduce the charging rate or discharge on deficit of power in the grid, supporting system stability and reliability. By providing such grid services...

  6. Performance management system in sale and distribution: A case of Serbian company

    Directory of Open Access Journals (Sweden)

    Aleksandar Jankulović

    2013-09-01

    Full Text Available Background: Performance management system (PMS is the process of quantifying action which leads to organizational efficiency, competitiveness and growth. Performance measurement is the vital element of quality management system (QMS. Innovative companies have a strong culture, clear sense of mission and purpose, a well thought out strategy and business philosophy of continuous improvement, driven by QMS. Implementation of QMS ISO9001 standards has encouraged many organizations to develop and implement performance management system. Statement of quality objectives and Measurement, analysis and improvement as a part of QMS which leads to continual improvement is a vital part of success of company. Therefore PMS influence on sale, distribution and logistics companies with a complex processes and great number of subjects in supply chain are of great importance for their success. Methods: In our research we analyse measures and measurement approaches and frameworks that exist in logistic management and based on that we present results from one SME from eastern European country. We use case study research and therefore we conduct interviews with managers, employees and QMS/PMS implementation staff in sale and distribution company. Results: The aim of this study was to estimate the value of various metrics of the evaluation of QMS implementation. The study was based on case study in one Serbian sale and distribution company specifically in measurement part and metrics that are essential for their business and to compare them with approaches existed in literature. We reveal some obstacles in collecting data for measurement and benchmarking in Serbian market. Different metrics for efficient management of company are implemented in this company based on sales results and customer satisfaction.  Conclusion:  The importance of the research is in the fact that implementation of QMS reveal the need for PMS implementation and therefore results in certain

  7. Social and Environmental Disclosure: An Analysis of Social Balance of Electricity Sector Companies in the South and Northeast Regions of Brazil

    Directory of Open Access Journals (Sweden)

    Tchiara Aparecida Maçambanni

    2013-06-01

    Full Text Available Based on the social responsibility indicators of the Instituto Brasileiro de Análises Sociais e Econômicas (IBASE model, this paper identifies the social and environmental disclosure level of electricity distribution companies in Brazilian market. The method chosen was the descriptive research to obtain results in a qualitative approach for the problem. The technical procedure used was documentary research. Data was collected over the social balance sheet released by several companies’ websites between 2009 and 2010. In the Northeast region, the companies Companhia de Eletricidade do Estado da Bahia (COELBA, Companhia Energética de Pernambuco (CELPE and Companhia Energética do Rio Grande do Norte (COSERN had the highest levels of social disclosure. COELBA, for example, obtained the maximum score according to the score methodology proposed by the paper. Coming from the South area, the best ranked was Companhia Paranaense de Energia (COPEL, from Paraná state, which disclosed 99% of the information analyzed in this study. Average level of disclosure of companies by region remained practically stable between the years 2009 and 2010. In general, companies located in the Northeast region evidenced a higher percentage of social and environmental information compared to companies of South region.

  8. Distributed Frequency Control of Prosumer-Based Electric Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Nazari, MH; Costello, Z; Feizollahi, MJ; Grijalva, S; Egerstedt, M

    2014-11-01

    In this paper, we propose a distributed frequency regulation framework for prosumer-based electric energy systems, where a prosumer (producer-consumer) is defined as an intelligent agentwhich can produce, consume, and/or store electricity. Despite the frequency regulators being distributed, stability can be ensured while avoiding inter-area oscillations using a limited control effort. To achieve this, a fully distributed one-step model-predictive control protocol is proposed and analyzed, whereby each prosumer communicates solely with its neighbors in the network. The efficacy of the proposed frequency regulation framework is shown through simulations on two real-world electric energy systems of different scale and complexity. We show that prosumers can indeed bring frequency and power deviations to their desired values after small perturbations.

  9. The good, the bad and the ugly: The privatization of the Brazilian electricity distribution sector

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, Bruno; Hall, Jeremy; Matos, Stelvia; Figuiera, Luiz Augusto

    2010-09-15

    This paper analyzes the evolution of five electricity distribution companies in the Northeast of Brazil using technical and financial indexes. Three privatized and two public firms were analyzed between 1997 and 2008. The financial indexes are related to the capacity of the business to generate value for shareholders, while the technical indexes are related to the quality of service provided to customers. We observed the privatized firms had their financial indexes improved after the privatization, increasing the value of the firm for the shareholders. However, there is no evidence that the privatization affected the quality of service provided to consumers.

  10. Evaluation of a distribution model for a new beer company production site

    Directory of Open Access Journals (Sweden)

    Gustavo Menoncin Pereira

    2014-12-01

    Full Text Available Ambev dominates the beer market in Brazil with a 70% share. The group formed in the 1990s by the merger of the two largest companies in the industry at the time, Brahma and Antarctica. Even with new entrants in the market AmBev kept growing and increasing its participation. One of the biggest challenges to work in the beer market is the distribution strategy. AmBev’s success has, in its distribution strategy, one of the critical factors in reaching this level of market share. The model AmBev has implemented and continues to invest is what Brahma, pre AmBev, adopted as its strategy in the 1990s. This work aims to determine whether, in a company starting its production activities in the same industry, the AmBev distribution model can be applied. Based on the concepts of logistics and supply chain management, the possible concepts of distribution strategies were identified, seeking to understand those underlying the AmBev reference model. With this, a company has been identified and a case study conducted to understand the application of the AmBev model. The main findings of the study point to possibilities for adopting the model, but with restrictions and constant monitoring to control the implementation of the strategy.

  11. THE USE OF NEW DISTRIBUTION CHANNELS TO INCREASE THE EFFICIENCY OF INSURANCE COMPANIES

    Directory of Open Access Journals (Sweden)

    Olga N. Kozlova

    2017-09-01

    Full Text Available The article deals with the issues of increasing the efficiency of insurance companies on the basis of using new non-traditional distribution channels. The relevance of the topic is justified by the automation of management processes, a new generation of consumers focused on new technologies, the use of the Internet, growing and selling functional mobile gadgets. The insurance companies use new distribution channels via the Internet network along with the traditional means for the expansion of the insurance portfolio and attracting active and passive consumers. The calculations carried out on the basis of the data of the Bank of Russia show that the share of such sales is growing, but not leading. The use of the Internet depends on many factors, but primarily on the types of insurance. The authors carry out calculations on the use of distribution channels in various types of insurance. The complexity and variety of products on life insurance requires qualified intermediaries, therefore, the use of new distribution channels here is not widespread in contrast to classical accident insurance or compulsory insurance, where sales are more efficient when organizing through the Internet. Selling through Internet has a number of advantages that reduce the cost of doing business, reduce the agency network, the cost of print advertising to attract passive and strengthen the relationship with active consumers. The authors also conduct analysis of the advantages and disadvantages of using mobile gadgets to work with potential customers, quantitative and qualitative benefits of implementing mobile apps in the work of insurance companies. The conclusions are made about the complexity of calculation of economic efficiency of implementing mobile applications. The possible directions of increasing the efficiency of using new distribution channels by insurance companies are defined.

  12. Optimal Operation of Electric Vehicles in Competitive Electricity Markets and Its Impact on Distribution Power Systems

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2011-01-01

    represent the future of electricity markets in some ways, is chosen as the studied power system in this paper. The impact of the optimal operation strategy for electric vehicles together with the optimal load response to spot market price on the distribution power system with high wind power penetrations......Since the hourly spot market price is available one day ahead in Denmark, the electricity price could be transferred to the consumers and they may make some optimal charge and discharge schedules for their electric vehicles in order to minimize their energy costs. This paper presents an optimal...... operation strategy for a Plug-In Electric Vehicle (PEV) in relation to the hourly electricity price in order to achieve minimum energy costs of the PEV. The western Danish power system, which is currently the grid area in the world that has the largest share of wind power in its generation profiles and may...

  13. Area-Specific Marginal Costing for Electric Utilities: a Case Study of Transmission and Distribution Costs

    Science.gov (United States)

    Orans, Ren

    1990-10-01

    Existing procedures used to develop marginal costs for electric utilities were not designed for applications in an increasingly competitive market for electric power. The utility's value of receiving power, or the costs of selling power, however, depend on the exact location of the buyer or seller, the magnitude of the power and the period of time over which the power is used. Yet no electric utility in the United States has disaggregate marginal costs that reflect differences in costs due to the time, size or location of the load associated with their power or energy transactions. The existing marginal costing methods used by electric utilities were developed in response to the Public Utilities Regulatory Policy Act (PURPA) in 1978. The "ratemaking standards" (Title 1) established by PURPA were primarily concerned with the appropriate segmentation of total revenues to various classes-of-service, designing time-of-use rating periods, and the promotion of efficient long-term resource planning. By design, the methods were very simple and inexpensive to implement. Now, more than a decade later, the costing issues facing electric utilities are becoming increasingly complex, and the benefits of developing more specific marginal costs will outweigh the costs of developing this information in many cases. This research develops a framework for estimating total marginal costs that vary by the size, timing, and the location of changes in loads within an electric distribution system. To complement the existing work at the Electric Power Research Institute (EPRI) and Pacific Gas and Electric Company (PGandE) on estimating disaggregate generation and transmission capacity costs, this dissertation focuses on the estimation of distribution capacity costs. While the costing procedure is suitable for the estimation of total (generation, transmission and distribution) marginal costs, the empirical work focuses on the geographic disaggregation of marginal costs related to electric

  14. [Investigation on occupational stress of workers in clean workshops of electric company].

    Science.gov (United States)

    Sun, Ya-qiang; Mao, Li-feng; Feng, Jian-liang; Xu, Bai-qing; Luo, Chen; Ni, Chun-hui

    2013-07-01

    The aim is to learn the situation of work stress, burnout and depression in clean workshops of electronic company by investigation, and provide the clues for the further interventions as well as the basic data for the future evaluation. The survey was carried out in a electronic company in Xishan,Wuxi city. The subjects including all the 395 employees in clean workshops and 205 in ordinary workshops were asked to fill in an anonymous cross-sectional questionnaire, in which the distributions of age, gender, job duration, working time and working strength were similar between two kinds of workshops. The response rate was 98.9%. There were no significant differences between clean and ordinary workshops in age, gender, smoking, drinking and working hours, except for employed years. It was not found that any differences between two kinds of workshop for the rates of burnout, depression and stress. However, the rates of burnout, depression and stress were 19.7%(77/391), 24.8%(97/391) and 88.5%(346/391) in clean workshops and 19.3%(39/202), 23.8%(48/202) and 84.6%(171/202) in ordinary workshops. There were no significant differences between two workshops for the scores of burnout and depression, but the stress score in clean workshops was higher than that of ordinary workshop (P = 0.015). Further stratified analysis found that stress score of male in clean workshop was higher than that of female (P = 0.002), while it was inverse in ordinary workshops (P = 0.034). In addition, the stress score of male in clean workshops was significantly higher than that of male in ordinary one (P = 0.003). The stress score of workers with age ≥22 year old was higher than that of age company. The stress in clean workshops was more serious than that of ordinary ones, especially for the males.

  15. Modeling of electric field distribution in tissues during electroporation.

    Science.gov (United States)

    Corovic, Selma; Lackovic, Igor; Sustaric, Primoz; Sustar, Tomaz; Rodic, Tomaz; Miklavcic, Damijan

    2013-02-21

    Electroporation based therapies and treatments (e.g. electrochemotherapy, gene electrotransfer for gene therapy and DNA vaccination, tissue ablation with irreversible electroporation and transdermal drug delivery) require a precise prediction of the therapy or treatment outcome by a personalized treatment planning procedure. Numerical modeling of local electric field distribution within electroporated tissues has become an important tool in treatment planning procedure in both clinical and experimental settings. Recent studies have reported that the uncertainties in electrical properties (i.e. electric conductivity of the treated tissues and the rate of increase in electric conductivity due to electroporation) predefined in numerical models have large effect on electroporation based therapy and treatment effectiveness. The aim of our study was to investigate whether the increase in electric conductivity of tissues needs to be taken into account when modeling tissue response to the electroporation pulses and how it affects the local electric distribution within electroporated tissues. We built 3D numerical models for single tissue (one type of tissue, e.g. liver) and composite tissue (several types of tissues, e.g. subcutaneous tumor). Our computer simulations were performed by using three different modeling approaches that are based on finite element method: inverse analysis, nonlinear parametric and sequential analysis. We compared linear (i.e. tissue conductivity is constant) model and non-linear (i.e. tissue conductivity is electric field dependent) model. By calculating goodness of fit measure we compared the results of our numerical simulations to the results of in vivo measurements. The results of our study show that the nonlinear models (i.e. tissue conductivity is electric field dependent: σ(E)) fit experimental data better than linear models (i.e. tissue conductivity is constant). This was found for both single tissue and composite tissue. Our results of

  16. 76 FR 66333 - Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental...

    Science.gov (United States)

    2011-10-26

    ... COMMISSION Carolina Power & Light Company, H.B. Robinson Steam Electric Plant, Unit No. 2; Environmental... permit are needed. No effects on the aquatic or terrestrial habitat in the vicinity or the plant, or to..., ``Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors,'' and 10 CFR...

  17. 75 FR 43099 - Airworthiness Directives; General Electric Company (GE) CT7-9C and -9C3 Turboprop Engines

    Science.gov (United States)

    2010-07-23

    ... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) CT7-9C and -9C3 Turboprop Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... (AD) for GE CT7-9C and -9C3 turboprop engines with certain serial number (S/ N) gas generator turbine...

  18. 76 FR 70382 - Airworthiness Directives; General Electric Company (GE) CF6-80C2B Series Turbofan Engines

    Science.gov (United States)

    2011-11-14

    ... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) CF6-80C2B Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... directive (AD) that applies to all GE CF6-80C2B series turbofan engines. The existing AD currently requires...

  19. 75 FR 21161 - Airworthiness Directives; General Electric Company (GE) CJ610 Series Turbojet Engines and CF700...

    Science.gov (United States)

    2010-04-23

    ...-02-AD; Amendment 39-16273; AD 2010-09-08] RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) CJ610 Series Turbojet Engines and CF700 Series Turbofan Engines AGENCY: Federal Aviation...) for GE CJ610 series turbojet engines and CF700 turbofan engines with AFT Technologies combustion...

  20. 75 FR 70096 - Airworthiness Directives; General Electric Company (GE) CT7-9C and -9C3 Turboprop Engines

    Science.gov (United States)

    2010-11-17

    ...-04-AD; Amendment 39-16509; AD 2010-23-20] RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) CT7-9C and -9C3 Turboprop Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... result in an uncontained engine failure and damage to the airplane. DATES: This AD is effective December...

  1. 77 FR 24541 - Virginia Electric and Power Company, North Anna Power Station Units 1 and 2, Independent Spent...

    Science.gov (United States)

    2012-04-24

    ... significantly impact the quality of the human environment. The NRC staff concludes that there are no changes... of the environment. The Environmental Assessment and the Finding of No Significant Impact are... Fuel Storage Installation; Exemption 1.0 Background Virginia Electric and Power Company (Dominion, the...

  2. 77 FR 24539 - Virginia Electric and Power Company; Surry Power Station Units 1 and 2; Independent Spent Fuel...

    Science.gov (United States)

    2012-04-24

    ... significantly impact the quality of the human environment. The NRC staff concludes that there are no changes... of the environment. The Environmental Assessment and the Finding of No Significant Impact are... COMMISSION Virginia Electric and Power Company; Surry Power Station Units 1 and 2; Independent Spent Fuel...

  3. Institutional Governance Framework for Determining Carbon-related Accounting Practices: An Exploratory Study of Electricity Generating Companies in Malaysia

    Science.gov (United States)

    Alrazi, B.; Mat Husin, N.

    2016-03-01

    Electricity industry is the major contributor of the global carbon emissions which has been scientifically identified as the main cause of climate change. With the various initiatives being implemented at the international, national, and industry levels, companies in the electricity industry are currently facing immense pressure from various stakeholders to demonstrate their policies, initiatives, targets, and performance on climate change. Against this background, accounting system is argued to be able to be play important roles in combating climate change. Using institutional governance as the underlying framework, we have identified several governance mechanisms as the determining factors for companies to have a systematic accounting system related to carbon emissions. The factors include environmental management system certification, environmental organization, publication of stand-alone sustainability reports, the use of GRI guidelines, environmental strategic planning, governance quality, and participation in CDP surveys and emissions trading scheme. We explored this issue in the context of major electricity generating companies in Malaysia and found that except for certified environmental management system, the other governance mechanisms are still lacking. The findings suggest that companies in Malaysia, in particular, from the electricity industry are not well prepared in facing risks related to climate change.

  4. Results of the Study on the Role and Penetration of Sesame Street and the Electric Company in Ghetto Communities.

    Science.gov (United States)

    Children's Television Workshop, New York, NY.

    The findings of a 1973 study covering the performance of Sesame Street and The Electric Company in ghetto communities are reported briefly. The steps taken to repeat the methodology of earlier Sesame Street studies are described. Data are given on: penetration of Sesame Street among preschool children in Bedford Stuyvesant, East Harlem, Chicago,…

  5. Relative Pricing of Publicly Traded U.S. Electric Utility Companies

    Science.gov (United States)

    Jewczyn, Nicholas Stephen

    In the financial turmoil of 2008, U.S. firms reported debt-ratios that differed from the debt-ratios calculated from balance sheets. The problem is that investors bought common stock expecting initial investment return and lost money when companies delisted. The purpose of this quantitative study was to determine sample securities pricing with the application of synthetic assets and debt accrued. Addressed in the research questions was whether those securities were (a) underpriced compared with return-on-assets (ROA), (b) overpriced compared with ROA, (c) a debt-ratio higher than 60% and also overpriced, (d) underpriced with a synthetic asset added, or (e) related by relative pricing to variant pricing and market capitalization. The study's base theory was Pan's efficient market hypothesis (EMH) of security price prediction of market prices versus model prices. The data from the financial statements of 16 publicly traded U.S. electric utility companies were analyzed via correlations and multiple regression analyses to determine securities pricing and suitability. The findings from the analyses of the sample's variables of market price, book value, market-to-book, and study constructed variables from those variable data were statistically significant. The alternate hypotheses were accepted for all 5 research questions since the analytical operationalization of the hypothetical constructs led to significant relationships. Results suggest that the use of more pricing determinants in securities evaluation may lead to investors losing less money and earning the expected returns for a more efficient capital market, leading to a stronger economy and macroeconomic stability.

  6. Operation of Modern Distribution Power Systems in Competitive Electricity Markets

    DEFF Research Database (Denmark)

    Hu, Weihao

    , DG units, loads and electricity price are studied. Further, the effect of energy storage systems will be considered, and an optimal operation strategy for energy storage devices in a large scale wind power system in the electricity market is proposed. The western Danish power system, which has large...... maximum profit of the BESS is proposed. Two kinds of BESS, based on polysulfide-bromine (PSB) and vanadium redox (VRB) battery technologies, are studied. Optimal operation strategies of PEV in the spot market are then proposed in order to decrease the energy cost for PEV owners. Furthermore......In this dissertation, the characteristics of a distribution system under a dynamic electricity-pricing, load management system and under a large number of power electronic interfaced distributed generation units are investigated. The operation characteristics of a power system with wind turbines...

  7. Electric field distribution and simulation of avalanche formation due ...

    Indian Academy of Sciences (India)

    Electric field distributions and their role in the formation of avalanche due to the passage of heavy ions in parallel grid avalanche type wire chamber detectors are evaluated using a Monte Carlo simulation. The relative merits and demerits of parallel and crossed wire grid configurations are studied. It is found that the crossed ...

  8. Structural vulnerability analysis of electric power distribution grids

    NARCIS (Netherlands)

    Koc, Y.; Raman, Abhishek; Warnier, M.E.; Kumar, Tarun

    2016-01-01

    Power grid outages cause huge economical and societal costs. Disruptions in the power distribution grid are responsible for a significant fraction of electric power unavailability to customers. The impact of extreme weather conditions, continuously increasing demand, and the over-ageing of assets

  9. Electricity distribution industry restructuring in South Africa: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, C.T. [University of Cape Town, Rondebosch (South Africa)

    2008-09-15

    For 20 years there has been vigorous debate about restructuring the large, developed electricity industry in South Africa, but the plans have not been implemented. The justification of the proposed restructuring illustrates the different expectations of the participants in the electricity industry. The case study reviews what has occurred against a background of some theories about organisations, and identifies six key issues. Some lessons include the need to adopt an industry structure compatible with the objectives of electricity distribution in developing countries, the unsuitability of orthodox approaches to organisations, that no industry structure appears to be significantly better than others, industry restructuring of public sector utilities has a significant political dimension, restructuring can fail even if there is support from a high level of government, and indecision and uncertainty have serious negative consequences. The experience should be helpful for other developing countries considering structural change of their electricity industry. (author)

  10. Electrical distribution studies for the 200 Area tank farms

    Energy Technology Data Exchange (ETDEWEB)

    Fisler, J.B.

    1994-08-26

    This is an engineering study providing reliability numbers for various design configurations as well as computer analyses (Captor/Dapper) of the existing distribution system to the 480V side of the unit substations. The objective of the study was to assure the adequacy of the existing electrical system components from the connection at the high voltage supply point through the transformation and distribution equipment to the point where it is reduced to its useful voltage level. It also was to evaluate the reasonableness of proposed solutions of identified deficiencies and recommendations of possible alternate solutions. The electrical utilities are normally considered the most vital of the utility systems on a site because all other utility systems depend on electrical power. The system accepts electric power from the external sources, reduces it to a lower voltage, and distributes it to end-use points throughout the site. By classic definition, all utility systems extend to a point 5 feet from the facility perimeter. An exception is made to this definition for the electric utilities at this site. The electrical Utility System ends at the low voltage section of the unit substation, which reduces the voltage from 13.8 kV to 2,400, 480, 277/480 or 120/208 volts. These transformers are located at various distances from existing facilities. The adequacy of the distribution system which transports the power from the main substation to the individual area substations and other load centers is evaluated and factored into the impact of the future load forecast.

  11. 76 FR 30573 - Airworthiness Directives; General Electric Company (GE) GE90-110B1 and GE90-115B Turbofan Engines

    Science.gov (United States)

    2011-05-26

    ... Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with high-pressure compressor (HPC) stages... Federal Aviation Administration 14 CFR Part 39 RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) GE90- 110B1 and GE90-115B Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...

  12. [Cardiovascular risk factors among shift workers in company of electricity production in the centre of Tunisia].

    Science.gov (United States)

    Chatti, S; Debbabi, F; Ben Abdelaziz, A; Harbaoui, R; Ghannem, H; Mrizak, N

    2010-08-01

    The aim of the present study was to investigate relationship between shift work and the cardiovascular risk factors. A cross-sectional study was included 330 subjects worked in a company of electricity production in the Centre of Tunisia. The collection of data was based on a questionnaire, a clinical exam and biomarkers. A total of 290 workers was participated in our study (128 shift workers and 162 daytime workers). A raised prevalence but not statistically significant of some factors of cardiovascular risks was found in the shift workers: obesity (25.8 % versus 17.9 %), smoking (44.5 % versus 39.5 %), impaired fasting glucose (11.7 % versus 9.9 %), hypertriglyceridemia (28.1 % versus 25.9 %) and hypercholesterolemia (14.8 % versus 12.4 %). Whereas the prevalence of the alcohol consumption (25.8 % versus 16.0 %) was significantly higher in the shift workers (p=0.04). The high prevalence of the cardiovascular risk factors, observed in our shift workers, justify the adoption of measures to protect this category of workers. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  13. Distribution of new graphic warning labels: Are tobacco companies following regulations?

    Directory of Open Access Journals (Sweden)

    Hoek Janet

    2009-08-01

    Full Text Available Abstract Objective To test the hypothesis that tobacco companies would not follow a regulation that required seven new graphic health warnings (GHWs to be evenly distributed on cigarette packs and that they would distribute fewer packs featuring warnings regarded by smokers as being more disturbing. Methods Cross-sectional survey of purchased packs (n = 168 and street-collected discarded packs (convenience sample of New Zealand cities and towns, n = 1208 packs with statistical analysis of seven types of new GHWs. A priori warning impact was judged using three criteria, which were tested against data from depth interviews with retailers. Results The GHWs on the purchased packs and street-collected packs both showed a distribution pattern that was generally consistent with the hypothesis ie, there were disproportionately more packs featuring images judged as "least disturbing" and disproportionately fewer of those with warnings judged "more disturbing". The overall patterns were statistically significant, suggesting an unequal frequency of the different warnings for both purchased (p Conclusion These results suggest that tobacco companies are not following the regulations, which requires even distribution of the seven different GHWs on cigarette packs; further monitoring is required to estimate the extent of this non-compliance. As an immediate measure, governments should strictly enforce all regulations applying to health warnings, particularly given that these are an effective tobacco control intervention that cost tax payers nothing.

  14. Distribution of AC Contact Network Electric Field Strenght

    Directory of Open Access Journals (Sweden)

    Antonio Andonov

    2004-01-01

    Full Text Available To provide the stock electromagnetics compatibility is a serious problem with the contemporary development of the railway transport and implementation of lines for connection. The AS contact system is on of the main equipment of the electrify railway transport that implements the electrical connection between the traction substations and the roiling stock. But it is also one of the main sources of interference due to the presence of its strong electromagnetic field. The paper present an distribution of electric intensity by contact system.

  15. Modelling grid losses and the geographic distribution of electricity generation

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2005-01-01

    In Denmark more than 40% of the electricity consumption is covered by geographically scattered electricity sources namely wind power and local CHP (cogeneration of heat and power) plants. This causes problems in regard to load balancing and possible grid overloads. The potential grid problems...... and methods for solving these are analysed in this article on the basis of energy systems analyses, geographic distribution of consumption and production and grid load-flow analyses. It is concluded that by introducing scattered load balancing using local CHP plants actively and using interruptible loads...

  16. 17 CFR 270.12b-1 - Distribution of shares by registered open-end management investment company.

    Science.gov (United States)

    2010-04-01

    ... written) or other understanding under which the company directs, or is expected to direct, portfolio... made by such company in connection with such distribution are made pursuant to a written plan... person relating to implementation of the plan are in writing: And further provided, That: (1) Such plan...

  17. Analyzing Distributed Generation Impact on the Reliability of Electric Distribution Network

    OpenAIRE

    Sanaullah Ahmad; Sana Sardar; Babar Noor; Azzam ul Asar

    2016-01-01

    With proliferation of Distribution Generation (DG) and renewable energy technologies the power system is becoming more complex, with passage of time the development of distributed generation technologies is becoming diverse and broad. Power system reliability is one of most vital area in electric power system which deals with continuous supply of power and customer satisfaction. Distribution network in power system contributed up to 80% of reliability problems. This paper analyzes the impact ...

  18. Electric current distribution of a multiwall carbon nanotube

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Li-Ying; Chang, Chia-Seng, E-mail: jasonc@phys.sinica.edu.tw [Department of Physics, National Taiwan University, Taipei 10617, Taiwan (China); Institute of Physics, Academia Sinica, Taipei 11529, Taiwan (China); Nano Science and Technology Program, Taiwan International Graduate Program, Academia Sinica and National Taiwan University, Taiwan (China); Chen, Yu-Jyun [Institute of Physics, Academia Sinica, Taipei 11529, Taiwan (China)

    2016-07-15

    The electric current distribution in a multiwall carbon nanotube (MWCNT) was studied by in situ measuring the electric potential along an individual MWCNT in the ultra-high vacuum transmission electron microscope (TEM). The current induced voltage drop along each section of a side-bonded MWCNT was measured by a potentiometric probe in TEM. We have quantitatively derived that the current on the outermost shell depends on the applied current and the shell diameter. More proportion of the total electronic carriers hop into the inner shells when the applied current is increased. The larger a MWCNT’s diameter is, the easier the electronic carriers can hop into the inner shells. We observed that, for an 8 nm MWCNT with 10 μA current applied, 99% of the total current was distributed on the outer two shells.

  19. Voltage Support from Electric Vehicles in Distribution Grid

    DEFF Research Database (Denmark)

    Huang, Shaojun; Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2013-01-01

    The paper evaluates the voltage support functions from electric vehicles (EVs) on a typical Danish distribution grid with high EV penetration. In addition to the popular voltage control modes, such as voltage droop charging (low voltage level leads to low charging power) and reactive power support......, the combination of these two methods is also examined for controlled EV charging. Simulation results show that the combination of the two individual supporting methods has the best performance in terms of voltage regulation as well as improving EV penetration level at weak distribution grids....

  20. Load research and load estimation in electricity distribution

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A. [VTT Energy, Espoo (Finland). Energy Systems

    1996-12-31

    The topics introduced in this thesis are: the Finnish load research project, a simple form customer class load model, analysis of the origins of customers load distribution, a method for the estimation of the confidence interval of customer loads and Distribution Load Estimation (DLE) which utilises both the load models and measurements from distribution networks. The Finnish load research project started in 1983. The project was initially coordinated by the Association of Finnish Electric Utilities and 40 utilities joined the project. Now there are over 1000 customer hourly load recordings in a database. A simple form customer class load model is introduced. The model is designed to be practical for most utility applications and has been used by the Finnish utilities for several years. The only variable of the model is the customers annual energy consumption. The model gives the customers average hourly load and standard deviation for a selected month, day and hour. The statistical distribution of customer loads is studied and a model for customer electric load variation is developed. The model results in a lognormal distribution as an extreme case. Using the `simple form load model`, a method for estimating confidence intervals (confidence limits) of customer hourly load is developed. The two methods selected for final analysis are based on normal and lognormal distribution estimated in a simplified manner. The estimation of several cumulated customer class loads is also analysed. Customer class load estimation which combines the information from load models and distribution network load measurements is developed. This method, called Distribution Load Estimation (DLE), utilises information already available in the utilities databases and is thus easy to apply

  1. Troubleshooting the General Electric Company Neutron Devices Department's deionized water system

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, T.J.

    1983-11-15

    In May 1982, the General Electric Neutron Devices Department's deionized (DI) water system was found to be highly contaminated with fresh water roundworms which caused severe filter plugging problems. Subsequently, a DI water improvement program was developed by GEND's Process Technology, Contamination Control, and Facilities Engineering groups. This program included removal of dead ends in the distribution system, a consultant's review, significant modification of the DI water system, modification of system operation, design of a quality plan, and changes in the types of water analysis. During implementation of the improvement program, a severe bacteria contamination problem occurred due to a contractor accident. Correction of this problem required sterilization of portions of the DI water system and significant modification of the water filtration system. The system modifications and sterilization procedures have significantly reduced bacteria and total solids contamination while resistivity is generally increasing.

  2. Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

    Science.gov (United States)

    Soltis, James V.

    1998-01-01

    The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

  3. Real-time Trading Strategies for Proactive Distribution Company with Distributed Generation and Demand Response

    DEFF Research Database (Denmark)

    Wang, Qi

    ) directly procuring capacities from local DG and DR. In this situation, a hierarchical market structure is achieved comprising the transmission-level (TL) and distribution-level (DL) markets. Focusing on the real-time process, as the interface actor, the DISCO's behavior covers downwardly procuring DL DG...... and DR resources, and upwardly trading in the TL real-time market, resulting in a proactive manner. The DL aggregator (DA) is dened to manage these small-scale and dispersed DGs and DRs. A methodology is proposed in this thesis for a proactive DISCO (PDISCO) to strategically trade with DAs...... in the presented DL market and transact with TL real-time market. A one-leader multi-follower-type bi-level model is proposed to indicate the PDISCO's trading strategies. To participate in the TL real-time market, a methodology is presented to derive continuous bidding/offering strategies for a PDISCO. A bi...

  4. Heat engine and electric motor torque distribution strategy for a hybrid electric vehicle

    Science.gov (United States)

    Boberg, Evan S.; Gebby, Brian P.

    1999-09-28

    A method is provided for controlling a power train system for a hybrid electric vehicle. The method includes a torque distribution strategy for controlling the engine and the electric motor. The engine and motor commands are determined based upon the accelerator position, the battery state of charge and the amount of engine and motor torque available. The amount of torque requested for the engine is restricted by a limited rate of rise in order to reduce the emissions from the engine. The limited engine torque is supplemented by motor torque in order to meet a torque request determined based upon the accelerator position.

  5. Impact of Electric Vehicle Charging Station Load on Distribution Network

    Directory of Open Access Journals (Sweden)

    Sanchari Deb

    2018-01-01

    Full Text Available Recent concerns about environmental pollution and escalating energy consumption accompanied by the advancements in battery technology have initiated the electrification of the transportation sector. With the universal resurgence of Electric Vehicles (EVs the adverse impact of the EV charging loads on the operating parameters of the power system has been noticed. The detrimental impact of EV charging station loads on the electricity distribution network cannot be neglected. The high charging loads of the fast charging stations results in increased peak load demand, reduced reserve margins, voltage instability, and reliability problems. Further, the penalty paid by the utility for the degrading performance of the power system cannot be neglected. This work aims to investigate the impact of the EV charging station loads on the voltage stability, power losses, reliability indices, as well as economic losses of the distribution network. The entire analysis is performed on the IEEE 33 bus test system representing a standard radial distribution network for six different cases of EV charging station placement. It is observed that the system can withstand placement of fast charging stations at the strong buses up to a certain level, but the placement of fast charging stations at the weak buses of the system hampers the smooth operation of the power system. Further, a strategy for the placement of the EV charging stations on the distribution network is proposed based on a novel Voltage stability, Reliability, and Power loss (VRP index. The results obtained indicate the efficacy of the VRP index.

  6. Characterization of industrial waste from a natural gas distribution company and management strategies: a case study of the East Azerbaijan Gas Company (Iran).

    Science.gov (United States)

    Taghipour, Hassan; Aslhashemi, Ahmad; Assadi, Mohammad; Khodaei, Firoz; Mardangahi, Baharak; Mosaferi, Mohammad; Roshani, Babak

    2012-10-01

    Although a fundamental prerequisite for the successful implementation of any waste management plan is the availability of sufficient and accurate data, there are few available studies regarding the characterization and management of gas distribution company waste (GDCW). This study aimed to characterize the industrial waste generated by the East Azerbaijan Gas Distribution Company (EAGDC) and to present environmental management strategies. The EAGDC serves 57 cities and 821 villages with a total population of more than 2.5 million as well as numerous industrial units. The methodology of this study was based on a checklist of data collected from each zone of the company, site visits (observation), and quantity and quality analysis according to the formal data available from different zones. The results indicate that more than 35 different kinds of industrial solid waste are generated in different industrial installations. The most important types of generated waste include empty barrels (including mercaptans, diesel fuel, deionized waters and oil), faulty gas meters and regulators, a variety of industrial oils, sleeves, filter elements and faulty pipes, valves and fittings. The results indicated that, currently, GDCW is generally handled and disposed of with domestic waste, deposited in companies' installation yards and stores or, sometimes, recycled through non-scientific approaches that can create health risks to the public and the environment, even though most of the GDCW was determined to be recyclable or reusable materials. This study concludes that gas distribution companies must pay more attention to source reduction, recycling and reusing of waste to preserve natural resources, landfill space and the environment.

  7. Harmonic Impact of Plug-In Hybrid Electric Vehicle on Electric Distribution System

    Directory of Open Access Journals (Sweden)

    A. Aljanad

    2016-01-01

    Full Text Available This paper presents the harmonic effects of plug-in hybrid electric vehicles (PHEV on the IEEE 37-bus distribution system at different PHEV penetration levels considering a practical daily residential load shape. The PHEV is modeled as a current harmonic source by using the Open-Source Distribution System Simulator (OpenDSS and DSSimpc software. Time series harmonic simulation was conducted to investigate the harmonic impact of PHEV on the system by using harmonic data obtained from a real electric vehicle. Harmonic effects on the system voltage profile and circuit power losses are also investigated by using OpenDSS and MATLAB software. Current/voltage total harmonic distortion (THD produced from the large scale of PHEV is investigated. Test results show that the voltage and current THDs are increased up to 9.5% and 50%, respectively, due to high PHEV penetrations and these THD values are significantly larger than the limits prescribed by the IEEE standards.

  8. Technical and economic feasibility of distributed generation of electricity; Viabilidade tecnica e economica de geracao distribuida de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Frederico Augusto Ornelas; Espirito Santo, Marcos Vinicius do; Leite, Leonardo Henrique de Melo; Silva, Arlete Vieira da [Centro Universitario de Belo Horizonte (UnBH), MG (Brazil)], e-mails: fred.aor@hotmail.com, marcos_ves@yahoo.com.br, leonardo.leite@prof.unibh.br, arlete.silva@prof.unibh.br

    2011-07-01

    This article focuses on the technical and economic feasibility of the design and implementation of energy micro nets distributed generation (GD). For this, a study was conducted in a rural area to assess the potential of generating electricity from renewable sources, and this has assisted the Brazilian network of conventional energy. We studied the renewable energy village, considered the conventional system of generation, transmission, distribution of electricity in this region and the technical and economic feasibility of implementing distributed generation and its interconnection to the basic network or not. The methodological procedures were used bibliographic and documentary research, interviews with standardized forms, and Case Study. This study was conducted in Minas Gerais assessing the current conditions of the electrification of the area surveyed and deployment of the types of electricity sources - biomass (biogas and burning eucalyptus), wind, solar photovoltaic. The calculations were made from it with companies and budgets. It is conceived, then, models of generating electricity through renewable sources constitutes a GD. Finally, they estimated the costs of implementation of the models studied in the community where they were cost estimates for electric power production through private investment, considering some possible scenarios to be created, namely: generation for own consumption, generation the sale of surplus and possible expansions. In this way demonstrated the high value of the investments required for the use of renewable sources in electricity generation small, given the current scenario. (author)

  9. Aeroelastic Analysis of a Distributed Electric Propulsion Wing

    Science.gov (United States)

    Massey, Steven J.; Stanford, Bret K.; Wieseman, Carol D.; Heeg, Jennifer

    2017-01-01

    An aeroelastic analysis of a prototype distributed electric propulsion wing is presented. Results using MSC Nastran (Registered Trademark) doublet lattice aerodynamics are compared to those based on FUN3D Reynolds Averaged Navier- Stokes aerodynamics. Four levels of grid refinement were examined for the FUN3D solutions and solutions were seen to be well converged. It was found that no oscillatory instability existed, only that of divergence, which occurred in the first bending mode at a dynamic pressure of over three times the flutter clearance condition.

  10. Drive system failure control for distributed drive electric vehicles

    Science.gov (United States)

    Liu, Tao; Tang, Yuan; Wang, Jianfeng; Li, Yaou; Yang, Na; Liu, Yiqun

    2017-09-01

    Aiming at the failure problem of distributed electric drive vehicle, the conventional control strategy of drive system failure is designed according to the characteristics of each wheel torque independent control and the redundant configuration of the power unit. On this basis, combined with the traditional body stability control technology, the direct yaw moment control method is used. The simulation results show that the conventional control method designed of the drive system failure can effectively improve the driving condition of the vehicle. The driving stability of the vehicle is further improved after the direct yaw torque control is applied.

  11. Technique applied in electrical power distribution for Satellite Launch Vehicle

    OpenAIRE

    João Maurício Rosário; Fábio Duarte Spina; José Walter Parquet Bizarria; Francisco Carlos P. Bizarria

    2010-01-01

    Abstract: The Satellite Launch Vehicle electrical network, which is currently being developed in Brazil, is sub-divided for analysis in the following parts: Service Electrical Network, Controlling Electrical Network, Safety Electrical Network and Telemetry Electrical Network. During the pre-launching and launching phases, these electrical networks are associated electrically and mechanically to the structure of the vehicle. In order to succeed in the integration of these electrical networks i...

  12. CLARKE AND WRIGHT SAVING ALGORITHM AS A MEANS OF DISTRIBUTION STREAMLINING IN THE ENVIRONMENT OF A CONCRETE COMPANY

    Directory of Open Access Journals (Sweden)

    Martin Straka

    2015-03-01

    Full Text Available Reducing costs forces of companies to look for reserves also in field of management, support and implementation of material flow. This is connected with the optimization of costs for product distribution, which forms a significant part of the total cost of the company. In practice, it happens that making plans for distribution of materials within a distribution space is left solely to the implementers of distribution and it drivers of vehicles. As a result is uneconomic material distribution and unnecessary cost increases to his distribution. The objective of the paper is to propose a methodology for optimization of transport planning from DC Prešov to the individual Tesco units within the region that comes under this distribution centre. The methodology is based on the Clarke and Wright saving algorithm.

  13. Pricing of Delivery Orders Issued Under Basic Ordering Agreement DAAJO9-85-G-A025, General Electric Company-Aircraft Engine Business Group

    National Research Council Canada - National Science Library

    1991-01-01

    Our objectives were to determine whether Basic Ordering Agreement DAAJO9-85-G-AO25, Delivery Orders 0106 and 0124, awarded to the General Electric Company, were overpriced and the reasons for overpricing...

  14. Fault Diagnosis for Electrical Distribution Systems using Structural Analysis

    DEFF Research Database (Denmark)

    Knüppel, Thyge; Blanke, Mogens; Østergaard, Jacob

    2014-01-01

    is the design of efficient diagnostic algorithms, which is a prerequisite for fault-tolerant control of power distribution. Diagnosis in a grid depend on available analytic redundancies, and hence on network topology. When topology changes, due to earlier fault(s) or caused by maintenance, analytic redundancy...... relations (ARR) are likely to change. The algorithms used for diagnosis may need to change accordingly, and finding efficient methods to ARR generation is essential to employ fault-tolerant methods in the grid. Structural analysis (SA) is based on graph-theoretical results, that offer to find analytic......Fault-tolerance in electrical distribution relies on the ability to diagnose possible faults and determine which components or units cause a problem or are close to doing so. Faults include defects in instrumentation, power generation, transformation and transmission. The focus of this paper...

  15. Using ELECTRE TRI to support maintenance of water distribution networks

    Directory of Open Access Journals (Sweden)

    Flavio Trojan

    2012-08-01

    Full Text Available Problems encountered in the context of the maintenance management of water supply are evidenced by the lack of decision support models which gives a manager overview of the system. This paper, therefore, develops a model that uses, in its framework, the multicriteria outranking method ELECTRE TRI. The objective is to sort the areas of water flow measurement of a water distribution network, by priority of maintenance, with data collected from an automated system of abnormalities detection. This sorting is designed to support maintenance decisions in terms of the measure more appropriate to be applied per region. To illustrate the proposed model, an application was performed in a city with 100 thousand water connections. With this model it becomes possible to improve the allocation of maintenance measures for regions and mainly to improve the operation of the distribution network.

  16. Chattanooga Electric Power Board Case Study Distribution Automation

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Jim [Chattanooga Electric Power Board (EPB), TN (United States); Melin, Alexander M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Starke, Michael R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ollis, Ben [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    In 2009, the U.S. Department of Energy under the American Recovery and Reinvestment Act (ARRA) awarded a grant to the Chattanooga, Tennessee, Electric Power Board (EPB) as part of the Smart Grid Investment Grant Program. The grant had the objective “to accelerate the transformation of the nation’s electric grid by deploying smart grid technologies.” This funding award enabled EPB to expedite the original smart grid implementation schedule from an estimated 10-12 years to 2.5 years. With this funding, EPB invested heavily in distribution automation technologies including installing over 1,200 automated circuit switches and sensors on 171 circuits. For utilities considering a commitment to distribution automation, there are underlying questions such as the following: “What is the value?” and “What are the costs?” This case study attempts to answer these questions. The primary benefit of distribution automation is increased reliability or reduced power outage duration and frequency. Power outages directly impact customer economics by interfering with business functions. In the past, this economic driver has been difficult to effectively evaluate. However, as this case study demonstrates, tools and analysis techniques are now available. In this case study, the impact on customer costs associated with power outages before and after the implementation of distribution automation are compared. Two example evaluations are performed to demonstrate the benefits: 1) a savings baseline for customers under normal operations1 and 2) customer savings for a single severe weather event. Cost calculations for customer power outages are performed using the US Department of Energy (DOE) Interruption Cost Estimate (ICE) calculator2. This tool uses standard metrics associated with outages and the customers to calculate cost impact. The analysis shows that EPB customers have seen significant reliability improvements from the implementation of distribution automation. Under

  17. Defense Logistics Agency Aviation Generally Purchased SoleSource Spare Parts From the General Electric Company at Fair and Reasonable Prices, but Improvements Could Be Made (Redacted)

    Science.gov (United States)

    2015-07-24

    Defense Logistics Agency Aviation Generally Purchased Sole‑Source Spare Parts From the General Electric Company at Fair and Reasonable Prices, but...Purchased Sole‑Source Spare Parts From the General Electric Company at Fair and Reasonable Prices, but Improvements Could Be Made Visit us at...www.dodig.mil Objective Our audit objective was to determine whether the Defense Logistics Agency (DLA) Aviation was purchasing sole-source spare parts at

  18. Regulatory review and barriers for the electricity supply system for distributed generation in EU-15

    DEFF Research Database (Denmark)

    Ropenus, Stephanie; Skytte, Klaus

    2005-01-01

    When distributed electricity supply surpasses a particular level, it can no longer be ignored in planning and operation of the electricity networks. Therefore, improvements of the regulatory framework of the electricity networks are required along with the growth of the electricity supply from...... distributed generation. This paper reviews the current regulation of the grids with respect to distributed generation in EU-15 Member States and compares the different systems. Several barriers are identified....

  19. Communications architecture for an electric company, European utility communications architecture, EURUCA

    Energy Technology Data Exchange (ETDEWEB)

    Uuspaeae, P. [VTT Energy, Espoo (Finland)

    1998-08-01

    The scope of this research is integration and interoperability of various information systems and data communications for electric utilities. Utility Communication Architecture refers to an overall view of the communications needs and communication systems in an electric utility. The objective is to define and specify suitable and compatible communications procedures within the Utility and also to outside parties

  20. Impact of peak electricity demand in distribution grids: a stress test

    NARCIS (Netherlands)

    Hoogsteen, Gerwin; Molderink, Albert; Hurink, Johann L.; Smit, Gerardus Johannes Maria; Schuring, Friso; Kootstra, Ben

    2015-01-01

    The number of (hybrid) electric vehicles is growing, leading to a higher demand for electricity in distribution grids. To investigate the effects of the expected peak demand on distribution grids, a stress test with 15 electric vehicles in a single street is conducted and described in this paper.

  1. 29 CFR 1910.269 - Electric power generation, transmission, and distribution.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Electric power generation, transmission, and distribution... § 1910.269 Electric power generation, transmission, and distribution. Note: OSHA is staying the... the operation and maintenance of electric power generation, control, transformation, transmission, and...

  2. Space vehicle electrical power processing distribution and control study. Volume 1: Summary

    Science.gov (United States)

    Krausz, A.

    1972-01-01

    A concept for the processing, distribution, and control of electric power for manned space vehicles and future aircraft is presented. Emphasis is placed on the requirements of the space station and space shuttle configurations. The systems involved are referred to as the processing distribution and control system (PDCS), electrical power system (EPS), and electric power generation system (EPGS).

  3. Evolutionary Optimization of Electric Power Distribution Using the Dandelion Code

    Directory of Open Access Journals (Sweden)

    Jorge Sabattin

    2012-01-01

    Full Text Available Planning primary electric power distribution involves solving an optimization problem using nonlinear components, which makes it difficult to obtain the optimum solution when the problem has dimensions that are found in reality, in terms of both the installation cost and the power loss cost. To tackle this problem, heuristic methods have been used, but even when sacrificing quality, finding the optimum solution still represents a computational challenge. In this paper, we study this problem using genetic algorithms. With the help of a coding scheme based on the dandelion code, these genetic algorithms allow larger instances of the problem to be solved. With the stated approach, we have solved instances of up to 40,000 consumer nodes when considering 20 substations; the total cost deviates 3.1% with respect to a lower bound that considers only the construction costs of the network.

  4. Cardiac current density distribution by electrical pulses from TASER devices.

    Science.gov (United States)

    Stratbucker, Robert A; Kroll, Mark W; McDaniel, Wayne; Panescu, Dorin

    2006-01-01

    TASERs deliver electrical pulses that can temporarily incapacitate subjects. The goal of this paper is to analyze the distribution of TASER currents in the heart and understand their chances of triggering cardiac arrhythmias. The models analyzed herein describe strength-duration thresholds for myocyte excitation and ventricular fibrillation induction. Finite element modeling is used to compute current density in the heart for worst-case TASER electrode placement. The model predicts a maximum TASER current density of 0.27 mA/cm(2) in the heart. It is conclude that the numerically simulated TASER current density in the heart is about half the threshold for myocytes excitation and more than 500 times lower than the threshold required for inducing ventricular fibrillation. Showing a substantial cardiac safety margin, TASER devices do not generate currents in the heart that are high enough to excite myocytes or trigger VF.

  5. Global distribution of grid connected electrical energy storage systems

    Directory of Open Access Journals (Sweden)

    Katja Buss

    2016-06-01

    Full Text Available This article gives an overview of grid connected electrical energy storage systems worldwide, based on public available data. Technologies considered in this study are pumped hydroelectric energy storage (PHES, compressed air energy storage (CAES, sodium-sulfur batteries (NaS, lead-acid batteries, redox-flow batteries, nickel-cadmium batteries (NiCd and lithium-ion batteries. As the research indicates, the worldwide installed capacity of grid connected electrical energy storage systems is approximately 154 GW. This corresponds to a share of 5.5 % of the worldwide installed generation capacity. Furthermore, the article gives an overview of the historical development of installed and used storage systems worldwide. Subsequently, the focus is on each considered technology concerning the current storage size, number of plants and location. In summary it can be stated, PHES is the most commonly used technology worldwide, whereas electrochemical technologies are increasingly gaining in importance. Regarding the distribution of grid connected storage systems reveals the share of installed storage capacity is in Europe and Eastern Asia twice as high as in North America.

  6. STOCHASTIC MODELING OF OPTIMIZED CREDIT STRATEGY OF A DISTRIBUTING COMPANY ON THE PHARMACEUTICAL MARKET

    Directory of Open Access Journals (Sweden)

    M. Boychuk

    2015-10-01

    Full Text Available The activity of distribution companies is multifaceted. Ihey establish contacts with producers and consumers, determine the range of prices of medicines, do promotions, hold stocks of pharmaceuticals and take risks in their further selling.Their internal problems are complicated by the political crisis in the country, decreased purchasing power of national currency, and the rise in interest rates on loans. Therefore the usage of stochastic models of dynamic systems for the research into optimizing the management of pharmaceutical products distribution companies taking into account credit payments is of great current interest. A stochastic model of the optimal credit strategy of a pharmaceutical distributor in the market of pharmaceutical products has been constructed in the article considering credit payments and income limitations. From the mathematical point of view the obtained problem is the one of stochastic optimal control where the amount of monetary credit is the control and the amount of pharmaceutical product is the solution curve. The model allows to identify the optimal cash loan and the corresponding optimal quantity of pharmaceutical product that comply with the differential model of the existing quantity of pharmaceutical products in the form of Ito; the condition of the existing initial stock of pharmaceutical products; the limitation on the amount of credit and profit received from the product selling and maximize the average integral income. The research of the stochastic optimal control problem involves the construction of the left process of crediting with determination of the shift point of that control, the choice of the right crediting process and the formation of the optimal credit process. It was found that the optimal control of the credit amount and the shift point of that control are the determined values and don’t depend on the coefficient in the Wiener process and the optimal trajectory of the amount of

  7. Optimizing electricity distribution using two-stage integer recourse models

    NARCIS (Netherlands)

    Klein Haneveld, W.K.; van der Vlerk, M.H.; Uryasev, SP; Pardalos, PM

    2001-01-01

    We consider two planning problems faced by an electricity distributor. Electricity can be obtained both from power plants and small generators such as hospitals and greenhouses, whereas the future demand for electricity is uncertain. The price of electricity obtained from the power plants depends on

  8. Optimal interval for major maintenance actions in electricity distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Louit, Darko; Pascual, Rodrigo [Centro de Mineria, Pontificia Universidad Catolica de Chile, Av. Vicuna MacKenna, 4860 Santiago (Chile); Banjevic, Dragan [Centre for Maintenance Optimization and Reliability Engineering, University of Toronto, 5 King' s College Rd., Toronto, Ontario (Canada)

    2009-09-15

    Many systems require the periodic undertaking of major (preventive) maintenance actions (MMAs) such as overhauls in mechanical equipment, reconditioning of train lines, resurfacing of roads, etc. In the long term, these actions contribute to achieving a lower rate of occurrence of failures, though in many cases they increase the intensity of the failure process shortly after performed, resulting in a non-monotonic trend for failure intensity. Also, in the special case of distributed assets such as communications and energy networks, pipelines, etc., it is likely that the maintenance action takes place sequentially over an extended period of time, implying that different sections of the network underwent the MMAs at different periods. This forces the development of a model based on a relative time scale (i.e. time since last major maintenance event) and the combination of data from different sections of a grid, under a normalization scheme. Additionally, extended maintenance times and sequential execution of the MMAs make it difficult to identify failures occurring before and after the preventive maintenance action. This results in the loss of important information for the characterization of the failure process. A simple model is introduced to determine the optimal MMA interval considering such restrictions. Furthermore, a case study illustrates the optimal tree trimming interval around an electricity distribution network. (author)

  9. Fluctuations of company yearly profits versus scaled revenue: Fat tail distribution of Levy type

    OpenAIRE

    H. E. Roman; Siliprandi, R. A.; Dose, C.; Riccardi, C.; Porto,M.

    2008-01-01

    We analyze annual revenues and earnings data for the 500 largest-revenue U.S. companies during the period 1954-2007. We find that mean year profits are proportional to mean year revenues, exception made for few anomalous years, from which we postulate a linear relation between company expected mean profit and revenue. Mean annual revenues are used to scale both company profits and revenues. Annual profit fluctuations are obtained as difference between actual annual profit and its expected mea...

  10. The account manager: Link between the customer and the energy distribution company. De account-manager: Schakel tussen klant en energiebedrijf

    Energy Technology Data Exchange (ETDEWEB)

    Van Gelder, J.W.

    1993-05-01

    The monopolistic utility companies are rapidly turning into customer-oriented and efficient organizations. To be able to put client-oriented ideas into practice the whole organization has to be changed. A new job is that of account manager, the satellite between customer and energy company. Views and experiences of two distribution companies and the Nederlandse Gasunie are given and discussed. 3 ills.

  11. Integrated resource planning for local gas distribution companies: A critical review of regulatory policy issues

    Energy Technology Data Exchange (ETDEWEB)

    Harunuzzaman, M.; Islam, M.

    1994-08-01

    According to the report, public utility commissions (PUCs) are increasingly adopting, or considering the adoption of integrated resource planning (IRP) for local gas distribution companies (LDCs). The Energy Policy Act of 1992 (EPAct) requires PUCs to consider IRP for gas LDCs. This study has two major objectives: (1) to help PUCs develop appropriate regulatory approaches with regard to IRP for gas LDCs; and (2) to help PUCs respond to the EPAct directive. The study finds that it is appropriate for PUCs to pursue energy efficiency within the traditional regulatory framework of minimizing private costs of energy production and delivery; and PUCs should play a limited role in addressing environmental externalities. The study also finds that in promoting energy efficiency, PUCs should pursue policies that are incentive-based, procompetitive, and sensitive to rate impacts. The study evaluates a number of traditional and nontraditional ratemaking mechanisms on the basis of cost minimization, energy efficiency, competitiveness, and other criteria. The mechanisms evaluated include direct recovery of DSM expenses, lost revenue adjustments for DSM options, revenue decoupling mechanisms, sharing of DSM cost savings, performance-based rate of return for DSM, provision of DSM as a separate service, deregulation of DSM service, price caps, and deregulation of the noncore gas market. The study concludes with general recommendations for regulatory approaches and ratemaking mechanisms that PUCs may wish to consider in advancing IRP objectives.

  12. An empirical study on performance management: A case study of national Iranian oil Production Distribution Company

    Directory of Open Access Journals (Sweden)

    Abolhassan Faghihi

    2012-10-01

    Full Text Available The primary goal of creating a culture of performance management is to improve processes based on the responsibility of individuals and groups for the continuous improvement of business processes, and to contribute to their skills. In this paper, we discuss all related issues and indentify the most important aspects and components of performance management. The proposed study of this paper is to find out which performance management works best for national Iranian oil products distribution company (NIOPDC. The proposed study uses analytical hierarchy process to prioritize all important factors based on pair-wise comparison. We use geometric mean to find the average of comparisons and all computations are performed using Expert Choice software package. In summary, stakeholders (0.262 are the most important components of our survey followed by employee management (0.247, social responsibility (0.190 comes in the third position and quality of services (0.166 and internal process (0.134 are two less important factors in this survey.

  13. Distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Ness, E.

    1999-09-02

    Distributed generation, locating electricity generators close to the point of consumption, provides some unique benefits to power companies and customers that are not available from centralized electricity generation. Photovoltaic (PV) technology is well suited to distributed applications and can, especially in concert with other distributed resources, provide a very close match to the customer demand for electricity, at a significantly lower cost than the alternatives. In addition to augmenting power from central-station generating plants, incorporating PV systems enables electric utilities to optimize the utilization of existing transmission and distribution.

  14. Design and Development of a 200-kW Turbo-Electric Distributed Propulsion Testbed

    Science.gov (United States)

    Papathakis, Kurt V.

    2017-01-01

    There a few NASA funded electric and hybrid electric projects from different NASA Centers, including the NASA Armstrong Flight Research Center (AFRC) (Edwards, California). Each project identifies a specific technology gap that is currently inhibiting the growth and proliferation of relevant technologies in commercial aviation. This paper describes the design and development of a turbo-electric distributed propulsion (TeDP) hardware-in-the-loop (HIL) simulation bench, which is a test bed for discovering turbo-electric control, distributed electric control, power management control, and integration competencies while providing risk mitigation for future turbo-electric flying demonstrators.

  15. Construction of Industrial Ecosystem of an Electric Company under Ecological Perspective

    Science.gov (United States)

    Li, Xin; Zhang, Yuan; Wu, Han

    2018-01-01

    Be confronted with more and more fierce competition environment, only by constantly integrating, constructing and restructuring internal and external resources as well as capabilities can enterprises adapt themselves to the rapidly changing environment and maintain the advantages of sustained competition. Business competition has changed from product competition of single enterprise to competition of bussiness ecosystem. Therefore, how to build a business system is the key to win competition. This paper draws lessons from business ecosystem and industrial ecosystem concept and takes the subordinate industry company of a large enterprise as the research object. On the the basis of combing its characteristics and organizational structure, an industrial ecosystem is tired to constructed.

  16. 78 FR 45194 - General Electric Company; Analysis of Proposed Agreement Containing Consent Order To Aid Public...

    Science.gov (United States)

    2013-07-26

    ... engine manufacturer Snecma S.A. Avio is headquartered in Torino, Italy, and is an important designer and..., structural parts, gearboxes, and electrical systems for aircraft engines. Avio is currently the sole designer...--must be tested extensively and certified for flight by aviation authorities before it can be put into...

  17. OPTIMIZATION OF RELIABILITY ELECTRIC POWER TRANSMISSION AND DISTRIBUTION NETWORKS

    National Research Council Canada - National Science Library

    Dorin Sarchiz; Daniel Bucur

    2011-01-01

      The problem of quality services provided by suppliers of electricity is currently a major problem due to significant economic implications given the complexity and cost of electric power transmission...

  18. Distribution of electric currents in sunspots from photosphere to corona

    Energy Technology Data Exchange (ETDEWEB)

    Gosain, Sanjay [National Solar Observatory, 950 North Cherry Avenue, Tucson, AZ 85719 (United States); Démoulin, Pascal [Observatoire de Paris, LESIA, UMR 8109 (CNRS), F-92195 Meudon Principal Cedex (France); López Fuentes, Marcelo [Instituto de Astronomía y Física del Espacio (IAFE), UBA-CONICET, CC. 67, Suc. 28 Buenos Aires 1428 (Argentina)

    2014-09-20

    We present a study of two regular sunspots that exhibit nearly uniform twist from the photosphere to the corona. We derive the twist parameter in the corona and in the chromosphere by minimizing the difference between the extrapolated linear force-free field model field lines and the observed intensity structures in the extreme-ultraviolet images of the Sun. The chromospheric structures appear more twisted than the coronal structures by a factor of two. Further, we derive the vertical component of electric current density, j{sub z} , using vector magnetograms from the Hinode Solar Optical Telescope (SOT). The spatial distribution of j{sub z} has a zebra pattern of strong positive and negative values owing to the penumbral fibril structure resolved by Hinode/SOT. This zebra pattern is due to the derivative of the horizontal magnetic field across the thin fibrils; therefore, it is strong and masks weaker currents that might be present, for example, as a result of the twist of the sunspot. We decompose j{sub z} into the contribution due to the derivatives along and across the direction of the horizontal field, which follows the fibril orientation closely. The map of the tangential component has more distributed currents that are coherent with the chromospheric and coronal twisted structures. Moreover, it allows us to map and identify the direct and return currents in the sunspots. Finally, this decomposition of j{sub z} is general and can be applied to any vector magnetogram in order to better identify the weaker large-scale currents that are associated with coronal twisted/sheared structures.

  19. Electric Utility Transmission and Distribution Line Engineering Program

    Energy Technology Data Exchange (ETDEWEB)

    Peter McKenny

    2010-08-31

    Economic development in the United States depends on a reliable and affordable power supply. The nation will need well educated engineers to design a modern, safe, secure, and reliable power grid for our future needs. An anticipated shortage of qualified engineers has caused considerable concern in many professional circles, and various steps are being taken nationwide to alleviate the potential shortage and ensure the North American power system's reliability, and our world-wide economic competitiveness. To help provide a well-educated and trained workforce which can sustain and modernize the nation's power grid, Gonzaga University's School of Engineering and Applied Science has established a five-course (15-credit hour) Certificate Program in Transmission and Distribution (T&D) Engineering. The program has been specifically designed to provide working utility engineering professionals with on-line access to advanced engineering courses which cover modern design practice with an industry-focused theoretical foundation. A total of twelve courses have been developed to-date and students may select any five in their area of interest for the T&D Certificate. As each course is developed and taught by a team of experienced engineers (from public and private utilities, consultants, and industry suppliers), students are provided a unique opportunity to interact directly with different industry experts over the eight weeks of each course. Course material incorporates advanced aspects of civil, electrical, and mechanical engineering disciplines that apply to power system design and are appropriate for graduate engineers. As such, target students for the certificate program include: (1) recent graduates with a Bachelor of Science Degree in an engineering field (civil, mechanical, electrical, etc.); (2) senior engineers moving from other fields to the utility industry (i.e. paper industry to utility engineering or project management positions); and (3) regular

  20. RELIABILITY СONTROL OF ELECTRIC NETWORK SYSTEM AT JOINT-STOCK COMPANY «LENENERGO» UNDER CONDITIONS OF POWER ENGINEERING MODERNIZATION

    Directory of Open Access Journals (Sweden)

    A. P. Vasiliev

    2005-01-01

    Full Text Available During the last decade a general trend is observed among power engineering companies towards the deregulation of production activity. This social and political movement causes revaluation of reliability control of electric network system policy at Joint-Stock Company «Lenenergo», elaboration and development of methods and means for solution of integrated problems involving the whole process from putting into operation till equipment writing off.

  1. Planning and administration of human resources in Brazilian Electric Power Companies; Planejamento e administracao de recursos humanos nas empresas brasileiras do setor de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Devanir Vieira

    1985-12-01

    Administration and planning of human resources in Brazilian Companies of Electric Power Sector analyzes the evolution of the concept of business planning. This work explore the specific literature of this theme, giving emphasis in predict methods and human resources development and planning models. Is also presented a case study, realized in 1979, which comprehended 84 % of Brazilian Energy Companies. This study aims to evaluate the results of an implementation of this planning and development models 64 refs., 12 figs., 22 tabs.

  2. The Effects of Technology Entrepreneurship on Customers and Society: A Case Study of a Spanish Pharmaceutical Distribution Company.

    Science.gov (United States)

    Muñoz, Rosa M; Sánchez de Pablo, Jesús D; Peña, Isidro; Salinero, Yolanda

    2016-01-01

    The main purpose of this paper is to provide an understanding, within the field of corporate entrepreneurship, of the various factors that enable technology entrepreneurship in established firms and its principal effects on customers and society. The paper reports on a case study regarding technology entrepreneurship in a Spanish company whose activity is pharmaceutical distribution. This company has been able to overcome the consequences of the worldwide crisis and start an innovative process which includes the installation of new information technology (IT) and an investment of 6 million Euros. It is, in this respect, a model to imitate and the objective of this paper is therefore to discover the managers' entrepreneurial orientation (EO) characteristics which have made this possible, along with the organizational and social effects resulting from the process. We verify that EO is present in this company and that the development of new IT has important effects on customers and the population.

  3. The Effects of Technology Entrepreneurship on Customers and Society: A Case Study of a Spanish Pharmaceutical Distribution Company

    Science.gov (United States)

    Muñoz, Rosa M.; Sánchez de Pablo, Jesús D.; Peña, Isidro; Salinero, Yolanda

    2016-01-01

    The main purpose of this paper is to provide an understanding, within the field of corporate entrepreneurship, of the various factors that enable technology entrepreneurship in established firms and its principal effects on customers and society. The paper reports on a case study regarding technology entrepreneurship in a Spanish company whose activity is pharmaceutical distribution. This company has been able to overcome the consequences of the worldwide crisis and start an innovative process which includes the installation of new information technology (IT) and an investment of 6 million Euros. It is, in this respect, a model to imitate and the objective of this paper is therefore to discover the managers’ entrepreneurial orientation (EO) characteristics which have made this possible, along with the organizational and social effects resulting from the process. We verify that EO is present in this company and that the development of new IT has important effects on customers and the population. PMID:27445938

  4. Learning Medicinal Chemistry Absorption, Distribution, Metabolism, Excretion, and Toxicity (ADMET) Rules from Cross-Company Matched Molecular Pairs Analysis (MMPA).

    Science.gov (United States)

    Kramer, Christian; Ting, Attilla; Zheng, Hao; Hert, Jérôme; Schindler, Torsten; Stahl, Martin; Robb, Graeme; Crawford, James J; Blaney, Jeff; Montague, Shane; Leach, Andrew G; Dossetter, Al G; Griffen, Ed J

    2017-09-28

    The first large scale analysis of in vitro absorption, distribution, metabolism, excretion, and toxicity (ADMET) data shared across multiple major pharma has been performed. Using advanced matched molecular pair analysis (MMPA), we combined data from three pharmaceutical companies and generated ADMET rules, avoiding the need to disclose the full chemical structures. On top of the very large exchange of knowledge, all companies involved synergistically gained approximately 20% more rules from the shared transformations. There is good quantitative agreement between the rules based on shared data compared to both individual companies' rules and rules published in the literature. Known correlations between log D, solubility, in vitro clearance, and plasma protein binding also hold in transformation space, but there are also interesting exceptions. Data pools such as this allow focusing on particular functional groups and characterizing their ADMET profile. Finally the role of a corpus of robustly tested medicinal chemistry knowledge in the training of medicinal chemistry is discussed.

  5. Herbaceous crops for energy in Italy: Present status of the research program promoted by ENEL (Italian Electric Company)

    Energy Technology Data Exchange (ETDEWEB)

    Schenone, G. [ENEL CRAM, Milan (Italy)

    1996-12-31

    The paper presents a synthesis of the main results of the research program promoted by ENEL (Italian Electric Company) on herbaceous energy crops. The objective of the program is to evaluate the potentials of different species and cultivars for biomass fuel production in Italy. For the most promising species, all the links of the chain from cultivation to delivery at the plant gate at the lowest possible cost have to be organized. So far the following species gave annual productivities above 20 dry tons/ha: fiber sorghum (Sorghum sp.); miscanthus (Miscanthus sinensis); and giant reed (Arundo donax). The highest biomass yields, well above 40 dry tons/ha in several trials, were given by giant reed.

  6. ANALYSIS OF THE ELECTRICITY PRODUCTION POTENTIAL IN THE CASE OF RETROFIT OF STEAM TURBINES IN A DISTRICT HEATING COMPANY

    Directory of Open Access Journals (Sweden)

    Milun Babić

    2010-01-01

    Full Text Available Today, in Serbia there are several sites with installed combined heat and power facilities. The most of these plants, for various reasons, do not produce electricity. One such plant is "Energetika" (Kragujevac, Serbia, which is primarily a district heating company. Steam generator in the plant has been installed in the 1970's and has worked in one short period of time. Installed steam turbines are 8 MW and 20 MW rated power. "Energetika" in accordance with the general trend of increasing energy efficiency of production process initiated revitalization of the plant. This revitalization started with a study which approach and the results are briefly given in the paper. All results show that retrofit of facility should be acceptable for the management. Developed scenarios indicate that in the case of the limited resources optimal retrofit should start with smaller turbine (8 MW rated power then after providing the funds should continue with the retrofit of 20 MW turbine.

  7. Industrial Electricity. In-Plant Distribution. Vocational Trade and Industrial Education.

    Science.gov (United States)

    Teague, Cash; Pewewardy, Garner

    This curriculum guide, part of a series of industrial electricity curriculum guides, consists of materials for use in teaching a course on the in-plant distribution of electricity. Discussed in the introductory lessons are the National Electrical Code, power equipment, and blueprint reading. The next section, a series of units on branch-circuit…

  8. Oligopoly market models applied to electric utilities: How will generating companies behave in a deregulated industry?

    Science.gov (United States)

    Cunningham, Lance Brian

    An oligopoly market is analyzed which compares the oligopoly uniform market price to a fully competitive market price. The oligopoly consists of three electric utilities that behave as Cournot and Stackelberg leader---followers. A market simulation of the ERCOT market is also presented which includes the impact on market price when there are new market entrants into the oligopoly. The two case studies analyze the market with and without transmission constraints and identify how various transmission limitations can support strategic behavior by the utilities and ultimately impact the market price.

  9. Impacts of electric vehicle charging on distribution networks in Denmark

    DEFF Research Database (Denmark)

    Xu, Lizhong; Yang, Guang Ya; Xu, Zhao

    2011-01-01

    Electric vehicles (EVs) provide a unique opportunity to reduce carbon dioxide emissions from the transport sector by drawing on renewable resources. As EVs become increasingly popular in the automotive market, the study of its impacts on the low-voltage grid has become increasingly important...... network. Monte Carlo simulation is employed to study the impact of EVs in the presence of wind power considering different penetration levels of EVs, electricity price schemes and seasons. © 2011 State Grid Electric Power Research Institute Press....

  10. Impact of electric vehicles on power distribution networks

    OpenAIRE

    Putrus, Ghanim; Suwanapingkarl, Pasist; Johnston, David; Bentley, Edward; Narayana, Mahinsasa

    2009-01-01

    The market for battery powered and plug-in hybrid electric vehicles is currently limited, but this is expected to grow rapidly with the increased concern about the environment and advances in technology. Due to their high energy capacity, mass deployment of electrical vehicles will have significant impact on power networks. This impact will dictate the design of the electric vehicle interface devices and the way future power networks will be designed and controlled. This paper presents the re...

  11. Dynamics of electricity efficiency in commercial air-distribution systems in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Christiansson, Lena

    1996-04-01

    This paper illustrates the long-term potential for reducing future electricity demand for air-distribution in commercial buildings in Sweden. The objective has been to develop a general quantitative scenario-based framework to describe some possible paths for electricity demand for air distribution and to analyze how governmental and utility-sponsored policy measures can affect electricity demand. The focus is on improved electricity efficiency, i.e. a reduction of electricity demand for the same level of services. The results suggest that higher electricity prices will not be very effective in reducing electricity demand, whereas significant electricity savings can be reached by implementing various policy programs, particularly standards. 56 refs, 4 figs, 5 tabs

  12. Determining the Cost of Capital for Turkish Electricity Distribution Utilities: Analysis and Recommendations

    OpenAIRE

    GÖZEN, Mustafa

    2012-01-01

    Turkey has been transforming her electricity market to a competitive one since the electricity market law was approved by the parliament in 2001. As part of the new regime, electricity distribution activities are subject to incentive-based regulation by the energy regulator - EMRA. At the beginning of each implementation period, initial revenue is allowed by EMRA for a distribution utility in which a rate of return for investments in the utility is added. Setting a fair rate is relatively eas...

  13. A Concept Plane using electric distributed propulsion Evaluation of advanced power architecture

    OpenAIRE

    Ridel, M.; B. Paluch; Doll, C; Donjat, D.; Hermetz, J.; Guigon, A.; Schmollgruber, P.; Atinault, O.; Choy, P.; Le Tallec, P.; Dessornes, O.; Lefebvre, T

    2015-01-01

    International audience; Starting from electrical distributed propulsion system concept, the ONERA’s engineers demonstrated the viability of an all electrical aircraft for a small business aircraft. This paper describes the advanced power architecture considering energy conversion and power distribution. The design of this advanced power architecture requires the multi-physic integration of different domains as flight performances, safety and environmental requirements (thermal, electric, elec...

  14. Analysis and control of harmonic distortions on electrical distribution ...

    African Journals Online (AJOL)

    ... peak factor and harmonic distortions of the alternating or sinusoidal wave forms. The consequences of harmonic distortions of transmitted electrical energy might be damage of con-densers, untimely release of circuit breakers, resonance in the networks, warming of transformers and over heat-ing of electrical appliances.

  15. The new tariff model based on marginal costs developing concept for Brazilian electric sector. A case study for Power and Light Company of Sao Paulo State (Brazil); O novo modelo tarifario baseado no conceito de custos marginais em desenvolvimento para o setor eletrico brasileiro. Um estudo de caso para a Companhia Paulista de Forca e Luz

    Energy Technology Data Exchange (ETDEWEB)

    Correia, S.P.S.

    1991-12-31

    A new methodology for power generation cost accounts in Brazilian electric sector is described, with the application of marginal costs theory and its deviation in developing economies. A case report from a Brazilian Power and Light Company is studied, focalizing the seasoning, the planning, the tariff model and the power generation, transmission and distribution. (M.V.M.). 19 refs, 28 figs, 1 tab.

  16. 76 FR 82103 - Airworthiness Directives; General Electric Company (GE) GE90-110B1 and GE90-115B Turbofan Engines

    Science.gov (United States)

    2011-12-30

    ...-10-AD; Amendment 39-16901; AD 2011-26-11] RIN 2120-AA64 Airworthiness Directives; General Electric Company (GE) GE90- 110B1 and GE90-115B Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... failure of the seal of the HPC stages 2-5 spool, uncontained engine failure, and damage to the airplane...

  17. Electric Power Generation, Transmission and Distribution (NAICS 2211)

    Science.gov (United States)

    Find EPA regulatory information for electrical utilities, including coal-fired power plants. Includes links to NESHAPs for RICE, stationary combustion engines, fossil fuel waste, cooling water, effluent guidelines. Find information on the MATS rule.

  18. Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

  19. Project of law modified by the Senate relative to the electric and gas public utilities and to the electric and gas companies; Projet de loi modifie par le Senat relatif au service public de l'electricite et du gaz et aux entreprises electriques et gazieres

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This project of law aims to adapt the electricity and gas sector to the new economical context of opening of the energy markets to competition. It gives to energy companies the internal organization base necessary to warrant a high level of service and a transparent and non-discriminatory access of third parties to transport and distribution networks. These evolutions will allow Electricite de France (EdF) and Gaz de France (GdF) companies to compete on equal terms with their European competitors. It confirms first the prime role of public utility of both companies and then transposes the dispositions of the European directives relative to the organization of EdF and GdF integrated companies. It foresees the creation of two daughter companies for the management of energy transport activities. The project of law foresees also the change of the status of EdF and GdF companies and the reform of the retirement pensions of the personnel. This report presents the modifications added by the Senate to the text of law adopted at first reading by the House of Commons. (J.S.)

  20. Design and Development of a 200-kW Turbo-Electric Distributed Propulsion Testbed

    Science.gov (United States)

    Papathakis, Kurt V.; Kloesel, Kurt J.; Lin, Yohan; Clarke, Sean; Ediger, Jacob J.; Ginn, Starr

    2016-01-01

    The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) (Edwards, California) is developing a Hybrid-Electric Integrated Systems Testbed (HEIST) Testbed as part of the HEIST Project, to study power management and transition complexities, modular architectures, and flight control laws for turbo-electric distributed propulsion technologies using representative hardware and piloted simulations. Capabilities are being developed to assess the flight readiness of hybrid electric and distributed electric vehicle architectures. Additionally, NASA will leverage experience gained and assets developed from HEIST to assist in flight-test proposal development, flight-test vehicle design, and evaluation of hybrid electric and distributed electric concept vehicles for flight safety. The HEIST test equipment will include three trailers supporting a distributed electric propulsion wing, a battery system and turbogenerator, dynamometers, and supporting power and communication infrastructure, all connected to the AFRC Core simulation. Plans call for 18 high performance electric motors that will be powered by batteries and the turbogenerator, and commanded by a piloted simulation. Flight control algorithms will be developed on the turbo-electric distributed propulsion system.

  1. 78 FR 79298 - Securities Exempted; Distribution of Shares by Registered Open-End Management Investment Company...

    Science.gov (United States)

    2013-12-30

    ... Business Investment Companies, 23 FR 10484 (Dec. 30, 1958). \\2\\ Amendments to the Offering Exemption Under Regulation E of the Securities Act of 1933, 49 FR 35342 (Sept. 7, 1984). As part of Regulation E, rule 602... From the Federal Register Online via the Government Publishing Office SECURITIES AND EXCHANGE...

  2. Tampa Electric Company, Polk Power Station Unit No. 1. Annual report, January--December 1992

    Energy Technology Data Exchange (ETDEWEB)

    None

    1993-10-01

    As part of the Tampa Electric Polk Power Unit No. 1, a Texaco pressurized, oxygen-blown entrained-flow coal gasifier will convert approximately 2300 tons per day of coal (dry basis) into a medium-BTU fuel gas with a heat content of about 250 BTU/scf (LHV). Syngas produced in the gasifier flows through a high-temperature heat recovery unit which cools the gases prior to entering two parallel clean-up areas. A portion (up to 50%) of the hot syngas is cooled to 1000{degrees}F and passed through a moving bed of zinc titanate sorbent which removed sulfur containing components of the fuel gas. The project will be the first in the world to demonstrate this advanced metal oxide hot gas desulfurization technology at a commercial scale. The remaining portion of the syngas is cooled to 400{degrees}F for conventional acid gas removal. This portion of the plant is capable of processing between 50% and 100% of the dirty syngas. The cleaned low-BTU syngas is then routed to the combined cycle power generation system where it is mixed with air and burned in the gas turbine combustor. Heat is extracted from the expanded exhaust gases by a heat recovery steam generator to produce high pressure steam. This steam, along with the steam generated in the gasification process, drives a steam turbine to generate an additional 132MW of power. Internal process power consumption is approximately 62MW, and includes power for coal grinding, air separation, and feed pumps. Net output from the IGCC demonstration plant will be 260MW.

  3. Coordinated Control Scheme of Battery Energy Storage System (BESS) and Distributed Generations (DGs) for Electric Distribution Grid Operation

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Zhao, Haoran; Wu, Qiuwei

    2012-01-01

    This paper describes a coordinated control scheme of battery energy storage system (BESS) and distributed generations (DGs) for electric distribution grid operation. The BESS is designed to stabilize frequency and voltages as a primary control after the electric distribution system enters...... into the islanding operation mode, while the centralized joint load frequency control (CJLFC) utilizing DGs handles the secondary frequency regulation. The BESS with the associated controllers has been modelled in Real-time digital simulator (RTDS) in order to identify the improvement of the frequency and voltage...

  4. State Electricity Regulatory Policy and Distributed Resources: Distributed Resource Distribution Credit Pilot Programs--Revealing the Value to Consumers and Vendors

    Energy Technology Data Exchange (ETDEWEB)

    Moskovitz, D.; Harrington, C.; Shirley, W.; Cowart, R.; Sedano, R.; Weston, F.

    2002-10-01

    Designing and implementing credit-based pilot programs for distributed resources distribution is a low-cost, low-risk opportunity to find out how these resources can help defer or avoid costly electric power system (utility grid) distribution upgrades. This report describes implementation options for deaveraged distribution credits and distributed resource development zones. Developing workable programs implementing these policies can dramatically increase the deployment of distributed resources in ways that benefit distributed resource vendors, users, and distribution utilities. This report is one in the State Electricity Regulatory Policy and Distributed Resources series developed under contract to NREL (see Annual Technical Status Report of the Regulatory Assistance Project: September 2000-September 2001, NREL/SR-560-32733). Other titles in this series are: (1) Accommodating Distributed Resources in Wholesale Markets, NREL/SR-560-32497; (2) Distributed Resources and Electric System Re liability, NREL/SR-560-32498; (3) Distribution System Cost Methodologies for Distributed Generation, NREL/SR-560-32500; (4) Distribution System Cost Methodologies for Distributed Generation Appendices, NREL/SR-560-32501.

  5. Structural behaviour of concrete poles used in electric's power distribution network

    Directory of Open Access Journals (Sweden)

    Mehran Zeynalian

    2017-12-01

    Full Text Available Based on a preliminary study on regional electric companies, it is shown that there is no precise structural design on the concrete poles. This leads to uneconomical and overestimated networks’ components. Therefore, this study was aimed to investigate the lateral performance of the concrete poles which are employed in electric’s power distribution network. This paper presents a numerical study on structural performance of 12 m concrete poles used in electric’s power distribution network using Abaqus software. A sensitivity study for mesh size is carried out and concrete damaged plasticity has been employed. The results show that relatively coarse mesh (average in damaged concrete method gives more reliable result. Some experimental tests based on the Iranian standards were performed in order to make a bench mark for numerical output. Comparison between numerical and experimental results indicates a good agreement between the results. The outcomes also suggest that while the applied lateral load is less than around 400 kg which is assumed as the nominal resistance of the pole, no transverse crack occurs. Based on both experimental and numerical results, one or two transverse cracks are reported when the applied force reaches up to 600 kg. The rate of cracks is amplified by increasing the applied force; and finally, the pole would lose its capacity when the load rises much more than 1200 kg. The study also shows that the poles are very weak when the load direction changes. Also, it can be concluded that the final strength of the pole is higher than what the standards recommend. Finally, seismic behavior factor of the poles around both main axes are evaluated. The estimated seismic resistance factor for the concrete poles indicates that the prescribed R factor for such structure is relatively low; and can be improved at least 20%.

  6. A probabilistic methodology for distributed generation location in isolated electrical service area

    Energy Technology Data Exchange (ETDEWEB)

    Khodr, H.M.; Silva, Marco R.; Vale, Zita; Ramos, Carlos [GECAD - Knowledge Engineering and Decision-Support Research Center of the Polytechnic Institute of Porto (ISEP/IPP), Rua Dr. Antonio Bernardino de Almeida 431, 4200-072 Porto (Portugal)

    2010-04-15

    Distributed generation unlike centralized electrical generation aims to generate electrical energy on small scale as near as possible to load centers, interchanging electric power with the network. This work presents a probabilistic methodology conceived to assist the electric system planning engineers in the selection of the distributed generation location, taking into account the hourly load changes or the daily load cycle. The hourly load centers, for each of the different hourly load scenarios, are calculated deterministically. These location points, properly weighted according to their load magnitude, are used to calculate the best fit probability distribution. This distribution is used to determine the maximum likelihood perimeter of the area where each source distributed generation point should preferably be located by the planning engineers. This takes into account, for example, the availability and the cost of the land lots, which are factors of special relevance in urban areas, as well as several obstacles important for the final selection of the candidates of the distributed generation points. The proposed methodology has been applied to a real case, assuming three different bivariate probability distributions: the Gaussian distribution, a bivariate version of Freund's exponential distribution and the Weibull probability distribution. The methodology algorithm has been programmed in MATLAB. Results are presented and discussed for the application of the methodology to a realistic case and demonstrate the ability of the proposed methodology for efficiently handling the determination of the best location of the distributed generation and their corresponding distribution networks. (author)

  7. Distributed Energy Alternative to Electrical Distribution Grid Expansion in Consolidated Edison Service Territory

    Energy Technology Data Exchange (ETDEWEB)

    Kingston, Tim [Gas Technology Institute; Kelly, John [Endurant Energy LLC

    2008-08-01

    The nation's power grid, specifically the New York region, faces burgeoning energy demand and suffers from congested corridors and aging equipment that cost New York consumers millions of dollars. Compounding the problem is high-density buildup in urban areas that limits available space to expand grid capacity. Coincidently, these urban areas are precisely where additional power is required. DER in this study refers to combined heat and power (CHP) technology, which simultaneously generates heat and electricity at or near the point where the energy will be consumed. There are multiple CHP options available that, combined with a portfolio of other building energy efficiency (EE) strategies, can help achieve a more efficient supply-demand balance than what the grid can currently provide. As an alternative to expanding grid capacity, CHP and EE strategies can be deployed in a flexible manner at virtually any point on the grid to relieve load. What's more, utilities and customers can install them in a variety of potentially profitable applications that are more environmentally friendly. Under the auspices of the New York State Energy Research and Development Authority (NYSERDA) and the Oak Ridge National Laboratory representing the Office of Electricity of the U.S. Department of Energy, Gas Technology Institute (GTI) conducted this study in cooperation with Consolidated Edison to help broaden the market penetration of EE and DER. This study provides realistic load models and identifies the impacts that EE and DER can have on the electrical distribution grid; specifically within the current economic and regulatory environment of a high load growth area of New York City called Hudson Yards in Midtown Manhattan. These models can be used to guide new policies that improve market penetration of appropriate CHP and EE technologies in new buildings. The following load modeling scenarios were investigated: (1) Baseline: All buildings are built per the Energy

  8. Losses and unpaid bills in the electricity distribution activities in Brazil; Perdas e inadimplencia na atividade de distribuicao de energia eletrica no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Antonio Carlos Marques de

    2007-04-15

    The main purpose of this paper is to deepen the discussion about the impact of the electrical losses and the unpayment of the correspondent bills in the Brazilian market of electricity distribution, by establishing the dimension of the problem and analysing the main physical, economic and social variables which explain the rambling occurrence of the phenomenon among the companies all over the country. The study was developed by using statistical models which made possible to built explaining models. Furthermore, the paper discusses the institutional treatment given to the issue by the Brazilian federal regulatory agency, under a tariff, technical and regulatory point, and comments the actions adopted by the companies to minimize the consequent revenue impact. Finally, conclusions and some suggestions are presented regarding complementary studies related to this field of knowledge. (author)

  9. Global capacity announcement of electrical distribution systems: A pragmatic approach

    OpenAIRE

    Cornélusse, Bertrand; Vangulick, David; Glavic, Mevludin; Ernst, Damien

    2015-01-01

    We propose a pragmatic procedure to facilitate the connection process of Distributed Generation (DG) with reference to the European regulatory framework where Distribution System Operators (DSOs) are, except in specific cases, not allowed to own their generation. The procedure is termed Global Capacity ANnouncement (GCAN) and is intended to compute the estimates of maximum generation connection amount at appropriate substations in a distribution system, to help generation connection decisions...

  10. Potential Use of Communications and Project Management Systems in Remote Construction Projects: The Case of Saudi Electric Company

    Directory of Open Access Journals (Sweden)

    Bhzad Sidawi

    2012-01-01

    Full Text Available Remote projects have their unique problems that are caused mainly by the remoteness of the project itself thus the loose control over management. This is due to a number of reasons such as lack of human resources and infrastructure. Research studies that were undertaken worldwide - regarding this issue- has highlighted few unique management problems. The aim of this paper is to investigate how far the IT tools would help in managing remote construction projects in the Kingdom of Saudi Arabia (KSA. Due to the lack of previous research regarding remote projects within the Gulf region and the KSA, a pilot study was conducted in 2009 to define and test the wording of questions that are part of the main survey. The main survey was undertaken on Saudi Electric Company (SEC. The study found that IT systems and tools have the potential but this potential is hindered by a number of technical, managerial, staff factors. Therefore, successful application of IT systems would require changes to the present management settings at various levels. This would ensure that the SEC is capable of achieving the full benefit from using these advanced systems.

  11. Role Of E-Government In Delivery Of Public Services In Tanzania Electric Supply Company In Ruvuma Region Tanzania

    Directory of Open Access Journals (Sweden)

    Emmanuel Jackson Petro Gunda

    2015-06-01

    Full Text Available ABSTRACT E-government facilitates delivery of public services of relevant government information in electronic form to citizens in a timely manner and better service delivery to citizens. E-government is a kind of governmental administration which is based on Information Communication and Technology Services. Electronic government describes the use of technologies to facilitate the operation of government and disperse of government information and services. The scope of the work was limited to Tanzania Electric Supply Company Limited TANESCO in Ruvuma region. The population of thirty 31 were selected from a total population of 169 public servants use both purposive and stratified random sampling techniques applied. The major findings of study revealed that about 67.7 of response from respondents agree that ICT infrastructures specifically modern computer connected to internet reliable internet speed well organized organization website power availability in public operation contribute to efficient in delivery of services it also noted by respondents to faster decision making speeding up transaction processing and reduce cost. The study greatly recommends that capacity building to public servants on ICT install and strengthening ICT infrastructures to government organizational are inevitable to realise relevant role of e-government in delivery of public services.

  12. Congestion management of electric distribution networks through market based methods

    DEFF Research Database (Denmark)

    Huang, Shaojun

    Rapidly increasing share of intermittent renewable energy production poses a great challenge of the management and operation of the modern power systems. Deployment of a large number of flexible demands, such as electrical vehicles (EVs) and heat pumps (HPs), is believed to be a promising solution...

  13. modeling and optimization of an electric power distribution network

    African Journals Online (AJOL)

    user

    distribution systems including distributed generation. A constructive heuristic algorithm (CHA) is proposed in [5] for the EDNEPP. In that work, the binary decision variables of the mixed binary integer non-linear problem. (MBINLP) are relaxed making the problem a nonlinear programming (NLP) problem. The NLP problem is ...

  14. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  15. El Paso Electric Company Diablo Substation to the US-Mexico border 115kV transmission line project. Final Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    This Environmental Assessment documents the analysis of alternative corridors for development and operation of a proposed 115 kilovolt transmission line using private lands and transporting power to the US-Mexico international border. The project will require (1) an amendment to El Paso Electric Company`s existing export authorization to transfer power across this border, and (2) a Presidential Permit for construction of the transmission line. The project would be located in Dona Ana county in southern New Mexico, approximately five miles west of El Paso, Texas. The alternative corridors, specific locations within those corridors, and structure types are identified and analyzed in the environmental studies.

  16. Investigative Research, FMECA and PHM Modeling of Hybrid-Electric Distributed Propulsion System Architectures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Hybrid-Electric distributed propulsion (HEDP) is becoming widely accepted and new tools will be required for future development with validation and demonstrations...

  17. Distributed Coordination of Electric Vehicle Charging in a Community Microgrid Considering Real-Time Price

    DEFF Research Database (Denmark)

    Li, Chendan; Schaltz, Erik; Quintero, Juan Carlos Vasquez

    2016-01-01

    The predictable increasing adoption of EV by residential users imposes the necessity of Electric Vehicle charging coordination, in order to charge effectively while minimizing the impact on the grid. In this paper, a two-stage distributed coordination algorithm for electric vehicle charging...

  18. Electrical Power Transmission and Distribution Safety. Module SH-40. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on electrical power transmission and distribution safety is one of 50 modules concerned with job safety and health. This module focuses on some of the general safety rules, techniques, and procedures that are essential in establishing a safe environment for the electrical power transmission worker. Following the introduction,…

  19. CAPM (Capital Asset Pricing Model) and regulation in Brazilian electric distribution sector; CAPM (Capital Asset Pricing Model) e regulacao no segmento de distribuicao do setor eletrico brasileiro

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Rinaldo Caldeira; Parente, Virginia [Universidade de Sao Paulo (USP), SP (Brazil)], emails: rinaldo@iee.usp.br, vparente@iee.usp.br

    2010-07-01

    The aim of this paper is to analyse the use of Capital Asset Pricing Model (CAPM) Beta in the Brazilian electric distribution sector tariffs review. The betas applied by the Regulatory Agency are defined using data from the American, English and Brazilian markets. These betas will then be compared to the betas obtained in the domestic market. The betas were directly obtained from an economic-financial databank largely employed by the market. The sample is composed of companies' shares, priced at Sao Paulo Stock Market. Their main activity is the distribution of electric energy between July 2002 and July 2007. The results of mean betas obtained for the distribution segment, with values close to the ones applied by the regulatory agency for the cycle of tariff reviews between 2007-2010. (author)

  20. Impacts of electric vehicle charging on distribution networks in Denmark

    OpenAIRE

    Xu, Lizhong; Yang, Guang Ya; Xu, Zhao; Marra,Francesco; Træholt, Chresten

    2011-01-01

    Electric vehicles (EVs) provide a unique opportunity to reduce carbon dioxide emissions from the transport sector by drawing on renewable resources. As EVs become increasingly popular in the automotive market, the study of its impacts on the low-voltage grid has become increasingly important. The model of EVs is affected by the user, battery characteristics, as well as the environment. Studies are carried out based on the Danish case. A preliminary model on demand is created by integrating th...

  1. Increasing the capacity of distributed generation in electricity networks by intelligent generator control

    OpenAIRE

    Aristides E. Kiprakis

    2005-01-01

    The rise of environmental awareness as well as the unstable global fossil fuel market has brought about government initiatives to increase electricity generation from renewable energy sources. These resources tend to be geographically and electrically remote from load centres. Consequently many Distributed Generators (DGs) are expected to be connected to the existing Distribution Networks (DNs), which have high impedance and low X/R ratios. Intermittence and unpredictability of the vario...

  2. Electricity distribution industry restructuring, electrification, and competition in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Galen, P S

    1997-07-01

    This paper reviews the status of the South African electricity supply industry (ESI) and proposals for reorienting and restructuring it. South Africa has been intensely examining its ESI for more than 4 years in an effort to determine whether and how it should be restructured to best support the country`s new economic development and social upliftment goals. The debate has been spirited and inclusive of most ESI stakeholders. The demands on and expectations for the ESI are many and varied. The debate has reflected this diversity of interests and views. In essence, however, there is a consensus on what is expected of the industry, namely, to extend provision of adequate, reliable, and affordable electricity service to all citizens and segments of the economy. This means a large-scale electrification program to reach as many of the nearly 50% of households currently without electricity service as soon as possible, tariff reform to promote equity and efficiency, and the upgrading of service quality now being provided by some of the newly consolidated municipal authorities. The issues involved are how best to achieve these results within the context of the national Reconstruction and Development Program, while accounting for time and resource constraints and balancing the interests of the various parties.

  3. Electric-Field-Controlled Dopant Distribution in Organic Semiconductors.

    Science.gov (United States)

    Müller, Lars; Rhim, Seon-Young; Sivanesan, Vipilan; Wang, Dongxiang; Hietzschold, Sebastian; Reiser, Patrick; Mankel, Eric; Beck, Sebastian; Barlow, Stephen; Marder, Seth R; Pucci, Annemarie; Kowalsky, Wolfgang; Lovrincic, Robert

    2017-08-01

    Stable electrical doping of organic semiconductors is fundamental for the functionality of high performance devices. It is known that dopants can be subjected to strong diffusion in certain organic semiconductors. This work studies the impact of operating conditions on thin films of the polymer poly(3-hexylthiophene) (P3HT) and the small molecule Spiro-MeOTAD, doped with two differently sized p-type dopants. The negatively charged dopants can drift upon application of an electric field in thin films of doped P3HT over surprisingly large distances. This drift is not observed in the small molecule Spiro-MeOTAD. Upon the dopants' directional movement in P3HT, a dedoped region forms at the negatively biased electrode, increasing the overall resistance of the thin film. In addition to electrical measurements, optical microscopy, spatially resolved infrared spectroscopy, and scanning Kelvin probe microscopy are used to investigate the drift of dopants. Dopant mobilities of 10-9 to 10-8 cm2 V-1 s-1 are estimated. This drift over several micrometers is reversible and can be controlled. Furthermore, this study presents a novel memory device to illustrate the applicability of this effect. The results emphasize the importance of dynamic processes under operating conditions that must be considered even for single doped layers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. EDISON - research programme on electricity distribution automation 1993-1997. Interim report 1996

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M. [ed.] [VTT Energy, Espoo (Finland). Energy Systems

    1997-12-31

    The report comprises a summary of the results of the first four years of the research programme EDISON on distribution automation in Finnish utilities. The five year research programme (1993-1997) is conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of the funding is from the Technology Development Centre TEKES and from manufacturing companies. The goal of the research programme is to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer associated automation functions. In addition, the techniques for demand side management are developed and integrated into the automation scheme. The final aim is to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of fifteen projects are now given. These results should be considered intermediate, since most projects will be continued in 1997. (orig.) 43 refs.

  5. EDISON - research programme on electric distribution automation 1993-1997. Final report 1997

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M. [ed.] [VTT Energy, Espoo (Finland). Energy Systems

    1998-08-01

    This report comprises a summary of the results of the five year research programme EDISON on distribution automation in Finnish utilities. The research programme (1993 - 1997) was conducted under the leadership of VTT Energy, in cooperation with universities, distribution companies and the manufacturing industry. The main part of the funding has been from the Technology Development Centre TEKES and from manufacturing companies. The goal of the research programme was to develop a new scheme for a complete distribution automation system, including the network automation, computer systems in the control centre and the customer associated automation functions. In addition, the techniques for demand side management were developed and integrated into the automation scheme. The final aim was to demonstrate the automation functions and systems of the scheme in real distribution systems. The results of nineteen projects are given in this report

  6. The integration of renewable energy sources into electric power distribution systems. Volume 1: National assessment

    Science.gov (United States)

    Barnes, P. R.; Vandyke, J. W.; Tesche, F. M.; Zaininger, H. W.

    1994-06-01

    Renewable energy technologies such as photovoltaic, solar thermal electricity, and wind turbine power are environmentally beneficial sources of electric power generation. The integration of renewable energy sources into electric power distribution systems can provide additional economic benefits because of a reduction in the losses associated with transmission and distribution lines. Benefits associated with the deferment of transmission and distribution investment may also be possible for cases where there is a high correlation between peak circuit load and renewable energy electric generation, such as photovoltaic systems in the Southwest. Case studies were conducted with actual power distribution system data for seven electric utilities with the participation of those utilities. Integrating renewable energy systems into electric power distribution systems increased the value of the benefits by about 20 to 55% above central station benefits in the national regional assessment. In the case studies presented in Vol. 2, the range was larger: from a few percent to near 80% for a case where costly investments were deferred. In general, additional savings of at least 10 to 20% can be expected by integrating at the distribution level. Wind energy systems were found to be economical in good wind resource regions, whereas photovoltaic systems costs are presently a factor of 2.5 too expensive under the most favorable conditions.

  7. The integration of renewable energy sources into electric power distribution systems. Volume 1: National assessment

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, P.R.; Van Dyke, J.W. [Oak Ridge National Lab., TN (United States); Tesche, F.M. [6714 Norway Road, Dallas, TX (United States); Zaininger, H.W. [Zaininger Engineering Co., San Jose, CA (United States)

    1994-06-01

    Renewable energy technologies such as photovoltaic, solar thermal electricity, and wind turbine power are environmentally beneficial sources of electric power generation. The integration of renewable energy sources into electric power distribution systems can provide additional economic benefits because of a reduction in the losses associated with transmission and distribution lines. Benefits associated with the deferment of transmission and distribution investment may also be possible for cases where there is a high correlation between peak circuit load and renewable energy electric generation, such as photovoltaic systems in the Southwest. Case studies were conducted with actual power distribution system data for seven electric utilities with the participation of those utilities. Integrating renewable energy systems into electric power distribution systems increased the value of the benefits by about 20 to 55% above central station benefits in the national regional assessment. In the case studies presented in Vol. II, the range was larger: from a few percent to near 80% for a case where costly investments were deferred. In general, additional savings of at least 10 to 20% can be expected by integrating at the distribution level. Wind energy systems were found to be economical in good wind resource regions, whereas photovoltaic systems costs are presently a factor of 2.5 too expensive under the most favorable conditions.

  8. Research on electric field distribution of UHVDC transmission lines and body surface during live working

    Science.gov (United States)

    Jiang, Chilong; Zou, Dehua; Li, Jinliang; Zhang, Zhanlong; Mei, Daojun

    2017-09-01

    Electric field distortion emerges around personnel working on live Ultra High Voltage Direct Current UHVDC transmission lines, especially when they move from ground-potential to equipotential positions. Unreliable protection threatens the safety of both workers and transmission lines. The current study investigates the electric field distribution of body surface during live working under transmission lines. To provide safety advice, live working person and tower models were established. The body surface field was calculated in different positions under ±800 kV transmission lines, and the distribution of the electric field was summarized.

  9. A distributed transducer system for functional electrical stimulation

    DEFF Research Database (Denmark)

    Gudnason, Gunnar; Nielsen, Jannik Hammel; Bruun, Erik

    2001-01-01

    Implanted transducers for functional electrical stimulation (FES) powered by inductive links are subject to conflicting requirements arising from low link efficiency, a low power budget and the need for protection of the weak signals against strong RF electromagnetic fields. We propose a solution...... to be affected by the inductive link. Neural stimulators are affected to a lesser degree, but still benefit from the partitioning. As a test case, we have designed a transceiver and a sensor chip which implement this partitioning policy. The transceiver is designed to operate in the 6.78 MHz ISM band...

  10. Multi-agent based modeling for electric vehicle integration in a distribution network operation

    DEFF Research Database (Denmark)

    Hu, Junjie; Morais, Hugo; Lind, Morten

    2016-01-01

    operator (DSO) technical agent and ii) DSO market agents that both belong to the top layer of the hierarchy and their roles are to manage the distribution network by avoiding grid congestions and using congestion prices to coordinate the energy scheduled; iii) Electric vehicle virtual power plant agents...... are in the middle level of the hierarchy and their roles are to manage the charge process of the electric vehicles; iv) Electric vehicle agents are placed at the bottom layer of the hierarchy and they represent electric vehicle owners with different users’ profiles. To demonstrate the coordination behavior...

  11. Strategy-making for a proactive distribution company in the real-time market with demand response

    DEFF Research Database (Denmark)

    Zhang, Chunyu; Wang, Qi; Wang, Jianhui

    2016-01-01

    This paper proposes a methodology to optimize the trading strategies of a proactive distribution company (PDISCO) in the real-time market by mobilizing the demand response. Each distribution-level demand is considered as an elastic one. To capture the interrelation between the PDISCO and the real......-time market, a bi-level model is presented for the PDISCO to render continuous offers and bids strategically. The upper level problem expresses the PDISCO's profit maximization, while the lower-level problem minimizes the operation cost of the transmission-level real-time market. To solve the proposed model......, a primal-dual approach is used to translate this bi-level model into a single-level mathematical program with equilibrium constraints. Results of case studies are reported to show the effectiveness of the proposed model. (C) 2016 Elsevier Ltd. All rights reserved....

  12. Working conditions and psychosocial risk factors of employees in French electricity and gas company customer support departments.

    Science.gov (United States)

    Chevalier, Anne; Dessery, Michel; Boursier, Marie-Françoise; Grizon, Marie Catherine; Jayet, Christian; Reymond, Catherine; Thiebot, Michelle; Zeme-Ramirez, Monique; Calvez, Thierry

    2011-01-01

    Little is known about the real impact of working conditions on the health of call center employees. The aim of this article is to describe the working conditions of French electricity and gas company customer service teams, especially those spending more than 75% of their working time handling calls in order to determine their subjective experience of their work and identify situations at risk of psychosocial constraints. A cross-sectional study using a self-completion questionnaire was conducted on a representative sample of 2,000 employees working in customer service centers. The questions focused on the variety of tasks performed, the organization of working time, the physical environment of the workstation, violent situations and psychosocial factors (Job Content Questionnaire). Multivariate statistical analyses were performed to identify factors associated with the wish to leave the sector and with a high level of psychosocial constraints. Women made up 66% of the sample. Despite a high educational level, the average socio-professional level of the employees was relatively low. Although the vast majority of employees had chosen this career (74%), just over half would like to leave. The main factors associated with iso-strain were inadequate breaks (odds ratio (OR) = 2.0), low perceived quality of work (OR = 2.4), high proportion of working time spent handling calls (≥75% of working time: OR = 5.9, between 50 and violence either internally (often or very often: OR = 3.1) or from customers (often or very often: OR = 1.8) and an unsatisfactory workplace (OR = 2.0). Employees who spend more than 75% of their working time on the phone cumulate every factor linked with a high level of constraints, but all employees of the EDF and Gaz de France customer service centers are concerned. These workers share many characteristics with other call centers: predominantly female workforce; high educational level; wish to leave this sector despite the initial choice; high

  13. Stratum Electricity Markets: Toward Multi-temporal Distributed Risk Management for Sustainable Electricity Provision

    Science.gov (United States)

    Wu, Zhiyong (Richard)

    Motivated by the overall challenge of ensuring long-term sustainable electricity service, we view this challenge as a long-term decision making problem under uncertainties. We start by recognizing that, independent of the industry organization, the uncertainties are enormous and often exogenous to the energy service providers. They are multi-dimensional and are result of fundamental drivers, ranging from the supply side, through the demand side, to the regulatory and policy sides. The basic contribution of this thesis comes from the recognition that long-term investments for ensuring reliable and stable electricity service critically depend on how these uncertainties are perceived, valued and managed by the different stakeholders within the complex industry organization such as the electric power industry. We explain several reasons why price signals obtained from current short-term electricity markets alone are not sufficient enough for long-term sustainable provision. Some enhancements are presented in the thesis to improve the short-term electricity market price signals to reflect the true cost of operation. New market mechanisms and instruments are needed to facilitate the stakeholders to better deal with long-term risks. The problems of ensuring long-term stable reliable service in the sense of the traditional resource adequacy requirements are revisited in both the restructuring industry and regulated industry. We introduce a so-called Stratum Electricity Market (SEM) design as the basic market mechanism for solving the problem of long-term reliable electricity service through a series of interactive multi-lateral market exchange platforms for risks communication, management and evaluations over various time horizons and by the different groups of stakeholders. In other words, our proposed SEM is a basic IT-enabled framework for the decision making processes by various parties over different time. Because of the uniqueness of electricity as a commodity, the

  14. Using SOA and WEB Services for an Electricity Distribution Enterprise

    Directory of Open Access Journals (Sweden)

    Radu-Ştefan MOLEAVIN

    2012-01-01

    Full Text Available A viable enterprise today must adapt continously to the requirements of the market. The adaptation of a company to the market requirements means also changes of business processes within IT systems. In any enterprise there is a strong link between business processes and IT applications IT and a business process modification will determine a modification in the IT applications. In order to increase the alignment between business and IT and achieve business agility – the ability to respond to changes quickly and efficiency – we have to create a flexible mechanism between IT applications and business processes which will make that the adaptation to the market changes will be made quickly and with low consumption of either human or material resources. Therefore, enterprises need agility to maintain strategic advantages in operating businesses. Service Oriented Architecture (SOA represents an architectural design which provide agility and satisfies the business processes in order to achieve business agility. In the IT area, SOA promises to reduce application development and maintenance costs through service reuse. A service may be considered as a set of components and software operations which are built in a way that permit them to be flexibly and dynamically integrated to cover both IT and business needs. SOA offers capabilities for the services to be combined together, to support and create a flexible and agile enterprise.

  15. Intelligent system to control electric power distribution networks

    Directory of Open Access Journals (Sweden)

    Pablo CHAMOSO

    2016-07-01

    Full Text Available The use of high voltage power lines transport involves some risks that may be avoided with periodic reviews as imposed by law in most countries. The objective of this work is to reduce the number of these periodic reviews so that the maintenance cost of power lines is also reduced. To reduce the number of transmission towers (TT to be reviewed, a virtual organization (VO based system of agents is proposed in conjunction with different artificial intelligence methods and algorithms. This system is able to propose a sample of TT from a selected set to be reviewed and to ensure that the whole set will have similar values without needing to review all the TT. As a result, the system provides a software solution to manage all the review processes and all the TT of Spain, allowing the review companies to use the application either when they initiate a new review process for a whole line or area of TT, or when they want to place an entirely new set of TT, in which case the system would recommend the best place and the best type of structure to use.

  16. Proposal of an Innovative Electric Power Distribution System based on Packet Power Transactions

    Science.gov (United States)

    Inoue, Jun; Fujii, Yasumasa

    Recently, the introduction of decentralized generators, such as photovoltaic power generations, has been promoted rapidly. In the future, extensive use of PV is thought to give rise to the daytime surplus electricity, and a household will manage the surplus electricity rationally. The purpose of this research is to propose an innovative electric power distribution system based on packet power transactions. First, this paper explains distributed markets of which the price can easily reflect the geographical diversity of renewable energy availability and load curve characteristic within the local area. Second, this paper exemplifies the specific electronic circuit that makes pulse-shaped power transmission to develop the packet power distribution system. Finally, this paper shows the results of multi-agent simulations of electricity trading to evaluate the usefulness of the proposed system.

  17. Proceedings of the electricity distribution information systems and technology conference : smart technology : evolution or revolution

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This conference provided a forum for electric utility operators, electrical engineers, and IT professionals to discuss smart technology applications for managing electrical supply and distribution. Recent advances in 3-D visualization and smart grid technologies were discussed as well as issues related to ethernet networks and grid intelligence technologies. Developments in virtualization and their potential applications in the electric power industry were evaluated. Distribution automation innovations were reviewed. Technical challenges related to the recent growth in distributed generation connections were also discussed, as well as electronic records management and cyber security strategies. Smart meters and home energy network innovations were presented. Other topics included meter data management techniques, design considerations for control centres, and the development of data stores for smart meters. The conference featured 23 presentations, of which 4 have been catalogued separately for inclusion in this database. tabs., figs.

  18. [Optimization of electrode location and size on simulation in electric field distribution of atrial defibrillation].

    Science.gov (United States)

    Wang, Cong; Yang, Shengjun; Zheng, Yi; Wu, Xiaomei; Wang, Qunshan; Wei, Daming

    2014-03-01

    A distributed simulation method of electric field based on the atrial defibrillation of the heart modeling and finite element solution is proposed in this study. In order to solve the problem that ordinary clinical trials could not measure the actual distribution of the defibrillation electric field in the heart accurately, this method provides a research tool for electrical defibrillation. A complete atrial anatomical structure in the heart model is used in the research, the finite element method is proceeded to solve; Three parameters: defibrillation threshold voltage, the high field strength rate and the defibrillation threshold energy are set to evaluate the effect of defibrillation. The heart electric field distributions of transvenous atrial defibrillation with different electrode locations or sizes are simulated. The simulation results and the reported results match fairly well, which initially verify the feasibility of this method.

  19. Assessing the Operational Resilience of Electrical Distribution Systems

    Science.gov (United States)

    2017-09-01

    improvements. Carnal (2005) further improves on VEGA by inclusion of the Xpres-MP software package, reducing run-time by 65% - 85%. Schneider (2005) performs... disable part of the distribution system being analyzed. At present, the data itself needs to be modified to break a line or disable a substation. An

  20. Current Electric Distribution Network Operation and Grid Tariffs

    DEFF Research Database (Denmark)

    Wu, Qiuwei

    2012-01-01

    The aim of EcoGridEU task 1.4 is to extend the real‐time price approach with an integrated optimization of the distribution system operation. This will be achieved by extending the basic real‐time market concept with local location‐dependant prices that reflect the grid operation, especially the ...

  1. Controlling electrical power losses in transmission and distribution ...

    African Journals Online (AJOL)

    ... undertaking regular energy audit and implementing pre-paid meter-ing systems. The policies on deterring energy theft, meter tampering, fully accounting for energy generated and distributed and strategic marketing of power should be enforced. The re-branding of the Power Holding Comp-pany of Nigeria for satisfactory ...

  2. Multi-objective optimization control of plug-in electric vehicles in low voltage distribution networks

    DEFF Research Database (Denmark)

    García-Villalobos, J.; Zamora, I.; Knezovic, Katarina

    2016-01-01

    The massive introduction of plug-in electric vehicles (PEVs) into low voltage (LV) distribution networks will lead to several problems, such as: increase of energy losses, decrease of distribution transformer lifetime, lines and transformer overload issues, voltage drops and unbalances. In this c...

  3. Electric field of a 2D elliptical charge distribution inside a cylindrical conductor

    Directory of Open Access Journals (Sweden)

    Miguel A. Furman

    2007-08-01

    Full Text Available By combining the method of images with calculus of complex variables, we provide a simple expression for the electric field of a two-dimensional (2D static elliptical charge distribution inside a perfectly conducting circular cylinder. The charge distribution need not be concentric with the cylinder.

  4. Recursive Estimation of π-Line Parameters for Electric Power Distribution Grids

    DEFF Research Database (Denmark)

    Prostejovsky, Alexander; Gehrke, Oliver; Kosek, Anna Magdalena

    2016-01-01

    Electrical models of power distribution grids are used in applications such as state estimation and Optimal Power Flow (OPF), the reliability of which depends on the accuracy of the model. This work presents an approach for estimating distribution line parameters from Remote Terminal Unit (RTU...

  5. Summary of Electric Distribution System Analyses with a focus on DERs

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yingying [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Homer, Juliet S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McDermott, Thomas E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coddington, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sigrin, Benjamin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mather, Barry [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-04-28

    The purpose of this document is to summarize types of electric distribution system analyses along with their application and relative maturity. Particular emphasis is placed on analyses associated with distributed energy resources (DERs). Analyses are separated into the categories of power flow, power quality, fault analysis, dynamic analysis and market analysis. Studies associated with DERs are called out in a separate section.

  6. Distribution Locational Marginal Pricing for Optimal Electric Vehicle Charging through Chance Constrained Mixed-Integer Programming

    DEFF Research Database (Denmark)

    Liu, Zhaoxi; Wu, Qiuwei; Oren, Shmuel S.

    2017-01-01

    This paper presents a distribution locational marginal pricing (DLMP) method through chance constrained mixed-integer programming designed to alleviate the possible congestion in the future distribution network with high penetration of electric vehicles (EVs). In order to represent the stochastic...

  7. The Value of Distributed Solar Electric Generation to San Antonio

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Nic [Solar San Antonio, TX (United States); Norris, Ben [Clean Power Research, Napa, CA (United States); Meyer, Lisa [City of San Antonio, TX (United States)

    2013-02-14

    This report presents an analysis of value provided by grid-connected, distributed PV in San Antonio from a utility perspective. The study quantified six value components, summarized in Table ES- 1. These components represent the benefits that accrue to the utility, CPS Energy, in accepting solar onto the grid. This analysis does not treat the compensation of value, policy objectives, or cost-effectiveness from the retail consumer perspective.

  8. Current density imaging sequence for monitoring current distribution during delivery of electric pulses in irreversible electroporation.

    Science.gov (United States)

    Serša, Igor; Kranjc, Matej; Miklavčič, Damijan

    2015-01-01

    Electroporation is gaining its importance in everyday clinical practice of cancer treatment. For its success it is extremely important that coverage of the target tissue, i.e. treated tumor, with electric field is within the specified range. Therefore, an efficient tool for the electric field monitoring in the tumor during delivery of electroporation pulses is needed. The electric field can be reconstructed by the magnetic resonance electric impedance tomography method from current density distribution data. In this study, the use of current density imaging with MRI for monitoring current density distribution during delivery of irreversible electroporation pulses was demonstrated. Using a modified single-shot RARE sequence, where four 3000 V and 100 μs long pulses were included at the start, current distribution between a pair of electrodes inserted in a liver tissue sample was imaged. Two repetitions of the sequence with phases of refocusing radiofrequency pulses 90° apart were needed to acquire one current density image. For each sample in total 45 current density images were acquired to follow a standard protocol for irreversible electroporation where 90 electric pulses are delivered at 1 Hz. Acquired current density images showed that the current density in the middle of the sample increased from first to last electric pulses by 60%, i.e. from 8 kA/m2 to 13 kA/m2 and that direction of the current path did not change with repeated electric pulses significantly. The presented single-shot RARE-based current density imaging sequence was used successfully to image current distribution during delivery of short high-voltage electric pulses. The method has a potential to enable monitoring of tumor coverage by electric field during irreversible electroporation tissue ablation.

  9. Improving delivery routes using combined heuristic and optimization in a consumer goods distribution company

    Science.gov (United States)

    Wibisono, E.; Santoso, A.; Sunaryo, M. A.

    2017-11-01

    XYZ is a distributor of various consumer goods products. The company plans its delivery routes daily and in order to obtain route construction in a short amount of time, it simplifies the process by assigning drivers based on geographic regions. This approach results in inefficient use of vehicles leading to imbalance workloads. In this paper, we propose a combined method involving heuristic and optimization to obtain better solutions in acceptable computation time. The heuristic is based on a time-oriented, nearest neighbor (TONN) to form clusters if the number of locations is higher than a certain value. The optimization part uses a mathematical modeling formulation based on vehicle routing problem that considers heterogeneous vehicles, time windows, and fixed costs (HVRPTWF) and is used to solve routing problem in clusters. A case study using data from one month of the company’s operations is analyzed, and data from one day of operations are detailed in this paper. The analysis shows that the proposed method results in 24% cost savings on that month, but it can be as high as 54% in a day.

  10. Grid-Aware Demand Management in Electricity Distribution Grids

    DEFF Research Database (Denmark)

    Bessler, Sanford; Kemal, Mohammed Seifu; Silva, Nuno

    2018-01-01

    prices. This paper presents an extended demand management approach that focuses on two aspects: (1) introduction of an interface to the Distribution System Operator in order to allow for grid load management (overload avoidance); (2) end-to-end robustness to changes of real-time information......, in particular addressing variable communication network behavior as it may result from the use of shared communication network infrastructure. The paper presents algorithms that realize such demand management on different levels in a hierarchical control system, defines and implements the related protocols...

  11. Electrical power transmission and distribution aging and life extension techniques

    CERN Document Server

    Chudnovsky, Bella H

    2012-01-01

    ""The focus of this unique reference book is four critical areas in the manufacturing of power distribution components. These areas are plating, lubrication, insulator failure, and maintenance. ... The many SEM images, x-ray studies, photos, and tabular data make for a very convenient reference source for diagnosing plating problems. ... Examples often help to drive home a point, and many case studies illustrating the various failure modes described throughout the book are included. These could prove to be an invaluable source of information when trying to diagnose unknown field failures. ...

  12. Electric power distribution. 7. rev. ed.; Elektrische Energieverteilung

    Energy Technology Data Exchange (ETDEWEB)

    Flosdorff, R. [Fachhochschule Aachen (Germany); Hilgarth, G. [Fachhochschule Braunschweig-Wolfenbuettel, Wolfenbuettel (Germany)

    2000-07-01

    This is the 7th revised edition of a 30-year-old standard textbook. There are some new chapters: Methods of calculating voltage drop, thermal capacity and short-circuit resistance; Types and dimensioning of overhead transmission lines and underground cables; Protection systems; Control systems; Power stations; Fundamentals of electric power supply. There is an appendix with units, bibliographic references, VDE regulations, characteristics of cables and supply lines, sysmbols and protective measures. [German] Die vorliegenden 7. Auflage des seit 30 Jahren bewaehrten Werkes wurde ueberarbeitet und aktualisiert. Die Struktur wurde beibehalten; jedoch wurden die modernen Rechenverfahren weiter ergaenzt. Der Studierende wird befaehigt, Leitungen und Netze hinsichtlich Spannungsabfall, thermischer Belastbarkeit und Kurzschlussfestigkeit zu dimensionieren, wobei auch oekologische Gesichtspunkte beruecksichtigt werden. Auf die Bauarten und die Bemessung von Freileitungen und Kabelanlagen einschliesslich der Hochleistungskabel wird eingegangen. Zur Schadensbegrenzung bei elektrischen Fehlern werden die erforderlichen und notwendigen Schutzeinrichtungen vorgestellt. Der Abschnitt ueber Schaltanlagen gibt einen Einblick in die Struktur der Geraetetechnik zur Versorgung mit elektrischer Energie. Die Kraftwerke als Quelle der elektrischen Energieversorgung werden im Ueberblick abgehandelt. Schliesslich werden Grundbegriffe der Elektrizitaetswirtschaft, die jeder Ingenieur der Elektrotechnik kennen sollte, erlaeutert. Auch dem in der Praxis stehenden Ingenieur kann deshalb dieses Buch ein wertvolles Hilfsmittel sein. Im Anhang kann der Leser Einheiten, Schrifttum, Normblaetter, VDE-Bestimmungen, Kenndaten von Kabeln und Leitungen, Schaltzeichen und Schutzmassnahmen nachschlagen. (orig.)

  13. Ex vivo and in silico feasibility study of monitoring electric field distribution in tissue during electroporation based treatments.

    Directory of Open Access Journals (Sweden)

    Matej Kranjc

    Full Text Available Magnetic resonance electrical impedance tomography (MREIT was recently proposed for determining electric field distribution during electroporation in which cell membrane permeability is temporary increased by application of an external high electric field. The method was already successfully applied for reconstruction of electric field distribution in agar phantoms. Before the next step towards in vivo experiments is taken, monitoring of electric field distribution during electroporation of ex vivo tissue ex vivo and feasibility for its use in electroporation based treatments needed to be evaluated. Sequences of high voltage pulses were applied to chicken liver tissue in order to expose it to electric field which was measured by means of MREIT. MREIT was also evaluated for its use in electroporation based treatments by calculating electric field distribution for two regions, the tumor and the tumor-liver region, in a numerical model based on data obtained from clinical study on electrochemotherapy treatment of deep-seated tumors. Electric field distribution inside tissue was successfully measured ex vivo using MREIT and significant changes of tissue electrical conductivity were observed in the region of the highest electric field. A good agreement was obtained between the electric field distribution obtained by MREIT and the actual electric field distribution in evaluated regions of a numerical model, suggesting that implementation of MREIT could thus enable efficient detection of areas with insufficient electric field coverage during electroporation based treatments, thus assuring the effectiveness of the treatment.

  14. Why don’t similar e-commerce companies choose similar logistics distribution system? : a case study of two e-commerce companies in China based on transaction cost theory

    OpenAIRE

    Chen, Wenjie

    2016-01-01

    During the last decade, the importance of “last mile delivery” has become increasingly prominent due to the booming development of e-commerce. Logistics services have become the bottleneck of the development of e-commerce in China. This thesis focuses on the research of self-built and outsourced logistics distribution system. The main research objective is to identify why two similar e-commerce companies have chosen different logistics distribution system In this study, two e-commer...

  15. Preliminary analysis of Block Island Power Company's use of clean distributed resources to provide power to its customers

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, T.E.

    2000-01-25

    This report is an analysis of the potential for Block Island Power Company (BIPCO) to use renewable energy and clean distributed resources to supply power to its customers. The preliminary conclusion of this work is that a system composed of clean distributed resources has the potential to be a technically and economically feasible alternative for BIPCO.

  16. Changes in mobile phase ion distribution when combining pressurized flow and electric field.

    Science.gov (United States)

    Eriksson, Björn O; Dahl, Magnus; Andersson, Magnus B O; Blomberg, Lars G

    2004-10-01

    The distribution of ions in a capillary with both pressurized flow and an electric field has been studied. We have earlier reported that the overall concentration of ions increase in a capillary with high electric field and a pressurized flow. Now we describe how the ions are distributed in the capillary both along the capillary length and in the radial direction as a result of the parabolic flow profile. We have combined current measurements with finite element techniques in order to get better understanding of the system. We have found that the concentration of the ions that because of the electric mobility moves towards the flow primarily increases at the beginning of the electric field and close to the capillary wall. In view of the results we have proposed an alterative explanation of earlier published results concerning voltage-induced variation in capacity factors. Copyright 2004 WILEY-VCH Verlag GmbH & Co.

  17. The new control system of the main load distributor of the combined Austrian electricity company. Das neue Leitsystem des Hauptlastverteilers der Oesterreichischen Verbundgesellschaft

    Energy Technology Data Exchange (ETDEWEB)

    Moik, J. (Hauptabteilung Informatik und Planungsmethoden, Oesterreichische Verbundgesellschaft, Vienna (Austria)); May, F. (Hauptabteilung Informatik und Planungsmethoden, Oesterreichische Verbundgesellschaft, Vienna (Austria)); Pollhammer, G. (Siemens AG, Vienna (Austria))

    1993-06-28

    The planning, production and setting to work of a complex system, as represented by an energy management system for a national load distributor, requires the use of modern project methods and close collaboration of energy supply firms, consultants and suppliers of this control system. In the case of the new control system of the combined Austrian company, prompt and within budget execution was achieved by the early involvement of all the departments concerned, by clear project organisation and distribution of competence between the two partners to the contract and by thorough use of quality assurance measures. The functioning of the new control system of the combined Austrian company is matched to the foreseeable requirements of operational management. Future new requirements can be integrated at any time into the load distribution system by the distributed flexible system design by Sinaut Spectrum. (orig.)

  18. The importance of market data for energy distribution companies. Marketing bij energiebedrijven; De rol van marktgegevens bij het bereiken van nieuwe doelstellingen

    Energy Technology Data Exchange (ETDEWEB)

    Frerejean, J.A.M. (Regionaal Energiebedrijf Dordrecht (Netherlands))

    1990-10-01

    The objective of a modern energy distribution company is not the mere supply of energy, but includes the conservation of energy and environmental protection as well. Such a company has to be customer-orientated and to be alert to market opportunities. The Dutch market situation is described. The available data on consumers and on their energy use are specified, and it is indicated how to make optimal use of these data. 12 ills.

  19. Divorce comes at a price: An ex ante welfare analysis of ownership unbundling of the distribution and commercial companies in the Dutch energy sector

    Energy Technology Data Exchange (ETDEWEB)

    Nooij, Michiel de, E-mail: m.denooij@seo.n [SEO Economic Research, Roetersstraat 29, 1018 WB, Amsterdam (Netherlands); Baarsma, Barbara [SEO Economic Research, Roetersstraat 29, 1018 WB, Amsterdam (Netherlands)

    2009-12-15

    Vertical unbundling in the electricity sector is a hot political topic in the European Union. The European Commission has decided that the ownership unbundling of transmission networks from other stages in the value chain is the most effective way to ensure fair network access and infrastructure investment. While this European unbundling debate has not ended yet and most countries still do not have an independent transmission system operator (TSO), the Dutch government has already taken one step further. In 2008, it decided that distribution companies should be completely separated from commercial activities that are part of the same holding (generation, trade and supply). This governmental decision has been fiercely debated. Although the goal is to improve competition as well as security of supply, these benefits are uncertain. Nevertheless, it is certain that ownership unbundling comes at a cost. In this paper we present an ex ante cost-benefit analysis of the Dutch unbundling act. We conclude that it is unlikely that this act is welfare enhancing: divorce comes at a price.

  20. Divorce comes at a price. An ex ante welfare analysis of ownership unbundling of the distribution and commercial companies in the Dutch energy sector

    Energy Technology Data Exchange (ETDEWEB)

    De Nooij, Michiel; Baarsma, Barbara [SEO Economic Research, Roetersstraat 29, 1018 WB, Amsterdam (Netherlands)

    2009-12-15

    Vertical unbundling in the electricity sector is a hot political topic in the European Union. The European Commission has decided that the ownership unbundling of transmission networks from other stages in the value chain is the most effective way to ensure fair network access and infrastructure investment. While this European unbundling debate has not ended yet and most countries still do not have an independent transmission system operator (TSO), the Dutch government has already taken one step further. In 2008, it decided that distribution companies should be completely separated from commercial activities that are part of the same holding (generation, trade and supply). This governmental decision has been fiercely debated. Although the goal is to improve competition as well as security of supply, these benefits are uncertain. Nevertheless, it is certain that ownership unbundling comes at a cost. In this paper we present an ex ante cost-benefit analysis of the Dutch unbundling act. We conclude that it is unlikely that this act is welfare enhancing: divorce comes at a price. (author)

  1. A Survey on Control of Electric Power Distributed Generation Systems for Microgrid Applications

    DEFF Research Database (Denmark)

    Bouzid, Allal; Guerrero, Josep M.; Cheriti, Ahmed

    2015-01-01

    The introduction of microgrids in distribution networks based on power electronics facilitates the use of renewable energy resources, distributed generation (DG) and storage systems while improving the quality of electric power and reducing losses thus increasing the performance and reliability...... of the electrical system, opens new horizons for microgrid applications integrated into electrical power systems. The hierarchical control structure consists of primary, secondary, and tertiary levels for microgrids that mimic the behavior of the mains grid is reviewed. The main objective of this paper is to give...... a description of state of the art for the distributed power generation systems (DPGS) based on renewable energy and explores the power converter connected in parallel to the grid which are distinguished by their contribution to the formation of the grid voltage and frequency and are accordingly classified...

  2. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....... charging capability in existing low voltage distribution feeders. The aim is to prevent the voltage to exceed the permitted values when charging at high power, by exploiting the effect of the reactive power. The proposed guidelines for distribution system operators are reported in a matrix, which indicates...

  3. Integration of Electric Vehicles into the Power Distribution Network with a Modified Capacity Allocation Mechanism

    DEFF Research Database (Denmark)

    Hu, Junjie; Morais, Hugo; Sousa, Tiago

    2017-01-01

    The growing penetration of electric vehicles (EVs) represents an operational challenge to system operators, mainly at the distribution level by introducing congestion and voltage drop problems. To solve these potential problems, a two-level coordination approach is proposed in this study....... An aggregation entity, i.e., an EV virtual power plant (EV-VPP), is used to facilitate the interaction between the distribution system operator (DSO) and EV owners considering the decentralized electricity market structure. In level I, to prevent the line congestion and voltage drop problems, the EV......-VPPs, considering the case of EVs charging and discharging. The three mechanisms include: (1) a market-based approach; (2) a pro-rata approach; and (3) a newly-proposed constrained market-based approach. A case study considering a 37-bus distribution network and high penetration of electric vehicles is presented...

  4. Detection and localization of changes in two-dimensional temperature distributions by electrical resistance tomography

    Science.gov (United States)

    Rashetnia, Reza; Hallaji, Milad; Smyl, Danny; Seppänen, Aku; Pour-Ghaz, Mohammad

    2017-11-01

    This paper studies the feasibility of applying electrical resistance tomography (ERT) to detect changes in two-dimensional (2D) temperature distributions with potential applications in sensor development. The proposed sensor consists of a thin layer of porous metal film manufactured by spraying colloidal copper paint to a solid surface. A change of the temperature distribution on the surface changes the 2D distributed electrical conductivity of the metal film. The change of the electrical conductivity is localized and quantified with ERT, and further, to convert the estimated conductivity change of the sensor to temperature change, an experimentally developed model is used. The proposed temperature sensor is evaluated experimentally by applying it to a polymeric substrate, and exposing it to known temperature changes using heat sources of different shapes. The results demonstrate that the proposed sensor is capable of detecting and localizing temperature changes, and provides at least qualitative information on the magnitude of the temperature change.

  5. Opportunities for Efficiency Improvements in the U.S. Electricity Transmission and Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Onar, Omer C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kirkham, Harold [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fisher, Emily [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Burkes, Klaehn [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Starke, Michael R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mohammed, Olama [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Weeks, George [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-01

    Since 2000, more than 172 quads of electricity have been transmitted on the US transmission and distribution (T&D) grid. Given this significant amount of energy flow, establishing and maintaining an efficient T&D grid is paramount. As shown in the figure below, the total percentage of overall losses in the US electric grid is approximately 6% (5.12% in 2012) (30% lower than the world average since 2000). While these efficiency losses appear to be relatively small from a percentage perspective, the total estimated electricity loss during this time is 10.8 quads.

  6. Flexible distributed control and protection system for industrial objects – Consumers of electric power

    Directory of Open Access Journals (Sweden)

    E.N. Alontseva

    2015-12-01

    Full Text Available Problems of efficient use of electric power and energy saving remain to be outstanding in our country. Implementation of smart systems for accounting and control of energy resources becomes the efficient solution of these problems. The problem of control and forecasting consumption of energy by the facility to cover internal needs represents an independent task. In general, systems are suggested which pertain to the control and accounting of energy resources supplied to the consumer of electric power. Approach to the development of system on the basis of concept of smart grids using dedicated complex of technical and software products allowing optimizing electric power expenditures, re-distributing electric power and promptly adjusting electric power grid characteristics is addressed in the present paper. Electric power supply control and monitoring devices receiving and transferring information to the server are installed in the places of connection of consumers to electric power supply grids. Server collects, accumulates and stores the information and is equipped with dedicated software allowing optimizing the load, preventing overloading and development of emergency situations within the electric power supply system. Such systems are suggested to be implemented by the facilities of nuclear industry.

  7. The French Electricity Company (EDF) and the environment. Press file for 1996; EDF et l'environnment 1996. Dossier de presse

    Energy Technology Data Exchange (ETDEWEB)

    Bourdier, Jean-Pierre [Electricite de France (EDF), 75 - Paris (France)

    1997-03-27

    In 1996 the actions of EDF in the domain of environment have recorded FF 4 billions (FF 3.5 billion in 1995), representing about 2% of the EDF's turnover. The EDF keeps on its efforts for reducing the impact of its activities upon environment. Several applications of an environment protective electricity generation are promoted by the company. The company brings services and technical solutions to its clients which meet their energy needs and conserving at the same time the life conditions. Furthermore, EDF participates in the activity of numerous national and international organisms, intervening in the environmental questions, in decision making, participating in studies and actions and following continually the direction of a durable economic and social development. The report is structured in three chapters: 1. an industrial responsibility; 2. services and techniques for environment; 3. action towards a durable development.

  8. Coordinated Charging of Electric Vehicles for Congestion Prevention in the Distribution Grid

    DEFF Research Database (Denmark)

    Hu, Junjie; You, Shi; Lind, Morten

    2014-01-01

    Distributed energy resources (DERs), like electric vehicles (EVs), can offer valuable services to power systems, such as enabling renewable energy to the electricity producer and providing ancillary services to the system operator. However, these new DERs may challenge the distribution grid due...... to insufficient capacity in peak hours. This paper aims to coordinate the valuable services and operation constraints of three actors: the EV owner, the Fleet operator (FO) and the Distribution system operator (DSO), considering the individual EV owner’s driving requirement, the charging cost of EV and thermal...... for their vehicles with lower cost. The congestion problem will be solved by a coordination between DSO and FOs through a distribution grid capacity market scheme. Then, a mathematical formulation of the market scheme is presented. Further, some case studies are shown to illustrate the effectiveness of the proposed...

  9. Redesign Electricity Market for the Next Generation Power System of Renewable Energy and Distributed Storage Technologies

    DEFF Research Database (Denmark)

    Feng, Donghan; Xu, Zhao; Østergaard, Jacob

    2010-01-01

    This paper proposes a stochastic time-series based method to simulate the volatility of intermittent renewable generation and distributed storage devices along timeline. The proposed method can calculate the optimal timeline for different electricity markets and power systems. In practice......, the proposed method is potentially useful for designing market rules and evaluating different design options. Following works is underway on application and simulation of proposed method using the realistic distribution system of Bornholm Island in Denmark....

  10. Development of an Emergency Restoration Process Simulator of Electric Power Distribution Equipments after a Disaster

    Science.gov (United States)

    Sagai, Shigeo; Shumuta, Yoshiharu

    We are developing a tool which can simulate the emergency restoration process of electric power distribution facilities in order to examine the methods to speed-up the process. This report is aiming following two objectives; 1)describing an overview of the tool “restoration simulator” that simulates the emergency restoration process of the distribution facilities after a disaster, 2)evaluating effectiveness of various restoration methods to speed-up the restoration process using the tool.

  11. Does Weather Have an Impact on Electricity Distribution Efficiency? Evidence from South America

    OpenAIRE

    Anaya, K. L.; Pollitt, M.G.

    2014-01-01

    This paper analyses the influence of weather variables on the efficiency of electricity distribution utilities in Argentina, Brazil, Chile and Peru. The data covers 82 firms that operate in the previously mentioned countries which represent more than 90 per cent of the distribution market of energy delivered for the period 1998-2008. The stochastic frontier analysis (SFA) is applied with a translog input distance function approach. A combination of cost and cost-quality models is proposed to ...

  12. Comparison of High-Fidelity Computational Tools for Wing Design of a Distributed Electric Propulsion Aircraft

    Science.gov (United States)

    Deere, Karen A.; Viken, Sally A.; Carter, Melissa B.; Viken, Jeffrey K.; Derlaga, Joseph M.; Stoll, Alex M.

    2017-01-01

    A variety of tools, from fundamental to high order, have been used to better understand applications of distributed electric propulsion to aid the wing and propulsion system design of the Leading Edge Asynchronous Propulsion Technology (LEAPTech) project and the X-57 Maxwell airplane. Three high-fidelity, Navier-Stokes computational fluid dynamics codes used during the project with results presented here are FUN3D, STAR-CCM+, and OVERFLOW. These codes employ various turbulence models to predict fully turbulent and transitional flow. Results from these codes are compared for two distributed electric propulsion configurations: the wing tested at NASA Armstrong on the Hybrid-Electric Integrated Systems Testbed truck, and the wing designed for the X-57 Maxwell airplane. Results from these computational tools for the high-lift wing tested on the Hybrid-Electric Integrated Systems Testbed truck and the X-57 high-lift wing presented compare reasonably well. The goal of the X-57 wing and distributed electric propulsion system design achieving or exceeding the required ?? (sub L) = 3.95 for stall speed was confirmed with all of the computational codes.

  13. Multi-Objective Scheduling of Electric Vehicles in Smart Distribution Network

    Directory of Open Access Journals (Sweden)

    Changhong Deng

    2016-11-01

    Full Text Available Due to the energy savings and environmental protection they provide, plug-in electric vehicles (PEVs are increasing in number quickly. Rapid development of PEVs brings new opportunities and challenges to the electricity distribution network’s dispatching. A high number of uncoordinated charging PEVs has significant negative impacts on the secure and economic operation of a distribution network. In this paper, a bi-level programming approach that coordinates PEVs’ charging with the network load and electricity price of the open market is presented. The major objective of the upper level model is to minimize the total network costs and the deviation of electric vehicle aggregators’ charging power and the equivalent power. The subsequent objective of the lower level model after the upper level decision is to minimize the dispatching deviation of the sum of PEVs’ charging power and their optimization charging power under the upper level model. An improved particle swarm optimization algorithm is used to solve the bi-level programming. Numerical studies using a modified IEEE 69-bus distribution test system including six electric vehicle aggregators verify the efficiency of the proposed model.

  14. Preventing Distribution Grid Congestion by Integrating Indirect Control in a Hierarchical Electric Vehicles Management System

    DEFF Research Database (Denmark)

    Hu, Junjie; Si, Chengyong; Lind, Morten

    2016-01-01

    In this paper, a hierarchical management system is proposed to integrate electric vehicles (EVs) into a distribution grid. Three types of actors are included in the system: Distribution system operators (DSOs), Fleet operators (FOs) and EV owners. In contrast to a typical hierarchical control...... system where the upper level controller directly controls the lower level subordinated nodes, this study aims to integrate two common indirect control methods:market-based control and price-based control into the hierarchical electric vehicles management system. Specifically, on the lower level...... of the hierarchy, the FOs coordinate the charging behaviors of their EV users using a price-based control method. A parametric utility model is used on the lower level to characterize price elasticity of electric vehicles and thus used by the FO to coordinate the individual EV charging. On the upper level...

  15. Impact and Cost Evaluation of Electric Vehicle Integration on Medium Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cheng, Lin; Pineau, Ulysse

    2013-01-01

    This paper presents the analysis of the impact of electric vehicle (EV) integration on medium voltage (MV) distribution networks and the cost evaluation of replacing the overloaded grid components. A number of EV charging scenarios have been studied. A 10 kV grid from the Bornholm Island...

  16. Improving Photovoltaic and Electric Vehicle Penetration in Distribution Grids with Smart Transformer

    DEFF Research Database (Denmark)

    Huang, Shaojun; Pillai, Jayakrishnan Radhakrishna; Liserre, Marco

    2013-01-01

    High penetration of electrical vehicles (EVs) and photovoltaics (PVs) can cause significant voltage issues in low voltage distribution grids. To certain extent, the transformer with on-load tap changers can regulate its output voltage, thus relieving the voltage issues and improve the hosting...

  17. Modeling the UT effect in global distribution of ionospheric electric fields

    DEFF Research Database (Denmark)

    Lukianova, R.; Christiansen, Freddy

    2008-01-01

    A new approach for modeling the global distribution of ionospheric electric potentials utilizing high-precision maps of field-aligned currents (FACs) derived from measurements by the Orsted and Magsat satellites as input to a comprehensive numerical scheme is presented. We simulate the universal ...

  18. Optimal Expansion Co-Planning of Reconfigurable Electricity and Natural Gas Distribution Systems Incorporating Energy Hubs

    Directory of Open Access Journals (Sweden)

    Xianzheng Zhou

    2017-01-01

    Full Text Available In a carbon-constrained world, natural gas with low emission intensity plays an important role in the energy consumption area. Energy consumers and distribution networks are linked via energy hubs. Meanwhile, reconfiguration that optimizes operational performance while maintaining a radial network topology is a worldwide technique in the electricity distribution system. To improve the overall efficiency of energy infrastructure, the expansion of electricity distribution lines and elements within energy hubs should be co-planned. In this paper, the co-planning process is modeled as a mixed integer quadratic programming problem to handle conflicting objectives simultaneously. We propose a novel model to identify the optimal co-expansion plan in terms of total cost. Operational factors including energy storages and reconfiguration are considered within the systems to serve electricity, cooling and heating loads. Reconfiguration and elements in energy hubs can avoid or defer new elements’ installation to minimize the investment cost, maintenance cost, operation cost, and interruption cost in the planning horizon. The proposed co-planning approach is verified on 3 and 12-node electricity and natural gas distribution systems coupled via energy hubs. Numerical results show the ability of our proposed expansion co-planning approach based on energy hub in meeting energy demand.

  19. Electrical resistivity sounding to study water content distribution in heterogeneous soils

    Science.gov (United States)

    Electrical resistivity (ER) sounding is increasingly being used as non-invasive technique to reveal and map soil heterogeneity. The objective of this work was to assess ER sounding applicability to study soil water distribution in spatially heterogeneous soils. The 30x30-m study plot was located at ...

  20. Electrical Market Management Considering Power System Constraints in Smart Distribution Grids

    Directory of Open Access Journals (Sweden)

    Poria Hasanpor Divshali

    2016-05-01

    Full Text Available Rising demand, climate change, growing fuel costs, outdated power system infrastructures, and new power generation technologies have made renewable distribution generators very attractive in recent years. Because of the increasing penetration level of renewable energy sources in addition to the growth of new electrical demand sectors, such as electrical vehicles, the power system may face serious problems and challenges in the near future. A revolutionary new power grid system, called smart grid, has been developed as a solution to these problems. The smart grid, equipped with modern communication and computation infrastructures, can coordinate different parts of the power system to enhance energy efficiency, reliability, and quality, while decreasing the energy cost. Since conventional distribution networks lack smart infrastructures, much research has been recently done in the distribution part of the smart grid, called smart distribution grid (SDG. This paper surveys contemporary literature in SDG from the perspective of the electricity market in addition to power system considerations. For this purpose, this paper reviews current demand side management methods, supply side management methods, and electrical vehicle charging and discharging techniques in SDG and also discusses their drawbacks. We also present future research directions to tackle new and existing challenges in the SDG.

  1. ELECTRIC FIELD MEASUREMENT IN ROD-DISCONTINUED PLANE AIR GAPS USING DISTRIBUTED CAPACITY PROBE

    Directory of Open Access Journals (Sweden)

    A. Khechekhouche

    2015-07-01

    Full Text Available The present experimental carried out investigations aimed at elucidating the effect of earth discontinuity on the breakdown voltage of short rod-plane air gap (80 to160 mm under negative lightning impulses (-1.2/50ms.We also carried out investigations on electric field measurement on the surface of a discontinuous plane of a rod-plane air gap arrangement. For this purpose, we used a probe with distributed capacity, under negative lightning applied impulse voltage. The probe is incorporated on the same level of plane surface.The interface locally reinforces the electric field. The electric field increases at the interface may lead to a discharge between the high voltage rode and the interface. In the vicinity of the interface, we observe a kind of discontinuity in the evolution of the electric field intensity. This one becomes greater than the value obtained in the case of gaps with homogeneous plane earth.

  2. ELECTRIC FIELD MEASUREMENT IN ROD-DISCONTINUED PLANE AIR GAPS USING DISTRIBUTED CAPACITY PROBE

    Directory of Open Access Journals (Sweden)

    A. Khechekhouche

    2014-06-01

    Full Text Available The present experimental carried out investigations aimed at elucidating the effect of earth discontinuity on the breakdown voltage of short rod-plane air gap (80 to 160 mm under negative lightning impulses (-1.2/50s. We also carried out investigations on electric field measurement on the surface of a discontinuous plane of a rod-plane air gap arrangement. For this purpose, we used a probe with distributed capacity, under negative lightning applied impulse voltage. The probe is incorporated on the same level of plane surface. The interface locally reinforces the electric field. The electric field increases at the interface may lead to a discharge between the high voltage rode and the interface. In the vicinity of the interface, we observe a kind of discontinuity in the evolution of the electric field intensity. This one becomes greater than the value obtained in the case of gaps with homogeneous plane earth.

  3. Electric field distribution and current emission in a miniaturized geometrical diode

    Science.gov (United States)

    Lin, Jinpu; Wong, Patrick Y.; Yang, Penglu; Lau, Y. Y.; Tang, W.; Zhang, Peng

    2017-06-01

    We study the electric field distribution and current emission in a miniaturized geometrical diode. Using Schwarz-Christoffel transformation, we calculate exactly the electric field inside a finite vacuum cathode-anode (A-K) gap with a single trapezoid protrusion on one of the electrode surfaces. It is found that there is a strong field enhancement on both electrodes near the protrusion, when the ratio of the A-K gap distance to the protrusion height d /h COMSOL simulations. We calculate the effective field enhancement factor for the field emission current, by integrating the local Fowler-Nordheim current density along the electrode surfaces. We systematically examine the electric field enhancement and the current rectification of the miniaturized geometrical diode for various geometric dimensions and applied electric fields.

  4. Predicting the electric field distribution in the brain for the treatment of glioblastoma.

    Science.gov (United States)

    Miranda, Pedro C; Mekonnen, Abeye; Salvador, Ricardo; Basser, Peter J

    2014-08-07

    The use of alternating electric fields has been recently proposed for the treatment of recurrent glioblastoma. In order to predict the electric field distribution in the brain during the application of such tumor treating fields (TTF), we constructed a realistic head model from MRI data and placed transducer arrays on the scalp to mimic an FDA-approved medical device. Values for the tissue dielectric properties were taken from the literature; values for the device parameters were obtained from the manufacturer. The finite element method was used to calculate the electric field distribution in the brain. We also included a 'virtual lesion' in the model to simulate the presence of an idealized tumor. The calculated electric field in the brain varied mostly between 0.5 and 2.0 V cm( - 1) and exceeded 1.0 V cm( - 1) in 60% of the total brain volume. Regions of local field enhancement occurred near interfaces between tissues with different conductivities wherever the electric field was perpendicular to those interfaces. These increases were strongest near the ventricles but were also present outside the tumor's necrotic core and in some parts of the gray matter-white matter interface. The electric field values predicted in this model brain are in reasonably good agreement with those that have been shown to reduce cancer cell proliferation in vitro. The electric field distribution is highly non-uniform and depends on tissue geometry and dielectric properties. This could explain some of the variability in treatment outcomes. The proposed modeling framework could be used to better understand the physical basis of TTF efficacy through retrospective analysis and to improve TTF treatment planning.

  5. The Canadian Niagara Power Company story

    Energy Technology Data Exchange (ETDEWEB)

    Ball, N.R. [Waterloo Univ., ON (Canada). Dept. of Electrical and Computer Engineering

    2005-07-01

    This book chronicles the history and contributions of the Canadian Niagara Power Company and its employees toward the establishment of electricity generation and distribution in Niagara Falls and Fort Erie, Ontario, dating back to its founding in 1892. Through historical photographs, maps and drawings, the book demonstrates the impact of electricity on the Niagara region. It emphasizes the many skills and jobs required to run the company that generated electricity and maintained a complete system to deliver power, metering, and billing services through the depression, wars, and postwar booms, even during lightning, snow and ice storms. The company began producing power in 1905 with what had been the world's largest-capacity turbines and generators that supplied power to both sides of the Niagara River. Initially, most of the electricity was exported to New York State. The company eventually expanded its Canadian customer service area from Niagara Falls, Ontario, to Fort Erie, Bridgeburg, Amigari, Ridgeway, Stevensville, Crystal Beach and Point Abino. Throughout its history, the Canadian Niagara Power Company provided power at a lower cost than its neighbouring competitors. The William Birch Rankine Generating Station became an important tourist attraction, showcasing the latest electrical appliances of the time in an effort to promote the use of electricity in homes and offices. Today, the station remains a tribute to the fact that natural beauty can coincide with industry. The book also chronicles the difficult business challenges caused by restructuring in the electric power industry in the 1990s, repairing aging equipment and applying the latest in automation and remote sensing technology. Today, the company as FortisOntario is expanding to other communities around Ontario. refs., tabs., figs.

  6. 75 FR 4427 - Pacific Gas & Electric Company; Notice of Intent To Prepare an Environmental Impact Statement and...

    Science.gov (United States)

    2010-01-27

    ... Company (PG&E) has submitted an application for renewal of facility Operating License Nos. DPR-80 and DPR... docketing of the applications and opportunity for hearing regarding renewal of the facility operating.... Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in...

  7. Auditor´s report of report of companies of the brazilian electrical sector: one study of the normative adherence of the reports emited between 1999 and 2006

    Directory of Open Access Journals (Sweden)

    Marcelo Haendchen Dutra

    2008-07-01

    Full Text Available The purpose of the present study was to verify the adherence to the normative demands found in the auditors’ reports concerned with the companies of the Brazilian electrical sector. To reach the proposed goal, an exploratory-descriptive study of report samples published between 1999 and 2006 was undertaken, covering the financial statements issued from 1998 to 2005, selected from Closing Balance, of Gazeta Mercantil. The research has an descriptive character and used the content analysis technique for the data analysis and interpretation. The approach adopted was both qualitative and quantitative. 136 auditors’ reports were scrutinized through the comparison between paragraphs contained in those reports and the aforementioned auditing standards issued by the regulating organ, the Accounting Federal Board. 936 frequencies were acknowledged, being divided into adherent and non-adherent, and the 14,9% of non-adherent ones were minutely discussed. Key words: Auditors’ Report, Auditing Standards and Electrical Sector.

  8. Wireless system for location of permanent faults by short circuit current monitoring in electric power distribution network; Sistema wireless para localizacao de faltas permanentes atraves da monitoracao da corrente de curto-circuito em redes de distribuicao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Machado, A.G.; Correa, A.C.; Machado, R.N. das M.; Ferreira, A.M.D.; Pinto, J.A.C. [Instituto Federal de Educacao, Ciencia e Tecnologia do Para (IFPA), Belem, PA (Brazil)], E-mail: alcidesmachado000@yahoo.com.br; Barra Junior, W. [Universidade Federal do Para (UFPA), Belem, PA (Brazil). Inst. de Tecnologia. Faculdade de Engenharia Eletrica], E-mail: walbarra@ufpa.br

    2009-07-01

    This paper presents the development of an automatic system for permanent short-circuits location in medium voltage (13.8 kV) electric power system distribution feeders, by indirect monitoring of the line current. When a permanent failure occurs, the developed system uses mobile telephony (GSM) text messages (SMS) to inform the power company operation center where the failure most likely took place. With this information in real time, the power company operation center may provide the network restoration in a faster and efficient way. (author)

  9. Distributed Control and Management of Renewable Electric Energy Resources for Future Grid Requirements

    DEFF Research Database (Denmark)

    Mokhtari, Ghassem; Anvari-Moghaddam, Amjad; Nourbakhsh, Ghavameddin

    2016-01-01

    It is anticipated that both medium- and low-voltage distribution networks will include high level of distributed renewable energy resources, in the future. The high penetration of these resources inevitably can introduce various power quality issues, including; overvoltage and overloading...... strategy is a promising approach to manage and utilise the resources in future distribution networks to effectively deal with grid electric quality issues and requirements. Jointly, utility and customers the owners of the resources in the network are considered as part of a practical coordination strategy...

  10. Robust Multi-Objective PQ Scheduling for Electric Vehicles in Flexible Unbalanced Distribution Grids

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Soroudi, Alireza; Marinelli, Mattia

    2017-01-01

    . The robust formulation effectively considers the errors in the electricity price forecast and its influence on the EV schedule. Moreover, the impact of EV reactive power support on objective values and technical parameters is analysed both when EVs are the only flexible resources and when linked with other......With increased penetration of distributed energy resources and electric vehicles (EVs), different EV management strategies can be used for mitigating adverse effects and supporting the distribution grid. This paper proposes a robust multi-objective methodology for determining the optimal day...... demand response programs. The method is tested on a real Danish unbalanced distribution grid with 35% EV penetration to demonstrate the effectiveness of the proposed approach. It is shown that the proposed formulation guarantees an optimal EV cost as long as the price uncertainties are lower than...

  11. Distributed Cooperative Control of Multi Flywheel Energy Storage System for Electrical Vehicle Fast Charging Stations

    DEFF Research Database (Denmark)

    Sun, Bo; Dragicevic, Tomislav; Quintero, Juan Carlos Vasquez

    2015-01-01

    Plug-in electrical vehicles will play a critical role in future smart grid and sudden connection of electrical vehicles chargers may cause huge power-peaks with high slew-rates on grid. In order to cope with this issue, this paper applies a distributed cooperative control for fast charging station...... with dedicated paralleled flywheel-based energy storage system. The distributed DC-bus signaling method is employed in the power coordination of grid and flywheel converters, and a distributed secondary controller generates DC voltage correction term to adjust the local voltage set-point through a dynamic...... consensus based voltage observer by communicating with its neighbors. The control system can realize the power balancing and DC voltage regulation with low reliance on communications. Finally, real-time hardware-in-the-loop results have been reported in order to verify the feasibility of proposed approach....

  12. DEFINITION OF EFFICIENT REFERENCES FOR REGULATORY BENCHMARKING OF DISTRIBUTION COMPANIES DEFINICIÓN DE UNA REFERENCIA DE EFICIENCIA PARA LA REGULACIÓN POR COMPARACIÓN DE EMPRESAS DE DISTRIBUCIÓN

    Directory of Open Access Journals (Sweden)

    Raúl Sanhueza H

    2008-09-01

    Full Text Available The data envelopment analysis and the p-median methodology are formulated as tools to determine efficient references for regulatory benchmarking of electrical distribution companies. Distribution typical areas are determined for the purpose of establishing distribution tariffs in a process whose regulatory core is based on the efficient company concept. Its application within the framework of the last Chilean regulatory process is illustrated.Se formula un procedimiento basados en el análisis envolvente de datos y la metodología p-mediana para determinar una empresa de referencia eficiente para el proceso de regulación de las empresas de distribución eléctricas. Se determinan las áreas de distribución típicas para establecer las tarifas de distribución en un proceso cuyo núcleo regulador está basado en el concepto de empresa eficiente. Se aplica dentro del marco del último proceso regulador chileno.

  13. Co-combustion of refuse derived fuel and coal in a cyclone furnace at the Baltimore Gas and Electric Company, C. P. Crane Station

    Energy Technology Data Exchange (ETDEWEB)

    1982-03-01

    A co-combustion demonstration burn of coal and fluff refuse-derived fuel (RDF) was conducted by Teledyne National and Baltimore Gas and Electric Company. This utility has two B and W cyclone furnaces capable of generating 400 MW. The facility is under a prohibition order to convert from No. 6 oil to coal; as a result, it was desirable to demonstrate that RDF, which has a low sulfur content, can be burned in combination with coals containing up to 2% sulfur, thus reducing overall sulfur emissions without deleterious effects. Each furnace consists of four cyclones capable of generating 1,360,000 pounds per hour steam. The tertiary air inlet of one of the cyclones was modified with an adapter to permit fluff RDF to be pneumatically blown into the cyclone. At the same time, coal was fed into the cyclone furnace through the normal coal feeding duct, where it entered the burning chamber tangentially and mixed with the RDF during the burning process. Secondary shredded fluff RDF was prepared by the Baltimore County Resource Recovery Facility. The RDF was discharged into a receiving station consisting of a belt conveyor discharging into a lump breaker, which in turn, fed the RDF into a pneumatic line through an air-lock feeder. A total of 2316 tons were burned at an average rate of 5.6 tons per hour. The average heat replacement by RDF for the cyclone was 25%, based on Btu input for a period of forty days. The range of RDF burned was from 3 to 10 tons per hour, or 7 to 63% heat replacement. The average analysis of the RDF (39 samples) for moisture, ash, heat (HHV) and sulfur content were 18.9%, 13.4%, 6296 Btu/lb and 0.26% respectively. RDF used in the test was secondary shredded through 1-1/2 inch grates producing the particle size distribution of from 2 inches to .187 inches. Findings to date after inspection of the boiler and superheater indicate satisfactory results with no deleterious effects from the RDF.

  14. Integrating Multi-Domain Distributed Energy Systems with Electric Vehicle PQ Flexibility: Optimal Design and Operation Scheduling for Sustainable Low-Voltage Distribution Grids

    DEFF Research Database (Denmark)

    Morvaj, Boran; Knezovic, Katarina; Evins, Ralph

    2016-01-01

    Electricity and transport sectors have to be decarbonised in order to mitigate climate change effects leading to increased penetration of distributed energy systems (DES) and electric vehicles (EV) which can threaten the security of distribution grid operation. Proper design and operation...... in the stable operation. The model was applied to a real low-voltage Danish distribution grid where measurement data is available on hourly basis in order to determine EV flexibility impacts on carbon emissions, as well as the benefits of optimal DES design. The influence of EV reactive power control...... for minimising carbon emission in low-voltage distribution grids with high share of distributed energy resources and electric vehicles. The framework determines optimal EV flexibility usage (both active and reactive) while satisfying electric and thermal building demands, and maintaining the distribution grid...

  15. Evaluation of electric field distribution in electromagnetic stimulation of human femoral head.

    Science.gov (United States)

    Su, Yukun; Souffrant, Robert; Kluess, Daniel; Ellenrieder, Martin; Mittelmeier, Wolfram; van Rienen, Ursula; Bader, Rainer

    2014-12-01

    Electromagnetic stimulation is a common therapy used to support bone healing in the case of avascular necrosis of the femoral head. In the present study, we investigated a bipolar induction screw system with an integrated coil. The aim was to analyse the influence of the screw parameters on the electric field distribution in the human femoral head. In addition, three kinds of design parameters (the shape of the screw tip, position of the screw in the femoral head, and size of the screw insulation) were varied. The electric field distribution in the bone was calculated using the finite element software Comsol Multiphysics. Moreover, a validation experiment was set up for an identical bone specimen with an implanted screw. The electric potential of points inside and on the surface of the bone were measured and compared to numerical data. The electric field distribution within the bone was clearly changed by the different implant parameters. Repositioning the screw by a maximum of 10 mm and changing the insulation length by a maximum of 4 mm resulted in electric field volume changes of 16% and 7%, respectively. By comparing the results of numerical simulation with the data of the validation experiment, on average, the electric potential difference of 19% and 24% occurred when the measuring points were at a depth of approximately 5 mm within the femoral bone and directly on the surface of the femoral bone, respectively. The results of the numerical simulations underline that the electro-stimulation treatment of bone in clinical applications can be influenced by the implant parameters. © 2014 Wiley Periodicals, Inc.

  16. 78 FR 45989 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-07-30

    ... Power Corporation, Municipal Electric Authority of Georgia, and the City of Dalton, Georgia (the... finds that: A. The exemption is authorized by law; B. the exemption presents no undue risk to public...

  17. 78 FR 45987 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-07-30

    ... Power Corporation, Municipal Electric Authority of Georgia, and the City of Dalton, Georgia (the... Commission finds that: A. The exemption is authorized by law; B. the exemption presents no undue risk to...

  18. Controlling in power supply companies that use structured electricity procurement; Controlling in EVU bei einer strukturierten Beschaffung von Strom

    Energy Technology Data Exchange (ETDEWEB)

    Dutz, Andreas [prevero AG, Muenchen (Germany); Bernklau, Nadine [TU Muenchen (Germany). Lehrstuhl fuer Wirtschaftsethik

    2011-01-15

    The liberalisation of the electricity market continues to offer innovative avenues for trading, especially in procurement. This leads to higher levels of complexity and responsibility in the tasks of a power supplier's purchasing department. What is needed ultimately is a well-developed procurement controlling system. A recent study shows how such a system should be designed in the case of electricity.

  19. An application of multiple criteria decision-making techniques for ranking different national Iranian oil refining and distribution companies

    Directory of Open Access Journals (Sweden)

    Ibrahim Nazari

    2012-10-01

    Full Text Available Performance measurement plays an essential role on management of governmental agencies especially when profitability is not the primary concern and we need to consider other important factors than profitability such as customer satisfaction, etc. In this paper, we propose a multi-criteria decision making method to rank different national Iranian oil refining and distribution companies. The proposed study of this paper uses six factors including per capita supply, energy cost, physical productivity of labor, staff participation, quality control inspection of stations and education per capita. The proposed study uses Entropy to find the relative importance of each criterion and TOPSIS to rank 37 alternatives based on cities and three regions. The results of the implementation of our method indicate that central regions close to capital city of the country maintains the highest ranking (0.9122 while southern regions maintains the lowest comes in the lowest priority (0.0569 and the northern region is in the middle (0.7635.

  20. Integrated Computing, Communication, and Distributed Control of Deregulated Electric Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Bajura, Richard; Feliachi, Ali

    2008-09-24

    Restructuring of the electricity market has affected all aspects of the power industry from generation to transmission, distribution, and consumption. Transmission circuits, in particular, are stressed often exceeding their stability limits because of the difficulty in building new transmission lines due to environmental concerns and financial risk. Deregulation has resulted in the need for tighter control strategies to maintain reliability even in the event of considerable structural changes, such as loss of a large generating unit or a transmission line, and changes in loading conditions due to the continuously varying power consumption. Our research efforts under the DOE EPSCoR Grant focused on Integrated Computing, Communication and Distributed Control of Deregulated Electric Power Systems. This research is applicable to operating and controlling modern electric energy systems. The controls developed by APERC provide for a more efficient, economical, reliable, and secure operation of these systems. Under this program, we developed distributed control algorithms suitable for large-scale geographically dispersed power systems and also economic tools to evaluate their effectiveness and impact on power markets. Progress was made in the development of distributed intelligent control agents for reliable and automated operation of integrated electric power systems. The methodologies employed combine information technology, control and communication, agent technology, and power systems engineering in the development of intelligent control agents for reliable and automated operation of integrated electric power systems. In the event of scheduled load changes or unforeseen disturbances, the power system is expected to minimize the effects and costs of disturbances and to maintain critical infrastructure operational.

  1. Analysis of the electric field distribution in the diseased ovaries of cows

    Directory of Open Access Journals (Sweden)

    Вадим Сергеевич Попрядухин

    2017-01-01

    Full Text Available  This article is focused on solving the problem of the electromagnetic radiation distribution inside the ovaries of cattle. As a result of theoretical studies integral equation was obtained based on vector fields and integral formulas of vector field theory. Solving of the equation allowed to obtain formulas for the calculation of the electric field mean value inside of diseased ovaries. Mean value of the electric field is necessary for calculation of biotropic parameters for treatment of inflammation of ovaries

  2. Multi-agents Based Modelling for Distribution Network Operation with Electric Vehicle Integration

    DEFF Research Database (Denmark)

    Hu, Junjie; Morais, Hugo; Zong, Yi

    2014-01-01

    Electric vehicles (EV) can become integral part of a smart grid because instead of just consuming power they are capable of providing valuable services to power systems. To integrate EVs smoothly into the power systems, a multi-agents system (MAS) with hierarchical organization structure...... is proposed in this paper. The proposed MAS system consists of three types of agents: distribution system operator agent (DSO agent), electric vehicle fleet operator agent (EV FO agent or alternatively called virtual power plant agent) and EV agent. A DSO agent belongs to the top level of the hierarchy...

  3. Optimal planning of electric vehicle charging station at the distribution system using hybrid optimization algorithm

    DEFF Research Database (Denmark)

    Awasthi, Abhishek; Venkitusamy, Karthikeyan; Padmanaban, Sanjeevikumar

    2017-01-01

    India's ever increasing population has made it necessary to develop alternative modes of transportation with electric vehicles being the most preferred option. The major obstacle is the deteriorating impact on the utility distribution system brought about by improper setup of these charging...... stations. This paper deals with the optimal planning (siting and sizing) of charging station infrastructure in the city of Allahabad, India. This city is one of the upcoming smart cities, where electric vehicle transportation pilot project is going on under Government of India initiative. In this context...

  4. Electric Industry Structure and Regulatory Responses in a High Distributed Energy Resources Future

    Energy Technology Data Exchange (ETDEWEB)

    Corneli, Steve [Seventhwave, Madison, WI (United States); Kihm, Steve [Seventhwave, Madison, WI (United States); Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-11-01

    The emergence of distributed energy resources (DERs) that can generate, manage and store energy on the customer side of the electric meter is widely recognized as a transformative force in the power sector. This report focuses on two key aspects of that transformation: structural changes in the electric industry and related changes in business organization and regulation that are likely to result from them. Both industry structure and regulation are inextricably linked. History shows that the regulation of the power sector has responded primarily to innovation in technologies and business models that created significant structural changes in the sector’s cost and organizational structure.

  5. Optimal Strategy of Efficiency Power Plant with Battery Electric Vehicle in Distribution Network

    Science.gov (United States)

    Ma, Tao; Su, Su; Li, Shunxin; Wang, Wei; Yang, Tiantian; Li, Mengjuan; Ota, Yutaka

    2017-05-01

    With the popularity of electric vehicles (EVs), such as plug-in electric vehicles (PHEVs) and battery electric vehicles (BEVs), an optimal strategy for the coordination of BEVs charging is proposed in this paper. The proposed approach incorporates the random behaviours and regular behaviours of BEV drivers in urban environment. These behaviours lead to the stochastic nature of the charging demand. The optimal strategy is used to guide the coordinated charging at different time to maximize the efficiency of virtual power plant (VPP). An innovative peer-to-peer system is used with BEVs to achieve the goals. The actual behaviours of vehicles in a campus is used to validate the proposed approach, and the simulation results show that the optimal strategy can not only maximize the utilization ratio of efficiency power plant, but also do not need additional energies from distribution grid.

  6. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid (AVC-TeDP)

    Science.gov (United States)

    Gemin, Paul; Kupiszewski, Tom; Radun, Arthur; Pan, Yan; Lai, Rixin; Zhang, Di; Wang, Ruxi; Wu, Xinhui; Jiang, Yan; Galioto, Steve; hide

    2015-01-01

    The purpose of this effort was to advance the selection, characterization, and modeling of a propulsion electric grid for a Turboelectric Distributed Propulsion (TeDP) system for transport aircraft. The TeDP aircraft would constitute a miniature electric grid with 50 MW or more of total power, two or more generators, redundant transmission lines, and multiple electric motors driving propulsion fans. The study proposed power system architectures, investigated electromechanical and solid state circuit breakers, estimated the impact of the system voltage on system mass, and recommended DC bus voltage range. The study assumed an all cryogenic power system. Detailed assumptions within the study include hybrid circuit breakers, a two cryogen system, and supercritical cyrogens. A dynamic model was developed to investigate control and parameter selection.

  7. Optimization of electric field distribution by free carrier injection in silicon detectors operated at low temperatures

    CERN Document Server

    Eremin, V V; Verbitskaya, E

    2002-01-01

    This study presents the results on the modeling of the electric field distribution, which is controlled by injection and trapping of non- equilibrium carriers, in Si detectors irradiated by high neutron fluences. Analytical calculation of the electric field distribution in detectors irradiated by neutron fluences of H-10**1**4 to 5-10**1**5 cm**-**2 has been performed, which shows possibility of full depletion voltage reduction at low operational temperatures with hole injection. All calculations are focused on the improvement of charge collection efficiency and prediction for detector behavior in LHC experiments. Comparison of the results of calculations to the experimental data published earlier shows a good qualitative agreement. 10 Refs.

  8. Non-uniform distribution of outer hair cell transmembrane potential induced by extracellular electric field.

    Science.gov (United States)

    Ramamoorthy, Sripriya; Wilson, Teresa M; Wu, Tao; Nuttall, Alfred L

    2013-12-17

    Intracochlear electric fields arising out of sound-induced receptor currents, silent currents, or electrical current injected into the cochlea induce transmembrane potential along the outer hair cell (OHC) but its distribution along the cells is unknown. In this study, we investigated the distribution of OHC transmembrane potential induced along the cell perimeter and its sensitivity to the direction of the extracellular electric field (EEF) on isolated OHCs at a low frequency using the fast voltage-sensitive dye ANNINE-6plus. We calibrated the potentiometric sensitivity of the dye by applying known voltage steps to cells by simultaneous whole-cell voltage clamp. The OHC transmembrane potential induced by the EEF is shown to be highly nonuniform along the cell perimeter and strongly dependent on the direction of the electrical field. Unlike in many other cells, the EEF induces a field-direction-dependent intracellular potential in the cylindrical OHC. We predict that without this induced intracellular potential, EEF would not generate somatic electromotility in OHCs. In conjunction with the known heterogeneity of OHC membrane microdomains, voltage-gated ion channels, charge, and capacitance, the EEF-induced nonuniform transmembrane potential measured in this study suggests that the EEF would impact the cochlear amplification and electropermeability of molecules across the cell. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  9. Assessing the Potential of Plug-in Electric Vehicles in Active Distribution Networks

    DEFF Research Database (Denmark)

    Kordheili, Reza Ahmadi; Pourmousavi, Seyyed Ali; Savaghebi, Mehdi

    2016-01-01

    A multi-objective optimization algorithm is proposed in this paper to increase the penetration level of renewable energy sources (RESs) in distribution networks by intelligent management of plug-in electric vehicle (PEV) storage. The proposed algorithm is defined to manage the reverse power flow ...... demonstrate the capability of the algorithm in increasing solar power penetration in the grid up to 50%, depending on the PEV penetration level and the freedom of the system operator in managing the available PEV storage....

  10. Day-ahead tariffs for the alleviation of distribution grid congestion from electric vehicles

    DEFF Research Database (Denmark)

    O'Connell, Niamh; Wu, Qiuwei; Østergaard, Jacob

    2012-01-01

    An economically efficient day-ahead tariff (DT) is proposed with the purpose of preventing the distribution grid congestion resulting from electric vehicle (EV) charging scheduled on a dayahead basis. The DT concept developed herein is derived from the locational marginal price (LMP), in particular...... the congestion cost component of the LMP. A step-wise congestion management structure has been developed whereby the distribution system operator (DSO) predicts congestion for the coming day and publishes DTs prior to the clearing of the day-ahead market. EV fleet operators (FOs) optimize their EV charging...

  11. Non-linear electric analogs of the current distribution in porous electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Euler, K.J. (Arbeitsgurppe Technische Physik der Gesamthochschule, Kassel, Germany); Seim, B.

    1978-01-01

    Porous battery electrodes can, with respect to their volumetric current distribution, be regarded as electrical networks: linear, time-independent networks again can be treated by analytical methods. In some practical cases, however, deviations have to be considered: non-linear overvoltage functions, changing conductivities. Current distribution in such non-linear and time-dependent systems can be evaluated either by numerical computer calculations, or by the application of corresponding electrical analogs. The latter way is fairly simple and is discussed here. The observed overvoltage functions can be generated by semiconducting diodes. Changing conductivities are generated by adjustable resistors. Application of special automatic devices, e.g. diaphragms with closing pores, seems possible but has not been effected so far. Voltage and current scales have to be adapted to the characteristics of the electronic components. In general, in some practical electrodes the real overvoltage functions may change the current distribution markedly. Particular shoulders in the distribution curves are observed, which ameliorate the electrode utilization. Introduction of measured ionic conductivity changes certainly influences the current distribution, but results in deteriorations of the predicted electrode characteristics. 8 figures, 4 tables.

  12. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

    Science.gov (United States)

    Armstrong, Michael J.; Blackwelder, Mark; Bollman, Andrew; Ross, Christine; Campbell, Angela; Jones, Catherine; Norman, Patrick

    2015-01-01

    The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

  13. NON-UNIFORMITY OF THE DISTRIBUTION OF ELECTRICAL TRANSMEMBRANE POTENTIALS IN CARDIAC DEFIBRILLATION

    Directory of Open Access Journals (Sweden)

    O. E. Gudkova

    2015-01-01

    Full Text Available The need for emergency cessation of ventricular fibrillation is one of the problems of modern reanimatology. In spite of searches for novel methods, there is the only effective method — electrical cardiac defibrillation.Objective: to investigate the effect of different forms of pulses on cell membranes in a model experiment and to assess their use for effective cardiac defibrillation.Materials and methods. The Maxwell model was used for theoretical analysis of the spatial distribution of an electric field in the red blood cell membrane. The electric effect on a single cell was calculated using the experimental findings and the equivalent electrical circuit of the myocardial structure during a defibrillation procedure. The cardiomyocyte membrane potential upon exposure to defibrillator discharge was estimated. Exposure of the red blood cell membrane to single, two unipolar and two heteropolar pulses was examined.Results. There is non-additivity of speeds upon double exposure as compared to single one. Single pulse causes a lower effect of electroporation than two double pulses. Hyperpolarization and depolarization processes in the cardiomyocyte membranes occur successively during electrical cardiac defibrillation.Conclusion. Two heteropolar pulses cause an effect of biological membrane electroporation with a greater probability than two unipolar ones.

  14. Distributed generation in European electricity markets. Current challenges and future opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Ropenus, S. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy. Systems Analysis Div., Roskilde (Denmark))

    2010-07-01

    This Ph.D. thesis studies the role of distributed generation in European electricity markets. It focuses primarily on the interactions of economics and policy with the aim of contributing to the understanding of how distributed generation is embedded in the present regulatory and market framework, which barriers exist, and which role it may possibly play in the future. To capture the interdisciplinarity of the topic, a combination of qualitative and quantitative methods is applied. Subsequent to the identification of barriers, this thesis turns to the microeconomic perspective on the interplay of vertical structure, regulation and distributed generation. This is done through the application of quantitative methods in the form of partial equilibrium models focusing on the effects induced by the vertical structure of the network operator, either a combined operator or a distribution system operator, in a market with small distributed producers. In areas where the promotion of renewable energy sources and combined heat and power has induced a substantial increase in distributed generation, new challenges in system integration arise. In particular, high levels of generation from intermittent energy sources, such as wind, add to the complexity of network operation and control, which can hardly be tackled with the present 'fit and forget' approach. The conclusion is that distributed generation has great potential to enhance competitiveness, sustainability and security of supply in European electricity markets. A prerequisite is the removal of market and regulatory barriers, taking the interdependencies of vertical structure, support mechanisms and network access into account. In the future, higher penetration levels of distributed generation necessitate changes in the power system and the adoption of new technologies, where hydrogen production by grid connected electrolysis constitutes one example. (LN)

  15. The integration of renewable energy sources into electric power distribution systems. Volume 2, Utility case assessments

    Energy Technology Data Exchange (ETDEWEB)

    Zaininger, H.W.; Ellis, P.R.; Schaefer, J.C. [Zaininger Engineering Co., San Jose, CA (United States)

    1994-06-01

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: (1) The local solar insolation and/or wind characteristics; (2) renewable energy source penetration level; (3) whether battery or other energy storage systems are applied; and (4) local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kw-scale applications may be connected to three-phase secondaries, and larger hundred-kW and MW-scale applications, such as MW-scale windfarms or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications.

  16. Integration of Electric Vehicles into the Power Distribution Network with a Modified Capacity Allocation Mechanism

    Directory of Open Access Journals (Sweden)

    Junjie Hu

    2017-02-01

    Full Text Available The growing penetration of electric vehicles (EVs represents an operational challenge to system operators, mainly at the distribution level by introducing congestion and voltage drop problems. To solve these potential problems, a two-level coordination approach is proposed in this study. An aggregation entity, i.e., an EV virtual power plant (EV-VPP, is used to facilitate the interaction between the distribution system operator (DSO and EV owners considering the decentralized electricity market structure. In level I, to prevent the line congestion and voltage drop problems, the EV-VPP internally respects the line and voltage constraints when making optimal charging schedules. In level II, to avoid power transformer congestion problems, this paper investigates three different coordination mechanisms, or power transformer capacity allocation mechanisms, between the DSO and the EV-VPPs, considering the case of EVs charging and discharging. The three mechanisms include: (1 a market-based approach; (2 a pro-rata approach; and (3 a newly-proposed constrained market-based approach. A case study considering a 37-bus distribution network and high penetration of electric vehicles is presented to demonstrate the effectiveness of the proposed coordination mechanism, comparing with the existing ones.

  17. New model of Brazilian electric sector: implications of sugarcane bagasse on the distributed generation process

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Celso E.L. de; Rabi, Jose A. [Universidade de Sao Paulo (GREEN/FZEA/USP), Pirassununga, SP (Brazil). Fac. de Zootecnia e Engenharia de Alimentos. Grupo de Pesquisa em Reciclagem, Eficiencia Energetica e Simulacao Numerica], Emails: celsooli@usp.br, jrabi@usp.br; Halmeman, Maria Cristina [Universidade Estadual Paulista (FCA/UNESP), Botucatu, SP (Brazil). Fac. de Ciencias Agronomicas

    2008-07-01

    Distributed generation has become an alternative for the lack of resources to large energy projects and for recent facts that have changed the geopolitical panorama. The later have increased oil prices so that unconventional sources have become more and more feasible, which is an issue usually discussed in Europe and in USA. Brazil has followed such world trend by restructuring the electrical sector as well as major related institutions, from generation to commercialization and sector regulation while local legislation has enabled the increase of distributed generation. It regulates the role of the independent energy producer so as to provide direct business between the later and a great consumer, which is an essential step to enlarge energy market. Sugarcane bagasse has been used to produce both electric energy and steam and this paper analyzes and discusses the major implications of a new model for Brazilian electric sector based on sugarcane bagasse use as means to increase distributed generation process, particularly concerned with the commercialization of energy excess. (author)

  18. Digest of "Utilization of Electric Vehicles Connected to Distribution Substations for Peak Shaving of Utility Network Loads"

    OpenAIRE

    Mägi, Marek

    2013-01-01

    Use of modern electric vehicles and their effective integration into power grids depends on the technologies applied around distribution substations. Distribution substations equipped with energy storing and V2G capability enable peak load shaving and demand response, which will reduce the need to make new investments into building new power sources or power grids to meet peak demand. This paper presents a distribution substation topology for utilizing electric vehicles as energy resource uni...

  19. Results of photovoltaic power generation system operation in Tokyo Electric Power Company; Tokyo Denryoku ni okeru taiyoko hatsuden setsubi no unten jisseki ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, H.; Itokawa, K. [Tokyo Electric Power Co. Inc., Tokyo (Japan)

    1996-10-27

    A report was made on the measurement of data and the results of the analysis at 14 sites of photovoltaic power generation facilities operated under system interconnection by Tokyo Electric Power Company. This type of system is provided in 40 sites as of the end of fiscal 1995, generating 479kw. The items measured were the generated electric energy at all 14 sites, and the quantity of solar radiation, outside air temperature, panel temperature, etc., at limited sites; and the capacity of each equipment, azimuth and inclination of the panel were also recorded simultaneously. Hourly values were used for the analysis. Five minute values were utilized, however, in the examination of the cause of lowered output and in the situation recognition of the influence of the shade or the change of weather. The utilization factor of the facilities was in the average 10.8% in fiscal 1994 and 10.7% in fiscal 1995. The factor decreased slightly unless the panel azimuth faced due south. The utilization factor at the panel inclination of 35 degrees and 45 degrees showed both 10.4% through the year making no difference. The system seemed to show no overwhelming possibilities in coping with electric power demand. The reason was that deviation existed for 2 hours or so in the peak and that reliability was low as basic power facilities. However, it was determined that the system be continuously examined in future. 9 figs., 1 tab.

  20. The Integration of Renewable Energy Sources into Electric Power Distribution Systems, Vol. II Utility Case Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Zaininger, H.W.

    1994-01-01

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: the local solar insolation and/or wind characteristics, renewable energy source penetration level, whether battery or other energy storage systems are applied, and local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kW-scale applications may be connected to three+phase secondaries, and larger hundred-kW and y-scale applications, such as MW-scale windfarms, or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. In any case, the installation of small, distributed renewable energy sources is expected to have a significant impact on local utility distribution primary and secondary system economics. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications. The

  1. The effects of deregulation on rural electric distribution cooperatives: An empirical analysis

    Science.gov (United States)

    Greer, Monica Lynne

    In 1996, the Federal Energy Regulatory Commission ("FERC") issued Orders 888 and 889, which were designed to promote competition in wholesale markets for electricity. While these Orders were predominantly meant to apply to vertically integrated investor-owned utilities ("IOUs"), FERC recently issued a Notice of Proposed Rulemaking that indicates its intent to make all transmission-owning entities, including those of cooperatively-owned utilities and the federal power administrations subject to FERC jurisdiction. Cooperatively owned utilities ("coops"), the focus of this paper, are organized as either generation and transmission ("G&T") or distribution only. And, although there are typically long-term contracts between the G&T and the distribution coops (thus rendering them quasi-vertically-integrated), they are very different from their investor-owned counterparts. It is because of these differences that the economic viability of these entities is being questioned in a deregulated environment. This dissertation examines the ability of coops to continue operating in their present form in a restructured electricity market. More specifically, using 1996 data for 831 distribution coops I estimate both quadratic and translogarithmic cost specifications so as to ascertain whether these firms are operating in such a fashion as to minimize costs. I find evidence that they are not. When delivered power is modeled as a single-output translogarithmic cost equation, I find that the majority of firms in the sample were operating in the increasing returns to scale portion of the average cost curve in 1996. This result reveals that coops delivered far less electricity to all customer classes than was necessary to attain the minimum efficient scale. And, upon estimating a multiple-output quadratic cost function, I find that there are ray economies, product specific returns to scale, and economies of scope in the distribution of electricity to the various customer classes that are

  2. TECHNOLOGY MANAGEMENT IN THE DEREGULATED ELECTRICITY DISTRIBUTION INDUSTRY: THE SOUTH AFRICAN CASE

    Directory of Open Access Journals (Sweden)

    M.G.B. Madonsela

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: The subject of deregulation of electricity utilities has, in the past two decades, dominated the discussions on global Electricity Supply Industries (ESIs. Deregulation may be viewed as the withdrawal of state regulatory powers from the generation, transmission and distribution of electrical power to facilitate liberalised power markets. The key drivers for deregulation in South Africa are global competitiveness; a quest for local industrial development through cost-effective services; equitable and sustainable power supplies and the social empowerment of communities through the eradication of poverty. The present Electricity Distribution Industry (EDI, which is a component of the ESI, is made up of Eskom Distribution and about 368 municipal distributors. At present, both these entities run their businesses according to differing “business” principles. With technology being one of the driving forces of economic growth, this article analyses the deregulated EDI and proposes a technology management model that can be adopted after deregulation.

    AFRIKAANSE OPSOMMING: Gedurende die afgelope twee dekades oorheers die deregulering van elektrisiteitsvoorsiening besprekings oor die globale voorsiening van elektrisiteit. Deregulering beteken die verwydering van staatsbeheer oor die opwekking, transmissie en verspreiding van elektrisiteit om sodoende geliberaliseerde drywingsmarkte te ondersteun. Die aansporing vir deregulering in Suid-Afrika gaan om globale mededingendheid, om ondersteuning vir die ontwikkeling van plaaslike industrieë deur koste-effektiewe dienslewering, en om die voorsiening van gangbare en volhoubare kragbronne vir die bemagtiging van gemeenskappe vir die bekamping van armoede. Tans bestaan die elektriesiteitsverspreidingsbedryf uit Eskom-verspreiding en ongeveer 368 munisipale verspreiders. Hierdie samestelling maak onderling gebruik van uiteenlopende sakebeginsels. Hierdie artikel hou 'n tegnologiese

  3. Power Sharing Control between Load-Side Inverters in DC Microgrid for Super High Quality Electric Power Distribution System

    Science.gov (United States)

    Kakigano, Hiroaki; Nada, Kaho; Miura, Yushi; Ise, Toshifumi; Uchida, Ryohei

    DC microgrid is a novel power system using dc distribution in order to provide a super high quality electric power. The dc distribution system is suitable for dc output type distributed generations such as photovoltaic and fuel cells, and energy storages such as batteries and electric double layer capacitors. Power is distributed through dc distribution line and converted to required ac or dc voltage by converters placed near loads. Load-side single phase inverters are connected through transformers in order to share active and reactive power. In this paper, a power sharing control scheme was proposed, and the power sharing characteristics were demonstrated by experimental results.

  4. Methods to Regulate Unbundled Transmission and Distribution Business on Electricity Markets

    Energy Technology Data Exchange (ETDEWEB)

    Forsberg, Kaj; Fritz, Peter

    2003-11-01

    The regulation of distribution utilities is evolving from the traditional approach based on a cost of service or rate of return remuneration, to ways of regulation more specifically focused on providing incentives for improving efficiency, known as performance-based regulation or ratemaking. Modern regulation systems are also, to a higher degree than previously, intended to simulate competitive market conditions. The Market Design 2003-conference gathered people from 18 countries to discuss 'Methods to regulate unbundled transmission and distribution business on electricity markets'. Speakers from nine different countries and backgrounds (academics, industry and regulatory) presented their experiences and most recent works on how to make the regulation of unbundled distribution business as accurate as possible. This paper does not claim to be a fully representative summary of everything that was presented or discussed during the conference. Rather, it is a purposely restricted document where we focus on a few central themes and experiences from different countries.

  5. Routing of Electric Vehicles: Case Study of City Distribution in Copenhagen

    DEFF Research Database (Denmark)

    Linde, Esben; Larsen, Allan; Nørrelund, Anders Vedsted

    freight magnitude and the distribution of goods in the old city centre. Based on the survey, analysis of possible UCC locations was carried out using simulation. Distribution from the UCC is assumed to be conducted with electric vehicles (EVs) as they are considered suitable for the overall aim. However...... a tour. Furthermore, intelligent location of these recharging points is considered. The objective is to find a least cost plan for routing and recharging the vehicles so that each customer is serviced by exactly one vehicle within its time windows and the vehicle capacity and driving range constraints...... are satisfied. The EVRPTW is a new problem that only has received little attention in the literature; see for example [2] and [3]. The costs are compared to distribution conducted by conventional vehicles. A heuristic method is developed and tested on the data generated on the basis of real-life collected data...

  6. Improving and Handling Electric Vehicle Penetration Level by Different Smart Charging Algorithms in Distribution Grids

    DEFF Research Database (Denmark)

    Kordheili, Reza Ahmadi; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2015-01-01

    This paper proposes different smart charging algorithms for electric vehicles (EVs) to find out the maximum grid capability in dealing with these new devices. The main objective is to obtain maximum EV penetration in the distribution grid without reinforcing the grid in order to avoid any cost...... for distribution system operators (DSOs). Two smart charging algorithms are proposed in this study. The proposed algorithms are applied to a part of the Danish distribution grid as a case study. As a comparison, a dumb charging scenario, i.e. charging EVs without any specific order or algorithm, is also simulated....... Simulation results demonstrate the capability of the smart charging methods to increase the penetration of EVs up to three times, compared to the base case....

  7. Particle Velocity Distributions and Large-Scale Electric Field in Solar Wind

    Science.gov (United States)

    Pavan, J.; Vinas, A. F.

    2016-12-01

    Velocity distributions of particles are key elements in the study of solar wind. The physical mechanisms that regulate their many features are a matter of debate. The present work addresses the subject with a fully analytical method in order to establish the shape of particle velocity distributions in solar wind. The method consists in solving the steady-state kinetic equation for particles and the related fluid equations, assigning spatial profiles for density and temperature matching observational data. The model is one-dimensional in configuration-space and two-dimensional in velocity-space, and accounts for large-scale processes, namely, advection, gravity, magnetic mirroring and the large-scale ambipolar electric field, without the aid of wave-particle interactions or collisions. The findings reported add to the general understanding of regulation of particle distributions in solar wind and to the predictions of their shape in regions restricted for in situ measurements.

  8. SEOP cross subsidization between electricity generation companies as a complementary concept to the tax on electricity?; SEOP-Quersubventionierung zwischen Stromproduzenten als Komplementaerkonzept zur Elektrizitaetssteuer?

    Energy Technology Data Exchange (ETDEWEB)

    Krumm, R.

    2000-07-01

    The electricity tax charged in Germany contributes to reducing carbon dioxide emissions in an indirect way, i.e. via the price policy, which is intended to reduce energy consumption. As the taxation approach does not differentiate between renewable or depletable primary energy sources, the tax does not create incentives for an ecologically favourable restructuring of the generation industry. The document in hand therefore explains a complementary approach which introduces the ecological dimension. It is recommended to add a fiscal approach called SEOP, Sectoral tax on Emissions with Output-determined Partial redistribution. Adopting this policy instrument would mean to implement a cross subsidization of low-emission or no-emission electricity generation technologies by the CO2-intensive generation technologies, as a demand-side or technology-based measure supporting the intentions of the tax. Introduction of the SEOP fiscal system is expected to achieve a significant abatement of carbon dioxide emissions due to electricity generation. (orig./CB) [German] Die in der Bundesrepublik erhobene Elektrizitaetssteuer leistet einen Klimaschutzbeitrag nur insoweit, als sie ueber die Induzierung von Preissteigerungen die Stromnachfrage mindert. Da die steuerliche Belastung fuer alle Primaerenergietraeger gleich hoch ist, setzt sie aber keinerlei Anreize fuer eine oekologische Umstrukturierung der Stromerzeugung. Vor diesem Hintergrund wird vorgeschlagen, die Elektrizitaetssteuer durch ein sogenanntes SEOP-Fiskalsystem zu ergaenzen, welches eine Quersubventionierung emissionsarmer und emissionsfreier Elektrizitaetsproduktion durch CO{sub 2}-intensive Stromherstellungsverfahren impliziert. Durch eine solche produktions- bzw. angebotsseitige 'Flankierung' der Elektrizitaetssteuer waere eine spuerbare Minderung der stromerzeugungsbedingten CO{sub 2}-Emissionen realisierbar. (orig.)

  9. Research on application model of blockchain technology in distributed electricity market

    Science.gov (United States)

    Cheng, S.; Zeng, B.; Huang, Y. Z.

    2017-11-01

    In the context of current energy Internet, the emergence of a large number of energy productive consumers will create a new business model. In the decentralized electricity market, the cost of traditional centralized solution construction, management and maintenance is too high, and it is difficult to support the collection, transmission, reception, storage and analysis of massive data. To provide a solution to this phenomenon, we apply the blockchain technology to this distributed electricity market to achieve peer to peer transactions in the power systems. The blockchain technology which is very popular nowadays will be used in power system to establish a credible direct transaction between devices. At first, this article analyzes the future direction of the development of power systems, studies the characteristics of decentralized power systems and summarizes the main issues in the development process. Then, we analyze the basic characteristics of blockchain and put forward a new transaction framework in consideration of problems existing in current energy market. The transaction framework is based on the blockchain technology in the distributed electricity market and includes the pricing method, the power transaction system architecture, various modules of the trading system and the details of the whole transaction system runtime. This framework provides a viable solution for increasingly complex energy transactions.

  10. Electrical Resistivity Monitoring for Leachate Distribution at Two Foot-and-Mouth- Disease (FMD) Burial Sites

    Science.gov (United States)

    Lee, S.; Kaown, D.; Lee, K.; Leem, K.; Ko, K.

    2011-12-01

    The main objective of this study was to provide the basic information on leachate distribution with time changes through the electrical resistivity monitoring for a certain period of time in the Foot-and-Mouth-Disease (FMD) burial facilities which is needed to prevent further soil and groundwater contamination and to build an effective plan for stabilization of the burial site. In this study, dipole-dipoles surveys were carried out around two FMD burial sites in Iceon-si, Gyeonggi-do. The FMD burial facility installed at Daewall-myeon is consists of one block but, at Yul-myeon, it is divided into 2 blocks named A and B blocks. Dipole-Dipole surveys with 8 lines at Yul-myeon and 3 lines at Daewall-myeon were carried out. The observed leachate distribution along survey lines was not clearly evident as time passes at Daewall-myeon site, but, at Yul-myeon site, the leachate distribution around the survey lines showed a decrease of resistivity around the burial facility. At and around A and B blocks of Yul-myeon site, interpretations of the survey data show low resistivity zones below 10 Ωm from a depth 3 m to 10 m and such low resistivity zones of the A block are thicker than the B block by about 5~10 m. From the geochemical data and resistivity survey at two FMD burial sites, it is inferred that the groundwater within a 50-meter radius around burial facilities of the Yul-myeon site are contaminated by leachate. The general resistivity distribution around the burial site is seemed affected by the leachate with high electrical conductivity. The detail distribution patterns can be explained by local distributions of soil and weathered rocks and associated leachate flow. This subject is supported by Brain Korea 21 and Korea Ministry of Environment as 'The GAIA Project (173-092-009)'.

  11. Control Strategy for Power Distribution in Dual Motor Propulsion System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Pedro Daniel Urbina Coronado

    2015-01-01

    Full Text Available Electric Vehicles with more than one electric motor can offer advantages in saving energy from the batteries. In order to do that, the control strategy plays an important role in distributing the required torque between the electric motors. A dual motor propulsion system with a differential transmission is simulated in this work. A rule based control strategy for this propulsion system is proposed and analyzed. Two parameters related to the output speed of the transmission and the required torque are used to switch the two modes of operation in which the propulsion system can work under acceleration. The effect of these parameters is presented over the driving cycles of NEDC, UDDS, and NYCC, which are followed using a PID controller. The produced energy losses are calculated as well as an indicator of drivability, which is related to the difference between the desired speed and the actual speed obtained. The results show that less energy losses are present when the vehicle is maintained with one electric motor most of the time, switching only when the extended speed granted by the second motor is required. The propulsion system with the proposed control strategy represents a feasible alternative in the spectrum of sustainable transportation architectures with extending range capabilities.

  12. Modeling and Simulation of Power Distribution System in More Electric Aircraft

    Directory of Open Access Journals (Sweden)

    Zhangang Yang

    2015-01-01

    Full Text Available The More Electric Aircraft concept is a fast-developing trend in modern aircraft industry. With this new concept, the performance of the aircraft can be further optimized and meanwhile the operating and maintenance cost will be decreased effectively. In order to optimize the power system integrity and have the ability to investigate the performance of the overall system in any possible situations, one accurate simulation model of the aircraft power system will be very helpful and necessary. This paper mainly introduces a method to build a simulation model for the power distribution system, which is based on detailed component models. The power distribution system model consists of power generation unit, transformer rectifier unit, DC-DC converter unit, and DC-AC inverter unit. In order to optimize the performance of the power distribution system and improve the quality of the distributed power, a feedback control network is designed based on the characteristics of the power distribution system. The simulation result indicates that this new simulation model is well designed and it works accurately. Moreover, steady state performance and transient state performance of the model can fulfill the requirements of aircraft power distribution system in the realistic application.

  13. Multistage and multiobjective formulations of globally optimal upgradable expansions for electric power distribution systems

    Science.gov (United States)

    Vaziri Yazdi Pin, Mohammad

    Electric power distribution systems are the last high voltage link in the chain of production, transport, and delivery of the electric energy, the fundamental goals of which are to supply the users' demand safely, reliably, and economically. The number circuit miles traversed by distribution feeders in the form of visible overhead or imbedded underground lines, far exceed those of all other bulk transport circuitry in the transmission system. Development and expansion of the distribution systems, similar to other systems, is directly proportional to the growth in demand and requires careful planning. While growth of electric demand has recently slowed through efforts in the area of energy management, the need for a continued expansion seems inevitable for the near future. Distribution system and expansions are also independent of current issues facing both the suppliers and the consumers of electrical energy. For example, deregulation, as an attempt to promote competition by giving more choices to the consumers, while it will impact the suppliers' planning strategies, it cannot limit the demand growth or the system expansion in the global sense. Curiously, despite presence of technological advancements and a 40-year history of contributions in the area, many of the major utilities still relay on experience and resort to rudimentary techniques when planning expansions. A comprehensive literature review of the contributions and careful analyses of the proposed algorithms for distribution expansion, confirmed that the problem is a complex, multistage and multiobjective problem for which a practical solution remains to be developed. In this research, based on the 15-year experience of a utility engineer, the practical expansion problem has been clearly defined and the existing deficiencies in the previous work identified and analyzed. The expansion problem has been formulated as a multistage planning problem in line with a natural course of development and industry

  14. Draft environmental impact statement for construction and operation of the proposed Bangor Hydro-Electric Company`s second 345-kV transmission tie line to New Brunswick

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-10-01

    This Draft Environmental Impact Statement (DEIS) was prepared by the US Department of Energy (US DOE). The proposed action is the issuance of Presidential Permit PP-89 by DOE to Bangor Hydro-Electric Company to construct and operate a new international transmission line interconnection to New Brunswick, Canada that would consist of an 83.8 mile (US portion), 345-kilovolt (kV) alternating current transmission line from the US-Canadian border at Baileyville, Maine to an existing substation at Orrington, Maine. The principal environmental impacts of the construction and operation of the transmission line would be incremental in nature and would include the conversion of forested uplands (mostly commercial timberlands) and wetlands to right-of-way (small trees, shrubs, and herbaceous vegetation). The proposed line would also result in localized minor to moderate visual impacts and would contribute a minor incremental increase in the exposure of some individuals to electromagnetic fields. This DEIS documents the purpose and need for the proposed action, describes the proposed action and alternatives considered and provides a comparison of the proposed and alternatives routes, and provides detailed information on analyses of the environmental consequences of the proposed action and alternatives, as well as mitigative measures to minimize impacts.

  15. Modeling of Potential Distribution of Electrical Capacitance Tomography Sensor for Multiphase Flow Image

    Directory of Open Access Journals (Sweden)

    S. Sathiyamoorthy

    2007-09-01

    Full Text Available Electrical Capacitance Tomography (ECT was used to develop image of various multi phase flow of gas-liquid-solid in a closed pipe. The principal difficulties to obtained real time image from ECT sensor are permittivity distribution across the plate and capacitance is nonlinear; the electric field is distorted by the material present and is also sensitive to measurement errors and noise. This work present a detailed description is given on method employed for image reconstruction from the capacitance measurements. The discretization and iterative algorithm is developed for improving the predictions with minimum error. The author analyzed eight electrodes square sensor ECT system with two-phase water-gas and solid-gas.

  16. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Directory of Open Access Journals (Sweden)

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  17. High-Lift Propeller System Configuration Selection for NASA's SCEPTOR Distributed Electric Propulsion Flight Demonstrator

    Science.gov (United States)

    Patterson, Michael D.; Derlaga, Joseph M.; Borer, Nicholas K.

    2016-01-01

    Although the primary function of propellers is typically to produce thrust, aircraft equipped with distributed electric propulsion (DEP) may utilize propellers whose main purpose is to act as a form of high-lift device. These \\high-lift propellers" can be placed upstream of wing such that, when the higher-velocity ow in the propellers' slipstreams interacts with the wing, the lift is increased. This technique is a main design feature of a new NASA advanced design project called Scalable Convergent Electric Propulsion Technology Operations Research (SCEPTOR). The goal of the SCEPTOR project is design, build, and y a DEP aircraft to demonstrate that such an aircraft can be much more ecient than conventional designs. This paper provides details into the high-lift propeller system con guration selection for the SCEPTOR ight demonstrator. The methods used in the high-lift propeller system conceptual design and the tradeo s considered in selecting the number of propellers are discussed.

  18. RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    N. Ramirez

    2004-12-16

    A design requirement probability of 0.01 or less in a 4-hour period ensures that the nuclear heating, ventilation, and air-conditioning (HVAC) system in the primary confinement areas of the Dry Transfer Facilities (DTFs) and Fuel Handling Facility (FHF) is working during a Category 1 drop event involving commercial spent nuclear fuel (CSNF) assemblies (BSC 2004a , Section 5.1.1.48). This corresponds to an hourly HVAC failure rate of 2.5E-3 per hour or less, which is contributed to by two dominant causes: equipment failure and loss of electrical power. Meeting this minimum threshold ensures that a Category 1 initiating event followed by the failure of HVAC is a Category 2 event sequence. The two causes for the loss of electrical power include the loss of offsite power and the loss of onsite power distribution. Thus, in order to meet the threshold requirement aforementioned, the failure rate of mechanical equipment, loss of offsite power, and loss of onsite power distribution must be less than or equal to 2.5E-3 per hour for the nuclear HVAC system in the primary confinement areas of the DTFs and FHF. The loss of offsite power occurs at a frequency of 1.1E-5 per hour (BSC 2004a, Section 5.1.1.48). The purpose of this analysis is to determine the probability of occurrence of the unavailability of the nuclear HVAC system in the primary confinement areas of the DTFs and FHF due to loss of electrical power. In addition, this analysis provides insights on the contribution to the unavailability of the HVAC system due to equipment failure. The scope of this analysis is limited to finding the frequency of loss of electrical power to the nuclear HVAC system in the primary confinement areas of the DTFs and FHF.

  19. A Power Load Distribution Algorithm to Optimize Data Center Electrical Flow

    Directory of Open Access Journals (Sweden)

    Paulo Maciel

    2013-07-01

    Full Text Available Energy consumption is a matter of common concern in the world today. Research demonstrates that as a consequence of the constantly evolving and expanding field of information technology, data centers are now major consumers of electrical energy. Such high electrical energy consumption emphasizes the issues of sustainability and cost. Against this background, the present paper proposes a power load distribution algorithm (PLDA to optimize energy distribution of data center power infrastructures. The PLDA, which is based on the Ford-Fulkerson algorithm, is supported by an environment called ASTRO, capable of performing the integrated evaluation of dependability, cost and sustainability. More specifically, the PLDA optimizes the flow distribution of the energy flow model (EFM. EFMs are responsible for estimating sustainability and cost issues of data center infrastructures without crossing the restrictions of the power capacity that each device can provide (power system or extract (cooling system. Additionally, a case study is presented that analyzed seven data center power architectures. Significant results were observed, achieving a reduction in power consumption of up to 15.5%.

  20. Reliability measurement for mixed mode failures of 33/11 kilovolt electric power distribution stations.

    Science.gov (United States)

    Alwan, Faris M; Baharum, Adam; Hassan, Geehan S

    2013-01-01

    The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter [Formula: see text] and shape parameters [Formula: see text] and [Formula: see text]. Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models.

  1. Reliability measurement for mixed mode failures of 33/11 kilovolt electric power distribution stations.

    Directory of Open Access Journals (Sweden)

    Faris M Alwan

    Full Text Available The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter [Formula: see text] and shape parameters [Formula: see text] and [Formula: see text]. Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models.

  2. Development of a Wireless Sensor Network for Distributed Measurement of Total Electric Field under HVDC Transmission Lines

    OpenAIRE

    Yong Cui; Jianxun Lv; Haiwen Yuan; Luxing Zhao; Yingyi Liu; Hao Yang

    2014-01-01

    A wireless sensor network-based distributed measurement system is designed for collecting and monitoring the electric field under the high voltage direct current (HVDC) transmission lines. The proposed system architecture is composed of a group of wireless nodes connected with electric field sensors and a base station. The electric field sensor based on Gauss’s law is elaborated and developed. For the design of wireless node, the ARM microprocessor and Zigbee radio frequency module are employ...

  3. Algorithm and Program for Calculation and Analysis of Modes and Losses of Electric Energy in Electricity Distribution Networks of 6–20 kV

    Directory of Open Access Journals (Sweden)

    M. Fursanov

    2013-01-01

    Full Text Available A refined mathematical model and algorithm for operative control of the modes and detection of energy loss sites in electricity distribution networks of 6–20 kV have been developed in the paper. The developed software program can be used for testing other technical solutions and computer programs pertaining to the area of research and it is considered as one of the most important components applied for creation of intellectual electric networks.

  4. Operational and Environmental Efficiencies of Japanese Electric Power Companies from 2003 to 2015: Influence of Market Reform and Fukushima Nuclear Power Accident

    Directory of Open Access Journals (Sweden)

    Mika Goto

    2017-01-01

    Full Text Available This study measures operational and environmental efficiencies of nine incumbent electric power companies (EPCos in Japan and examines an influence of market reform and Fukushima nuclear power plant accident on efficiencies using a data set from 2003 to 2015. This study applies output-oriented radial data envelopment analysis (DEA model to the measurement of efficiencies. Three inputs and three desirable outputs are used for the measurement of operational efficiency, and one undesirable output besides inputs and desirable outputs is used to measure environmental efficiency. EPCos produce not only desirable output, for example, electricity, but also undesirable output, for example, CO2, for their operations. For the measurement of environmental efficiency, this study uses a unique DEA model that assumes occurrence of ecotechnology innovation. The results reveal that environmental efficiency of EPCos is mostly invariant over the period of this study, while operational efficiency decreases in the same period. In addition, the results present that Japanese EPCos make efforts to reduce CO2 emissions by promoting ecotechnology innovation. The Kruskal–Wallis rank sum test indicates differences in operational and environmental efficiencies among EPCos. Such performance differences might become larger as market liberalization advances, which could lead to further structural changes of the industry.

  5. Combining Market-Based Control with Distribution Grid Constraints when Coordinating Electric Vehicle Charging

    Directory of Open Access Journals (Sweden)

    Geert Deconinck

    2015-12-01

    Full Text Available The charging of electric vehicles (EVs impacts the distribution grid, and its cost depends on the price of electricity when charging. An aggregator that is responsible for a large fleet of EVs can use a market-based control algorithm to coordinate the charging of these vehicles, in order to minimize the costs. In such an optimization, the operational parameters of the distribution grid, to which the EVs are connected, are not considered. This can lead to violations of the technical constraints of the grid (e.g., under-voltage, phase unbalances; for example, because many vehicles start charging simultaneously when the price is low. An optimization that simultaneously takes the economic and technical aspects into account is complex, because it has to combine time-driven control at the market level with event-driven control at the operational level. Different case studies investigate under which circumstances the market-based control, which coordinates EV charging, conflicts with the operational constraints of the distribution grid. Especially in weak grids, phase unbalance and voltage issues arise with a high share of EVs. A low-level voltage droop controller at the charging point of the EV can be used to avoid many grid constraint violations, by reducing the charge power if the local voltage is too low. While this action implies a deviation from the cost-optimal operating point, it is shown that this has a very limited impact on the business case of an aggregator, and is able to comply with the technical distribution grid constraints, even in weak distribution grids with many EVs.

  6. Computational Analysis of a Wing Designed for the X-57 Distributed Electric Propulsion Aircraft

    Science.gov (United States)

    Deere, Karen A.; Viken, Jeffrey K.; Viken, Sally A.; Carter, Melissa B.; Wiese, Michael R.; Farr, Norma L.

    2017-01-01

    A computational study of the wing for the distributed electric propulsion X-57 Maxwell airplane configuration at cruise and takeoff/landing conditions was completed. Two unstructured-mesh, Navier-Stokes computational fluid dynamics methods, FUN3D and USM3D, were used to predict the wing performance. The goal of the X-57 wing and distributed electric propulsion system design was to meet or exceed the required lift coefficient 3.95 for a stall speed of 58 knots, with a cruise speed of 150 knots at an altitude of 8,000 ft. The X-57 Maxwell airplane was designed with a small, high aspect ratio cruise wing that was designed for a high cruise lift coefficient (0.75) at angle of attack of 0deg. The cruise propulsors at the wingtip rotate counter to the wingtip vortex and reduce induced drag by 7.5 percent at an angle of attack of 0.6deg. The unblown maximum lift coefficient of the high-lift wing (with the 30deg flap setting) is 2.439. The stall speed goal performance metric was confirmed with a blown wing computed effective lift coefficient of 4.202. The lift augmentation from the high-lift, distributed electric propulsion system is 1.7. The predicted cruise wing drag coefficient of 0.02191 is 0.00076 above the drag allotted for the wing in the original estimate. However, the predicted drag overage for the wing would only use 10.1 percent of the original estimated drag margin, which is 0.00749.

  7. Design of driving control strategy of torque distribution for two - wheel independent drive electric vehicle

    Science.gov (United States)

    Zhang, Chuanwei; Zhang, Dongsheng; Wen, Jianping

    2018-02-01

    In order to coordinately control the torque distribution of existing two-wheel independent drive electric vehicle, and improve the energy efficiency and control stability of the whole vehicle, the control strategies based on fuzzy control were designed which adopt the direct yaw moment control as the main line. For realizing the torque coordination simulation of the two-wheel independent drive vehicle, the vehicle model, motor model and tire model were built, including the vehicle 7 - DOF dynamics model, motion equation, torque equation. Finally, in the Carsim - Simulink joint simulation platform, the feasibility of the drive control strategy was verified.

  8. Thermal stress comparison in modular power converter topologies for smart transformers in the electrical distribution system

    DEFF Research Database (Denmark)

    Andresen, Markus; Ma, Ke; Liserre, Marco

    2015-01-01

    A Smart Transformer (ST) can cover an important managing role in the future electrical distribution grid. For the moment, the reliability and cost are not competitive with traditional transformers and create a barrier for its application. This work conduct detail designs and analysis...... for a promising modular ST solution, which is composed of Modular Multi-level converter, Quad Active Bridge DC-DC converters, and two-level voltage source converters. The focus is put on the loading conditions and thermal stress of power semiconductor devices in order to discover critical parts of the whole...

  9. Simultaneous reconstruction of outer boundary shape and conductivity distribution in electrical impedance tomography

    KAUST Repository

    Hyvönen, Nuutti

    2016-01-05

    The simultaneous retrieval of the exterior boundary shape and the interior admittivity distribution of an examined body in electrical impedance tomography is considered. The reconstruction method is built for the complete electrode model and it is based on the Frechet derivative of the corresponding current-to-voltage map with respect to the body shape. The reconstruction problem is cast into the Bayesian framework, and maximum a posteriori estimates for the admittivity and the boundary geometry are computed. The feasibility of the approach is evaluated by experimental data from water tank measurements.

  10. A Predictive Distribution Model for Cooperative Braking System of an Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Hongqiang Guo

    2014-01-01

    Full Text Available A predictive distribution model for a series cooperative braking system of an electric vehicle is proposed, which can solve the real-time problem of the optimum braking force distribution. To get the predictive distribution model, firstly three disciplines of the maximum regenerative energy recovery capability, the maximum generating efficiency and the optimum braking stability are considered, then an off-line process optimization stream is designed, particularly the optimal Latin hypercube design (Opt LHD method and radial basis function neural network (RBFNN are utilized. In order to decouple the variables between different disciplines, a concurrent subspace design (CSD algorithm is suggested. The established predictive distribution model is verified in a dynamic simulation. The off-line optimization results show that the proposed process optimization stream can improve the regenerative energy recovery efficiency, and optimize the braking stability simultaneously. Further simulation tests demonstrate that the predictive distribution model can achieve high prediction accuracy and is very beneficial for the cooperative braking system.

  11. 3D ion velocity distribution function measurement in an electric thruster using laser induced fluorescence tomography.

    Science.gov (United States)

    Elias, P Q; Jarrige, J; Cucchetti, E; Cannat, F; Packan, D

    2017-09-01

    Measuring the full ion velocity distribution function (IVDF) by non-intrusive techniques can improve our understanding of the ionization processes and beam dynamics at work in electric thrusters. In this paper, a Laser-Induced Fluorescence (LIF) tomographic reconstruction technique is applied to the measurement of the IVDF in the plume of a miniature Hall effect thruster. A setup is developed to move the laser axis along two rotation axes around the measurement volume. The fluorescence spectra taken from different viewing angles are combined using a tomographic reconstruction algorithm to build the complete 3D (in phase space) time-averaged distribution function. For the first time, this technique is used in the plume of a miniature Hall effect thruster to measure the full distribution function of the xenon ions. Two examples of reconstructions are provided, in front of the thruster nose-cone and in front of the anode channel. The reconstruction reveals the features of the ion beam, in particular on the thruster axis where a toroidal distribution function is observed. These findings are consistent with the thruster shape and operation. This technique, which can be used with other LIF schemes, could be helpful in revealing the details of the ion production regions and the beam dynamics. Using a more powerful laser source, the current implementation of the technique could be improved to reduce the measurement time and also to reconstruct the temporal evolution of the distribution function.

  12. 3D ion velocity distribution function measurement in an electric thruster using laser induced fluorescence tomography

    Science.gov (United States)

    Elias, P. Q.; Jarrige, J.; Cucchetti, E.; Cannat, F.; Packan, D.

    2017-09-01

    Measuring the full ion velocity distribution function (IVDF) by non-intrusive techniques can improve our understanding of the ionization processes and beam dynamics at work in electric thrusters. In this paper, a Laser-Induced Fluorescence (LIF) tomographic reconstruction technique is applied to the measurement of the IVDF in the plume of a miniature Hall effect thruster. A setup is developed to move the laser axis along two rotation axes around the measurement volume. The fluorescence spectra taken from different viewing angles are combined using a tomographic reconstruction algorithm to build the complete 3D (in phase space) time-averaged distribution function. For the first time, this technique is used in the plume of a miniature Hall effect thruster to measure the full distribution function of the xenon ions. Two examples of reconstructions are provided, in front of the thruster nose-cone and in front of the anode channel. The reconstruction reveals the features of the ion beam, in particular on the thruster axis where a toroidal distribution function is observed. These findings are consistent with the thruster shape and operation. This technique, which can be used with other LIF schemes, could be helpful in revealing the details of the ion production regions and the beam dynamics. Using a more powerful laser source, the current implementation of the technique could be improved to reduce the measurement time and also to reconstruct the temporal evolution of the distribution function.

  13. Rényi entropies of electrical transmission lines with Fibonacci distribution of inductances

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, E., E-mail: elazo@uta.cl [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile); Mellado, F. [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile); Escuela Universitaria de Ingeniería Eléctrica-Electrónica, Universidad de Tarapacá, Arica (Chile); Saavedra, E. [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile)

    2012-10-01

    We study classical dual transmission lines with constant capacitances C{sub j}=C{sub 0}, ∀j, when we distribute two inductance values L{sub A} and L{sub B} according to the Fibonacci sequence. Using the electric current function I{sub j}(ω), we study the normalized localization length Λ(ω), the Rényi entropies R{sub m}(ω) and the normalized information length β(ω). We found three kinds of behavior of the I{sub j}(ω) function: localized, extended and intermediate. In addition, it is found that the transmission line with Fibonacci distribution of inductances shows a behavior characteristic of quasi-periodic systems, namely, a self-similar frequency spectrum, where each subband is divided into three subbands, but the number of global subbands is greater than four.

  14. Optimal investment and scheduling of distributed energy resources with uncertainty in electric vehicles driving schedules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Goncalo [Technical Univ. of Lisbon (Portugal); Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Center for Energy and Innovation Technologies (Austria); Bozchalui, Mohammed C. [NEC Laboratories American Inc., Irving, TX (United States); Sharma, Ratnesh [NEC Laboratories American Inc., Irving, TX (United States); Marnay, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Barbosa-Povoa, Ana [Technical Univ. of Lisbon (Portugal); Ferrao, Paulo [Technical Univ. of Lisbon (Portugal)

    2013-12-06

    The large scale penetration of electric vehicles (EVs) will introduce technical challenges to the distribution grid, but also carries the potential for vehicle-to-grid services. Namely, if available in large enough numbers, EVs can be used as a distributed energy resource (DER) and their presence can influence optimal DER investment and scheduling decisions in microgrids. In this work, a novel EV fleet aggregator model is introduced in a stochastic formulation of DER-CAM [1], an optimization tool used to address DER investment and scheduling problems. This is used to assess the impact of EV interconnections on optimal DER solutions considering uncertainty in EV driving schedules. Optimization results indicate that EVs can have a significant impact on DER investments, particularly if considering short payback periods. Furthermore, results suggest that uncertainty in driving schedules carries little significance to total energy costs, which is corroborated by results obtained using the stochastic formulation of the problem.

  15. Supporting involvement of electric vehicles in distribution grids: Lowering the barriers for a proactive integration

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Zecchino, Antonio

    2017-01-01

    where active distribution grid management schemes are still to be developed, it is important to recognise the barriers for active EV involvement in the early stage of the development. This manuscript focuses on identifying these barriers from a technology and infrastructure perspective as well as from......Increasing environmental concerns are driving an evolution of the energy system in which electric vehicles (EVs) play an important role. Still, as the EV number increases, the adverse impact of charging is observed more widely, especially at the low-voltage level where high EV concentrations cause...... various detrimental effects due to the coincidence between EV charging and residential peak load. However, if managed properly, EVs become flexible resources which can improve the system operation, making them an attractive asset for the distribution system operator. With the recent technology development...

  16. Extension of the Accurate Voltage-Sag Fault Location Method in Electrical Power Distribution Systems

    Directory of Open Access Journals (Sweden)

    Youssef Menchafou

    2016-03-01

    Full Text Available Accurate Fault location in an Electric Power Distribution System (EPDS is important in maintaining system reliability. Several methods have been proposed in the past. However, the performances of these methods either show to be inefficient or are a function of the fault type (Fault Classification, because they require the use of an appropriate algorithm for each fault type. In contrast to traditional approaches, an accurate impedance-based Fault Location (FL method is presented in this paper. It is based on the voltage-sag calculation between two measurement points chosen carefully from the available strategic measurement points of the line, network topology and current measurements at substation. The effectiveness and the accuracy of the proposed technique are demonstrated for different fault types using a radial power flow system. The test results are achieved from the numerical simulation using the data of a distribution line recognized in the literature.

  17. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    Science.gov (United States)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a

  18. Distributed energy storage systems on the basis of electric-vehicle fleets

    Science.gov (United States)

    Zhuk, A. Z.; Buzoverov, E. A.; Sheindlin, A. E.

    2015-01-01

    Several power technologies directed to solving the problem of covering nonuniform loads in power systems are developed at the Joint Institute of High Temperatures, Russian Academy of Sciences (JIHT RAS). One direction of investigations is the use of storage batteries of electric vehicles to compensate load peaks in the power system (V2G—vehicle-to-grid technology). The efficiency of energy storage systems based on electric vehicles with traditional energy-saving technologies is compared in the article by means of performing computations. The comparison is performed by the minimum-cost criterion for the peak energy supply to the system. Computations show that the distributed storage systems based on fleets of electric cars are efficient economically with their usage regime to 1 h/day. In contrast to traditional methods, the prime cost of regulation of the loads in the power system based on V2G technology is independent of the duration of the load compensation period (the duration of the consumption peak).

  19. Electrical Resistivity Investigation of Gas Hydrate Distribution in Mississippi Canyon Block 118, Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Dunbar, John

    2012-12-31

    Electrical methods offer a geophysical approach for determining the sub-bottom distribution of hydrate in deep marine environments. Methane hydrate is essentially non-conductive. Hence, sediments containing hydrate are more resistive than sediments without hydrates. To date, the controlled source electromagnetic (CSEM) method has been used in marine hydrates studies. This project evaluated an alternative electrical method, direct current resistivity (DCR), for detecting marine hydrates. DCR involves the injection of direct current between two source electrodes and the simultaneous measurement of the electric potential (voltage) between multiple receiver electrodes. The DCR method provides subsurface information comparable to that produced by the CSEM method, but with less sophisticated instrumentation. Because the receivers are simple electrodes, large numbers can be deployed to achieve higher spatial resolution. In this project a prototype seafloor DCR system was developed and used to conduct a reconnaissance survey at a site of known hydrate occurrence in Mississippi Canyon Block 118. The resulting images of sub-bottom resistivities indicate that high-concentration hydrates at the site occur only in the upper 50 m, where deep-seated faults intersect the seafloor. Overall, there was evidence for much less hydrate at the site than previously thought based on available seismic and CSEM data alone.

  20. Spectral distribution of local field potential responses to electrical stimulation of the retina.

    Science.gov (United States)

    Wong, Yan T; Halupka, Kerry; Kameneva, Tatiana; Cloherty, Shaun L; Grayden, David B; Burkitt, Anthony N; Meffin, Hamish; Shivdasani, Mohit N

    2016-06-01

    Different frequency bands of the local field potential (LFP) have been shown to reflect neuronal activity occurring at varying cortical scales. As such, recordings of the LFP may offer a novel way to test the efficacy of neural prostheses and allow improvement of stimulation strategies via neural feedback. Here we use LFP measurements from visual cortex to characterize neural responses to electrical stimulation of the retina. We aim to show that the LFP is a viable signal that contains sufficient information to optimize the performance of sensory neural prostheses. Clinically relevant electrode arrays were implanted in the suprachoroidal space of one eye in four felines. LFPs were simultaneously recorded in response to stimulation of individual electrodes using penetrating microelectrode arrays from the visual cortex. The frequency response of each electrode was extracted using multi-taper spectral analysis and the uniqueness of the responses was determined via a linear decoder. We found that cortical LFPs are reliably modulated by electrical stimulation of the retina and that the responses are spatially localized. We further characterized the spectral distribution of responses, with maximum information being contained in the low and high gamma bands. Finally, we found that LFP responses are unique to a large range of stimulus parameters (∼40) with a maximum conveyable information rate of 6.1 bits. These results show that the LFP can be used to validate responses to electrical stimulation of the retina and we provide the first steps towards using these responses to provide more efficacious stimulation strategies.

  1. Parametric study of prospective early commercial MHD power plants (PSPEC). General Electric Company, task 1: Parametric analysis

    Science.gov (United States)

    Marston, C. H.; Alyea, F. N.; Bender, D. J.; Davis, L. K.; Dellinger, T. C.; Hnat, J. G.; Komito, E. H.; Peterson, C. A.; Rogers, D. A.; Roman, A. J.

    1980-01-01

    The performance and cost of moderate technology coal-fired open cycle MHD/steam power plant designs which can be expected to require a shorter development time and have a lower development cost than previously considered mature OCMHD/steam plants were determined. Three base cases were considered: an indirectly-fired high temperature air heater (HTAH) subsystem delivering air at 2700 F, fired by a state of the art atmospheric pressure gasifier, and the HTAH subsystem was deleted and oxygen enrichment was used to obtain requisite MHD combustion temperature. Coal pile to bus bar efficiencies in ease case 1 ranged from 41.4% to 42.9%, and cost of electricity (COE) was highest of the three base cases. For base case 2 the efficiency range was 42.0% to 45.6%, and COE was lowest. For base case 3 the efficiency range was 42.9% to 44.4%, and COE was intermediate. The best parametric cases in bases cases 2 and 3 are recommended for conceptual design. Eventual choice between these approaches is dependent on further evaluation of the tradeoffs among HTAH development risk, O2 plant integration, and further refinements of comparative costs.

  2. COMPARISON OF BACTERIAL FORAGING OPTIMIZATION AND ARTIFICIAL BEE COLONY OPTIMIZATION TECHNIQUE FOR DISTRIBUTED GENERATION SIZING AND PLACEMENT IN AN ELECTRICAL DISTRIBUTION SYSTEM

    OpenAIRE

    J. A. Baskar*, Dr. R. Hariprakash (IITM), Dr. M. Vijayakumar

    2017-01-01

    Integration of Distributed Generation (DG) in an electrical distribution system has increased recently due to voltage improvement, line loss reduction, environmental advantages, and postponement of system upgrading, and increasing reliability. Improper location and capacity of DG may affect the voltage stability on the Distribution System (DS). Optimization techniques are tools used to predict size and locate the DG units in the system, so as to utilize these units optimally within certain li...

  3. High-Lift Propeller Noise Prediction for a Distributed Electric Propulsion Flight Demonstrator

    Science.gov (United States)

    Nark, Douglas M.; Buning, Pieter G.; Jones, William T.; Derlaga, Joseph M.

    2017-01-01

    Over the past several years, the use of electric propulsion technologies within aircraft design has received increased attention. The characteristics of electric propulsion systems open up new areas of the aircraft design space, such as the use of distributed electric propulsion (DEP). In this approach, electric motors are placed in many different locations to achieve increased efficiency through integration of the propulsion system with the airframe. Under a project called Scalable Convergent Electric Propulsion Technology Operations Research (SCEPTOR), NASA is designing a flight demonstrator aircraft that employs many "high-lift propellers" distributed upstream of the wing leading edge and two cruise propellers (one at each wingtip). As the high-lift propellers are operational at low flight speeds (take-off/approach flight conditions), the impact of the DEP configuration on the aircraft noise signature is also an important design consideration. This paper describes efforts toward the development of a mulit-fidelity aerodynamic and acoustic methodology for DEP high-lift propeller aeroacoustic modeling. Specifically, the PAS, OVERFLOW 2, and FUN3D codes are used to predict the aerodynamic performance of a baseline high-lift propeller blade set. Blade surface pressure results from the aerodynamic predictions are then used with PSU-WOPWOP and the F1A module of the NASA second generation Aircraft NOise Prediction Program to predict the isolated high-lift propeller noise source. Comparisons of predictions indicate that general trends related to angle of attack effects at the blade passage frequency are captured well with the various codes. Results for higher harmonics of the blade passage frequency appear consistent for the CFD based methods. Conversely, evidence of the need for a study of the effects of increased azimuthal grid resolution on the PAS based results is indicated and will be pursued in future work. Overall, the results indicate that the computational

  4. 76 FR 52215 - Airworthiness Directives; General Electric Company CF34-10E2A1; CF34-10E5; CF34-10E5A1; CF34-10E6...

    Science.gov (United States)

    2011-08-22

    ... issuing this AD to prevent high-cycle fatigue cracking of the fan rotor spinner support attachment lugs... Electric Company CF34-10E turbofan engine experiencing high fan frame vibrations led to removal of the fan.... The cause of the vibration was determined to be a non-synchronous vibration induced by a spinner...

  5. Improving the cooling performance of electrical distribution transformer using transformer oil – Based MEPCM suspension

    Directory of Open Access Journals (Sweden)

    Mushtaq Ismael Hasan

    2017-04-01

    Full Text Available In this paper the electrical distribution transformer has been studied numerically and the effect of outside temperature on its cooling performance has been investigated. The temperature range studied covers the hot climate regions. 250 KVA distribution transformer is chosen as a study model. A novel cooling fluid is proposed to improve the cooling performance of this transformer, transformer oil-based microencapsulated phase change materials suspension is used with volume concentration (5–25% as a cooling fluid instead of pure transformer oil. Paraffin wax is used as a phase change material to make the suspension, in addition to the ability of heat absorption due to melting, the paraffin wax considered as a good electrical insulator. Results obtained show that, using of MEPCM suspension instead of pure transformer oil lead to improve the cooling performance of transformer by reducing its temperature and as a consequence increasing its protection against the breakdown. The melting fraction increased with increasing outside temperature up to certain temperature after which the melting fraction reach maximum constant value (MF = 1 which indicate that, the choosing of PCM depend on the environment in which the transformer is used.

  6. Assessing the Potential of Plug-in Electric Vehicles in Active Distribution Networks

    Directory of Open Access Journals (Sweden)

    Reza Ahmadi Kordkheili

    2016-01-01

    Full Text Available A multi-objective optimization algorithm is proposed in this paper to increase the penetration level of renewable energy sources (RESs in distribution networks by intelligent management of plug-in electric vehicle (PEV storage. The proposed algorithm is defined to manage the reverse power flow (PF from the distribution network to the upstream electrical system. Furthermore, a charging algorithm is proposed within the proposed optimization in order to assure PEV owner’s quality of service (QoS. The method uses genetic algorithm (GA to increase photovoltaic (PV penetration without jeopardizing PEV owners’ (QoS and grid operating limits, such as voltage level of the grid buses. The method is applied to a part of the Danish low voltage (LV grid to evaluate its effectiveness and capabilities. Different scenarios have been defined and tested using the proposed method. Simulation results demonstrate the capability of the algorithm in increasing solar power penetration in the grid up to 50%, depending on the PEV penetration level and the freedom of the system operator in managing the available PEV storage.

  7. Computational Analysis of Powered Lift Augmentation for the LEAPTech Distributed Electric Propulsion Wing

    Science.gov (United States)

    Deere, Karen A.; Viken, Sally A.; Carter, Melissa B.; Viken, Jeffrey K.; Wiese, Michael R.; Farr, Norma L.

    2017-01-01

    A computational study of a distributed electric propulsion wing with a 40deg flap deflection has been completed using FUN3D. Two lift-augmentation power conditions were compared with the power-off configuration on the high-lift wing (40deg flap) at a 73 mph freestream flow and for a range of angles of attack from -5 degrees to 14 degrees. The computational study also included investigating the benefit of corotating versus counter-rotating propeller spin direction to powered-lift performance. The results indicate a large benefit in lift coefficient, over the entire range of angle of attack studied, by using corotating propellers that all spin counter to the wingtip vortex. For the landing condition, 73 mph, the unpowered 40deg flap configuration achieved a maximum lift coefficient of 2.3. With high-lift blowing the maximum lift coefficient increased to 5.61. Therefore, the lift augmentation is a factor of 2.4. Taking advantage of the fullspan lift augmentation at similar performance means that a wing powered with the distributed electric propulsion system requires only 42 percent of the wing area of the unpowered wing. This technology will allow wings to be 'cruise optimized', meaning that they will be able to fly closer to maximum lift over drag conditions at the design cruise speed of the aircraft.

  8. Nonparametric Tree-Based Predictive Modeling of Storm Outages on an Electric Distribution Network.

    Science.gov (United States)

    He, Jichao; Wanik, David W; Hartman, Brian M; Anagnostou, Emmanouil N; Astitha, Marina; Frediani, Maria E B

    2017-03-01

    This article compares two nonparametric tree-based models, quantile regression forests (QRF) and Bayesian additive regression trees (BART), for predicting storm outages on an electric distribution network in Connecticut, USA. We evaluated point estimates and prediction intervals of outage predictions for both models using high-resolution weather, infrastructure, and land use data for 89 storm events (including hurricanes, blizzards, and thunderstorms). We found that spatially BART predicted more accurate point estimates than QRF. However, QRF produced better prediction intervals for high spatial resolutions (2-km grid cells and towns), while BART predictions aggregated to coarser resolutions (divisions and service territory) more effectively. We also found that the predictive accuracy was dependent on the season (e.g., tree-leaf condition, storm characteristics), and that the predictions were most accurate for winter storms. Given the merits of each individual model, we suggest that BART and QRF be implemented together to show the complete picture of a storm's potential impact on the electric distribution network, which would allow for a utility to make better decisions about allocating prestorm resources. © 2016 Society for Risk Analysis.

  9. Probabilistic Harmonic Calculation in Distribution Networks with Electric Vehicle Charging Stations

    Directory of Open Access Journals (Sweden)

    Jianxue Wang

    2014-01-01

    Full Text Available Integrating EV charging station into power grid will bring impacts on power system, among which the most significant one is the harmonic pollution on distribution networks. Due to the uncertainty of the EV charging process, the harmonic currents brought by EV charging stations have a random nature. This paper proposed a mathematical simulation method for studying the working status of charging stations, which considers influencing factors including random leaving factor, electricity price, and waiting time. Based on the proposed simulation method, the probability distribution of the harmonic currents of EV charging stations is obtained and used in the calculation of the probability harmonic power flow. Then the impacts of EVs and EV charging stations on distribution networks can be analyzed. In the case study, the proposed simulation and analysis method is implemented on the IEEE-34 distribution network. The influences of EV arrival rates, the penetration rate, and the accessing location of EV charging station are also investigated. Results show that this research has good potential in guiding the planning and construction of charging station.

  10. Electric field and space-charge distribution in SI GaAs: effect of high-energy proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Castaldini, A.; Cavallini, A. E-mail: anna.cavallini@bo.infn.it; Polenta, L.; Canali, C.; Nava, F

    1999-04-21

    The effect of irradiation on semi-insulating gallium arsenide Schottky diodes has been investigated by means of surface potential measurements and spectroscopic techniques. Before and after irradiation the electric field exhibits a Mott barrier-like distribution, and the box-shaped space charge modifies its distribution with irradiation. The increase in density or the generation of some traps changes the compensation ratio producing a deeper active region and a more homogeneous distribution of the electric field. The latter phenomenon is also observed by EBIC images of edge-mounted diodes.

  11. Electric field and space-charge distribution in SI GaAs: effect of high-energy proton irradiation

    CERN Document Server

    Castaldini, A; Polenta, L; Canali, C; Nava, F

    1999-01-01

    The effect of irradiation on semi-insulating gallium arsenide Schottky diodes has been investigated by means of surface potential measurements and spectroscopic techniques. Before and after irradiation the electric field exhibits a Mott barrier-like distribution, and the box-shaped space charge modifies its distribution with irradiation. The increase in density or the generation of some traps changes the compensation ratio producing a deeper active region and a more homogeneous distribution of the electric field. The latter phenomenon is also observed by EBIC images of edge-mounted diodes.

  12. Project of law relative to the electricity and gas public utilities and to the power and gas companies; Projet de loi relatif au service public de l'electricite et du gaz et aux entreprises electriques et gazieres

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This document is the definitive text of this project of law adopted by the French house of commons. The aim of this law is to allow the administrations to avoid to use their eligibility right with the opening of the electricity and gas markets to competition. It changes the juridical status of the two public utilities Electricite de France (EdF) and Gaz de France (GdF) into two anonymous companies and creates two additional companies for the management of the power and gas networks. It ensures also the transposition of the European directives from June 26, 2003 (2003/54/CE and 2003/55/CE). It contains some proper dispositions and modifies various existing French laws, in particular the law no. 46-628 from April 8, 1946 about the electricity and gas nationalization and the law no. 2000-108 from February 10, 2000 relative to the modernization and development of the electric public utility. (J.S.)

  13. Importance of information about distribution for assuring secured and safe food! : What is food traceability system? Considering from an approach of Mr. Kazuo Sawauchi, Manager, Advanced Automation Company, Yamatake Corporation

    Science.gov (United States)

    Morita, Utako

    Importance of information about distribution for assuring secured and safe food! : What is food traceability system? Considering from an approach of Mr. Kazuo Sawauchi, Manager, Advanced Automation Company, Yamatake Corporation

  14. Development of distributed fiber-optic sensor system for electric power systems 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Soo; Kim, Yo Hee; Oh, Sang Ki; Kim, In Soo; Park, Hae Soo; Roh, Jong Dae [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1996-05-01

    A specific scheme of distributed fiber-optic sensor system for electric power systems is designed in the second year research. A pulsed laser diode driver is designed and optical spectrum distribution of output light of laser diode is analyzed using optical spectrum analyzer. Optical coupler and optic system for selecting a specific wavelength from Raman backscattering light wave are designed. Optical receiving circuit signal processing electronics are designed and tested with 2.2 km length of optical fiber. Experimental results show that optical output power of the backscattering light wave exponentially decay as the tim axis approaches to the fiber end point. Analysis of Raman backscattering wave knows the temperature change of any specified point of optical fiber. The output power of Raman backscattering wave is about 30 db weaker than that of Rayleigh backscattering wave. Research of high speed averaging circuit should be performed for improvement of signal to noise ratio. And, Parallel signal processing algorithm should be adapted to shorten the measuring time of distributed fiber-optic sensor system. (author). 37 refs.

  15. Accelerating the Integration of Distributed Water Solutions: A Conceptual Financing Model from the Electricity Sector

    Science.gov (United States)

    Quesnel, Kimberly J.; Ajami, Newsha K.; Wyss, Noemi

    2017-11-01

    Modern challenges require new approaches to urban water management. One solution in the portfolio of potential strategies is the integration of distributed water infrastructure, practices, and technologies into existing systems. However, many practical barriers have prevented the widespread adoption of these systems in the US. The objective of this paper is to address these challenges by developing a conceptual model encompassing regulatory, financial, and governance components that can be used to incorporate new distributed water solutions into our current network. To construct the model, case studies of successfully implemented distributed electricity systems, specifically energy efficiency and renewable energy technologies, were examined to determine how these solutions have become prominent in recent years and what lessons can be applied to the water sector in a similar pursuit. The proposed model includes four action-oriented elements: catalyzing change, establishing funding sources, using resource pathways, and creating innovative governance structures. As illustrated in the model, the water sector should use suite of coordinated policies to promote change, engage end users through fiscal incentives, and encourage research, development and dissemination of new technologies over time.

  16. Thermoelectric power plant of Iron and Steel Company of Sao Paulo state, Brazil, Planning; Planejamento da central termoeletrica da COSIPA - Companhia Siderurgica Paulista

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Paulo Sergio; Costa, Luiz Orlando; Silva, Clovis Aprigio da; Paiva Borges, Elmar de; Martinez, Francisco Gomes [Companhia Siderurgica Paulista (Brazil)

    1990-02-01

    This paper shows the operational philosophy, control and supervision of the Thermoelectric power plant of the Iron and Steel Company of Sao Paulo state, Brazil, in operations of fuel distribution, steam generation, electric power generation and air flow. 8 tabs.

  17. Development situation of UPS, Sanken Electric Company. Trend of network-compatible technology; Kodo johoka shakai wo sasaeru UPS (Sanken Denki). Network taiogata no gijutsu doko

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T. [Sanken Electric Co. Ltd., Saitama (Japan)

    1997-07-01

    Sanken Electric Company has developed an uninterruptible power system (UPS) and produced it on a commercial scale. In recent years, Sanken has also satisfied the needs for compactness, lightweight, and high performance by using the latest power conversion element and digital control technology. This paper introduces the Sanken`s technology trend of a network-compatible UPS system that is new needs. The following conditions are required for the network-compatible UPS system. A commercial input power noise can be absorbed and the constant-voltage and constant-frequency power can be supplied continuously. A computer can be automatically stopped in safety when the power fails, and life parts can be safely and securely replaced during LAN operation. A battery can be checked for abnormality and can operate according to the system start/stop schedule. A battery can be switched without warning when the power fails. Moreover, a simple network management protocol (SNMP) is provided as the communication function. The UPS system that satisfies these conditions has been produced on a commercial scale. 1 fig., 3 tabs.

  18. Allocation of petroleum feedstock: Baltimore Gas and Electric Company, Sollers Point SNG Plant, Sollers Point, Baltimore County, Maryland. Final environmental impact statement

    Energy Technology Data Exchange (ETDEWEB)

    Liverman, James L.

    1978-04-01

    An allocation of naphtha feedstock up to 2,186,000 barrels per year to Baltimore Gas and Electric Company (BG and E) to operate its synthetic natural gas (SNG) facility is being considered. The allocation would enable BG and E to produce 10,800,000 mcf of SNG during a 180 day period. Operation of the plant at design capacity is expected to result in annual pollution emissions as follows: 626.4 tons of sulfur oxides, 168.5 tons of nitrogen oxides and 21.6 tons of particulate matter. Incremental emissions due to plant operations relative to existing emissions in Baltimore County are less than 1%. All Federal and State air quality standards should be met. Treated effluent is to be discharged into the Patapasco River where the environmental impacts are not expected to be significant. The SNG facility has been designed to be in compliance with all applicable Federal, State and local effluent standards. Water consumption requirements of 335,000 gallons per day are not expected to significantly tax the area's water resources. Sound generated by the SNG facility will be inaudible or imperceptible. All other operational impacts on land use, population, visual quality, roadways, community facilities and services and ecological systems were judged to be minimal. Environmental impacts resulting from various alternatives ranging from full allocation through denial of an allocation are discussed.

  19. Collective control device for Tachibana Bay Thermal Power Plant of Electric Power Development Company; Dengen Kaihatsu (kabu) Tachibanawan karyoku hatsudensho muke tokatsu kanri sochi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-10

    The collective control device is intended for efficiency improvement and safety assurance in daily maintenance and periodical checking works by collectively controlling maintenance and operation data in a power plant on a network. Fuji Electric has a schedule of starting operation in January 2001 the plant patrolling device, disaster preventing and monitoring device, comprehensive information management equipment, and collective LAN facilities to integrate the above items of equipment for Tachibana Bay Thermal Power Plant of Power Source Development Company. The plant patrolling device has 78 ITV cameras installed in the power plant ground, and displays image signals incorporated from the main devices and each site on CRTs installed in the operation center and offices via an image control device to achieve higher density in monitoring work. The collective control device has such functions to change over images sequentially according to previously registered changeover patterns, and display images in interlock with event occurrence such as burner ignition, in addition the function to select images arbitrarily. (NEDO)

  20. Bulk electrical conductivity as an indicator of spatial distribution of nitrogen and phosphorous at feedlots

    Science.gov (United States)

    Márquez Molina, J. J.; Sainato, C. M.; Urricariet, A. S.; Losinno, B. N.; Heredia, O. S.

    2014-12-01

    The increasing demands of producing beef for domestic and international consumption is leading to the development of feedlots in Argentina. Unfortunately, the great amount of manure produces leachate of nitrates and other ions which may affect groundwater quality. The objective of this paper was to identify the spatial distribution of bulk electrical conductivity (ECb) of non-saturated zone and its association with variability of nitrates and bioavailable phosphorous, water content, topography and electrical conductivity of saturated paste extract (EC). The analysis of the impact was done at two pens with different time of confinement of the animals (Pen1 and Pen 2, with 16 months and 7 years of animal occupation, respectively). The initial exploration phase was done by electrical resistivity tomography (ERT) and electromagnetic induction (EMI) surveys were subsequently performed at a subarea for studying the spatial distribution of ECb. A grid of soil sampling up to 1 m depth was done at the same subarea of the EMI survey. A geostatistical interpolation of data was performed in order to map ECb, water content, nitrogen, bioavailable phosphorous and EC. Anomalies of higher conductivity (between 6 and 10 times the background values) were found near the feedbunk and the water trough, being greater on soils with larger period of manure recharge. Water content, nitrogen of nitrates (N-NO3-), bioavailable phosphorous (Pavail.) and EC showed patterns of spatial distribution similar to ECb. These patterns are mainly associated with the runoff movement of water to the lower zones in the case of a steeper slope and the soil compaction as in the Pen 1. In the Pen 2, the patterns of spatial variability are similar for ECb and water content while anomalies of high ECb were found along an abandoned feedbunk. High values of N-NO3-, Pavail. and EC were found at this site. A longer period of manure recharge resulted in higher values of nitrogen and bioavailable phosphorous in

  1. Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

    Energy Technology Data Exchange (ETDEWEB)

    Bolotnikov,A.E.; , .; Camarda, G.S.; Cui, Y.; Hossain, A.; Yang, G.; Yao, H.W.; James, R.B.

    2009-10-19

    The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, <5 mm, the electric field-lines tend to bend away from the side surfaces (i.e., a focusing effect). In thick detectors, >1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field.

  2. FORECASTING ELECTRICITY PRICES IN DEREGULATED WHOLESALE SPOT ELECTRICITY MARKET - A REVIEW

    Directory of Open Access Journals (Sweden)

    Girish Godekere Panchakshara Murthy,

    2014-01-01

    Full Text Available In the new framework of competitive electricity markets, all power market participants need accurate price forecasting tools. Electricity price forecasts characterize significant information that can help captive power producer, independent power producer, power generation companies, power distribution companies or open access consumers in careful planning of their bidding strategies for maximizing their profits, benefits and utilities from long term, medium term and short term perspective. Short term spot electricity price forecasting techniques are either inspired from electrical engineering literature (i.e. load forecasting or from economics literature (i.e. game theory models and the time-series econometric models. In this study we investigate the emergence of spot electricity markets with particular emphasis on Indian electricity market which has never been done before and review selected finance and econometrics inspired literature and models for forecasting electricity spot prices in deregulated wholesale spot electricity markets.

  3. A traction control strategy with an efficiency model in a distributed driving electric vehicle.

    Science.gov (United States)

    Lin, Cheng; Cheng, Xingqun

    2014-01-01

    Both active safety and fuel economy are important issues for vehicles. This paper focuses on a traction control strategy with an efficiency model in a distributed driving electric vehicle. In emergency situation, a sliding mode control algorithm was employed to achieve antislip control through keeping the wheels' slip ratios below 20%. For general longitudinal driving cases, an efficiency model aiming at improving the fuel economy was built through an offline optimization stream within the two-dimensional design space composed of the acceleration pedal signal and the vehicle speed. The sliding mode control strategy for the joint roads and the efficiency model for the typical drive cycles were simulated. Simulation results show that the proposed driving control approach has the potential to apply to different road surfaces. It keeps the wheels' slip ratios within the stable zone and improves the fuel economy on the premise of tracking the driver's intention.

  4. Inspection of Wooden Poles in Electrical Power Distribution Networks in Artvin, Turkey

    Directory of Open Access Journals (Sweden)

    Engin Derya Gezer

    2015-01-01

    Full Text Available According to Trabzon Electricity Distribution Local Directorship’s statistical data, there are 208.000 utility poles in Trabzon, 180.000 utility poles in Rize, and 121.000 utility poles in Artvin. Every year, 17.000 new utility poles are placed in these three cities. The average lifetime of a treated-wood utility pole is typically 40 to 50 years. However, the average lifetime of a treated-wood utility pole in the Eastern Black Sea Region is only about 10–15 years. In this study, the suggestions for enhancing the service life of treated-wood utility poles in Artvin vicinity were listed by determining the deteriorations and degradations using both visual inspection and nondestructive test methods. The results showed that the most important factors affecting the service life of utility poles were the decay due to fungi, insects, inadequate impregnation, and the deep cracks and splits.

  5. Electrical performance of distribution insulators with chlorella vulgaris growth on its surface

    Directory of Open Access Journals (Sweden)

    H. E. Rojas

    2015-11-01

    Full Text Available This paper presents a study about electrical performance of ceramic and polymeric insulators bio-contaminated with alga Chlorella vulgaris. The performed tests involve ANSI 55-2 and ANSI 52-1 ceramic insulators and ANSI DS-15 polymeric insulators, all of them used in distribution systems of Colombia. Biological contamination of insulators is realized using a controlled environment chamber that adjusts the temperature, humidity and light radiation. The laboratory tests include measurements of flashover voltages and leakage currents and they were performed to determine how insulators are affected by biological contamination. After a series of laboratory tests, it was concluded that the presence of Chlorella vulgaris on the contaminated ceramic insulators reduces the wet flashover voltage up to 12% and increases their leakage currents up to 80%. On the other hand, for polymeric insulators the effect of algae growth on flashover voltages was not to strong, although the leakage currents increase up to 60%.

  6. Annoyance to Noise Produced by a Distributed Electric Propulsion High-Lift System

    Science.gov (United States)

    Rizzi, Stephen A.; Palumbo, Daniel L.; Rathsam, Jonathan; Christian, Andrew; Rafaelof, Menachem

    2017-01-01

    A psychoacoustic test was performed using simulated sounds from a distributed electric propulsion aircraft concept to help understand factors associated with human annoyance. A design space spanning the number of high-lift leading edge propellers and their relative operating speeds, inclusive of time varying effects associated with motor controller error and atmospheric turbulence, was considered. It was found that the mean annoyance response varies in a statistically significant manner with the number of propellers and with the inclusion of time varying effects, but does not differ significantly with the relative RPM between propellers. An annoyance model was developed, inclusive of confidence intervals, using the noise metrics of loudness, roughness, and tonality as predictors.

  7. An investigation into the development of consolidation of distributed generation within the wholesale electricity trading arrangements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    In this report the problems faced by distributed generators is explored under the New Electricity Trading Arrangements (NETA) in relation to the low price received for generation above contract requirement and the high price charged for under generation, and the lack of an alternative to the bilateral contract. The background to the study is traced, and the economics and history of consolidation, the NETA environment, development of imbalance prices, and the market for consolidation are outlined. An overview of consolidation in practice is presented, covering the generators and suppliers views, and specialist consolidators. The main options for development, and consolidation models are considered as well as net benefits, regulatory and commercial impediments to consolidation, and the potential impact of BETA.

  8. Comparative evaluation of distributed-collector solar thermal electric power plants

    Science.gov (United States)

    Fujita, T.; El Gabalawi, N.; Herrera, G. G.; Caputo, R. S.

    1978-01-01

    Distributed-collector solar thermal-electric power plants are compared by projecting power plant economics of selected systems to the 1990-2000 timeframe. The approach taken is to evaluate the performance of the selected systems under the same weather conditions. Capital and operational costs are estimated for each system. Energy costs are calculated for different plant sizes based on the plant performance and the corresponding capital and maintenance costs. Optimum systems are then determined as the systems with the minimum energy costs for a given load factor. The optimum system is comprised of the best combination of subsystems which give the minimum energy cost for every plant size. Sensitivity analysis is done around the optimum point for various plant parameters.

  9. Research on motor braking-based DYC strategy for distributed electric vehicle

    Science.gov (United States)

    Zhang, Jingming; Liao, Weijie; Chen, Lei; Cui, Shumei

    2017-08-01

    In order to bring into full play the advantages of motor braking and enhance the handling stability of distributed electric vehicle, a motor braking-based direct yaw moment control (DYC) strategy was proposed. This strategy could identify whether a vehicle has under-steered or overs-steered, to calculate the direct yaw moment required for vehicle steering correction by taking the corrected yaw velocity deviation and slip-angle deviation as control variables, and exert motor braking moment on the target wheels to perform correction in the manner of differential braking. For validation of the results, a combined simulation platform was set up finally to simulate the motor braking control strategy proposed. As shown by the results, the motor braking-based DYC strategy timely adjusted the motor braking moment and hydraulic braking moment on the target wheels, and corrected the steering deviation and sideslip of the vehicle in unstable state, improving the handling stability.

  10. A Traction Control Strategy with an Efficiency Model in a Distributed Driving Electric Vehicle

    Science.gov (United States)

    Lin, Cheng

    2014-01-01

    Both active safety and fuel economy are important issues for vehicles. This paper focuses on a traction control strategy with an efficiency model in a distributed driving electric vehicle. In emergency situation, a sliding mode control algorithm was employed to achieve antislip control through keeping the wheels' slip ratios below 20%. For general longitudinal driving cases, an efficiency model aiming at improving the fuel economy was built through an offline optimization stream within the two-dimensional design space composed of the acceleration pedal signal and the vehicle speed. The sliding mode control strategy for the joint roads and the efficiency model for the typical drive cycles were simulated. Simulation results show that the proposed driving control approach has the potential to apply to different road surfaces. It keeps the wheels' slip ratios within the stable zone and improves the fuel economy on the premise of tracking the driver's intention. PMID:25197697

  11. The Efficiency of the Regulation for Horizontal Mergers Among Electricity Distribution Operators in Norway

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter; Gammeltvedt, Thor Erik

    2015-01-01

    Merger analysis is usually drawing on concepts derived from competitive horizontal markets, such as market concentration, predatory foreclosure and economies of scale in marketing. In evaluating horizontal mergers among energy network operators, regulators must use different tools to evaluate...... the attractiveness of mergers. Norway is one country having implemented an ex ante regulation for mergers among electricity distribution operators (DSOs). We investigate whether the actual mergers of Norwegian DSOs in the period 1995-2004 can be rationalized as cost saving exercises or whether they should...... be interpreted in other ways. We use Data Envelopment Analysis (DEA) to estimate the potential cost savings from mergers ex ante, and we decompose the gains into gains from learning best practice and from improving economies of scale and scope. Moreover, we compare the sources of post merger performance...

  12. Review of Real-time Electricity Markets for Integrating Distributed Energy Resources and Demand Response

    DEFF Research Database (Denmark)

    Wang, Qi; Zhang, Chunyu; Ding, Yi

    2015-01-01

    The high penetration of both Distributed Energy Resources (DER) and Demand Response (DR) in modern power systems requires a sequence of advanced strategies and technologies for maintaining system reliability and flexibility. Real-time electricity markets (RTM) are the nondiscriminatory transaction...... platforms for providing necessary balancing services, where the market clearing (nodal or zonal prices depending on markets) is very close to real time operations of power systems. One of the primary functions of RTMs in modern power systems is establishing an efficient and effective mechanism for small DER...... and DR to participate in balancing market transactions, while handling their meteorological or intermittent characteristics, facilitating asset utilization, and stimulating their active responses. Consequently, RTMs are dedicated to maintaining the flexibility and reliability of power systems. This paper...

  13. Formation flying for electric sails in displaced orbits. Part II: Distributed coordinated control

    Science.gov (United States)

    Wang, Wei; Mengali, Giovanni; Quarta, Alessandro A.; Yuan, Jianping

    2017-09-01

    We analyze a cooperative control framework for electric sail formation flying around a heliocentric displaced orbit, aiming at observing the polar region of a celestial body. The chief spacecraft is assumed to move along an elliptic displaced orbit, while each deputy spacecraft adjusts its thrust vector (that is, both its sail attitude and characteristic acceleration) in order to track a prescribed relative trajectory. The relative motion of the electric sail formation system is formulated in the chief rotating frame, where the control inputs of each deputy are the relative sail attitude angles and the relative lightness number with respect to those of the chief. The information exchange among the spacecraft, characterized by the communication topology, is represented by a weighted graph. Two typical cases, according to whether the communication graph is directed or undirected, are discussed. For each case, a distributed coordinated control law is designed in such a way that each deputy not only tracks the chief state, but also makes full use of information from its neighbors, thus increasing the redundancy and robustness of the formation system in case of failure among the communication links. Illustrative examples show the effectiveness of the proposed approach.

  14. Health monitoring of electric power communication line using a distributed optical fiber sensor

    Science.gov (United States)

    Lu, Lidong; Liang, Yun; Li, Binglin; Guo, Jinghong; Zhang, Hao; Zhang, Xuping

    2014-11-01

    Optical fiber ground wire (OPGW) is used for both the earth line and communication line in electric power systems. It is important to find an effective to monitor the status of OPGW and diagnose some possible damages. Fault location of the optical fiber transmission line, lightning stroke location and early-warning of ice covering of OPGW are common tasks for OPGW health monitoring and maintenance. As to these issues, Brillouin optical time domain reflectometry (BOTDR) is employed for the health monitoring of OPGW. In experiment, a positive electrode with high pulsed current and a negative electrode are adopted to form a lightning impulse system with duration time of 200ms for simulation of the lightning stroke process, and a tensile force loading apparatus is also constructed to simulate the strain influence of the ice covering on the OPGW. Experimental results demonstrate that the BOTDR can sensitively locate the lightning stroke incidents with the quantity of electric discharging larger than 100C and the strain component has little interference on temperature monitoring as the fiber contained in the OPGW is generally free of strain, and in the ice covering condition the strain feature appears only when the extra tensile force on the OPGW is over 30kN. In addition, the vibration of OPGW does not disturb both the temperature and strain monitoring. As to further applications of distributed optical fiber sensors (DOFS) for the OPGW health monitoring, it is important to enhance its spatial resolution.

  15. Effect of artificial aging on polymeric surge arresters and polymer insulators for electricity distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Carlos A.; Coser, E. [Laboratorio de Materiais Polimericos, Departamento de Engenharia de Materiais, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil)], e-mail: ferreira.carlos@ufrgs.br; Angelini, Joceli M.G. [Departamento de Materiais Eletricos, CPqD, Campinas, SP (Brazil); Rossi, Jose A.D. [Materiais Alta Tensao, CPqD, Campinas, SP (Brazil); Martinez, Manuel L.B. [Departamento de Engenharia Eletrica, UNIFEI, Itajuba, MG (Brazil)

    2011-07-01

    A study was conducted to evaluate new and laboratory-aged samples of surge arresters and anchorage polymeric insulators, for 12 and 24 kV networks, which are used by the Rio Grande Energia (RGE). Power utility polymeric compounds were analyzed by Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TG), Dynamic-Mechanic Analysis (DMA), Fourier Transformed Infrared Spectroscopy (FTIR) and Scanning Electronic Microscopy (SEM) to verify changes in the insulator properties due to degradation occurred during the experiments. The analyses were carried out before and after 6 months of aging in laboratory devices (weather meter, 120 deg C, salt spray, immersion in water). After the aging experiments, high-voltage electrical tests were also conducted: a radio interference voltage test and, simultaneously, the total and the internal leakage currents were measured to verify the surface degradation of the polymeric material used in the housing. The impulse current test was applied with current values close to 5, 10 and 30 k A, in order to force an internal degradation. Results showed that only surface degradation is detected at the polymer. The main properties of the parts were not affected by the aging. It confirms that polymer insulator and surge arrester are appropriate for use in electricity distribution networks. (author)

  16. Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lacommare, Kristina S H; Stadler, Michael; Aki, Hirohisa; Firestone, Ryan; Lai, Judy; Marnay, Chris; Siddiqui, Afzal

    2008-05-15

    The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies.

  17. Wealth of the world's richest publicly traded companies per industry and per employee: Gamma, Log-normal and Pareto power-law as universal distributions?

    Science.gov (United States)

    Soriano-Hernández, P.; del Castillo-Mussot, M.; Campirán-Chávez, I.; Montemayor-Aldrete, J. A.

    2017-04-01

    Forbes Magazine published its list of leading or strongest publicly-traded two thousand companies in the world (G-2000) based on four independent metrics: sales or revenues, profits, assets and market value. Every one of these wealth metrics yields particular information on the corporate size or wealth size of each firm. The G-2000 cumulative probability wealth distribution per employee (per capita) for all four metrics exhibits a two-class structure: quasi-exponential in the lower part, and a Pareto power-law in the higher part. These two-class structure per capita distributions are qualitatively similar to income and wealth distributions in many countries of the world, but the fraction of firms per employee within the high-class Pareto is about 49% in sales per employee, and 33% after averaging on the four metrics, whereas in countries the fraction of rich agents in the Pareto zone is less than 10%. The quasi-exponential zone can be adjusted by Gamma or Log-normal distributions. On the other hand, Forbes classifies the G-2000 firms in 82 different industries or economic activities. Within each industry, the wealth distribution per employee also follows a two-class structure, but when the aggregate wealth of firms in each industry for the four metrics is divided by the total number of employees in that industry, then the 82 points of the aggregate wealth distribution by industry per employee can be well adjusted by quasi-exponential curves for the four metrics.

  18. Distributed Energy Systems Integration and Demand Optimization for Autonomous Operations and Electric Grid Transactions

    Energy Technology Data Exchange (ETDEWEB)

    Ghatikar, Girish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Greenlots, San Francisco, CA (United States); Mashayekh, Salman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Center for Energy and Innovation Technologies (Austria); Yin, Rongxin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Liu, Zhenhua [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-11-29

    Distributed power systems in the U.S. and globally are evolving to provide reliable and clean energy to consumers. In California, existing regulations require significant increases in renewable generation, as well as identification of customer-side distributed energy resources (DER) controls, communication technologies, and standards for interconnection with the electric grid systems. As DER deployment expands, customer-side DER control and optimization will be critical for system flexibility and demand response (DR) participation, which improves the economic viability of DER systems. Current DER systems integration and communication challenges include leveraging the existing DER and DR technology and systems infrastructure, and enabling optimized cost, energy and carbon choices for customers to deploy interoperable grid transactions and renewable energy systems at scale. Our paper presents a cost-effective solution to these challenges by exploring communication technologies and information models for DER system integration and interoperability. This system uses open standards and optimization models for resource planning based on dynamic-pricing notifications and autonomous operations within various domains of the smart grid energy system. It identifies architectures and customer engagement strategies in dynamic DR pricing transactions to generate feedback information models for load flexibility, load profiles, and participation schedules. The models are tested at a real site in California—Fort Hunter Liggett (FHL). Furthermore, our results for FHL show that the model fits within the existing and new DR business models and networked systems for transactive energy concepts. Integrated energy systems, communication networks, and modeling tools that coordinate supply-side networks and DER will enable electric grid system operators to use DER for grid transactions in an integrated system.

  19. Hybrid Systems of Distributed Generation with Renewable Sources: Modeling and Analysis of Their Operational Modes in Electric Power System

    Directory of Open Access Journals (Sweden)

    A. M. Gashimov

    2013-01-01

    Full Text Available The paper considers problems pertaining to modeling and simulation of operational hybrid system modes of the distributed generation comprising conventional sources – modular diesel generators, gas-turbine power units; and renewable sources – wind and solar power plants. Operational modes of the hybrid system have been investigated under conditions of electrical connection with electric power system and in case of its isolated operation. As a consequence

  20. Three Essays in Energy Economics and Industrial Organization, with Applications to Electricity and Distribution Networks

    Science.gov (United States)

    Dimitropoulos, Dimitrios

    Electricity industries are experiencing upward cost pressures in many parts of the world. Chapter 1 of this thesis studies the production technology of electricity distributors. Although production and cost functions are mathematical duals, practitioners typically estimate only one or the other. This chapter proposes an approach for joint estimation of production and costs. Combining such quantity and price data has the effect of adding statistical information without introducing additional parameters into the model. We define a GMM estimator that produces internally consistent parameter estimates for both the production function and the cost function. We consider a multi-output framework, and show how to account for the presence of certain types of simultaneity and measurement error. The methodology is applied to data on 73 Ontario distributors for the period 2002-2012. As expected, the joint model results in a substantial improvement in the precision of parameter estimates. Chapter 2 focuses on productivity trends in electricity distribution. We apply two methodologies for estimating productivity growth . an index based approach, and an econometric cost based approach . to our data on the 73 Ontario distributors for the period 2002 to 2012. The resulting productivity growth estimates are approximately 1% per year, suggesting a reversal of the positive estimates that have generally been reported in previous periods. We implement flexible semi-parametric variants to assess the robustness of these conclusions and discuss the use of such statistical analyses for calibrating productivity and relative efficiencies within a price-cap framework. In chapter 3, I turn to the historically important problem of vertical contractual relations. While the existing literature has established that resale price maintenance is sufficient to coordinate the distribution network of a manufacturer, this chapter asks whether such vertical restraints are necessary. Specifically, I study

  1. Why Do Electricity Policy and Competitive Markets Fail to Use Advanced PV Systems to Improve Distribution Power Quality?

    Directory of Open Access Journals (Sweden)

    Mark P. McHenry

    2016-01-01

    Full Text Available The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the network characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. We discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.

  2. Report made on behalf of the mixed parity commission in charge of the text proposal about the remaining dispositions to be discussed of the project of law relative to the electric and gas public utilities and to the electric and gas companies; Rapport fait au nom de la Commission mixte paritaire chargee de proposer un texte sur les dispositions restant en discussion du projet de loi relatif au service public de l'electricite et du gaz et aux entreprises electriques et gaziere

    Energy Technology Data Exchange (ETDEWEB)

    Lenoir, J.C.; Poniatowski, L

    2004-07-01

    This project of law aims to adapt the electricity and gas sector to the new economical context of opening of the energy markets to competition. It gives to energy companies the internal organization base necessary to warrant a high level of service and a transparent and non-discriminatory access of third parties to transport and distribution networks. These evolutions will allow Electricite de France (EdF) and Gaz de France (GdF) companies to compete on equal terms with their European competitors. It confirms first the prime role of public utility of both companies and then transposes the dispositions of the European directives relative to the organization of EdF and GdF integrated companies. It foresees the creation of two daughter companies for the management of energy transport activities. The project of law foresees also the change of the status of EdF and GdF companies and the reform of the retirement pensions of the personnel. This report presents, first, in a comparative table the articles adopted by the French house of commons and the changes adopted by the Senate. Then, a common text is proposed by the mixed parity commission for the articles that remained under discussion. (J.S.)

  3. Propulsion Electric Grid Simulator (PEGS) for Future Turboelectric Distributed Propulsion Aircraft

    Science.gov (United States)

    Choi, Benjamin B.; Morrison, Carlos; Dever, Timothy; Brown, Gerald V.

    2014-01-01

    NASA Glenn Research Center, in collaboration with the aerospace industry and academia, has begun the development of technology for a future hybrid-wing body electric airplane with a turboelectric distributed propulsion (TeDP) system. It is essential to design a subscale system to emulate the TeDP power grid, which would enable rapid analysis and demonstration of the proof-of-concept of the TeDP electrical system. This paper describes how small electrical machines with their controllers can emulate all the components in a TeDP power train. The whole system model in Matlab/Simulink was first developed and tested in simulation, and the simulation results showed that system dynamic characteristics could be implemented by using the closed-loop control of the electric motor drive systems. Then we designed a subscale experimental system to emulate the entire power system from the turbine engine to the propulsive fans. Firstly, we built a system to emulate a gas turbine engine driving a generator, consisting of two permanent magnet (PM) motors with brushless motor drives, coupled by a shaft. We programmed the first motor and its drive to mimic the speed-torque characteristic of the gas turbine engine, while the second motor and drive act as a generator and produce a torque load on the first motor. Secondly, we built another system of two PM motors and drives to emulate a motor driving a propulsive fan. We programmed the first motor and drive to emulate a wound-rotor synchronous motor. The propulsive fan was emulated by implementing fan maps and flight conditions into the fourth motor and drive, which produce a torque load on the driving motor. The stator of each PM motor is designed to travel axially to change the coupling between rotor and stator. This feature allows the PM motor to more closely emulate a wound-rotor synchronous machine. These techniques can convert the plain motor system into a unique TeDP power grid emulator that enables real-time simulation performance

  4. Smart Companies.

    Science.gov (United States)

    Galagan, Patricia A.

    1997-01-01

    Capturing and leveraging knowledge is an important new management trend that is as yet undefined. Some companies are accounting for their intellectual capital and applying it to the company balance sheets. (JOW)

  5. Electric Field and Potential Distribution in a 420 kV Novel Unibody Composite Cross-Arm

    DEFF Research Database (Denmark)

    Jahangiri, Tohid; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2015-01-01

    of shield wires. Due to a major difference between the novel cross-arm structure and traditional composite cross-arms, the electric field distribution in the uni-body composite cross-arm is of considerable interest. This paper presents and analyses the electric field distribution around and inside...... the hollow core uni-body cross-arm through which ground cable passes to connect the shield wires. Two different shed profiles are considered on the cross-arm and evaluated based on the guidelines of IEC 60815-3. The 2D geometry of pylon is modeled in ANSYS Finite Element Analysis package. The electric field...... and potential distribution along the pylon is graphically depicted and the effectiveness of assigned shed profiles in controlling the power frequency stresses are investigated in the areas with high field intensities....

  6. Performance of single wire earth return transformers with amorphous alloy core in a rural electric energy distribution system

    Directory of Open Access Journals (Sweden)

    Benedito Antonio Luciano

    2012-10-01

    Full Text Available In this paper are presented some considerations about the performance of single wire earth return amorphous alloy core transformers in comparison with conventional silicon steel sheets cores transformers used in rural electric energy distribution network. It has been recognized that amorphous metal core transformers improve electrical power distribution efficiency by reducing transformer core losses. This reduction is due to some electromagnetic properties of the amorphous alloys such as: high magnetic permeability, high resistivity, and low coercivity. Experimental results obtained with some single-phase, 60 Hz, 5 kVA amorphous core transformers installed in a rural area electric distribution system in Northern Brazil have been confirming their superior performance in comparison to identical nominal rated transformers built with conventional silicon steel cores, particularly with regard to the excitation power and to the no-load losses.

  7. Regional Differences in Demand for Coal as A Basis for Development of A Product Distribution Model for Mining Companies in the Individual Customers Segment

    Science.gov (United States)

    Magda, Roman; Bogacz, Paweł; Franik, Tadeusz; Celej, Maciej; Migza, Marcin

    2014-10-01

    The article presents a proposal of methodology based on the process of relationship marketing, serving to determine the level of demand for coal in the individual customer segment, as well as fuel distribution model for this customer group in Poland developed on the basis of this methodology. It also includes selected results of tests carried out using the proposed methods. These proposals have been defined on the basis of market capacity indicators, which can be determined for the district level based on data from the Polish Central Statistical Office. The study also included the use of linear programming, based on the cost of coal logistics, data concerning railway, road and storage infrastructure present on the Polish market and taking into account the legal aspects. The presented results may provide a basis for mining companies to develop a system of coal distribution management in the locations with the highest demand values.

  8. Infrared Scanning For Electrical Maintenance

    Science.gov (United States)

    Eisenbath, Steven E.

    1983-03-01

    Given the technological age that we have now entered, the purpose of this paper is to relate how infrared scanning can be used for an electrical preventative maintenance program. An infrared scanner is able to produce an image because objects give off infrared radiation in relationship to their temperature. Most electrical problems will show up as an increase in temperature, thereby making the infrared scanner a useful preventative maintenance tool. Because of the sensitivity of most of the scanners, .1 to .2 of a degree, virtually all electrical problems can be pinpointed long before they become a costly failure. One of the early uses of infrared scanning was to check the power company's electrical distribution system. Most of this was performed via aircraft or truck mounted scanning devices which necessitated its semi-permanent mounting. With the advent of small hand held infrared imagers, along with more portability of the larger systems, infrared scanning has gained more popularity in checking electrical distribution systems. But the distribution systems are now a scaled down model, mainly the in-plant electrical systems. By in-plant, I mean any distribution of electricity; once it leaves the power company's grid. This can be in a hospital, retail outlet, warehouse or manufacturing facility.

  9. DYNAMICS OF MAIN PROFITABILITY INDICATORS IN DISTRIBUTION OF FOOD AND AGRICULTURAL PRODUCTS OF THE COMPANY EL CASIO COM SRL-SLOBOZIA

    Directory of Open Access Journals (Sweden)

    Laurentiu MUNTEANU

    2013-01-01

    Full Text Available The return of distribution companies is related to the performance of activity based management, which can be expressed through a system of indicators reflecting their activity. This paper aims to analyse the company EL CASIO COM SRL Slobozia, active in the distribution field of food and agricultural products in Ialomita and Calarasi counties. We analysed the economic indicators between 1999-2009 from which resulted the main elements influencing the company’s revenue and profitability. The analysed period revealed that the break-even was achieved in 2003 with 5 employees, a revenue of 1899, 16 thousand lei whereas the expenses amounted 1732 thousand lei and labour productivity was set at 379, 8 thousand lei/ worker. The resulted trend after presenting and interpreting the exponential function Y=3,862·X10,5480866·X 21,239971is given based on the changes of income level (Y, from the factors of influence, represented by the amount of equity (x 1 and labour used (x 2. The multiple correlation ratios (rx 1x 2 = 0, 9505, confirm the influence intensity of the two factors upon the trends in revenue growth. As result we can see trends in revenue growth with amplification factors of influence

  10. Identification of Synchronous Generator Electric Parameters Connected to the Distribution Grid

    Directory of Open Access Journals (Sweden)

    Frolov M. Yu.

    2017-04-01

    Full Text Available According to modern trends, the power grids with distributed generation will have an open system architecture. It means that active consumers, owners of distributed power units, including mobile units, must have free access to the grid, like when using internet, so it is necessary to have plug and play technologies. Thanks to them, the system will be able to identify the unit type and the unit parameters. Therefore, the main aim of research, described in the paper, was to develop and research a new method of electric parameters identification of synchronous generator. The main feature of the proposed method is that parameter identification is performed while the generator to the grid, so it fits in the technological process of operation of the machine and does not influence on the connection time of the machine. For the implementation of the method, it is not necessary to create dangerous operation modes for the machine or to have additional expensive equipment and it can be used for salient pole machines and round rotor machines. The parameter identification accuracy can be achieved by more accurate account of electromechanical transient process, and making of overdetermined system with many more numbers of equations. Parameter identification will be made with each generator connection to the grid. Comparing data obtained from each connection, the middle values can be find by numerical method, and thus, each subsequent identification will accurate the machine parameters.

  11. IEEE 1547 and 2030 Standards for Distributed Energy Resources Interconnection and Interoperability with the Electricity Grid

    Energy Technology Data Exchange (ETDEWEB)

    Basso, T.

    2014-12-01

    Public-private partnerships have been a mainstay of the U.S. Department of Energy and the National Renewable Energy Laboratory (DOE/NREL) approach to research and development. These partnerships also include technology development that enables grid modernization and distributed energy resources (DER) advancement, especially renewable energy systems integration with the grid. Through DOE/NREL and industry support of Institute of Electrical and Electronics Engineers (IEEE) standards development, the IEEE 1547 series of standards has helped shape the way utilities and other businesses have worked together to realize increasing amounts of DER interconnected with the distribution grid. And more recently, the IEEE 2030 series of standards is helping to further realize greater implementation of communications and information technologies that provide interoperability solutions for enhanced integration of DER and loads with the grid. For these standards development partnerships, for approximately $1 of federal funding, industry partnering has contributed $5. In this report, the status update is presented for the American National Standards IEEE 1547 and IEEE 2030 series of standards. A short synopsis of the history of the 1547 standards is first presented, then the current status and future direction of the ongoing standards development activities are discussed.

  12. Mathematical model of the standalone electrical supply system with distributed photoelectric generation

    Directory of Open Access Journals (Sweden)

    Muravyev Dmitry I.

    2017-01-01

    Full Text Available A promising way to increase the technical and economic characteristics of standalone power supply systems is to incorporate renewable energy installations in their structure. Photoelectric generators based on distributed sources are optimal technologies for the use of renewable energy sources in 0.4 kV low-voltage power grid. The most common option is a hybrid system with photoelectric power stations (PES incorporated into the local network of the diesel power station (DPS. Photoelectric stations meet all environmental requirements and can make a significant contribution to the electrification of remote settlements, tourist and agricultural field. This paper deals with stabilization of voltage value and reduction of losses of electric energy depending on the parameters of elements of power supply systems of radial type (0,4 kV with an installed capacity of up to 100 kW. The research has been conducted by simulating the operating modes of hybrid power systems of various configurations. To analyze the joint work of a photoelectric station with a diesel power station, a mathematical model is created in the Simulink (SimPowerSystems application of the MatLab R2016b program. Most of the known works do not show the issues of quality and power losses in the standalone power supply system with photoelectric distributed generation. [5,6,7,9,10].

  13. Decision from the Commission of Electricity Regulation (CRE) dated from June 27, 2002 about a disagreement between Semmaris company and Electricite de France, as manager of the public power distribution grid, relative to the conditions of consideration of the multiplicity of delivery points in the contractual system of access to the grid; Decision de la Commission de Regulation de l'Electricite (CRE) en date du 27 juin 2002 sur un different, qui oppose la societe Semmaris a Electricite de France, en tant que gestionnaire du reseau public de distribution d'electricite, relatif aux conditions de prise en compte de la multiplicite des points de livraison dans le dispositif contractuel d'acces au reseau electrique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-06-01

    This document presents the analysis made by the French commission of electricity regulation (CRE) about a disagreement between Semmaris company (Rungis, France) and Electricite de France (EdF) concerning the request by Semmaris for the subscription of a single contract of access to the grid for its 18 supply points instead of 9 contracts as proposed by EdF after acceptation of a partial regrouping of some supply points under the same contracts. After examination of the hearings, the CRE requested EdF to establish non-discriminatory objective criteria for the regrouping of different delivery points in a same contract before making a new examination of the disagreement between Semmaris and EdF. (J.S.)

  14. Global tidal variations, regional distribution of ventilation, and the regional onset of filling determined by electrical impedance tomography: reproducibility.

    Science.gov (United States)

    Caruana, L R; Barnett, A G; Tronstad, O; Paratz, J D; Chang, A T; Fraser, J F

    2017-03-01

    The reproducibility of the regional distribution of ventilation and the timing of onset of regional filling as measured by electrical impedance tomography lacks evidence. This study investigated whether electrical impedance tomography measurements in healthy males were reproducible when electrodes were replaced between measurements. Part 1: Recordings of five volunteers lying supine were made using electrical impedance tomography and a pneumotachometer. Measurements were repeated at least three hours later. Skin marking ensured accurate replacement of electrodes. No stabilisation period was allowed. Part 2: Electrical impedance tomography recordings of ten volunteers; a 15 minute stabilisation period, extra skin markings, and time-averaging were incorporated to improve the reproducibility. Reproducibility was determined using the Bland-Altman method. To judge the transferability of the limits of agreement, a Pearson correlation was used for electrical impedance tomography tidal variation and tidal volume. Tidal variation was judged to be reproducible due to the significant correlation between tidal variation and tidal volume (r2 = 0.93). The ventilation distribution was not reproducible. A stabilisation period, extra skin markings and time-averaging did not improve the outcome. The timing of regional onset of filling was reproducible and could prove clinically valuable. The reproducibility of the tidal variation indicates that non-reproducibility of the ventilation distribution was probably a biological difference and not measurement error. Other causes of variability such as electrode placement variability or lack of stabilisation when accounted for did not improve the reproducibility of the ventilation distribution.

  15. Plug-in hybrid electric vehicles as a source of distributed frequency regulation

    Science.gov (United States)

    Mullen, Sara Kathryn

    The movement to transform the North American power grid into a smart grid may be accomplished by expanding integrated sensing, communications, and control technologies to include every part of the grid to the point of end-use. Plug-in hybrid electric vehicles (PHEV) provide an opportunity for small-scale distributed storage while they are plugged-in. With large numbers of PHEV and the communications and sensing associated with the smart grid, PHEV could provide ancillary services for the grid. Frequency regulation is an ideal service for PHEV because the duration of supply is short (order of minutes) and it is the highest priced ancillary service on the market offering greater financial returns for vehicle owners. Using Simulink a power system simulator modeling the IEEE 14 Bus System was combined with a model of PHEV charging and the controllers which facilitate vehicle-to-grid (V2G) regulation supply. The system includes a V2G controller for each vehicle which makes regulation supply decisions based on battery state, user preferences, and the recommended level of supply. A PHEV coordinator controller located higher in the system has access to reliable frequency measurements and can determine a suitable local automatic generation control (AGC) raise/lower signal for participating vehicles. A first step implementation of the V2G supply system where battery charging is modulated to provide regulation was developed. The system was simulated following a step change in loading using three scenarios: (1) Central generating units provide frequency regulation, (2) PHEV contribute to primary regulation analogous to generator speed governor control, and (3) PHEV contribute to primary and secondary regulation using an additional integral term in the PHEV control signal. In both cases the additional regulation provided by PHEV reduced the area control error (ACE) compared to the base case. Unique contributions resulting from this work include: (1) Studied PHEV energy systems

  16. Computational intelligence applied to the logistics of electric energy distribution network maintenance teams; Inteligencia computacional aplicada a logistica de equipes de manutencao de redes de distribuicao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Bobel, Edson [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)]. E-mails: edson.bobel@copel.com; Lopes, Heitor Silverio [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba (Brazil)]. E-mail: hslopes@utfpr.edu.br

    2007-10-15

    One of the problems that an Electric Energy Distribution Company faces is the maintenance of its distribution network. This study focuses on the problem of allocating emergency maintenance teams so that costs related to the energy outage as well as the cost of the teams themselves are minimized. This study includes a geographic area of 108 counties in the State of Parana, Brazil, and uses information related to: interruptions history in high voltage switches, list of locations able to allocate emergency maintenance teams and list of switches that were actually served by the maintenance teams during the year 2002. With this information and the list of locations with emergency maintenance teams, an estimate of the situation is made and the costs are calculated for the year 2002. With this in hand, the problem was solved using two methods: p-medians and genetic algorithms, in which the potential gains of 13.37% and 12.64% were obtained, respectively, as compared to the costs in 2002, for the same geographic area. Finally, a projection was made for the potential decrease of costs for the Electric Distribution Company regarding the total area of Parana State, as well as an estimate of financial profits for the State Government. (author)

  17. Design and Analysis of Electrical Distribution Networks and Balancing Markets in the UK: A New Framework with Applications

    Directory of Open Access Journals (Sweden)

    Vijayanarasimha Hindupur Pakka

    2016-02-01

    Full Text Available We present a framework for the design and simulation of electrical distribution systems and short term electricity markets specific to the UK. The modelling comprises packages relating to the technical and economic features of the electrical grid. The first package models the medium/low distribution networks with elements such as transformers, voltage regulators, distributed generators, composite loads, distribution lines and cables. This model forms the basis for elementary analysis such as load flow and short circuit calculations and also enables the investigation of effects of integrating distributed resources, voltage regulation, resource scheduling and the like. The second part of the modelling exercise relates to the UK short term electricity market with specific features such as balancing mechanism and bid-offer strategies. The framework is used for investigating methods of voltage regulation using multiple control technologies, to demonstrate the effects of high penetration of wind power on balancing prices and finally use these prices towards achieving demand response through aggregated prosumers.

  18. The strategic ''pull'' and operational ''push'' of total quality management in UK regional electricity service companies

    Energy Technology Data Exchange (ETDEWEB)

    McAdam, R.; McLean, J.; Henderson, J.

    2003-04-30

    The aim of this paper is to evaluate whether the UK regional electricity companies (RECs) has used total quality management (TQM) as a ''push'' or as a ''pull'' change methodology. ''Push'' is the operational improvement role of TQM; ''pull'' is the strategic or direction giving, improvement role of TQM. Following the onset of privatisation in 1990 there has been evidence of the RECs adopting TQM in both ''push'' and ''pull'' methodologies with varying degrees of success. An evaluation of the change processes involved will enable improved change models to be developed leading to increased business effectiveness in this 30 billion pounds sterling industry. Other possible benefits include the possible generalisations to other utilities such as water, roads, gas and telecoms. The research methodology includes a comparative case study analysis of five RECs, which have used TQM as their overarching approach to change. One of the cases is analysed to a more in-depth level based on the multiple case findings. The findings indicate that the ''push-pull'' analysis enables the full range of TQM activities to be evaluated in the RECs studied. Overall, there is a need to have a balanced portfolio of operational or ''push''-based TQM activity that is driven by strategic or ''pull'' based TQM planning and activity. (author)

  19. Intake fraction assessment of the air pollutant exposure implications of a shift toward distributed electricity generation

    Science.gov (United States)

    Heath, Garvin A.; Granvold, Patrick W.; Hoats, Abigail S.; W Nazaroff, William

    Small-scale, distributed electricity generation (DG) technologies have been promoted for their many benefits as compared to the traditional paradigm of large, centralized power plants. To evaluate the implications for human inhalation exposure resulting from a shift toward DG, we combined Gaussian plume modeling and a GIS-based inhalation exposure assessment of existing and hypothetical power-generation facilities in California. Twenty-five existing central stations (CSs) were analyzed and compared with hypothetical DG technologies deployed in the downtown areas of the 11 most populous cities in California. The intake fraction (iF) for primary pollutants was computed for populations living within 100 km of each source, using meteorological conditions typical of the long-term observational record and population, lifetime-average breathing rates. The iF (a dimensionless term representing the proportion of pollutant mass emitted by a source that is eventually inhaled) concisely expresses the source-to-intake relationship, is independent of the emissions characteristics of the plants assessed, and normalizes for the large scale differences between the two paradigms of electricity generation. The median iF for nonreactive primary pollutants emitted from the 25 CSs is 0.8 per million compared to 16 per million for the 11 DG units. The difference is partly attributable to the closer proximity of DG sources to densely populated areas as compared to typical CS facilities. In addition, the short stacks of DG sources emphasize near-source population exposure more than traditional CSs, and increase exposures during periods of low wind speed, low mixing height and stable atmospheric conditions. Strategies that could reduce the potential increase in air pollutant intake from DG include maximally utilizing waste heat in combined heat and power operations, increasing the release height of DG effluents and deploying DG technologies that do not emit air pollutants.

  20. Optimizing the Distribution System of Fast Moving Consumer Goods Company Using Sweeping Methods with Discrete Event Simulation Approach

    Directory of Open Access Journals (Sweden)

    Rahmawan D. Arry

    2017-01-01

    Full Text Available FMCG is considered as one of the industry with the highest competition in the world. To win this industry, customer satisfaction becomes the main thing. In this paper, authors will simulate a system of distribution of goods from PT X TBK which has 3 categories, namely M1 (biscuit, M2 (powder and M3 (liquid. The distribution system has a problem on time delivery of goods which have a wide variety of obstacles, mainly on routing. There are 8 trucks with different routes and different utilization. There's trucks with over hour work and trucks with long idle time. The routing also causes problem for unused truck weight and volume capacity, where cost could possibly be reduced. Through Discrete event simulation and sweeping method, authors try to solve the problem by modelling the existing system and then find the solution to improve the distribution system and reaching the model objective.