WorldWideScience

Sample records for electrical stunning voltages

  1. The effects of alternative electrical and mechanical stunning methods on hemorrhaging and meat quality of broiler breast and thigh muscles

    NARCIS (Netherlands)

    Hillebrand, S.J.W.; Lambooij, E.; Veerkamp, C.H.

    1996-01-01

    Five trials were conducted to determine the effects of various alternative stunning and restraining methods on the quality of chicken broiler meat. The stunning methods used were electrical whole-body and head-only stunning with different voltages (25 vs 100 V) and frequencies (50 vs 200 Hz), and

  2. Impact of alternative electrical stunning parameters on the ability of broilers to recover consciousness and meat quality

    Science.gov (United States)

    Broilers in the United States are typically electrically stunned using low voltage-high frequency (12-38V, =400Hz) DC or AC water bath stunners. In the European Union, however, broilers are required to be electrocuted using high voltage-low frequency (50-150V, 50-350Hz) AC. Low voltage stunned broil...

  3. Electrical stunning, hot boning, and quality of chicken breast meat.

    Science.gov (United States)

    Contreras, C C; Beraquet, N J

    2001-04-01

    The first experiment was conducted to determine the effects of varying voltage, 20, 40, 80, and 100 V at 60 Hz, on stunning efficiency, blood loss, and carcass defects. In the second experiment, the same parameters were evaluated to determine the effects of varying frequency, 60, 200, 350, 500, and 1,000 Hz at 40 V. A control group for both experiments was not stunned. At 40V, 30 to 50 mA, 90% of the birds were unconscious, as shown by no response to comb piercing, and blood loss was maximized (55.3%). When varying the stunning frequency, maximum blood loss (73.1%), 90% of the birds were unconscious, and minimum carcass defects were observed at 1,000 Hz, 40 V. In the third experiment, birds were stunned at 40 V, 1,000 Hz and deboned immediately after defeathering (hot boning) and chilled or deboned after passing through all stages of a commercial abattoir operation (conventional boning). Control lots were unstunned and followed normal abattoir stages. Average shear value was significantly lower for stunned compared to unstunned birds (6.0 vs. 7.1 kg/g), although tenderness scores, as measured by a trained panel, were not significantly different (6.6 for stunned birds vs. 6.1 for unstunned). Scores for juiciness were also not significantly different (5.5 for stunned vs. 5.8 for unstunned). Average shear value was also significantly lower for conventionally boned birds (5.2 kg/g) than for hot boned birds (7.9 kg/g). Sensory analysis confirmed the shear value results. Conventionally boned breasts had an average tenderness score of 7.4 vs. an average of 5.3 for hot boned breast. No statistical differences were observed with respect to juiciness, although a score of 6.2 was observed for conventionally boned breast meat vs. a score of 5.1 for hot boned breast meat.

  4. Bleedout efficiency, carcass damage, and rigor mortis development following electrical stunning or carbon dioxide stunning on a shackle line.

    Science.gov (United States)

    Kang, I S; Sams, A R

    1999-01-01

    In Experiment 1, 400 male broilers were stunned using a gradient of 40 to 60% CO2 over a period of 25 s or a 1% brine solution that was electrically charged (35 mA) for 7 s. Blood loss during bleeding was measured in 30-s intervals for a total of 120 s. After conventional processing and chilling, carcass damage was subjectively evaluated. Results indicated that the birds stunned with electricity bled faster than the CO2-stunned birds until 60 s. However, the cumulative blood loss was not different after 90 s. Carcass damage evaluation indicated that birds stunned with CO2 had a significantly lower percentage of broken clavicles, and had fewer hemorrhages on the surface of the Pectoralis. However, there was no difference between the two stunning methods in the frequency of damage at the shoulder. In Experiment 2, 256 broilers were stunned using the same conditions as in Experiment 1. Measurements of pH, R-value, sarcomere length (SL), and fragmentation index (FI) were evaluated from the left breast fillets harvested at 0, 1, 2, and 6 h postmortem. Shear values (SV) were determined using the right fillets harvested at the same four postmortem times and aged on ice until 24 h. No significant difference in breast muscle pH value was observed at 0, 2, and 6 h postmortem. However, CO2-stunned fillets had significantly higher pH values than the ES fillets at 1 h postmortem. Carbon dioxide produced greater R values than electricity at 2 and 6 h. Sarcomere length, FI, and SV were not significantly different at any time tested. These data suggest that CO2 stunning reduced carcass damage but did not reduce the need for aging before deboning when compared to the electrical stunning method used.

  5. Bleeding Efficiency, Microbiological Quality and Oxidative Stability of Meat from Goats Subjected to Slaughter without Stunning in Comparison with Different Methods of Pre-Slaughter Electrical Stunning.

    Science.gov (United States)

    Sabow, Azad Behnan; Zulkifli, Idrus; Goh, Yong Meng; Ab Kadir, Mohd Zainal Abidin; Kaka, Ubedullah; Imlan, Jurhamid Columbres; Abubakar, Ahmed Abubakar; Adeyemi, Kazeem Dauda; Sazili, Awis Qurni

    2016-01-01

    The influence of pre-slaughter electrical stunning techniques and slaughter without stunning on bleeding efficiency and shelf life of chevon during a 14 d postmortem aging were assessed. Thirty two Boer crossbred bucks were randomly assigned to four slaughtering techniques viz slaughter without stunning (SWS), low frequency head-only electrical stunning (LFHO; 1 A for 3 s at a frequency of 50 Hz), low frequency head-to-back electrical stunning (LFHB; 1 A for 3 s at a frequency of 50 Hz) and high frequency head-to-back electrical stunning (HFHB; 1 A for 3 s at a frequency of 850 Hz). The SWS, LFHO and HFHB goats had higher (pmeat had higher (pmeat compared to those from SWS, LFHO and HFHB after 3 d postmortem. Results indicate that the low bleed-out in LFHB lowered the lipid oxidative stability and microbiological quality of chevon during aging.

  6. Rigor mortis development in turkey breast muscle and the effect of electrical stunning.

    Science.gov (United States)

    Alvarado, C Z; Sams, A R

    2000-11-01

    Rigor mortis development in turkey breast muscle and the effect of electrical stunning on this process are not well characterized. Some electrical stunning procedures have been known to inhibit postmortem (PM) biochemical reactions, thereby delaying the onset of rigor mortis in broilers. Therefore, this study was designed to characterize rigor mortis development in stunned and unstunned turkeys. A total of 154 turkey toms in two trials were conventionally processed at 20 to 22 wk of age. Turkeys were either stunned with a pulsed direct current (500 Hz, 50% duty cycle) at 35 mA (40 V) in a saline bath for 12 seconds or left unstunned as controls. At 15 min and 1, 2, 4, 8, 12, and 24 h PM, pectoralis samples were collected to determine pH, R-value, L* value, sarcomere length, and shear value. In Trial 1, the samples obtained for pH, R-value, and sarcomere length were divided into surface and interior samples. There were no significant differences between the surface and interior samples among any parameters measured. Muscle pH significantly decreased over time in stunned and unstunned birds through 2 h PM. The R-values increased to 8 h PM in unstunned birds and 24 h PM in stunned birds. The L* values increased over time, with no significant differences after 1 h PM for the controls and 2 h PM for the stunned birds. Sarcomere length increased through 2 h PM in the controls and 12 h PM in the stunned fillets. Cooked meat shear values decreased through the 1 h PM deboning time in the control fillets and 2 h PM in the stunned fillets. These results suggest that stunning delayed the development of rigor mortis through 2 h PM, but had no significant effect on the measured parameters at later time points, and that deboning turkey breasts at 2 h PM or later will not significantly impair meat tenderness.

  7. Feather retention force in broilers ante-, peri-, and post-mortem as influenced by electrical and carbon dioxide stunning.

    Science.gov (United States)

    Buhr, R J; Cason, J A; Rowland, G N

    1997-11-01

    Stunning and slaughter trials were conducted to evaluate the influence of stunning method (electrical 50 V alternating current, CO2 gas: 0 to 40% for 90 s or 40 to 60% for 30 s) on feather retention force (FRF) in commercial broilers. Feathers from the pectoral, sternal, and femoral feather tracts were sampled with a force gauge before stunning (ante-mortem) and contralaterally either after stunning (peri-mortem from 0.5 to 4 min) or after stunning and bleeding (post-mortem from 2 to 6 min). Prior to stunning, ante-mortem FRF values varied among assigned stunning methods only for the pectoral (7%) feather tract. After stunning, peri-mortem FRF values were higher only for the sternal tract (11% for 40 to 60% CO2 for 30 s); whereas after stunning and bleeding, post-mortem FRF values were lower than ante- or peri-mortem only for the sternal tract (10% lower for 40 to 60% CO2 for 30 s). Peri- and post-mortem FRF values did not differ among stunning methods for the pectoral and femoral feather tracts. Small changes in FRF values occurred from ante-mortem to peri-mortem (-1 to +12%), and from ante-mortem to post-mortem (-2 to +8%) across stunning methods. A significant increase was determined for only the pectoral tract (7%) from ante- to peri-mortem across stunning methods. Electrically stunned broilers that were not bled gained weight in excess of the 36 feathers removed (0.16%), apparently due to body surface water pickup during the brine-stunning process, whereas CO2-stunned broilers lost weight due to excretion of cloacal contents (-0.31 to -0.98%). The change in body weight among stunning methods was significant (P defeathering efficiency may not differ after scalding.

  8. Bleeding Efficiency, Microbiological Quality and Oxidative Stability of Meat from Goats Subjected to Slaughter without Stunning in Comparison with Different Methods of Pre-Slaughter Electrical Stunning

    Science.gov (United States)

    Sabow, Azad Behnan; Zulkifli, Idrus; Goh, Yong Meng; Ab Kadir, Mohd Zainal Abidin; Kaka, Ubedullah; Imlan, Jurhamid Columbres; Abubakar, Ahmed Abubakar; Adeyemi, Kazeem Dauda; Sazili, Awis Qurni

    2016-01-01

    The influence of pre-slaughter electrical stunning techniques and slaughter without stunning on bleeding efficiency and shelf life of chevon during a 14 d postmortem aging were assessed. Thirty two Boer crossbred bucks were randomly assigned to four slaughtering techniques viz slaughter without stunning (SWS), low frequency head-only electrical stunning (LFHO; 1 A for 3 s at a frequency of 50 Hz), low frequency head-to-back electrical stunning (LFHB; 1 A for 3 s at a frequency of 50 Hz) and high frequency head-to-back electrical stunning (HFHB; 1 A for 3 s at a frequency of 850 Hz). The SWS, LFHO and HFHB goats had higher (p<0.05) blood loss and lower residual hemoglobin in muscle compared to LFHB. The LFHB meat had higher (p<0.05) TBARS value than other treatments on d 7 and 14 d postmortem. Slaughtering methods had no effect on protein oxidation. Higher bacterial counts were observed in LFHB meat compared to those from SWS, LFHO and HFHB after 3 d postmortem. Results indicate that the low bleed-out in LFHB lowered the lipid oxidative stability and microbiological quality of chevon during aging. PMID:27035716

  9. Electrical and percussive stunning of the common carp (Cyprinus carpio L.): Neurological and behavioural assessment

    NARCIS (Netherlands)

    Lambooij, E.; Pilarczyk, M.; Bialowas, H.; Boogaart, van den J.G.M.; Vis, van de J.W.

    2007-01-01

    The overall objective of the study was to evaluate electrical and percussive stunning methods under laboratory conditions in common carps. The electrical current needed to induce a general epileptiform insult was assessed in 13 carps. The insult was obtained by delivering a current of 0.24 ± 0.03 A

  10. Cone restraining and head-only electrical stunning in broilers: Effects on physiological responses and meat quality

    NARCIS (Netherlands)

    Lambooij, E.; Reimert, H.G.M.; Verhoeven, M.T.W.; Hindle, V.A.

    2014-01-01

    Two experiments were conducted to evaluate a new electrical stunning system for broilers. The objective of the first experiment was to evaluate the behavioral, neural, and physiological responses of 27 broilers after head-only electrical stunning while their bodies were restrained in cone-shaped

  11. Electrical stunning of farmed Atlantic cod Gadus morhua L.: a comparison of an industrial and experimental method

    NARCIS (Netherlands)

    Digre, H.; Erikson, U.; Misimi, E.; Lambooij, E.; Vis, van de J.W.

    2010-01-01

    An industrial and experimental electrical method for stunning farmed Atlantic cod in air and seawater (SW), respectively, were compared. The impacts of sedation with AQUI-S™ and exercise to exhaustion before electrical stunning were also assessed to monitor the possible depletion of rested muscle

  12. Why poultry should be stunned at slaughter and the welfare advantages/challenges of electrical and gas stunning

    Science.gov (United States)

    Poultry are stunned immediately prior to slaughter to facilitate automated processing, to suppress the subsequent death struggle and thereby minimize carcass damage and down grades, and to render the bird unconscious and incapable to perceive pain. A stunning method should be considered ethical if ...

  13. Efficiency of Electrical Stunning by Electronarcosis: Current Situation and Perspective of Improvement in a Medium-Size Processing Plant

    Directory of Open Access Journals (Sweden)

    RL Barbosa

    Full Text Available ABSTRACT The objective of this study was to evaluate the efficiency of electrical stunning by electronarcosis in a medium-size poultry processing plant located in southern Brazil. The current measurement of this type of stunning is presented, and then improvements to this method are proposed. Data were collected for 90 days. A quality indicator was proposed: the Stunning Severity Index (SSI, which includes elements of Statistical Process Control (SPC using a p-chart (proportion chart and measures. This index comprises the variables "wing-flapping," "arched head," and "rhythmic breathing." Using the proposed index, 5% of the birds, on average, presented inefficient stunning symptoms.

  14. Effects of electrical water bath stunning current frequencies on the spontaneous electroencephalogram and somatosensory evoked potentials in hens.

    Science.gov (United States)

    Raj, A B M; O'Callaghan, M

    2004-04-01

    1. The effectiveness of water bath electrical stunning of chickens with a constant root mean square (rms) current of 100 mA per bird delivered for 3 s using 100, 200, 400, 800 and 1500 Hz sine wave alternating current (AC) was investigated in layer hens. The quantitative changes occurring in the electroencephalogram (EEG) and somatosensory evoked potentials (SEPs) were used to determine the effectiveness of stunning. The changes occurring in the EEG were evaluated using Fast Fourier Transformations (FFT) and the SEPs were averaged to determine whether they were present or abolished. 2. The results of FFT indicated that stunning of chickens with a constant rms current of 100 mA per bird using 100 or 200 Hz induced epileptiform activity in all the hens, immediately followed by a reduction in the total (2 to 30 Hz) and relative (13 to 30 Hz) power contents in the EEG frequency bands indicative of unconsciousness and insensibility. The SEPs were abolished in the majority of hens stunned with 100 Hz and all the hens stunned with 200 Hz. 3. By contrast, stunning using 400, 800 or 1500 Hz failed to induce epileptiform activity in all the birds, the total and relative power contents in the EEG frequency bands showed a substantial increase, rather than reduction, and the SEPs were also retained in the majority of chickens. It is therefore suggested that stunning using these frequencies failed to stun them satisfactorily. In these birds, occurrence of a painful arousal, rather than unconsciousness, could not be ruled out. 4. It is therefore suggested that water bath electrical stunning of chickens with a minimum rms current of 100 mA per bird delivered using 100 or 200 Hz would be adequate to ensure bird welfare under commercial conditions, provided both the carotid arteries in the neck are severed at slaughter. On humanitarian and bird welfare grounds, a rms current of greater than 100 mA per bird should be applied whilst using frequencies of 400 Hz or more of sine wave AC

  15. Electrical stunning and exsanguination decrease the extracellular volume in the broiler brain as studied with brain impedance recordings

    NARCIS (Netherlands)

    Savenije, B; Lambooij, E; Pieterse, C; Korf, J

    Electrical stunning in the process of slaughtering poultry is used to induce unconsciousness and immobilize the animal for easier processing. Unconsciousness is a function of brain damage. Brain damage has been studied with brain impedance recordings under ischemic conditions. This experiment

  16. Head-only electrical stunning and bleeding of African catfish (Clarias gariepinus): assessment of loss of consciousness

    NARCIS (Netherlands)

    Lambooij, E.; Kloosterboer, R.J.; Gerritzen, M.A.; Vis, van de J.W.

    2004-01-01

    The objective was to evaluate the welfare implications of electrical stunning prior to gill-cutting of farmed African catfish as an alternative to live chilling in combination with gutting. Electroencephalogram (EEG) and electrocardiogram (ECG) recordings, in combination with observation of

  17. Assessing effectiveness of electrical stunning and chillingin ice water of farmed yellowtail kingfish, common sole and pike-perch

    NARCIS (Netherlands)

    Llonch, P.; Lambooij, E.; Reimert, H.G.M.; Vis, van de J.W.

    2012-01-01

    Animals should be rendered unconscious before slaughter in order to avoid suffering or pain. The objective of this study was to evaluate an electrical stunning after dewatering to induce instantaneous unconsciousness and insensibility in yellowtail kingfish (Seriola lalandi), common sole (Solea

  18. Conditions for instant electrical stunning of farmed Atlantic cod after de-watering, maintenance of unconsciousness, effects of stress, and fillet quality — A comparison with AQUI-S™

    NARCIS (Netherlands)

    Erikson, U.; Lambooij, E.; Digre, H.; Reimert, H.G.M.; Bondø, M.; Vis, van de H.

    2012-01-01

    Electrical stunning of farmed Atlantic cod is a method used to render the fish unconscious before further processing. However, evaluations of the stunning method at plants have shown that the electrical parameters need to be optimized to achieve instant stunning and prolonged duration of

  19. Stunning poultry prior to slaughter and the welfare advantages/challenges of electrical and controlled atmosphere stunning pp. 90-98.

    Science.gov (United States)

    Poultry are stunned immediately prior to slaughter to render them unconscious and incapable of perceiving pain, to facilitate automated processing (up to 180 birds/min), and to minimize the occurrence of the death struggle and thereby minimize carcass damage and down grades. A stunning method for s...

  20. Cardiac effects of electrical stun guns: does position of barbs contact make a difference?

    Science.gov (United States)

    Lakkireddy, Dhanunjaya; Wallick, Donald; Verma, Atul; Ryschon, Kay; Kowalewski, William; Wazni, Oussama; Butany, Jagdish; Martin, David; Tchou, Patrick J

    2008-04-01

    The use of electrical stun guns has been rising among law enforcement authorities for subduing violent subjects. Multiple reports have raised concerns over their safety. The cardiovascular safety profile of these devices in relationship to the position of delivery on the torso has not been well studied. We tested 13 adult pigs using a custom device built to deliver neuromuscular incapacitating (NMI) discharge of increasing intensity that matched the waveform of a commercially available stun gun (TASER(R) X-26, TASER International, Scottsdale, AZ, USA). Discharges with increasing multiples of output capacitances were applied in a step-up and step-down fashion, using two-tethered barbs at five locations: (1) Sternal notch to cardiac apex (position-1), (2) sternal notch to supraumbilical area (position-2), (3) sternal notch to infraumbilical area (position-3), (4) side to side on the chest (position-4), and (5) upper to lower mid-posterior torso (position-5). Endpoints included determination of maximum safe multiple (MaxSM), ventricular fibrillation threshold (VFT), and minimum ventricular fibrillation induction multiple (MinVFIM). Standard TASER discharges repeated three times did not cause ventricular fibrillation (VF) at any of the five locations. When the barbs were applied in the axis of the heart (position-1), MaxSM and MinVFIM were significantly lower than when applied away from the heart, on the dorsum (position-5) (4.31 +/- 1.11 vs 40.77 +/- 9.54, P< 0.001 and 8.31 +/- 2.69 vs 50.77 +/- 9.54, P< 0.001, respectively). The values of these endpoints at position-2, position-3, and position-4 were progressively higher and ranged in between those of position-1 and position-5. Presence of ventricular capture at a 2:1 ratio to the delivered TASER impulses correlated with induction of VF. No significant metabolic changes were seen after standard NMI TASER discharge. There was no evidence of myocardial damage based on serum cardiac markers, electrocardiography

  1. Effect of electrical stunning frequency on meat quality, plasma parameters, and protein solubility of broilers.

    Science.gov (United States)

    Huang, J C; Yang, J; Zhang, B H; Huang, M; Chen, K J; Xu, X L; Zhou, G H

    2017-08-01

    This study was designed to compare the effects of different stunning frequencies of pulsed direct current on meat quality of broilers. This was achieved by investigating plasma parameters, blood loss, carcass damage, meat water-holding capacity, meat color, meat shear value, muscle pH, and protein solubility. A total of 400 broilers was divided into 5 treatment groups and stunned with 500, 600, 700, 800, and 900 Hz at 15 V for 10 seconds. Blood samples were collected immediately after cutting the neck. Pectoralis major muscles were removed from the carcass after chilling and placed in ice. Breast muscle pH and meat color were determined at both 2 and 24 h postmortem. Drip loss, cooking loss, pressing loss, and cooked breast meat-shear values were determined at 24 h postmortem. Treatment at 500 and 900 Hz significantly increased (P meat color were not affected by stunning frequency. In the 500 and 900 Hz groups, the protein solubility and shear force values were significantly lower (P < 0.05) and drip loss was significantly higher (P < 0.05) than in the 700 Hz group. This study indicates that the waveform of the pulsed direct current is acceptable for stunning broilers at a stunning frequency of 700 Hz. © 2017 Poultry Science Association Inc.

  2. 9 CFR 313.30 - Electrical; stunning or slaughtering with electric current.

    Science.gov (United States)

    2010-01-01

    ... electrical shock shall be such as to produce immediate insensibility to pain in the exposed animal. (4) The... designed to properly accommodate the species of animals being anesthetized. Animals shall be free from pain... material. Power activated gates designed for constant flow of animals shall be so fabricated that they will...

  3. Evaluation of electrical stunning of sea bass (Dicentrarchus labrax) in seawater and killing by chilling: wel;fare aspects, product quality and possibilities for implementation

    NARCIS (Netherlands)

    Lambooij, E.; Gerritzen, M.A.; Reimert, H.G.M.; Burggraaf, D.; Andre, G.; Vis, van de J.W.

    2008-01-01

    The objective was to assess neural, behavioural responses and product quality in farmed sea bass (Dicentrarchus labrax) upon electrical stunning in seawater. The electrical sinusoidal 50 Hz or pulse square wave alternating 133 Hz current induced a general epileptiform insult with a current of

  4. Assessment of electrical stunning in fresh water of African Catfish (Clarias gariepinus) and chilling in ice water for loss of consciousness and sensibility

    NARCIS (Netherlands)

    Lambooij, E.; Kloosterboer, R.J.; Gerritzen, M.A.; Vis, van de J.W.

    2006-01-01

    The overall objective of the study was to evaluate loss of consciousness and sensibility after electrical stunning in fresh water and live chilling in ice water for slaughter of African catfish using measurement of electrical brain and heart activity. To provoke immediate loss of consciousness and

  5. Percussion and electrical stunning of Atlantic salmon (Salmo salar) after dewatering and subsequent effect on brain and heart activities nd subsequent

    NARCIS (Netherlands)

    Lambooij, E.; Grimsboe, E.; Vis, van de J.W.; Reimert, H.G.M.; Nortvedt, R.; Roth, B.

    2010-01-01

    The overall objective of the study was to evaluate a percussive and an electrical stunning method under laboratory conditions in Atlantic salmon. Evidence of unconsciousness and insensibility of the salmon was provided on the electroencephalogram (EEG) by the appearance of slow waves and spikes,

  6. Effects of on-board storage and electrical stunning of wild cod (Gadus morhua) and haddock (Melanogrammus aeglefinus) on brain and heart activity

    NARCIS (Netherlands)

    Lambooij, E.; Digre, H.; Reimert, H.G.M.; Aursand, I.G.; Grimso, L.; Vis, van de J.W.

    2012-01-01

    Cod and haddock captured with commercial trawling gear were taken immediately after landing on deck to on-board storage in dry bins for measuring brain and heart activity, and behaviour. Other groups were first stored in holding tanks and then electrically stunned with a prototype "dry stunner". For

  7. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  8. Effects of feed deprivation and electrical, gas, and captive needle stunning on early postmortem muscle metabolism and subsequent meat quality

    NARCIS (Netherlands)

    Savenije, B; Schreurs, FJG; Winkelman-Goedhart, HA; Gerritzen, MA; Korf, J; Lambooij, E

    The general method for stunning poultry before slaughter is by immersion of a chicken's head into an electrified waterbath. This method results in carcass and meat quality deficiencies. The major problems are hemorrhages and a delay in onset of rigor mortis, which increases the risk of cold

  9. The photovoltaic industry stunned

    International Nuclear Information System (INIS)

    Piro, P.

    2011-01-01

    In December 2010 the French authorities decided a 3-month moratory on any new project of photovoltaic installation (over 3 KWc) because of the huge number of demands that made the cost of the incentive measures soar in an unexpected manner. In March 2011 the moratory was lifted and the professionals have been stunned by the new conditions imposed to benefit from the preferential purchase tariffs of the electricity produced that are far less favourable than previously. The new tariff grid will be adjusted each term according to the volume of demands. While several thousand jobs are at stake, the professionals hope a reversal of the government position as France enters an electoral period. (A.C.)

  10. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  11. Stunning systems for poultry

    Science.gov (United States)

    Poultry are stunned immediately prior to slaughter to facilitate automated processing, to minimize the subsequent death struggle and thereby minimize carcass damage and down grades, and to render the bird unconscious and incapable to perceive pain. A stunning method for slaughter should be consider...

  12. Voltage Support from Electric Vehicles in Distribution Grid

    DEFF Research Database (Denmark)

    Huang, Shaojun; Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2013-01-01

    The paper evaluates the voltage support functions from electric vehicles (EVs) on a typical Danish distribution grid with high EV penetration. In addition to the popular voltage control modes, such as voltage droop charging (low voltage level leads to low charging power) and reactive power support...

  13. Optical sensors for the measurement of electric current and voltage

    Energy Technology Data Exchange (ETDEWEB)

    Rutgers, W R; Hulshof, H J.M.; Laurensse, I J; van der Wey, A H

    1987-01-01

    Optical sensors for the measurement of electrical current and voltage were developed for application in electric power systems. The current sensor, based on the Faraday effect in a monomode glass fiber, and the voltage sensor, based on the transverse Pockels effect in a crystal, are demonstrated in wide-band (10 MHz) interference-free measurements of pulsed currents and impulse voltages.

  14. Controlled Atmosphere Stunning

    NARCIS (Netherlands)

    Lambooij, E.; Gerritzen, M.A.

    2009-01-01

    Controlled atmosphere (CAS) stunning includes several variations of gaseous mixtures given to induce an anaesthetic state before slaughter poultry. One method of multi phase CAS is to unload the birds out of the crate on a conveyor belt and subject the birds to an atmosphere of 30% O2, 40% CO2 and

  15. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    of incorporating electric vehicles (EVs) in a low voltage distribution network with high penetration of photovoltaic installations (PVs), and focuses on analysing potential voltage support functions from EVs and PVs. In addition, the paper evaluates the benefits that reactive power control may provide...

  16. Influence of Voltage on Main Characteristics of Electric Lighting Lamps

    Directory of Open Access Journals (Sweden)

    V. B. Kozlovskaya

    2009-01-01

    Full Text Available An analysis and systemization of data on influence of voltage value on main lighting engineering, electric and economic characteristics of incandescent lamps, gaseous-discharge lamps of low and high pressure have been made in the paper.Analytical and graphical dependences have been obtained that ensure to evaluate quantitative changes of corresponding lamp characteristics at voltage deviation from nominal value.

  17. Copper wire theft and high voltage electrical burns.

    Science.gov (United States)

    Francis, Eamon C; Shelley, Odhran P

    2014-01-01

    High voltage electrical burns are uncommon. However in the midst of our economic recession we are noticing an increasing number of these injuries. Copper wire is a valuable commodity with physical properties as an excellent conductor of electricity making it both ubiquitous in society and prized on the black market. We present two consecutive cases referred to the National Burns Unit who sustained life threatening injuries from the alleged theft of high voltage copper wire and its omnipresence on an international scale.

  18. Copper wire theft and high voltage electrical burns

    OpenAIRE

    Francis, Eamon C; Shelley, Odhran P

    2014-01-01

    High voltage electrical burns are uncommon. However in the midst of our economic recession we are noticing an increasing number of these injuries. Copper wire is a valuable commodity with physical properties as an excellent conductor of electricity making it both ubiquitous in society and prized on the black market. We present two consecutive cases referred to the National Burns Unit who sustained life threatening injuries from the alleged theft of high voltage copper wire and its omnipresenc...

  19. Improved detection of electrical activity with a voltage probe based on a voltage-sensing phosphatase.

    Science.gov (United States)

    Tsutsui, Hidekazu; Jinno, Yuka; Tomita, Akiko; Niino, Yusuke; Yamada, Yoshiyuki; Mikoshiba, Katsuhiko; Miyawaki, Atsushi; Okamura, Yasushi

    2013-09-15

      One of the most awaited techniques in modern physiology is the sensitive detection of spatiotemporal electrical activity in a complex network of excitable cells. The use of genetically encoded voltage probes has been expected to enable such analysis. However, in spite of recent progress, existing probes still suffer from low signal amplitude and/or kinetics too slow to detect fast electrical activity. Here, we have developed an improved voltage probe named Mermaid2, which is based on the voltage-sensor domain of the voltage-sensing phosphatase from Ciona intestinalis and Förster energy transfer between a pair of fluorescent proteins. In mammalian cells, Mermaid2 permits ratiometric readouts of fractional changes of more than 50% over a physiologically relevant voltage range with fast kinetics, and it was used to follow a train of action potentials at frequencies of up to 150 Hz. Mermaid2 was also able to detect single action potentials and subthreshold voltage responses in hippocampal neurons in vitro, in addition to cortical electrical activity evoked by sound stimuli in single trials in living mice.

  20. Vivitron 1995, transient voltage simulation, high voltage insulator tests, electric field calculation

    International Nuclear Information System (INIS)

    Frick, G.; Osswald, F.; Heusch, B.

    1996-01-01

    Preliminary investigations showed clearly that, because of the discrete electrode structure of the Vivitron, important overvoltage leading to insulator damage can appear in case of a spark. The first high voltage tests showed damage connected with such events. This fact leads to a severe voltage limitation. This work describes, at first, studies made to understand the effects of transients and the associated over-voltage appearing in the Vivitron. Then we present the high voltage tests made with full size Vivitron components using the CN 6 MV machine as a pilot machine. Extensive field calculations were made. These involve simulations of static stresses and transient overvoltages, on insulating boards and electrodes. This work gave us the solutions for arrangements and modifications in the machine. After application, the Vivitron runs now without any sparks and damage at 20 MV. In the same manner, we tested column insulators of a new design and so we will find out how to get to higher voltages. Electric field calculation around the tie bars connecting the discrete electrodes together showed field enhancements when the voltages applied on the discrete electrodes are not equally distributed. This fact is one of the sources of discharges and voltage limitations. A scenario of a spark event is described and indications are given how to proceed towards higher voltages, in the 30 MV range. (orig.)

  1. Copper wire theft and high voltage electrical burns

    Science.gov (United States)

    Francis, Eamon C; Shelley, Odhran P

    2014-01-01

    High voltage electrical burns are uncommon. However in the midst of our economic recession we are noticing an increasing number of these injuries. Copper wire is a valuable commodity with physical properties as an excellent conductor of electricity making it both ubiquitous in society and prized on the black market. We present two consecutive cases referred to the National Burns Unit who sustained life threatening injuries from the alleged theft of high voltage copper wire and its omnipresence on an international scale. PMID:25356371

  2. Integration of Electric Vehicles in Low Voltage Danish Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Thøgersen, Paul; Møller, Jan

    2012-01-01

    Electric Vehicles (EVs) are considered as one of the important components of the future intelligent grids. Their role as energy storages in the electricity grid could provide local sustainable solutions to support more renewable energy. In order to estimate the extent of interaction of EVs...... in the electricity grid operation, a careful examination in the local electricity system is essential. This paper investigates the degree of EV penetration and its key influence on the low voltage distribution grids. Three detailed models of residential grids in Denmark are considered as test cases in this study...... it is shown that there is enough head-space on the transformer capacity which can be used to charge many EVs during a day. The overall transformer capability of handling EV loads varies between 6-40% for peak and minimum demand hours, which is dependent on the robustness of the grids. The voltage drops...

  3. Static Electricity as Part of Electromagnetic Environment on High-Voltage Electrical Substation

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2012-01-01

    Full Text Available Causes of occurrences electrostatic discharges (ESD on high-voltage electric substation were investigated and dependences values ESD’s on parameters interaction structures, humidity of air were found. Experimental research values ESD’s on high-voltage electric substation and in man-made conditions was fulfilled. Uncertainty measurement’s was taken into consideration by research results analyze. Matching with research of other authors was made. Danger ESD’s for electric devises was established.

  4. Preslaughter electrical stunning of eels

    NARCIS (Netherlands)

    Robb, D.H.F.; Wotton, S.B.; Vis, van de J.W.

    2002-01-01

    The current procedures for slaughtering European eels (Anguilla anguilla) for food are very slow and cause suffering. Although there is little legislation for protecting the welfare of fish at slaughter, the legislation covering farmed mammals and birds at slaughter is well defined, requiring that

  5. High Voltage Electrical Injuries In The University Of Calabar ...

    African Journals Online (AJOL)

    Even when patients present relatively early and are resuscitated and treated, complete prosthetic rehabilitation is difficult because of poverty and lack of social support systems. Case Report: This review presents three cases of high voltage electrical burns resulting from typical 11KVA burns as well as lightning strike.

  6. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    The proximity effects of high voltage electric power transmission lines on Leyland Cypress (xCupressocyparis leylandii (Dallim. and A.B. Jacks.) Dallim) and Japanese Privet (Ligustrum japonicum Thunb.) growth were examined in a private nursery located in Sakarya, Turkey. Five transect were randomly chosen in both ...

  7. High voltage diagnostics on electrical insulation of supersonducting magnets

    International Nuclear Information System (INIS)

    Irmisch, M.

    1995-12-01

    The high voltage (HV) performance of superconducting magnets of large dimensions, e.g. as needed in fusion reactors, is a challange in the field of high voltage technology, i.e. especially in the field of cryogenic high voltage components and with respect to questions of HV insulation diagnostics at low temperature. By using the development of POLO - a superconducting prototype coil of a tokamak poloidal field coil - as an example, this work deals with special problems of how to get use of conventional HV test techniques for diagnostics under special cryogenic boundary conditions. As a first approach to gain experience in the field of phase resolved partial discharge (PRPD) measurements during operation of a superconductive coil, the POLO coil was subject to several high voltage tests. Compared with DC insulation resistance measurements and capacitive impulse voltage discharges to the coil, the AC PD measurements have been the only way to observe special characteristics of the electrical insulation with respect to the cooling down of the coil from 300 K to 4.2 K. The PRPD measurement technique thereby has proofed as a suitable diagnostic tool. This work can serve as basic data to be comparable within further projects of electrical insulation diagnostics at cryogenic temperatures. (orig.)

  8. The Application of Voltage Transformer Simulator in Electrical Test Training

    Science.gov (United States)

    Li, Nan; Zhang, Jun; Chai, Ziqi; Wang, Jingpeng; Yang, Baowei

    2018-02-01

    The voltage transformer test is an important means to monitor its operating state. The accuracy and reliability of the test data is directly related to the test skill level of the operator. However, the risk of test instruments damage, equipment being tested damage and electric shock in operator is caused by improper operation when training the transformer test. In this paper, a simulation device of voltage transformer is set up, and a simulation model is built for the most common 500kV capacitor voltage transformer (CVT), the simulation model can realize several test items of CVT by combing with teaching guidance platform, simulation instrument, complete set of system software and auxiliary equipment in Changchun. Many successful applications show that the simulation device has good practical value and wide application prospect.

  9. Impact Assessment of Electric Boilers in Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Sinha, Rakesh; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2018-01-01

    Flexibility from the electricity supply, with high share of intermittent energy sources such as wind and solar, has been offered by combined heat and power (CHP) generation in Denmark for decades. There could be periods where the fuel prices are higher than the electricity prices (even -ve), during...... high wind production and is idle for electric boilers (EBs) operation. In the future, using EBs, excess electricity from wind turbines can be effectively utilized for heat production, and still meet the thermal demand by decreasing CHP production. Thus, there is need for demand side flexibility...... control incorporated based on grid voltages, restricts the operation of EBs but ensures operation of the distribution system within limits still trying to keep the thermal comfort in the houses....

  10. Low voltage initiation of damaging arcs between electrical contacts

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1975-07-01

    Metallic arcs were found to precede the firm contacting of electrical contacts which were closed without bounce. When the open-circuit voltages were below the ionization potential, the initiation of these arcs was found to depend on the presence of asperities on the surfaces and on asperity contracting, melting, and pinching off by magnetic forces. The arc is thought to be initiated inductively when the molten metallic asperity contact is pinched off, and the electrode damage is similar to that produced by the arcing of opening contacts. Arcing could not be produced for exceptionally smooth surfaces, or, for rough surfaces when the open-circuit potential was below the melting voltages of the electrode metals. In order to prevent damage to contact surfaces by melting or arcing, it is suggested that test potentials be limited to below the melting voltages, that the current be limited, the test circuits be designed to prevent inductively generated high voltage transients, and the contact surfaces be very smooth. In order to facilitate arc initiation in arc welding applications, it is suggested that the surfaces of electrodes and work pieces be roughened. (U.S.)

  11. Electrical actuation of electrically conducting and insulating droplets using ac and dc voltages

    International Nuclear Information System (INIS)

    Kumari, N; Bahadur, V; Garimella, S V

    2008-01-01

    Electrical actuation of liquid droplets at the microscale offers promising applications in the fields of microfluidics and lab-on-chip devices. Much prior research has targeted the electrical actuation of electrically conducting liquid droplets using dc voltages (classical electrowetting). Electrical actuation of conducting droplets using ac voltages and the actuation of insulating droplets (using dc or ac voltages) has remained relatively unexplored. This paper utilizes an energy-minimization-based analytical framework to study the electrical actuation of a liquid droplet (electrically conducting or insulating) under ac actuation. It is shown that the electromechanical regimes of classical electrowetting, electrowetting under ac actuation and insulating droplet actuation can be extracted from the generic electromechanical actuation framework, depending on the electrical properties of the droplet, the underlying dielectric layer and the frequency of the actuation voltage. This paper also presents experiments which quantify the influence of the ac frequency and the electrical properties of the droplet on its velocity under electrical actuation. The velocities of droplets moving between two parallel plates under ac actuation are experimentally measured; these velocities are then related to the actuation force on the droplet which is predicted by the electromechanical model developed in this work. It is seen that the droplet velocities are strongly dependent on the frequency of the ac actuation voltage; the cut-off ac frequency, above which the droplet fails to actuate, is experimentally determined and related to the electrical conductivity of the liquid. This paper then analyzes and directly compares the various electromechanical regimes for the actuation of droplets in microfluidic applications

  12. Electrical and optical investigations on the low voltage vacuum arc

    International Nuclear Information System (INIS)

    Braic, M.; Braic, V.; Pavelescu, G.; Balaceanu, M.; Pavelescu, D.; Dumitrescu, G.; Gherendi, F.

    2002-01-01

    Preliminary investigations of a low voltage circuit breaker, adapted from a real industrial device, were carried out by electrical and optical methods. Electrical, parameters were measured in the high current arc period and in zero current moment (C.Z) and corroborated with the arc plasma spectroscopic investigations. For the first time in vacuum arc diagnostics, the paper presents results based on single shot time resolved emission spectroscopy around C.Z. The short-circuit current was produced in a special high power installation in order to reproduce exactly the short-circuit regimes developing in low voltage distribution networks. A stainless steel vacuum chamber with classical Cu-Cr electrodes was used. Tests were performed for different current values in the range 3 - 20 kA rms , the voltages being varied between 200 and 1000 V ac . Interruption processes in the different arc regimes (from the diffuse arc mode to the constricted column mode) were analyzed. The success of the arc interruption was analyzed in terms of electric arc energy achieved in the first current halfperiod. The results obtained were corroborated with arc plasma spectroscopic investigations. The emission spectroscopy setup, using an Acton spectrograph and an intensified CCD camera, allowed the spatial and time-resolved investigation of spectra emitted by the vacuum arc plasma. The first truly time-resolved spectroscopic measurements on a single half-period was proven to be a good method to investigate the vacuum arc. Using single shot time resolved spectroscopy around zero current on partial unsuccessful interruption we concluded that the Cu ions, more that Cr ions were responsible for the arc reignition. The financial support for this work comes from NATO-STI SfP /974083 and CORINT-Romania projects. (authors)

  13. Thyristor voltage converter in induction electric drives with microprocessor control

    Energy Technology Data Exchange (ETDEWEB)

    Braslavsky, I.; Zuzev, A.; Shilin, S. [Electric Drive Department, Urals State Technical University, Ekaterinburg (Russian Federation)

    1997-12-31

    The paper consists of some results on developed pulse model of thyristor voltage converter which is one of the most mathematically complicated unit of electric drive. The model structure and model parameter calculating method are represented. The application of the model allows to analyse stability in `locally` by the linear pulse system theory methods with talking into consideration quantise processes within the converter. Such application provides the obtaining higher accurate results comparing with the non-linear system theory approximate methods. Logarithmic frequency characteristics are used to analyse converter dynamic features and they are represented too. (orig.) 4 refs.

  14. Effects of load voltage on voltage breakdown modes of electrical exploding aluminum wires in air

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jian; Li, Xingwen, E-mail: xwli@mail.xjtu.edu.cn; Yang, Zefeng; Wang, Kun; Chao, Youchuang; Shi, Zongqian; Jia, Shenli; Qiu, Aici [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-06-15

    The effects of the load voltage on the breakdown modes are investigated in exploding aluminum wires driven by a 1 kA, 0.1 kA/ns pulsed current in air. From laser probing images taken by laser shadowgraphy, schlieren imaging, and interferometry, the position of the shockwave front, the plasma channel, and the wire core edge of the exploding product can be determined. The breakdown mode makes a transition from the internal mode, which involves breakdown inside the wire core, to the shunting mode, which involves breakdown in the compressed air, with decreasing charging voltage. The breakdown electrical field for a gaseous aluminum wire core of nearly solid density is estimated to be more than 20 kV/cm, while the value for gaseous aluminum of approximately 0.2% solid density decreases to 15–20 kV/cm. The breakdown field in shunting mode is less than 20 kV/cm and is strongly affected by the vaporized aluminum, the desorbed gas, and the electrons emitted from the wire core during the current pause. Ohmic heating during voltage collapses will induce further energy deposition in the current channel and thus will result in different expansion speeds for both the wire core and the shockwave front in the different modes.

  15. Low-voltage electricity-induced lung injury.

    Science.gov (United States)

    Truong, Thai; Le, Thuong Vu; Smith, David L; Kantrow, Stephen P; Tran, Van Ngoc

    2018-02-01

    We report a case of bilateral pulmonary infiltrates and haemoptysis following low-voltage electricity exposure in an agricultural worker. A 58-year-old man standing in water reached for an electric watering machine and sustained an exposure to 220 V circuit for an uncertain duration. The electricity was turned off by another worker, and the patient was asymptomatic for the next 10 h until he developed haemoptysis. A chest radiograph demonstrated bilateral infiltrates, and chest computed tomography (CT) revealed ground-glass opacities with interstitial thickening. Evaluations, including electrocardiogram, serum troponin, N-terminal pro-B-type natriuretic peptide (NT-pro BNP), coagulation studies, and echocardiogram, found no abnormality. The patient was treated for suspected electricity-induced lung injury and bleeding with tranexamic acid and for rhabdomyolysis with volume resuscitation. He recovered with complete resolution of chest radiograph abnormalities by Day 7. This is the first reported case of bilateral lung oedema and/or injury after electricity exposure without cardiac arrest.

  16. Generator voltage stabilisation for series-hybrid electric vehicles.

    Science.gov (United States)

    Stewart, P; Gladwin, D; Stewart, J; Cowley, R

    2008-04-01

    This paper presents a controller for use in speed control of an internal combustion engine for series-hybrid electric vehicle applications. Particular reference is made to the stability of the rectified DC link voltage under load disturbance. In the system under consideration, the primary power source is a four-cylinder normally aspirated gasoline internal combustion engine, which is mechanically coupled to a three-phase permanent magnet AC generator. The generated AC voltage is subsequently rectified to supply a lead-acid battery, and permanent magnet traction motors via three-phase full bridge power electronic inverters. Two complementary performance objectives exist. Firstly to maintain the internal combustion engine at its optimal operating point, and secondly to supply a stable 42 V supply to the traction drive inverters. Achievement of these goals minimises the transient energy storage requirements at the DC link, with a consequent reduction in both weight and cost. These objectives imply constant velocity operation of the internal combustion engine under external load disturbances and changes in both operating conditions and vehicle speed set-points. An electronically operated throttle allows closed loop engine velocity control. System time delays and nonlinearities render closed loop control design extremely problematic. A model-based controller is designed and shown to be effective in controlling the DC link voltage, resulting in the well-conditioned operation of the hybrid vehicle.

  17. Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge

    International Nuclear Information System (INIS)

    Shen Yongjun; Lei Lecheng; Zhang Xingwang; Zhou Minghua; Zhang Yi

    2008-01-01

    Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 x 10 -9 mol/J and 1.95 x 10 -9 mol/J, respectively

  18. Multistage carbon dioxide gas stunning of broilers

    NARCIS (Netherlands)

    Gerritzen, M.A.; Reimert, H.G.M.; Hindle, V.A.; Verhoeven, M.T.W.; Veerkamp, W.B.

    2013-01-01

    The stunning quality of animals for slaughter remains under constant scrutiny. In response to previous research showing low stunning efficiency in poultry, the conventional water bath will be phased out in the Netherlands. Presently, the main practical alternative to water bath stunning of poultry

  19. Electric vehicles integration within low voltage electricity networks & possibilities for distribution energy loss reduction

    NARCIS (Netherlands)

    Lampropoulos, I.; Veldman, E.; Kling, W.L.; Gibescu, M.; Slootweg, J.G.

    2010-01-01

    With the prospect of an increasing number of electric vehicles (EVs) on the road, domestic charging will be the most obvious way to recharge the vehicles’ batteries. However, this can have adverse impacts to low voltage (LV) distribution grids such as high current demand, increased 3-phase load

  20. Application of high voltage electric field (HVEF) drying technology in potato chips

    International Nuclear Information System (INIS)

    Bai, Yaxiang; Shi, Hua; Yang, Yaxin

    2013-01-01

    In order to improve the drying efficiency and qualities of vegetable by high voltage electric field (HVEF), potato chips as a representative of vegetable was dried using a high voltage electric drying systems at 20°C. The shrinkage rate, water absorption and rehydration ratio of dried potato chips were measured. The results indicated that the drying rate of potato chips was significantly improved in the high voltage electric drying systems. The shrinkage rate of potato chips dried by high voltage electric field was 1.1% lower than that by oven drying method. And the rehydration rate of high voltage electric field was 24.6% higher than that by oven drying method. High voltage electric field drying is very advantageous and can be used as a substitute for traditional drying method.

  1. High Voltage Hybrid Electric Propulsion - Multilayered Functional Insulation System (MFIS) NASA-GRC

    Science.gov (United States)

    Lizcano, M.

    2017-01-01

    High power transmission cables pose a key challenge in future Hybrid Electric Propulsion Aircraft. The challenge arises in developing safe transmission lines that can withstand the unique environment found in aircraft while providing megawatts of power. High voltage AC, variable frequency cables do not currently exist and present particular electrical insulation challenges since electrical arcing and high heating are more prevalent at higher voltages and frequencies. Identifying and developing materials that maintain their dielectric properties at high voltage and frequencies is crucial.

  2. Phase-wise enhanced voltage support from electric vehicles in a Danish low-voltage distribution grid

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia

    2016-01-01

    High deployment of electric vehicles (EVs) imposes great challenges for the distribution grids, especially in unbalanced systems with notable voltage variations which detrimentally affect security of supply. On the other hand, with development of Vehicle-to-Grid technology, EVs may be able...... to provide numerous services for grid support, e.g., voltage control. Implemented electronic equipment will allow them to exchange reactive power for autonomous voltage support without communicating with the distribution system operator or influencing the available active power for primary transportation...

  3. Restraining and neck cutting or stunning and neck cutting of veal calves.

    Science.gov (United States)

    Lambooij, E; van der Werf, J T N; Reimert, H G M; Hindle, V A

    2012-05-01

    Brain and heart activities were measured in 31 veal calves during restraining and rotating followed by neck cutting with or without stunning to evaluate welfare. After neck cutting correlation dimension analyses and %power of EEG beta wave fraction decreased gradually to lower values resulting in an induction of unconsciousness lasting on average 80s. Corneal reflex response ceased 135±57s after neck cutting. The CD scores and the %power of beta waves fell immediately after post-cut captive bolt and pre-cut electrical stunning to levels indicating unconsciousness. Heart rate in lairage increased upon entrance to the restrainer and again after rotation, heart rate variability decreased. Rotating the restrainer 90°, 120° or 180° compromised veal calf welfare and should be avoided. It is recommended to use post-cut captive bolt stunning or pre-cut electrical stunning inducing immediate unconsciousness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. The electric strength of high-voltage transformers insulation at effect of partial dischargers

    International Nuclear Information System (INIS)

    Khoshravan, E.; Zeraatparvar, A.; Gashimov, A.M.; Mehdizadeh, R.N.

    2001-01-01

    Full text : In paper the change of electric strength of high-voltage transformers insulation at the effect of partial discharges with space charge accumulation was investigated. It is revealed that the effect of partial discharges of insulation materials results the reduction of their pulsing electric strength which can restore the own initial value at releasing of saved charge the volume of a material under condition of absence the ineversible structural changes in it. Researches of high-voltage transformers insulation's non-failure operation conditions show, that at increasing of insulation work time in a strong electrical field the reduction of average breakdown voltages with simultaneous increasing of spread in discharge voltage values takes place. It authentically testifies to reduction of short-time discharge voltage of insulation materials during their electrical aging. As the basic reason of insulation electrical aging the partial discharges occurring in gas cavities inside insulation were considered. It is known that the space charges will be formed in insulation elements of high-voltage devices which effects in dielectrical property of these elements including the electric strength and the space charge formation can occur also at partial discharges in an alternating voltage while the service of high-voltage transformers. In the given work the experiments in revealing separate influence partial discharges in pulsing electric strength of insulation materials at presence and at absence inside them the space charge were spent

  5. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    Science.gov (United States)

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  6. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  7. Improvement of Local Voltage in Feeders with Photovoltaic using Electric Vehicles

    DEFF Research Database (Denmark)

    Marra, Francesco; Yang, Guangya; Fawzy, Y. T.

    2013-01-01

    In low-voltage (LV) feeders with high penetration of photovoltaic (PV), a major issue to be solved is voltage rise due to the active power injection. If no measures are taken, this may lead to generation’s interruptions and to the malfunctioning of domestic appliances due to non-standard voltage...... profiles. This paper proposes a storage strategy to alleviate voltage rise in feeders with PV, using coordinated electric vehicle (EV) load as the storage solution. The voltage support strategy is easy to implement practically and it is demonstrated on a test feeder emulating a household with roof...

  8. Impurity effects on electrical conductivity of doped bilayer graphene in the presence of a bias voltage

    International Nuclear Information System (INIS)

    Lotfi, E; Rezania, H; Arghavaninia, B; Yarmohammadi, M

    2016-01-01

    We address the electrical conductivity of bilayer graphene as a function of temperature, impurity concentration, and scattering strength in the presence of a finite bias voltage at finite doping, beginning with a description of the tight-binding model using the linear response theory and Green’s function approach. Our results show a linear behavior at high doping for the case of high bias voltage. The effects of electron doping on the electrical conductivity have been studied via changing the electronic chemical potential. We also discuss and analyze how the bias voltage affects the temperature behavior of the electrical conductivity. Finally, we study the behavior of the electrical conductivity as a function of the impurity concentration and scattering strength for different bias voltages and chemical potentials respectively. The electrical conductivity is found to be monotonically decreasing with impurity scattering strength due to the increased scattering among electrons at higher impurity scattering strength. (paper)

  9. Avaliação de diferentes híbridos suínos submetidos à insensibilização elétrica e gasosa (CO2. Parte 1: mensuração de indicadores sanguíneos de estresse Evaluation of pig hybrids stunned with electrical and gaseous (co2 systems. Part 1: blood stress indicators

    Directory of Open Access Journals (Sweden)

    William Bertoloni

    2006-09-01

    Full Text Available Suínos provenientes de três linhagens genéticas A, B e C comercializadas no Brasil, com peso vivo de 100 a 120 kg foram submetidos ao insensibilizador elétrico manual (Karl Schermer 220-230/250 volts, 45-60 Hz e 1,4 -1,5 A e ao sistema gasoso coletivo (COMBI-BUTINA 90% CO2. Alíquotas sanguíneas, para determinação dos níveis de creatina fosfoquinase (CPK, lactato e cortisol, assim como amostras do músculo semimembranosus (10 g para a determinação do gene halotano, foram coletadas. Comparando-se os sistemas de insensibilização elétrico e gasoso (CO2, o elétrico demonstrou ser mais estressante, proporcionando maiores concentrações plasmáticas de cortisol (p Pigs of three genetics lineages A, B and C marketed in Brazil, with alive weight from 100 to 120 kg were submitted to the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 -1.5 A and to the collective gaseous system (COMBI-BUTINA 90% CO2. Blood samples, for levels determination of creatine phosphokinase (CPK, lactate and cortisol, as well as samples of the semimembranosus muscle (10 g for the determination of the gene halothane, were collected. Being compared the electric and gaseous stunning systems, the electric stunning did demonstrate to be more stressful providing larger plasmatic concentrations of cortisol ( p < 0.001 and lactate ( p < 0.001 for the genetic lineages A and C, in the studied conditions.However it didn't observe significant differences beween the sanguine indicators and stunning systems in subject when the lineage B was considered. Significant differences among the genetic lineages A, B and C were obtained being compared the plasmatic values of creatine phosphokinase (p < 0.001, lactate (p < 0.001 and cortisol (p < 0.001 when stunned with the gaseous system, however when the electric system was used only the cortisol values presented significant differences (p < 0.001. The presence of the gene halothane (Nn was only observed in the

  10. Multilayered Functional Insulation System (MFIS) for AC Power Transmission in High Voltage Hybrid Electrical Propulsion

    Science.gov (United States)

    Lizcano, Maricela

    2017-01-01

    High voltage hybrid electric propulsion systems are now pushing new technology development efforts for air transportation. A key challenge in hybrid electric aircraft is safe high voltage distribution and transmission of megawatts of power (>20 MW). For the past two years, a multidisciplinary materials research team at NASA Glenn Research Center has investigated the feasibility of distributing high voltage power on future hybrid electric aircraft. This presentation describes the team's approach to addressing this challenge, significant technical findings, and next steps in GRC's materials research effort for MW power distribution on aircraft.

  11. Voltage Flicker Mitigation in Electric Arc Furnace using D-STATCOM

    OpenAIRE

    Deepthisree Madathil; Ilango Karuppasamy; Kirthika Devi V S; Manjula G Nair

    2014-01-01

    The major power quality issue of voltage flicker has resulted as a serious concern for the customers and heavy power companies. Voltage flicker is an impression of unsteadiness of visual sensation induced by a light source whose luminance fluctuates with time. This phenomenon is experienced when an Electric Arc Furnace (EAF) as load is connected to the power system. Flexible AC transmission devices (FACTS) devices were gradually utilized for voltage flicker reduction. In this paper the FACTS ...

  12. Study of electric field distorted by space charges under positive lightning impulse voltage

    Science.gov (United States)

    Wang, Zezhong; Geng, Yinan

    2018-03-01

    Actually, many insulation problems are related to electric fields. And measuring electric fields is an important research topic of high-voltage engineering. In particular, the electric field distortion caused by space charge is the basis of streamer theory, and thus quantitatively measuring the Poisson electric field caused by space charge is significant to researching the mechanism of air gap discharge. In this paper, we used our photoelectric integrated sensor to measure the electric field distribution in a 1-m rod-plane gap under positive lightning impulse voltage. To verify the reliability of this quantitative measurement, we compared the measured results with calculated results from a numerical simulation. The electric-field time domain waveforms on the axis of the 1-m rod-plane out of the space charge zone were measured with various electrodes. The Poisson electric fields generated by space charge were separated from the Laplace electric field generated by applied voltages, and the amplitudes and variations were measured for various applied voltages and at various locations. This work also supplies the feasible basis for directly measuring strong electric field under high voltage.

  13. Review of the Dynamics of Coalescence and Demulsification by High-Voltage Pulsed Electric Fields

    Directory of Open Access Journals (Sweden)

    Ye Peng

    2016-01-01

    Full Text Available The coalescence of droplets in oil can be implemented rapidly by high-voltage pulse electric field, which is an effective demulsification dehydration technological method. At present, it is widely believed that the main reason of pulse electric field promoting droplets coalescence is the dipole coalescence and oscillation coalescence in pulse electric field, and the optimal coalescence pulse electric field parameters exist. Around the above content, the dynamics of high-voltage pulse electric field promoting the coalescence of emulsified droplets is studied by researchers domestically and abroad. By review, the progress of high-voltage pulse electric field demulsification technology can get a better understanding, which has an effect of throwing a sprat to catch a whale on promoting the industrial application.

  14. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    Directory of Open Access Journals (Sweden)

    Qiang Jiaxi

    2013-01-01

    Full Text Available Batteries, as the main or assistant power source of EV (Electric Vehicle, are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS, the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  15. A novel series connected batteries state of high voltage safety monitor system for electric vehicle application.

    Science.gov (United States)

    Jiaxi, Qiang; Lin, Yang; Jianhui, He; Qisheng, Zhou

    2013-01-01

    Batteries, as the main or assistant power source of EV (Electric Vehicle), are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS), the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  16. Multi-objective optimization control of plug-in electric vehicles in low voltage distribution networks

    DEFF Research Database (Denmark)

    García-Villalobos, J.; Zamora, I.; Knezovic, Katarina

    2016-01-01

    The massive introduction of plug-in electric vehicles (PEVs) into low voltage (LV) distribution networks will lead to several problems, such as: increase of energy losses, decrease of distribution transformer lifetime, lines and transformer overload issues, voltage drops and unbalances...

  17. Study on Earthquake Response of High Voltage Electrical Equipment Coupling System with Flexible Busbar

    Science.gov (United States)

    Liu, Chuncheng; Qu, Da; Wang, Chongyang; Lv, Chunlei; Li, Guoqiang

    2017-12-01

    With the rapid development of technology and society, all walks of life in China are becoming more and more dependent on power systems. When earthquake occurs, the electrical equipment of substation is prone to damage because of its own structural features, top-heavy, and brittleness of main body. At the same time, due to the complex coupling of the soft electrical connection of substation electrical equipment, the negative impact can not be estimated. In this paper, the finite element model of the coupling system of the single unit of high voltage electrical equipment with the connecting soft bus is established and the seismic response is analysed. The results showed that there is a significant difference between the simple analysis for the seismic response of electrical equipment monomer and the analytical results of electrical equipment systems, and the impact on different electrical equipment is different. It lays a foundation for the future development of seismic performance analysis of extra high voltage electrical equipment.

  18. Electric field analysis of extra high voltage (EHV) underground cables using finite element method

    DEFF Research Database (Denmark)

    Kumar, Mantosh; Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar

    2017-01-01

    used for the insulator due electrical, thermal or environmental stress. Most of these problems are related to the electric field stress on the insulation of the underground cables. The objective of the electric field analysis by using different numerical techniques is to find electric field stress...... electric field stress and other parameters of EHV underground cables with given boundary conditions using 2-D electric field analysis software package (IES-ELECTRO module) which is based on the finite element method (FEM).......Transmission and Distribution of electric power through underground cables is a viable alternative to overhead lines, particularly in residential or highly populated areas. The electrical stresses are consequences of regular voltages and over voltages and the thermal stresses are related to heat...

  19. High voltage transmission of electrical energy over long distances

    Energy Technology Data Exchange (ETDEWEB)

    Tewari, S W

    1962-07-01

    Technical aspects of ac transmission lines, additional means of improving stability ac transmisson lines, insulation problems, ac transmission by cables, high voltage dc transmission, advantages of dc over ac transmission, disadvantages of dc transmission, use of underground cables for dc transmission, history of the development of conversion equipment; transmission schemes adopted on Gotland Island, Sweden; and economics of ac and dc transmission are discussed.

  20. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  1. Frequency-Control Reserves and Voltage Support from Electric Vehicles

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2013-01-01

    The increasing penetration of variable wind power generation units and electricity consumption in power systems demands additional ancillary services for its reliable operation. The battery storages of electric vehicles are one of the substitute solutions for replacing conventional fossil......-fuelled generators to supply future grid support functions. The quick start and fast response characteristics of battery storages enable the electric vehicles to provide most of the power system auxiliary tasks. This chapter discusses key ancillary services that could be supplied by electric vehicles to maintain...... the system balance in power systems with high volumes of wind power generation. To analyse the applications and performance of electric vehicles in supplying active power balancing services, the case studies simulated in wind-power-dominated Danish power systems are also presented....

  2. Power quality issues into a Danish low-voltage grid with electric vehicles

    DEFF Research Database (Denmark)

    Marra, Francesco; Jensen, Morten M.; Garcia-Valle, Rodrigo

    2011-01-01

    An increased interest on electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs) is dealing with their introduction into low voltage (LV) distribution grids. Lately, analysis on power quality issues has received attention when considering EVs as additional load. The charging of EVs...

  3. Impact of plug-in electric vehicles on voltage unbalance in ...

    African Journals Online (AJOL)

    Plug-in electric vehicle (PEV) will soon be connected to residential distribution networks. ... generation units which transfer the energy stored in their battery into grid. ... electric vehicles on voltage imbalance in distribution system is presented. ... and other types of distribution generator such as solar photovoltaic and wind ...

  4. Electrical engineering unit for the reactive power control of the load bus at the voltage instability

    Science.gov (United States)

    Kotenev, A. V.; Kotenev, V. I.; Kochetkov, V. V.; Elkin, D. A.

    2018-01-01

    For the purpose of reactive power control error reduction and decrease of the voltage sags in the electric power system caused by the asynchronous motors started the mathematical model of the load bus was developed. The model was built up of the sub-models of the following elements: a transformer, a transmission line, a synchronous and an asynchronous loads and a capacitor bank load, and represents the automatic reactive power control system taking into account electromagnetic processes of the asynchronous motors started and reactive power changing of the electric power system elements caused by the voltage fluctuation. The active power/time and reactive power/time characteristics based on the recommended procedure of the equivalent electric circuit parameters calculation were obtained. The derived automatic reactive power control system was shown to eliminate the voltage sags in the electric power system caused by the asynchronous motors started.

  5. Electrical Tree Initiation and Growth in Silicone Rubber under Combined DC-Pulse Voltage

    Directory of Open Access Journals (Sweden)

    Tao Han

    2018-03-01

    Full Text Available Electrical tree is a serious threat to silicone rubber (SIR insulation and can even cause breakdown. Electrical trees under alternating current (AC and direct current (DC voltage have been widely researched. While there are pulses in high-voltage direct current (HVDC cables under operating conditions caused by lightning and operating overvoltage in the power system, little research has been reported about trees under combined DC-pulse voltage. Their inception and growth mechanism is still not clear. In this paper, electrical trees are studied under several types of combined DC-pulse voltage. The initiation and growth process was recorded by a digital microscope system. The experimental results indicate that the inception pulse voltage is different under each voltage type and is influenced by the combined DC. The initial tree has two structures, determined by the pulse polarity. With increased DC prestressing time, tree inception pulse voltage with the same polarity is clearly decreased. Moreover, a special initial bubble tree was observed after the prestressing DC.

  6. Potentially damaging failure modes of high- and medium-voltage electrical equipment

    International Nuclear Information System (INIS)

    Hoy, H.C.

    1984-01-01

    The high- and medium-voltage electrical equipment failures of both nuclear and nonnuclear electric utilities have been reviewed for possible disruptive failure modes that would be of special concern in a nuclear power plant. The resulting emphasis was on the electrical faults of transformers, switchgear (circuit breakers), lightning (surge) arrestors, high-voltage cabling and buswork, control boards, and other electrical equipment that, through failure, can be the initiating event that may expand the original fault to nearby or associated equipment. Many failures of such equipment were found and documented, although the failure rate of electrical equipment in utilities is historically quite low. Nuclear plants record too few failures to be statistically valid, but failures that have been recorded show that good design usually restricts the failure to a single piece of equipment. Conclusions and recommendations pertaining to the design, maintenance, and operation of the affected electrical equipment are presented

  7. Assessment of the voltage level and losses with photovoltaic and electric vehicle in low voltage network

    NARCIS (Netherlands)

    Ye, G.; Xiang, Y.; Cobben, J.F.G.

    2014-01-01

    Livelab from Alliander, a network operator, is a program which started to measure electrical and power quality data in the Dutch distribution network since 2013. A proper probability distribution can be used to model load distribution on feeders. This paper presents a methodology to generate the

  8. EFFECT OF TECHNIQUE OF ELECTRICAL STUNNING ON ...

    African Journals Online (AJOL)

    muscle glycolysis, rigor development, temperature, colour as well as cooking loss of the muscles of baconer pigs. hocedure. Eighteen l-andrace x large White baconer pigs, raised under standard conditions, were used for this ex- periment. On reaching a live mas of 82 t5 kg, feed was withheld for one day from 2 previously ...

  9. Effect of resin composition to the electrical and mechanical properties of high voltage insulator material

    International Nuclear Information System (INIS)

    Totok Dermawan; Elin Nuraini; Suyamto

    2012-01-01

    A solid insulator manufacture of resins for high voltage with a variation of resin and hardener composition has been made. The purpose of research to know electrical and mechanical properties of high voltage insulator material of resin. To determine its electric properties, the material is tested its breakdown voltage and the flashover voltage that occurred on the surface. While to determine the mechanical properties were tested by measuring its strength with a tensile test. From testing with variety of mixed composition it is known that for composition between hardener and resin of 1 : 800 has most advantageous properties because it has good strength with a tensile strength of 19.86 MPa and enough high dielectric strength of 43.2 kV / mm). (author)

  10. A New Contribution in Reducing Electric Field Distribution Within/Around Medium Voltage Underground Cable Terminations

    Directory of Open Access Journals (Sweden)

    S. S. Desouky

    2017-10-01

    Full Text Available Ιn medium voltage cables, the stress control layers play an important part in controlling the electric field distribution around the medium voltage underground cable terminations. Underground cable accessories, used in medium voltage cable systems, need a stress control tube in order to maintain and control the insulation level which is designed for long life times. The term “electrical stress control” refers to the cable termination analysis of optimizing the electrical stress in the area of insulation shield cutback to reduce the electrical field concentration at this point in order to reduce breakdown in the cable insulation. This paper presents the effect of some materials of different relative permittivities and geometrical regulation with the curved shape stress relief cones on the electric field distribution of cable termination. The optimization was done by comparing the results of eight materials used. Also, the effect of the change in the thickness of the stress control tube is presented. The modeling design is very important for engineers to find the optimal solution of terminator design of medium voltage cables. This paper also describes the evolution of stress control systems and their benefits. A developed program using Finite Element Method (FEM has calculated a numerical study to the stress control layering electric field distribution.

  11. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

    Science.gov (United States)

    Armstrong, Michael J.; Blackwelder, Mark; Bollman, Andrew; Ross, Christine; Campbell, Angela; Jones, Catherine; Norman, Patrick

    2015-01-01

    The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

  12. Evaluation of diagnostic technique for degradation of low-voltage electric cables with silicone rubber insulator

    International Nuclear Information System (INIS)

    Mikami, Masao

    2005-01-01

    As a part of countermeasures against ageing problems of nuclear power plants, it is requested to establish non-destructive diagnostic technique for their degradation of low voltage electric cables and assessment standard of their life. Having aimed at investigating the degradation of low-voltage electric cable with silicone rubber insulator, change of its surface hardness at elevated temperature were measured by indenter modules. Moreover, we also measured the elongation at break, which is regarded as general degradation index of electric cables, and the surface hardness with a micro hardness meter. Consequently, it is seen that the indenter modulus measurement is (1) capable to obtain general feature of the thermal degradation of silicone rubber insulator, (2) applicable to diagnose the degree of degradation of the electric cable by converting the result to elongation at break, (3) well correlated with the hardness measurement of the electric cable with the micro hardness meter. (author)

  13. An analytical model for the vertical electric field distribution and optimization of high voltage REBULF LDMOS

    International Nuclear Information System (INIS)

    Hu Xia-Rong; Lü Rui

    2014-01-01

    In this paper, an analytical model for the vertical electric field distribution and optimization of a high voltage-reduced bulk field (REBULF) lateral double-diffused metal—oxide-semiconductor (LDMOS) transistor is presented. The dependences of the breakdown voltage on the buried n-layer depth, thickness, and doping concentration are discussed in detail. The REBULF criterion and the optimal vertical electric field distribution condition are derived on the basis of the optimization of the electric field distribution. The breakdown voltage of the REBULF LDMOS transistor is always higher than that of a single reduced surface field (RESURF) LDMOS transistor, and both analytical and numerical results show that it is better to make a thick n-layer buried deep into the p-substrate. (interdisciplinary physics and related areas of science and technology)

  14. Brachial artery protected by wrapped latissimus dorsi muscle flap in high voltage electrical injury

    Science.gov (United States)

    Gencel, E.; Eser, C.; Kokacya, O.; Kesiktas, E.; Yavuz, M.

    2016-01-01

    Summary High voltage electrical injury can disrupt the vascular system and lead to extremity amputations. It is important to protect main vessels from progressive burn necrosis in order to salvage a limb. The brachial artery should be totally isolated from the burned area by a muscle flap to prevent vessel disruption. In this study, we report the use of a wrap-around latissimus dorsi muscle flap to protect a skeletonized brachial artery in a high voltage electrical injury in order to salvage the upper extremity and restore function. The flap wrapped around the exposed brachial artery segment and luminal status of the artery was assessed using magnetic resonance angiography. No vascular intervention was required. The flap survived completely with good elbow function. Extremity amputation was not encountered. This method using a latissimus dorsi flap allows the surgeon to protect the main upper extremity artery and reconstruct arm defects, which contributes to restoring arm function in high voltage electrical injury. PMID:28149236

  15. Pulsed high voltage electric discharge disinfection of microbially contaminated liquids.

    Science.gov (United States)

    Anpilov, A M; Barkhudarov, E M; Christofi, N; Kop'ev, V A; Kossyi, I A; Taktakishvili, M I; Zadiraka, Y

    2002-01-01

    To examine the use of a novel multielectrode slipping surface discharge (SSD) treatment system, capable of pulsed plasma discharge directly in water, in killing micro-organisms. Potable water containing Escherichia coli and somatic coliphages was treated with pulsed electric discharges generated by the SSD. The SSD system was highly efficient in the microbial disinfection of water with a low energy utilization (eta approximately 10-4 kW h l-1). The SSD treatment was effective in the destruction of E. coli and its coliphages through the generation of u.v. radiation, ozone and free radicals. The non-thermal treatment method can be used for the eradication of micro-organisms in a range of contaminated liquids, including milk, negating the use of pasteurization. The method utilizes multipoint electric discharges capable of treating large volumes of liquid under static and flowing regimes.

  16. Effects of a low-voltage static electric field on energy metabolism in astrocytes.

    Science.gov (United States)

    Huang, R; Peng, L; Hertz, L

    1997-01-01

    Mouse astrocytes (glial cells) in primary cultures were exposed to a low-voltage static DC electric field with no current flow and thus with no generation of magnetic fields. The electric field altered the rate of glycolysis, measured by 2-deoxyglucose accumulation. The magnitude and direction of this effect depended on the polarization of the field and the applied voltage. The maximum effect was an increase of approximately 30%, which occurred with field across the cells at an intensity that can be calculated to be 0.3 mV/cm or less. Reversal of the polarization converted the stimulation to a small but statistically significant inhibition.

  17. Some biological effects of high-voltage stationary electric fields

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, V.V.; Dobrov, N.N.; Drobyshev, V.I.; Koroleva, L.V.; Nikitin, M.D.; Petrukhin, S.V.; Semonova, L.A.; Fedorov, V.P.

    The experiments were carried out on 345 white mice using hematological and pathomorphological procedures. The constant electric field (CEF) was generated in a special laboratory device. The exposure to CEF of 50 and 100 kV/m for 20 s caused hematological and morphological changes typical of the anxiety stage of the adaptation syndrome. The exposure also produced morphological changes of reactive and destructive type in skeletal muscles and different segments of kinesthetic receptors. The level of the above changes appears to be directly related to the CEF strength. 6 references, 4 figures, 1 table.

  18. The Architecture Design of Detection and Calibration System for High-voltage Electrical Equipment

    Science.gov (United States)

    Ma, Y.; Lin, Y.; Yang, Y.; Gu, Ch; Yang, F.; Zou, L. D.

    2018-01-01

    With the construction of Material Quality Inspection Center of Shandong electric power company, Electric Power Research Institute takes on more jobs on quality analysis and laboratory calibration for high-voltage electrical equipment, and informationization construction becomes urgent. In the paper we design a consolidated system, which implements the electronic management and online automation process for material sampling, test apparatus detection and field test. In the three jobs we use QR code scanning, online Word editing and electronic signature. These techniques simplify the complex process of warehouse management and testing report transferring, and largely reduce the manual procedure. The construction of the standardized detection information platform realizes the integrated management of high-voltage electrical equipment from their networking, running to periodic detection. According to system operation evaluation, the speed of transferring report is doubled, and querying data is also easier and faster.

  19. Electric Boiler and Heat Pump Thermo-Electrical Models for Demand Side Management Analysis in Low Voltage Grids

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Bak-Jensen, Birgitte; Chen, Zhe

    2013-01-01

    The last fifteen years many European countries have integrated large percentage of renewable energy on their electricity generation mix. In Denmark the 21.3% of the electricity consumed nowadays is produced by the wind, and it has planned to be the 50% by 2025. In order to front future challenges...... on the power system control and operation, created by this unstable way of generation, Demand Side Management turns to be a promising solution. The storage capacity from thermo-electric units, like electric boilers and heat pumps, allows operating them with certain freedom. Hence they can be employed under...... certain coordination, to actively respond to the power system fluctuations. The following paper presents two simple thermo-electrical models of an electrical boiler and an air-source CO2 heat pump system. The purpose is using them in low voltage grids analysis to assess their capacity and flexibility...

  20. High-voltage electrical burns due to copper theft - Case series.

    Science.gov (United States)

    Braga, M J; Oliveira, I; Egipto, P; Silva, A

    2016-03-31

    Electrical burns are among the most devastating trauma inflicted on the human body. These burns have a higher morbidity, length of stay and a much higher risk of amputation than any other type of burn. Electrical burns affect mostly young, working males because they are more frequently the result of a work accident. However, possibly due to the worldwide economic crisis, we are experiencing a new phenomenon: the theft of high-voltage copper wiring.

  1. High-voltage electrical burns due to copper theft – Case series

    Science.gov (United States)

    Braga, M.J.; Oliveira, I.; Egipto, P.; Silva, A.

    2016-01-01

    Summary Electrical burns are among the most devastating trauma inflicted on the human body. These burns have a higher morbidity, length of stay and a much higher risk of amputation than any other type of burn. Electrical burns affect mostly young, working males because they are more frequently the result of a work accident. However, possibly due to the worldwide economic crisis, we are experiencing a new phenomenon: the theft of high-voltage copper wiring. PMID:27857650

  2. Structural health monitoring of high voltage electrical switch ceramic insulators in seismic areas

    OpenAIRE

    REBILLAT, Marc; BARTHES, Clément; MECHBAL, Nazih; MOSALAM, Khalid M.

    2014-01-01

    International audience; High voltage electrical switches are crucial components to restart rapidly the electrical network right after an earthquake. But there currently exists no automatic procedure to check if these ceramic insulators have suffered after an earthquake, and there exists no method to recertify a given switch. To deploy a vibration-based structural health monitoring method on ceramic insulators a large shake table able to generate accelerations up to 3 g was used. The idea unde...

  3. ENEL high and medium voltage electrical substations for power supply to urban centers

    International Nuclear Information System (INIS)

    Bargigia, A.; Boatto, C.; Di Mario, A.; Fava, N.; Sciarra, S.; Speziali, R.

    1991-12-01

    Modular high and medium voltage gas insulated electrical substations are being used by ENEL (Italian Electricity Board) to meet the specific needs of urban centers with special design and sizing constraints of a historical/architectural nature. This paper illustrates the key design, construction operation and performance characteristics of these standardized units. The descriptions include brief notes on equipment-transformer interconnection, interchangeability and environmental compatibility. Performance test procedures and results of actual reliability and certification tests on some substations are reported

  4. Effects of stunning with different carbon dioxide concentrations and exposure times on suckling lamb meat quality.

    Science.gov (United States)

    Bórnez, R; Linares, M B; Vergara, H

    2009-03-01

    Forty-nine Manchega breed male suckling lambs were used to determine the effect of different stunning methods (using two different CO2 concentrations and exposure times) on lamb meat quality. The lambs were allocated to five stunning treatments including four CO2 treatments [80% CO2 for 90s (G1); 90% CO2 for 90s (G2); 90% CO2 for 60s (G3); 80% CO2 for 60s (G4)] and an electrically stunned control group (G5). The gas-stunning treatments did not cause neither haematomas nor blood splash in the carcasses. Meat quality was evaluated by testing pH, colour (L(∗), a(∗), b(∗), chroma, hue values), water holding capacity (WHC), cooking loss (CL), shear force (SF), drip loss (DL) and total aerobic bacteria. Statistical differences in pH at 24h post-mortem, colour, WHC and CL were not found among groups. After 7 days post-mortem, there were statistical differences among groups in pH (highest in G4 and G5) and in DL (highest in G1). There were differences in SF due to stunning method evident after 72h and 7 days ageing. The statistical differences (Plambs since a highest stability with ageing time on meat quality was found using 90% CO2.

  5. Effect of applied voltage parameters on the electric characteristics of a DBD in coaxial electrode configuration

    NARCIS (Netherlands)

    Petrovic, D.; Martens, T.; De Bie, C.; Brok, W.J.M.; Bogaerts, A.; Schmidt, J.; Simek, M.; Pekarek, S.

    2009-01-01

    A numerical parameter study has been performed for a cylindrical atmospheric pressure dielectric barrier discharge (DBD) in helium with nitrogen impurities using a two-dimensional time dependent fluid model. The calculated electric currents and gap voltages as a function of time for a given applied

  6. Electric field control methods for foil coils in high-voltage linear actuators

    NARCIS (Netherlands)

    Beek, van T.A.; Jansen, J.W.; Lomonova, E.A.

    2015-01-01

    This paper describes multiple electric field control methods for foil coils in high-voltage coreless linear actuators. The field control methods are evaluated using 2-D and 3-D boundary element methods. A comparison is presented between the field control methods and their ability to mitigate

  7. A humane protocol for electro-stunning and killing of Nile tilapia in fresh water

    NARCIS (Netherlands)

    Lambooij, E.; Gerritzen, M.A.; Reimert, H.G.M.; Burggraaf, D.; Vis, van de J.W.

    2008-01-01

    Behavioural, neural and physiological parameters were scored after electro-stunning of Nile tilapia (Oreochromis niloticus) in three positions to an electric field in fresh water. An overall current density, 1.0 Arms/dm2, 50 Hz sinusoidal, applied for 1 s top-to-bottom in water (700 ¿S/cm), induced

  8. Sensory quality of broiler breast meat influenced by low atmospheric pressure stunning, deboning time and cooking methods.

    Science.gov (United States)

    Schilling, M W; Radhakrishnan, V; Vizzier-Thaxton, Y; Christensen, K; Williams, J B; Joseph, P

    2015-06-01

    Stunning method (low atmospheric pressure stunning, LAPS and electrical stunning, ES), deboning time (0.75 h and 4 h), and cooking method (baking, frying, and sous vide) were evaluated for their impact on the descriptive sensory characteristics and consumer acceptability of breast meat (n=576, 144 birds per stunning × deboning time combination). Sensory evaluation was conducted by trained descriptive (n=8) and consumer (n=185) panels. On average, no differences (P>0.05) existed in the sensory acceptability of fried and sous vide cooked broiler breast treatment combinations. However, for oven-baking, the LAPS treatment that was deboned at 4 h was more acceptable (Pbaked chicken breast was highly acceptable preferred (Pcharacteristics when baked. © 2015 Poultry Science Association Inc.

  9. Optimization of Pockels electric field in transverse modulated optical voltage sensor

    Science.gov (United States)

    Huang, Yifan; Xu, Qifeng; Chen, Kun-Long; Zhou, Jie

    2018-05-01

    This paper investigates the possibilities of optimizing the Pockels electric field in a transverse modulated optical voltage sensor with a spherical electrode structure. The simulations show that due to the edge effect and the electric field concentrations and distortions, the electric field distributions in the crystal are non-uniform. In this case, a tiny variation in the light path leads to an integral error of more than 0.5%. Moreover, a 2D model cannot effectively represent the edge effect, so a 3D model is employed to optimize the electric field distributions. Furthermore, a new method to attach a quartz crystal to the electro-optic crystal along the electric field direction is proposed to improve the non-uniformity of the electric field. The integral error is reduced therefore from 0.5% to 0.015% and less. The proposed method is simple, practical and effective, and it has been validated by numerical simulations and experimental tests.

  10. A study of preslaughter pig handling and stunning in selected South African Highveld Region abattoirs

    Directory of Open Access Journals (Sweden)

    B.T. Spencer

    2010-05-01

    Full Text Available The study hypothesis was that pre-slaughter handling is not conducted in such a way that pigs can be considered humanely slaughtered, nor is it conducive to promoting those properties of fresh meat that could enhance pork quality. The 1st phase of the investigation was aimed at confirming the present compliance level within the prescribed norms. To this end the importance of stunning induction requirements for effective electrical stunning, the welfare implications relating to the pre-slaughter handling of pigs and the stunning and sticking techniques were investigated. Pre-slaughter welfare of the pigs at the abattoir was found to be influenced at the outset by the origin and type of pig slaughtered, the daily throughput range of pigs and the type of abattoir involved. A disappointing pre-arrival aspect was that deficiencies in road motor vehicles were observed while off-loading pigs. Through poor design or lack of maintenance, another factor that hampered free movement of pigs was the off-loading facilities. The nature of animal behaviour in the pens, in the passages and when going into the stunning area was directly related to the pig handling efficiency and to the nature and extent of design and maintenance problems with equipment. None of the abattoirs had a well designed in-feed to a well planned stunning area / facility, and a very high level of pig pre-slaughter stress prevailed. The optimum position of the electrodes is virtually impossible to attain under practical conditions and the practice of repeat application of electrical stunning is common. Of the total sample size (n = 1175, 34% were difficult to shackle, 90% of these being from the abattoirs tending to slaughter more routinely a wide range of different sized pigs. In this survey 149 pigs (13 % required more than a single sticking attempt to bleed out properly, considerably higher than in other published reports.

  11. The Influence of Stunning Method, Refrigeration and Freezing Time on the Rheological and Textural Properties of Raw Meat

    Directory of Open Access Journals (Sweden)

    Liliana Tudoreanu

    2013-11-01

    Full Text Available The present research was conducted to provide information on the influence of stunning methods in conjunction with refrigeration and freezing time on the textural and rheological properties of raw meat. Pork raw meat, commercially available, was analyzed for textural properties such as hardness, cohesiveness, adhesiveness and fracture force. Sample were analyzed fresh, after 3 days of refrigeration, and 15 days, 30days and 60 days freezing time in commercially available refrigerators mimicking the storing conditions used by consumers. For pork raw meat, hardness increased sharply after 3 days of refrigeration and showed no significant differences after 15days of freezing compared to 3days refrigeration time. After 30 days of freezing the raw pork meat samples’ hardness decreased significantly compared to the hardness of the samples freeze for15 days. Hardness of gas stunning raw pork meat samples compared to electrical stunning raw pork meat samples was 2.57 times higher indicating a better firmness of the gas stunning raw pork meat. The cohesiveness of the raw pork meat from gas stunned animals maintained its levels after 60 days of freezing while the meat from electrically stunned animals showed significant modificatio

  12. Non-canonical spectral decomposition of random functions of the traction voltage and current in electric transportation systems

    Directory of Open Access Journals (Sweden)

    N.A. Kostin

    2015-03-01

    Full Text Available The paper proposes the non-canonical spectral decomposition of random functions of the traction voltages and currents. This decomposition is adapted for the electric transportation systems. The numerical representation is carried out for the random function of voltage on the pantograph of electric locomotives VL8 and DE1.

  13. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid (AVC-TeDP)

    Science.gov (United States)

    Gemin, Paul; Kupiszewski, Tom; Radun, Arthur; Pan, Yan; Lai, Rixin; Zhang, Di; Wang, Ruxi; Wu, Xinhui; Jiang, Yan; Galioto, Steve; hide

    2015-01-01

    The purpose of this effort was to advance the selection, characterization, and modeling of a propulsion electric grid for a Turboelectric Distributed Propulsion (TeDP) system for transport aircraft. The TeDP aircraft would constitute a miniature electric grid with 50 MW or more of total power, two or more generators, redundant transmission lines, and multiple electric motors driving propulsion fans. The study proposed power system architectures, investigated electromechanical and solid state circuit breakers, estimated the impact of the system voltage on system mass, and recommended DC bus voltage range. The study assumed an all cryogenic power system. Detailed assumptions within the study include hybrid circuit breakers, a two cryogen system, and supercritical cyrogens. A dynamic model was developed to investigate control and parameter selection.

  14. Enhancing Food Processing by Pulsed and High Voltage Electric Fields: Principles and Applications.

    Science.gov (United States)

    Wang, Qijun; Li, Yifei; Sun, Da-Wen; Zhu, Zhiwei

    2018-02-02

    Improvements in living standards result in a growing demand for food with high quality attributes including freshness, nutrition and safety. However, current industrial processing methods rely on traditional thermal and chemical methods, such as sterilization and solvent extraction, which could induce negative effects on food quality and safety. The electric fields (EFs) involving pulsed electric fields (PEFs) and high voltage electric fields (HVEFs) have been studied and developed for assisting and enhancing various food processes. In this review, the principles and applications of pulsed and high voltage electric fields are described in details for a range of food processes, including microbial inactivation, component extraction, and winemaking, thawing and drying, freezing and enzymatic inactivation. Moreover, the advantages and limitations of electric field related technologies are discussed to foresee future developments in the food industry. This review demonstrates that electric field technology has a great potential to enhance food processing by supplementing or replacing the conventional methods employed in different food manufacturing processes. Successful industrial applications of electric field treatments have been achieved in some areas such as microbial inactivation and extraction. However, investigations of HVEFs are still in an early stage and translating the technology into industrial applications need further research efforts.

  15. Electrical and optical characteristics of dielectric-barrier discharge driven by high voltage nanosecond generator

    International Nuclear Information System (INIS)

    Ahmadeev, V.V.; Kost'yuchenko, S.V.; Kudryavtsev, N.N.; Kurkin, G.A.; Vasilyak, L.M.

    1998-01-01

    Electrical and optical characteristics of the dielectric-barrier discharge in the pressure range of 10-400 Torr were investigated experimentally, particular attention being paid to the discharge homogeneity and to the energy dissipation in the discharge volume. The discharge was driven by a high-voltage pulse generator producing nanosecond high-voltage pulses with an amplitude of 20-30 kV. Air, nitrogen, and helium were used as working gases. The discharge was found to be homogeneous within a wide range of gas pressure. A power density of up to 250 mW/cm 3 has been achieved. (J.U.)

  16. The Preceding Voltage Pulse and Separation Welding Mechanism of Electrical Contacts

    DEFF Research Database (Denmark)

    Yang, Xiao Cheng; Huang, Jiang; Li, Zhen Biao

    2016-01-01

    In order to obtain a better understanding of the welding mechanism in contact separation, electrical endurance tests were conducted with AgSnO2 and AgNi contacts on a simulation test device. Waveforms of contact displacement, contact voltage, and current were recorded with LabVIEW during the tests......, and changes in a contact gap and heights of pips with increases in operation cycles were observed through charge-coupled device cameras. The resultant test results show that welding in separation is accompanied with a preceding voltage pulse which represents arc rather than contact bounce arc....

  17. Background voltage distortion influence on power electric systems in the presence of the Steinmetz circuit

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, Luis; Pedra, Joaquin [Department of Electrical Engineering, ETSEIB-UPC, Av. Diagonal 647, 08028 Barcelona (Spain); Caro, Manuel [IDOM Ingenieria y Arquitectura, C. Barcas 2, 46002 Valencia (Spain)

    2009-01-15

    In traction systems, it is usual to connect reactances in delta configuration with single-phase loads to reduce voltage unbalances and avoid electric system operation problems. This set is known as Steinmetz circuit. Parallel and series resonances can occur due to the capacitive reactance of the Steinmetz circuit and affect power quality. In this paper, the series resonance ''observed'' from the supply system is numerically located. The study of this resonance is important to avoid problems due to background voltage distortion. Experimental measurements are also presented to validate the obtained numerical results. (author)

  18. The design, construction, and operation of long-distance high-voltage electricity transmission technologies.

    Energy Technology Data Exchange (ETDEWEB)

    Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

    2008-03-03

    This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these

  19. A new SOI high-voltage device with a step-thickness drift region and its analytical model for the electric field and breakdown voltage

    International Nuclear Information System (INIS)

    Luo Xiaorong; Zhang Wei; Zhang Bo; Li Zhaoji; Yang Shouguo; Zhan Zhan; Fu Daping

    2008-01-01

    A new SOI high-voltage device with a step-thickness drift region (ST SOI) and its analytical model for the two-dimension electric field distribution and the breakdown voltage are proposed. The electric field in the drift region is modulated and that of the buried layer is enhanced by the variable thickness SOI layer, thereby resulting in the enhancement of the breakdown voltage. Based on the Poisson equation, the expression for the two-dimension electric field distribution is presented taking the modulation effect into account, from which the RESURF (REduced SURface Field) condition and the approximate but explicit expression for the maximal breakdown voltage are derived. The analytical model can explain the effects of the device parameters, such as the step height and the step length of the SOI layer, the doping concentration and the buried oxide thickness, on the electric field distribution and the breakdown voltage. The validity of this model is demonstrated by a comparison with numerical simulations. Improvement on both the breakdown voltage and the on-resistance (R on ) for the ST SOI is obtained due to the variable thickness SOI layer

  20. Influence Voltage Pulse Electrical Discharge In The Water at the Endurance Fatigue Of Carbon Steel

    Directory of Open Access Journals (Sweden)

    I.A. Vakulenko

    2016-05-01

    Full Text Available Effect of pulses of electrical discharge in the water at the magnitude of the limited endurance under cyclic loading thermally hardened carbon steel was investigated. Observed increase stamina during cyclic loading a corresponding increase in the number of accumulated dislocations on the fracture surface. Using the equation of Cofino-Manson has revealed a decrease of strain loading cycle after treatment discharges. For field-cycle fatigue as a result of processing the voltage pulses carbon steel structure improvement, followed by growth of limited endurance decrease per cycle of deformation. With increasing amplitude of the voltage loop gain stamina effect on metal processing voltage pulses is reduced. The results can be used to extend the life of parts that are subject to cyclic loading.

  1. Voltage inverter with push-pull topology to inject energy into electrical systems with modulation SPWM

    Directory of Open Access Journals (Sweden)

    Emerson Charles M. Silva

    2013-09-01

    Full Text Available This paper presents a proposal for a voltage inverter topology based on push-pull converters, switched at high frequency to inject energy into the grid from a source of DC power. A system using two reverse voltage static converters provides the power grid; energy in the form of alternating current, that can work in conjunction with the provision of utility power. Aiming at the possible use of renewable energy sources, that can be stored in the form of voltage continuous, such as wind, solar, hydroelectric and others. The functioning of topology is presented, such as the power and control circuits, as well as sizing components, theoretical and practical results achieved with the assembly of a prototype 100W of power and switching in 40khz, which after filtering provides the frequency of 60Hz, which is compatible with the Brazilian electrical system.

  2. The Effect of Current-Limiting Reactors on the Tripping of Short Circuits in High-Voltage Electrical Equipment

    International Nuclear Information System (INIS)

    Volkov, M. S.; Gusev, Yu. P.; Monakov, Yu. V.; Cho, Gvan Chun

    2016-01-01

    The insertion of current-limiting reactors into electrical equipment operating at a voltage of 110 and 220 kV produces a change in the parameters of the transient recovery voltages at the contacts of the circuit breakers for disconnecting short circuits, which could be the reason for the increase in the duration of the short circuit, damage to the electrical equipment and losses in the power system. The results of mathematical modeling of the transients, caused by tripping of the short circuit in a reactive electric power transmission line are presented, and data are given on the negative effect of a current-limiting resistor on the rate of increase and peak value of the transient recovery voltages. Methods of ensuring the standard requirements imposed on the parameters of the transient recovery voltages when using current-limiting reactors in the high-voltage electrical equipment of power plants and substations are proposed and analyzed

  3. Dynamic voltage stability constrained congestion management framework for deregulated electricity markets

    International Nuclear Information System (INIS)

    Amjady, Nima; Hakimi, Mahmood

    2012-01-01

    Highlights: ► A new congestion management method for electricity markets is proposed. ► The proposed method includes dynamic models of generators and loads. ► Dynamic voltage stability limits are properly modeled in the proposed method. ► The proposed method is compared with several other congestion management methods. ► It leads to a more robust power system with a lower congestion management cost. - Abstract: Congestion management is an important part of power system operation in today deregulated electricity markets. However, congestion management is traditionally performed based on static analysis tools, while these tools may not correctly capture dynamic voltage stability limits of a power system. In this paper, a new congestion management framework considering dynamic voltage stability boundary of power system is proposed. For this purpose, precise dynamic modeling of power system equipment, including generators and loads, is incorporated into the proposed congestion management framework. The proposed method alleviates congestion with a lower congestion management cost and more dynamic voltage stability margin, resulting in a more robust power system, compared with the previous congestion management methods. The validity of proposed congestion management framework is studied based on the New England 39-bus power system. The obtained results confirm the validity of the developed approach.

  4. Modelling chloride penetration in concrete using electrical voltage and current approaches

    Directory of Open Access Journals (Sweden)

    Juan Lizarazo-Marriaga

    2011-03-01

    Full Text Available This paper reports a research programme aimed at giving a better understanding of the phenomena involved in the chloride penetration in cement-based materials. The general approach used was to solve the Nernst-Planck equation numerically for two physical ideal states that define the possible conditions under which chlorides will move through concrete. These conditions are named in this paper as voltage control and current control. For each condition, experiments and simulations were carried out in order to establish the importance of electrical variables such as voltage and current in modelling chloride transport in concrete. The results of experiments and simulations showed that if those electrical variables are included as key parameters in the modelling of chloride penetration through concrete, a better understanding of this complex phenomenon can be obtained.

  5. The effect of high voltage pulsed electric field on water molecular

    Science.gov (United States)

    Fan, Xuejie; Bai, Yaxiang; Ren, Ziying

    2017-10-01

    In order to study the mechanism of high voltage pulsed electric field pre-treatment on the food drying technology. In this paper, water was treated with high pulse electric field (HPEF) in different frequency, and different voltage, then, the viscosity coefficient and the surface tension coefficient of the water were measured. The results showed that indicated that the viscosity coefficient and the surface tension coefficient of the treated water can be decreased, and while HPEF pre-treatment was applied for 22.5kV at a frequency of 50Hz and 70 Hz, the surface tension and the viscosity coefficient of the pre-treatment treatment were reduced 13.1% and 7.5%, respectively.

  6. Influence Voltage Pulse Electrical Discharge In The Water at the Endurance Fatigue Of Carbon Steel

    OpenAIRE

    I.A. Vakulenko; A.G. Lisnyak

    2016-01-01

    Effect of pulses of electrical discharge in the water at the magnitude of the limited endurance under cyclic loading thermally hardened carbon steel was investigated. Observed increase stamina during cyclic loading a corresponding increase in the number of accumulated dislocations on the fracture surface. Using the equation of Cofino-Manson has revealed a decrease of strain loading cycle after treatment discharges. For field-cycle fatigue as a result of processing the voltage pulses carbon st...

  7. Effect of electric and magnetic fields on current-voltage characteristics of a lyotropic liquid crystal

    International Nuclear Information System (INIS)

    Minasyants, M.Kh.; Badalyan, G. G.; Shahinian, A. A.

    1997-01-01

    The effect of electric and magnetic fields on current-voltage characteristics is studied for the lamellar phase in the lyotropic liquid-crystal sodium pentadecylsulfonate (SPDS)-water and lecithin-water systems. It has been found that the current-voltage characteristics of both systems have hysteresis. In the case of ionogenic SPDS, the hysteresis is formed due to ion current caused by the spatial reorientation of domains consisting of parallel lamellar fragments; in the case of lecithin, whose molecules contain dipoles, the hysteresis is formed due to the spatial reorientation of domains caused by the interaction of the resultant dipole moment of the domains with the electric field. It is shown that the introduction into lamellae of cetylpyridine bromide, which has an intrinsic magnetic moment, changes the resultant magnetic moment of domains and, thus, also the hysteresis loop of the current-voltage characteristic. The systems studied show the 'memory' effect with respect to both the electric and magnetic fields. Field-induced processes of domain reorientation were recorded by the method of small-angle x-ray scattering

  8. Vibration, buckling and smart control of microtubules using piezoelectric nanoshells under electric voltage in thermal environment

    Energy Technology Data Exchange (ETDEWEB)

    Farajpour, A., E-mail: ariobarzan.oderj@gmail.com; Rastgoo, A.; Mohammadi, M.

    2017-03-15

    Piezoelectric nanomaterials such as zinc oxide (ZnO) are of low toxicity and have many biomedical applications including optical imaging, drug delivery, biosensing and harvesting biomechanical energy using hybrid nanogenerators. In this paper, the vibration, buckling and smart control of microtubules (MTs) embedded in an elastic medium in thermal environment using a piezoelectric nanoshell (PNS) are investigated. The MT and PNS are considered to be coupled by a filament network. The PNS is subjected to thermal loads and an external electric voltage which operates to control the mechanical behavior of the MT. Using the nonlocal continuum mechanics, the governing differential equations are derived. An exact solution is presented for simply supported boundary conditions. The differential quadrature method is also used to solve the governing equations for other boundary conditions. A detailed parametric study is conducted to investigate the effects of the elastic constants of surrounding medium and internal filament matrix, scale coefficient, electric voltage, the radius-to-thickness ratio of PNSs and temperature change on the smart control of MTs. It is found that the applied electric voltage can be used as an effective controlling parameter for the vibration and buckling of MTs.

  9. A Review of Neurogenic Stunned Myocardium

    OpenAIRE

    Biso, Sylvia; Wongrakpanich, Supakanya; Agrawal, Akanksha; Yadlapati, Sujani; Kishlyansky, Marina; Figueredo, Vincent

    2017-01-01

    Neurologic stunned myocardium (NSM) is a phenomenon where neurologic events give rise to cardiac abnormalities. Neurologic events like stroke and seizures cause sympathetic storm and autonomic dysregulation that result in myocardial injury. The clinical presentation can involve troponin elevation, left ventricular dysfunction, and ECG changes. These findings are similar to Takotsubo cardiomyopathy and acute coronary syndrome. It is difficult to distinguish NSM from acute coronary syndrome bas...

  10. Electrical treeing behaviors in silicone rubber under an impulse voltage considering high temperature

    Science.gov (United States)

    Yunxiao, ZHANG; Yuanxiang, ZHOU; Ling, ZHANG; Zhen, LIN; Jie, LIU; Zhongliu, ZHOU

    2018-05-01

    In this paper, work was conducted to reveal electrical tree behaviors (initiation and propagation) of silicone rubber (SIR) under an impulse voltage with high temperature. Impulse frequencies ranging from 10 Hz to 1 kHz were applied and the temperature was controlled between 30 °C and 90 °C. Experimental results show that tree initiation voltage decreases with increasing pulse frequency, and the descending amplitude is different in different frequency bands. As the pulse frequency increases, more frequent partial discharges occur in the channel, increasing the tree growth rate and the final shape intensity. As for temperature, the initiation voltage decreases and the tree shape becomes denser as the temperature gets higher. Based on differential scanning calorimetry results, we believe that partial segment relaxation of SIR at high temperature leads to a decrease in the initiation voltage. However, the tree growth rate decreases with increasing temperature. Carbonization deposition in the channel under high temperature was observed under microscope and proven by Raman analysis. Different tree growth models considering tree channel characteristics are proposed. It is believed that increasing the conductivity in the tree channel restrains the partial discharge, holding back the tree growth at high temperature.

  11. Entropy-Based Voltage Fault Diagnosis of Battery Systems for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Peng Liu

    2018-01-01

    Full Text Available The battery is a key component and the major fault source in electric vehicles (EVs. Ensuring power battery safety is of great significance to make the diagnosis more effective and predict the occurrence of faults, for the power battery is one of the core technologies of EVs. This paper proposes a voltage fault diagnosis detection mechanism using entropy theory which is demonstrated in an EV with a multiple-cell battery system during an actual operation situation. The preliminary analysis, after collecting and preprocessing the typical data periods from Operation Service and Management Center for Electric Vehicle (OSMC-EV in Beijing, shows that overvoltage fault for Li-ion batteries cell can be observed from the voltage curves. To further locate abnormal cells and predict faults, an entropy weight method is established to calculate the objective weight, which reduces the subjectivity and improves the reliability. The result clearly identifies the abnormity of cell voltage. The proposed diagnostic model can be used for EV real-time diagnosis without laboratory testing methods. It is more effective than traditional methods based on contrastive analysis.

  12. Analysis and Comparison of Voltage Dependent Charging Strategies for Single-Phase Electric Vehicles in an Unbalanced Danish Distribution Grid

    DEFF Research Database (Denmark)

    Álvarez, Jorge Nájera; Knezovic, Katarina; Marinelli, Mattia

    2016-01-01

    This paper studies four voltage dependent solutions for modulating the charging of multiple Electric Vehicles (EVs) in a real Danish network. Uncontrolled EV charging, especially in grid with high EV penetration, can result in overloaded lines and transformers, low-voltages and other performance...

  13. Voltage tensor for a plasma in high frequency electromagnetic and constant electric fields in the presence of collisions

    International Nuclear Information System (INIS)

    Vigdorchik, N.E.

    1978-01-01

    The voltage tensor expression is obtained for plasma placed in a HF electromagnetic and constant electric fields. The kinetic equations with allowance for collisions are initial. Weakly ionized and completely ionized plasmas are considered. The voltage tensor for completely ionized plasma differs essentially from that for transparent media

  14. High-fidelity optical reporting of neuronal electrical activity with an ultrafast fluorescent voltage sensor

    Science.gov (United States)

    St-Pierre, François; Marshall, Jesse D; Yang, Ying; Gong, Yiyang; Schnitzer, Mark J; Lin, Michael Z

    2015-01-01

    Accurate optical reporting of electrical activity in genetically defined neuronal populations is a long-standing goal in neuroscience. Here we describe Accelerated Sensor of Action Potentials 1 (ASAP1), a novel voltage sensor design in which a circularly permuted green fluorescent protein is inserted within an extracellular loop of a voltage-sensing domain, rendering fluorescence responsive to membrane potential. ASAP1 demonstrates on- and off- kinetics of 2.1 and 2.0 ms, reliably detects single action potentials and subthreshold potential changes, and tracks trains of action potential waveforms up to 200 Hz in single trials. With a favorable combination of brightness, dynamic range, and speed, ASAP1 enables continuous monitoring of membrane potential in neurons at KHz frame rates using standard epifluorescence microscopy. PMID:24755780

  15. Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

    Energy Technology Data Exchange (ETDEWEB)

    Londer, Ya. I.; Ul’yanov, K. N., E-mail: kulyanov@vei.ru [Lenin All-Russian Electrotechnical Institute (Russian Federation)

    2013-10-15

    The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v{sub 0} to their thermal velocity v{sub T}. It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v{sub 0}/v{sub T}, the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v{sub i}(0), and ratio v{sub 0}/v{sub T} at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v{sub i}{sup *}(0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v{sub i}{sup *} (0) on ρ(0), E(0), and v{sub 0}/v{sub T} determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge.

  16. Degradation diagnosing method for low voltage electric wire and cable in nuclear facility

    International Nuclear Information System (INIS)

    Kamimura, Seiji; Seki, Ikuo; Yagyu, Hideki; Onishi, Takao; Kusama, Yasuo.

    1991-01-01

    A considerable skill is required for a visual inspection method which has been used most widely for determining the degradation of low voltage electric wires and cables used mostly in facilities such as nuclear power plants. It is extremely difficult to determine the degradation accurately and appropriately even for skilled inspectors because of individual difference. Then, a small amount of organic insulation materials is taken as a sample from insulators or sheath materials actually disposed. The pyrolytic temperature of the sample is measured by thermal gravimetric analysis to determine the extent of the degradation of the electric wire and cable based on the relationship between the degradation and the elongation. Since there is a close relationship between the temperature at which the measured weight of the sample is reduced by 5% and the degradation behavior of the mechanical property, analysis can be conducted effectively by an extremely small amount of the sample. Since the insulation degradation of relatively low voltage electric wires and cables can be determined in a non-destructive manner at high accuracy, the lifetime can be forecasted. (N.H.)

  17. Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

    International Nuclear Information System (INIS)

    Londer, Ya. I.; Ul’yanov, K. N.

    2013-01-01

    The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v 0 to their thermal velocity v T . It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v 0 /v T , the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v i (0), and ratio v 0 /v T at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v i * (0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v i * (0) on ρ(0), E(0), and v 0 /v T determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge

  18. Impact and Cost Evaluation of Electric Vehicle Integration on Medium Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cheng, Lin; Pineau, Ulysse

    2013-01-01

    This paper presents the analysis of the impact of electric vehicle (EV) integration on medium voltage (MV) distribution networks and the cost evaluation of replacing the overloaded grid components. A number of EV charging scenarios have been studied. A 10 kV grid from the Bornholm Island...... in the city area has been used to carry out case studies. The case study results show that the secondary transformers are the bottleneck of the MV distribution networks and the increase of EV penetration leads to the overloading of secondary transformers. The cost of the transformer replacement has been...

  19. Influence of gas stunning and halal slaughter (no stunning) on rabbits welfare indicators and meat quality.

    Science.gov (United States)

    Nakyinsige, K; Sazili, A Q; Zulkifli, I; Goh, Y M; Abu Bakar, F; Sabow, A B

    2014-12-01

    This study assessed the effect of gas stunning which has not been conducted until now in comparison with slaughter without stunning on the welfare and meat quality of rabbits. Eighty male New Zealand White rabbits were divided into two groups of 40 animals and subjected to either halal slaughter without stunning (HS) or gas stunning using 61.4% CO2, 20.3% oxygen and 18.3 % nitrogen (GS). Analysis of the sticking blood revealed that both slaughter procedures caused a substantial increase in the levels of catecholamines, hypercalcemia, hyperglycemia, lactic acidemia and an increase in enzyme activities. The ultimate pH of the Longissimus lumborum muscle did not differ between treatments. GS exhibited higher lightness and cooking loss, and lower glycogen and MFI than HS. This indicates that both GS and HS can be significant stressors although the amount of stress may be below the threshold to negatively affect rabbit meat quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Simulations of momentum transfer process between solar wind plasma and bias voltage tethers of electric sail thruster

    Science.gov (United States)

    Xia, Guangqing; Han, Yajie; Chen, Liuwei; Wei, Yanming; Yu, Yang; Chen, Maolin

    2018-06-01

    The interaction between the solar wind plasma and the bias voltage of long tethers is the basic mechanism of the electric sail thruster. The momentum transfer process between the solar wind plasma and electric tethers was investigated using a 2D full particle PIC method. The coupled electric field distribution and deflected ion trajectory under different bias voltages were compared, and the influence of bias voltage on momentum transfer process was analyzed. The results show that the high potential of the bias voltage of long tethers will slow down, stagnate, reflect and deflect a large number of ions, so that ion cavities are formed in the vicinity of the tether, and the ions will transmit the axial momentum to the sail tethers to produce the thrust. Compared to the singe tether, double tethers show a better thrust performance.

  1. Quadratic dependence of the spin-induced Hall voltage on longitudinal electric field

    International Nuclear Information System (INIS)

    Miah, M. Idrish

    2008-01-01

    The effect of optically induced spins in semiconductors in the low electric field is investigated. Here we report an experiment which investigates the effect of a longitudinal electric field (E) on the spin-polarized carriers generated by a circularly polarized light in semiconductors. Our experiment observes the effect as a spin-induced anomalous Hall voltage (V AH ) resulting from spin-carrier electrons accumulating at the transverse edges of the sample. Unlike the ordinary Hall effect, a quadratic dependence of V AH on E is observed, which agrees with the results of the recent theoretical investigations. It is also found that V AH depends on the doping density. The results are discussed

  2. Quadratic dependence of the spin-induced Hall voltage on longitudinal electric field

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M. Idrish [Nanoscale Science and Technology Centre, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); School of Biomolecular and Physical Sciences, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); Department of Physics, University of Chittagong, Chittagong 4331 (Bangladesh)], E-mail: m.miah@griffith.edu.au

    2008-10-15

    The effect of optically induced spins in semiconductors in the low electric field is investigated. Here we report an experiment which investigates the effect of a longitudinal electric field (E) on the spin-polarized carriers generated by a circularly polarized light in semiconductors. Our experiment observes the effect as a spin-induced anomalous Hall voltage (V{sub AH}) resulting from spin-carrier electrons accumulating at the transverse edges of the sample. Unlike the ordinary Hall effect, a quadratic dependence of V{sub AH} on E is observed, which agrees with the results of the recent theoretical investigations. It is also found that V{sub AH} depends on the doping density. The results are discussed.

  3. Electric power quality analysis methods. Application to voltage dips and harmonic disturbances

    International Nuclear Information System (INIS)

    Vanya, Ignatova

    2006-10-01

    The power quality concerns all the actors in the energy domains, that they are network administrators, suppliers, producers, or consumers of electricity. The research work presented in this PhD thesis is situated in the field of the power quality monitoring. Its objective is to introduce new techniques for analysis of power quality problems. There are different methods designed for the analysis of the power quality disturbances. This method reaches very good performances in the voltage dips analysis, as it allows segmenting, classifying and characterising these power quality disturbances. The periodic systems method allows the theoretical study of the generation and the propagation of harmonic disturbances in the network. Finally, the statistical matrix method has the objective to represent statistically electrical signals without loss of important information. (author)

  4. Important parameters affecting the cell voltage of aqueous electrical double-layer capacitors

    Science.gov (United States)

    Wu, Tzu-Ho; Hsu, Chun-Tsung; Hu, Chi-Chang; Hardwick, Laurence J.

    2013-11-01

    This study discusses and demonstrates how the open-circuit potential and charges stored in the working potential window on positive and negative electrodes affect the cell voltage of carbon-based electrical double-layer capacitors (EDLCs) in aqueous electrolytes. An EDLC consisting of two activated carbon electrodes is employed as the model system for identifying these key parameters although the potential window of water decomposition can be simply determined by voltammetric methods. First, the capacitive performances of an EDLC with the same charge on positive and negative electrodes are evaluated by cyclic voltammetric, charge-discharge, electrochemical impedance spectroscopic (EIS) analyses, and inductance-capacitance-resistance meter (LCR meter). The principles for obtaining the highest acceptable cell voltage of such symmetric ECs with excellent reversibility and capacitor-like behaviour are proposed. Aqueous charge-balanced EDLCs can be operated as high as 2.0 V with high energy efficiency (about 90%) and only 4% capacitance loss after the 600-cycle stability checking. The necessity of charge balance (but not capacitance balance) for positive and negative electrodes is substantiated from the lower acceptable cell voltage of charge-unbalanced EDLCs.

  5. Avaliação de diferentes híbridos suínos submetidos à insensibilização elétrica e gasosa (CO2: parte 2 - mensurações objetivas de qualidade Evaluation of different swine breeds submitted to the electric and gaseous(CO2 stunning systems: part 2 - quality objective mensurations

    Directory of Open Access Journals (Sweden)

    William Bertoloni

    2006-06-01

    Full Text Available Suínos provenientes de três linhagens genética (A, B e C comercializados no Brasil, com peso vivo de 100 a 120 kg foram submetidos ao insensibilizador elétrico manual (Karl Schermer 220-230/250 volts, 45-60 Hz e 1,4-1,5A e ao gasoso coletivo (Combi-Butina 90% CO2 no mesmo abatedouro. O sistema gasoso proporcionou aos híbridos valores (b* superiores (pPigs of three genetic lineages A, B and C commercialized in Brazil, with weight from 100 to 120 kg, were submitted to the manual electric stunning (Karl Schermer 220-230/250 Volts, 45-60 Hz and 1,4 -1,5A and to the collective gaseous system (COMBI-BUTINA 90% CO2 at the same slaughterhouse. The gaseous system provided to the hybrids an increase in the values (b* (p<0,001, when compared to the electric system, as well as differences in the average values of light scattering (Hennessy-gp4 to the 45 min. pm and 24ª h pm (p<0,05. When submitted to the gaseous system, differences among the hybrid in the average values of superficial brightness (L 24ª h pm (p<0,0001 pH 24ª h pm (SM (p<0,0001, values (b* 24ª h pm (p<0,05, light scattering 45 min e 24ª h (LD (p<0,001 were observed. By using the manual electric system, significant differences were verified in the average values of light scattering (LD 45 min. e 24ª h pm (p<0,001, as well as in the average values of pH 24ª h pm (SM e (SC (p<0,05. However, the differences obtained between the stunning systems and hybrids were not enough to provide significant differences in the values of water holding capacity, drip loss and expressible moisture.

  6. [Influence of high-voltage electric burn on the microcirculation of heart in rabbit].

    Science.gov (United States)

    Zhang, Qing-fu; Zhou, Hui-min; Wang, Che-jiang; Shao, Hong-bo

    2012-06-01

    To study the influence of high-voltage electric burn on the microcirculation of heart in rabbit. One-hundred and twenty New Zealand rabbits of clean grade were divided into control group (C) and electric burn group (EB) according to the random number table, with 60 rabbits in each group. Rabbits in EB group were subjected to high-voltage electric burn (the electrical current flow into the left foreleg at the lateral side of proximal end and out from the corresponding site of the right hind leg) with voltage regulator and experimental transformer. Rabbits in C group were sham injured with the same devices without electrification. At 15 minutes before injury, and 5 minutes, 1, 2, 4, 8 hour (s) post injury (PIM or PIH), ten rabbits in each group were chosen to examine the cardiac apex microcirculation hemoperfusion (CAMH) with laser Doppler hemoperfusion image instrument. The morphologic changes of microvessels of left ventricular wall tissues of 2 rabbits from each of the 10 rabbits collected at above-mentioned time points were observed with light microscope and transmission electron microscope. Auricular vein blood of rabbit was harvested at above-mentioned time points for the determination of aspartate amino transferase (AST), lactate dehydrogenase (LDH), hydroxybutyrate dehydrogenase (HBDH), creatine kinase (CK), and creatine kinase isozyme MB (CK-MB) by full-automatic biochemical analyzer. Data were processed with two-factor analysis of variance and LSD test. (1) The differences between C group and EB group in detection results were statistically significant, with F values from 425.991 to 3046.834, P values all below 0.01. Only the data within EB group were comparable. (2) At PIM 5, the CAMH value of rabbits in EB group was (1.96 ± 0.09) V, which was lower than that at 15 minutes before injury [(4.34 ± 0.35) V, P electric burn can bring damage to the microvessels of heart in rabbits and change blood flow of microcirculation, which should be given adequate

  7. Decentralized energy management strategy based on predictive controllers for a medium voltage direct current photovoltaic electric vehicle charging station

    International Nuclear Information System (INIS)

    Torreglosa, Juan P.; García-Triviño, Pablo; Fernández-Ramirez, Luis M.; Jurado, Francisco

    2016-01-01

    Highlights: • Electric vehicle charging station supplied by photovoltaic, batteries and grid connection is analyzed. • The bus voltage is the key parameter for controlling the system by decentralized approach. • Decentralized control approach facilities the enlargement of the system. • Photovoltaic and battery systems are controlled by model predictive controllers. • Response by model predictive controllers improves that by PI controllers. - Abstract: The use of distributed charging stations based on renewable energy sources for electric vehicles has increased in recent years. Combining photovoltaic solar energy and batteries as energy storage system, directly tied into a medium voltage direct current bus, and with the grid support, results to be an interesting option for improving the operation and efficiency of electric vehicle charging stations. In this paper, an electric vehicle charging station supplied by photovoltaic solar panels, batteries and with grid connection is analysed and evaluated. A decentralized energy management system is developed for regulating the energy flow among the photovoltaic system, the battery and the grid in order to achieve the efficient charging of electric vehicles. The medium voltage direct current bus voltage is the key parameter for controlling the system. The battery is controlled by a model predictive controller in order to keep the bus voltage at its reference value. Depending on the state-of-charge of the battery and the bus voltage, the photovoltaic system can work at maximum power point tracking mode or at bus voltage sustaining mode, or even the grid support can be needed. The results demonstrate the proper operation and energy management of the electric vehicle charging station under study.

  8. Illumination and Voltage Dependence of Electrical Characteristics of Au/0.03 Graphene-Doped PVA/n-Si Structures via Capacitance/Conductance-Voltage Measurements

    International Nuclear Information System (INIS)

    Sahar, Alialy; Şlemsettin, Altındal; Ahmet, Kaya; İ, Uslu

    2015-01-01

    Au/n-Si (MS) structures with a high dielectric interlayer (0.03 graphene-doped PVA) are fabricated to investigate the illumination and voltage effects on electrical and dielectric properties by using capacitance-voltage (C-V) and conductance-voltage (G/ω-V) measurements at room temperature and at 1 MHz. Some of the main electrical parameters such as concentration of doping atoms (N D ), barrier height (ϕ B (C - V)), depletion layer width (W D ) and series resistance (R s ) show fairly large illumination dispersion. The voltage-dependent profile of surface states (N ss ) and resistance of the structure (R i ) are also obtained by using the dark-illumination capacitance (C dark -C ill ) and Nicollian-Brews methods, respectively. For a clear observation of changes in electrical parameters with illumination, the values of N D , W D , ϕ B (C - V) and R s are drawn as a function of illumination intensity. The values of N D and W D change almost linearly with illumination intensity. On the other hand, R s decreases almost exponentially with increasing illumination intensity whereas ϕ B (C - V) increases. The experimental results suggest that the use of a high dielectric interlayer (0.03 graphene-doped PVA) considerably passivates or reduces the magnitude of the surface states. The large change or dispersion in main electrical parameters can be attributed to generation of electron-hole pairs in the junction under illumination and to a good light absorption. All of these experimental results confirm that the fabricated Au/0.03 graphene-doped PVA/n-Si structure can be used as a photodiode or a capacitor in optoelectronic applications. (paper)

  9. PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE

    Directory of Open Access Journals (Sweden)

    V. G. Zhekul

    2017-10-01

    Full Text Available Purpose. Investigations of the characteristics of pressure waves presuppose the registration of the total profile of the pressure wave at a given point in space. For these purposes, various types of «pressure to the electrical signal» transmitters (sensors are used. Most of the common sensors are unsuitable for measuring the pulse pressure in a closed water volume at high hydrostatic pressures, in particular to study the effect of a powerful high-voltage pulse discharge on increasing the inflow of minerals and drinking water in wells. The purpose of the work was to develop antijamming piezoelectric waveguide sensor for measuring pulse pressure at a close distance from a high-voltage discharge channel in a closed volume of a liquid. Methodology. We have applied the calibration method as used as a secondary standard, the theory of electrical circuits. Results. We have selected the design and the circuit solution of the waveguide pressure sensor. We have developed a waveguide pulse-pressure sensor DTX-1 with a measuring loop. This sensor makes it possible to study the spectral characteristics of pressure waves of high-voltage pulse discharge in closed volumes of liquid at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C. The sensor can be used to study pressure waves with a maximum amplitude value of up to 150 MPa and duration of up to 80 µs. According to the results of the calibration, the sensitivity of the developed sensor DTX-1 with a measuring loop is 0.0346 V/MPa. Originality. We have further developed the theory of designing the waveguide piezoelectric pulse pressure sensors for measuring the pulse pressure at a close distance from a high-voltage discharge channel in a closed fluid volume by controlling the attenuation of the amplitude of the pressure signal. Practical value. We have developed, created, calibrated, used in scientific research waveguide pressure pulse sensors DTX-1. We propose sensors DTX-1 for sale

  10. Control of Active Front-End Rectifier in Electric Drive under Unbalanced Voltage Supply in Transient States

    Czech Academy of Sciences Publication Activity Database

    Chomát, Miroslav; Schreier, Luděk; Bendl, Jiří

    2012-01-01

    Roč. 88, 1A (2012), s. 177-180 ISSN 0033-2097 R&D Projects: GA ČR GA102/09/1273 Institutional research plan: CEZ:AV0Z20570509 Keywords : unbalanced voltage supply * DC-link voltage pulsations * pulse-width modulation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.244, year: 2011 http://www.red.pe.org.pl/abstract_pl.php?nid=5479

  11. Electric Arc Furnace Modeling with Artificial Neural Networks and Arc Length with Variable Voltage Gradient

    Directory of Open Access Journals (Sweden)

    Raul Garcia-Segura

    2017-09-01

    Full Text Available Electric arc furnaces (EAFs contribute to almost one third of the global steel production. Arc furnaces use a large amount of electrical energy to process scrap or reduced iron and are relevant to study because small improvements in their efficiency account for significant energy savings. Optimal controllers need to be designed and proposed to enhance both process performance and energy consumption. Due to the random and chaotic nature of the electric arcs, neural networks and other soft computing techniques have been used for modeling EAFs. This study proposes a methodology for modeling EAFs that considers the time varying arc length as a relevant input parameter to the arc furnace model. Based on actual voltages and current measurements taken from an arc furnace, it was possible to estimate an arc length suitable for modeling the arc furnace using neural networks. The obtained results show that the model reproduces not only the stable arc conditions but also the unstable arc conditions, which are difficult to identify in a real heat process. The presented model can be applied for the development and testing of control systems to improve furnace energy efficiency and productivity.

  12. Investigation of voltages and electric fields in silicon semi 3D radiation detectors using Silvaco/ATLAS simulation tool and a scanning electron microscope

    CERN Document Server

    Palviainen, T; Tuuva, T; Eranen, S; Härkönen, J; Luukka, P; Tuovinen, E

    2006-01-01

    The structure of silicon semi three-dimensional radiation detector is simulated on purpose to find out its electrical characteristics such as the depletion voltage and electric field. Two-dimensional simulation results are compared to voltage and electric field measurements done by a scanning electron microscope.

  13. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator

    International Nuclear Information System (INIS)

    Nolot, E.

    1996-01-01

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF 6 . This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF 6 . In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author)

  14. Effect of voltage shape of electrical power supply on radiation and density of a cold atmospheric argon plasma jet

    Directory of Open Access Journals (Sweden)

    F Sohbatzadeh

    2017-02-01

    Full Text Available In this work, we investigated generating argon cold plasma jet at atmospheric pressure based on dielectric barrier discharge configuration using three electrical power supplies of sinusoidal, pulsed and saw tooth high voltage shapes at 8 KHZ. At first; we describe the electronic circuit features for generating high voltage (HV wave forms including saw tooth, sinusoidal and pulsed forms. Then, we consider the effect of voltage shape on the electrical breakdown. Relative concentrations of chemical reactive species such as Oxygen, atomic Nitrogen and OH were measured using optical emission spectroscopy. Using a simple numerical model, we showed a HV with less rise time increases electron density, therefore a cold plasma jet can be produced with a minimal consumption electrical power

  15. Evaluation of the contact switch materials in high voltage power supply for generate of underwater shockwave by electrical discharge

    Directory of Open Access Journals (Sweden)

    K Higa

    2016-10-01

    Full Text Available We have developed the high voltage power-supply unit by Cockcroft-Walton circuit for ingenerate high pressure due to underwater shockwave by electrical discharge. This high voltage power supply has the problem of the metal contact switch operation that contact switch stop by melting and bonding due to electrical spark. We have studied the evaluation of materials of contact switch for the reducing electrical energy loss and the problem of contact switch operation. In this research, measurement of discharge voltage and high pressure due to underwater shockwave was carried out using the contact switch made of different materials as brass plate, brass-carbon plate-brass and carbon block. The contact switch made of carbon is effective to reduce energy loss and problem of contactor switch operation.

  16. Pyogenic Arthritis of the Ankle Joint Following a High-Voltage Electrical Burn in the Lower Extremity: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kuk Seon; Lee, Gyung Kyu; Kang, Ik Won; Hwang, Dae Hyun; Lee, Eil Seong; Min, Seon Jung; Han, You Mie [Dept. of Radiology, Hangang Scared Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Lee, Eil Seong [Dept.of Radiology, Gyeongju Hospital, Dongguk University College of Medicine, Gyeongju (Korea, Republic of)

    2011-04-15

    A high-voltage electrical burn caused extensive deep muscle injuries beneath a relatively small skin wound at the contact point. Hidden, undetected deep muscle injuries have a tendency for progressive tissue necrosis, which can lead to major amputations or sepsis. The radiologic features of this rare, sometimes life-threatening injury have occasionally been described in the literature. However, to the best of our knowledge, there have been no reports on a case of pyogenic arthritis of the ankle joint following a high-voltage electrical burn involving the lower extremity. We report a case of the pyogenic arthritis of the ankle joint following a high-voltage electrical burn involving the lower extremity.

  17. A Review of Neurogenic Stunned Myocardium

    Science.gov (United States)

    Wongrakpanich, Supakanya; Agrawal, Akanksha; Yadlapati, Sujani; Kishlyansky, Marina; Figueredo, Vincent

    2017-01-01

    Neurologic stunned myocardium (NSM) is a phenomenon where neurologic events give rise to cardiac abnormalities. Neurologic events like stroke and seizures cause sympathetic storm and autonomic dysregulation that result in myocardial injury. The clinical presentation can involve troponin elevation, left ventricular dysfunction, and ECG changes. These findings are similar to Takotsubo cardiomyopathy and acute coronary syndrome. It is difficult to distinguish NSM from acute coronary syndrome based on clinical presentation alone. Because of this difficulty, a patient with NSM who is at high risk for coronary heart disease may undergo cardiac catheterization to rule out coronary artery disease. The objective of this review of literature is to enhance physician's awareness of NSM and its features to help tailor management according to the patient's clinical profile. PMID:28875040

  18. Neurogenic stunned myocardium following hemorrhagic cerebral contusion

    International Nuclear Information System (INIS)

    Deleu, D.; Miyares, F.; Kettern, M.; Kumar, S.; Hassens, Y.; Salim, K.

    2007-01-01

    Neurogenic stunned myocardium NSM is a well-known complication of subarachnoidal hemorrhage, but has been reported rarely in association with other central nervous system disorders. A case of NSM is described in a patient with hemorrhagic brain contusion associated with cerebral edema. An 18-year-old man was admitted with severe cranial trauma following a car roll-over. Six days after admission, he developed findings suggestive for NSM. The troponin T and creatine kinase-MB level were elevated and echocardiogram showed apical and inferoposterior hypokinesis and diffuse left ventricular akinesis with severely reduced ejection fraction 18%. Invasive measurements confirmed low cardiac output. His cardiac function resolved completely within 6 days after decompressive craniotomy. This case supports the presumed unifying role of the increased intracranial pressure, probably triggering a vigorous sympathetic outflow hyperactivity leading to NSM. (author)

  19. Fire extinguishing of electrical equipment under voltage at nuclear power plants

    International Nuclear Information System (INIS)

    Capek, Josef

    2009-01-01

    Fire extinguishing on equipment that is under voltage is always hazardous. Conventional fire fighting equipment applicable to this task includes powder and gas extinguishers, which, however, have some drawbacks. Therefore, attention has been increasingly devoted to high-pressure fire extinguishing, whose assets include better heat removal as compared to a full water flow where the majority of the water runs off without any cooling effect. This article describes the testing of some types and combinations of extinguishing techniques and their interpretation based on earth-leakage current measurement and determination of a safe distance for fire extinguishing. Methodology described in CSN IEC 60-1:1994 and CSN EN 3-7:2004 was applied. To meet the criterion, none of the tests was to exhibit an earth-leakage current higher than 0.5 mA. In the accredited laboratory test room setup, 3 extinguishing equipment arrangements proved to extinguish fire on electrical equipment under voltage at a safe distance of 1 m (or 3 m). (orig.)

  20. Security cost analysis in electricity markets based on voltage security criteria and Web-based implementation

    International Nuclear Information System (INIS)

    Chen, H.

    2003-01-01

    This paper presents an efficient and transparent method for electricity market operators to analyze transaction security costs and to quantify the correlation between market operation and power system operation. Rescheduling and take-risk strategies were proposed and discussed with reference to transaction impact computations, thermal and voltage limits and voltage stability criteria. The rescheduling method is associated with an iterative generation dispatch or load curtailment approach to minimize the amount of rescheduling. The take-risk method considered operating risks to facilitate transactions. The SATC concept was also proposed to accurately evaluate transmission congestion. The impact of transaction was calculated using a new sensitivity formula to find the most effective rescheduling direction and the most effective cost distribution. A new pricing method called Nodal Congestion Price was also proposed to determine proper price signals. The paper also presents an Artificial Neural Network (ANN) based short term load forecasting method that considers the effect of price on the load. A web-based prototype was implemented to allow all market participants access to the proposed analysis and pricing techniques. Several case studies have validated the effectiveness of the proposed method which would help independent system operators in determining congestion prices, coordinate transactions and make profitable market decisions

  1. Extension of the Accurate Voltage-Sag Fault Location Method in Electrical Power Distribution Systems

    Directory of Open Access Journals (Sweden)

    Youssef Menchafou

    2016-03-01

    Full Text Available Accurate Fault location in an Electric Power Distribution System (EPDS is important in maintaining system reliability. Several methods have been proposed in the past. However, the performances of these methods either show to be inefficient or are a function of the fault type (Fault Classification, because they require the use of an appropriate algorithm for each fault type. In contrast to traditional approaches, an accurate impedance-based Fault Location (FL method is presented in this paper. It is based on the voltage-sag calculation between two measurement points chosen carefully from the available strategic measurement points of the line, network topology and current measurements at substation. The effectiveness and the accuracy of the proposed technique are demonstrated for different fault types using a radial power flow system. The test results are achieved from the numerical simulation using the data of a distribution line recognized in the literature.

  2. Thin grain oriented electrical steel for PWM voltages fed magnetic cores

    Directory of Open Access Journals (Sweden)

    Thierry Belgrand

    2018-04-01

    Full Text Available This paper reports on performances of high permeability grain oriented electrical steel when used in association with power electronic switching devices. Loss measurement results obtained from the Epstein test, using sinusoidal or various PWM voltages in medium frequency range, show that for both studied thicknesses (HGO 0.23mm and HGO 0.18mm, comparing performances at a fixed induction level between the various situations may not be the most convenient method. The effect of magnetic domain refinement has been investigated. After having shown the interest of lowering the thickness, an alternative way of looking at losses is proposed that may help to design the magnetic core when it comes to the matter of reducing size in considering frequency and magnetization levels.

  3. Study on condition monitoring techniques for low voltage electrical cables in nuclear power plants

    International Nuclear Information System (INIS)

    Hirao, Hideo; Sakai, Takeshi; Kajimura, Yuusaku

    2017-01-01

    Low voltage electrical cables installed in nuclear power plants are required to maintain its function in a design basis accident environment and they are qualified to that environment. The cables degrade also in normal operating conditions due to ageing and they must maintain integrity until the end of their qualified life. Demands for the condition monitoring technique for low voltage electrical cables have therefore been increasing as nuclear power plants operate longer. A single perfect method for this purpose is not available yet, but the possibility to use two different types of methods which can complement with each other has been examined. The combination of Fourier Transform Infrared Spectroscopy (FT-IR) and Indenter Modulus (IM) method was found highly effective. FT-IR is a method that determines chemical properties (changes in molecular bindings) of cables by using infrared rays, while IM is a method that determines mechanical properties (changes in hardness) of cables by indenters. Both methods are non-destructive and can be applied in-situ to the same material. Reliability of the evaluation can be assured by applying two different types of measurement principles that complement with each other. In this study, various cable samples with different kinds of insulation material (cross-linked polyethylene, ethylene propylene rubber, silicone rubber etc.) were aged with a special accelerated ageing technique which applies simultaneous thermal and radiation ageing to simulate ageing phenomena in a more realistic manner, and the degree of ageing was evaluated with FT-IR and IM. The evaluation result shows good correlation with ageing time and other ageing properties for most material types and the effectiveness of these methods were demonstrated. (author)

  4. [Dynamic change in microcirculation of pancreas after experimental high-voltage electric burn].

    Science.gov (United States)

    Zhang, Qing-fu; Bai, Yong-qiang

    2009-10-01

    To observe the changes in surface microcirculation of pancreas after high-voltage electric burn (HEB). Thirty rabbits were divided into electrical injury (E) group and control (C) group in a simple random method, with 15 rabbits in each group. Rabbit model of HEB was reproduced from E group with TC-30-20KVA type voltage regulator and YDJ-10KVA type experimental transformer. Rabbits in C group were shamly burned with the same equipment as in E group but not electrified. Intravenous blood of rabbits in both groups was drawn 15 mins before HEB and 0, 1, 2, 4, 8 h after to determine the levels of serum amylase and blood glucose. The morphology of the pancreas microvessels and its surrounding tissues, and the dynamic changes in microvascular blood flow were observed with WX-9 microscope and its image analytical system. The level of serum amylase of rabbits in E group increased gradually and peaked (849 +/- 39) U/L at 8 post HEB h (PHH), which decreased gradually reaching the nadir (153 +/- 21) U/L at 8 PHH in C group (P 0.05), and no erythrocyte aggregation or microthrombus was found in both groups. In E group, blood flow speed slowed down at 0 PHH as compared with that before HEB, it accelerated at 1 h and slowed down later; erythrocyte aggregation in venules and capillaries was found at 0 PHH, and it aggregated gradually. No above-mentioned change was found in C group. HEB produces microcirculation disturbance and functional disturbance of pancreas.

  5. Technical challenges for electric power industries due to grid-integrated electric vehicles in low voltage distributions: A review

    International Nuclear Information System (INIS)

    Haidar, Ahmed M.A.; Muttaqi, Kashem M.; Sutanto, Danny

    2014-01-01

    Highlights: • Grid-Integrated Vehicles (GIVs) as mobile storage systems are briefly discussed. • Comparative analysis on electric vehicles (EVs) and charging systems are provided. • It is necessary to coordinate the GIVs to minimize its impacts on power grid. • A proper load model of EVs that predicts the realistic system behavior is required. • Offering a dual tariff by grid utilities is needed as a way to reduce peak load. - Abstract: Grid-Integrated Vehicles (GIVs) are promising technologies for future Smart Grid (SG) and offer the potential to reduce the environmental impact of vehicles. The large scale deployment of GIVs without proper control of the time to charge the vehicles can result in unexpected challenges. This can lead to a disruptive impact on the current power distribution systems and in particular its substantial impacts in building power energy systems. Therefore, a proper model that predicts the realistic system behavior is required to analysis the true effects of introducing GIVs in the power grid. This paper presents a review of existing studies on GIV systems, their modeling techniques and their effects on power grids. Following a brief overview of the common types of electric vehicles (EVs) with their charging systems, a review of their impact on the low voltage distribution systems will be analyzed. The comprehensive review presented in this paper reveals that the impact of GIVs on power distribution systems can be quantified using the aspects of EVs, such as vehicle penetration, charging time, charging characteristics, driving patterns, transportation network. GIV studies are expected to be more popular in future years with the development of EV technologies and the government support to electricity utilities. Thereby, these factors will reduce the cost of energy to charge EV and enhance the practical implications of GIVs

  6. Impact of Distribution Feeders that do not have Voltage Regulators on the number of Charged Electric Vehicles using IEEE 34 Bus Test Feeder

    Energy Technology Data Exchange (ETDEWEB)

    Allehyani, Ahmed [University of Southern California, Department of Electrical Engineering; Beshir, Mohammed [University of Southern California, Department of Electrical Engineering

    2015-02-01

    Voltage regulators help maintain an acceptable voltage profile for the system. This paper discusses the effect of installing voltage regulators to the system to fix the voltage drop resulting from the electrical vehicles loading increase when they are being charged. The effect will be studied in the afternoon, when the peak load occurs, using the IEEE 34 bus test feeder. First, only one spot node is used to charge the electric vehicles while a voltage regulator is present. Second, five spot nodes are loaded at the same time to charge the electric vehicles while voltage regulators are installed at each node. After that, the impact of electric vehicles on distribution feeders that do not have voltage regulators will appear.

  7. Continuous extraction of phenolic compounds from pomegranate peel using high voltage electrical discharge.

    Science.gov (United States)

    Xi, Jun; He, Lang; Yan, Liang-Gong

    2017-09-01

    Pomegranate peel, a waste generated from fruit processing industry, is a potential source of phenolic compounds that are known for their anti-oxidative properties. In this study, a continuous high voltage electrical discharge (HVED) extraction system was for the first time designed and optimized for phenolic compounds from pomegranate peel. The optimal conditions for HVED were: flow rate of materials 12mL/min, electrodes gap distance 3.1mm (corresponding to 29kV/cm of electric field intensity) and liquid to solid ratio 35mL/g. Under these conditions, the experimental yield of phenolic compounds was 196.7±6.4mg/g, which closely agreed with the predicted value (199.83mg/g). Compared with the warm water maceration, HVED method possessed higher efficiency for the extraction of phenolic compounds. The results demonstrated that HVED technique could be a very effective method for continuous extraction of natural compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Modeling Of Components Of A Photovoltaic System With Voltage Inverter For Connection To The Electrical Grid

    International Nuclear Information System (INIS)

    Ferreira, Andreza C.; Blasques, Luis C. M.; Galhardo, Marcos A. B.; Pinho, João T.

    2017-01-01

    This paper describes the modeling of the electrical equipment and control mechanisms used in the power conditioning system of a grid-connected photovoltaic system (GCPVS), such as the photovoltaic generator, the DC/DC converter, the voltage inverter with PWM control, its output filter, as well as the converter controls and their functionalities, and the interconnection of the system with the distribution grid and load. In addition to the modeling of the grid-tie inverter, the main equipment of the power conditioning system, this paper describes the synchronization form of the photovoltaic (PV) generation with the electricity distribution grid, considering the power injection control method, the maximum power point tracking technique for maximizing the energy supplied by the photovoltaic generator, and the complete topology of the proposed PV system. The main objective is to provide a computational model capable of simulating the behavior of the GCPVS elements, varying the climatic conditions and the power demand on the AC side, presenting consistent results for different operating conditions, such as variations of climatic parameters (solar irradiance, wind speed, and ambient temperature) and load. In these cases, it is possible to evaluate the behavior of the system, sometimes supplying both the active and reactive power of the load, according to the need. (author)

  9. Modelling and Simulation of the SVC for Power System Flow Studies: Electrical Network in voltage drop

    Directory of Open Access Journals (Sweden)

    Narimen Aouzellag LAHAÇANI

    2008-12-01

    Full Text Available The goal of any Flexible AC Transmission Systems (FACTS devices study is to measure their impact on the state of the electrical networks into which they are introduced. Their principal function is to improve the static and dynamic properties of the electrical networks and that by increasing the margins of static and dynamic stability and to allow the power transit to the thermal limits of the lines.To study this impact, it is necessary to establish the state of the network (bus voltages and angles, powers injected and forwarded in the lines before and after the introduction of FACTS devices. This brings to calculate the powers transit by using an iterative method such as Newton-Raphson. Undertaking a calculation without the introduction of FACTS devices followed by a calculation with the modifications induced by the integration of FACTS devices into the network, makes it possible to compare the results obtained in both cases and thus assess the interest of the use of devices FACTS.

  10. Effect of Transportation and Low Voltage Electrical Stimulation on Meat Quality Characteristics of Omani Sheep

    Directory of Open Access Journals (Sweden)

    Isam T. Kadim

    2010-01-01

    Full Text Available The aim of this study was to determine the effects of road transportation during the hot season (36 oC and low voltage electrical stimulation on meat quality characteristics of Omani sheep. Twenty intact male sheep (1-year old were divided into two equal groups: 3 hrs transported or non-transported. The transported group was transferred to the slaughterhouse the day of slaughter in an open truck covering a distance of approximately 300 km. The non-transported group was kept in a lairage of a commercial slaughterhouse with ad libitum feed and water for 3 days prior to slaughter. Blood samples were collected from the animals before loading and prior to slaughter in order to assess their physiological response to stress in terms of hormonal levels. Fifty percent of the carcasses from each group were randomly assigned to low voltage (90 V at 20 min postmortem. Muscle ultimate pH, expressed juice, cooking loss percentage, WB-shear force value, sarcomere length, myofibrillar fragmentation index and colour L*, a*, b* were measured on samples from Longissimus dorsi muscles collected 24 hrs postmortem at 2-4 oC. The transported sheep had significantly (P<0.05 higher cortisol adrenaline, nor-adrenaline, and dopamine levels than the non-transported group. Muscles from electrically-stimulated carcasses had significantly (P<0.05 lower pH values, longer sarcomere length, lower shear force value, higher expressed juice, myofibrillar fragmentation index and L* values than those from non-stimulated ones. Transportation significantly influenced meat quality characteristics of the Longissimus dorsi muscle. Muscle ultimate pH and shear force values were significantly higher, while CIE L*, a*, b*, expressed juice and cooking loss were lower in transported than non-transported sheep. This study indicated that pre-slaughter transportation at high ambient temperatures can cause noticeable changes in muscle physiology in sheep. Nevertheless, meat quality of transported

  11. Optimal Coordinated Management of a Plug-In Electric Vehicle Charging Station under a Flexible Penalty Contract for Voltage Security

    Directory of Open Access Journals (Sweden)

    Jip Kim

    2016-07-01

    Full Text Available The increasing penetration of plug-in electric vehicles (PEVs may cause a low-voltage problem in the distribution network. In particular, the introduction of charging stations where multiple PEVs are simultaneously charged at the same bus can aggravate the low-voltage problem. Unlike a distribution network operator (DNO who has the overall responsibility for stable and reliable network operation, a charging station operator (CSO may schedule PEV charging without consideration for the resulting severe voltage drop. Therefore, there is a need for the DNO to impose a coordination measure to induce the CSO to adjust its charging schedule to help mitigate the voltage problem. Although the current time-of-use (TOU tariff is an indirect coordination measure that can motivate the CSO to shift its charging demand to off-peak time by imposing a high rate at the peak time, it is limited by its rigidity in that the network voltage condition cannot be flexibly reflected in the tariff. Therefore, a flexible penalty contract (FPC for voltage security to be used as a direct coordination measure is proposed. In addition, the optimal coordinated management is formulated. Using the Pacific Gas and Electric Company (PG&E 69-bus test distribution network, the effectiveness of the coordination was verified by comparison with the current TOU tariff.

  12. Electrical Power Supply to Offshore Oil Installations by High Voltage Direct Current Transmission

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, Joergen Chr.

    2001-07-01

    This study was initiated to investigate if it could be feasible to supply offshore oil installations in the North Sea with electrical power from land. A prestudy of alternative converter topologies indicated that the most promising solution would be to investigate a conventional system with reduced synchronous compensator rating. The study starts with a summary of the state of power supply to offshore installations today, and a short review of classical HVDC transmission. It goes on to analyse how a passive network without sources influences the inverter. The transmission, with its current controlled rectifier and large inductance, is simulated as a current source. Under these circumstances the analysis shows that the network frequency has to adapt in order to keep the active and reactive power balance until the controllers are able to react. The concept of firing angle for a thyristor is limited in a system with variable frequency, the actual control parameter is the firing delay time. Sensitivity analysis showed some astonishing consequences. The frequency rises both by an increase in the active and in the reactive load. The voltage falls by an increase in the active load, but rises by an increase in the inductive load. Two different control principles for the system of inverter, synchronous compensator and load are defined. The first takes the reference for the firing delay time from the fundamental voltage at the point of common coupling. The second takes the reference for the firing delay time from the simulated EMF of the synchronous compensator. Of these, the second is the more stable and should be chosen as the basis for a possible control system. Two simulation tools are applied. The first is a quasi-phasor model running on Matlab with Simulink. The other is a time domain model in KREAN. The time domain model is primarily used for the verification of the quasi-phasor model, and shows that quasi-phasors is still a valuable tool for making a quick analysis

  13. Space Charge Modulated Electrical Breakdown of Oil Impregnated Paper Insulation Subjected to AC-DC Combined Voltages

    Directory of Open Access Journals (Sweden)

    Yuanwei Zhu

    2018-06-01

    Full Text Available Based on the existing acknowledgment that space charge modulates AC and DC breakdown of insulating materials, this investigation promotes the related investigation into the situations of more complex electrical stress, i.e., AC-DC combined voltages. Experimentally, the AC-DC breakdown characteristics of oil impregnated paper insulation were systematically investigated. The effects of pre-applied voltage waveform, AC component ratio, and sample thickness on AC-DC breakdown characteristics were analyzed. After that, based on an improved bipolar charge transport model, the space charge profiles and the space charge induced electric field distortion during AC-DC breakdown were numerically simulated to explain the differences in breakdown characteristics between the pre-applied AC and pre-applied DC methods under AC-DC combined voltages. It is concluded that large amounts of homo-charges are accumulated during AC-DC breakdown, which results in significantly distorted inner electric field, leading to variations of breakdown characteristics of oil impregnated paper insulation. Therefore, space charges under AC-DC combined voltages must be considered in the design of converter transformers. In addition, this investigation could provide supporting breakdown data for insulation design of converter transformers and could promote better understanding on the breakdown mechanism of insulating materials subjected to AC-DC combined voltages.

  14. The impacts of voltage sags in industrial electric systems; Os impactos dos afundamentos de tensao em sistemas eletricos industriais

    Energy Technology Data Exchange (ETDEWEB)

    Maia, Reinaldo Moreira [Moinhos Vera Cruz, Santa Luzia, MG (Brazil); Silva, Selenio Rocha [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2010-10-15

    The sensitiveness increasing of industrial equipment related to the perturbation of electric grid, resulting in losses to the productive chain, turns the energy quality in the subject more discussed by the electrical community. In this study case on the problems caused by voltage sags to equipment of an industrial plant from the food sector, it is presented the identification process and the adopted solutions. (author)

  15. Effect of different gas stunning methods on Manchega suckling lamb meat packed under different modified atmospheres.

    Science.gov (United States)

    Bórnez, R; Linares, M B; Vergara, H

    2010-04-01

    Forty-nine Manchega breed male suckling lambs were used in this experiment. The effect of CO(2) concentration and exposure time at stunning [80% CO(2) for 90 s (G1); 90% CO(2) for 90 s (G2); 90% CO(2) for 60 s (G3); 80% CO(2) for 60 s (G4)] plus an electrically stunned control group (G5) was assessed for pH, colour (L(*), a(*), b(*), C(*) and h(*)), water holding capacity (WHC), drip loss (DL), cooking loss (CL) and shear force (SF) in samples packed under two different types of modified atmospheres (MA: MA A: 70%O(2)+30%CO(2); MA B: 69.3%N(2)+30%CO(2)+0.7%CO) at 7, 14 and 21 d post-packaging. The lowest pH was found in G4 and in G5. The highest WHC and the lowest CL were found in G2 and G3 groups (P<0.05). Modified atmospheres did not affect on pH, WHC, CL and DL, although a significant effect (P<0.001) on colour was found at all the analysis times. Both the type of stunning and the modified atmosphere affected SF values. 2009 Elsevier Ltd. All rights reserved.

  16. Effect of different stunning systems on meat quality of light lamb.

    Science.gov (United States)

    Linares, M B; Bórnez, R; Vergara, H

    2007-08-01

    The present study was proposed to compare the effect that different types of stunning (TS) had on the quality of refrigerated meat from light lambs of the Spanish Manchega breed at 24h and 7 days post-mortem. Lambs were electrically stunned (ESL; n=10), using CO(2) (GSL; n=10) or slaughtered without previous stunning (USL; n=10). Measurements on meat quality were carried out by evaluating pH, colour coordinates (L(∗), a(∗), b(∗)), water holding capacity (WHC), cooking loss (CL), shear force (SF) and drip loss (DL). At 24h post-mortem, no significant differences were found in any of the variables studied. However, at 7 days post-mortem, meat quality was affected by the different TS: pH, CL and DL were lower (P<0.001) in the USL group and GSL obtained the lowest a(∗) (redness) and b(∗) (yellowness) values (P<0.01) than in the other groups. Ageing of meat affected SF in the ESL group (P<0.01), although there were no significant differences due to treatments at any of the ageing times.

  17. Integration of 100% heat pumps and electric vehicles in the low voltage distribution network: A Danish case story

    DEFF Research Database (Denmark)

    Shao, Nan; You, Shi; Segerberg, Helena

    2013-01-01

    The existing electricity infrastructure may to a great extent limit a high penetration of micro-sized Distributed Energy Rescores (DERs), due to physical bottlenecks, e.g. load capacities of cables and transformers and voltage limitations. In this study, integration impacts of heat pumps (HPs) an...

  18. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wafa Tourab

    2016-06-01

    Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  19. Module Seven: Combination Circuits and Voltage Dividers; Basic Electricity and Electronics Individualized Learning System.

    Science.gov (United States)

    Bureau of Naval Personnel, Washington, DC.

    In this module the student will learn to apply the rules previously learned for series and parallel circuits to more complex circuits called series-parallel circuits, discover the utility of a common reference when making reference to voltage values, and learn how to obtain a required voltage from a voltage divider network. The module is divided…

  20. Impact of pulsed-electric field and high-voltage electrical discharges on red wine microbial stabilization and quality characteristics.

    Science.gov (United States)

    Delsart, C; Grimi, N; Boussetta, N; Miot Sertier, C; Ghidossi, R; Vorobiev, E; Mietton Peuchot, M

    2016-01-01

    In this study, pulsed-electric fields (PEF) and high-voltage electrical discharges (HVED) are proposed as new techniques for the microbial stabilization of red wines before bottling. The efficiency of the treatment was then evaluated. PEF and HVED-treatments have been applied to wine for the inactivation of Oenococcus oeni CRBO 9304, O. oeni CRBO 0608, Pediococcus parvulus CRBO 2.6 and Brettanomyces bruxellensis CB28. Different treatment times (1, 2, 4, 6, 8 and 10 ms) were used at 20 kV cm(-1) for the PEF treatments and at 40 kV for the HVED treatments, which correspond to applied energies from 80 to 800 kJ l(-1) . The effects of the treatments on the microbial inactivation rate and on various characteristics of red wines (phenolic composition, chromatic characteristics and physico-chemical parameters) were measured. The application of PEF or HVED treatments on red wine allowed the inactivation of alteration yeasts (B. bruxellensis CB28) and bacteria (O. oeni CRBO 9304, O. oeni CRBO 0608 and P. parvulus CRBO 2.6). The electric discharges at 40 kV were less effective than the PEF even after 10 ms of treatments. Indeed, 4 ms of PEF treatment at 20 kV cm(-1) were sufficient to inactivate all micro-organisms present in the wines. Also, the use of PEF had no negative impact on the composition of wines compared to the HVED treatments. Contrary to PEF, the phenolics compounds were degraded after the HVED treatment and the physico-chemical composition of wine were modified with HVED. PEF technology seems to be an interesting alternative to stabilize microbiologically wines before bottling and without modifying their composition. This process offers many advantages for winemakers: no chemical inputs, low energy consumption (320 kJ l(-1) ), fast (treatment time of 4 ms) and athermal (ΔT ≈ 10°C). © 2015 The Society for Applied Microbiology.

  1. A methodological reappraisal of non invasive high voltage electrical stimulation of lumbosacral nerve roots.

    Science.gov (United States)

    Troni, Walter; Di Sapio, Alessia; Berra, Eliana; Duca, Sergio; Merola, Aristide; Sperli, Francesca; Bertolotto, Antonio

    2011-10-01

    To describe a neurophysiological method to locate the optimal stimulation site (OSS) over the vertebral column, customized to the individual subject, to achieve maximal activation of lumbosacral roots by means of non-invasive high voltage electrical stimulation (HVES). OSS was located in 30 volunteers by testing different stimulation points of a surface multi-electrode array placed over the dorso-lumbar junction of the vertebral column. The dorso-ventral stimulating montage was used (Troni et al., 1996). Motor responses to root stimulation (rCMAPs) were bilaterally recorded from Vastus Medialis (VM), Tibialis Anterior (TA), Soleus (SL) and Flexor Hallucis Brevis (FHB) muscles. The direct nature of rCMAPs was tested by delivering two maximal stimuli 50 ms apart. Except for a few subjects with large girth, maximal rCMAPs could be obtained from all muscles with a stimulating current intensity up to 550 V (1050 mA). Maximal double HVES excluded any reflex component in the recorded rCMAPs. The procedure was well tolerated and no side effects were observed. A single maximal electric shock delivered at the proper vertebral level by means of the dorso-ventral montage is able to safely achieve synchronous, bilateral maximal activation of several roots, from L3 to S1. Maximal activation of lumbosacral roots at their origin, unattainable with magnetic stimulation, is the essential requirement for direct detection of proximal nerve conduction slowing and block in lower limbs. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  2. Electric organ discharge diversification in mormyrid weakly electric fish is associated with differential expression of voltage-gated ion channel genes.

    Science.gov (United States)

    Nagel, Rebecca; Kirschbaum, Frank; Tiedemann, Ralph

    2017-03-01

    In mormyrid weakly electric fish, the electric organ discharge (EOD) is used for species recognition, orientation and prey localization. Produced in the muscle-derived adult electric organ, the EOD exhibits a wide diversity across species in both waveform and duration. While certain defining EOD characteristics can be linked to anatomical features of the electric organ, many factors underlying EOD differentiation are yet unknown. Here, we report the differential expression of 13 Kv1 voltage-gated potassium channel genes, two inwardly rectifying potassium channel genes, two previously studied sodium channel genes and an ATPase pump in two sympatric species of the genus Campylomormyrus in both the adult electric organ and skeletal muscle. Campylomormyrus compressirostris displays a basal EOD, largely unchanged during development, while C. tshokwe has an elongated, putatively derived discharge. We report an upregulation in all Kv1 genes in the electric organ of Campylomormyrus tshokwe when compared to both skeletal muscle and C. compressirostris electric organ. This pattern of upregulation in a species with a derived EOD form suggests that voltage-gated potassium channels are potentially involved in the diversification of the EOD signal among mormyrid weakly electric fish.

  3. The principles of high voltage electric field and its application in food processing: A review.

    Science.gov (United States)

    Dalvi-Isfahan, Mohsen; Hamdami, Nasser; Le-Bail, Alain; Xanthakis, Epameinondas

    2016-11-01

    Food processing is a major part of the modern global industry and it will certainly be an important sector of the industry in the future. Several processes for different purposes are involved in food processing aiming at the development of new products by combining and/or transforming raw materials, to the extension of food shelf-life, recovery, exploitation and further use of valuable compounds and many others. During the last century several new food processes have arisen and most of the traditional ones have evolved. The future food factory will require innovative approaches food processing which can combine increased sustainability, efficiency and quality. Herein, the objective of this review is to explore the multiple applications of high voltage electric field (HVEF) and its potentials within the food industry. These applications include processes such as drying, refrigeration, freezing, thawing, extending food shelf- life, and extraction of biocompounds. In addition, the principles, mechanism of action and influence of specific parameters have been discussed comprehensively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Design of High Voltage Electrical Breakdown Strength measuring system at 1.8K with a G-M cryocooler

    Science.gov (United States)

    Li, Jian; Huang, Rongjin; Li, Xu; Xu, Dong; Liu, Huiming; Li, Laifeng

    2017-09-01

    Impregnating resins as electrical insulation materials for use in ITER magnets and feeder system are required to be radiation stable, good mechanical performance and high voltage electrical breakdown strength. In present ITER project, the breakdown strength need over 30 kV/mm, for future DEMO reactor, it will be greater than this value. In order to develop good property insulation materials to satisfy the requirements of future fusion reactor, high voltage breakdown strength measurement system at low temperature is necessary. In this paper, we will introduce our work on the design of this system. This measuring system has two parts: one is an electrical supply system which provides the high voltage from a high voltage power between two electrodes; the other is a cooling system which consists of a G-M cryocooler, a superfluid chamber and a heat switch. The two stage G-M cryocooler pre-cool down the system to 4K, the superfluid helium pot is used for a container to depress the helium to superfluid helium which cool down the sample to 1.8K and a mechanical heat switch connect or disconnect the cryocooler and the pot. In order to provide the sufficient time for the test, the cooling system is designed to keep the sample at 1.8K for 300 seconds.

  5. Frequency and voltage dependent profile of dielectric properties, electric modulus and ac electrical conductivity in the PrBaCoO nanofiber capacitors

    Directory of Open Access Journals (Sweden)

    S. Demirezen

    Full Text Available In this study, praseodymium barium cobalt oxide nanofiber interfacial layer was sandwiched between Au and n-Si. Frequency and voltage dependence of ε′, ε′, tanδ, electric modulus (M′ and M″ and σac of PrBaCoO nanofiber capacitor have been investigated by using impedance spectroscopy method. The obtained experimental results show that the values of ε′, ε′, tanδ, M′, M″ and σac of the PrBaCoO nanofiber capacitor are strongly dependent on frequency of applied bias voltage. The values of ε′, ε″ and tanδ show a steep decrease with increasing frequency for each forward bias voltage, whereas the values of σac and the electric modulus increase with increasing frequency. The high dispersion in ε′ and ε″ values at low frequencies may be attributed to the Maxwell–Wagner and space charge polarization. The high values of ε′ may be due to the interfacial effects within the material, PrBaCoO nanofibers interfacial layer and electron effect. The values of M′ and M″ reach a maximum constant value corresponding to M∞ ≈ 1/ε∞ due to the relaxation process at high frequencies, but both the values of M′ and M″ approach almost to zero at low frequencies. The changes in the dielectric and electrical properties with frequency can be also attributed to the existence of Nss and Rs of the capacitors. As a result, the change in the ε′, ε″, tanδ, M′, M″ and ac electric conductivity (σac is a result of restructuring and reordering of charges at the PrBaCoO/n-Si interface under an external electric field or voltage and interface polarization. Keywords: Thin films, Electrical properties, Interface/interphase

  6. Improvement of Voltage Stability in Electrical Network by Using a STATCOM

    Directory of Open Access Journals (Sweden)

    Kamel MERINI

    2014-02-01

    Full Text Available This paper aims to clarify power flow without and with static synchronous compensator (STATCOM and searching the best location of STATCOM to improve voltage in the Algerian network. In daily operation where there are all kinds of disturbances such as voltage fluctuations, voltage sags, swells, voltage unbalances and harmonics. STATCOM is modeled as a controllable voltage source. To validate the effectiveness of the Newton-Raphson method algorithm was implemented to solve power flow equations in presence of STATCOM. Case studies are carried out on 59-bus Algerian network test to demonstrate the performance of proposed models. Simulation results show the effectiveness and capability of STATCOM in improving voltage regulation in transmission systems; moreover the power solution using the Newton-Raphson algorithm developed. The STATCOM and the detailed simulation are performed using Matlab program.

  7. Decomposition of Composite Electric Field in a Three-Phase D-Dot Voltage Transducer Measuring System

    Directory of Open Access Journals (Sweden)

    Xueqi Hu

    2016-10-01

    Full Text Available In line with the wider application of non-contact voltage transducers in the engineering field, transducers are required to have better performance for different measuring environments. In the present study, the D-dot voltage transducer is further improved based on previous research in order to meet the requirements for long-distance measurement of electric transmission lines. When measuring three-phase electric transmission lines, problems such as synchronous data collection and composite electric field need to be resolved. A decomposition method is proposed with respect to the superimposed electric field generated between neighboring phases. The charge simulation method is utilized to deduce the decomposition equation of the composite electric field and the validity of the proposed method is verified by simulation calculation software. With the deduced equation as the algorithm foundation, this paper improves hardware circuits, establishes a measuring system and constructs an experimental platform for examination. Under experimental conditions, a 10 kV electric transmission line was tested for steady-state errors, and the measuring results of the transducer and the high-voltage detection head were compared. Ansoft Maxwell Stimulation Software was adopted to obtain the electric field intensity in different positions under transmission lines; its values and the measuring values of the transducer were also compared. Experimental results show that the three-phase transducer is characterized by a relatively good synchronization for data measurement, measuring results with high precision, and an error ratio within a prescribed limit. Therefore, the proposed three-phase transducer can be broadly applied and popularized in the engineering field.

  8. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  9. Results of a literature review on the environmental qualification of low-voltage electric cables

    International Nuclear Information System (INIS)

    Lofaro, R.; Lee, B.; Villaran, M.; Gleason, J.; Aggarwal, S.

    1995-01-01

    In the design of nuclear power plants in the US, safety-related electric equipment must be qualified to provide reasonable assurance it can withstand the effects of a design basis event (DBE) and still be able to perform its prescribed safety function, even if the accident were to occur at the end of its service life. The requirement for environmental qualification (EQ) originates from the General Design Criteria in the Code of Federal Regulations, Title 10, Part 50 (10 CFR 50). The acceptable method of performing the qualification of this equipment has evolved over the years, starting with the NRC Division of Operating Reactors (DOR) Guidelines, which were issued in Bulletin 79--01B, and NUREG-0588 requirements and ending with the current EQ Rule, 10 CFR 50.49. While the EQ methods described in these documents have the same overall objective, there are some notable differences for which a clear technical basis has not been established. One difference is the preaging requirement for equipment prior to LOCA testing. In addition, specific issues related to current EQ practices have been raised by the US NRC which need to be addressed. These issues, which are discussed in detail later in this paper, are related to the sources of conservatism and uncertainty in IEEE Standard 323--1974, which is the qualification standard currently endorsed by the NRC. To address these issues, the NRC Office of Nuclear Reactor Regulation (NRR) implemented a Task Action Plan (TAP), and the Office of Nuclear Reactor Research (RES) initiated a complementary research program. The current focus of this program is on the qualification of low-voltage instrumentation and control cables. These cables were selected since they are not typically replaced on a routine basis, and their degradation could impact plant safety

  10. The effect of high voltage, high frequency pulsed electric field on slain ovine cortical bone.

    Science.gov (United States)

    Asgarifar, Hajarossadat; Oloyede, Adekunle; Zare, Firuz

    2014-04-01

    High power, high frequency pulsed electric fields known as pulsed power (PP) has been applied recently in biology and medicine. However, little attention has been paid to investigate the application of pulse power in musculoskeletal system and its possible effect on functional behavior and biomechanical properties of bone tissue. This paper presents the first research investigating whether or not PP can be applied safely on bone tissue as a stimuli and what will be the possible effect of these signals on the characteristics of cortical bone by comparing the mechanical properties of this type of bone pre and post expose to PP and in comparison with the control samples. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses (up to 500 V and 10 kHz). The functional behavior of bone in response to pulse power excitation was elucidated by applying compressive loading until failure. The stiffness, failure stress (strength) and the total fracture energy (bone toughness) were determined as a measure of the main bone characteristics. Furthermore, an ultrasonic technique was applied to determine and comprise bone elasticity before and after pulse power stimulation. The elastic property of cortical bone samples appeared to remain unchanged following exposure to pulse power excitation for all three orthogonal directions obtained from ultrasonic technique and similarly from the compression test. Nevertheless, the compressive strength and toughness of bone samples were increased when they were exposed to 66 h of high power pulsed electromagnetic field compared to the control samples. As the toughness and the strength of the cortical bone tissue are directly associated with the quality and integrity of the collagen matrix whereas its stiffness is primarily related to bone mineral content these overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network

  11. Frequency and voltage dependent electrical responses of poly(triarylamine thin film-based organic Schottky diode

    Directory of Open Access Journals (Sweden)

    Mohamad Khairul Anuar

    2017-01-01

    Full Text Available A metal-organic-metal (MOM type Schottky diode based on poly (triarylamine (PTAA thin films has been fabricated by using the spin coating method. Investigation of the frequency dependent conductance-voltage (G-V-f and capacitance-voltage (C-V-f characteristics of the ITO/PTAA/Al MOM type diode were carried out in the frequency range from 12 Hz to 100 kHz using an LCR meter at room temperature. The frequency and bias voltage dependent electrical response were determined by admittance-based measured method in terms of an equivalent circuit model of the parallel combination of resistance and capacitance (RC circuit. Investigation revealed that the conductance is frequency and a bias voltage dependent in which conductance continuous increase as the increasing frequency, respectively. Meanwhile, the capacitance is dependent on frequency up to a certain value of frequency (100 Hz but decreases at high frequency (1 – 10 kHz. The interface state density in the Schottky diode was determined from G-V and C-V characteristics. The interface state density has values almost constant of 2.8 x 1012 eV−1cm−2 with slightly decrease by increasing frequencies. Consequently, both series resistance and interface trap density were found to decrease with increasing frequency. The frequency dependence of the electrical responses is attributed the distribution density of interface states that could follow the alternating current (AC signal.

  12. Frequency and voltage dependent electrical responses of poly(triarylamine) thin film-based organic Schottky diode

    Science.gov (United States)

    Anuar Mohamad, Khairul; Tak Hoh, Hang; Alias, Afishah; Ghosh, Bablu Kumar; Fukuda, Hisashi

    2017-11-01

    A metal-organic-metal (MOM) type Schottky diode based on poly (triarylamine) (PTAA) thin films has been fabricated by using the spin coating method. Investigation of the frequency dependent conductance-voltage (G-V-f) and capacitance-voltage (C-V-f) characteristics of the ITO/PTAA/Al MOM type diode were carried out in the frequency range from 12 Hz to 100 kHz using an LCR meter at room temperature. The frequency and bias voltage dependent electrical response were determined by admittance-based measured method in terms of an equivalent circuit model of the parallel combination of resistance and capacitance (RC circuit). Investigation revealed that the conductance is frequency and a bias voltage dependent in which conductance continuous increase as the increasing frequency, respectively. Meanwhile, the capacitance is dependent on frequency up to a certain value of frequency (100 Hz) but decreases at high frequency (1 - 10 kHz). The interface state density in the Schottky diode was determined from G-V and C-V characteristics. The interface state density has values almost constant of 2.8 x 1012 eV-1cm-2 with slightly decrease by increasing frequencies. Consequently, both series resistance and interface trap density were found to decrease with increasing frequency. The frequency dependence of the electrical responses is attributed the distribution density of interface states that could follow the alternating current (AC) signal.

  13. The effect of gate voltage on the electrical transport properties in the contacts of C60 to carbon nanotube leads

    Directory of Open Access Journals (Sweden)

    AA Shokri

    2012-06-01

    Full Text Available  In this paper, we examined the effect of gate voltage, bias voltage, contact geometries and the different bond lengths on the electrical transport properties in a nanostructure consisting of C60 molecule attached to two semi-infinite leads made of single wall carbon nanotubes in the coherent regime. Our calculation was based on the Green’s function method within nearest-neighbour tight-binding approximation. After the calculation was of transmission, the electrical current was obtained by the Landauer-Buttiker formula. Next, the effect of the mentioned factors was investigated in the nanostructure. The application of the present results may be useful in designing devices based on molecular electronics in nanoscale.

  14. Detecting electroporation by assessing the time constants in the exponential response of human skin to voltage controlled impulse electrical stimulation.

    Science.gov (United States)

    Bîrlea, Sinziana I; Corley, Gavin J; Bîrlea, Nicolae M; Breen, Paul P; Quondamatteo, Fabio; OLaighin, Gearóid

    2009-01-01

    We propose a new method for extracting the electrical properties of human skin based on the time constant analysis of its exponential response to impulse stimulation. As a result of this analysis an adjacent finding has arisen. We have found that stratum corneum electroporation can be detected using this analysis method. We have observed that a one time-constant model is appropriate for describing the electrical properties of human skin at low amplitude applied voltages (30V). Higher voltage amplitudes (>30V) have been proven to create pores in the skin's stratum corneum which offer a new, lower resistance, pathway for the passage of current through the skin. Our data shows that when pores are formed in the stratum corneum they can be detected, in-vivo, due to the fact that a second time constant describes current flow through them.

  15. Management of Power Quality Issues in Low Voltage Networks using Electric Vehicles: Experimental Validation

    DEFF Research Database (Denmark)

    Martinenas, Sergejus; Knezovic, Katarina; Marinelli, Mattia

    2017-01-01

    the existing and future power quality problems. One of the main aspects of the power quality relates to voltage quality. The aim of this work is to experimentally analyse whether series-produced EVs, adhering to contemporary standard and without relying on any V2G capability, can mitigate line voltage drops...... in improving the power quality of a highly unbalanced grid...

  16. Module Five: Relationships of Current, Voltage, and Resistance; Basic Electricity and Electronics Individualized Learning System.

    Science.gov (United States)

    Bureau of Naval Personnel, Washington, DC.

    This module covers the relationships between current and voltage; resistance in a series circuit; how to determine the values of current, voltage, resistance, and power in resistive series circuits; the effects of source internal resistance; and an introduction to the troubleshooting of series circuits. This module is divided into five lessons:…

  17. Calculation of Voltages in Electric Power Transmission Lines During Historic Geomagnetic Storms: An Investigation Using Realistic Earth Impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-02-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  18. Calculation of voltages in electric power transmission lines during historic geomagnetic storms: An investigation using realistic earth impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-01-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  19. Urban exposure to ELF magnetic field due to high-, medium- and low-voltage electricity supply networks

    International Nuclear Information System (INIS)

    Bottura, V.; Cappio Borlino, M.; Carta, N.; Cerise, L.; Imperial, E.

    2009-01-01

    The regional environment protection agency (ARPA) of the Aosta Valley region in north Italy performed a survey of magnetic field triggered by the power supply network in high, medium and low voltages on the entire area of Aosta town. The electrical distribution system for houses was not however taken into account. The aim of the survey was to evaluate the global population exposure and not simply the assessment of the legal exposure limit compliance. (authors)

  20. Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system

    Directory of Open Access Journals (Sweden)

    Vrcelj Nada

    2013-01-01

    Full Text Available The method is based on data obtained from the so-called. hand-held measuring current at 10 kV voltage level and from reports of outages at reclosers that are installed in a part of network that is observed. At first, is calculates the electrical load of the main distribution power lines, and then simulates the corresponding power flow and calculates the undelivered electricity. The method was applied to parts of the network PD ED Belgrade that are not in the remote control system and is developed for the purpose of considering the effects of automation in the 10 kV PD ED Belgrade.

  1. High voltage-derived enhancement of electric conduction in nanogap devices for detection of prostate-specific antigen

    Science.gov (United States)

    Park, Hyung Ju; Chi, Young Shik; Choi, Insung S.; Yun, Wan Soo

    2010-07-01

    We report a simple method of enhancing electric conductance in nanogap devices without any additional treatments, such as silver-enhancing process. The low electric conductance after selective immobilization of biofunctionalized gold nanoparticles in the gap region was greatly enhanced by repeated I-V scans at relatively high voltage ranges of -5 to 5 V, which was attributed to the formation of a new conduction pathway across the gap. The higher conduction state of the nanogap device showed a very stable I-V curve, which was used as an excellent measure of the existence of prostate-specific antigen.

  2. Transmission congestion and voltage profile management coordination in competitive electricity markets

    International Nuclear Information System (INIS)

    Yamin, H.Y.; Shahidehpour, S.M.

    2003-01-01

    This paper describes a generalized active/reactive iterative coordination process between GENCOs and the Independent System Operator (ISO) for active (transmission congestion) and reactive (voltage profile) management in the day-ahead market. GENCOs apply priced-based unit commitment without transmission and voltage security constraints, schedule their units and submit their initial bids to the ISO. The ISO executes congestion and voltage profile management for eliminating transmission and voltage profile violations. If violations are not eliminated, the ISO minimizes the transmission and voltage profile violations and sends a signal via the Internet to GENCOs. GENCOs reschedule their units taking into account the ISO signals and submit modified bids to the ISO. The voltage problem is addressed and a linear model is formulated and used in the proposed method. The voltage problem is formulated as a linear programming with a block-angular structure and Dantzig-Wolfe decomposition is applied to generate several smaller problems for a faster and easier solution of large-scale power systems. Two 36 unit GENCOs are used to demonstrate the performance of the proposed generalized active/reactive coordination algorithm. (author)

  3. Voltage profile program for the Kennedy Space Center electric power distribution system

    Science.gov (United States)

    1976-01-01

    The Kennedy Space Center voltage profile program computes voltages at all busses greater than 1 Kv in the network under various conditions of load. The computation is based upon power flow principles and utilizes a Newton-Raphson iterative load flow algorithm. Power flow conditions throughout the network are also provided. The computer program is designed for both steady state and transient operation. In the steady state mode, automatic tap changing of primary distribution transformers is incorporated. Under transient conditions, such as motor starts etc., it is assumed that tap changing is not accomplished so that transformer secondary voltage is allowed to sag.

  4. Low Voltage Electrolytic Capacitor Pulse Forming Inductive Network for Electric Weapons

    National Research Council Canada - National Science Library

    Mays, Thomas A

    2006-01-01

    .... Pulsed alternators potentially have the same maintenance issues as other motor-generator sets, so a solid-state system would be desirable, but high voltage capacitor systems are not robust enough for the field...

  5. Voltage control and protection in electrical power systems from system components to wide-area control

    CERN Document Server

    Corsi, Sandro

    2015-01-01

    Based on the author’s twenty years of experience, this book shows the practicality of modern, conceptually new, wide area voltage control in transmission and distribution smart grids, in detail. Evidence is given of the great advantages of this approach, as well as what can be gained by new control functionalities which modern technologies now available can provide. The distinction between solutions of wide area voltage regulation (V-WAR) and wide area voltage protection (V-WAP) are presented, demonstrating the proper synergy between them when they operate on the same power system as well as the simplicity and effectiveness of the protection solution in this case. The author provides an overview and detailed descriptions of voltage controls, distinguishing between generalities of underdeveloped, on-field operating applications and modern and available automatic control solutions, which are as yet not sufficiently known or perceived for what they are: practical, high-performance and reliable solutions. At th...

  6. Project resumes: biological effects from electric fields associated with high-voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

  7. Impact of low atmosphere pressure stunning of broilers on breast skin Salmonella and Campylobacter post-defeathering and breast fillet meat quality

    Science.gov (United States)

    Low atmosphere pressure stun (LAPS) is a method of controlled atmosphere poultry slaughter that utilizes a decrease of atmospheric pressure (0.2 ATM) to induce unconsciousness and death. Following feed withdrawal periods of 4, 6, 8, or 10 hours, broilers were slaughtered using LAPS or electrical stu...

  8. Voltage- and current-activated metal–insulator transition in VO2-based electrical switches: a lifetime operation analysis

    Directory of Open Access Journals (Sweden)

    Aurelian Crunteanu, Julien Givernaud, Jonathan Leroy, David Mardivirin, Corinne Champeaux, Jean-Christophe Orlianges, Alain Catherinot and Pierre Blondy

    2010-01-01

    Full Text Available Vanadium dioxide is an intensively studied material that undergoes a temperature-induced metal–insulator phase transition accompanied by a large change in electrical resistivity. Electrical switches based on this material show promising properties in terms of speed and broadband operation. The exploration of the failure behavior and reliability of such devices is very important in view of their integration in practical electronic circuits. We performed systematic lifetime investigations of two-terminal switches based on the electrical activation of the metal–insulator transition in VO2 thin films. The devices were integrated in coplanar microwave waveguides (CPWs in series configuration. We detected the evolution of a 10 GHz microwave signal transmitted through the CPW, modulated by the activation of the VO2 switches in both voltage- and current-controlled modes. We demonstrated enhanced lifetime operation of current-controlled VO2-based switching (more than 260 million cycles without failure compared with the voltage-activated mode (breakdown at around 16 million activation cycles. The evolution of the electrical self-oscillations of a VO2-based switch induced in the current-operated mode is a subtle indicator of the material properties modification and can be used to monitor its behavior under various external stresses in sensor applications.

  9. Current, voltage and temperature distribution modeling of light-emitting diodes based on electrical and thermal circuit analysis

    International Nuclear Information System (INIS)

    Yun, J; Shim, J-I; Shin, D-S

    2013-01-01

    We demonstrate a modeling method based on the three-dimensional electrical and thermal circuit analysis to extract current, voltage and temperature distributions of light-emitting diodes (LEDs). In our model, the electrical circuit analysis is performed first to extract the current and voltage distributions in the LED. Utilizing the result obtained from the electrical circuit analysis as distributed heat sources, the thermal circuit is set up by using the duality between Fourier's law and Ohm's law. From the analysis of the thermal circuit, the temperature distribution at each epitaxial film is successfully obtained. Comparisons of experimental and simulation results are made by employing an InGaN/GaN multiple-quantum-well blue LED. Validity of the electrical circuit analysis is confirmed by comparing the light distribution at the surface. Since the temperature distribution at each epitaxial film cannot be obtained experimentally, the apparent temperature distribution is compared at the surface of the LED chip. Also, experimentally obtained average junction temperature is compared with the value calculated from the modeling, yielding a very good agreement. The analysis method based on the circuit modeling has an advantage of taking distributed heat sources as inputs, which is essential for high-power devices with significant self-heating. (paper)

  10. Microstructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique

    Directory of Open Access Journals (Sweden)

    Igor Bogachev

    2015-11-01

    Full Text Available Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10–15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. The choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

  11. Microstructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique.

    Science.gov (United States)

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; Chernov, Ivan; Staltsov, Maxim; Khasanov, Oleg; Olevsky, Eugene

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10-15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. The choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

  12. Control and Protection in Low Voltage Grid with Large Scale Renewable Electricity Generation

    DEFF Research Database (Denmark)

    Mustafa, Ghullam

    of the inverter controllers must be developed to Voltage-Frequency (VF) mode; and the others in either PV or PQ modes. The operation of the MG with several PV inverters and single VF inverter is similar to the operation of MG with a synchronous machine as slack bus. The VF inverter establishes the voltage...... of renewable energy based DGs are reduced CO2 emission, reduced operational cost as almost no fuel is used for their operation and less transmission and distribution losses as these units are normally built near to the load centers. This has also resulted in some operational challenges due to the unpredictable...... nature of such power generation sources. Some of the operational challenges include voltage variations due to power fluctuations coming from the DG units. On the other hand, it has also opened up some opportunities. One of the opportunities is islanding operation of the distribution system with DG unit...

  13. Electric field-induced ferromagnetic resonance in a CoFeB/MgO magnetic tunnel junction under dc bias voltages

    Science.gov (United States)

    Kanai, Shun; Gajek, Martin; Worledge, D. C.; Matsukura, Fumihiro; Ohno, Hideo

    2014-12-01

    We measure homodyne-detected ferromagnetic resonance (FMR) induced by the electric-field effect in a CoFeB/MgO/CoFeB magnetic tunnel junction (MTJ) with perpendicular magnetic easy axis under dc bias voltages up to 0.1 V. From the bias dependence of the resonant frequency, we find that the first order perpendicular magnetic anisotropy is modulated by the applied electric field, whereas the second order component is virtually independent of the electric field. The lineshapes of the FMR spectra are bias dependent, which are explained by the combination of electric-field effect and reflection of the bias voltage from the MTJ.

  14. Construction and use of a zebrafish heart voltage and calcium optical mapping system, with integrated electrocardiogram and programmable electrical stimulation

    Science.gov (United States)

    Lin, Eric; Craig, Calvin; Lamothe, Marcel; Sarunic, Marinko V.; Beg, Mirza Faisal

    2015-01-01

    Zebrafish are increasingly being used as a model of vertebrate cardiology due to mammalian-like cardiac properties in many respects. The size and fecundity of zebrafish make them suitable for large-scale genetic and pharmacological screening. In larger mammalian hearts, optical mapping is often used to investigate the interplay between voltage and calcium dynamics and to investigate their respective roles in arrhythmogenesis. This report outlines the construction of an optical mapping system for use with zebrafish hearts, using the voltage-sensitive dye RH 237 and the calcium indicator dye Rhod-2 using two industrial-level CCD cameras. With the use of economical cameras and a common 532-nm diode laser for excitation, the rate dependence of voltage and calcium dynamics within the atrial and ventricular compartments can be simultaneously determined. At 140 beats/min, the atrial action potential duration was 36 ms and the transient duration was 53 ms. With the use of a programmable electrical stimulator, a shallow rate dependence of 3 and 4 ms per 100 beats/min was observed, respectively. In the ventricle the action potential duration was 109 ms and the transient duration was 124 ms, with a steeper rate dependence of 12 and 16 ms per 100 beats/min. Synchronous electrocardiograms and optical mapping recordings were recorded, in which the P-wave aligns with the atrial voltage peak and R-wave aligns with the ventricular peak. A simple optical pathway and imaging chamber are detailed along with schematics for the in-house construction of the electrocardiogram amplifier and electrical stimulator. Laboratory procedures necessary for zebrafish heart isolation, cannulation, and loading are also presented. PMID:25740339

  15. Effect of high-voltage pulsed electric field (HPEF pretreatment on biogas production rates of hybrid Pennisetum by anaerobic fermentation

    Directory of Open Access Journals (Sweden)

    Baijuan Wang

    2018-02-01

    Full Text Available In this paper, the raw materials of hybrid Pennisetum were pretreated in different conditions of high voltage pulsed electric field (HPEF to improve its material utilization ratios and biogas production rates of anaerobic fermentation. Then, anaerobic digestion experiments were conducted within 32 days at moderate temperature (35 °C with TS mass fraction (6%, inoculation rate (20% and initial pH (7.0. It is indicated that compared with the control group, 9 groups of hybrid Pennisetum pretreated by HPEF are obviously superior in gas production efficiency of anaerobic fermentation, and higher in cumulative gas production, peak daily gas production and maximum methane concentration; that the most remarkable stimulation occurs in the HPEF condition of 15 kV/120 Hz/60 min, in that situation, the cumulative gas production in the fermentation period of 32 days is up to 9587 mL, 26.95% higher than that of the control group, the peak daily gas production increases and the range of peak period extends. It is demonstrated that the optimal HPEF pretreatment time is 60 min and three HPEF parameters have a better effect on gas production in the order of voltage > time > frequency; and that the effect degree of treatment parameters on peak daily gas production is voltage, frequency and time in turn. It is concluded that HPEF can improve material utilization ratio and gas production rate of hybrid Pennisetum by anaerobic fermentation and shorten the gas production cycle. By virtue of this physical pretreatment method, the resource of Pennisetum is utilized sufficiently and the classes of energy plants are enlarged effectively. Keywords: Hybrid Pennisetum, Anaerobic fermentation, High voltage pulsed electric field (HPEF, Biogas, Material utilization ratio, Gas generation rate, Model, Stimulation

  16. Four-point probe measurements using current probes with voltage feedback to measure electric potentials

    Science.gov (United States)

    Lüpke, Felix; Cuma, David; Korte, Stefan; Cherepanov, Vasily; Voigtländer, Bert

    2018-02-01

    We present a four-point probe resistance measurement technique which uses four equivalent current measuring units, resulting in minimal hardware requirements and corresponding sources of noise. Local sample potentials are measured by a software feedback loop which adjusts the corresponding tip voltage such that no current flows to the sample. The resulting tip voltage is then equivalent to the sample potential at the tip position. We implement this measurement method into a multi-tip scanning tunneling microscope setup such that potentials can also be measured in tunneling contact, allowing in principle truly non-invasive four-probe measurements. The resulting measurement capabilities are demonstrated for \

  17. Controlled Operation of the Islanded Portion of the International Council on Large Electric Systems (CIGRE Low Voltage Distribution Network

    Directory of Open Access Journals (Sweden)

    Ghullam Mustafa Bhutto

    2017-07-01

    Full Text Available In islanding, a portion of the power network, comprised of the loads and distributed generation (DG units, is isolated from the rest of the power grid and forms a micro grid (MG. In this condition, it becomes essential for the islanded MG to operate in a stable and controlled manner by providing ancillary services. When the MG is cut off from the main grid, the islanding must be detected by the DG units. In this condition it is essential that one of the controllers should be switched to the voltage-frequency (VF control mode. In islanding, the network loses it slack reference and this reference is established by a VF controller. The voltage and the frequency of the islanded MG deviate when disconnected from the transmission grid and these deviations are caused by the load-generation imbalance. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes a control strategy which can compensate the voltage and the frequency deviations in the islanded portion of the International Council on Large Electric Systems (CIGRE low voltage distribution network by using advanced power electronics devices such as STATCOMs for Photovoltaic (PV Units and Battery Energy Storage Systems (BESS STATCOMs (for battery units. The selection of the VF controller for the most suitable DG unit of this test network is also presented in this paper, and the effectiveness of the controllers is verified by presenting simulation results using DIgSILENT (DIgSILENT GmbH, Gomaringen, Germany power factory software version 15.0.

  18. Frequency and voltage dependence dielectric properties, ac electrical conductivity and electric modulus profiles in Al/Co{sub 3}O{sub 4}-PVA/p-Si structures

    Energy Technology Data Exchange (ETDEWEB)

    Bilkan, Çiğdem, E-mail: cigdembilkan@gmail.com [Department of Physics, Faculty of Sciences, The University of Çankırı Karatekin, 18100 Çankırı (Turkey); Azizian-Kalandaragh, Yashar [Department of Physics, Faculty of Science, The University of Mohaghegh Ardabili, Ardabil (Iran, Islamic Republic of); Altındal, Şemsettin [Department of Physics, Faculty of Sciences, The University of Gazi, 06500 Ankara (Turkey); Shokrani-Havigh, Roya [Department of Physics, Faculty of Science, The University of Mohaghegh Ardabili, Ardabil (Iran, Islamic Republic of)

    2016-11-01

    In this research a simple microwave-assisted method have been used for preparation of cobalt oxide nanostructures. The as-prepared sample has been investigated by UV–vis spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM). On the other hand, frequency and voltage dependence of both the real and imaginary parts of dielectric constants (ε′, ε″) and electric modulus (M′ and M″), loss tangent (tanδ), and ac electrical conductivity (σ{sub ac}) values of Al/Co{sub 3}O{sub 4}-PVA/p-Si structures were obtained in the wide range of frequency and voltage using capacitance (C) and conductance (G/ω) data at room temperature. The values of ε′, ε″ and tanδ were found to decrease with increasing frequency almost for each applied bias voltage, but the changes in these parameters become more effective in the depletion region at low frequencies due to the charges at surface states and their relaxation time and polarization effect. While the value of σ is almost constant at low frequency, increases almost as exponentially at high frequency which are corresponding to σ{sub dc} and σ{sub ac}, respectively. The M′ and M″ have low values at low frequencies region and then an increase with frequency due to short-range mobility of charge carriers. While the value of M′ increase with increasing frequency, the value of M″ shows two peak and the peaks positions shifts to higher frequency with increasing applied voltage due to the decrease of the polarization and N{sub ss} effects with increasing frequency.

  19. Concurrent Provision of Frequency Regulation and Overvoltage Support by Electric Vehicles in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Andersen, Peter Bach

    2014-01-01

    Expected deployment of electric vehicles (EVs) introduces big technical challenges for power system operation, but also offers advantages provided that EVs are not considered merely as passive loads. With the development of Vehicle-to-Grid technology, EVs will be able to provide a number...... of ancillary services for grid support, e.g. implemented electronic equipment will allow them to exchange reactive power with the grid for voltage regulation while using active power for other services. This paper investigates the concurrent provision of local and system wide services from EVs in a real Danish...

  20. MR imaging findings of high-voltage electrical burns in the upper extremities: correlation with angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyung Kyu; Kang, Ik Won; Hwang, Dae Hyun; Min, Seon Jung; Han, You Mi (Dept. of Radiology, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of)); Suh, Kyung Jin (Dept. of Radiology, Dongguk Univ. College of Medicine, Gyeongju Hospital, Gyeongju (Korea, Republic of)), email: kyungjin.suh@gmail.com; Choi, Min Ho (Dept. of Internal Medicine, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of))

    2011-02-15

    Background: A high-voltage electrical burn is often associated with deep muscle injuries. Hidden, undetected deep muscle injuries have a tendency for progressive tissue necrosis, and this can lead to major amputations or sepsis. MRI has excellent soft tissue contrast and it may aid in differentiating the areas of viable deep muscle from the areas of non-viable deep muscle. Purpose: To describe the MR imaging findings of a high-voltage electrical burn in the upper extremity with emphasis on the usefulness of the gadolinium-enhanced MRI and to compare the MR imaging findings with angiography. Material and Methods: We retrospectively reviewed the imaging studies of six patients with high-voltage electrical burns who underwent both MRI and angiography at the burn center of our hospital from January 2005 to December 2009. The imaging features were evaluated for the involved locations, the MR signal intensity of the affected muscles, the MR enhancement pattern, the involved arteries and the angiographic findings (classified as normal, sluggish flow, stenosis or occlusion) of the angiography of the upper extremity. We assessed the relationship between the MR imaging findings and the angiographic findings. Results: The signal intensities of affected muscles were isointense or of slightly high signal intensity as compared with the adjacent unaffected skeletal muscle on the T1-weighted MR images. Affected muscles showed heterogenous high signal intensity relative to the adjacent unaffected skeletal muscle on the T2- weighted images. The gadolinium-enhanced T1-weighted images showed diffuse inhomogeneous enhancement or peripheral rim enhancement of the affected muscles. The angiographic findings of the arterial injuries showed complete occlusion in three patients, severe stenosis in two patients and sluggish flow in one patient. Of these, the five patients with complete occlusion or severe stenosis on angiography showed non-perfused and non-viable areas of edematous muscle on

  1. The Electrostatic Wind Energy Converter : Electrical performance of a high voltage prototype

    NARCIS (Netherlands)

    Djairam, D.

    2008-01-01

    Wind energy is converted to electrical energy by letting the wind move charged particles against the direction of an electric field. The advantage of this type of conversion is that no rotational movement, which occurs in conventional wind turbines, is required. An electrostatic wind energy

  2. Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

    Science.gov (United States)

    Sadey, David J.; Taylor, Linda M.; Beach, Raymond F.

    2017-01-01

    The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as strategic thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of alternating current (AC) and direct current (DC) for power generation, transmission, and distribution. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power system, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of doubly-fed induction machines (DFIMs), which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the activity along with the system architecture, development status, and preliminary results.

  3. Incidence of stunned, hibernating and scarred myocardium in ischaemic cardiomyopathy

    International Nuclear Information System (INIS)

    Hernandez-Pampaloni, Miguel; Morita, Koichi; Dutka, David P.; Camici, Paolo G.; Bax, Jeroen J.

    2005-01-01

    Different criteria to identify residual viability in chronically dysfunctioning myocardium in patients with coronary artery disease (CAD) can be derived by the combined assessment of myocardial blood flow (MBF) and glucose utilisation (MRG) using positron emission tomography (PET). The aim of this study was to evaluate, in a large number of patients, the prevalence of these different patterns by purely quantitative means. One hundred and sixteen consecutive patients with ischaemic cardiomyopathy (LVEF ≤40%) underwent resting 2D echocardiography to assess regional contractile function (16-segment model). PET with 15 O-labelled water (H 2 15 O) and 18 F-fluorodeoxyglucose (FDG) was used to quantify MBF and MRG during hyperinsulinaemic euglycaemic clamp. Dysfunctional segments with normal MBF (≥0.6 ml min -1 g -1 ) were classified as stunned, and segments with reduced MBF ( -1 g -1 ) as hibernating if MRG was ≥0.25 μmol min -1 g -1 . Segments with reduced MBF and MRG -1 g -1 were classified as transmural scars and segments with reduced MBF and MRG between 0.20 and 0.25 μmol min -1 g -1 as non-transmural scars. Eight hundred and thirty-four (46%) segments were dysfunctional. Of these, 601 (72%) were chronically stunned, with 368 (61%) having normal MRG (0.47±0.20 μmol min -1 g -1 ) and 233 (39%) reduced MRG (0.16±0.05 μmol min -1 g -1 ). Seventy-four (9%) segments with reduced MBF had preserved MRG (0.40±0.18 μmol min -1 g -1 ) and were classified as hibernating myocardium. In addition, 15% of segments were classified as transmural and 4% as non-transmural scar. The mean MBF was highest in stunned myocardium (0.95±0.32 ml min -1 g -1 ), intermediate in hibernating myocardium and non-transmural scars (0.47±0.09 ml min -1 g -1 and 0.48±0.08 ml min -1 g -1 , respectively), and lowest in transmural scars (0.40±0.14 ml min -1 g -1 , P -1 g -1 vs 0.46±0.20 μmol min -1 g -1 , NS), and lowest in stunned myocardium with reduced MRG and transmural scars

  4. Constant voltage and constant current control implementation for electric vehicles (evs) wireless charger

    Science.gov (United States)

    Tampubolon, Marojahan; Pamungkas, Laskar; Hsieh, Yao Ching; Chiu, Huang Jen

    2018-04-01

    This paper presents the implementation of Constant Voltage (CV) and Constant Current (CC) control for a wireless charger system. A battery charging system needs these control modes to ensure the safety of the battery and the effectiveness of the charging system. Here, the wireless charger system does not employ any post-regulator stage to control the output voltage and output current of the charger. But, it uses a variable frequency control incorporated with a conventional PI control. As a result, the size and the weight of the system are reduced. This paper discusses the brief review of the SS-WPT, control strategy and implementation of the CV and CC control. Experimental hardware with 2kW output power has been performed and tested. The results show that the proposed CV and CC control method works well with the system.

  5. Modeling charge polarization voltage for large lithium-ion batteries in electric vehicles

    Directory of Open Access Journals (Sweden)

    Yan Jiang

    2013-06-01

    Full Text Available Purpose: Polarization voltage of the lithium-ion battery is an important parameter that has direct influence on battery performance. The paper aims to analyze the impedance characteristics of the lithium-ion battery based on EIS data. Design/methodology/approach: The effects of currents, initial SOC of the battery on charge polarization voltage are investigated, which is approximately linear function of charge current. The change of charge polarization voltage is also analyzed with the gradient analytical method in the SOC domain. The charge polarization model with two RC networks is presented, and parts of model parameters like Ohmic resistance and charge transfer impedance are estimated by both EIS method and battery constant current testing method. Findings: This paper reveals that the Ohmic resistance accounts for much contribution to battery total polarization compared to charge transfer impedance. Practical implications: Experimental results demonstrate the efficacy of the model with the proposed identification method, which provides the foundation for battery charging optimization. Originality/value: The paper analyzed the impedance characteristics of the lithium-ion battery based on EIS data, presented a charge polarization model with two RC networks, and estimated parameters like Ohmic resistance and charge transfer impedance.

  6. New Approach for High-Voltage Electrical Double-Layer Capacitors Using Vertical Graphene Nanowalls with and without Nitrogen Doping.

    Science.gov (United States)

    Chi, Yu-Wen; Hu, Chi-Chang; Shen, Hsiao-Hsuan; Huang, Kun-Ping

    2016-09-14

    Integrating various devices to achieve high-performance energy storage systems to satisfy various demands in modern societies become more and more important. Electrical double-layer capacitors (EDLCs), one kind of the electrochemical capacitors, generally provide the merits of high charge-discharge rates, extremely long cycle life, and high efficiency in electricity capture/storage, leading to a desirable device of electricity management from portable electronics to hybrid vehicles or even smart grid application. However, the low cell voltage (2.5-2.7 V in organic liquid electrolytes) of EDLCs lacks the direct combination of Li-ion batteries (LIBs) and EDLCs for creating new functions in future applications without considering the issue of a relatively low energy density. Here we propose a guideline, "choosing a matching pair of electrode materials and electrolytes", to effectively extend the cell voltage of EDLCs according to three general strategies. Based on the new strategy proposed in this work, materials with an inert surface enable to tolerate a wider potential window in commercially available organic electrolytes in comparison with activated carbons (ACs). The binder-free, vertically grown graphene nanowalls (GNW) and nitrogen-doped GNW (NGNW) electrodes respectively provide good examples for extending the upper potential limit of a positive electrode of EDLCs from 0.1 to 1.5 V (vs Ag/AgNO3) as well as the lower potential limit of a negative electrode of EDLCs from -2.0 V to ca. -2.5 V in 1 M TEABF4/PC (propylene carbonate) compared to ACs. This newly designed asymmetric EDLC exhibits a cell voltage of 4 V, specific energy of 52 Wh kg(-1) (ca. a device energy density of 13 Wh kg(-1)), and specific power of 8 kW kg(-1) and ca. 100% retention after 10,000 cycles charge-discharge, reducing the series number of EDLCs to enlarge the module voltage and opening the possibility for directly combining EDLCs and LIBs in advanced applications.

  7. RTE takes over Houilleres du Bassin de Lorraine's high voltage electricity network; RTE reprend le reseau electrique haute tension des Houilleres du Bassin de Lorraine

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-01

    Houilleres du Bassin de Lorraine (HBL) decided to sell their high voltage electricity network to RTE. This takeover by RTE, the French transmission system operator, corresponds to the public service mission entrusted to it by the law of February 10, 2000, concerning the rational distribution of an electricity service in France and the local servicing of customers through the public transmission system.

  8. Experimental and numerical study of impact of voltage fluctuate, flicker and power factor wave electric generator to local distribution

    Science.gov (United States)

    Hadi, Nik Azran Ab; Rashid, Wan Norhisyam Abd; Hashim, Nik Mohd Zarifie; Mohamad, Najmiah Radiah; Kadmin, Ahmad Fauzan

    2017-10-01

    Electricity is the most powerful energy source in the world. Engineer and technologist combined and cooperated to invent a new low-cost technology and free carbon emission where the carbon emission issue is a major concern now due to global warming. Renewable energy sources such as hydro, wind and wave are becoming widespread to reduce the carbon emissions, on the other hand, this effort needs several novel methods, techniques and technologies compared to coal-based power. Power quality of renewable sources needs in depth research and endless study to improve renewable energy technologies. The aim of this project is to investigate the impact of renewable electric generator on its local distribution system. The power farm was designed to connect to the local distribution system and it will be investigated and analyzed to make sure that energy which is supplied to customer is clean. The MATLAB tools are used to simulate the overall analysis. At the end of the project, a summary of identifying various voltage fluctuates data sources is presented in terms of voltage flicker. A suggestion of the analysis impact of wave power generation on its local distribution is also presented for the development of wave generator farms.

  9. Potentially damaging failure modes of high- and medium-voltage electrical equipment

    International Nuclear Information System (INIS)

    Hoy, H.C.

    1983-07-01

    The electrical equipment failures of both nuclear and nonnuclear public utilities were reviewed. Those failures that could pose an additional problem to surrounding and connected equipment were defined. The literature was searched; utilities, repair shops, and large electrical equipment users were contacted for failure information. The data were reviewed in detail, and failure modes were determined. Sample cascade failures are discussed. The failure rate of electrical equipment in utilities is historically quite low. Nuclear plants record too few failures to be statistically valid, but failures that have been recorded show that good design usually restricts the failure to a single piece of equipment

  10. Low-voltage electrical installations in medical buildings - clinical centres and hospitals

    Directory of Open Access Journals (Sweden)

    Simić Ninoslav

    2015-01-01

    Full Text Available This paper presents the observations collected during the testing of electrical installations in medical buildings. The details of the power supply, wiring systems and the implemented systems of protection against electric shocks are described. The causes of some faults during the exploitation of the facilities are presented through practical examples, and the specific problem caused by water leaking through the insulation of electrical installations is explained in detail. It is pointed out how important maintenance, monitoring and application of the latest standards in this area are, as well as adequate training of professional staff.

  11. Voltage-stabilised elastomers with increased relative permittivity and high electrical breakdown strength by means of phase separating binary copolymer blends of silicone elastomers

    DEFF Research Database (Denmark)

    A Razak, Aliff Hisyam; Yu, Liyun; Skov, Anne Ladegaard

    2017-01-01

    Increased electrical breakdown strength and increased dielectric permittivity of silicone-based dielectric elastomers are achieved by means of the addition of so-called voltage-stabilisers prepared from PDMS–PPMS copolymers as well as PDMS–PEG copolymers in order to compensate for the negative...... effect of softness on electrical stability of silicone elastomers. The voltage-stabilised elastomer, incorporating a high-permittivity PDMS–PEG copolymer, possesses increased relative permittivity, high electrical breakdown strength, excellent network integrity and low dielectric loss and paves the way...

  12. High voltage systems

    International Nuclear Information System (INIS)

    Martin, M.

    1991-01-01

    Industrial processes usually require electrical power. This power is used to drive motors, to heat materials, or in electrochemical processes. Often the power requirements of a plant require the electric power to be delivered at high voltage. In this paper high voltage is considered any voltage over 600 V. This voltage could be as high as 138,000 V for some very large facilities. The characteristics of this voltage and the enormous amounts of power being transmitted necessitate special safety considerations. Safety must be considered during the four activities associated with a high voltage electrical system. These activities are: Design; Installation; Operation; and Maintenance

  13. Effect of Voltage Measurement on the Quantitative Identification of Transverse Cracks by Electrical Measurements

    KAUST Repository

    Selvakumaran, Lakshmi; Lubineau, Gilles

    2016-01-01

    of the ply. Through the mesoscale relationship, the conductivity obtained from electrical tomography can be used as a measure of the transverse cracking density. Interpretation of this measure will be accurate provided the assumptions made during

  14. Effect of Voltage Measurement on the Quantitative Identification of Transverse Cracks by Electrical Measurements

    KAUST Repository

    Selvakumaran, Lakshmi

    2016-03-24

    Electrical tomography can be used as a structural health monitoring technique to identify different damage mechanisms in composite laminates. Previous work has established the link between transverse cracking density and mesoscale conductivity of the ply. Through the mesoscale relationship, the conductivity obtained from electrical tomography can be used as a measure of the transverse cracking density. Interpretation of this measure will be accurate provided the assumptions made during homogenization are valid. One main assumption of mesoscale homogenization is that the electric field is in the plane. Here, we test the validity of this assumption for laminates with varying anisotropy ratios and for different distances between the cracked ply and surface that is instrumented with electrodes. We also show the equivalence in electrical response between measurements from cracked laminates and their equivalent mesoscale counterparts. Finally, we propose some general guidelines on the measurement strategy for maximizing the accuracy of transverse cracks identification.

  15. Electric vehicles in low voltage residential grid: a danish case study

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Thøgersen, Paul

    2012-01-01

    Electric Vehicles (EVs) have gained large interest in the energy sector as a carrier to support clean transportation and green electricity. The potential to use battery storages of electric vehicles as a sink for excess electricity that may result from large integration of wind power, especially...... in countries like Denmark, is widely discussed and promoted. However, the wide-spread adoption of EVs requires the provision of intelligent grid and EV charging infrastructure. To analyse and understand the amount of EVs that could be integrated in the local distribution grids, within its existing capabilities......, is absolutely essential for the system operators to plan and implement the levels of grid reinforcement and intelligence required. This paper investigates the local grid limitations to accommodate large amount of EVs of sizable power ratings in residential areas. The case study applied in this paper uses...

  16. Carbon structures formation in low current high voltage electrical discharge in hydrocarbon vapours

    International Nuclear Information System (INIS)

    Sobczyk, A T; Jaworek, A

    2011-01-01

    The properties of carbon fibers and other carbon structures produced from hydrocarbon vapours decomposed in electrically generated plasma at atmospheric pressure are studied in this paper. The electrical discharge was generated between a stainless steel needle and a plate made of nickel alloy. The carbon fiber has grown at the tip of the needle electrode, while other microflower-like deposits were built at the plate. The physical properties of carbon fibers were investigated by SEM, Raman spectroscopy, XRD, and EDS methods.

  17. High voltage electric field effects on structure and biological characteristics of barley seeds

    Energy Technology Data Exchange (ETDEWEB)

    Khazaei, J. [Tehran Univ., Tehran (Iran, Islamic Republic of). Dept. of Agrotechnology, Univ. College of Abouraihan; Aliabadi, E. [Tehran Univ., Tehran (Iran, Islamic Republic of). Dept. of Crop Production Horticulture, Univ. College of Aburaihan; Shayegani, A.A. [Tehran Univ., Tehran (Iran, Islamic Republic of). Univ. College of Engineering

    2010-07-01

    Electric biostimulation of seeds is a pre-sowing treatment in which an electric field is applied to seeds to increase germination of non standard seeds. This paper reported on a study that examined the effects of AC electric field and exposure time on the structure and biological characteristics of barley seeds. The objective was to determine the potential to accelerate seed germination, plant growth and root development by the electric field strength and exposure time. Makooei cultivar barley seeds were used in this study. The effect of electric field strength (at 2, 4, 9, and 14 kV/m) and exposure time (at 15, 45, 80, and 150 min) on seed germination was studied along with height of seedling, length or root, height of stem, length of leaves, earliness, dry weight and wet weight of seedling. The treated seeds were stored for a month in a refrigerator at 5 degrees C prior to the germination experiments. The initial germination percent of the seed was 81 per cent. The treatment of barley seeds in an AC electric field had a positive effect on all investigated parameters. The germination percent of the treated seed increased to 94.5 per cent . The seeds exposed for long periods of time (45 to 150 min) showed better germination than the seeds exposed to lower exposure times. Dry and wet weights of seedling increased 143.4 per cent and 45.7 per cent, respectively.

  18. Radiation tests on selected electrical insulating materials for high-power and high voltage application

    International Nuclear Information System (INIS)

    Liptak, G.; Schuler, R.; Haberthuer, B.; Mueller, H.; Zeier, W.; Maier, P.; Schoenbacher, H.

    1985-01-01

    This report presents a comprehensive set of test results on the irradiation of insulating materials and systems used for the windings of rotating machines, dry-type transformers, and magnet coils. The materials were: Novolac, bisphenol-A, and cycloaliphatic types of epoxy; saturated and unsaturated polyesterimide; silicone, phenolic, and acrylic resins. The reinforcement consisted of glass mat, glass roving, glass cloth, mica paper, polyester mat, polyester roving, polyester cloth, aromatic polyamide paper, or combinations thereof. The materials were irradiated in an 8 MW pool reactor up to integrated doses of 10 8 Gy. On most samples, flexural properties were examined as recommended by IEC Standard 544. For tapes and varnishes, the breakdown voltage was measured. The adhesion of copper bars glued together with an epoxy resin was examined by means of a lap-shear test. A cupping test by means of the Erichsen apparatus was used to measure the flexibility of varnishes. The results are presented in tables and graphs for each of the materials tested. Those from mechanical tests show that the radiation resistance of composite resin-rich insulations depends not only on the base resin combination and the reinforcement material but, to a large degree, also on the adhesion between the two. It appears that better adhesion, and consequently higher radiation resistance, is obtained by special surface treatments of glass fibres. For laminates, higher radiation resistance is obtained with glass mat and resin combinations than with glass cloth as reinforcing materials. The breakdown voltage tests show that the application of mechanical stress to most irradiated samples causes the insulation layer to crack, resulting in lower dielectric strength. For a number of materials, the critical properties of flexural strength and breakdown voltage are above 50% of the initial value at doses between 10 7 and 10 8 Gy, i.e. a radiation index of 7 to 8 at 10 5 Gy/h. (orig.)

  19. Some problems relating to the transmission of electrical power at very high voltage

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, A

    1965-01-01

    Some of the technical and economic factors which influence the choice of a transmission system, particularly a very high voltage one, are discussed. The stability of transmission overvoltages at mains frequency and their control by means of compensating reactances is described. Overvoltages due to circuit-breaker operation and those of atmospheric origin, and appropriate protective devices, the behaviour of equipment at 750 kV, and problems of testing are included. Finally, the 735 kV network now being installed to carry 5300 MW of hydroelectric power 650 km from the Manicouagan River to Quebec and Montreal is described.

  20. Impact Study of Electric Vehicle (EV) Integration on Low Voltage (LV) Grids

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cha, Seung-Tae; Nielsen, Arne Hejde

    2012-01-01

    the single line diagram (SLD) of the LV grid. The demand profiles of end-users are determined by the end-user yearly consumption and avreaged demand profiles of different customer types in Denmark. Five charging scenarios have been tested using the developed LV grid. The first two charging scenarios are dumb....... The two charging power levels are 1 phase 16 A and 3 phase 16 A. The loading of the power components and voltage profile are analyzed to quantify the impact of the charging scenarios and charging power levels on LV grids....

  1. Electrical and structural R&D activities on high voltage dc solid insulator in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Pilan, N., E-mail: nicola.pilan@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Marcuzzi, D.; Rizzolo, A.; Grando, L.; Gambetta, G. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Rosa, S. Dalla [Umicore – Italbras S.p.A., Strada del Balsego, n.6, 36100 Vicenza (Italy); Kraemer, V.; Quirmbach, T. [FRIATEC Ceramics Division, Steinzeugstrasse 50, 68229 Mannheim (Germany); Chitarin, G. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Gobbo, R.; Pesavento, G. [DII, Università di Padova, v. Gradenigo 6/A, I-35131 Padova (Italy); De Lorenzi, A.; Lotto, L.; Rizzieri, R.; Fincato, M.; Romanato, L.; Trevisan, L.; Cervaro, V.; Franchin, L. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2015-10-15

    Highlights: • A thorough R&D activity on the MITICA post insulator prototypes is being carried out. • The design has been numerically verified considering both mechanical and electrical aspects. • Experimental validation has been started, with positive results in both involved fields. • Alternative design solutions thickness have been proposed and successfully tested. - Abstract: This paper describes the R&D work performed in support of the design of the alumina insulators for the MITICA Neutral Beam Injector. The ceramic insulators are critical elements, both from the structural and electrical point of view, of the 1 MV electrostatic accelerator of the MITICA injector, as they are required to sustain both the mechanical loads due to the cantilevered weight of the ion source and the high electric field between the accelerator grids. This paper presents the results of numerical simulations and experimental tests on prototypes that have been carried out to validate the insulator design under realistic operating conditions.

  2. Electrical and structural R&D activities on high voltage dc solid insulator in vacuum

    International Nuclear Information System (INIS)

    Pilan, N.; Marcuzzi, D.; Rizzolo, A.; Grando, L.; Gambetta, G.; Rosa, S. Dalla; Kraemer, V.; Quirmbach, T.; Chitarin, G.; Gobbo, R.; Pesavento, G.; De Lorenzi, A.; Lotto, L.; Rizzieri, R.; Fincato, M.; Romanato, L.; Trevisan, L.; Cervaro, V.; Franchin, L.

    2015-01-01

    Highlights: • A thorough R&D activity on the MITICA post insulator prototypes is being carried out. • The design has been numerically verified considering both mechanical and electrical aspects. • Experimental validation has been started, with positive results in both involved fields. • Alternative design solutions thickness have been proposed and successfully tested. - Abstract: This paper describes the R&D work performed in support of the design of the alumina insulators for the MITICA Neutral Beam Injector. The ceramic insulators are critical elements, both from the structural and electrical point of view, of the 1 MV electrostatic accelerator of the MITICA injector, as they are required to sustain both the mechanical loads due to the cantilevered weight of the ion source and the high electric field between the accelerator grids. This paper presents the results of numerical simulations and experimental tests on prototypes that have been carried out to validate the insulator design under realistic operating conditions.

  3. Optical and Electrical Performance of MOS-Structure Silicon Solar Cells with Antireflective Transparent ITO and Plasmonic Indium Nanoparticles under Applied Bias Voltage.

    Science.gov (United States)

    Ho, Wen-Jeng; Sue, Ruei-Siang; Lin, Jian-Cheng; Syu, Hong-Jang; Lin, Ching-Fuh

    2016-08-10

    This paper reports impressive improvements in the optical and electrical performance of metal-oxide-semiconductor (MOS)-structure silicon solar cells through the incorporation of plasmonic indium nanoparticles (In-NPs) and an indium-tin-oxide (ITO) electrode with periodic holes (perforations) under applied bias voltage. Samples were prepared using a plain ITO electrode or perforated ITO electrode with and without In-NPs. The samples were characterized according to optical reflectance, dark current voltage, induced capacitance voltage, external quantum efficiency, and photovoltaic current voltage. Our results indicate that induced capacitance voltage and photovoltaic current voltage both depend on bias voltage, regardless of the type of ITO electrode. Under a bias voltage of 4.0 V, MOS cells with perforated ITO and plain ITO, respectively, presented conversion efficiencies of 17.53% and 15.80%. Under a bias voltage of 4.0 V, the inclusion of In-NPs increased the efficiency of cells with perforated ITO and plain ITO to 17.80% and 16.87%, respectively.

  4. Optical and Electrical Performance of MOS-Structure Silicon Solar Cells with Antireflective Transparent ITO and Plasmonic Indium Nanoparticles under Applied Bias Voltage

    Directory of Open Access Journals (Sweden)

    Wen-Jeng Ho

    2016-08-01

    Full Text Available This paper reports impressive improvements in the optical and electrical performance of metal-oxide-semiconductor (MOS-structure silicon solar cells through the incorporation of plasmonic indium nanoparticles (In-NPs and an indium-tin-oxide (ITO electrode with periodic holes (perforations under applied bias voltage. Samples were prepared using a plain ITO electrode or perforated ITO electrode with and without In-NPs. The samples were characterized according to optical reflectance, dark current voltage, induced capacitance voltage, external quantum efficiency, and photovoltaic current voltage. Our results indicate that induced capacitance voltage and photovoltaic current voltage both depend on bias voltage, regardless of the type of ITO electrode. Under a bias voltage of 4.0 V, MOS cells with perforated ITO and plain ITO, respectively, presented conversion efficiencies of 17.53% and 15.80%. Under a bias voltage of 4.0 V, the inclusion of In-NPs increased the efficiency of cells with perforated ITO and plain ITO to 17.80% and 16.87%, respectively.

  5. Planning Future Electric Vehicle Central Charging Stations Connected to Low-Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Marra, Francesco; Træholt, Chresten; Larsen, Esben

    2012-01-01

    A great interest is recently paid to Electric Vehicles (EV) and their integration into electricity grids. EV can potentially play an important role in power system operation, however, the EV charging infrastructures have been only partly defined, considering them as limited to individual charging...... on their investment cost. Investigation on location and size of CCS is conducted, analyzing two LV grids of different capacity. The results enlighten that a public CCS should be preferably located in the range of 100 m from the transformer. The AC charging levels of 11 kW and 22 kW have the highest potential in LV...

  6. INFLUENCE OF SHOCK VOLTAGE FROM THE ELECTRIC DISCHARGE ON THE FATIGUE ENDURANCE OF CARBON STEEL IN WATER

    Directory of Open Access Journals (Sweden)

    I. O. Vakulenko

    2015-09-01

    Full Text Available Purpose. The research supposes the explanation of influence of stress impulses from an electrical discharge in water on the level of the limited endurance at a cyclic loading of the thermally work-hardened carbon steel. Methodology. Material for research was steel 45 (0,45 % carbon with сoncentration of chemical elements within the limits of steel composition. Specimens for tests are made as plates in 1 thick, width 15 and length 120-180 mm. The structural state of steel corresponded to quenching on a martensite from the normal temperatures of annealing and tempering at 300C, duration of 1 h. Microstructure was investigated with the use of electronic microscopy, the density of dislocations was estimated on the methods of X-ray analysis. Hardness was measured on the method of Rockwell (scale of «C». A cyclic loading was carried out in the conditions of symmetric bend on a tester «Saturn-10» at a temperature +20C. The treatment by shock voltage from the electrical discharge was carried out in water on setting of bath type «Iskra-23», used for cleaning of castings manufactures. Electric impulses were formed at 15-18 kV with energy of 10-12 kJ and amplitude of 1-2 GPа. Findings. As a result of processing pulses of a pressure wave of heat-strengthened steel 45 found the increase of endurance under the cyclic loading corresponds to an increased amount of accumulated dislocations on the fracture surface. The use of Coffin–Manson Equation allowed finding the decrease of deformation per cycle of loading as a result of arising stress from an electrical discharge in water. On the fracture surface (after pulse exposure was found the increased number of dislocations, located in different crystallographic systems, that is a testament to the rather complicated development of dislocation transformations in the structure of steel, which provide an increase of endurance at a fatigue. The increase of the limited endurance became as a result of impulsive

  7. Impact of plug-in electric vehicles on voltage unbalance in ...

    African Journals Online (AJOL)

    DR OKE

    unbalance in the three-phase distribution system, and also leads to the ... Accounting losses, charging such batteries means even higher energy usage from distribution network. .... electric vehicles and conventional internal combustion engine vehicles. ... The summary information of EV connection are shown as Table 1.

  8. CONSIDERATIONS FOR FAILURE PREVENTION IN AEROSPACE ELECTRICAL POWER SYSTEMS UTILIZING HIGHER VOLTAGES

    Science.gov (United States)

    2017-07-01

    exist to develop tests that mimic the aerospace environment. Testing and qualification requirements for hermetic components need to consider leakage ...containing significant amounts of water . Different parts of the flight cycle may also be critical for specific components. Open-box power electronics...60270 [A-3]. Specialized test systems have been developed to detect and characterize PD in electrical equipment at atmospheric pressures. Although

  9. Voltage Stability Control of Electrical Network Using Intelligent Load Shedding Strategy Based on Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    Houda Jouini

    2010-01-01

    Full Text Available As a perspective to ensure the power system stability and to avoid the vulnerability leading to the blackouts, several preventive and curative means are adopted. In order to avoid the voltage collapse, load shedding schemes represent a suitable action to maintain the power system service quality and to control its vulnerability. In this paper, we try to propose an intelligent load shedding strategy as a new approach based on fuzzy controllers. This strategy was founded on the calculation of generated power sensitivity degree related to those injected at different network buses. During the fault phase, fuzzy controller algorithms generate monitor vectors ensuring a precalculated load shedding ratio in the purpose to reestablish the power balance and conduct the network to a new steady state.

  10. Study on Communication Methods for Electric Power High-voltage Equipment Monitoring System

    Directory of Open Access Journals (Sweden)

    Jia Yu Chen

    2018-02-01

    Full Text Available Real-time monitoring of high-voltage equipment in substations is beneficial for early detection of faults. The use of wireless sensor networks to build monitoring system is an effective way, but the data collection is a difficult task. The author introduces a real-time monitoring system based on ZIGBEE and mobile communication technology. The system includes multiple monitoring points and terminal platforms. Each monitoring point consists of a number of sensor nodes to form a ZIGBEE network, detecting relevant parameters, coordinator node data collected one by one, known as linear transmission, and finally to the monitoring platform through the mobile communication network. This paper presents a fusion algorithm for monitoring cell data acquisition to reduce the amount of data uploaded to the base station. In addition, multi-hop routing algorithm based on opportunistic routing is proposed to balance network energy and improve network transmission rate and efficiency.

  11. The photovoltaic industry stunned; La filiere photovoltaique en etat de choc

    Energy Technology Data Exchange (ETDEWEB)

    Piro, P.

    2011-03-15

    In December 2010 the French authorities decided a 3-month moratory on any new project of photovoltaic installation (over 3 KWc) because of the huge number of demands that made the cost of the incentive measures soar in an unexpected manner. In March 2011 the moratory was lifted and the professionals have been stunned by the new conditions imposed to benefit from the preferential purchase tariffs of the electricity produced that are far less favourable than previously. The new tariff grid will be adjusted each term according to the volume of demands. While several thousand jobs are at stake, the professionals hope a reversal of the government position as France enters an electoral period. (A.C.)

  12. The principle of elaboration of the relay protection against short circuits between the closely placed phases of high voltage electrical line

    Directory of Open Access Journals (Sweden)

    Kiorsak M.

    2015-12-01

    Full Text Available The article is devoted to the elaboration of the principle of relay protection against short circuits between the closely placed phases of higher voltage electrical line with self-compensation, based on the six phase’s symmetrical components. It is shown that the unsymmetrical short circuits between the closely placed phases are characterized by appearance of zero and tertiary sequences of symmetrical components. This fact can be used to choose them for relay protection. The electrical basic circuits and formulas for calculation of the passive parameters of zero and tertiary filters of currents (voltages are done. It is presented the structural-functional basic circuit scheme for relay protection against short circuits between the closely placed phases of higher voltage electrical line with self-compensation.

  13. Effect of Electric Voltage and Current of X-ray Chamber on the Element inthe Zirconium Alloy Analysis X-ray by X-ray Fluorescence

    International Nuclear Information System (INIS)

    Yusuf-Nampira; Narko-Wibowo, L; Rosika-Krisnawati; Nudia-Barenzani

    2000-01-01

    The using of x-ray fluorescence in the chemical analysis depend heavilyon the parameters of x-ray chamber, for examples : electric voltage andelectric current. That parameter give effect in the result of determine ofSn, Cr, Fe and Ni in the zirconium alloy. 20 kV electric voltages are used onthe Mo x-ray chamber shall product x-ray of zirconium in the sample materialcan give effect in the stability of the analysis result (deviation more than5%). The result of analysis of elements in the zirconium alloy shall givedeviation less than 5% when using of electric voltage of the x-ray chamberless than 19 kV. The sensitivity of analysis can be reached by step upelectric current of x-ray chamber. (author)

  14. Electric-field-control of magnetic anisotropy of Co0.6Fe0.2B0.2/oxide stacks using reduced voltage

    Science.gov (United States)

    Kita, Koji; Abraham, David W.; Gajek, Martin J.; Worledge, D. C.

    2012-08-01

    We have demonstrated purely electrical manipulation of the magnetic anisotropy of a Co0.6Fe0.2B0.2 film by applying only 8 V across the CoFeB/oxide stack. A clear transition from in-plane to perpendicular anisotropy was observed. The quantitative relationship between interface anisotropy energy and the applied electric-field was determined from the linear voltage dependence of the saturation field. By comparing the dielectric stacks of MgO/Al2O3 and MgO/HfO2/Al2O3, enhanced voltage control was also demonstrated, due to the higher dielectric constant of the HfO2. These results suggest the feasibility of purely electrical control of magnetization with small voltage bias for spintronics applications.

  15. Adaptive approach for on-board impedance parameters and voltage estimation of lithium-ion batteries in electric vehicles

    Science.gov (United States)

    Farmann, Alexander; Waag, Wladislaw; Sauer, Dirk Uwe

    2015-12-01

    Robust algorithms using reduced order equivalent circuit model (ECM) for an accurate and reliable estimation of battery states in various applications become more popular. In this study, a novel adaptive, self-learning heuristic algorithm for on-board impedance parameters and voltage estimation of lithium-ion batteries (LIBs) in electric vehicles is introduced. The presented approach is verified using LIBs with different composition of chemistries (NMC/C, NMC/LTO, LFP/C) at different aging states. An impedance-based reduced order ECM incorporating ohmic resistance and a combination of a constant phase element and a resistance (so-called ZARC-element) is employed. Existing algorithms in vehicles are much more limited in the complexity of the ECMs. The algorithm is validated using seven day real vehicle data with high temperature variation including very low temperatures (from -20 °C to +30 °C) at different Depth-of-Discharges (DoDs). Two possibilities to approximate both ZARC-elements with finite number of RC-elements on-board are shown and the results of the voltage estimation are compared. Moreover, the current dependence of the charge-transfer resistance is considered by employing Butler-Volmer equation. Achieved results indicate that both models yield almost the same grade of accuracy.

  16. Inhibition of the voltage-dependent chloride channel of Torpedo electric organ by diisopropylfluorophosphate and its reversal by oximes

    International Nuclear Information System (INIS)

    Abalis, I.M.; Chiang, P.K.; Wirtz, R.A.; Andre, R.G.

    1986-01-01

    Diisopropylfluorophosphate (DFP), a potent organophosphate inhibitor of cholinesterases, was found to inhibit the specific binding of [ 35 S]t-butylbicyclophosphorothionate (TBPS), specific chloride channels ligand, to the electric organ membranes of Torpedo, with a Ki of 21 +/- 3 μM. The binding sites of [ 35 S]TBPS in the Torpedo membranes were found not to be GABA receptors or nicotinic acetylcholine receptors as previously described. Interestingly, a stimulation of the binding of [ 35 S]TBPS was observed in the presence of atropine and three oximes, monopyridinium oxime 2-PAM, bispyridinium bis-oxime TMB-4 and H-oxime HI-6. The maximal stimulation was 300-500% of control, after which, the stimulation was reversed at higher concentrations. The three oximes protected by more than 95% the inhibition by 1 mM DFP of the binding of [ 35 S]TBPS to the voltage-dependent chloride channel. However, atropine protected only 20% of the inhibited channel. These results, thus, suggest that the protection against the toxic effects of DFP or other anticholinesterase agents by the tested oximes may not be solely a result of the reactivation of cholinesterases but also the protection of the voltage-dependent chloride channel

  17. Wireless Power Supply via Coupled Magnetic Resonance for on-line Monitoring Wireless Sensor of High-voltage Electrical Equipment

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Yudi, Xiao

    2016-01-01

    On-line monitoring of high-voltage electrical equipment (HV-EE) aiming to detect faults effectively has become crucial to avoid serious accidents. Moreover, highly reliable power supplies are the key component for the wireless sensors equipped in such on-line monitoring systems. Therefore......, in this paper, the wireless power supply via coupled magnetic resonance (MR-WPS) is proposed for powering the wireless sensor and the associated wireless sensor solution is also proposed. The key specifications of the MR-WPS working in switchgear cabinet with a harsh operation environment are analyzed...... power is able to be delivered to the wireless sensor through the designed MR-WPS, and therefore the theoretical analysis and design is verified....

  18. Rapid formation of electric field profiles in repetitively pulsed high-voltage high-pressure nanosecond discharges

    International Nuclear Information System (INIS)

    Ito, Tsuyohito; Kobayashi, Kazunobu; Hamaguchi, Satoshi; Czarnetzki, Uwe

    2010-01-01

    Rapid formation of electric field profiles has been observed directly for the first time in nanosecond narrow-gap parallel-plate discharges at near-atmospheric pressure. The plasmas examined here are of hydrogen, and the field measurement is based on coherent Raman scattering (CRS) by hydrogen molecules. Combined with the observation of spatio-temporal light emission profiles by a high speed camera, it has been found that the rapid formation of a high-voltage thin cathode sheath is accompanied by fast propagation of an ionization front from a region near the anode. Unlike well-known parallel-plate discharges at low pressure, the discharge formation process at high pressure is almost entirely driven by electron dynamics as ions and neutral species are nearly immobile during the rapid process. (fast track communication)

  19. AN EVALUATION OF CONDITION MONITORING TECHNIQUES FOR LOW-VOLTAGE ELECTRIC CABLES

    International Nuclear Information System (INIS)

    LOFARO, R.J.; GROVE, E.; SOO, P.

    2000-01-01

    Aging of systems and components in nuclear power plants is a well known occurrence that must be managed to ensure the continued safe operation of these plants. Much of the degradation due to aging is controlled through periodic maintenance and/or component replacement. However, there are components that do not receive periodic maintenance or monitoring once they are installed; electric cables are such a component. To provide a means of monitoring the condition of electric cables, research is ongoing to evaluate promising condition monitoring (CM) techniques that can be used in situ to monitor cable condition and predict remaining life. While several techniques are promising, each has limitations that must be considered in its application. This paper discusses the theory behind several of the promising cable CM techniques being studied, along with their effectiveness for monitoring aging degradation in typical cable insulation materials, such as cross-linked polyethylene and ethylene propylene rubber. Successes and limitations of each technique are also presented

  20. OPTIMAL CHARGING OF ELECTRICAL VEHICLES IN THE SMART CITY FOR LOSS MINIMIZATION AND VOLTAGE IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    Adrian Toni Radu

    2017-06-01

    Full Text Available The world is two-thirds of the way through a century-long cycle of rapid urbanisation, at the end of which more than 70% of people will live in cities (World Health Organization, 2014. The urban transformation has become a major contributor to economic, demographic, social and environmental change. Electric vehicles (EVs have become increasingly popular over the last few years and are considered as an important means to mitigate air pollution problems in big cities around the world. With their onboard batteries, EVs also present an opportunity to serve as a demand response tool in supporting future smart grid where there is usually high penetration level of renewable energy (RE sources. In this paper, we consider the coordinated charging control of electrical vehicles in the charging stations. The goals are to illustrate how the integration of EVs at the urban area improve the overall load schedule of the distribution network.

  1. Uninterruptible power supply model of independent voltage inverter of NPP electrical equipment

    International Nuclear Information System (INIS)

    Rozhkov, V.V.; Ajdaralieva, V.Eh.

    2010-01-01

    A package of main transforming units models of advanced uninterruptible power supply systems of NPP electrical equipment was developed. The package of models allows investigating the basic modes of uninterruptible power supply systems operation by computer modeling. Simulation results were presented. Recommendations on choice of parameters of power circuit elements as well as on diagnostics and adjustment of regulators of converters control systems were given [ru

  2. [Changes of platelet rheological behavior and the interventional effects of ulinastatin in rats with high-voltage electrical burns].

    Science.gov (United States)

    Zhang, Q F; Li, Y; Feng, J K; Xu, Y F; Tu, L L

    2017-12-20

    Objective: To explore the influence of high-voltage electrical burns on the number of platelet aggregation, β-thromboglobulin (β-TG) and platelet factor 4 (PF-4) and the interventional effects of ulinastatin in rats with high-voltage electrical burns. Methods: A total of 240 Sprague-Dawley rats were divided into sham injury (SI) group, simple electrical burn (SEB) group, normal saline (NS) group, and ulinastatin (UTI) group according to the random number table, with 60 rats in each group. The electrical current was applied to the outside proximal part of left forelimb of rats and exited from the outside proximal part of right hind limb of rats. Rats in groups SEB, NS, and UTI were inflicted with high-voltage electrical burn wounds of 1 cm×1 cm at current entrances and exits, with the voltage regulator and experimental transformer. Rats in group SI were sham injured through connecting the same equipments without electricity. At 2 min post injury, rats in group NS were intraperitoneally injected with 2 mL/kg NS, and rats in group UTI were intraperitoneally injected with 2×10(4) U/kg UTI of 10 g/L. At 15 min before injury and 5 min, 1 h, 2 h, 4 h, 8 h post injury, 10 rats in each group were selected to collect 5-7 mL blood of heart respectively. Blood of 0.05 mL were collected to make fresh blood smear for observing the number of platelet aggregation, and serum were separated from the remaining blood to determine content of β-TG and PF-4 with enzyme-linked immunosorbent assay. Data were processed with analysis of factorial design of variance, student-Newman-Keuls test, Kruskal-Wallis H test, Wilcoxon rank sum test, and Bonferroni correction. Results: (1) At 15 min before injury, the numbers of platelet aggregation of rats were close among groups SI, SEB, NS and UTI (5.9±1.2, 5.8±1.2, 5.9±1.3, 5.9±1.1, respectively, with P values above 0.05). At 5 min, 1 h, 2 h, 4 h, 8 h post injury, the numbers of platelet aggregation of rats in group SEB were 57.2±16.3, 59

  3. Advanced medium-voltage bidirectional dc-dc conversion systems for future electric energy delivery and management systems

    Science.gov (United States)

    Fan, Haifeng

    2011-12-01

    The distributed renewable energy generation and utilization are constantly growing, and are expected to be integrated with the conventional grid. The growing pressure for innovative solutions will demand power electronics to take an even larger role in future electric energy delivery and management systems, since power electronics are required for the conversion and control of electric energy by most dispersed generation systems Furthermore, power electronics systems can provide additional intelligent energy management, grid stability and power quality capabilities. Medium-voltage isolated dc-dc converter will become one of the key interfaces for grid components with moderate power ratings. To address the demand of medium voltage (MV) and high power capability for future electric energy delivery and management systems, the power electronics community and industry have been reacting in two different ways: developing semiconductor technology or directly connecting devices in series/parallel to reach higher nominal voltages and currents while maintaining conventional converter topologies; and by developing new converter topologies with traditional semiconductor technology, known as multilevel converters or modular converters. The modular approach uses the well-known, mature, and cheaper power semiconductor devices by adopting new converter topologies. The main advantages of the modular approach include: significant improvement in reliability by introducing desired level of redundancy; standardization of components leading to reduction in manufacturing cost and time; power systems can be easily reconfigured to support varying input-output specifications; and possibly higher efficiency and power density of the overall system. Input-series output-parallel (ISOP) modular configuration is a good choice to realize MV to low voltage (LV) conversion for utility application. However, challenges still remain. First of all, for the high-frequency MV utility application, the low

  4. Vibration of high-voltage electric machines with rotors on rolling bearings

    Science.gov (United States)

    Shekyan, H. G.; Gevorgyan, A. V.

    2018-04-01

    The paper presents an investigation of vibrational activity of electric machines due to high-harmonic vibrational loadings. It is shown that the vibrational loadings experienced by bearings may result in the interruption of their normal operation and even take them out of action. Therefore, the values of the vibrational speed-up leading to high harmonics are factors determining the admissible dynamic loading on the bearings. In the paper, an attempt is made to consider the factors which result in origination of high harmonics and to illustrate methods for their smoothing.

  5. A Smoothing Technique for the Multifractal Analysis of a Medium Voltage Feeders Electric Current

    Science.gov (United States)

    de Santis, Enrico; Sadeghian, Alireza; Rizzi, Antonello

    2017-12-01

    The current paper presents a data-driven detrending technique allowing to smooth complex sinusoidal trends from a real-world electric load time series before applying the Detrended Multifractal Fluctuation Analysis (MFDFA). The algorithm we call Smoothed Sort and Cut Fourier Detrending (SSC-FD) is based on a suitable smoothing of high power periodicities operating directly in the Fourier spectrum through a polynomial fitting technique of the DFT. The main aim consists of disambiguating the characteristic slow varying periodicities, that can impair the MFDFA analysis, from the residual signal in order to study its correlation properties. The algorithm performances are evaluated on a simple benchmark test consisting of a persistent series where the Hurst exponent is known, with superimposed ten sinusoidal harmonics. Moreover, the behavior of the algorithm parameters is assessed computing the MFDFA on the well-known sunspot data, whose correlation characteristics are reported in literature. In both cases, the SSC-FD method eliminates the apparent crossover induced by the synthetic and natural periodicities. Results are compared with some existing detrending methods within the MFDFA paradigm. Finally, a study of the multifractal characteristics of the electric load time series detrendended by the SSC-FD algorithm is provided, showing a strong persistent behavior and an appreciable amplitude of the multifractal spectrum that allows to conclude that the series at hand has multifractal characteristics.

  6. Preventive maintenance basis: Volume 10 -- High voltage electric motors (5 kV and greater). Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-07-01

    US nuclear plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This report provides an overview of the PM Basis project and describes use of the PM Basis database. Volume 10 of the report provides a program of PM tasks suitable for application to high voltage (5kV and greater) electric motors in nuclear power plants. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs. Reactor Coolant Pumps motors (RCP's) are not excluded from this report in so far as good PM practices for motors of the appropriate class are concerned. However, the special auxiliary equipment normally associated with RCP's has not been included. Consequently, this report does not provide a complete PM program for RCP's. Industry and vendor programs for RCP's should be consulted for complete definition of RCP motor PM programs

  7. Hypothermic stunning of green sea turtles in a western Gulf of Mexico foraging habitat.

    Directory of Open Access Journals (Sweden)

    Donna J Shaver

    Full Text Available Texas waters provide one of the most important developmental and foraging habitats for juvenile green turtles (Chelonia mydas in the western Gulf of Mexico, but hypothermic stunning is a significant threat and was the largest cause of green turtle strandings in Texas from 1980 through 2015; of the 8,107 green turtles found stranded, 4,529 (55.9% were victims of hypothermic stunning. Additionally, during this time, 203 hypothermic stunned green turtles were found incidentally captured due to power plant water intake entrapment. Overall, 63.9% of 4,529 hypothermic stunned turtles were found alive, and 92.0% of those survived rehabilitation and were released. Numbers of green turtles recorded as stranded and as affected by hypothermic stunning increased over time, and were most numerous from 2007 through 2015. Large hypothermic stunning events (with more than 450 turtles documented occurred during the winters of 2009-2010, 2010-2011, 2013-2014, and 2014-2015. Hypothermic stunning was documented between November and March, but peaked at various times depending on passage of severe weather systems. Hypothermic stunning occurred state-wide, but was most prevalent in South Texas, particularly the Laguna Madre. In the Laguna Madre, hypothermic stunning was associated with an abrupt drop in water temperatures strong northerly winds, and a threshold mean water temperature of 8.0°C predicted large turtle hypothermic stunning events. Knowledge of environmental parameters contributing to hypothermic stunning and the temporal and spatial distribution of turtles affected in the past, can aid with formulation of proactive, targeted search and rescue efforts that can ultimately save the lives of many affected individuals, and aid with recovery efforts for this bi-national stock. Such rescue efforts are required under the U.S. Endangered Species Act and respond to humanitarian concerns of the public.

  8. Two-Stage Electric Vehicle Charging Coordination in Low Voltage Distribution Grids

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2014-01-01

    ). Being a sizable rated element, electric vehicles (EVs) can offer a great deal of demand flexibility in future intelligent grids. This paper first investigates and analyzes driving pattern and charging requirements of EVs. Secondly, a two-stage charging algorithm, namely local adaptive control...... encompassed by a central coordinative control, is proposed to realize the flexibility offered by EV. The local control enables adaptive charging; whereas the central coordinative control prepares optimized charging schedules. Results from various scenarios show that the proposed algorithm enables significant......Increased environmental awareness in the recent years has encouraged rapid growth of renewable energy sources (RESs); especially solar PV and wind. One of the effective solutions to compensate intermittencies in generation from the RESs is to enable consumer participation in demand response (DR...

  9. Effect of electric field in the characterization of pultruded GFRP boron-free composite insulator for the extra high voltage by the ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hissae; Silva Junior, Edmilson Jose; Shinohara, Armando Hideki [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Xavier, Gustavo Jose Vasconcelos [CHESF, Recife, PE (Brazil); Costa, Edson Guedes [Universidade Federal de Campina Grande (UFCG), PB (Brazil); Lott Neto, Henrique Batista Duffles Teixeira; Britto, Paulo Roberto Ranzan; Fontan, Marcio A.B. [Sistema de Transmissao do Nordeste S.A., Recife, PE (Brazil)

    2016-07-01

    Full text: The pultruded boron-free glass fiber reinforced polymer (GFRP) composite has been widely used material for the electrical insulators in the high, extra and ultra high voltage overhead lines worldwide. In terms of design, the composite insulator has a highly complex geometry and large size. Aging of materials begin as soon as the insulators start their operation due to the strong electric field, mechanical load due to the weight of conductor cables, environment, corona discharge, generation of acids, and as a result, GFRP can fail mechanically by the stress corrosion crack (SCC) and electrical breakdown known as flashover. In order to mitigate the mechanical and electrical failures, the insulators in the field are frequently monitored by visual inspection, infrared thermography, UV detection, variation of measurement of distribution of electric field variation. However, new technologies for characterization and inspection of the composite insulator in the field are required for reliable operation. Imaging characterization using ionizing radiation (X-ray or g-ray) is an interesting technique, however, it can reduce drastically breakdown voltage due to the Townsend discharge, which free electrons are accelerated by an electric field, collide with gas molecules of air, and free additional electrons resulting in an avalanche multiplication that allows an electrical conduction through the air. In this study, in order to evaluate the potential application of ionization radiation for characterization of composite insulator under electric field, testing were conducted in high voltage laboratory by applying voltages up to 640 kV and varying radiation area of the composite insulator. As a result, even though there was an occurrence of flame on Imaging Plate (IP) detector case when it was located near the phase, corona discharge, but no breakdown discharge (flashover) occurred and high quality imaging of radiography could be obtained when X-ray source was employed

  10. Technological Aspects: High Voltage

    International Nuclear Information System (INIS)

    Faircloth, D C

    2013-01-01

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered. (author)

  11. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D.C.

    2013-12-16

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  12. Higher success rate with transcranial electrical stimulation of motor-evoked potentials using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery.

    Science.gov (United States)

    Shigematsu, Hideki; Kawaguchi, Masahiko; Hayashi, Hironobu; Takatani, Tsunenori; Iwata, Eiichiro; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Tanaka, Yuu; Tanaka, Yasuhito

    2017-10-01

    During spine surgery, the spinal cord is electrophysiologically monitored via transcranial electrical stimulation of motor-evoked potentials (TES-MEPs) to prevent injury. Transcranial electrical stimulation of motor-evoked potential involves the use of either constant-current or constant-voltage stimulation; however, there are few comparative data available regarding their ability to adequately elicit compound motor action potentials. We hypothesized that the success rates of TES-MEP recordings would be similar between constant-current and constant-voltage stimulations in patients undergoing spine surgery. The objective of this study was to compare the success rates of TES-MEP recordings between constant-current and constant-voltage stimulation. This is a prospective, within-subject study. Data from 100 patients undergoing spinal surgery at the cervical, thoracic, or lumbar level were analyzed. The success rates of the TES-MEP recordings from each muscle were examined. Transcranial electrical stimulation with constant-current and constant-voltage stimulations at the C3 and C4 electrode positions (international "10-20" system) was applied to each patient. Compound muscle action potentials were bilaterally recorded from the abductor pollicis brevis (APB), deltoid (Del), abductor hallucis (AH), tibialis anterior (TA), gastrocnemius (GC), and quadriceps (Quad) muscles. The success rates of the TES-MEP recordings from the right Del, right APB, bilateral Quad, right TA, right GC, and bilateral AH muscles were significantly higher using constant-voltage stimulation than those using constant-current stimulation. The overall success rates with constant-voltage and constant-current stimulations were 86.3% and 68.8%, respectively (risk ratio 1.25 [95% confidence interval: 1.20-1.31]). The success rates of TES-MEP recordings were higher using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery. Copyright © 2017

  13. Military Curricula for Vocational & Technical Education. Basic Electricity and Electronics Individualized Learning System. CANTRAC A-100-0010. Module Five: Relationships of Current, Voltage, and Resistance. Study Booklet.

    Science.gov (United States)

    Chief of Naval Education and Training Support, Pensacola, FL.

    This individualized learning module on the relationships of current, voltage, and resistance is one in a series of modules for a course in basic electricity and electronics. The course is one of a number of military-developed curriculum packages selected for adaptaticn to vocational instructional and curriculum development in a civilian setting.…

  14. Evaluation of the effectiveness of neurofeedback in the reduction of Posttraumatic stress disorder (PTSD in a patient following high-voltage electric shock with the use of ERPs

    Directory of Open Access Journals (Sweden)

    Anna Chrapusta

    2015-09-01

    Chronic PTSD developed within the patient as a result of a high-voltage electric burn. The application of a method of therapy (neurofeedback resulted in the withdrawal of the syndrome symptoms. ERPs in a GO/NOGO task can be used to plan neurofeedback and in the assessment of functional brain changes induced by neurotherapeutic programmes. Funds Collection: Private sources.

  15. Collapse and pull - down analysis of high voltage electricity transmission towers subjected to cyclonic wind

    International Nuclear Information System (INIS)

    Ahmed, Ammar; Arthur, Craig; Edwards, Mark

    2010-01-01

    Bulk electricity transmission lines are linear assets that can be very exposed to wind effects, particularly where they traverse steep topography or open coastal terrain in cyclonic regions. Interconnected nature of the lattice type towers and conductors also, present complex vulnerabilities. These relate to the direction of wind attack to the conductors and the cascading failure mechanisms in which the failure of a single tower has cascading effects on neighbouring towers. Such behaviour is exacerbated by the finely tuned nature of tower design which serves to minimize cost and reserve strength at design wind speeds. There is a clear need to better quantify the interdependent vulnerabilities of these critical infrastructure assets in the context of the severe wind hazard. This paper presents a novel methodology developed for the Critical Infrastructure Protection Modelling and Analysis (CIPMA) capability for assessing local wind speeds and the likelihood of tower failure for a range of transmission tower and conductor types. CIPMA is a program managed by the Federal Attorney-General's Department and Geoscience Australia is leading the technical development. The methodology then involves the development of heuristically derived vulnerability models that are consistent with Australian industry experience and full-scale static tower testing results, considering isolated tower loss along with three interdependent failure mechanisms to give overall likelihoods of failure.

  16. A new humane method of stunning broilers using low atmospheric pressure

    Science.gov (United States)

    This research project evaluated an alternative method of controlled atmosphere stunning of commercial broilers to induce anoxia utilizing a vacuum pump to reduce the oxygen tension, low atmospheric pressure stun (LAPS). A custom built 2 cage-module system (holding a total of 600 broilers each) with...

  17. The effect of stress, applied immediately before stunning, on pork quality

    NARCIS (Netherlands)

    Wal, van der P.G.; Engel, B.; Reimert, H.G.M.

    1999-01-01

    The effect on meat quality characteristics of stress, applied during a short period just before stunning, was studied on slaughterpigs (113 boars, 85 gilts). Sexes were kept separately and only pigs that had been stunned correctly were included. Aggressive behaviour during lairage occurred more

  18. Stunning and killing of farmed fish: How to put it into pratice?

    NARCIS (Netherlands)

    Vis, van de J.W.; Abbink, W.; Lambooij, B.; Bracke, M.B.M.

    2014-01-01

    In this article an approach is presented to implement stunning and killing of farmed fish in practice. First, in a laboratory setting, the conditions need to be established to achieve an effective stun without causing avoidable distress and discomfort. Product quality is evaluated to assess the

  19. Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source

    International Nuclear Information System (INIS)

    Sulaeman, M. Y.; Widita, R.

    2014-01-01

    Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20–100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of −1.5 kV with falltime 3 ns and risetime 15 ns into a 50Ω load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation

  20. The effect of the variable frequency drive of the CNC roll grinding machine on the operation of other devices in low-voltage electrical installation

    Directory of Open Access Journals (Sweden)

    Simić Ninoslav

    2016-01-01

    Full Text Available This paper presents one of the observations that have been collected during the years of testing of electrical installations. A typical case from industrial plant in which are installed loads with variable frequency regulation is analyzed. We propose a simple way by measuring the frequency of the voltage in the objects, to establish the existence of possible irregularities in the operation of the individual units and analyze the influence of the current and voltage signal shape of one load to the work of other loads in the plant. The need for verification of electrical installations immediately upon receipt and installation of electrical equipment is emphasized and the use of the latest standards in the design and selection of equipment, in order to avoid unplanned expenses is recommended.

  1. An implementation of particle swarm optimization to evaluate optimal under-voltage load shedding in competitive electricity markets

    Science.gov (United States)

    Hosseini-Bioki, M. M.; Rashidinejad, M.; Abdollahi, A.

    2013-11-01

    Load shedding is a crucial issue in power systems especially under restructured electricity environment. Market-driven load shedding in reregulated power systems associated with security as well as reliability is investigated in this paper. A technoeconomic multi-objective function is introduced to reveal an optimal load shedding scheme considering maximum social welfare. The proposed optimization problem includes maximum GENCOs and loads' profits as well as maximum loadability limit under normal and contingency conditions. Particle swarm optimization (PSO) as a heuristic optimization technique, is utilized to find an optimal load shedding scheme. In a market-driven structure, generators offer their bidding blocks while the dispatchable loads will bid their price-responsive demands. An independent system operator (ISO) derives a market clearing price (MCP) while rescheduling the amount of generating power in both pre-contingency and post-contingency conditions. The proposed methodology is developed on a 3-bus system and then is applied to a modified IEEE 30-bus test system. The obtained results show the effectiveness of the proposed methodology in implementing the optimal load shedding satisfying social welfare by maintaining voltage stability margin (VSM) through technoeconomic analyses.

  2. The anti-biofouling behavior of high voltage pulse electric field (HPEF) mediated by carbon fiber composite coating in seawater.

    Science.gov (United States)

    Feng, Tiantian; Wu, Jinyi; Chai, Ke; Yang, Pengpeng

    2018-04-25

    One of the most important research areas in the marine industry is to investigate new and effective anti-biofouling technologies. In this study, high voltage pulse electric field (HPEF) mediated by carbon fiber (CF) composite coating was utilized to prevent the fouling of bacteria, microalgae and barnacle larvae in seawater. The plate count, 2, 3, 5-triphenyl-tetrazolium chloride (TTC) reduction assay and neutral red (NR) staining and larval motility detection showed that the inactivation rates were at the highest levels, which reached 99.1%, 99.9%, 99.7%, 98.7% and 85% respectively for Pseudomonas sp., Vibrio sp., iron bacteria, Navicula sp. and the second stage nauplii of Balanus reticulatus, under the HPEF with 19 kV pulse amplitude, 23.15 kHz frequency and 0.5 duty cycle. The field-emission scanning electron microscopy (FE-SEM) of Navicula sp. revealed that the HPEF brought about the cell lysis and the cell organic matter release on the coating, which could be the mechanism of the inactivation by the HPEF. Additionally, the FE-SEM and Raman spectroscopy indicated that the HPEF hardly damaged the coating. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. High resolution separations of charge variants and disulfide isomers of monoclonal antibodies and antibody drug conjugates using ultra-high voltage capillary electrophoresis with high electric field strength.

    Science.gov (United States)

    Henley, W Hampton; He, Yan; Mellors, J Scott; Batz, Nicholas G; Ramsey, J Michael; Jorgenson, James W

    2017-11-10

    Ultra-high voltage capillary electrophoresis with high electric field strength has been applied to the separation of the charge variants, drug conjugates, and disulfide isomers of monoclonal antibodies. Samples composed of many closely related species are difficult to resolve and quantify using traditional analytical instrumentation. High performance instrumentation can often save considerable time and effort otherwise spent on extensive method development. Ideally, the resolution obtained for a given CE buffer system scales with the square root of the applied voltage. Currently available commercial CE instrumentation is limited to an applied voltage of approximately 30kV and a maximum electric field strength of 1kV/cm due to design limitations. The instrumentation described here is capable of safely applying potentials of at least 120kV with electric field strengths over 2000V/cm, potentially doubling the resolution of the best conventional CE buffer/capillary systems while decreasing analysis time in some applications. Separations of these complex mixtures using this new instrumentation demonstrate the potential of ultra-high voltage CE to identify the presence of previously unresolved components and to reduce analysis time for complex mixtures of antibody variants and drug conjugates. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Effects of high voltage electrical stimulation on the rate of pH decline, meat quality and color stability in chilled beef carcasses

    OpenAIRE

    Mombeni, Ehsan Gharib; Mombeini, Manoochehr Gharib; Figueiredo, Lucas Chaves; Siqueira, Luciano Soares Jacintho; Dias, Debora Testoni

    2013-01-01

    Objective: To determine the effects of high voltage electrical stimulation (HVES, 800 Voltage) on rapid decreases in pH values and improvements in meat quality. Methods: A total of 50 beef carcasses were applied, divided into two groups, one as a control and another for HVES. Meat quality was evaluated based on M. longissimus dorsi by examining pH and temperature levels at 1, 2, 5, 10 and 24 h, while color stability was examined seven days after slaughter. Results: HVES decreased the pH...

  5. Hard- and software of real time simulation tools of Electric Power System for adequate modeling power semiconductors in voltage source convertor based HVDC and FACTS

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2014-01-01

    Full Text Available The motivation of the presented research is based on the needs for development of new methods and tools for adequate simulation of Flexible Alternating Current Transmission System (FACTS devices and High Voltage Direct Current Transmission (HVDC system as part of real electric power systems (EPS. For that, a hybrid approach for advanced simulation of the FACTS and HVDC based on Voltage Source is proposed. The presented simulation results of the developed hybrid model of VSC confirm the achievement of the desired properties of the model and the effectiveness of the proposed solutions.

  6. Automatic voltage imbalance detector

    Science.gov (United States)

    Bobbett, Ronald E.; McCormick, J. Byron; Kerwin, William J.

    1984-01-01

    A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

  7. Pharmacologic stress-induced stunning: evaluation with quantitative gated SPECT

    International Nuclear Information System (INIS)

    Chun, K. A.; Cho, I. H.; Won, K. J.; Lee, H. W.

    2000-01-01

    The after-effect of pharmacologic stress (adenosine) on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated after pharmacologic stress with Tl-201 and 99m Tc-MIBI SPECT using an automated program in 153 subjects. The subjects were grouped as follows: 1) Tl-201 group (n=35, male 18, female 17, mean age: 58 years); normal scan (n=24), ischemia (n=8) and infarction (n=3). 2) 99m Tc-MIBI group (n=118, male 60, female 58, mean age: 62 years); normal scan (n=73), ischemia (n=20) and infarction (n=25) based on the interpretation of perfusion images. All patients were in sinus rhythm during the study. 1)Tl-201 group; In patients with ischemia (the mean time interval between injection and acquisition is 12.3 min), post-stress LVEF was significantly depressed after adenosine infusion (51.2 ± 6.3% vs 59.8± 8.2%, p 99m Tc-MIBI group; In patients with ischemia (the mean time interval between injection and acquisition is 80 min), post-stress LVEF was significantly depressed after adenosine infusion (p<0.001) and ΔLVEF was 5.1%. Eight patients (40%) showed an increase in LVEF greater than 5% from poststress to rest. Poststress ESV (37.1±17.3 ml) was significantly higher than ESV (31.3±15.5 ml, p<0.001) at rest, but no significant difference in EDV. These results showed that pharmacologic stress induced stunning is well noted in the early quantitative gated SPECT in ischemic patients and also observed in the delayed gated SPECT, even though the rate of stunning is less than the early SPECT

  8. Simulating Small-Scale Experiments of In-Tunnel Airblast Using STUN and ALE3D

    Energy Technology Data Exchange (ETDEWEB)

    Neuscamman, Stephanie [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Glenn, Lewis [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schebler, Gregory [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McMichael, Larry [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Glascoe, Lee [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-09-12

    This report details continuing validation efforts for the Sphere and Tunnel (STUN) and ALE3D codes. STUN has been validated previously for blast propagation through tunnels using several sets of experimental data with varying charge sizes and tunnel configurations, including the MARVEL nuclear driven shock tube experiment (Glenn, 2001). The DHS-funded STUNTool version is compared to experimental data and the LLNL ALE3D hydrocode. In this particular study, we compare the performance of the STUN and ALE3D codes in modeling an in-tunnel airblast to experimental results obtained by Lunderman and Ohrt in a series of small-scale high explosive experiments (1997).

  9. Image registration algorithm for high-voltage electric power live line working robot based on binocular vision

    Science.gov (United States)

    Li, Chengqi; Ren, Zhigang; Yang, Bo; An, Qinghao; Yu, Xiangru; Li, Jinping

    2017-12-01

    In the process of dismounting and assembling the drop switch for the high-voltage electric power live line working (EPL2W) robot, one of the key problems is the precision of positioning for manipulators, gripper and the bolts used to fix drop switch. To solve it, we study the binocular vision system theory of the robot and the characteristic of dismounting and assembling drop switch. We propose a coarse-to-fine image registration algorithm based on image correlation, which can improve the positioning precision of manipulators and bolt significantly. The algorithm performs the following three steps: firstly, the target points are marked respectively in the right and left visions, and then the system judges whether the target point in right vision can satisfy the lowest registration accuracy by using the similarity of target points' backgrounds in right and left visions, this is a typical coarse-to-fine strategy; secondly, the system calculates the epipolar line, and then the regional sequence existing matching points is generated according to neighborhood of epipolar line, the optimal matching image is confirmed by calculating the similarity between template image in left vision and the region in regional sequence according to correlation matching; finally, the precise coordinates of target points in right and left visions are calculated according to the optimal matching image. The experiment results indicate that the positioning accuracy of image coordinate is within 2 pixels, the positioning accuracy in the world coordinate system is within 3 mm, the positioning accuracy of binocular vision satisfies the requirement dismounting and assembling the drop switch.

  10. Nanosecond pulsed electric fields depolarize transmembrane potential via voltage-gated K+, Ca2+ and TRPM8 channels in U87 glioblastoma cells.

    Science.gov (United States)

    Burke, Ryan C; Bardet, Sylvia M; Carr, Lynn; Romanenko, Sergii; Arnaud-Cormos, Delia; Leveque, Philippe; O'Connor, Rodney P

    2017-10-01

    Nanosecond pulsed electric fields (nsPEFs) have a variety of applications in the biomedical and biotechnology industries. Cancer treatment has been at the forefront of investigations thus far as nsPEFs permeabilize cellular and intracellular membranes leading to apoptosis and necrosis. nsPEFs may also influence ion channel gating and have the potential to modulate cell physiology without poration of the membrane. This phenomenon was explored using live cell imaging and a sensitive fluorescent probe of transmembrane voltage in the human glioblastoma cell line, U87 MG, known to express a number of voltage-gated ion channels. The specific ion channels involved in the nsPEF response were screened using a membrane potential imaging approach and a combination of pharmacological antagonists and ion substitutions. It was found that a single 10ns pulsed electric field of 34kV/cm depolarizes the transmembrane potential of cells by acting on specific voltage-sensitive ion channels; namely the voltage and Ca2 + gated BK potassium channel, L- and T-type calcium channels, and the TRPM8 transient receptor potential channel. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Elimination of bus voltage impact on temperature sensitive electrical parameter during turn-on transition for junction temperature estimation of high-power IGBT modules

    DEFF Research Database (Denmark)

    Luo, Haoze; Iannuzzo, Francesco; Blaabjerg, Frede

    2017-01-01

    Junction temperature is of great importance to safe operating area of IGBT modules. Various information of the IGBT operating state is reflected on electrical characteristics during turn-on transient. A unified extraction method for internal junction temperature via dynamic thermo......-sensitive electrical parameters (DTSEP) during turn-on transient is proposed. Two DTSEP, turn-on delay time (tdon) and the maximum increasing rate of collector current dic/dt(max), are combined to eliminate the bus voltage impact. Using the inherent emitter-auxiliary inductor LeE in high-power modules, the temperature......-dependent DTSEPs can be converted into a low-voltage and measurable signal. Finally, experiment results are exhibited to verify the effectiveness of proposed method....

  12. Performance analysis of the PLC (Power Line Communication) in medium voltage electrical networks; Analise de desempenho de sistemas PLC em redes eletricas de media tensao

    Energy Technology Data Exchange (ETDEWEB)

    Mota, A.A.; Paleta, R. [Pontificia Universidade Catolica de Campinas (PUC-Campinas), SP (Brazil)], E-mail: amota@puc-campinas.edu.br; Mota, L.T.M.; Ricardo, R.A. [Indelmatec Engenharia, Campinas, SP (Brazil)], E-mail: mota@indelmatec.com.br

    2009-07-01

    Nowadays, the information access in communication networks is widely explored due to the increase of Internet users. In this context, the PLC (Power Line Communication) technology is an alternative for data transmission. This technology is based on the usage of transmission/distribution power lines for data transmission. However there are some problems related to the usage of this technology: adequate data transmission rates and generation of acceptable levels of electromagnetic interference (EMI). This work had the objective of studying the performance of PLC systems in medium voltage electrical networks, through the assess of data transmission rates and the generated EMI. Tests were carried out in a test field that corresponded to a medium voltage electrical network and the obtained results show that, under some circumstances, the PLC system does not reach the existent technical recommendations. (author)

  13. Technical evaluation report on the adequacy of station electric distribution system voltages for the Point Beach Nuclear Plant, Units 1 and 2. (Docket Nos. 50-266, 50-301)

    International Nuclear Information System (INIS)

    White, R.L.

    1983-01-01

    This report documents the technical evaluation of the adequacy of the station electric distribution system voltages for the Point Beach Nuclear Plant, Units 1 and 2. The evaluation is to determine if the onsite distribution system, in conjunction with the offsite power sources, has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. For the worst case conditions study submitted by the licensee, it was shown that the station electric distribution system voltages would be adequate to start and operate 4160-volt and 480-volt Class 1E loads and their associated low voltage controls

  14. Smart regulation of rural electricity grids. Modern communications technology reduces the voltage fluctuations and regulates the storage of surplus electricity; Laendliches Stromnetz smart geregelt. Moderne Kommunikationstechnik reduziert Spannungsschwankungen und regelt die Speicherung ueberschuessigen Stroms

    Energy Technology Data Exchange (ETDEWEB)

    Durst, Anna

    2012-07-01

    In the ''Smart Country'' model project, researchers in Bitburg- Pruem were testing out the distribution network of the future. It is designed to respond flexibly to the increasingly decentralised generation of renewable electricity in the grid. For this purpose various operating resources were further developed: an optimised biogas plant, which controls the electricity supplied by the grid, virtually stores surplus electricity with an efficiency of 98 %. In addition, voltage regulators double the usable output capacity in the grid. The Eifel project successfully passed the field test after around one year. (orig.)

  15. New High Voltage Interconnections with Islands in the Mediterranean Sea: Malta and Sicily. Analysis of the Effects on Renewable Energy Sources Integration and Benefits for the Electricity Market

    Directory of Open Access Journals (Sweden)

    Mariano Giuseppe Ippolito

    2018-04-01

    Full Text Available The present paper shows the benefits coming from the operation of the recent electrical high voltage (HV interconnections between Sicily, Malta and mainland Italy. These new interconnections allow zonal prices of electricity considerably lower than in the past, ensuring greater flexibility to the system and a better integration of Renewable Energy Sources (RES. After briefly illustrating the two high-voltage electrical systems (Sicily and Malta, and having provided a description of the interconnection cable with Malta and its protection devices, the authors hypothesized two modes of operation (Sicily-Malta system islanded or interconnected to the rest of Europe. For the first case (islanded some simulations are performed through the use of an electric network model realized in the Neplan® environment, and for the second case an analysis of one year real data was made. The results of the simulation, thanks to the use of a power flow tracing method, show that this new interconnection between the two islands (Sicily and Malta allows an important improvement in the integration and dispatching of the power generated by RES of the Sicilian territory, better operation of traditional Sicilian generation units, lower electricity zonal prices and a significant reduction in emissions from obsolete fuel oil thermal units located in Malta.

  16. Device for monitoring cell voltage

    Science.gov (United States)

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  17. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  18. Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects.

    Science.gov (United States)

    VanGordon, James A; Kovaleski, Scott D; Norgard, Peter; Gall, Brady B; Dale, Gregory E

    2014-02-01

    The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model

  19. Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects

    Energy Technology Data Exchange (ETDEWEB)

    VanGordon, James A.; Kovaleski, Scott D., E-mail: kovaleskis@missouri.edu; Norgard, Peter; Gall, Brady B. [Department of Electrical and Computer Engineering, University of Missouri, Columbia, Missouri 65211 (United States); Dale, Gregory E. [High Power Electrodynamics Group, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2014-02-15

    The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model

  20. Development of a Novel Bidirectional DC/DC Converter Topology with High Voltage Conversion Ratio for Electric Vehicles and DC-Microgrids

    Directory of Open Access Journals (Sweden)

    Ching-Ming Lai

    2016-05-01

    Full Text Available The main objective of this paper was to study a bidirectional direct current to direct current converter (BDC topology with a high voltage conversion ratio for electric vehicle (EV batteries connected to a dc-microgrid system. In this study, an unregulated level converter (ULC cascaded with a two-phase interleaved buck-boost charge-pump converter (IBCPC is introduced to achieve a high conversion ratio with a simpler control circuit. In discharge state, the topology acts as a two-stage voltage-doubler boost converter to achieve high step-up conversion ratio (48 V to 385 V. In charge state, the converter acts as two cascaded voltage-divider buck converters to achieve high voltage step-down conversion ratio (385 V to 48 V. The features, operation principles, steady-state analysis, simulation and experimental results are made to verify the performance of the studied novel BDC. Finally, a 500 W rating prototype system is constructed for verifying the validity of the operation principle. Experimental results show that highest efficiencies of 96% and 95% can be achieved, respectively, in charge and discharge states.

  1. Integrated electrokinetics-adsorption remediation of saline-sodic soils: effects of voltage gradient and contaminant concentration on soil electrical conductivity.

    Science.gov (United States)

    Essa, Mohammed Hussain; Mu'azu, Nuhu Dalhat; Lukman, Salihu; Bukhari, Alaadin

    2013-01-01

    In this study, an integrated in situ remediation technique which couples electrokinetics with adsorption, using locally produced granular activated carbon from date palm pits in the treatment zones that are installed directly to bracket the contaminated soils at bench-scale, is investigated. Natural saline-sodic clay soil, spiked with contaminant mixture (kerosene, phenol, Cr, Cd, Cu, Zn, Pb, and Hg), was used in this study to investigate the effects of voltage gradient, initial contaminant concentration, and polarity reversal rate on the soil electrical conductivity. Box-Behnken Design (BBD) was used for the experimental design and response surface methodology (RSM) was employed to model, optimize, and interpret the results obtained using Design-Expert version 8 platform. The total number of experiments conducted was 15 with voltage gradient, polarity reversal rate, and initial contaminant concentration as variables. The main target response discussed in this paper is the soil electrical conductivity due to its importance in electrokinetic remediation process. Responses obtained were fitted to quadratic models whose R (2) ranges from 84.66% to 99.19% with insignificant lack of fit in each case. Among the investigated factors, voltage gradient and initial contaminant concentration were found to be the most significant influential factors.

  2. Integrated Electrokinetics-Adsorption Remediation of Saline-Sodic Soils: Effects of Voltage Gradient and Contaminant Concentration on Soil Electrical Conductivity

    Directory of Open Access Journals (Sweden)

    Mohammed Hussain Essa

    2013-01-01

    Full Text Available In this study, an integrated in situ remediation technique which couples electrokinetics with adsorption, using locally produced granular activated carbon from date palm pits in the treatment zones that are installed directly to bracket the contaminated soils at bench-scale, is investigated. Natural saline-sodic clay soil, spiked with contaminant mixture (kerosene, phenol, Cr, Cd, Cu, Zn, Pb, and Hg, was used in this study to investigate the effects of voltage gradient, initial contaminant concentration, and polarity reversal rate on the soil electrical conductivity. Box-Behnken Design (BBD was used for the experimental design and response surface methodology (RSM was employed to model, optimize, and interpret the results obtained using Design-Expert version 8 platform. The total number of experiments conducted was 15 with voltage gradient, polarity reversal rate, and initial contaminant concentration as variables. The main target response discussed in this paper is the soil electrical conductivity due to its importance in electrokinetic remediation process. Responses obtained were fitted to quadratic models whose R2 ranges from 84.66% to 99.19% with insignificant lack of fit in each case. Among the investigated factors, voltage gradient and initial contaminant concentration were found to be the most significant influential factors.

  3. Electrically controlled fuel injection system for an internal combustion engine with a control multi-vibrator and electrical correction of the voltage. Elektrisch gesteuerte Kraftstoffeinspritzanlage fuer eine Brennkraftmaschine mit einem Steuermultivibrator und elektrischer Spannungskorrektur

    Energy Technology Data Exchange (ETDEWEB)

    Busse, W; Drews, U; Moeder, H; Ohr, K; Werner, P

    1980-06-19

    The invention concerns an electrically controlled fuel injection system for an internal combustion engine with at least one solenoid operated injection valve and a power transistor in series with the magnetising winding of the valve and with a control multi-vibrator connected before this, which is switched on synchronously with the crankshaft rotation with simultaneous opening of the injection valve, and which is kept in this state for a period determining the quantity injected, depending on the quantity of suction air. A control pulse is supplied for at least one injection valve, which is extended by a voltage correction stage proportionally to the voltage of a source of electrical supply provided for operating the injection valve, particularly to a vehicle battery. It has been found that the delay in response of the solenoid injection valves is independent of the duration of the opening pulse and must be compensated by an additional fuse independent of the length of the opening pulse, whose duration increases with increasing voltage drop. According to the invention this is achieved by a voltage-correcting stage with a Zener diode and several transistors. The individual operating steps are made clear by 3 patent claims and several detailed circuit diagrams and pulse-time graphs.

  4. Various mechanisms and clinical phenotypes in electrical short circuits of high-voltage devices: report of four cases and review of the literature.

    Science.gov (United States)

    Tsurugi, Takuo; Matsui, Shogo; Nakajima, Hiroshi; Nishii, Nobuhiro; Honda, Toshihiro; Kaneko, Yoshiaki

    2015-06-01

    An electrical short circuit is a rare complication in a high-voltage implantable cardioverter-defibrillator (ICD). However, the inability of an ICD to deliver appropriate shock therapy can be life-threatening. During the last 2 years, four cases of serious complications related to an electrical short circuit have been reported in Japan. A spark due to an electrical short circuit resulted in the failure of an ICD shock to terminate ventricular tachycardia and total damage to the ICD generator in three of four cases. Two of the four patients died from an electrical short circuit between the right ventricle and superior vena cava (SVC) leads. The others had audible sounds from the ICD generator site and were diagnosed with a lead-to-can abrasion, which was manifested by the arc mark on the surface of the can. It is still difficult to predict the occurrence of an electrical short circuit in current ICD systems. To reduce the probability of an electrical short circuit, we suggest the following: (i) avoid lead stress at ICD implantation, (ii) select a single-coil lead instead of a dual-coil lead, or (iii) use a unique algorithm which automatically disconnect can or SVC lead from shock deliver circuit when excessive current was detected. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  5. Efficient design and simulation of an expandable hybrid (wind-photovoltaic) power system with MPPT and inverter input voltage regulation features in compliance with electric grid requirements

    Energy Technology Data Exchange (ETDEWEB)

    Skretas, Sotirios B.; Papadopoulos, Demetrios P. [Electrical Machines Laboratory, Department of Electrical and Computer Engineering, Democritos University of Thrace (DUTH), 12 V. Sofias, 67100 Xanthi (Greece)

    2009-09-15

    In this paper an efficient design along with modeling and simulation of a transformer-less small-scale centralized DC - bus Grid Connected Hybrid (Wind-PV) power system for supplying electric power to a single phase of a three phase low voltage (LV) strong distribution grid are proposed and presented. The main components of the hybrid system are: a PV generator (PVG); and an array of horizontal-axis, fixed-pitch, small-size, variable-speed wind turbines (WTs) with direct-driven permanent magnet synchronous generator (PMSG) having an embedded uncontrolled bridge rectifier. An overview of the basic theory of such systems along with their modeling and simulation via Simulink/MATLAB software package are presented. An intelligent control method is applied to the proposed configuration to simultaneously achieve three desired goals: to extract maximum power from each hybrid power system component (PVG and WTs); to guarantee DC voltage regulation/stabilization at the input of the inverter; to transfer the total produced electric power to the electric grid, while fulfilling all necessary interconnection requirements. Finally, a practical case study is conducted for the purpose of fully evaluating a possible installation in a city site of Xanthi/Greece, and the practical results of the simulations are presented. (author)

  6. Utilization of low- and high-voltage electric equipment at heights exceeding 1000 m above sea level

    Energy Technology Data Exchange (ETDEWEB)

    Karapetyan, M.M.

    1980-01-01

    The present-day state of high- and low-voltage equipment utilization at heights exceeding 1000 m above sea level is considered with allowance for the technical requirements applicable to the equipment, as provided for in the GOST (All-Union State Standards), and for the results of scientific research studies. 12 refs.

  7. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  8. Analysis of the Mechanisms Determining the Thermal and Electrical Properties of Epoxy Nanocomposites for High Voltage Applications

    NARCIS (Netherlands)

    Tsekmes, I.A.

    2016-01-01

    The addition of microsized fillers to polymers, in order to tailor their properties, has been extensively used in many industrial applications since the 1960s. The same approach applies to the field of electrical insulation. Epoxy resin is a widely used polymer in the electrical power sector, but it

  9. Electric long-term behaviour of polyethylene insulations for medium-voltage cables cross-linked chemically or by radiation

    International Nuclear Information System (INIS)

    Scharff, C.; Eberhardt, M.

    1989-01-01

    The electric long-term behaviour of cross-linked polyethylene (CLPE) was studied at room temperature by measuring the channel operating time under needling and the total charge before channel operation. It is found that the decomposition products formed in CLPE act as tension stabilizers. They have a dominating influence on the electric long-term behaviour

  10. The influence of anatomical and physiological parameters on the interference voltage at the input of unipolar cardiac pacemakers in low frequency electric fields

    Energy Technology Data Exchange (ETDEWEB)

    Joosten, S; Pammler, K; Silny, J [Research Center for Bioelectromagnetic Interaction (FEMU), University Hospital, Aachen University (Germany)], E-mail: joosten@femu.rwth-aachen.de

    2009-02-07

    The problem of electromagnetic interference of electronic implants such as cardiac pacemakers has been well known for many years. An increasing number of field sources in everyday life and occupational environment leads unavoidably to an increased risk for patients with electronic implants. However, no obligatory national or international safety regulations exist for the protection of this patient group. The aim of this study is to find out the anatomical and physiological worst-case conditions for patients with an implanted pacemaker adjusted to unipolar sensing in external time-varying electric fields. The results of this study with 15 volunteers show that, in electric fields, variation of the interference voltage at the input of a cardiac pacemaker adds up to 200% only because of individual factors. These factors should be considered in human studies and in the setting of safety regulations.

  11. The influence of anatomical and physiological parameters on the interference voltage at the input of unipolar cardiac pacemakers in low frequency electric fields

    International Nuclear Information System (INIS)

    Joosten, S; Pammler, K; Silny, J

    2009-01-01

    The problem of electromagnetic interference of electronic implants such as cardiac pacemakers has been well known for many years. An increasing number of field sources in everyday life and occupational environment leads unavoidably to an increased risk for patients with electronic implants. However, no obligatory national or international safety regulations exist for the protection of this patient group. The aim of this study is to find out the anatomical and physiological worst-case conditions for patients with an implanted pacemaker adjusted to unipolar sensing in external time-varying electric fields. The results of this study with 15 volunteers show that, in electric fields, variation of the interference voltage at the input of a cardiac pacemaker adds up to 200% only because of individual factors. These factors should be considered in human studies and in the setting of safety regulations.

  12. Capacitance-voltage analysis of electrical properties for WSe2 field effect transistors with high-k encapsulation layer

    Science.gov (United States)

    Ko, Seung-Pil; Shin, Jong Mok; Jang, Ho Kyun; You, Min Youl; Jin, Jun-Eon; Choi, Miri; Cho, Jiung; Kim, Gyu-Tae

    2018-02-01

    Doping effects in devices based on two-dimensional (2D) materials have been widely studied. However, detailed analysis and the mechanism of the doping effect caused by encapsulation layers has not been sufficiently explored. In this work, we present experimental studies on the n-doping effect in WSe2 field effect transistors (FETs) with a high-k encapsulation layer (Al2O3) grown by atomic layer deposition. In addition, we demonstrate the mechanism and origin of the doping effect. After encapsulation of the Al2O3 layer, the threshold voltage of the WSe2 FET negatively shifted with the increase of the on-current. The capacitance-voltage measurements of the metal insulator semiconductor (MIS) structure proved the presence of the positive fixed charges within the Al2O3 layer. The flat-band voltage of the MIS structure of Au/Al2O3/SiO2/Si was shifted toward the negative direction on account of the positive fixed charges in the Al2O3 layer. Our results clearly revealed that the fixed charges in the Al2O3 encapsulation layer modulated the Fermi energy level via the field effect. Moreover, these results possibly provide fundamental ideas and guidelines to design 2D materials FETs with high-performance and reliability.

  13. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013)

    Science.gov (United States)

    Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677

  14. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013

    Directory of Open Access Journals (Sweden)

    Pedro M. Lara-Santillán

    2014-01-01

    Full Text Available This paper presents a comparative study of the electricity consumption (EC in an urban low-voltage substation before and during the economic crisis (2008–2013. This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012 with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis. These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.. The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.

  15. Accurate measurement of junctional conductance between electrically coupled cells with dual whole-cell voltage-clamp under conditions of high series resistance.

    Science.gov (United States)

    Hartveit, Espen; Veruki, Margaret Lin

    2010-03-15

    Accurate measurement of the junctional conductance (G(j)) between electrically coupled cells can provide important information about the functional properties of coupling. With the development of tight-seal, whole-cell recording, it became possible to use dual, single-electrode voltage-clamp recording from pairs of small cells to measure G(j). Experiments that require reduced perturbation of the intracellular environment can be performed with high-resistance pipettes or the perforated-patch technique, but an accompanying increase in series resistance (R(s)) compromises voltage-clamp control and reduces the accuracy of G(j) measurements. Here, we present a detailed analysis of methodologies available for accurate determination of steady-state G(j) and related parameters under conditions of high R(s), using continuous or discontinuous single-electrode voltage-clamp (CSEVC or DSEVC) amplifiers to quantify the parameters of different equivalent electrical circuit model cells. Both types of amplifiers can provide accurate measurements of G(j), with errors less than 5% for a wide range of R(s) and G(j) values. However, CSEVC amplifiers need to be combined with R(s)-compensation or mathematical correction for the effects of nonzero R(s) and finite membrane resistance (R(m)). R(s)-compensation is difficult for higher values of R(s) and leads to instability that can damage the recorded cells. Mathematical correction for R(s) and R(m) yields highly accurate results, but depends on accurate estimates of R(s) throughout an experiment. DSEVC amplifiers display very accurate measurements over a larger range of R(s) values than CSEVC amplifiers and have the advantage that knowledge of R(s) is unnecessary, suggesting that they are preferable for long-duration experiments and/or recordings with high R(s). Copyright (c) 2009 Elsevier B.V. All rights reserved.

  16. Online model-based estimation of state-of-charge and open-circuit voltage of lithium-ion batteries in electric vehicles

    International Nuclear Information System (INIS)

    He, Hongwen; Zhang, Xiaowei; Xiong, Rui; Xu, Yongli; Guo, Hongqiang

    2012-01-01

    This paper presents a method to estimate the state-of-charge (SOC) of a lithium-ion battery, based on an online identification of its open-circuit voltage (OCV), according to the battery’s intrinsic relationship between the SOC and the OCV for application in electric vehicles. Firstly an equivalent circuit model with n RC networks is employed modeling the polarization characteristic and the dynamic behavior of the lithium-ion battery, the corresponding equations are built to describe its electric behavior and a recursive function is deduced for the online identification of the OCV, which is implemented by a recursive least squares (RLS) algorithm with an optimal forgetting factor. The models with different RC networks are evaluated based on the terminal voltage comparisons between the model-based simulation and the experiment. Then the OCV-SOC lookup table is built based on the experimental data performed by a linear interpolation of the battery voltages at the same SOC during two consecutive discharge and charge cycles. Finally a verifying experiment is carried out based on nine Urban Dynamometer Driving Schedules. It indicates that the proposed method can ensure an acceptable accuracy of SOC estimation for online application with a maximum error being less than 5.0%. -- Highlights: ► An equivalent circuit model with n RC networks is built for lithium-ion batteries. ► A recursive function is deduced for the online estimation of the model parameters like OCV and R O . ► The relationship between SOC and OCV is built with a linear interpolation method by experiments. ► The experiments show the online model-based SOC estimation is reasonable with enough accuracy.

  17. Stunning effect of different rifle-bullets for slaughter of outdoor cattle

    Directory of Open Access Journals (Sweden)

    Stefanie Retz

    2014-12-01

    Full Text Available The slaughter method via gunshot implies a stunning of cattle by means of a targeted shot from a rifle and is as an alternative to regular slaughter at abattoirs. This method is only permitted under restricted circumstances and if the cattle is held on a pasture all the year. However, there is a considerable lack of specifications regulated by law concerning calibre and bullet-type. In this study, four different calibres, two bullet-types and two different shot placements were investigated with respect to their stunning efficiency. All of the calibres exhibited an entry-energy over 400 J and provided sufficient stunning potential. Yet, only calibre .22 Magnum caused no exit of the bullet out of the scull, which provides higher safety conditions for man and cattle.

  18. Analysis of current-voltage characteristics of Au/pentacene/fluorine polymer/indium zinc oxide diodes by electric-field-induced optical second-harmonic generation

    Energy Technology Data Exchange (ETDEWEB)

    Nishi, Shohei; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa, E-mail: iwamoto@pe.titech.ac.jp [Department of Physical Electronics, Tokyo Institute of Technology, 2-12-1 S3-33, O-okayama, Meguro-ku, Tokyo 152-8552 (Japan)

    2015-06-28

    By using electric-field-induced optical second-harmonic generation measurement coupled with the conventional current-voltage (I-V) measurement, we studied the carrier transport of organic double-layer diodes with a Au/pentacene/fluorine polymer (FP)/indium zinc oxide (IZO) structure. The rectifying I-V characteristics were converted into the I-E characteristics of the FP and pentacene layers. Results suggest a model in which Schottky-type electron injection from the IZO electrode to the FP layer governs the forward electrical conduction (V > 0), where the space charge electric field produced in the FP layer by accumulated holes at the pentacene/FP interface makes a significant contribution. On the other hand, Schottky-type injection by accumulated interface electrons from the pentacene layer to the FP layer governs the backward electrical conduction (V < 0). The electroluminescence generated from the pentacene layer in the region V > 0 verifies the electron transport across the FP layer, and supports the above suggested model.

  19. Analysis of current-voltage characteristics of Au/pentacene/fluorine polymer/indium zinc oxide diodes by electric-field-induced optical second-harmonic generation

    International Nuclear Information System (INIS)

    Nishi, Shohei; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa

    2015-01-01

    By using electric-field-induced optical second-harmonic generation measurement coupled with the conventional current-voltage (I-V) measurement, we studied the carrier transport of organic double-layer diodes with a Au/pentacene/fluorine polymer (FP)/indium zinc oxide (IZO) structure. The rectifying I-V characteristics were converted into the I-E characteristics of the FP and pentacene layers. Results suggest a model in which Schottky-type electron injection from the IZO electrode to the FP layer governs the forward electrical conduction (V > 0), where the space charge electric field produced in the FP layer by accumulated holes at the pentacene/FP interface makes a significant contribution. On the other hand, Schottky-type injection by accumulated interface electrons from the pentacene layer to the FP layer governs the backward electrical conduction (V < 0). The electroluminescence generated from the pentacene layer in the region V > 0 verifies the electron transport across the FP layer, and supports the above suggested model

  20. Controlled Operation of the Islanded Portion of the International Council on Large Electric Systems (CIGRE) Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak, Claus Leth; Ali, Ehsan

    2017-01-01

    In islanding, a portion of the power network, comprised of the loads and distributed generation (DG) units, is isolated from the rest of the power grid and forms a micro grid (MG). In this condition, it becomes essential for the islanded MG to operate in a stable and controlled manner by providing...... ancillary services. When the MG is cut off from the main grid, the islanding must be detected by the DG units. In this condition it is essential that one of the controllers should be switched to the voltage-frequency (VF) control mode. In islanding, the network loses it slack reference and this reference...

  1. Bleeding Efficiency and Meat Oxidative Stability and Microbiological Quality of New Zealand White Rabbits Subjected to Halal Slaughter without Stunning and Gas Stun-killing

    Science.gov (United States)

    Nakyinsige, K.; Fatimah, A. B.; Aghwan, Z. A.; Zulkifli, I.; Goh, Y. M.; Sazili, A. Q.

    2014-01-01

    A study was conducted to compare the effect of halal slaughter without stunning and gas stun killing followed by bleeding on residual blood content and storage stability of rabbit meat. Eighty male New Zealand white rabbits were divided into two groups of 40 animals each and subjected to either halal slaughter without stunning (HS) or gas stun-kill (GK). The volume of blood lost during exsanguination was measured. Residual blood was further quantified by determination of haemoglobin content in Longissimus lumborum (LL) muscle. Storage stability of the meat was evaluated by microbiological analysis and measuring lipid oxidation in terms of thiobarbituric acid reactive substances (TBARS). HS resulted in significantly higher blood loss than GK. HS had significantly lower residual haemoglobin in LL muscle compared to GK. Slaughter method had no effect on rabbit meat lipid oxidation at 0, 1, and 3 d postmortem. However, at 5 and 8 days of storage at 4°C, significant differences (p<0.05) were found, with meat from the GK group exhibiting significantly higher levels of MDA than that from HS. At day 3, greater growth of Pseudomonas aeroginosa and E. coli were observed in the GK group (p<0.05) with B. thermosphacta and total aerobic counts remained unaffected by slaughter method. At days 5 and 7 postmortem, bacterial counts for all tested microbes were affected by slaughter method, with GK exhibiting significantly higher growth than HS. It can be concluded that slaughter method can affect keeping quality of rabbit meat, and HS may be a favourable option compared to GK due to high bleed out. PMID:25049968

  2. Bleeding Efficiency and Meat Oxidative Stability and Microbiological Quality of New Zealand White Rabbits Subjected to Halal Slaughter without Stunning and Gas Stun-killing

    Directory of Open Access Journals (Sweden)

    K. Nakyinsige

    2014-03-01

    Full Text Available A study was conducted to compare the effect of halal slaughter without stunning and gas stun killing followed by bleeding on residual blood content and storage stability of rabbit meat. Eighty male New Zealand white rabbits were divided into two groups of 40 animals each and subjected to either halal slaughter without stunning (HS or gas stun-kill (GK. The volume of blood lost during exsanguination was measured. Residual blood was further quantified by determination of haemoglobin content in Longissimus lumborum (LL muscle. Storage stability of the meat was evaluated by microbiological analysis and measuring lipid oxidation in terms of thiobarbituric acid reactive substances (TBARS. HS resulted in significantly higher blood loss than GK. HS had significantly lower residual haemoglobin in LL muscle compared to GK. Slaughter method had no effect on rabbit meat lipid oxidation at 0, 1, and 3 d postmortem. However, at 5 and 8 days of storage at 4°C, significant differences (p<0.05 were found, with meat from the GK group exhibiting significantly higher levels of MDA than that from HS. At day 3, greater growth of Pseudomonas aeroginosa and E. coli were observed in the GK group (p<0.05 with B. thermosphacta and total aerobic counts remained unaffected by slaughter method. At days 5 and 7 postmortem, bacterial counts for all tested microbes were affected by slaughter method, with GK exhibiting significantly higher growth than HS. It can be concluded that slaughter method can affect keeping quality of rabbit meat, and HS may be a favourable option compared to GK due to high bleed out.

  3. Bleeding Efficiency and Meat Oxidative Stability and Microbiological Quality of New Zealand White Rabbits Subjected to Halal Slaughter without Stunning and Gas Stun-killing.

    Science.gov (United States)

    Nakyinsige, K; Fatimah, A B; Aghwan, Z A; Zulkifli, I; Goh, Y M; Sazili, A Q

    2014-03-01

    A study was conducted to compare the effect of halal slaughter without stunning and gas stun killing followed by bleeding on residual blood content and storage stability of rabbit meat. Eighty male New Zealand white rabbits were divided into two groups of 40 animals each and subjected to either halal slaughter without stunning (HS) or gas stun-kill (GK). The volume of blood lost during exsanguination was measured. Residual blood was further quantified by determination of haemoglobin content in Longissimus lumborum (LL) muscle. Storage stability of the meat was evaluated by microbiological analysis and measuring lipid oxidation in terms of thiobarbituric acid reactive substances (TBARS). HS resulted in significantly higher blood loss than GK. HS had significantly lower residual haemoglobin in LL muscle compared to GK. Slaughter method had no effect on rabbit meat lipid oxidation at 0, 1, and 3 d postmortem. However, at 5 and 8 days of storage at 4°C, significant differences (p<0.05) were found, with meat from the GK group exhibiting significantly higher levels of MDA than that from HS. At day 3, greater growth of Pseudomonas aeroginosa and E. coli were observed in the GK group (p<0.05) with B. thermosphacta and total aerobic counts remained unaffected by slaughter method. At days 5 and 7 postmortem, bacterial counts for all tested microbes were affected by slaughter method, with GK exhibiting significantly higher growth than HS. It can be concluded that slaughter method can affect keeping quality of rabbit meat, and HS may be a favourable option compared to GK due to high bleed out.

  4. Conducted EMI Prediction and Mitigation Strategy Based on Transfer Function for a High-Low Voltage DC-DC Converter in Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Li Zhai

    2018-04-01

    Full Text Available The high dv/dt and di/dt outputs from power devices in a high-low voltage DC-DC converter on electric vehicles (EVs can always introduce the unwanted conducted electromagnetic interference (EMI emissions. A conducted EMI prediction and mitigation strategy that is based on transfer function for the high-low voltage DC-DC converter in EVs are proposed. A complete test for the DC-DC converter is conducted to obtain the conducted EMI from DC power cables in the frequency band of 150 kHz-108 MHz. The equivalent circuit with high-frequency parasitic parameters of the DC-DC converter is built`1 based on the measurement results to acquire the characteristics of the conducted EMI of the DC power cables. The common mode (CM and differential mode (DM propagation coupling paths are determined, and the corresponding transfer functions of the DM interference and CM interference are established. The simulation results of the conducted EMI can be obtained by software Matlab and Computer Simulation Technology (CST. By analyzing the transfer functions and the simulation results, the dominated interference is the CM interference, which is the main factor of the conducted EMI. A mitigation strategy for the design of the CM interference filter based on the dominated CM interference is proposed. Finally, the mitigation strategy of the conducted EMI is verified by performing the conducted voltage experiment. From the experiment results, the conducted voltage of the DC power cables is decreased, respectively, by 58 dBμV, 55 dBμV, 65 dBμV, 53 dBμV, and 54 dBμV at frequency 200 kHz, 400 kHz, 600 kHz, 1.4 MHz, and 50 MHz. The conduced voltage in the frequency band of 150 kHz–108 MHz can be mitigated by adding the CM interference filters, and the values are lower than the limit level-3 of CISPR25 standard (GB/T 18655-2010.

  5. Evaluation of the effectiveness of neurofeedback in the reduction of Posttraumatic stress disorder (PTSD in a patient following high-voltage electric shock with the use of ERPs

    Directory of Open Access Journals (Sweden)

    Anna Chrapusta

    2015-09-01

    Full Text Available Background. The aim of our research was an evaluation of the effectiveness of neurofeedback in reducing the symptoms of Post-trauma stress disorder (PTSD, which had developed as a result of a high-voltage electric burn to the head. Quantitative EEG (QEEG and Event related potentials (ERPs were utilised in the evaluation. Case study. A 21-year-old patient, experienced 4[sup]th[/sup] degree burns to his head as a result of a high-voltage electric burn. The patient was repeatedly operated on and despite the severity of the injuries was to recover. However the patient complained of flashbacks, difficulties with sleeping as well as an inability to continue work in his given profession. Specialist tests were to show the presence within him of PTSD. As a result of which the patient was provided with neurofeedback therapy. The effectiveness of this therapy in the reduction (eradication of the symptoms of PTSD were evaluated through the utilisation of qantitative eeg (Qeeg and event related potentials (ERPs. Results. It was found that in the first examination that ERPs display the most significant deviations from the reference in the two components: (1 the one component is generated within the cingulate cortex. The pattern of its deviation from the norms is similar to that found in a group of OCD patients. In contrast to healthy subjects the component repeats itself twice; (2 the second component is generated in the medial prefrontal cortex. Its pattern (neuromarker is similar to that found in PTSD patients. There is a delay in the late part of the component, which probably reflects the flashbacks. In the second examination, after neurofeedback training, the ERPs were similar to the norm. The patient returned to work. Conclusions. Chronic PTSD developed within the patient as a result of a high-voltage electric burn. The application of a method of therapy (neurofeedback resulted in the withdrawal of the syndrome symptoms. ERPs in a GO/NOGO task can be

  6. Evaluation of the effectiveness of neurofeedback in the reduction of Posttraumatic stress disorder (PTSD) in a patient following high-voltage electric shock with the use of ERPs.

    Science.gov (United States)

    Chrapusta, Anna; Pąchalska, Maria; Wilk-Frańczuk, Magdalena; Starczyńska, Małgorzata; Kropotov, Juri D

    2015-01-01

    The aim of our research was an evaluation of the effectiveness of neurofeedback in reducing the symptoms of Post-trauma stress disorder (PTSD), which had developed as a result of a high-voltage electric burn to the head. Quantitative EEG (QEEG) and Event related potentials (ERPs) were utilised in the evaluation. A 21-year-old patient, experienced 4(th) degree burns to his head as a result of a high-voltage electric burn. The patient was repeatedly operated on and despite the severity of the injuries was to recover. However the patient complained of flashbacks, difficulties with sleeping as well as an inability to continue work in his given profession. Specialist tests were to show the presence within him of PTSD. As a result of which the patient was provided with neurofeedback therapy. The effectiveness of this therapy in the reduction (eradication) of the symptoms of PTSD were evaluated through the utilisation of qantitative eeg (Qeeg) and event related potentials (ERPs). It was found that in the first examination that ERPs display the most significant deviations from the reference in the two components: (1) the one component is generated within the cingulate cortex. The pattern of its deviation from the norms is similar to that found in a group of OCD patients. In contrast to healthy subjects the component repeats itself twice; (2) the second component is generated in the medial prefrontal cortex. Its pattern (neuromarker) is similar to that found in PTSD patients. There is a delay in the late part of the component, which probably reflects the flashbacks. In the second examination, after neurofeedback training, the ERPs were similar to the norm. The patient returned to work. Chronic PTSD developed within the patient as a result of a high-voltage electric burn. The application of a method of therapy (neurofeedback) resulted in the withdrawal of the syndrome symptoms. ERPs in a GO/NOGO task can be used to plan neurofeedback and in the assessment of functional brain

  7. Phase Balancing by Means of Electric Vehicles Single-Phase Connection Shifting in a Low Voltage Danish Grid

    DEFF Research Database (Denmark)

    Lico, Pasqualino; Marinelli, Mattia; Knezovic, Katarina

    2015-01-01

    In Denmark, household consumers are supplied with three phase with neutral cable. In addition, the distribution service operator cannot decide to which phase electrical appliance are connected. The technician who realizes the installation connects the loads according to his technical expertise...

  8. Numerical Simulation of Voltage Electric Field in Complex Geometries for Different Electrode Arrangements using Meshless Local MQ-DQ Method

    DEFF Research Database (Denmark)

    Jalaal, M.; Soleimani, Soheil; Domairry, G.

    2011-01-01

    In this paper the meshless Local Multi Quadrics-based Differential Quadrature (MQ-DQ) method is applied to obtain the electric field distribution for different applicable irregular geometries. This method is the combination of Differential Quadrature approximation of derivatives and function...

  9. Breakdown voltage at the electric terminals of GCFR-core flow test loop fuel rod simulators in helium and air

    International Nuclear Information System (INIS)

    Huntley, W.R.; Conley, T.B.

    1979-12-01

    Tests were performed to determine the ac and dc breakdown voltage at the terminal ends of a fuel rod simulator (FRS) in helium and air atmospheres. The tests were performed at low pressures (1 to 2 atm) and at temperatures from 20 to 350 0 C (68 to 660 0 F). The area of concern was the 0.64-mm (0.025-in.) gap between the coaxial conductor of the FRS and the sheaths of the four internal thermocouples as they exit the FRS. The tests were prformed to ensure a sufficient safety margin during Core Flow Test Loop (CFTL) operations that require potentials up to 350 V ac at the FRS terminals. The primary conclusion from the test results is that the CFTL cannot be operated safely if the terminal ends of the FRSs are surrounded by a helium atmosphere but can be operated safely in air

  10. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  11. Technical evaluation report on the adequacy of station electric-distribution-system voltages for the Millstone Nuclear Power Station, Units 1 and 2. Docket Nos. 50-245, 50-336

    International Nuclear Information System (INIS)

    Selan, J.C.

    1983-01-01

    This report documents the technical evaluation of the adequacy of the station electric-distribution-system voltages for the Millstone Nuclear Power Station, Units 1 and 2. The evaluation is to determine if the onsite distribution system, in conjunction with the offsite power sources, has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. The analyses submitted demonstrate that adequate voltages will be supplied to the Class 1E equipment under the worst-case conditions analyzed

  12. A facile approach for reducing the working voltage of Au/TiO2/Au nanostructured memristors by enhancing the local electric field

    Science.gov (United States)

    Arab Bafrani, Hamidreza; Ebrahimi, Mahdi; Bagheri Shouraki, Saeed; Moshfegh, Alireza Z.

    2018-01-01

    Memristor devices have attracted tremendous interest due to different applications ranging from nonvolatile data storage to neuromorphic computing units. Exploring the role of surface roughness of the bottom electrode (BE)/active layer interface provides useful guidelines for the optimization of the memristor switching performance. This study focuses on the effect of surface roughness of the BE electrode on the switching characteristics of Au/TiO2/Au three-layer memristor devices. An optimized wet-etching treatment condition was found to modify the surface roughness of the Au BE where the measurement results indicate that the roughness of the Au BE is affected by both duration time and solution concentrations of the wet-etching process. Then we fabricated arrays of TiO2-based nanostructured memristors sandwiched between two sets of cross-bar Au electrode lines (junction area 900 μm2). The results revealed a reduction in the working voltages in current-voltage characteristic of the device performance when increasing the surface roughness at the Au(BE)/TiO2 active layer interface. The set voltage of the device (Vset) significantly decreased from 2.26-1.93 V when we increased the interface roughness from 4.2-13.1 nm. The present work provides information for better understanding the switching mechanism of titanium-dioxide-based devices, and it can be inferred that enhancing the roughness of the Au BE/TiO2 active layer interface leads to a localized non-uniform electric field distribution that plays a vital role in reducing the energy consumption of the device.

  13. THE EFFECT OF TWO STUNNING TECHNIQUES ON THE pH 1 ...

    African Journals Online (AJOL)

    Violent muscle con- tractions resulting from stunning by captive bolt pistol were responsible for the low pHI values at Abattoir B. The major cause of pale, soft and exudative (PSE) pork is the ... to varying conditions existing at the two abattoirs measure- ments were .... muscular contraction was avoided and that it was low.

  14. Effect of stunning methods on quality of rabbit carcass and meat ...

    African Journals Online (AJOL)

    Thereafter the were dissected into 2 halves and fabricated into primal cuts. Carcass characteristics as well as physical, chemical and sensory properties of the rabbit meat were determined. The results showed that carcasses of rabbits stunned with gas gave higher (P<0.05) blood loss and lower (P<0.05) chilling loss.

  15. Physiological responses to low atmospheric pressure stunning and the implications for welfare

    NARCIS (Netherlands)

    Mckeegan, D.E.F.; Sandercock, D.A.; Gerritzen, M.A.

    2013-01-01

    In low atmospheric pressure stunning (LAPS), poultry are rendered unconscious before slaughter by gradually reducing oxygen tension in the atmosphere to achieve a progressive anoxia. The effects of LAPS are not instantaneous, so there are legitimate welfare concerns around the experience of birds

  16. Neurogenic Stunned Myocardium Associated with Acute Spinal Cord Infarction: A Case Report

    Directory of Open Access Journals (Sweden)

    Gillian A. Beauchamp

    2012-01-01

    Full Text Available Introduction. Neurogenic stunned myocardium (NSM is a reversible cardiomyopathy resulting in transient left ventricular apical ballooning presumed to result from catecholamine surge occurring under physiologic stress. Acute spinal cord ischemia is a rare ischemic vascular lesion. We report a case of neurogenic stunned myocardium occurring in the setting of acute spinal cord infarction. Methods. Singe case report was used. Results. We present the case of a 63-year-old female with a history of prior lacunar stroke, hypertension, chronic back pain, and hypothyroidism who presented with a brief episode of diffuse abdominal and bilateral lower extremity pain which progressed within minutes to bilateral lower extremity flaccid paralysis. MRI of the spinal cord revealed central signal hyperintensity of T2-weighted imaging from conus to T8 region, concerning for acute spinal cord ischemia. Transthoracic echocardiogram was performed to determine if a cardiac embolic phenomenon may have precipitated this ischemic event and showed left ventricular apical hypokinesis and ballooning concerning for NSM. Conclusion. Neurogenic stunned myocardium is a reversible cardiomyopathy which has been described in patients with physiologic stress resulting in ventricular apical ballooning. Our case suggests that it is possible for neurogenic stunned myocardium to occur in the setting of acute spinal cord ischemia.

  17. Reduction in beta-myosin heavy chains in stunned myocardium as assessed by nondenaturing gel electrophoresis.

    Science.gov (United States)

    Garcia, S C; Pomblum, V J; Gams, E; Rupp, H; Schipke, J D

    2007-09-01

    Myosin plays a key role in the structure and function of cardiac muscle. Three myosin isoenzymes (V(1), V(2), and V(3)) with different ATPase activities have been identified in mammalian ventricles based on their heavy chain constituents. The relative amount of myosin isoenzymes changes under physiological and pathological conditions. Until now, myosin isoenzymes have frequently been determined using either tube gel (nondenaturing) polyacrylamide gel electrophoresis (PAGE), or gradient or uniform sodium dodecyl sulfate (denaturing) PAGE. Both methods have disadvantages, e.g., a long running time. We developed, therefore, a uniform, nondenaturing PAGE with slab minigel format for analyzing the myosin isoenzymes in normoxic and stunned rabbit hearts. In normoxic hearts of adult rabbits, V(3) predominated over V(1) (46 vs 41%). In turn, in the stunned hearts, V(1) predominated over V(3) (70 vs 30%), and the heterodimeric V(2) was not anymore detectable. This alteration appears to result from a selective loss of myosin heavy chain (MHC)-beta. In parallel, the biochemical markers troponin I and creatine kinase were increased in the stunned hearts. We suggest that alterations of myosin isoenzymes in stunned myocardium can be monitored with native PAGE. The present analysis of myosin isoenzyme appears thus as a new tool for evaluating defects in MHC dimer formation in postischemic hearts.

  18. Invariant protection of high-voltage electric motors of technological complexes at industrial enterprises at partial single-phase ground faults

    Science.gov (United States)

    Abramovich, B. N.; Sychev, Yu A.; Pelenev, D. N.

    2018-03-01

    Development results of invariant protection of high-voltage motors at incomplete single-phase ground faults are observed in the article. It is established that current protections have low action selectivity because of an inadmissible decrease in entrance signals during the shirt circuit occurrence in the place of transient resistance. The structural functional scheme and an algorithm of protective actions where correction of automatic zero sequence currents signals of the protected accessions implemented according to the level of incompleteness of ground faults are developed. It is revealed that automatic correction of zero sequence currents allows one to provide the invariance of sensitivity factor for protection under the variation conditions of a transient resistance in the place of damage. Application of invariant protection allows one to minimize damages in 6-10 kV electrical installations of industrial enterprises for a cause of infringement of consumers’ power supply and their system breakdown due to timely localization of emergency of ground faults modes.

  19. Inverted Fuel Cell: Room-Temperature Hydrogen Separation from an Exhaust Gas by Using a Commercial Short-Circuited PEM Fuel Cell without Applying any Electrical Voltage.

    Science.gov (United States)

    Friebe, Sebastian; Geppert, Benjamin; Caro, Jürgen

    2015-06-26

    A short-circuited PEM fuel cell with a Nafion membrane has been evaluated in the room-temperature separation of hydrogen from exhaust gas streams. The separated hydrogen can be recovered or consumed in an in situ olefin hydrogenation when the fuel cell is operated as catalytic membrane reactor. Without applying an outer electrical voltage, there is a continuous hydrogen flux from the higher to the lower hydrogen partial pressure side through the Nafion membrane. On the feed side of the Nafion membrane, hydrogen is catalytically split into protons and electrons by the Pt/C electrocatalyst. The protons diffuse through the Nafion membrane, the electrons follow the short-circuit between the two brass current collectors. On the cathode side, protons and electrons recombine, and hydrogen is released. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Electric Field Modulation of Semiconductor Quantum Dot Photoluminescence: Insights Into the Design of Robust Voltage-Sensitive Cellular Imaging Probes.

    Science.gov (United States)

    Rowland, Clare E; Susumu, Kimihiro; Stewart, Michael H; Oh, Eunkeu; Mäkinen, Antti J; O'Shaughnessy, Thomas J; Kushto, Gary; Wolak, Mason A; Erickson, Jeffrey S; Efros, Alexander L; Huston, Alan L; Delehanty, James B

    2015-10-14

    The intrinsic properties of quantum dots (QDs) and the growing ability to interface them controllably with living cells has far-reaching potential applications in probing cellular processes such as membrane action potential. We demonstrate that an electric field typical of those found in neuronal membranes results in suppression of the QD photoluminescence (PL) and, for the first time, that QD PL is able to track the action potential profile of a firing neuron with millisecond time resolution. This effect is shown to be connected with electric-field-driven QD ionization and consequent QD PL quenching, in contradiction with conventional wisdom that suppression of the QD PL is attributable to the quantum confined Stark effect.

  1. Analysis of Electric Propulsion Performance on Submersible with Motor DC, Supply Power 10260AH at Voltage 115VDC

    Directory of Open Access Journals (Sweden)

    Indra Ranu Kusuma

    2017-03-01

    Full Text Available Electric propulsion is the ship system using propulsion motor to replace performance of main engine. The application of diesel engine as propulsion system have some problems and weaknesses such as diesel engine unability to operate when submersible vessel is operating under sea. To overcome that problems in submersible vessel, alternative solution of ship propulsion is required. DC Motor can be used as this alternative solution. Submersible vessel use electric propulsion system with DC Motor because DC Motor has advantages of easy rotation setting and does not cause noise when submersible vessel is diving. This bachelor thesis will study the application of DC Motor as an electric propulsion system on submersible vessel with length 59,57 m in series and parallel circuit by simulation using MATLAB software. The simulation data obtained are rotation and torque of DC Motor. From these simulation, it can be concluded that parallel circuit rotation is greater than series circuit rotation. It caused the greater speed and lower power in parallel circuit. 

  2. Mitigation of voltage sags in the distribution system with dynamic voltage restorer

    International Nuclear Information System (INIS)

    Viglas, D.; Belan, A.

    2012-01-01

    Dynamic voltage restorer is a custom power device that is used to improve voltage sags or swells in electrical distribution system. The components of the Dynamic Voltage Restorer consist of injection transformers, voltage source inverter, passive filters and energy storage. The main function of the Dynamic voltage restorer is used to inject three phase voltage in series and in synchronism with the grid voltages in order to compensate voltage disturbances. This article deals with mitigation of voltage sags caused by three-phase short circuit. Dynamic voltage restorer is modelled in MATLAB/Simulink. (Authors)

  3. The peculiarities of spectral manifestations of high-voltage electric discharge in different phase states of ion systems.

    Science.gov (United States)

    Gafurov, M M; Aliev, A R; Ataev, M B; Rabadanov, K Sh

    2013-10-01

    The effects of high-voltage pulsed discharge (HVPD activation) on vibrational spectra of ion salt systems have been studied. The peculiarities of spectral display of HVPD in ion melts and aqueous solutions of electrolytes, in ion-conducting phases of crystalline and glassy salt systems have been investigated. After HVPD a salt system is in non-equilibrium activated state. In the activated state of a salt system, the relaxation time of the vibrational excited states of molecular ions is shorter than in the equilibrium state if the vibrational relaxation rate increases with temperature in the system. For those systems for which the relaxation rate decreases at elevated temperatures, the relaxation time of the vibrational excited states of molecular ions is longer than in the equilibrium state. HVPD activation of a salt system can change the configuration of the electron shell of molecular ions. Therefore, the lifetime values of activated state of salt systems are abnormally large. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Evaluation of exercise-induced myocardial stunning by means of immediate post-exercise Tc-99m sestamibi gated SPECT

    International Nuclear Information System (INIS)

    Ouvrier, M.J.; Hitzel, A.; Vera, P.; Manrique, A.; Bernard, M.; Manrique, A.

    2009-01-01

    Aim: Repeated episodes of myocardial stunning may lead to chronic ventricular dysfunction. We attempted to assess the parameters related to post-exercise stunning in patients undergoing gated SPECT. Methods: Six hundred patients undergoing a one-day stress/rest 99m Tc-sestamibi gated SPECT were studied. Stress imaging was acquired within 15 minutes after injection. Summed perfusion scores (S.S.S., S.R.S. and S.D.S.) were calculated using Q.P.S., and L.V. function assessed using Q.G.S.. Stunning was defined as the association of ischemia (S.S.S. = 4 and SDS > 0) and a minimum of 5% decrease in post-stress E.F.. Results: Ischemia was found in 225 (37.5%) patients. Among these, 67 (30%) showed myocardial stunning. Patients with stunning had a lower rest E.S.V. (47 ± 24 ml vs 65 ± 52 ml, p < 0.0003) and E.D.V. (108± 35 ml vs 122 ± 66 ml, p 0.03), an increased rest L.V.E.F. (58 ± 10% vs 52 ± 13%, p < 0.0001) and a decreased post-stress L.V.E.F. (49 ± 10% vs 53 ± 13%, p < 0.02) compared to patients with no stunning. The number of myocardial segments showing reversible perfusion defects was increased in patients with stunning (2.7 ± 2.6 vs 1.7 ± 2.1, p < 0.02). On logistic regression, an extent of ischemia greater than two segments and a rest E.F. greater than 45% were independent predictors of the occurrence of myocardial stunning in patients with ischemia. Conclusions: In patients with ischemia, exercise-induced stunning was associated with an increased extent of ischemia but also preserved rest ventricular function. (authors)

  5. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  6. Conceptual model of a logical system processor of selection to electrical filters for correction of harmonics in low voltage lines

    Science.gov (United States)

    Lastre, Arlys; Torriente, Ives; Méndez, Erik F.; Cordovés, Alexis

    2017-06-01

    In the present investigation, the authors propose a conceptual model for the analysis and the decision making of the corrective models to use in the mitigation of the harmonic distortion. The authors considered the setting of conventional models, and such adaptive models like the filters incorporation to networks neuronal artificial (RNA's) for the mitigating effect. In addition to the present work is a showing of the experimental model that learns by means of a flowchart denoting the need to use artificial intelligence skills for the exposition of the proposed model. The other aspect considered and analyzed are the adaptability and usage of the same, considering a local reference of the laws and lineaments of energy quality that demands the Department of Electricity and Energy Renewable (MEER) of Equator.

  7. Electrical Structure of Future Off-shore Wind Power Plant with a High Voltage Direct Current Power Transmission

    DEFF Research Database (Denmark)

    Sharma, Ranjan

    The increasing demand of electric power and the growing consciousness towards the changing climate has led to a rapid development of renewable energy in the recent years. Among all, wind energy has been the fastest growing energy source in the last decade. But the growing size of wind power plants......, better wind conditions at off-shore and the general demand to put them out of sight have all contributed to the installation of large wind power plants in off-shore condition. However, moving wind power plants far out in the off-shore comes with many associated problems. One of the main challenges...... is the transmission of power over long distance. Historically, the power transmission from off-shore wind power plants has been done via HVAC submarine cables. This provides a simple solution, but AC cables cannot be arbitrarily long. It is shown in the report that major issues with HVAC cable transmission system...

  8. Sensing voltage across lipid membranes

    Science.gov (United States)

    Swartz, Kenton J.

    2009-01-01

    The detection of electrical potentials across lipid bilayers by specialized membrane proteins is required for many fundamental cellular processes such as the generation and propagation of nerve impulses. These membrane proteins possess modular voltage-sensing domains, a notable example being the S1-S4 domains of voltage-activated ion channels. Ground-breaking structural studies on these domains explain how voltage sensors are designed and reveal important interactions with the surrounding lipid membrane. Although further structures are needed to fully understand the conformational changes that occur during voltage sensing, the available data help to frame several key concepts that are fundamental to the mechanism of voltage sensing. PMID:19092925

  9. Recycling ``in situ`` of dielectric oil of electric transformer of medium and high voltage; Reciclaje ``in situ`` y ``en carga`` del aceite dielectrico de los transformadores electricos de media y alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Solis, A.

    1997-06-01

    The author describes the process followed by the company to control the quality of every type of oil from electric transformer of medium and high voltage polluted because of its use. The pollutants contained in the dielectric liquid are eliminated or minimize through the following treatments: conditioning-reconditioning-regeneration. (Author) 6 refs.

  10. The electrical characterization of Ag/PTCDA/PEDOT:PSS/p-Si Schottky diode by current–voltage characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, Muhammad [Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23640 (Pakistan); Department of Physics, Abdul Wali Khan University Mardan, 23200 (Pakistan); Sayyad, Muhammad Hassan; Wahab, Fazal; Khan, Dil Nawaz [Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23640 (Pakistan); Aziz, Fakhra, E-mail: fakhra69@yahoo.com [Department of Electronics, Jinnah College for Women, University of Peshawar, Peshawar 25120 (Pakistan)

    2013-04-15

    The Ag/PTCDA/PEDOT:PSS/p-Si Schottky diode has been fabricated by adding a layer of organic compound 3,4,9,10-perylene tetracarboxylic dianhydride (PTCDA) on top of the p-Si for which the junction characteristics have been investigated. The electronic properties of the device have been studied by the conventional I–V and the Norde's methods. For conventional I–V measurements the rectifying behavior has been observed with a rectification ratio of 236. The barrier height and ideality factor values of 0.81 eV and 3.5, respectively, for the structure have been obtained from the forward bias I–V characteristics. Various electrical parameters such as reverse saturation current, series resistance and shunt resistance have been calculated from the analysis of experimental I–V results and discussed in detail. The barrier height and the series resistance determined by the Norde's function are found in good agreement with the values calculated from conventional I–V measurements. The charge conduction mechanism has also been discussed.

  11. Low-voltage electrically-enhanced microextraction as a novel technique for simultaneous extraction of acidic and basic drugs from biological fluids.

    Science.gov (United States)

    Seidi, Shahram; Yamini, Yadollah; Rezazadeh, Maryam; Esrafili, Ali

    2012-06-22

    In the present work, for the first time a new set-up was presented for simultaneous extraction of acidic and basic drugs using a recent novel electrically-enhanced microextraction technique, termed electromembrane extraction at low voltages followed by high performance liquid chromatography with ultraviolet detection. Nalmefene (NAL) as a basic drug and diclofenac (DIC) as an acidic drug were extracted from 24 mL aqueous sample solutions at neutral pH into 10 μL of each acidified (HCl 50 mM) and basic (NaOH 50 mM) acceptor solution, respectively. Supported liquid membranes including 2-nitrophenyl octyl ether containing 5% di-(2-ethylhexyl) phosphate and 1-octanol were used to ensure efficient extraction of NAL and DIC, respectively. Low voltage of 40 V was applied over the SLMs during 14 min extraction time. The influences of fundamental parameters affecting the transport of target drugs were optimized using experimental design. Under optimal conditions, NAL and DIC were extracted with extraction recoveries of 12.5 and 14.6, respectively, which corresponded to preconcentration factors of 300 and 350, respectively. The proposed technique provided good linearity with correlation coefficient values higher than 0.9956 over a concentration range of 8-500 μg L⁻¹ and 12-500 μg L⁻¹ for NAL and DIC, respectively. Limits of detection and quantifications, and intra-day precisions (n=3) were less than 4 μg L⁻¹, 12 μg L⁻¹, and 10.1%, respectively. Extraction and determination of NAL and DIC in human urine samples were successfully performed. In light of the data obtained in the present work, this new set-up for EME with low voltages has a future potential as a simple, selective, and fast sample preparation technique for simultaneous extraction and determination of acidic and basic drugs in different complicated matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Molecular cloning and analysis of zebrafish voltage-gated sodium channel beta subunit genes: implications for the evolution of electrical signaling in vertebrates

    Directory of Open Access Journals (Sweden)

    Zhong Tao P

    2007-07-01

    Full Text Available Abstract Background Action potential generation in excitable cells such as myocytes and neurons critically depends on voltage-gated sodium channels. In mammals, sodium channels exist as macromolecular complexes that include a pore-forming alpha subunit and 1 or more modulatory beta subunits. Although alpha subunit genes have been cloned from diverse metazoans including flies, jellyfish, and humans, beta subunits have not previously been identified in any non-mammalian species. To gain further insight into the evolution of electrical signaling in vertebrates, we investigated beta subunit genes in the teleost Danio rerio (zebrafish. Results We identified and cloned single zebrafish gene homologs for beta1-beta3 (zbeta1-zbeta3 and duplicate genes for beta4 (zbeta4.1, zbeta4.2. Sodium channel beta subunit loci are similarly organized in fish and mammalian genomes. Unlike their mammalian counterparts, zbeta1 and zbeta2 subunit genes display extensive alternative splicing. Zebrafish beta subunit genes and their splice variants are differentially-expressed in excitable tissues, indicating tissue-specific regulation of zbeta1-4 expression and splicing. Co-expression of the genes encoding zbeta1 and the zebrafish sodium channel alpha subunit Nav1.5 in Chinese Hamster Ovary cells increased sodium current and altered channel gating, demonstrating functional interactions between zebrafish alpha and beta subunits. Analysis of the synteny and phylogeny of mammalian, teleost, amphibian, and avian beta subunit and related genes indicated that all extant vertebrate beta subunits are orthologous, that beta2/beta4 and beta1/beta3 share common ancestry, and that beta subunits are closely related to other proteins sharing the V-type immunoglobulin domain structure. Vertebrate sodium channel beta subunit genes were not identified in the genomes of invertebrate chordates and are unrelated to known subunits of the para sodium channel in Drosophila. Conclusion The

  13. Influence of carbon dioxide stunning procedure on quality of turkey meat.

    Science.gov (United States)

    Mauri, S; Guijarro, A; Avilés, C; Peña, F

    2017-08-01

    1. The objective of this study was to evaluate the effect of sex and gas stunning on quality attributes of turkey breast meat. 2. One hundred B.U.T. Premium turkeys (50 males and 50 females) were divided into four groups of 25 animals and subjected to one of two CO 2 stunning procedures: G1 stepwise (step 1: 30% CO 2 , 15 s; step 2: 55% CO 2 , 40 s; step 3: 70% CO 2 , 45 s) or G2 fixed concentration (80% CO 2 , 100 s). The pH and meat colour at 20 min post-mortem, and pH, colour (L*, a*, b*), water holding capacity (WHC), drip loss (DL), cooking loss (CL) and Warner-Bratzler shear force (WBSF) in breast samples at 24 h and 7 d post-mortem were assessed. 3. There were significant differences between stunning groups for pH, meat colour and CL, whereas no significant differences were found for DL and WBSF. Sex had a significant effect on pH and b* and ageing of meat affected pH, colour coordinates, DL and WBSF. 4. It was concluded that the G2 treatment affected negatively the pH value and colour coordinates. However, G2 stunning affected positively the WHC parameters. Female turkeys had better results than males for pH, and the colour of female turkey breast meat was less yellow than male breast meat.

  14. Use of high concentrations of carbon dioxide for stunning rabbits reared for meat production

    Directory of Open Access Journals (Sweden)

    A. Dalmau

    2016-03-01

    Full Text Available Abstract: An investigation was performed to determine whether high concentrations of carbon dioxide (CO2 at 70-98% in atmospheric air are a suitable alternative for stunning rabbits compared to conventional approaches such as electronarcosis. Aversion to the gas and efficacy in causing prolonged unconsciousness and death were studied in a total of 480 rabbits by means of behavioural parameters, physiological indicators (presence of rhythmic breathing and corneal reflex and electroencephalography (EEG, brain function. The use of any of the 4 studied concentrations of the gas caused more nasal discomfort and vocalisations than the use of atmospheric air (P<0.001. EEG activity confirmed that loss of posture is a good indicator of the onset of unconsciousness in rabbits exposed to CO2, occurring earlier (P<0.05 at 90 and 98% than at 70 and 80%. Rabbits showed signs of aversion for 15 s before the onset of unconsciousness, which occurred around 30 s after the beginning of the exposure to the gas, similar to species such as swine in which high concentrations of CO2 are also used for stunning. CO2 at 80 to 98% is suggested as a reasonable concentration range to induce a long state of unconsciousness and death in rabbits, while 70% CO2 is not recommended because it requires too long duration of exposure (more than 360 s to ensure effectiveness. Despite the advantages in terms of pre-stun handling and irreversibility, CO2 is not free of animal welfare concerns. In consequence, a debate is necessary to ascertain if CO2 can be considered a suitable alternative to stun rabbits, considering the advantages and drawbacks cited, quantified in the present study as 15 s of aversion (nasal discomfort and vocalisations before losing posture.

  15. Electric Substations

    Data.gov (United States)

    Department of Homeland Security — Substations. Substations are facilities and equipment that switch, transform, or regulate electric voltage. The Substations feature class includes taps, a location...

  16. Milrinone and levosimendan administered after reperfusion improve myocardial stunning in swine.

    Science.gov (United States)

    Shibata, Itsuko; Cho, Sungsam; Yoshitomi, Osamu; Ureshino, Hiroyuki; Maekawa, Takuji; Hara, Tetsuya; Sumikawa, Koji

    2013-02-01

    We assessed the effect of milrinone application timing after reperfusion against myocardial stunning as compared with levosimendan in swine. Furthermore, we examined the role of p38 mitogen-activated protein kinase (p38 MAPK) in the milrinone-induced cardioprotection. All swine were subjected to 12-minutes ischemia followed by 90-minutes reperfusion to generate stunned myocardium. Milrinone or levosimendan was administered intravenously either for 20 minutes starting just after reperfusion or for 70 minutes starting 20 minutes after reperfusion. In another group, SB203580, a selective p38 MAPK inhibitor, was administered with and without milrinone. Regional myocardial contractility was assessed by percent segment shortening (%SS). Milrinone starting just after reperfusion, but not starting 20 minutes after reperfusion, improved %SS at 30, 60, and 90 minutes after reperfusion compared with that in the control group. SB203580 abolished the beneficial effect of milrinone. On the other hand, levosimendan starting 20 minutes after reperfusion, but not for 20 minutes starting just after reperfusion, improved %SS at 60 and 90 minutes after reperfusion. Milrinone should be administered just after reperfusion to protect myocardial stunning through p38 MAPK, whereas levosimendan improvement of contractile function could be mainly dependent on its positive inotropic effect.

  17. Low Wind Speed Turbine Project Phase II: The Application of Medium-Voltage Electrical Apparatus to the Class of Variable Speed Multi-Megawatt Low Wind Speed Turbines; 15 June 2004--30 April 2005

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, W.; Behnke, M.

    2005-11-01

    Kilowatt ratings of modern wind turbines have progressed rapidly from 50 kW to 1,800 kW over the past 25 years, with 3.0- to 7.5-MW turbines expected in the next 5 years. The premise of this study is simple: The rapid growth of wind turbine power ratings and the corresponding growth in turbine electrical generation systems and associated controls are quickly making low-voltage (LV) electrical design approaches cost-ineffective. This report provides design detail and compares the cost of energy (COE) between commercial LV-class wind power machines and emerging medium-voltage (MV)-class multi-megawatt wind technology. The key finding is that a 2.5% reduction in the COE can be achieved by moving from LV to MV systems. This is a conservative estimate, with a 3% to 3.5% reduction believed to be attainable once purchase orders to support a 250-turbine/year production level are placed. This evaluation considers capital costs as well as installation, maintenance, and training requirements for wind turbine maintenance personnel. Subsystems investigated include the generator, pendant cables, variable-speed converter, and padmount transformer with switchgear. Both current-source and voltage-source converter/inverter MV topologies are compared against their low-voltage, voltage-source counterparts at the 3.0-, 5.0-, and 7.5-MW levels.

  18. Cathodic voltage-controlled electrical stimulation of titanium for prevention of methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii biofilm infections.

    Science.gov (United States)

    Canty, Mary; Luke-Marshall, Nicole; Campagnari, Anthony; Ehrensberger, Mark

    2017-01-15

    Antibiotic resistance of bacterial biofilms limits available treatment methods for implant-associated orthopaedic infections. This study evaluated the effects of applying cathodic voltage-controlled electrical stimulations (CVCES) of -1.5V and -1.8V (vs. Ag/AgCl) to coupons of commercially pure titanium (cpTi) incubated in cultures of methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii (A. baumannii) as a method of preventing bacterial attachment. Stimulations were applied for 2, 4, and 8h and coupon-associated and planktonic colony-forming units (CFU) were enumerated following stimulation. Compared to open circuit potential (OCP) controls, CVCES for 4h at -1.8V significantly reduced coupon-associated MRSA CFU by 99.9% (1.30×10 4 vs. 4.45×10 7 , p=0.047) and A. baumannii coupon-associated CFU by 99.9% (1.64×10 4 vs. 5.93×10 7 , p=0.001) and reduced planktonic CFU below detectable levels for both strains. CVCES at -1.8V for 8h also reduced coupon-associated and planktonic CFU below detectable levels for each strain. CVCES at -1.5V for 4 and 8h, and -1.8V for 2h did not result in clinically relevant reductions. For 4 and 8h stimulations, the current density was significantly higher for -1.8V than -1.5V, an effect directly related to the rate of water and oxygen reduction on the cpTi surface. This significantly increased the pH, a suspected influence in decreased CFU viability. The voltage-dependent electrochemical properties of cpTi likely contribute to the observed antimicrobial effects of CVCES. This study revealed that CVCES of titanium could prevent coupon-associated and planktonic CFU of Gram-positive MRSA and Gram-negative A. baumannii from reaching detectable levels in a magnitude-dependent and time-dependent manner. Periprosthetic joint infection is a devastating outcome of total joint arthroplasty and has led to increased patient morbidity and rising healthcare costs. Current treatments are limited by the growing prevalence of

  19. Proposal for the award of an industrial services contract for electrical installation work and maintenance of lighting and low-voltage distribution

    CERN Document Server

    2000-01-01

    This document concerns the award of an Industrial Services contract for electrical installation work and maintenance of lighting and low-voltage distribution. Following a market survey carried out among 127 firms in fifteen Member States, a call for tenders (IT-2754/ST) was sent on 2 June 2000 to three firms and four consortia, each consisting of two firms, in four Member States. By the closing date, CERN had received tenders from two firms and two consortia in four Member States. The Finance Committee is invited to agree to the negotiation of a contract with the consortium SPIE TRINDEL(FR) ? CONTROLMATIC (DE), the lowest bidder complying with the specified requirements, for an initial period of three years from 1 July 2001 for a total amount of 41 705 497 Swiss francs, not subject to revision until 31 December 2003. The contract will include options for two one-year extensions beyond the initial three-year period for a total amount of 27 803 664 Swiss francs, for which CERN will seek approval by the Finance ...

  20. Constant DC-Capacitor Voltage-Control-Based Harmonics Compensation Strategy of Smart Charger for Electric Vehicles in Single-Phase Three-Wire Distribution Feeders

    Directory of Open Access Journals (Sweden)

    Fuka Ikeda

    2017-06-01

    Full Text Available This paper discusses harmonic current compensation of the constant DC-capacitor voltage-control (CDCVC-based strategy of smart chargers for electric vehicles (EVs in single-phase three-wire distribution feeders (SPTWDFs under nonlinear load conditions. The basic principle of the CDCVC-based harmonics compensation strategy under nonlinear load conditions is discussed in detail. The instantaneous power flowing into the three-leg pulse-width modulated (PWM rectifier, which performs as a smart charger, shows that the CDCVC-based strategy achieves balanced and sinusoidal source currents with a unity power factor. The CDCVC-based harmonics compensation strategy does not require any calculation blocks of fundamental reactive, unbalanced active, and harmonic currents. Thus, the authors propose a simplified algorithm to compensate for reactive, unbalanced active, and harmonic currents. A digital computer simulation is implemented to confirm the validity and high practicability of the CDCVC-based harmonics compensation strategy using PSIM software. Simulation results demonstrate that balanced and sinusoidal source currents with a unity power factor in SPTWDFs are obtained on the secondary side of the pole-mounted distribution transformer (PMDT during both the battery-charging and discharging operations in EVs, compensating for the reactive, unbalanced active, and harmonic currents.

  1. Electric Company - Medium Voltage Substations

    OpenAIRE

    MacCosham, Spencer

    2014-01-01

    The capstone project goal was to recommend ways to increase sales of our client’s product by a factor of 10. The core of our project included researching and analyzing the client’s “Model III” package-unit-substations. Specifically, the project objectives were two-fold: First, we were to conduct market research and data analysis on package unit substations in North America. We needed to identify sales channels, competitors, potential substitutes, etc. Second, we were to identify market/channe...

  2. Service tests of voltage detectors - an essential requirement for working without accidents in electricity installations with nominal voltage > 1 kV; Wiederholungspruefungen an Spannungspruefern. Eine wesentliche Voraussetzung fuer das unfallfreie Arbeiten in elektrischen Anlagen mit Nennspannungen > 1 kV

    Energy Technology Data Exchange (ETDEWEB)

    Lange, G. [VEW Eurotest GmbH, Dortmund (Germany); Emmer, H. [Bayernwerk AG Muenchen (Germany); Schuhmann, J. [Bayernwerk Hochspannungsnetz GmbH Nuernberg (Germany); Grab, E. [Bewag-AG, Berlin (Germany); Krebeck, N. [RWE Energie AG, RV Nike, Osnabrueck (Germany); Rodwald, R. [Schleswag AG, Rendsburg (Germany); Schlegel, B. [Stadtwerke Muenchen GmbH (Germany)

    1999-03-22

    The function of voltage detectors is an important requirement for working without accidents in electricity installations. For this reason the required service tests, described in VDE and VBG 4, are essential to receive a secure function of the voltage detector over its service time. The results of the statistical evaluation of 10.000 service tests in test fields of electricity utilities document the importance of these tests. (orig.) [Deutsch] Die Funktionsfaehigkeit von Spannungspruefern ist eine wesentliche Voraussetzung fuer das unfallfreie Arbeiten in elektrischen Anlagen. Aus diesem Grunde stellen die in den VDE-Bestimmungen und in der VBG 4 festgelegten Wiederholungspruefungen eine unersetzliche Massnahme zur Erhaltung der Funktionsfaehigkeit dar. Die Ergebnisse der statistischen Auswertung von 10 000 Wiederholungspruefungen in Prueffeldern von Energieversorgungsunternehmen unterstreichen die Wichtigkeit dieser Pruefungen. (orig.)

  3. Effect of high-voltage electrical stimulation on the albumin and histamine serum concentrations, edema, and pain in acute joint inflammation of rats

    Directory of Open Access Journals (Sweden)

    Maria C. Sandoval

    2015-04-01

    Full Text Available BACKGROUND: The mechanism by which high-voltage electrical stimulation (HVPC acts on edema reduction is unknown. OBJECTIVE: To assess the effect of HVPC with negative polarity (- applied to the ankle of rats with acute joint inflammation. METHOD: Sixty-four rats were divided into four groups (n=16: inflamed+HVPC(-, 0.03 mL application of ι-carrageenan (3% to the tibiotarsal joint plus HVPC(-; inflamed+HVPC placebo, carrageenan application and HVPC placebo; normal+HVPC(-, HVPC application(-; and normal control, no intervention. The HVPC(- 100 Hz at a submotor level was applied daily for 45 min on three consecutive days. The variables were pain, hind-foot volume, and serum histamine and albumin assessed before and during the 48 hours following inflammation. The variables were compared using the t test, one-way ANOVA, nested ANOVA for repeated measures, and the post hoc Bonferroni test. Analysis of covariance was applied to adjust the effects of HVPC(- by measurements of pain, inflammation, albumin, and histamine at 24 h, and the final weight was compared to the other groups. The significance level was set at p0.05. Albumin was reduced in the groups that received the intervention, but there was no differences between them. There was only a 24 hour increase in histamine with the normal+HVPC(- (p=0.0001 and inflamed+HVPC placebo groups (p=0.01 compared to the normal control group. CONCLUSIONS: The results of the present study suggest that HVPC(- with the parameters employed did not reduce pain or edema and did not change serum albumin or histamine levels,, which indicates the inability of this resource to have a positive effect when treating treat acute joint inflammation.

  4. Determination of the threshold-energy surface for copper using in-situ electrical-resistivity measurements in the high-voltage electron microscope

    International Nuclear Information System (INIS)

    King, W.E.; Merkle, K.L.; Meshii, M.

    1981-01-01

    A detailed study of the anisotropy of the threshold energy for Frenkel-pair production in copper was carried out experimentally, using in-situ electrical-resistivity measurements in the high-voltage electron microscope. These electrical-resistivity measurements, which are sensitive to small changes in point-defect concentration, were used to determine the damage or defect production rate. Damage-rate measurements in copper single crystals were carried out for approx.40 incident electron-beam directions and six electron energies from 0.4 to 1.1 MeV. The total cross section for Frenkel-pair production is proportional to the measured damage rate and can be theoretically calculated if the form of the threshold-energy surface is known. Trial threshold-energy surfaces were systematically altered until a ''best fit'' of the calculated to the measured total cross sections for Frenkel-pair production was obtained. The average threshold energy of this surface is 28.5 eV. The minimum threshold energy is 18 +- 2 eV and is located near . A ring of very high threshold energy (>50 eV) surrounds the direction. A damage function for single-defect production was derived from this surface and was applied to defect-production calculations at higher recoil energies. This function rises rather sharply from a value of zero at 17 eV to 0.8 at 42 eV. It has the value of 0.5 at 24.5 eV. Above 30 eV the slope of the curve begins to decrease, reflecting the presence of the high-energy regions of the threshold-energy surface. Both topographical and quantitative comparisons of the present surface with those in the literature were presented. Based on a chi 2 goodness-of-fit test, the present surface was found to predict the experimentally observed total cross sections for Frenkel-pair production significantly better than the other available surfaces. Also, the goodness of fit varied substantially less with energy and direction for the present surface

  5. Non-isolated DC-AC converter with high voltage gain for autonomous systems of electric power; Conversor CC-CA nao isolado com alto ganho de tensao para aplicacao em sistemas autonomos de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, George Cajazeiras [Centro Federal de Educacao Tecnologica do Ceara (CEFET/CE), Fortaleza, CE (Brazil); Torrico-Bascope, Rene P. [Universidade Federal do Ceara (PPGEE/UFC), Fortaleza, CE (Brazil). Programa de Pos Graduacao em Engenharia Eletrica; Borges Neto, Manuel Rangel [Centro Federal de Educacao Tecnologica de Petrolina (CEFET-PET), PE (Brazil)

    2008-07-01

    A non-isolated DC-AC converter with high voltage gain with two output sinusoidal voltage - 110 V and 220 V - and frequency 60 Hz for application in autonomous systems of electric power is proposed in this work. This topology consists of a boost converter with high voltage gain, based on three-state switching cell combined with a double half bridge inverter. This configuration type the size and the cost are reduced and the efficiency is gotten better, due to the reduced number of switches. The converters that compose this topology operate with high frequency, reducing the volume of the magnetic materials. can be mention as important characteristics: the voltage stress across the switches of the boost converter are low, due they be naturally clamped by one output filter capacitor, which allows the utilization of switches with lower conduction resistances, and the waveforms of the output voltage of the double half bridge inverter supplies for the load it is sinusoidal and it possesses low harmonic content. (author)

  6. Corticosterone and thyroxine in cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii).

    Science.gov (United States)

    Hunt, Kathleen E; Innis, Charles; Rolland, Rosalind M

    2012-09-01

    Kemp's ridley sea turtles (Lepidochelys kempii), a critically endangered species, frequently strand on the shores of Cape Cod (Massachusetts, USA) in late autumn in a state of "cold-stunning" exhibiting low body temperature and related clinical issues. Stranded turtles are transported to the New England Aquarium (Boston, Massachusetts, USA) for treatment and rehabilitation. This study tested the hypothesis that cold-stunned sea turtles might exhibit high corticosterone ("stress hormone") or low thyroxine (which is often affected by temperature), or both, and that monitoring of both hormones may be useful for assessing recovery. In a retrospective analysis, 87 archived plasma samples were assayed from 56 cold-stunned juvenile Kemp's ridley sea turtles for corticosterone and free thyroxine (fT4). Upon admission, mean corticosterone was the highest yet reported for a population of sea turtles (39.3 +/- 2.5 ng/ml; mean +/- standard error of the mean [SEM]) and fT4 was usually undetectable. On admission, corticosterone was negatively correlated with white blood cell count but was not correlated with blood glucose. There were no differences in either hormone between survivors and nonsurvivors on admission. After 18+ days in recovery, surviving turtles' corticosterone dropped significantly to levels typical of baseline in other species (0.9 +/- 1.0 ng/ml) while fT4 increased significantly (1.3 +/- 1.5 pg/ml). During recovery, corticosterone was positively correlated with blood glucose and was not correlated with white blood cell count. Turtles that showed persistent deficits in feeding, activity, or both during recovery had significantly lower fT4 than did turtles with no such deficits. The "high corticosterone, low fT4" endocrine profile seen on admission may be a useful marker of cold-stunning in this and other species. Further studies are necessary to determine whether low thyroid hormones play a causal role in deficits in feeding and activity during recovery

  7. Integrated genomics and proteomics of the Torpedo californica electric organ: concordance with the mammalian neuromuscular junction

    Directory of Open Access Journals (Sweden)

    Mate Suzanne E

    2011-05-01

    Full Text Available Abstract Background During development, the branchial mesoderm of Torpedo californica transdifferentiates into an electric organ capable of generating high voltage discharges to stun fish. The organ contains a high density of cholinergic synapses and has served as a biochemical model for the membrane specialization of myofibers, the neuromuscular junction (NMJ. We studied the genome and proteome of the electric organ to gain insight into its composition, to determine if there is concordance with skeletal muscle and the NMJ, and to identify novel synaptic proteins. Results Of 435 proteins identified, 300 mapped to Torpedo cDNA sequences with ≥2 peptides. We identified 14 uncharacterized proteins in the electric organ that are known to play a role in acetylcholine receptor clustering or signal transduction. In addition, two human open reading frames, C1orf123 and C6orf130, showed high sequence similarity to electric organ proteins. Our profile lists several proteins that are highly expressed in skeletal muscle or are muscle specific. Synaptic proteins such as acetylcholinesterase, acetylcholine receptor subunits, and rapsyn were present in the electric organ proteome but absent in the skeletal muscle proteome. Conclusions Our integrated genomic and proteomic analysis supports research describing a muscle-like profile of the organ. We show that it is a repository of NMJ proteins but we present limitations on its use as a comprehensive model of the NMJ. Finally, we identified several proteins that may become candidates for signaling proteins not previously characterized as components of the NMJ.

  8. Macroeconomic Assessment of Voltage Sags

    Directory of Open Access Journals (Sweden)

    Sinan Küfeoğlu

    2016-12-01

    Full Text Available The electric power sector has changed dramatically since the 1980s. Electricity customers are now demanding uninterrupted and high quality service from both utilities and authorities. By becoming more and more dependent on the voltage sensitive electronic equipment, the industry sector is the one which is affected the most by voltage disturbances. Voltage sags are one of the most crucial problems for these customers. The utilities, on the other hand, conduct cost-benefit analyses before going through new investment projects. At this point, understanding the costs of voltage sags become imperative for planning purposes. The characteristics of electric power consumption and hence the susceptibility against voltage sags differ considerably among different industry subsectors. Therefore, a model that will address the estimation of worth of electric power reliability for a large number of customer groups is necessary. This paper introduces a macroeconomic model to calculate Customer Voltage Sag Costs (CVSCs for the industry sector customers. The proposed model makes use of analytical data such as value added, annual energy consumption, working hours, and average outage durations and provides a straightforward, credible, and easy to follow methodology for the estimation of CVSCs.

  9. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical

  10. Industrial dry electro-stunning followed by chilling and decapitation as a slaughter method in Claresse (Heteroclarias sp.) and African catfish (Clarius gariepinus)

    NARCIS (Netherlands)

    Sattari, A.; Lambooij, E.; Sharifi, H.; Abbink, W.; Reimert, H.; Vis, van de J.W.

    2010-01-01

    This study evaluated the industrial application of dry electro-stunning for Claresse® and African catfish via monitoring of brain and heart activities, behavioral responses to noxious stimuli and meat quality. Dry electro-stunning (150 V, AC + DC, 100 Hz) of Claresse® for 0.7 ± 0.2 s (mean ± SD)

  11. Análisis estadístico de la caída de tensión en un sistema eléctrico de baja tensión: Statistical analysis of the voltage drop in a low voltage electrical system

    Directory of Open Access Journals (Sweden)

    Juan M. Astorga Gómez

    2013-06-01

    Full Text Available En este trabajo se presenta un enfoque estadístico para la evaluación de la caída de tensión en un sistema eléctrico de baja tensión, basado en la aplicación de dos herramientas básicas del control estadístico de procesos conocidas como cartas de control y análisis de capacidad de procesos. Se muestran los resultados para dos sistemas de prueba, se realizan las pruebas de normalidad y autocorrelación parcial para las muestras, se interpretan los resultados de las cartas de control Xbarra-S y se evalúa la capacidad del proceso considerando las bases del mejoramiento de la calidad. Los sistemas de prueba usados en este trabajo son un sistema eléctrico monofásico de baja tensión y un sistema eléctrico trifásico de baja tensión. El objetivo principal de este trabajo es evaluar el estado de control estadístico de la variable de proceso “caída de tensión”, como herramienta para el mejoramiento continuo de los procesos eléctricos.This paper presents a statistical approach for the evaluation of the voltage drop in a low voltage electrical system, based on the application of two basic tools of statistical process control known as control charts and process capability analysis. The results for two test systems are shown, testing of normality and partial autocorrelation for samples are performed, the results of the control charts Xbar-S are interpreted and the process capability analysis are assessed considering the foundations for the quality improvement. The test systems used in this work are one electrical system single-phase low voltage and one electrical system of three-phase low voltage. The main objective of this paper is to evaluate the state of statistical control of the process variable "voltage drop", as a tool for continuous improvement of the electrical process.

  12. Análisis estadístico de la caída de tensión en un sistema eléctrico de baja tensión; Statistical analysis of the voltage drop in a low voltage electrical system

    Directory of Open Access Journals (Sweden)

    Juan M. Astorga Gómez

    2013-06-01

    Full Text Available En este trabajo se presenta un enfoque estadístico para la evaluación de la caída de tensión en un sistema eléctrico de baja tensión, basado en la aplicación de dos herramientas básicas del control estadístico de procesos conocidas como cartas de control y análisis de capacidad de procesos. Se muestran los resultados para dos sistemas de prueba, se realizan las pruebas de normalidad y autocorrelación parcial para las muestras, se interpretan los resultados de las cartas de control Xbarra-S y se evalúa la capacidad del proceso considerando las bases del mejoramiento de la calidad. Los sistemas de prueba usados en este trabajo son un sistema eléctrico monofásico de baja tensión y un sistema eléctrico trifásico de baja tensión. El objetivo principal de este trabajo es evaluar el estado de control estadístico de la variable de proceso “caída de tensión”, como herramienta para el mejoramiento continuo de los procesos eléctricos.  This paper presents a statistical approach for the evaluation of the voltage drop in a low voltage electrical system, based on the application of two basic tools of statistical process control known as control charts and process capability analysis. The results for two test systems are shown, testing of normality and partial autocorrelation for samples are performed, the results of the control charts Xbar-S are interpreted and the process capability analysis are assessed considering the foundations for the quality improvement. The test systems used in this work are one electrical system single-phase low voltage and one electrical system of three-phase low voltage. The main objective of this paper is to evaluate the state of statistical control of the process variable "voltage drop", as a tool for continuous improvement of the electrical process.

  13. Increase in the number of distributed power generation installations in electricity distribution grids - Simulation in a 16 kV medium-voltage network; Zunahme der dezentralen Energieerzeugungsanlagen in elektrischen Verteilnetzen: Simulationen im 16 kV Mittelspannungsnetz des AEW

    Energy Technology Data Exchange (ETDEWEB)

    Hoeckel, M.; Luechinger, P.

    2003-07-01

    This is the seventh part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This sixth appendix to the main report presents and discusses the results of simulations made on the basis of the real-life 16 kV medium-voltage distribution network operated by the Aargovian electricity utility AEW. This appendix describes the simulation methods used and the basic characteristics of medium-voltage networks and distributed generation facilities. Different types of load profiles, including domestic and industrial loads, are discussed. The results of the simulations are presented in graphical form and provide profiles of voltage and current, active and reactive power and further mains characteristics for varying load conditions. Also, daily profiles for situations with and without distributed generation are presented and short-circuit simulations and grid dynamics are discussed.

  14. Transient voltage oscillations in coils

    International Nuclear Information System (INIS)

    Chowdhuri, P.

    1985-01-01

    Magnet coils may be excited into internal voltage oscillations by transient voltages. Such oscillations may electrically stress the magnet's dielectric components to many times its normal stress. This may precipitate a dielectric failure, and the attendant prolonged loss of service and costly repair work. Therefore, it is important to know the natural frequencies of oscillations of a magnet during the design stage, and to determine whether the expected switching transient voltages can excite the magnet into high-voltage internal oscillations. The series capacitance of a winding significantly affects its natural frequencies. However, the series capacitance is difficult to calculate, because it may comprise complex capacitance network, consisting of intra- and inter-coil turn-to-turn capacitances of the coil sections. A method of calculating the series capacitance of a winding is proposed. This method is rigorous but simple to execute. The time-varying transient voltages along the winding are also calculated

  15. Electricity

    CERN Document Server

    Basford, Leslie

    2013-01-01

    Electricity Made Simple covers the fundamental principles underlying every aspect of electricity. The book discusses current; resistance including its measurement, Kirchhoff's laws, and resistors; electroheat, electromagnetics and electrochemistry; and the motor and generator effects of electromagnetic forces. The text also describes alternating current, circuits and inductors, alternating current circuits, and a.c. generators and motors. Other methods of generating electromagnetic forces are also considered. The book is useful for electrical engineering students.

  16. Neuro-fuzzy-wavelet network for detection and classification of the voltage disturbances in electrical power system; Rede neuro-fuzzy-wavelet para deteccao e classificacao de anomalias de tensao em sistemas eletricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Malange, Fernando C.V. [Universidade do Estado de Mato Grosso (UEMT), Caceres, MT (Brazil). Dept. de Computacao], E-mail: fmalange@gmail.com; Minussi, Carlos R. [Universidade Estadual Paulista (UNESP), Ilha Solteira, SP (Brazil). Dept. de Engenharia Eletrica], E-mail: minussi@dee.feis.unesp.br

    2009-07-01

    A methodology for identifying and classifying voltage disturbances (harmonics, voltage sag, etc.) using fuzzy ARTMAP neural networks is presented. It is an ART (adaptive resonance theory) architecture family neural network that presents the stability and plasticity properties, which are fundamental requests for developing a reliable electrical systems with reduced processing time. Stability means a guarantee of good solutions; plasticity allows realize the training without restart the system every time there are new patterns to be stored in a weight matrix of the neural network. The training is realized from the wave forms provided by the acquisition data system, using the wavelets theory to generate the coefficients that constitute the input patterns of the neural network. Results from simulations show that the accuracy index is nearly 100%. (author)

  17. Power-MOSFET Voltage Regulator

    Science.gov (United States)

    Miller, W. N.; Gray, O. E.

    1982-01-01

    Ninety-six parallel MOSFET devices with two-stage feedback circuit form a high-current dc voltage regulator that also acts as fully-on solid-state switch when fuel-cell out-put falls below regulated voltage. Ripple voltage is less than 20 mV, transient recovery time is less than 50 ms. Parallel MOSFET's act as high-current dc regulator and switch. Regulator can be used wherever large direct currents must be controlled. Can be applied to inverters, industrial furnaces photovoltaic solar generators, dc motors, and electric autos.

  18. Stakeholder involvement in other sectors. High Voltage Electricity Transmission. Case study: CO_2 capture and storage. Common misconceptions on stakeholder involvement - Reviewing deployment of RES

    International Nuclear Information System (INIS)

    Wolsink, Maarten; Komendantova, Nadejda; Kalaydjian, Francois

    2017-01-01

    Session 7 featured several speakers with expertise outside of the nuclear field. High-voltage electricity transmission and carbon capture and storage projects were presented by experts who study and advise on stakeholder involvement in such activities. The session chair provided an overview of stakeholder involvement fundamentals as applied to renewable energy projects. Though the presentations were on non-nuclear projects, the principles presented and discussed were clearly applicable in nuclear contexts as well. Mr Wolsink of University of Amsterdam re-framed the topic of the power supply system as a 'socio-technical system'. He identified three types or levels of societal acceptance for energy innovation: socio-political acceptance, market acceptance and community acceptance. This distinction highlights the different nature of questions, issues, set of actors and challenges that arise at different points or forums around energy infrastructure projects and why general favorability towards a technology does not translate into support of its local implementation. Societal acceptance probably cannot be acquired without meaningful involvement. Arnstein's 'ladder of citizen participation' was referenced by two session speakers. Mr Wolsink explained that inexperienced organisations may target 'consultation', thinking that this is real participation. However, consultation is a relatively low level of involvement which consists of gathering information or views, without promoting two-way dialogue (engagement) or committing to actual influence and indeed some degree of citizen power. He advised that simple consultation should be avoided unless the organisation finds that such stakeholder or public input is essential to the decision and intends to give it due account. The Barendrecht case on carbon capture and storage, as presented by Mr Kalaydjian of IFP Energies Nouvelles, illustrates the danger in overly restricting or compartmentalising stakeholder involvement. Ms

  19. Space Life Sciences Directorate's Position on the Physiological Effects of Exposing the Crewmemeber to Low-Voltage Electrical Hazards During Extravehicular Activity

    Science.gov (United States)

    Hamilton, Douglas; Kramer, Leonard; Mikatarian, Ron; Polk, James; Duncan, Michael; Koontz, Steven

    2010-01-01

    The models predict that, for low voltage exposures in the space suit, physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work with Naval Health Research Center Detachment Directed Energy Bio-effects Laboratory is being proposed to analyze additional current paths across the human torso and upper limbs. These models may need to be verified with human studies.

  20. 99mTc-glucarate kinetics differentiate normal, stunned, hibernating, and nonviable myocardium in a perfused rat heart model

    International Nuclear Information System (INIS)

    Okada, David R.; Liu, Zhonglin; Johnson, Gerald; Okada, Robert D.; Beju, Delia; Khaw, Ban An

    2010-01-01

    99m Tc-glucarate is an infarct-avid imaging agent. However, patients may have mixtures of normal, irreversibly injured, stunned, and hibernating myocardium. The purposes were to determine 99m Tc-glucarate uptake and clearance kinetics in these four conditions, and its ability to determine the extent of injury. Twenty-two perfused rat hearts were studied: controls (n = 5), stunned (n = 5; 20-min no-flow followed by 5-min reflow), hibernating (n = 6; 120-min low flow at 4 ml/min), and ischemic-reperfused (n = 6; 120-min no-flow followed by reflow). 99m Tc-glucarate was then infused. Tracer activity was monitored using a NaI scintillation detector and a multichannel analyzer. Creatine kinase, electron microscopy, and triphenyltetrazolium chloride determined viability. 99m Tc-glucarate 10-min myocardial uptake was significantly greater in ischemic-reperfused (2.50 ± 0.09) (cpm, SEM) than in control (1.74 ± 0.07), stunned (1.68 ± 0.11), and hibernating (1.59 ± 0.11) (p 99m Tc-glucarate 60-min myocardial uptake was significantly greater in ischemic-reperfused (7.60 ± 0.63) than in control (1.98 ± 0.15), stunned (1.79 ± 0.08), and hibernating (2.33 ± 0.15) (p 99m Tc-glucarate activity continually and progressively increased in irreversibly injured myocardium. 99m Tc-glucarate uptake was strongly correlated with myocardial necrosis as determined by three independent assessments of viability. There were minimal and similar 99m Tc-glucarate uptakes in control, stunned, and hibernating myocardium. (orig.)

  1. Sperm whale predator-prey interactions involve chasing and buzzing, but no acoustic stunning

    DEFF Research Database (Denmark)

    Fais, Andrea; Johnson, M.; Wilson, Maria

    2016-01-01

    The sperm whale carries a hypertrophied nose that generates powerful clicks for long-range echolocation. However, it remains a conundrum how this bizarrely shaped apex predator catches its prey. Several hypotheses have been advanced to propose both active and passive means to acquire prey......, including acoustic debilitation of prey with very powerful clicks. Here we test these hypotheses by using sound and movement recording tags in a fine-scale study of buzz sequences to relate the acoustic behaviour of sperm whales with changes in acceleration in their head region during prey capture attempts....... We show that in the terminal buzz phase, sperm whales reduce inter-click intervals and estimated source levels by 1-2 orders of magnitude. As a result, received levels at the prey are more than an order of magnitude below levels required for debilitation, precluding acoustic stunning to facilitate...

  2. Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise

    International Nuclear Information System (INIS)

    Hashimoto, Jun; Kubo, Atsushi; Iwasaki, Ryuichiro; Iwanaga, Shiro; Mitamura, Hideo; Ogawa, Satoshi; Kosuda, Shigeru

    1999-01-01

    This study was designed to apply ECG-gating to stress myocardial perfusion single-photon emission tomography (SPET) for the evaluation of myocardial stunning after exercise. Technetium-99m sestamibi was selected as the perfusion agent and a rest/exercise 1-day protocol was employed. Fourteen patients without coronary stenosis and 33 patients with coronary stenosis were enrolled in the study. We carried out three data acquisitions with ECG-gating: a 15-min data acquisition starting 30 min after the rest injection (AC1), a 5-min acquisition starting 5 min after the stress injection (AC2) and a 15-min acquisition starting 20 min after the stress injection (AC3). Calculation of left ventricular ejection fraction (LVEF) values was performed by means of automatic determination of the endocardial surface for all gating intervals in the cardiac cycle. Measured global EF values in 14 patients without coronary stenosis were 52.3%±7.6% (AC1), 60.6%±8.9% (AC2) and 55.6%±5.6% (AC3), and those in 11 patients with severe ischaemia were 53.6%±8.0% (AC1), 45.6%±12.1% (AC2) and 49.7%±10.7%. The magnitude of the depression of post-stress LVEF relative to the rest LVEF correlated with the severity of ischaemia (r=0.594, P=0.002), and segments manifesting post-stress functional depression were associated with ischaemic segments showing reversible perfusion defects. Stress myocardial perfusion SPET with ECG-gating is a feasible method for the evaluation of myocardial stunning as well as exercise-induced ischaemia. (orig.)

  3. Physiological responses to low atmospheric pressure stunning and the implications for welfare.

    Science.gov (United States)

    McKeegan, D E F; Sandercock, D A; Gerritzen, M A

    2013-04-01

    In low atmospheric pressure stunning (LAPS), poultry are rendered unconscious before slaughter by gradually reducing oxygen tension in the atmosphere to achieve a progressive anoxia. The effects of LAPS are not instantaneous, so there are legitimate welfare concerns around the experience of birds before loss of consciousness. Using self-contained telemetry logging units, high-quality continuous electroencephalogram (EEG) and electrocardiogram (EKG) recordings were obtained from 28 broiler chickens during exposure to LAPS in a commercial poultry processing plant. Application of LAPS was associated with changes in the EEG pattern in the form of increases in total power, decreases in mean frequency, and in particular, increases in slow-wave (delta) activity, indicating a gradual loss of consciousness. Increased delta wave activity was seen within 10 s of LAPS onset and consistently thereafter, peaking at 30 s into LAPS at which point the EEG signal shared characteristics with that of birds in a surgical plane of anesthesia. During LAPS, heart rate consistently decreased, with more pronounced bradycardia and arrhythmia observed after 30 s. No heart rate increases were observed in the period when the birds were potentially conscious. After an initial quiescent period, brief body movements (presumed to be ataxia/loss of posture) were seen on average at 39 s into the LAPS process. Later (after 120 s on average), artifacts related to clonic (wing flapping) and tonic (muscle spasms) convulsions were observed in the EKG recordings. Based on EEG analysis and body movement responses, a conservative estimate of time to loss of consciousness is approximately 40 s. The lack of behavioral responses indicating aversion or escape and absence of heart rate elevation in the conscious period strongly suggest that birds do not find LAPS induction distressing. Collectively, the results suggest that LAPS is a humane approach that has the potential to improve the welfare of poultry at

  4. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  5. Electric power quality analysis methods. Application to voltage dips and harmonic disturbances; Methodes d'analyse de la qualite de l'energie electrique. Application aux creux de tension et a la pollution harmonique

    Energy Technology Data Exchange (ETDEWEB)

    Vanya, Ignatova

    2006-10-15

    The power quality concerns all the actors in the energy domains, that they are network administrators, suppliers, producers, or consumers of electricity. The research work presented in this PhD thesis is situated in the field of the power quality monitoring. Its objective is to introduce new techniques for analysis of power quality problems. There are different methods designed for the analysis of the power quality disturbances. This method reaches very good performances in the voltage dips analysis, as it allows segmenting, classifying and characterising these power quality disturbances. The periodic systems method allows the theoretical study of the generation and the propagation of harmonic disturbances in the network. Finally, the statistical matrix method has the objective to represent statistically electrical signals without loss of important information. (author)

  6. Increase in the number of distributed power generation installations in electricity distribution grids - Simulation in a 400 V low-voltage network; Zunahme der dezentralen Energieerzeugungsanlagen in elektrischen Verteilnetzen: Simulationen im 400 V Niederspannungsnetz des ewz

    Energy Technology Data Exchange (ETDEWEB)

    Hoeckel, M.; Luechinger, P.

    2003-07-01

    This is the sixth part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This fifth appendix to the main report presents and discusses the results of simulations made on the basis of the real-life 400 V low-voltage distribution network operated by the public utilities of the City of Zurich, Switzerland. This comprehensive appendix describes the simulation methods used and the basic characteristics of low-voltage networks and distributed generation facilities. The 6 simulation variants used are also described. The results of the simulations are presented in graphical form and provide profiles of voltage and current, active and reactive power and further mains characteristics for varying load conditions. Also, short-circuit simulations and harmonics analysis are discussed.

  7. Irreversibility in room temperature current–voltage characteristics of NiFe{sub 2}O{sub 4} nanoparticles: A signature of electrical memory effect

    Energy Technology Data Exchange (ETDEWEB)

    Dey, P., E-mail: pujaiitkgp2007@gmail.com [Department of Physics, Kazi Nazrul University, Asansol, W.B. 713340 (India); Debnath, Rajesh; Singh, Swati; Mandal, S.K. [Department of Physics, National Institute of Technology Agartala, Tripura 799046 (India); Roy, J.N. [Department of Physics, Kazi Nazrul University, Asansol, W.B. 713340 (India); Department of Physics, National Institute of Technology Agartala, Tripura 799046 (India)

    2017-01-01

    Room temperature I–V characteristics study, both in presence and absence of magnetic field (1800 Oe), has been performed on NiFe{sub 2}O{sub 4} nanoparticles, having different particle size (φ~14, 21 and 31 nm). Our experiments on these nanoparticles provide evidences for: (1) electrical irreversibility or hysteretic behaviour; (2) positive magnetoresistance and (3) magnetic field dependent electrical irreversibility or hysteresis in the sample. “Hysteretic” nature of I–V curve reveals the existence of electrical memory effect in the sample. Significantly, such hysteresis has been found to be tuned by magnetic field. In order to explain the observed electrical irreversibility, we have proposed a phenomenological model on the light of induced polarization in the sample. Both the positive magnetoresistance and the observed magnetic field dependence of electrical irreversibility have been explained through magnetostriction phenomenon. Interestingly, such effects are found to get reduced with increasing particle size. For NiFe{sub 2}O{sub 4} nanoparticles having φ=31 nm, we did not observe any irreversibility effect. This feature has been attributed to the enhanced grain surface effect that in turn gives rise to the residual polarization and hence electrical memory effect in NiFe{sub 2}O{sub 4} nanoparticles, having small nanoscopic particle size. - Highlights: • I-V characteristics study of NiFe{sub 2}O{sub 4} nanoparticles with varying particle sizes. • Experiments evident electrical hysteretic behaviour, i.e., electrical memory effect. • Magnetic field dependent electrical irreversibility is due to magnetostriction. • A phenomenological model has been proposed on the light of induced polarization. • Such electrical irreversibility decreases with increasing particle sizes.

  8. Irreversibility in room temperature current–voltage characteristics of NiFe_2O_4 nanoparticles: A signature of electrical memory effect

    International Nuclear Information System (INIS)

    Dey, P.; Debnath, Rajesh; Singh, Swati; Mandal, S.K.; Roy, J.N.

    2017-01-01

    Room temperature I–V characteristics study, both in presence and absence of magnetic field (1800 Oe), has been performed on NiFe_2O_4 nanoparticles, having different particle size (φ~14, 21 and 31 nm). Our experiments on these nanoparticles provide evidences for: (1) electrical irreversibility or hysteretic behaviour; (2) positive magnetoresistance and (3) magnetic field dependent electrical irreversibility or hysteresis in the sample. “Hysteretic” nature of I–V curve reveals the existence of electrical memory effect in the sample. Significantly, such hysteresis has been found to be tuned by magnetic field. In order to explain the observed electrical irreversibility, we have proposed a phenomenological model on the light of induced polarization in the sample. Both the positive magnetoresistance and the observed magnetic field dependence of electrical irreversibility have been explained through magnetostriction phenomenon. Interestingly, such effects are found to get reduced with increasing particle size. For NiFe_2O_4 nanoparticles having φ=31 nm, we did not observe any irreversibility effect. This feature has been attributed to the enhanced grain surface effect that in turn gives rise to the residual polarization and hence electrical memory effect in NiFe_2O_4 nanoparticles, having small nanoscopic particle size. - Highlights: • I-V characteristics study of NiFe_2O_4 nanoparticles with varying particle sizes. • Experiments evident electrical hysteretic behaviour, i.e., electrical memory effect. • Magnetic field dependent electrical irreversibility is due to magnetostriction. • A phenomenological model has been proposed on the light of induced polarization. • Such electrical irreversibility decreases with increasing particle sizes.

  9. Investigation of disorder and its effect on electrical transport in electrochemically doped polymer devices by current-voltage and impedance spectroscopy

    Science.gov (United States)

    Rahman Khan, Motiur; Anjaneyulu, P.; Koteswara Rao, K. S. R.; Menon, R.

    2017-03-01

    We report on the analysis of temperature-dependent current-voltage characteristics and impedance measurements of electrochemically doped poly(3-methylthiophene) devices at different doping levels. The extent of doping is carefully tailored such that only the bulk-limited transport mechanism prevails. A transition from exponentially distributed trap-limited transport to trap-free space-charge-limited current is observed in current-voltage conduction upon increasing the doping. The obtained trap densities (3.2  ×  1016 cm-3 and 8.6  ×  1015 cm-3) and trap energies (31.7 meV and 16.6 meV) for different devices signify the variation in disorder with doping, which is later supported by impedance measurements. Impedance-frequency data for various devices can not be explained using the parallel resistance-capacitance (RC) model in the equivalent circuit. However, this was established by incorporating a constant phase element Q (CPE) instead of the capacitance parameter. It should be emphasized that low doping devices in particular are best simulated with two CPE elements, while the data related to other devices are fitted well with a single CPE element. It is also observed from evaluated circuit parameters that the spatial inhomogeneity and disorder are the cause of variability in different samples, which has an excellent correlation with the temperature-dependent current-voltage characteristics.

  10. Investigation of disorder and its effect on electrical transport in electrochemically doped polymer devices by current–voltage and impedance spectroscopy

    International Nuclear Information System (INIS)

    Khan, Motiur Rahman; Koteswara Rao, K S R; Menon, R; Anjaneyulu, P

    2017-01-01

    We report on the analysis of temperature-dependent current–voltage characteristics and impedance measurements of electrochemically doped poly(3-methylthiophene) devices at different doping levels. The extent of doping is carefully tailored such that only the bulk-limited transport mechanism prevails. A transition from exponentially distributed trap-limited transport to trap-free space-charge-limited current is observed in current–voltage conduction upon increasing the doping. The obtained trap densities (3.2  ×  10 16 cm −3 and 8.6  ×  10 15 cm −3 ) and trap energies (31.7 meV and 16.6 meV) for different devices signify the variation in disorder with doping, which is later supported by impedance measurements. Impedance–frequency data for various devices can not be explained using the parallel resistance–capacitance ( RC ) model in the equivalent circuit. However, this was established by incorporating a constant phase element Q (CPE) instead of the capacitance parameter. It should be emphasized that low doping devices in particular are best simulated with two CPE elements, while the data related to other devices are fitted well with a single CPE element. It is also observed from evaluated circuit parameters that the spatial inhomogeneity and disorder are the cause of variability in different samples, which has an excellent correlation with the temperature-dependent current–voltage characteristics. (paper)

  11. Design and Control of a Dynamic Voltage Restorer

    DEFF Research Database (Denmark)

    Nielsen, John Godsk

    voltage until the energy storage is completely drained or the voltages have returned to normal voltage levels. The control of the HV-DVR is a combined feedforward and feedback control to have a fast response time and load independent voltages. The control is implemented in a rotating dq-reference frame...... electric consumers against voltage dips and surges in the medium and low voltage distribution grid. The thesis first gives an introduction to relevant power quality issues for a DVR and power electronic controllers for voltage dip mitigation. Thereafter the operation and the elements in a DVR are described...... of symmetrical and non-symmetrical voltage dips. In most cases the DVR is capable of restoring the load voltages within 2 ms. During the transition phases load voltage oscillations can be generated and during the return of the supply voltages short time over-voltages can be generated by the DVR. Both...

  12. Hybrid electric vehicle power management system

    Science.gov (United States)

    Bissontz, Jay E.

    2015-08-25

    Level voltage levels/states of charge are maintained among a plurality of high voltage DC electrical storage devices/traction battery packs that are arrayed in series to support operation of a hybrid electric vehicle drive train. Each high voltage DC electrical storage device supports a high voltage power bus, to which at least one controllable load is connected, and at least a first lower voltage level electrical distribution system. The rate of power transfer from the high voltage DC electrical storage devices to the at least first lower voltage electrical distribution system is controlled by DC-DC converters.

  13. Electric Vehicle Interaction at the Electrical Circuit Level

    Science.gov (United States)

    2018-01-01

    The objective of the Electric Vehicle Interaction at the Electrical Circuit Level project was to investigate electric vehicle (EV) charging as a means of mitigating transient over-voltages (TOVs) on the circuit level electric utility distribution gri...

  14. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  15. Integrating Multi-Domain Distributed Energy Systems with Electric Vehicle PQ Flexibility: Optimal Design and Operation Scheduling for Sustainable Low-Voltage Distribution Grids

    DEFF Research Database (Denmark)

    Morvaj, Boran; Knezovic, Katarina; Evins, Ralph

    2016-01-01

    on the grid operation, in addition to coordinated charging, is analysed. Results showed that when the system can be optimally designed, emissions decrease by 64% and additionally 32% with proactive EV integration, whereas EV reactive power control enables integration of larger EV amounts and provides...... in the stable operation. The model was applied to a real low-voltage Danish distribution grid where measurement data is available on hourly basis in order to determine EV flexibility impacts on carbon emissions, as well as the benefits of optimal DES design. The influence of EV reactive power control...

  16. Cardioprotective effect of hyperthyroidism on the stunned rat heart during ischaemia-reperfusion: energetics and role of mitochondria.

    Science.gov (United States)

    Ragone, María Inés; Bonazzola, Patricia; Colareda, Germán A; Consolini, Alicia E

    2015-06-01

    What is the central question of this study? Hyperthyroidism is a cardiac risk factor, but thyroid therapy is used on myocardial stunning. What is the consequence of hyperthyroidism for mitochondrial metabolism and Ca(2+) handling of the postischaemic stunned heart? What is the main finding and its importance? Hyperthyroidism reduced stunning and improved muscle economy of the postischaemic rat heart. The activities of the mitochondrial sodium-calcium exchanger and mitochondrial K(+) channel in hyperthyroid rat hearts were different from those in the euthyroid rat hearts. These findings contribute to the understanding of mitochondrial bioenergetics in pathology and support thyroid therapy in the stunning induced by ischaemia. Transient ischaemia and hyperthyroidism are cardiovascular risk factors. Nevertheless, 3,5,3'-triiodothyronine/thyroxine therapy has been used to revert myocardial stunning. We studied the influence of hyperthyroidism on the role played by mitochondria in myocardial stunning consequent to ischaemia-reperfusion. Rats were injected s.c. daily with 20 μg kg(-1) triiodothyronine for 15 days (HpT group). Isolated ventricles from either HpT or euthyroid (EuT) rats were perfused in a calorimeter, and left intraventricular pressure (in millimetres of mercury) and heat release (Ht; in milliwatts per gram) were measured. Stunning was evoked by 20 min of no-flow ischaemia and 45 min reperfusion. The HpT hearts developed higher postischaemic contractile recovery (PICR) and improved total muscle economy (P/Ht) with lower diastolic contracture (ΔLVEDP) than EuT hearts. Release of Ca(2+) from the sarcoplasmic reticulum during reperfusion with 10 mm caffeine in low-[Na(+) ] Krebs solution evoked a higher contracture in EuT than in HpT hearts. Blockade of the mitochondrial sodium-calcium exchanger with clonazepam increased ΔLVEDP and reduced P/Ht and PICR in HpT but not in EuT hearts. The clonazepam-induced dysfunction in HpT hearts was reduced by

  17. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  18. Effects of light on responses to low atmospheric pressure stunning in broilers.

    Science.gov (United States)

    Martin, J E; Christensen, K; Vizzier-Thaxton, Y; McKeegan, D E F

    2016-10-01

    Low atmospheric pressure stunning (LAPS) is a novel approach to poultry stunning involving the application of gradual decompression lasting 280 s according to a prescribed pressure curve. The aim of this study was to determine how behavioural, electroencephalogram (EEG) and electrocardiogram (ECG) responses to LAPS are influenced by illumination of the decompression chamber. A secondary aim was to examine responses to the decompression chamber without LAPS being applied, as such a "sham" control has been absent in previous studies. A two by two factorial design was employed, with LAPS/light, LAPS/dark, sham/light and sham/dark treatments (N = 20 per treatment). Broilers were exposed to each treatment in pairs, in each of which one bird was instrumented for recording EEG and ECG. Illumination was applied at 500 lx, and in sham treatments, birds were identically handled but remained undisturbed in the LAPS chamber without decompression for 280 s. Birds which underwent the sham treatment exhibited behaviours which were also observed in LAPS (e.g. sitting) while those exposed to LAPS exhibited hypoxia-related behaviours (e.g. ataxia, loss of posture). Behavioural latencies and durations were increased in the sham treatments, since the whole cycle time was available (in LAPS; birds were motionless by 186 s). Within the sham treatments, illumination increased active behaviour and darkness induced sleep, but slow-wave EEG was seen in both. The pattern of EEG response to LAPS (steep reduction in median frequency in the first 60 s and increased total power) was similar, irrespective of illumination, though birds in darkness had shorter latencies to loss of consciousness and isoelectric EEG. Cardiac responses to LAPS (pronounced bradycardia) closely matched those reported previously and were not affected by illumination. The effects of LAPS/sham treatment primarily reflected the presence/absence of hypoxia, while illumination affected activity/sleep levels in sham

  19. Electricity

    International Nuclear Information System (INIS)

    Tombs, F.

    1983-01-01

    The subject is discussed, with particular reference to the electricity industry in the United Kingdom, under the headings; importance and scope of the industry's work; future fuel supplies (estimated indigenous fossil fuels reserves); outlook for UK energy supplies; problems of future generating capacity and fuel mix (energy policy; construction programme; economics and pricing; contribution of nuclear power - thermal and fast reactors; problems of conversion of oil-burning to coal-burning plant). (U.K.)

  20. Effects of ambient temperature and water vapor on chamber pressure and oxygen level during low atmospheric pressure stunning of poultry.

    Science.gov (United States)

    Holloway, Paul H; Pritchard, David G

    2017-08-01

    The characteristics of the vacuum used in a low atmospheric pressure stunning system to stun (render unconscious) poultry prior to slaughter are described. A vacuum chamber is pumped by a wet screw compressor. The vacuum pressure is reduced from ambient atmospheric pressure to an absolute vacuum pressure of ∼250 Torr (∼33 kPa) in ∼67 sec with the vacuum gate valve fully open. At ∼250 Torr, the sliding gate valve is partially closed to reduce effective pumping speed, resulting in a slower rate of decreasing pressure. Ambient temperature affects air density and water vapor pressure and thereby oxygen levels and the time at the minimum total pressure of ∼160 Torr (∼21 kPa) is varied from ∼120 to ∼220 sec to ensure an effective stun within the 280 seconds of each cycle. The reduction in total pressure results in a gradual reduction of oxygen partial pressure that was measured by a solid-state electrochemical oxygen sensor. The reduced oxygen pressure leads to hypoxia, which is recognized as a humane method of stunning poultry. The system maintains an oxygen concentration of air always reduces the oxygen concentrations to a value lower than in dry air. The partial pressure of water and oxygen were found to depend on the pump down parameters due to the formation of fog in the chamber and desorption of water from the birds and the walls of the vacuum chamber. © The Author 2017. Published by Oxford University Press on behalf of Poultry Science Association.

  1. Voltage regulating circuit

    NARCIS (Netherlands)

    2005-01-01

    A voltage regulating circuit comprising a rectifier (2) for receiving an AC voltage (Vmains) and for generating a rectified AC voltage (vrec), and a capacitor (3) connected in parallel with said rectified AC voltage for providing a DC voltage (VDC) over a load (5), characterized by a unidirectional

  2. Changes in the somatosensory evoked potentials and spontaneous electroencephalogram of hens during stunning in argon-induced anoxia.

    Science.gov (United States)

    Raj, A B; Gregory, N G; Wotton, S B

    1991-01-01

    This study examined the time to loss of consciousness in hens during stunning in argon-induced anoxia. Somatosensory evoked potentials (SEPs) and the spontaneous electroencephalogram (EEG) were recorded in 12 culled hens prior to and during stunning in less than 2% oxygen (air displaced by argon). An additional 20 hens were stunned with a similar concentration of oxygen and the time to loss of posture, eye closure, and the onset and duration of clonic and tonic convulsions were recorded. A further 10 hens were immersed in less than 2% oxygen for 15-17 s and their response to comb pinching was tested as soon as they had been transferred to atmospheric air. It is concluded that the birds had not lost the primary response in their SEPs by the time they started convulsing, but the reduction in the amplitude of the SEPs, changes in their spontaneous EEG and a negative response to comb pinch before the start of the convulsions indicated that the birds were unconscious when they convulsed.

  3. Efficiency of low versus high airline pressure in stunning cattle with a pneumatically powered penetrating captive bolt gun.

    Science.gov (United States)

    Oliveira, Steffan Edward Octávio; Gregory, Neville George; Dalla Costa, Filipe Antonio; Gibson, Troy John; Paranhos da Costa, Mateus José Rodrigues

    2017-08-01

    The efficiency of stunning cattle was assessed in 443 animals (304 pure Zebu and 139 crossbred cattle), being mainly mature bulls and cows. Cattle were stunned using a Jarvis pneumatically powered penetrating captive bolt gun operating with low (160-175psi, N=82) and high (190psi, N=363) airline pressure, which was within the manufactures specifications. Signs of brain function and the position of the shots on the heads were recorded after stunning. Velocity of the captive bolt and its physical parameters were calculated. Cattle shot with low pressures showed more rhythmic respiration (27 vs. 8%, P<0.001), less tongue protrusion (4 vs. 12%, P=0.03) and less masseter relaxation (22 vs. 48%, P<0.001). There was an increased frequency of shots in the ideal position when cattle were shot with the low compared to high airline pressures (15.3 vs. 3.1%). Bolt velocity and its physical parameters were significantly (P<0.01) higher when using high pressure. Airline pressures below 190psi are inappropriate when shooting adult Zebu beef cattle with pneumatically powered penetrating captive bolt guns. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Analysis of dynamic behavior of the back-to-back High Voltage Direct Current link model as part of electrical power system

    Directory of Open Access Journals (Sweden)

    Rudnik Vladimir

    2017-01-01

    Full Text Available One of the main directions of the development of electric power systems is the introduction of technologies based on high-power semiconductor switches, such as FACTS devices and HVDC technologies. These systems effectively solve a number of urgent tasks of EPS, connected with asynchronous connection of EPS, transmission of electricity, improve local and systemic flexibility and reliability of EPS, increasing the capacity of network elements that contains a “weak” connection. However, the implementation and operation of mentioned technologies in the EPS determines the need for a wide range of analysis and research that can only be done with the help of mathematical modeling.

  5. Electric shocks are ineffective in treatment of lethal effects of rattlesnake envenomation in mice.

    Science.gov (United States)

    Johnson, E K; Kardong, K V; Mackessy, S P

    1987-01-01

    Electrical shocks, even crudely delivered from 'stun guns' and gasoline engine spark plugs, have been reported to be effective in the treatment of snake bite. We thus applied similar electric shocks to mice artificially injected with reconstituted rattlesnake venom at various LD50 multiples. Those envenomated mice treated with electric shock survived no better than the controls. We thus found no evidence that electric shocks crudely administered had any life saving effect in mice.

  6. Electrical instability of a-Si:H/SiN thin film transistors : a study at room temperature and low voltage stress

    NARCIS (Netherlands)

    Merticaru, A.R.

    2004-01-01

    The thesis shows the results of four years of research into the electrical stability of a-Si:H/SiN TFTs. Various methods of investigation of a-Si:H/SiN TFTs have been carried out in this thesis towards understanding the causes of degradation that shortens the transistor lifetime and narrows the

  7. Cooling of electrically insulated high voltage electrodes down to 30 mK Kühlung von elektrisch isolierten Hochspannungselektroden bis 30 mK

    CERN Document Server

    Eisel, Thomas; Bremer, J

    2011-01-01

    The Antimatter Experiment: Gravity, Interferometry, Spectroscopy (AEGIS) at the European Organization for Nuclear Research (CERN) is an experiment investigating the influence of earth’s gravitational force upon antimatter. To perform precise measurements the antimatter needs to be cooled to a temperature of 100 mK. This will be done in a Penning trap, formed by several electrodes, which are charged with several kV and have to be individually electrically insulated. The trap is thermally linked to a mixing chamber of a 3He-4He dilution refrigerator. Two link designs are examined, the Rod design and the Sandwich design. The Rod design electrically connects a single electrode with a heat exchanger, immersed in the helium of the mixing chamber, by a copper pin. An alumina ring and the helium electrically insulate the Rod design. The Sandwich uses an electrically insulating sapphire plate sandwiched between the electrode and the mixing chamber. Indium layers on the sapphire plate are applied to improve the ther...

  8. Electric Co'Co' bi-voltage locomotive class EG 3100 of DSB; Co'Co'-Zweifrequenzlokomotive EG 3100 fuer Danske Statsbaner

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, B.O. [DSB Materiel Technik, Copenhagen (Denmark); Joergensen, O.A. [Siemens AG, Erlangen (Germany). Abt. VT 62; Proell, J. [Siemens AG, Muenchen (Germany). Abt. VT 68

    2000-12-01

    DSB has purchased a series of heavy electric locomotives for hauling transit freight trains between Central Europe and Scandinavia. Demands, basic features and technical components are described in detail. (orig.) [German] Fuer den Transitgueterverkehr zwischen Mitteleuropa und Skandinavien hat Danske Statsbaner eine Serie schwerer elektrischer Lokomotiven beschafft. Die Anforderungen, das Grundkonzept und die technischen Komponenten werden ausfuehrlich beschrieben. (orig.)

  9. Electric Co'Co' bi-voltage locomotive class EG 3100 of DSB; Co'Co'-Zweifrequenzlokomotive EG 3100 fuer Danske Statsbaner

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, B.O. [DSB Materiel Technik, Copenhagen (Denmark); Joergensen, O.A. [Siemens AG, Erlangen (Germany). Abt. VT 62; Proell, G. [Siemens AG, Muenchen (Germany). Abt. VT 68

    2001-07-01

    DSB has purchased a series of heavy electric locomotives for hauling transit freight trains between Central Europe and Scandinavia. Demands, basic features and technical components are described in detail. (orig.) [German] Fuer den Transitgueterverkehr zwischen Mitteleuropa und Skandinavien hat Danske Statsbaner eine Serie schwerer elektrischer Lokomotiven beschafft. Die Anforderungen, das Grundkonzept und die technischen Komponenten werden ausfuehrlich beschrieben. (orig.)

  10. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    Science.gov (United States)

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  11. Stunning method effect on the most important parameters which influence sacrifice and quality of pork

    Directory of Open Access Journals (Sweden)

    José Guadalupe Gamboa-Alvarado

    2011-12-01

    Full Text Available The effect of captive bolt pistol (PP and knocked down by hammer (NM on sensibility and pork quality was evaluated employing 28 commercial porks considering as co-variables the ante mortem rest (REP, and environmental moisture (HUM and temperature (TEMP during sacrifice. PSE carcasses presence was higher (P0.05 was observed in the pH and TEMP at 45 min (pH45 and T45, nor at 24 h (pH24 and T24 post mortem in luminosity (L*, yellowness (b* and drip loss (PG, probably because the muscles were already affected by the ante mortem handling. The pH24 showed a negative relationship (P<0.05 with REP and, when REP was superior to 43h, pH24 were characteristics of PSE carcasses. The increase in HUM and REP provoked higher (P<0.01 T24, where carcass cooling required more attention. The knocked down by hammer (NM provoked a higher (P<0.01 redness and CRA by the accumulate stress during ante mortem handling and stunning.

  12. A mechanochemical approach to get stunningly uniform particles of magnesium-aluminum-layered double hydroxides

    Science.gov (United States)

    Zhang, Xiaoqing; Qi, Fenglin; Li, Shuping; Wei, Shaohua; Zhou, Jiahong

    2012-10-01

    A mechanochemical approach is developed in preparing a series of magnesium-aluminum-layered double hydroxides (Mg-Al-LDHs). This approach includes a mechanochemical process which involved manual grinding of solid salts in an agate mortar and afterwards peptization process. In order to verify the LDHs structure synthesized in the grinding process, X-ray diffraction (XRD) patterns, transmission electron microscopy (TEM) photos and thermogravimetry/differential scanning calorimetry (TG-DSC) property of the product without peptization were characterized and the results show that amorphous particles with low crystallinity and poor thermal stability are obtained, and the effect of peptization is to improve the properties, more accurately, regular particles with high crystallinity and good thermal stability can be gained after peptization. Furthermore, the fundamental experimental parameters including grinding time, the molar ratio of Mg to Al element (defined as R value) and the water content were systematically examined in order to control the size and morphologies of LDHs particles, regular hexagonal particles or the spherical nanostructures can be efficiently obtained and the particle sizes were controlled in the range of 52-130 nm by carefully adjusting these parameters. At last, stunningly uniform Mg-Al-LDHs particles can be synthesized under proper R values, suitable grinding time and high degree of supersaturation.

  13. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator; Etude de dispositifs de protection contre les effets des decharges electriques au sein d`un generateur de tres haute tension: l`accelerateur Vivitron

    Energy Technology Data Exchange (ETDEWEB)

    Nolot, E

    1996-10-31

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF{sub 6}. This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF{sub 6}. In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author). 122 refs.

  14. Control and operation of power sources in a medium-voltage direct-current microgrid for an electric vehicle fast charging station with a photovoltaic and a battery energy storage system

    International Nuclear Information System (INIS)

    García-Triviño, Pablo; Torreglosa, Juan P.; Fernández-Ramírez, Luis M.; Jurado, Francisco

    2016-01-01

    Although electric vehicles (EVs) are experiencing a considerable upsurge, the technology associated with them is still under development. This study focused on the control and operation of a medium-voltage direct-current (MVDC) microgrid with an innovative decentralized control system, which was used as a fast charging station (FCS) for EVs. The FCS was composed of a photovoltaic (PV) system, a Li-ion battery energy storage system (BESS), two 48 kW fast charging units for EVs, and a connection to the local grid. With this configuration and thanks to its decentralized control, the FCS was able to work as a stand-alone system most of the time though with occasional grid support. This paper presents a new decentralized energy management system (EMS) with two options to control the power sources of the FCS. The choice of the power source depends on the MVDC bus voltage, the state-of-charge (SOC) of the BESS, and the control option of the EMS. This control was tested by simulating the FCS, when connected to several EVs and under different sun irradiance conditions. Simulation results showed that the FCS operated smoothly and effectively, which confirms the feasibility of using this technology in EVs. - Highlights: • This paper studies a MVDC microgrid for fast charging station of EV. • It is composed of a PV system, a BESS, two EV charging stations and a grid connection. • A decentralized control scheme is applied to control the power sources. • The MVDC bus voltage is the key parameter for controlling the system. • The results demonstrate the feasibility of the system and control under study.

  15. {sup 99m}Tc-glucarate kinetics differentiate normal, stunned, hibernating, and nonviable myocardium in a perfused rat heart model

    Energy Technology Data Exchange (ETDEWEB)

    Okada, David R. [University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Liu, Zhonglin [University of Arizona School of Medicine, Tucson, AZ (United States); Johnson, Gerald; Okada, Robert D. [University of Oklahoma Health Sciences Center, Oklahoma, OK (United States); University of Tulsa, Tulsa, OK (United States); Beju, Delia [Oklahoma State University School of Medicine, Tulsa, OK (United States); Khaw, Ban An [Northeastern University, Boston, MA (United States)

    2010-10-15

    {sup 99m}Tc-glucarate is an infarct-avid imaging agent. However, patients may have mixtures of normal, irreversibly injured, stunned, and hibernating myocardium. The purposes were to determine {sup 99m}Tc-glucarate uptake and clearance kinetics in these four conditions, and its ability to determine the extent of injury. Twenty-two perfused rat hearts were studied: controls (n = 5), stunned (n = 5; 20-min no-flow followed by 5-min reflow), hibernating (n = 6; 120-min low flow at 4 ml/min), and ischemic-reperfused (n = 6; 120-min no-flow followed by reflow). {sup 99m}Tc-glucarate was then infused. Tracer activity was monitored using a NaI scintillation detector and a multichannel analyzer. Creatine kinase, electron microscopy, and triphenyltetrazolium chloride determined viability. {sup 99m}Tc-glucarate 10-min myocardial uptake was significantly greater in ischemic-reperfused (2.50 {+-} 0.09) (cpm, SEM) than in control (1.74 {+-} 0.07), stunned (1.68 {+-} 0.11), and hibernating (1.59 {+-} 0.11) (p < 0.05). Tracer retention curves for ischemic-reperfused were elevated at all time points as compared with the other groups. {sup 99m}Tc-glucarate 60-min myocardial uptake was significantly greater in ischemic-reperfused (7.60 {+-} 0.63) than in control (1.98 {+-} 0.15), stunned (1.79 {+-} 0.08), and hibernating (2.33 {+-} 0.15) (p < 0.05). The 60-min well-counted tracer activity ratio of ischemic-reperfused to control was 9:1 and corroborated the NaI detector results. Creatine kinase, triphenyltetrazolium chloride, and electron microscopy all demonstrated significantly greater injury in ischemic-reperfused compared to the other groups. An excellent correlation was observed between viability markers and tracer activity (r = 0.99 triphenyltetrazolium chloride; r = 0.90 creatine kinase). {sup 99m}Tc-glucarate activity continually and progressively increased in irreversibly injured myocardium. {sup 99m}Tc-glucarate uptake was strongly correlated with myocardial necrosis as

  16. Electron–Cyclotron Laser Using Free-Electron Two-Quantum Stark Radiation in a Strong Uniform Axial Magnetic Field and an Alternating Axial Electric Field in a Voltage-Supplied Pill-Box Cavity

    International Nuclear Information System (INIS)

    Kim, S. H.

    2016-01-01

    We consider the radiation from the beam electrons traveling in a strong uniform axial magnetic field and an axial alternating electric field of wavelength λ_w generated by a voltage-supplied pill-box cavity. The beam electrons emit genuine laser radiation that propagates only in the axial direction through free-electron two-quantum Stark radiation. We find that laser radiation takes place only at the expense of the axial kinetic energy when λ_w ≪ c/(ω_c/γ), where ω_c/γ is the relativistic electron–cyclotron frequency. We formulate the laser power based on quantum-wiggler electrodynamics, and envision a laser of length 10 m with estimated power 0.1 GW/(kA) in the 10"−"4 cm wavelength range. (paper)

  17. High voltage switches having one or more floating conductor layers

    Science.gov (United States)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    2015-11-24

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of one or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.

  18. Design of shielded voltage divider for impulse voltage measurement

    International Nuclear Information System (INIS)

    Kato, Shohei; Kouno, Teruya; Maruyama, Yoshio; Kikuchi, Koji.

    1976-01-01

    The dividers used for the study of the insulation and electric discharge phenomena in high voltage equipments have the problems of the change of response characteristics owing to adjacent bodies and of induced noise. To improve the characteristics, the enclosed type divider shielded with metal has been investigated, and the divider of excellent response has been obtained by adopting the frequency-separating divider system, which is divided into two parts, resistance divider (lower frequency region) and capacitance divider (higher frequency region), for avoiding to degrade the response. Theoretical analysis was carried out in the cases that residual inductance can be neglected or can not be neglected in the small capacitance divider, and that the connecting wires are added. Next, the structure of the divider and the design of the electric field for the divider manufactured on the basis of the theory are described. The response characteristics were measured. The results show that 1 MV impulse voltage can be measured within the response time of 10 ns. Though this divider aims at the impulse voltage, the duration time of which is about that of standard lightning impulse, in view of the heat capacity because of the input resistance of 10.5 kΩ, it is expected that the divider can be applied to the voltage of longer duration time by increasing the input resistance in future. (Wakatsuki, Y.)

  19. High voltage isolation transformer

    Science.gov (United States)

    Clatterbuck, C. H.; Ruitberg, A. P. (Inventor)

    1985-01-01

    A high voltage isolation transformer is provided with primary and secondary coils separated by discrete electrostatic shields from the surfaces of insulating spools on which the coils are wound. The electrostatic shields are formed by coatings of a compound with a low electrical conductivity which completely encase the coils and adhere to the surfaces of the insulating spools adjacent to the coils. Coatings of the compound also line axial bores of the spools, thereby forming electrostatic shields separating the spools from legs of a ferromagnetic core extending through the bores. The transformer is able to isolate a high constant potential applied to one of its coils, without the occurrence of sparking or corona, by coupling the coatings, lining the axial bores to the ferromagnetic core and by coupling one terminal of each coil to the respective coating encasing the coil.

  20. Compact, Lightweight, High Voltage Propellant Isolators, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  1. Animal welfare concerns during the use of the water bath for stunning broilers, hens and ducks.

    NARCIS (Netherlands)

    Hindle, V.A.; Lambooij, B.; Reimert, H.G.M.; Workel, L.D.; Gerritzen, M.A.

    2010-01-01

    European legislation demands that slaughter animals, including poultry, be rendered immediately unconscious and insensible until death occurs through blood loss at slaughter. This study addressed requirements for stunner settings (i.e., voltage, wave oscillation frequency) and response parameters

  2. High frequency relay protection channels on super high voltage lines

    Energy Technology Data Exchange (ETDEWEB)

    Mikutskii, G V

    1964-08-01

    General aspects of high voltage transmission line design are discussed. The relationships between line voltage and length and line dimensions and power losses are explained. Electrical interference in the line is classified under three headings: interference under normal operating conditions, interference due to insulation faults, and interference due to variations in operating conditions of the high-voltage network.

  3. Voltage control of ferromagnetic resonance

    Directory of Open Access Journals (Sweden)

    Ziyao Zhou

    2016-06-01

    Full Text Available Voltage control of magnetism in multiferroics, where the ferromagnetism and ferroelectricity are simultaneously exhibiting, is of great importance to achieve compact, fast and energy efficient voltage controllable magnetic/microwave devices. Particularly, these devices are widely used in radar, aircraft, cell phones and satellites, where volume, response time and energy consumption is critical. Researchers realized electric field tuning of magnetic properties like magnetization, magnetic anisotropy and permeability in varied multiferroic heterostructures such as bulk, thin films and nanostructure by different magnetoelectric (ME coupling mechanism: strain/stress, interfacial charge, spin–electromagnetic (EM coupling and exchange coupling, etc. In this review, we focus on voltage control of ferromagnetic resonance (FMR in multiferroics. ME coupling-induced FMR change is critical in microwave devices, where the electric field tuning of magnetic effective anisotropic field determines the tunability of the performance of microwave devices. Experimentally, FMR measurement technique is also an important method to determine the small effective magnetic field change in small amount of magnetic material precisely due to its high sensitivity and to reveal the deep science of multiferroics, especially, voltage control of magnetism in novel mechanisms like interfacial charge, spin–EM coupling and exchange coupling.

  4. With the 42 V voltage, the automotive industry enters the all-electrical revolution; Avec le 42V, l'automobile aborde la revolution du tout-electrique

    Energy Technology Data Exchange (ETDEWEB)

    Landragin, J.P.

    2003-06-01

    The imminent change of the power voltage from 12 to 42 V will revolutionize the automotive industry world. Initially motivated by comfort reasons (space heating and air conditioning accessories), this evolution will have major impacts on the overall architecture of the vehicle, from the engine to the control parts (electric power steering, water and oil pumps, electromagnetic breaking, electrical suspension control, electromagnetic valve operation, air-conditioning compressor, heating of the passenger space, windscreen deicing, preheating of the catalytic converter etc..). The conversion to 42 V will require efficient and reliable power electronic systems (high frequency switching circuits, MOSFET, IGBT) which represent a real challenge for car makers with certainly a transition period during which vehicles will have two batteries: a 12 V one and a 36 V one. Moreover, the proliferation of electronic equipments with different powers and frequencies will lead to complex electromagnetic environments. The entirely powered-controlled vehicle concept ('X-by-wire' technology) is progressively making its way. It will require a perfectly safe and fault tolerant communication system (time-triggered protocol) for the automatic control of the different actuators. (J.S.)

  5. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  6. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...

  7. Basic Electricity. Part 3.

    Science.gov (United States)

    Kilmer, Donald C.

    Third (part 3) in a set of four guides designed for the student interested in a vocation in electrical work, this guide includes four units: Unit VI--Ohm's Law, covering six lessons (voltage, current-flow and resistance, the Ohm's Law formula, formula for finding voltage, formula for finding resistance); Unit VII--Voltages, covering five lessons…

  8. Carbon monoxide stunning of Atlantic salmon (Salmo salar L.) modifies rigor mortis and sensory traits as revealed by NIRS and other instruments.

    Science.gov (United States)

    Concollato, Anna; Parisi, Giuliana; Masoero, Giorgio; Romvàri, Robert; Olsen, Rolf-Erik; Dalle Zotte, Antonella

    2016-08-01

    Methods of stunning used in salmon slaughter are still the subject of research. Fish quality can be influenced by pre-, ante- and post-mortem conditions, including handling before slaughter, slaughter methods and storage conditions. Carbon monoxide (CO) is known to improve colour stability in red muscle and to reduce microbial growth and lipid oxidation in live fish exposed to CO. Quality differences in Atlantic salmon, Salmo salar L., stunned by CO or percussion, were evaluated and compared by different techniques [near infrared reflectance spectroscopy (NIRS), electronic nose (EN), electronic tongue (ET)] and sensory analysis. Thawed samples, freeze-dried preparates and NIRS devices proved to be the most efficient combinations for discriminating the treatments applied to salmon, i.e. first the stunning methods adopted, then the back-prediction of the maximum time to reach rigor mortis and finally to correlate some sensory attributes. A trained panel found significant differences between control and CO-stunned salmon: reduced tactile crumbliness, reduced odour and aroma intensities, and reduced tenderness of CO-treated fillets. CO stunning reduced radiation absorbance in spectra of thawed and freeze-dried fillets, but not fillet samples stored in ethanol, where it may have interacted with myoglobin and myosin. The good results in a rapid discrimination of thawed samples detected by NIRS suggest suitable applications in the fish industry. CO treatment could mitigate sensory perception, but consumer tests are needed to confirm our findings. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  9. Controlled atmosphere stunning of broiler chickens. I. Effects on behaviour, physiology and meat quality in a pilot scale system at a processing plant.

    Science.gov (United States)

    Abeyesinghe, S M; McKeegan, D E F; McLeman, M A; Lowe, J C; Demmers, T G M; White, R P; Kranen, R W; van Bemmel, H; Lankhaar, J A C; Wathes, C M

    2007-08-01

    1. The effects of controlled atmosphere stunning on the behaviour, physiology and carcase and meat quality of broiler chickens were studied experimentally in a pilot scale plant. 2. Gas mixtures tested were: single phase anoxic mixture (90% Ar in air, posture occurred soonest with hypercapnic anoxia with the earliest and most twitching and wing flapping in individuals and earliest leg paddling. Biphasic birds were most alert, exhibited most respiratory disruption and mandibulation, and had the latest loss of posture and fewest, but longest bouts of wing flapping and least leg paddling and twitching. 4. Significant and sudden bradycardia and arrhythmia were evident with all gas mixtures and were not related solely to anoxia or hypercapnia. Birds stunned by Ar anoxia showed a slightly more gradual decline from baseline rates, compared with hypercapnic mixtures. 5. Few differences were found between gas mixes in terms of carcase and meat quality. Initial bleeding rate was slowest in biphasic-stunned birds, but total blood loss was not affected. Acceleration of post-mortem metabolism in anoxic-stunned birds was not sufficient to allow de-boning within 5 h without the risk of tough meat. 6. On welfare grounds and taking into account other laboratory and field studies, a biphasic method (using consecutive phases of anaesthesia and euthanasia) of controlled atmosphere stunning of broilers is potentially more humane than anoxic or hypercapnic anoxic methods using argon or nitrogen.

  10. Fuel Cell/Electrochemical Cell Voltage Monitor

    Science.gov (United States)

    Vasquez, Arturo

    2012-01-01

    A concept has been developed for a new fuel cell individual-cell-voltage monitor that can be directly connected to a multi-cell fuel cell stack for direct substack power provisioning. It can also provide voltage isolation for applications in high-voltage fuel cell stacks. The technology consists of basic modules, each with an 8- to 16-cell input electrical measurement connection port. For each basic module, a power input connection would be provided for direct connection to a sub-stack of fuel cells in series within the larger stack. This power connection would allow for module power to be available in the range of 9-15 volts DC. The relatively low voltage differences that the module would encounter from the input electrical measurement connection port, coupled with the fact that the module's operating power is supplied by the same substack voltage input (and so will be at similar voltage), provides for elimination of high-commonmode voltage issues within each module. Within each module, there would be options for analog-to-digital conversion and data transfer schemes. Each module would also include a data-output/communication port. Each of these ports would be required to be either non-electrical (e.g., optically isolated) or electrically isolated. This is necessary to account for the fact that the plurality of modules attached to the stack will normally be at a range of voltages approaching the full range of the fuel cell stack operating voltages. A communications/ data bus could interface with the several basic modules. Options have been identified for command inputs from the spacecraft vehicle controller, and for output-status/data feeds to the vehicle.

  11. Flow-driven voltage generation in carbon nanotubes

    Indian Academy of Sciences (India)

    The flow of various liquids and gases over single-walled carbon nanotube bundles induces an electrical signal (voltage/current) in the sample along the direction of the flow. The electrical response generated by the flow of liquids is found to be logarithmic in the flow speed over a wide range. In contrast, voltage generated ...

  12. A Quantification of the Energy Savings by Conservation Voltage Reduction

    NARCIS (Netherlands)

    Ellens, W.; Berry, A.; West, S.

    2013-01-01

    The introduction of `Smart grid' technologies in the electricity supply industry has attracted new attention to Conservation Voltage Reduction (CVR). CVR is a method that aims to save energy by reducing the voltage level of the electrical distribution network. However, not all devices consume less

  13. A prospective study analyzing the application of radiofrequency energy and high-voltage, ultrashort pulse duration electrical fields on the quantitative reduction of adipose tissue.

    Science.gov (United States)

    Duncan, Diane Irvine; Kim, Theresa H M; Temaat, Robbin

    2016-10-01

    Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to - 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action.

  14. Overvoltage in low voltage systems due to mean voltage manoeuvres; Sobretensoes em sistemas de BT devidas a manobras na media tensao

    Energy Technology Data Exchange (ETDEWEB)

    Pazos, Francisco Jose; Amantegui, Javier; Ferrandis, Francisco; Barona, Amaya [Iberdrola, Madrid (Spain)

    2008-04-15

    The voltage interruption due to mean voltage maneuverers normal operation produces a transient type which is converted in a overvoltage on the low voltage circuit. Nevertheless to be considered a normal phenomena those over voltages have been pointed out as cause for damage in electric home appliances. What are the reasons? Inadequate protection or lack of immunity of the equipment?.

  15. Control voltage of the generator of auto-excited induction for applications on micro/mini generation o electric power; Control de voltaje del generador de induccion auto-excitado para aplicaciones de micro/mini generacion de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Torres Montalvo, Emmanuel

    2006-09-15

    Although only one part of the mini/micro hydraulic power has been exploited in our country, this type of electric energy generation can be considered as a visible way of electricity generation, mainly related to the ecological, economical and social aspects. The impact that these power plants can have in the regions in which they are installed is always positive: cost energy cost reduction, economical spills and mainly a social welfare. The electric energy is one of the pillars for the economical development of a country and provides a better life quality. Nowadays the research and the technology oriented to the operation and control of the micro/mini power plants has awaken the interest of many researchers in several countries of the world as China, India, Canada, and USA to mention some of them. The induction generator plays a crucial role in the uses of these technologies. The work of Basset and Potter in 1935 is the angular stone over the possibility of generating energy making use of the induction machine and a capacitors bank connected to the machine terminals. This configuration is known as induction auto-excited generator (GIAE). Several investigations have been realized that deal about the functioning principle and the dynamic behavior a GIAE, which can supply electric power in remote isolated regions. In the existing literature have been proposed control strategies to offer voltage regulations and/or frequency into the acceptable range. Some of these control strategies present problems such a demand of a reactive power, harmonics injections in the system, the control circuits are complicated, expensive and voluminous and prone to fail. This paper realizes an analysis of the necessary and sufficient conditions so that an induction machine can operate as GIAE. The corresponding curves are presented for each studied case. The dynamic behavior of the voltage and the frequency generated by the GIAE are studied in detail, which is a contribution to the existing

  16. Maximum permissible voltage of YBCO coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Wen, J.; Lin, B.; Sheng, J.; Xu, J.; Jin, Z. [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Hong, Z., E-mail: zhiyong.hong@sjtu.edu.cn [Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China); Wang, D.; Zhou, H.; Shen, X.; Shen, C. [Qingpu Power Supply Company, State Grid Shanghai Municipal Electric Power Company, Shanghai (China)

    2014-06-15

    Highlights: • We examine three kinds of tapes’ maximum permissible voltage. • We examine the relationship between quenching duration and maximum permissible voltage. • Continuous I{sub c} degradations under repetitive quenching where tapes reaching maximum permissible voltage. • The relationship between maximum permissible voltage and resistance, temperature. - Abstract: Superconducting fault current limiter (SFCL) could reduce short circuit currents in electrical power system. One of the most important thing in developing SFCL is to find out the maximum permissible voltage of each limiting element. The maximum permissible voltage is defined as the maximum voltage per unit length at which the YBCO coated conductors (CC) do not suffer from critical current (I{sub c}) degradation or burnout. In this research, the time of quenching process is changed and voltage is raised until the I{sub c} degradation or burnout happens. YBCO coated conductors test in the experiment are from American superconductor (AMSC) and Shanghai Jiao Tong University (SJTU). Along with the quenching duration increasing, the maximum permissible voltage of CC decreases. When quenching duration is 100 ms, the maximum permissible of SJTU CC, 12 mm AMSC CC and 4 mm AMSC CC are 0.72 V/cm, 0.52 V/cm and 1.2 V/cm respectively. Based on the results of samples, the whole length of CCs used in the design of a SFCL can be determined.

  17. Observability of Low Voltage grids

    DEFF Research Database (Denmark)

    Martin-Loeches, Ruben Sánchez; Iov, Florin; Kemal, Mohammed Seifu

    2017-01-01

    Low Voltage (LV) distribution power grids are experiencing a transformation from a passive to a more active role due to the increasing penetration of distributed generation, heat pumps and electrical vehicles. The first step towards a smarter operation of LV electrical systems is to provide grid ...... an updated state of the art on DSSE-AMI based, adaptive data collection techniques and database management system types. Moreover, the ongoing Danish RemoteGRID project is presented as a realistic case study.......Low Voltage (LV) distribution power grids are experiencing a transformation from a passive to a more active role due to the increasing penetration of distributed generation, heat pumps and electrical vehicles. The first step towards a smarter operation of LV electrical systems is to provide grid....... It becomes unrealistic to provide near real time full observability of the LV grid by applying Distribution System State Estimation (DSSE) utilizing the classical data collection and storage/preprocessing techniques. This paper investigates up-todate the observability problem in LV grids by providing...

  18. Voltage regulator for generator

    Energy Technology Data Exchange (ETDEWEB)

    Naoi, K

    1989-01-17

    It is an object of this invention to provide a voltage regulator for a generator charging a battery, wherein even if the ambient temperature at the voltage regulator rises abnormally high, possible thermal breakage of the semiconductor elements constituting the voltage regulator can be avoided. A feature of this invention is that the semiconductor elements can be protected from thermal breakage, even at an abnormal ambient temperature rise at the voltage regulator for the battery charging generator, by controlling a maximum conduction ratio of a power transistor in the voltage regulator in accordance with the temperature at the voltage regulator. This is achieved through a switching device connected in series to the field coil of the generator and adapted to be controlled in accordance with an output voltage of the generator and the ambient temperature at the voltage regulator. 6 figs.

  19. Dual voltage power supply with 48 volt

    Energy Technology Data Exchange (ETDEWEB)

    Froeschl, Joachim; Proebstle, Hartmut; Sirch, Ottmar [BMW Group, Muenchen (Germany)

    2012-11-01

    Automotive electrics/electronics have just reached a period of tremendous change. High voltage systems for Hybrid, Plug-In Hybrid or Battery Electric Vehicles with high power electric motors, high energy accumulators and electric climate compressors will be introduced in order to achieve the challenging targets for CO{sub 2} emissions and energy efficiency and to anticipate the mobility of the future. Additionally, innovations and the continuous increase of functionality for comfort, safety, driver assistance and infotainment systems require more and more electrical power of the vehicle power supply at all. On the one hand side electrified vehicles will certainly achieve a significant market share, on the other hand side they will increase the pressure to conventional vehicles with combustion engines for fuel consumption and CO{sub 2} emissions. These vehicles will be enabled to keep their competitiveness by new functions and the optimization of their electric systems. A dual voltage power supply with 48 Volt and 12 Volt will be one of the key technologies to realize these requirements. The power capability of the existing 12 Volt power supply has reached its limits. Further potentials can only be admitted by the introduction of 48 Volt. For this reason the car manufacturers Audi, BMW, Daimler, Porsche and Volkswagen started very early on this item and developed a common specification of the new voltage range. Now, it is necessary to identify the probable systems at this voltage range and to start the developments. (orig.)

  20. Analysis of NSTX TF Joint Voltage Measurements

    International Nuclear Information System (INIS)

    Woolley R

    2005-01-01

    This report presents findings of analyses of recorded current and voltage data associated with 72 electrical joints operating at high current and high mechanical stress. The analysis goal was to characterize the mechanical behavior of each joint and thus evaluate its mechanical supports. The joints are part of the toroidal field (TF) magnet system of the National Spherical Torus Experiment (NSTX) pulsed plasma device operating at the Princeton Plasma Physics Laboratory (PPPL). Since there is not sufficient space near the joints for much traditional mechanical instrumentation, small voltage probes were installed on each joint and their voltage monitoring waveforms have been recorded on sampling digitizers during each NSTX ''shot''

  1. Experimental validation of prototype high voltage bushing

    Science.gov (United States)

    Shah, Sejal; Tyagi, H.; Sharma, D.; Parmar, D.; M. N., Vishnudev; Joshi, K.; Patel, K.; Yadav, A.; Patel, R.; Bandyopadhyay, M.; Rotti, C.; Chakraborty, A.

    2017-08-01

    Prototype High voltage bushing (PHVB) is a scaled down configuration of DNB High Voltage Bushing (HVB) of ITER. It is designed for operation at 50 kV DC to ensure operational performance and thereby confirming the design configuration of DNB HVB. Two concentric insulators viz. Ceramic and Fiber reinforced polymer (FRP) rings are used as double layered vacuum boundary for 50 kV isolation between grounded and high voltage flanges. Stress shields are designed for smooth electric field distribution. During ceramic to Kovar brazing, spilling cannot be controlled which may lead to high localized electrostatic stress. To understand spilling phenomenon and precise stress calculation, quantitative analysis was performed using Scanning Electron Microscopy (SEM) of brazed sample and similar configuration modeled while performing the Finite Element (FE) analysis. FE analysis of PHVB is performed to find out electrical stresses on different areas of PHVB and are maintained similar to DNB HV Bushing. With this configuration, the experiment is performed considering ITER like vacuum and electrical parameters. Initial HV test is performed by temporary vacuum sealing arrangements using gaskets/O-rings at both ends in order to achieve desired vacuum and keep the system maintainable. During validation test, 50 kV voltage withstand is performed for one hour. Voltage withstand test for 60 kV DC (20% higher rated voltage) have also been performed without any breakdown. Successful operation of PHVB confirms the design of DNB HV Bushing. In this paper, configuration of PHVB with experimental validation data is presented.

  2. Electrical transport properties and laser-induced voltage effect in La{sub 0.8}Ca{sub 0.2}MnO{sub 3} epitaxial thin films

    Energy Technology Data Exchange (ETDEWEB)

    Theingi, Mya [Kunming University of Science and Technology, Faculty of Materials Science and Engineering, Kunming (China); University of Yangon, Department of Chemistry, Yangon (Myanmar); Ma, Ji; Zhang, Hui; Cui, Qi; Yi, Jianhong; Chen, Qingming [Kunming University of Science and Technology, Faculty of Materials Science and Engineering, Kunming (China)

    2014-03-15

    La{sub 0.8}Ca{sub 0.2}MnO{sub 3} (LCMO) thin films about 200 nm thickness were grown on untilted and tilted (5 , 10 and 15 ) LaAlO{sub 3} (100) single crystal substrates by pulsed laser deposition technique. Electrical properties of the epitaxial thin films were studied by conventional four-probe technique and the anisotropic thermoelectric properties of the films grown on the tilted substrates have been investigated by laser-induced voltage (LIV) measurements. X-ray diffraction analysis and atomic force microscopy results show that the prepared LCMO thin films have a single phase and high crystalline quality. The remarkably large temperature coefficient of resistance (TCR) values (above 11 %/K) are observed in the all films. TCR value reaches 18 %/K on the film grown on 10 tilted substrate. The intensity of LIV signals monotonously increases with the tilting angles, and the largest signal is 148 mV with the fast time response 229 ns for the film grown on 15 tilted substrate. (orig.)

  3. SIMULACIÓN DE MONTE CARLO APLICADA A LA ESTIMACIÓN DE DEPRESIONES RÁPIDAS DE LA TENSIÓN EN REDES ELÉCTRICAS MONTE CARLO SIMULATION APPLIED TO THE ESTIMATION OF VOLTAGE DIPS IN ELECTRIC NETWORKS

    Directory of Open Access Journals (Sweden)

    Miguel Arias Albornoz

    2008-09-01

    Full Text Available En este trabajo se aplica el método de simulación de Monte Carlo (MC para estimar el número de depresiones rápidas de tensión (dips esperados en barras de una red eléctrica. Las estimaciones obtenidas a través de MC se comparan con los resultados de otro método de cálculo conocido como Método de Posiciones de Falla (MPF. Entre los resultados se muestra tanto la convergencia del algoritmo MC a los valores de largo plazo del método MPF como la distribución completa de frecuencias para diferentes eventos, lo cual representa información valiosa para apoyar la toma de decisiones sobre el empleo de equipos sensibles a este tipo de perturbación.In this work, the Monte Carlo simulation method (MC is applied to estimate the number of expected voltage dips in the nodes of an electric network. The estimations obtained through MC are compared with the results of another method of calculation, known as Failure Position Method (MPF. In the results, both the convergence of the algorithm with the long-term values of the MPF method and the complete distribution of frequencies for different events are shown. This represents valuable information to support the decision-making process for equipment that is sensitive to this type of perturbation.

  4. PLZT light transmittance memory driven with an asymmetric voltage pulse

    International Nuclear Information System (INIS)

    Inoue, Kazuhiko; Morita, Takeshi

    2010-01-01

    PLZT is a ferroelectric electro-optic material, which has been operated with a constant voltage supply to keep a certain optical property. In this study, we propose an optical transmittance memory effect by controlling the domain conditions. The keypoint is to use an asymmetric voltage pulse. In the positive direction, a sufficiently-large voltage is applied to align the polarization directions. After this operation, a relatively small light transmittance is memorized even after removing the electric field. On the other hand, in the negative direction, the amplitude of the voltage is adjusted to the coercive electric field. In this condition, the domain structure is almost the same as the depolarization state. With this voltage supply, the maximum light transmittance can be kept after removing the electric field. Using these voltage operations, the PLZT can obtain two light transmittance states depending on the domain structure. This memory effect should be useful for innovative optical scanners or shutters in the future.

  5. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  6. Enhanced Local Grid Voltage Support Method for High Penetration of Distributed Generators

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Rodriguez, Pedro

    2011-01-01

    Grid voltage rise and thermal loading of network components are the most remarkable barriers to allow high number of distributed generator (DG) connections on the medium voltage (MV) and low voltage (LV) electricity networks. The other barriers such as grid power quality (harmonics, voltage...

  7. Casebook on electric safety accidents

    International Nuclear Information System (INIS)

    1987-09-01

    This book gives concentration on electric safety accidents in domestic and abroad, which introduces general electrical safety with property of electricity, safe equipment and maintenance and protection of electric shock. It lists the cases of accident caused of electricity in domestic like accident in power substation, utilization equipment, load system and another accident by electricity like death in electric shock another by electricity like death in electric shock in new building construction, the cases caused of electricity in abroad like damage in electric shock by high voltage electric transformer, electric shock in summer and earth fault accident by fault cooling tower.

  8. Model for the ready definition and approximate comparison of alternative high voltage transmission systems. Phases II and III. Application to electric systems within the contiguous United States. [800 and 1200 kV; 400, 600, and 800 kV dc

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    Research on power delivery alternatives is reported. The first phase of this work was to develop a model of overhead transmission systems in the range of 362 to 1200 kV ac, and +-400 to +-800 kV dc. Such systems included transmission from generation to load and inter-connection of two large integrated systems, with and without the existence of an underlying lower voltage network in either case. This phase has been completed. The second and third phases involved application of the model to electric systems within selected regions of the US, and the entire US, respectively, dealing with real situations and including projected expansion to year 1987. The potential benefits and costs of using higher than existing transmission voltages were to be evaluated on this basis. Additionally, the most advantageous new voltage was to be determined taking into account direct and indirect benefits and costs. The results of the second and third phases are presented.

  9. Electric voltage generation by antiferromagnetic dynamics

    Czech Academy of Sciences Publication Activity Database

    Yamane, Y.; Ieda, J.; Sinova, Jairo

    2016-01-01

    Roč. 93, č. 18 (2016), s. 1-5, č. článku 180408. ISSN 2469-9950 R&D Projects: GA ČR GB14-37427G; GA MŠk(CZ) LM2011026 Institutional support: RVO:68378271 Keywords : ferromagnets * force * driven Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.836, year: 2016

  10. Control Method for DC-Link Voltage Ripple Cancellation in Voltage Source Inverter under Unbalanced Three-Phase Voltage Supply Conditions

    Czech Academy of Sciences Publication Activity Database

    Chomát, Miroslav; Schreier, Luděk

    2005-01-01

    Roč. 152, č. 3 (2005), s. 494-500 ISSN 1350-2352 R&D Projects: GA ČR(CZ) GA102/02/0554 Institutional research plan: CEZ:AV0Z20570509 Keywords : DC-link voltage * unbalanced three-phase voltage Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.587, year: 2005

  11. Induced Voltage in an Open Wire

    Science.gov (United States)

    Morawetz, K.; Gilbert, M.; Trupp, A.

    2017-07-01

    A puzzle arising from Faraday's law has been considered and solved concerning the question which voltage will be induced in an open wire with a time-varying homogeneous magnetic field. In contrast to closed wires where the voltage is determined by the time variance of the magnetic field and the enclosed area, in an open wire we have to integrate the electric field along the wire. It is found that the longitudinal electric field with respect to the wave vector contributes with 1/3 and the transverse field with 2/3 to the induced voltage. In order to find the electric fields the sources of the magnetic fields are necessary to know. The representation of a spatially homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or symmetry line which depend on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to this symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire placed with different angles in the magnetic field. We present exactly solvable models of the Maxwell equations for a symmetry point and for a symmetry line, respectively. The results are applicable to open circuit problems like corrosion and for astrophysical applications.

  12. Development of Multi-Functional Voltage Restore System

    Science.gov (United States)

    Suzuki, Satoshi; Ueda, Yoshinobu; Koganezawa, Takehisa; Ogihara, Yoshinori; Mori, Kenjiro; Fukazu, Naoaki

    Recently, with the dawn of the electric deregulation, the installation of distributed generation with power electronics device has grown. This current causes a greater concern of power quality, primarily voltage disturbance for power companies, and their interest in power quality is peaking. Utilities are also interested in keeping their customers satisfied, as well as keeping them on-line and creating more revenue for the utility. As a countermeasure against the above surroundings, a variety type of devices based on power electronics has been developed to protect customers' load from power line voltage disturbance. One of them is the series type voltage restore. The series device is an active device, designed to provide a pure sinusoidal load voltage at all times, correcting voltage disturbance. Series type device compensates for voltage anomalies by inserting the ‘missing’ voltage onto the line through insertion transformer and inverter. This paper shows the setting guideline of target level to compensate voltage disturbance, that is, voltage dip, voltage harmonics, voltage imbalance and voltage flicker, and the design approach of the prototype of series voltage restores to accomplish the required compensation level. The prototype system gives satisfactory compensation performance through evaluation tests, which confirm the validity and effectiveness of the system.

  13. Electrical transformer handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Horne, D. (eds.)

    2005-07-01

    This handbook is a valuable user guide intended for electrical engineering and maintenance personnel, electrical contractors and electrical engineering students. It provides current information on techniques and technologies that can help extend the life of transformers. It discusses transformer testing, monitoring, design, commissioning, retrofitting and other elements involved in keeping electrical transformers in safe and efficient operation. It demonstrates how a power transformer can be put to use and common problems faced by owners. In addition to covering control techniques, testing and maintenance procedures, this handbook covers the power transformer; control electrical power transformer; electrical power transformer; electrical theory transformer; used electrical transformer; down electrical step transformer; electrical manufacturer transformer; electrical picture transformer; electrical transformer work; electrical surplus transformer; current transformer; step down transformer; voltage transformer; step up transformer; isolation transformer; low voltage transformer; toroidal transformer; high voltage transformer; and control power transformer. The handbook includes articles from leading experts on overcurrent protection of transformers; ventilated dry-type transformers; metered load factors for low-voltage, and dry-type transformers in buildings. The maintenance of both dry-type or oil-filled transformers was discussed with reference to sealing, gaskets, oils, moisture and testing. The adoption of dynamic load practices was also discussed along with the reclamation or recycling of used lube oil, transformer dielectric fluids and aged solid insulation. A buyer's guide and directory of transformer manufacturers and suppliers was also included. refs., tabs., figs.

  14. Fiber-optic voltage measuring system

    Science.gov (United States)

    Ye, Miaoyuan; Nie, De-Xin; Li, Yan; Peng, Yu; Lin, Qi-Qing; Wang, Jing-Gang

    1993-09-01

    A new fibre optic voltage measuring system has been developed based on the electrooptic effect of bismuth germanium oxide (Bi4Ge3O12)crystal. It uses the LED as the light source. The light beam emitted from the light source is transmitted to the sensor through the optic fibre and the intensity of the output beam is changed by the applied voltage. This optic signal is transmitted to the PIN detector and converted to an electric signal which is processed by the electronic circuit and 8098 single chip microcomputer the output voltage signal obtained is directly proportional to the applied voltage. This paper describes the principle the configuration and the performance parameters of the system. Test results are evaluated and discussed.

  15. Low voltage electron beam accelerators

    International Nuclear Information System (INIS)

    Ochi, Masafumi

    2003-01-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  16. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  17. High voltage capacitor design and the determination of solid dielectric voltage breakdown

    International Nuclear Information System (INIS)

    Hutapea, S.

    1976-01-01

    The value of the external field intensity serves as an electrical insulating material and is a physical characteristic of the substance. Capacitor discharge in the dielectric medium are experimentally investigated. The high voltage power supply and other instrument needed are briefly discussed. Capacitors with working voltage of 30.000 volt and the plastic being used for dielectrics in the capacitors are also discussed. (author)

  18. Strategic Sustainable Electric Power Energy for Ethiopia:- Electric ...

    African Journals Online (AJOL)

    Mengesha

    Present trend in electrical engineering education; ... (EERS) USA plans to reduce its electric energy ... at the distribution center, step-down to low voltage. (400 V .... Ethiopian market and in use [13]. .... involved in the teaching EEPCo students.

  19. Flame spread over inclined electrical wires with AC electric fields

    KAUST Repository

    Lim, Seung J.; Park, Sun H.; Park, Jeong; Fujita, Osamu; Keel, Sang I.; Chung, Suk-Ho

    2017-01-01

    Flame spread over polyethylene-insulated electrical wires was studied experimentally with applied alternating current (AC) by varying the inclination angle (θ), applied voltage (VAC), and frequency (fAC). For the baseline case with no electric field

  20. Exploration of genetically encoded voltage indicators based on a chimeric voltage sensing domain

    Directory of Open Access Journals (Sweden)

    Yukiko eMishina

    2014-09-01

    Full Text Available Deciphering how the brain generates cognitive function from patterns of electrical signals is one of the ultimate challenges in neuroscience. To this end, it would be highly desirable to monitor the activities of very large numbers of neurons while an animal engages in complex behaviours. Optical imaging of electrical activity using genetically encoded voltage indicators (GEVIs has the potential to meet this challenge. Currently prevalent GEVIs are based on the voltage-sensitive fluorescent protein (VSFP prototypical design or on the voltage dependent state transitions of microbial opsins.We recently introduced a new VSFP design in which the voltage-sensing domain (VSD is sandwiched between a FRET pair of fluorescent proteins (termed VSFP-Butterflies and also demonstrated a series of chimeric VSD in which portions of the VSD of Ciona intestinalis voltage-sensitive phosphatase (Ci-VSP are substituted by homologous portions of a voltage-gated potassium channel subunit. These chimeric VSD had faster sensing kinetics than that of the native Ci-VSD. Here, we describe a new set of VSFPs that combine chimeric VSD with the Butterfly structure. We show that these chimeric VSFP-Butterflies can report membrane voltage oscillations of up to 200 Hz in cultured cells and report sensory evoked cortical population responses in living mice. This class of GEVIs may be suitable for imaging of brain rhythms in behaving mammalians.

  1. Exploration of genetically encoded voltage indicators based on a chimeric voltage sensing domain.

    Science.gov (United States)

    Mishina, Yukiko; Mutoh, Hiroki; Song, Chenchen; Knöpfel, Thomas

    2014-01-01

    Deciphering how the brain generates cognitive function from patterns of electrical signals is one of the ultimate challenges in neuroscience. To this end, it would be highly desirable to monitor the activities of very large numbers of neurons while an animal engages in complex behaviors. Optical imaging of electrical activity using genetically encoded voltage indicators (GEVIs) has the potential to meet this challenge. Currently prevalent GEVIs are based on the voltage-sensitive fluorescent protein (VSFP) prototypical design or on the voltage-dependent state transitions of microbial opsins. We recently introduced a new VSFP design in which the voltage-sensing domain (VSD) is sandwiched between a fluorescence resonance energy transfer pair of fluorescent proteins (termed VSFP-Butterflies) and also demonstrated a series of chimeric VSD in which portions of the VSD of Ciona intestinalis voltage-sensitive phosphatase are substituted by homologous portions of a voltage-gated potassium channel subunit. These chimeric VSD had faster sensing kinetics than that of the native Ci-VSD. Here, we describe a new set of VSFPs that combine chimeric VSD with the Butterfly structure. We show that these chimeric VSFP-Butterflies can report membrane voltage oscillations of up to 200 Hz in cultured cells and report sensory evoked cortical population responses in living mice. This class of GEVIs may be suitable for imaging of brain rhythms in behaving mammalians.

  2. Electric circuits and signals

    CERN Document Server

    Sabah, Nassir H

    2007-01-01

    Circuit Variables and Elements Overview Learning Objectives Electric Current Voltage Electric Power and Energy Assigned Positive Directions Active and Passive Circuit Elements Voltage and Current Sources The Resistor The Capacitor The Inductor Concluding Remarks Summary of Main Concepts and Results Learning Outcomes Supplementary Topics on CD Problems and Exercises Basic Circuit Connections and Laws Overview Learning Objectives Circuit Terminology Kirchhoff's Laws Voltage Division and Series Connection of Resistors Current Division and Parallel Connection of Resistors D-Y Transformation Source Equivalence and Transformation Reduced-Voltage Supply Summary of Main Concepts and Results Learning Outcomes Supplementary Topics and Examples on CD Problems and Exercises Basic Analysis of Resistive Circuits Overview Learning Objectives Number of Independent Circuit Equations Node-Voltage Analysis Special Considerations in Node-Voltage Analysis Mesh-Current Analysis Special Conside...

  3. Bidirectional current-voltage converters based on magnetostrictive/piezoelectric composites

    NARCIS (Netherlands)

    Jia, Y.; Or, S.W.; Chan, H.L.W.; Jiao, J.; Luo, H.; Van der Zwaag, S.

    2009-01-01

    We report a power supply-free, bidirectional electric current-voltage converter based on a coil-wound laminated composite of magnetostrictive alloy and piezoelectric crystal. An electric current applied to the coil induces a magnetic field, resulting in an electric voltage from the composite due to

  4. Contributions of counter-charge in a potassium channel voltage-sensor domain

    DEFF Research Database (Denmark)

    Pless, Stephan Alexander; Galpin, Jason D; Niciforovic, Ana P

    2011-01-01

    Voltage-sensor domains couple membrane potential to conformational changes in voltage-gated ion channels and phosphatases. Highly coevolved acidic and aromatic side chains assist the transfer of cationic side chains across the transmembrane electric field during voltage sensing. We investigated...... the functional contribution of negative electrostatic potentials from these residues to channel gating and voltage sensing with unnatural amino acid mutagenesis, electrophysiology, voltage-clamp fluorometry and ab initio calculations. The data show that neutralization of two conserved acidic side chains...

  5. A nanoscale piezoelectric transformer for low-voltage transistors.

    Science.gov (United States)

    Agarwal, Sapan; Yablonovitch, Eli

    2014-11-12

    A novel piezoelectric voltage transformer for low-voltage transistors is proposed. Placing a piezoelectric transformer on the gate of a field-effect transistor results in the piezoelectric transformer field-effect transistor that can switch at significantly lower voltages than a conventional transistor. The piezoelectric transformer operates by using one piezoelectric to squeeze another piezoelectric to generate a higher output voltage than the input voltage. Multiple piezoelectrics can be used to squeeze a single piezoelectric layer to generate an even higher voltage amplification. Coupled electrical and mechanical modeling in COMSOL predicts a 12.5× voltage amplification for a six-layer piezoelectric transformer. This would lead to more than a 150× reduction in the power needed for communications.

  6. Harmonic current interaction at a low voltage customer's installations

    NARCIS (Netherlands)

    Bhattacharyya, S.; Myrzik, J.M.A.; Kling, W.L.; Cobben, J.F.G.; Casteren, van J.

    2009-01-01

    The increased uses of power electronics and switching devices in the electricity network have changed the operational environment of the power system. These devices have nonlinear voltage-current characteristics and produce harmonic currents, and consequently distort the voltage waveform. A low

  7. Comparison CCEM-K8 of DC voltage ratio: results

    CSIR Research Space (South Africa)

    Marullo-Reedtz, G

    2003-04-01

    Full Text Available , he has been with VNIIM where he has been involved in inves- tigation and development of electrical standards of dc voltage and dc current, using quantum effects in LT- and HT-superconductors and ratio voltage mea- surement up to 1000 V. Ronald...

  8. Loss Minimization and Voltage Control in Smart Distribution Grid

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for increasing the installation of electric vehicles and solar panels in low-voltage grids, while obeying voltage variation constraints. Our approach employs minimization of active power losses for coordinating consumption and generation of power, as well as reactive...

  9. Precision High-Voltage DC Dividers and Their Calibration

    Czech Academy of Sciences Publication Activity Database

    Dragounová, Naděžda

    2005-01-01

    Roč. 54, č. 5 (2005), s. 1911-1915 ISSN 0018-9456 R&D Projects: GA AV ČR KSK1048102; GA ČR GA202/03/0889 Keywords : calibration * dc voltage * high voltage (HV) Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.665, year: 2005

  10. Dual voltage source inverter topology extending machine operating range

    NARCIS (Netherlands)

    Gerrits, T.; Wijnands, C.G.E.; Paulides, J.J.H.; Duarte, J.L.

    2012-01-01

    Field weakening operation of an electrical machine is a conventional method to extend the angular velocity range of a system above the peak output voltage of the inverter. A downside, however, is that an increased reactive current is required that creates losses but no output torque. A dual voltage

  11. Multi-objective optimization of distributed generation with voltage ...

    African Journals Online (AJOL)

    DR OKE

    1*Department of Electrical Engineering, Kamla Nehru Institute of Technology Sultanpurr, ... of DG in distribution systems for different voltage dependent load models and .... The evaluation of the objective function depends only on location, size ...

  12. PLL strategies of grid connected converters under distorted input voltages

    Czech Academy of Sciences Publication Activity Database

    Šimek, Petr; Škramlík, Jiří; Valouch, Viktor

    2014-01-01

    Roč. 59, č. 1 (2014), s. 1-12 ISSN 0001-7043 Institutional support: RVO:61388998 Keywords : voltage source converter * grid - connected applications * phase locked loop Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  13. Electrical system architecture

    Science.gov (United States)

    Algrain, Marcelo C [Peoria, IL; Johnson, Kris W [Washington, IL; Akasam, Sivaprasad [Peoria, IL; Hoff, Brian D [East Peoria, IL

    2008-07-15

    An electrical system for a vehicle includes a first power source generating a first voltage level, the first power source being in electrical communication with a first bus. A second power source generates a second voltage level greater than the first voltage level, the second power source being in electrical communication with a second bus. A starter generator may be configured to provide power to at least one of the first bus and the second bus, and at least one additional power source may be configured to provide power to at least one of the first bus and the second bus. The electrical system also includes at least one power consumer in electrical communication with the first bus and at least one power consumer in electrical communication with the second bus.

  14. Shaping the spectra of the line-to-line voltage using signal injection in the common mode voltage

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Rasmussen, Peter Omand; Pedersen, John Kim

    2009-01-01

    A drawback of Pulse Width Modulation in electrical drives is the high harmonic content of the line to line voltages, which gives rise to Electro-Magnetic Interference and acoustic noise. By injection of a signal into the common mode voltage, the fundamental is not affected, but new frequency...

  15. Dispersion of breakdown voltage of liquid helium

    International Nuclear Information System (INIS)

    Ishii, Itaru; Noguchi, Takuya

    1978-01-01

    As for the electrical insulation characteristics of liquid helium, the discrepancy among the measured values by each person is very large even in the fundamental DC breakdown voltage in uniform electric field. The dispersion of experimental values obtained in the experiments by the same person is also large. Hereafter, the difference among the mean values obtained by each experimenter will be referred to as ''deviation of mean values'', and the dispersion of measured values around the mean value obtained by the same person as ''deviation around the man value''. The authors have mainly investigated on the latter experimentally. The cryostat was made of stainless steel, and the innermost helium chamber was of 500 mm I.D. and approximately 1200 mm deep. The high voltage electrode was of brass sphere of 25 mm diameter, and the low voltage electrode was of brass plate. The experiment was conducted for liquid helium boiling at 4.2 K and 1 atm, and the breakdown voltage and time lag were measured by applying the approximately square wave impulses of fast rise and long tail, ramp and DC voltages. The cause of the deviation of mean values may be the presence of impurity particles or the effect of electrode shape. As for the deviation around the mean value, the dispersion is large, and its standard deviation may amount to 10 to 20% of the man value. The dispersion is not due to the statistical time lag, but is due to parameters that vary with breakdown. (Wakatsuki, Y.)

  16. based dynamic voltage restorer

    African Journals Online (AJOL)

    HOD

    operation due to presence of increased use of nonlinear loads (computers, microcontrollers ... simulations of a dynamic voltage restorer (DVR) was achieved using MATLAB/Simulink. ..... using Discrete PWM generator, then the IGBT inverter.

  17. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  18. Low-voltage gyrotrons

    International Nuclear Information System (INIS)

    Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S.; Nusinovich, G. S.

    2013-01-01

    For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5–10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%–2% in the submillimeter wavelength region).

  19. Voltage sags impact on CAR and SOR of HANARO

    International Nuclear Information System (INIS)

    Kim, Hyung Kyoo; Jung, Hoan Sung; Wu, Jong Sup

    2004-01-01

    The combination of the unstable electric power and sensitive equipment may cause the nuisance of reactor trip. The reactor is tripped by the RRS and RPS during the occurrence of the voltage sags or momentary interruptions. We tested the components of RRS and RPS for the immunity from voltage sags and momentary interruptions. The tested components are DC power supply for CAR (control absorbed rod) of RRS and AC coil contactor for SOR (shut off rod) of RPS. We briefly describe the power quality standard for the voltage sags. This paper summarizes the magnitudes and durations of the voltage sags which impact on the CAR and SOR system

  20. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...... either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load...

  1. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  2. Exercise-induced stunning continues for at least one hour: evaluation with quantitative gated single-photon emission tomography

    International Nuclear Information System (INIS)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Tsujimura, Eiichiro; Yamaguchi, Hitoshi; Tokita, Naoki; Maruyama, Atsushi; Xiuli, Mu; Nishimura, Tsunehiko

    1999-01-01

    To elucidate the after-effect of exercise on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated at 1 h after exercise and at rest by technetium-99m tetrofosmin gated myocardial single-photon emission tomography (SPET) using an automated program in 53 subjects. The subjects were grouped as follows: normal scan (n = 16), ischaemia (n = 19) and infarction (n = 18), based on the interpretation of perfusion images. Postexercise LVEF did not differ from resting LVEF in the groups with normal scan and infarction. In patients with ischaemia, postexercise EDV (90±17 ml, mean ±SD) and ESV (44±15 ml) were significantly higher than EDV (84±15 ml, P = 0.001) and ESV (36±14 ml, P<0.0005) at rest. LVEF was significantly depressed 1 h after exercise (53%±9% vs 58%±9%, P<0.0001). In ischaemic patients with depressed postexercise LVEF, LVEF difference between rest and postexercise showed a significant correlation with the sum of defect scores, which were reversible from exercise to rest perfusion images (r = 0.92, P<0.0001). These results indicate that exercise-induced LV dysfunction (myocardial stunning) continues for at least 1 h in ischaemic patients and that the extent of LVEF depression is determined by the severity of ischaemia. (orig.)

  3. Exercise-induced stunning continues for at least one hour: evaluation with quantitative gated single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Tsujimura, Eiichiro; Yamaguchi, Hitoshi; Tokita, Naoki; Maruyama, Atsushi; Xiuli, Mu; Nishimura, Tsunehiko [Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Suita, Osaka (Japan)

    1999-04-29

    To elucidate the after-effect of exercise on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated at 1 h after exercise and at rest by technetium-99m tetrofosmin gated myocardial single-photon emission tomography (SPET) using an automated program in 53 subjects. The subjects were grouped as follows: normal scan (n = 16), ischaemia (n = 19) and infarction (n = 18), based on the interpretation of perfusion images. Postexercise LVEF did not differ from resting LVEF in the groups with normal scan and infarction. In patients with ischaemia, postexercise EDV (90{+-}17 ml, mean {+-}SD) and ESV (44{+-}15 ml) were significantly higher than EDV (84{+-}15 ml, P = 0.001) and ESV (36{+-}14 ml, P<0.0005) at rest. LVEF was significantly depressed 1 h after exercise (53%{+-}9% vs 58%{+-}9%, P<0.0001). In ischaemic patients with depressed postexercise LVEF, LVEF difference between rest and postexercise showed a significant correlation with the sum of defect scores, which were reversible from exercise to rest perfusion images (r = 0.92, P<0.0001). These results indicate that exercise-induced LV dysfunction (myocardial stunning) continues for at least 1 h in ischaemic patients and that the extent of LVEF depression is determined by the severity of ischaemia. (orig.) With 7 figs., 19 refs.

  4. Electric theory

    International Nuclear Information System (INIS)

    Gong, Ha Seong

    2006-02-01

    This book explains electric theory which is divided into four chapters. The first chapter includes electricity and material, electric field, capacitance, magnetic field and electromagnetic force, inductance. The second chapter mentions electronic circuit analysis, electric resistance,heating and power, chemical activity on current and battery with electrolysis. The third chapter deals with an alternating current circuit about the basics of an AC circuit, operating of resistance, inductance and capacitance, series circuit and parallel circuit of PLC, an alternating current circuit, Three-phase Alternating current, two terminal pair network and voltage and current of non-linearity circuit. The last explains transient phenomena of RC series circuit, RL series circuit, transient phenomena of an alternating current circuit and transient phenomena of RLC series circuit.

  5. Voltages and electric currents mensuration - class 15 kV - for systems electro-optical and magneto-optical; Medicao de tensoes e correntes - classe 15 kv - por sistemas eletro-opticos e magneto-opticos

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Marcos Rodrigues

    1996-07-01

    The technical feasibility of the development of a novel system measuring of high voltage and current in 15 kV distribution lines was presented. The system is basically the combination of two other systems, one conventional and other electro-optical. The conventional subsystem is based on voltage dividers and magnetic rings while the electro-optical subsystem uses LEDs, resistors, optical-fibers and photodetectors. The system was completely tested in laboratory and its main characteristics are low price, easy of installation and flexibility. Two software for data acquisition by GPIB and A/D boards were also developed. The can provide reports on voltages, currents, power and phase-power. (author)

  6. Conservation voltage regulation (CVR) applied to energy savings by voltage-adjusting equipment through AMI

    Science.gov (United States)

    Lan, B.-R.; Chang, C.-A.; Huang, P.-Y.; Kuo, C.-H.; Ye, Z.-J.; Shen, B.-C.; Chen, B.-K.

    2017-11-01

    Conservation voltage reduction (CVR) includes peak demand reduction, energy conservation, carbon emission reduction, and electricity bill reduction. This paper analyzes the energy-reduction of Siwei Feeders with applying CVR, which are situated in Penghu region and equipped with smart meters. Furthermore, the applicable voltage reduction range for the feeders will be explored. This study will also investigate how the CVR effect and energy conservation are improved with the voltage control devices integrated. The results of this study can serve as a reference for the Taiwan Power Company to promote and implement voltage reduction and energy conservation techniques. This study is expected to enhance the energy-reduction performance of the Penghu Low Carbon Island Project.

  7. Structural mechanism of voltage-dependent gating in an isolated voltage-sensing domain.

    Science.gov (United States)

    Li, Qufei; Wanderling, Sherry; Paduch, Marcin; Medovoy, David; Singharoy, Abhishek; McGreevy, Ryan; Villalba-Galea, Carlos A; Hulse, Raymond E; Roux, Benoît; Schulten, Klaus; Kossiakoff, Anthony; Perozo, Eduardo

    2014-03-01

    The transduction of transmembrane electric fields into protein motion has an essential role in the generation and propagation of cellular signals. Voltage-sensing domains (VSDs) carry out these functions through reorientations of positive charges in the S4 helix. Here, we determined crystal structures of the Ciona intestinalis VSD (Ci-VSD) in putatively active and resting conformations. S4 undergoes an ~5-Å displacement along its main axis, accompanied by an ~60° rotation. This movement is stabilized by an exchange in countercharge partners in helices S1 and S3 that generates an estimated net charge transfer of ~1 eo. Gating charges move relative to a ''hydrophobic gasket' that electrically divides intra- and extracellular compartments. EPR spectroscopy confirms the limited nature of S4 movement in a membrane environment. These results provide an explicit mechanism for voltage sensing and set the basis for electromechanical coupling in voltage-dependent enzymes and ion channels.

  8. Ion peak narrowing by applying additional AC voltage (ripple voltage) to FAIMS extractor electrode.

    Science.gov (United States)

    Pervukhin, Viktor V; Sheven, Dmitriy G

    2010-01-01

    The use of a non-uniform electric field in a high-field asymmetric waveform ion mobility spectrometry (FAIMS) analyzer increases sensitivity but decreases resolution. The application of an additional AC voltage to the extractor electrode ("ripple" voltage, U(ripple)) can overcome this effect, which decreases the FAIMS peak width. In this approach, the diffusion ion loss remains minimal in the non-uniform electric field in the cylindrical part of the device, and all ion losses under U(ripple) occur in a short portion of their path. Application of the ripple voltage to the extractor electrode is twice as efficient as the applying of U(ripple) along the total length of the device. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  9. Intermediate state trapping of a voltage sensor

    DEFF Research Database (Denmark)

    Lacroix, Jérôme J; Pless, Stephan Alexander; Maragliano, Luca

    2012-01-01

    Voltage sensor domains (VSDs) regulate ion channels and enzymes by undergoing conformational changes depending on membrane electrical signals. The molecular mechanisms underlying the VSD transitions are not fully understood. Here, we show that some mutations of I241 in the S1 segment of the Shaker...... Kv channel positively shift the voltage dependence of the VSD movement and alter the functional coupling between VSD and pore domains. Among the I241 mutants, I241W immobilized the VSD movement during activation and deactivation, approximately halfway between the resting and active states......, and drastically shifted the voltage activation of the ionic conductance. This phenotype, which is consistent with a stabilization of an intermediate VSD conformation by the I241W mutation, was diminished by the charge-conserving R2K mutation but not by the charge-neutralizing R2Q mutation. Interestingly, most...

  10. Voltage control of cavity magnon polariton

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, S., E-mail: kaurs3@myumanitoba.ca; Rao, J. W.; Gui, Y. S.; Hu, C.-M., E-mail: hu@physics.umanitoba.ca [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); Yao, B. M. [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); National Laboratory for Infrared Physics, Chinese Academy of Sciences, Shanghai 200083 (China)

    2016-07-18

    We have experimentally investigated the microwave transmission of the cavity-magnon-polariton (CMP) generated by integrating a low damping magnetic insulator onto a 2D microwave cavity. The high tunability of our planar cavity allows the cavity resonance frequency to be precisely controlled using a DC voltage. By appropriately tuning the voltage and magnetic bias, we can observe the cavity photon magnon coupling and the magnetic coupling between a magnetostatic mode and the generated CMP. The dispersion of the generated CMP was measured by either tuning the magnetic field or the applied voltage. This electrical control of CMP may open up avenues for designing advanced on-chip microwave devices that utilize light-matter interaction.

  11. High voltage load resistor array

    Science.gov (United States)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  12. Technique eliminates high voltage arcing at electrode-insulator contact area

    Science.gov (United States)

    Mealy, G.

    1967-01-01

    Coating the electrode-insulator contact area with silver epoxy conductive paint and forcing the electrode and insulator tightly together into a permanent connection, eliminates electrical arcing in high-voltage electrodes supplying electrical power to vacuum facilities.

  13. High voltage traction power supply; Ein- und Mehrspannungssysteme in der Bahnenergieversorgung mit hohen Spannungen

    Energy Technology Data Exchange (ETDEWEB)

    Borchard, Ludwig O. [Transnet freight rail, (Technology Management), Braamfontein (South Africa); Lehmann, Michael [Technische Univ. Dresden (Germany). Professur Elektrische Bahnen

    2009-04-15

    Raising the nominal voltage of electric railway systems implies many advantages, therefore several concepts can be presented and compared. Detailed studies on two systems with high contact line voltages were performed for the upgrade of the 1 AC 50 kV railway line in South Africa. Finally requirements for high voltage locomotives are derived and illustrated by examples. (orig.)

  14. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley...

  15. 30 CFR 77.515 - Bare signal or control wires; voltage.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare signal or control wires; voltage. 77.515 Section 77.515 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Electrical Equipment-General § 77.515 Bare signal or control wires; voltage. The voltage on...

  16. High frequency breakdown voltage

    International Nuclear Information System (INIS)

    Chu, Thanh Duy.

    1992-03-01

    This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O degrees C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f c , the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, the second critical frequency, f ce , is reached. This time the electrons start being trapped in the gap. Those electrons that travel multiple times across the gap before reaching the positive electrode result in an enormous number of electrons and positive ions being present in the gap. The result is a further decrease of the breakdown voltage. However, increasing the frequency does not decrease the breakdown voltage correspondingly. In fact, the associated breakdown field intensity is almost constant (about 29 kV/cm).The reason is that the recombination rate increases and counterbalances the production rate, thus reducing the effect of the positive ions' concentration in the gap. The theory of collision and ionization does not apply to the breakdown in vacuum. It seems that the breakdown in vacuum is primarily determined by the irregularities on the surfaces of the electrodes. Therefore, the effect of frequency on the breakdown, if any, is of secondary importance

  17. Voltage breakdown on niobium and copper surfaces

    International Nuclear Information System (INIS)

    Werner, G.R.; Padamsee, H.; Betzwieser, J.C.; Liu, Y.G.; Rubin, K.H.R.; Shipman, J.E.; Ying, L.T.

    2003-01-01

    Experiments have shown that voltage breakdown in superconducting niobium RF cavities is in many ways similar to voltage breakdown on niobium cathodes in DC voltage gaps; most striking are the distinctive starburst patterns and craters that mark the site of voltage breakdown in both superconducting cavities and DC vacuum gaps. Therefore, we can learn much about RF breakdown from simpler, faster DC experiments. We have direct evidence, in the form of before'' and ''after'' pictures, that breakdown events caused by high surface electric fields occur with high probability at contaminant particles on surfaces. Although the pre-breakdown behavior (field emission) seems to depend mostly on the contaminant particles present and little on the substrate, the breakdown event itself is greatly affected by the substrate-niobium, heavily oxidized niobium, electropolished copper, and diamond-machined copper cathodes lead to different kinds of breakdown events. By studying DC voltage breakdown we hope to learn more details about the processes involved in the transition from field emission to catastrophic arcing and the cratering of the surface; as well as learning how to prevent breakdown, we would like to learn how to cause breakdown, which could be important when ''processing'' cavities to reduce field emission. (author)

  18. High-voltage polymeric insulated cables

    Energy Technology Data Exchange (ETDEWEB)

    Ross, A

    1987-01-01

    Reviews developments in high-voltage (here defined as 25 kV, 66 kV and 132 kV) polymeric insulated cables in the UK over the period 1979-1986, with particular reference to the experience of the Eastern Electricity Board. Outlines the background to the adoption of XPLE-insulated solid cable, and the design, testing, terminations, jointing and costs of 25 kV, 66 kV and 132 kV cables.

  19. Digital voltage discriminator

    International Nuclear Information System (INIS)

    Zhou Zhicheng

    1992-01-01

    A digital voltage discriminator is described, which is synthesized by digital comparator and ADC. The threshold is program controllable with high stability. Digital region of confusion is approximately equal to 1.5 LSB. This discriminator has a single channel analyzer function model with channel width of 1.5 LSB

  20. High-voltage picoamperemeter

    Energy Technology Data Exchange (ETDEWEB)

    Bugl, Andrea; Ball, Markus; Boehmer, Michael; Doerheim, Sverre; Hoenle, Andreas; Konorov, Igor [Technische Universitaet Muenchen, Garching (Germany); Ketzer, Bernhard [Technische Universitaet Muenchen, Garching (Germany); Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2014-07-01

    Current measurements in the nano- and picoampere region on high voltage are an important tool to understand charge transfer processes in micropattern gas detectors like the Gas Electron Multiplier (GEM). They are currently used to e.g. optimize the field configuration in a multi-GEM stack to be used in the ALICE TPC after the upgrade of the experiment during the 2nd long shutdown of the LHC. Devices which allow measurements down to 1pA at high voltage up to 6 kV have been developed at TU Muenchen. They are based on analog current measurements via the voltage drop over a switchable shunt. A microcontroller collects 128 digital ADC values and calculates their mean and standard deviation. This information is sent with a wireless transmitting unit to a computer and stored in a root file. A nearly unlimited number of devices can be operated simultaneously and read out by a single receiver. The results can also be displayed on a LCD directly at the device. Battery operation and the wireless readout are important to protect the user from any contact to high voltage. The principle of the device is explained, and systematic studies of their properties are shown.