WorldWideScience

Sample records for electre iii method

  1. Electre III method in assessment of variants of integrated urban public transport system in Cracow

    Directory of Open Access Journals (Sweden)

    Katarzyna SOLECKA

    2014-12-01

    Full Text Available There is a lot of methods which are currently used for assessment of urban public transport system development and operation e.g. economic analysis, mostly Cost-Benefit Analysis – CBA, Cost-Effectiveness Analysis - CEA, hybrid methods, measurement methods (survey e.g. among passengers and measurement of traffic volume, vehicles capacity etc., and multicriteria decision aiding methods (multicriteria analysis. The main aim of multicriteria analysis is the choice of the most desirable solution from among alternative variants according to different criteria which are difficult to compare against one another. There are several multicriteria methods for assessment of urban public transport system development and operation, e.g. AHP, ANP, Electre, Promethee, Oreste. The paper presents an application of one of the most popular variant ranking methodsElectre III method. The algorithm of Electre III method usage is presented in detail and then its application for assessment of variants of urban public transport system integration in Cracow is shown. The final ranking of eight variants of integration of urban public transport system in Cracow (from the best to the worst variant was drawn up with the application of the Electre III method. For assessment purposes 10 criteria were adopted: economical, technical, environmental, and social; they form a consistent criteria family. The problem was analyzed with taking into account different points of view: city authorities, public transport operators, city units responsible for transport management, passengers and others users. Separate models of preferences for all stakeholders were created.

  2. A new view to uncertainty in Electre III method by introducing interval numbers

    Directory of Open Access Journals (Sweden)

    Mohammad Kazem Sayyadi

    2012-07-01

    Full Text Available The Electre III is a widely accepted multi attribute decision making model, which takes into account the uncertainty and vagueness. Uncertainty concept in Electre III is introduced by indifference, preference and veto thresholds, but sometimes determining their accurate values can be very hard. In this paper we represent the values of performance matrix as interval numbers and we define the links between interval numbers and concordance matrix .Without changing the concept of concordance, in our propose concept, Electre III is usable in decision making problems with interval numbers.

  3. Electrical properties of dislocations in III-Nitrides

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcoli, D.; Minj, A.; Pandey, S.; Cavallini, A. [Physics and Astronomy Dept. University of Bologna, Italy viale C Berti Pichat 6/II, Bologna (Italy)

    2014-02-21

    Research on GaN, AlN, InN (III-N) and their alloys is achieving new heights due their high potential applications in photonics and electronics. III-N semiconductors are mostly grown epitaxially on sapphire, and due to the large lattice mismatch and the differences in the thermal expansion coefficients, the structures usually contain many threading dislocations (TDs). While their structural properties have been widely investigated, their electrical characteristics and their role in the transport properties of the devices are still debated. In the present contribution we will show conductive AFM studies of TDs in GaN and Al/In GaN ternary alloys to evidence the role of strain, different surface polarity and composition on their electrical properties. Local I-V curves measured at TDs allowed us to clarify their role in the macroscopic electrical properties (leakage current, mobilities) of III-N based devices. Samples obtained by different growers (AIXTRON, III-V Lab) were studied. The comparison between the results obtained in the different alloys allowed us to understand the role of In and Al on the TDs electrical properties.

  4. Electrical properties of dislocations in III-Nitrides

    Science.gov (United States)

    Cavalcoli, D.; Minj, A.; Pandey, S.; Cavallini, A.

    2014-02-01

    Research on GaN, AlN, InN (III-N) and their alloys is achieving new heights due their high potential applications in photonics and electronics. III-N semiconductors are mostly grown epitaxially on sapphire, and due to the large lattice mismatch and the differences in the thermal expansion coefficients, the structures usually contain many threading dislocations (TDs). While their structural properties have been widely investigated, their electrical characteristics and their role in the transport properties of the devices are still debated. In the present contribution we will show conductive AFM studies of TDs in GaN and Al/In GaN ternary alloys to evidence the role of strain, different surface polarity and composition on their electrical properties. Local I-V curves measured at TDs allowed us to clarify their role in the macroscopic electrical properties (leakage current, mobilities) of III-N based devices. Samples obtained by different growers (AIXTRON, III-V Lab) were studied. The comparison between the results obtained in the different alloys allowed us to understand the role of In and Al on the TDs electrical properties.

  5. OPTIMASI PEMILIHAN LOKASI FASILITAS PENGOLAHAN LIMBAH ELEKTRONIK (E-WASTE DI INDONESIA DENGAN MODEL ELECTRE III

    Directory of Open Access Journals (Sweden)

    Pertiwi Andarani

    2015-01-01

    Full Text Available Limbah elektronik adalah masalah yang muncul di Indonesia karena mengandung bahan yang berpotensi berbahaya. Dalam rangka menciptakan manajemen yang ramah lingkungan dari limbah elektronik, fasilitas yang memadai diperlukan. Tujuan dari penelitian ini adalah untuk memilih lokasi yang optimal untuk mengembangkan fasilitas pengolahan limbah elektronik (FLPE. Pemilihan lokasi yang optimal dilakukan dengan menggunakan metode model ELECTRE III. ELECTRE adalah keluarga metode analisis keputusan multi-kriteria yang berasal di Eropa. Kriteria yang dipilih untuk analisis ini adalah penduduk setempat, penduduk yang dilayani, persentase belanja bulanan, harga rata-rata rumah tangga per unit, populasi pengangguran, status finansial dari penduduk lokal, jarak dari fasilitas yang telah ada, dan jarak dari pelabuhan terdekat. ELECTRE III membutuhkan penentuan tiga ambang batas, yaitu ambang kelalaian (q, ambang batas preferensi (p, dan ambang veto (v dalam upaya untuk lebih beradaptasi dengan ketidakpastian. Bobot masing-masing kriteria yang ditentukan sesuai dengan kepentingan relatif terhadap kriteria lain. Lokasi optimal untuk FPLE adalah Provinsi Banten berdasarkan model ELECTRE III.   Kata Kunci: limbah elektronik, fasilitas, optimasi, ELECTRE Abstract E-waste is an emerging issue in Indonesia due to its potentially hazardous content and some precious metal. In order to create an environmentally sound management of e-waste, a facility is necessary. The objectives of this study are to to select the optimal location of e-waste dismantling and sorting facility (DSF/FLPE.  The optimal location selection was conducted using the method of ELECTRE III model. ELECTRE is a family of multi-criteria decision analysis methods that originated in Europe. The criteria chosen for this analysis are local population, population served, the percentage of monthly expenditure, average household price per unit, unemployed population, financial status of the local population

  6. Approach to Multi-Criteria Group Decision-Making Problems Based on the Best-Worst-Method and ELECTRE Method

    Directory of Open Access Journals (Sweden)

    Xinshang You

    2016-09-01

    Full Text Available This paper proposes a novel approach to cope with the multi-criteria group decision-making problems. We give the pairwise comparisons based on the best-worst-method (BWM, which can decrease comparison times. Additionally, our comparison results are determined with the positive and negative aspects. In order to deal with the decision matrices effectively, we consider the elimination and choice translation reality (ELECTRE III method under the intuitionistic multiplicative preference relations environment. The ELECTRE III method is designed for a double-automatic system. Under a certain limitation, without bothering the decision-makers to reevaluate the alternatives, this system can adjust some special elements that have the most influence on the group’s satisfaction degree. Moreover, the proposed method is suitable for both the intuitionistic multiplicative preference relation and the interval valued fuzzy preference relations through the transformation formula. An illustrative example is followed to demonstrate the rationality and availability of the novel method.

  7. Portfolio selection using ELECTRE III: Evidence from Tehran Stock Exchange

    Directory of Open Access Journals (Sweden)

    Aazam Shabani Vezmelai

    2015-04-01

    Full Text Available Ranking the companies can be a useful guide for investors to select an optimum portfolio. Tehran stock exchange (TSE uses liquidity criterion to rank the companies; however, this study shows that preferences of investors, the criteria they use to evaluate companies’ performances, and the extent to which ranking of companies based on investors’ criteria are in line with the ranking announced by the stock exchange. Since the criteria used for ranking the companies are various and often conflicting and because each multiple criteria technique has its own specific characteristics, various rankings are offered. Therefore, it is required to utilize multiple criteria decision making models to avoid confusion of investors. For this purpose, some companies were selected from 50 top companies listed in 2011 in TSE, which maintained the reliability of their ranks and finally, 20 companies were selected and were ranked based on investors’ criteria using EECTRE III Technique. The obtained ranking was then compared with the ranking offered by stock exchange. Research results indicate that ELECTRE III technique was a useful and efficient method to select a portfolio. Moreover, value-based criteria as well as accounting criteria are suitable and useful bases for investors to select a portfolio.

  8. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    Science.gov (United States)

    Chassin, David P [Pasco, WA; Donnelly, Matthew K [Kennewick, WA; Dagle, Jeffery E [Richland, WA

    2011-12-06

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  9. An integrated framework for outsourcing using balanced score card and ELECTRE III

    Directory of Open Access Journals (Sweden)

    Sareh Namazi

    2011-04-01

    Full Text Available During the past few decades, many organizations have attempted to increase their productivity through outsourcing parts of their responsibilities. Outsourcing helps firms reduce their low value added activities and focus on their high value added activities. It also helps organization save their time and energy which leads to more efficient units. The idea of outsourcing is more important for project based organizations where the nature of works is different from a particular project to another one. This paper presents an integrated balanced score card system with an adaptation of ELECTRE III method to select suitable resources for outsourcing. The proposed model of the paper is implemented for a case study of subway system in Iran and the results are discussed.

  10. Dependence of electrical property on the applied magnetic fields in spin coated Fe(III)-Phorphyrin films

    International Nuclear Information System (INIS)

    Utari; Kusumandari; Purnama, B.; Mudasir; Abraha, K.

    2016-01-01

    We report here on the experimental results of the effect of external magnetic field on the current flow in plane surface of Fe(III)-porphyrin thin layer. The deposition of the Fe(III)- porphyrin thin layer was done by spin coating method. The I-V characteristics of film were measured by means of two point probes. The sample of layer number N = 4 was used to evaluate the magnetic effect on the electrical currents. The ohmic characteristics of the I-V film measurement were obtained. The current decreases when magnetic field is applied to the system and saturated current is obtained at a given magnetic field. Here, the decrease in the current can be attributed to the recombination of carrier charge under the magnetic field. In addition, the magnitude of the saturated current is found to increase with the increase in the voltage used. (paper)

  11. Nitrato-complexes of Y(III), La(III), Ce(III), Pr(III), Nd(III), Sm(III), Gd(III), Tb(III), Dy(III) and Ho(III) with 2-(2'-pyridyl) benzimidazole

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, A; Singh, M P; Singh, V K

    1982-05-01

    The nitrato-complexes, (Y(PyBzH)/sub 2/(NO/sub 3/)/sub 2/)NO/sub 3/.H/sub 2/O and Nd, Sm, Gd, Tb, Dy, Ho ; n=1-3, m=0-0.5 ; PyBzh=2-(2 -pyridyl)benzimidazole) are formed on interaction of the ligand with metal nitrates in ethanol. The electrical conductance values (116-129 ohm/sup -1/cm/sup 2/mol/sup -1/) suggest 1:1 electrolyte-nature of the complexes. Magnetic moment values of Ce(2.53 B.M.), Pr(3.62 B.M.), Nd(3.52 B.M.), Sm(1.70 B.M.), Gd(8.06 B.M.), Tb(9.44 B.M.), Dy(10.56 B.M.) and Ho(10.51 B.M.) in the complexes confirm the positive state of the metals. Infrared evidences are obtained for the existance of both coordinated (C/sub 2/v) and uncoordinated (D/sub 3/h) nitrate groups. Electronic absorption spectra of Pr(III)-, Nd(III)-, Sm(III)-, Tb(III)-, Dy(III)- and Ho(III)-complexes have been analysed in the light of LSJ terms.

  12. Nitrato-complexes of Y(III), La(III), Ce(III), Pr(III), Nd(III), Sm(III), Gd(III), Tb(III), Dy(III) and Ho(III) with 2-(2'-pyridyl) benzimidazole

    International Nuclear Information System (INIS)

    Mishra, A.; Singh, M.P.; Singh, V.K.

    1982-01-01

    The nitrato-complexes, [Y(PyBzH) 2 (NO 3 ) 2 ]NO 3 .H 2 O and Nd, Sm, Gd, Tb, Dy, Ho ; n=1-3, m=0-0.5 ; PyBzh=2-(2 -pyridyl)benzimidazole] are formed on interaction of the ligand with metal nitrates in ethanol. The electrical conductance values (116-129 ohm -1 cm 2 mol -1 ) suggest 1:1 electrolyte-nature of the complexes. Magnetic moment values of Ce(2.53 B.M.), Pr(3.62 B.M.), Nd(3.52 B.M.), Sm(1.70 B.M.), Gd(8.06 B.M.), Tb(9.44 B.M.), Dy(10.56 B.M.) and Ho(10.51 B.M.) in the complexes confirm the terpositive state of the metals. Infrared evidences are obtained for the existance of both coordinated (C 2 v) and uncoordinated (D 3 h) nitrate groups. Electronic absorption spectra of Pr(III)-, Nd(III)-, Sm(III)-, Tb(III)-, Dy(III)- and Ho(III)-complexes have been analysed in the light of LSJ terms. (author)

  13. Method of electric powertrain matching for battery-powered electric cars

    Science.gov (United States)

    Ning, Guobao; Xiong, Lu; Zhang, Lijun; Yu, Zhuoping

    2013-05-01

    The current match method of electric powertrain still makes use of longitudinal dynamics, which can't realize maximum capacity for on-board energy storage unit and can't reach lowest equivalent fuel consumption as well. Another match method focuses on improving available space considering reasonable layout of vehicle to enlarge rated energy capacity for on-board energy storage unit, which can keep the longitudinal dynamics performance almost unchanged but can't reach lowest fuel consumption. Considering the characteristics of driving motor, method of electric powertrain matching utilizing conventional longitudinal dynamics for driving system and cut-and-try method for energy storage system is proposed for passenger cars converted from traditional ones. Through combining the utilization of vehicle space which contributes to the on-board energy amount, vehicle longitudinal performance requirements, vehicle equivalent fuel consumption level, passive safety requirements and maximum driving range requirement together, a comprehensive optimal match method of electric powertrain for battery-powered electric vehicle is raised. In simulation, the vehicle model and match method is built in Matlab/simulink, and the Environmental Protection Agency (EPA) Urban Dynamometer Driving Schedule (UDDS) is chosen as a test condition. The simulation results show that 2.62% of regenerative energy and 2% of energy storage efficiency are increased relative to the traditional method. The research conclusions provide theoretical and practical solutions for electric powertrain matching for modern battery-powered electric vehicles especially for those converted from traditional ones, and further enhance dynamics of electric vehicles.

  14. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    International Nuclear Information System (INIS)

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D.; Chmurzynski, L.

    2008-01-01

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement

  15. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland); Chmurzynski, L. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland)], E-mail: lech@chem.univ.gda.pl

    2008-08-15

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement.

  16. Electrical machining method of insulating ceramics

    International Nuclear Information System (INIS)

    Fukuzawa, Y.; Mohri, N.; Tani, T.

    1999-01-01

    This paper describes a new electrical discharge machining method for insulating ceramics using an assisting electrode with either a sinking electrical discharge machine or a wire electrical discharge machine. In this method, the metal sheet or mesh is attached to the ceramic surface as an assisting material for the discharge generation around the insulator surface. When the machining condition changes from the attached material to the workpiece, a cracked carbon layer is formed on the workpiece surface. As this layer has an electrical conductivity, electrical discharge occurs in working oil between the tool electrode and the surface of the workpiece. The carbon is formed from the working oil during this electrical discharge. Even after the material is machined, an electrical discharge occurs in the gap region between the tool electrode and the ceramic because an electrically conductive layer is generated continuously. Insulating ceramics can be machined by the electrical discharge machining method using the above mentioned surface modification phenomenon. In this paper the authors show a machined example demonstrating that the proposed method is available for machining a complex shape on insulating ceramics. Copyright (1999) AD-TECH - International Foundation for the Advancement of Technology Ltd

  17. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2006-03-07

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  18. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2008-09-02

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  19. Heat and electricity generating methods

    International Nuclear Information System (INIS)

    Buter, J.

    1977-01-01

    A short synopsis on the actual methods of heating of lodgings and of industrial heat generation is given. Electricity can be generated in steam cycles heated by burning of fossil fuels or by nuclear energy. A valuable contribution to the electricity economy is produced in the hydroelectric power plants. Besides these classical methods, also the different procedures of direct electricity generation are treated: thermoelectric, thermionic, magnetohydrodynamic power sources, solar and fuel cells. (orig.) [de

  20. Reply to the comment by B. Ghobadipour and B. Mojarradi "M. Abedi, S.A. Torabi, G.-H. Norouzi and M. Hamzeh; ELECTRE III: A knowledge-driven method for integration of geophysical data with geological and geochemical data in mineral prospectivity mapping"

    Science.gov (United States)

    Abedi, Maysam

    2015-06-01

    This reply discusses the results of two previously developed approaches in mineral prospectivity/potential mapping (MPM), i.e., ELECTRE III and PROMETHEE II as well-known methods in multi-criteria decision-making (MCDM) problems. Various geo-data sets are integrated to prepare MPM in which generated maps have acceptable matching with the drilled boreholes. Equal performance of the applied methods is indicated in the studied case. Complementary information of these methods is also provided in order to help interested readers to implement them in MPM process.

  1. Apparatuses and methods for generating electric fields

    Science.gov (United States)

    Scott, Jill R; McJunkin, Timothy R; Tremblay, Paul L

    2013-08-06

    Apparatuses and methods relating to generating an electric field are disclosed. An electric field generator may include a semiconductive material configured in a physical shape substantially different from a shape of an electric field to be generated thereby. The electric field is generated when a voltage drop exists across the semiconductive material. A method for generating an electric field may include applying a voltage to a shaped semiconductive material to generate a complex, substantially nonlinear electric field. The shape of the complex, substantially nonlinear electric field may be configured for directing charged particles to a desired location. Other apparatuses and methods are disclosed.

  2. Method for protecting an electric generator

    Science.gov (United States)

    Kuehnle, Barry W.; Roberts, Jeffrey B.; Folkers, Ralph W.

    2008-11-18

    A method for protecting an electrical generator which includes providing an electrical generator which is normally synchronously operated with an electrical power grid; providing a synchronizing signal from the electrical generator; establishing a reference signal; and electrically isolating the electrical generator from the electrical power grid if the synchronizing signal is not in phase with the reference signal.

  3. Une solution informatisée à l'analyse de sensibilité d'Electre 3

    Directory of Open Access Journals (Sweden)

    Ben-Mena S.

    2001-01-01

    Full Text Available A computerized solution to the sensitivity analysis of Electre 3. The multicriteria method Electre III allows sorting out actions likely to solve a decision problem, basing one arguments on several criteria. The complexity of the method renders a possible sensitivity analysis tedious. This short communication details an iterative algorithm used in the pre-existing Electre III software which allows carrying out this analysis automatically.

  4. [Orthogonal design method to optimize rehabilitation prescription of pulsed electric field at Jiaji (EX-B 2) points for spinal cord injury].

    Science.gov (United States)

    Zhang, Lifeng; Zhang, Hui; Wang, Lin; Liu, Yanyan; Sun, Xianyue; Li, Lingyan; Hou, Jing

    2015-01-01

    By using orthogonal design method to optimnize prescription of pulsed electric field at Jiaji (EX- B 2) points for spinal cord injury (SCI). Fifty six patients of SCI were selected, in which 36 cases were divided into orthogonal design trial and 20 cases were into clinical verification. With 36 patients who received orthogonal design trial, Frankel grading scale was used as observation index to screen optimal prescription of pulsed electric field. Pulse frequency (factor A) included low frequency (factor A(I), 10(2) Hz). moderate frequency (factor A(II), 10(4) Hz) and high frequency (factor A(III), 10(3) Hz); pulse amplitude (factor B) included 0-30 V (factor B ), 0-60 V (factor B(II)) and 0-90 V (factor B(III)); pulse width (factor C) included 0.1 ms (factor C(I)). 0.6 ms (factor C(II)) and 0.9 ms (factor C(III)); acupuncture time (factor D) included one month (DI), three months (D(II)) and five months (D(III)). Twenty patients were used for clinical efficacy observation and the effects of screened optimal pre scription of pulsed electric field at Jiaji (EX-B 2) points combined with regular rehabilitation training on spasm se- verity, score of sensory and motor functions, Barthel index and Frankel score were observed. (1) As results of orthogonal design trial, the optimal prescription was A(III) B(III), C(I), D(III), which were high frequency (10(3) Hz), 0-90 V of pulse amplitude, 0.4 ms of pulse width and 5 months of treatment time. (2) As results of 20 patient clinical verification, Ashworth score, tendon reflex and clonus were all significantly improved (Ppulsed electric field at Jiaji (EX-B 2) points for spinal cord injury is high frequency (10& Hz), 0-90 V of pulse amplitude, 0.4 ms of pulse width and 5 months of treatment time. The optimal prescription of pulsed electric field at Jiaji (EX-B 2) points combined with regular rehabilitation could obviously improve spasm severity, enhance senso- ry and motor functions, and ameliorate activity of daily life and

  5. Synthesis, spectroscopic characterization, solid state d.c. electrical conductivity and biological studies of some lanthanide(III chloride complexes with a heterocyclic Schiff base ligand

    Directory of Open Access Journals (Sweden)

    K. Mohanan

    2016-07-01

    Full Text Available Condensation of 2-hydroxy-1-naphthaldehyde with 2-amino-3-carboxyethyl-4,5-dimethylthiophene in 1:1 molar ratio, yielded a potentially tridentate Schiff base viz. 2-[N-(2′-hydroxy-1-naphthylideneamino]-3-carboxyethyl-4,5-dimethylthiophene (HNAT. This ligand formed complexes with lanthanum(III, cerium(III, praseodymium(III, neodymium(III, samarium(III, europium(III and gadolinium(III chloride under well defined conditions. These complexes were characterized through elemental analysis, molar conductance, magnetic moment measurements, IR, UV–Vis, FAB mass and 1H NMR spectral studies. Analytical data showed that all the metal complexes exhibited 1:1 metal–ligand ratio. Molar conductance values adequately confirmed the non-electrolytic nature of the metal complexes. The proton NMR spectral observations supplement the IR spectral assignments. The spectral data revealed that the ligand acted as neutral tridentate, coordinating to the metal ion through azomethine nitrogen, ester carbonyl and naphtholate oxygen without deprotonation. The ligand and its lanthanum(III chloride complex were subjected to XRD studies. The lanthanum(III chloride complex has undergone a facile transesterification reaction. The solid state d.c. electrical conductivity of some selected complexes were measured as a function of temperature, indicating the semiconducting nature of the metal complexes. The antimicrobial activities were examined by disk diffusion method against some pathogenic bacterial and fungal species.

  6. Service quality benchmarking via a novel approach based on fuzzy ELECTRE III and IPA: an empirical case involving the Italian public healthcare context.

    Science.gov (United States)

    La Fata, Concetta Manuela; Lupo, Toni; Piazza, Tommaso

    2017-11-21

    A novel fuzzy-based approach which combines ELECTRE III along with the Importance-Performance Analysis (IPA) is proposed in the present work to comparatively evaluate the service quality in the public healthcare context. Specifically, ELECTRE III is firstly considered to compare the service performance of examined hospitals in a noncompensatory manner. Afterwards, IPA is employed to support the service quality management to point out improvement needs and their priorities. The proposed approach also incorporates features of the Fuzzy Set Theory so as to address the possible uncertainty, subjectivity and vagueness of involved experts in evaluating the service quality. The model is applied to five major Sicilian public hospitals, and strengths and criticalities of the delivered service are finally highlighted and discussed. Although several approaches combining multi-criteria methods have already been proposed in the literature to evaluate the service performance in the healthcare field, to the best of the authors' knowledge the present work represents the first attempt at comparing service performance of alternatives in a noncompensatory manner in the investigated context.

  7. Methods for enhancing P-type doping in III-V semiconductor films

    Science.gov (United States)

    Liu, Feng; Stringfellow, Gerald; Zhu, Junyi

    2017-08-01

    Methods of doping a semiconductor film are provided. The methods comprise epitaxially growing the III-V semiconductor film in the presence of a dopant, a surfactant capable of acting as an electron reservoir, and hydrogen, under conditions that promote the formation of a III-V semiconductor film doped with the p-type dopant. In some embodiments of the methods, the epitaxial growth of the doped III-V semiconductor film is initiated at a first hydrogen partial pressure which is increased to a second hydrogen partial pressure during the epitaxial growth process.

  8. Electrical estimating methods

    CERN Document Server

    Del Pico, Wayne J

    2014-01-01

    Simplify the estimating process with the latest data, materials, and practices Electrical Estimating Methods, Fourth Edition is a comprehensive guide to estimating electrical costs, with data provided by leading construction database RS Means. The book covers the materials and processes encountered by the modern contractor, and provides all the information professionals need to make the most precise estimate. The fourth edition has been updated to reflect the changing materials, techniques, and practices in the field, and provides the most recent Means cost data available. The complexity of el

  9. Level III Reliability methods feasible for complex structures

    NARCIS (Netherlands)

    Waarts, P.H.; Boer, A. de

    2001-01-01

    The paper describes the comparison between three types of reliability methods: code type level I used by a designer, full level I and a level III method. Two cases that are typical for civil engineering practise, a cable-stayed subjected to traffic load and the installation of a soil retaining sheet

  10. Methods for improved growth of group III nitride buffer layers

    Science.gov (United States)

    Melnik, Yurity; Chen, Lu; Kojiri, Hidehiro

    2014-07-15

    Methods are disclosed for growing high crystal quality group III-nitride epitaxial layers with advanced multiple buffer layer techniques. In an embodiment, a method includes forming group III-nitride buffer layers that contain aluminum on suitable substrate in a processing chamber of a hydride vapor phase epitaxy processing system. A hydrogen halide or halogen gas is flowing into the growth zone during deposition of buffer layers to suppress homogeneous particle formation. Some combinations of low temperature buffers that contain aluminum (e.g., AlN, AlGaN) and high temperature buffers that contain aluminum (e.g., AlN, AlGaN) may be used to improve crystal quality and morphology of subsequently grown group III-nitride epitaxial layers. The buffer may be deposited on the substrate, or on the surface of another buffer. The additional buffer layers may be added as interlayers in group III-nitride layers (e.g., GaN, AlGaN, AlN).

  11. Electrical energy consumption control apparatuses and electrical energy consumption control methods

    Science.gov (United States)

    Hammerstrom, Donald J.

    2012-09-04

    Electrical energy consumption control apparatuses and electrical energy consumption control methods are described. According to one aspect, an electrical energy consumption control apparatus includes processing circuitry configured to receive a signal which is indicative of current of electrical energy which is consumed by a plurality of loads at a site, to compare the signal which is indicative of current of electrical energy which is consumed by the plurality of loads at the site with a desired substantially sinusoidal waveform of current of electrical energy which is received at the site from an electrical power system, and to use the comparison to control an amount of the electrical energy which is consumed by at least one of the loads of the site.

  12. Electrically driven hybrid Si/III-V Fabry-Pérot lasers based on adiabatic mode transformers.

    Science.gov (United States)

    Ben Bakir, B; Descos, A; Olivier, N; Bordel, D; Grosse, P; Augendre, E; Fulbert, L; Fedeli, J M

    2011-05-23

    We report the first demonstration of an electrically driven hybrid silicon/III-V laser based on adiabatic mode transformers. The hybrid structure is formed by two vertically superimposed waveguides separated by a 100-nm-thick SiO2 layer. The top waveguide, fabricated in an InP/InGaAsP-based heterostructure, serves to provide optical gain. The bottom Si-waveguides system, which supports all optical functions, is constituted by two tapered rib-waveguides (mode transformers), two distributed Bragg reflectors (DBRs) and a surface-grating coupler. The supermodes of this hybrid structure are controlled by an appropriate design of the tapers located at the edges of the gain region. In the middle part of the device almost all the field resides in the III-V waveguide so that the optical mode experiences maximal gain, while in regions near the III-V facets, mode transformers ensure an efficient transfer of the power flow towards Si-waveguides. The investigated device operates under quasi-continuous wave regime. The room temperature threshold current is 100 mA, the side-mode suppression ratio is as high as 20 dB, and the fiber-coupled output power is ~7 mW.

  13. Spectrophotometric and pH-Metric Studies of Ce(III, Dy(III, Gd(III,Yb(III and Pr(III Metal Complexes with Rifampicin

    Directory of Open Access Journals (Sweden)

    A. N. Sonar

    2011-01-01

    Full Text Available The metal-ligand and proton-ligand stability constant of Ce(III, Dy(III, Gd(III,Yb(III and Pr(III metals with substituted heterocyclic drug (Rifampicin were determined at various ionic strength by pH metric titration. NaClO4 was used to maintain ionic strength of solution. The results obtained were extrapolated to the zero ionic strength using an equation with one individual parameter. The thermodynamic stability constant of the complexes were also calculated. The formation of complexes has been studied by Job’s method. The results obtained were of stability constants by pH metric method is confirmed by Job’s method.

  14. Electrical Methods: Resistivity Methods

    Science.gov (United States)

    Surface electrical resistivity surveying is based on the principle that the distribution of electrical potential in the ground around a current-carrying electrode depends on the electrical resistivities and distribution of the surrounding soils and rocks.

  15. Electricity/electronics in electric-powered vehicles and electric management III; Elektrik/Elektronik in Hybrid- und Elektrofahrzeugen und elektrisches Energiemanagement III

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, Carsten; Sirch, Ottmar

    2012-07-01

    The concept of e-Mobility currently is on everyone's lips. Worldwide, manufacturers and suppliers work with high pressure on new concepts and vehicles. Hybrid vehicles pave the way for pure electric-powered vehicles. Due to the problems of energy saving, electric-powered vehicles will take a long time for an extensively utilization. In the book underconsideration, experts from research and practice report on the latest technologies.

  16. A CALCULATION METHOD OF TRANSIENT MODES OF ELECTRIC SHIPS’ PROPELLING ELECTRIC PLANTS

    Directory of Open Access Journals (Sweden)

    V. A. Yarovenko

    2017-12-01

    Full Text Available The purpose of the work is to develop the method for calculating the transient modes of electric ships’ propelling electric plants during maneuver. This will allow us to evaluate and improve the maneuverability of vessels with electric motion. Methodology. The solution to the problems is proposed to be carried out on the basis of mathematical modeling of maneuvering modes. The duration of transient modes in an electric power plant at electric ships’ maneuvers is commensurable with the transient operation modes of the vessel itself. Therefore, the analysis of the electric power plants’ maneuvering modes should be made in unity with all the components of the ship’s propulsion complex. Results. A specified mathematical model of transient regimes of electric ship’s propulsion complex, including thermal motors, synchronous generators, electric power converters, propulsion motors, propellers, rudder, ship’s hull is developed. The model is universal. It covers the vast majority of modern and promising electric ships with a traditional type of propulsors. It allows calculating the current values of the basic mode indicators and assessing the quality indicators of maneuvering. The model is made in relative units. Dimensionless parameters of the complex are obtained. These parameters influence the main indicators of the quality of maneuvering. The adequacy of the suggested specified mathematical model and the developed computation method based on it were confirmed. To do this, the results of mathematical modeling for a real electric ship were compared with the data obtained in the course of field experiments conducted by other researchers. Originality. The mathematical description of a generator unit, as an integral part of an indivisible ship’s propulsion complex, makes it possible to calculate the dynamic operation modes of electric power sources during electric vessels’ maneuvering. There is an opportunity to design the electric ships

  17. Thorium coprecipitation method for spectrophotometric determination of arsenic (III) and arsenic (V) in groundwaters

    International Nuclear Information System (INIS)

    Tamari, Yuzo; Yamamoto, Nobuki; Tsuji, Haruo; Kusaka, Yuzuru

    1989-01-01

    A new coprecipitation method for the spectrophotometry of arsenic (III) and arsenic (V) in groundwater has been developed. Arsenic (III) and arsenic (V) were coprecipitated with thorium (IV) hydroxide from 1000ml of groundwater at pH9. The precipitate was centrifuged and then dissolved with hydrochloric acid. Arsenic (III) was spectrophotometrically determined by the usual silver diethylditiocarbamate (Ag-DDTC) method after generating the arsenic to arsine with sodium tetrahydroborate under masking the thorium with EDTA-NaF at pH6. From another portion of the same groundwater, both arsenic (III) and arsenic (V) were determined by the Ag-DDTC method after reducing all the arsenic to arsine with sodium tetrahydroborate at pH less than 1 in the presence of the EDTA-NaF. The concentration of arsenic (V) was obtained by subtracting that of arsenic (III) from the total for arsenic. (author)

  18. Polypyrrole–titanium(IV) doped iron(III) oxide nanocomposites: Synthesis, characterization with tunable electrical and electrochemical properties

    International Nuclear Information System (INIS)

    Nandi, Debabrata; Ghosh, Arup Kumar; Gupta, Kaushik; De, Amitabha; Sen, Pintu; Duttachowdhury, Ankan; Ghosh, Uday Chand

    2012-01-01

    Highlights: ► Synthesis and characterization of polymer nanocomposite based on titanium doped iron(III) oxide. ► Electrical conductivity increased 100 times in composite with respect to polymer. ► Electrochemical capacitance of polymer composites increased with nanooxide content. ► Thermal stability of the polymer enhanced with nano oxide content. -- Abstract: Titanium(IV)-doped synthetic nanostructured iron(III) oxide (NITO) and polypyrrole (PPy) nanocomposites was fabricated by in situ polymerization using FeCl 3 as initiator. The polymer nanocomposites (PNCs) and pure NITO were characterized by X-ray diffraction, Föurier transform infrared spectroscopy, scanning electron microscopy, electron dispersive X-ray spectroscopy, transmission electron microscopy, etc. Thermo gravimetric and differential thermal analyses showed the enhancement of thermal stability of PNCs than the pure polymer. Electrical conductivity of the PNCs had increased significantly from 0.793 × 10 −2 S/cm to 0.450 S/cm with respect to the PPy, and that had been explained by 3-dimensional variable range hopping (VRH) conduction mechanisms. In addition, the specific capacitance of PNCs had increased from 147 F/g to 176 F/g with increasing NITO content than that of pure NITO (26 F/g), presumably due to the growing of mesoporous structure with increasing NITO content in PNCs which reduced the charge transfer resistance significantly.

  19. Application of sorption method on hydroxides for purification of some reactive from iron(III) markings

    International Nuclear Information System (INIS)

    Rakhmonberdiev, A.D.; Khamidov, B.O.

    1986-01-01

    The method of purification of solutions of citric acid, tartaric acid and their salts, potassium hydroxide, potassium nitrate and chloride, sodium perchlorate from iron (III) impurities by means of sorption method on zirconium hydroxide is elaborated. The control of iron(III) content in solutions is conducted by inversion voltammetry method with mercury-graphite electrode. It is defined that complete sorption of iron (III) ions achieves at ph =4÷14.

  20. Localización empresarial en Aragón: una aplicación empírica de la ayuda a la decisión multicriterio tipo ELECTRE I y III. Robustez de los resultados obtenidos = Industrial Location Decisions in Aragon: an Empirical Application of a Multi-criterion Methodology of Aid to the Decision using ELECTRE Methods I and III. Robustness of the Obtained Results

    Directory of Open Access Journals (Sweden)

    García Cebrián, Lucía Isabel

    2009-01-01

    Full Text Available La decisión de la localización es una de las opciones estratégicas más importantes que tienen que tomar las empresas, con influencia directa sobre su competitividad. Por este motivo, se han desarrollado numerosas metodologías que ayudan en la toma de estas decisiones. En este trabajo, se realiza una aplicación empírica de una metodología de ayuda a la decisión multicriterio; específicamente, se ha optado por el método ELECTRE en sus versiones I y III, con el fin de seleccionar el mejor emplazamiento para una empresa. Para esta aplicación, se utilizan como alternativas de localización las Comarcas de Aragón, como factores de localización se utilizan 8 criterios y como peso o importancia de esos factores los obtenidos mediante una encuesta. Además, se aporta evidencia sobre la consistencia de los resultados obtenidos. Como se aprecia en el trabajo, aunque la tipología de los problemas a los que van destinados ambos métodos son distintos, los resultados obtenidos pueden ser considerados como consistentes. = The location decision is one of the most important strategic decisions that have to take the firms, with direct influence on their competitiveness. For this reason, many methodologies have been developed to help in the decision making. In this paper, we make an empirical application of a multi-criterion methodology of aid to the decision; specifically, ELECTRE method has been chosen in its versions I and III, in order to select the best place for a firm. The alternatives are counties in Aragon (Spain, and we use eight criteria. The weight has been obtained by surveys. In addition, evidence is contributed about the consistency of the obtained results. Though the typology of the problems to which both methods are destined are different, the obtained results can be considered consistent.

  1. A Review of Design Optimization Methods for Electrical Machines

    Directory of Open Access Journals (Sweden)

    Gang Lei

    2017-11-01

    Full Text Available Electrical machines are the hearts of many appliances, industrial equipment and systems. In the context of global sustainability, they must fulfill various requirements, not only physically and technologically but also environmentally. Therefore, their design optimization process becomes more and more complex as more engineering disciplines/domains and constraints are involved, such as electromagnetics, structural mechanics and heat transfer. This paper aims to present a review of the design optimization methods for electrical machines, including design analysis methods and models, optimization models, algorithms and methods/strategies. Several efficient optimization methods/strategies are highlighted with comments, including surrogate-model based and multi-level optimization methods. In addition, two promising and challenging topics in both academic and industrial communities are discussed, and two novel optimization methods are introduced for advanced design optimization of electrical machines. First, a system-level design optimization method is introduced for the development of advanced electric drive systems. Second, a robust design optimization method based on the design for six-sigma technique is introduced for high-quality manufacturing of electrical machines in production. Meanwhile, a proposal is presented for the development of a robust design optimization service based on industrial big data and cloud computing services. Finally, five future directions are proposed, including smart design optimization method for future intelligent design and production of electrical machines.

  2. Boundary element methods for electrical engineers

    CERN Document Server

    POLJAK, D

    2005-01-01

    In the last couple of decades the Boundary Element Method (BEM) has become a well-established technique that is widely used for solving various problems in electrical engineering and electromagnetics. Although there are many excellent research papers published in the relevant literature that describe various BEM applications in electrical engineering and electromagnetics, there has been a lack of suitable textbooks and monographs on the subject. This book presents BEM in a simple fashion in order to help the beginner to understand the very basic principles of the method. It initially derives B

  3. Methods of developing an emission cataster for low frequency electric and magnetic fields

    International Nuclear Information System (INIS)

    Stenzel, E.; Frohn, O.; Koffke, K.; Dunker, J.; Plotzke, O.

    1996-01-01

    In the common environment each individual is exposed to a large variety of power frequency or extremely low frequency (EFL) electric and magnetic fields. Traditionally these fields have been thought to be harmless but recent scientific studies reveal, however, that at least effects do exists. Therefore father investigations have to be carried out in order to obtain a greater data base. As a major point new ways have to be established that allow an effective collection of an relevant data concerning the exposition m this fields. In our contribution for the first time methods that consider simultaneously an major field emittants in the ramp of 0-500 Hz spread over the area as great as a town district. These methods have been developed and successfully tested in the district Buch/Karow of Berlin during the research study 'emission cataster of electric and magnetic field exposure in Berlin -a comparative study in selected public areas'. In this study the following field sources have been taken to consideration: i) 110-kV, 220-kV, 380-kV transmission lines, ii) 110-kV power transmission cables, iii) relay station Karow, iv) 10-kV medium voltage level, v) 1-kV distribution level, vi) power stations, vii) railway, viii) urban railway. (author)

  4. Battery charging control methods, electric vehicle charging methods, battery charging apparatuses and rechargeable battery systems

    Science.gov (United States)

    Tuffner, Francis K [Richland, WA; Kintner-Meyer, Michael C. W. [Richland, WA; Hammerstrom, Donald J [West Richland, WA; Pratt, Richard M [Richland, WA

    2012-05-22

    Battery charging control methods, electric vehicle charging methods, battery charging apparatuses and rechargeable battery systems. According to one aspect, a battery charging control method includes accessing information regarding a presence of at least one of a surplus and a deficiency of electrical energy upon an electrical power distribution system at a plurality of different moments in time, and using the information, controlling an adjustment of an amount of the electrical energy provided from the electrical power distribution system to a rechargeable battery to charge the rechargeable battery.

  5. Spectrophotometric method of the determination of gold (III) by using imipramine hydrochloride and promethazine hydrochloride

    International Nuclear Information System (INIS)

    Dembinski, B.; Kurzawa, M.; Szydlowska-Czerniak, A.

    2003-01-01

    Imipramine hydrochloride (IPM.HCl) and promethazine hydrochloride (PMT-HCl) were used for the spectrophotometric determination of gold (III) in the aqueous solution. The halides complexes of gold (III) created a coloured coupling with the studied drugs which were extractable in chloroform. These new compounds were characterized by IR,UV-VIS spectra and thermal and elemental analysis. Rapid and sensitive spectrophotometric method for the determination of gold (III) in the aqueous solution is described. The absorbance was found to be linear function of the gold (III) concentration in the range from 0.2 to 20 x10/sup -1/ mg. The ratio of complex (AuX/sub 4/) to the organic cation from drug in the obtained compounds was determined as 1:1. The method was satisfactorily applied to the analysis of gold (III). A great advantage of the proposed method is that the trace amounts of gold (III) can also be examined. (author)

  6. Electrical condition monitoring method for polymers

    Science.gov (United States)

    Watkins, Jr. Kenneth S.; Morris, Shelby J.; Masakowski, Daniel D.; Wong, Ching Ping; Luo, Shijian

    2010-02-16

    An electrical condition monitoring method utilizes measurement of electrical resistivity of a conductive composite degradation sensor to monitor environmentally induced degradation of a polymeric product such as insulated wire and cable. The degradation sensor comprises a polymeric matrix and conductive filler. The polymeric matrix may be a polymer used in the product, or it may be a polymer with degradation properties similar to that of a polymer used in the product. The method comprises a means for communicating the resistivity to a measuring instrument and a means to correlate resistivity of the degradation sensor with environmentally induced degradation of the product.

  7. Method for hermetic electrical connections

    Science.gov (United States)

    Monroe, Saundra L [Tijeras, NM; Glass, S Jill [Albuquerque, NM; Stone, Ronnie G [Albuquerque, NM; Bond, Jamey T [Albuquerque, NM; Susan, Donald F [Albuquerque, NM

    2011-12-27

    A method of providing a hermetic, electrical connection between two electrical components by mating at least one metal pin in a glass-ceramic to metal seal connector to two electrical components, wherein the glass-ceramic to metal seal connector incorporates at least one metal pin encased (sealed) in a glass-ceramic material inside of a metal housing, with the glass-ceramic material made from 65-80% SiO.sub.2, 8-16% Li.sub.2O, 2-8% Al.sub.2O.sub.3, 1-5% P.sub.2O.sub.5, 1-8% K.sub.2O, 0.5-7% B.sub.2O.sub.3, and 0-5% ZnO. The connector retains hermeticity at temperatures as high as 700.degree. C. and pressures as high as 500 psi.

  8. Asynchronous decentralized method for interconnected electricity markets

    International Nuclear Information System (INIS)

    Huang, Anni; Joo, Sung-Kwan; Song, Kyung-Bin; Kim, Jin-Ho; Lee, Kisung

    2008-01-01

    This paper presents an asynchronous decentralized method to solve the optimization problem of interconnected electricity markets. The proposed method decomposes the optimization problem of combined electricity markets into individual optimization problems. The impact of neighboring markets' information is included in the objective function of the individual market optimization problem by the standard Lagrangian relaxation method. Most decentralized optimization methods use synchronous models of communication to exchange updated market information among markets during the iterative process. In this paper, however, the solutions of the individual optimization problems are coordinated through an asynchronous communication model until they converge to the global optimal solution of combined markets. Numerical examples are presented to demonstrate the advantages of the proposed asynchronous method over the existing synchronous methods. (author)

  9. Mechanic-electrical transformations in the Kelvin method

    Energy Technology Data Exchange (ETDEWEB)

    Zharkikh, Yu. S., E-mail: yurzhar@gmail.com [Faculty of Radio Physics, Electronics and Computer Systems, Taras Shevchenko National University of Kyiv, 4G, Ave. Academician Glushkov, 03127, Kyiv (Ukraine); Lysochenko, S.V., E-mail: lys@univ.kiev.ua [Institute of High Technologies, Taras Shevchenko National University of Kyiv, 4G, Ave. Academician Glushkov, 03127, Kyiv (Ukraine)

    2017-04-01

    Highlights: • Used in Kelvin method dynamic capacitor is a mechanic-electrical transformer. • The oscillations of its plate are source of extraneous forces which cause the appearance of an electric current. • The signal is caused not by the contact potential difference, but by oscillation in the screening conditions of charge in the dynamic capacitor gap. • Combining the Kelvin method with electron emission methods to determine the work function may lead to incorrectness. - Abstract: To explain the initiation mechanism of alternating current in an electric circuit containing the dynamic capacitor a model of mechanic- electrical transformation is suggested to use. In such a model, electric charges disposed between the capacitor plates serve as a cause of measured signal in contrast to the contact potential difference, which is considered as the main base in the Kelvin’s model. If one of the plates moves periodically, then the conditions of the charges screening are changed and thereby the capacitor recharging current is arise. The measuring is based on compensation of the recharging current by current, which generated by a source of electromotive force (EMF). The compensation voltage depends on both the distribution of ions or dipoles over the studied surface and the charges creating the surface potential barrier. This voltage is independent on the bulk electro-physical characteristics of a solid.

  10. Drafting method of electricity and electron design

    International Nuclear Information System (INIS)

    Gungbon, Junchun

    1989-11-01

    This book concentrates on drafting of electricity and electron design. It deals with The meaning of electricity and electron drafting JIS standard regulation the types of drafting and line and letter, basics drafting with projection drafting method, plan projection and development elevation, Drafting method of shop drawing, practical method of design and drafting, Design and drafting of technic and illustration, Connection diagram, Drafting of wiring diagram for light and illumination, Drafting of development connection diagram for sequence control, Drafting of logic circuit sign of flow chart and manual, drafting for a electron circuit diagram and Drawing of PC board.

  11. Thermal Modeling Method Improvements for SAGE III on ISS

    Science.gov (United States)

    Liles, Kaitlin; Amundsen, Ruth; Davis, Warren; McLeod, Shawn

    2015-01-01

    The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument is the fifth in a series of instruments developed for monitoring aerosols and gaseous constituents in the stratosphere and troposphere. SAGE III will be delivered to the International Space Station (ISS) via the SpaceX Dragon vehicle. A detailed thermal model of the SAGE III payload, which consists of multiple subsystems, has been developed in Thermal Desktop (TD). Many innovative analysis methods have been used in developing this model; these will be described in the paper. This paper builds on a paper presented at TFAWS 2013, which described some of the initial developments of efficient methods for SAGE III. The current paper describes additional improvements that have been made since that time. To expedite the correlation of the model to thermal vacuum (TVAC) testing, the chambers and GSE for both TVAC chambers at Langley used to test the payload were incorporated within the thermal model. This allowed the runs of TVAC predictions and correlations to be run within the flight model, thus eliminating the need for separate models for TVAC. In one TVAC test, radiant lamps were used which necessitated shooting rays from the lamps, and running in both solar and IR wavebands. A new Dragon model was incorporated which entailed a change in orientation; that change was made using an assembly, so that any potential additional new Dragon orbits could be added in the future without modification of the model. The Earth orbit parameters such as albedo and Earth infrared flux were incorporated as time-varying values that change over the course of the orbit; despite being required in one of the ISS documents, this had not been done before by any previous payload. All parameters such as initial temperature, heater voltage, and location of the payload are defined based on the case definition. For one component, testing was performed in both air and vacuum; incorporating the air convection in a submodel that was

  12. An analytical optimization method for electric propulsion orbit transfer vehicles

    International Nuclear Information System (INIS)

    Oleson, S.R.

    1993-01-01

    Due to electric propulsion's inherent propellant mass savings over chemical propulsion, electric propulsion orbit transfer vehicles (EPOTVs) are a highly efficient mode of orbit transfer. When selecting an electric propulsion device (ion, MPD, or arcjet) and propellant for a particular mission, it is preferable to use quick, analytical system optimization methods instead of time intensive numerical integration methods. It is also of interest to determine each thruster's optimal operating characteristics for a specific mission. Analytical expressions are derived which determine the optimal specific impulse (Isp) for each type of electric thruster to maximize payload fraction for a desired thrusting time. These expressions take into account the variation of thruster efficiency with specific impulse. Verification of the method is made with representative electric propulsion values on a LEO-to-GEO mission. Application of the method to specific missions is discussed

  13. Load management in electrical networks. Objectives, methods, prospects

    International Nuclear Information System (INIS)

    Gabioud, D.

    2008-01-01

    This illustrated article takes up the problems related to the variation of the load in electricity networks. How to handle the peak load? Different solutions in the energy demand management are discussed. Method based on the price, method based on the reduction of the load by electric utilities. Information systems are presented which gives the consumer the needed data to participate in the local load management.

  14. Synthesis and physicochemical analysis of Sm (II, III) acetylacetone chelate complexes

    International Nuclear Information System (INIS)

    Kostyuk, N.N.; Dik, T.A.; Trebnikov, A.G.

    2004-01-01

    Sm (II, III) acetylacetone chelate complexes were synthesized by electrochemical method. It was shown that anode dissolution of the metal samarium over acetylacetone leads to formation of the Sm (II, III) chelate complexes: xSm(acac)2 · ySm(acac)3 · zH(acac). Factors x, y and z depend on quantity of the electricity, which flew through the electrolysis cell. The compositions of the obtained substances were confirmed by the physicochemical analysis (ultimate analysis, IR-, mass spectroscopy and thermal analysis (thermogravimetric, isothermal warming-up and differential scanning colorimetry). (Authors)

  15. Research on the Applicable Method of Valuation of Pure Electric Used vehicles

    Science.gov (United States)

    Cai, yun; Tan, zhengping; Wang, yidong; Mao, pan

    2018-03-01

    With the rapid growth in the ownership of pure electric vehicles, the research on the valuation of used electric vehicles has become the key to the development of the pure electric used vehicle market. The paper analyzed the application of the three value assessment methods, current market price method, capitalized earning method and replacement cost method, in pure electric used vehicles, and draws a conclusion that the replacement cost method is more suitable for pure electric used car. At the same time, the article also conducted a parametric correction exploration research, aiming at the characteristics of pure electric vehicles and replacement cost of the constituent factors. Through the analysis of the applicability parameters of physical devaluation, functional devaluation and economic devaluation, the revised replacement cost method can be used for the valuation of purely used electric vehicles for private use.

  16. A Rapid Synthetic Method for the Preparation of Two Tris-Cobalt(III) Compounds.

    Science.gov (United States)

    Jackman, Donald C.; Rillema, D. Paul

    1989-01-01

    Reports a method of preparation for tris(ethylenediamine)cobalt(III) and tris(2,2'-bipyridine)cobalt(III) that will shorten the preparation time by approximately 3 hours. Notes the time for synthesis and isolation of compound one was 1 hour (yield 38 percent) while compound two took 50 minutes (yield 71%). (MVL)

  17. Efficient forced vibration reanalysis method for rotating electric machines

    Science.gov (United States)

    Saito, Akira; Suzuki, Hiromitsu; Kuroishi, Masakatsu; Nakai, Hideo

    2015-01-01

    Rotating electric machines are subject to forced vibration by magnetic force excitation with wide-band frequency spectrum that are dependent on the operating conditions. Therefore, when designing the electric machines, it is inevitable to compute the vibration response of the machines at various operating conditions efficiently and accurately. This paper presents an efficient frequency-domain vibration analysis method for the electric machines. The method enables the efficient re-analysis of the vibration response of electric machines at various operating conditions without the necessity to re-compute the harmonic response by finite element analyses. Theoretical background of the proposed method is provided, which is based on the modal reduction of the magnetic force excitation by a set of amplitude-modulated standing-waves. The method is applied to the forced response vibration of the interior permanent magnet motor at a fixed operating condition. The results computed by the proposed method agree very well with those computed by the conventional harmonic response analysis by the FEA. The proposed method is then applied to the spin-up test condition to demonstrate its applicability to various operating conditions. It is observed that the proposed method can successfully be applied to the spin-up test conditions, and the measured dominant frequency peaks in the frequency response can be well captured by the proposed approach.

  18. An electrical method for the measurement of the thermal and electrical conductivity of reduced graphene oxide nanostructures.

    Science.gov (United States)

    Schwamb, Timo; Burg, Brian R; Schirmer, Niklas C; Poulikakos, Dimos

    2009-10-07

    This paper introduces an electrical four-point measurement method enabling thermal and electrical conductivity measurements of nanoscale materials. The method was applied to determine the thermal and electrical conductivity of reduced graphene oxide flakes. The dielectrophoretically deposited samples exhibited thermal conductivities in the range of 0.14-2.87 W m(-1) K(-1) and electrical conductivities in the range of 6.2 x 10(2)-6.2 x 10(3) Omega(-1) m(-1). The measured properties of each flake were found to be dependent on the duration of the thermal reduction and are in this sense controllable.

  19. PHASE GRADIENT METHOD OF MAGNETIC FIELD MEASUREMENTS IN ELECTRIC VEHICLES

    Directory of Open Access Journals (Sweden)

    N. G. Ptitsyna

    2013-01-01

    Full Text Available Operation of electric and hybrid vehicles demands real time magnetic field control, for instance, for fire and electromagnetic safety. The article deals with a method of magnetic field measurements onboard electric cars taking into account peculiar features of these fields. The method is based on differential methods of measurements, and minimizes the quantity of magnetic sensors.

  20. A Method of Evaluating Operation of Electric Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  1. Sensitive method for precise measurement of endogenous angiotensins I, II and III in human plasma

    International Nuclear Information System (INIS)

    Kawamura, M.; Yoshida, K.; Akabane, S.

    1987-01-01

    We measured endogenous angiotensins (ANGs) I, IIandIII using a system of extraction by Sep-Pak column followed by high performance liquid chromatography (HPLC) combined with radioimmunoassay (RIA). An excellent separation of ANGs was obtained by HPLC. The recovery of ANGs I, IIandIII was 80-84%, when these authentic peptides were added to 6 ml of plasma. The coefficient of variation of the ANGs was 0.04-0.09 for intra-assay and 0.08-0.13 for inter-assay, thereby indicating a good reproducibility. Plasma ANGs I, IIandIII measured by this method in 5 normal volunteers were 51,4.5 and 1.2 pg/ml. In the presence of captopril, ANGs IIandIII decreased by 84% and 77%, respectively, while ANG I increased 5.1 times. This method is therefore useful to assess the precise levels of plasma ANGs

  2. Analysis methods of stochastic transient electro–magnetic processes in electric traction system

    Directory of Open Access Journals (Sweden)

    T. M. Mishchenko

    2013-04-01

    Full Text Available Purpose. The essence and basic characteristics of calculation methods of transient electromagnetic processes in the elements and devices of non–linear dynamic electric traction systems taking into account the stochastic changes of voltages and currents in traction networks of power supply subsystem and power circuits of electric rolling stock are developed. Methodology. Classical methods and the methods of non–linear electric engineering, as well as probability theory method, especially the methods of stationary ergodic and non–stationary stochastic processes application are used in the research. Findings. Using the above-mentioned methods an equivalent circuit and the system of nonlinear integra–differential equations for electromagnetic condition of the double–track inter-substation zone of alternating current electric traction system are drawn up. Calculations allow obtaining electric traction current distribution in the areas of feeder zones. Originality. First of all the paper is interesting and important from scientific point of view due to the methods, which allow taking into account probabilistic character of change for traction voltages and electric traction system currents. On the second hand the researches develop the most efficient methods of nonlinear circuits’ analysis. Practical value. The practical value of the research is presented in application of the methods to the analysis of electromagnetic and electric energy processes in the traction power supply system in the case of high-speed train traffic.

  3. Systems and methods for producing electrical discharges in compositions

    KAUST Repository

    Cha, Min; Zhang, Xuming; Chung, Suk-Ho

    2015-01-01

    Systems and methods configured to produce electrical discharges in compositions, such as those, for example, configured to produce electrical discharges in compositions that comprise mixtures of materials, such as a mixture of a material having a

  4. Financial methods in competitive electricity markets

    Science.gov (United States)

    Deng, Shijie

    pricing electricity financial instruments such as electricity forwards, options and cross-commodity derivatives. It is also essential for the analysis of financial risk management, asset valuation, and project financing. In the setting of diffusion processes with multiple types of jumps, I examine three mean-reversion models for modeling the electricity spot prices. I impose some structure on the coefficients of the diffusion processes, which allows me to easily compute the prices of contingent claims (or, financial instruments) on electricity by Fourier methods. I derive the pricing formulas for various electricity derivatives and examine how the prices vary with different modeling assumptions. I demonstrate a couple of risk management applications of the electricity financial instruments. I also construct a real options approach to value electric power generation and transmission assets both with and without accounting for the operating characteristics of the assets. The implications of the mean-reversion jump-diffusion models on financial risk management and real asset valuation in competitive electricity markets are illustrated. With a discrete trinomial lattice modeling the underlying commodity prices, I estimate the effects of operational characteristics on the asset valuation by means of numerical examples that incorporate these aspects using stochastic dynamic programming. (Abstract shortened by UMI.)

  5. Current exposure method for CCP’s under Basel III

    Directory of Open Access Journals (Sweden)

    Antonie Kotzé

    2013-04-01

    Full Text Available Exposure-at-default is one of the most interesting and most difficult parameters to estimate in counterparty credit risk. Basel I offered only the non-internal Current Exposure Method for estimating this quantity whilst Basel II further introduced the Standardized Method and an Internal Model Method. Under new Basel III rules a central counterparty is defined as being a financial institution. New principles set out by the Basel Committee on Banking Supervision forces Central Counterparties in using the Current Exposure Method when estimating the credit exposures to Clearing Member banks notwithstanding its shortcomings. The Current Exposure Method relies on the Value-at-Risk methodology and its characteristics are discussed in this note. We will particularly investigate exposures to SAFCOM, the South African clearing house and point to a mathematical discrepancy on how netting is effected through the Basel accord.

  6. Progress in Geo-Electrical Methods for Hydrogeological Mapping?

    DEFF Research Database (Denmark)

    Schrøder, Niels

    2014-01-01

    In most of the 20th century the geo-electrical methods were primarily used for groundwater exploration and the application of the methods were normally followed by a borehole, and a moment of truth. In this process the use of DC (direct current) soundings have been developed to a high grade...... of excellence. In the last 25 years the geo-electrical methods are more used in connection with groundwater protection and planning, and new methods, as transient electromagnetic (TEM) soundings, have been developed that provide more measurements per hour. In Denmark this change is very explicit, and a paper....... The test area was earlier mapped by DC-soundings, so it is possible to test the methods against each other. It is concluded that well performed DC-soundings with a Schlumberger configuration still provide the best base for hydrogeological mapping...

  7. Measuring electric conductivity in liquid metals by eddy current method

    International Nuclear Information System (INIS)

    Zhuravlev, S.P.; Ostrovskij, O.I.; Grigoryan, V.A.

    1982-01-01

    Technique permitting to apply the method of vertiginous currents for investigation of electric conductivity of metal melts in the high temperature range is presented. Interferences affecting accuracy of measurements are specified and ways of their removing are pointed out. Scheme of measuring and design of the facility are described. Results of measuring electric resistance of liquid Fe, Co, Ni obtained for the first time by this method are presented. The data obtained agree with the results of measurements conducted by the method of the rotating magnetic field. Difference in absolute values of electric resistance in parallel experiments for each metal does not exceed 4%

  8. Study of the transport phenomena in III-V materials by the Monte Carlo method: application to INAS

    International Nuclear Information System (INIS)

    Bouazza, B.; Amer, L.; Guen-Bouazza, A.; Sayeh, C.; Chabanne-Sari, N.E.; Gontrand, C.

    2004-01-01

    Full text.The microelectronic comprehension of the phenomena which describes the behavior of the carriers in semiconductor materials requires the knowledge of energy distribution function. This distribution function is obtained by the resolution of Boltzmann equation which is very hard to solve analytically. Other methods based on modeling are actually successfully used to solve this equation. This Monte Carlo method is among of the most methods used for studying electronics components operations. It consists to follow the evolution of electron packets in real space, where each electron subjected to the electric field present in material goes interact with the crystal lattice. It is therefore an iterative process made up from a whole coasting flights stopped by acoustics interactions, polar and non polar optics, piezoelectric, inter-valley, impurity, ionization and surface. By applying this method to the III-V material: InAs. We can describe the behavior of the carriers from dynamic and energetic point of view (variation speed according to the field). The simulation is applied, taking into account variation of the carriers according to time in the non stationary mode, and the effect of temperature, and measurements doping. Results obtained are shown to be comparable to those of the theory

  9. Implementation of Electricity Business Competition Framework with Economic Dispatch Direct Method

    Directory of Open Access Journals (Sweden)

    Yusra Sabri

    2012-12-01

    Full Text Available Technically, electricity business under competition structure is more complex than that of vertically integrated one. The main prolems here are how to create an applicable competition framework and to solve electric calculations very quickly to obtain an optimal energi pricing, cost of losses, congestion and transportation costs by less than 15 minutes. This paper proposes a competition framework with the electric calculations, where a bilateral contract has been accommodated. Optimal energy price in the paper is calculated based on direct method of economic dispatch to obtain the result very quickly. The proposed method has been simulated to a 4-bus system. The simulation results show that the method works well and complies with the expectation. Therefore, electric power business under competition structure can be well realized by the proposed method.

  10. System and method for charging a plug-in electric vehicle

    Science.gov (United States)

    Bassham, Marjorie A.; Spigno, Jr., Ciro A.; Muller, Brett T.; Newhouse, Vernon L.

    2017-05-02

    A charging system and method that may be used to automatically apply customized charging settings to a plug-in electric vehicle, where application of the settings is based on the vehicle's location. According to an exemplary embodiment, a user may establish and save a separate charging profile with certain customized charging settings for each geographic location where they plan to charge their plug-in electric vehicle. Whenever the plug-in electric vehicle enters a new geographic area, the charging method may automatically apply the charging profile that corresponds to that area. Thus, the user does not have to manually change or manipulate the charging settings every time they charge the plug-in electric vehicle in a new location.

  11. Methods and apparatus of analyzing electrical power grid data

    Science.gov (United States)

    Hafen, Ryan P.; Critchlow, Terence J.; Gibson, Tara D.

    2017-09-05

    Apparatus and methods of processing large-scale data regarding an electrical power grid are described. According to one aspect, a method of processing large-scale data regarding an electrical power grid includes accessing a large-scale data set comprising information regarding an electrical power grid; processing data of the large-scale data set to identify a filter which is configured to remove erroneous data from the large-scale data set; using the filter, removing erroneous data from the large-scale data set; and after the removing, processing data of the large-scale data set to identify an event detector which is configured to identify events of interest in the large-scale data set.

  12. Systems and methods for producing electrical discharges in compositions

    KAUST Repository

    Cha, Min Suk

    2015-09-03

    Systems and methods configured to produce electrical discharges in compositions, such as those, for example, configured to produce electrical discharges in compositions that comprise mixtures of materials, such as a mixture of a material having a high dielectric constant and a material having a low dielectric constant (e.g., a composition of a liquid having a high dielectric constant and a liquid having a low dielectric constant, a composition of a solid having a high dielectric constant and a liquid having a low dielectric constant, and similar compositions), and further systems and methods configured to produce materials, such as through material modification and/or material synthesis, in part, resulting from producing electrical discharges in compositions.

  13. Practical Methods in Li-ion Batteries

    DEFF Research Database (Denmark)

    Barreras, Jorge Varela

    This thesis presents, as a collection of papers, practical methods in Li-ion batteries for simplified modeling (Manuscript I and II), battery electric vehicle design (III), battery management system testing (IV and V) and balancing system control (VI and VII). • Manuscript I tackles methodologies...... to parameterize battery models based solely on manufacturer’s datasheets • Manuscript II presents a parameterization method for battery models based on the notion of direct current resistance • Manuscript III proposes a battery electric vehicle design that combines fixed and swappable packs • Manuscript IV...... develops a battery system model for battery management system testing on a hardware-in-the-loop simulator • Manuscript V extends the previous work, introducing theoretical principles and presenting a practical method to develop ad hoc software and strategies for testing • Manuscript VI presents...

  14. New Method for Solving Inductive Electric Fields in the Ionosphere

    Science.gov (United States)

    Vanhamäki, H.

    2005-12-01

    We present a new method for calculating inductive electric fields in the ionosphere. It is well established that on large scales the ionospheric electric field is a potential field. This is understandable, since the temporal variations of large scale current systems are generally quite slow, in the timescales of several minutes, so inductive effects should be small. However, studies of Alfven wave reflection have indicated that in some situations inductive phenomena could well play a significant role in the reflection process, and thus modify the nature of ionosphere-magnetosphere coupling. The input to our calculation method are the time series of the potential part of the ionospheric electric field together with the Hall and Pedersen conductances. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called Cartesian Elementary Current Systems (CECS). This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfven wave reflection from uniformly conducting ionosphere.

  15. Interferometric methods for mapping static electric and magnetic fields

    DEFF Research Database (Denmark)

    Pozzi, Giulio; Beleggia, Marco; Kasama, Takeshi

    2014-01-01

    The mapping of static electric and magnetic fields using electron probes with a resolution and sensitivity that are sufficient to reveal nanoscale features in materials requires the use of phase-sensitive methods such as the shadow technique, coherent Foucault imaging and the Transport of Intensi......) the model-independent determination of the locations and magnitudes of field sources (electric charges and magnetic dipoles) directly from electron holographic data.......The mapping of static electric and magnetic fields using electron probes with a resolution and sensitivity that are sufficient to reveal nanoscale features in materials requires the use of phase-sensitive methods such as the shadow technique, coherent Foucault imaging and the Transport of Intensity...... on theoretical models that form the basis of the quantitative interpretation of electron holographic data. We review the application of electron holography to a variety of samples (including electric fields associated with p–n junctions in semiconductors, quantized magnetic flux in superconductors...

  16. III-V/Si wafer bonding using transparent, conductive oxide interlayers

    Energy Technology Data Exchange (ETDEWEB)

    Tamboli, Adele C., E-mail: Adele.Tamboli@nrel.gov; Hest, Maikel F. A. M. van; Steiner, Myles A.; Essig, Stephanie; Norman, Andrew G.; Bosco, Nick; Stradins, Paul [National Center for Photovoltaics, National Renewable Energy Laboratory, 15013 Denver West Pkwy, Golden, Colorado 80401 (United States); Perl, Emmett E. [Department of Electrical and Computer Engineering, University of California, Santa Barbara, California 93106-9560 (United States)

    2015-06-29

    We present a method for low temperature plasma-activated direct wafer bonding of III-V materials to Si using a transparent, conductive indium zinc oxide interlayer. The transparent, conductive oxide (TCO) layer provides excellent optical transmission as well as electrical conduction, suggesting suitability for Si/III-V hybrid devices including Si-based tandem solar cells. For bonding temperatures ranging from 100 °C to 350 °C, Ohmic behavior is observed in the sample stacks, with specific contact resistivity below 1 Ω cm{sup 2} for samples bonded at 200 °C. Optical absorption measurements show minimal parasitic light absorption, which is limited by the III-V interlayers necessary for Ohmic contact formation to TCOs. These results are promising for Ga{sub 0.5}In{sub 0.5}P/Si tandem solar cells operating at 1 sun or low concentration conditions.

  17. Electric Field Quantitative Measurement System and Method

    Science.gov (United States)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  18. Method of imaging the electrical conductivity distribution of a subsurface

    Science.gov (United States)

    Johnson, Timothy C.

    2017-09-26

    A method of imaging electrical conductivity distribution of a subsurface containing metallic structures with known locations and dimensions is disclosed. Current is injected into the subsurface to measure electrical potentials using multiple sets of electrodes, thus generating electrical resistivity tomography measurements. A numeric code is applied to simulate the measured potentials in the presence of the metallic structures. An inversion code is applied that utilizes the electrical resistivity tomography measurements and the simulated measured potentials to image the subsurface electrical conductivity distribution and remove effects of the subsurface metallic structures with known locations and dimensions.

  19. ENPEP and the microcomputer version of WASP-III: Overview and recent experience

    International Nuclear Information System (INIS)

    Buehring, W.A.; Wolsko, T.D.

    1987-01-01

    Argonne National Laboratory (ANL) has developed a microcomputer-based energy planning package entitled ENergy and Power Evaluation Program (ENPEP). It consists of seven technical modules, four commercial software packages, and an executive system that conveniently integrates the many options associated with performing energy studies. The seven technical modules and their functions are as follows: MACRO allows the user to specify macroeconomic growth (global or sectoral) that will be the drivers of energy demand. DEMAND projects energy demand based upon the macroeconomic growth information supplied in MACRO. PLANTDATA provides a library of technical data on electric generating plants that is used by BALANCE and ELECTRIC. BALANCE computes marketplace energy supply/demand balances over the study period. LOAD computes detailed electric load forecast information for use in ELECTRIC. ELECTRIC, the microcomputer (PC) version of WASP-III, calculates a minimum cost electric supply system to meet electric demand and reliability goals. IMPACTS calculates environmental impacts and resource requirements associated with energy supply system options. ENPEP provides the potential for energy planners in developing countries to carry out important studies without access to inconvenient and/or expensive mainframe computers. The ELECTRIC module of ENPEP provides electric system planners the opportunity to use the WASP-III model for expansion planning of electrical generating systems. Extensive efforts have been made in converting WASP-III to the microcomputer to provide user-friendly data entry forms and options for operations. (author). 3 refs, 20 figs

  20. Wet method for measuring starch gelatinization temperature using electrical conductivity.

    Science.gov (United States)

    Morales-Sanchez, E; Figueroa, J D C; Gaytan-Martínez, M

    2009-09-01

    The objective of the present study was to develop a method for obtaining the gelatinization temperature of starches by using electrical conductivity. Native starches from corn, rice, potato, and wheat were prepared with different proportions of water and heated from room temperature to 90 degrees C, in a device especially designed for monitoring the electrical conductivity as a function of temperature. The results showed a linear trend of the electrical conductivity with the temperature until it reaches the onset gelatinization temperature. After that point, the electrical conductivity presented an increment or decrement depending on the water content in the sample and it was related to starch swelling and gelatinization phenomena. At the end gelatinization temperature, the conductivity becomes stable and linear, indicating that there are no more changes of phase. The starch gelatinization parameter, which was evaluated in the 4 types of starches using the electrical conductivity, was compared with those obtained by using differential scanning calorimeter (DSC). The onset temperature at which the electrical conductivity increased or decreased was found to be similar to that obtained by DSC. Also, the final temperature at which the electrical conductivity returned to linearity matched the end gelatinization temperature of the DSC. Further, a wet method for measuring the onset, peak, and end gelatinization temperatures as a function of temperature using the electrical conductivity curves is presented for a starch-water suspension.

  1. Ion Implantation in III-V Compound Semiconductors

    Science.gov (United States)

    1984-09-01

    340 keV H + -0 Ga P  O UES-723-292 !:• (H o>ray *P-K X - rayO Ga-K X -ray iii! RBS * ..I -iO.. 0 10I to1. 01 • .0 -. I0 1 LI =i, O I 0 01 0.J 10...Identity by blo ," pume) Ion Implantation, GaAs, Hall effect, electrical resistivity, Rutherford Backscattering (RBS), channeling, Proton induced x -ray...Mebility (jH) upon Aiinealing Temperature (TA) for 1 X 101 /cm• Dose Samples of GaAs:Mg with Three Different Capping Methods 33 p 14 Dependence of Surface

  2. Methods of formation of efficiency indexes of electric power sources integration in regional electric power systems

    International Nuclear Information System (INIS)

    Marder, L.I.; Myzin, A.I.

    1993-01-01

    A methodic approach to the grounding of the integration process efficiency within the Unified electric power system is given together with the selection of a rational areal structure and concentration of power-generating source capacities. Formation of an economic functional according to alternative scenavies including the cost components taking account of the regional interests is considered. A method for estimation and distribution of the effect from electric power production integration in the power systems under new economic conditions is proposed

  3. Mobility in n-doped wurtzite III-Nitrides

    Directory of Open Access Journals (Sweden)

    C.G. Rodrigues

    2003-01-01

    Full Text Available A study of the mobility of n-doped wurtzite III-Nitrides is reported. We have determined the nonequilibrium thermodynamic state of the III-Nitrides systems driven far away from equilibrium by a strong electric field in the steady state, which follows after a very fast transient. The dependence of the mobility (which depends on the nonequilibrium thermodynamic state of the sample on the electric field strength is derived, which decreases with the strength of electric field. We analyzed the contributions to the mobility arising out of the different channels of electron scattering, namely, the polar optic, deformation, piezoelectric, interactions with the phonons, and with impurities. The case of n-InN, n-GaN, and n-AlN have been analyzed: as expected the main contribution comes from the polar-optic interactions in these strongly polar semiconductors. The other interactions are in decreasing order, the deformation acoustic, the piezoelectric, and the one due to impurities.

  4. Application of Electre III and DEA methods in the BPR of a bank branch network

    Directory of Open Access Journals (Sweden)

    Damaskos Xenofon

    2005-01-01

    Full Text Available Operational research methodologies are a powerful tool assisting managers in their effort to critically review business data and decide on future business actions. This paper presents the application of Electre multi-criteria methodology and Data Envelopment Analysis, as a part of a small commercial bank's ongoing effort to reengineer its branch network. We focus on two particular problems: first, categorization of the branches so as to apply adequate equivalent organizational schemas and second the assessment of relative efficiency of human resources.

  5. Redox control of electric melters with complex feed compositions. Part I: analytical methods and models

    International Nuclear Information System (INIS)

    Bickford, D.F.; Diemer, R.B. Jr.

    1985-01-01

    The redox state of glass from electric melters with complex feed compositions is determined by balance between gases above the melt, and transition metals and organic compounds in the feed. Part I discusses experimental and computational methods of relating flowrates and other melter operating conditions to the redox state of glass, and composition of the melter offgas. Computerized thermodynamic computational methods are useful in predicting the sequence and products of redox reactions and in assessing individual process variations. Melter redox state can be predicted by combining monitoring of melter operating conditions, redox measurement of fused melter feed samples, and periodic redox measurement of product. Mossbauer spectroscopy, and other methods which measure Fe(II)/Fe(III) in glass, can be used to measure melter redox state. Part II develops preliminary operating limits for the vitrification of High-Level Radioactive Waste. Limits on reducing potential to preclude the accumulation of combustible gases, accumulation of sulfides and selenides, and degradation of melter components are the most critical. Problems associated with excessively oxidizing conditions, such as glass foaming and potential ruthenium volatility, are controlled when sufficient formic acid is added to adjust melter feed rheology

  6. Colorimetric method for enzymatic screening assay of ATP using Fe(III)-xylenol orange complex formation.

    Science.gov (United States)

    Ishida, Akihiko; Yamada, Yasuko; Kamidate, Tamio

    2008-11-01

    In hygiene management, recently there has been a significant need for screening methods for microbial contamination by visual observation or with commonly used colorimetric apparatus. The amount of adenosine triphosphate (ATP) can serve as the index of a microorganism. This paper describes the development of a colorimetric method for the assay of ATP, using enzymatic cycling and Fe(III)-xylenol orange (XO) complex formation. The color characteristics of the Fe(III)-XO complexes, which show a distinct color change from yellow to purple, assist the visual observation in screening work. In this method, a trace amount of ATP was converted to pyruvate, which was further amplified exponentially with coupled enzymatic reactions. Eventually, pyruvate was converted to the Fe(III)-XO complexes through pyruvate oxidase reaction and Fe(II) oxidation. As the assay result, yellow or purple color was observed: A yellow color indicates that the ATP concentration is lower than the criterion of the test, and a purple color indicates that the ATP concentration is higher than the criterion. The method was applied to the assay of ATP extracted from Escherichia coli cells added to cow milk.

  7. Sensitivity of radiation methods of diagnosis of electric potentials in dielectric materials

    International Nuclear Information System (INIS)

    Sapozhkov, Yu.I.; Smekalin, L.F.; Yagushkin, N.I.

    1985-01-01

    On the base of the albedo method the characteristics of radiation methods of diagnosis of electric potentials inside dielectrics, such as sensitivity and resolution are considered. Investigations are carried out for electron energies of tens keV. It is shown that with energy growth the sensitivity to electric field in the dielectrics volume drops. The target atomic number growth reduces the sensitivity approximately 1/lnz. The albedo method resolution in the investigated energy range is constant. The results obtained testify to the usability radiation methods of the diagnosis for control of electric fields of dielectric structural materials in the course of their operation

  8. Methods for Estimation of Market Power in Electric Power Industry

    Science.gov (United States)

    Turcik, M.; Oleinikova, I.; Junghans, G.; Kolcun, M.

    2012-01-01

    The article is related to a topical issue of the newly-arisen market power phenomenon in the electric power industry. The authors point out to the importance of effective instruments and methods for credible estimation of the market power on liberalized electricity market as well as the forms and consequences of market power abuse. The fundamental principles and methods of the market power estimation are given along with the most common relevant indicators. Furthermore, in the work a proposal for determination of the relevant market place taking into account the specific features of power system and a theoretical example of estimating the residual supply index (RSI) in the electricity market are given.

  9. Position-controlled epitaxial III-V nanowires on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Roest, Aarnoud L; Verheijen, Marcel A; Wunnicke, Olaf; Serafin, Stacey; Wondergem, Harry; Bakkers, Erik P A M [Philips Research Laboratories, Professor Holstlaan 4, 5656 AA Eindhoven (Netherlands); Kavli Institute of NanoScience, Delft University of Technology, PO Box 5046, 2600 GA Delft (Netherlands)

    2006-06-14

    We show the epitaxial integration of III-V semiconductor nanowires with silicon technology. The wires are grown by the VLS mechanism with laser ablation as well as metal-organic vapour phase epitaxy. The hetero-epitaxial growth of the III-V nanowires on silicon was confirmed with x-ray diffraction pole figures and cross-sectional transmission electron microscopy. We show preliminary results of two-terminal electrical measurements of III-V nanowires grown on silicon. E-beam lithography was used to predefine the position of the nanowires.

  10. Position-controlled epitaxial III-V nanowires on silicon

    International Nuclear Information System (INIS)

    Roest, Aarnoud L; Verheijen, Marcel A; Wunnicke, Olaf; Serafin, Stacey; Wondergem, Harry; Bakkers, Erik P A M

    2006-01-01

    We show the epitaxial integration of III-V semiconductor nanowires with silicon technology. The wires are grown by the VLS mechanism with laser ablation as well as metal-organic vapour phase epitaxy. The hetero-epitaxial growth of the III-V nanowires on silicon was confirmed with x-ray diffraction pole figures and cross-sectional transmission electron microscopy. We show preliminary results of two-terminal electrical measurements of III-V nanowires grown on silicon. E-beam lithography was used to predefine the position of the nanowires

  11. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  12. Scanning tunneling microscopy III theory of STM and related scanning probe methods

    CERN Document Server

    Güntherodt, Hans-Joachim

    1996-01-01

    Scanning Tunneling Microscopy III provides a unique introduction to the theoretical foundations of scanning tunneling microscopy and related scanning probe methods. The different theoretical concepts developed in the past are outlined, and the implications of the theoretical results for the interpretation of experimental data are discussed in detail. Therefore, this book serves as a most useful guide for experimentalists as well as for theoreticians working in the filed of local probe methods. In this second edition the text has been updated and new methods are discussed.

  13. Study of Decision Framework of Shopping Mall Photovoltaic Plan Selection Based on DEMATEL and ELECTRE III with Symmetry under Neutrosophic Set Environment

    Directory of Open Access Journals (Sweden)

    Jiangbo Feng

    2018-05-01

    Full Text Available Rooftop distributed photovoltaic projects have been quickly proposed in China because of policy promotion. Before, the rooftops of the shopping mall had not been occupied, and it was urged to have a decision-making framework to select suitable shopping mall photovoltaic plans. However, a traditional multi-criteria decision-making (MCDM method failed to solve this issue at the same time, due to the following three defects: the interactions problems between the criteria, the loss of evaluation information in the conversion process, and the compensation problems between diverse criteria. In this paper, an integrated MCDM framework was proposed to address these problems. First of all, the compositive evaluation index was constructed, and the application of decision-making trial and evaluation laboratory (DEMATEL method helped analyze the internal influence and connection behind each criterion. Then, the interval-valued neutrosophic set was utilized to express the imperfect knowledge of experts group and avoid the information loss. Next, an extended elimination et choice translation reality (ELECTRE III method was applied, and it succeed in avoiding the compensation problem and obtaining the scientific result. The integrated method used maintained symmetry in the solar photovoltaic (PV investment. Last but not least, a comparative analysis using Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS method and VIKOR method was carried out, and alternative plan X1 ranks first at the same. The outcome certified the correctness and rationality of the results obtained in this study.

  14. Measurement of absolute displacement-amplitude of ultrasonic wave using piezo-electric detection method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seong Hyun; Kim, Jong Beom; Jhang, Kyung Young [Hanyang University, Seoul (Korea, Republic of)

    2017-02-15

    A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

  15. Measurement of absolute displacement-amplitude of ultrasonic wave using piezo-electric detection method

    International Nuclear Information System (INIS)

    Park, Seong Hyun; Kim, Jong Beom; Jhang, Kyung Young

    2017-01-01

    A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process

  16. Stripping demolition of reinforced concrete by electric heating method

    International Nuclear Information System (INIS)

    Nakagawa, Wahei; Nishita, Kiwamu; Kasai, Yoshio

    1993-01-01

    The present paper describes the procedures and results of a series of experiments the authors conducted to verify the efficiency of the electric heating method, previously proposed for so-called stripping demolition by applying electric current through reinforcing bars. In this method, a low voltage high current is run from one end to the other of a reinforcing bar or bars existing in a concrete structure, inducing intense heat in the bar(s) which in its turn brings about cracks in the surrounding concrete mass, facilitating secondary demolition by hammer picks or other means. The experiments were performed on full-scale biological shield wall mock-ups of a BWR and a small reactor. The results of the experiments are summarized as follows. (1) When electric current is applied through reinforcing bars, the bond between concrete and bars is loosened, and cracks start from one bar and progress toward other bars. Under appropriate conditions, the cracks in concrete run from the contact surface at one bar all the way to its the contact surface on another bar. (2) Cracks appear and grow only between two electrodes between which current is applied, not extending out of the area thus defined. (3) The concrete in the region closer to a current-bearing bar is intensely heated, whereas the concrete far from the bars remains nearly unheated. (4) Concrete walls after electric heating of bars disintegrates, if demolished with hammers, with the covering concrete are removed from the remaining portion of the structure together with heated bars, in shapes of flakes. (5) The reinforced concrete collapses in massive pieces of concrete, without generating much dust as is the case with the demolition of a concrete structure not heated by electricity. Results of the experiments show that the electric heating method is worth applying also to the demolition of nuclear power plants where concrete in the radioactivated surface region of shield walls needs to be stripped off in flakes

  17. Bulk Electric Load Cost Calculation Methods: Iraqi Network Comparative Study

    Directory of Open Access Journals (Sweden)

    Qais M. Alias

    2016-09-01

    Full Text Available It is vital in any industry to regain the spent capitals plus running costs and a margin of profits for the industry to flourish. The electricity industry is an everyday life touching industry which follows the same finance-economic strategy. Cost allocation is a major issue in all sectors of the electric industry, viz, generation, transmission and distribution. Generation and distribution service costing’s well documented in the literature, while the transmission share is still of need for research. In this work, the cost of supplying a bulk electric load connected to the EHV system is calculated. A sample basic lump-average method is used to provide a rough costing guide. Also, two transmission pricing methods are employed, namely, the postage-stamp and the load-flow based MW-distance methods to calculate transmission share in the total cost of each individual bulk load. The three costing methods results are then analyzed and compared for the 400kV Iraqi power grid considered for a case study.

  18. Price forecasting of day-ahead electricity markets using a hybrid forecast method

    International Nuclear Information System (INIS)

    Shafie-khah, M.; Moghaddam, M. Parsa; Sheikh-El-Eslami, M.K.

    2011-01-01

    Research highlights: → A hybrid method is proposed to forecast the day-ahead prices in electricity market. → The method combines Wavelet-ARIMA and RBFN network models. → PSO method is applied to obtain optimum RBFN structure for avoiding over fitting. → One of the merits of the proposed method is lower need to the input data. → The proposed method has more accurate behavior in compare with previous methods. -- Abstract: Energy price forecasting in a competitive electricity market is crucial for the market participants in planning their operations and managing their risk, and it is also the key information in the economic optimization of the electric power industry. However, price series usually have a complex behavior due to their nonlinearity, nonstationarity, and time variancy. In this paper, a novel hybrid method to forecast day-ahead electricity price is proposed. This hybrid method is based on wavelet transform, Auto-Regressive Integrated Moving Average (ARIMA) models and Radial Basis Function Neural Networks (RBFN). The wavelet transform provides a set of better-behaved constitutive series than price series for prediction. ARIMA model is used to generate a linear forecast, and then RBFN is developed as a tool for nonlinear pattern recognition to correct the estimation error in wavelet-ARIMA forecast. Particle Swarm Optimization (PSO) is used to optimize the network structure which makes the RBFN be adapted to the specified training set, reducing computation complexity and avoiding overfitting. The proposed method is examined on the electricity market of mainland Spain and the results are compared with some of the most recent price forecast methods. The results show that the proposed hybrid method could provide a considerable improvement for the forecasting accuracy.

  19. Price forecasting of day-ahead electricity markets using a hybrid forecast method

    Energy Technology Data Exchange (ETDEWEB)

    Shafie-khah, M., E-mail: miadreza@gmail.co [Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Moghaddam, M. Parsa, E-mail: parsa@modares.ac.i [Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Sheikh-El-Eslami, M.K., E-mail: aleslam@modares.ac.i [Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2011-05-15

    Research highlights: {yields} A hybrid method is proposed to forecast the day-ahead prices in electricity market. {yields} The method combines Wavelet-ARIMA and RBFN network models. {yields} PSO method is applied to obtain optimum RBFN structure for avoiding over fitting. {yields} One of the merits of the proposed method is lower need to the input data. {yields} The proposed method has more accurate behavior in compare with previous methods. -- Abstract: Energy price forecasting in a competitive electricity market is crucial for the market participants in planning their operations and managing their risk, and it is also the key information in the economic optimization of the electric power industry. However, price series usually have a complex behavior due to their nonlinearity, nonstationarity, and time variancy. In this paper, a novel hybrid method to forecast day-ahead electricity price is proposed. This hybrid method is based on wavelet transform, Auto-Regressive Integrated Moving Average (ARIMA) models and Radial Basis Function Neural Networks (RBFN). The wavelet transform provides a set of better-behaved constitutive series than price series for prediction. ARIMA model is used to generate a linear forecast, and then RBFN is developed as a tool for nonlinear pattern recognition to correct the estimation error in wavelet-ARIMA forecast. Particle Swarm Optimization (PSO) is used to optimize the network structure which makes the RBFN be adapted to the specified training set, reducing computation complexity and avoiding overfitting. The proposed method is examined on the electricity market of mainland Spain and the results are compared with some of the most recent price forecast methods. The results show that the proposed hybrid method could provide a considerable improvement for the forecasting accuracy.

  20. Comparison of Standard and Fast Charging Methods for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Petr Chlebis

    2014-01-01

    Full Text Available This paper describes a comparison of standard and fast charging methods used in the field of electric vehicles and also comparison of their efficiency in terms of electrical energy consumption. The comparison was performed on three-phase buck converter, which was designed for EV’s fast charging station. The results were obtained by both mathematical and simulation methods. The laboratory model of entire physical application, which will be further used for simulation results verification, is being built in these days.

  1. Thermodecomposition of lanthanides (III) and ytrium (III) glucoheptonates

    International Nuclear Information System (INIS)

    Giolito, J.

    1987-01-01

    The lanthanides (III) and yttrium (III) glucoheptonates as well the D-glucoheptono 1-4 lactone were studied using common analytical methods, elemental microanalysis of carbon and hydrogen, thermogravimetry and differential scanning calorimetry. These compounds were prepared from the reaction between the lanthanides (III) and yttrium (III) hydroxides and glucoheptonic acid aqueous solution obtained by means of the delta lactone hydrolysis of this acid. After stoichiometric reaction the compounds were precipitated by the addition of absolute ethanol, washed with the same solvent and dried in desiccator. Thermogravimetric the (TG) curves of the lanthanides glucoheptonates of the ceric group present thermal profiles with enough differences permitting an easy caracterization of each compound and the yttrium (III) glucoheptonate TG curve showed a great similarity with the erbium (III) compound TG curve. The differential scanning calometry (DSC) curves showed endothermic and exothermic peaks by their shape, height and position (temperature) permit an easy and rapid identification of each compound specially if DSC and TG curves were examined simultaneously. (author) [pt

  2. 3D electric field calculation with surface charge method

    International Nuclear Information System (INIS)

    Yamada, S.

    1992-01-01

    This paper describes an outline and some examples of three dimensional electric field calculations with a computer code developed at NIRS. In the code, a surface charge method is adopted because of it's simplicity in the mesh establishing procedure. The charge density in a triangular mesh is assumed to distribute with a linear function of the position. The electric field distribution is calculated for a pair of drift tubes with the focusing fingers on the opposing surfaces. The field distribution in an acceleration gap is analyzed with a Fourier-Bessel series expansion method. The calculated results excellently reproduces the measured data with a magnetic model. (author)

  3. Exploitation study of the ore-body ''Tigre III''. Open-cut design and study of high-recovery underground mining method for the Tigre III ore-body

    International Nuclear Information System (INIS)

    Baluszka, J.C.

    1980-01-01

    The paper first carries out an analysis for the purpose of determining the limiting sterile/ore ratio for open-cut and underground mining in the specific filling case of Tigre III. In this connection it considers a high-recovery method of underground mining (involving the use of cemented hydropneumatic chambers), a general mine plan covering access, transport, ventilation and removal of ore as well as auxiliary services relating to the Tigre III ore body as a whole. The costs of this method of mining are determined for purposes of comparison with the open-cut method. Similarly, the limiting sterile/ore ratio is taken as the basis for an analysis of different types of pit and a design suited to the limiting ratio is adopted. As a final solution the paper favours a method which combines open-cut and underground mining. It proposes the use of the open-cut method up to the limiting ratio (in accordance with the pit design chosen) and of underground method (by the filling chamber method) for the rest of the area. (author)

  4. Electrical field of electrical appliances versus distance: A preliminary analysis

    International Nuclear Information System (INIS)

    Mustafa, Nur Badariah Ahmad; Nordin, Farah Hani; Ismail, Fakaruddin Ali Ahmad; Alkahtani, Ammar Ahmed; Balasubramaniam, Nagaletchumi; Hock, Goh Chin; Shariff, Z A M

    2013-01-01

    Every household electrical appliance that is plugged in emits electric field even if it is not operating. The source where the appliance is plugged into and the components of household electrical appliance contribute to electric field emission. The electric field may cause unknown disturbance to the environment or also affect the human health and the effect might depends on the strength of the electric field emitted by the appliance. This paper will investigate the strength of the electric field emitted by four different electrical appliances using spectrum analyser. The strength will be captured at three different distances; (i) 1m (ii) 2m and (iii) 3m and analysis of the strength of the electrical field is done based on the three different distances. The measurement results show that the strength of the electric field is strongest when it is captured at 1m and the weakest at 3m from the electrical appliance. The results proved that the farther an object is located from the electrical appliance; the less effect the magnetic field has.

  5. A privacy-preserving sharing method of electricity usage using self-organizing map

    Directory of Open Access Journals (Sweden)

    Yuichi Nakamura

    2018-03-01

    Full Text Available Smart meters for measuring electricity usage are expected in electricity usage management. Although the relevant power supplier stores the measured data, the data are worth sharing among power suppliers because the entire data of a city will be required to control the regional grid stability or demand–supply balance. Even though many techniques and methods of privacy-preserving data mining have been studied to share data while preserving data privacy, a study on sharing electricity usage data is still lacking. In this paper, we propose a sharing method of electricity usage while preserving data privacy using a self-organizing map. Keywords: Privacy preserving, Data sharing, Self-Organizing map

  6. A method for short term electricity spot price forecasting

    International Nuclear Information System (INIS)

    Koreneff, G.; Seppaelae, A.; Lehtonen, M.; Kekkonen, V.; Laitinen, E.; Haekli, J.; Antila, E.

    1998-01-01

    In Finland, the electricity market was de-regulated in November 1995. For the electricity purchase of power companies this has caused big changes, since the old tariff based contracts of bulk power supply have been replaced by negotiated bilateral short term contracts and by power purchase from the spot market. In the spot market, in turn, there are at the present two strong actors: The electricity exchange of Finland and the Nordic power pool which is run by the Swedish and Norwegian companies. Today, the power companies in Finland have short term trade with both of the electricity exchanges. The aim of this chapter is to present methods for spot price forecasting in the electricity exchange. The main focus is given to the Finnish circumstances. In the beginning of the presentation, the practices of the electricity exchange of Finland are described, and a brief presentation is given on the different contracts, or electricity products, available in the spot market. For comparison, the practices of the Nordic electricity exchange are also outlined. A time series technique for spot price forecasting is presented. The structure of the model is presented, and its validity is tested using real case data obtained from the Finnish power market. The spot price forecasting model is a part of a computer system for distribution energy management (DEM) in a de-regulated power market

  7. A method for short term electricity spot price forecasting

    Energy Technology Data Exchange (ETDEWEB)

    Koreneff, G; Seppaelae, A; Lehtonen, M; Kekkonen, V [VTT Energy, Espoo (Finland); Laitinen, E; Haekli, J [Vaasa Univ. (Finland); Antila, E [ABB Transmit Oy (Finland)

    1998-08-01

    In Finland, the electricity market was de-regulated in November 1995. For the electricity purchase of power companies this has caused big changes, since the old tariff based contracts of bulk power supply have been replaced by negotiated bilateral short term contracts and by power purchase from the spot market. In the spot market, in turn, there are at the present two strong actors: The electricity exchange of Finland and the Nordic power pool which is run by the Swedish and Norwegian companies. Today, the power companies in Finland have short term trade with both of the electricity exchanges. The aim of this chapter is to present methods for spot price forecasting in the electricity exchange. The main focus is given to the Finnish circumstances. In the beginning of the presentation, the practices of the electricity exchange of Finland are described, and a brief presentation is given on the different contracts, or electricity products, available in the spot market. For comparison, the practices of the Nordic electricity exchange are also outlined. A time series technique for spot price forecasting is presented. The structure of the model is presented, and its validity is tested using real case data obtained from the Finnish power market. The spot price forecasting model is a part of a computer system for distribution energy management (DEM) in a de-regulated power market

  8. Preliminary Groundwater Assessment using Electrical Method at Quaternary Deposits Area

    Science.gov (United States)

    Hazreek, Z. A. M.; Raqib, A. G. A.; Aziman, M.; Azhar, A. T. S.; Khaidir, A. T. M.; Fairus, Y. M.; Rosli, S.; Fakhrurrazi, I. M.; Izzaty, R. A.

    2017-08-01

    Alternative water sources using groundwater has increasingly demand in recent years. In the past, proper and systematic study of groundwater potential was varies due to several constraints. Conventionally, tube well point was drilled based on subjective judgment of several parties which may lead to the uncertainties of the project success. Hence, this study performed an electrical method to investigate the groundwater potential at quaternary deposits area particularly using resistivity and induced polarization technique. Electrical method was performed using ABEM SAS4000 equipment based on pole dipole array and 2.5 m electrode spacing. Resistivity raw data was analyzed using RES2DINV software. It was found that groundwater was able to be detected based on resistivity and chargeability values which varied at 10 - 100 Ωm and 0 - 1 ms respectively. Moreover, suitable location of tube well was able to be proposed which located at 80 m from the first survey electrode in west direction. Verification of both electrical results with established references has shown some good agreement thus able to convince the result reliability. Hence, the establishment of electrical method in preliminary groundwater assessment was able to assist several parties in term groundwater prospective at study area which efficient in term of cost, time, data coverage and sustainability.

  9. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...

  10. Follow the money: A method for tracking electricity for environmental disclosure

    Energy Technology Data Exchange (ETDEWEB)

    Biewald, B.; White, D.; Woolf, T.

    1999-05-01

    In order to account for the sources and attributes of power sold at retail, it will be necessary to establish a system for tracking electricity from each generation source to each retail electricity seller through complex wholesale markets. In January 1998 the US Environmental Protection Agency (EPA) provided a grant to the New England Governor's Conference to investigate the development of an electricity tracking system for transactions in the New England Power Pool. The overall objective of the New England Tracking System (NETS) project was to develop a single, region-wide data collection and verification procedure to support compliance with, and enforcement of, environmental disclosure, RPS, GPS, green power standards, and other restructuring policies that might require accounting for the sources of electricity generation. The NETS method was designed to conform with the timing, contractual definitions, and rules and protocols that will be used by the New England Independent System Operator (ISO-NE) for financial settlement of the New England energy market. However, this method can be applied to other electricity control areas and power pools. In fact, establishing consistent methods across neighboring regions will help improve the accounting for the attributes of power that is sold between different regions. While there are many details and definitions underlying the NETS approach, there are two main steps in tracking electricity attributes. First, all transactions between market participants must be tracked, such that all electricity sold at retail is associated with a mix of generators. Second, the attributes of those generators (fuel type, air emissions, etc.) must be applied to the resource mix of each supplier. The first step--tracking the electricity from each generating unit to each load-serving entity (LSE)--is the focus of this article.

  11. Comparison of electric field exposure measurement methods under power lines

    International Nuclear Information System (INIS)

    Korpinen, L.; Kuisti, H.; Tarao, H.; Paeaekkoenen, R.; Elovaara, J.

    2014-01-01

    The object of the study was to investigate extremely low frequency (ELF) electric field exposure measurement methods under power lines. The authors compared two different methods under power lines: in Method A, the sensor was placed on a tripod; and Method B required the measurer to hold the meter horizontally so that the distance from him/her was at least 1.5 m. The study includes 20 measurements in three places under 400 kV power lines. The authors used two commercial three-axis meters, EFA-3 and EFA-300. In statistical analyses, they did not find significant differences between Methods A and B. However, in the future, it is important to take into account that measurement methods can, in some cases, influence ELF electric field measurement results, and it is important to report the methods used so that it is possible to repeat the measurements. (authors)

  12. 29 CFR 1910.305 - Wiring methods, components, and equipment for general use.

    Science.gov (United States)

    2010-07-01

    ... temporary wiring installations. (i) Temporary electrical power and lighting installations of 600 volts... project or purpose for which the wiring was installed. (iii) Temporary electrical installations of more... 29 Labor 5 2010-07-01 2010-07-01 false Wiring methods, components, and equipment for general use...

  13. Method validation for determination of gadolinium (III) and diethyl tetraamine pentaacetic acid (DTPA) ligand amount determination in Gd-DTPA contrast agent

    International Nuclear Information System (INIS)

    Rien Ritawidya; Martalena Ramli; Cecep Taufik Rustendi

    2014-01-01

    Gd-DTPA is one of the contrast agent which is important in Magnetic Resonance Imaging (MRI) application. The presence of free Gd (III) ion and free DTPA ligand is extremely toxic in human body. Therefore, it needs a method in order to determine free ion Gd (III) and free DTPA ligand concentration which then MRI would be applicable for clinical purpose. The analytical method that selected for the research was complexometric titration. The research was carried out in order to make validation method of free ion Gd (III) and free DTPA ligand determination, then validation criteria such as % recovery, % coefisien of variance and linearity could be obtained. Some experiments that had been done on determination of free Gd (III) with DTPA resulted in % recovery between 30,33% - 183,59%, the precision from %CV between 2,34% - 35,25% and linearity showed with value of R = 0,9525. Meanwhile on determination of DTPA with Gd (III) resulted in % recovery between 105.15% - 139,12%, %CV between 6,78% - 10,96% and R = 0,9525. Validation result indicates that determination method can not be used as a method to determine free ion Gd(III) and free DTPA ligand in contrast agent. (author)

  14. Development and Implementation of Efficiency-Improving Analysis Methods for the SAGE III on ISS Thermal Model Originating

    Science.gov (United States)

    Liles, Kaitlin; Amundsen, Ruth; Davis, Warren; Scola, Salvatore; Tobin, Steven; McLeod, Shawn; Mannu, Sergio; Guglielmo, Corrado; Moeller, Timothy

    2013-01-01

    The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument is the fifth in a series of instruments developed for monitoring aerosols and gaseous constituents in the stratosphere and troposphere. SAGE III will be delivered to the International Space Station (ISS) via the SpaceX Dragon vehicle in 2015. A detailed thermal model of the SAGE III payload has been developed in Thermal Desktop (TD). Several novel methods have been implemented to facilitate efficient payload-level thermal analysis, including the use of a design of experiments (DOE) methodology to determine the worst-case orbits for SAGE III while on ISS, use of TD assemblies to move payloads from the Dragon trunk to the Enhanced Operational Transfer Platform (EOTP) to its final home on the Expedite the Processing of Experiments to Space Station (ExPRESS) Logistics Carrier (ELC)-4, incorporation of older models in varying unit sets, ability to change units easily (including hardcoded logic blocks), case-based logic to facilitate activating heaters and active elements for varying scenarios within a single model, incorporation of several coordinate frames to easily map to structural models with differing geometries and locations, and streamlined results processing using an Excel-based text file plotter developed in-house at LaRC. This document presents an overview of the SAGE III thermal model and describes the development and implementation of these efficiency-improving analysis methods.

  15. Fujian electric system analysis and nuclear power planning

    International Nuclear Information System (INIS)

    Lin Jianwen; Fu Qiang; Cheng Ping

    1994-11-01

    The objective of the study is to conduct a long term electric expansion planning and nuclear power planning for Fujian Province. The Wien Automatic System Planning Package (WASP-III) is used to optimize the electric system. Probabilistic Simulation is one of the most favorite techniques for middle and long term generation and production cost planning of electric power system. The load duration curve is obtained by recording the load data of a time interval into a monotone non-increasing sense. Polynomial function is used to describe the load duration curve (LDC), and this LDC is prepared for probabilistic simulation in WASP-III. WASP-III is a dynamic optimizing module in the area of supply modelling. It could find out the economically optimal expansion plan for a power generating system over a period of up to thirty years, with the constraints given by the planners. The optimum is evaluated in terms of minimum discounted total costs. Generating costs, amount of energy not served and reliability of the system are analyzed in the system expansion planning by using the probabilistic simulation method. The following conclusions can be drawn from this study. Hydro electricity is the cheapest one of all available technologies and resources. After the large hydro station is committed at the end of 1995, more base load power plants are needed in the system. Coal-fired power plants with capacity of 600 MWe will be the most competitive power plants in the future of the system. At the end of the studying period, about half of the stalled capacity will be composed of these power plants. Nuclear power plants with capacity of 600 MWe are suitable for the system after the base load increases to a certain level. Oil combustion units will decrease the costs of the system. (12 tabs., 6 figs.)

  16. The Research of Regression Method for Forecasting Monthly Electricity Sales Considering Coupled Multi-factor

    Science.gov (United States)

    Wang, Jiangbo; Liu, Junhui; Li, Tiantian; Yin, Shuo; He, Xinhui

    2018-01-01

    The monthly electricity sales forecasting is a basic work to ensure the safety of the power system. This paper presented a monthly electricity sales forecasting method which comprehensively considers the coupled multi-factors of temperature, economic growth, electric power replacement and business expansion. The mathematical model is constructed by using regression method. The simulation results show that the proposed method is accurate and effective.

  17. Greenhouse gas emission factors of purchased electricity from interconnected grids

    International Nuclear Information System (INIS)

    Ji, Ling; Liang, Sai; Qu, Shen; Zhang, Yanxia; Xu, Ming; Jia, Xiaoping; Jia, Yingtao; Niu, Dongxiao; Yuan, Jiahai; Hou, Yong; Wang, Haikun; Chiu, Anthony S.F.; Hu, Xiaojun

    2016-01-01

    Highlights: • A new accounting framework is proposed for GHG emission factors of power grids. • Three cases are used to demonstrate the proposed framework. • Comparisons with previous system boundaries approve the necessity. - Abstract: Electricity trade among power grids leads to difficulties in measuring greenhouse gas (GHG) emission factors of purchased electricity. Traditional methods assume either electricity purchased from a grid is entirely produced locally (Boundary I) or imported electricity is entirely produced by the exporting grid (Boundary II) (in fact a blend of electricity produced by many grids). Both methods ignore the fact that electricity can be indirectly traded between grids. Failing to capture such indirect electricity trade can underestimate or overestimate GHG emissions of purchased electricity in interconnected grid networks, potentially leading to incorrectly accounting for the effects of emission reduction policies involving purchased electricity. We propose a “Boundary III” framework to account for emissions both directly and indirectly caused by purchased electricity in interconnected gird networks. We use three case studies on a national grid network, an Eurasian Continent grid network, and North Europe grid network to demonstrate the proposed Boundary III emission factors. We found that the difference on GHG emissions of purchased electricity estimated using different emission factors can be considerably large. We suggest to standardize the choice of different emission factors based on how interconnected the local grid is with other grids.

  18. A new method for the extraction of Au(III) with ethyl thioacetoacetate into chloroform

    International Nuclear Information System (INIS)

    Khan, S.Z.; Turel, Z.R.

    1985-01-01

    A method was developed for rapid and selective extraction of Au(III) with ethyl thioacetoacetate (HETAcAc) into chloroform at pH 4. The effect of various parameters on the extraction coefficient values were studied. The substoichiometry of the extracted species of 1:3 was obtained by slope ratio and substoichiometric extraction method, respectively. (author)

  19. Review of Electrical and Gravity Methods of Near-Surface ...

    African Journals Online (AJOL)

    USER

    ABSTRACT: The theory and practice of electrical and gravity methods of geophysics for groundwater exploration was reviewed with illustrations and data examples. With the goal of reducing cases of borehole/water-well failure attributed to the lack of the knowledge of the methods of geophysics for groundwater exploration ...

  20. Development of Early Warning Methods for Electric Power Systems

    DEFF Research Database (Denmark)

    Jóhannsson, Hjörtur

    This thesis concerns the development of methods that can provide, in realtime, an early warning for an emerging blackout in electric power systems. The blackout in E-Denmark and S-Sweden on September 23, 2003 is the main motivation for the method development. The blackout was caused by occurrence...

  1. Probabilist methods applied to electric source problems in nuclear safety

    International Nuclear Information System (INIS)

    Carnino, A.; Llory, M.

    1979-01-01

    Nuclear Safety has frequently been asked to quantify safety margins and evaluate the hazard. In order to do so, the probabilist methods have proved to be the most promising. Without completely replacing determinist safety, they are now commonly used at the reliability or availability stages of systems as well as for determining the likely accidental sequences. In this paper an application linked to the problem of electric sources is described, whilst at the same time indicating the methods used. This is the calculation of the probable loss of all the electric sources of a pressurized water nuclear power station, the evaluation of the reliability of diesels by event trees of failures and the determination of accidental sequences which could be brought about by the 'total electric source loss' initiator and affect the installation or the environment [fr

  2. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Directory of Open Access Journals (Sweden)

    H. Vanhamäki

    2006-10-01

    Full Text Available We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS. This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  3. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Science.gov (United States)

    Vanhamäki, H.; Amm, O.; Viljanen, A.

    2006-10-01

    We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS). This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  4. Nanolithography based contacting method for electrical measurements on single template synthesized nanowires

    DEFF Research Database (Denmark)

    Fusil, S.; Piraux, L.; Mátéfi-Tempfli, Stefan

    2005-01-01

    A reliable method enabling electrical measurements on single nanowires prepared by electrodeposition in an alumina template is described. This technique is based on electrically controlled nanoindentation of a thin insulating resist deposited on the top face of the template filled by the nanowires....... We show that this method is very flexible, allowing us to electrically address single nanowires of controlled length down to 100 nm and of desired composition. Using this approach, current densities as large as 10 A cm were successfully injected through a point contact on a single magnetic...

  5. Application of column tests and electrical resistivity methods for leachate transport monitoring

    Directory of Open Access Journals (Sweden)

    Wychowaniak Dorota

    2015-09-01

    Full Text Available Development of the human civilization leads to the pollution of environment. One of the contamination which are a real threat to soil and groundwater are leachates from landfills. In this paper the solute transport through soil was considered. For this purpose, the laboratory column tests of chlorides tracer and leachates transport on two soil samples have been carried out. Furthermore, the electrical resistivity method was applied as auxiliary tool to follow the movements of solute through the soil column what allowed to compare between the results obtained with column test method and electrical resistivity measurements. Breakthrough curves obtained by conductivity and resistivity methods represents similar trends which leads to the conclusion about the suitability of electrical resistivity methods for contamination transport monitoring in soil-water systems.

  6. Analysis of novel silicon and III-V solar cells by simulation and experiment; Analyse neuartiger Silizium- und III-V-Solarzellen mittels Simulation und Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hermle, Martin

    2008-11-27

    This work presents various simulation studies of silicon and III-V solar cells. For standard silicon solar cells, one of the critical parameters to obtain good performance, is the rear side recombination velocity. The optical and electrical differences of the different cell structures were determined. The optical differences and the effective recombination velocity Sback of the different rear side structures for 1 Ohmcm material were extracted. Beside standard silicon solar cells, back junction silicon solar cells were investigated. Especially the influence of the front surface field and the electrical shading due to the rear side, was investigated. In the last two chapters, III-V solar cells were analysed. For the simulation of III-V multi-junction solar cells, the simulation of the tunneldiode is the basic prerequisite. In this work, the numerical calibration of an GaAs tunneldiode was achieved by using an non-local tunnel model. Using this model, it was possible to successfully simulate a III-V tandem solar cell. The last chapter deals with an optimization of the III-V 3-junction cell for space applications. Especially the influence of the GaAs middle cell was investigated. Due to structural changes, the end-of-life efficiency was drastically increased.

  7. Control and Optimization Methods for Electric Smart Grids

    CERN Document Server

    Ilić, Marija

    2012-01-01

    Control and Optimization Methods for Electric Smart Grids brings together leading experts in power, control and communication systems,and consolidates some of the most promising recent research in smart grid modeling,control and optimization in hopes of laying the foundation for future advances in this critical field of study. The contents comprise eighteen essays addressing wide varieties of control-theoretic problems for tomorrow’s power grid. Topics covered include: Control architectures for power system networks with large-scale penetration of renewable energy and plug-in vehicles Optimal demand response New modeling methods for electricity markets Control strategies for data centers Cyber-security Wide-area monitoring and control using synchronized phasor measurements. The authors present theoretical results supported by illustrative examples and practical case studies, making the material comprehensible to a wide audience. The results reflect the exponential transformation that today’s grid is going...

  8. Short-term electric load forecasting using computational intelligence methods

    OpenAIRE

    Jurado, Sergio; Peralta, J.; Nebot, Àngela; Mugica, Francisco; Cortez, Paulo

    2013-01-01

    Accurate time series forecasting is a key issue to support individual and organizational decision making. In this paper, we introduce several methods for short-term electric load forecasting. All the presented methods stem from computational intelligence techniques: Random Forest, Nonlinear Autoregressive Neural Networks, Evolutionary Support Vector Machines and Fuzzy Inductive Reasoning. The performance of the suggested methods is experimentally justified with several experiments carried out...

  9. Relativistic many-body calculation of energies, transition rates, lifetimes, and multipole polarizabilities in Cs-like La iii

    Science.gov (United States)

    Safronova, U. I.; Safronova, M. S.

    2014-05-01

    Excitation energies of the [Xe]nd (n =5-9), [Xe]ns (n =6-10), [Xe]np (n =6-9), [Xe]nf (n =4-8), and [Xe]ng (n =5-8) states in La iii, where [Xe] = 1s22s22p63s23p63d104s24p64d105s25p6, are evaluated. Electric dipole matrix elements for the allowed transitions between the low-lying [Xe]nd, [Xe]ns, [Xe]np, [Xe]nf, and [Xe]ng states in the La iii ion are calculated using the high-precision relativistic all-order method where all single, double, and partial triple excitations of the Dirac-Fock wave functions are included to all orders of perturbation theory. Recommended values are provided for a large number of electric dipole matrix elements, oscillator strengths, transition rates, and lifetimes. Scalar and tensor polarizabilities of the states listed above are evaluated. The uncertainties of the recommended values are estimated. Electric quadrupole and magnetic dipole matrix elements are calculated to determine lifetimes of the 5d5/2 and 6s metastable levels. The ground-state E1, E2, and E3 static polarizabilities are calculated. This work provides recommended values critically evaluated for their accuracy for a number of La iii atomic properties for use in planning and analysis of various experiments as well as theoretical modeling.

  10. Study of decision framework of offshore wind power station site selection based on ELECTRE-III under intuitionistic fuzzy environment: A case of China

    International Nuclear Information System (INIS)

    Wu, Yunna; Zhang, Jinying; Yuan, Jianping; Geng, Shuai; Zhang, Haobo

    2016-01-01

    Highlights: • A novel MCDM framework is applied to assist group decision in OWPS site selection. • The index system consisting of veto and evaluation criteria is constructed. • A case study is carried five sites in coastal areas of Shandong in East China. - Abstract: Offshore wind power projects have been rapidly proposed in China due to policy promotion. Site selection immensely decides the success of any offshore wind power development and is a complex multi-criteria decision making (MCDM) problem. However, canonical MCDM methods tend to fail the site selection process due to the following three problems. Firstly, the compensation problem exists in information processing. Secondly, there exists the problem of incomplete utilization of decision information and information loss in the decision process. Thirdly, the interaction problem in the fuzzy environment is easy to be ignored. To deal with the above problems, this study builds a framework for offshore wind farm site selection decision utilizing Elimination et Choix Traduisant la Realité-III (ELECTRE-III) in the intuitionistic fuzzy environment. First of all, the comprehensive index system of OWPS site selection consisting of veto criteria and evaluation criteria is constructed. Then, the intuitionistic fuzzy set is used in the group decision for the decision makers to express the imperfect knowledge. Moreover, the generalized intuitionistic fuzzy ordered weighted geometric interaction averaging (GIFWGIA) operator is applied to deal with the interaction problem. Together with the likelihood-based valued comparisons, imprecise decision information is reasonably used and information loss problem is rationally avoided. Then a case of China is studied based on the proposed framework, demonstrating the site selection methodology valid and practical. This study implements evaluation method for offshore wind power site selection and also provides a theoretical basis for the development of offshore wind power

  11. Mid-Term Electricity Market Clearing Price Forecasting with Sparse Data: A Case in Newly-Reformed Yunnan Electricity Market

    Directory of Open Access Journals (Sweden)

    Chuntian Cheng

    2016-10-01

    Full Text Available For the power systems, for which few data are available for mid-term electricity market clearing price (MCP forecasting at the early stage of market reform, a novel grey prediction model (defined as interval GM(0, N model is proposed in this paper. Over the traditional GM(0, N model, three major improvements of the proposed model are: (i the lower and upper bounds are firstly identified to give an interval estimation of the forecasting value; (ii a novel whitenization method is then established to determine the definite forecasting value from the forecasting interval; and (iii the model parameters are identified by an improved particle swarm optimization (PSO instead of the least square method (LSM for the limitation of LSM. Finally, a newly-reformed electricity market in Yunnan province of China is studied, and input variables are contrapuntally selected. The accuracy of the proposed model is validated by observed data. Compared with the multiple linear regression (MLR model, the traditional GM(0, N model and the artificial neural network (ANN model, the proposed model gives a better performance and its superiority is further ensured by the use of the modified Diebold–Mariano (MDM test, suggesting that it is suitable for mid-term electricity MCP forecasting in a data-sparse electricity market.

  12. Extraction and separation studies of Ga(III, In(III and Tl(III using the neutral organophosphorous extractant, Cyanex-923

    Directory of Open Access Journals (Sweden)

    P. M. DHADKE

    2003-07-01

    Full Text Available The neutral extractant, Cyanes-923 has been used for the extraction and separation of gallium(III, indium(III and thallium(III from acidic solution. These metal ions were found to be quantitatively extracted with Cyanex-923 in toluene in the pH range 4.5–5.5, 5.0–6.5 and 1.5–3.0, respectively, and from the organic phase they can be stripped with 2.0 mol dm-3 HNO3, 3.0 mol dm-3 HNO3 and 3.0 mol dm-3 HCl, respectively. The effect of pH equilibration period, diluents, diverse ions and stripping agents on the extraction of Ga(III, In(III and Tl(III has been studied. The stroichiometry of the extracted species of these metal ions was determined on the basis of the slope analysis method. The reaction proceed by solvation and the probable extracted species found were [MCl3. 3Cyanex-923] [where M = Ga(III or In(III ] and [HTlCl4. 3Cyanex-923]. Based on these results a sequential procedure for the separation of Ga(III, In(III and Tl(III from each other was developed.

  13. System and method to determine electric motor efficiency using an equivalent circuit

    Science.gov (United States)

    Lu, Bin [Kenosha, WI; Habetler, Thomas G [Snellville, GA

    2011-06-07

    A system and method for determining electric motor efficiency includes a monitoring system having a processor programmed to determine efficiency of an electric motor under load while the electric motor is online. The determination of motor efficiency is independent of a rotor speed measurement. Further, the efficiency is based on a determination of stator winding resistance, an input voltage, and an input current. The determination of the stator winding resistance occurs while the electric motor under load is online.

  14. Effects of Synthesis Method on Electrical Properties of Graphene

    Science.gov (United States)

    Fuad, M. F. I. Ahmad; Jarni, H. H.; Shariffudin, W. N.; Othman, N. H.; Rahim, A. N. Che Abdul

    2018-05-01

    The aim of this study is to achieve the highest reduction capability and complete reductions of oxygen from graphene oxide (GO) by using different type of chemical methods. The modification of Hummer’s method has been proposed to produce GO, and hydrazine hydrate has been utilized in the GO’s reduction process into graphene. There are two types of chemical method are used to synthesize graphene; 1) Sina’s method and 2) Sasha’s method. Both GO and graphene were then characterized using X-Ray Powder Diffraction (XRD) and Fourier Transform Infrared Spectrometry (FT-IR). The graph patterns obtained from XRD showed that the values of graphene and GO are within their reliable ranges, FT-IR identified the comparison functional group between GO and graphene. Graphene was verified to experience the reduction process due to absent of functional group consist of oxygen has detected. Electrochemical impedance spectrometry (EIS) was then conducted to test the ability of conducting electricity of two batches (each weighted 1.6g) of graphene synthesized using different methods (Sina’s method and Sasha’s method). Sasha’s method was proven to have lower conductivity value compare to Sina’s method, with value of 6.2E+02 S/m and 8.1E+02 S/m respectively. These values show that both methods produced good graphene; however, by using Sina’s method, the graphene produced has better electrical properties.

  15. Electricity price forecast using Combinatorial Neural Network trained by a new stochastic search method

    International Nuclear Information System (INIS)

    Abedinia, O.; Amjady, N.; Shafie-khah, M.; Catalão, J.P.S.

    2015-01-01

    Highlights: • Presenting a Combinatorial Neural Network. • Suggesting a new stochastic search method. • Adapting the suggested method as a training mechanism. • Proposing a new forecast strategy. • Testing the proposed strategy on real-world electricity markets. - Abstract: Electricity price forecast is key information for successful operation of electricity market participants. However, the time series of electricity price has nonlinear, non-stationary and volatile behaviour and so its forecast method should have high learning capability to extract the complex input/output mapping function of electricity price. In this paper, a Combinatorial Neural Network (CNN) based forecasting engine is proposed to predict the future values of price data. The CNN-based forecasting engine is equipped with a new training mechanism for optimizing the weights of the CNN. This training mechanism is based on an efficient stochastic search method, which is a modified version of chemical reaction optimization algorithm, giving high learning ability to the CNN. The proposed price forecast strategy is tested on the real-world electricity markets of Pennsylvania–New Jersey–Maryland (PJM) and mainland Spain and its obtained results are extensively compared with the results obtained from several other forecast methods. These comparisons illustrate effectiveness of the proposed strategy.

  16. A robust flexible-probabilistic programming method for planning municipal energy system with considering peak-electricity price and electric vehicle

    International Nuclear Information System (INIS)

    Yu, L.; Li, Y.P.; Huang, G.H.; An, C.J.

    2017-01-01

    Highlights: • A robust flexible probabilistic programming method is developed for planning MES. • Multiple uncertainties with various violations and satisfaction levels are examined. • Solutions of considering peak electricity prices and electric vehicles are analyzed. • RFPP-MES can better improve energy system reliability and abate pollutant emission. - Abstract: Effective electric power systems (EPS) planning with considering electricity price of 24-h time is indispensable in terms of load shifting, pollutant mitigation and energy demand-supply reliability as well as reducing electricity expense of end-users. In this study, a robust flexible probabilistic programming (RFPP) method is developed for planning municipal energy system (MES) with considering peak electricity prices (PEPs) and electric vehicles (EVs), where multiple uncertainties regarded as intervals, probability distributions and flexibilities as well as their combinations can be effectively reflected. The RFPP-MES model is then applied to planning Qingdao’s MES, where electrical load of 24-h time is simulated based on Monte Carlo. Results reveal that: (a) different time intervals lead to changes of energy supply patterns, the energy supply patterns would tend to the transition from self-supporting dominated (i.e. in valley hours) to outsourcing-dominated (i.e. in peak hours); (b) 15.9% of total imported electricity expense would be reduced compared to that without considering PEPs; (c) with considering EVs, the CO_2 emissions of Qingdao’s transportation could be reduced directly and the reduction rate would be 2.5%. Results can help decision makers improve energy supply patterns, reduce energy system costs and abate pollutant emissions as well as adjust end-users’ consumptions.

  17. Method for analysing the adequacy of electric power systems with wind power plants and energy storages

    Directory of Open Access Journals (Sweden)

    Perzhabinsky Sergey

    2017-01-01

    Full Text Available Currently, renewable energy sources and energy storage devices are actively introduced into electric power systems. We developed method to analyze the adequacy of these electric power systems. The method takes into account the uncertainty of electricity generation by wind power plants and the processes of energy storage. The method is based on the Monte Carlo method and allowed to use of long-term meteorological data in open access. The performed experimental research of electrical power system is constructed on the basis of the real technical and meteorological data. The method allows to estimate of effectiveness of introducing generators based on renewable energy sources and energy storages in electric power systems.

  18. Research on the Value Evaluation of Used Pure Electric Car Based on the Replacement Cost Method

    Science.gov (United States)

    Tan, zhengping; Cai, yun; Wang, yidong; Mao, pan

    2018-03-01

    In this paper, the value evaluation of the used pure electric car is carried out by the replacement cost method, which fills the blank of the value evaluation of the electric vehicle. The basic principle of using the replacement cost method, combined with the actual cost of pure electric cars, puts forward the calculation method of second-hand electric car into a new rate based on the use of AHP method to construct the weight matrix comprehensive adjustment coefficient of related factors, the improved method of value evaluation system for second-hand car

  19. Electric power economy: comparative study of electric power consumption in many methods of outfloor control

    International Nuclear Information System (INIS)

    Kubota, Hideo; Tsitiya, Milton Tomoyuki

    1989-01-01

    This work presents a comparative study of the electric power consumption of a water elevatory station in order to verify which method is the most suitable in energy economy through the outflow variation in function of the demand

  20. Differential carrier lifetime and transport effects in electrically injected III-nitride light-emitting diodes

    Science.gov (United States)

    Rashidi, A.; Nami, M.; Monavarian, M.; Aragon, A.; DaVico, K.; Ayoub, F.; Mishkat-Ul-Masabih, S.; Rishinaramangalam, A.; Feezell, D.

    2017-07-01

    This work describes a small-signal microwave method for determining the differential carrier lifetime and transport effects in electrically injected InGaN/GaN light-emitting diodes (LEDs). By considering the carrier diffusion, capture, thermionic escape, and recombination, the rate equations are used to derive an equivalent small-signal electrical circuit for the LEDs, from which expressions for the input impedance and modulation response are obtained. The expressions are simultaneously fit to the experimental data for the input impedance and modulation response for nonpolar InGaN/GaN micro-LEDs on free-standing GaN substrates. The fittings are used to extract the transport related circuit parameters and differential carrier lifetimes. The dependence of the parameters on the device diameter and current density is reported. We also derive approximations for the modulation response under low and high injection levels and show that the transport of carriers affects the modulation response of the device, especially at low injection levels. The methods presented are relevant to the design of high-speed LEDs for visible-light communication.

  1. Prediction and optimization methods for electric vehicle charging schedules in the EDISON project

    DEFF Research Database (Denmark)

    Aabrandt, Andreas; Andersen, Peter Bach; Pedersen, Anders Bro

    2012-01-01

    project has been launched to investigate various areas relevant to electric vehicle integration. As part of EDISON an electric vehicle aggregator has been developed to demonstrate smart charging of electric vehicles. The emphasis of this paper is the mathematical methods on which the EDISON aggregator...

  2. Comparison of geochemical data obtained using four brine sampling methods at the SECARB Phase III Anthropogenic Test CO2 injection site, Citronelle Oil Field, Alabama

    Science.gov (United States)

    Conaway, Christopher; Thordsen, James J.; Manning, Michael A.; Cook, Paul J.; Trautz, Robert C.; Thomas, Burt; Kharaka, Yousif K.

    2016-01-01

    The chemical composition of formation water and associated gases from the lower Cretaceous Paluxy Formation was determined using four different sampling methods at a characterization well in the Citronelle Oil Field, Alabama, as part of the Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test, which is an integrated carbon capture and storage project. In this study, formation water and gas samples were obtained from well D-9-8 #2 at Citronelle using gas lift, electric submersible pump, U-tube, and a downhole vacuum sampler (VS) and subjected to both field and laboratory analyses. Field chemical analyses included electrical conductivity, dissolved sulfide concentration, alkalinity, and pH; laboratory analyses included major, minor and trace elements, dissolved carbon, volatile fatty acids, free and dissolved gas species. The formation water obtained from this well is a Na–Ca–Cl-type brine with a salinity of about 200,000 mg/L total dissolved solids. Differences were evident between sampling methodologies, particularly in pH, Fe and alkalinity. There was little gas in samples, and gas composition results were strongly influenced by sampling methods. The results of the comparison demonstrate the difficulty and importance of preserving volatile analytes in samples, with the VS and U-tube system performing most favorably in this aspect.

  3. TECHNICAL EVALUATION OF ELECTRICAL RESISTIVITY METHODS AT THE DEPARTMENT OF ENERGY HANFORD SITE

    International Nuclear Information System (INIS)

    PETERSEN SW

    2008-01-01

    There is a continuing need for cost-effective subsurface characterization within the vadose zone and groundwater at the U.S. Department of Energy (DOE) Hanford Site, Richland, Washington. With more than 1600 liquid and solid waste sites and 200 burial sites, contaminants have migrated to and through the vadose zone. In addition, future groundwater plumes may be generated from contaminants presently in the vadose zone. Relatively low-cost geophysical techniques can provide spatially extensive data that may provide information about the presence and extent of some contaminants. Recent electrical resistivity surveys at Hanford have provided encouraging results for mapping of some contaminants, such as nitrate, in the vadose zone. Because mobile radionuclides and trace elements may have been transported with nitrate through the vadose zone, the method may be used to map some mobile contaminants of concern, such as technetium-99 (99Tc). Validation of these recent electrical resistivity survey results remains to be completed. Electrical resistivity surveys have been conducted at various waste sites in the 200 Area of the Hanford Site: BC Cribs and Trenches (BCCT), T, S, U, C, B Tank Farms and the Purex Plant. Surveys have been completed using surface and well-to-well (WTW) array configurations. The goals of the surveys, as described by Fluor Hanford and CH2MHill Hanford staff, were to test the applicability of resistivity methods in identifying the presence of and mapping approximate extent of contaminant plumes within the vadose zone. The overall goal of the project was to evaluate the utility of electrical resistivity methods for characterizing contaminants of potential concern in the vadose zone in the 200 Area of the Hanford Site. The panel was asked to perform the following activities: (1) Evaluate recently completed and ongoing electrical resistivity projects at Hanford in terms of methodology used, results obtained, and lessons learned, with specific focus on (a

  4. New method for simultaneous determination of Fe(II) and Fe(III) in water using flow injection technique

    International Nuclear Information System (INIS)

    Kozak, J.; Gutowski, J.; Kozak, M.; Wieczorek, M.; Koscielniak, P.

    2010-01-01

    The method exploits the possibilities of flow injection gradient titration in a system of reversed flow with spectrophotometric detection. In the developed approach a small amount of titrant (EDTA) is injected into a stream of sample containing a mixture of indicators (sulfosalicylic acid and 1,10-phenanthroline). In acid environment sulfosalicylic acid forms a complex with Fe(III), whereas 1,10-phenanthroline forms a complex with Fe(II). Measurements are performed at wavelength λ = 530 nm when radiation is absorbed by both complexes. After injection EDTA replaces sulfosalicylic acid and forms with Fe(III) more stable colourless complex. As a result, a characteristic 'cut off' peak is registered with a width corresponding to the Fe(III) concentration and with a height corresponding to the Fe(II) concentration. Calibration was performed by titration of four two-component standard solutions of the Fe(II)/Fe(III) concentrations established in accordance with 2 2 factorial plan. The method was tested with the use of synthetic samples and then it was applied to the analysis of water samples taken from artesian wells. Under optimized experimental conditions Fe(II) and Fe(III) were determined with precision less than 0.8 and 2.5% (RSD) and accuracy less than 3.2 and 5.1% (relative error) within the concentration ranges of 0.1-3.0 and 0.9-3.5 mg L -1 of both analytes, respectively.

  5. The application of surface electrical and shallow geothermic methods in monitoring network design.

    Science.gov (United States)

    Gilkeson, R.H.; Cartwright, K.

    1983-01-01

    There are a variety of surface geophysical methods that are routinely used in geologic investigations. The three broad applications of these methods to evaluate the impact of waste disposal on shallow groundwater flow systems are: 1) evaluation of proposed waste disposal sites; 2) monitoring of site performance; and 3) investigation of contaminant migration at existing sites. Electrical and shallow geothermic are two surface geophysical methods that have application to waste disposal investigations. Of the electrical methods, electrical resistivity has the greatest application with a variety of techniques available. The distribution of temperature in shallow geologic materials (shallow geothermics) may define characteristics of shallow groundwater flow systems including zones of recharge and discharge and lithologic variation in the shallow geologic materials.-from Authors

  6. Electrospinning of Polyacrylonitrile Nanofibers and Simulation of Electric Field via Finite Element method

    Directory of Open Access Journals (Sweden)

    Hadi Samadian

    2017-04-01

    Full Text Available Objective(s: Since the electric field is the main driving force in electrospinning systems, the modeling and analysis of electric field distribution are critical to the nanofibers production. The aim of this study was modeling of the electric field and investigating the various parameters on polyacrylonitrile (PAN nanofibers morphology and diameter. Methods: The electric field profile at the nozzle and electrospinning zone was evaluated by Finite Element Method. The morphology and diameter of nanofibers were examined by Scanning electron microscopy (SEM. Results: The results of the electric field analysis indicated that the electric field was concentrated at the tip of the nozzle. Moreover, in the spinning direction, the electric field was concentrated at the surface of the spinneret and decayed rapidly toward the surface of the collector. Increasing polymer solution concentration from 7 to 11wt.% led to increasing nanofibers diameter form 77.76 ± 19.44 to 202.42 ± 36.85. Conclusions: Base on our results, it could be concluded that concentration of the electric field at the tip of the nozzle is high and initiates jet and nanofibers formation. PAN nanofibers can be transformed to carbon nanofibers which have various applications in biomedicine.

  7. A Design Method for Graded Insulation of Transformers by Transient Electric Field Intensity Analysis

    OpenAIRE

    Yamashita, Hideo; Cingoski, Vlatko; Namera, Akihiro; Nakamae, Eihachiro; Kitamura, Hideo

    2000-01-01

    In this paper, a calculation method for transient electric field distribution inside a transformer impressed with voltage is proposed: The concentrated electric network for the transformer is constructed by dividing transformer windings into several blocks, and the transient voltage and electric field intensity distributions inside the transformer are calculated by using the axisymmetrical finite element method. Moreover, an animated display of the distributions is realized: The visualization...

  8. Analytical method to evaluate fuel consumption of hybrid electric vehicles at balanced energy content of the electric storage devices

    Energy Technology Data Exchange (ETDEWEB)

    Katrasnik, Tomaz [University of Ljubljana, Faculty of Mechanical Engineering, Askerceva 6, 1000 Ljubljana (Slovenia)

    2010-11-15

    Innovative analytically based method to calculate corrected fuel consumption of parallel and series hybrid electric vehicles (HEVs) at balanced energy content of the electric storage devices is proposed and validated in the paper. The proposed analytical method is generally applicable and features highly accurate corrected fuel consumption results. It enables calculation of the corrected fuel consumption out of a single fuel consumption test run in a single analytic post-processing step. An additional fuel consumption test run might be needed to obtain highly accurate results if ratio of the energy content deviation of the electric storage devices to the energy used for vehicle propulsion over the test cycle is high. Proposed method enables consideration of non-linear energy flow changes and non-linear HEV component efficiency changes caused by the energy management strategy or by the component characteristics. The method therefore features highly accurate results out of the minimum number of fuel consumption test runs and thus optimizes workload for development or optimization of HEVs. The input data of the method are characteristic energy flows and efficiencies that are derived from the energy flows on selected energy paths of HEVs. (author)

  9. Electrical Resistivity Measurement of Petroleum Coke Powder by Means of Four-Probe Method

    Science.gov (United States)

    Rouget, G.; Majidi, B.; Picard, D.; Gauvin, G.; Ziegler, D.; Mashreghi, J.; Alamdari, H.

    2017-10-01

    Carbon anodes used in Hall-Héroult electrolysis cells are involved in both electrical and chemical processes of the cell. Electrical resistivity of anodes depends on electrical properties of its constituents, of which carbon coke aggregates are the most prevalent. Electrical resistivity of coke aggregates is usually characterized according to the ISO 10143 standardized test method, which consists of measuring the voltage drop in the bed of particles between two electrically conducing plungers through which the current is also applied. Estimation of the electrical resistivity of coke particles from the resistivity of particle bed is a challenging task and needs consideration of the contribution of the interparticle void fraction and the particle/particle contact resistances. In this work, the bed resistivity was normalized by subtracting the interparticle void fraction. Then, the contact size was obtained from discrete element method simulation and the contact resistance was calculated using Holm's theory. Finally, the resistivity of the coke particles was obtained from the bed resistivity.

  10. Monitoring methods of drift chamber characteristics. Application to SPES III detection

    International Nuclear Information System (INIS)

    Kerboul, C.

    1984-05-01

    For the SPES III spectrometer at the Laboratoire National Saturne, a large detection system has been developed which consists of three drift chambers for localization of the particle trajectories. Performances of these detectors for high spatial resolution depend greatly on different parameters such as anode current, gas mixture, drift velocity, efficiency, etc. The present work summarizes a set of methods necessary to the control of these parameters, for achieving the high resolution essentiel for the nuclear physic at intermediate energy [fr

  11. An Extensive Unified Thermo-Electric Module Characterization Method

    Science.gov (United States)

    Attivissimo, Filippo; Guarnieri Calò Carducci, Carlo; Lanzolla, Anna Maria Lucia; Spadavecchia, Maurizio

    2016-01-01

    Thermo-Electric Modules (TEMs) are being increasingly used in power generation as a valid alternative to batteries, providing autonomy to sensor nodes or entire Wireless Sensor Networks, especially for energy harvesting applications. Often, manufacturers provide some essential parameters under determined conditions, like for example, maximum temperature difference between the surfaces of the TEM or for maximum heat absorption, but in many cases, a TEM-based system is operated under the best conditions only for a fraction of the time, thus, when dynamic working conditions occur, the performance estimation of TEMs is crucial to determine their actual efficiency. The focus of this work is on using a novel procedure to estimate the parameters of both the electrical and thermal equivalent model and investigate their relationship with the operating temperature and the temperature gradient. The novelty of the method consists in the use of a simple test configuration to stimulate the modules and simultaneously acquire electrical and thermal data to obtain all parameters in a single test. Two different current profiles are proposed as possible stimuli, which use depends on the available test instrumentation, and relative performance are compared both quantitatively and qualitatively, in terms of standard deviation and estimation uncertainty. Obtained results, besides agreeing with both technical literature and a further estimation method based on module specifications, also provides the designer a detailed description of the module behavior, useful to simulate its performance in different scenarios. PMID:27983575

  12. Passivation of electrically active centers by Hydrogen and Lithium in Semiconductors

    CERN Multimedia

    2002-01-01

    The hyperfine technique of Perturbed Angular Correlation Spectroscopy (PAC) has proven to be excellently suited for the microscopic investigation of impurity complexes in semiconductors. But this method is seriously limited by the small number of chemically different isotopes which are suitable for PAC measurements and represent electrically active centers in semiconductors. This bottleneck can be widely overcome by the ISOLDE facility which provides a great variety of shortliving PAC isotopes. The probe atom $^{111m}$Cd, provided by ISOLDE opened the first successful access to PAC investigations of III-V compounds and enabled also the first PAC experiments on double acceptors in silicon and germamum. \\\\ \\\\ At the new ISOLDE facility our experiments were concentrated on the passivation of electrically active centres by hydrogen and lithium in Si, Ge and III-V compounds. Experiments on $^{111m}$Cd in Ge revealed the formation of two different acceptor hydrogen and two different acceptor lithium complexes respe...

  13. Nanocrystalline Axially Bridged Iron Phthalocyanine Polymeric Conductor: (μ-Thiocyanato(phthalocyaninatoiron(III

    Directory of Open Access Journals (Sweden)

    Eiza Shimizu

    2016-01-01

    Full Text Available Skewered Iron(III phthalocyanine conducting polymer can be constructed with the utilization of axial thiocyanato ligands ((μ-thiocyanato(phthalocyaninatoiron(III; (FeIII(Pc(SCNn thereby creating additional avenues for electron transport through a linear SCN bridge, apart from the intermolecular π-π orbital overlap between the Pc molecules. In this paper, we report on the conversion of bulk FeIII(Pc(SCNn polymeric organic conductor into crystalline nanostructures through horizontal vapor phase growth process. The needle-like nanostructures are deemed to provide more ordered and, thus, more π-π interactive interskewer FeIII(Pc(SCNn polymer orientation, resulting in a twofold increase of its electrical conductivity per materials density unit.

  14. Systems and methods for an integrated electrical sub-system powered by wind energy

    Science.gov (United States)

    Liu, Yan [Ballston Lake, NY; Garces, Luis Jose [Niskayuna, NY

    2008-06-24

    Various embodiments relate to systems and methods related to an integrated electrically-powered sub-system and wind power system including a wind power source, an electrically-powered sub-system coupled to and at least partially powered by the wind power source, the electrically-powered sub-system being coupled to the wind power source through power converters, and a supervisory controller coupled to the wind power source and the electrically-powered sub-system to monitor and manage the integrated electrically-powered sub-system and wind power system.

  15. Research and technology management in the electricity industry methods, tools and case studies

    CERN Document Server

    Daim, Tugrul; Kim, Jisun

    2013-01-01

    Technologies such as renewable energy alternatives including wind, solar and biomass, storage technologies and electric engines are creating a different landscape for the  electricity industry. Using sources and ideas from technologies such as renewable energy alternatives, Research and Technology Management in the Electricity Industry explores a different landscape for this industry and applies it to the electric industry supported by real industry cases. Divided into three sections, Research and Technology Management in the Electricity Industry introduces a range of  methods and tools includ

  16. Frequency domain methods applied to forecasting electricity markets

    International Nuclear Information System (INIS)

    Trapero, Juan R.; Pedregal, Diego J.

    2009-01-01

    The changes taking place in electricity markets during the last two decades have produced an increased interest in the problem of forecasting, either load demand or prices. Many forecasting methodologies are available in the literature nowadays with mixed conclusions about which method is most convenient. This paper focuses on the modeling of electricity market time series sampled hourly in order to produce short-term (1 to 24 h ahead) forecasts. The main features of the system are that (1) models are of an Unobserved Component class that allow for signal extraction of trend, diurnal, weekly and irregular components; (2) its application is automatic, in the sense that there is no need for human intervention via any sort of identification stage; (3) the models are estimated in the frequency domain; and (4) the robustness of the method makes possible its direct use on both load demand and price time series. The approach is thoroughly tested on the PJM interconnection market and the results improve on classical ARIMA models. (author)

  17. Risk Reduction Methods for Managing the Development of Regional Electric Power Industry

    Directory of Open Access Journals (Sweden)

    Mikhail Kozhevnikov

    2017-11-01

    Full Text Available The development of the regional electric power industry has come to the forefront due to the changing scale, quality, and configuration of electric power infrastructure, and the spread of distributed generation. This gives rise to more stringent requirements regarding the reliability, safety, and environmental impact of electric power supply. This article aims to justify a package of methods that make it possible to identify and minimize investment, production, financial, and environmental risks in order to ensure sustainable development of the regional electric power industry that performs anti-crisis functions, and of individual energy companies. The key method to be employed is integrated resource planning (IRP. As a part of the method, energy conservation, renewable energy sources, and combined heat and power production are considered as equally valid ways of meeting future demand. The authors have designed a methodology for taking into account uncertainty and risk when implementing IRP. The methodology includes analysis of scenarios and decision making processes by calculating past and projected values of profit indicators. When conducting the environmental and economic assessment of an investment project in the electric power industry, the authors suggest using an aggregate indicator of environmental and economic effectiveness that is calculated on the basis of a combination of locally significant positive and negative environmental and economic impacts of the project. The authors formulate conceptual provisions that serve as the foundation for a promising model of the regional electric power industry and which contain recommendations for managing the development of the industry while minimizing organizational, market, and technological risks.

  18. New method of measuring electric dipole moments in storage rings

    NARCIS (Netherlands)

    Farley, FJM; Jungmann, K; Miller, JP; Morse, WM; Orlov, YF; Roberts, BL; Semertzidis, YK; Silenko, A; Stephenson, EJ

    2004-01-01

    A new highly sensitive method of looking for electric dipole moments of charged particles in storage rings is described. The major systematic errors inherent in the method are addressed and ways to minimize them are suggested. It seems possible to measure the muon EDM to levels that test speculative

  19. Wet etch methods for InAs nanowire patterning and self-aligned electrical contacts

    Science.gov (United States)

    Fülöp, G.; d'Hollosy, S.; Hofstetter, L.; Baumgartner, A.; Nygård, J.; Schönenberger, C.; Csonka, S.

    2016-05-01

    Advanced synthesis of semiconductor nanowires (NWs) enables their application in diverse fields, notably in chemical and electrical sensing, photovoltaics, or quantum electronic devices. In particular, indium arsenide (InAs) NWs are an ideal platform for quantum devices, e.g. they may host topological Majorana states. While the synthesis has been continously perfected, only a few techniques have been developed to tailor individual NWs after growth. Here we present three wet chemical etch methods for the post-growth morphological engineering of InAs NWs on the sub-100 nm scale. The first two methods allow the formation of self-aligned electrical contacts to etched NWs, while the third method results in conical shaped NW profiles ideal for creating smooth electrical potential gradients and shallow barriers. Low temperature experiments show that NWs with etched segments have stable transport characteristics and can serve as building blocks of quantum electronic devices. As an example we report the formation of a single electrically stable quantum dot between two etched NW segments.

  20. Fluorimetric determination of samarium(III) and europium(III) in neodymium oxide by separation with a resin column

    Energy Technology Data Exchange (ETDEWEB)

    Shaorong Liu; Jian Meng (Beijing Research Institute of Chemical Engineering and Metallurgy (China)); Wenhua Liu (General Research Institute for Non-Ferrous Metals (China))

    1992-08-24

    When thenoyltrifluoroacetone-phenanthroline-Triton X-100 is used to determine samarium(III) and europium(III) fluorimetrically, only a limited amount of neodymium(III) can be tolerated. By using an on- line separation which can partially separate neodymium(III) from samarium(III), a practical and convenient method was developed to detect samarium(III) at concentrations >0.05% and europium(III) at concentrations >0.005% in neodymium oxide. (author). 7 refs.; 4 figs.; 3 tabs.

  1. Fluorimetric determination of samarium(III) and europium(III) in neodymium oxide by separation with a resin column

    International Nuclear Information System (INIS)

    Shaorong Liu; Jian Meng; Wenhua Liu

    1992-01-01

    When thenoyltrifluoroacetone-phenanthroline-Triton X-100 is used to determine samarium(III) and europium(III) fluorimetrically, only a limited amount of neodymium(III) can be tolerated. By using an on- line separation which can partially separate neodymium(III) from samarium(III), a practical and convenient method was developed to detect samarium(III) at concentrations >0.05% and europium(III) at concentrations >0.005% in neodymium oxide. (author). 7 refs.; 4 figs.; 3 tabs

  2. SEPARATION OF Fe (III, Cr(III, Cu(II, Ni(II, Co(II, AND Pb(II METAL IONS USING POLY(EUGENYL OXYACETIC ACID AS AN ION CARRIER BY A LIQUID MEMBRANE TRANSPORT METHOD

    Directory of Open Access Journals (Sweden)

    La Harimu

    2010-06-01

    Full Text Available Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II  metal ions had been separated using poly(eugenyl oxyacetic acid as an ion carrier by bulk liquid membrane transport method. The effect of pH, polyeugenyl oxyacetic acid ion carrier concentration, nitric acid concentration in the stripping solution, transport time, and metal concentration were optimized. The result showed that the optimum condition for transport of metal ions was at pH 4 for ion Fe(III and at pH 5 for Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions. The carrier volumes were optimum with concentration of 1 x 10-3 M at 7.5 mL for Cr(III, Cu (II,  Ni(II, Co(II ions and at 8.5 mL for Fe(III and Pb(II ions. The concentration of HNO3 in stripping phase was optimum at 2 M for Fe(III and Cu(II ions, 1 M for Cr(III, Ni(II and Co(II ions, and 0.5 M for Pb(II ion. The optimum transport times were 36 h for Fe(III and Co(II ions, and 48 h for Cr(III, Cu (II, Ni(II, and Pb(II ions. The concentration of metal ions accurately transported were 2.5 x 10-4 M for Fe(III and Cr(III ions, and 1 M for Cu (II, Ni(II, Co(II, and Pb(II ions. Compared to other metal ions the transport of Fe(III was the highest with selectivity order of Fe(III > Cr(III > Pb(II > Cu(II > Ni(II > Co(II. At optimum condition, Fe(III ion was transported through the membrane at 46.46%.   Keywords: poly(eugenyl oxyacetic acid, transport, liquid membrane, Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions

  3. Considerations Related to LTO for Gen II/III NPP

    International Nuclear Information System (INIS)

    Cojan, Mihail

    2012-01-01

    Today there are some 435 nuclear power reactors operating in 30 countries with a combined capacity of over 372 GWe. In 2011 these provided 2518 billion kWh, about 14% of the world's electricity [1]. The next evolutionary design of Generation III reactors to be deployed over many decades will represent a large part of the worldwide fleet throughout the 21st century. Generation III reactors are the future NPPs with improved safety and reliability, with passive safety systems and with a very low probability for core melt. The objective of this paper is to present the R and D activities that support LTO for Generation II / III Nuclear Reactors. (author)

  4. Restructuring the Electricity Industry

    DEFF Research Database (Denmark)

    Boom, Anette; Buehler, Stefan

    We study the role of vertical structure in determining generating capacities and retail prices in the electricity industry. Allowing for uncertain demand, we compare three market configurations: (i) integrated monopoly, (ii) integrated duopoly with wholesale trade, and (iii) separated duopoly wit...

  5. Smart electric vehicle (EV) charging and grid integration apparatus and methods

    Science.gov (United States)

    Gadh, Rajit; Mal, Siddhartha; Prabhu, Shivanand; Chu, Chi-Cheng; Sheikh, Omar; Chung, Ching-Yen; He, Lei; Xiao, Bingjun; Shi, Yiyu

    2015-05-05

    An expert system manages a power grid wherein charging stations are connected to the power grid, with electric vehicles connected to the charging stations, whereby the expert system selectively backfills power from connected electric vehicles to the power grid through a grid tie inverter (if present) within the charging stations. In more traditional usage, the expert system allows for electric vehicle charging, coupled with user preferences as to charge time, charge cost, and charging station capabilities, without exceeding the power grid capacity at any point. A robust yet accurate state of charge (SOC) calculation method is also presented, whereby initially an open circuit voltage (OCV) based on sampled battery voltages and currents is calculated, and then the SOC is obtained based on a mapping between a previously measured reference OCV (ROCV) and SOC. The OCV-SOC calculation method accommodates likely any battery type with any current profile.

  6. Fuel coolant interaction experiment by direct electrical heating method

    International Nuclear Information System (INIS)

    Takeda, Tsuneo; Hirano, Kenmei

    1979-01-01

    In the PCM (Power Cooling Mismatch) experiments, the FCI (Fuel Coolant Interaction) test is one of necessary tests in order to predict various phenomena that occur during PCM in the core. A direct electrical heating method is used for the FCI tests for fuel pellet temperature of over 1000 0 C. Therefore, preheating is required before initiating the direct electrical heating. The fuel pin used in the FCI tests is typical LWR fuel element, which is surrounded by coolant water. It is undersirable to heat up the coolant water during preheating of the fuel pin. Therefore, a zirconia (ZrO 2 ) pellet which is similar to a UO 2 pellet in physical and chemical properties is used. Electric property (electric conductivity) of ZrO 2 is particularly suitable for direct electrical heating as in the case of UO 2 . In this experiment, ZrO 2 pellet (melting point 2500 0 C) melting was achieved by use of both preheating and direct electrical heating. Temperature changes of coolant and fuel surface, as well as the pressure change of coolant water, were measured. The molten fuel interacted with the coolant and generated shock waves. A portion of this molten fuel fragmented into small particles during this interaction. The peak pressure of the observed shock wave was about 35 bars. The damaged fuel pin was photographed after disassembly. This report shows the measured coolant pressure changes and the coolant temperature changes, as well as photographs of damaged fuel pin and fuel fragments. (author)

  7. Benchmarking electrical methods for rapid estimation of root biomass.

    Science.gov (United States)

    Postic, François; Doussan, Claude

    2016-01-01

    To face climate change and subsequent rainfall instabilities, crop breeding strategies now include root traits phenotyping. Rapid estimation of root traits in controlled conditions can be achieved by using parallel electrical capacitance and its linear correlation with root dry mass. The aim of the present study was to improve robustness and efficiency of methods based on capacitance and other electrical variables, such as serial/parallel resistance, conductance, impedance or reactance. Using different electrode configurations and stem contact electrodes, we have measured the electrical impedance spectra of wheat plants grown in pots filled with three types of soil. For each configuration, parallel capacitance and other linearly independent electrical variables were computed and their quality as root dry mass estimator was evaluated by a 'sensitivity score' that we derived from Pearson's correlation coefficient r and linear regression parameters. The highest sensitivity score was obtained by parallel capacitance at an alternating current frequency of 116 Hz in three-terminal configuration. Using a clamp, instead of a needle, as a stem electrode did not significantly affect the capacitance measurements. Finally, in handheld LCR meter equivalent conditions, capacitance had the highest sensitivity score and determination coefficient (r (2) = 0.52) at 10 kHz frequency. Our benchmarking of linear correlations between different electrical variables and root dry mass enables to determine more coherent practices for ensuring a sensitive and robust root dry mass estimation, including in handheld LCR meter conditions. This would enhance the value of electrical capacitance as a tool for screening crops in relation with root systems in breeding programs.

  8. Review of Electrical and Gravity Methods of Near-Surface ...

    African Journals Online (AJOL)

    USER

    In every big city, dozen of new boreholes or hand-dug wells are .... This paper is a review of the electrical and gravity methods of ... audience/readership. II. ..... W. W. Northon and Company, New York. Butler ... McGraw Hill Books Co. New York ...

  9. Soluble dendrimers europium(III) β-diketonate complex for organic memory devices

    International Nuclear Information System (INIS)

    Wang Binbin; Fang Junfeng; Li Bin; You Han; Ma Dongge; Hong Ziruo; Li Wenlian; Su Zhongmin

    2008-01-01

    We report the synthesis of a soluble dendrimers europium(III) complex, tris(dibenzoylmethanato)(1,3,5-tris[2-(2'-pyridyl) benzimidazoly]methylbenzene)-europium(III), and its application in organic electrical bistable memory device. Excellent stability that ensured more than 10 6 write-read-erase-reread cycles has been performed in ambient conditions without current-induced degradation. High-density, low-cost memory, good film-firming property, fascinating thermal and morphological stability allow the application of the dendrimers europium(III) complex as an active medium in non-volatile memory devices

  10. METHODICS, SOFTWARE AND LABORATORY EQUIPMENT FOR AN INNOVATIVE ELECTRICAL ENGINEERING DISCIPLINE

    Directory of Open Access Journals (Sweden)

    V.S. Petrushin

    2016-09-01

    Full Text Available Purpose. Development of innovative electrical engineering discipline «Electric Machines in Mechatronic Systems» in order to improve the training of specialists of electrical engineering specialty. Methodology. The proposed project concerns the educational reforms that promote the intensification of the educational process. Results. The structure of interactive educational and training complex, which is a computer learning tool in the form of software and methodical support, as well as data and knowledge bases and consists of functionally related multimedia learning systems, interactive learning, automated control of the learning process. Originality. To offer online training and research facilities, guidelines for laboratory and computational and graphic works. Practical value. Increase the knowledge of students of educational material related to the discipline of innovation «Electric Machines in Mechatronic Systems».

  11. Annual electricity consumption analysis and forecasting of China based on few observations methods

    International Nuclear Information System (INIS)

    Meng Ming; Niu Dongxiao

    2011-01-01

    The annual electricity consumption analysis and forecasting of China is one of the important bases of management decision making for power generation groups as well as power policy adjusting for government. The socioeconomic actuality could not offer adequate observations with perfect statistic characters. The partial least squares method is applied to get a linear equation. It could quantificational simulate the relationship between the electricity consumption and its factors. The variables importance analysis method is further adopted to distinguish the explanatory power of all relative factors. The foremost importance of production and consumption in rural area shows that the development of this area should account more for the increasing of electricity consumption. The less explanatory power of the gross domestic product of tertiary industry means the gigantic potential in electricity consumption for the future several years. At last, it calculates the contributions of observations. The results show that the unusual development of real estate and relative industry has affected the usual electricity consumption mode. With the clear away of price bubble in real estate, the increasing speed of electricity consumption will slow down in the recent years.

  12. Annual electricity consumption analysis and forecasting of China based on few observations methods

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Ming; Niu, Dongxiao [School of Business Administration, North China Electric Power University, 071003 Baoding (China)

    2011-02-15

    The annual electricity consumption analysis and forecasting of China is one of the important bases of management decision making for power generation groups as well as power policy adjusting for government. The socioeconomic actuality could not offer adequate observations with perfect statistic characters. The partial least squares method is applied to get a linear equation. It could quantificational simulate the relationship between the electricity consumption and its factors. The variables importance analysis method is further adopted to distinguish the explanatory power of all relative factors. The foremost importance of production and consumption in rural area shows that the development of this area should account more for the increasing of electricity consumption. The less explanatory power of the gross domestic product of tertiary industry means the gigantic potential in electricity consumption for the future several years. At last, it calculates the contributions of observations. The results show that the unusual development of real estate and relative industry has affected the usual electricity consumption mode. With the clear away of price bubble in real estate, the increasing speed of electricity consumption will slow down in the recent years. (author)

  13. Annual electricity consumption analysis and forecasting of China based on few observations methods

    Energy Technology Data Exchange (ETDEWEB)

    Meng Ming, E-mail: ncepumm@126.co [School of Business Administration, North China Electric Power University, 071003 Baoding (China); Niu Dongxiao [School of Business Administration, North China Electric Power University, 071003 Baoding (China)

    2011-02-15

    The annual electricity consumption analysis and forecasting of China is one of the important bases of management decision making for power generation groups as well as power policy adjusting for government. The socioeconomic actuality could not offer adequate observations with perfect statistic characters. The partial least squares method is applied to get a linear equation. It could quantificational simulate the relationship between the electricity consumption and its factors. The variables importance analysis method is further adopted to distinguish the explanatory power of all relative factors. The foremost importance of production and consumption in rural area shows that the development of this area should account more for the increasing of electricity consumption. The less explanatory power of the gross domestic product of tertiary industry means the gigantic potential in electricity consumption for the future several years. At last, it calculates the contributions of observations. The results show that the unusual development of real estate and relative industry has affected the usual electricity consumption mode. With the clear away of price bubble in real estate, the increasing speed of electricity consumption will slow down in the recent years.

  14. Methods of qualifying electrical cabinets for the load case earthquake

    International Nuclear Information System (INIS)

    Henkel, F.-O.; Kennerknecht, H.; Haefeli, T.; Jorgensen, F.

    2005-01-01

    With the qualification of electrical system cabinets for the load case earthquake it is differentiated between the two objectives: a) stability of the cabinet, and b) functionality of the built-in electrical modules during and after the earthquake. There are three methods to attain these goals: analyses, tests and proof by analogy. A common method is the shaking of a complete cabinet on a shaking table, with the advantage that stability and functionality can be proved at the same time, but with the disadvantage that quite expensive test equipment, especially a multi-axle shaking table, is necessary and that generally a cabinet which was proved for SSE is pre-affected and thus may not be incorporated into the plant offhand, i.e. the extreme example would be that the cabinet must be built twice. As a rule, analyses are currently carried out by means of Finite-Element-Models of the supporting structure with consideration of the electrical components at least with their masses. This analysis can prove the stability and pursue the excitation until the anchoring point of the electrical components (Henkel et al., 1987). The combination of the aforementioned two methods often constitutes the best way. The stability of the cabinet is proved by calculations, the functionality of the safety-relevant modules by tests. Once tested, modules identical in construction can be used for cabinets without further testing for earthquakes of similar or lower levels. Proof by analogy is possible only if tests or analyses of similar cabinets were done in advance. By means of the comparison of supporting structure, mass allocation and distribution, level and shape of the earthquake excitation it can be shown that the cabinet planned is covered by cabinets already tested or analysed (Katona et al., 1995). All facets of the various methods with advantages and disadvantages are discussed and explained on the basis of numerous examples. (authors)

  15. Electrical impedance tomography spectroscopy method for characterising particles in solid-liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yanlin [Department of Thermal Energy Engineering, College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, 102249 (China); Wang, Mi [Institute of Particle Science and Engineering, School of Process, Environmental and Materials Engineering, University of Leeds, Leeds LS2 9JT (China); Yao, Jun [School of Energy Research, Xiamen University, Xiamen 361005 (China)

    2014-04-11

    Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases system involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles

  16. Progress in electrical impedance imaging of binary media: 1: Analytical and numerical methods

    International Nuclear Information System (INIS)

    Ovacik, Levent; Lin Jentai; Jones, Owen C.

    1998-01-01

    This is the first of two papers summarizing the use of electrical impedance excitation/measurement for producing cross sectional images of the distribution of insulating media imbedded in conducting media. This computed tomographic approach finds the distribution of electrical properties of an electric field which minimizes in the least squares sense the difference between measured and computed boundary response to excitation. In this paper we briefly review the basic analytical methods developed for this system. We then extend these methods to three dimensions, add a method for preconditioning voltages for error correction, describe methods for optimizing the resolution of a target by providing optimal excitation patterns and then describe the overall numerical sensitivity. The second paper then demonstrates the ability of this system to image multiple, separate, differently-sized two-dimensional or three-dimensional targets with demonstrated linear sensitivity of over 30:1 with maximum possible linear sensitivity of one part in 1300 based on our ability to distinguish variations from a homogeneous background. (author)

  17. Investigation by perturbative and analytical method of electronic properties of square quantum well under electric field

    Directory of Open Access Journals (Sweden)

    Mustafa Kemal BAHAR

    2010-06-01

    Full Text Available In this study, the effects of applied electric field on the isolated square quantum well was investigated by analytic and perturbative method. The energy eigen values and wave functions in quantum well were found by perturbative method. Later, the electric field effects were investigated by analytic method, the results of perturbative and analytic method were compared. As well as both of results fit with each other, it was observed that externally applied electric field changed importantly electronic properties of the system.

  18. Electric field control methods for foil coils in high-voltage linear actuators

    NARCIS (Netherlands)

    Beek, van T.A.; Jansen, J.W.; Lomonova, E.A.

    2015-01-01

    This paper describes multiple electric field control methods for foil coils in high-voltage coreless linear actuators. The field control methods are evaluated using 2-D and 3-D boundary element methods. A comparison is presented between the field control methods and their ability to mitigate

  19. Method and apparatus for debris mitigation for an electrical discharge source

    Science.gov (United States)

    Klebanoff, Leonard E [San Clemente, CA; Rader, Daniel J [Albuquerque, NM; Silfvast, William T [Helena, CA

    2006-01-24

    Method and apparatus for mitigating the transport of debris generated and dispersed from electric discharge sources by thermophoretic and electrostatic deposition. A member is positioned adjacent the front electrode of an electric discharge source and used to establish a temperature difference between it and the front electrode. By flowing a gas between the member and the front electrode a temperature gradient is established that can be used for thermophoretic deposition of particulate debris on either the member or front electrode depending upon the direction of the thermal gradient. Establishing an electric field between the member and front electrode can aid in particle deposition by electrostatic deposition.

  20. FINITE VOLUME METHOD FOR SOLVING THREE-DIMENSIONAL ELECTRIC FIELD DISTRIBUTION

    Directory of Open Access Journals (Sweden)

    Paţiuc V.I.

    2011-04-01

    Full Text Available The paper examines a new approach to finite volume method which is used to calculate the electric field spatially homogeneous three-dimensional environment. It is formulated the problem Dirihle with building of the computational grid on base of space partition, which is known as Delone triangulation with the use of Voronoi cells. It is proposed numerical algorithm for calculating the potential and electric field strength in the space formed by a cylinder placed in the air. It is developed algorithm and software which were for the case, when the potential on the inner surface of the cylinder has been assigned and on the outer surface and the bottom of cylinder it was assigned zero potential. There are presented results of calculations of distribution in the potential space and electric field strength.

  1. Voltage current characteristics of type III superconductors

    Science.gov (United States)

    Dorofejev, G. L.; Imenitov, A. B.; Klimenko, E. Yu.

    1980-06-01

    An adequate description of voltage-current characteristics is important in order to understand the nature of high critical current for the electrodynamic construction of type-III superconductors and for commercial superconductor specification. Homogenious monofilament and multifilament Nb-Ti, Nb-Zr, Nb 3Sn wires were investigated in different ranges of magnetic field, temperature and current. The longitudinal electric field for homogenious wires may be described by E=J ρnexp- T c/T 0+ T/T 0+ B/B 0+ J/J 0, where To, Bo, Jo are the increasing parameters, which depend weakly on B and T, of the electric field. The shape of the voltage-current characteristics of multifilament wires, and the parameter's dependence on temperature and magnetic field may be explained qualitatively by the longitudinal heterogeneous nature of the filaments. A method of attaining the complete specification of the wire's electro-physical properties is proposed. It includes the traditional description of a critical surface (ie the surface corresponding to a certain conventional effective resistivity in T, B, J - space) and a description of any increasing parameter that depends on B and T.

  2. Electrically Injected UV-Visible Nanowire Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Wang, George T.; Li, Changyi; Li, Qiming; Liu, Sheng; Wright, Jeremy Benjamin; Brener, Igal; Luk, Ting -Shan; Chow, Weng W.; Leung, Benjamin; Figiel, Jeffrey J.; Koleske, Daniel D.; Lu, Tzu-Ming

    2015-09-01

    There is strong interest in minimizing the volume of lasers to enable ultracompact, low-power, coherent light sources. Nanowires represent an ideal candidate for such nanolasers as stand-alone optical cavities and gain media, and optically pumped nanowire lasing has been demonstrated in several semiconductor systems. Electrically injected nanowire lasers are needed to realize actual working devices but have been elusive due to limitations of current methods to address the requirement for nanowire device heterostructures with high material quality, controlled doping and geometry, low optical loss, and efficient carrier injection. In this project we proposed to demonstrate electrically injected single nanowire lasers emitting in the important UV to visible wavelengths. Our approach to simultaneously address these challenges is based on high quality III-nitride nanowire device heterostructures with precisely controlled geometries and strong gain and mode confinement to minimize lasing thresholds, enabled by a unique top-down nanowire fabrication technique.

  3. Simulation of electrically driven jet using Chebyshev collocation method

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The model of electrically driven jet is governed by a series of quasi 1D dimensionless partial differential equations(PDEs).Following the method of lines,the Chebyshev collocation method is employed to discretize the PDEs and obtain a system of differential-algebraic equations(DAEs).By differentiating constrains in DAEs twice,the system is transformed into a set of ordinary differential equations(ODEs) with invariants.Then the implicit differential equations solver "ddaskr" is used to solve the ODEs and ...

  4. New Tunneling Features in Polar III-Nitride Resonant Tunneling Diodes

    Directory of Open Access Journals (Sweden)

    Jimy Encomendero

    2017-10-01

    Full Text Available For the past two decades, repeatable resonant tunneling transport of electrons in III-nitride double barrier heterostructures has remained elusive at room temperature. In this work we theoretically and experimentally study III-nitride double-barrier resonant tunneling diodes (RTDs, the quantum transport characteristics of which exhibit new features that are unexplainable using existing semiconductor theory. The repeatable and robust resonant transport in our devices enables us to track the origin of these features to the broken inversion symmetry in the uniaxial crystal structure, which generates built-in spontaneous and piezoelectric polarization fields. Resonant tunneling transport enabled by the ground state as well as by the first excited state is demonstrated for the first time over a wide temperature window in planar III-nitride RTDs. An analytical transport model for polar resonant tunneling heterostructures is introduced for the first time, showing a good quantitative agreement with experimental data. From this model we realize that tunneling transport is an extremely sensitive measure of the built-in polarization fields. Since such electric fields play a crucial role in the design of electronic and photonic devices, but are difficult to measure, our work provides a completely new method to accurately determine their magnitude for the entire class of polar heterostructures.

  5. Method for evaluating leaching from LSA-III material

    International Nuclear Information System (INIS)

    Abe, H.; Satoh, K.; Ozaki, S.; Watabe, N.; Iida, T.; Akamatsu, H.

    1989-01-01

    The IAEA transport regulations are scheduled to be introduced in Japan. New regulations are supposed to be set forth for low specific activity (LSA) material and industrial packaging (IP) as solidified concentrated waste water should correspond to the LSA material. Solidified concentrated waste water should be transported in accordance with the new transport regulations which reflect the IAEA transport regulations. As one of the regulations for LSA material, the leaching test for LSA-III materials states that the radioactive loss due to leaching without the packaging should not exceed 0.1 A 2 when left in the water for 7 days. This test method is called Transport regulations hereafter. Since the test had not been conducted in Japan before now, there was no available data. Consequently, it is necessary to make an assessment on whether the current solidified concentrated waste water can satisfy the leaching amount of radioactive nuclide specified in the IAEA transport regulations. If the test is performed in accordance with the IAEA transport regulations, however, it is necessary to measure the amount of radioactive nuclide actually leached from the solidified concentrated waste water. Since the solidified concentrated waste water is put in a drum cam, it is necessary to prepare large-scale hot test equipment. In this study, therefore, the leaching test was conducted on the solidified concentrated waste water to propose the means of a leaching assessment which can be conducted with ordinary equipment to evaluate the leaching for assessment of the adaptability to IAEA transport regulations. In addition, the leaching test was performed in accordance with the IAEA method to examine the co-relation between the transport regulations and the IAEA method. Many test results have been reported for the IAEA method in Japan, which will be detailed later on

  6. Electric field analysis of extra high voltage (EHV) underground cables using finite element method

    DEFF Research Database (Denmark)

    Kumar, Mantosh; Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar

    2017-01-01

    used for the insulator due electrical, thermal or environmental stress. Most of these problems are related to the electric field stress on the insulation of the underground cables. The objective of the electric field analysis by using different numerical techniques is to find electric field stress...... electric field stress and other parameters of EHV underground cables with given boundary conditions using 2-D electric field analysis software package (IES-ELECTRO module) which is based on the finite element method (FEM).......Transmission and Distribution of electric power through underground cables is a viable alternative to overhead lines, particularly in residential or highly populated areas. The electrical stresses are consequences of regular voltages and over voltages and the thermal stresses are related to heat...

  7. Application of two electrical methods for the rapid assessment of freezing resistance in Salix epichloro

    Energy Technology Data Exchange (ETDEWEB)

    Tsarouhas, V.; Kenney, W.A.; Zsuffa, L. [University of Toronto, Ontario (Canada). Faculty of Forestry

    2000-09-01

    The importance of early selection of frost-resistant Salix clones makes it desirable to select a rapid and accurate screening method for assessing freezing resistance among several genotypes. Two electrical methods, stem electrical impedance to 1 and 10 khz alternating current, and electrolyte leakage of leaf tissue, were evaluated for detecting freezing resistance on three North America Salix epichloro Michx., clones after subjecting them to five different freezing temperatures (-1, -2, -3, -4, and -5 deg C). Differences in the electrical impedance to 1 and 10 kHz, and the ratio of the impedance at the two frequencies (low/high) before and after the freezing treatment (DZ{sub low}, DZ{sub high}, and DZ{sub ratio}, respectively) were estimated. Electrolyte leakage was expressed as relative conductivity (RC{sub t}) and index of injury (IDX{sub t}). Results from the two methods, obtained two days after the freezing stress, showed that both electrical methods were able to detect freezing injury in S. eriocephala. However, the electrolyte leakage method detected injury in more levels of freezing stress (-3, -4, and -5 deg C) than the impedance (-4, and -5 deg C), it assessed clonal differences in S. eriocephala freezing resistance, and it was best suited to correlate electrical methods with the visual assessed freezing injury. No significant impedance or leakage changes were found after the -1 and -2 deg C freezing temperatures. (author)

  8. A holographic method for investigating cylindrical symmetry plasmas resulting from electric discharges

    International Nuclear Information System (INIS)

    Rosu, N.; Ralea, M.; Foca, M.; Iova, I.

    1992-01-01

    A new method based on holographic interferometry in real time with reference fringes for diagnosing gas electric discharges in cylindrical symmetry tubes is presented. A method for obtaining and quantitatively investigating interferograms obtained with a video camera is described. By studying the resulting images frame by frame and introducing the measurements into an adequate computer programme one gets a graphical recording of the radial distribution of the charged particle concentration in the plasma in any region of the tube at a given time, as well as their axial distribution. The real time evolution of certain phenomena occurring in the discharge tube can also be determined by this non-destructive method. The method is used for electric discharges in Ar at average pressures in a discharge tube with hollow cathode effect. (Author)

  9. Electric power quality analysis methods. Application to voltage dips and harmonic disturbances

    International Nuclear Information System (INIS)

    Vanya, Ignatova

    2006-10-01

    The power quality concerns all the actors in the energy domains, that they are network administrators, suppliers, producers, or consumers of electricity. The research work presented in this PhD thesis is situated in the field of the power quality monitoring. Its objective is to introduce new techniques for analysis of power quality problems. There are different methods designed for the analysis of the power quality disturbances. This method reaches very good performances in the voltage dips analysis, as it allows segmenting, classifying and characterising these power quality disturbances. The periodic systems method allows the theoretical study of the generation and the propagation of harmonic disturbances in the network. Finally, the statistical matrix method has the objective to represent statistically electrical signals without loss of important information. (author)

  10. Electrical motor/generator drive apparatus and method

    Science.gov (United States)

    Su, Gui Jia

    2013-02-12

    The present disclosure includes electrical motor/generator drive systems and methods that significantly reduce inverter direct-current (DC) bus ripple currents and thus the volume and cost of a capacitor. The drive methodology is based on a segmented drive system that does not add switches or passive components but involves reconfiguring inverter switches and motor stator winding connections in a way that allows the formation of multiple, independent drive units and the use of simple alternated switching and optimized Pulse Width Modulation (PWM) schemes to eliminate or significantly reduce the capacitor ripple current.

  11. Acousto-optic modulation of III-V semiconductor multiple quantum wells

    International Nuclear Information System (INIS)

    Smith, D.L.; Kogan, S.M.; Ruden, P.P.; Mailhiot, C.

    1996-01-01

    We present an analysis of the effect of surface acoustic waves (SAW close-quote s) on the optical properties of III-V semiconductor multiple quantum wells (MQW close-quote s). Modulation spectra at the fundamental and second harmonic of the SAW frequency are presented. The SAW modulates the optical properties of the MQW primarily by changing optical transition energies. The SAW generates both strains, which modulate the transition energies by deformation potential effects, and electric fields, which modulate the transition energies by the quantum confined Stark effect. We find that modulation of the transition energies by strain effects is usually more important than by electric-field effects. If large static electric fields occur in the MQW, the SAW-generated electric field can mix with the static field to give optical modulation, which is comparable in magnitude to modulation from the deformation potential effect. If there are no large static electric fields, modulation by the SAW-generated fields is negligible. A large static electric field distributes oscillator strength among the various optical transitions so that no single transition is as strong as the primary allowed transitions without a static electric field. To achieve the maximum modulation for fixed SAW parameters, it is best to modulate a strong optical transition. Thus optimum modulation occurs when there are no large static electric fields present and that modulation is primarily from deformation potential effects. We specifically consider Ga x In 1-x As/Ga x Al 1-x As MQW close-quote s grown on (100) and (111) oriented substrates, but our general conclusions apply to other type I MQW close-quote s fabricated from III-V semiconductors. copyright 1996 The American Physical Society

  12. Recent Progress on the Factorization Method for Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Bastian Harrach

    2013-01-01

    method was introduced by Kirsch for inverse scattering problems and extended to electrical impedance tomography (EIT by Brühl and Hanke. Since these pioneering works, substantial progress has been made on the theoretical foundations of the method. The necessary assumptions have been weakened, and the proofs have been considerably simplified. In this work, we aim to summarize this progress and present a state-of-the-art formulation of the Factorization Method for EIT with continuous data. In particular, we formulate the method for general piecewise analytic conductivities and give short and self-contained proofs.

  13. System and method employing a self-organizing map load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

    2014-06-17

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

  14. Enhancement of the fluorescence of the samarium (III) complex by gadolinium (III)

    International Nuclear Information System (INIS)

    Yun-Xiang, C.; Zhang-Hua, L.

    1988-01-01

    The increase in sensitivity and selectivity of reactions in which colored species are formed by the addition of different metal ions is an area of research that has recently been developed. This phenomenon, which is sometimes called cocolaration effect, has been explained by the formation of mixed metal complex. The authors found an analogous phenomenon of reactions forming fluorescent complexes. The complexes of Sm(III)-thenoyltrifluoroacetone (TTA)-phenanthroline (Phen)-Triton-X-100 (TX-100) and Gd(III) (or La(III), Lu(III) and Y(III))-TTA-Phen-TX-100 had practically no fluorescence separately. Instead, a fluorescence-enhancement phenomenon caused by adding Gd or La, Lu and Y ions to the system was observed for the first time. The intensity of the enhanced fluorescence of Sm(III) complex was increased in the following order: La< Y< Lu< Gd. By analogy with cocoloration effect, the authors call this new fluorescence-enhancement phenomenon the co-fluorescence effect. The object of this work was to study the enhancement effect of Gd(III) on the fluorescence of the Sm(III)-TTA-Phen-TX-100 system. The recommended fluorimetric method has been applied to the determination of trace amounts of samarium in ytterbium oxide with satisfactory results. A general reaction mechanism for the system studied was proposed

  15. A proposed method of measuring the electric-dipole moment of the neutron by ultracold neutron interferometry

    International Nuclear Information System (INIS)

    Freedman, M.S.; Peshkin, M.; Ringo, G.R.; Dombeck, T.W.

    1989-08-01

    The use of an ultracold neutron interferometer incorporating an electrostatic accelerator having a strong electric field gradient to accelerate neutrons by their possible electric dipole moment is proposed as a method of measuring the neutron electric dipole moment. The method appears to have the possibility of extending the sensitivity of the measurement by several orders of magnitude, perhaps to 10 -30 e-cm. 9 refs., 3 figs

  16. Hybrid ARIMAX quantile regression method for forecasting short term electricity consumption in east java

    Science.gov (United States)

    Prastuti, M.; Suhartono; Salehah, NA

    2018-04-01

    The need for energy supply, especially for electricity in Indonesia has been increasing in the last past years. Furthermore, the high electricity usage by people at different times leads to the occurrence of heteroscedasticity issue. Estimate the electricity supply that could fulfilled the community’s need is very important, but the heteroscedasticity issue often made electricity forecasting hard to be done. An accurate forecast of electricity consumptions is one of the key challenges for energy provider to make better resources and service planning and also take control actions in order to balance the electricity supply and demand for community. In this paper, hybrid ARIMAX Quantile Regression (ARIMAX-QR) approach was proposed to predict the short-term electricity consumption in East Java. This method will also be compared to time series regression using RMSE, MAPE, and MdAPE criteria. The data used in this research was the electricity consumption per half-an-hour data during the period of September 2015 to April 2016. The results show that the proposed approach can be a competitive alternative to forecast short-term electricity in East Java. ARIMAX-QR using lag values and dummy variables as predictors yield more accurate prediction in both in-sample and out-sample data. Moreover, both time series regression and ARIMAX-QR methods with addition of lag values as predictor could capture accurately the patterns in the data. Hence, it produces better predictions compared to the models that not use additional lag variables.

  17. Power control apparatus and methods for electric vehicles

    Science.gov (United States)

    Gadh, Rajit; Chung, Ching-Yen; Chu, Chi-Cheng; Qiu, Li

    2016-03-22

    Electric vehicle (EV) charging apparatus and methods are described which allow the sharing of charge current between multiple vehicles connected to a single source of charging energy. In addition, this charge sharing can be performed in a grid-friendly manner by lowering current supplied to EVs when necessary in order to satisfy the needs of the grid, or building operator. The apparatus and methods can be integrated into charging stations or can be implemented with a middle-man approach in which a multiple EV charging box, which includes an EV emulator and multiple pilot signal generation circuits, is coupled to a single EV charge station.

  18. Basic study on electrically stimulated luminescence (ESL) as a dosimetry and dating method

    International Nuclear Information System (INIS)

    Sato, H.; Yamanaka, C.; Ikeya, M.

    2003-01-01

    Electrically stimulated luminescence (ESL) of calcium carbonate has been studied for application as dosimetry and dating. A powdered calcium carbonate was sandwiched by electrodes, which supplied electric field. Luminescence and surface current through a powdered sample were measured using a photomultiplier and a digital multimeter, respectively. A linear dependence of ESL on the absorbed dose by γ-rays was found when the applied voltage was below the breakdown threshold. Reciprocal electric charges through the sample had also linear relation with the absorbed dose. We propose that the luminescence and electric charge under intense electric field in calcium carbonate become new methods for dosimetry and dating on the basis of the surface defects of the calcium carbonate grains produced by the irradiation of γ-rays

  19. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  20. A new normalization method based on electrical field lines for electrical capacitance tomography

    International Nuclear Information System (INIS)

    Zhang, L F; Wang, H X

    2009-01-01

    Electrical capacitance tomography (ECT) is considered to be one of the most promising process tomography techniques. The image reconstruction for ECT is an inverse problem to find the spatially distributed permittivities in a pipe. Usually, the capacitance measurements obtained from the ECT system are normalized at the high and low permittivity for image reconstruction. The parallel normalization model is commonly used during the normalization process, which assumes the distribution of materials in parallel. Thus, the normalized capacitance is a linear function of measured capacitance. A recently used model is a series normalization model which results in the normalized capacitance as a nonlinear function of measured capacitance. The newest presented model is based on electrical field centre lines (EFCL), and is a mixture of two normalization models. The multi-threshold method of this model is presented in this paper. The sensitivity matrices based on different normalization models were obtained, and image reconstruction was carried out accordingly. Simulation results indicate that reconstructed images with higher quality can be obtained based on the presented model

  1. Analysis and forecast of electrical distribution system materials. Final report. Volume III. Appendix

    Energy Technology Data Exchange (ETDEWEB)

    Love, C G

    1976-08-23

    These appendixes are referenced in Volume II of this report. They contain the detailed electrical distribution equipment requirements and input material requirements forecasts. Forecasts are given for three electric energy usage scenarios. Also included are data on worldwide reserves and demand for 30 raw materials required for the manufacture of electrical distribution equipment.

  2. More Electricity. Methodical survey of existing plants; Mer El. Metodisk genomgaang av befintliga anlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Baafaelt, Martin [Carl Bro Energikonsult AB, Malmoe (Sweden); Ifwer, Karin; Svensson, Niclas; Oehrstroem, Anna [AaF-Process AB, Stockholm (Sweden); Johansson, Inge [S.E.P. Scandinavian Energy Project AB, Goeteborg (Sweden)

    2006-11-15

    The interest in production of electricity has increased the last years as a consequence of the increased price. A high production of electricity is of interest for all kinds of CHP-plants. For large biofuel fired CHP-plants typical electrical efficiency is 35 %, for incineration plants the electrical efficiency is about 28 %. A number of reasons why it is not higher, for example corrosion, fouling, erosion, limited and varying need for heat, flue gas condensation etc, exist. A number of these reasons have earlier been studied in different Vaermeforsk reports. The results from these studies give to some extent solutions and understanding for how the production of electricity can be increased. There is however no report that has the overall picture of what actions are realistic, most cost effective, what areas need more research and gives the most benefit of allocated funds. The aim of this report is to identify the technical limitations and propose measures for increased electricity production at CHP-plants using biofuel and waste. A method for identification of the most suitable actions for each plant is also presented. The idea is to take every conceivable factor that affects electricity production into consideration and to be able to make a relevant comparison of the factors. This report doesn't take new solutions/measures and means of control into consideration. The method used is called 'Weighted Sum Method'. Every action is assessed in the means of different criteria as for example how it affects the environment, if it is profitable, if it means more maintenance etc. An extensive checklist for different conceivable measures for increased electricity production has been created. The checklist includes measures from the fuel storage to the chimney and makes a good guidance when making a review of a biofuel or incineration CHP-plant. Some of the measures can be eliminated immediately at review since they not are applicable or have already been done

  3. Electrical connection for aluminium conductors in automotive applications : Prestudy of available solutions for electrical connection methods of aluminium cables

    OpenAIRE

    Hamedi, Emilia

    2017-01-01

    Due to increasing weight of electrical component and wiring harnesses in a vehicle contrary to the demand of light constructed vehicles as well as the constantly increasing and fluctuating price of copper compared to aluminium’s stable and far lower price, the use of aluminium conductors as an alternative have been promoted.  This thesis work lay theoretical research of the available methods used for electrical connection of aluminium conductors in order to increase the knowledge about the av...

  4. Thermal crosstalk in arrays of III-N-based Lasers

    International Nuclear Information System (INIS)

    Kuc, Maciej; Sarzała, Robert P.; Nakwaski, Włodzimierz

    2013-01-01

    This paper presents a 3D comprehensive thermal-electrical self-consistent model of the continuous-wave (CW) operation of one-dimensional arrays of III-N-based laser diodes at room-temperature (RT). Their performance is mostly limited by thermal processes, in particular by thermal crosstalk between array emitters. Based on data collected from a range of secondary sources, the temperature dependence of the thermal and electrical conductivities of III-N materials used to manufacture nitride-based devices is shown to be a function of the thickness, aluminum mole fractions and Si- and Mg-doping levels of the nitride layers. The impact of substrate width and thickness on increasing the efficiency of heat-flux transport and reducing thermal crosstalk is investigated. As expected, the application of a top-mounted diamond heat spreader was found to have considerable influence on the thermal crosstalk between array emitters, enabling the RT CW operation of laser diode arrays with additional emitters

  5. Mastication noise reduction method for fully implantable hearing aid using piezo-electric sensor.

    Science.gov (United States)

    Na, Sung Dae; Lee, Gihyoun; Wei, Qun; Seong, Ki Woong; Cho, Jin Ho; Kim, Myoung Nam

    2017-07-20

    Fully implantable hearing devices (FIHDs) can be affected by generated biomechanical noise such as mastication noise. To reduce the mastication noise using a piezo-electric sensor, the mastication noise is measured with the piezo-electric sensor, and noise reduction is practiced by the energy difference. For the experiment on mastication noise, a skull model was designed using artificial skull model and a piezo-electric sensor that can measure the vibration signals better than other sensors. A 1 kHz pure-tone sound through a standard speaker was applied to the model while the lower jawbone of the model was moved in a masticatory fashion. The correlation coefficients and signal-to-noise ratio (SNR) before and after application of the proposed method were compared. It was found that the signal-to-noise ratio and correlation coefficients increased by 4.48 dB and 0.45, respectively. The mastication noise is measured by piezo-electric sensor as the mastication noise that occurred during vibration. In addition, the noise was reduced by using the proposed method in conjunction with MATLAB. In order to confirm the performance of the proposed method, the correlation coefficients and signal-to-noise ratio before and after signal processing were calculated. In the future, an implantable microphone for real-time processing will be developed.

  6. Temporal development of cross-neutralization between HTLV-III B and HTLV-III RF in experimentally infected chimpanzees

    NARCIS (Netherlands)

    Goudsmit, J.; Thiriart, C.; Smit, L.; Bruck, C.; Gibbs, C. J.

    1988-01-01

    Sera from chimpanzees inoculated respectively with HTLV-III B, LAV, HTLV-III RF and brain tissue from an AIDS patient were analysed for neutralizing activity by two methods: a cell fusion inhibition test (CFI) using HTLV-III B infected cells as inoculum and CD4+ cells as target and a replication

  7. Progress in Group III nitride semiconductor electronic devices

    International Nuclear Information System (INIS)

    Hao Yue; Zhang Jinfeng; Shen Bo; Liu Xinyu

    2012-01-01

    Recently there has been a rapid domestic development in group III nitride semiconductor electronic materials and devices. This paper reviews the important progress in GaN-based wide bandgap microelectronic materials and devices in the Key Program of the National Natural Science Foundation of China, which focuses on the research of the fundamental physical mechanisms of group III nitride semiconductor electronic materials and devices with the aim to enhance the crystal quality and electric performance of GaN-based electronic materials, develop new GaN heterostructures, and eventually achieve high performance GaN microwave power devices. Some remarkable progresses achieved in the program will be introduced, including those in GaN high electron mobility transistors (HEMTs) and metal—oxide—semiconductor high electron mobility transistors (MOSHEMTs) with novel high-k gate insulators, and material growth, defect analysis and material properties of InAlN/GaN heterostructures and HEMT fabrication, and quantum transport and spintronic properties of GaN-based heterostructures, and high-electric-field electron transport properties of GaN material and GaN Gunn devices used in terahertz sources. (invited papers)

  8. Data-based method for creating electricity use load profiles using large amount of customer-specific hourly measured electricity use data

    International Nuclear Information System (INIS)

    Raesaenen, Teemu; Voukantsis, Dimitrios; Niska, Harri; Karatzas, Kostas; Kolehmainen, Mikko

    2010-01-01

    The recent technological developments monitoring the electricity use of small customers provides with a whole new view to develop electricity distribution systems, customer-specific services and to increase energy efficiency. The analysis of customer load profile and load estimation is an important and popular area of electricity distribution technology and management. In this paper, we present an efficient methodology, based on self-organizing maps (SOM) and clustering methods (K-means and hierarchical clustering), capable of handling large amounts of time-series data in the context of electricity load management research. The proposed methodology was applied on a dataset consisting of hourly measured electricity use data, for 3989 small customers located in Northern-Savo, Finland. Information for the hourly electricity use, for a large numbers of small customers, has been made available only recently. Therefore, this paper presents the first results of making use of these data. The individual customers were classified into user groups based on their electricity use profile. On this basis, new, data-based load curves were calculated for each of these user groups. The new user groups as well as the new-estimated load curves were compared with the existing ones, which were calculated by the electricity company, on the basis of a customer classification scheme and their annual demand for electricity. The index of agreement statistics were used to quantify the agreement between the estimated and observed electricity use. The results indicate that there is a clear improvement when using data-based estimations, while the new-estimated load curves can be utilized directly by existing electricity power systems for more accurate load estimates.

  9. Data-based method for creating electricity use load profiles using large amount of customer-specific hourly measured electricity use data

    Energy Technology Data Exchange (ETDEWEB)

    Raesaenen, Teemu; Niska, Harri; Kolehmainen, Mikko [Department of Environmental Sciences, University of Eastern Finland P.O. Box 1627, FIN-70211 Kuopio (Finland); Voukantsis, Dimitrios; Karatzas, Kostas [Department of Mechanical Engineering, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2010-11-15

    The recent technological developments monitoring the electricity use of small customers provides with a whole new view to develop electricity distribution systems, customer-specific services and to increase energy efficiency. The analysis of customer load profile and load estimation is an important and popular area of electricity distribution technology and management. In this paper, we present an efficient methodology, based on self-organizing maps (SOM) and clustering methods (K-means and hierarchical clustering), capable of handling large amounts of time-series data in the context of electricity load management research. The proposed methodology was applied on a dataset consisting of hourly measured electricity use data, for 3989 small customers located in Northern-Savo, Finland. Information for the hourly electricity use, for a large numbers of small customers, has been made available only recently. Therefore, this paper presents the first results of making use of these data. The individual customers were classified into user groups based on their electricity use profile. On this basis, new, data-based load curves were calculated for each of these user groups. The new user groups as well as the new-estimated load curves were compared with the existing ones, which were calculated by the electricity company, on the basis of a customer classification scheme and their annual demand for electricity. The index of agreement statistics were used to quantify the agreement between the estimated and observed electricity use. The results indicate that there is a clear improvement when using data-based estimations, while the new-estimated load curves can be utilized directly by existing electricity power systems for more accurate load estimates. (author)

  10. Separation of valence forms of chromium(III) and chromium(VI) by coprecipitation with iron(III) hydroxide

    International Nuclear Information System (INIS)

    Nazirmadov, B.; Khamidov, B.O.; Egorova, L.A.

    1989-01-01

    The sorption of 9.62·10 -5 M of Cr (III) and Cr (VI) with iron hydroxide in 1 M potassium nitrate and potassium chloride was investigated in relation to the pH of the medium. Experimental data on the sorption of chromium(III) and chromium(VI) with iron(III) hydroxide made it possible to determine the region of practically complete concentration of Cr (III) and Cr (VI) (pH = 3-6.5). The results from spectrophotometric investigations, calculated data on the distribution of the hydroxocationic forms of chromium(III) and the anions of chromium(IV), and their sorption by iron-(III) hydroxide made it possible to characterize the sorbability of the cationic and anionic forms of chromium in various degrees of oxidation. On this basis a method was developed for the separation of chromium(III) and chromium(VI) by coprecipitation on iron(III) hydroxide and their separation from the iron(III) hydroxide support

  11. 3D electrical conductivity tomography of volcanoes

    Science.gov (United States)

    Soueid Ahmed, A.; Revil, A.; Byrdina, S.; Coperey, A.; Gailler, L.; Grobbe, N.; Viveiros, F.; Silva, C.; Jougnot, D.; Ghorbani, A.; Hogg, C.; Kiyan, D.; Rath, V.; Heap, M. J.; Grandis, H.; Humaida, H.

    2018-05-01

    Electrical conductivity tomography is a well-established galvanometric method for imaging the subsurface electrical conductivity distribution. We characterize the conductivity distribution of a set of volcanic structures that are different in terms of activity and morphology. For that purpose, we developed a large-scale inversion code named ECT-3D aimed at handling complex topographical effects like those encountered in volcanic areas. In addition, ECT-3D offers the possibility of using as input data the two components of the electrical field recorded at independent stations. Without prior information, a Gauss-Newton method with roughness constraints is used to solve the inverse problem. The roughening operator used to impose constraints is computed on unstructured tetrahedral elements to map complex geometries. We first benchmark ECT-3D on two synthetic tests. A first test using the topography of Mt. St Helens volcano (Washington, USA) demonstrates that we can successfully reconstruct the electrical conductivity field of an edifice marked by a strong topography and strong variations in the resistivity distribution. A second case study is used to demonstrate the versatility of the code in using the two components of the electrical field recorded on independent stations along the ground surface. Then, we apply our code to real data sets recorded at (i) a thermally active area of Yellowstone caldera (Wyoming, USA), (ii) a monogenetic dome on Furnas volcano (the Azores, Portugal), and (iii) the upper portion of the caldera of Kīlauea (Hawai'i, USA). The tomographies reveal some of the major structures of these volcanoes as well as identifying alteration associated with high surface conductivities. We also review the petrophysics underlying the interpretation of the electrical conductivity of fresh and altered volcanic rocks and molten rocks to show that electrical conductivity tomography cannot be used as a stand-alone technique due to the non-uniqueness in

  12. III-N Wide Bandgap Deep-Ultraviolet Lasers and Photodetectors

    KAUST Repository

    Detchprohm, T.

    2016-11-05

    The III-N wide-bandgap alloys in the AlInGaN system have many important and unique electrical and optical properties which have been exploited to develop deep-ultraviolet (DUV) optical devices operating at wavelengths < 300 nm, including light-emitting diodes, optically pumped lasers, and photodetectors. In this chapter, we review some aspects of the development and current state of the art of these DUV materials and devices. We describe the growth of III-N materials in the UV region by metalorganic chemical vapor deposition as well as the properties of epitaxial layers and heterostructure devices. In addition, we discuss the simulation and design of DUV laser diodes, the processing of III-N optical devices, and the description of the current state of the art of DUV lasers and photodetectors.

  13. Method and system for early detection of incipient faults in electric motors

    Science.gov (United States)

    Parlos, Alexander G; Kim, Kyusung

    2003-07-08

    A method and system for early detection of incipient faults in an electric motor are disclosed. First, current and voltage values for one or more phases of the electric motor are measured during motor operations. A set of current predictions is then determined via a neural network-based current predictor based on the measured voltage values and an estimate of motor speed values of the electric motor. Next, a set of residuals is generated by combining the set of current predictions with the measured current values. A set of fault indicators is subsequently computed from the set of residuals and the measured current values. Finally, a determination is made as to whether or not there is an incipient electrical, mechanical, and/or electromechanical fault occurring based on the comparison result of the set of fault indicators and a set of predetermined baseline values.

  14. Electrical Versus Optical: Comparing Methods for Detecting Terahertz Radiation Using Neon Lamps

    Science.gov (United States)

    Slocombe, L. L.; Lewis, R. A.

    2018-05-01

    Terahertz radiation impinging on a lit neon tube causes additional ionization of the encapsulated gas. As a result, the electrical current flowing between the electrodes increases and the glow discharge in the tube brightens. These dual phenomena suggest two distinct modes of terahertz sensing. The electrical mode simply involves measuring the electrical current. The optical mode involves monitoring the brightness of the weakly ionized plasma glow discharge. Here, we directly compare the two detection modes under identical experimental conditions. We measure 0.1-THz radiation modulated at frequencies in the range 0.1-10 kHz, for lamp currents in the range 1-10 mA. We find that electrical detection provides a superior signal-to-noise ratio while optical detection has a faster response. Either method serves as the basis of a compact, robust, and inexpensive room-temperature detector of terahertz radiation.

  15. An integrated approach for facilities planning by ELECTRE method

    Science.gov (United States)

    Elbishari, E. M. Y.; Hazza, M. H. F. Al; Adesta, E. Y. T.; Rahman, Nur Salihah Binti Abdul

    2018-01-01

    Facility planning is concerned with the design, layout, and accommodation of people, machines and activities of a system. Most of the researchers try to investigate the production area layout and the related facilities. However, few of them try to investigate the relationship between the production space and its relationship with service departments. The aim of this research to is to integrate different approaches in order to evaluate, analyse and select the best facilities planning method that able to explain the relationship between the production area and other supporting departments and its effect on human efforts. To achieve the objective of this research two different approaches have been integrated: Apple’s layout procedure as one of the effective tools in planning factories, ELECTRE method as one of the Multi Criteria Decision Making methods (MCDM) to minimize the risk of getting poor facilities planning. Dalia industries have been selected as a case study to implement our integration the factory have been divided two main different area: the whole facility (layout A), and the manufacturing area (layout B). This article will be concerned with the manufacturing area layout (Layout B). After analysing the data gathered, the manufacturing area was divided into 10 activities. There are five factors that the alternative were compared upon which are: Inter department satisfactory level, total distance travelled for workers, total distance travelled for the product, total time travelled for the workers, and total time travelled for the product. Three different layout alternatives have been developed in addition to the original layouts. Apple’s layout procedure was used to study and evaluate the different alternatives layouts, the study and evaluation of the layouts was done by calculating scores for each of the factors. After obtaining the scores from evaluating the layouts, ELECTRE method was used to compare the proposed alternatives with each other and with

  16. A new turn-on fluorimetric method for the rapid speciation of Cr(III)/Cr(VI) species in tea samples with rhodamine-based fluorescent reagent

    Science.gov (United States)

    Özyol, Esra; Saçmacı, Şerife; Saçmacı, Mustafa; Ülgen, Ahmet

    2018-02-01

    A new fluorimetric method with rhodamine-based fluorescent agent was developed for the rapid speciation of Cr(III)/Cr(VI) in tea, soil and water samples. The system, which utilizes a fluorescent reagent, was used for the first time after synthesis/characterization of 3‧,6‧-bis(diethylamino)-2-{[(1E)-(2,4-dimethoxyphenyl)methylene] amino}spiro[isoindole-1,9‧-xanthen]-3(2H)-one (BDAS). The reagent responds instantaneously at room temperature in a 1:1 stoichiometric manner to the amount of Cr(III). The selectivity of this system for Cr(III) over other metal ions is remarkably high, and its sensitivity is below 0.01 mg L- 1 in aqueous solutions which enables a simplification without any pretreatment of the real sample. The method has a wide linear range of 0.1-10 mg L- 1 and a detection limit of 0.15 μg L- 1 for Cr(III) while the relative standard deviation was 0.1% for 0.1 mg L- 1 Cr(III) concentration. The results of detection and recovery experiments for Cr(III) in tea, soil and water were satisfactory, indicating that the method has better feasibility and application potential in the routine determination and speciation of Cr(III)/Cr(VI). The results of analysis of the certified reference material (INCT-TL-1 tea sample and CWW-TM-D waste water) are in good agreement with the certified value.

  17. Development and application of a method for Cr(III) determination in dairy products by HPLC-ICP-MS.

    Science.gov (United States)

    Hernandez, Fanny; Jitaru, Petru; Cormant, Florence; Noël, Laurent; Guérin, Thierry

    2018-02-01

    This study describes the development of an analytical approach for the determination of Cr(III) in dairy products by microwave assisted extraction, complexation in situ by ethylenediaminetetraacetate (EDTA) and high performance liquid chromatography hyphenated to inductively coupled plasma-mass spectrometry (HPLC-ICP-MS). The extraction step was optimised by using an experimental design. A limit of quantification of 38µgkg -1 dry weight (d.w.) was obtained whereas the bias (%) measured ranged from 10 to 18%. The repeatability and intermediate precision varied between 1.2-5.0% and 7.5-13.5%, respectively. The method was applied to the analysis of several dairy samples beforehand characterized in terms of Cr(VI) and total chromium (Cr total ). Cr(III) concentrations ranged from <13 to 255µgkg -1 d.w. The results showed a good agreement between Cr(III) and Cr total concentration levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Electric field effect of GaAs monolayer from first principles

    Directory of Open Access Journals (Sweden)

    Jiongyao Wu

    2017-03-01

    Full Text Available Using first-principle calculations, we investigate two-dimensional (2D honeycomb monolayer structures composed of group III-V binary elements. It is found that such compound like GaAs should have a buckled structure which is more stable than graphene-like flat structure. This results a polar system with out-of-plane dipoles arising from the non-planar structure. Here, we optimized GaAs monolayer structure, then calculated the electronic band structure and the change of buckling height under external electric field within density functional theory using generalized gradient approximation method. We found that the band gap would change proportionally with the electric field magnitude. When the spin-orbit coupling (SOC is considered, we revealed fine spin-splitting at different points in the reciprocal space. Furthermore, the valence and conduction bands spin-splitting energies due to SOC at the K point of buckled GaAs monolayers are found to be weakly dependent on the electric field strength. Finally electric field effects on the spin texture and second harmonic generation are discussed. The present work sheds light on the control of physical properties of GaAs monolayer by the applied electric field.

  19. Isothiocyanato complexes of Gd(III), Tb(III), Dy(III) and Ho(III) with 2-(2'-pyridyl)benzimidazole

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, A; Singh, V K

    1982-01-01

    Six-coordinated complexes of the type (Ln(PyBzH)/sub 2/NCS.H/sub 2/O) (NCS)/sub 2/.nH/sub 2/O/mC/sub 2/H/sub 5/OH (Ln = Gd(III), Tb(III), Dy(III) and Ho(III), n=1-2; m=1) have been prepared from Ln(NCS)/sub 6//sup 3 -/. The room temperature magnetic moment values confirm the terpositive state of the lanthanide ions. Infrared spectra suggest the N-coordination of thiocyanate group. Electronic spectral studies of Tb(III), Dy(III) and Ho(III) complexes have been made in terms of LSJ term energies. 13 refs.

  20. Characterization of the lanthanum(III) and europium(III) trichloroacetate complexes extracted with 18-crown-6

    International Nuclear Information System (INIS)

    Imura, H.; Saito, Y.; Ohashi, K.; Meguro, Y.; Yoshida, Z.; Choppin, G.R.

    1996-01-01

    Extraction of lanthanide(III) ions with 18-crown-6 (18C6) and trichloroacetate (tca) has been studied. The composition, hydration, and structure of the La(III) and Eu(III) complexes extracted into 1,2-dichloroethane were investigated by using several methods such as the liquid-liquid distribution technique, conductimetry, Karl Fisher titration, laser luminescence spectroscopy, and 1 H NMR. The La(III) complex was found to be a monohydrate, La(tca) 3 (18C6)(H 2 O), while that of Eu(III) was a mixture of a monohydrate and a dihydrate, i.e., Eu(tca) 3 (18C6)(H 2 O) and Eu(tca) 3 (18C6)(H 2 O) 2 . The origin of the selectivity by 18C6 which gives much higher extractability of La(III) than of Eu(III) is explained by considering the hydration and probable structure of their complexes. 12 refs., 5 figs., 4 tabs

  1. Gen-III/III+ reactors. Solving the future energy supply shortfall. The SWR-1000 option

    International Nuclear Information System (INIS)

    Stosic, Z.V.

    2006-01-01

    Deficiency of non-renewable energy sources, growing demand for electricity and primary energy, increase in population, raised concentration of greenhouse gases in the atmosphere and global warming are the facts which make nuclear energy currently the most realistic option to replace fossil fuels and satisfy global demand. The nuclear power industry has been developing and improving reactor technology for almost five decades and is now ready for the next generation of reactors which should solve the future energy supply shortfall. The advanced Gen-III/III+ (Generation III and/or III+) reactor designs incorporate passive or inherent safety features which require no active controls or operational intervention to manage accidents in the event of system malfunction. The passive safety equipment functions according to basic laws of physics such as gravity and natural convection and is automatically initiated. By combining these passive systems with proven active safety systems, the advanced reactors can be considered to be amongst the safest equipment ever made. Since the beginning of the 90's AREVA NP has been intensively engaged in the design of two advanced Gen-III+ reactors: (i) PWR (Pressurized Water Reactor) EPR (Evolutionary Power Reactor) and (ii) BWR (Boiling Water Reactor) SWR-1000. The SWR-1000 reactor design marks a new era in the successful tradition of BWR technology. It meets the highest safety standards, including control of a core melt accident. This is achieved by supplementing active safety systems with passive safety equipment of diverse design for accident detection and control and by simplifying systems needed for normal plant operation. A short construction period, flexible fuel cycle lengths and a high fuel discharge burn-up contribute towards meeting economic goals. The SWR-1000 completely fulfils international nuclear regulatory requirements. (author)

  2. Kinetic determination of As(III in solution

    Directory of Open Access Journals (Sweden)

    TODOR G. PECEV

    2003-10-01

    Full Text Available A new reaction is suggested and a new kinetic method is elaborated for the As(III traces determination in solution, on the basis of their catalyzing effect on komplexon III (EDTA oxidation by KMnO4 in a strong acid solution (H2SO4. Using a spectrophotometric technique, a sensitivity of 72 ng/cm3 As(III was achieved. The relative error of method varies from 5.5 to 13.9 % for As(III concentration range from 83 to 140 ng/cm3. Appropriate kinetic equations are formulated and the influence of some other ions, including the As(V, upon the reaction rate is tested.

  3. Synthesis, spectral characterization and in vitro antifungal activity of Lanthanum(III) and Praseodymium(III) complexes with Schiff bases derived from 5-substituted-4-amino-5-hydrazino-1,2,4-triazoles and isatin

    International Nuclear Information System (INIS)

    Singh, Shweta; Tripathi, Priti; Pandey, Om P.; Sengupta, Soumitra K.

    2013-01-01

    The new lanthanum(III) and praseodymium(III) complexes of the general formula (LnCl(L)(H 2 O) 2 ) (Ln = La III or Pr III ; H 2 L = Schiff bases derived from 3-substituted-4-amino-5-hydrazino-1,2,4-triazoles and isatin) have been prepared. The complexes have been characterized by elemental analyses, molecular weight by FAB-mass, thermogravimetry, electrical conductance, magnetic moment and spectral (electronic, infrared, far-infrared, 1 H NMR and 13 C NMR) data. The ligands and all prepared complexes were assayed for antifungal (Aspergillus niger and Helminthosporium oryzae) activities. The activities have been correlated with the structures of the complexes. (author)

  4. Electrosorption of As(III) in aqueous solutions with activated carbon as the electrode

    Science.gov (United States)

    Dai, Min; Xia, Ling; Song, Shaoxian; Peng, Changsheng; Rangel-Mendez, Jose Rene; Cruz-Gaona, Roel

    2018-03-01

    The electrosorption of As(III) in aqueous solutions by using activated carbon (AC) as the electrode was studied in this work. This study was performed through the measurements of adsorption and desorption, Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and X-ray photoelectron spectra (XPS). Three parameters, applied voltage, solution pH and initial As(III) concentration, on the electrosoprtion of As(III) were investigated. The experimental results have demonstrated that the electrosorption followed three steps: migration of As(III) to the anode, oxidation of As(III) to As(V) and accumulation of As(V) in the electric double layers of the anode. The electrodorption capacity increased with increasing applied voltage and initial As(III) concentration, whereas the effect of pH was complicated for the variation of arsenite species and the competition of OH-. The oxidation of As(III) increased with the increasing voltage and pH due to the increasing redox potential acted on As(III). The electrosorption served to reduce the toxicity of arsenic and was a promising technology for As(III) removal from water.

  5. Structural Characterization of Am(III)- and Pu(III)-DOTA Complexes.

    Science.gov (United States)

    Audras, Matthieu; Berthon, Laurence; Berthon, Claude; Guillaumont, Dominique; Dumas, Thomas; Illy, Marie-Claire; Martin, Nicolas; Zilbermann, Israel; Moiseev, Yulia; Ben-Eliyahu, Yeshayahu; Bettelheim, Armand; Cammelli, Sebastiano; Hennig, Christoph; Moisy, Philippe

    2017-10-16

    The complexation of 1,4,7,10-tetrazacyclodecane-1,4,7,10-tetraacetic acid (DOTA) ligand with two trivalent actinides (Am 3+ and Pu 3+ ) was investigated by UV-visible spectrophotometry, NMR spectroscopy, and extended X-ray absorption fine structure in conjunction with computational methods. The complexation process of these two cations is similar to what has been previously observed with lanthanides(III) of similar ionic radius. The complexation takes place in different steps and ends with the formation of a (1:1) complex [(An(III)DOTA)(H 2 O)] - , where the cation is bonded to the nitrogen atoms of the ring, the four carboxylate arms, and a water molecule to complete the coordination sphere. The formation of An(III)-DOTA complexes is faster than the Ln(III)-DOTA systems of equivalent ionic radius. Furthermore, it is found that An-N distances are slightly shorter than Ln-N distances. Theoretical calculations showed that the slightly higher affinity of DOTA toward Am over Nd is correlated with slightly enhanced ligand-to-metal charge donation arising from oxygen and nitrogen atoms.

  6. A modified Wheeler cap method for radiation efficiency measurement of balanced electrically small antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Pivnenko, Sergey; Breinbjerg, Olav

    2010-01-01

    , but not for balanced antennas like loops or dipoles. In this paper, a modified Wheeler cap method is proposed for the radiation efficiency measurement of balanced electrically small antennas and a three-port network model of the Wheeler cap measurement is introduced. The advantage of the modified method...... is that it is wideband, thus does not require any balun, and both the antenna input impedance and radiation efficiency can be obtained. An electrically small loop antenna and a wideband dipole were simulated and measured according to the proposed method and the results of measurements and simulations are presented...

  7. Studying the influence of pore water electrical conductivity on the formation factor, as estimated based on electrical methods

    Energy Technology Data Exchange (ETDEWEB)

    Loefgren, Martin (Kemakta Konsult AB, Stockholm (Sweden)); Vecernik, Petr; Havlova, Vaclava (Waste Disposal Dept., Nuclear Research Institute Rez plc. (Czech Republic))

    2009-11-15

    In this report the geometric formation factor, as obtained in tracer tests, is compared with the apparent formation factor, as obtained by electrical methods. This should provide information on the data uncertainty associated with the electrical methods utilised in situ within the SKB site investigation programme. Generally, if directly estimating the formation factor from the apparent formation factor, there is a risk of substantial overestimations. This is especially the case at shallow depth at the Forsmark and Oskarshamn sites, where the groundwater is of low salinity. This study is performed on nine drill core samples from the Forsmark and Oskarshamn sites. The formation factor and apparent formation factor of these samples have previously been determined by the through diffusion method, using HTO as the tracer, and by the electrical resistivity method, as part of the site investigation programme. The study is divided in two parts where part 2 was performed successfully, while part 1 suffered from problems. In part 2, eight rock samples were saturated by either a 0.05 or 0.1 M NaCl electrolyte. These electrolytes should represent the groundwater at repository depth. The formation factor of these samples was obtained by the through-electromigration (TEM) method, using iodide as the tracer. In addition, the apparent formation factors were obtained by electrical resistivity methods using direct current and alternating current at 10, 100, and 2,000 Hz. The measurements were performed in duplicates or triplicates, and generally a good reproducibility was achieved. As expected, the apparent formation factors were a few times larger than the TEM formation factor for the same sample. The ratio of the apparent formation factors and TEM formation factors range between about 2 and 12, where larger ratios were found for rock samples of low formation factors. The results were compared with modelled apparent formation factors, where input data were a range of formation

  8. Studying the influence of pore water electrical conductivity on the formation factor, as estimated based on electrical methods

    International Nuclear Information System (INIS)

    Loefgren, Martin; Vecernik, Petr; Havlova, Vaclava

    2009-11-01

    In this report the geometric formation factor, as obtained in tracer tests, is compared with the apparent formation factor, as obtained by electrical methods. This should provide information on the data uncertainty associated with the electrical methods utilised in situ within the SKB site investigation programme. Generally, if directly estimating the formation factor from the apparent formation factor, there is a risk of substantial overestimations. This is especially the case at shallow depth at the Forsmark and Oskarshamn sites, where the groundwater is of low salinity. This study is performed on nine drill core samples from the Forsmark and Oskarshamn sites. The formation factor and apparent formation factor of these samples have previously been determined by the through diffusion method, using HTO as the tracer, and by the electrical resistivity method, as part of the site investigation programme. The study is divided in two parts where part 2 was performed successfully, while part 1 suffered from problems. In part 2, eight rock samples were saturated by either a 0.05 or 0.1 M NaCl electrolyte. These electrolytes should represent the groundwater at repository depth. The formation factor of these samples was obtained by the through-electromigration (TEM) method, using iodide as the tracer. In addition, the apparent formation factors were obtained by electrical resistivity methods using direct current and alternating current at 10, 100, and 2,000 Hz. The measurements were performed in duplicates or triplicates, and generally a good reproducibility was achieved. As expected, the apparent formation factors were a few times larger than the TEM formation factor for the same sample. The ratio of the apparent formation factors and TEM formation factors range between about 2 and 12, where larger ratios were found for rock samples of low formation factors. The results were compared with modelled apparent formation factors, where input data were a range of formation

  9. [A physiological investigation of chronic electrical stimulation with scala tympani electrodes in kittens].

    Science.gov (United States)

    Ni, D

    1992-12-01

    A physiological investigation of cochlear electrical stimulation was undertaken in six two-month-old kittens. The scala tympani electrodes were implanted and electrically stimulated using biphasic balanced electrical pulses for periods of 1000-1500h in four ears. Four ears received implants for same period but without electrical stimulation. The other two ears served as normal control. The results indicated: 1) Chronic electrical stimulation of the cochlea within electrochemically safe limits did not influence the hearing of kittens and the normal delivery of impulses evoked by acoustic and electrical signals on the auditory brainstem pathway. 2) The wave shapes of EABRs were similar to those of ABRs. The amplitudes of EABRs showed a significant increase following chronic electrical stimulation, resulting in a leftward shift in the input/output function. The absolute latencies and interwave latencies of waves II-III, III-IV and II-IV were significantly shorter than those of ABRs. These results imply that there was no adverse effect of chronic electrical stimulation on the maturing auditory systems of kittens using these electrical parameters and the mechanism of electrical hearing should be further studied.

  10. Adsorption characteristics of methane on Maxsorb III by gravimetric method

    KAUST Repository

    Thu, Kyaw

    2014-11-01

    Adsorption characteristics of CH4 on the carbonaceous porous material is evaluated for possible application in adsorbed natural gas (ANG) system. Adsorption uptakes at assorted temperatures (25-80 °C) and pressures ranging from ambient to relatively high pressure i.e., 8.0 MPa are experimentally investigated. Surface characteristics such as pore surface area, micropore volume and pore size distribution of the adsorbent (Maxsorb III) are first evaluated using Classical Volumetric Method i.e., the manometric method with N2 gas adsorption at 77 K. The sorption measurements for methane, CH4 gas are carried out by thermogravimetric (TGA) method using magnetic suspension balance coupled with the automatic dosing system. The buoyancy measurements were first conducted using Helium gas as adsorbate. Buoyancy correction is applied to all sets of measured data and the specific uptake capacities (g/g of adsorbent) at various temperatures and pressures were calculated. The isotherm data were then fitted using Langmuir and Tòth isotherm models. It is observed that the data can be satisfactorily fitted using Tòth model with excellent fitting accuracy around 2.2% within the experimental range. The outcome of the present study especially the adsorption data at high pressures is applicable to accurate design and modeling of Adsorbed Natural Gas (ANG) systems. © 2014 Elsevier Ltd. All rights reserved.

  11. Preparation and studies of Co(II) and Co(III)-substituted barium ferrite prepared by sol-gel method

    Energy Technology Data Exchange (ETDEWEB)

    Teh, Geok Bee [Department of Bioscience and Chemistry, Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, 53300 Kuala Lumpur (Malaysia)]. E-mail: tehgb@mail.utar.edu.my; Nagalingam, Saravanan [Department of Bioscience and Chemistry, Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, 53300 Kuala Lumpur (Malaysia); Jefferson, David A. [Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW (United Kingdom)

    2007-01-15

    The sol-gel preparative method was employed to synthesise Co(II) and Co(III)-substituted barium ferrite. This method was attempted to achieve higher homogeneity of the final product. Samples of substituted ferrites were characterised by various experimental techniques including high resolution transmission electron microscopy, X-ray diffraction analysis, magnetometry and thermal gravimetric analysis. The microstructural changes induced by such substitution are also discussed.

  12. Preparation and studies of Co(II) and Co(III)-substituted barium ferrite prepared by sol-gel method

    International Nuclear Information System (INIS)

    Teh, Geok Bee; Nagalingam, Saravanan; Jefferson, David A.

    2007-01-01

    The sol-gel preparative method was employed to synthesise Co(II) and Co(III)-substituted barium ferrite. This method was attempted to achieve higher homogeneity of the final product. Samples of substituted ferrites were characterised by various experimental techniques including high resolution transmission electron microscopy, X-ray diffraction analysis, magnetometry and thermal gravimetric analysis. The microstructural changes induced by such substitution are also discussed

  13. Control Analysis of Hazards Potential in Crude Distiller Unit III PT. Pertamina (Persero) Refinery Unit III Plaju Tahun 2011

    OpenAIRE

    Matariani, Ade; Hasyim, Hamzah; Faisya, Achmad Fickry

    2012-01-01

    Background: Activities in CDU III are very risk to any hazards potential; because of that hazards potential is much needed in controlling the hazards potential to decrease the accidents and occupational diseases. The aim of this study was to analyze the controlling of hazards potential in CDU III PT. Pertamina (Persero) RU III Plaju in 2011. Method: This study was a qualitative study. The methods of data collection were using in-depth interview and observation. The total of informants in this...

  14. Complexation of trivalent actinides and lanthanides with hydrophilic N-donor ligands for Am(III)/Cm(III) and An(III)/Ln(III) separation; Komplexierung von trivalenten Actiniden und Lanthaniden mit hydrophilen N-Donorliganden zur Am(III)/Cm(III)- bzw. An(III)/Ln(III)-Trennung

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Christoph

    2017-07-24

    The implementation of actinide recycling processes is considered in several countries, aiming at the reduction of long-term radiotoxicity and heat load of used nuclear fuel. This requires the separation of the actinides from the fission and corrosion products. The separation of the trivalent actinides (An(III)) Am(III) and Cm(III), however, is complicated by the presence of the chemically similar fission lanthanides (Ln(III)). Hydrophilic N-donor ligands are employed as An(III) or Am(III) selective complexing agents in solvent extraction to strip An(III) or Am(III) from an organic phase loaded with An(III) and Ln(III). Though they exhibit excellent selectivity, the complexation chemistry of these ligands and the complexes formed during solvent extraction are not sufficiently characterized. In the present thesis the complexation of An(III) and Ln(III) with hydrophilic N-donor ligands is studied by time resolved laser fluorescence spectroscopy (TRLFS), UV/Vis, vibronic sideband spectroscopy and solvent extraction. TRLFS studies on the complexation of Cm(III) and Eu(III) with the Am(III) selective complexing agent SO{sub 3}-Ph-BTBP (tetrasodium 3,3{sup '},3'',3{sup '''}-([2,2{sup '}-bipyridine]-6,6{sup '}-diylbis(1,2,4-triazine-3,5,6-triyl)) tetrabenzenesulfonate) revealed the formation of [M(SO{sub 3}-Ph-BTBP){sub n}]{sup (4n-3)-} complexes (M = Cm(III), Eu(III); n = 1, 2). The conditional stability constants were determined in different media yielding two orders of magnitude larger β{sub 2}-values for the Cm(III) complexes, independently from the applied medium. A strong impact of ionic strength on the stability and stoichiometry of the formed complexes was identified, resulting from the stabilization of the pentaanionic [M(SO{sub 3}-Ph-BTBP){sub 2}]{sup 5-} complex with increasing ionic strength. Thermodynamic studies of Cm(III)-SO{sub 3}-Ph-BTBP complexation showed that the proton concentration of the applied medium impacts

  15. Wide bandgap collector III-V double heterojunction bipolar transistors

    International Nuclear Information System (INIS)

    Flitcroft, R.M.

    2000-10-01

    This thesis is devoted to the study and development of Heterojunction Bipolar Transistors (HBTs) designed for high voltage operation. The work concentrates on the use of wide bandgap III-V semiconductor materials as the collector material and their associated properties influencing breakdown, such as impact ionisation coefficients. The work deals with issues related to incorporating a wide bandgap collector into double heterojunction structures such as conduction band discontinuities at the base-collector junction and results are presented which detail, a number of methods designed to eliminate the effects of such discontinuities. In particular the use of AlGaAs as the base material has been successful in eliminating the conduction band spike at this interface. A method of electrically injecting electrons into the collector has been employed to investigate impact ionisation in GaAs, GaInP and AlInP which has used the intrinsic gain of the devices to extract impact ionisation coefficients over a range of electric fields beyond the scope of conventional optical injection techniques. This data has enabled the study of ''dead space'' effects in HBT collectors and have been used to develop an analytical model of impact ionisation which has been incorporated into an existing Ebers-Moll HBT simulator. This simulator has been shown to accurately reproduce current-voltage characteristics in both the devices used in this work and for external clients. (author)

  16. Load Flow and Short Circuit Analysis of the Class III Power System of HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H. K.; Jung, H. S

    2005-12-15

    The planning, design, and operation of electric power system require engineering studies to assist in the evaluation of the system performance, reliability, safety and economics. The Class III power of HANARO supplies power for not only HANARO but also RIPF and IMEF. The starting current of most ac motors is five to ten times normal full load current. The loads of the Class III power are connected in consecutive orders at an interval for 10 seconds to avoid excessive voltage drop. This technical report deals with the load flow study and motor starting study for the Class III power of HANARO using ETAP(Electrical Transient Analyzer Program) to verify the capacity of the diesel generator. Short-circuit studies are done to determine the magnitude of the prospective currents flowing throughout the power system at various time intervals after a fault occurs. Short-circuit studies can be performed at the planning stage in order to help finalize the system layout, determine voltage levels, and size cables, transformers, and conductors. From this study, we verify the short circuit current capacity of air circuit breaker(ACB) and automatic transfer switch(ATS) of the Class III power.

  17. The implementation and application of the WASP-III at CNEN/Brazil

    International Nuclear Information System (INIS)

    Sakamoto, L.H.; Lima, J.O.V.; Silva, R.C.O. da.

    1983-09-01

    The main dificulties faced in the implementation of the WASP-III on the Honeywell Bull DPS 6/64 computer at CNEN, are discribed. After the implementation, tests making use of input data provided by International Atomic Energy Agency - IAEA were performed and comparative results from accomplishment peiods of time are presented with the basic characteristics of the computer employed and the modifications carried out to adapt the programm. The WASP-III was applied to middle-sized electric system based upon the Brazilian North/Northeast System. (Author) [pt

  18. Methods for detecting and locating leaks in containment facilities using electrical potential data and electrical resistance tomographic imaging techniques

    Science.gov (United States)

    Daily, William D.; Laine, Daren L.; Laine, Edwin F.

    1997-01-01

    Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid though the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution.

  19. Silver carbonate and stability in colloidal silver: A by-product of the electric spark discharge method

    International Nuclear Information System (INIS)

    Tseng, Kuo-Hsiung; Liao, Chih-Yu; Tien, Der-Chi

    2010-01-01

    Many methods of producing colloidal silver (CS) include the introduction of surfactants to improve the suspensivity of the silver particles. The electric spark discharge method (ESDM) which involves pulses of direct current being passed through a silver electrode submerged in deionized water has been shown to successfully produce colloidal silver in a stable suspension without the use of chemical additives. A by-product of the electric spark discharge method, a silver ion compound (AgX), is shown to be the cause of the high suspensivity of the silver nanoparticles (AgNPs). The silver ion compound has been identified as Ag 2 CO 3 using X-ray diffraction, and it has been determined that the Ag 2 CO 3 is formed during the electric spark discharge process through a reaction with atmospheric CO 2 . It has been shown that an Ag 2 CO 3 concentration of 10 ppm or more is sufficient to generate a stable suspension of silver particles. Because of the occurrence of Ag 2 CO 3 , the electric spark discharge method can produce stable colloidal silver.

  20. Research on Inferring ELECTRE-III’s Parameters with Fuzzy information and A Case on Naval Gun Weapon System Integration

    Directory of Open Access Journals (Sweden)

    Sun Shi Yan

    2016-01-01

    Full Text Available Multiple attributes decision making (MADM method is an important measure for system integration. Robustness analysis on MADM is a hotspot in these years which wins academe’s great attention, and is supposed to be an effective way when countering imperfect information. Setting parameters in ELECTRE-III’s is a vital and difficult step. In this paper, a method of inferring ELECTRE-III’s parameters with fuzzy information based on robustness analysis is presented. First, ELECTRE-III is transformed into a continuous smooth function of each parameter vector. Then, robustness analysis structure and a parameters inferring algorithm are provided by maximizing robustness margin based on mathematics programming. Moreover, how to resolve the programming problem is also discussed. At last, a illustrative example of Naval Gun Weapon System Integration is put forward.

  1. Method for Measuring Small Nonlinearities of Electric Characteristics

    DEFF Research Database (Denmark)

    Guldbrandsen, Tom; Meyer, Niels I; Schjær-Jacobsen, Jørgen

    1965-01-01

    A method is described for measuring very small deviations from linearity in electric characteristics. The measurement is based on the harmonics generated by the nonlinear element when subjected to a sine wave signal. A special bridge circuit is used to balance out the undesired harmonics...... of the signal generator together with the first harmonic frequency. The set-up measures the small-signal value and the first and second derivative with respect to voltage. The detailed circuits are given for measuring nonlinearities in Ohmic and capacitive components. In the Ohmic case, a sensitivity...

  2. Complexes of 4-chlorophenoxyacetates of Nd(III), Gd(III) and Ho(III)

    International Nuclear Information System (INIS)

    Ferenc, W.; Bernat, M; Gluchowska, H.W.; Sarzynski, J.

    2010-01-01

    The complexes of 4-chlorophenoxyacetates of Nd(III), Gd(III) and Ho(III) have been synthesized as polycrystalline hydrated solids, and characterized by elemental analysis, spectroscopy, magnetic studies and also by X-ray diffraction and thermogravimetric measurements. The analysed complexes have the following colours: violet for Nd(III), white for Gd(III) and cream for Ho(III) compounds. The carboxylate groups bind as bidentate chelating (Ho) or bridging ligands (Nd, Gd). On heating to 1173K in air the complexes decompose in several steps. At first, they dehydrate in one step to form anhydrous salts, that next decompose to the oxides of respective metals. The gaseous products of their thermal decomposition in nitrogen were also determined and the magnetic susceptibilities were measured over the temperature range of 76-303K and the magnetic moments were calculated. The results show that 4-chlorophenoxyacetates of Nd(III), Gd(III) and Ho(III) are high-spin complexes with weak ligand fields. The solubility value in water at 293K for analysed 4-chlorophenoxyacetates is in the order of 10 -4 mol/dm 3 . (author)

  3. Method of estimating horizontal vectors of ionospheric electric field deduced from HF Doppler data

    International Nuclear Information System (INIS)

    Tsutsui, M.; Ogawa, T.; Kamide, Y.; Kroehl, H.W.; Hausman, B.A.

    1988-01-01

    An HF Doppler method for estimating the time variations of the horizontal electric field in the ionosphere is presented which takes into account, for long-lasting variations in the electric field, the effect of electron decay due to attachment and/or recombination processes. The method is applied to an isolated substorm event, using equivalent ionospheric current systems deduced from worldwide magnetometer data in the estimations. The present results are found to agree with data deduced from current systems and high latitude electrojet activity. 18 references

  4. Electricity Information 2013 with 2012 data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-01

    Electricity Information provides a comprehensive review of historical and current market trends in the OECD electricity sector, including 2012 preliminary data. An Introduction, notes, definitions and auxiliary information are provided in Part I. Part II of the publication provides an overview of the world electricity developments in 2011, covering world electricity and heat production, input fuel mix, supply and consumption, and electricity imports and exports. A greater focus is given to the 34 OECD countries with more detailed information covering production, installed capacity, input energy mix to electricity and heat production, consumption, electricity trades, input fuel prices and end-user electricity prices. Part III of the publication provides a corresponding statistical overview of developments in the world and OECD electricity and heat market for 2011, as well as monthly OECD production and trade electricity data for 2012. Part IV provides, in tabular form, detailed and comprehensive statistical coverage of the power and heat industry developments for each of the OECD member countries and for OECD and IEA regional aggregates. It provides comprehensive statistical details on overall energy consumption, economic indicators, electricity and heat production by energy form and plant type, electricity imports and exports, sectoral energy and electricity consumption as well as prices for electricity and electricity input fuels for each country and regional aggregate.

  5. Studies on mixed ligand complexes of lanthanide (III) ions

    International Nuclear Information System (INIS)

    Rajendran, G.; Usha Devi, K.G.

    2002-01-01

    As part of our research programme, we have prepared and characterized a few nitrato, thiocyanato and perchlorato complexes of lanthanide(III) ions with ligands, viz., a Schiff base derived from p-anisidine and vanillin and diphenyl sulphoxide. The complexes were characterized by the measurement of electrical conductances and magnetic susceptibilities, molecular mass and metal percentage and spectral analysis. The thermal decompositions were studied by TG and DTG techniques. The thiocyanato complexes were prepared by substitution method from nitrato complexes. p-Anisidine-vanillin (HDDA) and diphenyl sulphoxide (DPSO) are coordinated to the metal ion in unidentate fashion. All the anions were involved in coordination in these complexes. Thus they were found to have non- electrolytic behaviour with composition [Ln(HDDA) 2 (DPSO)X 3 ] where X = NO 3 ) or SCN perchlorato complexes were prepared from metal perchlorate as done in the case of nitrato complexes. They were found to have electrical conductance which corresponds to 1 : 1 electrolyte. Hence one of the perchlorate ions is outside the coordination sphere. The composition of this complex is found to be [Ln(HDDA) 3 (DPSO)(ClO 4 ) 2 ]ClO 4 . (author)

  6. Design and Construction of Equipment for Applying the Geophysical Prospecting Method Electric Tomography

    Directory of Open Access Journals (Sweden)

    Fabio Héctor Giraldo Sánchez

    2013-06-01

    Full Text Available Outlines the procedure for the design and construction of electric equipment for geophysical prospecting through electrical tomography method. The team is of average power, ensuring exploration depths quite suitable for applications and commercial and geotechnical studies. The device is essentially a DC voltage source of 500 volts that is able to provide a maximum current of 1 amp. It also contains a small charge current source of electrical currents counteract naturally found in the subsoil and are manifested as a difference in the surface potential. A general explanation of the geophysical method in question, helps to understand the basic principles of operation of the equipment and functions to be fulfilled. After building the team, we conducted a field data acquisition, in area near the town of Gachancipa Cundinamarca. The data from this equipment are processed with specialized software. The images obtained with the software presents the distributions of subsurface resistivity can be associated with the possible structures and geology of the study area.

  7. Phase II Results of RTOG 0537: A Phase II/III Study Comparing Acupuncture-like Transcutaneous Electrical Nerve Stimulation Versus Pilocarpine in Treating Early Radiation-Induced Xerostomia

    Science.gov (United States)

    Wong, Raimond K. W.; James, Jennifer L.; Sagar, Stephen; Wyatt, Gwen; Nguyen-Tân, Phuc Felix; Singh, Anurag K.; Lukaszczyk, Barbara; Cardinale, Francis; Yeh, Alexander M.; Berk, Lawrence

    2011-01-01

    Purpose This phase II component of a multi-institutional phase II/III randomized trial assessed the feasibility and preliminary efficacy of acupuncture-like transcutaneous electrical nerve stimulation (ALTENS) in reducing radiation-induced xerostomia. Methods Head and neck cancer patients who were 3–24 months from completing radiotherapy ± chemotherapy (RT±C) and experiencing xerostomia symptoms with basal whole saliva production ≥0.1 ml/min and without recurrence were eligible. Patients received twice weekly ALTENS sessions (24 over 12 weeks) using a Codetron™ unit. The primary objective assessed the feasibility of ALTENS treatment. A patient was considered compliant if 19/24 ALTENS were delivered, with a targeted 85% compliance rate. Secondary objectives measured treatment-related toxicities and ALTENS effect on overall radiation-induced xerostomia burden using the University of Michigan Xerostomia-Related Quality of Life Scale (XeQOLS). Results Of 48 accrued patients, 47 were evaluable. Median age was 60 years; 84% were male, 70% completed RT±C for > 12 months and 21% had received prior pilocarpine. All ALTENS sessions were completed in 34 patients, but 9 and 1 completed 20–23 and 19 sessions respectively, representing a 94% total compliance rate. 6-month XeQOLS scores were available for 35 patients; 30 (86%) achieved a positive treatment response with a mean reduction of 35.9% (SD 36.1). Five patients developed grade 1–2 gastrointestinal toxicity and one had grade 1 pain event. Conclusions ALTENS treatment for radiation-induced xerostomia can be uniformly delivered in a cooperative multicenter setting and has possible beneficial treatment response. Given these results, the phase III component of this study was initiated. PMID:22252927

  8. Antithrombin III for critically ill patients

    DEFF Research Database (Denmark)

    Allingstrup, Mikkel; Wetterslev, Jørn; Ravn, Frederikke B

    2016-01-01

    PURPOSE: Antithrombin III (AT III) is an anticoagulant with anti-inflammatory properties. We assessed the benefits and harms of AT III in critically ill patients. METHODS: We searched from inception to 27 August 2015 in CENTRAL, MEDLINE, EMBASE, CAB, BIOSIS and CINAHL. We included randomized...... participants). However, for all other outcome measures and analyses, the results did not reach statistical significance. CONCLUSIONS: There is insufficient evidence to support AT III substitution in any category of critically ill participants including those with sepsis and DIC. AT III did not show an impact...

  9. Determination of Cu(III) and Cu(II)+Cu(III) in superconducting copper ceramics

    International Nuclear Information System (INIS)

    Nedelcheva, T.; Kostadinova, L.; Stoyanova-Ivanova, A.; Ivanova, I.

    1992-01-01

    Copper(III) and total copper in superconducting Y-Ba-Cu oxide and related compounds can be determinated by two successive iodimetric titrations after the sample has been dissolved under Ar in HCl/KI medium. First, the iodine equivalent to copper(III) is titrated with Na 2 S 2 O 3 solution at pH 4.8, copper(II) being masked with EDTA. The total copper is then determined in the same solution by demasking with acid and iodide, followed by iodimetric titration. The method is both accurate and reproducible. The relative standard deviations for 1.074% copper(III) and 23.37% total copper are 0.8% and 0.3%, respectively. (orig.)

  10. Development of the electrical discharge method for water disinfection

    International Nuclear Information System (INIS)

    Vojtenko, L.M.; Kononov, O.V.; Starchik, P.D.; Samojlenko, L.S.; Stavs'ka, S.S.

    1995-01-01

    Studies of processes of bacterially polluted water disinfection by the method of pulse electrical discharge in water are presented. The studies was performed to improve the disinfection technology. Main attention was concentrated to clear up effect of discharge instability on the disinfection. An influence of the shape and sizes of electrodes on repeatability of discharges was also investigated. It was found that salts solved in water greatly influence ultraviolet radiation absorption coefficients

  11. Permanganate/bisulfite (PM/BS) conditioning-horizontal electro-dewatering (HED) of activated sludge: Effect of reactive Mn(III) species.

    Science.gov (United States)

    Guo, Xinxin; Wang, Yili; Wang, Dongsheng

    2017-11-01

    A novel activated sludge (AS) conditioning method through permanganate/bisulfate (PM/BS) process was proposed. The method involved a new conditioner of reactive Mn(III) intermediate. Moreover, a Mn(III) conditioning-horizontal electro-dewatering (Mn(III) C-HED) process was established to improve AS dewatering performance. Underlying mechanisms were unraveled by investigating changes in physicochemical characteristics, scanning electron microscope (SEM) morphology, and transformation of water and organic matters. The optimum dewatering conditions for Mn(III) C-HED process with the final water content of 86.94% were determined as the combination of KMnO 4 0.01 mol/L AS and NaHSO 3 0.05 mol/L AS at 20 V for 120 min. Results showed that Mn(III) C-HED process effectively reduced free water and bound water with the corresponding removal ratios of 51.68% and 87.62% at the anode-side as well as 36.55% and 85.08% at the cathode-side, respectively. During the PM/BS process, the produced Mn(III), Mn 2+ , and MnO 2 exerted chemical and physical effects on AS conditioning and dewatering. Mn(III) disintegrated extracellular polymeric substances (EPS) fractions and cells in AS, as well as induced partial bound water release. Additionally, flocculation effect induced by Mn 2+ and MnO 2 skeleton building also benefited AS dewatering. AS cells were further disrupted under the effect of a horizontal electric field. Accordingly, EPS within the AS matrix was solubilized, tightly bound (TB)-EPS or loosely bound (LB)-EPS was converted to their corresponding outer EPS fractions, and AS dewaterability improved. Additionally, changes in pH and temperature at HED stage damaged the AS cells and changed the floc properties, thereby leading to easy separation of liquid and AS particles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Electric gun: a new method for generating shock pressures in excess of 1 TPa

    International Nuclear Information System (INIS)

    Steinberg, D.; Chau, H.; Dittbenner, G.; Weingart, R.

    1978-01-01

    By combining the electrically-driven, flying-plate, high-explosive initiator with well-known gas-gun technology, a novel method of generating and measuring shock pressures greater than 1 TPa has been developed. Called the electric gun, this system is competitive with laser or nuclear-driven, shock-wave, equation-of-state experiments in the 1 to 5 TPa range. Compared to those other methods, it has the advantage of simplicity, high precision, and low cost. In addition, its small size and low total energy allow it to be easily contained for experiments with toxic materials

  13. Extraction behaviour of Am(III) and Eu(III) from nitric acid medium in TEHDGA-HDEHP impregnated resins

    Energy Technology Data Exchange (ETDEWEB)

    Saipriya, G.; Kumar, T. [Bhabha Atomic Research Centre Facilities, Kalpakkam (India). Kalpakkam Reprocessing Plant; Kumaresan, R.; Nayak, P.K.; Venkatesan, K.A.; Antony, M.P. [Indira Gandhi Center for Atomic Research, Kalpakkam (India). Fuel Chemistry Div.

    2016-07-01

    The extraction behaviour of Am(III) and Eu(III) from nitric acid medium was studied in the solvent impregnated resins containing extractants such as tetra-bis(2-ethylhexyl)diglycolamide (TEHDGA) or bis-(2-ethylhexyl)phosphoric acid (HDEHP) or mixture of TEHDGA+HDEHP. The rate of extraction of Am(III) and Eu(III) from 1 M nitric acid and the effect of various parameters, such as the concentration of nitric acid in aqueous phase and concentration of TEHDGA and HDEHP in resin phase, on the distribution coefficient of Am(III) and Eu(III) was studied. The distribution coefficient of Am(III) and Eu(III) in HDEHP-impregnated resin decreased and that in TEHDGA-impregnated resin increased, with increase in the concentration of nitric acid. However, in (TEHDGA+HDEHP) - impregnated resin, synergic extraction was observed at lower nitric acid concentration and antagonism at higher nitric acid concentration. The mechanism of Am(III) and Eu(III) extraction in the combined resin was investigated by slope analysis method. The extraction of various metal ions present in the fast reactor simulated high-level liquid waste was studied. The separation factor of Am(III) over Eu(III) was studied using citrate-buffered diethylenetriaminepentaacetic acid (DTPA) solution.

  14. NMR and TRLFS studies of Ln(iii) and An(iii) C5-BPP complexes.

    Science.gov (United States)

    Adam, Christian; Beele, Björn B; Geist, Andreas; Müllich, Udo; Kaden, Peter; Panak, Petra J

    2015-02-01

    C5-BPP is a highly efficient N-donor ligand for the separation of trivalent actinides, An(iii), from trivalent lanthanides, Ln(iii). The molecular origin of the selectivity of C5-BPP and many other N-donor ligands of the BTP-type is still not entirely understood. We present here the first NMR studies on C5-BPP Ln(iii) and An(iii) complexes. C5-BPP is synthesized with 10% 15 N labeling and characterized by NMR and LIFDI-MS methods. 15 N NMR spectroscopy gives a detailed insight into the bonding of C5-BPP with lanthanides and Am(iii) as a representative for trivalent actinide cations, revealing significant differences in 15 N chemical shift for coordinating nitrogen atoms compared to Ln(iii) complexes. The temperature dependence of NMR chemical shifts observed for the Am(iii) complex indicates a weak paramagnetism. This as well as the observed large chemical shift for coordinating nitrogen atoms show that metal-ligand bonding in Am(C5-BPP) 3 has a larger share of covalence than in lanthanide complexes, confirming earlier studies. The Am(C5-BPP) 3 NMR sample is furthermore spiked with Cm(iii) and characterized by time-resolved laser fluorescence spectroscopy (TRLFS), yielding important information on the speciation of trace amounts of minor complex species.

  15. Method of forming an electrically conductive cellulose composite

    Science.gov (United States)

    Evans, Barbara R [Oak Ridge, TN; O'Neill, Hugh M [Knoxville, TN; Woodward, Jonathan [Ashtead, GB

    2011-11-22

    An electrically conductive cellulose composite includes a cellulose matrix and an electrically conductive carbonaceous material incorporated into the cellulose matrix. The electrical conductivity of the cellulose composite is at least 10 .mu.S/cm at 25.degree. C. The composite can be made by incorporating the electrically conductive carbonaceous material into a culture medium with a cellulose-producing organism, such as Gluconoacetobacter hansenii. The composites can be used to form electrodes, such as for use in membrane electrode assemblies for fuel cells.

  16. Formation constants of Sm(III), Dy(III), Gd(III), Pr(III) and Nd(III) complexes of tridentate schiff base, 2-[(1H-benzimidazol-2-yl-methylene) amino] phenol

    International Nuclear Information System (INIS)

    Omprakash, K.L.; Chandra Pal, A.V.; Reddy, M.L.N.

    1982-01-01

    A new tridentate schiff base, 2- (1H-benzimidazol-2-yl-methylene)amino phenol derived from benzimididazole-2-carbo-xaldehyde and 2-aminophenol has been synthesised and characterised by spectral and analytical data. Proton-ligand formation constants of the schiff base and metal-ligand formation constants of its complexes with Sm(III), Dy(III), Gd(III), Nd(III) and Pr(III) have been determined potentiometrically in 50% (v/v) aqueous dioxane at an ionic strength of 0.1M (NaClO 4 ) and at 25deg C using the Irving-Rossotti titration technique. The order of stability constants (logβ 2 ) is found to be Sm(III)>Dy(III)>Gd(III)>Pr(III)>Nd(III). (author)

  17. Formation constants of Sm(III), Dy(III), Gd(III), Pr(III) and Nd(III) complexes of tridentate schiff base, 2-((1H-benzimidazol-2-yl-methylene) amino) phenol

    Energy Technology Data Exchange (ETDEWEB)

    Omprakash, K L; Chandra Pal, A V; Reddy, M L.N. [Osmania Univ., Hyderabad (India). Dept. of Chemistry

    1982-03-01

    A new tridentate schiff base, 2- (1H-benzimidazol-2-yl-methylene)amino phenol derived from benzimididazole-2-carbo-xaldehyde and 2-aminophenol has been synthesised and characterised by spectral and analytical data. Proton-ligand formation constants of the schiff base and metal-ligand formation constants of its complexes with Sm(III), Dy(III), Gd(III), Nd(III) and Pr(III) have been determined potentiometrically in 50% (v/v) aqueous dioxane at an ionic strength of 0.1M (NaClO/sub 4/) and at 25deg C using the Irving-Rossotti titration technique. The order of stability constants (log..beta../sub 2/) is found to be Sm(III)>Dy(III)>Gd(III)>Pr(III)>Nd(III).

  18. Multigrid methods III

    CERN Document Server

    Trottenberg, U; Third European Conference on Multigrid Methods

    1991-01-01

    These proceedings contain a selection of papers presented at the Third European Conference on Multigrid Methods which was held in Bonn on October 1-4, 1990. Following conferences in 1981 and 1985, a platform for the presentation of new Multigrid results was provided for a third time. Multigrid methods no longer have problems being accepted by numerical analysts and users of numerical methods; on the contrary, they have been further developed in such a successful way that they have penetrated a variety of new fields of application. The high number of 154 participants from 18 countries and 76 presented papers show the need to continue the series of the European Multigrid Conferences. The papers of this volume give a survey on the current Multigrid situation; in particular, they correspond to those fields where new developments can be observed. For example, se­ veral papers study the appropriate treatment of time dependent problems. Improvements can also be noticed in the Multigrid approach for semiconductor eq...

  19. Calorimetric Measurement for Internal Conversion Efficiency of Photovoltaic Cells/Modules Based on Electrical Substitution Method

    Science.gov (United States)

    Saito, Terubumi; Tatsuta, Muneaki; Abe, Yamato; Takesawa, Minato

    2018-02-01

    We have succeeded in the direct measurement for solar cell/module internal conversion efficiency based on a calorimetric method or electrical substitution method by which the absorbed radiant power is determined by replacing the heat absorbed in the cell/module with the electrical power. The technique is advantageous in that the reflectance and transmittance measurements, which are required in the conventional methods, are not necessary. Also, the internal quantum efficiency can be derived from conversion efficiencies by using the average photon energy. Agreements of the measured data with the values estimated from the nominal values support the validity of this technique.

  20. Testing the equation of state and electrical conductivity of copper by the electrical wire explosion in air: Experiment and magnetohydrodynamic simulation

    International Nuclear Information System (INIS)

    Barysevich, A. E.; Cherkas, S. L.

    2011-01-01

    We perform experiments on testing the equations of state and electrical conductivity of copper in three different regimes of copper wire electrical explosion, when the inserted energy (i) is slightly exceeded, (ii) is approximately equal, and (iii) is substantially exceeded the energy needed for the wire complete evaporation. Magnetohydrodynamic simulation is performed. The results predicted by the two different equations of state are compared with the experiment. Empirical expression for the copper electrical conductivity is presented. Parameters in this expression is fit on every of two equations of state. Map of copper conductivity is plotted.

  1. Effect of alkali cations on two-dimensional networks of two new quaternary thioarsenates (III) prepared by a facile surfactant-thermal method

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Dongming [School of Civil and Architectural Engineering, Zhejiang University, Hangzhou 310058 (China); Hou, Peipei; Liu, Chang [State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Chai, Wenxiang [College of Materials Science and Engineering, China Jiliang University, Hangzhou 310018 (China); Zheng, Xuerong [State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Zhang, Luodong [School of Civil and Architectural Engineering, Zhejiang University, Hangzhou 310058 (China); Zhi, Mingjia; Zhou, Chunmei [State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Liu, Yi, E-mail: liuyimse@zju.edu.cn [State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China)

    2016-09-15

    Two new quaternary thioarsenates(III) NaAg{sub 2}AsS{sub 3}·H{sub 2}O (1) and KAg{sub 2}AsS{sub 3} (2) with high yields have been successfully prepared through a facile surfactant-thermal method. It is interesting that 2 can only be obtained with the aid of ethanediamine (en), which indicates that weak basicity of solvent is beneficial to the growth of 2 compared with 1. Both 1 and 2 feature the similar two-dimensional (2D) layer structures. However, the distortion of the primary honeycomb-like nets in 2 is more severe than that of 1, which demonstrates that Na{sup +} and K{sup +} cations have different structure directing effects on these two thioarsenates(III). Both experimental and theoretical studies confirm 1 and 2 are semiconductors with band gaps in the visible region. Our success in preparing these two quaternary thioarsenates(III) proves that surfactant-thermal technique is a powerful yet facile synthetic method to explore new complex chalcogenides. - Graphical abstract: Two new quaternary thioarsenates(III) NaAg{sub 2}AsS{sub 3}·H{sub 2}O (1) and KAg{sub 2}AsS{sub 3} (2) with high yields have been successfully prepared through a facile surfactant-thermal method. X-ray single crystal diffraction analyses demonstrate that Na{sup +} and K{sup +} cations have different structure directing effects on these two thioarsenates(III). Both experimental and theoretical studies confirm 1 and 2 are semiconductors with band gaps in the visible region. Display Omitted - Highlights: • NaAg{sub 2}AsS{sub 3}⋅H{sub 2}O (1) and KAg{sub 2}AsS{sub 3} (2) were prepared through surfactant-thermal method. • Crystal structures show Na{sup ±} and K{sup ±} have different structure directing effects. • The weak basicity of solvent is benefit to the growth of 2 compared with 1. • Experimental and theoretical studies confirm 1 and 2 are semiconductors.

  2. The thermo-electric nature of the Debye temperature

    Directory of Open Access Journals (Sweden)

    Mithun Bhowmick

    2018-05-01

    Full Text Available The Debye temperature is typically associated with the heat capacity of a solid and the cut-off of the possible lattice vibrations, but not necessarily to the electric conductivity of the material. By investigating III-V and II-VI compound semiconductors, we reveal that the Debye temperature represents a thermo-electric material parameter, connecting the thermal and electronic properties of a solid via a distinct power law.

  3. Complexes of lanthanum(III), cerium(III), samarium(III) and dysprosium(III) with substituted piperidines

    Energy Technology Data Exchange (ETDEWEB)

    Manhas, B S; Trikha, A K; Singh, H; Chander, M

    1983-11-01

    Complexes of the general formulae M/sub 2/Cl/sub 6/(L)/sub 3/.C/sub 2/H/sub 5/OH and M/sub 2/(NO/sub 3/)/sub 6/(L)/sub 2/.CH/sub 3/OH have been synthesised by the reactions of chlorides and nitrates of La(III), Ce(III), Sm(III) and Dy(III) with 2-methylpiperidine, 3-methylpiperidine and 4-methylpiperidine. These complexes have been characterised on the basis of their elemental analysis, and IR and electronic reflectance spectra. IR spectral data indicate the presence of coordinated ethanol and methanol molecules and bidentate nitrate groups. Coordination numbers of the metal ions vary from 5 to 8. 19 refs.

  4. SMORN-III benchmark test on reactor noise analysis methods

    International Nuclear Information System (INIS)

    Shinohara, Yoshikuni; Hirota, Jitsuya

    1984-02-01

    A computational benchmark test was performed in conjunction with the Third Specialists Meeting on Reactor Noise (SMORN-III) which was held in Tokyo, Japan in October 1981. This report summarizes the results of the test as well as the works made for preparation of the test. (author)

  5. The structure and control method of hybrid power source for electric vehicle

    International Nuclear Information System (INIS)

    Li, Maobing; Xu, Hui; Li, Weimin; Liu, Yin; Li, Fade; Hu, Yue; Liu, Li

    2016-01-01

    In this paper, an electric vehicle powertrain configuration is presented, which the lithium-ion battery integrated with ultracapacitors is developed as the hybrid power system to improve the transient performance of an electric vehicle, and to decrease the damage to the battery pack. In the proposed system, a bidirectional direct current/direct current converter is used to couple the ultracapacitors bank to the main battery pack. The energy management strategy based on fuzzy logic for hybrid power system has been proposed to promote the performance of energy flow in the electric vehicle. The experiment results in urban driving cycles show remarkable advantages of the proposed hybrid system configuration and energy management strategy. About 30% of the battery capacity energy is saved while using the hybrid power source. Besides, the voltage and current curves of battery become smoother than that with the single power. - Highlights: • A hybrid power source electric vehicle powertrain configuration is presented. • The energy management strategy based on fuzzy logic is proposed. • The experiment results show remarkable advantages of the configuration and method.

  6. Multiple Signal Classification Algorithm Based Electric Dipole Source Localization Method in an Underwater Environment

    Directory of Open Access Journals (Sweden)

    Yidong Xu

    2017-10-01

    Full Text Available A novel localization method based on multiple signal classification (MUSIC algorithm is proposed for positioning an electric dipole source in a confined underwater environment by using electric dipole-receiving antenna array. In this method, the boundary element method (BEM is introduced to analyze the boundary of the confined region by use of a matrix equation. The voltage of each dipole pair is used as spatial-temporal localization data, and it does not need to obtain the field component in each direction compared with the conventional fields based localization method, which can be easily implemented in practical engineering applications. Then, a global-multiple region-conjugate gradient (CG hybrid search method is used to reduce the computation burden and to improve the operation speed. Two localization simulation models and a physical experiment are conducted. Both the simulation results and physical experiment result provide accurate positioning performance, with the help to verify the effectiveness of the proposed localization method in underwater environments.

  7. Reconstruction of electrical impedance tomography (EIT) images based on the expectation maximum (EM) method.

    Science.gov (United States)

    Wang, Qi; Wang, Huaxiang; Cui, Ziqiang; Yang, Chengyi

    2012-11-01

    Electrical impedance tomography (EIT) calculates the internal conductivity distribution within a body using electrical contact measurements. The image reconstruction for EIT is an inverse problem, which is both non-linear and ill-posed. The traditional regularization method cannot avoid introducing negative values in the solution. The negativity of the solution produces artifacts in reconstructed images in presence of noise. A statistical method, namely, the expectation maximization (EM) method, is used to solve the inverse problem for EIT in this paper. The mathematical model of EIT is transformed to the non-negatively constrained likelihood minimization problem. The solution is obtained by the gradient projection-reduced Newton (GPRN) iteration method. This paper also discusses the strategies of choosing parameters. Simulation and experimental results indicate that the reconstructed images with higher quality can be obtained by the EM method, compared with the traditional Tikhonov and conjugate gradient (CG) methods, even with non-negative processing. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  8. The Effect of Pressure and Temperature on Separation of Free Gadolinium(III) From Gd-DTPA Complex by Nanofiltration-Complexation Method

    Science.gov (United States)

    Rahayu, Iman; Anggraeni, Anni; Ukun, MSS; Bahti, Husein H.

    2017-05-01

    Nowdays, the utilization of rare earth elements has been carried out widely in industry and medicine, one of them is gadolinium in Gd-DTPA complex is used as a contrast agent in a magnetic resonance imaging (MRI) diagnostic to increase the visual contrast between normal tissue and diseased. Although the stability of a given complex may be high enough, the complexation step couldnot have been completed, so there is possible to gadolinium(III) in the complex compound. Therefore, the function of that compounds should be dangerous because of the toxicity of gadolinium(III) in human body. So, it is necessarry to separate free gadolinium(III) from Gd-DTPA complex by nanofiltration-complexation. The method of this study is complexing of Gd2O3 with DTPA ligand by reflux and separation of Gd-DTPA complex from gadolinium(III) with a nanofiltration membrane on the variation of pressures(2, 3, 4, 5, 6 bars) and temperature (25, 30, 35, 40 °C) and determined the flux and rejection. The results of this study are the higher of pressures and temperatures, permeation flux are increasing and ion rejections are decreasing and gave the free gadolinium(III) rejection until 86.26%.

  9. Mixed price and load forecasting of electricity markets by a new iterative prediction method

    International Nuclear Information System (INIS)

    Amjady, Nima; Daraeepour, Ali

    2009-01-01

    Load and price forecasting are the two key issues for the participants of current electricity markets. However, load and price of electricity markets have complex characteristics such as nonlinearity, non-stationarity and multiple seasonality, to name a few (usually, more volatility is seen in the behavior of electricity price signal). For these reasons, much research has been devoted to load and price forecast, especially in the recent years. However, previous research works in the area separately predict load and price signals. In this paper, a mixed model for load and price forecasting is presented, which can consider interactions of these two forecast processes. The mixed model is based on an iterative neural network based prediction technique. It is shown that the proposed model can present lower forecast errors for both load and price compared with the previous separate frameworks. Another advantage of the mixed model is that all required forecast features (from load or price) are predicted within the model without assuming known values for these features. So, the proposed model can better be adapted to real conditions of an electricity market. The forecast accuracy of the proposed mixed method is evaluated by means of real data from the New York and Spanish electricity markets. The method is also compared with some of the most recent load and price forecast techniques. (author)

  10. Inner-sphere and outer-sphere complexes of yttrium(III), lanthanum (III), neodymium(III), terbium(III) and thulium(III) with halide ions in N,N-dimethylformamide

    International Nuclear Information System (INIS)

    Takahashi, Ryouta; Ishiguro, Shin-ichi

    1991-01-01

    The formation of chloro, bromo and iodo complexes of yttrium(III), and bromo and iodo complexes of lanthanum(III), neodymium(III), terbium(III) and thulium(III) has been studied by precise titration calorimetry in N,N-dimethylformamide (DMF) at 25 o C. The formation of [YCl] 2+ , [YCl 2 ] + , [YCl 3 ] and [YCl 4 ] - , and [MBr] 2+ and [MBr 2 ] + (M = Y, La, Nd, Tb, Tm) was revealed, and their formation constants, enthalpies and entropies were determined. It is found that the formation enthalpies change in the sequence ΔH o (Cl) > ΔH o (l), which is unusual for hard metal (III) ions. This implies that, unlike the chloride ion, the bromide ion forms outer-sphere complexes with the lanthanide(III) and yttrium(III) ions in DMF. Evidence for either an inner- or outer-sphere complex was obtained from 89 Y NMR spectra for Y(ClO 4 ) 3 , YCl 3 and YBr 3 DMF solutions at room temperature. (author)

  11. Detection and observation of deep vein thromboses by physical, radiological and electrical methods

    International Nuclear Information System (INIS)

    Bonafous, J.; Constantinesco, A.; Meyer, P.; Bidet, R.; Healy, J.C.; Chambron, J.; Lobera, A.; Chopin, J.

    1975-01-01

    The method of thrombosis detection by iodine 131-labelled exogenous fibrinogen was evaluated by comparison with three physical methods: an isotopic method using selenomethionine-labelled endogenous fibrinogen, phlebography, phletysmography by electrical impedance. The results confirm the superiority of the isotopic method with regard to efficiency and comfort for the patient. Under certain conditions the frequency of positive tests was the same with selenomethionine as with exogenous fibrinogen [fr

  12. Assessment and Improving Methods of Reliability Indices in Bakhtar Regional Electricity Company

    Directory of Open Access Journals (Sweden)

    Saeed Shahrezaei

    2013-04-01

    Full Text Available Reliability of a system is the ability of a system to do prospected duties in future and the probability of desirable operation for doing predetermined duties. Power system elements failures data are the main data of reliability assessment in the network. Determining antiseptic parameters is the goal of reliability assessment by using system history data. These parameters help to recognize week points of the system. In other words, the goal of reliability assessment is operation improving and decreasing of the failures and power outages. This paper is developed to assess reliability indices of Bakhtar Regional Electricity Company up to 1393 and the improving methods and their effects on the reliability indices in this network. DIgSILENT Power Factory software is employed for simulation. Simulation results show the positive effect of improving methods in reliability indices of Bakhtar Regional Electricity Company.

  13. A new cascade NN based method to short-term load forecast in deregulated electricity market

    International Nuclear Information System (INIS)

    Kouhi, Sajjad; Keynia, Farshid

    2013-01-01

    Highlights: • We are proposed a new hybrid cascaded NN based method and WT to short-term load forecast in deregulated electricity market. • An efficient preprocessor consist of normalization and shuffling of signals is presented. • In order to select the best inputs, a two-stage feature selection is presented. • A new cascaded structure consist of three cascaded NNs is used as forecaster. - Abstract: Short-term load forecasting (STLF) is a major discussion in efficient operation of power systems. The electricity load is a nonlinear signal with time dependent behavior. The area of electricity load forecasting has still essential need for more accurate and stable load forecast algorithm. To improve the accuracy of prediction, a new hybrid forecast strategy based on cascaded neural network is proposed for STLF. This method is consists of wavelet transform, an intelligent two-stage feature selection, and cascaded neural network. The feature selection is used to remove the irrelevant and redundant inputs. The forecast engine is composed of three cascaded neural network (CNN) structure. This cascaded structure can be efficiently extract input/output mapping function of the nonlinear electricity load data. Adjustable parameters of the intelligent feature selection and CNN is fine-tuned by a kind of cross-validation technique. The proposed STLF is tested on PJM and New York electricity markets. It is concluded from the result, the proposed algorithm is a robust forecast method

  14. A general modeling method for I-V characteristics of geometrically and electrically configured photovoltaic arrays

    International Nuclear Information System (INIS)

    Liu Guangyu; Nguang, Sing Kiong; Partridge, Ashton

    2011-01-01

    Highlights: → A novel and general method is proposed for modeling PV arrays or modules. → A robust algorithm is used for the first time to improve the convergence to solution. → Auxiliary functions in other general methods are not compulsory in our method. → It is novel that geometric configuration is also incorporated. → A case study is performed to show the approach's advantages and unique features. - Abstract: A general method for modeling typical photovoltaic (PV) arrays and modules is proposed to find the exact current and voltage relationship of PV arrays or modules of geometrically and electrically different configurations. Nonlinear characteristic equations of electrical devices in solar array or module systems are numerically constructed without adding any virtual electrical components. Then, a robust damped Newton method is used to find exact I-V relationship of these general nonlinear equations, where the convergence is guaranteed. The model can deal with different mismatch effects such as different configurations of bypass diodes, and partial shading. Geometry coordinates of PV components are also considered to facilitate the modeling of the actual physical configuration. Simulation of a PV array with 48 modules, partially shaded by a concrete structure, is performed to verify the effectiveness and advantages of the proposed method.

  15. Review of Electrical and Gravity Methods of Near-Surface Exploration for Groundwater

    Directory of Open Access Journals (Sweden)

    W. O. Raji

    2014-12-01

    Full Text Available The theory and practice of electrical and gravity methods of geophysics for groundwater exploration was reviewed with illustrations and data examples. With the goal of reducing cases of borehole/water-well failure attributed to the lack of the knowledge of the methods of geophysics for groundwater exploration and development, the paper reviews the basic concepts, field procedures for data acquisition, data processing, and interpretation as applied to the subject matter. Given a case study of groundwater exploration in University of Ilorin Campus, the three important techniques of electrical method of groundwater exploration are explained and illustrated using field data obtained in a previous study. Interpretation of resistivity data shows that an area measuring low resistivity (high conductivity, having thick pile of unconsolidated rock, and underlained by fracture crystalline is a ‘bright spot’ for citing borehole for groundwater abstraction in a basement complex area. Further to this, gravity method of groundwater exploration was discussed with field data from Wokbedilo community in Ethopia. Bouguer and reduced gravity anomaly results were presented as maps and contours to demonstrate how gravity data can be inverted to map groundwater aquifers and subsurface geological structures during groundwater exploration.

  16. Towards Electrically Pumped Nanolasers for Terabit Communication

    DEFF Research Database (Denmark)

    Lupi, Alexandra

    This thesis deals with modeling, design, fabrication and characterization of vertically electrically pumped photonic crystal light-emitting devices. For this purpose a new material platform of III-V semiconductors on silicon has been developed. The devices fabricated on this platform can be used...... as optical interconnects, where compatibility with Complementary Metal Oxide Semiconductor (CMOS) technology is required. The first part of this work is dedicated to modeling and simulations of electrically pumped photonic crystal nanolasers with diverse material configurations and different concepts...... for electrical injection. The analysis of the models is conducted with focus on laser performances, energy efficiency, and thermal properties. The second part of this thesis deals with design, fabrication and characterization of vertically electrically pumped photonic crystal light-emitting devices. The devices...

  17. A bid solicitation and selection method for developing a competitive spot priced electric market

    International Nuclear Information System (INIS)

    Ancona, J.J.

    1997-01-01

    The electric utility industry is in the beginning throes of a transformation from a cost-based regulated structure to a more market based less regulated system. Traditional unit commitment and economic dispatch methodologies can continue to provide reliable least-cost solutions, providing they are modified to accommodate a larger sphere of market participants. This paper offers a method for an entity such as an Independent System Operator (ISO) to solicit and evaluate bids for developing a spot priced electric market by replicating existing utility practices that are effective and efficient, while creating an open and equitable competitive marketplace for electricity

  18. Congestion management of electric distribution networks through market based methods

    DEFF Research Database (Denmark)

    Huang, Shaojun

     EVs and HPs. Market-based congestion management methods are the focus of the thesis. They handle the potential congestion at the energy planning stage; therefore, the aggregators can optimally plan the energy consumption and have the least impact on the customers. After reviewing and identifying...... the shortcomings of the existing methods, the thesis fully studies and improves the dynamic tariff (DT) method, and proposes two  new market-based  congestion management methods,  namely the  dynamic subsidy (DS) method and the flexible demand swap method. The thesis improves the DT method from four aspects......Rapidly increasing share of intermittent renewable energy production poses a great challenge of the management and operation of the modern power systems. Deployment of a large number of flexible demands, such as electrical vehicles (EVs) and heat pumps (HPs), is believed to be a promising solution...

  19. Signal processing methods for reducing artifacts in microelectrode brain recordings caused by functional electrical stimulation

    Science.gov (United States)

    Young, D.; Willett, F.; Memberg, W. D.; Murphy, B.; Walter, B.; Sweet, J.; Miller, J.; Hochberg, L. R.; Kirsch, R. F.; Ajiboye, A. B.

    2018-04-01

    Objective. Functional electrical stimulation (FES) is a promising technology for restoring movement to paralyzed limbs. Intracortical brain-computer interfaces (iBCIs) have enabled intuitive control over virtual and robotic movements, and more recently over upper extremity FES neuroprostheses. However, electrical stimulation of muscles creates artifacts in intracortical microelectrode recordings that could degrade iBCI performance. Here, we investigate methods for reducing the cortically recorded artifacts that result from peripheral electrical stimulation. Approach. One participant in the BrainGate2 pilot clinical trial had two intracortical microelectrode arrays placed in the motor cortex, and thirty-six stimulating intramuscular electrodes placed in the muscles of the contralateral limb. We characterized intracortically recorded electrical artifacts during both intramuscular and surface stimulation. We compared the performance of three artifact reduction methods: blanking, common average reference (CAR) and linear regression reference (LRR), which creates channel-specific reference signals, composed of weighted sums of other channels. Main results. Electrical artifacts resulting from surface stimulation were 175  ×  larger than baseline neural recordings (which were 110 µV peak-to-peak), while intramuscular stimulation artifacts were only 4  ×  larger. The artifact waveforms were highly consistent across electrodes within each array. Application of LRR reduced artifact magnitudes to less than 10 µV and largely preserved the original neural feature values used for decoding. Unmitigated stimulation artifacts decreased iBCI decoding performance, but performance was almost completely recovered using LRR, which outperformed CAR and blanking and extracted useful neural information during stimulation artifact periods. Significance. The LRR method was effective at reducing electrical artifacts resulting from both intramuscular and surface FES, and

  20. Application of Electrical Resistivity Method (ERM) in Groundwater Exploration

    Science.gov (United States)

    Izzaty Riwayat, Akhtar; Nazri, Mohd Ariff Ahmad; Hazreek Zainal Abidin, Mohd

    2018-04-01

    The geophysical method which dominant by geophysicists become one of most popular method applied by engineers in civil engineering fields. Electrical Resistivity Method (ERM) is one of geophysical tool that offer very attractive technique for subsurface profile characterization in larger area. Applicable alternative technique in groundwater exploration such as ERM which complement with existing conventional method may produce comprehensive and convincing output thus effective in terms of cost, time, data coverage and sustainable. ERM has been applied by various application in groundwater exploration. Over the years, conventional method such as excavation and test boring are the tools used to obtain information of earth layer especially during site investigation. There are several problems regarding the application of conventional technique as it only provides information at actual drilling point only. This review paper was carried out to expose the application of ERM in groundwater exploration. Results from ERM could be additional information to respective expert for their problem solving such as the information on groundwater pollution, leachate, underground and source of water supply.

  1. Method to probe the electrical activity of dislocations in non-intentionally doped n-GaN

    Energy Technology Data Exchange (ETDEWEB)

    Mimila-Arroyo, J., E-mail: jmimila@cinvestav.mx [Centro de Investigacion y de Estudios Avanzados del Instituto Politecnico Nacional, Av. Instituto Politecnico Nacional No 2508, Mexico D.F., CP 07360 (Mexico); Morales, E. [Centro de Investigacion y de Estudios Avanzados del Instituto Politecnico Nacional, Av. Instituto Politecnico Nacional No 2508, Mexico D.F., CP 07360 (Mexico); Lusson, A. [Groupe d' Etudes de la Matiere Condensee, Universite de Versailles, CNRS (UMR 8635), Batiment FERMAT, 45, Avenue des Etats-Unis, 78035 Versailles (France)

    2012-09-20

    Highlights: Black-Right-Pointing-Pointer This is the first method proposed to probe the electrical activity of dislocations. Black-Right-Pointing-Pointer Based on Hall and resistivity measurements under sub-bad gap illumination. High sensitivity to the charge contained at the dislocations. Black-Right-Pointing-Pointer Is non destructive. Black-Right-Pointing-Pointer And can be applied at some point in the processing of samples and devices. - Abstract: Here is presented a method to probe the electrical activity of dislocations in non-intentionally doped n-GaN epitaxial layers based on the study of their sub-band gap photoconductivity, monitoring their electron concentration and mobility. Non-intentionally doped n-GaN layers bearing charged and thus highly dispersive and recombining dislocations when illuminated with sub-band gap photons show a strong increase on their conductivity, due to an equivalent increase on the electron mobility while the electron concentration remains unchanged. On the other side, non-intentionally doped n-GaN layers bearing electrically inactive dislocations display almost no photoconduction, as both; carrier concentration and their mobility remain unchanged under the same illumination conditions. The method, simultaneously assess the electrical activity of dislocations and the material quality, and can be applied to any other semiconducting material bearing high dislocations densities.

  2. Improved method for measuring the electric fields in microwave cavity resonators

    International Nuclear Information System (INIS)

    Amato, J.C.; Herrmann, H.

    1985-01-01

    The electric field distribution in microwave cavities is commonly measured by frequency perturbation techniques. For many cavity modes which are important in accelerator applications, the standard bead-pulling technique cannot provide adequate discrimination between fields parallel and perpendicular to the particle trajectory, leading to inaccurate and ambiguous results. A method is described which substantially increases the directivity of the measurements. The method has been successfully used to determine the accelerator-related cavity parameters at frequencies up to three times the fundamental resonant frequency

  3. Comparison of electrical conductivity calculation methods for natural waters

    Science.gov (United States)

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Ryan, Joseph N.

    2012-01-01

    The capability of eleven methods to calculate the electrical conductivity of a wide range of natural waters from their chemical composition was investigated. A brief summary of each method is presented including equations to calculate the conductivities of individual ions, the ions incorporated, and the method's limitations. The ability of each method to reliably predict the conductivity depends on the ions included, effective accounting of ion pairing, and the accuracy of the equation used to estimate the ionic conductivities. The performances of the methods were evaluated by calculating the conductivity of 33 environmentally important electrolyte solutions, 41 U.S. Geological Survey standard reference water samples, and 1593 natural water samples. The natural waters tested include acid mine waters, geothermal waters, seawater, dilute mountain waters, and river water impacted by municipal waste water. The three most recent conductivity methods predict the conductivity of natural waters better than other methods. Two of the recent methods can be used to reliably calculate the conductivity for samples with pH values greater than about 3 and temperatures between 0 and 40°C. One method is applicable to a variety of natural water types with a range of pH from 1 to 10, temperature from 0 to 95°C, and ionic strength up to 1 m.

  4. Iterative Dipole Moment Method for the Dielectrophoretic Particle-Particle Interaction in a DC Electric Field

    Directory of Open Access Journals (Sweden)

    Qing Zhang

    2018-01-01

    Full Text Available Electric force is the most popular technique for bioparticle transportation and manipulation in microfluidic systems. In this paper, the iterative dipole moment (IDM method was used to calculate the dielectrophoretic (DEP forces of particle-particle interactions in a two-dimensional DC electric field, and the Lagrangian method was used to solve the transportation of particles. It was found that the DEP properties and whether the connection line between initial positions of particles perpendicular or parallel to the electric field greatly affect the chain patterns. In addition, the dependence of the DEP particle interaction upon the particle diameters, initial particle positions, and the DEP properties have been studied in detail. The conclusions are advantageous in elelctrokinetic microfluidic systems where it may be desirable to control, manipulate, and assemble bioparticles.

  5. Subsurface imaging by electrical and EM methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    This report consists of 3 subjects. 1) Three dimensional inversion of resistivity data with topography : In this study, we developed a 3-D inversion method based on the finite element calculation of model responses, which can effectively accommodate the irregular topography. In solving the inverse problem, the iterative least-squares approach comprising the smoothness-constraints was taken along with the reciprocity approach in the calculation of Jacobian. Furthermore the Active Constraint Balancing, which has been recently developed by ourselves to enhance the resolving power of the inverse problem, was also employed. Since our new algorithm accounts for the topography in the inversion step, topography correction is not necessary as a preliminary processing and we can expect a more accurate image of the earth. 2) Electromagnetic responses due to a source in the borehole : The effects of borehole fluid and casing on the borehole EM responses should thoroughly be analyzed since they may affect the resultant image of the earth. In this study, we developed an accurate algorithm for calculating the EM responses containing the effects of borehole fluid and casing when a current-carrying ring is located on the borehole axis. An analytic expression for primary vertical magnetic field along the borehole axis was first formulated and the fast Fourier transform is to be applied to get the EM fields at any location in whole space. 3) High frequency electromagnetic impedance survey : At high frequencies the EM impedance becomes a function of the angle of incidence or the horizontal wavenumber, so the electrical properties cannot be readily extracted without first eliminating the effect of horizontal wavenumber on the impedance. For this purpose, this paper considers two independent methods for accurately determining the horizontal wavenumber, which in turn is used to correct the impedance data. The 'apparent' electrical properties derived from the corrected impedance

  6. Hybrid III-V-on-Si Vertical Cavity laser for Optical Interconnects

    DEFF Research Database (Denmark)

    Park, Gyeong Cheol; Semenova, Elizaveta; Chung, Il-Sug

    2013-01-01

    Combining a III-V active material onto the Si platform is an attractive approach for silicon photonics light source. We have developed fabrication methods for novel III-V on Si vertical cavity lasers.......Combining a III-V active material onto the Si platform is an attractive approach for silicon photonics light source. We have developed fabrication methods for novel III-V on Si vertical cavity lasers....

  7. Research on industrialization of electric vehicles with its demand forecast using exponential smoothing method

    Directory of Open Access Journals (Sweden)

    Zhanglin Peng

    2015-04-01

    Full Text Available Purpose: Electric vehicles industry has gotten a rapid development in the world, especially in the developed countries, but still has a gap among different countries or regions. The advanced industrialization experiences of the EVs in the developed countries will have a great helpful for the development of EVs industrialization in the developing countries. This paper seeks to research the industrialization path & prospect of American EVs by forecasting electric vehicles demand and its proportion to the whole car sales based on the historical 37 EVs monthly sales and Cars monthly sales spanning from Dec. 2010 to Dec. 2013, and find out the key measurements to help Chinese government and automobile enterprises to promote Chinese EVs industrialization. Design/methodology: Compared with Single Exponential Smoothing method and Double Exponential Smoothing method, Triple exponential smoothing method is improved and applied in this study. Findings: The research results show that:  American EVs industry will keep a sustained growth in the next 3 months.  Price of the EVs, price of fossil oil, number of charging station, EVs technology and the government market & taxation polices have a different influence to EVs sales. So EVs manufacturers and policy-makers can adjust or reformulate some technology tactics and market measurements according to the forecast results. China can learn from American EVs polices and measurements to develop Chinese EVs industry. Originality/value: The main contribution of this paper is to use the triple exponential smoothing method to forecast the electric vehicles demand and its proportion to the whole automobile sales, and analyze the industrial development of Chinese electric vehicles by American EVs industry.

  8. Methods for Analyzing Electric Load Shape and its Variability

    Energy Technology Data Exchange (ETDEWEB)

    Price, Philip

    2010-05-12

    Current methods of summarizing and analyzing electric load shape are discussed briefly and compared. Simple rules of thumb for graphical display of load shapes are suggested. We propose a set of parameters that quantitatively describe the load shape in many buildings. Using the example of a linear regression model to predict load shape from time and temperature, we show how quantities such as the load?s sensitivity to outdoor temperature, and the effectiveness of demand response (DR), can be quantified. Examples are presented using real building data.

  9. Research of Electrical Conductivity Measurement System for Mine Bursting Water Based on Dual Frequency Method

    Directory of Open Access Journals (Sweden)

    Zhou Mengran

    2016-01-01

    Full Text Available This paper presents a double frequency conductivity measurement method for measuring mine bursting water, to solve the capacitance effect of the conductivity sensor itself has the help. The core controller of the system is the single chip microcomputer ATMEGA128. This paper introduces the basic principle of the measurement of the existing problems and the dual frequency measurement method, and then introduces and analyzes the hardware. To test and analyze the collected data, the double frequency method is found to have good stability and accuracy in the measurement of the electrical conductivity of mine inrush water. It is proved that the method and the system design of the hardware circuit can accurately measure the electric conductivity of the mine inrush water source.

  10. Rapid and Checkable Electrical Post-Treatment Method for Organic Photovoltaic Devices

    Science.gov (United States)

    Park, Sangheon; Seo, Yu-Seong; Shin, Won Suk; Moon, Sang-Jin; Hwang, Jungseek

    2016-01-01

    Post-treatment processes improve the performance of organic photovoltaic devices by changing the microscopic morphology and configuration of the vertical phase separation in the active layer. Thermal annealing and solvent vapor (or chemical) treatment processes have been extensively used to improve the performance of bulk-heterojunction (BHJ) organic photovoltaic (OPV) devices. In this work we introduce a new post-treatment process which we apply only electrical voltage to the BHJ-OPV devices. We used the commercially available P3HT [Poly(3-hexylthiophene)] and PC61BM (Phenyl-C61-Butyric acid Methyl ester) photovoltaic materials as donor and acceptor, respectively. We monitored the voltage and current applied to the device to check for when the post-treatment process had been completed. This electrical treatment process is simpler and faster than other post-treatment methods, and the performance of the electrically treated solar cell is comparable to that of a reference (thermally annealed) device. Our results indicate that the proposed treatment process can be used efficiently to fabricate high-performance BHJ-OPV devices. PMID:26932767

  11. Dynamic Fuzzy Clustering Method for Decision Support in Electricity Markets Negotiation

    Directory of Open Access Journals (Sweden)

    Ricardo FAIA

    2016-10-01

    Full Text Available Artificial Intelligence (AI methods contribute to the construction of systems where there is a need to automate the tasks. They are typically used for problems that have a large response time, or when a mathematical method cannot be used to solve the problem. However, the application of AI brings an added complexity to the development of such applications. AI has been frequently applied in the power systems field, namely in Electricity Markets (EM. In this area, AI applications are essentially used to forecast / estimate the prices of electricity or to search for the best opportunity to sell the product. This paper proposes a clustering methodology that is combined with fuzzy logic in order to perform the estimation of EM prices. The proposed method is based on the application of a clustering methodology that groups historic energy contracts according to their prices’ similarity. The optimal number of groups is automatically calculated taking into account the preference for the balance between the estimation error and the number of groups. The centroids of each cluster are used to define a dynamic fuzzy variable that approximates the tendency of contracts’ history. The resulting fuzzy variable allows estimating expected prices for contracts instantaneously and approximating missing values in the historic contracts.

  12. Field distribution and DNA transport in solid tumors during electric field-mediated gene delivery.

    Science.gov (United States)

    Henshaw, Joshua W; Yuan, Fan

    2008-02-01

    Gene therapy has a great potential in cancer treatment. However, the efficacy of cancer gene therapy is currently limited by the lack of a safe and efficient means to deliver therapeutic genes into the nucleus of tumor cells. One method under investigation for improving local gene delivery is based on the use of pulsed electric field. Despite repeated demonstration of its effectiveness in vivo, the underlying mechanisms behind electric field-mediated gene delivery remain largely unknown. Without a thorough understanding of these mechanisms, it will be difficult to further advance the gene delivery. In this review, the electric field-mediated gene delivery in solid tumors will be examined by following individual transport processes that must occur in vivo for a successful gene transfer. The topics of examination include: (i) major barriers for gene delivery in the body, (ii) distribution of electric fields at both cell and tissue levels during the application of external fields, and (iii) electric field-induced transport of genes across each of the barriers. Through this approach, the review summarizes what is known about the mechanisms behind electric field-mediated gene delivery and what require further investigations in future studies.

  13. Comparison of the General Electric BWR/6 standard plant design to the IAEA NUSS codes and guides

    International Nuclear Information System (INIS)

    D'Ardenne, W.H.; Sherwood, G.G.

    1985-01-01

    The General Electric BWR/6 Mark III standard plant design meets or exceeds current requirements of published International Atomic Energy Agency (IAEA) Nuclear Safety Standards (NUSS) codes and guides. This conclusion is based on a review of the NUSS codes and guides by General Electric and by the co-ordinated US review of the NUSS codes and guides during their development. General Electric compared the published IAEA NUSS codes and guides with the General Electric design. The applicability of each code and guide to the BWR/6 Mark III standard plant design was determined. Each code or guide was reviewed by a General Electric engineer knowledgeable about the structures, systems and components addressed and the technical area covered by that code or guide. The results of this review show that the BWR/6 Mark III standard plant design meets or exceeds the applicable requirements of the published IAEA NUSS codes and guides. The co-ordinated US review of the IAEA NUSS codes and guides corroborates the General Electric review. In the co-ordinated US review, the USNRC and US industry organizations (including General Electric) review the NUSS codes and guides during their development. This review ensures that the NUSS codes and guides are consistent with the current US government regulations, guidance and regulatory practices, US voluntary industry codes and standards, and accepted US industry design, construction and operational practices. If any inconsistencies are identified, comments are submitted to the IAEA by the USNRC. All US concerns submitted to the IAEA have been resolved. General Electric design reviews and the Final Design Approval (FDA) issued by the USNRC have verified that the General Electric BWR/6 Mark III standard plant design meets or exceeds the current US requirements, guidance and practices. Since these requirements, guidance and practices meet or exceed those of the NUSS codes and guides, so does the General Electric design. (author)

  14. Application of equivalent electrodes method to analysis of interaction between ELF-LF electric fields and human body

    International Nuclear Information System (INIS)

    Ceselkoska, Vesna C.; Velickovic, Dragutin M.

    2002-01-01

    This paper presents the use of equivalent electrodes method, numerical method, based on surface-charge equation to quantify the interaction of low frequencies electric fields with various models of human body. The evaluation of the electric field intensity on the body surface is performed for a realistic model of the human body. Several examples for different postures of the model are given. (Author)

  15. Studies of Binary Complexes of Tripodal Ligand cis,cis-1,3,5-tris(methylaminocyclohexane with Cr(III and Fe(III

    Directory of Open Access Journals (Sweden)

    S. Esakki Muthu

    2005-01-01

    Full Text Available The formation of binary complexes of Cr(III and Fe(III with a tripodal ligand cis,cis-1,3,5-tris(methylaminocyclohexane (tmach (L has been investigated in solution. The overall stability constants of tmach with Cr(III and Fe(III were determined by potentiometric method at an ionic strength of 0.1 M NaClO4 at 25±1°C in aqueous medium. The formation of species like MLH25+, MLH4+, ML3+, ML(OH2+ and ML(OH3 were observed. Fe(III was found to form more stable complexes than Cr(III. Molecular mechanics calculations were performed to explain the mode of coordination in solution.

  16. Boundary element numerical method for the electric field generated by oblique multi-needle electrodes

    Institute of Scientific and Technical Information of China (English)

    LIU FuPing; WANG AnLing; WANG AnXuan; CAO YueZu; CHEN Qiang; YANG ChangChun

    2009-01-01

    According to the electric potential of oblique multi-needle electrodes (OMNE) in biological tissue, the discrete equations based on the indetermination linear current density were established by the boundary element integral equations (BEIE). The non-uniform distribution of the current flowing from multi-needle electrodes to conductive biological tissues was imaged by solving a set of linear equa-tions. Then, the electric field and potential generated by OMNE in biological tissues at any point may be determined through the boundary element method (BEM). The time of program running and stability of computing method are examined by an example. It demonstrates that the algorithm possesses a quick speed and the steady computed results. It means that this method has an important referenced significance for computing the field and the potential generated by OMNE in bio-tissue, which is a fast, effective and accurate computing method.

  17. A State of the Art Review- Methods to Evaluate Electrical Performance of Composite Cross-arms and Composite-based Pylons

    DEFF Research Database (Denmark)

    Wang, Qian; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    A novel uni-body composite pylon has been proposed for 400 kV transmission lines with advantages of compacted size, friendly looking and cost competitiveness. As its configuration is quite different from the traditional lattice pylon, its electrical performance needs in-depth investigation...... and evaluation, for which electrical testing methods are essential. However, as research on composite-based pylons is still in initial stage, leaving international standards and theoretical analysis on this topic very limited, effective testing methods to evaluate the fully composite pylon’s electrical...... performance need to be studied. This paper sums up experience and key advances on testing methods to evaluate electrical performance of composite cross-arms and composite-based pylons. Based on state of the art review, several feasible testing methods that can be used to verify the feasibility of the novel...

  18. Aplicación del método Electre III en la clasificación de clústeres de artesanías

    Directory of Open Access Journals (Sweden)

    Fabricio Molica de Mendonça

    2011-01-01

    Full Text Available En el presente artículo se muestran los resultados del estudio que busca aplicar el método Electre III para clasificar cuatro aglomerados productivos de micro y pequeñas empresas, localizados en el Estado de Minas Gerais (Brasil, en relación con la capacidad de desarrollar estrategias de supervivencia, por medio de relaciones con proveedores, clientes y distribuidores, competidores y con instituciones públicas y privadas de apoyo. El efecto conjunto de esas variables es lo que define la capacidad que ellas poseen de desarrollar estrategias competitivas. Los resultados permitirán concluir que el agrupamiento de productores de artefactos de desechos de madera es lo que está más articulado en relación con el conjunto de factores de éxito de un aglomerado, seguido por los aglomerados de productos en telares y hierros, que se presentan indiferentes entre sí.

  19. Description of CRIB, the GIPSY retrieval mechanism, and the interface to the General Electric MARK III Service : CRIB, the mineral resources data bank of the U.S. Geological Survey--guide for public users, 1977

    Science.gov (United States)

    Calkins, James Alfred; Keefer, Eleanor K.; Ofsharick, Regina A.; Mason, George T.; Tracy, Patricia; Atkins, Mary

    1978-01-01

    The U.S. Geological Survey's Computerized Resources Information Bank (CRIB) is being made available for public use through the computer facilities of the University of Oklahoma and the General Electric Company, U.S.A. The use of General Electric's worldwide information-services network provides access to the CRIB file to a worldwide clientele. This manual, which consists of two chapters, is intended as a guide to users who wish to interrogate the file. Chapter A contains a description of the CRIB file, information on the use of the GIPSY retrieval system, and a description of the General Electric MARK III Service. Chapter B contains a description of the individual data items in the CRIB record as well as code lists. CRIB consists of a set of variable-length records on the metallic and nonmetallic mineral resources of the United States and other countries. At present, 31,645 records in the master file are being made available. The record contains information on mineral deposits and mineral commodities. Some topics covered are: deposit name, location, commodity information, description of deposit, geology, production, reserves, potential resources, and references. The data are processed by the GIPSY program, which maintains the data file and builds, updates, searches, and prints the records using simple yet versatile command statements. Searching and selecting records is accomplished by specifying the presence, absence, or content of any element of information in the record; these specifications can be logically linked to prepare sophisticated search strategies. Output is available in the form of the complete record, a listing of selected parts of the record, or fixed-field tabulations. The General Electric MARK III Service is a computerized information services network operating internationally by land lines, satellites, and undersea cables. The service is available by local telephone to 500 cities in North America, Western Europe, Australia, Southeast Asia, Japan

  20. Antithrombin III for critically ill patients

    DEFF Research Database (Denmark)

    Allingstrup, Mikkel; Wetterslev, Jørn; Ravn, Frederikke B

    2016-01-01

    Background: Critical illness is associated with uncontrolled inflammation and vascular damage which can result in multiple organ failure and death. Antithrombin III (AT III) is an anticoagulant with anti-inflammatory properties but the efficacy and any harmful effects of AT III supplementation...... in critically ill patients are unknown. This review was published in 2008 and updated in 2015.  Objectives: To examine: 1. The effect of AT III on mortality in critically ill participants. 2. The benefits and harms of AT III. We investigated complications specific and not specific to the trial intervention......, bleeding events, the effect on sepsis and disseminated intravascular coagulation (DIC) and the length of stay in the intensive care unit (ICU) and in hospital in general.  Search methods: We searched the following databases from inception to 27 August 2015: Cochrane Central Register of Controlled Trials...

  1. The application of seasonal latent variable in forecasting electricity demand as an alternative method

    International Nuclear Information System (INIS)

    Sumer, Kutluk Kagan; Goktas, Ozlem; Hepsag, Aycan

    2009-01-01

    In this study, we used ARIMA, seasonal ARIMA (SARIMA) and alternatively the regression model with seasonal latent variable in forecasting electricity demand by using data that belongs to 'Kayseri and Vicinity Electricity Joint-Stock Company' over the 1997:1-2005:12 periods. This study tries to examine the advantages of forecasting with ARIMA, SARIMA methods and with the model has seasonal latent variable to each other. The results support that ARIMA and SARIMA models are unsuccessful in forecasting electricity demand. The regression model with seasonal latent variable used in this study gives more successful results than ARIMA and SARIMA models because also this model can consider seasonal fluctuations and structural breaks

  2. Solvent extraction of anionic chelate complexes of lanthanum(III), europium(III), lutetium(III), scandium(III), and indium(III) with 2-thenoyltrifluoroacetone as ion-pairs with tetrabutylammonium ions

    International Nuclear Information System (INIS)

    Noro, Junji; Sekine, Tatsuya.

    1992-01-01

    The solvent extraction of lanthanum(III), europium(III), lutetium(III), scandium(III), and indium(III) in 0.1 mol dm -3 sodium nitrate solutions with 2-thenoyltrifluoroacetone (Htta) in the absence and presence of tetrabutylammonium ions (tba + ) into carbon tetrachloride was measured. The extraction of lanthanum(III), europium(III), and lutetium(III) was greatly enhanced by the addition of tba + ; this could be explained in terms of the extraction of a ternary complex, M(tta) 4 - tba + . However, the extractions of scandium(III) and indium(III) were nearly the same when tba + was added. The data were treated on the basis of the formation equilibrium of the ternary complex from the neutral chelate, M(tta) 3 , with the extracted ion-pairs of the reagents, tta - tba + , in the organic phase. It was concluded that the degree of association of M(tta) 3 with the ion-pair, tta - tba + , is greater in the order La(tta) 3 ≅ Eu(tta) 3 > Lu(tta) 3 , or that the stability of the ternary complex in the organic phase is higher in the order La(tta) 4 - tba + ≅ Eu(tta) 4 - tba + > Lu(tta) 4 - tba + . This is similar to those of adduct metal chelates of Htta with tributylphosphate (TBP) in synergistic extraction systems. (author)

  3. Control system and method for a hybrid electric vehicle

    Science.gov (United States)

    Tamor, Michael Alan

    2001-03-06

    Several control methods are presented for application in a hybrid electric vehicle powertrain including in various embodiments an engine, a motor/generator, a transmission coupled at an input thereof to receive torque from the engine and the motor generator coupled to augment torque provided by the engine, an energy storage device coupled to receive energy from and provide energy to the motor/generator, an engine controller (EEC) coupled to control the engine, a transmission controller (TCM) coupled to control the transmission and a vehicle system controller (VSC) adapted to control the powertrain.

  4. A real-time insulation detection method for battery packs used in electric vehicles

    Science.gov (United States)

    Tian, Jiaqiang; Wang, Yujie; Yang, Duo; Zhang, Xu; Chen, Zonghai

    2018-05-01

    Due to the energy crisis and environmental pollution, electric vehicles have become more and more popular. Compared to traditional fuel vehicles, the electric vehicles are integrated with more high-voltage components, which have potential security risks of insulation. The insulation resistance between the chassis and the direct current bus of the battery pack is easily affected by factors such as temperature, humidity and vibration. In order to ensure the safe and reliable operation of the electric vehicles, it is necessary to detect the insulation resistance of the battery pack. This paper proposes an insulation detection scheme based on low-frequency signal injection method. Considering the insulation detector which can be easily affected by noises, the algorithm based on Kalman filter is proposed. Moreover, the battery pack is always in the states of charging and discharging during driving, which will lead to frequent changes in the voltage of the battery pack and affect the estimation accuracy of insulation detector. Therefore the recursive least squares algorithm is adopted to solve the problem that the detection results of insulation detector mutate with the voltage of the battery pack. The performance of the proposed method is verified by dynamic and static experiments.

  5. La(III) sorption studies on poly(dibenzo-18-crown-6) for the sequential separation of La(III), Th(IV) and U(VI) in L-arginine

    International Nuclear Information System (INIS)

    Sabale, Sandip; Nikam, Gurunath; Mohite, B.S.

    2010-01-01

    Poly(dibenzo-18-crown-6) is used as a stationary phase to study the sorption behavior of La(III) in L-arginine medium. The quantitative adsorption of La(III) was found at 1 x 10 -4 to 1 x 10 -6 M L-arginine. 1.0-8.0 M HCl, 0.5-8.0 M HBr and HClO 4 were found to be an efficient eluents for La(III). The capacity of crown polymer for La(III) was found to be 1.37±0.01 mmol/g. The tolerance limit of various cations and anions for La(III) was determined. La(III) was quantitatively separated from other metal ions in binary as well as multicomponent mixtures. The study was extended to sequential separation of La(III), U(VI) and Th(IV). The good separation yields were obtained and have good reproducibility (±2%). The method incorporates the determination of La(III) in real sample. The method is simple, rapid and selective. (author)

  6. Fire safety requirements for electrical cables towards nuclear reactor safety

    International Nuclear Information System (INIS)

    Raju, M.R.

    2002-01-01

    Full text: Electrical power supply forms a very important part of any nuclear reactor. Power supplies have been categorized in to class I, II, III and IV from reliability point. The safety related equipment are provided with highly reliable power supply to achieve the safety of very high order. Vast network of cables in a nuclear reactor are grouped and segregated to ensure availability of power to at least one group under all anticipated occurrences. Since fire can result in failures leading to unavailability of power caused by common cause, both passive and active fire protection methods are adopted in addition to fire detection system. The paper describes the requirement for passive fire protection to electrical cables viz. fire barrier and fire breaks. The paper gives an account of the tests required to standardize the products. Fire safety implementation for cables in research reactors is described

  7. PARDISEKO III

    International Nuclear Information System (INIS)

    Jordan, H.; Sack, C.

    1975-05-01

    This report gives a detailed description of the latest version of the PARDISEKO code, PARDISEKO III, with particular emphasis on the numerical and programming methods employed. The physical model and its relation to nuclear safety as well as a description and the results of confirming experiments are treated in detail in the Karlsruhe Nuclear Research Centre report KFK-1989. (orig.) [de

  8. A control system for and a method of controlling a superconductive rotating electrical machine

    DEFF Research Database (Denmark)

    2014-01-01

    This invention relates to a method of controlling and a control system (100) for a superconductive rotating electric machine (200) comprising at least one superconductive winding (102; 103), where the control system (100) is adapted to control a power unit (101) supplying during use the at least...... or more actual values (110, 111)of one or more parameters for a given superconductive winding (102; 103), each parameter representing a physical condition of the given superconductive winding (102; 103), and to dynamically derive one or more electrical current values to be maintained in the given...... superconductive winding (102; 103) by the power unit (101) where the one or more electrical current values is/are derived taking into account the received one or more actual values (110, 111). In this way,greater flexibility and more precise control of the performance of the superconducting rotating electrical...

  9. Arts and Crafts Classes in Years I–III, Based on Methods Featuring Pupils’ Practical Activities

    OpenAIRE

    Piwowarska, Ewa

    2016-01-01

    The issue to be analysed here concerns teachers’ planning of arts and crafts classes in Years I–III, with specific reference to methods featuring pupils’ practical activities. A theoretical part briefly presents the concepts involved in teaching a subject that was initially defined as drawing, then as arts and crafts education, and finally as arts and crafts classes. It points out the factors that influence the process of stimulating pupils’ artistic activities. The technique used in the cour...

  10. The electrical resistivity method in cased boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Schenkel, C.J.

    1991-05-01

    The use of downhole current sources in resistivity mapping can greatly enhance the detection and delineation of subsurface features. The purpose of this work is to examine the resistivity method for current sources in wells cased with steel. The resistivity method in cased boreholes with downhole current sources is investigated using the integral equation (IE) technique. The casing and other bodies are characterized as conductivity inhomogeneities in a half-space. For sources located along the casing axis, an axially symmetric Green's function is used to formulate the surface potential and electric field (E-field) volume integral equations. The situations involving off-axis current sources and three-dimensional (3-D) bodies is formulated using the surface potential IE method. The solution of the 3-D Green's function is presented in cylindrical and Cartesian coordinate systems. The methods of moments is used to solve the Fredholm integral equation of the second kind for the response due to the casing and other bodies. The numerical analysis revealed that the current in the casing can be approximated by its vertical component except near the source and the axial symmetric approximation of the casing is valid even for the 3-D problem. The E-field volume IE method is an effective and efficient technique to simulate the response of the casing in a half-space, whereas the surface potential approach is computationally better when multiple bodies are involved. Analyzing several configurations of the current source indicated that the casing response is influenced by four characteristic factors: conduction length, current source depth,casing depth, and casing length. 85 refs., 133 figs., 11 tabs.

  11. Effect of metal ion Fe(III on the performance of chlorophyll as photosensitizers on dye sensitized solar cell

    Directory of Open Access Journals (Sweden)

    Harsasi Setyawati

    Full Text Available The energy crisis is a major problem facing the world today and will need a renewable energy source that is environmentally friendly; one of these is the dye sensitized solar cell (DSSC. DSSC is photochemical electric cell that can convert solar energy into electrical energy. This research aims to study the characteristics of chlorophyll compounds with the addition of metal ions Fe(III and to determine the effect of Fe(III on the performance of chlorophyll as a photosensitizer in the DSSC. The formation of complex compounds of Fe(III-chlorophyll is shown by the phenomenon of metal ligand charge transfer (MLCT at a wavelength of 263.00 nm and absorption transition d-d at 745.00 nm. Fourier transform infrared characterization of the binding of Fe-O complex compounds appears at 486.06 cm−1. The complex compound of Fe(III-chlorophyll has a magnetic moment value of 9.62 Bohr Magneton (BM. The existence of ion Fe(III in chlorophyll can improve the performance of chlorophyll as a dye sensitizer with a maximum current of 4.00 mA/cm2, maximum voltage of 0.18 volts and efficiency values of 1.35%. Keywords: Fe(III-chlorophyll, Dye sensitized solar cell, Metal ligand charge transfer, Photosensitizer

  12. An iterative method for accelerated degradation testing data of smart electricity meter

    Science.gov (United States)

    Wang, Xiaoming; Xie, Jinzhe

    2017-01-01

    In order to evaluate the performance of smart electricity meter (SEM), we must spend a lot of time censoring its status. For example, if we assess to the meter stability of the SEM which needs several years at least according to the standards. So accelerated degradation testing (ADT) is a useful method to assess the performance of the SEM. As we known, the Wiener process is a prevalent method to interpret the performance degradation. This paper proposes an iterative method for ADT data of SEM. The simulation study verifies the application and superiority of the proposed model than other ADT methods.

  13. An extended NSGA-III for solution multi-objective hydro-thermal-wind scheduling considering wind power cost

    International Nuclear Information System (INIS)

    Yuan, Xiaohui; Tian, Hao; Yuan, Yanbin; Huang, Yuehua; Ikram, Rana M.

    2015-01-01

    Highlights: • Multi-objective hydro-thermal-wind scheduling model (MO-HTWS) is establish. • The extra cost in MO-HTWS problem caused by wind uncertainty is considered. • An extended NSGA-III is proposed to solve MO-HTWS problem. • Constraint handling strategies are presented to modify infeasible solutions. • The feasibility and effectiveness of the proposed method is verified by example. - Abstract: Due to the characteristics of clean and renewable, wind power is significant to economic and environmental operation of electric power system so that it attracts more and more attention from researchers. This paper integrates wind power with hydrothermal scheduling to establish multi-objective economic emission hydro-thermal-wind scheduling problem (MO-HTWS) model with considering wind uncertain cost. To solve MO-HTWS problem with various complicated constraints, this paper extends NSGA-III by introducing the dominance relationship criterion based on constraint violation to select new generation. Moreover, the constraint handling strategy which repairs the infeasible solutions by modifying the decision variables in feasible zone according to the violation amount is proposed. Finally, a daily scheduling example of hydro-thermal-wind system is used to test the ability of NSGA-III for solving MO-HTWS problem. It is concluded from the superior quality and good distribution of the Pareto optimal solutions that, NSGA-III can offer an efficient alternative for optimizing MO-HTWS problem

  14. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  15. Dissociation kinetics of Fe(III)- and Al(III)-natural organic matter complexes at pH 6.0 and 8.0 and 25 °C

    Science.gov (United States)

    Jones, Adele M.; Pham, A. Ninh; Collins, Richard N.; Waite, T. David

    2009-05-01

    The rate at which iron- and aluminium-natural organic matter (NOM) complexes dissociate plays a critical role in the transport of these elements given the readiness with which they hydrolyse and precipitate. Despite this, there have only been a few reliable studies on the dissociation kinetics of these complexes suggesting half-times of some hours for the dissociation of Fe(III) and Al(III) from a strongly binding component of NOM. First-order dissociation rate constants are re-evaluated here at pH 6.0 and 8.0 and 25 °C using both cation exchange resin and competing ligand methods for Fe(III) and a cation exchange resin method only for Al(III) complexes. Both methods provide similar results at a particular pH with a two-ligand model accounting satisfactorily for the dissociation kinetics results obtained. For Fe(III), half-times on the order of 6-7 h were obtained for dissociation of the strong component and 4-5 min for dissociation of the weak component. For aluminium, the half-times were on the order of 1.5 h and 1-2 min for the strong and weak components, respectively. Overall, Fe(III) complexes with NOM are more stable than analogous complexes with Al(III), implying Fe(III) may be transported further from its source upon dilution and dispersion.

  16. Sparkle/PM3 for the modeling of europium(III), gadolinium(III), and terbium(III) complexes

    International Nuclear Information System (INIS)

    Freire, Ricardo O.; Rocha, Gerd B.; Simas, Alfredo M.

    2009-01-01

    The Sparkle/PM3 model is extended to europium(III), gadolinium(III), and terbium(III) complexes. The validation procedure was carried out using only high quality crystallographic structures, for a total of ninety-six Eu(III) complexes, seventy Gd(III) complexes, and forty-two Tb(III) complexes. The Sparkle/PM3 unsigned mean error, for all interatomic distances between the trivalent lanthanide ion and the ligand atoms of the first sphere of coordination, is: 0.080 A for Eu(III); 0.063 A for Gd(III); and 0.070 A for Tb(III). These figures are similar to the Sparkle/AM1 ones of 0.082 A, 0.061 A, and 0.068 A respectively, indicating they are all comparable parameterizations. Moreover, their accuracy is similar to what can be obtained by present-day ab initio effective core potential full geometry optimization calculations on such lanthanide complexes. Finally, we report a preliminary attempt to show that Sparkle/PM3 geometry predictions are reliable. For one of the Eu(III) complexes, BAFZEO, we created hundreds of different input geometries by randomly varying the distances and angles of the ligands to the central Eu(III) ion, which were all subsequently fully optimized. A significant trend was unveiled, indicating that more accurate local minima geometries cluster at lower total energies, thus reinforcing the validity of sparkle model calculations. (author)

  17. Concepts and methods in neuromodulation and functional electrical stimulation: an introduction.

    Science.gov (United States)

    Holsheimer, J

    1998-04-01

    This article introduces two clinical fields in which stimulation is applied to the nervous system: neuromodulation and functional electrical stimulation. The concepts underlying these fields and their main clinical applications, as well as the methods and techniques used in each field, are described. Concepts and techniques common in one field that might be beneficial to the other are discussed. 1998 Blackwell Science, Inc.

  18. Method and device for current driven electric energy conversion

    DEFF Research Database (Denmark)

    2012-01-01

    Device comprising an electric power converter circuit for converting electric energy. The converter circuit comprises a switch arrangement with two or more controllable electric switches connected in a switching configuration and controlled so as to provide a current drive of electric energy from...... configurations such as half bridge buck, full bridge buck, half bridge boost, or full bridge boost. A current driven conversion is advantageous for high efficient energy conversion from current sources such as solar cells or where a voltage source is connected through long cables, e.g. powerline cables for long...... an associated electric source connected to a set of input terminals. This is obtained by the two or more electric swiches being connected and controlled to short-circuit the input terminals during a part of a switching period. Further, a low pass filter with a capacitor and an inductor are provided to low pass...

  19. Analysis of the electrical disturbances in CERN power distribution network with pattern mining methods

    CERN Document Server

    Abramenko, Oleksii

    2017-01-01

    The current research focuses on the perturbations within the electrical network of the LHC and its subsystems by analyzing measurements collected from oscilloscopes installed across different CERN sites, and alarms by electrical equipments. We analyze amplitude and duration of the glitches and, together with other relevant variables, correlate them with beam stopping events. The work also tries to identify assets affected by such perturbations using data mining and, in particular, frequent pattern mining methods. On the practical side we summarize results of our work by putting forward a prototype of a software tool enabling online monitoring of the alarms coming from the electrical network and facilitating glitch detection and analysis by a technical operator.

  20. Method of Relative Magnitudes for Calculating Magnetic Fluxes in Electrical Machine

    Directory of Open Access Journals (Sweden)

    Oleg A.

    2018-03-01

    Full Text Available Introduction: The article presents the study results of the model of an asynchronous electric motor carried out by the author within the framework of the Priorities Research Program “Research and development in the priority areas of development of Russia’s scientific and technical complex for 2014–2020”. Materials and Methods: A model of an idealized asynchronous machine (with sinusoidal distribution of magnetic induction in air gap is used in vector control systems. It is impossible to create windings for this machine. The basis of the new calculation approach was the Conductivity of Teeth Contours Method, developed at the Electrical Machines Chair of the Moscow Power Engineering Institute (MPEI. Unlike this method, the author used not absolute values, but relative magnitudes of magnetic fluxes. This solution fundamentally improved the method’s capabilities. The relative magnitudes of the magnetic fluxes of the teeth contours do not required the additional consideration for exact structure of magnetic field of tooth and adjacent slots. These structures are identical for all the teeth of the machine and differ only in magnitude. The purpose of the calculations was not traditional harmonic analysis of magnetic induction distribution in air gap of machine, but a refinement of the equations of electric machine model. The vector control researchers used only the cos(θ function as a value of mutual magnetic coupling coefficient between the windings. Results: The author has developed a way to take into account the design of the windings of a real machine by using imaginary measuring winding with the same winding design as a real phase winding. The imaginary winding can be placed in the position of any machine windings. The calculation of the relative magnetic fluxes of this winding helped to estimate the real values of the magnetic coupling coefficients between the windings, and find the correction functions for the model of an idealized

  1. Research progress of III-V laser bonding to Si

    Science.gov (United States)

    Bo, Ren; Yan, Hou; Yanan, Liang

    2016-12-01

    The vigorous development of silicon photonics makes a silicon-based light source essential for optoelectronics' integration. Bonding of III-V/Si hybrid laser has developed rapidly in the last ten years. In the tireless efforts of researchers, we are privileged to see these bonding methods, such as direct bonding, medium adhesive bonding and low temperature eutectic bonding. They have been developed and applied to the research and fabrication of III-V/Si hybrid lasers. Some research groups have made remarkable progress. Tanabe Katsuaki of Tokyo University successfully implemented a silicon-based InAs/GaAs quantum dot laser with direct bonding method in 2012. They have bonded the InAs/GaAs quantum dot laser to the silicon substrate and the silicon ridge waveguide, respectively. The threshold current of the device is as low as 200 A/cm2. Stevan Stanković and Sui Shaoshuai successfully produced a variety of hybrid III-V/Si laser with the method of BCB bonding, respectively. BCB has high light transmittance and it can provide high bonding strength. Researchers of Tokyo University and Peking University have realized III-V/Si hybrid lasers with metal bonding method. We describe the progress in the fabrication of III-V/Si hybrid lasers with bonding methods by various research groups in recent years. The advantages and disadvantages of these methods are presented. We also introduce the progress of the growth of III-V epitaxial layer on silicon substrate, which is also a promising method to realize silicon-based light source. I hope that readers can have a general understanding of this field from this article and we can attract more researchers to focus on the study in this field.

  2. Application of Learning Methods to Local Electric Field Distributions in Defected Dielectric Materials

    Science.gov (United States)

    Ferris, Kim; Jones, Dumont

    2014-03-01

    Local electric fields reflect the structural and dielectric fluctuations in a semiconductor, and affect the material performance both for electron transport and carrier lifetime properties. In this paper, we use the LOCALF methodology with periodic boundary conditions to examine the local electric field distributions and its perturbations for II-VI (CdTe, Cd(1-x)Zn(x)Te) semiconductors, containing Te inclusions and small fluctuations in the local dielectric susceptibility. With inclusion of the induced-field term, the electric field distribution shows enhancements and diminishments compared to the macroscopic applied field, reflecting the microstructure characteristics of the dielectric. Learning methods are applied to these distributions to assess the spatial extent of the perturbation, and determine an electric field defined defect size as compared to its physical dimension. Critical concentrations of defects are assessed in terms of defect formation energies. This work was supported by the US Department of Homeland Security, Domestic Nuclear Detection Office, under competitively awarded contract/IAA HSHQDC-08-X-00872-e. This support does not constitute an express or implied endorsement on the part of the Gov't.

  3. Electrical and dielectric investigation of intercalated polypyrrole montmorillonite nanocomposite prepared by spontaneous polymerization of pyrrole into Fe(III)-montmorillonite

    Energy Technology Data Exchange (ETDEWEB)

    Zidi, Rabii, E-mail: rabiizidi@gmail.com [Physical Chemistry Laboratory for Mineral Materials and their Applications, National Center for Research in Materials Sciences (CNRSM), B.P.73, 8020 Soliman (Tunisia); Bekri-Abbes, Imene; Sdiri, Nasr [Physical Chemistry Laboratory for Mineral Materials and their Applications, National Center for Research in Materials Sciences (CNRSM), B.P.73, 8020 Soliman (Tunisia); Vimalanandan, Ashokanand; Rohwerder, Michael [Max-Planck-Institut für Eisenforschung GmbH, Düsseldorf (Germany); Srasra, Ezzeddine [Physical Chemistry Laboratory for Mineral Materials and their Applications, National Center for Research in Materials Sciences (CNRSM), B.P.73, 8020 Soliman (Tunisia)

    2016-10-15

    Highlights: • We have prepared and characterized a Fe-MMT/PPy nanocomposites. • Investigate electrical conductivity and dielectric properties of the nanocomposite. • Investigate the temperature and frequency dependencies of alternating current conductivity of nanocomposites. - Abstract: Pyrrole was introduced into Fe(III)-exchanged montmorillonite to spontaneously polymerize within the interlayer resulting in the formation of intercalated polypyrrole-montmorillonite nanocomposite. The molar proportion of pyrrole to interlayer Fe{sup 3+} (R) has been varied from 0.5 to 5. The nanocomposite has been characterized by X-ray diffraction, Scanning Electronic Microscope, FTIR spectroscopy and impedance spectroscopy. It has been shown that intercalated polypyrrole montmorillonite nanocomposite was obtained. The results showed that the dc conductivity and dielectric properties of polypyrrole depend on R. The alternating current (ac) conductivity of the polymer obeys the power law, i.e., σ{sub ac}(ω) = Aω{sup s}. The alternating conductivity of nanocomposite was controlled by the correlated barrier hopping model. The activation energy for alternating current mechanism decreases with increasing frequency which confirms the hopping conduction to the dominant mechanism as compared with the dc activation energy. The dielectric relaxation mechanism was explained on the basis of complex dielectric modulus.

  4. Electrical Resistance Based Damage Modeling of Multifunctional Carbon Fiber Reinforced Polymer Matrix Composites

    Science.gov (United States)

    Hart, Robert James

    In the current thesis, the 4-probe electrical resistance of carbon fiber-reinforced polymer (CFRP) composites is utilized as a metric for sensing low-velocity impact damage. A robust method has been developed for recovering the directionally dependent electrical resistivities using an experimental line-type 4-probe resistance method. Next, the concept of effective conducting thickness was uniquely applied in the development of a brand new point-type 4-probe method for applications with electrically anisotropic materials. An extensive experimental study was completed to characterize the 4-probe electrical resistance of CFRP specimens using both the traditional line-type and new point-type methods. Leveraging the concept of effective conducting thickness, a novel method was developed for building 4-probe electrical finite element (FE) models in COMSOL. The electrical models were validated against experimental resistance measurements and the FE models demonstrated predictive capabilities when applied to CFRP specimens with varying thickness and layup. These new models demonstrated a significant improvement in accuracy compared to previous literature and could provide a framework for future advancements in FE modeling of electrically anisotropic materials. FE models were then developed in ABAQUS for evaluating the influence of prescribed localized damage on the 4-probe resistance. Experimental data was compiled on the impact response of various CFRP laminates, and was used in the development of quasi- static FE models for predicting presence of impact-induced delamination. The simulation-based delamination predictions were then integrated into the electrical FE models for the purpose of studying the influence of realistic damage patterns on electrical resistance. When the size of the delamination damage was moderate compared to the electrode spacing, the electrical resistance increased by less than 1% due to the delamination damage. However, for a specimen with large

  5. Parameters for Fabricating Nano-Au Colloids through the Electric Spark Discharge Method with Micro-Electrical Discharge Machining.

    Science.gov (United States)

    Tseng, Kuo-Hsiung; Chung, Meng-Yun; Chang, Chaur-Yang

    2017-06-02

    In this study, the Electric Spark Discharge Method (ESDM) was employed with micro-electrical discharge machining (m-EDM) to create an electric arc that melted two electrodes in deionized water (DW) and fabricated nano-Au colloids through pulse discharges with a controlled on-off duration (T ON -T OFF ) and a total fabrication time of 1 min. A total of six on-off settings were tested under normal experimental conditions and without the addition of any chemical substances. Ultraviolet-visible spectroscopy (UV-Vis), Zetasizer Nano measurements, and scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analyses suggested that the nano-Au colloid fabricated at 10-10 µs (10 µs on, 10 µs off) had higher concentration and suspension stability than products made at other T ON -T OFF settings. The surface plasmon resonance (SPR) of the colloid was 549 nm on the first day of fabrication and stabilized at 532 nm on the third day. As the T ON -T OFF period increased, the absorbance (i.e., concentration) of all nano-Au colloids decreased. Absorbance was highest at 10-10 µs. The SPR peaks stabilized at 532 nm across all T ON -T OFF periods. The Zeta potential at 10-10 µs was -36.6 mV, indicating that no nano-Au agglomeration occurred and that the particles had high suspension stability.

  6. The method of the correlation and dispersion defining of the total power components in the electric transport devices

    Directory of Open Access Journals (Sweden)

    A. V. Nikitenko

    2013-04-01

    Full Text Available Purpose. Development and theoretical ground of the analytical method for the calculation of the active, reactive and total powers in the electric traction devices, taking into consideration the non-stationary character of the stochastic processes change of the voltage and current in the elements of these systems. Methodology. The mathematical methods of the random processes theory and the “discrete electrical engineering” methods are used for solving the main problem of this paper. Findings. The Method of the Correlation and Dispersion is developed for definition of the active power, the reactive power by Fryse and the total power of the devices in the elements of the electric traction system of the main-line railways. The method is based on the well-known concepts of auto- and inter-correlation functions of the random processes which govern the feeder voltages and the currents in the traction power supply subsystem as well as the currents and voltages of the electric rolling stock. The method developed in this paper allows estimating the powers of both stationary and non-stationary processes. This method can be used for the analysis of both the traction mode and the regenerative braking mode of the electric rolling stock. The total power components were calculated for the one of the feeder areas of the Prydniprovsk railway using this method. The results show the significant flow of the reactive power in the traction power supply system. This fact is also confirmed by the high values of the reactive power coefficient. Originality. Scientific novelty of the research is consisted in the following. Firstly, for defining the active and reactive powers in elements of the traction power supply system the new method (the Method of Correlation and Dispersion is created and grounded. This method is different from other existing methods because it takes into consideration the varying non-stationary character of the chance processes of the feeder and

  7. Synthesis of Er(III)/Yb(III)-doped BiF3 upconversion nanoparticles for use in optical thermometry.

    Science.gov (United States)

    Du, Peng; Yu, Jae Su

    2018-03-23

    The authors describe an ethylene glycol assisted precipitation method for synthesis of Er(III)/Yb(III)-doped BiF 3 nanoparticles (NPs) at room temperature. Under 980-nm light irradiation, the NPs emit upconversion (UC) emission of Er(III) ions as a result of a two-photon absorption process. The temperature-dependent green emissions (peaking at 525 and 545 nm) are used to establish an unambiguous relationship between the ratio of fluorescence intensities and temperature. The NPs have a maximum sensitivity of 6.5 × 10 -3  K -1 at 619 K and can be applied over the 291-691 K temperature range. The results indicate that these NPs are a promising candidate for optical thermometry. Graphical abstract Schematic of the room-temperature preparation of Er(III)/Yb(III)-doped BiF 3 nanoparticles with strongly temperature-dependent upconversion emission.

  8. Simple method for identifying doubly ionized uranium (U III) produced in a hollow-cathode discharge

    International Nuclear Information System (INIS)

    Piyakis, K.N.; Gagne, J.M.

    1988-01-01

    We have studied by emission spectroscopy the spectral properties of doubly ionized uranium, produced in a vapor generator of hollow-cathode design, as a function of the nature of a pure fill gas (helium, neon, argon, krypton, xenon) and its pressure. The spectral intensity is found to increase with increasing ionization potential of the discharge buffer gas, except in the case of helium. Based on our preliminary results, a simple and practical method for the positive identification of the complex U III spectrum is suggested

  9. Review of laser-induced fluorescence methods for measuring rf- and microwave electric fields in discharges

    International Nuclear Information System (INIS)

    Gavrilenko, V.; Oks, E.

    1994-01-01

    Development of methods for measuring rf- or μ-wave electric fields E(t) = E 0 cosωt in discharge plasmas is of a great practical importance. First, these are fields used for producing rf- or μ-wave discharges. Second, the fields E(t) may represent electromagnetic waves penetrating into a plasma from the outside. This paper reviews methods for diagnostics of the fields E(t) in low temperature plasmas based on Laser-Induced Fluorescence (LIF). Compared to emission (passive) methods, LIF-methods have a higher sensitivity as well as higher spatial and temporal resolutions. Underlying physical effects may be highlighted by an example of LIF of hydrogen atoms in a plasma. After a presentation of the underlying physical principles, the review focuses on key experiments where these principles were implemented for measurements of rf- and μ-wave electric fields in various discharges

  10. Uranium (III)-Plutonium (III) co-precipitation in molten chloride

    Science.gov (United States)

    Vigier, Jean-François; Laplace, Annabelle; Renard, Catherine; Miguirditchian, Manuel; Abraham, Francis

    2018-02-01

    Co-management of the actinides in an integrated closed fuel cycle by a pyrochemical process is studied at the laboratory scale in France in the CEA-ATALANTE facility. In this context the co-precipitation of U(III) and Pu(III) by wet argon sparging in LiCl-CaCl2 (30-70 mol%) molten salt at 705 °C is studied. Pu(III) is prepared in situ in the molten salt by carbochlorination of PuO2 and U(III) is then introduced as UCl3 after chlorine purge by argon to avoid any oxidation of uranium up to U(VI) by Cl2. The oxide conversion yield through wet argon sparging is quantitative. However, the preferential oxidation of U(III) in comparison to Pu(III) is responsible for a successive conversion of the two actinides, giving a mixture of UO2 and PuO2 oxides. Surprisingly, the conversion of sole Pu(III) in the same conditions leads to a mixture of PuO2 and PuOCl, characteristic of a partial oxidation of Pu(III) to Pu(IV). This is in contrast with coconversion of U(III)-Pu(III) mixtures but in agreement with the conversion of Ce(III).

  11. Evaluation of the penetration depth of the shell welds by electrical methods

    International Nuclear Information System (INIS)

    Laille, Alain.

    1979-07-01

    The aim of the present work is the development of two electrical non-destructive methods (eddy currents and potentiometry) to estimate the penetration depth of electron bombardment welds. To illustrate the study and show its potential applications these methods are used on various materials (1 to 3 mm thick) and the results compared with the real welded depth evaluated after sectioning. Finally the potentiometric set-up is coupled to a data acquisition and processing system [fr

  12. Purification of chicken carbonic anhydrase isozyme-III (CA-III and its measurement in White Leghorn chickens

    Directory of Open Access Journals (Sweden)

    Nishita Toshiho

    2011-11-01

    Full Text Available Abstract Background The developmental profile of chicken carbonic anhydrase-III (CA-III blood levels has not been previously determined or reported. We isolated CA-III from chicken muscle and investigated age-related changes in the levels of CA-III in blood. Methods CA-III was purified from chicken muscle. The levels of CA-III in plasma and erythrocytes from 278 female chickens (aged 1-93 weeks and 68 male chickens (aged 3-59 weeks were determined by ELISA. Results The mean level of CA-III in female chicken erythrocytes (1 week old was 4.6 μg/g of Hb, and the CA-III level did not change until 16 weeks of age. The level then increased until 63 weeks of age (11.8 μg/g of Hb, decreased to 4.7 μg/g of Hb at 73 weeks of age, and increased again until 93 weeks of age (8.6 μg/g of Hb. The mean level of CA-III in erythrocytes from male chickens (3 weeks old was 2.4 μg/g of Hb, and this level remained steady until 59 weeks of age. The mean plasma level of CA-III in 1-week-old female chickens was 60 ng/mL, and this level was increased at 3 weeks of age (141 ng/mL and then remained steady until 80 weeks of age (122 ng/mL. The mean plasma level of CA-III in 3-week-old male chickens was 58 ng/mL, and this level remained steady until 59 weeks of age. Conclusion We observed both developmental changes and sex differences in CA-III concentrations in White Leghorn (WL chicken erythrocytes and plasma. Simple linear regression analysis showed a significant association between the erythrocyte CA-III level and egg-laying rate in WL-chickens 16-63 weeks of age (p

  13. VTT ENIGMA Calculations for FUMEX-III CRP

    International Nuclear Information System (INIS)

    Tulkki, Ville

    2013-01-01

    International Atomic Energy Agency IAEA has initiated a string of Coordinated Research Programmes (CRPs) to enhance co-operation between fuel modellers. One of these CRPs, FUMEX-III, was ongoing during 2008 - 2011 and has provided material and incentive for assessment of the fuel codes. This report presents the Finnish FUMEX-III simulations performed with the VTT-modified ENIGMA v5.9b. The work has been done as a part of SAFIR2010 (SAfety of FInnish Reactors 2010) project POKEVA (years 2008 to 2010) and SAFIR2014 project PALAMA (year 2011). VTT Technical Research Centre of Finland received ENIGMA v5.9b from Nuclear Electric plc of the UK in 1992. Internal development has been on-going since then. 'ENIGMA v5.9b with VTT modifications' (from now on, 'ENIGMA' for short) is a separate and different program from British Energy's ENIGMA 5.14 and UK National Nuclear Laboratory's ENIGMA-B. The FUMEX-III work has been performed in tandem of VTT's internal review work attempting to catalogue the changes done since 1992 and to assess the current state of the code. Several individual internal reports detail the changes made and the individual model assessments done during the years. (author)

  14. PLN's experience with the WASP-III model in generation expansion planning for the Java system

    International Nuclear Information System (INIS)

    Sudja, N.; Afiff, A.; Simarmata, B.

    1988-01-01

    The State Electric Power Corporation of Indonesia (PLN) was one of the first recipients of the WASP computer model, and since 1976 has been using the model (first the version WASP-II, and later the WASP-III version) for carrying out generation expansion planning studies for the country, and particularly, for the Java power system. This paper discusses PLN's experience with WASP-III and comments on some problems and constraints encountered, particularly: the time-fixed forced outage rate (FOR) assumed for generating units, simulation of the hydro system and computation time. The paper concludes with some suggestions about future enhancements to WASP-III. (author). 3 figs, 11 tabs

  15. Trends in heteroepitaxy of III-Vs on silicon for photonic and photovoltaic applications

    Science.gov (United States)

    Lourdudoss, Sebastian; Junesand, Carl; Kataria, Himanshu; Metaferia, Wondwosen; Omanakuttan, Giriprasanth; Sun, Yan-Ting; Wang, Zhechao; Olsson, Fredrik

    2017-02-01

    We present and compare the existing methods of heteroepitaxy of III-Vs on silicon and their trends. We focus on the epitaxial lateral overgrowth (ELOG) method as a means of achieving good quality III-Vs on silicon. Initially conducted primarily by near-equilibrium epitaxial methods such as liquid phase epitaxy and hydride vapour phase epitaxy, nowadays ELOG is being carried out even by non-equilibrium methods such as metal organic vapour phase epitaxy. In the ELOG method, the intermediate defective seed and the mask layers still exist between the laterally grown purer III-V layer and silicon. In a modified ELOG method called corrugated epitaxial lateral overgrowth (CELOG) method, it is possible to obtain direct interface between the III-V layer and silicon. In this presentation we exemplify some recent results obtained by these techniques. We assess the potentials of these methods along with the other existing methods for realizing truly monolithic photonic integration on silicon and III-V/Si heterojunction solar cells.

  16. The measurement of magnetic properties of electrical sheet steel - survey on methods and situation of standards

    CERN Document Server

    Sievert, J

    2000-01-01

    A brief review of the different requirements for magnetic measurement techniques for material research, modelling of material properties and grading of the electrical sheet steel for trade purposes is presented. In relation to the main application of laminated electrical steel, this paper deals with AC measurement techniques. Two standard methods, Epstein frame and Single Sheet Tester (SST), producing different results, are used in parallel. This dilemma was analysed in detail. The study leads to a possible solution of the problem, i.e. the possibility of converting the results of one of the two methods into the results of the other in order to satisfy the users of the Epstein method and, at the same time, to improve the acceptance of the more economical SST method.

  17. Method of recovering oil from alum shales. [heating by electric currents

    Energy Technology Data Exchange (ETDEWEB)

    Wennerstrom, K G

    1918-06-04

    A method of treating alum shale and other bituminous shales in order to extract oil et cetera, is characterized by bringing the shale to a temperature at which it melts, and at which the necessary amount of heat is transferred to the molten shale to be distilled. The patent claim is characterized by heating the shale by means of electric current. The patent has one additional claim.

  18. A reliable method for intracranial electrode implantation and chronic electrical stimulation in the mouse brain.

    Science.gov (United States)

    Jeffrey, Melanie; Lang, Min; Gane, Jonathan; Wu, Chiping; Burnham, W McIntyre; Zhang, Liang

    2013-08-06

    Electrical stimulation of brain structures has been widely used in rodent models for kindling or modeling deep brain stimulation used clinically. This requires surgical implantation of intracranial electrodes and subsequent chronic stimulation in individual animals for several weeks. Anchoring screws and dental acrylic have long been used to secure implanted intracranial electrodes in rats. However, such an approach is limited when carried out in mouse models as the thin mouse skull may not be strong enough to accommodate the anchoring screws. We describe here a screw-free, glue-based method for implanting bipolar stimulating electrodes in the mouse brain and validate this method in a mouse model of hippocampal electrical kindling. Male C57 black mice (initial ages of 6-8 months) were used in the present experiments. Bipolar electrodes were implanted bilaterally in the hippocampal CA3 area for electrical stimulation and electroencephalographic recordings. The electrodes were secured onto the skull via glue and dental acrylic but without anchoring screws. A daily stimulation protocol was used to induce electrographic discharges and motor seizures. The locations of implanted electrodes were verified by hippocampal electrographic activities and later histological assessments. Using the glue-based implantation method, we implanted bilateral bipolar electrodes in 25 mice. Electrographic discharges and motor seizures were successfully induced via hippocampal electrical kindling. Importantly, no animal encountered infection in the implanted area or a loss of implanted electrodes after 4-6 months of repetitive stimulation/recording. We suggest that the glue-based, screw-free method is reliable for chronic brain stimulation and high-quality electroencephalographic recordings in mice. The technical aspects described this study may help future studies in mouse models.

  19. Removal of stored particle background via the electric dipole method in the KATRIN main spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hilk, Daniel [Institut fuer Experimentelle Kernphysik, KIT, Karlsruhe (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The goal of the KArlsruhe TRItium Neutrino (KATRIN) experiment is to determine the effective mass of the electron anti neutrino by measuring the electron energy spectrum of tritium beta decay near the endpoint. The goal is to reach a sensitivity on the neutrino mass of 200 meV for which a low background level of 10{sup -2} counts per second is mandatory. Electrons from single radioactive decays of radon and tritium in the KATRIN main spectrometer with energies in the keV range can be magnetically stored for hours. While cooling down via ionization of residual gas molecules, they produce hundreds of secondary electrons, which can reach the detector and contribute to the background signals. In order to suppress this background component, several methods are investigated to remove stored electrons, such as the application of an electric dipole field and the application of magnetic pulses. This talk introduces the mechanism of background production due to stored electrons and their removal by the electric dipole method in the main spectrometer. In context of the spectrometer- and detector-commissioning phase in summer 2015, measurement results of the application of the electric dipole method are presented.

  20. Modeling of Electric Field Around 100 MVA 150/20 KV Power Transformator Using Charge Simulation Method

    OpenAIRE

    Rachman, Noviadi Arief; Risdiyanto, Agus; Ramdan, Ade

    2013-01-01

    Charge Simulation Method is one of the field theory that can be used as an approach to calculate the electromagnetic distribution on the electrical conductor. This paper discussed electric field modeling around power transformator by using Matlab to find the safety distance. The safe distance threshold of the electric field to human health refers to WHO and SNI was 5 kV/m. The specification of the power transformator was three phases, 150/20 kV, and 100 MVA. The basic concept is to change the...

  1. EDTA excess Zn(II) back-titration in the presence of 4-(2-pyridylazo)-resorcinol indicator and naphthol green β as inert dye for determining Cr(III) as Cr(III)/EDTA complex: Application of the method to a leather industry wastewater

    International Nuclear Information System (INIS)

    Venezia, M.; Alonzo, G.; Palmisano, L.

    2008-01-01

    The colour changes of 4-(2-pyridylazo)-resorcinol and naphthol green β as new screening metallochromic indicator in back-titration of EDTA excess with Zn(II) to determine Cr(III)/EDTA complex was investigated with the help of tristimulus colorimetry. Specific colour discrimination (SCD) and L*, a*, b* 1976 parameters were successfully applied to evaluate the quality of colour transition at the end-point in non-alkaline media and in the presence of Zn(II) and Ca(II) which resulted in non-interfering species at 1 x 10 -3 M and 2 x 10 -3 M, respectively. The above concentrations are comparable with those used for Cr(III). Validation of the fast and accurate reported method was performed by atomic absorption spectroscopy. Moreover, the method was applied for determining Cr as Cr(III) in a wastewater effluent deriving from a leather industry

  2. Comparison of three methods for the estimation of cross-shock electric potential using Cluster data

    Directory of Open Access Journals (Sweden)

    A. P. Dimmock

    2011-05-01

    Full Text Available Cluster four point measurements provide a comprehensive dataset for the separation of temporal and spatial variations, which is crucial for the calculation of the cross shock electrostatic potential using electric field measurements. While Cluster is probably the most suited among present and past spacecraft missions to provide such a separation at the terrestrial bow shock, it is far from ideal for a study of the cross shock potential, since only 2 components of the electric field are measured in the spacecraft spin plane. The present paper is devoted to the comparison of 3 different techniques that can be used to estimate the potential with this limitation. The first technique is the estimate taking only into account the projection of the measured components onto the shock normal. The second uses the ideal MHD condition E·B = 0 to estimate the third electric field component. The last method is based on the structure of the electric field in the Normal Incidence Frame (NIF for which only the potential component along the shock normal and the motional electric field exist. All 3 approaches are used to estimate the potential for a single crossing of the terrestrial bow shock that took place on the 31 March 2001. Surprisingly all three methods lead to the same order of magnitude for the cross shock potential. It is argued that the third method must lead to more reliable results. The effect of the shock normal inaccuracy is investigated for this particular shock crossing. The resulting electrostatic potential appears too high in comparison with the theoretical results for low Mach number shocks. This shows the variability of the potential, interpreted in the frame of the non-stationary shock model.

  3. Method for providing slip energy control in permanent magnet electrical machines

    Science.gov (United States)

    Hsu, John S.

    2006-11-14

    An electric machine (40) has a stator (43), a permanent magnet rotor (38) with permanent magnets (39) and a magnetic coupling uncluttered rotor (46) for inducing a slip energy current in secondary coils (47). A dc flux can be produced in the uncluttered rotor when the secondary coils are fed with dc currents. The magnetic coupling uncluttered rotor (46) has magnetic brushes (A, B, C, D) which couple flux in through the rotor (46) to the secondary coils (47c, 47d) without inducing a current in the rotor (46) and without coupling a stator rotational energy component to the secondary coils (47c, 47d). The machine can be operated as a motor or a generator in multi-phase or single-phase embodiments and is applicable to the hybrid electric vehicle. A method of providing a slip energy controller is also disclosed.

  4. Spectroelectrochemical insights into structural and redox properties of immobilized endonuclease III and its catalytically inactive mutant

    Science.gov (United States)

    Moe, Elin; Rollo, Filipe; Silveira, Célia M.; Sezer, Murat; Hildebrandt, Peter; Todorovic, Smilja

    2018-01-01

    Endonuclease III is a Fe-S containing bifunctional DNA glycosylase which is involved in the repair of oxidation damaged DNA. Here we employ surface enhanced IR spectroelectrochemistry and electrochemistry to study the enzyme from the highly radiation- and desiccation-resistant bacterium Deinococcus radiodurans (DrEndoIII2). The experiments are designed to shed more light onto specific parameters that are currently proposed to govern damage search and recognition by endonucleases III. We demonstrate that electrostatic interactions required for the redox activation of DrEndoIII2 may result in high electric fields that alter its structural and thermodynamic properties. Analysis of inactive DrEndoIII2 (K132A/D150A double mutant) interacting with undamaged DNA, and the active enzyme interacting with damaged DNA also indicate that the electron transfer is modulated by subtle differences in the protein-DNA complex.

  5. Electrical stunning of farmed Atlantic cod Gadus morhua L.: a comparison of an industrial and experimental method

    NARCIS (Netherlands)

    Digre, H.; Erikson, U.; Misimi, E.; Lambooij, E.; Vis, van de J.W.

    2010-01-01

    An industrial and experimental electrical method for stunning farmed Atlantic cod in air and seawater (SW), respectively, were compared. The impacts of sedation with AQUI-S™ and exercise to exhaustion before electrical stunning were also assessed to monitor the possible depletion of rested muscle

  6. Interaction mode between methylene blue-Sm(III) complex and ...

    African Journals Online (AJOL)

    Spectroscopic and viscosity methods were applied to investigate the interaction between methylene blue (MB)-Sm(III) complex and herring sperm DNA by using acridine orange as a spectral probe in Tris-HCl buffer (pH 7.40). By means of molar ratio method, the binding ratios between MB-Sm(III)and DNA were determined ...

  7. Nuclear qualified in-containment electrical connectors and method of connecting electrical conductors

    Science.gov (United States)

    Powell, J. G.

    1991-01-01

    A nuclear qualified in-containment electrical connection comprises an insulated, sheathed instrument lead having electrical conductors extending from one end thereof to provide two exposed lead wires, a watertight cable having electrical conducting wires therein and extending from one end of the cable to provide two lead wires therefrom, two butt splice connectors each connecting the ends of respective ones of the lead wires from the instrument lead and cable, a length of heat shrinkable plastic tubing positioned over each butt splice connector and an adjacent portion of a respective lead wire from the cable and heat shrunk into position, a length of heat shrinkable plastic tubing on the end portion of the instrument lead adjacent the lead wires therefrom and heat shrunk thereon and a length of outer heat shrinkable plastic tubing extending over the end portion of the instrument lead and the heat shrinkable tubing thereon and over the butt splice connectors and a portion of the cable adjacent the cable lead lines, the outer heat shrinkable tubing being heat shrunk into sealing position on the instrument lead and cable.

  8. Method for extracting relevant electrical parameters from graphene field-effect transistors using a physical model

    International Nuclear Information System (INIS)

    Boscá, A.; Pedrós, J.; Martínez, J.; Calle, F.

    2015-01-01

    Due to its intrinsic high mobility, graphene has proved to be a suitable material for high-speed electronics, where graphene field-effect transistor (GFET) has shown excellent properties. In this work, we present a method for extracting relevant electrical parameters from GFET devices using a simple electrical characterization and a model fitting. With experimental data from the device output characteristics, the method allows to calculate parameters such as the mobility, the contact resistance, and the fixed charge. Differentiated electron and hole mobilities and direct connection with intrinsic material properties are some of the key aspects of this method. Moreover, the method output values can be correlated with several issues during key fabrication steps such as the graphene growth and transfer, the lithographic steps, or the metalization processes, providing a flexible tool for quality control in GFET fabrication, as well as a valuable feedback for improving the material-growth process

  9. Method for extracting relevant electrical parameters from graphene field-effect transistors using a physical model

    Energy Technology Data Exchange (ETDEWEB)

    Boscá, A., E-mail: alberto.bosca@upm.es [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Dpto. de Ingeniería Electrónica, E.T.S.I. de Telecomunicación, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Pedrós, J. [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Campus de Excelencia Internacional, Campus Moncloa UCM-UPM, Madrid 28040 (Spain); Martínez, J. [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Dpto. de Ciencia de Materiales, E.T.S.I de Caminos, Canales y Puertos, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Calle, F. [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Dpto. de Ingeniería Electrónica, E.T.S.I. de Telecomunicación, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Campus de Excelencia Internacional, Campus Moncloa UCM-UPM, Madrid 28040 (Spain)

    2015-01-28

    Due to its intrinsic high mobility, graphene has proved to be a suitable material for high-speed electronics, where graphene field-effect transistor (GFET) has shown excellent properties. In this work, we present a method for extracting relevant electrical parameters from GFET devices using a simple electrical characterization and a model fitting. With experimental data from the device output characteristics, the method allows to calculate parameters such as the mobility, the contact resistance, and the fixed charge. Differentiated electron and hole mobilities and direct connection with intrinsic material properties are some of the key aspects of this method. Moreover, the method output values can be correlated with several issues during key fabrication steps such as the graphene growth and transfer, the lithographic steps, or the metalization processes, providing a flexible tool for quality control in GFET fabrication, as well as a valuable feedback for improving the material-growth process.

  10. Aquifer Characterization from Surface Geo-electrical Method, western coast of Maharashtra, India

    Science.gov (United States)

    DAS, A.; Maiti, D. S.

    2017-12-01

    Knowledge of aquifer parameters are necessary for managing groundwater amenity. These parameters are evaluated through pumping tests bring off from bore wells. But it is quite expensive as well as time consuming to carry out pumping tests at various sites and sometimes it is difficult to find bore hole at every required site. Therefore, an alternate method is put forward in which the aquifer parameters are evaluated from surface geophysical method. In this method, vertical electrical sounding (VES) with Schlumberger configuration were accomplished in 85 stations over Sindhudurg district. Sindhudurg district is located in the Konkan region of Maharashtra state, India. The district is located between north latitude 15°37' and 16° 40' and east longitude 73° 19' and 74° 13'. The area is having hard rock and acute groundwater problem. In this configuration, we have taken the maximum current electrode spacing of 200 m for every vertical electrical sounding (VES). Geo-electrical sounding data (true resistivity and thickness) is interpreted through resistivity inversion approach. The required parameters are achieved through resistivity inversion technique from which the aquifer variables (D-Z parameters, mean resistivity, hydraulic conductivity, transmissivity, and coefficient of anisotropy) are calculated by using some empirical formulae. Cross-correlation investigation has been done between these parameters, which eventually used to characterize the aquifer over the study area. At the end, the contour plot for these aquifer parameters has been raised which reveals the detailed distribution of aquifer parameters throughout the study area. From contour plot, high values of longitudinal conductance, hydraulic conductivity and transmissivity are demarcate over Kelus, Vengurle, Mochemar and Shiroda villages. This may be due to intrusion of saline water from Arabian sea. From contour trends, the aquifers are characterized from which the groundwater resources could be

  11. Estimating zonal electricity supply curves in transmission-constrained electricity markets

    International Nuclear Information System (INIS)

    Sahraei-Ardakani, Mostafa; Blumsack, Seth; Kleit, Andrew

    2015-01-01

    Many important electricity policy initiatives would directly affect the operation of electric power networks. This paper develops a method for estimating short-run zonal supply curves in transmission-constrained electricity markets that can be implemented quickly by policy analysts with training in statistical methods and with publicly available data. Our model enables analysis of distributional impacts of policies affecting operation of electric power grid. The method uses fuel prices and zonal electric loads to determine piecewise supply curves, identifying zonal electricity price and marginal fuel. We illustrate our methodology by estimating zonal impacts of Pennsylvania's Act 129, an energy efficiency and conservation policy. For most utilities in Pennsylvania, Act 129 would reduce the influence of natural gas on electricity price formation and increase the influence of coal. The total resulted savings would be around 267 million dollars, 82 percent of which would be enjoyed by the customers in Pennsylvania. We also analyze the impacts of imposing a $35/ton tax on carbon dioxide emissions. Our results show that the policy would increase the average prices in PJM by 47–89 percent under different fuel price scenarios in the short run, and would lead to short-run interfuel substitution between natural gas and coal. - Highlights: • We develop a method to estimate of zonal supply curves in electricity markets. • The model estimates zonal electricity prices and zonal fuel utilization. • The model implicitly captures the average impacts of transmission constraints. • Using the method, we project supply curves for the seventeen utility zones of PJM. • We use the estimated supply curves to study the impacts of Pennsylvania's Act 129 and a carbon tax of $35 per ton

  12. Analysis of the material's expenditure of electric contacts by means of the isotopic method

    International Nuclear Information System (INIS)

    Farkash, K.

    1979-01-01

    To investigate lifetime of the weak-current and heavy-current contacts different radioisotopic methods have been developed. Advantages of the radioisotopic methods as compared with other methods of testing consists of the fact that due to their sensitivity they permit to determine low expense of material; permit to determine quantitatively expense of each element separately from the elements, composing the contacts alloy; by means of these methods it is possible to evaluate quantitatively topological distribution of the matter separated from the contacts into the environment; it is possible to determine morphological characteristics of the matter separated from the contact. During investigation of the lifetime of contacts there were determined: value of the expense of the material of contacts; composition of the expense of the material of contacts; composition of the matter separated from the contact; distribution of the separated matter depending on the electrical parameters and number of the closings of contact in the case of different compositions of contacts and in different conditions. Strength of the contacts' alloys related to the electrical load was investigated at the special stand [ru

  13. Axial Field Electric Motor and Method

    National Research Council Canada - National Science Library

    Cho, Chahee P

    2007-01-01

    .... A hybrid field, brushless, permanent magnet electric motor utilizing a rotor with two sets of permanent magnets oriented such that the flux produced by the two sets of magnets is perpendicular to each...

  14. Methods for controlling pore morphology in aerogels using electric fields and products thereof

    Science.gov (United States)

    Worsley, Marcus A.; Baumann, Theodore F.; Satcher, Jr., Joe H.; Olson, Tammy Y.; Kuntz, Joshua D.; Rose, Klint A.

    2017-12-16

    In one embodiment, an aerogel or xerogel includes column structures of a material having minor pores therein and major pores devoid of the material positioned between the column structures, where longitudinal axes of the major pores are substantially parallel to one another. In another embodiment, a method includes heating a sol including aerogel or xerogel precursor materials to cause gelation thereof to form an aerogel or xerogel and exposing the heated sol to an electric field, wherein the electric field causes orientation of a microstructure of the sol during gelation, which is retained by the aerogel or xerogel. In one approach, an aerogel has elongated pores extending between a material arranged in column structures having structural characteristics of being formed from a sol exposed to an electric field that causes orientation of a microstructure of the sol during gelation which is retained by the elongated pores of the aerogel.

  15. Additional Energy Losses from Asymmetric and Non-Sinusoidal Current in an Electrical Facility and Methods of their Reduction

    Directory of Open Access Journals (Sweden)

    Tarasov Evgeniy V.

    2015-01-01

    Full Text Available Influence of the asymmetry and higher harmonics of current on the operation of an electrical facility is analyzed. The level of additional losses from the asymmetric and non-sinusoidal currents is evaluated for a 110 kV electrical network in the Siberian Region of the Russian Federation. Methods for reducing the additional energy losses in the electrical facility are suggested.

  16. Additional Energy Losses from Asymmetric and Non-Sinusoidal Current in an Electrical Facility and Methods of their Reduction

    OpenAIRE

    Tarasov, Evgeny Vladimirovich; Bulyga, Leonid Leonidovich; Ushakov, Vasily Yakovlevich; Kharlov, Nikolay Nikolaevich

    2015-01-01

    Influence of the asymmetry and higher harmonics of current on the operation of an electrical facility is analyzed. The level of additional losses from the asymmetric and non-sinusoidal currents is evaluated for a 110 kV electrical network in the Siberian Region of the Russian Federation. Methods for reducing the additional energy losses in the electrical facility are suggested.

  17. Development of advanced methods for planning electric energy distribution systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Goenen, T.; Foote, B.L.; Thompson, J.C.; Fagan, J.E.

    1979-10-01

    An extensive search was made for the identification and collection of reports published in the open literature which describes distribution planning methods and techniques. In addition, a questionnaire has been prepared and sent to a large number of electric power utility companies. A large number of these companies were visited and/or their distribution planners interviewed for the identification and description of distribution system planning methods and techniques used by these electric power utility companies and other commercial entities. Distribution systems planning models were reviewed and a set of new mixed-integer programming models were developed for the optimal expansion of the distribution systems. The models help the planner to select: (1) optimum substation locations; (2) optimum substation expansions; (3) optimum substation transformer sizes; (4) optimum load transfers between substations; (5) optimum feeder routes and sizes subject to a set of specified constraints. The models permit following existing right-of-ways and avoid areas where feeders and substations cannot be constructed. The results of computer runs were analyzed for adequacy in serving projected loads within regulation limits for both normal and emergency operation.

  18. Evaluation of the constant potential method in simulating electric double-layer capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhenxing; Laird, Brian B., E-mail: blaird@ku.edu [Department of Chemistry, University of Kansas, Lawrence, Kansas 66045 (United States); Yang, Yang; Olmsted, David L.; Asta, Mark [Department of Materials Science and Engineering, University of California, Berkeley, California 94720 (United States)

    2014-11-14

    A major challenge in the molecular simulation of electric double layer capacitors (EDLCs) is the choice of an appropriate model for the electrode. Typically, in such simulations the electrode surface is modeled using a uniform fixed charge on each of the electrode atoms, which ignores the electrode response to local charge fluctuations in the electrolyte solution. In this work, we evaluate and compare this Fixed Charge Method (FCM) with the more realistic Constant Potential Method (CPM), [S. K. Reed et al., J. Chem. Phys. 126, 084704 (2007)], in which the electrode charges fluctuate in order to maintain constant electric potential in each electrode. For this comparison, we utilize a simplified LiClO{sub 4}-acetonitrile/graphite EDLC. At low potential difference (ΔΨ ⩽ 2 V), the two methods yield essentially identical results for ion and solvent density profiles; however, significant differences appear at higher ΔΨ. At ΔΨ ⩾ 4 V, the CPM ion density profiles show significant enhancement (over FCM) of “inner-sphere adsorbed” Li{sup +} ions very close to the electrode surface. The ability of the CPM electrode to respond to local charge fluctuations in the electrolyte is seen to significantly lower the energy (and barrier) for the approach of Li{sup +} ions to the electrode surface.

  19. Evaluation of the constant potential method in simulating electric double-layer capacitors

    International Nuclear Information System (INIS)

    Wang, Zhenxing; Laird, Brian B.; Yang, Yang; Olmsted, David L.; Asta, Mark

    2014-01-01

    A major challenge in the molecular simulation of electric double layer capacitors (EDLCs) is the choice of an appropriate model for the electrode. Typically, in such simulations the electrode surface is modeled using a uniform fixed charge on each of the electrode atoms, which ignores the electrode response to local charge fluctuations in the electrolyte solution. In this work, we evaluate and compare this Fixed Charge Method (FCM) with the more realistic Constant Potential Method (CPM), [S. K. Reed et al., J. Chem. Phys. 126, 084704 (2007)], in which the electrode charges fluctuate in order to maintain constant electric potential in each electrode. For this comparison, we utilize a simplified LiClO 4 -acetonitrile/graphite EDLC. At low potential difference (ΔΨ ⩽ 2 V), the two methods yield essentially identical results for ion and solvent density profiles; however, significant differences appear at higher ΔΨ. At ΔΨ ⩾ 4 V, the CPM ion density profiles show significant enhancement (over FCM) of “inner-sphere adsorbed” Li + ions very close to the electrode surface. The ability of the CPM electrode to respond to local charge fluctuations in the electrolyte is seen to significantly lower the energy (and barrier) for the approach of Li + ions to the electrode surface

  20. Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10

    International Nuclear Information System (INIS)

    1984-02-01

    This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff-approved acceptance criteria for LOCA-related hydrodynamic loads are provided in Appendix C of this report

  1. Measurements of fatigue crack length at elevated temperature by D. C. electrical potential method

    International Nuclear Information System (INIS)

    Matsumoto, Masakatsu; Yamauchi, Isamu; Kodaira, Tsuneo

    1982-07-01

    The direct current (d.c.) electrical potential method was used to automatically and continuously measure the crack length in cyclic crack growth test at elevated temperature. This report describes some results concerning the calibration curves, i.e. the relation between electrical potential change and amount of crack extention, using SUS 304 and 2 1/4Cr-1Mo steels. It can be concluded that the measurements of fatigue crack length is possible even at elevated temperature as well as at room temperature with the equivalent accuracy. (author)

  2. Radiotracer study of the adsorption of Fe(III), Cr(III) and Cd(II) on natural and chemically modified Slovak zeolite

    International Nuclear Information System (INIS)

    Foeldesova, M.; Dillinger, P.; Lukac, P.

    1998-01-01

    In order to minimize the contamination of environment with metals in ionic form the more types of natural and chemically modified zeolites were examined to their uptake of Fe(III), Cr(III) and Cd(II) from water solutions by batch radio-exchange equilibration method. In this study was used zeolitic tuff from deposit Nizny Hrabovec (content of clinoptilolite 50-70%) with the grain size from 1.2 to 2.2 mm. The granules of zeolite were modified with the following NaOH solutions: ).5, 1, 2 and 4 mol.l -1 at 80 grad C for 4 hours. The sorption of Fe, Cr and Cd ions on all types of zeolites was studied by radio-exchange method and the sorption of Fe and Cr also flame atomic absorption method. From sorption curves the sorption coefficients were calculated. The results obtained in this work show that zeolites modified with NaOH solution are suitable for adsorption of Fe(III), Cr(III) and Cd(II) from underwater, waste water, feed water and coolant water from nuclear plants. The adsorbed zeolites can be solidified by conventional way

  3. Linearized image reconstruction method for ultrasound modulated electrical impedance tomography based on power density distribution

    International Nuclear Information System (INIS)

    Song, Xizi; Xu, Yanbin; Dong, Feng

    2017-01-01

    Electrical resistance tomography (ERT) is a promising measurement technique with important industrial and clinical applications. However, with limited effective measurements, it suffers from poor spatial resolution due to the ill-posedness of the inverse problem. Recently, there has been an increasing research interest in hybrid imaging techniques, utilizing couplings of physical modalities, because these techniques obtain much more effective measurement information and promise high resolution. Ultrasound modulated electrical impedance tomography (UMEIT) is one of the newly developed hybrid imaging techniques, which combines electric and acoustic modalities. A linearized image reconstruction method based on power density is proposed for UMEIT. The interior data, power density distribution, is adopted to reconstruct the conductivity distribution with the proposed image reconstruction method. At the same time, relating the power density change to the change in conductivity, the Jacobian matrix is employed to make the nonlinear problem into a linear one. The analytic formulation of this Jacobian matrix is derived and its effectiveness is also verified. In addition, different excitation patterns are tested and analyzed, and opposite excitation provides the best performance with the proposed method. Also, multiple power density distributions are combined to implement image reconstruction. Finally, image reconstruction is implemented with the linear back-projection (LBP) algorithm. Compared with ERT, with the proposed image reconstruction method, UMEIT can produce reconstructed images with higher quality and better quantitative evaluation results. (paper)

  4. The IFIEC method for the allocation of CO2 allowances in the EU Emissions Trading Scheme. A review applied to the electricity sector

    International Nuclear Information System (INIS)

    Bart Wesselink; Sebastian Klaus Alyssa; Gilbert Kornelis Blok

    2008-03-01

    Recently the European Commission has published a proposal to improve the function of the EU-ETS by amending the Directive which establishes the EU-ETS. The main changes proposed are the establishment of one EU-wide cap and the use of auctioning for a much greater share of allowances than is currently the case, replacing most of the allocation free of charge. Auctioning of allowances will eliminate the so-called windfall profits that occur under the current allocation free of charge that is based on historic production and emission levels; a grandfathering approach. IFIEC EUROPE, the international federation of industrial energy consumers, asked Ecofys to review the method that IFIEC has developed in recent years to allocate CO2 allowances in the EU emissions trading scheme (EU-ETS). According to IFIEC, their allocation method guarantees the same environmental outcome as other methods, without causing windfall profits and with lower risks of competitiveness loss for so-called exposed industrial users of electricity. It was decided to focus this study on the European electricity sector. This was done for several reasons: CO2 emissions from electricity generation cover a large part of the overall emission under EU-ETS, the electricity sector has a single well defined output (electricity) that can be used to illustrate the potential impact of the IFIEC benchmark based allocation approach, and electricity is a substantial cost factor for IFIEC members. This evaluation covers many aspects of IFIEC's method and compares these with two other allocation methods: auctioning and historic grandfathering. Within the IFIEC method two example approaches are evaluated: a single benchmark for electricity production and fuel-specific benchmarks for coal and gas fired electricity production. In the evaluation, we cover the following aspects: What is the IFIEC method; how does it differ from other allocation methods in character (chapter 2); What is the impact of different allocation

  5. On-line separation of Pu(III) and Am(III) using extraction and ion chromatography

    International Nuclear Information System (INIS)

    Jernstroem, J.; Lehto, J.; Betti, M.

    2007-01-01

    An on-line method developed for separating plutonium and americium was developed. The method is based on the use of HPLC pump with three analytical chromatographic columns. Plutonium is reduced throughout the procedure to trivalent oxidation state, and is recovered in the various separation steps together with americium. Light lanthanides and trivalent actinides are separated with TEVA resin in thiocyanate/formic acid media. Trivalent plutonium and americium are pre-concentrated in a TCC-II cation-exchange column, after which the separation is performed in CS5A ion chromatography column by using two different eluents. Pu(III) is eluted with a dipicolinic acid eluent, and Am(III) with oxalic acid eluent. Radiochemical and chemical purity of the eluted plutonium and americium fractions were ensured with alpha-spectrometry. (author)

  6. The reduced basis method for the electric field integral equation

    International Nuclear Information System (INIS)

    Fares, M.; Hesthaven, J.S.; Maday, Y.; Stamm, B.

    2011-01-01

    We introduce the reduced basis method (RBM) as an efficient tool for parametrized scattering problems in computational electromagnetics for problems where field solutions are computed using a standard Boundary Element Method (BEM) for the parametrized electric field integral equation (EFIE). This combination enables an algorithmic cooperation which results in a two step procedure. The first step consists of a computationally intense assembling of the reduced basis, that needs to be effected only once. In the second step, we compute output functionals of the solution, such as the Radar Cross Section (RCS), independently of the dimension of the discretization space, for many different parameter values in a many-query context at very little cost. Parameters include the wavenumber, the angle of the incident plane wave and its polarization.

  7. Frame analysis of UNNES electric bus chassis construction using finite element method

    Science.gov (United States)

    Nugroho, Untoro; Anis, Samsudin; Kusumawardani, Rini; Khoiron, Ahmad Mustamil; Maulana, Syahdan Sigit; Irvandi, Muhammad; Mashdiq, Zia Putra

    2018-03-01

    Designing the chassis needs to be done element simulation analysis to gain chassis strength on an electric bus. The purpose of this research is to get the results of chassis simulation on an electric bus when having load use FEM (Finite element method). This research was conduct in several stages of process, such as modeling chassis by Autodesk Inventor and finite element simulation software. The frame is going to be simulated with static loading by determine fixed support and then will be given the vertical force. The fixed on the frame is clamped at both the front and rear suspensions. After the simulation based on FEM it can conclude that frame is still under elastic zone, until the frame design is safe to use.

  8. Effect of pH on stability constants of Am(III)- and Cm(III)- humate complexes

    International Nuclear Information System (INIS)

    Samadfam, Mohammad; Jintoku, Takashi; Sato, Seichi; Ohashi, Hiroshi; Mitsugashira, Toshiaki; Hara, Mitsuo; Suzuki, Yoshimitsu

    1999-01-01

    The apparent stability constants of Am(III)- and Cm(III)-humate complexes were determined by dialysis method at ionic strength 0.1 in the pH range from 3.3 to 5.7 under N 2 bubbling. The Am(III) and Cm(III) loadings were about 10 -7 and 10 -10 mol/dm 3 . The concentrations of Am-241 and Cm-242 tracers were measured by α-spectrometry. It was found that the apparent stability constants were almost identical for both the Am(III)-humate and Cm(III)-humate complexes. The apparent stability constants showed a small pH-dependence, increasing from 10 4.6 at pH 3.3 to 10 5.1 at pH 5.7. The ionization of acidic functional groups of humic acid is possibly the primary factor. Above pH 6, the dialysis membrane was no langer permeable to Am(III) and Cm(III) ions and the apparent stability constant could not be experimentally obtained. The apparent stability constants between pH 6 and pH 8.5 were evaluated by considering that both binary metal-humate and ternary metal-hydroxo-humate complexes exist at pHs above 6. It was assumed that mono-hydroxo-humate complex Am(OH)HA and Cm(OH)HA are the major ternary complexes that exist below pH 9. The overall stability constants for Am(III)- and Cm(III)-humate complexes increased from 10 5.7 at pH 6 to 10 7.2 at pH 8. This implies that the formation of metal-hydroxo-humate species is preferred over the formation of hydroxide species. The apparent overall stability constants can be easily incorporated into geochemical modeling of trivalent actinide migration. The results of the present study show that the apparent stability constants determined experimentally at pH≤6 do not represent the complexation properties at higher pHs and the formation of ternary complexes should be considered in speciation calculations of radionuclides at terrestrial environment. (J.P.N.)

  9. Methods for reformation of gaseous hydrocarbons using electrical discharge

    KAUST Repository

    Cha, Min Suk

    2017-02-16

    Methods for the reformation of gaseous hydrocarbons are provided. The methods can include forming a bubble containing the gaseous hydrocarbon in a liquid. The bubble can be generated to pass in a gap between a pair of electrodes, whereby an electrical discharge is generated in the bubble at the gap between the electrodes. The electrodes can be a metal or metal alloy with a high melting point so they can sustain high voltages of up to about 200 kilovolts. The gaseous hydrocarbon can be combined with an additive gas such as molecular oxygen or carbon dioxide. The reformation of the gaseous hydrocarbon can produce mixtures containing one or more of H2, CO, H2O, CO2, and a lower hydrocarbon such as ethane or ethylene. The reformation of the gaseous hydrocarbon can produce low amounts of CO2 and H2O, e.g. about 15 mol-% or less.

  10. Methods for reformation of gaseous hydrocarbons using electrical discharge

    KAUST Repository

    Cha, Min; Zhang, Xuming

    2017-01-01

    Methods for the reformation of gaseous hydrocarbons are provided. The methods can include forming a bubble containing the gaseous hydrocarbon in a liquid. The bubble can be generated to pass in a gap between a pair of electrodes, whereby an electrical discharge is generated in the bubble at the gap between the electrodes. The electrodes can be a metal or metal alloy with a high melting point so they can sustain high voltages of up to about 200 kilovolts. The gaseous hydrocarbon can be combined with an additive gas such as molecular oxygen or carbon dioxide. The reformation of the gaseous hydrocarbon can produce mixtures containing one or more of H2, CO, H2O, CO2, and a lower hydrocarbon such as ethane or ethylene. The reformation of the gaseous hydrocarbon can produce low amounts of CO2 and H2O, e.g. about 15 mol-% or less.

  11. Determinação de ferro (III em produtos farmacêuticos por titulação fotométrica = Determination of iron (III in pharmaceutical products by photometric titration

    Directory of Open Access Journals (Sweden)

    Airton Vicente Pereira

    2011-01-01

    Full Text Available Este trabalho descreve a montagem de um sistema de titulacao fotometrica simples e de baixo custo para a determinacao de ferro (III em produtos farmaceuticos. O sistema de titulacao fotometrica foi construido utilizando-se a bomba peristaltica de um espectrofotometro convencional. O procedimento e baseado na titulacao de ferro (III com EDTA e acido salicilico como indicador. A absorcao do complexo ferro (III-acido salicilico foi monitorada espectrofotometricamente em 525 nm. O limite de quantificacao foi de 5 ƒÝg de ferro (III. O procedimento de titulacao fotometrica foi aplicado para a determinacao de ferro (III em amostras contendo sulfato ferroso e hidroxido ferrico polimaltosado. O procedimento mostrou sensibilidade, reprodutibilidade e precisao para a utilizacao em analise rotineira de ferro (III em produtos farmaceuticos.This paper describes a simple, precise and low-cost photometrictitration method for iron (III determination in pharmaceutical preparations. The photometric titration system was constructed using the peristaltic pump of a conventional spectrophotometer. The method is based on titration of iron (III with EDTA using salicylic acid as indicator. The absorption of the iron (III-salicylic acid complex wasmonitored spectrophotometrically at 525 nm. The limit of quantification was 5 ƒÝg of iron (III. The photometric titration procedure was applied for the determination of iron (III in samples of ferrous sulfate and ferric hydroxide polymaltose complex. The procedure showed sensibility, reproducibility and accuracy for use as a method for the routine analysis of iron (III in pharmaceutical formulations.

  12. Electric potential calculation in molecular simulation of electric double layer capacitors

    International Nuclear Information System (INIS)

    Wang, Zhenxing; Laird, Brian B; Olmsted, David L; Asta, Mark

    2016-01-01

    For the molecular simulation of electric double layer capacitors (EDLCs), a number of methods have been proposed and implemented to determine the one-dimensional electric potential profile between the two electrodes at a fixed potential difference. In this work, we compare several of these methods for a model LiClO 4 -acetonitrile/graphite EDLC simulated using both the traditional fixed-charged method (FCM), in which a fixed charge is assigned a priori to the electrode atoms, or the recently developed constant potential method (CPM) (2007 J. Chem. Phys . 126 084704), where the electrode charges are allowed to fluctuate to keep the potential fixed. Based on an analysis of the full three-dimensional electric potential field, we suggest a method for determining the averaged one-dimensional electric potential profile that can be applied to both the FCM and CPM simulations. Compared to traditional methods based on numerically solving the one-dimensional Poisson’s equation, this method yields better accuracy and no supplemental assumptions. (paper)

  13. EDTA excess Zn(II) back-titration in the presence of 4-(2-pyridylazo)-resorcinol indicator and naphthol green {beta} as inert dye for determining Cr(III) as Cr(III)/EDTA complex: Application of the method to a leather industry wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Venezia, M.; Alonzo, G. [Dipartimento di Ingegneria e Tecnologie Agro Forestali, Universita degli Studi di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Palmisano, L. [Dipartimento di Ingegneria Chimica dei Processi e dei Materiali, Universita degli Studi di Palermo, Viale delle Scienze, 90128 Palermo (Italy)], E-mail: palmisano@dicpm.unipa.it

    2008-03-01

    The colour changes of 4-(2-pyridylazo)-resorcinol and naphthol green {beta} as new screening metallochromic indicator in back-titration of EDTA excess with Zn(II) to determine Cr(III)/EDTA complex was investigated with the help of tristimulus colorimetry. Specific colour discrimination (SCD) and L*, a*, b* 1976 parameters were successfully applied to evaluate the quality of colour transition at the end-point in non-alkaline media and in the presence of Zn(II) and Ca(II) which resulted in non-interfering species at 1 x 10{sup -3} M and 2 x 10{sup -3} M, respectively. The above concentrations are comparable with those used for Cr(III). Validation of the fast and accurate reported method was performed by atomic absorption spectroscopy. Moreover, the method was applied for determining Cr as Cr(III) in a wastewater effluent deriving from a leather industry.

  14. Model or metaphor. More comments on the BEIR III report

    International Nuclear Information System (INIS)

    Herbert, D.E.

    1983-01-01

    Data have been obtained for Hiroshima and Nagasaki from which were prepared the estimates of somatic risk coefficients for ionizing radiation presented in the BEIR III Report. Several Poisson regression models of these data by both Bayesian and Sampling Theory methods. The results of the evaluations disclose some interesting idiosyncracies in the statistical methods by which the BEIR III estimates and inferences were obtained. The paper presents these results in the format of a textual criticism of the foundations of the received estimates of risk that are presented in the Somatic Effects Sections of the BEIR III Report. Whatever the resolution of the current difficulties with the validity of the T65 estimates of dose, the utility of any estimates of risk coefficients depends upon the suitability of the statistical methods by which any estimates of dose are mapped into estimates of risk. The statistical methods of the BEIR III Report seem idiosyncratic. Use of standard methods discloses that its rival models (LQ-L, L-L AND Q-L) may be more effective as metaphors of expression than as models of radiation response

  15. A novel technique for the treatment of stages III to IV hemorrhoids

    Science.gov (United States)

    Lin, Guoqiang; Ge, Qiongxiang; He, Xiaokang; Qi, Haixin; Xu, Li

    2017-01-01

    Abstract To compare the efficacy of homemade anal cushion suspension clamp combined with harmonic scalpel (ACS) and Milligan–Morgan hemorrhoidectomy combined with electric knife (MMH) in the treatment of stages III to IV hemorrhoids. We conducted a retrospective study of 99 patients with stages III to IV hemorrhoids hospitalized from January to December in 2013. Among them, 51 patients were treated with ACS, while 48 patients received MMH. Data from clinical recording and follow-up included operative time, intraoperative blood loss, hospitalization information, postoperative pain, and postoperative complications. Operative time, intraoperative blood loss and hospitalization time in ACS group were significantly less than those in MMH group (P hemorrhoids. PMID:28658138

  16. Electrical resistivity of ferrimagnetic magnetite thin film

    International Nuclear Information System (INIS)

    Varshney, Dinesh; Yogi, A.; Kaurav, N.; Gupta, R.P.; Phase, D.M.

    2006-01-01

    We have grown Fe 3 O 4 (III) epitaxial film on Al 2 O 3 (0001) substrate by pulsed laser deposition, with thickness of 130 nm. X-ray diffraction studies of magnetite show the spinel cubic structure of film with preferential (III) orientation. The electrical resistivity measurement demonstrates that the properties of thin film of magnetite are basically similar to those of bulk magnetite and clearly shows semiconductor-insulator transition at Verwey transition temperature (≅140 K). We have found higher Verwey transition temperature when compared with earlier reports on similar type of system. Possible causes for increase in transition temperature are discussed. (author)

  17. Transformation of Commercial Flows into Physical Flows of Electricity – Flow Based Method

    Directory of Open Access Journals (Sweden)

    M. Adamec

    2009-01-01

    Full Text Available We are witnesses of large – scale electricity transport between European countries under the umbrella of the UCTE organization. This is due to the inabilyof generators to satisfy the growing consumption in some regions. In this content, we distinguish between two types of flow. The first type is physical flow, which causes costs in the transmission grid, whilst the second type is commercial flow, which provides revenues for the market participants. The old methods for allocating transfer capacity fail to take this duality into account. The old methods that allocate transmission border capacity to “virtual” commercial flows which, in fact, will not flow over this border, do not lead to optimal allocation. Some flows are uselessly rejected and conversely, some accepted flows can cause congestion on another border. The Flow Based Allocation method (FBA is a method which aims to solve this problem.Another goal of FBA is to ensure sustainable development of expansion of transmission capacity. Transmission capacity is important, because it represents a way to establish better transmission system stability, and it provides a distribution channel for electricity to customers abroad. For optimal development, it is necessary to ensure the right division of revenue allocation among the market participants.This paper contains a brief description of the FBA method. Problems of revenue maximization and optimal revenue distribution are mentioned. 

  18. Effectively simultaneous naked-eye detection of Cu(II), Pb(II), Al(III) and Fe(III) using cyanidin extracted from red cabbage as chelating agent

    Science.gov (United States)

    Khaodee, Warangkhana; Aeungmaitrepirom, Wanlapa; Tuntulani, Thawatchai

    Simultaneous determination of Cu(II), Pb(II), Al(III) and Fe(III) using cyanidin as a chelating agent was investigated in terms of both quantitative and qualitative detections. Cyanidin was extracted and purified from red cabbage which is a local plant in Thailand. The selectivity of this method was examined by regulating the pH of cyanidin solution operated together with masking agents. It was found that Cu(II), Pb(II), Al(III) and Fe(III) simultaneously responded with the color change at pH 7, pH 6, pH 5 and pH 4, respectively. KF, DMG and the mixture of KF and DMG were used as masking agents for the determination of Fe(III), Al(III) and Pb(II), respectively. Results from naked-eye detection were evaluated by comparing with those of inductively coupled plasma (ICP), and there was no significant difference noticed. Cyanidin using as a multianalyte reagent could be employed for simultaneous determination of Cu(II), Pb(II), Al(III) and Fe(III) at the lowest concentration at 50, 80, 50 and 200 μM, respectively, by slightly varying pHs. Moreover, the proposed method could be potentially applied for real water samples with simplicity, rapidity, low cost and environmental safety.

  19. Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of photovoltaic concentrator modules and systems under natural sunlight using a normal incidence pyrheliometer. 1.2 The test method is limited to module assemblies and systems where the geometric concentration ratio specified by the manufacturer is greater than 5. 1.3 This test method applies to concentrators that use passive cooling where the cell temperature is related to the air temperature. 1.4 Measurements under a variety of conditions are allowed; results are reported under a select set of concentrator reporting conditions to facilitate comparison of results. 1.5 This test method applies only to concentrator terrestrial modules and systems. 1.6 This test method assumes that the module or system electrical performance characteristics do not change during the period of test. 1.7 The performance rating determined by this test method applies only at the period of the test, and implies no past or future performance level. 1.8...

  20. Day ahead price forecasting of electricity markets by a mixed data model and hybrid forecast method

    International Nuclear Information System (INIS)

    Amjady, Nima; Keynia, Farshid

    2008-01-01

    In a competitive electricity market, forecast of energy prices is a key information for the market participants. However, price signal usually has a complex behavior due to its nonlinearity, nonstationarity, and time variancy. In spite of all performed researches on this area in the recent years, there is still an essential need for more accurate and robust price forecast methods. In this paper, a combination of wavelet transform (WT) and a hybrid forecast method is proposed for this purpose. The hybrid method is composed of cascaded forecasters where each forecaster consists of a neural network (NN) and an evolutionary algorithms (EA). Both time domain and wavelet domain features are considered in a mixed data model for price forecast, in which the candidate input variables are refined by a feature selection technique. The adjustable parameters of the whole method are fine-tuned by a cross-validation technique. The proposed method is examined on PJM electricity market and compared with some of the most recent price forecast methods. (author)

  1. Investigation of the State of Radionuclides in Ultramicroconcentrations by the Method of a Horizontal Zone Electrophoresis in a Free Electrolyte. Ions of In(III) in Aqueous Solutions

    CERN Document Server

    Bontchev, G D; Priemyshev, A N; Bozhikov, G A; Filossofov, D V; Ivanov, P I; Maslov, O D; Milanov, M V; Dmitriev, S N

    2000-01-01

    Using the electromigration method in a free electrolyte the behaviour of In(III) in some water solutions has been investigated. Data on electrophoretic mobility of In(III) as well as its complexes with DTPA and EDTA in a wide range of pH and temperature have been collected. On the basis of experimental results the diffusion coefficient of In(III) and concentration stability constant of a complex [InDTPA]^2- have been estimated.

  2. The Moessbauer effect in Fe(III) HEDTA, Fe(III) EDTA, and Fe(III) CDTA compounds

    International Nuclear Information System (INIS)

    Prado, F.R.

    1989-01-01

    The dependence of Moessbauer spectra with pH value of Fe(III)HEDTA and Fe(III)CDTA compounds is studied. Informations on formation processes of LFe-O-FeL (L=ligand) type dimers by the relation of titration curves of Fe(III)EDTA, Fe(III)HEDTA and Fe(III)CDTA compounds with the series of Moessbauer spectra, are obtained. Some informations on Fe-O-Fe bond structure are also obtained. Comparing the titration curves with the series of Moessbauer spectra, it is concluded that the dimerization process begins when a specie of the form FeXOH α (X = EDTA, HEDTA, CDTA; α = -1, -2) arises. (M.C.K.) [pt

  3. Nonlinear electrical properties of Si three-terminal junction devices

    DEFF Research Database (Denmark)

    Fantao, Meng; Jie, Sun; Graczyk, Mariusz

    2010-01-01

    This letter reports on the realization and characterization of silicon three-terminal junction devices made in a silicon-on-insulator wafer. Room temperature electrical measurements show that the fabricated devices exhibit pronounced nonlinear electrical properties inherent to ballistic electron...... transport in a three-terminal ballistic junction (TBJ) device. The results show that room temperature functional TBJ devices can be realized in a semiconductor material other than high-mobility III-V semiconductor heterostructures and provide a simple design principle for compact silicon devices...

  4. General method for calculating polarization electric fields produced by auroral Cowling mechanism and application examples

    Science.gov (United States)

    Vanhamäki, Heikki; Amm, Olaf; Fujii, Ryo; Yoshikawa, Aki; Ieda, Aki

    2013-04-01

    The Cowling mechanism is characterized by the generation of polarization space charges in the ionosphere in consequence of a partial or total blockage of FAC flowing between the ionosphere and the magnetosphere. Thus a secondary polarization electric field builds up in the ionosphere, which guarantees that the whole (primary + secondary) ionospheric current system is again in balance with the FAC. In the Earth's ionosphere the Cowling mechanism is long known to operate in the equatorial electrojet, and several studies indicate that it is important also in auroral current systems. We present a general method for calculate the secondary polarization electric field, when the ionospheric conductances, the primary (modeled) or the total (measured) electric field, and the Cowling efficiency are given. Here the Cowling efficiency is defined as the fraction of the divergent Hall current canceled by secondary Pedersen current. In contrast to previous studies, our approach is a general solution which is not limited to specific geometrical setups (like an auroral arc), and all parameters may have any kind of spatial dependence. The solution technique is based on spherical elementary current (vector) systems (SECS). This way, we avoid the need to specify explicit boundary conditions for the searched polarization electric field or its potential, which would be required if the problem was solved in a differential equation approach. Instead, we solve an algebraic matrix equation, for which the implicit boundary condition that the divergence of the polarization electric field vanishes outside our analysis area is sufficient. In order to illustrate the effect of Cowling mechanism on ionospheric current systems, we apply our method to two simple models of auroral electrodynamic situations: 1) a mesoscale strong conductance enhancement in the early morning sector within a relatively weak southward primary electric field, 2) a morning sector auroral arc with only a weak conductance

  5. induction motor, unbalance, electrical loss, finite element method.

    Directory of Open Access Journals (Sweden)

    Camilo Andrés Cortés

    2008-09-01

    Full Text Available This paper shows the pattern of a 7.5 kW squirrel-cage induction motor’s electrical loss in balanced and unbalanced conditions, modelling the motor using the finite element method and comparing the results with experimental data obtained in the laboratory for the selected motor. Magnetic flux density variation was analysed at four places in the machine. The results so obtained sho- wed that the undervoltage unbalanced condition was the most critical from the motor’s total loss point of view. Regarding varia- tion of loss in parts of the motor, a constant iron loss pattern was found when the load was changed for each type of voltage supply and that the place where the loss had the largest rise was in the machine’s rotor.

  6. Method for electrically producing dispersions of a nonconductive fluid in a conductive medium

    Science.gov (United States)

    DePaoli, David W.; Tsouris, Constantinos; Feng, James Q.

    1998-01-01

    A method for use in electrically forming dispersions of a nonconducting fluid in a conductive medium that minimizes power consumption, gas generation, and sparking between the electrode of the nozzle and the conductive medium. The method utilizes a nozzle having a passageway, the wall of which serves as the nozzle electrode, for the transport of the nonconducting fluid into the conductive medium. A second passageway provides for the transport of a flowing low conductivity buffer fluid which results in a region of the low conductivity buffer fluid immediately adjacent the outlet from the first passageway to create the necessary protection from high current drain and sparking. An electrical potential difference applied between the nozzle electrode and an electrode in contact with the conductive medium causes formation of small droplets or bubbles of the nonconducting fluid within the conductive medium. A preferred embodiment has the first and second passageways arranged in a concentric configuration, with the outlet tip of the first passageway withdrawn into the second passageway.

  7. A METHOD OF AUTOMATIC DETERMINATION OF THE NUMBER OF THE ELECTRICAL MOTORS SIMULTANEOUSLY WORKING IN GROUP

    Directory of Open Access Journals (Sweden)

    A. V. Voloshko

    2016-11-01

    Full Text Available Purpose. Propose a method of automatic determination of the number of operating high voltage electric motors in the group of the same type based on the determination and analysis of the account data of power consumption, obtained from of electric power meters installed at the connection of motors. Results. The algorithm of the automatic determination program for the number of working in the same group of electric motors, which is based on the determination of the motor power minimum value at which it is considered on, was developed. Originality. For the first time a method of automatic determination of the number of working of the same type high-voltage motors group was proposed. Practical value. Obtained results may be used for the introduction of an automated accounting run of each motor, calculating the parameters of the equivalent induction motor or a synchronous motor.

  8. Dynamics analysis of extraction of manganese intensified by electric field

    Science.gov (United States)

    Ma, Wenrui; Tao, Changyuan; Li, Huizhan; Liu, Zuohua; Liu, Renlong

    2018-06-01

    In this study, a process reinforcement technology for leaching process of pyrolusite was developed. The electric field was introduced to decrease reaction temperature and improve the leaching rate of pyrolusite. The mechanisms of electric field intensifying leaching process of pyrolusite were investigated through X-ray diffraction (XRD), and Brunauer Emmett Teller (BET) in detail. The results showed that the electric field could decrease obviously the apparent activation energy of leaching process of pyrolusite. The apparent activation energy of the leaching of pyrolusite intensified by electric field was calculated to be 53.76 kJ.mol-1. In addition, the leaching efficiency of manganese was effectively increased by 10% to 20% than that without electric field under the same conditions. This was because that the electron conduit between Fe (II)/Fe (III) and pyrite was dredged effectively by electric field.

  9. Electrically Driven Thermal Management: Flight Validation, Experiment Development, Future Technologies

    Science.gov (United States)

    Didion, Jeffrey R.

    2018-01-01

    Electrically Driven Thermal Management is an active research and technology development initiative incorporating ISS technology flight demonstrations (STP-H5), development of Microgravity Science Glovebox (MSG) flight experiment, and laboratory-based investigations of electrically based thermal management techniques. The program targets integrated thermal management for future generations of RF electronics and power electronic devices. This presentation reviews four program elements: i.) results from the Electrohydrodynamic (EHD) Long Term Flight Demonstration launched in February 2017 ii.) development of the Electrically Driven Liquid Film Boiling Experiment iii.) two University based research efforts iv.) development of Oscillating Heat Pipe evaluation at Goddard Space Flight Center.

  10. A new method for electric impedance imaging using an eddy current with a tetrapolar circuit.

    Science.gov (United States)

    Ahsan-Ul-Ambia; Toda, Shogo; Takemae, Tadashi; Kosugi, Yukio; Hongo, Minoru

    2009-02-01

    A new contactless technique for electrical impedance imaging, using an eddy current managed along with the tetrapolar circuit method, is proposed. The eddy current produced by a magnetic field is superimposed on a constant current that is normally used in the tetrapolar circuit method, and thus is used to control the current distribution in the body. By changing the current distribution, a set of voltage differences is measured with a pair of electrodes. This set of voltage differences is used in the image reconstruction of the resistivity distribution. The least square error minimization method is used in the reconstruction algorithm. The principle of this method is explained theoretically. A backprojection algorithm was used to get 2-D images. Based on this principle, a measurement system was developed and model experiments were conducted with a saline-filled phantom. The estimated shape of each model in the reconstructed image was similar to that of the corresponding model. From the results of these experiments, it is confirmed that the proposed method is applicable to the realization of electrical conductivity imaging.

  11. Analogues of Cucurbita maxima trypsin inhibitor III (CMTI-III) with elastase inhibitory activity.

    Science.gov (United States)

    Rózycki, J; Kupryszewski, G; Rolka, K; Ragnarsson, U; Zbyryt, T; Krokoszyńska, I; Wilusz, T

    1994-04-01

    Three new CMTI-III analogues containing the Val residue in the reactive site (position 5) were synthesized by the solid-phase method. The analogues displayed an elastase inhibitory activity. It is shown that the removal of the N-terminal Arg residue and the introduction of the Gly-Pro-Gln tripeptide in the region 23-25 decreases the antielastase activity by two orders of magnitude. The removal of the disulfide bridge in positions 16-28 and the substitution of Ala for Cys16 and Gly for Cys28 decreases the activity (measured as Ka with HLE) by five orders of magnitude as compared with [Val5]CMTI-III.

  12. Th(As(III)4As(V)4O18): a mixed-valent oxoarsenic(III)/arsenic(V) actinide compound obtained under extreme conditions.

    Science.gov (United States)

    Yu, Na; Klepov, Vladislav V; Kegler, Philip; Bosbach, Dirk; Albrecht-Schmitt, Thomas E; Alekseev, Evgeny V

    2014-08-18

    A high-temperature/high-pressure method was employed to investigate phase formation in the Th(NO3)4·5H2O-As2O3-CsNO3 system. It was observed that an excess of arsenic(III) in starting system leads to the formation of Th(As(III)4As(V)4O18), which is representative of a rare class of mixed-valent arsenic(III)/arsenic(V) compounds. This compound was studied with X-ray diffraction, energy-dispersive X-ray, and Raman spectroscopy methods. Crystallographic data show that Th(As(III)4As(V)4O18) is built from (As(III)4As(V)4O18)(4-) layers connected through Th atoms. The arsenic layers are found to be isoreticular to those in previously reported As2O3 and As3O5(OH), and the geometric differences between them are discussed. Bands in the Raman spectrum are assigned with respect to the presence of AsO3 and AsO4 groups.

  13. Matrix diffusion studies by electrical conductivity methods. Comparison between laboratory and in-situ measurements

    International Nuclear Information System (INIS)

    Ohlsson, Y.; Neretnieks, I.

    1998-01-01

    Traditional laboratory diffusion experiments in rock material are time consuming, and quite small samples are generally used. Electrical conductivity measurements, on the other hand, provide a fast means for examining transport properties in rock and allow measurements on larger samples as well. Laboratory measurements using electrical conductivity give results that compare well to those from traditional diffusion experiments. The measurement of the electrical resistivity in the rock surrounding a borehole is a standard method for the detection of water conducting fractures. If these data could be correlated to matrix diffusion properties, in-situ diffusion data from large areas could be obtained. This would be valuable because it would make it possible to obtain data very early in future investigations of potentially suitable sites for a repository. This study compares laboratory electrical conductivity measurements with in-situ resistivity measurements from a borehole at Aespoe. The laboratory samples consist mainly of Aespoe diorite and fine-grained granite and the rock surrounding the borehole of Aespoe diorite, Smaaland granite and fine-grained granite. The comparison shows good agreement between laboratory measurements and in-situ data

  14. Extraction behaviour of Am(III) and Eu(III) from nitric acid medium in CMPO-HDEHP impregnated resins

    Energy Technology Data Exchange (ETDEWEB)

    Saipriya, K.; Kumar, T. [Bhabha Atomic Research Centre Facilities (India). Kalpakkam Reproscessing Plants; Kumaresan, R.; Nayak, P.K.; Venkatesan, K.A.; Antony, M.P. [Indira Gandhi Center for Atomic Research, Kalpakkam (India). Fuel Chemistry Div.

    2016-05-01

    Chromatographic resin containing extractants such as octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) or bis-(2-ethylhexyl)phosphoric acid (HDEHP) or mixture of extractants (CMPO + HDEHP) in an acrylic polymer matrix was prepared and studied for the extraction of Am(III) and Eu(III) over a range of nitric acid concentration. The effect of various parameters such as concentration of nitric acid in aqueous phase and the concentration of CMPO and HDEHP in the resin phase was studied. The distribution coefficient of Am(III) and Eu(III) in the impregnated resin increased with increased in the concentration of nitric acid for CMPO-impregnated resin, whereas a reverse trend was observed in HDEHP impregnated resin. In case of resin containing both the extractants, synergism was observed at low nitric acid concentration and antagonism at high nitric acid concentration. The mechanism of extraction was probed by slope analysis method at 0.01 and 2 M nitric acid concentrations. Citrate-buffered DTPA was used for the selective separation of Am(III), and a separation factor of 3-4 was obtained at pH 3.

  15. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    Energy Technology Data Exchange (ETDEWEB)

    Morais, A. P. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Salgado de Oliveira University, Marechal Deodoro Street, 217 – Centro, Niterói, Rio de Janeiro (Brazil); Pino, A. V. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Souza, M. N. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Electronics Department at Polytechnic School, Federal University of Rio de Janeiro, Centro de Tecnologia Bloco H sala 217, Ilha do Fundão, Rio de Janeiro (Brazil)

    2016-08-15

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  16. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    International Nuclear Information System (INIS)

    Morais, A. P.; Pino, A. V.; Souza, M. N.

    2016-01-01

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  17. Structural and electrical properties of the GexSi1-x/Si heterojunctions obtained by the method of direct bonding

    International Nuclear Information System (INIS)

    Argunova, T. S.; Belyakova, E. I.; Grekhov, I. V.; Zabrodskii, A. G.; Kostina, L. S.; Sorokin, L. M.; Shmidt, N. M.; Yi, J. M.; Jung, J. W.; Je, J. H.; Abrosimov, N. V.

    2007-01-01

    The results of studying the structural and electrical properties of structures produced by the method of direct bonding of Ge x Si 1-x and Si wafers are reported. The wafers were cut from the crystals grown by the Czochralski method. Continuity of the interface and the crystal-lattice defects were studied by X-ray methods using synchrotron radiation and by scanning electron microscopy. Measurements of the forward and reverse current-voltage characteristics of the p-Ge x Si 1-x /n-Si diodes made it possible to assess the effect of the crystallattice defects on the electrical properties of heterojunctions. Satisfactory electrical parameters suggest that the technology of direct bonding is promising for the fabrication of large-area Ge x Si 1-x /Si heterojunctions

  18. Formation factor logging in-situ by electrical methods. Background and methodology

    International Nuclear Information System (INIS)

    Loefgren, Martin; Neretnieks, Ivars

    2002-10-01

    Matrix diffusion has been identified as one of the most important mechanisms governing the retardation of radionuclides escaping from a deep geological repository for nuclear waste. Radionuclides dissolved in groundwater flowing in water-bearing fractures will diffuse into water filled micropores in the rock. Important parameters governing the matrix diffusion are the formation factor, the surface diffusion and sorption. This report focuses on the formation factor in undisturbed intrusive igneous rock and the possibility of measuring this parameter in-situ. The background to and the methodology of formation factor logging in-situ by electrical methods are given. The formation factor is here defined as a parameter only depending on the geometry of the porous system and not on the diffusing specie. Traditionally the formation factor has been measured by through diffusion experiments on core samples, which are costly and time consuming. It has been shown that the formation factor could also be measured by electrical methods that are faster and less expensive. Previously this has only been done quantitatively in the laboratory on a centimetre or decimetre scale. When measuring the formation factor in-situ in regions with saline groundwater only the rock resistivity and the pore water resistivity are needed. The rock resistivity could be obtained by a variety of geophysical downhole tools. Water-bearing fractures disturb the measurements and data possibly affected by free water has to be sorted out. This could be done without loosing too much data if the vertical resolution of the tool is high enough. It was found that the rock resistivity tool presently used by SKB are neither quantitative or have enough vertical resolution. Therefore the slimhole Dual-Laterolog from Antares was tested with good results. This tool has a high vertical resolution and gives quantitative rock resistivities that need no correction. At present there is no method of directly obtaining the

  19. Formation factor logging in-situ by electrical methods. Background and methodology

    Energy Technology Data Exchange (ETDEWEB)

    Loefgren, Martin; Neretnieks, Ivars [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    2002-10-01

    Matrix diffusion has been identified as one of the most important mechanisms governing the retardation of radionuclides escaping from a deep geological repository for nuclear waste. Radionuclides dissolved in groundwater flowing in water-bearing fractures will diffuse into water filled micropores in the rock. Important parameters governing the matrix diffusion are the formation factor, the surface diffusion and sorption. This report focuses on the formation factor in undisturbed intrusive igneous rock and the possibility of measuring this parameter in-situ. The background to and the methodology of formation factor logging in-situ by electrical methods are given. The formation factor is here defined as a parameter only depending on the geometry of the porous system and not on the diffusing specie. Traditionally the formation factor has been measured by through diffusion experiments on core samples, which are costly and time consuming. It has been shown that the formation factor could also be measured by electrical methods that are faster and less expensive. Previously this has only been done quantitatively in the laboratory on a centimetre or decimetre scale. When measuring the formation factor in-situ in regions with saline groundwater only the rock resistivity and the pore water resistivity are needed. The rock resistivity could be obtained by a variety of geophysical downhole tools. Water-bearing fractures disturb the measurements and data possibly affected by free water has to be sorted out. This could be done without loosing too much data if the vertical resolution of the tool is high enough. It was found that the rock resistivity tool presently used by SKB are neither quantitative or have enough vertical resolution. Therefore the slimhole Dual-Laterolog from Antares was tested with good results. This tool has a high vertical resolution and gives quantitative rock resistivities that need no correction. At present there is no method of directly obtaining the

  20. An Effective Measured Data Preprocessing Method in Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Chenglong Yu

    2014-01-01

    Full Text Available As an advanced process detection technology, electrical impedance tomography (EIT has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes.

  1. Electricity

    CERN Document Server

    Basford, Leslie

    2013-01-01

    Electricity Made Simple covers the fundamental principles underlying every aspect of electricity. The book discusses current; resistance including its measurement, Kirchhoff's laws, and resistors; electroheat, electromagnetics and electrochemistry; and the motor and generator effects of electromagnetic forces. The text also describes alternating current, circuits and inductors, alternating current circuits, and a.c. generators and motors. Other methods of generating electromagnetic forces are also considered. The book is useful for electrical engineering students.

  2. Ion implantation and annealing studies in III-V nitrides

    International Nuclear Information System (INIS)

    Zolper, J.C.; Pearton, S.J.

    1996-01-01

    Ion implantation doping and isolation is expected to play an enabling role for the realization of advanced III-Nitride based devices. In fact, implantation has already been used to demonstrate n- and p-type doping of GaN with Si and Mg or Ca, respectively, as well as to fabricate the first GaN junction field effect transistor. Although these initial implantation studies demonstrated the feasibility of this technique for the III-Nitride materials, further work is needed to realize its full potential. After reviewing some of the initial studies in this field, the authors present new results for improved annealing sequences and defect studies in GaN. First, sputtered AlN is shown by electrical characterization of Schottky and Ohmic contacts to be an effect encapsulant of GaN during the 1,100 C implant activation anneal. The AlN suppresses N-loss from the GaN surface and the formation of a degenerate n + -surface region that would prohibit Schottky barrier formation after the implant activation anneal. Second, they examine the nature of the defect generation and annealing sequence following implantation using both Rutherford Backscattering (RBS) and Hall characterization. They show that for a Si-dose of 1 x 10 16 cm -2 50% electrical donor activation is achieved despite a significant amount of residual implantation-induced damage in the material

  3. Sorption of trace amounts of gallium (III) on iron (III) oxide

    International Nuclear Information System (INIS)

    Music, S.; Gessner, M.; Wolf, R.H.H.

    1979-01-01

    The sorption of trace amounts of gallium(III) on iron(III) oxide has been studied as a function of pH. Optimum conditions have been found for the preconcentration of traces of gallium(III) by iron(III) oxide. The influence of surface active substances and of complexing agents on the sorption of trace amounts of gallium(III) on iron(III) oxide has been also studied. (orig.) [de

  4. Sorption of trace amounts of gallium (III) on iron (III) oxide

    Energy Technology Data Exchange (ETDEWEB)

    Music, S; Gessner, M; Wolf, R H.H. [Institut Rudjer Boskovic, Zagreb (Yugoslavia)

    1979-01-01

    The sorption of trace amounts of gallium(III) on iron(III) oxide has been studied as a function of pH. Optimum conditions have been found for the preconcentration of traces of gallium(III) by iron(III) oxide. The influence of surface active substances and of complexing agents on the sorption of trace amounts of gallium(III) on iron(III) oxide has been also studied.

  5. Costs of electric power generation in different types of power plants

    International Nuclear Information System (INIS)

    Weible, H.

    1977-01-01

    In the framework of our study 'energy - environment - industry' we need among other things the costs of electric power generation. We register their structure in a sub-model. Recently there was disagreement on effective costs of electric power generation particularly when comparing fossil-fuel power plants to nuclear power plants. For this reason, expertises on the costs of electric power generation in nuclear and fossil-fuel power plants were ordered with the Energy-Economic Institute in Cologne as well as with the Battelle Institute in Frankfurt. In the framwork of our paper on the system 'energy - environment - industry' we do not want to give new data potentially required for our task, before the expertises will be finished. Therefore the results given in part III of this lecture are only meant as an example in order to show possible consequences of the cost programs set up, depending on initial data whose general recognition is to be aimed at. Furthermore, the theoretical approach to investment calculation has to win general recognition when recording calculation methods computer-compatibly. Any new formulations discussed in industrial management have not been taken into account. (orig.) [de

  6. Determination of Chromium(III), Chromium(VI), and Chromium(III) acetylacetonate in water by ion-exchange disk extraction/metal furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Kamakura, Nao; Inui, Tetsuo; Kitano, Masaru; Nakamura, Toshihiro

    2014-01-01

    A new method for the separate determination of Chromium(III) (Cr(III)), Chromium(VI) (Cr(VI)), and Cr(III) acetylacetonate (Cr(acac) 3 ) in water was developed using a cation-exchange extraction disk (CED) and an anion-exchange extraction disk (AED) combined with metal furnace atomic absorption spectrometry (MFAAS). A 100-mL water sample was adjusted to pH 5.6 and passed through the CED placed on the AED. Cr(acac) 3 and Cr(III) were adsorbed on the CED, and Cr(VI) was adsorbed on the AED. The adsorbed Cr(acac) 3 was eluted with 50 mL of carbon tetrachloride, followed by the elution of Cr(III) with 50 mL of 3 mol L −1 nitric acid. Cr(VI) was eluted with 50 mL of 3 mol L −1 nitric acid. The chemical species of Cr eluted from the CED with carbon tetrachloride was identified as Cr(acac) 3 using infrared spectroscopy. The eluate of Cr(acac) 3 was diluted to 100 mL with carbon tetrachloride, and those of Cr(III) and Cr(VI) were diluted to 100 mL with deionized water. All of the solutions were subsequently analyzed by MFAAS. The calibration curve for the Cr(acac) 3 aqueous solutions exhibited good linearity in the range of 0.1 to 1 ng. The detection limit of Cr, which corresponded to three times the standard deviation (n = 10) of the blank values, was 20 pg. The recovery test for Cr(III), Cr(VI), and Cr(acac) 3 exhibited desirable results (96.0%–107%) when 5 μg of each species (50 μg L −1 ) was added to 100 mL water samples (i.e., tap water, rainwater, and bottled drinking water). In a humic acid solution, Cr(acac) 3 was quantitatively recovered (103%), but Cr(III) and Cr(VI) exhibited poor recoveries (i.e., 84.8% and 78.4%, respectively). - Highlights: • A determination method of Cr(III), Cr(VI), and Cr(III) acetylacetonate in water was developed. • The combination of ion-exchange resin disks with metal furnace AAS was used. • No effect of humic acid on the recovery of Cr(III) acetylacetonate was observed. • The proposed method enabled the determination

  7. ROSA-III 200% double-ended break integral test RUN 901

    International Nuclear Information System (INIS)

    Nakamura, Hideo; Tasaka, Kanji; Koizumi, Yasuo; Anoda, Yoshinari; Kumamaru, Hiroshige; Murata, Hideo; Suzuki, Mitsuhiro; Shiba, Masayoshi

    1984-02-01

    This report presents the experimental data of RUN 901, a 200% double-ended break test at the recirculation pump suction line with the ROSA-III test facility. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6. The facility has the electrically heated core, the break simulator and the scaled ECCS (Emergency Core Cooling System). The MSIV closure and the ECCS actuation were tripped by the liquid level in the upper downcomer. The channel inlet flows were measured by differential pressure transducers installed at the channel inlet orifices of the fuel assembly No.4. The PCT (Peak Cladding Temperature) was 780 K occured during the blowdown phase in RUN 901. The whole core was quenched after the ECCS actuation and the effectiveness of ECCS has been confirmed. (author)

  8. Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography

    International Nuclear Information System (INIS)

    Grasland-Mongrain, Pol; Destrempes, François; Cloutier, Guy; Mari, Jean-Martial; Souchon, Rémi; Catheline, Stefan; Chapelon, Jean-Yves; Lafon, Cyril

    2015-01-01

    Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an ‘acousto-electrical speckle’ in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging. (paper)

  9. Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography

    Science.gov (United States)

    Grasland-Mongrain, Pol; Destrempes, François; Mari, Jean-Martial; Souchon, Rémi; Catheline, Stefan; Chapelon, Jean-Yves; Lafon, Cyril; Cloutier, Guy

    2015-05-01

    Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an ‘acousto-electrical speckle’ in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging.

  10. Electric-drive tractability indicator integrated in hybrid electric vehicle tachometer

    Science.gov (United States)

    Tamai, Goro; Zhou, Jing; Weslati, Feisel

    2014-09-02

    An indicator, system and method of indicating electric drive usability in a hybrid electric vehicle. A tachometer is used that includes a display having an all-electric drive portion and a hybrid drive portion. The all-electric drive portion and the hybrid drive portion share a first boundary which indicates a minimum electric drive usability and a beginning of hybrid drive operation of the vehicle. The indicated level of electric drive usability is derived from at least one of a percent battery discharge, a percent maximum torque provided by the electric drive, and a percent electric drive to hybrid drive operating cost for the hybrid electric vehicle.

  11. Controlling the emission wavelength in group III-V semiconductor laser diodes

    KAUST Repository

    Ooi, Boon S.

    2016-12-29

    Methods are provided for modifying the emission wavelength of a semiconductor quantum well laser diode, e.g. by blue shifting the emission wavelength. The methods can be applied to a variety of semiconductor quantum well laser diodes, e.g. group III-V semiconductor quantum wells. The group III-V semiconductor can include AlSb, AlAs, Aln, AlP, BN, GaSb, GaAs, GaN, GaP, InSb, InAs, InN, and InP, and group III-V ternary semiconductors alloys such as AlxGai.xAs. The methods can results in a blue shifting of about 20 meV to 350 meV, which can be used for example to make group III-V semiconductor quantum well laser diodes with an emission that is orange or yellow. Methods of making semiconductor quantum well laser diodes and semiconductor quantum well laser diodes made therefrom are also provided.

  12. Articulación de fones en individuos clase esqueletal I,II y III Speech patterns in skeletal class I, II and III subjects

    Directory of Open Access Journals (Sweden)

    Pía Villanueva

    2009-09-01

    Full Text Available OBJETIVO: determinar los patrones de articulación de fones consonánticos en sujetos de habla española chilena clases I, II y III esqueletal; comparar las diferencias fonéticas que existan entre clases esqueletales. MÉTODOS: se seleccionaron 54 individuos que cumplían con los criterios de inclusión determinados mediante un examen clínico intraoral y a través del análisis de Ricketts, y se conformaron los grupos de estudio de pacientes clases esqueletales I, II y III. Se les realizó un examen fonoarticulatorio estandarizado para determinar los fones modificados y el patrón articulatorio compensatorio realizado. RESULTADOS: se observaron cambios en el punto de articulación de fones consonánticos en las tres clases esqueletales, con diferencias significativas en los grupos de fones anteriores y medios entre pacientes clases I y II, sólo en el grupo de los fones anteriores entre pacientes I y III. Entre pacientes clases II y III no se observaron diferencias significativas. Se reportan modificaciones y compensaciones cualitativamente distintas entre las clases esqueletales. CONCLUSIONES: en relación a pacientes clase I, los pacientes clase II o III, presentan distinto grado de modificación en el punto de articulación de fones consonánticos. Las diferencias observadas se relacionan con los patrones esqueletales propios de cada clase.PURPOSE: to determine the consonant phonemes articulation patterns in Chilean skeletal class I, II and III Spanish speakers and compare their phonetic differences. METHODS: fifty-four skeletal class I, II and III subjects were selected, based on intraoral clinical examination and Ricketts cephalometric analysis, constituting the study groups. A standardized phonoarticulatory test was applied to each patient to determine the modified phonemes and their compensatory patterns. RESULTS: the findings indicate changes in articulation in all three groups. Significant differences were found in anterior and medium

  13. Test methods for evaluating energy consumption and emissions of vehicles with electric, hybrid and fuel cell power trains

    NARCIS (Netherlands)

    Smokers, R.T.M.; Ploumen, S.; Conte, M.; Buning, L.; Meier-Engel, K.

    2000-01-01

    As part of the MATADOR-project measurement methods have been developed for the evaluation of the energy consumption and emissions of vehicles with advanced propulsion systems, such as battery-electric, hybrid electric and fuel cell vehicles. Based on an inventory of existing and prospective standard

  14. WISC-III e WAIS-III na avaliação da inteligência de cegos WISC-III/WAIS-III en ciegos WISC-III and WAIS-III in intellectual assessment of blind people

    Directory of Open Access Journals (Sweden)

    Elizabeth do Nascimento

    2007-12-01

    Full Text Available Diante da escassez de pesquisas nacionais e de testes psicológicos destinados a avaliar pessoas cegas, desenvolveu-se um estudo psicométrico com as escalas verbais dos testes WISC-III e WAIS-III. Após as adaptações de alguns estímulos e das instruções, os testes foram aplicados em crianças (N = 120 e adultos (N = 52 residentes em Belo Horizonte. Os resultados indicaram que as escalas verbais modificadas apresentam uma boa consistência interna (alfa> 0,80. Além disso, a investigação da validade fatorial identifica a presença clara de apenas um componente. Este componente explica 81% e 64% para o WISC-III e WAIS-III, respectivamente. Conclui-se que as adaptações a que se procedeu não afetaram a estrutura fatorial das escalas. Deste modo, os profissionais poderão utilizar as escalas modificadas para avaliar a inteligência de pessoas cegas.Frente a la escasez de investigaciones nacionales asi como la ausencia de tests psicológicos que evaluen personas ciegas, se ha desarrollado un estudio psicometrico com la escalas verbales del WISC-III y WAIS-III. Posteriormente a las adaptaciones de algunos estímulos y de las instrucciones, las escalas fueron aplicadas a una muestra de niños (n=120 y de adultos (n=52 residentes en la ciudad de Belo Horizonte-Brasil. Los resultados indican que las escalas verbales modificadas presentan una alta fiabilidad (alpha >0,80 asi como la presencia clara de un unico componente responsable por 81% y 64% de la variancia del WIC-III e WAIS-III respectivamente. Se ha concluido que las modificaciones efectuadas no han comprometido la estructura factorial de las escalas verbales. Por tanto, los profesionales psicólogos pueden utilizar las escalas modificadas para la evaluación de la inteligencia de personas portadoras de ceguera.Owing to the almost lack of a national research on psychological testing for the evaluation of blind people, a psychometric study has been developed with the WISC-III and WAIS-III

  15. Probabilistic numerical methods for high-dimensional stochastic control and valuation problems on electricity markets

    International Nuclear Information System (INIS)

    Langrene, Nicolas

    2014-01-01

    This thesis deals with the numerical solution of general stochastic control problems, with notable applications for electricity markets. We first propose a structural model for the price of electricity, allowing for price spikes well above the marginal fuel price under strained market conditions. This model allows to price and partially hedge electricity derivatives, using fuel forwards as hedging instruments. Then, we propose an algorithm, which combines Monte-Carlo simulations with local basis regressions, to solve general optimal switching problems. A comprehensive rate of convergence of the method is provided. Moreover, we manage to make the algorithm parsimonious in memory (and hence suitable for high dimensional problems) by generalizing to this framework a memory reduction method that avoids the storage of the sample paths. We illustrate this on the problem of investments in new power plants (our structural power price model allowing the new plants to impact the price of electricity). Finally, we study more general stochastic control problems (the control can be continuous and impact the drift and volatility of the state process), the solutions of which belong to the class of fully nonlinear Hamilton-Jacobi-Bellman equations, and can be handled via constrained Backward Stochastic Differential Equations, for which we develop a backward algorithm based on control randomization and parametric optimizations. A rate of convergence between the constraPned BSDE and its discrete version is provided, as well as an estimate of the optimal control. This algorithm is then applied to the problem of super replication of options under uncertain volatilities (and correlations). (author)

  16. Ion temperatures in TORTUR III

    International Nuclear Information System (INIS)

    Hendriks, F.B.

    1985-12-01

    Spatially resolved ion-energy distributions are presented for discharges in the TORTUR III tokamak. The measurements are performed in an active method, using a neutral hydrogen probing beam of 20-30 keV, to enhance charge-exchange processes along its path, as well as by the usual passive method. Ion temperatures can amount up to 1 keV

  17. Identifying critical constraints for the maximum loadability of electric power systems - analysis via interior point method

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Luciano Vitoria [Sul-riograndense Federal Institute for Education, Science and Technology (IFSul), Pelotas, RS (Brazil)], E-mail: luciano@pelotas.ifsul.edu.br

    2009-07-01

    This paper presents an overview about the maximum load ability problem and aims to study the main factors that limit this load ability. Specifically this study focuses its attention on determining which electric system buses influence directly on the power demand supply. The proposed approach uses the conventional maximum load ability method modelled by an optimization problem. The solution of this model is performed using the Interior Point methodology. As consequence of this solution method, the Lagrange multipliers are used as parameters that identify the probable 'bottlenecks' in the electric power system. The study also shows the relationship between the Lagrange multipliers and the cost function in the Interior Point optimization interpreted like sensitivity parameters. In order to illustrate the proposed methodology, the approach was applied to an IEEE test system and to assess its performance, a real equivalent electric system from the South- Southeast region of Brazil was simulated. (author)

  18. Magnetic exchange in {Gd(III)-radical} complexes: method assessment, mechanism of coupling and magneto-structural correlations.

    Science.gov (United States)

    Gupta, Tulika; Rajeshkumar, Thayalan; Rajaraman, Gopalan

    2014-07-28

    Density functional studies have been performed on ten different {Gd(III)-radical} complexes exhibiting both ferro and antiferromagnetic exchange interaction with an aim to assess a suitable exchange-correlation functional within DFT formalism. This study has also been extended to probe the mechanism of magnetic coupling and to develop suitable magneto-structural correlations for this pair. Our method assessments reveal the following order of increasing accuracy for the evaluation of J values compared to experimental coupling constants: B(40HF)LYP X3LYP < B3LYP < B2PLYP. Grimme's double-hybrid functional is found to be superior compared to other functionals tested and this is followed very closely by the conventional hybrid B3LYP functional. At the basis set front, our calculations reveal that the incorporation of relativistic effect is important in these calculations and the relativistically corrected effective core potential (ECP) basis set is found to yield better Js compared to other methods. The supposedly empty 5d/6s/6p orbitals of Gd(III) are found to play an important role in the mechanism of magnetic coupling and different contributions to the exchange terms are probed using Molecular Orbital (MO) and Natural Bond Orbital (NBO) analysis. Magneto-structural correlations for Gd-O distances, Gd-O-N angles and Gd-O-N-C dihedral angles are developed where the bond angles as well as dihedral angle parameters are found to dictate the sign and strength of the magnetic coupling in this series.

  19. DISTRIBUTED ELECTRICAL POWER PRODUCTION SYSTEM AND METHOD OF CONTROL THEREOF

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a distributed electrical power production system wherein two or more electrical power units comprise respective sets of power supply attributes. Each set of power supply attributes is associated with a dynamic operating state of a particular electrical power unit....

  20. Geophysical methods in protected environments. Electrical resistivity tomography

    International Nuclear Information System (INIS)

    Rubio Sánchez-Aguililla, F.M.; Ramiro-Camacho, A.; Ibarra Torre, P.

    2017-01-01

    There is a strong interest in protecting the environment with the aim of its long term preservation. Sometimes the heritage value of these natural areas is related to their biodiversity as there are restricted ecosystems that depend directly on them. In other cases there a singular geological record might exist, essential for the understanding of certain processes affecting the planet, such as volcanic events or glacial periods. To achieve the protection and conservation of these areas it is necessary to generate knowledge about the distribution of geological materials and groundwater masses, to study the parameters that dominate the behaviour of these systems and then define those elements that require special protection or attention. In these protected environments, research methods with a minimal environmental impact should be used. Therefore, indirect methods, such as geophysical techniques, are reliable and complementary tools with a minimum environmental impact and are therefore useful for research these unique areas. The IGME has conducted several geophysical surveys in different protected environments in Spain with the aim of achieving a better understanding, and thus facilitate their preservation and exploitation in a sustainable manner. In this paper we present a review of some case studies where geophysical methods have been used. In all the cases electrical resistivity tomography has been the axis of the geophysical research and stands out due to its great effectiveness. The main objective of this communication is to divulgate and increase awareness of the important role that these geophysical methods can play in the sustainable study of these unique places. [es

  1. Chemical Detection using Electrically Open Circuits having no Electrical Connections

    Science.gov (United States)

    Woodward, Stanley E.; Olgesby, Donald M.; Taylor, Bryant D.; Shams, Qamar A.

    2008-01-01

    This paper presents investigations to date on chemical detection using a recently developed method for designing, powering and interrogating sensors as electrically open circuits having no electrical connections. In lieu of having each sensor from a closed circuit with multiple electrically connected components, an electrically conductive geometric pattern that is powered using oscillating magnetic fields and capable of storing an electric field and a magnetic field without the need of a closed circuit or electrical connections is used. When electrically active, the patterns respond with their own magnetic field whose frequency, amplitude and bandwidth can be correlated with the magnitude of the physical quantities being measured. Preliminary experimental results of using two different detection approaches will be presented. In one method, a thin film of a reactant is deposited on the surface of the open-circuit sensor. Exposure to a specific targeted reactant shifts the resonant frequency of the sensor. In the second method, a coating of conductive material is placed on a thin non-conductive plastic sheet that is placed over the surface of the sensor. There is no physical contact between the sensor and the electrically conductive material. When the conductive material is exposed to a targeted reactant, a chemical reaction occurs that renders the material non-conductive. The change in the material s electrical resistance within the magnetic field of the sensor alters the sensor s response bandwidth and amplitude, allowing detection of the reaction without having the reactants in physical contact with the sensor.

  2. Electric Sensors for Express-Method Checking of Liquid Quality Level Monitoring

    Directory of Open Access Journals (Sweden)

    Petro STOLYARCHUK

    2010-02-01

    Full Text Available The research covered in the suggested article is meant for ecological monitoring in the broad sense. The express-method of water solution quality level estimation and the technique of fast response to the quality level of industrial, agricultural and domestic wastewaters along with food products are proposed. The novelty of the proposed technique roots in the implementation of suggested methods and means of electric parameter measurement aimed at the quality index controlling of nonelectric qualimetry objects. Relevant research includes the exploration of water-solutions as well as different-level purification of industrial and domestic spillage waters, colloid solutions (cream, milk with the known contaminants, mixtures of superficially active substances and chlorine-containing substances.

  3. Determination of Chromium(III) Picolinate Using High Performance Liquid Chromatography-Ultraviolet Spectrophotometry

    International Nuclear Information System (INIS)

    Kim, Sung Il; Woo, Dong Jin; Kang, Dae Kyung; Lee, Myung Hee; Woo, Gun Jo; Cha, Ki Won

    2003-01-01

    Cr-(pic) 3 has been widely used as food additives, drugs, and feed additives. Accordingly, its determination method should be established. In the present paper, we have studied the determination method of chromium(III) picolinate accurately using ESI-MS on-lined with HPLC. Chromium(III) picolinate in feed products was determined successfully. Chromium(III) is very well known as an essential mineral. It is suggested as a cofactor in the maintenance of both normal lipid and carbohydrate metabolism by assisting the action of insulin on a cell membrane. According to the National Research Council, the daily recommended intake of chromium(III) is 50-200 μg. Several organic chromium(III) complexes have been reported to have significantly higher absorption and tissue incorporation activity than inorganic salts such as chromium(III) chloride

  4. Effect of transcutaneous electrical stimulation treatment on lower urinary tract symptoms after class III radical hysterectomy in cervical cancer patients: study protocol for a multicentre, randomized controlled trial.

    Science.gov (United States)

    Sun, Xiu-Li; Wang, Hai-Bo; Wang, Zhi-Qi; Cao, Ting-Ting; Yang, Xin; Han, Jing-Song; Wu, Yang-Feng; Reilly, Kathleen H; Wang, Jian-Liu

    2017-06-15

    Class III radical hysterectomy (RH III)_plus pelvic lymphadenectomy is the standard surgery for early stage cervical cancer (CC) patients, the 5 year survival rate is about 90%, but pelvic floor disorders especially bladder dysfunction are common due to damaged vessels and nerve fibers following surgery. Transcutaneous electrical stimulation (TENS) treatment has been used to treat bladder disorders for many years, but its effect on cervical cancer patients, the best treatment time point and stimulated protocol, had never been assessed. The aim of this study is to investigate the efficacy of TENS treatment on lower urinary tract symptoms (LUTS) after RH III in CC patients. The study will be conducted as a clinical, multicentre, randomised controlled trial with balanced randomisation (1:1). The planned sample size is 208 participants (at 1:1 ratio, 104 subjects in each group). At 5-7 days after RH III, patients are screened according to operative and pathological findings. Enrolled participants are randomised into an intervention group (TENS plus conventional clinical care) or control group (conventional clinical care), with stratification by menopausal status (menopause vs. non-menopause) and surgical modality (laparoscopic RH or abdominal RH). Participants in both groups will be followed up at 14 days, 21 days, 28 days, 3 months, 6 months, 12 months, 18 months and 24 months after surgery. The primary endpoint is improvement rate of urination function which is defined as recovery (residual urine ≤50 ml) or improvement (residual urine 50-100 ml). Secondary endpoints include urodynamic parameter, urinary incontinence, anorectal function, pelvic function, quality of life (QOL), disease-free survival and adverse events. Primary endpoint analyses will be carried out by Cochran-Mantel-Haenszel tests taking into center effect. To our knowledge this is the first trial to investigate the effect of TENS treatment on bladder function recovery after RH III among

  5. The Effect of Herrmann Whole Brain Teaching Method on Students' Understanding of Simple Electric Circuits

    Science.gov (United States)

    Bawaneh, Ali Khalid Ali; Nurulazam Md Zain, Ahmad; Salmiza, Saleh

    2011-01-01

    The purpose of this study was to investigate the effect of Herrmann Whole Brain Teaching Method over conventional teaching method on eight graders in their understanding of simple electric circuits in Jordan. Participants (N = 273 students; M = 139, F = 134) were randomly selected from Bani Kenanah region-North of Jordan and randomly assigned to…

  6. Hybrid finite element method for describing the electrical response of biological cells to applied fields.

    Science.gov (United States)

    Ying, Wenjun; Henriquez, Craig S

    2007-04-01

    A novel hybrid finite element method (FEM) for modeling the response of passive and active biological membranes to external stimuli is presented. The method is based on the differential equations that describe the conservation of electric flux and membrane currents. By introducing the electric flux through the cell membrane as an additional variable, the algorithm decouples the linear partial differential equation part from the nonlinear ordinary differential equation part that defines the membrane dynamics of interest. This conveniently results in two subproblems: a linear interface problem and a nonlinear initial value problem. The linear interface problem is solved with a hybrid FEM. The initial value problem is integrated by a standard ordinary differential equation solver such as the Euler and Runge-Kutta methods. During time integration, these two subproblems are solved alternatively. The algorithm can be used to model the interaction of stimuli with multiple cells of almost arbitrary geometries and complex ion-channel gating at the plasma membrane. Numerical experiments are presented demonstrating the uses of the method for modeling field stimulation and action potential propagation.

  7. System and method for integration of renewable energy and fuel cell for the production of electricity and hydrogen

    NARCIS (Netherlands)

    Hemmes, K.

    2007-01-01

    The invention relates to a system and method for integrating renewable energy and a fuel cell for the production of electricity and hydrogen, wherein this comprises the use of renewable energy as fluctuating energy source for the production of electricity and also comprises the use of at least one

  8. Potentiometric studies on some ternary complexes of Nd(III), Sm(III), Gd(III) and Ho(III) with cyclohexanediaminetetraacetic acid as primary ligand

    International Nuclear Information System (INIS)

    Marathe, D.G.; Munshi, K.N.

    1983-01-01

    The formation constants of the ternary complexes of neodymium(III), samarium(III), gadlonium(III) and holmium(III) with cyclohexanediaminetetraacetic acid (CyDTA) as primary ligand and dihydroxynaphthalene (DHN), dihydroxynaphthalene-6-sulphonic acid (DHNSA) and cateechol-3,5-disulphonic acid (CDSA) as secondary ligands have been investigated by potentiometric titration technique. The secondary ligands have been investigated by potentiometric titration technique. The values of formation constants of 1:1:1 ternary chelates are reported at three different temperatures, and at a fixed ionic strength, μ = 0.1 M (NaClO 4 ). (author)

  9. Complexation of biological ligands with lanthanides(III) for MRI: Structure, thermodynamic and methods; Complexation des cations lanthanides trivalents par des ligands d'origine biologique pour l'IRM: Structure, thermodynamique et methodes

    Energy Technology Data Exchange (ETDEWEB)

    Bonnet, C

    2006-07-15

    New cyclic ligands derived from sugars and amino-acids form a scaffold carrying a coordination sphere of oxygen atoms suitable to complex Ln(III) ions. In spite of their rather low molecular weights, the complexes display surprisingly high relaxivity values, especially at high field. The ACX and BCX ligands, which are acidic derivatives of modified and cyclo-dextrins, form mono and bimetallic complexes with Ln(III). The LnACX and LnBCX complexes show affinities towards Ln(III) similar to those of tri-acidic ligands. In the bimetallic Lu2ACX complex, the cations are deeply embedded in the cavity of the ligand, as shown by the X-ray structure. In aqueous solution, the number of water molecules coordinated to the cation in the LnACX complex depends on the nature and concentration of the alkali ions of the supporting electrolyte, as shown by luminescence and relaxometric measurements. There is only one water molecule coordinated in the LnBCX complex, which enables us to highlight an important second sphere contribution to relaxivity. The NMR study of the RAFT peptidic ligand shows the complexation of Ln(III), with an affinity similar to those of natural ligands derived from calmodulin. The relaxometric study also shows an important second sphere contribution to relaxivity. To better understand the intricate molecular factors affecting relaxivity, we developed new relaxometric methods based on probe solutes. These methods allow us to determine the charge of the complex, weak affinity constants, trans-metallation constants, and the electronic relaxation rate. (author)

  10. Application of multi-criteria methods to compare different solutions of supplying buildings in electricity from photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Mendecka Barbara

    2016-01-01

    Full Text Available Nowadays, the technologies of electricity generation in distributed systems are usually associated with Renewable Energy Sources (RES. The choice of the construction site depends mainly on the availability of the power system. However, energy planning, especially in case of RES, is a complex process involving multiple and often conflicting objectives. The complexity of the selection of the electricity system is typically addressed with the use of multi-criteria tools, involving all of the considered criteria and also different methods of their aggregation. The result is a final ranking of the available alternatives. This paper describes the application of a multi-criteria decision tool for the comparative analysis of the use of alternative options of the PV technology for electricity production. Four decision variants are considered, including the different construction of solar farms (static and movable structure and different types of configuration of individual installation (off and on-grid. The construction of each new sources of electricity generation, including PV, is the multi-threaded and multi-dimensional decision problem. The criteria used in the analysis combine economic, environmental and social issues. The first of the considered criterion is the Net Present Value (NPV which determines the economic viability of the project. The second criterion, thermo-ecological cost (TEC, connecting energy and environmental issues. Finally, the Land Use (LU is considered as a social criterion. As aggregation function, the Weighted Sum Method (WSM is used. The sensitivity analysis of the criteria weights was performed with the use of a novel method involving Monte Carlo simulation and a method of data reconciliation.

  11. Degradation diagnosing method for low voltage electric wire and cable in nuclear facility

    International Nuclear Information System (INIS)

    Kamimura, Seiji; Seki, Ikuo; Yagyu, Hideki; Onishi, Takao; Kusama, Yasuo.

    1991-01-01

    A considerable skill is required for a visual inspection method which has been used most widely for determining the degradation of low voltage electric wires and cables used mostly in facilities such as nuclear power plants. It is extremely difficult to determine the degradation accurately and appropriately even for skilled inspectors because of individual difference. Then, a small amount of organic insulation materials is taken as a sample from insulators or sheath materials actually disposed. The pyrolytic temperature of the sample is measured by thermal gravimetric analysis to determine the extent of the degradation of the electric wire and cable based on the relationship between the degradation and the elongation. Since there is a close relationship between the temperature at which the measured weight of the sample is reduced by 5% and the degradation behavior of the mechanical property, analysis can be conducted effectively by an extremely small amount of the sample. Since the insulation degradation of relatively low voltage electric wires and cables can be determined in a non-destructive manner at high accuracy, the lifetime can be forecasted. (N.H.)

  12. Solvent effects on extraction of aluminum(III), gallium(III), and indium(III), with decanoic acid

    International Nuclear Information System (INIS)

    Yamada, Hiromichi; Hayashi, Hisao; Fujii, Yukio; Mizuta, Masateru

    1986-01-01

    Extraction of aluminum(III) and indium(III) with decanoic acid in 1-octanol was carried out at 25 deg C and at an aqueous ionic strength of 0.1 mol dm -3 (NaClO 4 ). Monomeric and tetrameric aluminum(III) decanoates and monomeric indium(III) decanoate are responsible for the extraction. From a comparison of the present results with those obtained from the previous works, the polymerization of the extracted species was found to be more extensive in benzene than in 1-octanol, and the metal decanoates were highly polymerized in the following order in both solvents: Al > Ga > In. (author)

  13. Method to Calculate the Electricity Generated by a Photovoltaic Cell, Based on Its Mathematical Model Simulations in MATLAB

    Directory of Open Access Journals (Sweden)

    Carlos Morcillo-Herrera

    2015-01-01

    Full Text Available This paper presents a practical method for calculating the electrical energy generated by a PV panel (kWhr through MATLAB simulations based on the mathematical model of the cell, which obtains the “Mean Maximum Power Point” (MMPP in the characteristic V-P curve, in response to evaluating historical climate data at specific location. This five-step method calculates through MMPP per day, per month, or per year, the power yield by unit area, then electrical energy generated by PV panel, and its real conversion efficiency. To validate the method, it was applied to Sewage Treatment Plant for a Group of Drinking Water and Sewerage of Yucatan (JAPAY, México, testing 250 Wp photovoltaic panels of five different manufacturers. As a result, the performance, the real conversion efficiency, and the electricity generated by five different PV panels in evaluation were obtained and show the best technical-economic option to develop the PV generation project.

  14. Quantitation of heparosan with heparin lyase III and spectrophotometry.

    Science.gov (United States)

    Huang, Haichan; Zhao, Yingying; Lv, Shencong; Zhong, Weihong; Zhang, Fuming; Linhardt, Robert J

    2014-02-15

    Heparosan is Escherichia coli K5 capsule polysaccharide, which is the key precursor for preparing bioengineered heparin. A rapid and effective quantitative method for detecting heparosan is important in the large-scale production of heparosan. Heparin lyase III (Hep III) effectively catalyzes the heparosan depolymerization, forming unsaturated disaccharides that are measurable using a spectrophotometer at 232 nm. We report a new method for the quantitative detection of heparosan with heparin lyase III and spectrophotometry that is safer and more specific than the traditional carbazole assay. In an optimized detection system, heparosan at a minimum concentration of 0.60 g/L in fermentation broth can be detected. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Device, system and method for a sensing electrical circuit

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2009-01-01

    The invention relates to a driven ground electrical circuit. A driven ground is a current-measuring ground termination to an electrical circuit with the current measured as a vector with amplification. The driven ground module may include an electric potential source V.sub.S driving an electric current through an impedance (load Z) to a driven ground. Voltage from the source V.sub.S excites the minus terminal of an operational amplifier inside the driven ground which, in turn, may react by generating an equal and opposite voltage to drive the net potential to approximately zero (effectively ground). A driven ground may also be a means of passing information via the current passing through one grounded circuit to another electronic circuit as input. It may ground one circuit, amplify the information carried in its current and pass this information on as input to the next circuit.

  16. In-situ electric field in human body model in different postures for wireless power transfer system in an electrical vehicle

    International Nuclear Information System (INIS)

    Shimamoto, Takuya; Laakso, Ilkka; Hirata, Akimasa

    2015-01-01

    The in-situ electric field of an adult male model in different postures is evaluated for exposure to the magnetic field leaked from a wireless power transfer system in an electrical vehicle. The transfer system is located below the centre of the vehicle body and the transferred power and frequency are 7 kW and 85 kHz, respectively. The in-situ electric field is evaluated for a human model (i) crouching near the vehicle, (ii) lying on the ground with or without his arm stretched, (iii) sitting in the driver’s seat, and (iv) standing on a transmitting coil without a receiving coil. In each scenario, the maximum in-situ electric fields are lower than the allowable limit prescribed by international guidelines, although the local magnetic field strength in regions of the human body is higher than the allowable external magnetic field strength. The highest in-situ electric field is observed when the human body model is placed on the ground with his arm extended toward the coils, because of a higher magnetic field around the arm. (paper)

  17. In-situ electric field in human body model in different postures for wireless power transfer system in an electrical vehicle.

    Science.gov (United States)

    Shimamoto, Takuya; Laakso, Ilkka; Hirata, Akimasa

    2015-01-07

    The in-situ electric field of an adult male model in different postures is evaluated for exposure to the magnetic field leaked from a wireless power transfer system in an electrical vehicle. The transfer system is located below the centre of the vehicle body and the transferred power and frequency are 7 kW and 85 kHz, respectively. The in-situ electric field is evaluated for a human model (i) crouching near the vehicle, (ii) lying on the ground with or without his arm stretched, (iii) sitting in the driver's seat, and (iv) standing on a transmitting coil without a receiving coil. In each scenario, the maximum in-situ electric fields are lower than the allowable limit prescribed by international guidelines, although the local magnetic field strength in regions of the human body is higher than the allowable external magnetic field strength. The highest in-situ electric field is observed when the human body model is placed on the ground with his arm extended toward the coils, because of a higher magnetic field around the arm.

  18. Separation method for ions of elements of the III., IV., VI. and VIII. groups of periodical system

    International Nuclear Information System (INIS)

    Marhol, M.

    1973-01-01

    The method is presented of separating the ions of the elements of the periodic system groups III, IV, and VIII by ion exchangers. The ions are complex-bonded to a new type of ion exchanger consisting of the polycondensates of phenol with aldehydes or ketones and containing an atom of phosphorus, arsenic or antimony with an atom of sulphur or oxygen in a complex bond. The polymers of compounds containing a double bond, e.g., of butadiene, polyvinyl alcohol, polyethylene, polypropylene, and the compounds of styrene with fural may also be used for this purpose. The method is demonstrated on a case of uranium and heavy metal concentration and the separation thereof from waste waters. (L.K.)

  19. Analysis of gold(I/III)-complexes by HPLC-ICP-MS demonstrates gold(III) stability in surface waters.

    Science.gov (United States)

    Ta, Christine; Reith, Frank; Brugger, Joël; Pring, Allan; Lenehan, Claire E

    2014-05-20

    Understanding the form in which gold is transported in surface- and groundwaters underpins our understanding of gold dispersion and (bio)geochemical cycling. Yet, to date, there are no direct techniques capable of identifying the oxidation state and complexation of gold in natural waters. We present a reversed phase ion-pairing HPLC-ICP-MS method for the separation and determination of aqueous gold(III)-chloro-hydroxyl, gold(III)-bromo-hydroxyl, gold(I)-thiosulfate, and gold(I)-cyanide complexes. Detection limits for the gold species range from 0.05 to 0.30 μg L(-1). The [Au(CN)2](-) gold cyanide complex was detected in five of six waters from tailings and adjacent monitoring bores of working gold mines. Contrary to thermodynamic predictions, evidence was obtained for the existence of Au(III)-complexes in circumneutral, hypersaline waters of a natural lake overlying a gold deposit in Western Australia. This first direct evidence for the existence and stability of Au(III)-complexes in natural surface waters suggests that Au(III)-complexes may be important for the transport and biogeochemical cycling of gold in surface environments. Overall, these results show that near-μg L(-1) enrichments of Au in environmental waters result from metastable ligands (e.g., CN(-)) as well as kinetically controlled redox processes leading to the stability of highly soluble Au(III)-complexes.

  20. Image Reconstruction Based on Homotopy Perturbation Inversion Method for Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2013-01-01

    Full Text Available The image reconstruction for electrical impedance tomography (EIT mathematically is a typed nonlinear ill-posed inverse problem. In this paper, a novel iteration regularization scheme based on the homotopy perturbation technique, namely, homotopy perturbation inversion method, is applied to investigate the EIT image reconstruction problem. To verify the feasibility and effectiveness, simulations of image reconstruction have been performed in terms of considering different locations, sizes, and numbers of the inclusions, as well as robustness to data noise. Numerical results indicate that this method can overcome the numerical instability and is robust to data noise in the EIT image reconstruction. Moreover, compared with the classical Landweber iteration method, our approach improves the convergence rate. The results are promising.

  1. UV and visible activation of Cr(III)-doped TiO2 catalyst prepared by a microwave-assisted sol-gel method during MCPA degradation.

    Science.gov (United States)

    Mendiola-Alvarez, S Y; Guzmán-Mar, J L; Turnes-Palomino, G; Maya-Alejandro, F; Hernández-Ramírez, A; Hinojosa-Reyes, L

    2017-05-01

    Photocatalytic degradation of 4-chloro-2-methylphenoxyacetic acid (MCPA) in aqueous solution using Cr(III)-doped TiO 2 under UV and visible light was investigated. The semiconductor material was synthesized by a microwave-assisted sol-gel method with Cr(III) doping contents of 0.02, 0.04, and 0.06 wt%. The catalyst was characterized using X-ray powder diffraction (XRD), scanning electron microscopy (SEM), nitrogen physisorption, UV-Vis diffuse reflectance spectroscopy (DRS), and atomic absorption spectroscopy (AAS). The photocatalytic activity for the photodegradation of MCPA was followed by reversed-phase high-performance liquid chromatography (HPLC) and total organic carbon (TOC) analysis. The intermediates formed during degradation were identified using gas chromatography-mass spectrometry (GC-MS). Chloride ion evolution was measured by ion chromatography. Characterization results showed that Cr(III)-doped TiO 2 materials possessed a small crystalline size, high surface area, and mesoporous structure. UV-Vis DRS showed enhanced absorption in the visible region as a function of the Cr(III) concentration. The Cr(III)-doped TiO 2 catalyst with 0.04 wt% of Cr(III) was more active than bare TiO 2 for the degradation of MCPA under both UV and visible light. The intermediates identified during MCPA degradation were 4-chloro-2-methylphenol (CMP), 2-(4-hydroxy-2-methylphenoxy) acetic acid (HMPA), and 2-hydroxybuta-1,3-diene-1,4-diyl-bis (oxy)dimethanol (HBDM); the formation of these intermediates depended on the radiation source.

  2. III-nitride integration on ferroelectric materials of lithium niobate by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Namkoong, Gon; Lee, Kyoung-Keun; Madison, Shannon M.; Henderson, Walter; Ralph, Stephen E.; Doolittle, W. Alan

    2005-01-01

    Integration of III-nitride electrical devices on the ferroelectric material lithium niobate (LiNbO 3 ) has been demonstrated. As a ferroelectric material, lithium niobate has a polarization which may provide excellent control of the polarity of III-nitrides. However, while high temperature, 1000 deg. C, thermal treatments produce atomically smooth surfaces, improving adhesion of GaN epitaxial layers on lithium niobate, repolarization of the substrate in local domains occurs. These effects result in multi domains of mixed polarization in LiNbO 3 , producing inversion domains in subsequent GaN epilayers. However, it is found that AlN buffer layers suppress inversion domains of III-nitrides. Therefore, two-dimensional electron gases in AlGaN/GaN heterojunction structures are obtained. Herein, the demonstration of the monolithic integration of high power devices with ferroelectric materials presents possibilities to control LiNbO 3 modulators on compact optoelectronic/electronic chips

  3. Heat loss and fluid leakage tests of the ROSA-III facility

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Shiba, Masayoshi

    1981-12-01

    The report presents characteristic test results about the steady state heat loss, one of the inherent characteristics of the ROSA-III test facility. The steady state heat loss tests were conducted at five different temperature conditions between 111 0 C and 290 0 C . Net heat loss rates were obtained by estimating the electric power supplied to the core, heat input from the recirculation pumps and steam leakage rate. The heat loss characteristics have important contribution to analyses of the ROSA-III small break tests. A following simple relation was obtained between the net heat loss rate Q*sub(HL) (kJ/s) (*: radical) of the ROSA-III facility and the temperature difference ΔT ( 0 C) between the fluid temperature of the system and the room temperature, Q*sub(HL) = 0.56 x ΔT. (*: radical) And the steam leak flow at normal operating condition of the ROSA-III test, (P = 7.2 MPa) was obtained as 8.9 x 10 -3 kg/s and corresponding steam leakage energy as 10.5 kJ/s. The heat input from the recirculation pumps was indirectly estimated under a constant speed by assuming the heat input was equal to the brake horce power of the pumps. (author)

  4. How to increase the efficiency of the electrical discharge method for destruction of nonconductive solid materials

    Energy Technology Data Exchange (ETDEWEB)

    Voitenko, N. V., E-mail: tevn@hvd.tpu.ru; Yudin, A. S.; Kuznetsova, N. S. [National Research Tomsk Polytechnic University (Russian Federation); Krastelev, E. G. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2016-12-15

    The paper deals with the relevance of using electrical discharge technology for construction works in the city. The technical capabilities of the installation for the multi-borehole electro-discharge splitting off and destruction of rocks and concrete are described. The ways to increase the efficiency of the electrical discharge method for the destruction of solids are proposed. In order to augment the discharge circuit energy, the energy storage is separated into two individual capacitor batteries. The throttle with the inductance of 28.6 μH is installed in one of the batteries, which increases the duration of the channel energy release to 400 μs and the efficiency of electrical discharge splitting off of concrete.

  5. Imaging assessment of isolated lesions affecting cranial nerve III; Avaliacao por imagem das lesoes isoladas do III par craniano

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Marcelo de Mattos [Colegio Brasileiro de Radiologia e Diagnostico por Imagem (CBR), Sao Paulo, SP (Brazil)]. E-mail: cidbh@cidbh.com.br; Martins, Jose Carlos Tadeu [Sociedade Brasileira de Neuroradiologia, Sao Paulo, SP (Brazil)

    2005-05-15

    The aim of this study is to review the anatomy and main pathologic conditions affecting cranial nerve III using imaging studies, particularly magnetic resonance imaging. Imaging methods are essential in the evaluation of patients with suspected lesions of the oculomotor nerve once signs and symptoms are unspecific and a large number of diseases can affect cranial nerve III. A brief review of the literature is also presented. (author)

  6. Method and Mechanisms of Soil Stabilization Using Electric Arc Furnace Dust

    OpenAIRE

    Al-Amoudi, Omar S. Baghabra; Al-Homidy, Abdullah A.; Maslehuddin, Mohammed; Saleh, Tawfik A.

    2017-01-01

    This paper reports the method and mechanism for improving the strength of marl and desert sand utilizing electric arc furnace dust (EAFD), an industrial by-product, in lieu of cement or lime. EAFD was used in conjunction with a small quantity (2%) of cement. The mechanical properties and durability characteristics of marl and sand mixed with 2% cement plus 5-, 10-, 20- or 30%-EAFD, by weight of the soil, were evaluated. The soil-cement-EAFD mixtures were used to determine their unconfined com...

  7. Spectroscopic investigations on the complexation of Cm(III) and Eu(III) with organic model ligands and their binding mode in human urine (in vitro); Spektroskopische Untersuchungen zur Komplexbildung von Cm(III) und Eu(III) mit organischen Modellliganden sowie ihrer chemischen Bindungsform in menschlichem Urin (in vitro)

    Energy Technology Data Exchange (ETDEWEB)

    Heller, Anne

    2011-10-26

    In case of incorporation, trivalent actinides (An(III)) and lanthanides (Ln(III)) pose a serious health risk to humans. An(III) are artificial, highly radioactive elements which are mainly produced during the nuclear fuel cycle in nuclear power plants. Via hazardous accidents or nonprofessional storage of radioactive waste, they can be released in the environment and enter the human food chain. In contrast, Ln(III) are nonradioactive, naturally occurring elements with multiple applications in technique and medicine. Consequently it is possible that humans get in contact and incorporate both, An(III) and Ln(III). Therefore, it is of particular importance to elucidate the behaviour of these elements in the human body. While macroscopic processes such as distribution, accumulation and excretion are studied quite well, knowledge about the chemical binding form (speciation) of An(III) and Ln(III) in various body fluids is still sparse. In the present work, for the first time, the speciation of Cm(III) and Eu(III) in natural human urine (in vitro) has been investigated spectroscopically and the formed complex identified. For this purpose, also basic investigations on the complex formation of Cm(III) and Eu(III) in synthetic model urine as well as with the urinary relevant, organic model ligands urea, alanine, phenylalanine, threonine and citrate have been performed and the previously unknown complex stability constants determined. Finally, all experimental results were compared to literature data and predictions calculated by thermodynamic modelling. Since both, Cm(III) and Eu(III), exhibit unique luminescence properties, particularly the suitability of time-resolved laser-induced fluorescence spectroscopy (TRLFS) could be demonstrated as a method to investigate these metal ions in untreated, complex biofluids. The results of this work provide new scientific findings on the biochemical reactions of An(III) and Ln(III) in human body fluids on a molecular scale and

  8. Optimal Planning Method of On-load Capacity Regulating Distribution Transformers in Urban Distribution Networks after Electric Energy Replacement Considering Uncertainties

    Directory of Open Access Journals (Sweden)

    Yu Su

    2018-06-01

    Full Text Available Electric energy replacement is the umbrella term for the use of electric energy to replace oil (e.g., electric automobiles, coal (e.g., electric heating, and gas (e.g., electric cooking appliances, which increases the electrical load peak, causing greater valley/peak differences. On-load capacity regulating distribution transformers have been used to deal with loads with great valley/peak differences, so reasonably replacing conventional distribution transformers with on-load capacity regulating distribution transformers can effectively cope with load changes after electric energy replacement and reduce the no-load losses of distribution transformers. Before planning for on-load capacity regulating distribution transformers, the nodal effective load considering uncertainties within the life cycle after electric energy replacement was obtained by a Monte Carlo method. Then, according to the loss relation between on-load capacity regulating distribution transformers and conventional distribution transformers, three characteristic indexes of annual continuous apparent power curve and replacement criteria for on-load capacity regulating distribution transformers were put forward in this paper, and a set of distribution transformer replaceable points was obtained. Next, based on cost benefit analysis, a planning model of on-load capacity regulating distribution transformers which consists of investment profitability index within the life cycle, investment cost recouping index and capacity regulating cost index was put forward. The branch and bound method was used to solve the planning model within replaceable point set to obtain upgrading and reconstruction scheme of distribution transformers under a certain investment. Finally, planning analysis of on-load capacity regulating distribution transformers was carried out for electric energy replacement points in one urban distribution network under three scenes: certain load, uncertain load and nodal

  9. The latest electrical installation (I)

    International Nuclear Information System (INIS)

    Won, Jong Su

    1976-04-01

    This book deals with the latest electrical installation. The contents of this book are construction electrical installation, regulations related electrical installation, foundation and principle of wiring, main line feeder, lighting installation, power of wiring, main line feeder, lighting installation, power installation, method to read structure drawing for electrical construct drawing electric lamp wiring diagram, working drawing, material and tools and method of construction of electrical installation on types of wiring construction, metallic conduit, rigid poly-vinyl conduit wiring, bus duct work, cable work and insulation out of metal lathed.

  10. On the electricity shortage, price and electricity theft nexus

    International Nuclear Information System (INIS)

    Jamil, Faisal

    2013-01-01

    Pakistan is facing severe electricity shortfall of its history since 2006. Several measures have been implemented in order to mitigate electricity shortage. The focus has been on raising the installed capacity of electricity generation and transmission. The present policy results in expensive thermal electricity generation mostly using expensive and environmentally hazardous furnace oil and inability of utilities to recover their cost of supply although there is unprecedented rise in electricity tariffs. This study concentrates on the electricity demand and traces the relationship between electricity shortfalls, tariff rate and electricity theft in the background of recent electricity crisis using the data for the period 1985–2010. We employed the Granger causality test through error correction model and out-of-sample causality through variance decomposition method. Empirical evidence shows that electricity theft greatly influences electricity shortfalls through lowering investment and inefficient use of electricity. The study concludes that electricity crisis cannot be handled without combating rampant electricity theft in the country. - Highlights: ► The study investigates relationship among electricity outages, price and electricity theft. ► It employed Johansen approach, ECM and variance decomposition analysis. ► Empirical evidence shows that electricity theft causes outages and rising tariff rates. ► Variance decomposition analysis results are slightly different from ECM

  11. Use of the piezoelectric film for the determination of cracks and defects - the passive and active electric potential CT method

    International Nuclear Information System (INIS)

    Kubo, S; Sakagami, T; Suzuki, T; Maeda, T; Nakatani, K

    2008-01-01

    The passive and active electric potential CT method was proposed by using piezoelectric film for identification of cracks and defects. This method is based on the principle of mutual conversion between mechanical strains and electric potential of piezoelectric material. A smart-layer was constructed using the piezoelectric film, and attached on a structure with a defect. When the structure was subjected to a mechanical load, the electric potential distribution appeared passively on the piezoelectric film due to the direct piezoelectric effect. The defect can be identified from the distribution with the help of inverse analysis. It was found that the crack could be identified reasonably, although the defect depth was not well estimated for the defects located far from the layer. When the electric signal was input to the smart-layer, acoustic wave was actively emitted from the layer due to the inverse piezoelectric effect, and a reflected wave was received on the layer. It was found that the depth of the defect could be estimated well. The simultaneous use of the passive method and the active method is promising for the identification of the defect.

  12. Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10. Final report

    International Nuclear Information System (INIS)

    Fields, M.B.; Kudrick, J.A.

    1984-08-01

    This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases and conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff approved acceptance criteria for LOCA-related hydrodynamic loads are provided in an appendix

  13. A Practical Torque Estimation Method for Interior Permanent Magnet Synchronous Machine in Electric Vehicles.

    Science.gov (United States)

    Wu, Zhihong; Lu, Ke; Zhu, Yuan

    2015-01-01

    The torque output accuracy of the IPMSM in electric vehicles using a state of the art MTPA strategy highly depends on the accuracy of machine parameters, thus, a torque estimation method is necessary for the safety of the vehicle. In this paper, a torque estimation method based on flux estimator with a modified low pass filter is presented. Moreover, by taking into account the non-ideal characteristic of the inverter, the torque estimation accuracy is improved significantly. The effectiveness of the proposed method is demonstrated through MATLAB/Simulink simulation and experiment.

  14. Electrically conductive, black thermal control coatings for spacecraft applications. III - Plasma-deposited ceramic matrix

    Science.gov (United States)

    Hribar, V. F.; Bauer, J. L.; O'Donnell, T. P.

    1987-01-01

    Five black, electrically-conductive thermal control coatings have been formulated and tested for application on the Galileo spacecraft. The coatings consist of both organic and inorganic systems applied on titanium, aluminum, and glass/epoxy composite surfaces. The coatings were tested under simulated space environment conditions. Coated specimens were subjected to thermal radiation, convective and combustive heating, and cryogenic conditions over a temperature range between -196 C and 538 C. Mechanical, physical, thermal, electrical, and thermooptical properties are presented for one of these coatings. This paper describes the preparation, characteristics, and spraying of iron titanate on titanium and aluminum, and presents performance results.

  15. Study of methods for electrical modification of a clay suspension

    Energy Technology Data Exchange (ETDEWEB)

    Karimov, R A; Kudaktina, T T; Parpiyev, T R

    1982-01-01

    As a result of the conducted experiments it was established that the viscosity and maximum static shear stress of the drilling muds prepared on electrically treated water increases 2-3-fold as compared to the muds prepared on standard water. This is explained by the fact that the unipolar treatment results in deep change in the water structure. Under the influence of the electrical current, there is activation, rise in the electrical conductivity, decrease in surface tension, considerable rise in the pH value, etc. The output of clay mud increases 1.5-fold in the clay suspension that is prepared on electrically treated water.

  16. Synthesis and characterization of La(III), Pr(III), Nd(III), Sm(III), Eu(III), Gd(III), Tb(III) and Dy(III) complexes of 2-acetylfuran-2-thenoylhydrazone

    International Nuclear Information System (INIS)

    Singh, B.; Singh, Praveen K.

    1998-01-01

    The reaction of 2-acetylfuran-2-thenoylhydrazone(afth) with Ln(III) trichlorides yields complexes of the type [Ln(afth)Cl 2 (H 2 O)(EtOH)]Cl, [Ln(III) = La, Pr, Nd, Sm, Eu, Gd, Tb and Dy]. The complexes have been characterized by molar conductance, magnetic susceptibility and TGA and DTA measurements, magnetic susceptibility and TGA and DTA measurements, FAB mass, infrared, proton NMR, electronic absorption and emission spectra. The terbium complex is found to be monomer from the FAB mass spectrum. The IR and NMR spectra suggest neutral tridentate behaviour of the Schiff base. A coordination number seven is proposed around the metal ions. Emission spectra suggest C 3v , symmetry around the metal ion with capped octahedron geometry for the europium complex. (author)

  17. Electrical characterization of TiO2 nanotubes synthesized through electrochemical anodizing method

    Science.gov (United States)

    Manescu Paltanea, Veronica; Paltanea, Gheorghe; Popovici, Dorina; Jiga, Gabriel

    2016-05-01

    In the present paper, the electrochemical anodizing method was used for the obtaining of TiO2 nanotube layers, developed on titanium surface. Self-organized titanium nanotubes were obtained when an aqueous solution of 49.5 wt % H2O - 49.5 wt % glycerol - 1 wt % HF was used as electrolyte, the anodizing time being equal to 8 hours and the applied voltage to 25 V. Scanning electron microscopy shows that the one-dimensional nanostructure has a tubular configuration with an inner diameter of approximately 60 nm and an outer diameter of approximately 100 nm. The electrical properties of these materials were analyzed through dielectric spectroscopy method.

  18. Examination on the testing method for evaluating life of electric wires and cables for nuclear reactors

    International Nuclear Information System (INIS)

    Seguchi, Tadao; Morita, Yosuke; Yoshida, Kenzo

    1984-01-01

    Regarding the method of environmental test on the electric wires and cables used for the safety system in the containment vessels of nuclear power plants, the draft recommendation was issued by the Institute of Electrical Engineers of Japan in 1982. Its contents follow the IEEE Standard of USA, and are composed of the tests on the deterioration in normal operation, the case of LOCA and the prevention of spread of fire. In this report, as to the testing method regarding normal operation, the appropriate method and its basis are described in view of the recent experimental data. In the draft recommendation, the successive method carrying out irradiation after thermal deterioration is adopted, and both testing conditions are given. However, the fundamental problems remain in the propriety of the acceleration of deterioration and the multiplied effect of heat and radiation. The qualitative and quantitative data on these problems have been accumulated in various countries, therefore, the examination of the testing method was carried out based on these data. The dose rate dependence of radiation deterioration, the multiplied effect of radiation and heat, and the correlation of thermal deterioration rate with temperature are discussed. The appropriate method is proposed. (Kako, I.)

  19. Development of friction welding method by electric servo motors; Dendo servo shiki masatsu assetsuho no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, H; Onuma, M; Hasegawa, T; Sakamoto, T [Toyota Motor Corp., Aichi (Japan)

    1997-10-01

    The standard friction welding has two methods; the brake method and the inertia method. We have developed a new friction welding method with the electric servo motor system. The forming of plastic fluidity layers of interface is evaluated quantitatively with the feedback control characteristics. The new method has enabled to reduce the heat effect and the burr of friction welding. In the method, we could reduce the getting heat energy, from one-third to half less than the previous methods. 6 refs., 16 figs.

  20. Method to grow group III-nitrides on copper using passivation layers

    Science.gov (United States)

    Li, Qiming; Wang, George T; Figiel, Jeffrey T

    2014-06-03

    Group III-nitride epilayers can be grown directly on copper substrates using intermediate passivation layers. For example, single crystalline c-plane GaN can be grown on Cu (110) substrates with MOCVD. The growth relies on a low temperature AlN passivation layer to isolate any alloying reaction between Ga and Cu.

  1. Preparation and characterisation of mixed ligand complexes of Co(III), Fe(III) and Cr(III) containing phthalimide and phenols

    International Nuclear Information System (INIS)

    Miah, M.A.J.; Islam, M.S.; Pal, S.C.; Barma, T.K.

    1996-01-01

    Some novel mixed ligand complexes of Co(III), Fe(III) and Cr(III) containing phthalimide as primary and 2-aminophenol and 3-aminophenol as secondary ligands have been synthesized and characterised on the basis of elemental analyses, conductivity and magnetic measurements and infrared and electronic spectral studies. Complexes containing 2-aminophenol are 1:1 electrolyte in N,N dimethylformamide. Spectral studies indicate that all the complexes exhibit octahedral geometry. The complexes have the general composition; K[M(pim)/sub 2/(L)/sub 2/]; where m=Co(III), Fe(III) and Cr(III), pim-anion of phthalimamide and L=anion of 2-aminophenol and 3-aminophenol. (author)

  2. Rethinking ASME III seismic analysis for piping operability evaluations

    International Nuclear Information System (INIS)

    Adams, T.M.; Stevenson, J.D.

    1994-01-01

    It has been recognized since the mid 1980's that there are very large seismic margins to failure for nuclear piping systems when designed using current industry practice, design criteria, and methods. As a result of this realization there are or have been approximately eighteen initiatives within the ASME , Boiler and Pressure Vessel Code Section III, Division 1, in the form of proposed code cases and proposed code text changes designed to reduce these failure margins to more realistic values. For the most part these initiatives have concentrated on reclassifying seismic inertia stresses in the piping as secondary and increasing the allowable stress limits permitted by Section III of the ASME, Boiler Code. This paper focuses on the application of non-linear spectral analysis methods as a method to reduce the input seismic demand determination and thereby reduce the seismic failure margins. The approach is evaluated using the ASME Boiler Pressure Vessel Code Section III Subgroup on Design benchmark procedure as proposed by the Subgroup's Special Task Group on Integrated Piping Criteria. Using this procedure, criteria are compared to current code criterion and analysis methods, and several other of the currently proposed Boiler and Pressure Vessel, Section III, changes. Finally, the applicability of the non-linear spectral analysis to continued Safe Operation Evaluations is reviewed and discussed

  3. Atmospheric electricity

    CERN Document Server

    Chalmers, J Alan

    1957-01-01

    Atmospheric Electricity brings together numerous studies on various aspects of atmospheric electricity. This book is composed of 13 chapters that cover the main problems in the field, including the maintenance of the negative charge on the earth and the origin of the charges in thunderstorms. After a brief overview of the historical developments of atmospheric electricity, this book goes on dealing with the general principles, results, methods, and the MKS system of the field. The succeeding chapters are devoted to some aspects of electricity in the atmosphere, such as the occurrence and d

  4. One of the possible mechanisms for the inhibition effect of Tb(III) on peroxidase activity in horseradish (Armoracia rusticana) treated with Tb(III).

    Science.gov (United States)

    Guo, Shaofen; Cao, Rui; Lu, Aihua; Zhou, Qing; Lu, Tianhong; Ding, Xiaolan; Li, Chaojun; Huang, Xiaohua

    2008-05-01

    One of the possible mechanisms for the inhibition effect of Tb(III) on peroxidase activity in horseradish (Armoracia rusticana) treated with Tb(III) was investigated using some biophysical and biochemical methods. Firstly, it was found that a large amount of Tb(III) can be distributed on the cell wall, that some Tb(III) can enter into the horseradish cell, indicating that peroxidase was mainly distributed on cell wall, and thus that Tb(III) would interact with horseradish peroxidase (HRP) in the plant. In addition, peroxidase bioactivity was decreased in the presence of Tb(III). Secondly, a new peroxidase-containing Tb(III) complex (Tb-HRP) was obtained from horseradish after treatment with Tb(III); the molecular mass of Tb-HRP is near 44 kDa and the pI is about 8.80. Thirdly, the electrocatalytic activity of Tb-HRP is much lower than that of HRP obtained from horseradish without treatment with Tb(III). The decrease in the activity of Tb-HRP is due to the destruction (unfolding) of the conformation in Tb-HRP. The planarity of the heme active center in the Tb-HRP molecule was increased and the extent of exposure of Fe(III) in heme was decreased, leading to inhibition of the electron transfer. The microstructure change in Tb-HRP might be the result of the inhibition effect of Tb(III) on peroxidase activity in horseradish.

  5. Method and system for operating an electric motor

    Science.gov (United States)

    Gallegos-Lopez, Gabriel; Hiti, Silva; Perisic, Milun

    2013-01-22

    Methods and systems for operating an electric motor having a plurality of windings with an inverter having a plurality of switches coupled to a voltage source are provided. A first plurality of switching vectors is applied to the plurality of switches. The first plurality of switching vectors includes a first ratio of first magnitude switching vectors to second magnitude switching vectors. A direct current (DC) current associated with the voltage source is monitored during the applying of the first plurality of switching vectors to the plurality of switches. A second ratio of the first magnitude switching vectors to the second magnitude switching vectors is selected based on the monitoring of the DC current associated with the voltage source. A second plurality of switching vectors is applied to the plurality of switches. The second plurality of switching vectors includes the second ratio of the first magnitude switching vectors to the second magnitude switching vectors.

  6. Electrical investigations of hybrid OLED microcavity structures with novel encapsulation methods

    Science.gov (United States)

    Meister, Stefan; Brückner, Robert; Fröb, Hartmut; Leo, Karl

    2016-04-01

    An electrical driven organic solid state laser is a very challenging goal which is so far well beyond reach. As a step towards realization, we monolithically implemented an Organic Light Emitting Diode (OLED) into a dielectric, high quality microcavity (MC) consisting of two Distributed Bragg Reectors (DBR). In order to account for an optimal optical operation, the OLED structure has to be adapted. Furthermore, we aim to excite the device not only electrically but optically as well. Different OLED structures with an emission layer consisting of Alq3:DCM (2 wt%) were investigated. The External Quantum Efficiencies (EQE) of this hybrid structures are in the range of 1-2 %, as expected for this material combination. Including metal layers into a MC is complicated and has a huge impact on the device performance. Using Transfer-Matrix-Algorithm (TMA) simulations, the best positions for the metal electrodes are determined. First, the electroluminescence (EL) of the adjusted OLED structure on top of a DBR is measured under nitrogen atmosphere. The modes showed quality factors of Q = 60. After the deposition of the top DBR, the EL is measured again and the quality factors increased up to Q = 600. Considering the two 25-nm-thick-silver contacts a Q-factor of 600 is very high. The realization of a suitable encapsulation method is important. Two approaches were successfully tested. The first method is based on the substitution of a DBR layer with a layer produced via Atomic Layer Deposition (ALD). The second method uses a 0.15-mm-thick cover glass glued on top of the DBR with a 0.23-μm-thick single-component glue layer. Due to the working encapsulation, it is possible to investigate the sample under ambient conditions.

  7. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  8. The Use of Electrical Resistivity Method to Mapping The Migration of Heavy Metals by Electrokinetic

    Science.gov (United States)

    Azhar, A. T. S.; Ayuni, S. A.; Ezree, A. M.; Nizam, Z. M.; Aziman, M.; Hazreek, Z. A. M.; Norshuhaila, M. S.; Zaidi, E.

    2017-08-01

    The presence of heavy metals contamination in soil environment highly needs innovative remediation. Basically, this contamination was resulted from ex-mining sites, motor workshop, petrol station, landfill and industrial sites. Therefore, soil treatment is very important due to metal ions are characterized as non-biodegradable material that may be harmful to ecological system, food chain, human health and groundwater sources. There are various techniques that have been proposed to eliminate the heavy metal contamination from the soil such as bioremediation, phytoremediation, electrokinetic remediation, solidification and stabilization. The selection of treatment needs to fulfill some criteria such as cost-effective, easy to apply, green approach and high remediation efficiency. Electrokinetic remediation technique (EKR) offers those solutions in certain area where other methods are impractical. While, electrical resistivity method offers an alternative geophysical technique for soil subsurface profiling to mapping the heavy metals migration by the influece of electrical gradient. Consequently, this paper presents an overview of the use of EKR to treat contaminated soil by using ERM method to verify their effectiveness to remove heavy metals.

  9. Applying reliability analysis to design electric power systems for More-electric aircraft

    Science.gov (United States)

    Zhang, Baozhu

    The More-Electric Aircraft (MEA) is a type of aircraft that replaces conventional hydraulic and pneumatic systems with electrically powered components. These changes have significantly challenged the aircraft electric power system design. This thesis investigates how reliability analysis can be applied to automatically generate system topologies for the MEA electric power system. We first use a traditional method of reliability block diagrams to analyze the reliability level on different system topologies. We next propose a new methodology in which system topologies, constrained by a set reliability level, are automatically generated. The path-set method is used for analysis. Finally, we interface these sets of system topologies with control synthesis tools to automatically create correct-by-construction control logic for the electric power system.

  10. Exploration of a new method in determining the glass transition temperature of BMGs by electrical resistivity

    Science.gov (United States)

    Guo, Jing; Zu, Fangqiu; Chen, Zhihao; Zheng, Shubin; Yuan, Yuan

    2005-07-01

    Based on a brief retrospect of the method in establishing Tg of the bulk metallic glasses (BMGs), some perplexities concerning this are pointed out. With the experimental results of Zr-Al-Ni-Cu-X (Nb,Ti) BMGs, a electrical resistivity method is proposed to determine the glass transition temperature of BMGs. With the method, we define two kinds of characteristic temperature related to the glass transition, Tg-dep and Tg-int, respectively. By comparing Tg-dep and Tg-int with Tg determined by the DSC method, we have found that, for the same alloy at the same heating rate, Tg-dep is very close to Tg-onset while Tg-int is approximate to Tg-mid. As a method to determine the glass transition temperature, the electrical resistivity method has proved to be more convenient and practical in comparison with the DSC method, especially when the DSC curve cannot show the glass transition character of BMGs. In addition, we would emphasize that when we refer to Tg, it is necessary to expatiate on the way of denoting the glass transition temperature, such as Tg-dep or Tg-int ( Tg-onset or Tg-mid), and on the heating rate, in order to avoid ambiguity.

  11. Reversed phase partition chromatographic separation of Gd(III) on poly(Crown Ether) column

    International Nuclear Information System (INIS)

    Mahanwar, K.R.; Sabale, S.R.

    2014-01-01

    A simple method has been developed for the separation of Gd(III) in hippuric acid medium by using poly(dibenzo-18-crown-6) as stationary phase. The effect of hippuric acid concentration, different eluting agent, foreign ions etc was studied and the optimum conditions were established. Breakthrough capacity of poly(dibenzo-18-crown-6) for Gd(III) was found to be 0.572 ±0.01 mmolg -1 of crown polymer. The separation of Gd(III) from other elements in multicomponent mixtures has been achieved. The method was extended for determination of Gd(III) in real sample. The method is simple, rapid and selective with good reproducibility (approximately ± 2%). Crown ethers are widely used as complexing agent that can selectively capture metal cation in their cavity. This special feature shown by poly (dibenzo-18-crown-6) has been used in our laboratory for selective cation exchanger by column chromatography. No attempts were made for the separation of Gd(III) using hippuric acid media and column chromatography. The present communication describes a simple and sensitive method for the determination of Gd(III) using poly(dibenzo-18-crown-6) as stationary phase in hippuric acid medium. The proposed method affords an attractive feature as compared to the solvent extraction technique i.e. it is free from any organic diluents as an environmental concern

  12. Performance Evaluation of Sub-manufacturing Sectors Using TOPSIS and ELECTRE Methods

    Directory of Open Access Journals (Sweden)

    Nuri ÖMÜRBEK

    2014-06-01

    Full Text Available Performance analysis is defined as a process of collecting, analyzing and reporting data systematically and regularly for a business to monitor its sources it has used, products and services it has produced, and the results it gained. For operators, it means quantitative expression of actions which are performed by a business or maintained in a program. In this study, financial performances of manufacture sectors are analyzed by the methods of TOPSIS and ELECTRE using current ratio, cash ratio, total debt / total assets, inventory turnover rate, equity turnover rate, net profit / equity, operating ıncome /net sales, net profit / sales and cost of good sold / net sales criteria. The findings suggest that coal and refined petroleum product manufacturing industry is in the first place in both methods.

  13. Factors affecting stress distribution and displacements in crystals III-V grown by Czochralski method with liquid encapsulation

    International Nuclear Information System (INIS)

    Schvezov, C.E.; Samarasekera, I.; Weinberg, F.

    1988-01-01

    A mathematical model based on the finite element method for calculating temperature and shear stress distributions in III-V crystals grown by LEC technique was developed. The calculated temperature are in good agreements with the experimental measurements. The shear stress distribution was calculated for several environmental conditions. The results showed that the magnitude and the distribution of shear stresses are highly sensitive to the crystal environment, including thickness and temperature distribution in boron oxides and the gas. The shear stress is also strongly influenced by interface curvature and cystals radius. (author) [pt

  14. Electrical and optical properties of CZTS thin films prepared by SILAR method

    Directory of Open Access Journals (Sweden)

    J. Henry

    2016-03-01

    Full Text Available In the present work, Cu2ZnSnS4 (CZTS thin film was deposited onto the glass substrate by simple and economic SILAR method and its structural, morphological, optical and electrical properties were analyzed. X-ray diffraction (XRD analysis confirms the formation of CZTS with kesterite structure and the average crystallite size is found to be 142 nm. Scanning electron microscope (SEM image shows that the film has homogeneous, agglomerated surface without any cracks. The prepared CZTS film shows good optical absorption (104 cm−1 in the visible region and the optical band gap energy is found to be quite close to the optimum value of about 1.54 eV for solar cell application. The refractive index of the prepared film is found to be 2.85. The electrical resistivity of the film is found to be ∼10−2 Ω cm at room temperature.

  15. The Mexican electricity industry - cogeneration potential

    International Nuclear Information System (INIS)

    Monroy, I.L.

    2000-01-01

    A brief history of Mexico's electric power industry is given. Diagrams show (i) the increase in primary energy production from 1990-1998; (ii) energy consumption by sector and (iii) the change in capacity between 1990 and 1998. The projected energy development for 1998-2007 is discussed. The Mexican government has chosen cogeneration to be an important contributor to future energy-efficient power production. Data on installed cogeneration capacity for years 2000 and 2001 are given according to sector

  16. Methods for the improvement of electrical insulation in vacuum in the presence of transverse magnetic field

    International Nuclear Information System (INIS)

    Hara, Masanori; Suehiro, Junya; Shigematsu, Hidetaka; Yano, Shinsuke

    1989-01-01

    At present in electrical energy field, aiming at the development and operation of new energy sources for the future, the research on nuclear fusion reactors, MHD electricity generation, and electromagnetic energy storage is in progress, and in ordeer to form strong magnetic fields over wide space, large superconducting magnets are expected to be employed. In these magnets, when exciting current changes, voltage is induced internally, therefore, the operation sequence is deeply related to coil insulation, in pulse operation, coil insulation is one of the important factors determining the rating, and the withstand voltage design against the abnormal voltage at the time of quenching is related to the protection of coils. Therefore, the electrical insulation design of large superconducting magnets is an important subject of study. Their electrical insulation system is the compound system of liquid helium, gaseous helium, vacuum and solid insulators. When a cross magnetic field is applied, insulation breakdown characteristics are aggravated. The mechanism of vacuum insulation breakdown and characteristics, the method of improving withstand voltage using spacers or the electrodes for controlling electric field and so on are reported. (K.I.)

  17. Vibration Prediction Method of Electric Machines by using Experimental Transfer Function and Magnetostatic Finite Element Analysis

    International Nuclear Information System (INIS)

    Saito, A; Kuroishi, M; Nakai, H

    2016-01-01

    This paper concerns the noise and structural vibration caused by rotating electric machines. Special attention is given to the magnetic-force induced vibration response of interior-permanent magnet machines. In general, to accurately predict and control the vibration response caused by the electric machines, it is inevitable to model not only the magnetic force induced by the fluctuation of magnetic fields, but also the structural dynamic characteristics of the electric machines and surrounding structural components. However, due to complicated boundary conditions and material properties of the components, such as laminated magnetic cores and varnished windings, it has been a challenge to compute accurate vibration response caused by the electric machines even after their physical models are available. In this paper, we propose a highly-accurate vibration prediction method that couples experimentally-obtained discrete structural transfer functions and numerically-obtained distributed magnetic-forces. The proposed vibration synthesis methodology has been applied to predict vibration responses of an interior permanent magnet machine. The results show that the predicted vibration response of the electric machine agrees very well with the measured vibration response for several load conditions, for wide frequency ranges. (paper)

  18. Study of electric capacitors using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Alina Neamț

    2012-12-01

    Full Text Available A capacitor is made of two armatures and a dielectric between the two armatures. In this paper, we are going to study the plane capacitor , which is made of two equal metal armatures, plane and parallel, having the S surface, situated at a distance d much shorter than the armatures dimensions, between which there is a liniar, homogenous and isotropic dielectric having a constant electrical permittivity.The purpose of studying the plane capacitor, through MEF, presented in this paper,is to establish the stress to which the dielectrics may be subject to, in daily practice, and the influence that their superposition in an electric field has, on each of them. The study of the plane capacitor , finalised with observations on the raise of the dependence of the electric field intensity in air on the size of the air layer and having as parameter the type of dielectric material introduced between the armatures, is an example of confirmation or invalidation of the possibility and utility of using layers of dielectrics between the armatures of the capacitors.

  19. Ideology of a multiparametric system for estimating the insulation system of electric machines on the basis of absorption testing methods

    Science.gov (United States)

    Kislyakov, M. A.; Chernov, V. A.; Maksimkin, V. L.; Bozhin, Yu. M.

    2017-12-01

    The article deals with modern methods of monitoring the state and predicting the life of electric machines. In 50% of the cases of failure in the performance of electric machines is associated with insulation damage. As promising, nondestructive methods of control, methods based on the investigation of the processes of polarization occurring in insulating materials are proposed. To improve the accuracy of determining the state of insulation, a multiparametric approach is considered, which is a basis for the development of an expert system for estimating the state of health.

  20. Analysis of excess reactivity of JOYO MK-III performance test core

    International Nuclear Information System (INIS)

    Maeda, Shigetaka; Yokoyama, Kenji

    2003-10-01

    JOYO is currently being upgraded to the high performance irradiation bed JOYO MK-III core'. The MK-III core is divided into two fuel regions with different plutonium contents. To obtain a higher neutron flux, the active core height was reduced from 55 cm to 50 cm. The reflector subassemblies were replaced by shielding subassemblies in the outer two rows. Twenty of the MK-III outer core fuel subassemblies in the performance test core were partially burned in the transition core. Four irradiation test rigs, which do not contain any fuel material, were loaded in the center of the performance test core. In order to evaluate the excess reactivity of MK-III performance test core accurately, we evaluated it by applying not only the JOYO MK-II core management code system MAGI, but also the MK-III core management code system HESTIA, the JUPITER standard analysis method and the Monte Carlo method with JFS-3-J3.2R content set. The excess reactivity evaluations obtained by the JUPITER standard analysis method were corrected to results based on transport theory with zero mesh-size in space and angle. A bias factor based on the MK-II 35th core, which sensitivity was similar to MK-III performance test core's, was also applied, except in the case where an adjusted nuclear cross-section library was used. Exact three-dimensional, pin-by-pin geometry and continuous-energy cross sections were used in the Monte Carlo calculation. The estimated error components associated with cross-sections, methods correction factors and the bias factor were combined based on Takeda's theory. Those independently calculated values agree well and range from 2.8 to 3.4%Δk/kk'. The calculation result of the MK-III core management code system HESTLA was 3.13% Δk/kk'. The estimated errors for bias method range from 0.1 to 0.2%Δk/kk'. The error in the case using adjusted cross-section was 0.3%Δk/kk'. (author)

  1. Classification of criticality calculations with correlation coefficient method and its application to OECD/NEA burnup credit benchmarks phase III-A and II-A

    International Nuclear Information System (INIS)

    Okuno, Hiroshi

    2003-01-01

    A method for classifying benchmark results of criticality calculations according to similarity was proposed in this paper. After formulation of the method utilizing correlation coefficients, it was applied to burnup credit criticality benchmarks Phase III-A and II-A, which were conducted by the Expert Group on Burnup Credit Criticality Safety under auspices of the Nuclear Energy Agency of the Organisation for Economic Cooperation and Development (OECD/NEA). Phase III-A benchmark was a series of criticality calculations for irradiated Boiling Water Reactor (BWR) fuel assemblies, whereas Phase II-A benchmark was a suite of criticality calculations for irradiated Pressurized Water Reactor (PWR) fuel pins. These benchmark problems and their results were summarized. The correlation coefficients were calculated and sets of benchmark calculation results were classified according to the criterion that the values of the correlation coefficients were no less than 0.15 for Phase III-A and 0.10 for Phase II-A benchmarks. When a couple of benchmark calculation results belonged to the same group, one calculation result was found predictable from the other. An example was shown for each of the Benchmarks. While the evaluated nuclear data seemed the main factor for the classification, further investigations were required for finding other factors. (author)

  2. The Electric Car Challenge.

    Science.gov (United States)

    Diehl, Brian E.

    1997-01-01

    Describes the Electric Car Challenge during which students applied methods of construction to build lightweight, strong vehicles that were powered by electricity. The activity required problem solving, sheet metal work, electricity, design, and construction skills. (JOW)

  3. A New Energy-Based Method for 3-D Finite-Element Nonlinear Flux Linkage computation of Electrical Machines

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Ritchie, Ewen

    2011-01-01

    This paper presents a new method for computation of the nonlinear flux linkage in 3-D finite-element models (FEMs) of electrical machines. Accurate computation of the nonlinear flux linkage in 3-D FEM is not an easy task. Compared to the existing energy-perturbation method, the new technique......-perturbation method. The new method proposed is validated using experimental results on two different permanent magnet machines....

  4. Persistence of oxidation state III of gold in thione coordination

    Science.gov (United States)

    Jääskeläinen, Sirpa; Koskinen, Laura; Kultamaa, Matti; Haukka, Matti; Hirva, Pipsa

    2017-05-01

    Ligands N,N'-tetramethylthiourea and 2-mercapto-1-methyl-imidazole form stable Au(III) complexes [AuCl3(N,N'-tetramethylthiourea)] (1) and [AuCl3(2-mercapto-1-methyl-imidazole)] (2) instead of reducing the Au(III) metal center into Au(I), which would be typical for the attachment of sulfur donors. Compounds 1 and 2 were characterized by spectroscopic methods and by X-ray crystallography. The spectroscopic details were explained by simulation of the UV-Vis spectra via the TD-DFT method. Additionally, computational DFT studies were performed in order to find the reason for the unusual oxidation state in the crystalline materials. The preference for Au(III) can be explained via various weak intra- and intermolecular interactions present in the solid state structures. The nature of the interactions was further investigated by topological charge density analysis via the QTAIM method.

  5. System and method of modulating electrical signals using photoconductive wide bandgap semiconductors as variable resistors

    Science.gov (United States)

    Harris, John Richardson; Caporaso, George J; Sampayan, Stephen E

    2013-10-22

    A system and method for producing modulated electrical signals. The system uses a variable resistor having a photoconductive wide bandgap semiconductor material construction whose conduction response to changes in amplitude of incident radiation is substantially linear throughout a non-saturation region to enable operation in non-avalanche mode. The system also includes a modulated radiation source, such as a modulated laser, for producing amplitude-modulated radiation with which to direct upon the variable resistor and modulate its conduction response. A voltage source and an output port, are both operably connected to the variable resistor so that an electrical signal may be produced at the output port by way of the variable resistor, either generated by activation of the variable resistor or propagating through the variable resistor. In this manner, the electrical signal is modulated by the variable resistor so as to have a waveform substantially similar to the amplitude-modulated radiation.

  6. Electric power production contra electricity savings

    International Nuclear Information System (INIS)

    Schleisner, L.; Grohnheit, P.E.; Soerensen, H.

    1991-01-01

    The expansion of electricity-producing plants has, in Denmark until now, taken place in accordance with the demand for electricity. Recently, it has been suggested that the cost of the further development of such systems is greater than the cost of instigating and carrying out energy conservation efforts. The aim of the project was to evaluate the consequences for power producing plants of a reduction of the electricity consumption of end-users. A method for the analysis of the costs involved in the system and operation of power plants contra the costs that are involved in saving electricity is presented. In developing a model of this kind, consideration is given to the interplay of the individual saving project and the existing or future electricity supply. Thus it can be evaluated to what extent it would be advisable to substitute investments in the development of the capacity of the power plants with investments in the reduction of electricity consumption by the end users. This model is described in considerable detail. It will be tested in representative situations and locations throughout the Nordic countries. (AB) 17 refs

  7. A Simple and Rapid Complexometric Determination of Thallium(III ...

    African Journals Online (AJOL)

    A simple, rapid and selective complexometric method is proposed for the determination of thallium(III), using mercaptoethane(EtSH) as demasking agent. The sample solution containing Tl(III) is first complexed with excess EDTA and the surplus EDTA is removed by titration at pH 5–6 with zinc sulphate solution using ...

  8. [Determination of electric field distribution in dielectric barrier surface glow discharge by spectroscopic method].

    Science.gov (United States)

    Li, Xue-chen; Jia, Peng-ying; Liu, Zhi-hui; Li, Li-chun; Dong, Li-fang

    2008-12-01

    In the present paper, stable glow discharges were obtained in air at low pressure with a dielectric barrier surface discharge device. Light emission from the discharge was detected by photomultiplier tubes and the research results show that the light signal exhibited one discharge pulse per half cycle of the applied voltage. The light pulses were asymmetric between the positive half cycle and the negative one of the applied voltage. The images of the glow surface discharge were processed by Photoshop software and the results indicate that the emission intensity remained almost constant for different places with the same distance from the powered electrode, while the emission intensity decreased with the distance from the powered electrode increasing. In dielectric barrier discharge, net electric field is determined by the applied voltage and the wall charges accumulated on the dielectric layer during the discharge, and consequently, it is important to obtain information about the net electric field distribution. For this purpose, optical emission spectroscopy method was used. The distribution of the net electric field can be deduced from the intensity ratio of spectral line 391.4 nm emitted from the first negative system of N2+ (B 2sigma u+ -->X 2sigma g+) to 337.1 nm emitted from the second positive system of N2 (C 3IIu-B 3IIg). The research results show that the electric field near the powered electric field is higher than at the edge of the discharge. These experimental results are very important for numerical study and industrial application of the surface discharge.

  9. CALCULATION OF A MECHANICAL CHARACTERISTIC OF ELECTRIC TRACTION MOTOR OF ELECTRIC VEHICLE

    Directory of Open Access Journals (Sweden)

    Phuong Le Ngo

    2017-01-01

    Full Text Available The traction characteristic of an electric vehicle is the main characteristic of mechanical system that reflects its key performance indicators. Implementation of the traction characteristic is based on controlling angular speed and torque of electric traction motor in an automatic control system. The static mechanical characteristic of an electric traction motor in an automatic control system is the most important characteristic that determines weight, size and operating characteristics of an electric traction motor and serves as the basis for design. The most common variants of constructive implementation of a traction electric drive are analyzed, and a scheme is chosen for further design. Lagrange’s equation for electric mechanical system with one degree of freedom is written in generalized coordinates. In order to determine the generalized forces, elementary operation of all moments influencing on a moving car has been calculated. The resulting equation of motion of the electric vehicle corresponding to the design scheme, as well as the expressions for calculation of characteristic points of static mechanical characteristics of traction motor (i.e. the maximum and minimum time, minimum power are obtained. In order to determine the nominal values of the angular velocity and the power of electric traction motor, a method based on ensuring the movement of the vehicle in the standard cycle has been developed. The method makes it possible to calculate characteristic points of the mechanical characteristic with the lowest possible power rating. The algorithm for calculation of mechanical characteristics of the motor is presented. The method was applied to calculate static mechanical characteristic of an electric traction motor for a small urban electric truck.

  10. Synthesis of Ruthenium(III Phthalocyanine with Di-axial Bromo Ligands - A Promising Molecular Conductor with Giant Negative Magnetoresistance

    Directory of Open Access Journals (Sweden)

    Mario A.V. Gamboa

    2015-01-01

    Full Text Available The electron transport of Phthalocyanines (Pc with central metal and di-axial ligands (such as FeIII(PcL2; where L = CN, Cl, Br originates from its intermolecular Pc π-π orbital overlap while its giant negative magnetoresistance (GNMR arises from its intramolecular Pc-π(HOMO and Fe-d (s=1/2 interaction. However, the π-d interaction tends to localize itinerant electrons resulting in the decrease in the conductivity of the FeIII(PcL2 series compared to the non-magnetic CoIII(PcL2 where π-d interaction is absent. More so, the axial ligand field energy of the FeIII(PcL2 system is found to have the ability to proportionally modulate the π-d interaction. In reference thereof, theoretical calculations point that isostructural RuIII(PcBr2 would provide the best balance of π-d orbital energy interplay. That is, RuIII(PcBr2 is expected to be a molecule with high electrical conductivity and GNMR which would make it an ideal magnetic molecular conductor. This paper reports on the synthesis of RuIII(PcBr2.

  11. Complexation of biological ligands with lanthanides(III) for MRI: Structure, thermodynamic and methods; Complexation des cations lanthanides trivalents par des ligands d'origine biologique pour l'IRM: Structure, thermodynamique et methodes

    Energy Technology Data Exchange (ETDEWEB)

    Bonnet, C

    2006-07-15

    New cyclic ligands derived from sugars and amino-acids form a scaffold carrying a coordination sphere of oxygen atoms suitable to complex Ln(III) ions. In spite of their rather low molecular weights, the complexes display surprisingly high relaxivity values, especially at high field. The ACX and BCX ligands, which are acidic derivatives of modified and cyclo-dextrins, form mono and bimetallic complexes with Ln(III). The LnACX and LnBCX complexes show affinities towards Ln(III) similar to those of tri-acidic ligands. In the bimetallic Lu2ACX complex, the cations are deeply embedded in the cavity of the ligand, as shown by the X-ray structure. In aqueous solution, the number of water molecules coordinated to the cation in the LnACX complex depends on the nature and concentration of the alkali ions of the supporting electrolyte, as shown by luminescence and relaxometric measurements. There is only one water molecule coordinated in the LnBCX complex, which enables us to highlight an important second sphere contribution to relaxivity. The NMR study of the RAFT peptidic ligand shows the complexation of Ln(III), with an affinity similar to those of natural ligands derived from calmodulin. The relaxometric study also shows an important second sphere contribution to relaxivity. To better understand the intricate molecular factors affecting relaxivity, we developed new relaxometric methods based on probe solutes. These methods allow us to determine the charge of the complex, weak affinity constants, trans-metallation constants, and the electronic relaxation rate. (author)

  12. Thermodynamic data for predicting concentrations of Pu(III), Am(III), and Cm(III) in geologic environments

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Dhanpat; Rao, Linfeng; Weger, H.T.; Felmy, A.R. [Pacific Northwest National Laboratory, WA (United States); Choppin, G.R. [Florida State University, Florida (United States); Yui, Mikazu [Japan Nuclear Cycle Development Inst., Tokai Works, Tokai, Ibaraki (Japan)

    1999-01-01

    This report provides thermodynamic data for predicting concentrations of Pu(III), Am(III), and Cm(III) in geologic environments, and contributes to an integration of the JNC chemical thermodynamic database, JNC-TDB (previously PNC-TDB), for the performance analysis of geological isolation system for high-level radioactive wastes. Thermodynamic data for the formation of complexes or compounds with hydroxide, chloride, fluoride, carbonate, nitrate, sulfate and phosphate are discussed in this report. Where data for specific actinide(III) species are lacking, the data were selected based on chemical analogy to other trivalent actinides. In this study, the Pitzer ion-interaction model is mainly used to extrapolate thermodynamic constants to zero ionic strength at 25degC. (author)

  13. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  14. Luminescence study on solvation of americium(III), curium(III) and several lanthanide(III) ions in nonaqueous and binary mixed solvents

    International Nuclear Information System (INIS)

    Kimura, T.; Nagaishi, R.; Kato, Y.; Yoshida, Z.

    2001-01-01

    The luminescence lifetimes of An(III) and Ln(III) ions [An=Am and Cm; Ln=Nd, Sm, Eu, Tb and Dy] were measured in dimethyl sulfoxide(DMSO), N,N-dimethylformamide(DMF), methanol(MeOH), water and their perdeuterated solvents. Nonradiative decay rates of the ions were in the order of H 2 O > MeOH > DMF > DMSO, indicating that O-H vibration is more effective quencher than C-H, C=O, and S=O vibrations in the solvent molecules. Maximal lifetime ratios τ D /τ H were observed for Eu(III) in H 2 O, for Sm(III) in MeOH and DMF, and for Sm(III) and Dy(III) in DMSO. The solvent composition in the first coordination sphere of Cm(III) and Ln(III) in binary mixed solvents was also studied by measuring the luminescence lifetime. Cm(III) and Ln(III) were preferentially solvated by DMSO in DMSO-H 2 O, by DMF in DMF-H 2 O, and by H 2 O in MeOH-H 2 O over the whole range of the solvent composition. The order of the preferential solvation, i.e., DMSO > DMF > H 2 O > MeOH, correlates with the relative basicity of these solvents. The Gibbs free energy of transfer of ions from water to nonaqueous solvents was further estimated from the degree of the preferential solvation. (orig.)

  15. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  16. Luminescence studies of Sm(III) and Cm(III) complexes in NaSCN/DHDECMP extraction systems

    CERN Document Server

    Chung, D Y; Kimura, T

    1999-01-01

    Laser-induced fluorescence (LIF) studies of Sm(III) and Cm(III) complexes in the NaSCN/DHDECMP solvent extraction system were carried out. Luminescence lifetimes were measured to determine the number of water molecules coordinated to Sm(III), Tb(III), Dy(III), and Cm(III) in the sodium thiocyanate solution and in the DHDECMP phase. The hydration number of Sm(III), Tb(III), Dy(III), and Cm(III) in the sodium thiocyanate solution decreased linearly with increasing sodium thiocyanate concentration. The hydration numbers of Sm(III), Dy(III), and Cm(III) in the DHDECMP phase decreased with increasing sodium thiocyanate concentration. The water molecules in the inner coordination sphere of Sm(III) and Dy(III) extracted into the DHDECMP were not completely removed at low sodium thiocyanate concentration but decreased with increasing sodium thiocyanate concentration. However, in the case of Cm(III) extracted into the DHDECMP phase from the sodium thiocyanate solution, there was no water in the inner coordination sphe...

  17. The use of electrical devices for the treatment of bladder dysfunction: a review of methods.

    NARCIS (Netherlands)

    Balken, M.R. van; Vergunst, H.; Bemelmans, B.L.H.

    2004-01-01

    PURPOSE: We reviewed the literature on the application of various devices and techniques for the electrical stimulation treatment of lower urinary tract dysfunction with respect to mechanism of action and clinical outcome. MATERIALS AND METHODS: A systematic review was done in PubMed of publications

  18. Reactivity of tris(acetylacetonato) iron(III) with tridentate [ONO] donor Schiff base as an access to newer mixed-ligand iron(III) complexes

    Science.gov (United States)

    Bhattacharjee, Chira R.; Goswami, Pankaj; Pramanik, Harun A. R.; Paul, Pradip C.; Mondal, Paritosh

    2011-05-01

    Two new mixed-ligand iron(III) complexes, [Fe(L n)(acac)(C 2H 5OH)] incorporating coordinated ethanol from the reaction solvent were accessed from the reaction of [Fe(acac) 3] with [ONO] donor dibasic tridentate unsymmetrical Schiff base ligands derived from condensation of 2-hydroxy-1-napthaldehyde with 2-aminophenol (H 2L 1) or 2-aminobenzoic acid (H 2L 2). The thermal study (TGA-DTA) provided evidence for weakly bound ethanol which is readily substituted by neutral N-donor molecule imidazole, benzimidazole or pyridine to produce an array of newer complexes, [Fe(L n)(acac)X] ( n = 1, 2; X = Im, Bim, Py). The compounds were characterized by elemental analyses, FT-IR, UV-vis, solution electrical conductivity, FAB mass, 1H and 13C NMR spectroscopy. Room temperature magnetic susceptibility measurements ( μeff ˜ 5.8 B.M.) are consistent with spin-free octahedral iron(III) complexes. Cyclic voltammetry of ethanol complexes revealed a quasi-reversible one electron redox response (Δ Ep > 100 mV) for the Fe(III)/Fe(II) couple. Low half wave redox potential ( E1/2) values suggested easy redox susceptibility. The ground state geometries of the ethanol and imidazole complexes have been ascertained to be distorted octahedral by density functional theory using DMol3 program at BLYP/DNP level.

  19. A method to improve tree water use estimates by distinguishing sapwood from heartwood using Electrical Resistivity Tomography

    Science.gov (United States)

    Guyot, A.; Ostergaard, K.; Lenkopane, M.; Fan, J.; Lockington, D. A.

    2011-12-01

    Estimating whole-plant water use in trees requires reliable and accurate methods. Measuring sap velocity and extrapolating to tree water use is seen as the most commonly used. However, deducing the tree water use from sap velocity requires an estimate of the sapwood area. This estimate is the highest cause of uncertainty, and can reach more than 50 % of the uncertainty in the estimate of water use per day. Here, we investigate the possibility of using Electrical Resistivity Tomography to evaluate the sapwood area distribution in a plantation of Pinus elliottii. Electric resistivity tomographs of Pinus elliottii show a very typical pattern of electrical resistivity, which is highly correlated to sapwood and heartwood distribution. To identify the key factors controlling the variation of electrical resistivity, cross sections at breast height for ten trees have been monitored with electrical resistivity tomography. Trees have been cut down after the experiment to identify the heartwood/sapwood boundaries and to extract wood and sap samples. pH, electrolyte concentration and wood moisture content have then been analysed for these samples. Results show that the heartwood/sapwood patterns are highly correlated with electrical resistivity, and that the wood moisture content is the most influencing factor controlling the variability of the patterns. These results show that electric resistivity tomography could be used as a powerful tool to identify the sapwood area, and thus be used in combination with sapflow sensors to map tree water use at stand scale. However, if Pinus elliottii shows typical patterns, further work is needed to identify to see if there are species - specific characterictics as shown in previous works (, electrolyte gradients from the bark to the heartwood). Also, patterns of high resistivity in between needles positions, which are not correlated with either wood moisture content or sapwood, appear to be artifacts. Thus, inversion methods have also to

  20. Modeling of Electric Field Around 100 MVA 150/20 kV Power Transformator using Charge Simulation Method

    Directory of Open Access Journals (Sweden)

    Noviadi Arief Rachman

    2013-07-01

    Full Text Available Charge Simulation Method is one of the field theory that can be used as an approach to calculate the electromagnetic distribution on the electrical conductor. This paper discussed electric field modeling around power transformator by using Matlab to find the safety distance. The safe distance threshold of the electric field to human health refers to WHO and SNI was 5 kV/m. The specification of the power transformator was three phases, 150/20 kV, and 100 MVA. The basic concept is to change the distribution charge on the conductor or dielectric polarization charge with a set of discrete fictitious charge. The value of discrete fictitious charge was equivalent to the potential value of the conductor, and became a reference to calculate the electric field around the surface contour of the selected power transformator. The measurement distance was 5 meter on each side of the transformator surface. The results showed that the magnitude of the electric field at the front side was 5541 V/m, exceeding the safety limits.