WorldWideScience

Sample records for elbow suction pipes

  1. Flexibility of trunnion piping elbows

    International Nuclear Information System (INIS)

    Lewis, G.D.; Chao, Y.J.

    1987-01-01

    Flexibility factors and stress indices for piping component such as straight pipe, elbows, butt-welding tees, branch connections, and butt-welding reducers are contained in the code, but many of the less common piping components, like the trunnion elbow, do not have flexibility factors or stress indices defined. The purpose of this paper is to identify the in-plane and out-of-plane flexibility factors in accordance with code procedures for welded trunnions attached to the tangent centerlines of long radius elbows. This work utilized the finite element method as applicable to plates and shells for calculating the relative rotations of the trunnion elbow-ends for in-plane and out-of-plane elbow moment loadings. These rotations are used to derive the corresponding in-plane and out-of-plane flexibility factors. (orig./GL)

  2. Static analysis of a piping system with elbows

    International Nuclear Information System (INIS)

    Bryan, B.J.

    1994-01-01

    Vibration tests of elbows to failure were performed in Japan in the early 1970s. The piping system included two elbows and an eccentric mass. Tests were run both pressurized and unpressurized. This report documents a static analysis of the piping system in which the elbows are subjected to out of plane bending. The effects of internal pressure and material plasticity are investigated

  3. MAXIMUM AIR SUCTION INTO HORIZONTAL OPEN ENDED CYLINDRICAL LOUVERED PIPE

    Directory of Open Access Journals (Sweden)

    SAMEER RANJAN SAHU

    2017-02-01

    Full Text Available The main approach behind the present numerical investigation is to estimate the mass flow rate of air sucked into a horizontal open-ended louvered pipe from the surrounding atmosphere. The present numerical investigation has been performed by solving the conservation equations for mass, momentum and energy along with two equation based k-ɛ model for a louvered horizontal cylindrical pipe by finite volume method. It has been found from the numerical investigation that mass suction rate of air into the pipe increases with increase in louvered opening area and the number of nozzles used. Keeping other parameters fixed, for a given mass flow rate there exists an optimum protrusion of nozzle for highest mass suction into the pipe. It was also found from the numerical investigation that increasing the pipe diameter the suction mass flow rate of air was increased.

  4. Turbulent flow with suction in smooth and rough pipes

    International Nuclear Information System (INIS)

    Verdier, Andre.

    1977-11-01

    It concerns an experimental study of turbulent flow inside a pipe with rough and porous wall and suction applied through it. The first part recall the basic knowledge concerning the turbulent flow with roughness. In second part statistical equations of fluid wall stress are written in the case of a permeable rough wall, in order to underline the respective role played by viscosity and pressure terms. In the third part the dynamic equilibrium of the flow is experimentally undertaken in the smooth and rough range with and without wall suction. Some empirical formulae are proposed for the mean velocity profiles in the inertial range and for friction velocity with suction. In the case of the sand roughness used, it does not seem that critical Reynolds number of transition from smooth to rough range is varied [fr

  5. Tissue holding device for use during surgical procedure, has contact body with suction foot and suction mouth that is surrounded by rim, and suction pipe connected to suction chamber

    OpenAIRE

    Vonck, D.; Goossens, R.H.M.; Flipsen, S.F.J.; Jakimowicz, J.J.; Van der Putten, E.P.W.

    2009-01-01

    The device has a locking ring (5), a connector (6), and a contact body (1) with a suction foot and a suction mouth (8), where the mouth is surrounded by a rim (10), which is substantially located in a plane of the suction foot. A suction chamber (9) has a sieve-shaped inner wall (2) and a transparent side wall, and a suction pipe (11) is connected to the chamber.

  6. Inelastic analysis of Battelle-Columbus piping elbow creep test

    International Nuclear Information System (INIS)

    Dhalla, A.K.; Newman, S.Z.

    1979-01-01

    Analytical results are presented for room temperature and 593 deg. C creep bending deformation of a piping elbow structure tested at the Battelle-Columbus Laboratory. This analysis was performed in support of the International Piping Benchmark Problem Program being coordinated by ORNL. Results are presented for both simplified and refined structural models, and compared with test measurements reported by the Battelle-Columbus Laboratory. (author)

  7. Investigation on ultrasonic guided waves propagation in elbow pipe

    International Nuclear Information System (INIS)

    Qi, Minxin; Zhou, Shaoping; Ni, Jing; Li, Yong

    2016-01-01

    Pipeline plays an indispensable role in process industries, whose structural integrity is of great significance for the safe production. In this paper, the axial crack-like defects in 90° elbows are inspected by using the T (0, 1) mode guided waves. The detection sensitivity for different defect locations is firstly investigated by guided waves experimentally. The propagation of guided waves in the bent pipe is then simulated by using finite element method. The results show that the rates of T (0, 1) mode passing through elbow correlate strongly with the excitation frequency. Less mode conversion is generated at the frequency of 38 kHz when passing through the elbow, while most of energy converted into F (1, 2) mode at the frequency of 75 kHz. The crack in different locations of the elbow can affect the rates of mode conversion. It can be found that the crack in the middle of the elbow inhibits mode conversion and shares the highest detection sensitivity, while the crack in the extrados of elbow causes more mode conversion.

  8. Experimental study of plastic responses of pipe elbows

    International Nuclear Information System (INIS)

    Greenstreet, W.L.

    1978-01-01

    Load-deflection responses were determined experimentally for sixteen 152.4-mm (6-in.) (nominal) commercial carbon steel pipe elbows and four 152.4-mm (6-in.) stainless steel elbows. Each specimen was loaded with an external force of sufficient magnitude to produce predominantly plastic response. The influences of bend radius and wall thickness were studied, as well as the effect of internal prssure on load-deflection behavior. Comparisons of results from stainless steel and from carbon steel elbows indicate differences in responses attributable to material differences. The results were interpreted in terms of limit analysis concepts, and collapse loads were determined. Trends given by the collapse loads are identified and discussed

  9. Probabilistic assessment of critically flawed LMFBR PHTS piping elbows

    International Nuclear Information System (INIS)

    Balkey, K.R.; Wallace, I.T.; Vaurio, J.K.

    1982-01-01

    One of the important functions of the Primary Heat Transport System (PHTS) of a large Liquid Metal Fast Breeder Reactor (LMFBR) plant is to contain the circulating radioactive sodium in components and piping routed through inerted areas within the containment building. A significant possible failure mode of this vital system is the development of cracks in the piping components. This paper presents results from the probabilistic assessment of postulated flaws in the most-critical piping elbow of each piping leg. The criticality of calculated maximum sized flaws is assessed against an estimated material fracture toughness to determine safety factors and failure probability estimates using stress-strength interference theory. Subsequently, a different approach is also employed in which the randomness of the initial flaw size and loading are more-rigorously taken into account. This latter approach yields much smaller probability of failure values when compared to the stress-strength interference analysis results

  10. Resolution of thermal striping issue downstream of a horizontal pipe elbow in stratified pipe flow

    International Nuclear Information System (INIS)

    Kuzay, T.M.; Kasza, K.E.

    1985-01-01

    A thermally stratified pipe flow produced by a thermal transient when passing through a horizontal elbow as a result of secondary flow gives rise to large thermal fluctuations on the inner curvature wall of the downstream piping. These fluctuations were measured in a specially instrumented horizontal pipe and elbow system on a test set-up using water in the Mixing Components Technology Facility (MCTF) at Argonne National Laboratory (ANL). This study is part of a larger program which is studying the influence of thermal buoyancy on general reactor component performance. This paper discusses the influence of pipe flow generated thermal oscillations on the thermal stresses induced in the pipe walls. The instrumentation was concentrated around the exit plane of the 90 0 sweep elbow, since prior tests had indicated that the largest thermal fluctuations would occur within about one hydraulic diameter downstream of the elbow exit. The thermocouples were located along the inner curvature of the piping and measured the near surface fluid temperature. The test matrix involved thermal downramps under turbulent flow conditions

  11. Resolution of thermal striping issue downstream of a horizontal pipe elbow in stratified pipe flow. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kuzay, T.M.; Kasza, K.E.

    1985-01-01

    A thermally stratified pipe flow produced by a thermal transient when passing through a horizontal elbow as a result of secondary flow gives rise to large thermal fluctuations on the inner curvature wall of the downstream piping. These fluctuations were measured in a specially instrumented horizontal pipe and elbow system on a test set-up using water in the Mixing Components Technology Facility (MCTF) at Argonne National Laboratory (ANL). This study is part of a larger program which is studying the influence of thermal buoyancy on general reactor component performance. This paper discusses the influence of pipe flow generated thermal oscillations on the thermal stresses induced in the pipe walls. The instrumentation was concentrated around the exit plane of the 90/sup 0/ sweep elbow, since prior tests had indicated that the largest thermal fluctuations would occur within about one hydraulic diameter downstream of the elbow exit. The thermocouples were located along the inner curvature of the piping and measured the near surface fluid temperature. The test matrix involved thermal downramps under turbulent flow conditions.

  12. Propagation of ovalization along straight pipes and elbows

    International Nuclear Information System (INIS)

    Millard, A.; Roche, R.L.

    1981-01-01

    The aim of this paper is to present analytical solutions for the propagation of evalization and the variation of the flexibility factor along pipe bends terminated by straight pipes or flanges, under in-plane bending, assuming an elastic material behaviour. The influence of the various strains in analysed in the simple case of a straight pipe, subjected to an elliptical cross-section shape deformation at one end. The results enlighten the very important part played by the distorsion in the propagation. They have been compared with finite elements solutions and with simple experiments. The solution is developed for an elbow terminated by a straight pipe or a flange, following the Von Karman's approach: local displacements are expanded in Fourier series, the coefficients of which vary along the curvilinear abscissa, like the rotation of the cross-section as a whole; the differential equations as well as the boundary conditions are found by minimization of the total potential energy of the assembly. The solutions are compared to existing and experimental results. (orig./HP)

  13. Unsteady hydraulic characteristics in pipe with elbow under high Reynolds condition

    Energy Technology Data Exchange (ETDEWEB)

    Ono, A.; Kimura, N.; Kamide, H.; Tobita, A. [Japan Atomic Energy Agency, O-arai, Ibaraki (Japan)

    2011-07-01

    In the design of Japan Sodium-cooled Fast Reactor (JSFR), coolant velocity is beyond 9 m/s in the primary hot leg pipe of 1.27 m diameter. The Reynolds number in the piping reaches 4.2x10{sup 7}. Moreover, a short-elbow (r/D=1.0, r: curvature radius, D: pipe diameter) is adopted in the hot leg pipe in order to achieve compact plant layout and reduce plant construction cost. Therefore, the flow-induced vibration (FIV) arising from the piping geometry may occur in the short-elbow pipe. The FIV is due to the excitation force which is caused by the pressure fluctuation on the wall. The pressure fluctuation on the pipe wall is closely related with the flow fluctuation. In this study, water experiments using two types of 1/8 scaled elbows with different curvature ratio, r/D=1.0 and 1.5 (short-elbow and long-elbow), were conducted in order to investigate the mechanism of velocity and pressure fluctuation in the elbow and its downstream. The experiments were carried out at Re=5.4x10{sup 5} conditions. Measurement of velocity fluctuation and pressure fluctuation in two types of elbows with different curvature revealed that behavior of separation region and the circumferential secondary flow affected the pressure fluctuation on the wall of the elbow greatly. (author)

  14. Ratcheting failure of pressurised straight pipes and elbows under reversed bending

    International Nuclear Information System (INIS)

    Vishnuvardhan, S.; Raghava, G.; Gandhi, P.; Saravanan, M.; Goyal, Sumit; Arora, Punit; Gupta, Suneel K.; Bhasin, Vivek

    2013-01-01

    Ratcheting studies were carried out on Type 304LN stainless steel straight pipes and elbows subjected to steady internal pressure and cyclic bending load. The internal pressure for all the straight pipes was 35 MPa and in the case of elbows the internal pressure was varied for different elbows, ranging from 27.6 MPa to 39.2 MPa. Cyclic bending load was applied on the specimens by subjecting them to different levels of load-line displacement. The specimens have undergone significant ratchet swelling (ballooning), ovalization and consequent thinning of the cross-section during ratcheting. The straight pipes failed either by occurrence of through-wall crack accompanied by simultaneous ballooning, or bursting with simultaneous ballooning. All the elbows failed by occurrence of through-wall crack accompanied by simultaneous ballooning. Ratcheting behaviour of straight pipes and elbows were compared and it was generally inferred that ratcheting was more pronounced in straight pipes than in elbows. -- Graphical abstract: Strain history for the specimen QCE-RAT-6-L1. Highlights: • Studies were carried out under combined internal pressure and cyclic bending. • Ratcheting strains were measured at critical locations of the specimens. • Quantified the percentage of ballooning, ovalization and reduction in thickness. • Modes of ratcheting failure of straight pipes and elbows are studied. • Inferred that ratcheting is more pronounced in straight pipes than in elbows

  15. Work Turbochargers under Reduced Pressure in the Suction Pipe

    Directory of Open Access Journals (Sweden)

    I. V. Filippov

    2014-01-01

    Full Text Available In case consumers have a significant need in the compressed air, the use of turbochargers is a promising direction. The turbocharger operation is largely defined by its running conditions, namely parameters of the intake air and cooling conditions.The paper presents the results of experimental studies of turbochargers type 4CI 425MX4 of series "CENTAC" manufactured by INGERSOL-RAND, which were performed under industrial conditions in a mountainous area with difficult climatic conditions. There were, essentially, no researches of running turbochargers in mountainous areas. The combination of low atmospheric pressure, high temperature of intake air, and specific cooling conditions causes abnormal mode of turbocharger operation. The results of theoretical studies of such modes are found only in N.M. Barannikov’s work while there is no mentioned empirical research at all.Experimental studies were conducted under industrial conditions in the form of passive experiment. All measurements were carried out using a standard measuring system included in the system of compressor monitor and control. During the experimental studies temperature regimes at the turbocharger stage were controlled, and turbocharger pressure ratio and weight output were determined.The results of the research can be formulated as follows:- highland conditions and seasonal variations of atmospheric air have a negative impact on the operation of the turbochargers;- specific work value as an indicator of the economical efficiency exceeds that of the nameplate by 12...21 % depending on the climatic conditions.The problem of functioning normalization of the turbochargers seems to be relevant not only for the considered type of compressor, but also for that of the less power. It is proposed to consider two ways:- installation of the fifth additional stage;- mechanical pressurization in the suction pipe by means of blowers of high power.To make final decision it is necessary to conduct

  16. Influences of overload on low cycle fatigue behaviors of elbow pipe with local wall thinning

    International Nuclear Information System (INIS)

    Sato, Kyohei; Ogino, Kanako; Takahashi, Koji; Ando, Kotoji; Urabe, Yoshio

    2011-01-01

    Low cycle fatigue tests were conducted using 100A elbow pipe specimens with or without local wall thinning. Local wall thinning was machined on the inside of the extrados of test elbows to simulate metal loss due to flow-accelerated corrosion or liquid droplet impingement erosion. Low cycle fatigue tests were carried out under displacement control with an inner pressure of 9 MPa. To simulate seismic events, low cycle fatigue tests were carried out on elbow pipe subjected to cyclic overloads. Regardless of local wall thinning, fatigue life of overload pipe was not so different from that of the non-overload pipe in appearance. Miner's rule can be applied to evaluate fatigue life of the elbow pipes with and without wall thinning, even if overload is applied. (author)

  17. Seismic Capacity Estimation of Steel Piping Elbow under Low-cycle Fatigue Loading

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Bub Gyu; Kim, Sung Wan; Choi, Hyoung Suk; Kim, Nam Sik [Pusan National University, Busan (Korea, Republic of); Hahm, Dae Gi [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In some cases, this large relative displacement can increase seismic risk of the isolated facility. Especially, a inelastic behavior of crossover piping system to connect base isolated building and fixed base building can caused by a large relative displacement. Therefore, seismic capacity estimation for isolated piping system is needed to increase safety of nuclear power plant under seismic condition. Dynamic behavior analysis of piping system under seismic condition using shake table tests was performed by Touboul et al in 1995. In accordance with their study, plastic behavior could be occurred at pipe elbow under seismic condition. Experimental researches for dynamic behavior of typical piping system in nuclear power plant have been performed for several years by JNES(Japan Nuclear Energy Safety Organization) and NUPEC(Nuclear Power Engineering Corporation). A low cycle ratcheting fatigue test was performed with scaled model of elbow which is a weakest component in piping system by Mizuno et al. In-plane cyclic loading tests under internal pressure condition were performed to evaluate the seismic capacity of the steel piping elbow. Leakage phenomenon occurred on and near the crown in piping elbow. Those cracks grew up in axial direction. The fatigue curve was estimated from test results. In the fatigue curve, loading amplitude exponentially decreased as the number of cycles increased. A FEM model of piping elbow was modified with test results. The relationships between displacement and force from tests and numerical analysis was well matched.

  18. Experimental study on fluid mixing phenomena in T-pipe junction with upstream elbow

    International Nuclear Information System (INIS)

    Hiroshi Ogawa; Minoru Igarashi; Nobuyuki Kimura; Hideki Kamide

    2005-01-01

    Full text of publication follows: Temperature fluctuation in fluid causes high cycle thermal fatigue in shroud structure according to its amplitude and frequency. There are still some incidents of thermal fatigue and leakage in light water reactors (Japanese PWR Tomari-2 in 2003, French PWR CIVAUX in 1998), and also in sodium cooled reactors (French FBR Phenix in 1992). Mixing tee is a typical component where temperature fluctuation occurs. Water experiment has been carried out to investigate temperature fluctuation characteristics and flow velocity field in a simple T-pipe junction with straight inlet pipings for main and branch lines; test facility is named as WATLON (Water Experiment on Fluid Mixing in T-pipe with Long Cycle Fluctuation). Here, influence of upstream elbow in the main pipe was studied in the WATLON facility. Elbow can be set near the mixing tee in a real plant. Outlet of the elbow has biased velocity distribution and also the secondary flow, which decays unsteadily. Temperature distribution in the mixing tee was measured by a movable tree with 17 thermocouples and velocity field was measured by Dynamic PIV (high speed particle image velocimetry) with sampling frequency of 200 Hz. Measured temperature showed that fluctuation intensity near the wall was larger in the elbow geometry than in the straight inlet pipes in a case of wall jet (branch flow velocity is smaller than main pipe flow velocity); high intensity region in the elbow case was enlarged around the jet exiting from the branch pipe. The result of flow velocity measurement showed that secondary flow and biased flow velocity distributions due to the elbow influenced bending of the jet exiting from the branch pipe and the temperature fluctuation intensity around the jet. The detailed flow velocity distributions and the secondary flow of upstream elbow can be measured by Dynamic PIV. Influence of such elbow was discussed based on detailed temperature data together with fluctuated velocity

  19. Comparison of ICEPEL predictions with single elbow flexible piping system experiment

    International Nuclear Information System (INIS)

    A-Moneim, M.T.; Chang, Y.W.

    1978-01-01

    The ICEPEL Code for coupled hydrodynamic-structural response analysis of piping systems is used to analyze an experiment on the response of flexible piping systems to internal pressure pulses. The piping system consisted of two flexible Nickel-200 pipes connected in series through a 90 0 thick-walled stainless steel elbow. A tailored pressure pulse generated by a calibrated pulse gun is stabilized in a long thick-walled stainless steel pipe leading to the flexible piping system which ended with a heavy blind flange. The analytical results of pressure and circumferential strain histories are discussed and compared against the experimental data obtained by Stanford Research Institute

  20. Irrecoverable pressure loss coefficients for two out-of-plane piping elbows at high Reynolds number

    Energy Technology Data Exchange (ETDEWEB)

    Coffield, R.D.; Hammond, R.B.; McKeown, P.T.

    1999-02-08

    Pressure drops of multiple piping elbows were experimentally determined for high Reynolds number flows. The testing described has been performed in order to reduce uncertainties in the currently used methods for predicting irrecoverable pressure losses and also to provide a qualification database for computational fluid dynamics (CFD) computer codes. The earlier high Reynolds number correlations had been based on extrapolations over several orders of magnitude in Reynolds number from where the original database existed. Recent single elbow test data shows about a factor of two lower elbow pressure loss coefficient (at 40x 106 Reynolds number) than those from current correlations. This single piping elbow data has been extended in this study to a multiple elbow configuration of two elbows that are 90o out-of-plane relative to each other. The effects of separation distance and Reynolds number have been correlated and presented in a form that can be used for design application. Contrary to earlier extrapolations from low Reynolds numbers (Re c 1.0x 106), a strong Reynolds number dependence was found to exist. The combination of the high Reynolds number single elbow data with the multiple elbow interaction effects measured in this study shows that earlier design correlations are conservative by significant margins at high Reynolds numbers. Qualification of CFD predictions with this new high Reynolds number database will help guide the need for additional high Reynolds number testing of other piping configurations. The study also included velocity measurements at several positions downstream of the first and second test elbows using an ultrasonic flowmeter. Reasonable agreement after the first test elbow was found relative to flow fields that are known to exist from low Reynolds number visual tests and also from CFD predictions. This data should help to qualify CFD predictions of the three-dimensional flow stream downstream of the second test elbow.

  1. Determination of optimal tool parameters for hot mandrel bending of pipe elbows

    Science.gov (United States)

    Tabakajew, Dmitri; Homberg, Werner

    2018-05-01

    Seamless pipe elbows are important components in mechanical, plant and apparatus engineering. Typically, they are produced by the so-called `Hamburg process'. In this hot forming process, the initial pipes are subsequently pushed over an ox-horn-shaped bending mandrel. The geometric shape of the mandrel influences the diameter, bending radius and wall thickness distribution of the pipe elbow. This paper presents the numerical simulation model of the hot mandrel bending process created to ensure that the optimum mandrel geometry can be determined at an early stage. A fundamental analysis was conducted to determine the influence of significant parameters on the pipe elbow quality. The chosen methods and approach as well as the corresponding results are described in this paper.

  2. Parametric Study on Ultimate Failure Criteria of Elbow Piping Components in Seismically Isolated NPP

    Energy Technology Data Exchange (ETDEWEB)

    Hahm, Dae Gi; Ki, Min Kyu [KAERI, Daejeon (Korea, Republic of); Jeon, Bub Gyu; Kim, Nam Sik [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    It is well known that the interface pipes between isolated and non-isolated structures will become the most critical in the seismically isolated NPPs. Therefore, seismic performance of such interface pipes should be evaluated comprehensively especially in terms of the seismic fragility capacity. To evaluate the seismic capacity of interface pipes in the isolated NPP, firstly, we should define the failure mode and failure criteria of critical pipe components. Hence, in this study, we performed the dynamic tests of elbow components which were installed in a seismically isolated NPP, and evaluated the ultimate failure mode and failure criteria by using the test results. To do this, we manufactured 25 critical elbow component specimens and performed cyclic loading tests under the internal pressure condition. The failure mode and failure criteria of a pipe component will be varied by the design parameters such as the internal pressure, pipe diameter, loading type, and loading amplitude. From the tests, we assessed the effects of the variation parameters onto the failure criteria. For the tests, we generated the seismic input protocol of relative displacement between the ends of elbow component. In this paper, elbow in piping system was defined as a fragile element and numerical model was updated by component test. Failure mode of piping component under seismic load was defined by the dynamic tests of ultimate pipe capacity. For the interface piping system, the seismic capacity should be carefully estimated since that the required displacement absorption capacity will be increased significantly by the adoption of the seismic isolation system. In this study, the dynamic tests were performed for the elbow components which were installed in an actual NPPs, and the ultimate failure mode and failure criteria were also evaluated by using the test results.

  3. A Failure Estimation Method of Steel Pipe Elbows under In-plane Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Bub-Gyu Jeon

    2017-02-01

    Full Text Available The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.

  4. A failure estimation method of steel pipe elbows under in-plane cyclic loading

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Bub Gyu; Kim, Sung Wan; Choi, Hyoung Suk; Park, Dong Uk [Seismic Simulation Tester Center, Pusan National University, Yangsan (Korea, Republic of); Kim, Nam Sik [Dept. of Civil and Environmental Engineering, Pusan National University, Busan (Korea, Republic of)

    2017-02-15

    The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.

  5. A failure estimation method of steel pipe elbows under in-plane cyclic loading

    International Nuclear Information System (INIS)

    Jeon, Bub Gyu; Kim, Sung Wan; Choi, Hyoung Suk; Park, Dong Uk; Kim, Nam Sik

    2017-01-01

    The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation

  6. Sensitivity Analysis on Elbow Piping Components in Seismically Isolated NPP under Seismic Loading

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Hee Kun; Hahm, Dae Gi; Kim, Min Kyu [KAERI, Daejeon (Korea, Republic of); Jeon, Bub Gyu; Kim, Nam Sik [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    In this study, the FE model is verified using specimen test results and simulation with parameter variations are conducted. Effective parameters will randomly sampled and used as input values for simulations to be applied to the fragility analysis. pipelines are representative of them because they could undergo larger displacements when they are supported on both isolated and non-isolated structures simultaneously. Especially elbows are critical components of pipes under severed loading conditions such as earthquake action because strain is accumulated on them during the repeated bending of the pipe. Therefore, seismic performance of pipe elbow components should be examined thoroughly based on the fragility analysis. Fragility assessment of interface pipe should take different sources of uncertainty into account. However, selection of important sources and repeated tests with many random input values are very time consuming and expensive, so numerical analysis is commonly used. In the present study, finite element (FE) model of elbow component will be validated using the dynamic test results of elbow components. Using the verified model, sensitivity analysis will be implemented as a preliminary process of seismic fragility of piping system. Several important input parameters are selected and how the uncertainty of them are apportioned to the uncertainty of the elbow response is to be studied. Piping elbows are critical components under cyclic loading conditions as they are subjected large displacement. In a seismically isolated NPP, seismic capacity of piping system should be evaluated with caution. Seismic fragility assessment preliminarily needs parameter sensitivity analysis about the output of interest with different input parameter values.

  7. Design rules for piping: experimental validation of flexibility and elastic stress indices for elbows under bending

    International Nuclear Information System (INIS)

    Touboul, F.; Ben Jdidia, M.; Acker, D.

    1989-01-01

    Design rules for class 1 piping components are based on stress indices (B, C, K) and flexibility factors (k). For elbows, adjacent straight parts and internal pressure inhibit ovalization of the cross-section, so reducing the sub-mentioned indices. Published theoretical works and experimental results allow for improvement of coded values. End effect may be represented by a suitable function of the elbow angle. The favourable effect of pressure on C 2 , for fatigue damage evaluation, can be taken into account

  8. Evaluation of hyper-tempering and machining residual stresses in a pipe and a cast elbow

    International Nuclear Information System (INIS)

    Dupas, P.; Le Delliou, P.; Sussen, L.

    1995-01-01

    Cast elbows in austeno-ferritic stainless steel from the primary circuit of nuclear power plants suffer from important residual stresses initiated during their manufacturing (hyper-tempering followed by machining). Measurements and calculations were performed to determine these stresses. Measurements show a difference between circumferential stresses in the depth of a pipe and of an elbow. On the contrary, calculations indicate similar profiles. Thus, the experimental differences cannot be explained by a geometrical effect of the elbow. (J.S.). 4 refs., 5 figs

  9. Thermalhydraulic study of a stratified flow in a piping elbow (Application to the model Coufast)

    International Nuclear Information System (INIS)

    Peniguel, C.; Stephan, J.M.

    1992-11-01

    In PWR's, mechanical damages (cracks) have been detected at the internal faces of steam generator feedwater piping and also in dead legs, when thermal stratification occurs. To gain some understanding on these issues, experimental and numerical programs have been set up at EDF. This paper reports a thermalhydraulic study of an elbow geometry under operating conditions leading to the establishment of a stable stratified flow. Results obtained with ESTET (a three dimensional finite differences-finite volume code solving the averaged Navier-Stokes equations) and comparisons with experimental data obtained on COUFAST (an analytical mock up, scale 1 of a French 900-MW PWR steam generator pipe elbow) are shown

  10. Exact solution for flow in a porous pipe with unsteady wall suction and/or injection

    Science.gov (United States)

    Tsangaris, S.; Kondaxakis, D.; Vlachakis, N. W.

    2007-10-01

    This paper presents an extension of the exact solution of the steady laminar axisymmetric flow in a straight pipe of circular cross section with porous wall, given by R.M. Terrill, to the case of unsteady wall injection and/or suction. The cases of the pulsating parabolic profile and of the developed pulsating flow are investigated as examples. The pulsating flow in porous ducts has many applications in biomedical engineering and in other engineering areas.

  11. Finite Element Limit Pressures for Circumferential Through-Wall Cracks in the Interface between Elbow and Pipe

    International Nuclear Information System (INIS)

    Jang, Yoon-Young; Han, Tae-Song; Huh, Nam-Su; Jeong, Jae-Uk

    2014-01-01

    Among integrity assessment method based on a fracture mechanics concept for piping system, a limit load method is one of the important way to predict a maximum load carrying capacity in the materials with high ductility in the sense that it is used to either assess directly structural integrity of pipe based on fully plastic fracture mechanics or calculate elasticplastic fracture mechanics parameters based on reference stress concept. In nuclear power plants, piping system often involves elbows welded to straight pipe. Since welded regions are vulnerable to cracking, it is important to predict an accurate limit load for pipes with a crack in the interface between elbows and attached pipes. However, although extensive works have been made for developing limit analysis methods for cracked pipes, they were mainly for straight pipes. Recently, limit moment solutions for elbow that is attached to straight pipe with a circumferential through-wall crack(TWC) in the interface were proposed, whereas limit pressure for this geometry is not suggested yet. In this context, plastic limit pressures of circumferential TWCs between elbow and straight pipe were calculated in the present study considering geometric parameters such as an elbow curvature, a pipe size and a crack length. In the present study, the FE plastic limit analyses for circumferential TWC in the interface between elbow and pipe under internal pressure were conducted based on elastic perfectly plastic assumption. Based on the present FE results, it is found that plastic limit pressures of straight pipes with circumferential TWC are not appropriate for predicting plastic limit pressures of circumferential TWC in the interface between elbow and pipe for shorter crack length

  12. Applicability of ANSYS ELBOW290 element for flexibility calculation of tight radius bends on feeder pipes in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X., E-mail: Xuan.Zhang@candu.com [Candu Energy Inc, Mississauga, ON (Canada)

    2015-07-01

    A curved pipe element, ELBOW290, became available in ANSYS 12. This element was developed based on a simplified shell theory, and maintains the ability to capture cross-sectional deformations of elbows. Numerical testing on the applicability of this element for the flexibility calculation of the tight radius bends in CANDU reactors is carried out to determine the usability of this element in completing stress analyses for feeder pipes. Comparisons are made between the ELBOW290 and the shell element for various feeder bend types found in domestic and overseas CANDU reactors. The comparisons show that the ELBOW290 element is suitable for calculating the flexibility of the tight radius bends. (author)

  13. Experimental stress analysis of four machined 10-in. NPS piping elbows with specified geometric distortions

    International Nuclear Information System (INIS)

    Moore, S.E.; Dodge, W.G.; Bolt, S.E.

    1983-09-01

    Four specially fabricated nominal 10-in. NPS, 90 0 , long-radius, schedule 40, carbon-steel piping elbows, welded to short lengths of straight pipe, were stress analyzed both experimentally and analytically. One elbow had a circular cross section and a uniform wall thickness, while the other three had either a circular or elliptical cross section with either a uniform or variable wall thickness. The objectives of the tests were primarily to study the influence of out of roundness and wall-thickness variations on the stresses in piping elbows under internal pressure and/or applied moment loadings. Analytical studies were made to isolate the various effects by comparing the experimental data with theoretical baseline solutions. Results of the studies showed that analytical solutions based on no-end-effects (NEE) theory capture the major characteristics of the stress distributions for elbows loaded with pressure and/or in-plane, out-of-plane, or torsional moment loadings. Of the four second-order effects addressed in this study, and effects had the most influence on the stresses, followed in order by out of roundness, wall-thickness variations, and pressure-moment interactions. Of these, the only significant increase in maximum stresses above those predicted by NEE theory was for the case of out of roundness with internal-pressure loading

  14. Gage for gas flow measurement especially in gas-suction pipes

    International Nuclear Information System (INIS)

    Renner, K.; Stegmanns, W.

    1978-01-01

    The gage utilizes the differential pressure given by a differential pressure producer to generate, in a bypass, a partial gas flow measured by means of a direct-reading anemometer of windmill type. The partial gas flow is generated between pressure pick-up openings in the gas-suction pipe in front of a venturi insert and pressure pick-up openings at the bottleneck of the venturi insert. The reading of the anemometer is proportional to the main gas flow and independent of the variables of state and the properties of the gases to be measured. (RW) [de

  15. Simplified inelastic (plastic and creep) analysis of pipe elbows subjected to inplane and out-of-plane bending

    International Nuclear Information System (INIS)

    Mello, R.M.; Scheller, J.D.

    1975-01-01

    The inelastic analysis of elbows typical of use in Liquid Metal Fast Reactor piping systems is described. Detailed information on stresses, plastic and creep strains, and deformations throughout the elbow bodies resulting from elastic/plastic, elastic/plastic/creep, and elastic/plastic-creep/relaxation material behavior was obtained for the cases of applied inplane and out-of-plane moment loading on the elbows. Some conclusions are made concerning the nature of the resulting stresses in the elbows. The simplified pipe-bend element in the MARC nonlinear finite element program is used as the analytical tool. This element permits nonlinear analysis of piping elbows and pipeline systems at realistic cost. 16 refs

  16. Pipe elbow stiffness coefficients including shear and bend flexibility factors for use in direct stiffness codes

    International Nuclear Information System (INIS)

    Perry, R.F.

    1977-01-01

    Historically, developments of computer codes used for piping analysis were based upon the flexibility method of structural analysis. Because of the specialized techniques employed in this method, the codes handled systems composed of only piping elements. Over the past ten years, the direct stiffness method has gained great popularity because of its systematic solution procedure regardless of the type of structural elements composing the system. A great advantage is realized with a direct stiffness code that combines piping elements along with other structural elements such as beams, plates, and shells, in a single model. One common problem, however, has been the lack of an accurate pipe elbow element that would adequately represent the effects of transverse shear and bend flexibility factors. The purpose of the present paper is to present a systematic derivation of the required 12x12 stiffness matrix and load vectors for a three dimensional pipe elbow element which includes the effects of transverse shear and pipe bend flexibility according to the ASME Boiler and Pressure Vessel Code, Section III. The results are presented analytically and as FORTRAN subroutines to be directly incorporated into existing direct stiffness codes. (Auth.)

  17. Automated numerical simulation of cracked plates, pipes and elbows

    International Nuclear Information System (INIS)

    Reddy, Babu; Sreehari Kumar, B.; Bhate, S.R.; Kushwaha, H.S.

    2008-01-01

    In the nuclear industry, piping components are one of the key elements participating in its operation. Integrity of structural tubes and pipes plays a major role in nuclear power plants. The ideal procedure to ensure this aspect would be to conduct experimental studies on pilot/test specimens. However, it may not always be feasible to carry out the experimental investigation, as it requires pre-requisite infrastructure which may not be economically viable. This makes it imperative to conduct numerical simulations of the same particularly in the study of presence of cracks in the critical components. While performing the effect of cracks, the quality of the finite element mesh nearer to the crack tip plays a critical role while estimating J-integral value. The designer is often familiar with design methodology only and he obviously requires a convenient and reliable numerical tool to model and perform the analysis. In this context, an effort has been made in NISA, the general purpose finite element software, to automate the generation of FE meshes for a set of pre-defined components with different crack configurations. To simplify the procedure of FE mesh generation, analysis, and post processing, a graphical user interface (GUI) has been developed accordingly. This paper discusses the automated numerical simulation of plates and pipes with different crack configurations. This simulation software is also designed to help parametric study of cracked pipes. (author)

  18. The modal analysis of a pipe elbow with realistic boundary conditions

    International Nuclear Information System (INIS)

    Carneiro, J.O.; Melo, F.J.Q. de; Rodrigues, J.F.D.; Lopes, H.; Teixeira, V.

    2005-01-01

    A vibration analysis for the determination of the natural frequencies and the associated eigenmodes of a pipe elbow with end-flanges or tangent terminations was performed. A numerical investigation of this problem was achieved with a semi-analytic definition finite ring element and a commercial finite element code. To assess the accuracy of the numerical solution for the elbow vibration, an experimental modal analysis was performed on a curved and on a straight pipe. The responses were processed by a data acquisition system which performs a fast Fourier transform on the time histories to convert them from a time to frequency domain, these leading to the extraction of natural frequencies and mode shapes associated with the test-specimen. The results were compared with the corresponding ones from the numerical approach and discussion about the results completes the paper

  19. Review of the analysis methods of surface crack for straight pipe and elbow

    International Nuclear Information System (INIS)

    Kim, H. S.; Jang, Y. S.; Jin, T. E.

    1999-01-01

    The objective of this paper is to find out optimum EPFM analysis methods of straight pipe and elbow by comparison of load-carrying capacities. To do this, analytical and finite element analyses were performed and then these results compared with the ones in the literatures and experimental data to verify the validity of the analysis results. Comparison results showed that NSC method for straight pipe and SC.ELB2 method for elbow were appropriate ones among analytical methods except FEM to predict load-carrying capacities. However, the trend of prediction results scattered according to the analysis conditions such as geometry and material as well as analytical methods, it is necessary for cautious application of the analytical methods

  20. Experimental analysis of austenitic stainless steel straight pipes and elbows under pressure and moment loadings

    International Nuclear Information System (INIS)

    Barrou, A.; Prost, J.P.; Delidais, M.

    1983-08-01

    In order to avoid undesirable plastic response in PWR primary system components, tests were performed on 1/10 scale pipes and elbows made from AISI 316 austenitic stainless steel. L/D ratios were from 0.56 to 4.50 mm, arc angles of elbows were 30 0 , 45 0 , 60 0 and 90 0 . Pipes were subjected to bending moments at 3 internal pressure levels. They were tested to determine the mode of failure and served as a reference for elbows. Elbows were subjected to in-plane (closing and opening) and out-of-plane bending moments, at 3 pressure and 2 temperature levels. During these tests, loadings and displacements of components were monitored. Ovalisation of sections was measured regularly. The experimental plastic collapse moment corresponding to excessive deformation was compared to the maximum allowable moment under Design conditions. The experimental plastic instability moment considered as a limit for functional capability was compared to the maximum allowable moment for level C and D service limits

  1. Inelastic finite element analysis of a pipe-elbow assembly (benchmark problem 2)

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, H P [Internationale Atomreaktorbau GmbH (INTERATOM) Bergisch Gladbach (Germany); Prij, J [Netherlands Energy Research Foundation (ECN) Petten (Netherlands)

    1979-06-01

    In the scope of the international benchmark problem effort on piping systems, benchmark problem 2 consisting of a pipe elbow assembly, subjected to a time dependent in-plane bending moment, was analysed using the finite element program MARC. Numerical results are presented and a comparison with experimental results is made. It is concluded that the main reason for the deviation between the calculated and measured values is due to the fact that creep-plasticity interaction is not taken into account in the analysis. (author)

  2. J simplified assessment for cracked pipes and elbows in the RSE-M code

    International Nuclear Information System (INIS)

    Delliou, P.L.; Sermage, J.-P.; Gilles, P.; Marie, S.; Kayser, Y.; Barthelet, B.

    2005-01-01

    RSE-M Code provides rules and requirements for in-service inspection of French Pressurized Water Reactor power plant components. Non mandatory guidance is given in the Code for defect assessment in a wide range of configurations: surface cracked pipes and elbows under pressure, moment and thermal loading. The Code provides influence coefficients to calculate stress intensity factors in pipes and elbows containing semi-elliptical surface defects (circumferential or longitudinal). The J assessment method is based on the reference stress concept with two options for reference loads evaluation: 'CEP elastic plastic stress' and 'CLC modified limit load'. This paper presents an overview of all the formulations and namely the case of pipe-to elbow junctions. The paper provides also a description of the very large data base of 2D and 3D J elastic-plastic finite element calculations performed to establish and validate the formulations. Finally an applicability domain of the methods is given ensuring a conservative prediction of J. (authors)

  3. A Study on Effect of Local Wall Thinning in Carbon Steel Elbow Pipe on Elastic Stress Concentration

    International Nuclear Information System (INIS)

    Kim, Jong Sung; Seo, Jae Seok

    2009-01-01

    Feeder pipes that connect the inlet and outlet headers to the reactor core in CANDU nuclear power plants are considered as safety Class 1 piping items. Therefore, fatigue of feeder pipes should be assessed at design stage in order to verify structural integrity during design lifetime. In accordance with the fatigue assessment result, cumulative usage factors of some feeder pipes have significant values. The feeder pipes made of SA-106 Grade B or C carbon steel have some elbows and bends. An active degradation mechanism for the carbon steel outlet feeder piping is local wall thinning due to flow-accelerated corrosion. Inspection results from plants and metallurgical examinations of removed feeders indicated the presence of localized thinning in the vicinity of the welds in the lower portion of outlet feeders, such as Grayloc hub-to-bend weld, Grayloc hub-to-elbow weld, elbow-to-elbow, and elbow-to-pipe weld. This local wall thinning can cause increase of peak stress due to stress concentration by notch effect. The increase of peak stress results in increase of cumulative usage factor. However, present fatigue assessment doesn't consider the stress concentration due to local wall-thinning. Therefore, it is necessary to assess the effect of local wall thinning on stress concentration. This study investigates the effect of local wall thinning geometry on stress concentration by performing finite element elastic stress analysis

  4. Application of failure assessment diagram methods to cracked straight pipes and elbows

    International Nuclear Information System (INIS)

    Ainsworth, R.A.; Gintalas, M.; Sahu, M.K.; Chattopadhyay, J.; Dutta, B.K.

    2016-01-01

    This paper reports fracture assessments of large-scale straight pipes and elbows of various pipe diameters and crack sizes. The assessments estimate the load for ductile fracture initiation using the failure assessment diagram method. Recent solutions in the literature for stress intensity factor and limit load provide the analysis inputs. An assessment of constraint effects is also performed using recent solutions for elastic T-stress. It is found that predictions of initiation load are close to the experimental values for straight pipes under pure bending. For elbows, there is generally increased conservatism in the sense that the experimental loads are greater than those predicted. The effects of constraint are found not to be a major contributor to the initiation fracture assessments but may have some influence on the ductile crack extension. - Highlights: • This paper presents assessments of the loads for ductile fracture initiation in 21 large-scale piping tests. • Modern stress intensity factor and limit load solutions were used for standard failure assessment diagram methods. • This leads to generally accurate assessments of the loads for ductile crack initiation. • The effects of constraint are found not to be a major contributor to the initiation fracture assessments.

  5. The effect of load-controlled bending load on the failure pressure of wall-thinned pipe elbows

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Yoon, Min Soo; Park, Chi Yong

    2013-01-01

    Highlights: • We evaluated bending load effect on the failure pressure of wall-thinned pipe elbows. • Burst tests were conducted on real-scale elbow specimens with local wall thinning. • The tests were performed under combined pressure and load-controlled bending. • Load-controlled bending reduced the failure pressure of wall-thinned elbows. • Bending load effect was significant for opening-mode and intrados wall-thinning case. - Abstract: In this research, burst tests were conducted on real-scale elbow specimens, each with an artificial local wall-thinning defect, under combined internal pressure and constant in-plane bending load, as well as under simple internal pressure, to evaluate the effect of load-controlled bending load on the failure pressure of locally wall-thinned pipe elbows. Ninety-degree, 65A Schedule 80 elbows, with wall-thinning defects in the intrados and extrados, were used as specimens. The bending loads were in-plane opening- and closing-mode bending, applied in load-control mode. The results clearly indicated that a load-controlled in-plane bending load reduced the failure pressure of wall-thinned pipe elbows, in contrast to observations previously made under displacement-controlled bending conditions. The effect of the bending load was more significant for opening-mode than for closing-mode bending, regardless of the wall-thinning location in the elbow. Also, the effect was greater when the wall-thinning defect was located in the intrados region of the elbow, rather than the extrados region. Existing models that have been proposed to evaluate the failure of wall-thinned elbows under simple internal pressure conservatively predicted the failure pressure of elbows subjected to a combined internal pressure and load-controlled bending load

  6. Numerical Study of Piping Limits for Suction Installation of Offshore Skirted Foundations an Anchors in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C. L.

    2010-01-01

    Skirted foundations and anchors have proved to be competitive solutions for various types of fixed offshore platforms, subsea systems and an attractive foundation alternative for offshore wind turbines. One main design challenge for skirted structures in sand is to penetrate the skirted deep enough...... to obtain the required capacity. In order to overcome the high penetration resistance in sand suction assisted penetration is needed. Suction installation may cause the formation of piping channels, which break down the hydraulic seal and prevent further installation. This paper presents a numerical study...... of failure limits during suction installation in respect to both homogenous and layered soil profile. A numerical flow analysis is performed to determine the hydraulic gradients developing in response to the suction applied, and the results are presented as simple closed form solutions useful for evaluation...

  7. Prediction of fracture parameters of circumferential through-wall cracks in the interface between an elbow and a pipe under internal pressure

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Youn Young; Huh, Nam Su [Dept. of Mechanical System Design Engineering, Seoul National Univ. of Science and Technology, Seoul (Korea, Republic of); Jeong, Jae Uk [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of)

    2016-09-15

    This paper provides plastic influence functions of GE/EPRI method for calculating J and Crack opening displacement (COD) of pipes with a circumferential Through-wall crack (TWC) in the interface between an elbow and a straight pipe by using 3-dimensional (3-D) elastic-plastic finite element analyses for Ramberg-Osgood (R-O) materials, in which internal pressure was considered as a loading condition. The proposed plastic influence functions are tabulated as a function of the pipe geometries, crack length and strain hardening exponent. In order to provide sufficient confidence for the proposed plastic influence functions, the estimation scheme using the proposed plastic influence functions for J and COD of cracked elbows was validated against FE results using R-O parameters for the SA312 TP316 stainless steel. Moreover, the predicted J and COD for elbows with a TWC in the interface between an elbow and a pipe by the proposed scheme were compared with those for cracked straight pipes to investigate the effect of the elbow geometries on crack behavior of elbows. One important point is that crack behaviors in the interface between an elbow and a straight pipe can be significantly different with those in straight pipes according to pipe thickness, crack length and bend radius of elbows. Thus, the proposed plastic influence functions can be useful to predict accurate J and COD for cracked elbows.

  8. Prediction of fracture parameters of circumferential through-wall cracks in the interface between an elbow and a pipe under internal pressure

    International Nuclear Information System (INIS)

    Jang, Youn Young; Huh, Nam Su; Jeong, Jae Uk

    2016-01-01

    This paper provides plastic influence functions of GE/EPRI method for calculating J and Crack opening displacement (COD) of pipes with a circumferential Through-wall crack (TWC) in the interface between an elbow and a straight pipe by using 3-dimensional (3-D) elastic-plastic finite element analyses for Ramberg-Osgood (R-O) materials, in which internal pressure was considered as a loading condition. The proposed plastic influence functions are tabulated as a function of the pipe geometries, crack length and strain hardening exponent. In order to provide sufficient confidence for the proposed plastic influence functions, the estimation scheme using the proposed plastic influence functions for J and COD of cracked elbows was validated against FE results using R-O parameters for the SA312 TP316 stainless steel. Moreover, the predicted J and COD for elbows with a TWC in the interface between an elbow and a pipe by the proposed scheme were compared with those for cracked straight pipes to investigate the effect of the elbow geometries on crack behavior of elbows. One important point is that crack behaviors in the interface between an elbow and a straight pipe can be significantly different with those in straight pipes according to pipe thickness, crack length and bend radius of elbows. Thus, the proposed plastic influence functions can be useful to predict accurate J and COD for cracked elbows

  9. Elastic-Plastic Fracture Mechanics Analyses for Circumferential Part-Through Surface Cracks at the Interface Between elbows and Pipes

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Oh, Chang Kyun; Kim, Yun Jae; Kim, Jong Sung; Jin, Tae Eun

    2007-01-01

    This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions for straight pipes

  10. Elastic-Plastic Fracture Mechanics Analyses For circumferential Part-through Surface Cracks At The Interface Between Elbows and Pipes

    International Nuclear Information System (INIS)

    Song, Tae Kwang; Kim, Yun Jae; Oh, Chang Kyun; Kim, Jong Sung; Jin, Tae Eun

    2007-01-01

    This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions for straight pipes

  11. Net-section limit moments and approximate J estimates for circumferential cracks at the interface between elbows and pipes

    International Nuclear Information System (INIS)

    Song, Tae-Kwang; Kim, Yun-Jae; Oh, Chang-Kyun; Jin, Tae-Eun; Kim, Jong-Sung

    2009-01-01

    This paper firstly presents net-section limit moments for circumferential through-wall and part-through surface cracks at the interface between elbows and attached straight pipes under in-plane bending. Closed-form solutions are proposed based on fitting results from small strain FE limit analyses using elastic-perfectly plastic materials. Net-section limit moments for circumferential cracks at the interface between elbows and attached straight pipes are found to be close to those for cracks in the centre of elbows, implying that the location of the circumferential crack within an elbow has a minimal effect on the net-section limit moment. Accordingly it is also found that the assumption that the crack locates in a straight pipe could significantly overestimate the net-section limit load (and thus maximum load-carrying capacity) of the cracked component. Based on the proposed net-section limit moment, a method to estimate elastic-plastic J based on the reference stress approach is proposed for circumferential cracks at the interface between elbows and attached straight pipes under in-plane bending.

  12. Strain measurements at the HDR-pipe-system under LOCA-load: Effects on elbows and displaced weldings

    International Nuclear Information System (INIS)

    Hunger, H.

    1985-01-01

    This paper characterizes some effects which have been detected during strain gauge measurements on a test piping with feed water check valve oscillating under blowdown-load. The ovalization of a pipe elbow subjected to in-plane-bending affects the connected straight pipe; this is shown by means of circumferential stresses. Very high LOCA-load produces plastic strain and changes the pipe dynamics. Artificial displaced welds increase the local strain but no defects have occurred. One example compares stresses from measurement and post-calculation. Moreover there are given some remarks on the optimization of the comparison of measurement and calculation. (orig.)

  13. Influence of fluid viscosity on vortex cavitation at a suction pipe inlet

    International Nuclear Information System (INIS)

    Ezure, Toshiki; Ito, Kei; Kamide, Hideki; Kameyama, Yuri; Kunugi, Tomoaki

    2016-01-01

    Cavitation is a highly important issue in various fluid machineries. In the design of an advanced loop-type sodium-cooled fast reactor in Japan, vortex cavitation is also a significant issue for the integrity of the reactor structure. Thus, an evaluation method for vortex cavitation is required. In this study, vortex cavitation at a single suction pipe inlet was studied under several different viscosity conditions including its transient behavior. The intermittent occurrence behaviors of vortex cavitation were grasped by visualization measurements. The experimental results showed that the influence of the kinematic viscosity was obvious under a high kinematic viscosity. However, the influence became smaller with decreasing kinematic viscosity. From these results, the non-dimensional circulation, which was defined as the ratio of the local circulation to the kinematic viscosity, was deduced as an evaluation parameter to estimate the influence of the kinematic viscosity. Cavitation factors at transition points from continuous occurrence to intermittent occurrences were also evaluated as representative points where vortex cavitation occurs. Then, the occurrences of vortex cavitation were expressed as a relation between the cavitation factor at transition points and the non-dimensional circulation. As a result, it was clarified that the cavitation factor at transition points increased linearly in relatively small non-dimensional circulation, while it was nearly constant in relatively large non-dimensional circulation. (author)

  14. A Study on the Instantaneous Turbulent Flow Field in a 90-Degree Elbow Pipe with Circular Section

    Directory of Open Access Journals (Sweden)

    Shiming Wang

    2016-01-01

    Full Text Available Based on the special application of 90-degree elbow pipe in the HTR-PM, the large eddy simulation was selected to calculate the instantaneous flow field in the 90-degree elbow pipe combining with the experimental results. The characteristics of the instantaneous turbulent flow field under the influence of flow separation and secondary flow were studied by analyzing the instantaneous pressure information at specific monitoring points and the instantaneous velocity field on the cross section of the elbow. The pattern and the intensity of the Dean vortex and the small scale eddies change over time and induce the asymmetry of the flow field. The turbulent disturbance upstream and the flow separation near the intrados couple with the vortexes of various scales. Energy is transferred from large scale eddies to small scale eddies and dissipated by the viscous stress in the end.

  15. Intuitional experiment and numerical analysis of flow characteristics affected by flow accelerated corrosion in elbow pipe system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Joon [School of Mechanical and Aerospace Engineering, Seoul National University, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Kim, Kyung Hoon, E-mail: kimkh@khu.ac.kr [Department of Mechanical Engineering, Kyung Hee University, Seochun 1, Yongin, Gyeonggi 446-701 (Korea, Republic of)

    2016-05-15

    Highlights: • Wall-thinning erosion of pipelines in plants leads to fatal accidents unexpectedly. • Flow Acceleration Corrosion (FAC) is a main reason of wall-thinning. • For industrial safety, it is necessary to verify the tendency of FAC. • We focused on local wall thinning by FAC with intuitional visualization experiment and numerical analysis in elbow pipe.

  16. Numerical Analysis of Pelton Nozzle Jet Flow Behavior Considering Elbow Pipe

    Science.gov (United States)

    Chongji, Zeng; Yexiang, Xiao; Wei, Xu; Tao, Wu; Jin, Zhang; Zhengwei, Wang; Yongyao, Luo

    2016-11-01

    In Pelton turbine, the dispersion of cylindrical jet have a great influence on the energy interaction of jet and buckets. This paper simulated the internal flow of nozzle and the downstream free jet flow at 3 different needle strokes. The nozzle model consists of the elbow pipe and the needle rod which supported by 4 ribs. Homogenous model and SST k-ω model were adopted to simulate the unsteady two-phase jet flow. The development of free flow, including a contraction process followed by an expansion process, was analysed detailed as well as the influence of the nozzle geometry on the jet flow pattern. The increase of nozzle opening results in a more dispersion jet, which means a higher hydraulic loss. Upstream bend and ribs induce the secondary flow in the jet and decrease the jet concentration.

  17. Collapse moment estimation by support vector machines for wall-thinned pipe bends and elbows

    International Nuclear Information System (INIS)

    Na, Man Gyun; Kim, Jin Weon; Hwang, In Joon

    2007-01-01

    The collapse moment due to wall-thinned defects is estimated through support vector machines with parameters optimized by a genetic algorithm. The support vector regression models are developed and applied to numerical data obtained from the finite element analysis for wall-thinned defects in piping systems. The support vector regression models are optimized by using both the data sets (training data and optimization data) prepared for training and optimization, and its performance verification is performed by using another data set (test data) different from the training data and the optimization data. In this work, three support vector regression models are developed, respectively, for three data sets divided into the three classes of extrados, intrados, and crown defects, which is because they have different characteristics. The relative root mean square (RMS) errors of the estimated collapse moment are 0.2333% for the training data, 0.5229% for the optimization data and 0.5011% for the test data. It is known from this result that the support vector regression models are sufficiently accurate to be used in the integrity evaluation of wall-thinned pipe bends and elbows

  18. Study on flow-induced vibration of large-diameter pipings in a sodium-cooled fast reactor. Influence of elbow curvature on velocity fluctuation field

    International Nuclear Information System (INIS)

    Ono, Ayako; Kimura, Nobuyuki; Kamide, Hideki; Tobita, Akira

    2010-02-01

    The main cooling system of Japan Sodium-cooled Fast Reactor (JSFR) consists of two loops to reduce the plant construction cost. In the design of JSFR, sodium coolant velocity is beyond 9m/s in the primary hot leg pipe with large-diameter (1.3m). The maximum Reynolds number in the piping reaches 4.2x10 7 . The hot leg pipe having a 90 degree elbow with curvature ratio of r/D=1.0, so-called 'short elbow', which enables a compact reactor vessel. In sodium cooled fast reactors, the system pressure is so low that thickness of pipings in the cooling system is thinner than that in LWRs. Under such a system condition in the cooling system, the flow-induced vibration (FIV) is concerned at the short elbow. The evaluation of the structural integrity of pipings in JSFR should be conducted based on a mechanistic approach of FIV at the elbow. It is significant to obtain the knowledge of the fluctuation intensity and spectra of velocity and pressure fluctuations in order to grasp the mechanism of the FIV. In this study, water experiments were conducted. Two types of 1/8 scaled elbows with different curvature ratio, r/D=1.0, 1.5, were used to investigate the influence of curvature on velocity fluctuation at the elbow. The velocity fields in the elbows were measured using a high speed PIV method. Unsteady behavior of secondary flow at the elbow outlet and separation flow at the inner wall of elbow were observed in the two types of elbows. It was found that the growth of secondary flow correlated with the flow fluctuation near the inside wall of the elbow. (author)

  19. The effect of bi-directional loading on fatigue assessment of pressurized piping elbows with local thinned areas

    International Nuclear Information System (INIS)

    Balan, C.; Redekop, D.

    2005-01-01

    An elastic-plastic finite element study is conducted to determine the effect of bi-directional loading on the fatigue characteristics of pressurized 90 deg. piping elbows with local thinned areas. The analysis is conducted on pressurized piping elbows considered previously in the literature, but analyzed only for in-plane loading. Considering also the out-of-plane loading the present analysis seeks to simulate simultaneous horizontal and vertical seismic actions. A validation study is first conducted in which the present results obtained for in-plane loading are compared with previous results. Comparisons are made for deformation patterns, hoop strain histories, and reaction forces. The relative in-plane to out-of-plane load intensities to be adopted for the combined loading case is determined next. Results considering bi-directional loadings are then found for the pressurized piping elbow for a total of 23 cases of local area thinning. Finally conclusions are drawn about the significance of considering the additional out-of-plane loading

  20. Condensation induced non-condensable accumulation in a non-vented horizontal pipe connected with an elbow and a vertical pipe

    International Nuclear Information System (INIS)

    Stevanovic, V.D.; Stosic, Z.V.; Stoll, U.

    2005-01-01

    In this paper the radiolytic gases (hydrogen and oxygen) accumulation is investigated numerically for the pipe geometry consisting of a horizontal pipe closed at one end, and connected via a downward directed elbow with a vertical pipe open at its bottom end. This configuration is a typical part of many pipeline systems or measuring lines. The steam inside the pipes is condensed due to heat losses to the surrounding atmosphere, the condensate is drained and the concentration of the remaining noncondensable radiolytic gases is increased. Three dimensional numerical simulations are performed with the thermal-hydraulic and physico-chemical code HELIO, especially developed for the simulation and analyses of radiolytic gases accumulation in pipelines. The HELIO code model is based on the mass, momentum and energy conservation equations for the gas mixture and wall condensate film flow, as well as on the transport equations for non-condensable diffusion and convection. At the liquid film surface, the phases are coupled through the no-slip velocity condition and the mass transfer due to steam condensation and non-condensable absorption and degassing. Obtained numerical results show the gas mixture and condensate liquid film flow fields. In case of here analyzed geometry, the gas mixture circulates in the elbow and the horizontal pipe due to buoyancy forces induced by concentration and related density differences. The circulation flow prevents the formation of the radiolytic gases concentration front. The non-condensable radiolytic gases are transported from the pipe through the open end by the mechanisms of diffusion and convection. The analyzed geometry is the same as in case of venting pipe mounted on the steam pipeline. The results are of practical importance since they show that radiolytic gases accumulation does not occur in the geometry of the venting pipes. (authors)

  1. Simulation of flow structure in the suction pipe of a hydroturbine by integral characteristics

    DEFF Research Database (Denmark)

    Kuibin, P.A.; Okulov, Valery; Pylev, I.M.

    2006-01-01

    Within the framework of a model of a twisted flow of an inviscid incompressible liquid, we solve the problem of determining the frequency and amplitude of oscillations caused by the precession of a helical vortex core in the suction tube of a hydroturbine from the specified integral characteristics...

  2. Large-eddy simulations of velocity and temperature fluctuations in hot and cold fluids mixing in a tee junction with an upstream straight or elbow main pipe

    International Nuclear Information System (INIS)

    Lu, T.; Attinger, D.; Liu, S.M.

    2013-01-01

    Highlights: • Temperature and velocity fluctuations in a tee junction are predicted using LES. • The numerical results are in good agreement with the experimental data. • Upstream elbow pipe has significant influence on those fluctuations. -- Abstract: Thermal striping resulting in thermal fatigue is an important safety issue for nuclear power plants. In this work, temperature and velocity fluctuations in hot and cold fluids mixing in a tee junction with the main pipe connected either to an upstream straight or elbow pipe have been numerically predicted using large-eddy simulations (LES) on the FLUENT platform with the assumption of fully-developed velocity at both main and branch pipe inlets. The numerical results for the case with an upstream straight pipe were found to be in reasonable agreement with the available experimental data. The reason for the small discrepancy between the numerical results and experimental data can be attributed to the turbulence velocity being 10% of the fully-developed velocity at the main and branch pipe inlets in the LES calculations, while in the experiments the turbulence velocity was about 10% of the average velocity upstream of the tee junction. The simulated normalized mean and root-mean square (RMS) temperatures and the velocities at both straight and elbow tees were then compared, as well as the power spectrum densities (PSD) of the temperature fluctuations. The elbow pipe upstream of the main pipe has a significant influence on the mixing, resulting in increased temperature and velocity fluctuations. The flow pattern of the elbow tee deviates from the wall jet due to the secondary flow in the upstream elbow pipe

  3. Life estimation of low-cycle fatigue of pipe elbows. Proposed criteria of low-cycle fatigue life under the multi-axial stress field

    International Nuclear Information System (INIS)

    Ando, Kotoji; Takahashi, Koji; Matsuo, Kazuya; Urabe, Yoshio

    2013-01-01

    Pipe elbows were important parts frequently used in the pipelines of nuclear power, thermal power and chemical plants, and their integrity needed to be assured under seismic loads and thermal stresses considering local wall thinning or complex stress distribution due to special configuration different from straight pipe. This article investigated in details elastic-plastic stress-strain state of pipe elbow using finite element analysis and clarified there existed high bi-axial stress field at side inner surface of pipe elbow axial cracks initiated. Bi-axial stress factor was around 0.6 for sound elbow and up to 0.95 for local wall thinning at crown. Fracture strain of 1.15 was reduced to around 0.15 for bi-axial stress factor from 0.6 to 0.9. Normalized fatigue life for bi-axial stress field (0.6 - 0.8) was largely reduced to around 15, 19 and 10% of fatigue life of uni-axial state dependent on material strength level. Proposed revised universal slopes taking account of multi-axial stress factor could explain qualitatively effects of strain range, internal pressure and ratchet strain (pre-strain) on low-cycle fatigue life of pipe elbow. (T. Tanaka)

  4. Simplified inelastic analysis of a 101.6-mm (4-in.), sched-10 elbow-pipe assembly subjected to an in-plane moment loading

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; McAfee, W.J.

    1979-01-01

    Results are reported for a simplified inelastic analysis of a thin-walled elbow pipe assembly tested under elastic-elastic-creep conditions. The analysis was performed as part of an IWGFR-sponsored Piping Benchmark Problem Effort being coordinated by Oak Ridge National Laboratory (ORNL). Comparisons are made between calculated and measured values of free-end displacement of the assembly and of outside surface strains at selected points in the elbow. The analyses overpredicted and deflections and surface strains by factors ranging from two to five. (author)

  5. The impact analysis of the connecting pipe length and diameter on the operation of a piston hybrid power machine of positive displacement with gas suction capacity

    Science.gov (United States)

    Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.

    2017-08-01

    The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.

  6. An advanced revised universal slope method for low cycle fatigue evaluation of elbow piping subjected to in-plane cyclic bending displacement

    International Nuclear Information System (INIS)

    Urabe, Yoshio

    2015-01-01

    In order to rationalize the low cycle fatigue evaluation of elbow piping subjected to in-plane cyclic bending displacement, an advanced revised universal slope method is proposed. In the proposed method, the coefficient of the first term of the fatigue life equation which resembles Manson's equation is expressed by parameters of the multi-axial degree, the tensile strength and the fracture strength. Also, the coefficient of the second term is expressed by the multi-axial degree, the fracture ductility and the minimum fracture ductility under the maximum multi-axial degree. Here equivalent strain range is used for the fatigue life estimation. The previously carried out pipe elbow test data were reanalyzed using the proposed method. As the result, the experimentally obtained fatigue lives had considerably good coincidences with the predicted fatigue lives by the proposed method. Application of the proposed method is also discussed. (author)

  7. Effect of local wall thinning on the collapse behavior of pipe elbows subjected to a combined internal pressure and in-plane bending load

    International Nuclear Information System (INIS)

    Kim, Jin-Weon; Na, Man-Gyun; Park, Chi-Yong

    2008-01-01

    The objective of this study was to investigate the effect of local wall thinning on the collapse behavior of pipe elbows subjected to a combined internal pressure and in-plane bending load. This study evaluated the global deformation behavior and collapse moment of the elbows, which contained various types of local wall-thinning defects at their intrados or extrados, using three-dimensional elastic-plastic finite element analysis. The analysis results showed that the global deformation behavior of locally wall-thinned elbows was largely governed by the mode of the bending and the elbow geometry rather than the wall-thinning parameters, except for elbows with considerably large and deep wall thinning that showed plastic instabilities induced by local buckling and plastic collapsing in the thinned area. The reduction in the collapse moment with wall-thinning depth was considerable when local buckling occurred in the thinned areas, whereas the effect of the thinning depth was small when ovalization occurred. The effects of the circumferential thinning angle and thinning length on the collapse moment of elbows were not major for shallow wall-thinning cases. For deeper wall-thinning cases, however, their effects were significant and the dependence of collapse moment on the axial thinning length was governed by the stress type applied to the wall-thinned area. Typically, the reduction in the collapse moment due to local wall thinning was clearer when the thinning defect was located at the intrados rather than the extrados, and it was apparent for elbows with larger bend radius

  8. Tennis elbow

    Science.gov (United States)

    Epitrochlear bursitis; Lateral epicondylitis; Epicondylitis - lateral; Tendonitis - elbow ... tennis or other racket sports, hence the name "tennis elbow." Backhand is the most common stroke to cause ...

  9. Elbow Fractures

    Science.gov (United States)

    ... is also an important factor when treating elbow fractures. Casts are used more frequently in children, as their risk of developing elbow stiffness is small; however, in an adult, elbow stiffness is much more likely. Rehabilitation directed by your doctor is often used to ...

  10. Influence of elbow curvature on flow structure at elbow outlet under high Reynolds number condition

    Energy Technology Data Exchange (ETDEWEB)

    Ono, A., E-mail: ono.ayako@jaea.go.jp [Oarai Research and Development Center, Japan Atomic Energy Agency, Narita 4002, Oarai, Ibaraki 311-1393 (Japan); Kimura, N.; Kamide, H.; Tobita, A. [Oarai Research and Development Center, Japan Atomic Energy Agency, Narita 4002, Oarai, Ibaraki 311-1393 (Japan)

    2011-11-15

    In the design of Japan Sodium-cooled Fast Reactor (JSFR), coolant velocity is beyond 9 m/s in the primary hot leg pipe of 1.27 m diameter. The Reynolds number in the piping reaches 4.2 Multiplication-Sign 10{sup 7}. Moreover, a short-elbow is adopted in the hot leg pipe in order to achieve compact plant layout and to reduce plant construction cost. Therefore, the flow-induced vibration (FIV) arising from the piping geometry may occur in the short-elbow pipe. The FIV is due to the excitation source which is caused by the pressure fluctuation in the pipe. The pressure fluctuation in the pipe is closely related with the velocity fluctuation. As the first step of clarification of the FIV mechanism, it is important to grasp the mechanism of flow fluctuation in the elbow. In this study, water experiments with two types of elbows with different curvature ratios were conducted in order to investigate the interaction between flow separation and the secondary flow due to the elbow curvature. The experiments were conducted with the short-elbow and the long-elbow under Re = 1.8 Multiplication-Sign 10{sup 5} and 5.4 Multiplication-Sign 10{sup 5} conditions. The velocity fields in the elbows were measured using a high-speed Particle Image Velocimetry (PIV). The time-series of axial velocity fields and the cross-section velocity fields obtained by the high-speed PIV measurements revealed the unsteady and complex flow structure in the elbow. The flow separation always occurred in the short-elbow while the flow separation occurred intermittently in the long-elbow case. The circumferential secondary flows in clockwise and counterclockwise directions flowed forward downstream of reattachment point alternately in both elbows.

  11. Elbow Pain

    Science.gov (United States)

    ... tear damage than are many other joints. Seek emergency care if you have: An obvious deformity in ... http://www.mayoclinic.org/symptoms/elbow-pain/basics/definition/SYM-20050874 . Mayo Clinic Footer Legal Conditions and ...

  12. [Elbow dislocation].

    Science.gov (United States)

    de Pablo Márquez, B; Castillón Bernal, P; Bernaus Johnson, M C; Ibañez Aparicio, N M

    Elbow dislocation is the most frequent dislocation in the upper limb after shoulder dislocation. Closed reduction is feasible in outpatient care when there is no associated fracture. A review is presented of the different reduction procedures. Copyright © 2017 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Current state of low-cycle fatigue research based on multiaxial stress intensity and its challenges. Part 1. Focusing on low-cycle fatigue strength evaluation method of elbow piping subjected to in-plane cyclic bending displacement load

    International Nuclear Information System (INIS)

    Urabe, Yoshio

    2017-01-01

    The R and D of fatigue strength at multiaxial stress intensity is recognized to become extremely important in the future in terms of the elaboration of low-cycle fatigue evaluation of various structures including piping systems and reflection on those standards. This paper focuses on the evaluation method developed by the author, namely cumulative damage rule in consideration of multiaxial stress intensity, and explains the concept and the results of verification and evaluation. It also discusses the engineering problems of the current low cycle fatigue assessment technology that were clarified in the process of developing low-cycle fatigue assessment method based on multiaxial stress intensity. The conservative lifespan and somewhat more conservative actual lifetime of elbow piping can be estimated by the conventional 'revised universal slope method' and 'advanced revised universal slope method.' However, these are empirical rules, and the theoretical basis is not clear. From 'cumulative damage rule in consideration of multiaxial stress intensity,' the author calculated furthermore 'low cycle fatigue evaluation formula based on cumulative damage rule in consideration of multi-axial stress intensity,' and examined it. As a result, an evaluation formula that can reasonably assume the equivalent thermoplastic strain range could be obtained at half of the repeat count as targeted. Furthermore, at the stage where future high precision FEM analysis can be used, direct low-cycle fatigue life curve can be established. (A.O.)

  14. Elbow tendinopathy.

    Science.gov (United States)

    Pitzer, Michael E; Seidenberg, Peter H; Bader, Dov A

    2014-07-01

    Overuse injuries of the lateral and medial elbow are common in sport, recreational activities, and occupational endeavors. They are commonly diagnosed as lateral and medial epicondylitis; however, the pathophysiology of these disorders demonstrates a lack of inflammation. Instead, angiofibroblastic degeneration is present, referred to as tendinosis. As such, a more appropriate terminology for these conditions is epicondylosis. This is a clinical diagnosis, and further investigations are only performed to rule out other clinical entities after conventional therapy has failed. Yet, most patients respond to conservative measures with physical therapy and counterforce bracing. Corticosteroid injections are effective for short-term pain control but have not demonstrated long-term benefit. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Hydroponic Feed With Suction

    Science.gov (United States)

    Cox, William M.; Brown, Christopher S.; Dreschel, Thomas W.

    1994-01-01

    Placing nutrient solution under suction increases growth. Foam plug seals growing stem of plant, making it possible to maintain suction in nutrient liquid around roots. Jar wrapped in black tape to keep out light. Potential use in terrestrial applications in arid climates or in labor-intensive agricultural situations.

  16. Tennis elbow surgery

    Science.gov (United States)

    Lateral epicondylitis - surgery; Lateral tendinosis - surgery; Lateral tennis elbow - surgery ... Surgery to repair tennis elbow is often an outpatient surgery. This means you will not stay in the hospital overnight. You will be given ...

  17. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  18. Elbow Injuries and Disorders

    Science.gov (United States)

    ... Many things can make your elbow hurt. A common cause is tendinitis, an inflammation or injury to the tendons that attach muscle to bone. Tendinitis of the elbow is a sports injury, often from playing tennis or golf. You ...

  19. Nursemaid's Elbow (For Parents)

    Science.gov (United States)

    ... Parents Parents site Sitio para padres General Health Growth & Development Infections Diseases & Conditions Pregnancy & Baby Nutrition & Fitness Emotions & ... For Parents / Nursemaid's Elbow Print About Nursemaid's Elbow Toddlers and preschoolers are at risk for a common ...

  20. Failure Behavior of Elbows with Local Wall Thinning

    Science.gov (United States)

    Lee, Sung-Ho; Lee, Jeong-Keun; Park, Jai-Hak

    Wall thinning defect due to corrosion is one of major aging phenomena in carbon steel pipes in most plant industries, and it results in reducing load carrying capacity of the piping components. A failure test system was set up for real scale elbows containing various simulated wall thinning defects, and monotonic in-plane bending tests were performed under internal pressure to find out the failure behavior of them. The failure behavior of wall-thinned elbows was characterized by the circumferential angle of thinned region and the loading conditions to the piping system.

  1. Posttraumatic stiff elbow

    Directory of Open Access Journals (Sweden)

    Ravi Mittal

    2017-01-01

    Full Text Available Posttraumatic stiff elbow is a frequent and disabling complication and poses serious challenges for its management. In this review forty studies were included to know about the magnitude of the problem, causes, pathology, prevention, and treatment of posttraumatic stiff elbow. These studies show that simple measures such as internal fixation, immobilization in extension, and early motion of elbow joint are the most important steps that can prevent elbow stiffness. It also supports conservative treatment in selected cases. There are no clear guidelines about the choice between the numerous procedures described in literature. However, this review article disproves two major beliefs-heterotopic ossification is a bad prognostic feature, and passive mobilization of elbow causes elbow stiffness.

  2. End effects on elbows subjected to moment loadings

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Iskander, S.K.; Moore, S.E.

    1978-03-01

    End effects on elbows subjected to moment loading are investigated using the finite element program EPACA. Relatively simple but more accurate (than present Code) equations are developed and recommendation for an alternative Code method using these equations is presented. Data from EPACA on stresses at welds (elbow-to-pipe juncture) are presented. A simple equation is given for estimating the maximum stresses at the welds

  3. Fracture behavior of circumferentially surface-cracked elbows. Technical report, October 1993--March 1996

    International Nuclear Information System (INIS)

    Kilinski, T.; Mohan, R.; Rudland, D.; Fleming, M.

    1996-12-01

    This report presents the results from Task 2 of the Second International Piping Integrity Research Group (IPIRG-2) program. The focus of the Task 2 work was directed towards furthering the understanding of the fracture behavior of long-radius elbows. This was accomplished through a combined analytical and experimental program. J-estimation schemes were developed for both axial and circumferential surface cracks in elbows. Large-scale, quasi-static and dynamic, pipe-system, elbow fracture experiments under combined pressure and bending loads were performed on elbows containing an internal surface crack at the extrados. In conjunction with the elbow experiments, material property data were developed for the A106-90 carbon steel and WP304L stainless steel elbow materials investigated. A comparison of the experimental data with the maximum stress predictions using existing straight pipe fracture prediction analysis methods, and elbow fracture prediction methods developed in this program was performed. This analysis was directed at addressing the concerns regarding the validity of using analysis predictions developed for straight pipe to predict the fracture stresses of cracked elbows. Finally, a simplified fitting flaw acceptance criteria incorporating ASME B2 stress indices and straight pipe, circumferential-crack analysis was developed

  4. Fracture behavior of circumferentially surface-cracked elbows. Technical report, October 1993--March 1996

    Energy Technology Data Exchange (ETDEWEB)

    Kilinski, T.; Mohan, R.; Rudland, D.; Fleming, M. [and others

    1996-12-01

    This report presents the results from Task 2 of the Second International Piping Integrity Research Group (IPIRG-2) program. The focus of the Task 2 work was directed towards furthering the understanding of the fracture behavior of long-radius elbows. This was accomplished through a combined analytical and experimental program. J-estimation schemes were developed for both axial and circumferential surface cracks in elbows. Large-scale, quasi-static and dynamic, pipe-system, elbow fracture experiments under combined pressure and bending loads were performed on elbows containing an internal surface crack at the extrados. In conjunction with the elbow experiments, material property data were developed for the A106-90 carbon steel and WP304L stainless steel elbow materials investigated. A comparison of the experimental data with the maximum stress predictions using existing straight pipe fracture prediction analysis methods, and elbow fracture prediction methods developed in this program was performed. This analysis was directed at addressing the concerns regarding the validity of using analysis predictions developed for straight pipe to predict the fracture stresses of cracked elbows. Finally, a simplified fitting flaw acceptance criteria incorporating ASME B2 stress indices and straight pipe, circumferential-crack analysis was developed.

  5. End effects on elbows subjected to moment loadings

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1982-01-01

    So-called end effects for moment loadings on short-radius and long-radius butt welding elbows of various arc lengths are investigated with a view toward providing more accurate design formulas for critical piping systems. Data developed in this study, along with published information, were used to develop relatively simple design equations for elbows attached at both ends to long sections of straight pipe. These formulas are the basis for an alternate ASME Code procedure for evaluating the bending moment stresses in Class 1 nuclear piping (ASME Code Case N-319). The more complicated problems of elbows with other end conditions, e.g., flanges at one or both ends, are also considered. Comparisons of recently published experimental and theoretical studies with current industrial code design rules for these situations indicate that these rules also need to be improved

  6. Seepage Study for Suction Installation of Bucket Foundation in Different Soil Combinations

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna; Ibsen, Lars Bo; Clausen, Johan Christian

    2016-01-01

    Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force and addit......Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force...... around the bucket skirt. The exceedance of critical suction might lead to installation failure due to formation of piping channels, which break the hydraulic seal between the skirt and soil. The excess pore pressure arising due to applied suction changes the effective stress, hence the penetration...

  7. Elbow joint instability

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Henriksen, M G; Søjbjerg, Jens Ole

    1994-01-01

    The effect of simultaneous ulnar and radial collateral ligament division on the kinematics of the elbow joint is studied in a cadaveric model. Severance of the anterior part of the ulnar collateral ligament and the annular ligament led to significant elbow joint instability in valgus and varus...

  8. Elbow arthroplasty in perspective

    NARCIS (Netherlands)

    Heijink, A.

    2017-01-01

    This thesis focuses on the effect of biomechanical aspects of prosthesis design and outcome after radial head and total elbow arthroplasty. First, we examine the available evidence regarding the role of several unfavorable biomechanical conditions about the elbow in the development of

  9. Exposures of the elbow.

    Science.gov (United States)

    Axelrod, Terry S

    2014-11-01

    This article describes the basic bony, ligamentous, and neurologic anatomy of the structures about the elbow. The surgical exposures of the elbow joint are described, providing details of the various posterior, lateral, and medial approaches to the articular segments. Clinical applications describing the potential benefits of each surgical exposure are provided as examples. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Pulled elbow in children.

    Science.gov (United States)

    Yamanaka, Syunsuke; Goldman, Ran D

    2018-06-01

    Question Our practice is seeing children with relatively minor injuries to their elbows, with a history of "swinging" them when their hands are being held to cross the road. Nothing is usually found on a physical examination. I know that this is likely a "pulled elbow." Can we manage this in the clinic setting rather than sending the family to the emergency department? What would be the best course of action in the clinic setting? Answer Pulled elbow, also called nursemaid's elbow , is a radial head subluxation caused by axial traction or a sudden pull of the extended pronated arm, and it is a very common phenomenon. The practice of swinging children while holding their hands should be abandoned. In the case of pulled elbow, the child usually avoids moving the affected arm, holding it close to his or her body, without considerable pain, and no obvious swelling or deformity can be seen. While a fracture should be excluded, pulled elbow can usually be identified based on this presentation. The reduction procedure can easily be done in the office setting, with an 80% success rate and no complications. The hyperpronation maneuver (holding the elbow at 90° and then firmly pronating the wrist) to reduce pulled elbow has been found to be better than a supination-flexion maneuver (holding the elbow at 90° with one hand, supinating and flexing the elbow rapidly with the other) and should be exercised first. When 2 trials of reduction are unsuccessful, the child's arm should be splinted and the family should be sent for further evaluation. Copyright© the College of Family Physicians of Canada.

  11. A study of stress distribution in elbows mounted on stanchions

    International Nuclear Information System (INIS)

    Basavanhally, N.R.; Tonet, N.

    1983-01-01

    It is a common practice, both in the nuclear and power piping industry, to have integral attachments on piping to either form a restraint or an anchor. For small attachments, such as lugs, one can use the readily available methods (eg., ASME Code Case N-318) to evaluate the local stresses at these attachments. For elbows or curved pipes mounted on stanchions, the evaluation of local stresses is more complex. In the present analysis, a 3D finite element model was implemented to determine the stress intensification factor that can be applied to piping stress under internal pressure and in-plane bending type of loads. The analysis indicates that, for an internal pressure load, in-plane bending is generated. For such supports, a stress intensification factor should be used to account for the increased loads. The results also indicate that there is an optimum elbow to stanchion post radius ratio which should be used in designing such supports. (orig.)

  12. The elbow and its disorders

    International Nuclear Information System (INIS)

    Morrey, B.F.

    1985-01-01

    This book contains 49 chapters. Some of the chapter titles are: Diagnostic Radiographic Techniques of the Elbow; Radiography of the Pediatric Elbow; Muscle and Tendon Trauma: Tennis Elbow; Nerve Injuries; Tendon Injurires about the Elbow; and Ligamentous and Articular Injuries in the Athlete

  13. Finite element evaluation of erosion/corrosion affected reducing elbow

    International Nuclear Information System (INIS)

    Basavaraju, C.

    1996-01-01

    Erosion/corrosion is a primary source for wall thinning or degradation of carbon steel piping systems in service. A number of piping failures in the power industry have been attributed to erosion/corrosion. Piping elbow is one of such susceptible components for erosion/corrosion because of increased flow turbulence due to its geometry. In this paper, the acceptability of a 12 in. x 8 in. reducing elbow in RHR service water pump discharge piping, which experienced significant degradation due to wall thinning in localized areas, was evaluated using finite element analysis methodology. Since the simplified methods showed very small margin and recommended replacement of the elbow, a detailed 3-D finite element model was built using shell elements and analyzed for internal pressure and moment loadings. The finite element analysis incorporated the U.T. measured wall thickness data at various spots that experienced wall thinning. The results showed that the elbow is acceptable as-is until the next fuel cycle. FEA, though cumbersome, and time consuming is a valuable analytical tool in making critical decisions with regard to component replacement of border line situation cases, eliminating some conservatism while not compromising the safety

  14. Liquid-metal flow through a thin-walled elbow in a plane perpendicular to a uniform magnetic field

    International Nuclear Information System (INIS)

    Walker, J.S.

    1986-04-01

    This paper presents analytical solutions for the liquid-metal flow through two straight pipes connected by a smooth elbow with the same inside radius. The pipes and the elbow lie in a plane which is perpendicular to a uniform, applied magnetic field. The strength of the magnetic field is assumed to be sufficiently strong that inertial and viscous effects are negligible. This assumption is appropriate for the liquid-lithium flow in the blanket of a magnetic confinement fusion reactor, such as a tokamak. The pipes and the elbow have thin metal walls

  15. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear...... viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three...

  16. Excessive deformation and failure of straight parts and elbows

    International Nuclear Information System (INIS)

    Touboul, F.; Acker, D.

    1991-01-01

    The design rules for LMFBRs must cover the ranges of loading types and geometries wider than PWR Design Codes. Steam pipework does not differ between two reactor systems, but as far as sodium piping is concerned, usual PWR criteria may not be adequate. The LMFBR sodium piping is operated at high temperature and low pressure level. Moreover, these peculiar loadings require the geometrical characteristics completely different in the fact that the piping must be flexible but need not to be thick. For such piping components, the ultimate behavior depends much on the geometry. 170 experimental results on straight parts and 95 results on elbows were investigated. As for elbows, half of the tests were performed under in-plane closing moment. On the analysis of straight pipes and elbows, the experiments and the proposed expressions for the evaluation of collapse and instability moments are described, respectively. The application of the present study to the design rules and the criteria for various loading conditions are reported. It is difficult to experimentally distinguish between plastic instability and buckling. (K.I.)

  17. Posterolateral elbow joint instability

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole; Nielsen, K K

    1998-01-01

    Thirty-five osteoligamentous elbows were included in a study on the kinematics of posterolateral elbow joint instability during the pivot shift test (PST) before and after separate ligament cuttings in the lateral collateral ligament complex (LCLC). Division of the annular ligament or the lateral...... ulnar collateral ligament caused no laxity during the PST. Division of the lateral collateral ligament caused maximal laxity of 4 degrees and 23 degrees during forced PST in valgus and external rotation (supination), respectively. Cutting of the LCLC at the ulnar or the humeral insertion was necessary...... for any PST stressed elbow joint laxity to occur. Total division of the LCLC induced a maximal laxity of 7.9 degrees and 37 degrees during forced PST in valgus and external rotation (supination), respectively. This study suggests the lateral collateral ligament to be the primary soft tissue constraint...

  18. The thrower's elbow.

    Science.gov (United States)

    Patel, Ronak M; Lynch, T Sean; Amin, Nirav H; Calabrese, Gary; Gryzlo, Stephen M; Schickendantz, Mark S

    2014-07-01

    Overhead throwing activities expose the elbow to tremendous valgus stress, making athletes vulnerable to a specific constellation of injuries. Although baseball players, in particular pitchers, are the athletes affected most commonly, overhead throwing athletes in football, volleyball, tennis, and javelin tossing also are affected. The purpose of this review is to review the anatomy, biomechanics, pathophysiology, and treatment of elbow disorders related to overhead throwing athletes. Although focus is on management of ulnar collateral ligament injuries, all common pathologies are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Elbow mass flow meter

    Science.gov (United States)

    McFarland, A.R.; Rodgers, J.C.; Ortiz, C.A.; Nelson, D.C.

    1994-08-16

    The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity. 3 figs.

  20. Structural integrity assessment of piping components

    International Nuclear Information System (INIS)

    Kushwaha, H.S.; Chattopadhyay, J.

    2008-01-01

    Integrity assessment of piping components is very essential for safe and reliable operation of power plants. Over the last several decades, considerable work has been done throughout the world to develop a methodology for integrity assessment of pipes and elbows, appropriate for the material involved. However, there is scope of further development/improvement of issues, particularly for pipe bends, that are important for accurate integrity assessment of piping. Considering this aspect, a comprehensive Component Integrity Test Program was initiated in 1998 at Bhabha Atomic Research Centre (BARC), India. In this program, both theoretical and experimental investigations were undertaken to address various issues related to the integrity assessment of pipes and elbows. Under the experimental investigations, fracture mechanics tests have been conducted on pipes and elbows of 200-400 mm nominal bore (NB) diameter with various crack configurations and sizes under different loading conditions. Tests on small tensile and three point bend specimens, machined from the tested pipes, have also been done to evaluate the actual stress-strain and fracture resistance properties of pipe/elbow material. The load-deflection curve and crack initiation loads predicted by non-linear finite element analysis matched well with the experimental results. The theoretical collapse moments of throughwall circumferentially cracked elbows, predicted by the recently developed equations, are found to be closer to the test data compared to the other existing equations. The role of stress triaxialities ahead of crack tip is also shown in the transferability of J-Resistance curve from specimen to component. The cyclic loading and system compliance effect on the load carrying capacity of piping components are investigated and new recommendations are made. (author)

  1. Dynamic Behaviour of Suction Caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten

    to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary...... in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil...

  2. Management of tennis elbow

    Directory of Open Access Journals (Sweden)

    Chesterton LS

    2011-06-01

    Full Text Available Linda S Chesterton, Christian D Mallen, Elaine M HayArthritis Research UK Primary Care Centre, Primary Care Sciences, Keele University, Keele, Staffordshire, UKDate of preparation: April 21, 2011Conflict of interest: None declaredClinical question: What is the best treatment for tennis elbow?Results: Despite a wealth of research, there is no true consensus on the most efficacious management of tennis elbow especially for effective long-term outcomes. Corticosteroid injections do show large pain-relieving effects in the short term but are associated with risks of adverse events and long-term reoccurrence. Advice with a “wait and see” approach is recommended as the first-line treatment in primary care for most cases. In the medium term physiotherapy and or low-level laser therapy may be effective.Implementation: Rule out alternative diagnosis. Onward referral may be indicated if the condition does not resolve after 12 months.Keywords: tennis elbow, corticosteroids, physiotherapy, laser therapy

  3. Experimental study on occurrence-time ratio measurements of air entrainment in a suction sump

    International Nuclear Information System (INIS)

    Inagaki, K; Funaki, J; Hirata, K

    2009-01-01

    In order to get accurate measurements of air entrainment in a suction sump, we design some new simple bubble sensors, which can detect the existence of air bubbles inside a suction pipe with no disturbances by the sensors and with a fine spatial resolution. We force on an intermittency factor γ, that is, an occurrence-time ratio of the air entrainment, and compare the result by the present sensor with those by conventional two methods; namely, visual and auditory ones. As a result, we show the criteria which specify lower-accuracy conditions in the conventional methods. By the visual method, the accuracy of the γ becomes low, when γ is less than 0.05. By the auditory method, the accuracy of γ becomes low, when the submergence depth S of the suction pipe is close to the critical one S c .

  4. Geometric effects of 90-degree vertical elbows on local two-phase flow parameters

    International Nuclear Information System (INIS)

    Yadav, M.; Worosz, T.; Kim, S.

    2011-01-01

    This study presents the geometric effects of 90-degree vertical elbows on the development of the local two-phase flow parameters. A multi-sensor conductivity probe is used to measure local two-phase flow parameters. It is found that immediately downstream of the vertical-upward elbow, the bubbles have a bimodal distribution along the horizontal radius of the pipe cross-section causing a dual-peak in the profiles of local void fraction and local interfacial area concentration. Immediately downstream of the vertical-downward elbow it is observed that the bubbles tend to migrate towards the inside of the elbow's curvature. The axial transport of void fraction and interfacial area concentration indicates that the elbows promote bubble disintegration. Preliminary predictions are obtained from group-one interfacial area transport equation (IATE) model for vertical-upward and vertical-downward two-phase flow. (author)

  5. Impedance of flexible suction caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten; Andersen, Lars; Ibsen, Lars Bo

    2007-01-01

    The dynamic response of offshore wind turbines is affected by the properties of the foundation and the subsoil. The aim of this paper is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigations include evaluation of the vertical and cou...

  6. Stress indices and flexibility factors in thin elbows

    International Nuclear Information System (INIS)

    Berton, M.N.; Carbonnier, J.L.

    1983-01-01

    Usually piping calculations are done with a beam model. Ovalisation in elbows is taken into account by the means of flexibility factors and stress indices. This paper compares results from a beam model calculation with results from a 3 D shell model calculation. (codes TEDEL and TRICO from the CEA-SEMT System). The aim of this comparison is to study the validity of the stress indices and flexibility factors used in the beam model for several kinds of loading

  7. Scaled multiple holes suction tip for microneurosurgery; Technical note

    Directory of Open Access Journals (Sweden)

    Abdolkarim Rahmanian, Associate Professor of Neurosurgery

    2017-12-01

    Conclusion: The new suction tip permits easy and precise adjustment of suction power in microneurosirgical operations. Our scaled 3 and 4-hole suction tip is a simple and useful device for controlling the suction power during the microneurosurgeical procedures.

  8. Hydroforming Process for an Ultrasmall Bending Radius Elbow

    Directory of Open Access Journals (Sweden)

    Shangwen Ruan

    2018-01-01

    Full Text Available Bent pipes are widely used in automotive, aviation, and aerospace industries for delivering fluids. Parts having small relative bending radiuses are called elbows. However, fabricating a thin-walled elbow part using the simple bending process poses many challenges. One possible way to manufacture elbows is with the stamping-welding process. The major drawbacks of this method include the decline in sealing performance and the addition in weight attributed to the lap welding process. Tube hydroforming (THF is considered as a feasible solution to these problems. However, the forming process could be quite complex, and multistep forming is necessary. This study investigates the effects of preliminary processes on elbow forming such as bending, partition forming, and heat treatment and presents a high-performance optimized process design to achieve an ultrasmall radius elbow. The effects of multistep forming on the thickness distribution and the heat treatment on the microstructure have been evaluated. The results obtained from simulations show a reasonable agreement with those from the experiments.

  9. Suction is kid's play: extremely fast suction in newborn seahorses

    Science.gov (United States)

    Van Wassenbergh, Sam; Roos, Gert; Genbrugge, Annelies; Leysen, Heleen; Aerts, Peter; Adriaens, Dominique; Herrel, Anthony

    2009-01-01

    Ongoing anatomical development typically results in a gradual maturation of the feeding movements from larval to adult fishes. Adult seahorses are known to capture prey by rotating their long-snouted head extremely quickly towards prey, followed by powerful suction. This type of suction is powered by elastic recoil and requires very precise coordination of the movements of the associated feeding structures, making it an all-or-none phenomenon. Here, we show that newborn Hippocampus reidi are able to successfully feed using an extremely rapid and powerful snout rotation combined with a high-volume suction, surpassing that observed in adult seahorses. An inverse dynamic analysis shows that an elastic recoil mechanism is also used to power head rotation in newborn H. reidi. This illustrates how extreme levels of performance in highly complex musculoskeletal systems can be present at birth given a delayed birth and rapid development of functionally important structures. The fact that the head skeleton of newborn seahorses is still largely cartilaginous may not be problematic because the hydrodynamic stress on the rotating snout appeared considerably lower than in adult syngnathids. PMID:19324657

  10. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding...... soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients...... for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been...

  11. Numerical Study of Piping Limits for Installation of Large Diameter Buckets in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C.L.

    2010-01-01

    The bucket foundations, often referred as ‘suction caissons’, are large cylindrical structures, typically made in steel. The bucket foundations have the potential to be the cost-effective option for offshore wind turbines, if suction assisted penetration is employed. Suction installation may cause...... gradients developing in response to applied suction and the results are presented as simple closed form solutions useful for evaluation of suction thresholds against piping. These close form solutions are compared with large scale model test, performed in a natural seabed at a test site in Frederikshavn...

  12. Experimental analysis of ratchetting in elbows

    International Nuclear Information System (INIS)

    Acker, D.; Touboul, F.; Brouard, D.

    1991-01-01

    Despite of their apparent simplicity, elbows or curved tubes are one of the most tested and analyzed structures to the last years when a large effort has been done by CEA in the framework of the European Structural Integrity Working Group in order to reassess the RCC-MR (1985) piping design rules for elbows and straight parts (TOUBOUL (1988-1989)). It is impossible to mention all the authors and an extensive bibliography has been done by BENDJEDIDIA (1987). But nobody in our knowledge has taken care in experimental validation of design rules against ratcheting. With such objectives, an experimental test program has been performed at CEA, in order to appraise the design methods based on shakedown model like 3 S m rule used by ASME section III (1989) in USA or RCC-M (1988) in FRANCE, or based on the efficiency Diagram used by the french design code for Fast Breeder reactors RCC-MR (1985). The first results were published by M. BENDJEDIDIA (1987). They have been completed by additional tests and improved by a better material characterisation

  13. Guided wave propagation and scattering in pipeworks comprising elbows: Theoretical and experimental results

    International Nuclear Information System (INIS)

    Bakkali, M El; Lhémery, A; Baronian, V; Chapuis, B

    2015-01-01

    Elastic guided waves (GW) are used to inspect pipeworks in various industries. Modelling tools for simulating GW inspection are necessary to understand complex scattering phenomena occurring at specific features (welds, elbows, junctions...). In pipeworks, straight pipes coexist with elbows. GW propagation in the former cases is well-known, but is less documented in the latter. Their scattering at junction of straight and curved pipes constitutes a complex phenomenon. When a curved part is joined to two straight parts, these phenomena couple and give rise to even more complex wave structures. In a previous work, the SemiAnalytic Finite Element method extended to curvilinear coordinates was used to handle GW propagation in elbows, combined with a mode matching method to predict their scattering at the junction with a straight pipe. Here, a pipework comprising an arbitrary number of elbows of finite length and of different curvature linking straight pipes is considered. A modal scattering matrix is built by cascading local scattering and propagation matrices. The overall formulation only requires meshing the pipe section to compute both the modal solutions and the integrals resulting from the mode-matching method for computing local scattering matrices. Numerical predictions using this approach are studied and compared to experiments

  14. Hyperextension of the elbow joint

    DEFF Research Database (Denmark)

    Tyrdal, Stein; Olsen, Bo Sanderhoff

    1998-01-01

    According to an epidemiologic study (Scand J Med Sci 1996/ 6: 297-302) the mechanism of "handball goalie's elbow" may be forced hyperextension. The pathomechanics of hyperextension were studied in nine macroscopically normal male cadaver elbow joints. The mean age of the donors was 43.2 years...... of the medial collateral ligament; (3) occasional incomplete rupture of the lateral collateral ligament; and (4) small fragments of cartilage near the posterior edge of the ulna in one of the specimens. One or more of these lesions may be responsible for the symptoms in "handball goalie's elbow."...

  15. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  16. Calcific periarthritis of the elbow presenting as acute tennis elbow.

    Science.gov (United States)

    Jawad, F; Jawad, A S M

    2014-01-01

    A 28-year-old woman presented with sudden acute lateral epicondylitis. There was no history of preceding trauma or repetitive use of the arm. Because of the acute onset and signs of acute inflammation, an X-ray was arranged. The X-ray showed a hyperdense calcified elongated globule distal to the lateral epicondyle. A diagnosis of calcific periarthritis (calcium apatite) of the elbow was made. Calcific periarthritis has rarely been reported as a cause of acute elbow pain.

  17. A database to evaluate stress intensity factors of elbows with throughwall flaws under combined internal pressure and bending moment

    International Nuclear Information System (INIS)

    Chattopadhyay, J.; Dutta, B.K.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1993-01-01

    The advent of Leak-Before-Break (LBB) concept has replaced the traditional design basis event of Double Ended Guillotine Break (DEGB) in the design of primary heat transport (PHT) piping. The use of LBB concept requires postulation of largest credible cracks at highly stressed locations and demonstration of its stability under the maximum credible loading conditions. Stress analysis of PHT piping in nuclear power plants shows that the highly stressed piping components are normally elbows and branch tees. This necessitates detailed fracture mechanics evaluation of piping connections by computing Stress Intensity Factor (SIF) and/or J-integral. Simple analytical solutions for evaluation of SIF and J-integral for cracks in straight pipes are readily available in literature. However, the same type of solutions for elbows and tees are limited in open literature. In the present work, a database is generated to evaluate SIF for throughwall circumferential and longitudinal cracks under combined internal pressure and bending moment. Different parameters to characterise a cracked elbow are pipe factor (h), pipe bore radius to thickness ratio (r/t) and crack length. Another parameter (σ) is used to consider the relative magnitude of stresses due to internal pressure and remote bending moment. The database has been used to derive closed form expressions to evaluate SIF for elbow with cracks in terms of the aforementioned parameters. (author). 8 refs., 12 figs., 3 tabs

  18. Elbow arthroscopy: indications, techniques, outcomes, and complications.

    Science.gov (United States)

    Adams, Julie E; King, Graham J W; Steinmann, Scott P; Cohen, Mark S

    2015-01-01

    Elbow arthroscopy is a tool useful for the treatment of a variety of pathologies about the elbow. The major indications for elbow arthroscopy include débridement for septic elbow arthritis, synovectomy for inflammatory arthritis, débridement for osteoarthritis, loose body extraction, contracture release, treatment of osteochondral defects and selected fractures or instability, and tennis elbow release. To achieve favorable outcomes after elbow arthroscopy, the surgeon should be aware of contraindications, technical considerations, anatomic principles, and the need for proper patient positioning and portal selection. Elbow arthroscopy is an effective procedure for the treatment of inflammatory arthritis, osteoarthritis, and lateral epicondylitis.

  19. Suction caissons subjected to monotonic combined loading

    OpenAIRE

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to anal...

  20. Manufacture of piping components for nuclear power plants

    International Nuclear Information System (INIS)

    Bartecek, R.

    1983-01-01

    Hammer forging of hollow forging ingots, extrusion and elestroslag remelting may be used for the manufacture of large pipes. Technologies have been developed for the manufacture of elbows based on various types of forming. These procedures mainly include the hydraulic pressing of elbows from tubes and the pressing of symmetrical halves of elbows with subsequent welding. The hammer forging of valves, cross pieces, etc., has been replaced by forging and pressing. In order to prevent failures from occurring in the pipes during operation of nuclear power plants, pipes are being made of larger forgings, which reduces the number of welds. This improves the quality of the pipes, reduces production and assembly costs and is metal-saving. (E.S.)

  1. Suction caissons subjected to monotonic combined loading

    DEFF Research Database (Denmark)

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation...... for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to analyse the behaviour of suction caissons for offshore wind turbines subjected to combined loading. Finite element...

  2. Tennis elbow: associated psychological factors.

    Science.gov (United States)

    Aben, Aurelie; De Wilde, Lieven; Hollevoet, Nadine; Henriquez, Carlos; Vandeweerdt, Marc; Ponnet, Koen; Van Tongel, Alexander

    2018-03-01

    The etiology of tennis elbow is multifactorial. Overuse of the wrist extensors along with anatomic factors, such as flexibility problems, aging, and poor blood circulation, may play a role. This study investigated whether patients with tennis elbow have a different psychological profile compared with healthy controls. Patients with clinical signs of tennis elbow, consulting at the Ghent University Hospital between September 2015 and January 2017, were offered a paper-and-pencil questionnaire about Big Five personality traits, perfectionism, anxiety, depression, work satisfaction, and working conditions. Healthy controls in the same risk group were offered the same questionnaires. We recruited 69 patients (35 men, 34 women) and 100 controls (44 men, 56 women). Tennis elbow patients scored significantly lower on the personality traits extraversion and agreeableness. Men, in particular, scored significantly higher on perfectionism and were more likely to develop an anxiety disorder or a depression. Concerning work, patients indicated a significantly higher workload (especially men) and a significantly lower autonomy (especially women). Female patients also indicated less contact with colleagues. However, work satisfaction was relatively high in both groups. The results suggest that there is a relationship between complaints related to tennis elbow and psychological characteristics. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Effect of Reynolds number on flow and mass transfer characteristics of a 90 degree elbow

    Science.gov (United States)

    Fujisawa, Nobuyuki; Ikarashi, Yuya; Yamagata, Takayuki; Taguchi, Syoichi

    2016-11-01

    The flow and mass transfer characteristics of a 90 degree elbow was studied experimentally by using the mass transfer measurement by plaster dissolution method, the surface flow visualization by oil film method and stereo PIV measurement. The experiments are carried out in a water tunnel of a circular pipe of 56mm in diameter with a working fluid of water. The Reynolds number was varied from 30000 to 200000. The experimental result indicated the change of the mass transfer coefficient distribution in the elbow with increasing the Reynolds number. This phenomenon is further examined by the surface flow visualization and measurement of secondary flow pattern in the elbow, and the results showed the suggested change of the secondary flow pattern in the elbow with increasing the Reynolds numbers.

  4. Suction v. conventional curettage in incomplete abortion

    African Journals Online (AJOL)

    Suction v. conventional curettage in incomplete abortion. A randomised controlled trial. D. A. A. VERKUYL, C. A. CROWTHER .Abstract This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients ...

  5. PERBEDAAN PARAMETER KARDIOPULMONAL SETELAH TINDAKAN OPEN SUCTION

    Directory of Open Access Journals (Sweden)

    Muhamat Nofiyanto

    2013-12-01

    Full Text Available Background: Endotracheal suctioning is often performed by nurses and beneficial for critically ill patients. Suctioning is essential for removing secretions, maintaining airway patency and prevent unexpected complications. Open suctioning is performed by disconnecting patients with the ventilator. Suctioning not only removed secretions in the airway but also oxygen. Suctioning must be done correctly, safely, effectively and efficiently to prevent unexpected events in critically ill patients. Objective: This study aimed to determine differences on cardiopulmonary parameters after open suction in critically ill patients Methods: The study design was comparatif cross sectional analytic approach, using one group pre test and post test. The sample of the research amounted to 34 people, using purposive sampling technique. Catheter size 14 Fr on ETT number 7 mm used in this research to performed endotracheal suctioning. Cardiopulmonary parameters (Heart rate/ HR, respiratory rate/RR, oxygen saturation/SpO2, systolic blood pressure/ SBP and diastolic blood pressure/DBP measured by pulse oxymeter and bedside monitor before suction and immediately thereafter. Results: The results showed increase average heart rate 6.412 (from 106.62 into 113.03, Respiratory rate has increased 4.971 (from 20.62 into 25.59, SpO2 decreased 1.68 (from 99.09 into 97.41, and systolic blood pressure increased 5.71 (from 118.29 into 124.00 after performed open suction. The results of paired t-test statistical analysis (for RR, HR obtained a < 0.05 (0.000, whereas Wilcoxon statistical analysis (for SpO2, SBP obtained a < 0.05 (0.000 and 0.001. So it can be said that the difference cardiopulmonary parameters was statistically significant after perfomed open suction in critically ill patients.

  6. Dynamic behaviour of suction caissons

    Energy Technology Data Exchange (ETDEWEB)

    Liingaard, M.

    2006-12-15

    Offshore wind energy is a promising source of energy in the near future, and is rapidly becoming competitive with other power generating technologies. The continuous improvement in wind turbine technology means that the wind turbines have increased tremendously in both size and performance during the last 25 years. In order to reduce the costs, the overall weight of the wind turbine components is minimized, which means that the wind turbine structures become more flexible and thus more sensitive to dynamic excitation. Since the first resonance frequency of the modern offshore wind turbines is close to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary to account for the possibilities of dynamic effects of the soil-structure interaction. The aim of this thesis is to evaluate the dynamic soil-structure interaction of foundations for offshore wind turbines, with the intention that the dynamic properties of the foundation can be properly included in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil is simplified as a homogenous linear viscoelastic material. The dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequencydependent coefficients corresponding to the different degrees of freedom. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the

  7. Pipe crawlers: Versatile adaptations for real applications

    International Nuclear Information System (INIS)

    Hapstack, M.; Talarek, T.R.

    1990-01-01

    A problem at the Savannah River Site requires the unique application of a pipe crawler. A number of stainless steel pipes buried in concrete require ultrasonic inspection of the heat affected zones of the welds for detection of flaws or cracks. The paper describes the utilization of an inch-worm motion pipe crawler which negotiates a 90 degree reducing elbow with significant changes in diameter and vertical sections before entering the area of concern. After a discussion of general considerations and problem description, special requirements to meet the objectives and the design approach regarding the tractor, control system, instrument carriage, and radiation protection are discussed. 2 refs., 11 figs. (MB)

  8. Stresses in a curved pipe subject to an in-plane bending moment

    International Nuclear Information System (INIS)

    Hofmann, E.; Heeschen, U.

    1979-01-01

    The design of the KWU-primary component supports is mainly defined by the loads of the postulated pipe breaks. To estimate the maximum loading of a component support it is necessary to know the maximum in-plane bending moment (opening and closing) that can be transmitted by a pipe bend. Another reason for such information is that the displacements and distortions of the components cause higher stresses in elbows than in straight pipes. With a detailed knowledge of the deformation characteristic of a pipe bend an integrity analysis could be done without an expensive plastic system analysis. With this purpose in mind experiments were performed with straight pipes and pipe bends of different dimensions subject to in-plane bending moments. The experimental results give the ratio between the maximum transmittable moment of a pipe bend to that of a straight pipe or, the distortion of the end cross-sections and the flattening of the elbow cross-section. An attempt is made to derive simple expressions for estimating the behaviour at pipe elbows. Parallel to the experiments calculations were done for the straight pipe and elbow with a finite difference code with plastic capabilities. The results of the experiment and calculation are compared with the formulas of the ASME-Code section III subjection NB. (orig.)

  9. Pipe support

    International Nuclear Information System (INIS)

    Pollono, L.P.

    1979-01-01

    A pipe support for high temperature, thin-walled piping runs such as those used in nuclear systems is described. A section of the pipe to be suppported is encircled by a tubular inner member comprised of two walls with an annular space therebetween. Compacted load-bearing thermal insulation is encapsulated within the annular space, and the inner member is clamped to the pipe by a constant clamping force split-ring clamp. The clamp may be connected to pipe hangers which provide desired support for the pipe

  10. IPIRG programs - advances in pipe fracture technology

    International Nuclear Information System (INIS)

    Wilkowski, G.; Olson, R.; Scott, P.

    1997-01-01

    This paper presents an overview of the advances made in fracture control technology as a result of the research performed in the International Piping Integrity Research Group (IPIRG) program. The findings from numerous experiments and supporting analyses conducted to investigate the behavior of circumferentially flawed piping and pipe systems subjected to high-rate loading typical of seismic events are summarized. Topics to be discussed include; (1) Seismic loading effects on material properties, (2) Piping system behavior under seismic loads, (3) Advances in elbow fracture evaluations, and (4) open-quotes Realclose quotes piping system response. The presentation for each topic will be illustrated with data and analytical results. In each case, the state-of-the-art in fracture mechanics prior to the first IPIRG program will be contrasted with the state-of-the-art at the completion of the IPIRG-2 program

  11. IPIRG programs - advances in pipe fracture technology

    Energy Technology Data Exchange (ETDEWEB)

    Wilkowski, G.; Olson, R.; Scott, P. [Batelle, Columbus, OH (United States)

    1997-04-01

    This paper presents an overview of the advances made in fracture control technology as a result of the research performed in the International Piping Integrity Research Group (IPIRG) program. The findings from numerous experiments and supporting analyses conducted to investigate the behavior of circumferentially flawed piping and pipe systems subjected to high-rate loading typical of seismic events are summarized. Topics to be discussed include; (1) Seismic loading effects on material properties, (2) Piping system behavior under seismic loads, (3) Advances in elbow fracture evaluations, and (4) {open_quotes}Real{close_quotes} piping system response. The presentation for each topic will be illustrated with data and analytical results. In each case, the state-of-the-art in fracture mechanics prior to the first IPIRG program will be contrasted with the state-of-the-art at the completion of the IPIRG-2 program.

  12. Evaluation of fatigue-ratcheting damage of a pressurised elbow undergoing damage seismic inputs

    International Nuclear Information System (INIS)

    Dang Van, K.

    2000-01-01

    We present a simplified method to calculate the plastic ratchet of elbow-shaped pipes submitted to seismic loading and an internal pressure. This method is simplified in the sense that the value of the ratchet is obtained without the use of finite element method (FEM) calculations. Here we derive a formula and use it to evaluate the fatigue-ratcheting damage of an elbow. This approach is applicable to complex plastic response appropriately described by non-linear kinematics hardening, which is more realistic for stainless steel such as 316-L. (orig.)

  13. Orthotic devices for tennis elbow

    NARCIS (Netherlands)

    Struijs, P. A.; Smidt, N.; Arola, H.; van Dijk, C. N.; Buchbinder, R.; Assendelft, W. J.

    2001-01-01

    BACKGROUND: Lateral epicondylitis (tennis elbow) is a frequently reported condition. A wide variety of treatment strategies has been described. As of yet, no optimal strategy has been identified. OBJECTIVES: The objective of this review was to assess the effectiveness of orthotic devices for

  14. Eponyms in elbow fracture surgery

    NARCIS (Netherlands)

    Somford, Matthijs P.; Wiegerinck, Johannes I.; Hoornenborg, Daniël; van den Bekerom, Michel P. J.; Eygendaal, Denise

    2015-01-01

    Eponyms are common in medicine and in orthopaedic surgery. For future reference and historical considerations, we present common eponyms in elbow fracture surgery. We describe in short the biography of the name giver and give, where possible, the original description on which the eponym was based.

  15. Dynamic lateral response of suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara

    2017-01-01

    Deeper water installations of offshore wind turbines may be supported by jacket structures. This study investigates the dynamic response of suction caissons for jackets by analysing 3D finite element models in the frequency domain. The numerical modelling was firstly validated by analytical...... solutions for pile foundations. Groups of crucial dimensionless parameters related to the soil profile and the foundation geometry are identified and their effects on the response of suction caissons are studied. Static stiffness coefficients are presented in a form of mathematical formulas obtained...... by fitting the numerical results, pertaining foundations with different slenderness ratios and embedded in different soil profiles. Sensitivity of the dynamic impedances of suction caissons on the skirt length was showed in this study. Moreover, the results for the suction caissons indicated that the overall...

  16. Study on quality control measures of static casting main pipe in PWR nuclear power plant

    International Nuclear Information System (INIS)

    Jiang Zhenbiao; Li Guanying; Liu Zhicheng

    2013-01-01

    This study analyzes the main reasons which impact the quality of primary pipe static casting elbows in PWR-M310 nuclear power plant. The quality control measures are developed from the election and inspection of material, improving sand production and casting process, improving lean management of personnel. The static casting defects of primary pipe elbows for Fuqing Unit 1 and 2 were down to less than 50% of the former project. The quality of static casting for the primary pipe elbows was significantly improved. Moreover, the implementation saves human resources and financing to repair casting defects, and also helps to win the delivery schedule. The quality control measures are good reference for improving primary pipe casting process. This study provides valuable experience for further study of improving the quality of static casting for the primary pipe of PWR nuclear power plant. (authors)

  17. Computer simulation of LMFBR piping systems

    International Nuclear Information System (INIS)

    A-Moneim, M.T.; Chang, Y.W.; Fistedis, S.H.

    1977-01-01

    Integrity of piping systems is one of the main concerns of the safety issues of Liquid Metal Fast Breeder Reactors (LMFBR). Hypothetical core disruptive accidents (HCDA) and water-sodium interaction are two examples of sources of high pressure pulses that endanger the integrity of the heat transport piping systems of LMFBRs. Although plastic wall deformation attenuates pressure peaks so that only pressures slightly higher than the pipe yield pressure propagate along the system, the interaction of these pulses with the different components of the system, such as elbows, valves, heat exchangers, etc.; and with one another produce a complex system of pressure pulses that cause more plastic deformation and perhaps damage to components. A generalized piping component and a tee branching model are described. An optional tube bundle and interior rigid wall simulation model makes such a generalized component model suited for modelling of valves, reducers, expansions, and heat exchangers. The generalized component and the tee branching junction models are combined with the pipe-elbow loop model so that a more general piping system can be analyzed both hydrodynamically and structurally under the effect of simultaneous pressure pulses

  18. Total elbow arthroplasty in primary osteoarthritis of the elbow.

    Science.gov (United States)

    Kozak, T K; Adams, R A; Morrey, B F

    1998-10-01

    Primary osteoarthritis of the elbow is an infrequent condition typically managed by some form of debridement. There is no comment in the literature regarding prosthetic replacement for this condition. We report 5 patients (mean age, 68), with a minimum assessment of 3 years (range, 37-125 years) after total elbow arthroplasty. Complications in 4 patients included subluxation, fracture of a humeral component with particulate synovitis, heterotopic ossification, recurrent osteophyte formation, and transient ulnar neuropathy. Although revision was required in 2 of the 5, currently all experience had satisfactory outcomes. While replacement has proven ultimately to be a successful option for this high-demand patient group because of the high complication rate, we do not recommend replacement unless alternate operative options are deemed unacceptable.

  19. Flow induced vibrations of piping

    International Nuclear Information System (INIS)

    Gibert, R.J.; Axisa, F.

    1977-01-01

    In order to design the supports of piping systems, estimations of the vibrations induced by the fluid conveyed through the pipes are generally needed. For that purpose it is necessary to calculate the model parameters of liquid containing pipes. In most computer codes, fluid effects are accounted for just by adding the fluid mass to the structure. This may lead to serious errors. This paper presents a method to take into account these effects, by solving a coupled mechanical-acoustical problem: the computer code TEDEL of the C.E.A /D.E.M.T. System, based on the finite-elements method, has been extended to calculate simultaneously the pressure fluctuations in the fluid and the vibrations of the pipe. By this way the mechanical-acoustical coupled eigenmodes of any piping system can be obtained. These eigenmodes are used to determine the response of the system to various sources. Equations have been written in the hypohesis that acoustical wave lengths remain large compared to the diameter of the pipe. The method has been checked by an experiment performed on the GASCOGNE loop at D.E.M.T. The piping system under test consists of a tube with four elbows. The circuit is ended at each extremity by a large vessel which performs acoustical isolation by generating modes for the pressure. Excitation of the circuit is caused by a valve located near the downstream vessel. This provides an efficient localised broad band acoustical source. The comparison between the test results and the calculations has shown that the low frequency resonant characteristics of the pipe and the vibrational amplitude at various flow-rates can be correctly predicted

  20. Lateral epicondylitis of the elbow.

    Science.gov (United States)

    Tosti, Rick; Jennings, John; Sewards, J Milo

    2013-04-01

    Lateral epicondylitis, or "tennis elbow," is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Repetitive occupational or athletic activities involving wrist extension and supination are thought to be causative. The typical symptoms include lateral elbow pain, pain with wrist extension, and weakened grip strength. The diagnosis is made clinically through history and physical examination; however, a thorough understanding of the differential diagnosis is imperative to prevent unnecessary testing and therapies. Most patients improve with nonoperative measures, such as activity modification, physical therapy, and injections. A small percentage of patients will require surgical release of the extensor carpi radialis brevis tendon. Common methods of release may be performed via percutaneous, arthroscopic, or open approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Radiography of the pediatric elbow

    International Nuclear Information System (INIS)

    Hoffman, A.D.

    1985-01-01

    The ability to obtain adequate and appropriate radiographs of the elbow depends on a number of variables. Often the pattern and timing of the appearance of the numerous secondary ossifications centers at the elbow is a source of confusion to those who deal infrequently with children. To obtain diagnostic radiographs consistently requires well-maintained, modern equipment and technologists who pay careful attention to the details of radiographic technique. Radiology technicians are generally empathetic with the anxiety that a child (and an accompanying parent or guardian) may feel when confronted with the need to enter a radiology exposure room with its ominous appearing, bulky machinery. It is always helpful to reassure the patient gently that the examination is easy and will not cause any discomfort

  2. Posterolateral Rotatory Apprehension Test in Tennis Elbow.

    Science.gov (United States)

    Chanlalit, Cholawish; Phorkhar, Termphong

    2015-11-01

    Tennis elbow is a syndrome that commonly diagnosed in patient who comes with lateral elbow pain. Instability pain in tennis elbow patient was observed and reported in many previous literatures. Posterolateral rotatory apprehension test was proposed for diagnosis of posterolateral rotatory instability of elbow. However, no review literatures that studied about posterolateral rotatory apprehensions test in tennis elbow. To find out the relationship between posterolateral rotatory apprehension test and tennis elbow. There were 44 patients that were recruited in this study. We examined the posterolateral rotatory apprehension test in tennis elbow patients. The examination was done in our outpatient clinic from March 2012 to April 2012. The data was collected to find out the ratio of negative test in tennis elbow patient. The results from the posterolateral rotatory apprehension test were negative in 43 patients. The ratio of the negative test result was 98%. A result from posterolateral rotatory apprehension test should be negative in general tennis elbow patients. If this test is used in a tennis elbow patients who are suspected with hidden instability and the result is positive, further evaluation is strongly suggested.

  3. Pressurized water-reactor feedwater piping response to water hammer

    International Nuclear Information System (INIS)

    Arthur, D.

    1978-03-01

    The nuclear power industry is interested in steam-generator water hammer because it has damaged the piping and components at pressurized water reactors (PWRs). Water hammer arises when rapid steam condensation in the steam-generator feedwater inlet of a PWR causes depressurization, water-slug acceleration, and slug impact at the nearest pipe elbow. The resulting pressure pulse causes the pipe system to shake, sometimes violently. The objective of this study is to evaluate the potential structural effects of steam-generator water hammer on feedwater piping. This was accomplished by finite-element computation of the response of two sections of a typical feedwater pipe system to four representative water-hammer pulses. All four pulses produced high shear and bending stresses in both sections of pipe. Maximum calculated pipe stresses varied because the sections had different characteristics and were sensitive to boundary-condition modeling

  4. Dynamic stiffness of horizontally vibrating suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara; Cisternino, Michele

    2016-01-01

    The promising potential for offshore wind market is on developing wind farms in deeper waters with bigger turbines. In deeper waters the design foundation configuration may consist of jacket structures supported by floating piles or by suction caissons. Taking the soil-structure interaction effects...... into consideration requires the prior estimation of the dynamic impedances of the foundation. Even though numerous studies exist for piles, only limited number of publications can be found for suction caissons subjected to dynamic loads. Therefore, the purpose of this study is to examine the dynamic response...... of this type of foundation using the finite element method (FEM) to account for the interaction with the soil. 3D numerical models for both the soil and the suction caisson are formulated in a frequency domain. The response of the soil surrounding the foundation is considered linear viscoelastic...

  5. Pipe damping

    International Nuclear Information System (INIS)

    Ware, A.G.

    1985-01-01

    Studies are being conducted at the Idaho National Engineering Laboratory to determine whether an increase in the damping values used in seismic structural analyses of nuclear piping systems is justified. Increasing the allowable damping would allow fewer piping supports which could lead to safer, more reliable, and less costly piping systems. Test data from availble literature were examined to determine the important parameters contributing to piping system damping, and each was investigated in separate-effects tests. From the combined results a world pipe damping data bank was established and multiple regression analyses performed to assess the relative contributions of the various parameters. The program is being extended to determine damping applicable to higher frequency (33 to 100 Hz) fluid-induced loadings. The goals of the program are to establish a methodology for predicting piping system damping and to recommend revised guidelines for the damping values to be included in analyses

  6. 46 CFR 56.50-50 - Bilge and ballast piping.

    Science.gov (United States)

    2010-10-01

    ... or in the boiler or machinery space, including spaces in which oil settling tanks or oil pumping... pumping from and draining any watertight compartment except for ballast, oil and water tanks which have... the suction pipes. Efficient means shall be provided for draining water from all tank tops, other...

  7. The effect of elbow angle and external moment on load sharing of elbow muscles

    NARCIS (Netherlands)

    Praagman, M.; Chadwick, E.K.J.; van der Helm, F.C.T.; Veeger, H.E.J.

    2010-01-01

    To study elbow muscle load sharing we investigated the effect of external flexion-extension (FE) and pronation-supination (PS) moments and elbow angle on muscle activation and oxygen consumption (V̇O2).Two data sets were obtained. First, (n=6) electromyography (EMG) of elbow flexors (long and short

  8. Pipe damping

    International Nuclear Information System (INIS)

    Ware, A.G.; Arendts, J.G.

    1984-01-01

    A program has been developed to assess the available piping damping data, to generate additional data and conduct seperate effects tests, and to establish a plan for reporting and storing future test results into a data bank. This effort is providing some of the basis for developing higher allowable damping values for piping seismic analyses, which will potentially permit removal of a considerable number of piping supports, particularly snubbers. This in turn will lead to more flexible piping systems which will be less susceptible to thermal cracking, will be easier to maintain and inspect, as well as less costly

  9. Heat pipe

    International Nuclear Information System (INIS)

    Triggs, G.W.; Lightowlers, R.J.; Robinson, D.; Rice, G.

    1986-01-01

    A heat pipe for use in stabilising a specimen container for irradiation of specimens at substantially constant temperature within a liquid metal cooled fast reactor, comprises an evaporator section, a condenser section, an adiabatic section therebetween, and a gas reservoir, and contains a vapourisable substance such as sodium. The heat pipe further includes a three layer wick structure comprising an outer relatively fine mesh layer, a coarse intermediate layer and a fine mesh inner layer for promoting unimpeded return of condensate to the evaporation section of the heat pipe while enhancing heat transfer with the heat pipe wall and reducing entrainment of the condensate by the upwardly rising vapour. (author)

  10. Response of the primary piping loop to an HCDA

    International Nuclear Information System (INIS)

    Chang, Y.W.; Moneim, M.T.A.; Wang, C.Y.; Gvildys, J.

    1975-01-01

    The paper describes a method for analyzing the response of the primary piping loop that consists of straight pipes, elbows, and other components connected in series and subject to hypothetical core disruptive accident (HCDA) loads at both ends of the loop. The complete hydrodynamic equations in two-dimensions, that include both the nonlinear convective and viscous dissipation terms are used for the fluid dynamics together with the implicit ICE technique. The external walls of the pipes and components are treated as thin shells in which the analysis accounts for the membrane and bending strength of the wall, elastic-plastic material behavior, as well as large deformation under the effect of transient loading conditions. In the straight pipes, the flow is assumed to be axisymmetric; in the elbow regions, the two dimensions considered are the r and theta directions. The flow in the other components is also assumed to be axisymmetric; the components are modeled as a circular cylinder, in which the radius of the cylinder can be varied to conform with the outside shape of the component and the flow area inside can be changed independently from the outside shape. However, they must remain axially symmetric. The method is applied to a piping loop which consists of six elastic-plastic pipes and five rigid elbows connected in series and subjected to pressure pulses at both ends of the loop

  11. Overview of cooperative international piping benchmark analyses

    International Nuclear Information System (INIS)

    McAfee, W.J.

    1982-01-01

    This paper presents an overview of an effort initiated in 1976 by the International Working Group on Fast Reactors (IWGFR) of the International Atomic Energy Agency (IAEA) to evaluate detailed and simplified inelastic analysis methods for piping systems with particular emphasis on piping bends. The procedure was to collect from participating member IAEA countries descriptions of tests and test results for piping systems or bends (with emphasis on high temperature inelastic tests), to compile, evaluate, and issue a selected number of these problems for analysis, and to compile and make a preliminary evaluation of the analyses results. Of the problem descriptions submitted three were selected to be used: a 90 0 -elbow at 600 0 C with an in-plane transverse force; a 90 0 -elbow with an in-plane moment; and a 180 0 -elbow at room temperature with a reversed, cyclic, in-plane transverse force. A variety of both detailed and simplified analysis solutions were obtained. A brief comparative assessment of the analyses is contained in this paper. 15 figures

  12. Conceptual Design of Portable Filtered Air Suction Systems For Prevention of Released Radioactive Gas under Severe Accidents of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Yim, Man S.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    It becomes evident that severe accidents may occur by unexpected disasters such as tsunami, heavy flood, or terror. Once radioactive material is released from NPP through severe accidents, there are no ways to prevent the released radioactive gas spreading in the air. As a remedy for this problem, the idea on the portable filtered air suction system (PoFASS) for the prevention of released radioactive gas under severe accidents was proposed. In this paper, the conceptual design of a PoFASS focusing on the number of robot fingers and robot arm rods are proposed. In order to design a flexible robot suction nozzle, mathematical models for the gaps which represent the lifted heights of extensible covers for given convex shapes of pipes and for the covered areas are developed. In addition, the system requirements for the design of the robot arms of PoFASS are proposed, which determine the accessible range of leakage points of released radioactive gas. In this paper, the conceptual designs of the flexible robot suction nozzle and robot arm have been conducted. As a result, the minimum number of robot fingers and robot arm rods are defined to be four and three, respectively. For further works, extensible cover designs on the flexible robot suction nozzle and the application of the PoFASS to the inside of NPP should be studied because the radioactive gas may be released from connection pipes between the containment building and auxiliary buildings.

  13. Suction of MHD boundary layer flows

    International Nuclear Information System (INIS)

    Rao, B.N.

    1985-01-01

    The boundary layer growth with tensor electrical conductivity and the transpiration number has been examined using local nonsimilarity solutions method. It is found that suction will cause the increase in wall shearing stress and decrease in thicknesses of the boundary layer. (Auth.)

  14. Hydrodynamics of suction feeding in fish

    NARCIS (Netherlands)

    Muller, M.

    1983-01-01

    1. Suction feeding is the dominant way to obtain food in teleosts. Its high demands on structures due to the required velocities and forces leads to the expectation that a biophysical analysis will aid to reveal the adaptive significance of head and body structures related to this

  15. Pipe connector

    International Nuclear Information System (INIS)

    Sullivan, T.E.; Pardini, J.A.

    1978-01-01

    A safety test facility for testing sodium-cooled nuclear reactor components includes a reactor vessel and a heat exchanger submerged in sodium in the tank. The reactor vessel and heat exchanger are connected by an expansion/deflection pipe coupling comprising a pair of coaxially and slidably engaged tubular elements having radially enlarged opposed end portions of which at least a part is of spherical contour adapted to engage conical sockets in the ends of pipes leading out of the reactor vessel and in to the heat exchanger. A spring surrounding the pipe coupling urges the end portions apart and into engagement with the spherical sockets. Since the pipe coupling is submerged in liquid a limited amount of leakage of sodium from the pipe can be tolerated

  16. Trauma and sports injuries of the elbow

    NARCIS (Netherlands)

    Kodde, I.F.

    2016-01-01

    This thesis deals with current issues in the management of trauma and sports injuries of the elbow. Common sports injuries of the elbow involve ruptures of the distal biceps tendon and the ulnar collateral ligament. We evaluated one of the current thoughts, that the height of the radial bicipital

  17. Humeral windows in revision total elbow arthroplasty.

    Science.gov (United States)

    Peach, Chris A; Salama, Amir; Stanley, David

    2016-04-01

    The use of cortical windows for revision elbow arthroplasty has not previously been widely reported. Their use aids safe revision of a well fixed humeral prosthesis and can be used in the setting of dislocation, periprosthetic fracture or aseptic loosening of the ulnar component. We describe our technique and results of cortical windows in the distal humerus for revision elbow arthroplasty surgery.

  18. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  19. Nerve injuries do occur in elbow arthroscopy

    NARCIS (Netherlands)

    Hilgersom, Nick F. J.; van Deurzen, Derek F. P.; Gerritsma, Carina L. E.; van der Heide, Huub J. L.; Malessy, Martijn J. A.; Eygendaal, Denise; van den Bekerom, Michel P. J.

    2018-01-01

    The purpose is to create more awareness as well as emphasize the risk of permanent nerve injury as a complication of elbow arthroscopy. Patients who underwent elbow arthroscopy complicated by permanent nerve injury were retrospectively collected. Patients were collected using two strategies: (1) by

  20. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  1. Lateral epicondylitis of the elbow.

    Science.gov (United States)

    Vaquero-Picado, Alfonso; Barco, Raul; Antuña, Samuel A

    2016-11-01

    Lateral epicondylitis, also known as 'tennis elbow', is a very common condition affecting mainly middle-aged patients.The pathogenesis remains unknown but there appears to be a combination of local tendon pathology, alteration in pain perception and motor impairment.The diagnosis is usually clinical but some patients may benefit from additional imaging for a specific differential diagnosis.The disease has a self-limiting course of between 12 and 18 months, but in some patients, symptoms can be persistent and refractory to treatment.Most patients are well-managed with non-operative treatment and activity modification. Many surgical techniques have been proposed for patients with refractory symptoms.New non-operative treatment alternatives with promising results have been developed in recent years. Cite this article: Vaquero-Picado A, Barco R, Antuña SA. Lateral epicondylitis of the elbow. EFORT Open Rev 2016;1:391-397. DOI: 10.1302/2058-5241.1.000049.

  2. Erosion resistant elbow for solids conveyance

    Science.gov (United States)

    Not Available

    An elvow and process for fabrication for use in particulate material conveying comprising a curved outer pipe, a curved inner pipe having the same radius of curvature as the outer pipe, concentric with and internal to the outer pipe, comprising an outer layer comprised of a first material and an inner layer comprised of a second material wherein said first material is characterized by high erosion resistance when impinged by particulate material and wherein said second material is characterized by high tensile strength and flexibility, and an inner pipe supporting means for providing support to said inner pipe, disposed between said inner pipe and said outer pipe. 4 figures.

  3. Total elbow arthroplasty for primary osteoarthritis.

    Science.gov (United States)

    Schoch, Bradley S; Werthel, Jean-David; Sánchez-Sotelo, Joaquín; Morrey, Bernard F; Morrey, Mark

    2017-08-01

    Primary osteoarthritis of the elbow is a less common indication for total elbow arthroplasty (TEA). Higher complication rates in younger, active patients may offset short-term improvements in pain and function. The purpose of this study was to determine pain relief, functional outcomes, complications, and survival of TEA in this population. Between 1984 and 2011, 20 consecutive TEAs were performed for primary elbow osteoarthritis. Two patients died before the 2-year follow-up. Mean age at surgery was 68 years (range, 51-85 years). Outcome measures included pain, motion, Mayo Elbow Performance Score, satisfaction, complications, and reoperations. Mean follow-up was 8.9 years (range, 2-20 years). Three elbows sustained mechanical failures. Complications included intraoperative fracture (n = 2), wound irrigation and débridement (n = 1), bony ankylosis (n = 1), humeral loosening (n = 1), humeral component fracture (n = 1), and mechanical failure of a radial head component (n = 1). Fifteen elbows without mechanical failure were examined clinically. Pain improved from 3.6 to 1.5 (P  .05), with preoperative flexion contractures not improving. Mayo Elbow Performance Scores were available for 13 elbows without mechanical failure, averaging 81.5 points (range, 60-100 points); these were graded as excellent (n = 5), good (n = 2), and fair (n = 6). Subjectively, all patients without mechanical failure were satisfied. TEA represents a reliable surgical option for pain relief in patients with primary osteoarthritis. However, restoration of extension is not always obtained, indicating that more aggressive soft tissue releases or bony resection should be considered. Complications occurred in a large number of elbows, but mechanical failure was low considering the nature of this population and the length of follow-up. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Piping system damping data at higher frequencies

    International Nuclear Information System (INIS)

    Ware, A.G.

    1987-01-01

    Research has been performed at the Idaho National Engineering Laboratory (INEL) for the United States Nuclear Regulatory Commission (USNRC) to determine best-estimate damping values for dynamic analyses of nuclear piping systems excited in the 20 to 100 Hz frequency range. Vibrations in this frequency range are typical of fluid-induced transients, for which no formal pipe damping guidelines exist. The available data found in the open literature and the USNRC/INEL nuclear piping damping data bank were reviewed, and a series of tests on a straight 3-in. (76-mm) piping system and a 5-in. (127-mm) system with several bends and elbows were conducted as part of this research program. These two systems were supported with typical nuclear piping supports that could be changed from test to test during the series. The resulting damping values were ≥ those of the Pressure Vessel Research Committee (PVRC) proposal for unisulated piping. Extending the PVRC damping curve from 20 to 100 Hz at 3% of critical damping would give a satisfactory representation of the test data. This position has been endorsed by the PVRC Technical Committee on Piping Systems. 14 refs

  5. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1994-01-01

    It is approximately 10 years since the Third Edition of Heat Pipes was published and the text is now established as the standard work on the subject. This new edition has been extensively updated, with revisions to most chapters. The introduction of new working fluids and extended life test data have been taken into account in chapter 3. A number of new types of heat pipes have become popular, and others have proved less effective. This is reflected in the contents of chapter 5. Heat pipes are employed in a wide range of applications, including electronics cooling, diecasting and injection mo

  6. Studies on the behavior of part-through circumferential crack at intrados in elbows under in-plane bending moment

    International Nuclear Information System (INIS)

    Srivastava, A.; Prabhakaran, K.M.; Ghosh, A.K.

    2011-01-01

    Highlights: → Behavior of cracked elbows with part-through crack at intrados under bending moment is studied. → Some part of crack always opens and some part gets closed irrespective of mode of applied moment. → Fraction of the crack that opens basically decides the weakening effect of the cracked elbow. → Results will be useful for fracture studies and limit load estimation especially for LBB. - Abstract: This paper presents the behavior of part-through circumferential crack at intrados in elbows under in-plane bending moment. This is based on detailed non-linear (both material and geometric) finite element analysis performed on various sizes of elbows (generally used in piping industry), having different crack sizes. It is observed that some part of the crack always opens and some part gets closed irrespective of the mode of applied bending moment (opening/closing). The fraction of the crack that opens basically decides the weakening effect of the cracked elbow. It is observed that there is a threshold value of crack length and crack depth, before which no crack opening is observed under opening mode. Also as elbow becomes thinner, the threshold value of above two parameters increases. Quite interestingly, the part of crack which closes in opening mode opens under closing mode. The above mentioned study on the behavior of crack will be useful for fracture studies and limit load estimation especially when leak before break concept is to be employed.

  7. Osteochondrosis dissecans of the elbow.

    Science.gov (United States)

    Van Sonhoven, F; Geusens, E; Nijs, S

    2009-01-01

    This case shows a typical presentation of an osteochondrosis dissecans lesion on the capitellum, with associated intra-articular loose bodie(s), diagnosed on plain film. Osteochondrosis dissecans (OCD) is a rather common entity. Mostly the knee joint is involved. Only 5% of OCD lesions occur in the elbow joint. Possible causes of osteochondrosis dissecans include (repetitive) trauma (e.g. in throwing sports or gymnastics), ischemia, ossification defects, and genetic factors. Conventional radiography mostly has a low sensitivity to detect OCD lesions, and is often normal in early stages. CT is more sensitive to detect intra-articular loose bodies. MRI detects very early stages of OCD and radiographically occult lesions that may not be evident on CT.

  8. Elbow arthroscopy: valgus extension overload.

    Science.gov (United States)

    Ahmad, Christopher S; Conway, John E

    2011-01-01

    Valgus torque combined with deceleration produces high compression and shear forces acting on the posteromedial olecranon and the posteromedial trochlea. This valgus extension overload process may cause posteromedial trochlea chondromalacia, chondral flap formation, osteochondrosis, subchondral erosion, a subchondral insufficiency fracture, and marginal exostosis formation. Olecranon pathologies include proximal stress reaction, a posteromedial tip stress fracture, a transverse proximal process stress fracture, exostosis formation, exostosis fragmentation, and intra-articular loose bodies. Symptoms include posteromedial elbow pain during the deceleration phase of the throwing motion. The extension impingement test reproduces posterior or posteromedial pain similar to that experienced while throwing. Special radiographic techniques and CT scans can show loose bodies and osteophyte fragmentation. Surgical treatment is indicated when symptoms persist despite nonsurgical management. Based on clinical and basic science research, all patients with valgus extension overload should be comprehensively evaluated for medial ulnar collateral ligament insufficiency. Surgical treatment is limited to the resection of osteophytes only; normal olecranon should not be resected.

  9. International piping integrity research group (IPIRG) program final report

    International Nuclear Information System (INIS)

    Schmidt, R.; Wilkowski, G.; Scott, P.; Olsen, R.; Marschall, C.; Vieth, P.; Paul, D.

    1992-04-01

    This is the final report of the International Piping Integrity Research Group (IPIRG) Programme. The IPIRG Programme was an international group programme managed by the U.S. Nuclear Regulatory Commission and funded by a consortium of organizations from nine nations: Canada, France, Italy, Japan, Sweden, Switzerland, Taiwan, the United Kingdom, and the United states. The objective of the programme was to develop data needed to verify engineering methods for assessing the integrity of nuclear power plant piping that contains circumferential defects. The primary focus was an experimental task that investigated the behaviour of circumferentially flawed piping and piping systems to high-rate loading typical of seismic events. To accomplish these objectives a unique pipe loop test facility was designed and constructed. The pipe system was an expansion loop with over 30 m of 406-mm diameter pipe and five long radius elbows. Five experiments on flawed piping were conducted to failure in this facility with dynamic excitation. The report: provides background information on leak-before-break and flaw evaluation procedures in piping; summarizes the technical results of the programme; gives a relatively detailed assessment of the results from the various pipe fracture experiments and complementary analyses; and, summarizes the advances in the state-of-the-art of pipe fracture technology resulting from the IPIRG Program

  10. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.

    1983-01-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. This results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite elements method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account an elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type elements. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation. (orig.)

  11. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.; Vaghi, H.; Ricard, A.

    1983-08-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. The results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite element method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account on elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type element. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation

  12. IPM Pipe

    Science.gov (United States)

    Submit A Report View Reports List [+] View Reports Map [+] CDM Alert System Sign Up For Alerts User Login Annual Epidemic Histories Annual Season Summaries Contact Us ipmPIPE User Login Web Administrator Login

  13. Bernoulli Suction Effect on Soap Bubble Blowing?

    Science.gov (United States)

    Davidson, John; Ryu, Sangjin

    2015-11-01

    As a model system for thin-film bubble with two gas-liquid interfaces, we experimentally investigated the pinch-off of soap bubble blowing. Using the lab-built bubble blower and high-speed videography, we have found that the scaling law exponent of soap bubble pinch-off is 2/3, which is similar to that of soap film bridge. Because air flowed through the decreasing neck of soap film tube, we studied possible Bernoulli suction effect on soap bubble pinch-off by evaluating the Reynolds number of airflow. Image processing was utilized to calculate approximate volume of growing soap film tube and the volume flow rate of the airflow, and the Reynolds number was estimated to be 800-3200. This result suggests that soap bubbling may involve the Bernoulli suction effect.

  14. Pipe grabber

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Mubashirov, S.G.; Prokopov, O.I.

    1981-05-15

    A pipe grabber is suggested which contains a housing, clamping elements and centering mechanism with drive installed on the lower end of the housing. In order to improve the reliable operation of the pipe grabber, the centering mechanism is made in the form of a reinforced ringed flexible shaft, while the drive is made in the form of elastic rotating discs. In this case the direction of rotation of the discs and the flexible shaft is the opposite.

  15. Numerical Predictions of Flow Characteristics in a 90 Degree Bended Upward Elbow Located at the Downstream Region of a Flow Control Valve (Butterfly Valve)

    International Nuclear Information System (INIS)

    Won, Se Youl; Park, Young Sheop; Kim, Yun Jung; Oh, Seung Jong

    2006-01-01

    Butterfly valves are widely used in industrial piping components. They are used for flow control in large diameter pipes because of their lightweight, simple structure and the rapidity of manipulation. Any flow disturbing components such as elbows, orifice plates and tees are recommended to be located in a distance of 8 diameters (L/D.8) from the downstream of butterfly valves to decrease the effect of flow disturbance. However, one would encounter cases where other piping components are installed in a close proximity due to the space restriction. In these cases, the numerical simulation will be useful to evaluate the impact of flow disturbances. In this study, we have examined one practical case encountered where the elbow is located in a close proximity to the butterfly valve. Due to the close proximity, we are concerned about pipe thinning and we use the numerical evaluation to determine the range of operating regime and options

  16. Dynamic stiffness of suction caissons - vertical vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    The dynamic response of offshore wind turbines are affected by the properties of the foundation and the subsoil. The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three-dimensional coupled Boundary Element/Finite Element model. Comparisons are made with known analytical and numerical solutions in order to evaluate the static and dynamic behaviour of the Boundary Element/Finite Element model. The vertical frequency dependent stiffness has been determined for different combinations of the skirt length, Poisson's ratio and the ratio between soil stiffness and skirt stiffness. Finally the dynamic behaviour at high frequencies is investigated. (au)

  17. Clinical anatomy of the elbow and shoulder.

    Science.gov (United States)

    Villaseñor-Ovies, Pablo; Vargas, Angélica; Chiapas-Gasca, Karla; Canoso, Juan J; Hernández-Díaz, Cristina; Saavedra, Miguel Ángel; Navarro-Zarza, José Eduardo; Kalish, Robert A

    The elbow patients herein discussed feature common soft tissue conditions such as tennis elbow, golfers' elbow and olecranon bursitis. Relevant anatomical structures for these conditions can easily be identified and demonstrated by cross examination by instructors and participants. Patients usually present rotator cuff tendinopathy, frozen shoulder, axillary neuropathy and suprascapular neuropathy. The structures involved in tendinopathy and frozen shoulder can be easily identified and demonstrated under normal conditions. The axillary and the suprascapular nerves have surface landmarks but cannot be palpated. In neuropathy however, physical findings in both neuropathies are pathognomonic and will be discussed. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  18. Failure analysis on a ruptured petrochemical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Harun, Mohd [Industrial Technology Division, Malaysian Nuclear Agency, Ministry of Science, Technology and Innovation Malaysia, Bangi, Kajang, Selangor (Malaysia); Shamsudin, Shaiful Rizam; Kamardin, A. [Univ. Malaysia Perlis, Jejawi, Arau (Malaysia). School of Materials Engineering

    2010-08-15

    The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

  19. Inelastic analysis of SNR-300 piping

    Energy Technology Data Exchange (ETDEWEB)

    Huebel, H [INTERATOM, Bergisch Gladbach (Germany); Di Luna, L J; Moy, G [Teledyne Engineering Services, Waltham, MA (United States)

    1983-05-01

    This paper investigates plasticity, creep, and elastic follow-up effects on a full size hot primary piping system of the German fast breeder reactor prototype, the SNR-300. A large model (327 elements, 419 nodes) of straight pipe, special elbow and hanger elements of the general purpose finite element program, MARC-CDC, is used to predict piping behavior for a heat-up, sodium loading-unloading-reloading cycle and other significant operating conditions. Included in this work are many time-dependent solution increments for a 5,000 hour creep period. Creep strains and relaxed stress results, after 5,000 hours, for the complete model are used with uniaxial and biaxial models and results to extrapolate conclusions for a 100,000 hour operating life. (author)

  20. Inelastic analysis of SNR-300 piping

    International Nuclear Information System (INIS)

    Huebel, H.; Di Luna, L.J.; Moy, G.

    1983-01-01

    This paper investigates plasticity, creep, and elastic follow-up effects on a full size hot primary piping system of the German fast breeder reactor prototype, the SNR-300. A large model (327 elements, 419 nodes) of straight pipe, special elbow and hanger elements of the general purpose finite element program, MARC-CDC, is used to predict piping behavior for a heat-up, sodium loading-unloading-reloading cycle and other significant operating conditions. Included in this work are many time-dependent solution increments for a 5,000 hour creep period. Creep strains and relaxed stress results, after 5,000 hours, for the complete model are used with uniaxial and biaxial models and results to extrapolate conclusions for a 100,000 hour operating life. (author)

  1. Crack opening area estimates in pressurized through-wall cracked elbows under bending

    International Nuclear Information System (INIS)

    Franco, C.; Gilles, P.; Pignol, M.

    1997-01-01

    One of the most important aspects in the leak-before-break approach is the estimation of the crack opening area corresponding to potential through-wall cracks at critical locations during plant operation. In order to provide a reasonable lower bound to the leak area under such loading conditions, numerous experimental and numerical programs have been developed in USA, U.K. and FRG and widely discussed in literature. This paper aims to extend these investigations on a class of pipe elbows characteristic of PWR main coolant piping. The paper is divided in three main parts. First, a new simplified estimation scheme for leakage area is described, based on the reference stress method. This approach mainly developed in U.K. and more recently in France provides a convenient way to account for the non-linear behavior of the material. Second, the method is carried out for circumferential through-wall cracks located in PWR elbows subjected to internal pressure. Finite element crack area results are presented and comparisons are made with our predictions. Finally, in the third part, the discussion is extended to elbows under combined pressure and in plane bending moment

  2. Crack opening area estimates in pressurized through-wall cracked elbows under bending

    Energy Technology Data Exchange (ETDEWEB)

    Franco, C.; Gilles, P.; Pignol, M.

    1997-04-01

    One of the most important aspects in the leak-before-break approach is the estimation of the crack opening area corresponding to potential through-wall cracks at critical locations during plant operation. In order to provide a reasonable lower bound to the leak area under such loading conditions, numerous experimental and numerical programs have been developed in USA, U.K. and FRG and widely discussed in literature. This paper aims to extend these investigations on a class of pipe elbows characteristic of PWR main coolant piping. The paper is divided in three main parts. First, a new simplified estimation scheme for leakage area is described, based on the reference stress method. This approach mainly developed in U.K. and more recently in France provides a convenient way to account for the non-linear behavior of the material. Second, the method is carried out for circumferential through-wall cracks located in PWR elbows subjected to internal pressure. Finite element crack area results are presented and comparisons are made with our predictions. Finally, in the third part, the discussion is extended to elbows under combined pressure and in plane bending moment.

  3. Video imaging measurement of interfacial wave velocity in air-water flow through a horizontal elbow

    Science.gov (United States)

    Al-Wazzan, Amir; Than, Cheok F.; Moghavvemi, Mahmoud; Yew, Chia W.

    2001-10-01

    Two-phase flow in pipelines containing elbows represents a common situation in the oil and gas industries. This study deals with the stratified flow regime between the gas and liquid phase through an elbow. It is of interest to study the change in wave characteristics by measuring the wave velocity and wavelength at the inlet and outlet of the elbow. The experiments were performed under concurrent air-water stratified flow in a horizontal transparent polycarbonate pipe of 0.05m diameter and superficial air and water velocities up to 8.97 and 0.0778 m/s respectively. A non-intrusive video imaging technique was applied to capture the waves. For image analysis, a frame by frame direct overlapping method was used to detect for pulsating flow and a pixel shifting method based on the detection of minimum values in the overlap function was used to determine wave velocity and wavelength. Under superficial gas velocity of less than 4.44 m/s, the results suggest a regular pulsating outflow produced by the elbow. At higher gas velocities, more random pulsation was found and the emergence of localized interfacial waves was detected. Wave velocities measured by this technique were found to produce satisfactory agreement with direct measurements.

  4. Management of tennis elbow by Agnikarma

    Directory of Open Access Journals (Sweden)

    Vyasadeva Mahanta

    2013-01-01

    Full Text Available Tennis elbow is a painful condition and causes restricted movement of forearm which requires treatment for long period. Till date only symptomatic treatments are available like use of anti-inflammatory analgesic drugs, steroids injection, physiotherapy, exercise etc. But none of these provide satisfactory result. Long term use of anti-inflammatory, analgesic drugs and steroids injection is also not free from the adverse effects. Usually, ′wait-and-see policy′ of treatment guideline is recommended in most of medical texts. According to Ayurveda, snayugata vata can be correlated with the condition of tennis elbow. Sushruta has advised Agnikarma for disorders of snayu (ligaments and tendons, asthi (bone, siddhi (joints etc. Hence, in this study a case of tennis elbow (snayugata vata was treated by Agnikarma, along with administration of powder of Ashwagandha and Navajivana Rasa orally, for a period of 03 weeks. This combination therapy provided considerable relief in pain and movement of the elbow joint.

  5. Management of tennis elbow by Agnikarma.

    Science.gov (United States)

    Mahanta, Vyasadeva; Dudhamal, Tukaram S; Gupta, Sanjay Kumar

    2013-01-01

    Tennis elbow is a painful condition and causes restricted movement of forearm which requires treatment for long period. Till date only symptomatic treatments are available like use of anti-inflammatory analgesic drugs, steroids injection, physiotherapy, exercise etc. But none of these provide satisfactory result. Long term use of anti-inflammatory, analgesic drugs and steroids injection is also not free from the adverse effects. Usually, 'wait-and-see policy' of treatment guideline is recommended in most of medical texts. According to Ayurveda, snayugata vata can be correlated with the condition of tennis elbow. Sushruta has advised Agnikarma for disorders of snayu (ligaments and tendons), asthi (bone), siddhi (joints) etc. Hence, in this study a case of tennis elbow (snayugata vata) was treated by Agnikarma, along with administration of powder of Ashwagandha and Navajivana Rasa orally, for a period of 03 weeks. This combination therapy provided considerable relief in pain and movement of the elbow joint.

  6. Study on structural integrity of thinned wall piping against seismic loading-overview and future program

    International Nuclear Information System (INIS)

    Nakamura, Izumi; Otani, Akihito; Shiratori, Masaki

    2005-01-01

    In order to clarify the behavior of thinned wall pipes under seismic events, cyclic in-plane and/or out-of-plane bending tests on thinned straight pipe and elbow and also shaking table tests using degraded piping system models were conducted. Relation between the failure mode and thinned condition and the influence of the final failure mode of degraded piping systems were investigated. In addition to these experiments, elastic-plastic FEM analysis using ABAQUS were conducted on thinned piping elements. It has been found that the strain concentrated point could be predicted and the cause of its generation could be explained by the simulated deformation behavior of the pipe. In order to predict the piping system's maximum response under elastic-plastic response, a simple response prediction method was proposed. Further tests and safety margin analyses of thinned pipes against seismic loading will be performed. (T. Tanaka)

  7. Irreducible lateral dislocation of the elbow.

    Directory of Open Access Journals (Sweden)

    Chhaparwal M

    1997-01-01

    Full Text Available A rare case of an irreducible post-traumatic lateral dislocation of elbow is presented. The mechanism of injury was fall on a flexed elbow with trauma on its medial aspect resulting in pronation of the forearm. At open reduction, the brachialis muscle was in the form of a tight band which prevented reduction. The ulnar nerve was entrapped in the joint.

  8. Heat Pipes

    Science.gov (United States)

    1990-01-01

    Bobs Candies, Inc. produces some 24 million pounds of candy a year, much of it 'Christmas candy.' To meet Christmas demand, it must produce year-round. Thousands of cases of candy must be stored a good part of the year in two huge warehouses. The candy is very sensitive to temperature. The warehouses must be maintained at temperatures of 78-80 degrees Fahrenheit with relative humidities of 38- 42 percent. Such precise climate control of enormous buildings can be very expensive. In 1985, energy costs for the single warehouse ran to more than 57,000 for the year. NASA and the Florida Solar Energy Center (FSEC) were adapting heat pipe technology to control humidity in building environments. The heat pipes handle the jobs of precooling and reheating without using energy. The company contacted a FSEC systems engineer and from that contact eventually emerged a cooperative test project to install a heat pipe system at Bobs' warehouses, operate it for a period of time to determine accurately the cost benefits, and gather data applicable to development of future heat pipe systems. Installation was completed in mid-1987 and data collection is still in progress. In 1989, total energy cost for two warehouses, with the heat pipes complementing the air conditioning system was 28,706, and that figures out to a cost reduction.

  9. Experimental studies of PWR primary piping under loca

    International Nuclear Information System (INIS)

    Caumette, Pierre; Garcia, J.L.

    1980-07-01

    The experimental program performed on AQUITAINE II facility is directed to study the mechanical behavior of primary PWR pipes and the forces exerted on the neighbouring structures as a consequence of a breach opening. It has been developed in the form of a quadripartite agreement between the Commissariat a l'Energie Atomique, Framatome, Electricite de France and Westinghouse. Some forty tests have been carried out with different pipe configurations (straight tube, elbow, S- or U-shaped tube) and different break types (single or double guillotine). The following aspects are investigated: - the dynamic behavior of the pipe and in particular the formation of a plastic hinge at the restraint; - the impact function of a pipe or an energy-absorbing bumper; - the lateral stability of both ends of a pipe, after a double-guillotine break [fr

  10. Nonlinear dynamic analysis of high energy line pipe whip

    International Nuclear Information System (INIS)

    Hsu, L.C.; Kuo, A.Y.; Tang, H.T.

    1983-01-01

    To facilitate potential cost savings in pipe whip protection design, TVA conducted a 1'' high pressure line break test to investigate the pipe whip behavior. The test results are available to EPRI as a data base for a generic study on nonlinear dynamic behavior of piping systems and pipe whip phenomena. This paper describes a nonlinear dynamic analysis of the TVA high energy line tests using ABAQUS-EPGEN code. The analysis considers the effects of large deformation and high strain rate on resisting moment and energy absorption capability of the analyzed piping system. The numerical results of impact forces, impact velocities, and reaction forces at pipe supports are compared to the TVA test data. The pipe whip impact time and forces have also been calculated per the current NRC guidelines and compared. The calculated pipe support reaction forces prior to impact have been found to be in good agreement with the TVA test data except for some peak values at the very beginning of the pipe break. These peaks are believed to be due to stress wave propagation which cannot be addressed by the ABAQUS code. Both the effects of elbow crushing and strain rate have been approximately simulated. The results are found to be important on pipe whip impact evaluation. (orig.)

  11. Advances on development of suction and temperature controlled oedometer cell

    International Nuclear Information System (INIS)

    Ye Weimin; Zhang Yawei; Chen Bao; Wang Min

    2010-01-01

    Oedometer cells for unsaturated soils can be classified into two types, that is, conventional unsaturated oedometer cells (high-suction unsaturated oedometer cell, high-suction and high-pressure unsaturated oedometer cell) and temperature controlled unsaturated oedometer cells. Among them, the osmotic, vapor equilibrium and axis translation techniques are often employed for suction control. The thermostat bath method and thermostatically controlled heater method are commonly used for temperature control. The lever loading system, hydraulic loading system and air pressure loading system are commonly means used for vertical pressure. Combination of osmotic (or axis translation) technique with vapor equilibrium method employed for the full range suction control, thermostatically liquid temperature control method, and the hydraulic loading system, could be used for suction, temperature and loading control in the design for unsaturated oedometer cells in the future, which can be used for study of buffer/backfill materials under high-temperature, high pressure and full range suction conditions. (authors)

  12. Remote controlled in-pipe manipulators for dye-penetrant inspection and grinding of weld roots inside of pipes

    International Nuclear Information System (INIS)

    Seeberger, E.K.

    2000-01-01

    Technical plants which have to satisfy stringent safety criteria must be continuously kept in line with the state of art. This applies in particular to nuclear power plants. The quality of piping in nuclear power plants has been improved quite considerably in recent years. By virtue of the very high quality requirements fulfilled in the manufacture of medium-carrying and pressure-retaining piping, one of the focal aspects of in-service inspections is the medium wetted inside of the piping. A remote controlled pipe crawler has been developed to allow to perform dye penetrant testing of weld roots inside piping (ID ≥ 150 mm). The light crawler has been designed such that it can be inserted into the piping via valves (gate valves, check valves,...) with their internals removed. Once in the piping, all crawler movements are remotely controlled (horizontal and vertical pipes incl. the elbows). If indications are found these discontinuities are ground according to a qualified procedure using a special grinding head attached to the crawler with complete extraction of all grinding residues. The in-pipe grinding is a special qualified three (3) step performance that ensures no residual tensile stress (less than 50 N/mm 2 ) in the finish machined austenitic material surface. The in-pipe inspection system, qualified according to both the specifications of the German Nuclear Safety Standards Commission (KTA) and the American Society of Mechanical Engineers (ASME), has already been used successfully in nuclear power plants on many occasions. (author)

  13. Investigation of suction anchor pullout capacity under undrained conditions

    OpenAIRE

    Jarand, Pollestad

    2015-01-01

    Master's thesis in Offshore technology Floating units are dependent on reliable mooring systems to ensure safety during marine operations. Suction anchors have proved to be a technologically viable and cost-effective concept. They are capable of precision installation, re-use, and provide large resistive capacity. This thesis investigates load capacity and failure modes of suction anchors subjected to vertical, horizontal (lateral), and incline loading. Suction anchor design co...

  14. Applicability of the mα-tangent Method to Estimate Plastic Limit Loads of Elbows and Branch Junctions

    Energy Technology Data Exchange (ETDEWEB)

    Gim, Jae-Min; Kim, Sang-Hyun; Bae, Kyung-Dong; Kim, Yun-Jae [Korea Univ., Seoul (Korea, Republic of); Kim, Jong-Sung [Sejong Univ., Seoul (Korea, Republic of)

    2017-06-15

    In this study, the limit loads calculated by the mα-tangent method based on the linear finite element analysis are compared with the closed form solutions that are proposed by various authors. The objects of the analysis is to select the elbow and the branch pipe which are representative structure of piping system. The applicability of the mα-tangent method are investigated by applying it to cases with various geometries. The internal pressure and the in-plane bending moment are considered and the mα-tangent method is in good agreement with the existing solutions in case of elbows. However, the limit loads calculated by the mα-tangent method for branch junctions do not agree well with the existing solutions and do not show any tendency. The reason is a biased result due to the stress concentration of the discontinuous parts.

  15. Evaluation of hypopharyngeal suction to eliminate aspiration: the Retro-Esophageal Suction (REScue) catheter.

    Science.gov (United States)

    Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M

    2015-02-01

    Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p  0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p 12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.

  16. Design criteria for piping and nozzles program

    International Nuclear Information System (INIS)

    Moore, S.E.; Bryson, J.W.

    1977-01-01

    This report reviews the activities and accomplishments of the Design Criteria for Piping and Nozzles program being conducted by the Oak Ridge National Laboratory for the period July 1, 1975, to September 30, 1976. The objectives of the program are to conduct integrated experimental and analytical stress analysis studies of piping system components and isolated and closely-spaced pressure vessel nozzles in order to confirm and/or improve the adequacy of structural design criteria and analytical methods used to assure the safe design of nuclear power plants. Activities this year included the development of a finite-element program for analyzing two closely spaced nozzles in a cylindrical pressure vessel; a limited-parameter study of vessels with isolated nozzles, finite-element studies of piping elbows, a fatigue test of an out-of-round elbow, summary and evaluation of experimental studies on the elastic-response and fatigue failure of tees, parameter studies on the behavior of flanged joints, publication of fifteen topical reports and papers on various experimental and analytical studies; and the development and acceptance of a number of design rules changes to the ASME Code. 2 figures, 2 tables

  17. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  18. Suction power output and the inertial cost of rotating the neurocranium to generate suction in fish.

    Science.gov (United States)

    Van Wassenbergh, Sam; Day, Steven W; Hernández, L Patricia; Higham, Timothy E; Skorczewski, Tyler

    2015-05-07

    To expand the buccal cavity, many suction-feeding fishes rely on a considerable contribution from dorsal rotation of the dorsal part of the head including the brains, eyes, and several bones forming the braincase and skull roof (jointly referred to as the neurocranium). As the neurocranium takes up a large part of the total mass of the head, this rotation may incur a considerable inertial cost. If so, this would suggest a significant selective pressure on the kinematics and mass distribution of the neurocranium of suction feeders. Here, an inverse dynamic model is formulated to calculate the instantaneous power required to rotate the neurocranium, approximated by a quarter ellipsoid volume of homogeneous density, as well as to calculate the instantaneous suction power based on intra-oral pressure and head volume quantifications. We applied this model to largemouth bass (Micropterus salmoides) and found that the power required to rotate the neurocranium accounts for only about 4% of the power required to suck water into the mouth. Furthermore, recovery of kinetic energy from the rotating neurocranium converted into suction work may be possible during the phase of neurocranial deceleration. Thus, we suggest that only a negligible proportion of the power output of the feeding muscles is lost as inertial costs in the largemouth bass. Consequently, the feeding performance of piscivorous suction feeders with generalised morphology, comparable to our model species, is not limited by neurocranial motion during head expansion. This suggests that it is thus not likely to be a factor of importance in the evolution of cranial shape and size. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  20. Nerve injuries do occur in elbow arthroscopy.

    Science.gov (United States)

    Hilgersom, Nick F J; van Deurzen, Derek F P; Gerritsma, Carina L E; van der Heide, Huub J L; Malessy, Martijn J A; Eygendaal, Denise; van den Bekerom, Michel P J

    2018-01-01

    The purpose is to create more awareness as well as emphasize the risk of permanent nerve injury as a complication of elbow arthroscopy. Patients who underwent elbow arthroscopy complicated by permanent nerve injury were retrospectively collected. Patients were collected using two strategies: (1) by word-of-mouth throughout the Dutch Society of Shoulder and Elbow Surgery, and the Leiden University Nerve Centre, and (2) approaching two medical liability insurance companies. Medical records were reviewed to determine patient characteristics, disease history and postoperative course. Surgical records were reviewed to determine surgical details. A total of eight patients were collected, four men and four women, ageing 21-54 years. In five out of eight patients (62.5%), the ulnar nerve was affected; in the remaining three patients (37.5%), the radial nerve was involved. Possible causes for nerve injury varied among patients, such as portal placement and the use of motorized instruments. A case series on permanent nerve injury as a complication of elbow arthroscopy is presented. Reporting on this sequel in the literature is little, however, its risk is not to be underestimated. This study emphasizes that permanent nerve injury is a complication of elbow arthroscopy, concurrently increasing awareness and thereby possibly aiding to prevention. IV, case series.

  1. International Piping Integrity Research Group (IPIRG) Program. Final report

    International Nuclear Information System (INIS)

    Wilkowski, G.; Schmidt, R.; Scott, P.

    1997-06-01

    This is the final report of the International Piping Integrity Research Group (IPIRG) Program. The IPIRG Program was an international group program managed by the U.S. Nuclear Regulatory Commission and funded by a consortium of organizations from nine nations: Canada, France, Italy, Japan, Sweden, Switzerland, Taiwan, the United Kingdom, and the United States. The program objective was to develop data needed to verify engineering methods for assessing the integrity of circumferentially-cracked nuclear power plant piping. The primary focus was an experimental task that investigated the behavior of circumferentially flawed piping systems subjected to high-rate loadings typical of seismic events. To accomplish these objectives a pipe system fabricated as an expansion loop with over 30 meters of 16-inch diameter pipe and five long radius elbows was constructed. Five dynamic, cyclic, flawed piping experiments were conducted using this facility. This report: (1) provides background information on leak-before-break and flaw evaluation procedures for piping, (2) summarizes technical results of the program, (3) gives a relatively detailed assessment of the results from the pipe fracture experiments and complementary analyses, and (4) summarizes advances in the state-of-the-art of pipe fracture technology resulting from the IPIRG program

  2. International Piping Integrity Research Group (IPIRG) Program. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Wilkowski, G.; Schmidt, R.; Scott, P. [and others

    1997-06-01

    This is the final report of the International Piping Integrity Research Group (IPIRG) Program. The IPIRG Program was an international group program managed by the U.S. Nuclear Regulatory Commission and funded by a consortium of organizations from nine nations: Canada, France, Italy, Japan, Sweden, Switzerland, Taiwan, the United Kingdom, and the United States. The program objective was to develop data needed to verify engineering methods for assessing the integrity of circumferentially-cracked nuclear power plant piping. The primary focus was an experimental task that investigated the behavior of circumferentially flawed piping systems subjected to high-rate loadings typical of seismic events. To accomplish these objectives a pipe system fabricated as an expansion loop with over 30 meters of 16-inch diameter pipe and five long radius elbows was constructed. Five dynamic, cyclic, flawed piping experiments were conducted using this facility. This report: (1) provides background information on leak-before-break and flaw evaluation procedures for piping, (2) summarizes technical results of the program, (3) gives a relatively detailed assessment of the results from the pipe fracture experiments and complementary analyses, and (4) summarizes advances in the state-of-the-art of pipe fracture technology resulting from the IPIRG program.

  3. Suction v. conventional curettage in incomplete abortion A ...

    African Journals Online (AJOL)

    This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients undergoing suction curettage had a significantly lower intra-operative blood loss (P < 0,0001) and a significantly higher mean ...

  4. MR tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Zwaan, M.; Rinast, E.; Weiss, H.D.; Pressler, M.; Vogel, H.

    1989-03-01

    MR examinations of the elbow joint of three healthy subjects and a comparison with corresponding sections of anatomical preparations show that MR tomography enables not only an excellent differentiation of muscles, tendons and of the articular capsule, but will also visualise vessels and nerve tracts. MR tomography proved superior to the conventional methods in demonstration of separate fragments and inflammatory changes in the bone on examining 11 pathological elbow joints: congenital malformation, osteochondritis dissecans, ostitis, ulnar and radial nerve lesions, completely healed radius fracture and epicondylitis of the radial and ulnar humerus. Epicondylitis could not be demonstrated by MR. Magnetic resonance tomography seems to be the only method that enables direct visualisation of the nerve paths at the elbow joint.

  5. S Tank Farm SL-119 saltwell piping failure analysis report

    International Nuclear Information System (INIS)

    Carlos, W.C.

    1994-01-01

    On January 24, 1992, while pressure testing saltwell line SL-119 in the 241-S Tank Farm, water was observed spraying out of heat trace enclosure. The SL-115, SL-116, SN-215, and SN-216 saltwell lines also recently failed pressure testing because of leaks. This study documents the pertinent facts about the SL-119 line and discusses the cause of the failures. The inspection of the SL-119 failure revealed two through-the-wall holes in the top center of the pipeline. The inspection also strongly suggests that the heat tracing system is directly responsible for causing the SL-119 failure. Poor design of the heat tracing system allowed water to enter, condense, and collect in the electric metallic tubing (EMT) carbon steel conduits. Water flowed to the bottom of the elbow of the conduit and corroded out the elbow. The design also allowed drifting desert sand to enter into the conduit and fall to the bottom (elbow) of the conduit. The sand became wet and aided in the corrosion of the elbow of the conduit. After the EMT conduits corroded though, the water dripped from the corroded ends of the EMT conduits onto the top of the saltwell pipe, corroding the two holes into the top of the line. If the heat tracing hot splice box had not allowed moisture to enter the EMT conduits, the saltwell piping would not have corroded and caused SL-119 to fail

  6. Experiments and numerical simulations of fluctuating thermal stratification in a branch pipe

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Akira; Murase, Michio; Sasaki, Toru [Inst. of Nuclear Safety System Inc., Mihama, Fukui (Japan); Takenaka, Nobuyuki; Hamatani, Daisuke [Kobe Univ. (Japan)

    2002-09-01

    Many pipes branch off from the main pipe in plants. When the main flow in the main pipe is hotter than a branch pipe that branches off downward, the hot water penetrates into the branch pipe with the cavity flow that is induced by the main flow and causes thermal stratification. If the interface of the stratification fluctuates in an occluded branch pipe, thermal fatigue may occur in pipe wall. Some experiments and numerical simulations were conducted to elucidate the mechanism of this fluctuating thermal stratification. The vortex structures were observed in the experiments of straight or bent branch pipes. When the main flow was heated and the thermal stratification interface was at the elbow, a ''burst'' phenomenon occurred in the interface in connection with large heat fluctuation. The effects of pipe shape on the length of penetration were investigated in order to modify simulation conditions. The vortex structures and the fluctuating thermal stratification at elbow in the numerical simulation showed good agreement with experiments. (author)

  7. Capitellocondylar total elbow replacement in late-stage rheumatoid arthritis

    DEFF Research Database (Denmark)

    Ovesen, Janne; Olsen, Bo Sanderhoff; Johannsen, Hans Viggo

    2012-01-01

    of instability. Other complications included 2 maltracking elbows, 2 triceps tendon ruptures, 2 cases of operative olecranon bursitis, and 2 ulnar nerve palsies. One elbow showed radiolucent lines of more than 1 mm in the circumference of the ulnar component; none of the other elbows showed any signs...

  8. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  9. Mode Identification of Guided Waves in a Curved Pipe

    International Nuclear Information System (INIS)

    Eom, Heung-Seop; Lim, Sa-Hoe; Kim, Jae-Hee

    2006-01-01

    Ultrasonic guided wave technique has been widely employed for the long range inspection of structures such as plates and pipes because it has the ability to propagate over long distances. In the nuclear power field, there recently appeared a need for on-line nondestructive monitoring which can be employed during the operation stage of power plants. As ultrasonic guided waves have shown promise for on-line monitoring of power plants, a lot of work has been done in the institutes and universities on this matter. In the case of detecting defects in simple straight pipes, the dispersion curves obtained from the modeling processes are closely akin to the experimental results. But the modeling of wave propagation in some structures, such as an elbow region of a pipe, is not practical due to elbow echo and unpredictable interface conditions. This paper presents an experimental approach to identify the most dominant modes of guided waves in a curved region of a pipe, which is a key factor in detecting flaws in a pipe

  10. Acoustic analysis of a piping system

    International Nuclear Information System (INIS)

    Misra, A.S.; Vijay, D.K.

    1996-01-01

    Acoustic pulsations in the Darlington Nuclear Generating Station, a 881 MW CANDU, primary heat transport piping system caused fuel bundle failures under short term operations. The problem was successfully analyzed using the steady-state acoustic analysis capability of the ABAQUS program. This paper describes in general, modelling of low amplitude acoustic pulsations in a liquid filled piping system using ABAQUS. The paper gives techniques for estimating the acoustic medium properties--bulk modulus, fluid density and acoustic damping--and modelling fluid-structure interactions at orifices and elbows. The formulations and techniques developed are benchmarked against the experiments given in 3 cited references. The benchmark analysis shows that the ABAQUS results are in excellent agreement with the experiments

  11. Phase 2 of the International Piping Integrity Research Group programme

    International Nuclear Information System (INIS)

    Darlaston, B.J.

    1994-01-01

    The results of phase 1 of the International Piping Integrity Research Group (IPIRG-1) programme have been widely reported. The significance of the results is reviewed briefly, in order to put the phase 2 programme into perspective. The success of phase 1 led the participants to consider further development and validation of pipe and pipe component fracture analysis technology as part of another international group programme (IPIRG-2). The benefits of combined funding and of the technical exchanges and interactions are considered to be of significant advantage and value. The phase 2 programme has been designed with the overall objective of developing and experimentally validating methods of predicting the fracture behaviour of nuclear reactor safety-related piping, to both normal operating and accident loads. The programme will add to the engineering estimation analysis methods that have been developed for straight pipes. The pipe system tests will expand the database to include seismic loadings and flaws in fittings, such as bends, elbows and tees, as well as ''short'' cracks. The results will be used to validate further the analytical methods, expand the capability to make fittings and extend the quasi-static results for the USNRC's new programme on short cracks in piping and piping welds. The IPIRG-2 programme is described to provide a clear understanding of the content, strategy, potential benefits and likely significance of the work. ((orig.))

  12. ELBOW AND WRIST INJURIES IN SPORTS

    Science.gov (United States)

    Marmor, Leonard; Bechtol, Charles O.

    1960-01-01

    Any disabling injury of the elbow or wrist should be studied roentgenographically for evidence of fracture which may not be otherwise evident but which may cause permanent disability unless the joint is immobilized for healing. “Tennis elbow” may be treated with physical therapy and analgesic injection but may require splinting or tendon stripping. Elbow sprain can occur in the growing epiphysis but is rare in adults. A jarring fall on the hand may cause fracture or dislocation at the elbow. Full extension of the joint should be restored gradually by active exercise rather than passive or forcible stretching. Fracture at the head of the radius may cause joint hemorrhage with severe pain which can be relieved by aspiration. A displacing fracture at the head of the radius requires removal of the head to prevent arthritic changes. Myositis ossificans contraindicates operation until after it has cleared. Healing of wrist fractures may be facilitated by exercise of the shoulder and elbow while the wrist is still in a cast. Fractures of the navicular bone are difficult to detect even roentgenographically and splinting may have to be done on clinical evidence alone. PMID:14421374

  13. Predisposing Effect of Elbow Alignment on the Elbow Fracture Type in Children.

    Science.gov (United States)

    Kang, Seungcheol; Park, Soo-Sung

    2015-08-01

    Under the hypothesis that the elbow alignment, namely the carrying angle, could predispose individuals to a specific type of pediatric elbow fracture after a fall onto an outstretched arm, we investigated the relationship between radiographic carrying angle and elbow fracture type in children. Retrospective case-control study. Level I pediatric trauma center. We reviewed 374 children who were diagnosed with supracondylar fracture (SCF, n = 208), lateral condylar fracture (LCF, n = 132), and radial neck fracture (RNF, n = 34). The association between the radiographic carrying angle and the fracture type was investigated. To adjust for bias, 2 statistical methods were used: multivariate analysis using a baseline-category logistic model and a case-matching method using propensity score analysis. In the multivariate analysis, with SCF patients set as the baseline category, a more valgus-deviated elbow (increased carrying angle, P = 0.011) predisposed individuals to RNF, whereas a more varus-deviated elbow (decreased carrying angle, P predisposed them to LCF. In the case-matched analysis, there were also significant differences in carrying angles between RNF and case-matched SCF patients (14.3 vs. 11.4 degrees, P = 0.013) and between LCF and case-matched SCF patients (7.7 vs. 11.7 degrees, P fall onto an outstretched elbow, could be a predisposing factor for specific types of pediatric elbow fracture. The results provide the additional information about the injury mechanisms of pediatric elbow fracture and may deepen our understanding of the fractures. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1982-01-01

    A comprehensive, up-to-date coverage of the theory, design and manufacture of heat pipes and their applications. This latest edition has been thoroughly revised, up-dated and expanded to give an in-depth coverage of the new developments in the field. Significant new material has been added to all the chapters and the applications section has been totally rewritten to ensure that topical and important applications are appropriately emphasised. The bibliography has been considerably enlarged to incorporate much valuable new information. Thus readers of the previous edition, which has established

  15. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    Science.gov (United States)

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  16. Evaluation of the plastic characteristics of piping products in relation to ASME code criteria

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1978-07-01

    Theories and test data relevant to the plastic characteristics of piping products are presented and compared with Code Equations in NB-3652 for Class 1 piping; in NC/ND-3652.2 for Class 2 and Class 3 piping. Comparisons are made for (a) straight pipe, (b) elbows, (c) branch connections, and (d) tees. The status of data (or lack of data) for other piping components is discussed. Comparisons are made between available data and the Code equations for two typical piping materials, SA106 Grade B and SA312 TP304, for Code Design Limits, and Service Limits A, B, C, and D. Conditions under which the Code Limits cannot be shown to be conservative from available data are pointed out. Based on the results of the study, recommendations for Code revisions are presented, along with recommendations for additional work

  17. A numerical analysis on thermal stratification phenomenon in the SCS piping

    International Nuclear Information System (INIS)

    Kim, Kwang Chu; Park, Man Heung; Youm, Hag Ki; Lee, Sun Ki; Kim, Tae Ryong

    2003-01-01

    A numerical study is performed to estimate on an unsteady thermal stratification phenomenon in the Shutdown Cooling System(SCS) piping branched off the Reactor Coolant System(RCS) piping of Nuclear Power Plant. In the results, turbulent penetration reaches to the 1 st isolation valve. At 500sec, the maximum temperature difference between top and bottom inner wall in piping is observed at the starting point of horizontal piping passing elbow. The temperature of coolant in the rear side of the 1 st isolation valve disk is very slowly increased and the inflection point in temperature difference curve for time is observed at 2700sec. At the beginning of turbulent penetration from RCS piping, the fast inflow generates the higher temperature for the inner wall than the outer wall in the SCS piping. In the case the hot-leg injection piping and the drain piping are connected to the SCS piping, the effect of thermal stratification in the SCS piping is decreased due to an increase of heat loss compared with no connection case. The hot-leg injection piping affected by turbulent penetration from the SCS piping has a severe temperature difference that exceeds criterion temperature stated in reference. But the drain piping located in the rear compared with the hot-leg injection piping shows a tiny temperature difference. In a viewpoint of designer, for the purpose of decreasing the thermal stratification effect, it is necessary to increase the length of vertical piping in the SCS piping, and to move the position of the hot-leg injection piping backward

  18. Boundary layer on a flat plate with suction

    International Nuclear Information System (INIS)

    Favre, A.; Dumas, R.; Verollet, E.

    1961-01-01

    This research done in wind tunnel concerns the turbulent boundary layer of a porous flat plate with suction. The porous wall is 1 m long and begins 1 m downstream of the leading edge. The Reynolds number based on the boundary layer thickness is of the order of 16.300. The suction rate defined as the ratio of the velocity perpendicular to the wall to the external flow velocity ranges from 0 to 2 per cent. The pressure gradient can be controlled. The mean velocity profiles have been determined for various positions and suction rates by means of total pressure probes together with the intensities of the turbulent velocity fluctuations components, energy spectra and correlations by means of hot wire anemometers, spectral analyser and correlator. The stream lines, the values of the viscous and turbulent shear stresses, of the local wall friction, of the turbulent energy production term, with some information on the dissipation of the energy have been derived from these measurements. For these data the integral of equation of continuity in boundary layer have been drawn. The suction effects on the boundary layer are important. The suction thoroughly alters the mean velocity profiles by increasing the viscous shear stresses near the wall and decreasing them far from the wall, it diminishes the longitudinal and transversal turbulence intensities, the turbulent shear stresses, and the production of energy of turbulence. These effects are much stressed in the inner part of the boundary layer. On the other hand the energy spectra show that the turbulence scale is little modified, the boundary layer thickness being not much diminished by the suction. The suction effects can be appreciated by comparing twice the suction rate to the wall friction coefficient (assumed airtight), quite noticeable as soon as the rate is about unity, they become very important when it reaches ten. (author) [fr

  19. Analisis Perubahan Nilai Suction Akibat Hujan Terhadap Kestabilan Lereng

    OpenAIRE

    Martini, Martini

    2009-01-01

    Infiltration of rainfall into slope will have an effect on to condition of slope hydrology and more specifically to characteristic of slope soils, for example pore water pressure value, level of saturation, weight contents of soil, shear strength of soil. Pore water pressure value at dry soil condition or wet condition called as with pore water pressure value negatife or value suction. This suction value will tend to declines and in the end becomes equal to zero or bigger than 0 ( positive po...

  20. Experimental evaluation of J in cracked straight and curved pipes under bending

    International Nuclear Information System (INIS)

    Moulin, D.; Touboul, F.; Foucher, N.; Lebey, J.; Acker, D.

    1989-01-01

    An experimental program is being carried out at the CEA Saclay in collaboration with FRAMATOME and IPSN with a view to validate analysis methods applicable for evaluation of leak before break behavior in P.W.R. piping. A large experimental work was already performed in USA, Germany and Japan and cracked pipes made of stainless steel material under bending. The methods of analysis got same validations for straight pipes. However applicability to elbows and comparison with toughness values obtained on small specimens like CT specimens was not completely dealt with

  1. Stress-deformation analysis of elbow articulation

    Czech Academy of Sciences Publication Activity Database

    Hlavoň, Pavel; Florian, Z.

    2005-01-01

    Roč. 12, č. 5 (2005), s. 331-337 ISSN 1802-1484. [Mechatronics, Robotics and Biomechanics 2005. Třešť, 26.09.2005-29.09.2005] R&D Projects: GA ČR(CZ) GA101/05/0136 Institutional research plan: CEZ:AV0Z20760514 Keywords : elbow joint * radial head replacement * radio-humeral alloplasty Subject RIV: BO - Biophysics

  2. Major Peripheral Nerve Injuries After Elbow Arthroscopy.

    Science.gov (United States)

    Desai, Mihir J; Mithani, Suhail K; Lodha, Sameer J; Richard, Marc J; Leversedge, Fraser J; Ruch, David S

    2016-06-01

    To survey the American Society for Surgery of the Hand membership to determine the nature and distribution of nerve injuries treated after elbow arthroscopy. An online survey was sent to all members of the American Society for Surgery of the Hand under an institutional review board-approved protocol. Collected data included the number of nerve injuries observed over a 5-year period, the nature of treatment required for the injuries, and the outcomes observed after any intervention. Responses were anonymous, and results were securely compiled. We obtained 372 responses. A total of 222 nerve injuries were reported. The most injured nerves reported were ulnar, radial, and posterior interosseous (38%, 22%, and 19%, respectively). Nearly half of all patients with injuries required operative intervention, including nerve graft, tendon transfer, nerve repair, or nerve transfer. Of the patients who sustained major injuries, those requiring intervention, 77% had partial or no motor recovery. All minor injuries resolved completely. Our results suggest that major nerve injuries after elbow arthroscopy are not rare occurrences and the risk of these injuries is likely under-reported in the literature. Furthermore, patients should be counseled on this risk because most nerve injuries show only partial or no functional recovery. With the more widespread practice of elbow arthroscopy, understanding the nature and sequelae of significant complications is critically important in ensuring patient safety and improving outcomes. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Fundamentals of piping design

    CERN Document Server

    Smith, Peter

    2013-01-01

    Written for the piping engineer and designer in the field, this two-part series helps to fill a void in piping literature,since the Rip Weaver books of the '90s were taken out of print at the advent of the Computer Aid Design(CAD) era. Technology may have changed, however the fundamentals of piping rules still apply in the digitalrepresentation of process piping systems. The Fundamentals of Piping Design is an introduction to the designof piping systems, various processes and the layout of pipe work connecting the major items of equipment forthe new hire, the engineering student and the vetera

  4. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. 5 refs

  5. The Wick-Concept for Thermal Insulation of Cold Piping

    DEFF Research Database (Denmark)

    Koverdynsky, Vit; Korsgaard, Vagn; Rode, Carsten

    2006-01-01

    the wick-concept in either of two variations: the self-drying or the self-sealing system. Experiments have been carried out using different variations of the two systems to investigate the conditions for exploiting the drying capabilities of the systems, and the results are presented. The results show......The wick-concept for thermal insulation of cold piping is based on capillary suction of a fiber fabric to remove excess water from the pipe surface by transporting it to the outer surface of the insulation. From the surface of the insulation jacket, the water will evaporate to the ambient air....... This will prevent long-term accumulation of moisture in the insulation material. The wick keeps the hydrophobic insulation dry, allowing it to maintain its thermal performance. The liquid moisture is kept only in the wick fabric. This article presents the principle of operation of cold pipe insulation using...

  6. SCC-induced failure of a 304 stainless steel pipe

    International Nuclear Information System (INIS)

    Tapping, R.L.; Disney, D.J.; Szostak, F.J.

    1993-01-01

    On 1991 January 12, a 304 Stainless Steel (SS) suction line in the AECL-Research NRU reactor failed, shutting down the reactor for approximately 12 months. The pipe, a 32 mm schedule 40 304 stainless steel line exposed to D 2 O at temperatures ≤35 degrees C had been in service for approximately 20 years, although no manufacturing data or composition specifications were available. The failure and resultant leak resulted in a small loss of D 2 O moderator from the reactor vessel. The pipe cracked approximately 180 degrees C around the circumference of a weld. This failure was unexpected and hense a thorough metallographic examination was carried out on the failed section, on the rest of the line (Line 1212), and on representative samples from the rest of the reactor in order to assess the integrity of the remaining piping

  7. Identification and reduction of piping-vibrations in plants

    Energy Technology Data Exchange (ETDEWEB)

    Kerkhof, K. [Stuttgart Univ. (Germany). MPA

    2012-07-01

    Safe operation, availability and lifetime assessment of piping systems are of utmost concern for plant operators. The use of tuned mass dampers is a rather new approach for reducing vibrations to avoid high cycle fatigue in a large chemical piping system. The investigated piping system is supported by a tall structure fixed at the base. As a result, the steel building stiffness decreases with height. Furthermore large piping-elbow forces act at the top of the building, which lead to large vibration amplitudes. Since both piping system and supporting structure exhibited these large vibration amplitudes, dampers or shock absorbers placed between them would prove ineffective. Therefore, special vibration absorbers were developed for such piping systems. The paper presents the design process, starting with an extensive system investigation up to the passive multi-axial vibration absorber design parameters. This includes: Laboratory tests with a mock-up pipe system, where the first design ideas for new passive vibration absorbers were investigated. Vibration measurements were carried out to investigate the current state of the vibration behaviour. The piping system was inspected; strain gauges were used to identify stress concentrations at welds and other notches due to ovalization. Finite element calculations were performed, first as a combined beam and shell model for the pipe without the support structure. A detailed model for the combined steel construction and pipe system was created. Model-updating was done to fit the calculated model to the experimental modal analysis data. Loading assumptions describing excitation forces from the mass flow were checked. Harmonic frequency analysis was performed. On the basis of these calculations design parameters for the passive vibration absorber were determined. Finally, a solution for the design of two passive vibration absorbers will be presented.

  8. Identification and reduction of piping-vibrations in plants

    International Nuclear Information System (INIS)

    Kerkhof, K.

    2012-01-01

    Safe operation, availability and lifetime assessment of piping systems are of utmost concern for plant operators. The use of tuned mass dampers is a rather new approach for reducing vibrations to avoid high cycle fatigue in a large chemical piping system. The investigated piping system is supported by a tall structure fixed at the base. As a result, the steel building stiffness decreases with height. Furthermore large piping-elbow forces act at the top of the building, which lead to large vibration amplitudes. Since both piping system and supporting structure exhibited these large vibration amplitudes, dampers or shock absorbers placed between them would prove ineffective. Therefore, special vibration absorbers were developed for such piping systems. The paper presents the design process, starting with an extensive system investigation up to the passive multi-axial vibration absorber design parameters. This includes: Laboratory tests with a mock-up pipe system, where the first design ideas for new passive vibration absorbers were investigated. Vibration measurements were carried out to investigate the current state of the vibration behaviour. The piping system was inspected; strain gauges were used to identify stress concentrations at welds and other notches due to ovalization. Finite element calculations were performed, first as a combined beam and shell model for the pipe without the support structure. A detailed model for the combined steel construction and pipe system was created. Model-updating was done to fit the calculated model to the experimental modal analysis data. Loading assumptions describing excitation forces from the mass flow were checked. Harmonic frequency analysis was performed. On the basis of these calculations design parameters for the passive vibration absorber were determined. Finally, a solution for the design of two passive vibration absorbers will be presented.

  9. Suction generation in white-spotted bamboo sharks Chiloscyllium plagiosum.

    Science.gov (United States)

    Wilga, Cheryl D; Sanford, Christopher P

    2008-10-01

    After the divergence of chondrichthyans and teleostomes, the structure of the feeding apparatus also diverged leading to alterations in the suction mechanism. In this study we investigated the mechanism for suction generation during feeding in white-spotted bamboo sharks, Chiloscyllium plagiosum and compared it with that in teleosts. The internal movement of cranial elements and pressure in the buccal, hyoid and pharyngeal cavities that are directly responsible for suction generation was quantified using sonomicrometry and pressure transducers. Backward stepwise multiple linear regressions were used to explore the relationship between expansion and pressure, accounting for 60-96% of the variation in pressure among capture events. The progression of anterior to posterior expansion in the buccal, hyoid and pharyngeal cavities is accompanied by the sequential onset of subambient pressure in these cavities as prey is drawn into the mouth. Gape opening triggers the onset of subambient pressure in the oropharyngeal cavities. Peak gape area coincides with peak subambient buccal pressure. Increased velocity of hyoid area expansion is primarily responsible for generating peak subambient pressure in the buccal and hyoid regions. Pharyngeal expansion appears to function as a sink to receive water influx from the mouth, much like that of compensatory suction in bidirectional aquatic feeders. Interestingly, C. plagiosum generates large suction pressures while paradoxically compressing the buccal cavity laterally, delaying the time to peak pressure. This represents a fundamental difference from the mechanism used to generate suction in teleost fishes. Interestingly, pressure in the three cavities peaks in the posterior to anterior direction. The complex shape changes that the buccal cavity undergoes indicate that, as in teleosts, unsteady flow predominates during suction feeding. Several kinematic variables function together, with great variation over long gape cycles to

  10. Natural course in tennis elbow--lateral epicondylitis after all?

    Science.gov (United States)

    Zeisig, Eva

    2012-12-01

    Tennis elbow is a common and difficult-to-treat condition largely because of lack of evidence. The natural history is unknown, but the condition is described as self-limiting. The objective of this case report is to describe the natural course of two control participants (pain free), who later developed tennis elbow, patient history, clinical findings, and ultrasound and colour Doppler examination before, during and after a period of tennis elbow.

  11. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized

  12. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection.

    Science.gov (United States)

    Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C

    2015-10-01

    Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces

  13. Dielectric elastomer actuators for octopus inspired suction cups.

    Science.gov (United States)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  14. Octopus-like suction cups: from natural to artificial solutions.

    Science.gov (United States)

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  15. Dielectric elastomer actuators for octopus inspired suction cups

    International Nuclear Information System (INIS)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-01-01

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms. (paper)

  16. Nirschl surgical technique for concomitant lateral and medial elbow tendinosis: a retrospective review of 53 elbows with a mean follow-up of 11.7 years.

    Science.gov (United States)

    Schipper, Oliver N; Dunn, Jonathan H; Ochiai, Derek H; Donovan, J Skye; Nirschl, Robert P

    2011-05-01

    Combined lateral elbow tendinosis (tennis elbow) and medial elbow tendinosis (golfer's elbow) can be a disabling condition that, if unresponsive to nonoperative treatments, may be effectively treated surgically. The authors are not aware of any study that reports the outcome of a combined operation for lateral and medial elbow tendinosis (country club elbow) performed in the same operative setting. Combined surgical treatment of country club elbow in the same operative setting has similar outcomes to those seen in the literature for single operative procedures. Case series; Level of evidence 4. Outcome measurements included the Numeric Pain Intensity Scale, the Nirschl tennis elbow scoring system, and the American Shoulder and Elbow Surgeons elbow form. Forty-eight patients (53 clinical elbows) were available by telephone, with a minimum time to follow-up of 5 years (range, 5-19 years; mean, 11.7 years). The average Nirschl tennis elbow score improved from 16.7 preoperatively to 70.8 postoperatively (P Elbow Surgeons elbow score improved from 45.2 to 90.4 (P tennis elbow score, results were rated excellent in 38 elbows, good in 7 elbows, fair in 5 elbows, and poor in 3 elbows, with 85% (45 of 53) good to excellent results. Patient satisfaction with the surgery averaged 8.7 out of 10. Of the 46 patients who played sports, 44 (96%) reported returning to their sports. When nonoperative treatment of lateral and medial elbow tendinosis fails, combined surgical intervention via the Nirschl operative techniques for country club elbow is highly effective, with results similar to those of single-sided intervention.

  17. HPFRCC - Extruded Pipes

    DEFF Research Database (Denmark)

    Stang, Henrik; Pedersen, Carsten

    1996-01-01

    The present paper gives an overview of the research onHigh Performance Fiber Reinforced Cementitious Composite -- HPFRCC --pipes recently carried out at Department of Structural Engineering, Technical University of Denmark. The project combines material development, processing technique development......-w$ relationship is presented. Structural development involved definition of a new type of semi-flexiblecement based pipe, i.e. a cement based pipe characterized by the fact that the soil-pipe interaction related to pipe deformation is an importantcontribution to the in-situ load carrying capacity of the pipe...

  18. Pipe drafting and design

    CERN Document Server

    Parisher, Roy A; Parisher

    2000-01-01

    Pipe designers and drafters provide thousands of piping drawings used in the layout of industrial and other facilities. The layouts must comply with safety codes, government standards, client specifications, budget, and start-up date. Pipe Drafting and Design, Second Edition provides step-by-step instructions to walk pipe designers and drafters and students in Engineering Design Graphics and Engineering Technology through the creation of piping arrangement and isometric drawings using symbols for fittings, flanges, valves, and mechanical equipment. The book is appropriate primarily for pipe

  19. Measurement of pipe wall thinning by ultra acoustic resonance technique using optical fiber

    International Nuclear Information System (INIS)

    Shirai, Takehiro; Machijima, Yuichi

    2009-01-01

    This is the novel system for Pipe Wall Thickness measurement which is combined EAMT(Electro Magnetic Acoustic Transducer) and Optical Fiber Sensor. The conventional ultrasonic thickness meter is using in pipe wall thickness measurement. However, it is necessary to remove a heat insulator from pipe line. A characteristic of this novel system is that it is possible to measure without removing a heat insulator and on-line monitoring, because of measurement probe is attached between pipe surface and heat insulator. As a result of measured with this system, we could measure 30 mm thickness of carbon and stainless steel at the maximum and pipe specimen of elbow shape. Heat-resistant characteristic confirmed at 200 degrees C until about 7000 hours. (author)

  20. Laminar flow in porous pipes and ducts with variable suction or injection at the wall

    International Nuclear Information System (INIS)

    Souza Araujo, P.M. de; Stuckenbruck, S.

    1977-01-01

    The laminar flow of an incompressible fluid is analysed along a porous-walled straight circular tube and a flat duct formed by parallel porous plates. The non-similarity of velocity profiles is verified and the analytical solution is obtained by expanding the axial velocity component in a power series. The mass flow through the walls is taken into consideration as an application of Darcy's Law. Adverse axial pressure gradients and occasional reverse flow near the wall are pointed out in the work. (Author) [pt

  1. Tennis elbow: role of local steroid injection.

    Science.gov (United States)

    Ahmed, Gulzar Saeed; Ali, Muhammad; Trago, Imtiaz Ahmed

    2012-01-01

    Tennis elbow is a condition, characterised by pain and tenderness over the lateral epicondyle of the humerus, and pain on resisted dorsiflexion of the wrist, middle finger, or both. The aim of this randomised controlled trial was to investigate the short term efficacy of local steroid injection compared with oral and topical NSAIDs. Sixty patients (45 male and 15 female) were included in the study. The mean age was 42 years for men and 40 years for women. They were placed in group A and B (30 cases each). Group A received local steroid injection (triamcinolone 20 mg mixed with lignocaine 2% 1 cc) and topical NSAID cream application (diclofenac diethylammonium) twice a day, tab. diclofenac sodium 50 mg twice a day for 3 weeks. Group B received tab diclofenac 50 mg twice a day and, topical NSAID cream application twice a day for 3 weeks. Assessment of patients was made 3 times; first at the start of the study, 2nd time after 6 weeks, and 3rd time after 12 weeks. A blinded assessor rated the elbow complaints of the patients at resisted dorsiflexion of wrist using VAS (0 = no severity, 1-3 mild, 4-6 moderate, 7-9 sever, 10 = maximum severity). At six weeks, 22 (73.33%) patient in group A had no pain as compared to 7 (23.33%) patients in group B who were pain free (p < 0.0001, chi2 = 38.75). At 12 weeks 27 (90%) patients in group A were pain free compared to group B in which 7 (23.33%) patients were pain free (p < 0.0001, chi2 = 27.56). In patients with tennis elbow, the use of local steroid injection in combination with topical and oral NSAIDs is superior to the use of combination of topical and oral NSAIDs. Better results with combination therapy using local steroid injection may be limited to the short term.

  2. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  3. Spinal cord electrophysiology II: extracellular suction electrode fabrication.

    Science.gov (United States)

    Garudadri, Suresh; Gallarda, Benjamin; Pfaff, Samuel; Alaynick, William

    2011-02-20

    Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively.

  4. Shoulder-elbow exoskeleton as rehabilitation exerciser

    Science.gov (United States)

    Ianoşi, A.; Dimitrova, A.; Noveanu, S.; Tătar, O. M.; Mândru, D. S.

    2016-08-01

    This paper presents a 2 degree of freedom exoskeleton designed for the rehabilitation of the shoulder and elbow movement in the sagittal plane; a semi-portable design strategy was chosen, which enables an easy attachment to a standard medical chair as well as the patient upper limb. A dedicated driver enables the control from a graphical user interface, which also provides the option of customized rehabilitation exercises. The potential of future improvements is assessed, and recommendations of research direction are made in order to broaden the usability of the proposed device.

  5. Development of a J-estimation scheme for internal circumferential and axial surface cracks in elbows

    International Nuclear Information System (INIS)

    Mohan, R.; Brust, F.W.; Ghadiali, N.; Wilkowski, G.

    1996-06-01

    This report summarizes efforts to develop elastic and elastic-plastic fracture mechanics analyses for internal surface cracks in elbows. The analyses involved development of a GE/EPRI type J-estimation scheme which requires an elastic and fully plastic contribution to crack-driving force in terms of the J-integral parameter. The elastic analyses require the development of F-function values to relate the J e term to applied loads. Similarly, the fully plastic analyses require the development of h-functions to relate the J p term to the applied loads. The F- and h-functions were determined from a matrix of finite element analyses. To minimize the cost of the analyses, three-dimensional ABAQUS finite element analyses were compared to a simpler finite element technique called the line-spring method. The line-spring method provides a significant computational savings over the full three-dimensional analysis. The comparison showed excellent agreement between the line-spring and three-dimensional analysis. This experience was consistent with comparisons with circumferential surface-crack analyses in straight pipes during the NRC's Short Cracks in Piping and Piping Welds program

  6. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    Directory of Open Access Journals (Sweden)

    AZZEDINE NAHOUI

    2013-12-01

    Full Text Available A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has demonstrated its positive effect on the transition point and the friction coefficient. Both control procedures are compared for different lengths, speeds and angles of blowing and suction.

  7. Pad for holding a load against a surface by suction

    International Nuclear Information System (INIS)

    Farmer, R.C.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention concerns suction pads for supporting loads. Specifically, the suction pad is part of a pair of pads located at the ends of a bridge forming a vehicle for transporting instruments for the non-destructive testing of a large vessel intended to contain a fuel assembly for a nuclear reactor immersed in a liquid metal coolant. For example, the vehicle is of the type described in the French patent application filed this day under the heading 'Vehicle for transporting instruments for testing against a wall' [fr

  8. Device for the prehension by means of suction cups

    International Nuclear Information System (INIS)

    Gabillet, Maurice

    1980-01-01

    The difficulties encountered while utilising suction-cups, are mainly caused by the skirts. The skirts are more or less adaptable to the surface of the objects to be handled. The skirt of the device presented, is made out of a round supple elastic bag containing solid particles. By creating a vacuum in the bag, the particles become a solid entity. The bag filled with the particles becomes rigid and can take exactly the shape of the object to be lifted. By creating a second vacuum in the axis of the bag, the object can be lifted. Several suction-cups can be used simultaneously

  9. Analysis of the fitness for service of the elbow of the line 8D24 of the cooling system stop CNE and corrective actions taken

    International Nuclear Information System (INIS)

    Bourguigne, G.

    2013-01-01

    Given the thickness measurements recorded on the Shutdown Cooling System of Embalse NGS, it was noted that one of the bends had values below the pressure based minimum thickness and because of that, a fitness for service evaluation of the elbow was necessary. The system consists of a pump and a heat exchanger on both sides of the reactor connected between the inlet and outlet headers of both loops. All piping is Class1 and therefore must comply with ASME BPVC, Section III rules. This evaluation was done using the same loads and operating conditions as the ones uses on the design stage, using the original Stress Report of the system as a reference. Due to calculated stresses being near the limits, it was decided that a repair action should take place on the elbow and that applying an external cladding to the locally thinned area was the best option. Finally an evaluation of the repair done on the elbow was performed, finding that the elbow is fit for service following ASME- Section III rules and limits.Given the thickness measurements recorded on the Shutdown Cooling System of Embalse NGS, it was noted that one of the bends had values below the pressure based minimum thickness and because of that, a fitness for service evaluation of the elbow was necessary. The system consists of a pump and a heat exchanger on both sides of the reactor connected between the inlet and outlet headers of both loops. All piping is Class1 and therefore must comply with ASME BPVC, Section III rules. This evaluation was done using the same loads and operating conditions as the ones uses on the design stage, using the original Stress Report of the system as a reference. Due to calculated stresses being near the limits, it was decided that a repair action should take place on the elbow and that applying an external cladding to the locally thinned area was the best option. Finally an evaluation of the repair done on the elbow was performed, finding that the elbow is fit for service following

  10. Orthotic devices for the treatment of tennis elbow

    NARCIS (Netherlands)

    Struijs, P. A. A.; Smidt, N.; Arola, H.; Dijk, van C. N.; Buchbinder, R.; Assendelft, W. J. J.

    2002-01-01

    BACKGROUND: Lateral epicondylitis (tennis elbow) is a frequently reported condition. A wide variety of treatment strategies has been described. As of yet, no optimal strategy has been identified. OBJECTIVES: To assess the effectiveness of orthotic devices for the treatment of tennis elbow. SEARCH

  11. Orthotic devices for tennis elbow: a systematic review

    NARCIS (Netherlands)

    Struijs, P. A.; Smidt, N.; Arola, H.; van Dijk, C. N.; Buchbinder, R.; Assendelft, W. J.

    2001-01-01

    Lateral epicondylitis (tennis elbow) is af requently reported condition. A wide variety of treatment strategies has been described. Asy et, no optimal strategy has been identified. The aim of this review was to assess the effectiveness of orthotic devices for treatment of tennis elbow. An electronic

  12. Biomechanics of the elbow joint in tennis players.

    NARCIS (Netherlands)

    Eygendaal, D.; Rahussen, F.T.; Diercks, R.L.

    2007-01-01

    Elbow injuries constitute a sizeable percentage of tennis injuries. A basic understanding of biomechanics of tennis and analysis of forces, loads and motions of the elbow during tennis can will improve the understanding of the pathophysiology of these injuries. All different strokes in tennis have a

  13. MR imaging of the elbow in baseball pitchers

    Energy Technology Data Exchange (ETDEWEB)

    Ouellette, Hugue; Bredella, Miriam; Palmer, William E.; Torriani, Martin [Massachusetts General Hospital, Division of Musculoskeletal Radiology, Boston, MA (United States); Labis, John [Methodist Hospital, Houston, TX (United States)

    2008-02-15

    Baseball pitcher throwing biomechanics are important to understanding the pathophysiology and magnetic resonance (MR) imaging appearances of injuries in baseball pitchers. Baseball pitchers experience repetitive excessive valgus forces at the elbow. Typical injuries are secondary to medial joint distraction, lateral joint compression, and rotatory forces at the olecranon. MR imaging is useful for evaluation of the elbow in baseball pitchers. (orig.)

  14. ERRORS AT RESTORATIVE TREATMENT OF CHILDREN WITH ELBOW INJURIES

    Directory of Open Access Journals (Sweden)

    N. A. Ovsyankin

    2010-01-01

    Full Text Available Presented analysis based on a large clinical material of reconstructive management of children with posttraumatic contractures of the elbow joint. In reconstructive management of children a plenty of errors are committed, and most of them are through undervaluation of displacements that have not been eliminated after bone fractures at the elbow joint.

  15. The treatment of recurrent posterolateral instability of the elbow

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole

    2003-01-01

    This study describes the surgical technique used for reconstruction and reinforcement of the lateral collateral ligament complex in patients with posterolateral instability of the elbow and the results. A triceps tendon graft from the ipsilateral elbow which was inserted through bone tunnels...

  16. Assessment of induction elbows for an ASME Code application

    International Nuclear Information System (INIS)

    Panesar, J.S.; Soliman, M.

    1991-01-01

    The ASME Nuclear Codes impose some specific requirements on the wall thickness uniformity and the out-of-roundness of cross sections of the elbows for Nuclear Power Plant applications. Due to some of these requirements, manufacturing and installation of these elbows can be time consuming and quite expensive. This paper explores the feasibility of using induction elbows for nuclear application from the stress analysis point of view. To this end, three different sizes of 90deg elbows have been analyzed based on the geometry of an 'ASME Code' elbow and an elbow formed by induction bending. The analysis is carried out for internal pressure, in-plane and out-of-plane loads. Based on the results of these three carbon steel elbows, the use of induction elbows in some of the CANDU-PHW (CANadian Deuterium Uranium-Pressurized Heavy Water) power plant applications seems encouraging. However, before the feasibility can be fully confirmed analysis and induction bending tests over a wider range of geometries, loading conditions, and materials are required. (author)

  17. Tips to avoid nerve injury in elbow arthroscopy

    NARCIS (Netherlands)

    Hilgersom, Nick F. J.; Oh, Luke S.; Flipsen, Mark; Eygendaal, Denise; van den Bekerom, Michel P. J.

    2017-01-01

    Elbow arthroscopy is a technical challenging surgical procedure because of close proximity of neurovascular structures and the limited articular working space. With the rising number of elbow arthroscopies being performed nowadays due to an increasing number of surgeons performing this procedure and

  18. Kinematics of the lateral ligamentous constraints of the elbow joint

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole; Dalstra, Michel

    1996-01-01

    preventer of elbow joint laxity. The LCLC was observed to be a complex structure of ligamentous fibers rather than discreet bands. The LCLC forms a ligamentous constraint between the lateral humeral epicondyle and the ulna, stabilizing the elbow joint and forming a base for radial head stability...

  19. Validation of the Danish version of the Oxford Elbow Score

    DEFF Research Database (Denmark)

    Plaschke, Hans Christian; Jørgensen, Andreas Møller; Thillemann, Theis Muncholm

    2013-01-01

    The Oxford Elbow Score (OES) is a patient-related outcome measure quantifying quality of life in relation to elbow disorders. This 12-item patient-administered English questionnaire comprises three domains: function, social-psychological status and pain. The purpose of this study was to examine...

  20. Evaluation and Management of Elbow Tendinopathy

    Science.gov (United States)

    Taylor, Samuel A.; Hannafin, Jo A.

    2012-01-01

    Context: Elbow tendinopathy is a common cause of pain and disability among patients presenting to orthopaedic surgeons, primary care physicians, physical therapists, and athletic trainers. Prompt and accurate diagnosis of these conditions facilitates a directed treatment regimen. A thorough understanding of the natural history of these injuries and treatment outcomes will enable the appropriate management of patients and their expectations. Evidence Acquisitions: The PubMed database was searched in December 2011 for English-language articles pertaining to elbow tendinopathy. Results: Epidemiologic data as well as multiple subjective and objective outcome measures were investigated to elucidate the incidence of medial epicondylitis, lateral epicondylitis, distal biceps and triceps ruptures, and the efficacy of various treatments. Conclusions: Medial and lateral epicondylitis are overuse injuries that respond well to nonoperative management. Their etiology is degenerative and related to repetitive overuse and underlying tendinopathy. Nonsteroidal anti-inflammatory drugs and localized corticosteroid injections yield moderate symptomatic relief in short term but do not demonstrate benefit on long-term follow-up. Platelet-rich plasma injections may be advantageous in cases of chronic lateral epicondylitis. If 6 to 12 months of nonoperative treatment fails, then surgical intervention can be undertaken. Distal biceps and triceps tendon ruptures, in contrast, have an acute traumatic etiology that may be superimposed on underlying tendinopathy. Prompt diagnosis and treatment improve outcomes. While partial ruptures confirmed with magnetic resonance imaging can be treated nonoperatively with immobilization, complete ruptures should be addressed with primary repair within 3 to 4 weeks of injury. PMID:23016111

  1. Pipe-to-pipe impact program

    International Nuclear Information System (INIS)

    Alzheimer, J.M.; Bampton, M.C.C.; Friley, J.R.; Simonen, F.A.

    1984-06-01

    This report documents the tests and analyses performed as part of the Pipe-to-Pipe Impact (PTPI) Program at the Pacific Northwest Laboratory. This work was performed to assist the NRC in making licensing decisions regarding pipe-to-pipe impact events following postulated breaks in high energy fluid system piping. The report scope encompasses work conducted from the program's start through the completion of the initial hot oil tests. The test equipment, procedures, and results are described, as are analytic studies of failure potential and data correlation. Because the PTPI Program is only partially completed, the total significance of the current test results cannot yet be accurately assessed. Therefore, although trends in the data are discussed, final conclusions and recommendations will be possible only after the completion of the program, which is scheduled to end in FY 1984

  2. Solar heating pipe

    Energy Technology Data Exchange (ETDEWEB)

    Hinson-Rider, G.

    1977-10-04

    A fluid carrying pipe is described having an integral transparent portion formed into a longitudinally extending cylindrical lens that focuses solar heat rays to a focal axis within the volume of the pipe. The pipe on the side opposite the lens has a heat ray absorbent coating for absorbing heat from light rays that pass through the focal axis.

  3. Investigation of erosion behavior in different pipe-fitting using Eulerian-Lagrangian approach

    Science.gov (United States)

    Kulkarni, Harshwardhan; Khadamkar, Hrushikesh; Mathpati, Channamallikarjun

    2017-11-01

    Erosion is a wear mechanism of piping system in which wall thinning occurs because of turbulent flow along with along with impact of solid particle on the pipe wall, because of this pipe ruptures causes costly repair of plant and personal injuries. In this study two way coupled Eulerian-Lagrangian approach is used to solve the liquid solid (water-ferrous suspension) flow in the different pipe fitting namely elbow, t-junction, reducer, orifice and 50% open gate valve. Simulations carried out using incomressible transient solver in OpenFOAM for different Reynolds's number (10k, 25k, 50k) and using WenYu drag model to find out possible higher erosion region in pipe fitting. Used transient solver is a hybrid in nature which is combination of Lagrangian library and pimpleFoam. Result obtained from simulation shows that exit region of elbow specially downstream of straight, extradose of the bend section more affected by erosion. Centrifugal force on solid particle at bend affect the erosion behavior. In case of t-junction erosion occurs below the locus of the projection of branch pipe on the wall. For the case of reducer, orifice and a gate valve reduction area as well as downstream is getting more affected by erosion because of increase in velocities.

  4. Vortex breakdown in simple pipe bends

    Science.gov (United States)

    Ault, Jesse; Shin, Sangwoo; Stone, Howard

    2016-11-01

    Pipe bends and elbows are one of the most common fluid mechanics elements that exists. However, despite their ubiquity and the extensive amount of research related to these common, simple geometries, unexpected complexities still remain. We show that for a range of geometries and flow conditions, these simple flows experience unexpected fluid dynamical bifurcations resembling the bubble-type vortex breakdown phenomenon. Specifically, we show with simulations and experiments that recirculation zones develop within the bends under certain conditions. As a consequence, fluid and particles can remain trapped within these structures for unexpectedly-long time scales. We also present simple techniques to mitigate this recirculation effect which can potentially have impact across industries ranging from biomedical and chemical processing to food and health sciences.

  5. The role of arthroscopy in chronic elbow instability.

    Science.gov (United States)

    Goodwin, David; Dynin, Maria; Macdonnell, J Ryan; Kessler, Michael W

    2013-12-01

    Elbow arthroscopy has had an emerging role in the management of many disorders of the elbow. In patients with chronic elbow instability, several arthroscopic techniques have been described in the diagnosis and management of posterolateral rotatory instability and valgus instability. We performed a systematic review investigating the role of arthroscopy in posterolateral rotatory instability and valgus instability in the elbow using the PubMed and CINAHL (Cumulative Index to Nursing and Allied Health Literature) databases, and the Cochrane Database of Systematic Reviews, consisting of articles from peer-reviewed journals published in the English language after January 1, 1991. Search criteria initially identified 249 articles. Twenty-five articles met criteria for inclusion. This included 17 review articles, 4 cadaveric studies, 3 retrospective studies, and 1 prospective study. Two of the retrospective studies compared arthroscopic and open techniques. Articles included in this systematic review concluded that arthroscopy is an accurate adjunct to physical examination and imaging in the diagnosis of chronic elbow instability and affords an exceptional view of the joint with the ability to address intra-articular pathologic conditions. Arthroscopic surgical techniques have shown equivalent clinical outcomes in a comparison of arthroscopic and open techniques. Elbow arthroscopy is a valuable tool in the diagnosis and management of chronic elbow instability. Patients treated arthroscopically benefit from additional diagnostic techniques, improved visualization of the elbow joint, the ability to address coexisting intra-articular pathologic conditions, and minimal soft tissue injury with no clinical consequences in outcomes. With such significant advantages, the use of elbow arthroscopy is likely to expand in the management of chronic elbow instability. Level IV, systematic review. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc

  6. Chronic elbow dislocation: a rare complication of tennis elbow surgery. Successful treatment by open reduction and external fixator.

    Science.gov (United States)

    Degreef, I; De Smet, L

    2007-06-01

    A case is presented of chronic dislocation of the elbow after tennis elbow surgery combined with posterior interosseous nerve (PIN) release. An open reduction with repair of the collateral ligaments was performed. Postoperative rehabilitation involved the use of an articulated external fixator and there was a successful outcome. Possible causes of the dislocation are discussed.

  7. Radon Sub-slab Suctioning System Integrated in Insulating Layer

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    This poster presents a new radon sub-slab suctioning system. This system makes use of a grid of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground floor slab. For this purpose a new system of prefabricated lightweight elements is introduced...

  8. 21 CFR 878.5040 - Suction lipoplasty system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...) Classification. Class II (special controls). Consensus standards and labeling restrictions. [63 FR 7705, Feb. 17...

  9. Suction blister lesions and epithelialization monitored by optical coherence tomography

    DEFF Research Database (Denmark)

    Ahlström, M G; Gjerdrum, L M R; Larsen, H F

    2018-01-01

    suction blister was raised on each buttock, and the blister roof was excised. Lesions were covered with moisture-retaining dressing. In Study 1, the lesions were OCT-scanned on day 0 (D0), D2 and D4 and excised for histological examination. In Study 2, the progress of epithelialization and skin barrier...

  10. Improved Suction Technique for the Characterization of Construction Materials

    DEFF Research Database (Denmark)

    Thygesen, Lisbeth Garbrecht; Hansen, Kurt Kielsgaard

    2007-01-01

    The suction technique is a method from soil science that is used for the study of moisture storage capacity in porous construction materials at high relative humidity levels (above approximately 93%). The samples to be studied are placed in a pressurized container (an extractor) on a water...

  11. 21 CFR 878.4780 - Powered suction pump.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be used to remove infectious materials from wounds or fluids from a patient's airway or respiratory support system. The device may be used during surgery in the operating room or at the patient's bedside...

  12. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  13. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (FT/ : W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moistur...

  14. ASME code and ratcheting in piping components. Final technical report

    International Nuclear Information System (INIS)

    Hassan, T.; Matzen, V.C.

    1999-01-01

    The main objective of this research is to develop an analysis program which can accurately simulate ratcheting in piping components subjected to seismic or other cyclic loads. Ratcheting is defined as the accumulation of deformation in structures and materials with cycles. This phenomenon has been demonstrated to cause failure to piping components (known as ratcheting-fatigue failure) and is yet to be understood clearly. The design and analysis methods in the ASME Boiler and Pressure Vessel Code for ratcheting of piping components are not well accepted by the practicing engineering community. This research project attempts to understand the ratcheting-fatigue failure mechanisms and improve analysis methods for ratcheting predictions. In the first step a state-of-the-art testing facility is developed for quasi-static cyclic and seismic testing of straight and elbow piping components. A systematic testing program to study ratcheting is developed. Some tests have already been performed and the rest will be completed by summer'99. Significant progress has been made in the area of constitutive modeling. A number of sophisticated constitutive models have been evaluated in terms of their simulations for a broad class of ratcheting responses. From the knowledge gained from this evaluation study two improved models are developed. These models are demonstrated to have promise in simulating ratcheting responses in piping components. Hence, implementation of these improved models in widely used finite element programs, ANSYS and/or ABAQUS, is in progress. Upon achieving improved finite element programs for simulation of ratcheting, the ASME Code provisions for ratcheting of piping components will be reviewed and more rational methods will be suggested. Also, simplified analysis methods will be developed for operability studies of piping components and systems. Some of the future works will be performed under the auspices of the Center for Nuclear Power Plant Structures

  15. Sonographic measurements of the ulnar nerve at the elbow with different degrees of elbow flexion.

    Science.gov (United States)

    Patel, Prutha; Norbury, John W; Fang, Xiangming

    2014-05-01

    To determine whether there were differences in the cross-sectional area (CSA) and the flattening ratio of the normative ulnar nerve as it passes between the medial epicondyle and the olecranon at 30° of elbow flexion versus 90° of elbow flexion. Bilateral upper extremities of normal healthy adult volunteers were evaluated with ultrasound. The CSA and the flattening ratio of the ulnar nerve at the elbow as it passes between the medial epicondyle and the olecranon were measured, with the elbow flexed at 30° and at 90°, by 2 operators with varying ultrasound scanning experience by using ellipse and direct tracing methods. The results from the 2 different angles of elbow flexion were compared for each individual operator. Finally, intraclass correlations for absolute agreement and consistency between the 2 raters were calculated. An outpatient clinic room at a regional rehabilitation center. Twenty-five normal healthy adult volunteers. The mean CSA and the mean flattening ratio of the ulnar nerve at 30° of elbow flexion and at 90° of elbow flexion. First, for the ellipse method, the mean CSA of the ulnar nerve at 90° (9.93 mm(2)) was slightly larger than at 30° (9.77 mm(2)) for rater 1. However, for rater 2, the mean CSA of the ulnar nerve at 90° (6.80 mm(2)) was slightly smaller than at 30° (7.08 mm(2)). This was found to be statistically insignificant when using a matched pairs t test and the Wilcoxon signed-rank test, with a significance level of .05. Similarly, the difference between the right side and the left side was not statistically significant. The intraclass correlations for absolute agreement between the 2 raters were not very high due to different measurement locations, but the intraclass correlations for consistency were high. Second, for the direct tracing method, the mean CSA at 90° (7.26 mm(2)) was slightly lower than at 30° (7.48 mm(2)). This was found to be statistically nonsignificant when using the matched pairs t test and the

  16. New approach to the suction force at the leading edge of a profile with zero thickness

    NARCIS (Netherlands)

    Sparenberg, JA; de Jager, EM

    2004-01-01

    This paper considers the suction force at the leading edge of a profile with zero thickness in an incompressible and inviscid fluid flow. The theory is linear, and the approach to the suction force is from the innerside of the profile. It is shown that the suction force can be considered as an

  17. Measured residual stresses in overlay pipe weldments removed from service

    International Nuclear Information System (INIS)

    Shack, W.J.

    1985-02-01

    Surface and throughwall residual stresses were measured on an elbow-to-pipe weldment that had been removed from the Hatch-2 reactor about a year after the application of a weld overlay. The results were compared with experimental measurements on three mock-up weldments and with finite-element calculations. The comparison shows that there are significant differences in the form and magnitude of the residual stress distributions. However, even after more than a year of service, the residual stresses over most of the inner surface of the actual plant weldment with an overlay were strongly compressive. 3 refs., 7 figs

  18. Lateral collateral ligament of the elbow joint

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1996-01-01

    The structure and kinematics of the lateral collateral ligament of the elbow joint were investigated in 10 cadaveric specimens. The lateral collateral ligament was observed to be a distinct part of the lateral collateral ligament complex. It contains posterior fibers that pass through the annular....... Division of the posterolateral capsule caused no further laxity. Cutting the lateral collateral ligament induced a maximum laxity of 11.8 degrees at 110 degrees of flexion in forced varus and a maximum laxity of 20.6 degrees at 110 degrees of flexion in forced external rotation. The corresponding maximal...... posterior radial head translation was observed at 80 degrees to 100 degrees of flexion and was 5.7 mm in forced varus and 8.1 mm in forced external rotation. This study suggests the lateral collateral ligament to be an important stabilizer of the humeroulnar joint and the radial head in forced varus...

  19. Percutaneous ultrasonic tenotomy for chronic elbow tendinosis: a prospective study.

    Science.gov (United States)

    Barnes, Darryl E; Beckley, James M; Smith, Jay

    2015-01-01

    Elbow tendinopathy is the most common cause of elbow pain affecting active populations. Surgical excision is reserved for patients with refractory symptoms. Percutaneous ultrasonic tenotomy performed under local anesthesia also removes degenerated tissue and therefore provides an alternative treatment option to surgical excision. This investigation prospectively documented the safety and 1-year efficacy of ultrasonic percutaneous tenotomy performed by a single operator. Nineteen patients, aged 38 to 67 years, in whom >6 months of conservative management for medial (7) or lateral (12) elbow tendinopathy had failed were prospectively studied. All patients were treated with percutaneous ultrasonic tenotomy of the elbow by a single operator. Visual analog scale (VAS) for pain, the 11-item version of the Disabilities of the Arm, Shoulder, and Hand (Quick DASH) index, and the Mayo Elbow Performance Score (MEPS) were assessed by an independent observer before treatment and at 6 weeks, 3 months, 6 months, and 12 months after treatment. No procedural complications occurred. Total treatment time was elbow tendinopathy up to 1 year after the procedure. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Application of CT three-dimensional reconstruction in elbow injury

    International Nuclear Information System (INIS)

    Liang Wenhua; Qian Li

    2009-01-01

    Objective: To investigate the application of multi-slice spiral CT in fracture of elbow, and to study the value of different methods of the reconstruction. Methods: Thin line cross-section spiral CT scan was carried out in 13 cases with elbow injury, three-dimensional reconstruction was completed later. Several reconstructed image quality to display f the elbow fracture and dislocation were analyzed and compared. Results: 13 cases (17) elbow trauma included humeral media epicondyle fracture, humeral external epicondyle fracture, intercondylar fracture, olecranal fracture and radial head fracture. Among them, X-ray film showed negative in three sites, showed suspect fractures in 2 cases, and only showed single fracture in 2 cases. MPR reconstruction image could not only identify the diagnosis of fracture, but also provide further multi-angle display on fracture line and the extent of articular surface involvement. Surface reconstruction technology could exclude the impact of passive elbow flexion and display elbow injury more intuitively. Conclusion The elbow fracture dislocation could be showed clearly in multi-slice spiral CT, especially for complex fractures, with unmatched advantages compared to X-ray for clinical diagnosis and treatment determination. (authors)

  1. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  2. Assessment of wall-thinning in carbon steel pipe by using laser-generated guided wave

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Yong; Cho, Youn Ho; Lee, Joon Hyun [Pusan National University, School of Mechanical Engineering, Busan (Korea, Republic of)

    2010-10-15

    The objective of this research is to estimate the crack location and size of a carbon steel pipe by using a laser ultrasound guided wave for the wall thinning evaluation of an elbow. The wall thinning of the carbon steel pipe is one of the most serious problems in nuclear power plants, especially the wall thinning of the carbon steel elbow caused by Flow-Accelerated Corrosion (FAC). Therefore, a non-destructive inspection method of elbow is essential for the nuclear power plants to operate safely. The specimens used in this study were carbon steel elbows, which represented the main elements of real nuclear power plants. The shape of the wall thinning was an oval with a width of 120mm, a length of 80mm, and a depth of 5mm. The L(0,1) and L(0,2) modes variation of the ultrasound guided wave signal is obtained from the response of the laser generation/air-coupled detection ultrasonic hybrid system represent the characteristics of the defect. The trends of these characteristics and signal processing were use dto estimate the size and location of wall thinning

  3. Assessment of wall-thinning in carbon steel pipe by using laser-generated guided wave

    International Nuclear Information System (INIS)

    Kim, Do Yong; Cho, Youn Ho; Lee, Joon Hyun

    2010-01-01

    The objective of this research is to estimate the crack location and size of a carbon steel pipe by using a laser ultrasound guided wave for the wall thinning evaluation of an elbow. The wall thinning of the carbon steel pipe is one of the most serious problems in nuclear power plants, especially the wall thinning of the carbon steel elbow caused by Flow-Accelerated Corrosion (FAC). Therefore, a non-destructive inspection method of elbow is essential for the nuclear power plants to operate safely. The specimens used in this study were carbon steel elbows, which represented the main elements of real nuclear power plants. The shape of the wall thinning was an oval with a width of 120mm, a length of 80mm, and a depth of 5mm. The L(0,1) and L(0,2) modes variation of the ultrasound guided wave signal is obtained from the response of the laser generation/air-coupled detection ultrasonic hybrid system represent the characteristics of the defect. The trends of these characteristics and signal processing were use dto estimate the size and location of wall thinning

  4. Drill pipe bridge plug

    International Nuclear Information System (INIS)

    Winslow, D.W.; Brisco, D.P.

    1991-01-01

    This patent describes a method of stopping flow of fluid up through a pipe bore of a pipe string in a well. It comprises: lowering a bridge plug apparatus on a work string into the pipe string to a position where the pipe bore is to be closed; communicating the pipe bore below a packer of the bridge plug apparatus through the bridge plug apparatus with a low pressure zone above the packer to permit the fluid to flow up through the bridge plug apparatus; engaging the bridge plug apparatus with an internal upset of the pipe string; while the fluid is flowing up through the bridge plug apparatus, pulling upward on the work string and the bridge plug apparatus and thereby sealing the packer against the pipe bore; isolating the pipe bore below the packer from the low pressure zone above the packer and thereby stopping flow of the fluid up through the pipe bore; disconnecting the work string from the bridge plug apparatus; and maintaining the bridge plug apparatus in engagement with the internal upset and sealed against the pipe bore due to an upward pressure differential applied to the bridge plug apparatus by the fluid contained therebelow

  5. Myositis Ossificans Traumatica Causing Ankylosis of the Elbow

    OpenAIRE

    Kanthimathi, B.; Udhaya Shankar, S.; Arun Kumar, K.; Narayanan, V. L.

    2014-01-01

    Myositis ossificans traumatica is an unusual complication following a muscle contusion injury. A significantly large myositic mass causing ankylosis of the elbow is even rarer. We report a 13-year-old boy who presented with a 14-month history of a fixed elbow with no movement and a palpable bony mass in the anterior aspect of the elbow. He had sustained significant trauma to the affected limb 1 month prior to onset of symptoms, which was managed by native massage and bandaging for 4 weeks. Th...

  6. Long-term sequel of posterolateral rotatory instability of the elbow: a case report

    Directory of Open Access Journals (Sweden)

    Cheng Chun-Ying

    2010-01-01

    Full Text Available Abstract The natural course of untreated posterior lateral rotatory instability of the elbow is unclear. A case of elbow arthrosis with progressing deformity and flexion contracture after an episode of elbow dislocation about 20 years ago presented the possibility the long term outcome of untreated posterior lateral rotatory instability of the elbow.

  7. Suboptimal control for drag reduction in turbulent pipe flow

    International Nuclear Information System (INIS)

    Choi, Jung Il; Sung, Hyung Jin; Xu, Chun Xiao

    2001-01-01

    A suboptimal control law in turbulent pipe flow is derived and tested. Two sensing variables ∂ρ/∂θ / w and ∂ν θ /∂r / w are applied with two actuations φ θ and φ γ . To test the suboptimal control law, direct numerical simulations of turbulent pipe flow at Re τ =150 are performed. When the control law is applied, a 13∼23% drag reduction is achieved. The most effective drag reduction is made at the pair of ∂υ θ /∂r / w and φ γ . An impenetrable virtual wall concept is useful for analyzing the near-wall suction and blowing. The virtual wall concept is useful for analyzing the near-wall behavior of the controlled flow. Comparison of the present suboptimal control with that of turbulent channel flow reveals that the curvature effect is insignificant

  8. Evaluations of the piping system inelastic analysis computer program PIRAX2

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.

    1977-01-01

    The report contains two sets of comparisons of inelastic test data with PIRAX2-Theory; i.e., ORNL beam tests and ORNL elbow tests. The purpose of these comparisons is to evaluate the accuracy of the simplified analytical techniques used in PIRAX2. The test data are on structures that are much simpler than piping systems but provide a fundamental basis for comparison. The report includes an analysis of a 3-anchor piping system to illustrate the relative simplicity of PIRAX2 input/output data and relatively small computer running time. Some areas of needed improvements in PIRAX2 are discussed

  9. A lead-before-break strategy for primary heat transport piping of 500 MWe Indian PHWR

    Energy Technology Data Exchange (ETDEWEB)

    Chattopadhyay, J.; Dutta, B.K.; Kushwaha, H.S. [Bhabha Atomic Research Centre, Bombay (India)] [and others

    1997-04-01

    Leak-Before-Break (LBB) is being used to design the primary heat transport piping system of 500 MWe Indian Pressurized Heavy Water Reactors (IPHWR). The work is categorized in three directions to demonstrate three levels of safety against sudden catastrophic break. Level 1 is inherent in the design procedure of piping system as per ASME Sec.III with a well defined factor of safety. Level 2 consists of fatigue crack growth study of a postulated part-through flaw at the inside surface of pipes. Level 3 is stability analysis of a postulated leakage size flaw under the maximum credible loading condition. Developmental work related to demonstration of level 2 and level 3 confidence is described in this paper. In a case study on fatigue crack growth on PHT straight pipes for level 2, negligible crack growth is predicted for the life of the reactor. For level 3 analysis, the R6 method has been adopted. A database to evaluate SIF of elbows with throughwall flaws under combined internal pressure and bending moment has been generated to provide one of the inputs for R6 method. The methodology of safety assessment of elbow using R6 method has been demonstrated for a typical pump discharge elbow. In this analysis, limit load of the cracked elbow has been determined by carrying out elasto-plastic finite element analysis. The limit load results compared well with those given by Miller. However, it requires further study to give a general form of limit load solution. On the experimental front, a set of small diameter pipe fracture experiments have been carried out at room temperature and 300{degrees}C. Two important observations of the experiments are - appreciable drop in maximum load at 300{degrees}C in case of SS pipes and out-of-plane crack growth in case of CS pipes. Experimental load deflection curves are finally compared with five J-estimation schemes predictions. A material database of PHT piping materials is also being generated for use in LBB analysis.

  10. A lead-before-break strategy for primary heat transport piping of 500 MWe Indian PHWR

    International Nuclear Information System (INIS)

    Chattopadhyay, J.; Dutta, B.K.; Kushwaha, H.S.

    1997-01-01

    Leak-Before-Break (LBB) is being used to design the primary heat transport piping system of 500 MWe Indian Pressurized Heavy Water Reactors (IPHWR). The work is categorized in three directions to demonstrate three levels of safety against sudden catastrophic break. Level 1 is inherent in the design procedure of piping system as per ASME Sec.III with a well defined factor of safety. Level 2 consists of fatigue crack growth study of a postulated part-through flaw at the inside surface of pipes. Level 3 is stability analysis of a postulated leakage size flaw under the maximum credible loading condition. Developmental work related to demonstration of level 2 and level 3 confidence is described in this paper. In a case study on fatigue crack growth on PHT straight pipes for level 2, negligible crack growth is predicted for the life of the reactor. For level 3 analysis, the R6 method has been adopted. A database to evaluate SIF of elbows with throughwall flaws under combined internal pressure and bending moment has been generated to provide one of the inputs for R6 method. The methodology of safety assessment of elbow using R6 method has been demonstrated for a typical pump discharge elbow. In this analysis, limit load of the cracked elbow has been determined by carrying out elasto-plastic finite element analysis. The limit load results compared well with those given by Miller. However, it requires further study to give a general form of limit load solution. On the experimental front, a set of small diameter pipe fracture experiments have been carried out at room temperature and 300 degrees C. Two important observations of the experiments are - appreciable drop in maximum load at 300 degrees C in case of SS pipes and out-of-plane crack growth in case of CS pipes. Experimental load deflection curves are finally compared with five J-estimation schemes predictions. A material database of PHT piping materials is also being generated for use in LBB analysis

  11. Analysis of pressure wave transients and seismic response in LMFBR piping systems using the SHAPS code

    International Nuclear Information System (INIS)

    Zeuch, W.R.; Wang, C.Y.

    1985-01-01

    This paper presents some of the current capabilities of the three-dimensional piping code SHAPS and demonstrates their usefulness in handling analyses encountered in typical LMFBR studies. Several examples demonstrate the utility of the SHAPS code for problems involving fluid-structure interactions and seismic-related events occurring in three-dimensional piping networks. Results of two studies of pressure wave propagation demonstrate the dynamic coupling of pipes and elbows producing global motion and rigorous treatment of physical quantities such as changes in density, pressure, and strain energy. Results of the seismic analysis demonstrate the capability of SHAPS to handle dynamic structural response within a piping network over an extended transient period of several seconds. Variation in dominant stress frequencies and global translational frequencies were easily handled with the code. 4 refs., 10 figs

  12. Miniature Heat Pipes

    Science.gov (United States)

    1997-01-01

    Small Business Innovation Research contracts from Goddard Space Flight Center to Thermacore Inc. have fostered the company work on devices tagged "heat pipes" for space application. To control the extreme temperature ranges in space, heat pipes are important to spacecraft. The problem was to maintain an 8-watt central processing unit (CPU) at less than 90 C in a notebook computer using no power, with very little space available and without using forced convection. Thermacore's answer was in the design of a powder metal wick that transfers CPU heat from a tightly confined spot to an area near available air flow. The heat pipe technology permits a notebook computer to be operated in any position without loss of performance. Miniature heat pipe technology has successfully been applied, such as in Pentium Processor notebook computers. The company expects its heat pipes to accommodate desktop computers as well. Cellular phones, camcorders, and other hand-held electronics are forsible applications for heat pipes.

  13. On equations for the total suction and its matric and osmotic components

    International Nuclear Information System (INIS)

    Dao, Vinh N.T.; Morris, Peter H.; Dux, Peter F.

    2008-01-01

    A clear fundamental understanding of suctions is crucial for the study of the behaviour of plastic cement mortar and concrete, including plastic shrinkage cracking. In this paper, the expression relating the change in free energy of the pore water with an isothermal change in pressure is first derived. Based upon definitions of suctions, it is then shown that total, matric, and osmotic suctions can all be expressed in the same thermodynamic form. The widely accepted, but not yet satisfactorily validated, assumption that the total suction comprises matric and osmotic components is then confirmed theoretically. The well-known Kelvin equation for matric suction, and Morse and van't Hoff equations for osmotic suction are subsequently derived from the corresponding thermodynamic equations. The applicability of latter two equations in evaluating the osmotic suctions of cement mortar and concrete is highlighted

  14. Report on technical measurements concerning measurement of the suction of tanks at Fangel biomass conversion plant

    International Nuclear Information System (INIS)

    1992-05-01

    The inconveniences caused by the odours emerging from the biomass conversion plant in Fangel, Denmark, and the actions taken in an attempt to reduce them, are described. The plant has on several occasions been threatened with being closed down because of the smell. Airtight coverings have been fixed on all the open tanks, and the suction element has been tested to see if it is airtight. Ozone has been added in order to help get rid of the smell. Measurements have shown that it is possible to attain a small vacuum in the storage tank under normal operation, if there is a surfeit of pumping there will be too high pressure. In relation to pumping-in the pressure can be too high in the first and medium tank. Flow, pressure, hydrogen sulphide and methane concentration changes significantly in relation to the various pumping frequences. The level of hydrogen sulphide removal in the biofilter was 70-85%. The flow of hydrogen sulphide becomes less after the addition of ozone. Measurements implied that the tanks were airtight. Larger vacuums can be achieved by changing the shape of the pipe system and increasing the flow. (AB)

  15. Safety System for Controlling Fluid Flow into a Suction Line

    Science.gov (United States)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2018-01-01

    A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.

  16. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  17. The application of suction caisson technology to offshore wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    A mathematical model describing the behaviour of caisson foundations for offshore wind turbines has been developed. The model has been verified and calibrated through laboratory and field work. Simultaneously, conceptual designs of wind turbine foundations incorporating suction caissons were studied using the same model. It was concluded that much of the seabed around Britain is well suited to the use of caissons and monopod and quadropod structures are superior to tripods. Although suction caissons are vulnerable to scour, rock dumping can largely eliminate this potential problem. The next phase will be to install a fully instrumented full-scale prototype to monitor the effects of wind and waves. The main contractor was SLP Engineering Limited and about 75 per cent of the funding came from the DTI.

  18. Acute and overuse elbow trauma: radio-orthopaedics overview.

    Science.gov (United States)

    Nocerino, Elisabetta Antonia; Cucchi, Davide; Arrigoni, Paolo; Brioschi, Marco; Fusi, Cristiano; Genovese, Eugenio A; Messina, Carmelo; Randelli, Pietro; Masciocchi, Carlo; Aliprandi, Alberto

    2018-01-19

    The correct management of acute, subacute and overuse-related elbow pathologies represents a challenging diagnostic and therapeutic problem. While major trauma frequently requires a rapid surgical intervention, subluxation and minor trauma allow taking more time for diagnostics and planning the correct elective treatment after careful clinical and radiological investigation. In these conditions, communication between orthopaedic surgeon and radiologist allow to create a detailed radiology report, tailored to the patient's and surgeon's needs and optimal to plan proper management. Imaging technique as X-Ray, CT, US, MRI, CTA and MRA all belong to the radiologist's portfolio in elbow diagnostics. Detailed knowledge of elbow pathology and its classification and of the possibilities and limits of each imaging technique is of crucial importance to reach the correct diagnosis efficiently. The aim of this review is to present the most frequent elbow pathologies and suggest a suitable diagnostic approach for each of them.

  19. Golf Injuries to the Hand, Wrist, or Elbow

    Science.gov (United States)

    ... Therapist? Media Find a Hand Surgeon Home Anatomy Golf Injuries to the Hand, Wrist or Elbow Email ... enjoyment of the game injury free. Types of Golf Injuries Golf injuries can include tendonitis, sprains or ...

  20. Dry Arthroscopy of the Elbow and Basic Hip Arthroscopy Positioning.

    Science.gov (United States)

    Lubowitz, James H

    2015-08-01

    In Arthroscopy Techniques, dry arthroscopy of the elbow is well-illustrated, and hip arthroscopy patient positioning including fluoroscopic examination under anesthesia is critically reviewed. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Diagnosing ulnar neuropathy at the elbow using magnetic resonance neurography

    International Nuclear Information System (INIS)

    Keen, Nayela N.; Chin, Cynthia T.; Saloner, David; Steinbach, Lynne S.; Engstrom, John W.

    2012-01-01

    Early diagnosis of ulnar neuropathy at the elbow is important. Magnetic resonance neurography (MRN) images peripheral nerves. We evaluated the usefulness of elbow MRN in diagnosing ulnar neuropathy at the elbow. The MR neurograms of 21 patients with ulnar neuropathy were reviewed retrospectively. MRN was performed prospectively on 10 normal volunteers. The MR neurograms included axial T1 and axial T2 fat-saturated and/or axial STIR sequences. The sensitivity and specificity of MRN in detecting ulnar neuropathy were determined. The mean ulnar nerve size in the symptomatic and normal groups was 0.12 and 0.06 cm 2 (P 2 , sensitivity was 95% and specificity was 80%. Ulnar nerve size and signal intensity were greater in patients with ulnar neuropathy. MRN is a useful test in evaluating ulnar neuropathy at the elbow. (orig.)

  2. Elbow joint stability in relation to forced external rotation

    DEFF Research Database (Denmark)

    Deutch, S.R.; Jensen, S.L.; Olsen, B.S.

    2003-01-01

    The objective of this study was to evaluate the osseous constraint related to forced forearm external rotation as the initial stage in a posterior elbow dislocation. Six joint specimens without soft tissues were examined in a joint analysis system developed for simulation of dislocation. The osse......The objective of this study was to evaluate the osseous constraint related to forced forearm external rotation as the initial stage in a posterior elbow dislocation. Six joint specimens without soft tissues were examined in a joint analysis system developed for simulation of dislocation...... external forearm rotation until the point of maximal torque decreased from a maximum in full extension to a minimum at 30 degrees of elbow flexion (P =.03). The elbow in a slightly flexed position, varus stress, and forearm external rotation trauma might be the important biomechanical factors...

  3. Introduction to Heat Pipes

    Science.gov (United States)

    Ku, Jentung

    2015-01-01

    This is the presentation file for the short course Introduction to Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. NCTS 21070-15. Course Description: This course will present operating principles of the heat pipe with emphases on the underlying physical processes and requirements of pressure and energy balance. Performance characterizations and design considerations of the heat pipe will be highlighted. Guidelines for thermal engineers in the selection of heat pipes as part of the spacecraft thermal control system, testing methodology, and analytical modeling will also be discussed.

  4. Riser pipe elevator

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, W.; Jimenez, A.F.

    1987-09-08

    This patent describes a method for storing and retrieving a riser pipe, comprising the steps of: providing an upright annular magazine comprised of an inside annular wall and an outside annular wall, the magazine having an open top; storing the riser pipe in a substantially vertically oriented position within the annular magazine; and moving the riser pipe upwardly through the open top of the annular magazine at an angle to the vertical along at least a portion of the length of the riser pipe.

  5. Piping engineering and operation

    International Nuclear Information System (INIS)

    1993-01-01

    The conference 'Piping Engineering and Operation' was organized by the Institution of Mechanical Engineers in November/December 1993 to follow on from similar successful events of 1985 and 1989, which were attended by representatives from all sectors of the piping industry. Development of engineering and operation of piping systems in all aspects, including non-metallic materials, are highlighted. The range of issues covered represents a balance between current practices and implementation of future international standards. Twenty papers are printed. Two, which are concerned with pressurized pipes or steam lines in the nuclear industry, are indexed separately. (Author)

  6. Piping equipment; Materiel petrole

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This 'blue bible' of the perfect piping-man appeals to end-users of industrial facilities of the petroleum and chemical industries (purchase services, standardization, new works, maintenance) but also to pipe-makers and hollow-ware makers. It describes the characteristics of materials (carbon steels, stainless steels, alloyed steels, special alloys) and the dimensions of pipe elements: pipes, welding fittings, flanges, sealing products, forged steel fittings, forged steel valves, cast steel valves, ASTM standards, industrial valves. (J.S.)

  7. A review of epidemiology of paediatric elbow injuries in sports.

    Science.gov (United States)

    Magra, Merzesh; Caine, Dennis; Maffulli, Nicola

    2007-01-01

    The elbow is a common site of orthopaedic injury in the paediatric population. The number of these injuries continues to rise following increased levels of participation in paediatric recreational and competitive sport. Injuries to the paediatric elbow can be classified as either overuse or acute. Delineating injury patterns to the elbow in children can be challenging, given the cartilaginous composition of the distal humerus and the multiple secondary ossification centres that appear and unite with the epiphysis at defined ages. Pitching in baseball, serving in tennis, spiking in volleyball, passing in American football and launching in javelin-throwing can all produce elbow pathology by forceful valgus stress, with medial stretching, lateral compression and posterior impingement. In children and adolescents, the epiphyseal plate is weaker than the surrounding ligaments, predisposing them to epiphyseal plate injuries. On the other hand, post-pubescent or skeletally mature athletes are more prone to tendinous or ligamentous injury. Injuries may cause significant impact on the athlete, parents and healthcare system. With the exception of baseball, there are few prospective cohort studies on the epidemiological trends of childhood elbow injuries in other sports. This paper aims to describe the epidemiological trends in paediatric elbow injuries related to sports, suggests prevention strategies and discusses the scope for further research. A web-based search of existing articles pertaining to paediatric elbow injuries in sports was performed. The implications of acute and overuse injuries and the possibility of permanent damage should be understood by parents, coaches and the athletes. Proper understanding of the intrinsic and extrinsic risk factors that could lead to elbow injuries is thus required. Measures to prevent elbow injuries should include proper coaching, warm-up, officiation, legislation, medical expertise and protective gear. There are still many

  8. Review of pump suction reducer selection: Eccentric or concentric reducers

    OpenAIRE

    Mahaffey, R M; van Vuuren, S J

    2014-01-01

    Eccentric reducers are traditionally recommended for the pump suction reducer fitting to allow for transportation of air through the fitting to the pump. The ability of a concentric reducer to provide an improved approach flow to the pump while still allowing air to be transported through the fitting is investigated. Computational fluid dynamics (CFD) were utilised to analyse six concentric and six eccentric reducer geometries at four different inlet velocities to determine the flow velocity ...

  9. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    OpenAIRE

    AZZEDINE NAHOUI; LAKHDAR BAHI

    2013-01-01

    A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has de...

  10. Modelling suction instabilities in soils at varying degrees of saturation

    Directory of Open Access Journals (Sweden)

    Buscarnera Giuseppe

    2016-01-01

    Full Text Available Wetting paths imparted by the natural environment and/or human activities affect the state of soils in the near-surface, promoting transitions across different regimes of saturation. This paper discusses a set of techniques aimed at quantifying the role of hydrologic processes on the hydro-mechanical stability of soil specimens subjected to saturation events. Emphasis is given to the mechanical conditions leading to coupled flow/deformation instabilities. For this purpose, energy balance arguments for three-phase systems are used to derive second-order work expressions applicable to various regimes of saturation. Controllability analyses are then performed to relate such work input with constitutive singularities that reflect the loss of strength under coupled and/or uncoupled hydro-mechanical forcing. A suction-dependent plastic model is finally used to track the evolution of stability conditions in samples subjected to wetting, thus quantifying the growth of the potential for coupled failure modes upon increasing degree of saturation. These findings are eventually linked with the properties of the field equations that govern pore pressure transients, thus disclosing a conceptual link between the onset of coupled hydro-mechanical failures and the evolution of suction with time. Such results point out that mathematical instabilities caused by a non-linear suction dependent behaviour play an important role in the advanced constitutive and/or numerical tools that are commonly used for the analysis of geomechanical problems in the unsaturated zone, and further stress that the relation between suction transients and soil deformations is a key factor for the interpretation of runaway failures caused by intense saturation events.

  11. Abdominal drainage following cholecystectomy: high, low, or no suction?

    OpenAIRE

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study f...

  12. The medial collateral ligament of the elbow joint

    DEFF Research Database (Denmark)

    Floris, S; Olsen, Bo Sanderhoff; Dalstra, Michel

    1998-01-01

    Eighteen osteoligamentous elbow joint specimens were included in a study of the medial collateral ligament complex (MCL). The morphologic characteristics of the MCL were examined, and three-dimensional kinematic measurements were taken after selective ligament dissections were performed. On morph......Eighteen osteoligamentous elbow joint specimens were included in a study of the medial collateral ligament complex (MCL). The morphologic characteristics of the MCL were examined, and three-dimensional kinematic measurements were taken after selective ligament dissections were performed...

  13. Energy transformation and flow topology in an elbow draft tube

    Directory of Open Access Journals (Sweden)

    Štefan D.

    2012-06-01

    Full Text Available Paper presents a computational study of energy transformation in two geometrical configurations of Kaplan turbine elbow draft tube. Pressure recovery, hydraulic efficiency and loss coefficient are evaluated for a series of flow rates and swirl numbers corresponding to operating regimes of the turbine. These integral characteristics are then correlated with local flow field properties identified by extraction of topological features. Main focus is to find the reasons for hydraulic efficiency drop of the elbow draft tube.

  14. Elbow joint fatigue and bench-press training.

    Science.gov (United States)

    Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2014-01-01

    Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Controlled laboratory study. Motion research laboratory. A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Participants performed bench-press training until fatigued. Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should control carefully the maximal number of repetitions.

  15. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  16. Development of engineering program for integrity evaluation of pipes with local wall thinned defects

    International Nuclear Information System (INIS)

    Park, Chi Yong; Lee, Sung Ho; Kim, Tae Ryong; Park, Sang Kyu

    2008-01-01

    Integrity evaluation of pipes with local wall thinning by erosion and corrosion is increasingly important in maintenance of wall thinned carbon steel pipes in nuclear power plants. Though a few program for integrity assessment of wall thinned pipes have been developed in domestic nuclear field, however those are limited to straight pipes and methodology proposed in ASME Sec.XI Code Case N-597. Recently, the engineering program for integrity evaluation of pipes with all kinds of local wall defects such as straight, elbow, reducer and branch pipes was developed successfully. The program was designated as PiTEP (Pipe Thinning Evaluation Program), which name was registered as a trademark in the Korea Intellectual Property Office. A developed program is carried out by sequential step of four integrity evaluation methodologies, which are composed of construction code, code case N-597, its engineering method and two developed owner evaluation method. As PiTEP program will be performed through GUI (Graphic User Interface) with user's familiarity, it would be conveniently used by plant engineers with only measured thickness data, basic operation conditions and pipe data

  17. Deliberate utilization of interaction torques brakes elbow extension in a fast throwing motion.

    Science.gov (United States)

    Hore, Jon; Debicki, Derek B; Gribble, Paul L; Watts, Sherry

    2011-05-01

    We tested the hypothesis that in fast arm movements the CNS deliberately utilizes interaction torques to decelerate (brake) joint rotations. Twelve subjects performed fast 2-D overarm throws in which large elbow extension velocities occurred. Joint motions were computed from recordings made with search coils; joint torques were calculated using inverse dynamics. After ball release, a large follow-through shoulder extension acceleration occurred that was initiated by shoulder extensor muscle torque. This shoulder acceleration produced a flexor interaction torque at the elbow that initiated elbow deceleration (braking). An instantaneous mechanical interaction of passive torques then occurred between elbow and shoulder, i.e., elbow extension deceleration produced a large shoulder extensor interaction torque that contributed to the shoulder extension acceleration which, simultaneously, produced a large elbow flexor interaction torque that contributed to elbow extension deceleration, and so on. Late elbow flexor muscle torque also contributed to elbow deceleration. The interaction of passive torques between shoulder and elbow was braked by shoulder flexor muscle torque. In this mechanism, shoulder musculature contributed to braking elbow extension in two ways: shoulder extensors initiated the mechanical interaction of passive torques between shoulder and elbow and shoulder flexors dissipated kinetic energy from elbow braking. It is concluded that, in fast 2-D throws, the CNS deliberately utilizes powerful interaction torques between shoulder and elbow to brake motion at the elbow.

  18. Effects of shallow and deep endotracheal tube suctioning on cardiovascular indices in patients in intensive care units.

    Science.gov (United States)

    Irajpour, Alireza; Abbasinia, Mohammad; Hoseini, Abbas; Kashefi, Parviz

    2014-07-01

    Clearing the endotracheal tube through suctioning should be done to promote oxygenation. Depth of suctioning is one of the variables in this regard. In shallow suctioning method, the catheter passes to the tip of the endotracheal tube, and in deep suctioning method, it passes beyond the tip into the trachea or brunches. This study aimed to evaluate the effect of shallow and deep suctioning methods on cardiovascular indices in patients hospitalized in the intensive care units (ICUs). In this clinical trial, 74 patients were selected among those who had undergone mechanical ventilation in the ICU of Al-Zahra Hospital, Isfahan, Iran using convenience sampling method. The subjects were randomly allocated to shallow and deep suctioning groups. Heart rate (HR) and blood pressure (BP) were measured immediately before and 1, 2, and 3 min after each suctioning. Number of times of suctioning was also noted in both the groups. Data were analyzed using repeated measures analysis of variance (ANOVA), Chi-square and independent t-tests. HR and BP were significantly increased after suctioning in both the groups (P 0.05). The suctioning count was significantly higher in the shallow suctioning group than in the deep suctioning group. Shallow and deep suctioning were similar in their effects on HR and BP, but shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, in order to prevent complications, nurses are recommended to perform the endotracheal tube suctioning by the deep method.

  19. Modulation method of scroll compressor based on suction gas bypass

    International Nuclear Information System (INIS)

    Wang Baolong; Han Linjun; Shi Wenxing; Li Xianting

    2012-01-01

    The air conditioners and heat pumps tend to work in much mild environments and part load situations rather than provide the rated full capacity under severe rated testing conditions. Both the capacity and inner compression ratio of the compressor should be regulated according to the working condition for higher energy efficiency and occupants’ comfort. A potential modulating technology of the scroll compressor, suction gas bypass, is investigated in this paper. The principle and operation method are illuminated and the adaptability is validated by experiments and simulations. As a conclusion, an appropriate suction gas bypass can reduce the inner compression loss of the scroll compressor under over compression conditions, enhance the system COP and also largely decrease the heating/cooling capacity of the refrigeration/heat pump system. - Highlights: ► Suction gas bypass (SGB) is an effective regulating method of scroll compressor. ► SGB reduces the inner compression loss under over compression conditions. ► SGB largely decreases the heating/cooling capacity of the refrigeration system.

  20. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  1. Reliable site for suction blister induction and harvesting

    Directory of Open Access Journals (Sweden)

    Laxmisha Chandrashekar

    2005-01-01

    Full Text Available Background: Suction blister grafting is a useful modality of treatment of patients with resistant and stable vitiligo. However, there have been no detailed studies to find out the best donor site for blister formation. Methods: The study was conducted between the period of October 2004 and February 2005 in the dermatology department at a tertiary care center. Nine patients with vitiligo (focal vitiligo, 3; mucosal vitiligo, 2; acrofacial vitiligo, 2; vitiligo vulgaris, 1; and segmental vitiligo, 1 were selected for blister harvesting and grafting. The blisters were raised using the method described by Gupta et al. Results: Suction blisters were attempted to be raised at 52 sites, but only 38 blisters could be raised, 24 complete and 14 incomplete. Blisters were raised in all the three cases on the flexor aspect of the arm (100%, 15 of 17 cases (88.2% on the flexor aspect of the forearm, 4 of 5 cases (80% on the abdomen, 11 of 16 cases (68.7% on the anterolateral thigh, and less frequently over leg or foot. Complete blisters were formed in 13/15 cases (86.6% on the flexor aspect of the forearm, 6/11 cases (54.5% on the anterolateral thigh, and in all cases over leg. Conclusion: The flexor aspect of the forearm is a good site for suction blister harvesting.

  2. Anatomic factors related to the cause of tennis elbow.

    Science.gov (United States)

    Bunata, Robert E; Brown, David S; Capelo, Roderick

    2007-09-01

    The pathogenesis of lateral epicondylitis remains unclear. Our purpose was to study the anatomy of the lateral aspect of the elbow under static and dynamic conditions in order to identify bone-to-tendon and tendon-to-tendon contact or rubbing that might cause abrasion of the tissues. Eighty-five cadaveric elbows were examined to determine details related to the bone structure and musculotendinous origins. We identified the relative positions of the musculotendinous units and the underlying bone when the elbow was in different degrees of flexion. We also recorded the contact between the extensor carpi radialis brevis and the lateral edge of the capitellum as elbow motion occurred, and we sought to identify the areas of the capitellum and extensor carpi radialis brevis where contact occurs. The average site of origin of the extensor carpi radialis brevis on the humerus lay slightly medial and superior to the outer edge of the capitellum. As the elbow was extended, the undersurface of the extensor carpi radialis brevis rubbed against the lateral edge of the capitellum while the extensor carpi radialis longus compressed the brevis against the underlying bone. The extensor carpi radialis brevis tendon has a unique anatomic location that makes its undersurface vulnerable to contact and abrasion against the lateral edge of the capitellum during elbow motion.

  3. Elbow joint position sense after neuromuscular training with handheld vibration.

    Science.gov (United States)

    Tripp, Brady L; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.

  4. Elbow flexor and extensor muscle weakness in lateral epicondylalgia.

    Science.gov (United States)

    Coombes, Brooke K; Bisset, Leanne; Vicenzino, Bill

    2012-05-01

    To evaluate whether deficits of elbow flexor and extensor muscle strength exist in lateral epicondylalgia (LE) in comparison with a healthy control population. Cross-sectional study. 150 participants with unilateral LE were compared with 54 healthy control participants. Maximal isometric elbow flexion and extension strength were measured bilaterally using a purpose-built standing frame such that gripping was avoided. The authors found significant side differences in elbow extensor (-6.54 N, 95% CI -11.43 to -1.65, p=0.008, standardised mean difference (SMD) -0.45) and flexor muscle strength (-11.26 N, 95% CI -19.59 to -2.94, p=0.009, SMD -0.46) between LE and control groups. Within the LE group, only elbow extensor muscle strength deficits between sides was significant (affected-unaffected: -2.94 N, 95% CI -5.44 to -0.44). Small significant deficits of elbow extensor and flexor muscle strength exist in the affected arm of unilateral LE in comparison with healthy controls. Notably, comparing elbow strength between the affected and unaffected sides in unilateral epicondylalgia is likely to underestimate these deficits. Trial Registration Australian New Zealand Clinical Trials Register ACTRN12609000051246.

  5. The Reasons of Steam Pipeline Elbow Rupture

    Directory of Open Access Journals (Sweden)

    Mesjasz A.

    2016-09-01

    Full Text Available In the paper the reasons for steam pipeline’s elbow material rupture, made of steel 13CrMo4-5 (15HM that is being used in the energetics. Based on the mechanical properties in the ambient temperature (Rm, Rp0,2 and elongation A5 and in the increased temperature (Rp0,2t it was found, that the pipeline elbow’s material sampled from the ruptured area has lower Rp0,2 i Rp0,2t by around 2% than it is a requirement for 13CrMo4-5 steel in it’s base state. The damage appeared as a result of complex stress state, that substantially exceeded the admissible tensions, what was the consequence of considerable structure degradation level. As a result of the microstructure tests on HITACHI S4200 microscope, the considerable development of the creeping process associates were found. Also the advances progress of the microstructure degradation was observed, which is substantial decomposition of bainite and multiple, with varied secretion size, and in most cases forming the micro cracks chains. With the use of lateral micro sections the creeping voids were observed, that creates at some places the shrinkage porosities clusters and micro pores.

  6. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  7. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  8. Transients in pipes

    International Nuclear Information System (INIS)

    Marchesin, D.; Paes-Leme, P.J.S.; Sampaio, R.

    1981-01-01

    The motion of a fluid in a pipe is commonly modeled utilizing the one space dimension conservation laws of mass and momentum. The development of shocks and spikes utilizing the uniform sampling method is studied. The effects of temperature variations and friction are compared for gas pipes. (Author) [pt

  9. These Pipes Are "Happening"

    Science.gov (United States)

    Skophammer, Karen

    2010-01-01

    The author is blessed with having the water pipes for the school system in her office. In this article, the author describes how the breaking of the pipes had led to a very worthwhile art experience for her students. They practiced contour and shaded drawing techniques, reviewed patterns and color theory, and used their reasoning skills--all while…

  10. Piping research program plan

    International Nuclear Information System (INIS)

    1988-09-01

    This document presents the piping research program plan for the Structural and Seismic Engineering Branch and the Materials Engineering Branch of the Division of Engineering, Office of Nuclear Regulatory Research. The plan describes the research to be performed in the areas of piping design criteria, environmentally assisted cracking, pipe fracture, and leak detection and leak rate estimation. The piping research program addresses the regulatory issues regarding piping design and piping integrity facing the NRC today and in the foreseeable future. The plan discusses the regulatory issues and needs for the research, the objectives, key aspects, and schedule for each research project, or group of projects focussing of a specific topic, and, finally, the integration of the research areas into the regulatory process is described. The plan presents a snap-shot of the piping research program as it exists today. However, the program plan will change as the regulatory issues and needs change. Consequently, this document will be revised on a bi-annual basis to reflect the changes in the piping research program. (author)

  11. Use of the Liverpool Elbow Score as a postal questionnaire for the assessment of outcome after total elbow arthroplasty.

    Science.gov (United States)

    Ashmore, Alexander M; Gozzard, Charles; Blewitt, Neil

    2007-01-01

    The Liverpool Elbow Score (LES) is a newly developed, validated elbow-specific score. It consists of a patient-answered questionnaire (PAQ) and a clinical assessment. The purpose of this study was to determine whether the PAQ portion of the LES could be used independently as a postal questionnaire for the assessment of outcome after total elbow arthroplasty and to correlate the LES and the Mayo Elbow Performance Score (MEPS). A series of 51 total elbow replacements were reviewed by postal questionnaire. Patients then attended the clinic for assessment by use of both the LES and the MEPS. There was an excellent response rate to the postal questionnaire (98%), and 44 elbows were available for clinical review. Good correlation was shown between the LES and the MEPS (Spearman correlation coefficient, 0.84; P PAQ portion of the LES and the MEPS (Spearman correlation coefficient, 0.76; P PAQ component and the MEPS, suggesting that outcome assessment is possible by postal questionnaire.

  12. Oscillating heat pipes

    CERN Document Server

    Ma, Hongbin

    2015-01-01

    This book presents the fundamental fluid flow and heat transfer principles occurring in oscillating heat pipes and also provides updated developments and recent innovations in research and applications of heat pipes. Starting with fundamental presentation of heat pipes, the focus is on oscillating motions and its heat transfer enhancement in a two-phase heat transfer system. The book covers thermodynamic analysis, interfacial phenomenon, thin film evaporation,  theoretical models of oscillating motion and heat transfer of single phase and two-phase flows, primary  factors affecting oscillating motions and heat transfer,  neutron imaging study of oscillating motions in an oscillating heat pipes, and nanofluid’s effect on the heat transfer performance in oscillating heat pipes.  The importance of thermally-excited oscillating motion combined with phase change heat transfer to a wide variety of applications is emphasized. This book is an essential resource and learning tool for senior undergraduate, gradua...

  13. MR arthrography of elbow: evaluation of the ulnar collateral ligament of elbow

    International Nuclear Information System (INIS)

    Nakanishi, Katsunuki; Masatomi, Takashi; Ochi, Takahiro; Ishida, Takeshi; Hori, Shinichi; Ikezoe, Junpei; Nakamura, Hironobu

    1996-01-01

    Objective. The purpose of this study was to evaluate ulnar collateral ligament (UCL) injury of the elbow in throwing athletes by MRI and MR arthrography. Design. Ten elbows of throwing athletes were examined on both plain MRI and MR saline arthrography and the injuries subsequently surgically proven. Spin-echo (SE) T1-weighted and fast SE T2-weighted coronal images were obtained. Results. The UCL was unclear in all ten cases on T1-weighted MRI. In five cases an avulsion fracture was also found on T1-weighted MRI. On T2-weighted MRI, abnormal high-intensity areas were identified in or around the UCL. On T2-weighted MR arthrography images, extracapsular high-intensity areas, which represent extracapsular leakage, were found in four of five cases with avulsion fracture. At surgery, all these four cases showed avulsion fractures with instability; the other case had a fracture but it was stable and adherent to the humerus. On T2-weighted MR arthrography images, an extracapsular high-intensity area was found in one of the five cases without avulsion fracture. At surgery this patient had a complete tear of the UCL itself. Conclusion. MR arthrography provided additional information for evaluating the degree of UCL injury. (orig.). With 5 figs., 1 tab

  14. Elbow Reconstruction Using Island Flap for Burn Patients

    Directory of Open Access Journals (Sweden)

    Gi Yeun Hur

    2012-11-01

    Full Text Available BackgroundDeep burns of the elbow lead to soft tissue necrosis and infection, with exposure of deep structures. Adequate wound coverage of this area requires thin, pliable, and durable tissue, while optimal functional recovery requires early coverage and functional rehabilitation. We have found 3 types of island flaps that provide reliable coverage for the elbow.MethodsA retrospective study was performed on all patients who underwent flap coverage of an elbow defect at our hospital. The patients' data including age, sex, cause of injury, wound dimensions, timing of flap coverage, postoperative elbow motion, and complications were investigated.ResultsBetween 2001 and 2012, 16 patients were treated at our hospital. The mean age was 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral arm flaps, and 4 radial forearm flaps. The average defect size was 183.5 cm2 (range, 28 to 670 cm2. Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days. The mean postoperative active elbow flexion was 98° (range, 85° to 115°. Partial flap failure occurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%, hematoma (23.5%, seroma (35.3%, and wound infection (5.9%.ConclusionsFlap selection for elbow reconstruction is determined by the defect size and the extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a single-staged, reliable, and relatively simple procedure that permits initiation of early rehabilitation, thereby improving a patient's functional outcome.

  15. Elbow Reconstruction Using Island Flap for Burn Patients

    Directory of Open Access Journals (Sweden)

    Gi Yeun Hur

    2012-11-01

    Full Text Available Background Deep burns of the elbow lead to soft tissue necrosis and infection, with exposureof deep structures. Adequate wound coverage of this area requires thin, pliable, and durabletissue, while optimal functional recovery requires early coverage and functional rehabilitation.We have found 3 types of island flaps that provide reliable coverage for the elbow.Methods A retrospective study was performed on all patients who underwent flap coverageof an elbow defect at our hospital. The patients’ data including age, sex, cause of injury, wounddimensions, timing of flap coverage, postoperative elbow motion, and complications wereinvestigated.Results Between 2001 and 2012, 16 patients were treated at our hospital. The mean agewas 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral armflaps, and 4 radial forearm flaps. The average defect size was 183.5 cm2 (range, 28 to 670cm2. Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days.The mean postoperative active elbow flexion was 98° (range, 85° to 115°. Partial flap failureoccurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%,hematoma (23.5%, seroma (35.3%, and wound infection (5.9%.Conclusions Flap selection for elbow reconstruction is determined by the defect size andthe extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a singlestaged,reliable, and relatively simple procedure that permits initiation of early rehabilitation,thereby improving a patient’s functional outcome.

  16. Inverted 'V' osteotomy excision arthroplasty for bony ankylosed elbows

    Directory of Open Access Journals (Sweden)

    Rex Chadrabose

    2011-12-01

    Full Text Available Abstract Background Bony ankylosis of elbow is challenging and difficult problem to treat. The options are excision arthroplasty and total elbow replacement. We report our midterm results on nine patients, who underwent inverted 'V' osteotomy excision arthroplasty in our hospital with good functional results. Materials Our case series includes 9 patients (seven males and two females with the mean age of 34 years (13-56 years. Five patients had trauma, two had pyogenic arthritis, one had tuberculous arthritis, and one had pyogenic arthritis following surgical fixation. Results The average duration of follow up is 65 months (45 months-80 months. The mean Mayo's elbow performance score (MEPS preoperatively was 48 (35-70. The MEPS at final follow up was 80 (60-95. With no movement at elbow and fixed in various degrees of either flexion or extension preoperatively, the mean preoperative position of elbow was 64°(30°to 100°. The mean post operative range of motion at final follow up was 27°of extension (20-500, 116°of flexion (1100-1300, and the arc of motion was 88°(800-1000. One patient had ulnar nerve neuropraxia and another patient developed median nerve neuropraxia, and both recovered completely in six weeks. No patient had symptomatic instability of the elbow. All patients were asymptomatic except one patient, who had pain mainly on heavy activities. Conclusion We conclude that inverted 'V' osteotomy excision arthroplasty is a viable option in the treatment of bony ankylosis of the elbow in young patients.

  17. Flow induced vibrations in a PWR piping system

    International Nuclear Information System (INIS)

    Seligmann, D.; Guillou, J.

    1995-11-01

    During a recurring bench test of an operating system, high amplitude vibrations have been observed on a safety piping system of a nuclear power plant. Due to the source of the pumps, these vibrations lead to wear damage and it is therefore necessary to estimate the life time of the piping system. This paper describes the methodology used to study the dynamic behaviour and to analyze the damage of a piping system submitted to internal flow. Starting from an experimental modal analysis of the piping system when not i service, we analyse the main parameters of the mechanical behaviour. Following this analysis, we obtain a mechanical model fitting the first experimental modes. On this basis, we build a vibro-acoustical model. This model takes into account the influence of the acoustical pipe length, both above and below the mechanical part, the modelling of acoustical components, the speed of sound. We did not experimentally characterize the pumps. Therefore, we use a numerical model in order to simulate the behaviour of the pumps. This model is based on the theory of the transfer matrix and takes into account the geometric and the hydraulic characteristics of the pump.The modelling of both sources (suction and discharge) connected to the pump is formed by contributions from a source corresponding to the turbulent noise at low frequency, a source at blade passage frequency. This model has been experimentally validated in a laboratory. The final results of the modelling of the complete piping system are in a complete accord with experimental measurements. (author). 3 refs., 7 figs

  18. Comparative study of the characteristics of some suction devices for gas sampling applications

    International Nuclear Information System (INIS)

    Donguy, R.; Drouet, J.

    1959-06-01

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc

  19. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    OpenAIRE

    Pekkan, Kerem; Uslu, Fazıl E.; Chang, Brain; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-01-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larv...

  20. CFD Analysis of a Centrifugal Fan for Performance Enhancement using Converging Boundary Layer Suction Slots

    OpenAIRE

    K. Vasudeva Karanth; N. Yagnesh Sharma

    2009-01-01

    Generally flow behavior in centrifugal fan is observed to be in a state of instability with flow separation zones on suction surface as well as near the front shroud. Overall performance of the diffusion process in a centrifugal fan could be enhanced by judiciously introducing the boundary layer suction slots. With easy accessibility of CFD as an analytical tool, an extensive numerical whole field analysis of the effect of boundary layer suction slots in discrete regions ...

  1. MR imaging of the major nerves about the elbow: cadaveric study examining the effect of flexion and extension of the elbow and pronation and supination of the forearm

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Sook; Yeh, Lee Ren; Trudell, D.; Resnick, D. [Department of Radiology (114), Veterans Administration Medical Center, San Diego, CA (United States)

    1998-08-01

    Magnetic resonance (MR) imaging provides useful information in the evaluation of peripheral nerves. Recent advances in MR imaging allow for detailed depiction of the soft tissue structures of the elbow joint. Three major nerves are present about the elbow. Six cadaveric elbows were imaged to depict the normal anatomy of these nerves and to determine the best plane and position of the elbow for optimal visualization of each nerve. Axial images of the elbow in full extension with the forearm in supination allow identification of all major nerves. Axial images with the elbow in full flexion allow accurate assessment of the cubital tunnel and the ulner nerve. Axial images of the elbow in full extension with the forearm in pronation are helpful for assessment of the median and radial nerves in the forearm. (orig.) With 11 figs., 20 refs.

  2. MR imaging of the major nerves about the elbow: cadaveric study examining the effect of flexion and extension of the elbow and pronation and supination of the forearm

    International Nuclear Information System (INIS)

    Kim, Young Sook; Yeh, Lee Ren; Trudell, D.; Resnick, D.

    1998-01-01

    Magnetic resonance (MR) imaging provides useful information in the evaluation of peripheral nerves. Recent advances in MR imaging allow for detailed depiction of the soft tissue structures of the elbow joint. Three major nerves are present about the elbow. Six cadaveric elbows were imaged to depict the normal anatomy of these nerves and to determine the best plane and position of the elbow for optimal visualization of each nerve. Axial images of the elbow in full extension with the forearm in supination allow identification of all major nerves. Axial images with the elbow in full flexion allow accurate assessment of the cubital tunnel and the ulner nerve. Axial images of the elbow in full extension with the forearm in pronation are helpful for assessment of the median and radial nerves in the forearm. (orig.)

  3. Incarcerated medial epicondyle fracture following pediatric elbow dislocation: 11 cases.

    Science.gov (United States)

    Dodds, Seth D; Flanagin, Brody A; Bohl, Daniel D; DeLuca, Peter A; Smith, Brian G

    2014-09-01

    To describe outcomes after surgical management of pediatric elbow dislocation with incarceration of the medial epicondyle. We conducted a retrospective case review of 11 consecutive children and adolescents with an incarcerated medial epicondyle fracture after elbow dislocation. All patients underwent open reduction internal fixation using a similar technique. We characterized outcomes at final follow-up. Average follow-up was 14 months (range, 4-56 mo). All patients had clinical and radiographic signs of healing at final follow-up. There was no radiographic evidence of loss of reduction at intervals or at final follow-up. There were no cases of residual deformity or valgus instability. Average final arc of elbow motion was 4° to 140°. All patients had forearm rotation from 90° supination to 90° pronation. Average Mayo elbow score was 99.5. Four of 11 patients had ulnar nerve symptoms postoperatively and 1 required a second operation for ulnar nerve symptoms. In addition, 1 required a second operation for flexion contracture release with excision of heterotopic ossification. Three patients had ulnar nerve symptoms at final follow-up. Two of these had mild paresthesia only and 1 had both mild paresthesia and weakness. Our results suggest that open reduction internal fixation of incarcerated medial epicondyle fractures after elbow dislocation leads to satisfactory motion and function; however, the injury carries a high risk for complications, particularly ulnar neuropathy. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Pulled elbow in infancy: diagnostic role of imaging

    International Nuclear Information System (INIS)

    Scapinelli, Raffaele; Borgo, Andrea

    2005-01-01

    Purpose. Pulled elbow is a common injury in infancy. Typically the child, after a sudden pull, refuses to use the arm. The history and clinical findings are sufficient to make the diagnosis, and radiography or ultrasonography are not necessary. When imaging procedures are performed, a few small signs are useful to confirm the diagnosis of pulled elbow. Materials and methods. The authors reviewed the radiographic and ultrasonographic signs reported to be suggestive of pulled elbow (increased radio-condylar distance, increased radio-coronoid distance, proximal radio-ulnar diastasis, deviation of the radio-condylar line) and attempted to confirm their presence in children affected by this trauma. Results. Increased radio-condylar and radio-coronoid distance were present in 8 of 8 cases: proximal radio-ulnar diastasis and deviation of the radio-condylar line were inconsistently present. Ultrasonography gave contradictory results. Conclusions. In typical cases of pulled elbow, radiography or ultrasonography are not necessary for diagnosis and treatment. imaging procedures are recommended only in the case of non typical history, in the presence of deformity or traumatic skin lesions and in children over six years of age. Increased radio-coronoid distance on the affected side is the most frequent and visible sign, which can confirm the diagnosis of pulled elbow. Increased radio-condylar distance is also present, but it is not easy to visualize. Proximal radio-ulnar diastasis and deviation of the radio-condylar line are inconstant. Ultrasonography is difficult to standardize [it

  5. The posterior transtriceps approach for elbow arthrography: a forgotten technique?

    International Nuclear Information System (INIS)

    Lohman, M.; Borrero, C.; Casagranda, B.; Rafiee, B.; Towers, J.

    2009-01-01

    To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures. (orig.)

  6. Pipe drafting and design

    CERN Document Server

    Parisher, Roy A

    2011-01-01

    Pipe Drafting and Design, Third Edition provides step-by-step instructions to walk pipe designers, drafters, and students through the creation of piping arrangement and isometric drawings. It includes instructions for the proper drawing of symbols for fittings, flanges, valves, and mechanical equipment. More than 350 illustrations and photographs provide examples and visual instructions. A unique feature is the systematic arrangement of drawings that begins with the layout of the structural foundations of a facility and continues through to the development of a 3-D model. Advanced chapters

  7. Validation of nonlinear FEA models of a thin-walled elbow under extreme loading conditions for Sodium-cooled Fast Reactors

    International Nuclear Information System (INIS)

    Watakabe, Tomoyoshi; Wakai, Takashi; Jin, Chuanrong; Usui, Yoshiya; Sakai, Shinkichi; Ooshika, Junji; Tsukimori, Kazuyuki

    2015-01-01

    For the purpose of confirming failure modes and safety margin, some studies on the ultimate strength of thin-walled piping components for Sodium-cooled Fast Reactors (SFRs) under extreme loading conditions such as large earthquakes have been reported these several years. Nonlinear finite element analysis has been applied in these studies to simulate buckling and yielding with large deformation, whose accuracy is dependent on the element type, the mesh size, the elasto-plastic model and so on. It is important to check the validation of a finite element model for nonlinear analysis especially under extreme loading conditions. This paper presents static and dynamic analyses of a thin-walled elbow with large deformation under large seismic loading, and discusses the validation of the FEA models comparing with experimental results. The finite element analysis models in this study are generated by shell elements for a stainless steel pipe elbow of diameter-to-thickness ratio 59:1 similar to the main pipe of SFRs, which is used for shaking table tests. At first, a static analysis is carried out for an in-plane monotonic bending test, in order to confirm that the shell element is appropriate to the large deformation analysis and the material parameters are proper for the strain level in the experiments. And then, a dynamic in-plane bending test with the maximum acceleration of 11.7G is simulated by the nonlinear FEA with stiffness-proportional damping. The influence of mesh sizes on results is investigated, to determine proper mesh sizes and reduce the computational cost. Finally, comparing the results of the FEM analyses with those of experiments, it is concluded that the appropriately generated FEA models are effective and give accurate results for nonlinear analyses of the thin-walled elbow under large seismic loading. (author)

  8. Installation process of suction anchors in Gulf of Guinea clay : Centrifuge modelling

    OpenAIRE

    THOREL, Luc; GARNIER, Jacques; RAULT, Gérard; DENDANI, Hédi; COLLIAT, JL

    2010-01-01

    The preparation process of a deepwater Gulf of Guinea clay for modelling of 24 m long suction anchors at a scale of 1/100 in the LCPC centrifuge, the clay characteristics and the installation phase (self-weight and suction) are presented. Two types of caissons have been tested in each tub : one with stiffeners and the other without stiffener. The embedment ratio is close to the suction caisson's slenderness of 3. An analysis of the forces of suction and soil friction shows, as expected, hi...

  9. Numerical Buckling Analysis of Large Suction Caissons for Wind Turbines on Deep Water

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming cost-effective technology also referred to as bucket foundations. During operation, the monopod bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation...... the suction caisson is loaded by external pressure (internal suction) due to evacuation of water inside the bucket and vertical forces due to gravity. The risk of structural buckling during installation of large-diameter suction caissons is addressed using numerical methods. Initial imperfect geometries...

  10. Heat pipe development

    Science.gov (United States)

    Bienart, W. B.

    1973-01-01

    The objective of this program was to investigate analytically and experimentally the performance of heat pipes with composite wicks--specifically, those having pedestal arteries and screwthread circumferential grooves. An analytical model was developed to describe the effects of screwthreads and screen secondary wicks on the transport capability of the artery. The model describes the hydrodynamics of the circumferential flow in triangular grooves with azimuthally varying capillary menisci and liquid cross-sections. Normalized results were obtained which give the influence of evaporator heat flux on the axial heat transport capability of the arterial wick. In order to evaluate the priming behavior of composite wicks under actual load conditions, an 'inverted' glass heat pipe was designed and constructed. The results obtained from the analysis and from the tests with the glass heat pipe were applied to the OAO-C Level 5 heat pipe, and an improved correlation between predicted and measured evaporator and transport performance were obtained.

  11. Myositis ossificans traumatica causing ankylosis of the elbow.

    Science.gov (United States)

    Kanthimathi, B; Udhaya Shankar, S; Arun Kumar, K; Narayanan, V L

    2014-12-01

    Myositis ossificans traumatica is an unusual complication following a muscle contusion injury. A significantly large myositic mass causing ankylosis of the elbow is even rarer. We report a 13-year-old boy who presented with a 14-month history of a fixed elbow with no movement and a palpable bony mass in the anterior aspect of the elbow. He had sustained significant trauma to the affected limb 1 month prior to onset of symptoms, which was managed by native massage and bandaging for 4 weeks. The clinicoradiological diagnosis was suggestive of myositis ossificans, and the myositic mass was completely excised. Histopathology revealed lamellar bone. The 2-year follow-up showed full function of the affected limb and no signs of recurrence. We report this case of clinical interest due to the unusually large myositic mass.

  12. The Unilateral Below Elbow Test: a function test for children with unilateral congenital below elbow deficiency.

    Science.gov (United States)

    Bagley, Anita M; Molitor, Fred; Wagner, Lisa V; Tomhave, Wendy; James, Michelle A

    2006-07-01

    The Unilateral Below Elbow Test (UBET) was developed to evaluate function in bimanual activities for both the prosthesis wearer and non-wearer. Nine tasks were chosen for each of four age-specific categories defined by development stages of hand function (2-4y, 5-7y, 8-10y, and 11-21y). Two scales, Completion of Task and Method of Use, were designed to rate performance. To measure reliability, four occupational therapists scored samples of videotaped UBET performances. For Completion of Task, an interval scale, agreement in scoring was measured with interclass correlation coefficients (ICC; n=9; five females, four males). For Method of Use, a nominal scale, chance-adjusted association was calculated with Cohen's kappa coefficients (interobserver n=198; 111 females, 87 males; intraobserver n=93; 56 females, 37 males). For Completion of Task, the average ICC was 0.87 for the prosthesis-on condition, and 0.85 for the prosthesis-off condition. ICCs exceeded 0.80 for eight out of nine tasks for the two older age groups, but for only five out of nine tasks in the younger age groups. Higher inter- and intraobserver kappa coefficients for Method of Use resulted when scoring children with their prostheses on versus off. The oldest age group had lower kappa values than the other three groups. The UBET is recommended for the functional evaluation of Completion of Task in children with unilateral congenital below elbow deficiency with and without their prostheses. Method of Use scoring can evaluate individuals for directed therapy interventions or prosthetic training.

  13. Simplified pipe gun

    International Nuclear Information System (INIS)

    Sorensen, H.; Nordskov, A.; Sass, B.; Visler, T.

    1987-01-01

    A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of +- 2% are obtained with a propellant gas pressure of 40 bar

  14. Stuck pipe prediction

    KAUST Repository

    Alzahrani, Majed

    2016-03-10

    Disclosed are various embodiments for a prediction application to predict a stuck pipe. A linear regression model is generated from hook load readings at corresponding bit depths. A current hook load reading at a current bit depth is compared with a normal hook load reading from the linear regression model. A current hook load greater than a normal hook load for a given bit depth indicates the likelihood of a stuck pipe.

  15. Stuck pipe prediction

    KAUST Repository

    Alzahrani, Majed; Alsolami, Fawaz; Chikalov, Igor; Algharbi, Salem; Aboudi, Faisal; Khudiri, Musab

    2016-01-01

    Disclosed are various embodiments for a prediction application to predict a stuck pipe. A linear regression model is generated from hook load readings at corresponding bit depths. A current hook load reading at a current bit depth is compared with a normal hook load reading from the linear regression model. A current hook load greater than a normal hook load for a given bit depth indicates the likelihood of a stuck pipe.

  16. Dynamic stiffness of suction caissons - torsion, sliding and rocking

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the skirt length and the Poisson's ratio of the subsoil. Finally, the high-frequency impedance has been determined for future use in lumped-parameter models of wind turbine foundations in aero-elastic codes. (au)

  17. The impact of soil suction variation on earthquake intensity indices

    Directory of Open Access Journals (Sweden)

    Biglari Mahnoosh

    2016-01-01

    Full Text Available Soil properties can completely change the ground motion characteristics as they travel from the bedrock to the surface because, soil as a low-pass filter, may amplify or deamplify seismic motions in some frequencies on the wave travelling path. Recent studies about the advanced unsaturated soil mechanics clearly shows that dynamic properties of soils, including small-strain shear modulus (Gmax, shear modulus reduction (G/Gmax, and damping ratio (D curves are affected by changes in the soil suction level. The current study present nonlinear time-dependent analysis of three different unsaturated soils available in the literature with different ranges of nonlinear behaviour that earlier have been studied on unsaturated dynamic models. Since, the earthquake intensity parameters can be used to describe the damage potential of an earthquake, the focus of this paper is to evaluate the impact of the suction variation on the engineering ground motion parameters, including peak values of strong motion, Vmax/Amax, root-mean-square acceleration, Arias intensity, characteristic intensity, cumulative absolute velocity, acceleration spectrum intensity, effective design acceleration, A95 parameter and predominant period separately under the near-field and the far-field seismicity categories.

  18. Temperature measurement in WTE boilers using suction pyrometers.

    Science.gov (United States)

    Rinaldi, Fabio; Najafi, Behzad

    2013-11-15

    The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE) plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR) pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  19. Kinematics of suction feeding in the seahorse Hippocampus reidi.

    Science.gov (United States)

    Roos, Gert; Van Wassenbergh, Sam; Herrel, Anthony; Aerts, Peter

    2009-11-01

    Fish typically use a rostro-caudal wave of head expansion to generate suction, which is assumed to cause a uni-directional, anterior-to-posterior flow of water in the expanding head. However, compared with typical fish, syngnathid fishes have a remarkably different morphology (elongated snout, small hyoid, immobile pectoral girdle) and feeding strategy (pivot feeding: bringing the small mouth rapidly close to the prey by neurocranial dorsorotation). As a result, it is unclear how suction is generated in Syngnathidae. In this study, lateral and ventral expansions of the head were quantified in Hippocampus reidi and linked to the kinematics of the mouth, hyoid and neurocranium. In addition, the flow velocities inside the bucco-pharyngeal cavity and in front of the mouth were calculated. Our data suggest that the volume changes caused by lateral expansion are dominant over ventral expansion. Maximum gape, neurocranium rotation and hyoid depression are all reached before actual volume increase and before visible prey movement. This implies that, unlike previously studied teleosts, hyoid rotation does not contribute to ventral expansion by lowering the floor of the mouth during prey capture in H. reidi. The lateral volume changes show a rostro-caudal expansion, but the maximal flow velocity is not near the mouth aperture (as has been demonstrated for example in catfish) but at the narrow region of the buccal cavity, dorsal to the hyoid.

  20. Temperature Measurement in WTE Boilers Using Suction Pyrometers

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2013-11-01

    Full Text Available The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  1. Heat pipe dynamic behavior

    Science.gov (United States)

    Issacci, F.; Roche, G. L.; Klein, D. B.; Catton, I.

    1988-01-01

    The vapor flow in a heat pipe was mathematically modeled and the equations governing the transient behavior of the core were solved numerically. The modeled vapor flow is transient, axisymmetric (or two-dimensional) compressible viscous flow in a closed chamber. The two methods of solution are described. The more promising method failed (a mixed Galerkin finite difference method) whereas a more common finite difference method was successful. Preliminary results are presented showing that multi-dimensional flows need to be treated. A model of the liquid phase of a high temperature heat pipe was developed. The model is intended to be coupled to a vapor phase model for the complete solution of the heat pipe problem. The mathematical equations are formulated consistent with physical processes while allowing a computationally efficient solution. The model simulates time dependent characteristics of concern to the liquid phase including input phase change, output heat fluxes, liquid temperatures, container temperatures, liquid velocities, and liquid pressure. Preliminary results were obtained for two heat pipe startup cases. The heat pipe studied used lithium as the working fluid and an annular wick configuration. Recommendations for implementation based on the results obtained are presented. Experimental studies were initiated using a rectangular heat pipe. Both twin beam laser holography and laser Doppler anemometry were investigated. Preliminary experiments were completed and results are reported.

  2. Replaceable liquid nitrogen piping

    International Nuclear Information System (INIS)

    Yasujima, Yasuo; Sato, Kiyoshi; Sato, Masataka; Hongo, Toshio

    1982-01-01

    This liquid nitrogen piping with total length of about 50 m was made and installed to supply the liquid nitrogen for heat insulating shield to three superconducting magnets for deflection and large super-conducting magnet for detection in the π-meson beam line used for high energy physics experiment in the National Laboratory for High Energy Physics. The points considered in the design and manufacture stages are reported. In order to minimize the consumption of liquid nitrogen during transport, vacuum heat insulation method was adopted. The construction period and cost were reduced by the standardization of the components, the improvement of welding works and the elimination of ineffective works. For simplifying the maintenance, spare parts are always prepared. The construction and the procedure of assembling of the liquid nitrogen piping are described. The piping is of double-walled construction, and its low temperature part was made of SUS 316L. The super-insulation by aluminum vacuum evaporation and active carbon were attached on the external surface of the internal pipe. The final leak test and the heating degassing were performed. The tests on evacuation, transport capacity and heat entry are reported. By making the internal pipe into smaller size, the piping may be more efficient. (Kako, I.)

  3. Static progressive versus dynamic splinting for posttraumatic elbow stiffness: a systematic review of 232 patients

    NARCIS (Netherlands)

    Veltman, Ewout S.; Doornberg, Job N.; Eygendaal, Denise; van den Bekerom, Michel P. J.

    2015-01-01

    The elbow is prone to stiffness after trauma. To regain functional elbow motion, several conservative and surgical treatment options are available. Nonoperative treatment includes physical therapy, intra-articular injections with corticosteroids, and a static progressive or dynamic splinting

  4. Romantic Resonances in the Rhetoric of Peter Elbow's "Writing Without Teachers."

    Science.gov (United States)

    Yager, Kristi

    1996-01-01

    Seeks to uncover the historical roots within English Romanticism of Peter Elbow's thinking in order to show the depth and complexity of his assumptions about writing. Implicitly refutes charges questioning the intellectual credibility of Elbow's work. (TB)

  5. 78 FR 68907 - Agency Information Collection (Elbow and Forearm Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-11-15

    ... Forearm Conditions Disability Benefits Questionnaire) Under OMB Review AGENCY: Veterans Benefits... Control No. 2900- NEW (Elbow and Forearm Conditions Disability Benefits Questionnaire)'' in any... Benefits Questionnaire)''. SUPPLEMENTARY INFORMATION: Title: Elbow and Forearm Conditions Disability...

  6. Measurement issues in the sonographic assessment of tennis elbow.

    Science.gov (United States)

    Poltawski, Leon; Jayaram, Vijay; Watson, Tim

    2010-05-01

    Sonography is increasingly being used for assessment in tennis elbow research and clinical practice, but there are a lack of data regarding its validity, reliability, and responsiveness to change for this application. Studies using the modality were reviewed to establish current levels of evidence for these measurement properties. There is reasonable evidence regarding its validity for identifying tennis elbow tendinopathy, but a lack of data addressing its reliability and responsiveness. Practical issues affecting image quality are discussed, and recommendations for further investigation are suggested, to enhance the credible use of sonography with this debilitating condition.

  7. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  8. Clinical application of advances in elbow and forearm anatomy and biomechanics.

    Science.gov (United States)

    Zimmerman, Neal B

    2002-02-01

    The static and dynamic stabilizers of the elbow and forearm axis are closely interrelated in elbow and forearm unit motion and load handling. An [figure: see text] understanding of elbow and forearm anatomy is crucial to the surgeon evaluating and treating complex pathologies resulting from acute or remote trauma.

  9. Incidence and risk factors for the development of radiographic arthrosis after traumatic elbow injuries

    NARCIS (Netherlands)

    Guitton, Thierry G.; Zurakowski, David; van Dijk, Niek C.; Ring, David

    2010-01-01

    Radiographic arthrosis is a common sequela of elbow trauma. Few studies have addressed risk factors for radiographic arthrosis after elbow injury, especially in the long term. Data from multiple long-term follow-up studies of patients with surgically treated elbow fractures provided us with an

  10. Qualification of a Method to Calculate the Irrecoverable Pressure Loss in High Reynolds Number Piping Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sigg, K. C.; Coffield, R. D.

    2002-09-01

    High Reynolds number test data has recently been reported for both single and multiple piping elbow design configurations at earlier ASME Fluid Engineering Division conferences. The data of these studies ranged up to a Reynolds number of 42 x 10[sup]6 which is significantly greater than that used to establish design correlations before the data was available. Many of the accepted design correlations, based on the lower Reynolds number data, date back as much as fifty years. The new data shows that these earlier correlations are extremely conservative for high Reynolds number applications. Based on the recent high Reynolds number information a new recommended method has been developed for calculating irrecoverable pressure loses in piping systems for design considerations such as establishing pump sizing requirements. This paper describes the recommended design approach and additional testing that has been performed as part of the qualification of the method. This qualification testing determined the irrecoverable pressure loss of a piping configuration that would typify a limiting piping section in a complicated piping network, i.e., multiple, tightly coupled, out-of-plane elbows in series under high Reynolds number flow conditions. The overall pressure loss measurements were then compared to predictions, which used the new methodology to assure that conservative estimates for the pressure loss (of the type used for pump sizing) were obtained. The recommended design methodology, the qualification testing and the comparison between the predictions and the test data are presented. A major conclusion of this study is that the recommended method for calculating irrecoverable pressure loss in piping systems is conservative yet significantly lower than predicted by early design correlations that were based on the extrapolation of low Reynolds number test data.

  11. Effects of suction-dredging for cockles on non-target fauna in the Wadden Sea

    NARCIS (Netherlands)

    Hiddink, JG

    2003-01-01

    Suction dredging for cockles removes large cockles from tidal flats and may also cause mortality of non-target fauna and make the habitat less suitable for some species. This study examines whether suction dredging for cockles on tidal flats of the Dutch Wadden Sea had affected densities of

  12. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Science.gov (United States)

    2010-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  13. Development of advanced stability theory suction prediction techniques for laminar flow control. [on swept wings

    Science.gov (United States)

    Srokowski, A. J.

    1978-01-01

    The problem of obtaining accurate estimates of suction requirements on swept laminar flow control wings was discussed. A fast accurate computer code developed to predict suction requirements by integrating disturbance amplification rates was described. Assumptions and approximations used in the present computer code are examined in light of flow conditions on the swept wing which may limit their validity.

  14. A Technique for Controlling Matric Suction on Filter Papers . GroWth ...

    African Journals Online (AJOL)

    'Abstract. Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers ...

  15. A Technique for Controlling Matric Suction on Filter Papers Used in ...

    African Journals Online (AJOL)

    Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers wetted to ...

  16. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Ye, W.M., E-mail: ye_tju@tongji.edu.cn [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); United Research Center for Urban Environment and Sustainable Development, The Ministry of Education, Shanghai 200092 (China); Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Cui, Y.J. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Ecole des Ponts ParisTech, UR Navier/CERMES 77455 (France)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Heating induced volumetric change of GMZ01 bentonite depends on suction. Black-Right-Pointing-Pointer Suction has significant influence on compressibility. Black-Right-Pointing-Pointer Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 Degree-Sign C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 Multiplication-Sign 10{sup -4} Degree-Sign C{sup -1}; (2) with increasing suction, the elastic compressibility {kappa} and the plastic compressibility {lambda}(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility {lambda}(s) slightly decreases and the yield surface tends to shrink.

  17. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    International Nuclear Information System (INIS)

    Ye, W.M.; Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G.; Cui, Y.J.

    2012-01-01

    Highlights: ► Heating induced volumetric change of GMZ01 bentonite depends on suction. ► Suction has significant influence on compressibility. ► Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 °C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 × 10 −4 °C −1 ; (2) with increasing suction, the elastic compressibility κ and the plastic compressibility λ(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility λ(s) slightly decreases and the yield surface tends to shrink.

  18. 78 FR 20316 - Final Issuance of General NPDES Permits (GP) for Small Suction Dredges in Idaho

    Science.gov (United States)

    2013-04-04

    ... System (NPDES) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction... Small Suction Dredges in Idaho AGENCY: Environmental Protection Agency, Region 10. ACTION: Final notice... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  19. A Report on Deliverable Three: Determine a Standard Performance Test for Military Suction Device Use

    Science.gov (United States)

    2017-09-20

    evaluating device suction while either wetted or completely immersed is highly important to predict performance in battlefield scenarios. Summary...mechanical, electrical, and environmental. OBJECTIVE: Research and review current test methods outlined in ISO 10079 and published journal articles...of contemporary oropharyngeal suction. The American journal of emergency medicine 17, 611- 613 (1999). 4. Hodgetts, T., Mahoney, P., Evans, G

  20. Numerical simulation and experimental investigation on suction heating of a BOG compressor

    International Nuclear Information System (INIS)

    Jia, Xiaohan; Zhao, Bin; Feng, Jianmei; Zheng, Sulu; Peng, Xueyuan

    2016-01-01

    Highlights: • An investigation focusing on suction heating of a BOG compressor is carried out. • There is frost on the cylinder cover as the compressor at lower suction temperature. • The suction and discharge flow rate decrease with rising suction temperature. • The volumetric efficiency has a maximum value with increasing suction temperature. • The temperature coefficient increased with suction temperature or rotational speed. - Abstract: One of the key components of a liquefied natural gas (LNG) receiving terminal is the boil-off gas (BOG) compressor, which is used to pump out the BOG from the LNG storage tank to ensure safety in the transportation and receiving systems. Owing to the ultra-low suction temperature, the heat exchange between the intake gas and the cylinder, piston, and cylinder cover cannot be ignored as in normal conditions. This paper presents an investigation focusing on suction heating of the BOG compressor. A finite element model with dynamic mesh was established to simulate the suction process. At the same time, a performance test rig was built to study the characteristics of the BOG compressor under low suction temperature conditions and verify the numerical model. Consequently, the results of the simulation were in good agreement with experimental results. Both results implied that the temperature of cylinder surface increased starting from the cylinder cover to the crankcase. In addition, at lower suction temperature, the temperature difference between various points on the cylinder surface and cylinder cover was much larger than that at higher suction temperature. With increasing suction temperature, the temperature coefficient increased markedly, and the difference between gas temperatures at the beginning and end of the suction process, as well as the compressor flow rate, decreased significantly; however, the volumetric efficiency increased first and then decreased. Furthermore, the temperature coefficient clearly increased

  1. Metallurgical factors that contribute to cracking in BWR piping

    International Nuclear Information System (INIS)

    Weeks, J.R.

    1975-01-01

    During the fall of 1974 and early winter of 1975, cracks have been discovered in the 4 in. bypass lines of several Boiling Water Reactors (BWR's) in the United States. Further, similar cracks were discovered at two BWR's in Japan during the same period. More recently, cracks have been discovered in the core spray piping and in a furnace-sensitized ''safe end'' and adjacent ''dutchman'' at the Dresden Nuclear Power Station, Unit No. 2. Although inspections at all other U.S. BWR's have not disclosed further instances of cracking in core spray piping, leaking cracks have been found in the core spray piping of two BWR's overseas. Metallurgical examinations of these cracks are not yet complete. The following observations have been made to date. All cracks (except those in the furnace-sensitized safe end and dutchman) occurred in seamless type 304 stainless steel piping or in elbows fabricated from such piping, in the outer heat affected zone of either field or shop welds, in lines isolated from the main primary coolant flow during full power operation, except for the not yet examined cracks in the Monticello bypass lines. The cracks are exclusively intergranular, and occur in metal that has been lightly sensitized by the welding process, with only intermittent grain boundary carbides. They developed in the areas of peak axial residual stresses from welding rather than in the most heavily sensitized areas. No fatigue striations have been found on the fracture surfaces. The evidence received to date strongly indicates that these cracks were caused by intergranular stress corrosion of weld-sensitized stainless steel by BWR water containing greater than 0.2 ppM oxygen. The possible role of fatigue or alternating stresses in this corrosion is not clear. Further, not all the cracks detected to date necessarily have occurred by the same mechanism

  2. Peach Bottom Atomic Power Station recirc pipe dose rates with zinc injection and condenser replacement

    International Nuclear Information System (INIS)

    DiCello, D.C.; Odell, A.D.; Jackson, T.J.

    1995-01-01

    Peach Bottom Atomic Power Station (PBAPS) is located near the town of Delta, Pennsylvania, on the west bank of the Susquehanna River. It is situated approximately 20 miles south of Lancaster, Pennsylvania. The site contains two boiling water reactors of General Electric design and each rated at 3,293 megawatts thermal. The units are BWR 4s and went commercial in 1977. There is also a decommissioned high temperature gas-cooled reactor on site, Unit 1. PBAPS Unit 2 recirc pipe was replaced in 1985 and Unit 3 recirc pipes replaced in 1988 with 326 NGSS. The Unit 2 replacement pipe was electropolished, and the Unit 3 pipe was electropolished and passivated. The Unit 2 brass condenser was replaced with a Titanium condenser in the first quarter of 1991, and the Unit 3 condenser was replaced in the fourth quarter of 1991. The admiralty brass condensers were the source of natural zinc in both units. Zinc injection was initiated in Unit 2 in May 1991, and in Unit 3 in May 1992. Contact dose rate measurements were made in standard locations on the 28-inch recirc suction and discharge lines to determine the effectiveness of zinc injection and to monitor radiation build-up in the pipe. Additionally, HPGe gamma scans were performed to determine the isotopic composition of the oxide layer inside the pipe. In particular, the specific (μCi/cm 2 ) of Co-60 and Zn-65 were analyzed

  3. Modification of large-scale motions in a turbulent pipe flow

    Science.gov (United States)

    Senshu, Kohei; Shinozaki, Hiroaki; Sakakibara, Jun

    2017-11-01

    We performed experiments to modify the flow structures in a fully developed turbulent flow in a straight round pipe. The modification of the flow was achieved by installing a short coaxial inner pipe. The inner pipe has ability to add continuous suction or blowing disturbance through its outer surface. The experiments were conducted at a Reynolds number of 44,000 with seven different disturbance patterns. The wall static pressure was measured and pipe friction coefficient was evaluated. The velocity distribution was measured with PIV and very large scale motions (VLSMs) were visualized. Pipe friction coefficient was increased by installing the inner pipe, while turbulence intensities over the cross section were reduced. Slight change of the friction was observed if the disturbance was added. We decomposed fluctuating velocity field in the azimuthal direction by a Fourier series expansion. As a result, we obtained that contribution of lower azimuthal mode numbers (m = 2, 3, 4) reduced while the higher modes increased. This was consistent with the observation of visualized very large scale motions.

  4. Peach Bottom Atomic Power Station recirc pipe dose rates with zinc injection and condenser replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiCello, D.C.; Odell, A.D.; Jackson, T.J. [PECO Energy Co., Delta, PA (United States)

    1995-03-01

    Peach Bottom Atomic Power Station (PBAPS) is located near the town of Delta, Pennsylvania, on the west bank of the Susquehanna River. It is situated approximately 20 miles south of Lancaster, Pennsylvania. The site contains two boiling water reactors of General Electric design and each rated at 3,293 megawatts thermal. The units are BWR 4s and went commercial in 1977. There is also a decommissioned high temperature gas-cooled reactor on site, Unit 1. PBAPS Unit 2 recirc pipe was replaced in 1985 and Unit 3 recirc pipes replaced in 1988 with 326 NGSS. The Unit 2 replacement pipe was electropolished, and the Unit 3 pipe was electropolished and passivated. The Unit 2 brass condenser was replaced with a Titanium condenser in the first quarter of 1991, and the Unit 3 condenser was replaced in the fourth quarter of 1991. The admiralty brass condensers were the source of natural zinc in both units. Zinc injection was initiated in Unit 2 in May 1991, and in Unit 3 in May 1992. Contact dose rate measurements were made in standard locations on the 28-inch recirc suction and discharge lines to determine the effectiveness of zinc injection and to monitor radiation build-up in the pipe. Additionally, HPGe gamma scans were performed to determine the isotopic composition of the oxide layer inside the pipe. In particular, the specific ({mu}Ci/cm{sup 2}) of Co-60 and Zn-65 were analyzed.

  5. A leak-before-break strategy for CANDU primary piping systems

    International Nuclear Information System (INIS)

    Aggarwal, M.L.; Kozluk, M.J.; Lin, T.C.; Manning, B.W.; Vijay, D.K.

    1986-01-01

    Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the United States and the Federal Republic of Germany) was carried out. The approach presented makes use of recent American developments in the area of elastic-plastic fracture mechanics. It also gives consideration to aspects which are unique to the pressurized heavy water (CANDU) reactors used by Ontario Hydro. The proposed leak-before-break approach is described and its use is illustrated by applying it to the Darlington generating station primary heat transport system pump suction piping. (author)

  6. Cavitation simulation and NPSH prediction of a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Li, P; Huang, Y F; Li, J

    2012-01-01

    This paper illustrates the flow field numerical analysis of the double-suction centrifugal pump. For the study of the cavitation flow inside the double-suction centrifugal pump, the professional pump/motor simulation software PumpLinx and its Full Cavitation Model has been employed. According to the PumpLinx calculation result and the Cavitation damage index, the cavitation position, level and the cavitation characteristics of the double-suction centrifugal pump has been predicted. For the further objective, the simulation of the flow field in the double-suction centrifugal pump under different inlet conditions has been carried out. By the result analysis, NPSHr has been predicted; the reliability of the results has been verified by comparing with the experimental data. At the same time, this practice can provide guidance for the optimal design of double-suction pump.

  7. Effect of suction on the mechanical characteristics of uniformly compacted rammed earth

    Science.gov (United States)

    El Hajjar, A.; Chauhan, P.; Prime, N.; Plé, O.

    2018-04-01

    Rammed earth, in the current environmental situation, is an alternative construction technique which can help in reducing energy and raw material consumption owing to its “sustainable” characteristics. To fully understand its behavior and properties, recent scientific investigations consider it as a compacted unsaturated material with suction as its one of the main sources of strength. Eathern constructions face, over their lifetime, variations in the suction state which have a significant impact on their mechanical characteristics. In the present contribution, unconfined compression tests are performed, with and without unload-reload cycles, on homogeneously compacted samples subjected to various suction conditions. This study shows that both the unconfined compressive strength and Young modulus reduce with the reduction of suction states. Suction also seems to influence the amount of plastic strains and damage phenomenon. Indeed, the soils analyzed are slightly active and shows both plasticity behavior and damage phenomenon.

  8. Rehabilitation of the Overhead Athlete’s Elbow

    Science.gov (United States)

    Wilk, Kevin E.; Macrina, Leonard C.; Cain, E. Lyle; Dugas, Jeffrey R.; Andrews, James R.

    2012-01-01

    The activities required during overhead sports, particularly during baseball pitching, produce large forces at the elbow joint. Injuries to the elbow joint frequently occur in the overhead athlete because of the large amount of forces observed during the act of throwing, playing tennis, or playing golf. Injuries may result because of repetitive overuse, leading to tissue failure. Rehabilitation following injury or surgery to the throwing elbow is vital to fully restore normal function and return the athlete to competition as quickly and safely as possible. Rehabilitation of the elbow, whether following injury or postsurgical, must follow a progressive and sequential order, building on the previous phase, to ensure that healing tissues are not compromised. Emphasis is placed on restoring full motion, muscular strength, and neuromuscular control while gradually applying loads to healing tissue. In addition, when one is creating a rehabilitation plan for athletes, it is imperative to treat the entire upper extremity, core, and legs to create and dissipate the forces generated at each joint. PMID:23016113

  9. A review of national shoulder and elbow joint replacement registries

    DEFF Research Database (Denmark)

    Rasmussen, Jeppe V; Olsen, Bo S; Fevang, Bjørg-Tilde S

    2012-01-01

    The aim was to review the funding, organization, data handling, outcome measurements, and findings from existing national shoulder and elbow joint replacement registries; to consider the possibility of pooling data between registries; and to consider wether a pan european registry might be feasible....

  10. The role of total elbow arthroplasty in traumatology.

    Science.gov (United States)

    Mansat, P; Bonnevialle, N; Rongières, M; Bonnevialle, P

    2014-10-01

    Fractures of the distal humerus account for 5% of osteoporotic fractures in subjects older than 60 years. A history of osteoporosis, co-morbidities, and joint comminution make their management difficult. The therapeutic options are limited to functional treatments, osteosynthesis, or either partial or total arthroplasty. Functional treatment of distal humerus fractures in the elderly subject provide inconsistent results, often with persistence of pain with a stiff or unstable elbow. Osteosynthesis remains the reference treatment for these fractures, following the principle of stable and rigid osteosynthesis allowing early mobilization. However, joint comminution and a history of osteoporosis occasionally make it impossible to meet this objective, with a considerable rate of complications and surgical revisions. Total elbow arthroplasty remains an alternative to osteosynthesis with very satisfactory immediate results restoring a painless, stable, and functional elbow. These results seem reproducible and sustainable over time. The complication rate is not uncommon with an approximately 10% surgical revision rate. Elbow hemiarthroplasty remains to be validated in this indication. V. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. Elbow joint stability following experimental osteoligamentous injury and reconstruction

    DEFF Research Database (Denmark)

    Deutch, Søren R; Jensen, Steen Lund; Tyrdal, Stein

    2003-01-01

    Elbow joint dislocation was simulated in cadaveric specimens to quantify laxity induced by radial head and coronoid process lesions, either alone or in combination with collateral ligament insufficiency. The effects of lateral ligament reconstruction and radial head prosthesis replacement were also...

  12. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  13. Static Progressive Orthoses for Elbow Contracture: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Bin Chen

    2017-01-01

    Full Text Available Background. As one of the most common musculoskeletal complications following trauma, elbow contracture is a frequent source of disabled daily activities. Conventional interventions are inadequate to provide favorable outcome. The static progressive orthoses are getting popular in the treatment of this problem. Objective. The purpose of this review was to assess the effectiveness of static progressive orthoses for elbow contracture. Methods. Literatures when written in English published during 1 January 1997 and 31 January 2017 were searched in the following databases: Web of Science, Cochrane Library, PubMed, and EBSCOhost. Articles are quality-assessed by two assessors, each article was summarized in evidence tables, and a narrative synthesis was also performed. Results. Ten clinical trials were included. The study design and outcome measures used varied. Significant immediate improvement in the range of motion was reported by all studies, and those effects were still significant at follow-up. No significant difference was shown between static progressive and dynamic orthoses for elbow contracture in one randomized control trial. Conclusions. Current low-quality evidence suggested that static progressive orthoses provided assistance for elbow contracture through improving range of motion. Further research is recommended using high-quality randomized controlled trials.

  14. Diagnosing ulnar neuropathy at the elbow using magnetic resonance neurography

    Energy Technology Data Exchange (ETDEWEB)

    Keen, Nayela N.; Chin, Cynthia T.; Saloner, David; Steinbach, Lynne S. [University of California San Francisco, Dept of Radiology and Biomedical Imaging, San Francisco, CA (United States); Engstrom, John W. [University of California San Francisco, Department of Neurology, San Francisco, CA (United States)

    2012-04-15

    Early diagnosis of ulnar neuropathy at the elbow is important. Magnetic resonance neurography (MRN) images peripheral nerves. We evaluated the usefulness of elbow MRN in diagnosing ulnar neuropathy at the elbow. The MR neurograms of 21 patients with ulnar neuropathy were reviewed retrospectively. MRN was performed prospectively on 10 normal volunteers. The MR neurograms included axial T1 and axial T2 fat-saturated and/or axial STIR sequences. The sensitivity and specificity of MRN in detecting ulnar neuropathy were determined. The mean ulnar nerve size in the symptomatic and normal groups was 0.12 and 0.06 cm{sup 2} (P < 0.001). The mean relative signal intensity in the symptomatic and normal groups was 2.7 and 1.4 (P < 0.01). When using a size of 0.08 cm{sup 2}, sensitivity was 95% and specificity was 80%. Ulnar nerve size and signal intensity were greater in patients with ulnar neuropathy. MRN is a useful test in evaluating ulnar neuropathy at the elbow. (orig.)

  15. Nontyphoidal Salmonella Septic arthritis of the elbow in a healthy ...

    African Journals Online (AJOL)

    A case of rarely encountered nontyphoidal Salmonella septic arthritis of the elbow in an infant with no preexisting disease is reported. Salmonella etiology was not suspected in this case, and the diagnosis was made only after bacterial isolation. Aspiration of the infected joint with radiological guidance initially failed to give a ...

  16. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  17. Design of triaxial test with controlled suction: measure of strain

    International Nuclear Information System (INIS)

    Gasc-Barbier, M.; Cosenza, Ph.; Ghoreychi, M.; Chanchole, S.; Cosenza, Ph.; Tessier, D.

    2000-01-01

    Experimental study of mechanical behavior of clayey materials under hygrometric condition is usually performed either on unloaded samples or by means of classical odometer tests used in soil mechanics. Such methods are not well adapted to hard deep clayey rocks with little deformability, porosity and permeability. Moreover, stress and strain tensors having a significant effect on hygro-mechanical behaviour and properties cannot be measured and investigated appropriately by classical tests. This is why a specific triaxial test was designed in which the sample is surrounded by a fiber glass tissue allowing air circulation and then by silicon on which confining pressure is applied. Thus, equilibrium between air and sample was reduced. Stress and strain tensors were also measured in time on the sample subjected to a mechanical loading and to a controlled suction. After presentation of the test, preliminary results are given. (authors)

  18. Boundary layer development on turbine airfoil suction surfaces

    Science.gov (United States)

    Sharma, O. P.; Wells, R. A.; Schlinker, R. H.; Bailey, D. A.

    1981-01-01

    The results of a study supported by NASA under the Energy Efficient Engine Program, conducted to investigate the development of boundary layers under the influence of velocity distributions that simulate the suction sides of two state-of-the-art turbine airfoils, are presented. One velocity distribution represented a forward loaded airfoil ('squared-off' design), while the other represented an aft loaded airfoil ('aft loaded' design). These velocity distributions were simulated in a low-speed, high-aspect-ratio wind tunnel specifically designed for boundary layer investigations. It is intended that the detailed data presented in this paper be used to develop improved turbulence model suitable for application to turbine airfoil design.

  19. Modelling of Aquitaine II pipe whipping test with EUROPLEXUS fast dynamics code

    International Nuclear Information System (INIS)

    Potapov, S.

    2003-01-01

    To validate the modelling of multi-physics phenomena with EUROPLEXUS code we considered a pipe whipping problem occurring in thermal hydraulic conditions of a Loss of Coolant Accident in PWR primary circuit. Two numerical fluid-structure interaction (FSI) models, a simplified 'pipe-like' model and a mixed 1D/3D model, were used to simulate both the conditioning phase and a phase of whipping. The results of calculations were compared with existing experimental data. Analysis of numerical results shows that both models give a good prediction of global behaviour of the coupled fluid-structure system, namely for pipe displacements and stresses in the pipe walls, as well as for pressure and velocity in the fluid. By comparison with experimental data, we show that only the mixed EUROPLEXUS model, where the pipe elbow is discretized with shells, allows us to estimate correctly the time history and maximum value of the contact force between the pipe and the obstacle. The 1D model with reduced kinematics (rigid cross section hypothesis) does not allow the correct detection of contact phenomenon. This study shows that the use of mixed numerical models containing simplified and totally 3D parts duly interconnected allows a very efficient and CPU inexpensive numerical analysis which is able to take into account different global and local physical phenomena. (author)

  20. The Second International Piping Integrity Research Group (IPIRG-2) program. Final report, October 1991--April 1996

    International Nuclear Information System (INIS)

    Hopper, A.; Wilowski, G.; Scott, P.; Olson, R.

    1997-03-01

    The IPIRG-2 program was an international group program managed by the US NRC and funded by organizations from 15 nations. The emphasis of the IPIRG-2 program was the development of data to verify fracture analyses for cracked pipes and fittings subjected to dynamic/cyclic load histories typical of seismic events. The scope included: (1) the study of more complex dynamic/cyclic load histories, i.e., multi-frequency, variable amplitude, simulated seismic excitations, than those considered in the IPIRG-1 program, (2) crack sizes more typical of those considered in Leak-Before-Break (LBB) and in-service flaw evaluations, (3) through-wall-cracked pipe experiments which can be used to validate LBB-type fracture analyses, (4) cracks in and around pipe fittings, such as elbows, and (5) laboratory specimen and separate effect pipe experiments to provide better insight into the effects of dynamic and cyclic load histories. Also undertaken were an uncertainty analysis to identify the issues most important for LBB or in-service flaw evaluations, updating computer codes and databases, the development and conduct of a series of round-robin analyses, and analyst's group meetings to provide a forum for nuclear piping experts from around the world to exchange information on the subject of pipe fracture technology. 17 refs., 104 figs., 41 tabs

  1. Incremental-hinge piping analysis methods for inelastic seismic response prediction

    International Nuclear Information System (INIS)

    Jaquay, K.R.; Castle, W.R.; Larson, J.E.

    1989-01-01

    This paper proposes nonlinear seismic response prediction methods for nuclear piping systems based on simplified plastic hinge analyses. The simplified plastic hinge analyses utilize an incremental series of flat response spectrum loadings and replace yielded components with hinge elements when a predefined hinge moment is reached. These hinge moment values, developed by Rodabaugh, result in inelastic energy dissipation of the same magnitude as observed in seismic tests of piping components. Two definitions of design level equivalent loads are employed: one conservatively based on the peaks of the design acceleration response spectra, the other based on inelastic frequencies determined by the method of Krylov and Bogolyuboff recently extended by Lazzeri to piping. Both definitions account for piping system inelastic energy dissipation using Newmark-Hall inelastic response spectrum reduction factors and the displacement ductility results of the incremental-hinge analysis. Two ratchet-fatigue damage models are used: one developed by Rodabaugh that conservatively correlates Markl static fatigue expressions to seismic tests to failure of piping components; the other developed by Severud that uses the ratchet expression of Bree for elbows and Edmunds and Beer for straights, and defines ratchet-fatigue interaction using Coffin's ductility based fatigue equation. Comparisons of predicted behavior versus experimental results are provided for a high-level seismic test of a segment of a representative nuclear plant piping system. (orig.)

  2. Assessment of Pipe Wall Loss Using Guided Wave Testing

    International Nuclear Information System (INIS)

    Joo, Kyung Mun; Jin, Seuk Hong; Moon, Yong Sig

    2010-01-01

    Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion

  3. Combined hyperextension and supination of the elbow joint induces lateral ligament lesions. An experimental study of the pathoanatomy and kinematics in elbow ligament injuries

    DEFF Research Database (Denmark)

    Tyrdal, Stein; Olsen, Bo Sanderhoff

    1998-01-01

    An epidemiological study suggested that the injury mechanism of 'handball goalie's elbow' may be hyperextension. The pathomechanics of hyperextension combined with supination was studied in ten macroscopically normal, male, cadaveric elbow joint specimens. The age of the donors was 28.8 years...... rupture of the lateral collateral ligament. The lesions indicate that combined hyperextension and supination represent a possible mechanism leading to 'handball goalie's elbow'....

  4. The Elbow Self-Assessment Score (ESAS): development and validation of a new patient-reported outcome measurement tool for elbow disorders.

    Science.gov (United States)

    Beirer, Marc; Friese, Henrik; Lenich, Andreas; Crönlein, Moritz; Sandmann, Gunther H; Biberthaler, Peter; Kirchhoff, Chlodwig; Siebenlist, Sebastian

    2017-07-01

    To develop and validate an elbow self-assessment score considering subjective as well as objective parameters. Each scale of the American Shoulder and Elbow Surgeons-Elbow Score, the Broberg and Morrey rating system (BMS), the Patient-Rated Elbow Evaluation (PREE) Questionnaire, the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES) and the Quick Disabilities of the Arm, Shoulder and Hand (Quick-DASH) was analysed, and after matching of the general topics, the dedicated items underwent a fusion to the final ESAS's item and a score containing 22 items was created. In a prospective clinical study, validity, reliability and responsiveness in physically active patients with traumatic as well as degenerative elbow disorders were evaluated. Validation study included 103 patients (48 women, 55 men; mean age 43 years). A high test-retest reliability was found with intraclass correlation coefficients of at least 0.71. Construct validity and responsiveness were confirmed by correlation coefficients of -0.80 to -0.84 and 0.72-0.84 (p Self-Assessment Score (ESAS), a valid and reliable instrument for a qualitative self-assessment of subjective and objective parameters (e.g. range of motion) of the elbow joint is demonstrated. Quantitative measurement of elbow function may not longer be limited to specific elbow disorders or patient groups. The ESAS seems to allow for a broad application in clinical research studying elbow patients and may facilitate the comparison of treatment results in elbow disorders. The treatment efficacy can be easily evaluated, and treatment concepts could be reviewed and revised. Diagnostic study, Level III.

  5. Analysis of results of surgical treatment of posttraumatic stiff elbow

    Directory of Open Access Journals (Sweden)

    Rex Chandrabose

    2008-01-01

    Full Text Available Background: Surgical management of posttraumatic elbow stiffness has been reported with poor outcome following treatment. Sequential release in earlier stages of stiffness yielded much better results. The goal of our study was to assess the outcome in improvement of the range of motion of the elbow after surgical release and to analyze a tailor-made approach according to individual needs to yield good result. Materials and Methods: A prospective study was conducted in 47 cases of elbow stiffness due to various types of injuries. All the cases were treated with sequential release if there was no progress after adequate supervised conservative management except in unreduced dislocations. All the cases were followed up for a minimum period of 24 months. Overall outcome was rated with the functional scoring system by Mayo Clinic Performance Index. Results: Twenty-five (44.68% out of 47 patients had excellent results with a mean preoperative range of motion of 33.9° and postoperative range of motion of 105° with net gain in range of motion of 71.1° (′ t ′ test value is 19.27, P < 0.01. None of the patients had elbow instability. Patients not having heterotopic ossification, who underwent surgery from three to six months post injury had a mean gain of 73.5°. In patients who waited for more than six months had mean gain of 66.8°. However, the results in cases having heterotopic ossification followed a slightly different pattern. In cases where release was performed from three months to six months had mean gain of 77.5°. Cases in which release was performed after six months had gain of 57.1°. Conclusions: In cases of posttraumatic elbow stiffness after a failed initial conservative treatment, early arthrolysis with sequential surgical soft tissue release yields good result than delayed surgery.

  6. BNL NONLINEAR PRE TEST SEISMIC ANALYSIS FOR THE NUPEC ULTIMATE STRENGTH PIPING TEST PROGRAM

    International Nuclear Information System (INIS)

    DEGRASSI, G.; HOFMAYER, C.; MURPHY, C.; SUZUKI, K.; NAMITA, Y.

    2003-01-01

    The Nuclear Power Engineering Corporation (NUPEC) of Japan has been conducting a multi-year research program to investigate the behavior of nuclear power plant piping systems under large seismic loads. The objectives of the program are: to develop a better understanding of the elasto-plastic response and ultimate strength of nuclear piping; to ascertain the seismic safety margin of current piping design codes; and to assess new piping code allowable stress rules. Under this program, NUPEC has performed a large-scale seismic proving test of a representative nuclear power plant piping system. In support of the proving test, a series of materials tests, static and dynamic piping component tests, and seismic tests of simplified piping systems have also been performed. As part of collaborative efforts between the United States and Japan on seismic issues, the US Nuclear Regulatory Commission (USNRC) and its contractor, the Brookhaven National Laboratory (BNL), are participating in this research program by performing pre-test and post-test analyses, and by evaluating the significance of the program results with regard to safety margins. This paper describes BNL's pre-test analysis to predict the elasto-plastic response for one of NUPEC's simplified piping system seismic tests. The capability to simulate the anticipated ratcheting response of the system was of particular interest. Analyses were performed using classical bilinear and multilinear kinematic hardening models as well as a nonlinear kinematic hardening model. Comparisons of analysis results for each plasticity model against test results for a static cycling elbow component test and for a simplified piping system seismic test are presented in the paper

  7. Early results of surgical intervention for elbow deformity in cerebral palsy based on degree of contracture.

    Science.gov (United States)

    Carlson, Michelle G; Hearns, Krystle A; Inkellis, Elizabeth; Leach, Michelle E

    2012-08-01

    Elbow flexion posture, caused by spasticity of the muscles on the anterior surface of the elbow, is the most common elbow deformity seen in patients with cerebral palsy. This study retrospectively evaluated early results of 2 surgical interventions for elbow flexion deformities based on degree of contracture. We hypothesized that by guiding surgical treatment to degree of preoperative contracture, elbow extension and flexion posture angle at ambulation could be improved while preserving maximum flexion. Eighty-six patients (90 elbows) were treated for elbow spasticity due to cerebral palsy. Seventy-one patients (74 elbows) were available for follow-up. Fifty-seven patients with fixed elbow contractures less than 45° were surgically treated with a partial elbow muscle lengthening, which included partial lengthening of the biceps and brachialis and proximal release of the brachioradialis. Fourteen patients (17 elbows) with fixed elbow contractures ≥ 45° had a more extensive full elbow release, with biceps z-lengthening, partial brachialis myotomy, and brachioradialis proximal release. Age at surgery averaged 10 years (range, 3-20 y) for partial lengthening and 14 years (range, 5-20 y) for full elbow release. Follow-up averaged 22 months (range, 7-144 mo) for partial lengthening and 18 months (range, 6-51 mo) for full elbow release. Both groups achieved meaningful improvement in flexion posture angle at ambulation, active and passive extension, and total range of motion. Elbow flexion posture angle at ambulation improved by 57° and active extension increased 17° in the partial lengthening group, with a 4° loss of active flexion. In the full elbow release group, elbow flexion posture angle at ambulation improved 51° and active extension improved 38°, with a loss of 19° of active flexion. Surgical treatment of spastic elbow flexion in cerebral palsy can improve deformity. We obtained excellent results by guiding the surgical intervention by the amount of

  8. Heat-pipe Earth.

    Science.gov (United States)

    Moore, William B; Webb, A Alexander G

    2013-09-26

    The heat transport and lithospheric dynamics of early Earth are currently explained by plate tectonic and vertical tectonic models, but these do not offer a global synthesis consistent with the geologic record. Here we use numerical simulations and comparison with the geologic record to explore a heat-pipe model in which volcanism dominates surface heat transport. These simulations indicate that a cold and thick lithosphere developed as a result of frequent volcanic eruptions that advected surface materials downwards. Declining heat sources over time led to an abrupt transition to plate tectonics. Consistent with model predictions, the geologic record shows rapid volcanic resurfacing, contractional deformation, a low geothermal gradient across the bulk of the lithosphere and a rapid decrease in heat-pipe volcanism after initiation of plate tectonics. The heat-pipe Earth model therefore offers a coherent geodynamic framework in which to explore the evolution of our planet before the onset of plate tectonics.

  9. Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests

    International Nuclear Information System (INIS)

    Baum, M.R.

    1987-01-01

    This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author)

  10. Heat pipes and use of heat pipes in furnace exhaust

    Science.gov (United States)

    Polcyn, Adam D.

    2010-12-28

    An array of a plurality of heat pipe are mounted in spaced relationship to one another with the hot end of the heat pipes in a heated environment, e.g. the exhaust flue of a furnace, and the cold end outside the furnace. Heat conversion equipment is connected to the cold end of the heat pipes.

  11. Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries

    Science.gov (United States)

    2017-11-13

    Airway Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries...Consumer Style Comparison Table of Suction Pump Devices ............................. 103 Appendix H – Web Links for Images for Consumer- Style ...0022 pg. 6 Executive Summary Suction is a critical component of airway management , which is the second leading cause of preventable

  12. PE 100 pipe systems

    CERN Document Server

    Brömstrup, Heiner

    2012-01-01

    English translation of the 3rd edition ""Rohrsysteme aus PE 100"". Because of the considerably increased performance, pipe and pipe systems made from 100 enlarge the range of applications in the sectors of gas and water supply, sewage disposal, industrial pipeline construction and in the reconstruction and redevelopment of defective pipelines (relining). This book applies in particular to engineers, technicians and foremen working in the fields of supply, disposal and industry. Subject matters of the book are all practice-relevant questions regarding the construction, operation and maintenance

  13. The Snapping Elbow Syndrome as a Reason for Chronic Elbow Neuralgia in a Tennis Player - MR, US and Sonoelastography Evaluation.

    Science.gov (United States)

    Łasecki, Mateusz; Olchowy, Cyprian; Pawluś, Aleksander; Zaleska-Dorobisz, Urszula

    2014-01-01

    Ulnar neuropathy is the second most common peripheral nerve neuropathy after median neuropathy, with an incidence of 25 cases per 100 000 men and 19 cases per 100 000 women each year. Skipping (snapping) elbow syndrome is an uncommon cause of pain in the posterior-medial elbow area, sometimes complicated by injury of the ulnar nerve. One of the reason is the dislocation of the abnormal insertion of the medial triceps head over the medial epicondyle during flexion and extension movements. Others are: lack of the Osboune fascia leading to ulnar nerve instability and focal soft tissue tumors (fibromas, lipomas, etc). Recurrent subluxation of the nerve at the elbow results in a tractional and frictional neuritis with classical symptoms of peripheral neuralgia. As far as we know snapping triceps syndrome had never been evaluated in sonoelastography. A 28yo semi-professional left handed tennis player was complaining about pain in posterior-medial elbow area. Initial US examination suggest golfers elbow syndrome which occurs quite commonly and has a prevalence of 0.3-0.6% in males and 0-3-1.1% in women and may be associated (approx. 50% of cases) with ulnar neuropathy. However subsequently made MRI revealed unusual distal triceps anatomy, moderate ulnar nerve swelling and lack of medial epicondylitis symptoms. Followed (second) US examination and sonoelastography have detected slipping of the both ulnar nerve and the additional band of the medial triceps head. Snapping elbow syndrome is a poorly known medical condition, sometimes misdiagnosed as the medial epicondylitis. It describes a broad range of pathologies and anatomical abnormalities. One of the most often reasons is the slipping of the ulnar nerve as the result of the Osborne fascia/anconeus epitrochlearis muscle absence. Simultaneously presence of two or more "snapping reasons" is rare but should be always taken under consideration. There are no sonoelastography studies describing golfers elbow syndrome

  14. Mechanistic multidimensional analysis of two-phase flow in horizontal tube with 90 deg elbow

    International Nuclear Information System (INIS)

    Tselishcheva, E.A.; Antal, St.P.; Podowski, M.Z.; Marshall, S.

    2007-01-01

    The development of modeling and simulation capabilities of two-phase flow and heat transfer is very important for the design, operation and safety of nuclear reactors. Whereas a significant progress in this field has been made over the recent years, further advancements are clearly needed for new concepts of advanced (Generation-IV in particular) reactors. Difficulties in analyzing gas/liquid flows are due to the fact that such two-phase mixtures can assume several different flow patterns, each characterized by flow-regime specific interfacial phenomena of mass, momentum and energy transfer. The level of difficulty increases even further in the case of a complex tube geometries and spatial orientations. The purpose of this paper is to discuss the results of the analysis of a two-phase flow in a horizontal pipe with a 90-degree elbow. The overall objective of the present work is the development of a 3-dimensional computational model of a two-phase high-Reynolds number turbulent flow. The overall new model has been encoded in the next-generation Computational Multiphase Fluid Dynamics (CMFD) computer code, NPHASE. The model has been tested parametrically and the results of NPHASE calculations have been compared against experimental data. It has been demonstrated that the proposed model is consistent both physically and numerically, the predictions are in a reasonable agreement with the measurements

  15. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    Science.gov (United States)

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  16. Pipe-to-pipe impact tests

    Energy Technology Data Exchange (ETDEWEB)

    Bampton, M C.C.; Alzheimer, J M; Friley, J R; Simonen, F A

    1985-11-01

    Existing licensing criteria express what damage shall be assumed for various pipe sizes as a consequence of a postulated break in a high energy system. The criteria are contained in Section 3.6.2 of the Standard Review Plan, and the purpose of the program described with this paper is to evaluate the impact criteria by means of a combined experimental and analytical approach. A series of tests has been completed. Evaluation of the test showed a deficiency in the range of test parameters. These deficiencies are being remedied by a second series of tests and a more powerful impact machine. A parallel analysis capability has been developed. This capability has been used to predict the damage for the first test series. The quality of predictions has been improved by tests that establish post-crush and bending relationships. Two outputs are expected from this project: data that may, or may not, necessitate changes to the criteria after appropriate value impact evaluations and an analytic capability for rapidly evaluating the potential for pipe whip damage after a postulated break. These outputs are to be contained in a value-impact document and a program final report. (orig.).

  17. Performance of buried pipe installation.

    Science.gov (United States)

    2010-05-01

    The purpose of this study is to determine the effects of geometric and mechanical parameters : characterizing the soil structure interaction developed in a buried pipe installation located under : roads/highways. The drainage pipes or culverts instal...

  18. Magnetic resonance imaging of the elbow. Part I: Normal anatomy, imaging technique, and osseous abnormalities

    International Nuclear Information System (INIS)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew

    2004-01-01

    Part I of this comprehensive review on magnetic resonance imaging of the elbow discusses normal elbow anatomy and the technical factors involved in obtaining high-quality magnetic resonance images of the elbow. Part I also discusses the role of magnetic resonance imaging in evaluating patients with osseous abnormalities of the elbow. With proper patient positioning and imaging technique, magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the osseous structures of the elbow. Magnetic resonance imaging can detect early osteochondritis dissecans of the capitellum and can be used to evaluate the size, location, stability, and viability of the osteochondritis dissecans fragment. Magnetic resonance imaging can detect early stress injury to the proximal ulna in athletes. Magnetic resonance imaging can detect radiographically occult fractures of the elbow in both children and adults. Magnetic resonance imaging is also useful in children to further evaluate elbow fractures which are detected on plain-film radiographs. (orig.)

  19. Structural analyses on piping systems of sodium reactors. 2. Eigenvalue analyses of hot-leg pipelines of large scale sodium reactors

    International Nuclear Information System (INIS)

    Furuhashi, Ichiro; Kasahara, Naoto

    2002-01-01

    Two types of finite element models analyzed eigenvalues of hot-leg pipelines of a large-scale sodium reactor. One is a beam element model, which is usual for pipe analyses. The other is a shell element model to evaluate particular modes in thin pipes with large diameters. Summary of analysis results: (1) A beam element model and a order natural frequency. A beam element model is available to get the first order vibration mode. (2) The maximum difference ratio of beam mode natural frequencies was 14% between a beam element model with no shear deformations and a shell element model. However, its difference becomes very small, when shear deformations are considered in beam element. (3) In the first order horizontal mode, the Y-piece acts like a pendulum, and the elbow acts like the hinge. The natural frequency is strongly affected by the bending and shear rigidities of the outer supporting pipe. (4) In the first order vertical mode, the vertical sections of the outer and inner pipes moves in the axial-directional piston mode, the horizontal section of inner pipe behaves like the cantilever, and the elbow acts like the hinge. The natural frequency is strongly affected by the axial rigidity of outer supporting pipe. (5) Both effective masses and participation factors were small for particular shell modes. (author)

  20. Research on Flow Pattern of Nitrogen Tetroxide Liquid in the Different Bend Radii Pipes

    Directory of Open Access Journals (Sweden)

    Hao Pengfei

    2016-01-01

    Full Text Available N2O4 is a common rocket fuel propellants, it has the characteristics of low boiling point and a large viscosity , the friction between viscosity fluids and pipeline dramatic leads to a huge sticky heat, therefore, the vaporization phenomenon often occurs in the pipeline, particularly in bending of the viscous heat. For this reason, the research of the different bending radii vaporized fluid conditions for optimizing the piping and precise the filling flow is significant. In this paper, the MIXTURE mixed flow model is used to achieve the numerical simulation the pipelines filling of the three different bending radii, it still have not solved the mass transfer problem between the different phases. Therefore, the custom functions are needed to define the mass transfer problems from the liquid phase to the vapor phase. Though the contrast among the volume phase cloud of six different elbow models , we have the following conclusions: 1 In the entire pipeline transportation, the distribution vaporization rate from the inlet pipe to the outlet pipe follows the distribution of the first increasing and then decreasing, the gas rates of the elbow area is highest; 2Analyzing the sticky heat for different bend radii, we have the conclusion that the lowest bending vaporization the of the optimal radius is 0.45m. The above conclusions are drawn in good agreement with the actual law, can effectively guide the engineering practice, have important significance for the future design for the optimization of the fuel pipeline transportation.

  1. Effects of Lavender Inhalant on the Pain during Endotracheal Suctioning in Intensive Care Unit Patients

    Directory of Open Access Journals (Sweden)

    M. Taheri Rezgh Abadi

    2017-09-01

    Full Text Available Aims: Patients undergoing artificial ventilation require tracheal tube suction because of inability to clear their effective airways, which is usually a painful process for the patients. The aim of this study was to investigate the effect of spike lavender’s inhalant on pain during tracheal tube suctioning in ICU intubated patients. Materials & Methods: In this double-blinded randomized clinical trial, 60 intubated patients hospitalized in ICU of Shahid Modarres Hospital of Kashmar City, Iran, in 2017 were selected by available and simple sampling method, and were randomly divided into 2 control and case groups (each 30 individuals. Before the standard suctioning process, the test group patients received inhalant of 2% spike lavender for 5 minutes and the control group received inhalant of distilled water. The level of pain was recorded before and during tracheal tube suctioning. Data were analyzed by SPSS 16 software using independent T, paired T, Fisher and Mann-Whitney U tests. Findings: There was no significant difference in pain score before tracheal tube suction between 2 groups (p>0.05. However, there were significant differences between the level of pain during tracheal tube suctioning and the pain was increased in both groups, but this increase was significantly higher in the control group (p<0.001. Conclusion: Spike lavender’s inhalant is effective on pain reduction during suctioning process of ICU intubated patients.

  2. Enhanced effect of suction-cavitation on the ozonation of phenol

    International Nuclear Information System (INIS)

    Wu Zhilin; Franke, Marcus; Ondruschka, Bernd; Zhang, Yongchun; Ren Yanze; Braeutigam, Patrick; Wang, Weimin

    2011-01-01

    800 mL of 1.0 mM phenol-containing aqueous solution was circulated at 20 ° C for 30 min in a suction-reactor, while 3.2 mg min -1 ozone was introduced into the solution under the suction orifice. The removal rates of phenol vary polynomially with the orifice diameter as well as the suction pressure. The rate constant for the zero-order kinetics achieves the highest value at -0.070 MPa by using 5 mm orifice. Although the suction-cavitation alone cannot remove phenol in 30 min, it can considerably enhance the ozonation of phenol. The rate constants for the zero-order kinetics by the simple ozonation and the combined method are 0.018 and 0.028 min -1 , respectively. Furthermore, no ozone was observed in the tail gas during the first 15 min for the ozonation in the suction reactor, and then the concentration of unreacted ozone slowly increased, indicating that the utilization rate of ozone is significantly improved by the suction-cavitation. The increasing input concentration of ozone obviously accelerates the ozonation of phenol, but the total required quantities of ozone are very close by various ozone input concentrations to reach the same degradation rate, indicating the ozonation assisted by the suction-cavitation can be considered as a quantitative reaction.

  3. Optimization of Pipe Networks

    DEFF Research Database (Denmark)

    Hansen, C. T.; Madsen, Kaj; Nielsen, Hans Bruun

    1991-01-01

    algorithm using successive linear programming is presented. The performance of the algorithm is illustrated by optimizing a network with 201 pipes and 172 nodes. It is concluded that the new algorithm seems to be very efficient and stable, and that it always finds a solution with a cost near the best...

  4. Recent development of three-dimensional piping code SHAPS

    International Nuclear Information System (INIS)

    Wang, C.Y.; Zeuch, W.R.

    1985-01-01

    This paper describes the recent development of the three-dimensional, structural, and hydrodynamic analysis piping code SHAPS. Several new features have been incorporated into the program, including (1) an elbow hydrodynamic model for analyzing the effect of global motion on the pressure-wave propagation, (2) a component hydrodynamic model for treating fluid motion in the vicinity of rigid obstacles and baffle plates, (3) the addition of the implicit time integration scheme in the structural-dynamic analysis, (4) the option of an implicit-implicit fluid-structural linking scheme, and (5) provisions for two constitutive equations for materials under various loading conditions. Sample problems are given to illustrate these features. Their results are discussed in detail. 7 refs., 8 figs

  5. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  6. Development of standard practice guidelines for open and closed system suctioning.

    Science.gov (United States)

    Özden, Dilek; Görgülü, R Selma

    2012-05-01

    This study was carried out to determine the knowledge and practice of nurses before and after training and the development of standard practice guidelines for open and closed system suctioning methods in patients with endotracheal tubes. Many life-threatening complications can occur when a suctioning procedure is not performed with the correct technique. It has been reported that standard practice guidelines for suctioning are insufficient in clinical practice. Non-participant structured observational study. We assessed a total of 48 nurses who were employed in the cardiovascular surgery intensive care unit of a state hospital in Turkey. We used a questionnaire and nurse observation forms to assess the use of the open and closed system suctioning. There was a significant difference between the mean scores of the answers ('true', 'wrong' and 'I do not know') for the use of open and closed system suctioning before and after training. In addition, all steps of both suctioning procedures were carried out correctly during the third observation. The compliance of the nurses to the standard practice guidelines for open and closed suctioning and their knowledge levels on the subject were increased after training, while the implementation of standards was satisfactory. The development of open and closed system suctioning standard practice guidelines directly contributed to the enhancement of patient safety and the quality of nursing care. It is suggested that, as in other nursing care practices, suctioning should be carried out in accordance with standard practice guidelines, and health institutions should develop their standard practice guidelines and work in accordance with them. © 2012 Blackwell Publishing Ltd.

  7. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.

    2014-05-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  8. Magnetohydrodynamic peristaltic motion of a Newtonian fluid through porous walls through suction and injection

    Science.gov (United States)

    Sivaiah, R.; Hemadri Reddy, R.

    2017-11-01

    In this paper, we investigate the peristaltic transport of a conducting Newtonian fluid bounded by permeable walls with suction and injection moving with constant velocity of the wave in the wave frame of reference under the consideration of long wavelength and low Reynolds number. The analytical solution for the velocity field, pressure gradient and the frictional force are obtained. The effect of suction/injection parameter, amplitude ratio and the permeability parameter including slip on the flow quantities are discussed graphically. It is found that the greater the suction/injection parameter, the smaller the pressure rise against the pump works. Further, the pressure rise increases with increasing Magnetic parameter.

  9. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.; Wang, Shiquan; Gardineer, Bayard; Christensen, David L.; Aukes, Daniel M.; Cutkosky, Mark

    2014-01-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  10. Synovial chondromatosis of the elbow in a child

    Directory of Open Access Journals (Sweden)

    Rishi Narasimhan

    2011-01-01

    Full Text Available Synovial chondromatosis is cartilaginous metaplasia of mesenchymal remnants of synovial tissue of the joints. Its main characteristic is the formation of cartilaginous nodules in the synovium and inside the articular space (loose bodies. It usually presents between the third and fifth decades and is rare in children. It presents as a mono-articular pathology affecting large joints such as the knee, hip, and elbow. The main symptoms are pain, swelling, and limitation of movements in the affected joint. Diagnosis is made by panoramic radiographs, computed tomography scan, and mainly magnetic resonance imaging and on surgery. The authors describe of synovial chondromatosis presenting in the elbow of an 11 year-old girl which is unreported to the best of our knowledge.

  11. Bimanual elbow exoskeleton: Force based protocol and rehabilitation quantification.

    Science.gov (United States)

    Alavi, N; Herrnstadt, G; Randhawa, B K; Boyd, L A; Menon, C

    2015-08-01

    An aging population, along with the increase in cardiovascular disease incidence that accompanies this demographic shift, is likely to increase both the economic and medical burden associated with stroke in western societies. Rehabilitation, the standard treatment for stroke, can be expanded and augmented with state of the art technologies, such as robotic therapy. This paper expands upon a recent work involving a force-feedback master-slave bimanual exoskeleton for elbow rehabilitation, named a Bimanual Wearable Robotic Device (BWRD). Elbow force data acquired during the execution of custom tasks is analyzed to demonstrate the feasibility of tracking patient progress. Two training tasks that focus on applied forces are examined. The first is called "slave arm follow", which uses the absolute angular impulse as a metric; the second is called "conditional arm static", which uses the rise time to target as a metric, both presented here. The outcomes of these metrics are observed over three days.

  12. Elbow joint rehabilitation equipment actuated by pneumatic muscles

    Directory of Open Access Journals (Sweden)

    Vetrice Georgiana

    2017-01-01

    Full Text Available The mobility of the limbs is an essential prerequisite for the individual’s physical autonomy. For persons suffering from post-traumatic affections of the elbow joint such limited mobility results in barriers in fulfilling personal or professional tasks. Passive motion has certain specific advantages and beneficial effects, thus being highly recommended for the recovery of injured joints. The paper presents a model of rehabilitation equipment that induces continuous passive motion of the elbow, as part of a recovery programme. The equipment is actuated by pneumatic muscles, using compressed air as the source of energy that generates force and motion. The main benefits of the pneumatic actuation system compared to other driving systems are its low cost, simple and robust construction and swift response to commands. Its constructive simplicity and reduced cost adds to the system’s eligibility for deployment in medical units.

  13. Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

    Science.gov (United States)

    Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N

    2017-07-01

    In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p cadaver instruction session alone. Level of evidence V.

  14. Comparison between two models of elbow rehabilitation equipment

    Directory of Open Access Journals (Sweden)

    Vetrice Georgiana

    2017-01-01

    Full Text Available International studies have revealed that using continuous passive motion (CPM equipment as part of a rehabilitation program improves the recovery period and also diminishes the rehabilitation costs by about 50%. This explains the need for conceiving elbow joint rehabilitation equipment to help persons suffering from posttraumatic disabilities. In order to create the best model to meet the patients’ requirements this paper presents two constructive solutions of such equipment and a comparison between their designs. Both achieve the desired movements of the elbow joint: flexion-extension and pronation-supination and are actuated by pneumatic muscles, due to the multiple advantages of pneumatic actuation: low cost, compliance and favorable response to commands.

  15. Heat pipe applications workshop report

    International Nuclear Information System (INIS)

    Ranken, W.A.

    1978-04-01

    The proceedings of the Heat Pipe Applications Workshop, held at the Los Alamos Scientific Laboratory October 20-21, 1977, are reported. This workshop, which brought together representatives of the Department of Energy and of a dozen industrial organizations actively engaged in the development and marketing of heat pipe equipment, was convened for the purpose of defining ways of accelerating the development and application of heat pipe technology. Recommendations from the three study groups formed by the participants are presented. These deal with such subjects as: (1) the problem encountered in obtaining support for the development of broadly applicable technologies, (2) the need for applications studies, (3) the establishment of a heat pipe technology center of excellence, (4) the role the Department of Energy might take with regard to heat pipe development and application, and (5) coordination of heat pipe industry efforts to raise the general level of understanding and acceptance of heat pipe solutions to heat control and transfer problems

  16. Ligamentous and capsular restraints to experimental posterior elbow joint dislocation

    DEFF Research Database (Denmark)

    Deutch, S.R.; Olsen, B.S.; Jensen, S.L.

    2003-01-01

    the anterior capsule and the lateral collateral ligament complex (LCLC), whereas in the flexed elbow the anterior capsule did not have a stabilizing effect. In flexed joint positions, the LCLC seems to be the only immediate stabilizer against PEFR, and thereby against posterolateral instability and possibly...... against posterior dislocation. The medial collateral ligament did not have any immediate stabilizing effect, but it prevented the final step of the posterior dislocation....

  17. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  18. Direct magnetic resonance arthrography of the canine elbow

    Directory of Open Access Journals (Sweden)

    Yauheni Zhalniarovich

    2017-01-01

    Full Text Available This study compares the effects of four dilutions of the gadolinium-containing contrast media (1:100; 1:400; 1:800; 1:1,200 administered to the elbow on the quality of magnetic resonance images. All the examined dilutions had a positive effect on image quality, and 1:800 was regarded as the optimal dilution of gadolinium for viewing the elbow because it imparted good contrast to the joint cavity without obliterating the contours of articular surfaces. Transverse, sagittal, and dorsal low-field magnetic resonance images were obtained in 24 canine cadaver front limbs. The musculus biceps brachii, m. triceps brachii, m. extensor carpi radialis, m. flexor carpi ulnaris, the articular surfaces, the medial coronoid process and the anconeal process of the ulna were well visualized by High Resolution Gradient Echo, XBONE T2 and Spin Echo T1 sequences in the sagittal plane. The biceps brachii, pronator teres, flexor carpi radialis, extensor digitorum communis, extensor carpi radialis, deltoid muscle and the articular surface of the medial condyle of the humerus were very well visualized by 3D SST1 and XBONE T2 sequences in the transverse plane. The triceps brachii muscle, extensor digitorum lateralis muscle, superficial digital flexor, deep digital flexor and the medial condyle of the humerus were very well visualized by the Spin Echo T1 sequence in the dorsal plane. This article describes for the first time the use of the gadolinium contrast agent administered to the canine elbow joint during magnetic resonance modality. Magnetic resonance arthrography can be a helpful visualization technique in treating canine soft tissue elbow injury.

  19. Articular Contact Area and Pressure in Posteromedial Rotatory Instability of the Elbow.

    Science.gov (United States)

    Bellato, Enrico; Fitzsimmons, James S; Kim, Youngbok; Bachman, Daniel R; Berglund, Lawrence J; Hooke, Alexander W; O'Driscoll, Shawn W

    2018-03-21

    Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p contact area increased from 80 ± 8 mm to 150 ± 58 mm (p contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.

  20. On the computer simulation of LMFBR piping systems

    International Nuclear Information System (INIS)

    A-Moneim, M.T.; Chang, Y.-W.; Fistedis, S.H.

    1977-01-01

    A two-dimensional coupled hydrodynamic-structural response analysis of piping systems is described. Implicit Continuous-Fluid Eulerian (ICE) technique is utilized in the hydrodynamics while a finite-element technique is used in the structural analysis. Different piping components such as elbows, valves, reducers, expansions, heat exchangers, and tees are modelled and coupled with the straight pipe model. An axisymmetric general component model that can be used in modelling valves, reducers, expansions, and heat exchangers is described. At the inlet and outlet region of such component the cross-sectional area may change suddently or gradually, or many not change at all. Among the options available in this model are deformable exterior walls, interior rigid wall simulation, and tube bundle effect. Exterior walls of pipes and components are treated as thin axisymmetric shell. A convected coordinate explicit finite-element scheme for large displacement small strain, elastic-plastic material behavior in which membrane and bending strengths are accounted for is employed. The strains are linearly related to the displacement of the element relative to its convective coordinates, and similarly, the nodal forces are linearly related to the elements stresses. The coupling of the hydrodynamics and structural problems is done in such a way that the hydrodynamics supplies the structure with a pressure loading and the structure supplying the hydrodynamics with a moving boundary condition. Because of the difficulties of handling interior walls that may occupy partial zones, the walls are assumed rigid and limited in their orientation to be parallel to the radial or axial directions, their position to zone boundaries, and their thickness to zero

  1. Study on the performance improvement of multiblade fans. Effects of suction cones; Tayoku fan no seino kaizen ni kansuru kenkyu. Suction cone no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kuratani, F.; Ogawa, T. [Hyogo University of Teacher Education, Hyogo (Japan); Yamamoto, S.

    1999-07-25

    In order to improve the performance of a multiblade fan, the effects of three types of suction cones of the fan casing on the fan efficiency and noise are investigated experimentally. The first type of the suction cone is the insertion type, which is inserted into the inside of the fan impeller. The second type is the extrusion type, which extrudes outside from the casing surface. The third type is the combination type of two types. The results of those three types are compared with those of the commonly used suction cone. The followings are made clear: (1) The insertion type and the extrusion type are effective in improving the efficiency and reducing noise. (2) The optimal lengths of the insertion and the extrusion exist. (3) The combination type is more effective in improving the efficiency. (4) The combination type with the skewed cutoff of the fan casing shows the best effect. (author)

  2. Total elbow arthroplasty for the treatment of distal humeral fractures.

    Science.gov (United States)

    Gallucci, G L; Larrondo Calderón, W; Boretto, J G; Castellaro Lantermo, J A; Terán, J; de Carli, P

    2016-01-01

    To report the clinical-functional outcomes of the treatment of humeral distal fractures with a total elbow prosthesis. This retrospective study was performed in two surgical centres. A total of 23patients were included, with a mean age of 79years, and of which 21 were women. The inclusion criteria were: patients with humeral distal fractures, operated on using a Coonrad-Morrey prosthesis, and with a follow-up of more than one year. According to AO classification, 15fractures were type C3, 7 C2 and 1 A2. All patients were operated on without de-insertion of the extensor mechanism. The mean follow-up was 40 months. Flexor-extension was 123-17°, with a total mobility arc of 106° (80% of the contralateral side). Pain, according to a visual analogue scale was 1. The Mayo Elbow Performance Index (MEPI) was 83 points. Excellent results were obtained in 8 patients, good in 13, medium in 1, and poor in 1. The mean DASH (disability) score was 24 points. Treatment of humeral distal fractures with total elbow arthroplasty could be a good treatment option, but indications must be limited to patients with complex fractures, poor bone quality, with osteoporosis and low functional demands. In younger patients, the use is limited to serious cases where there is no other treatment option. Level of Evidence IV. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.

  3. Functional anatomy of the lateral collateral ligament of the elbow.

    Science.gov (United States)

    Hackl, M; Bercher, M; Wegmann, K; Müller, L P; Dargel, J

    2016-07-01

    The aim of this study was to analyze the functional anatomy of the lateral collateral ligament complex (LCLC) and the surrounding forearm extensors. Using 81 human cadaveric upper extremities, the anatomy of the forearm extensors-especially the anconeus, supinator and extensor carpi ulnaris (ECU)-was analyzed. After removal of aforementioned extensors the functional anatomy of the LCLC was analyzed. The origin of the LCLC was evaluated for isometry. The insertion types of the lateral ulnar collateral ligament (LUCL) were analyzed and classified. The ECU runs parallel to the RCL to dynamically preserve varus stability. The supinator and anconeus muscle fibers coalesce with the LCLC and lengthen during pronation. The anconeus fibers run parallel to the LUCL in full flexion. The LCLC consists of the annular ligament (AL) and the isometric radial collateral ligament (RCL). During elbow flexion, its posterior branches (LUCL) tighten while the anterior branches loosen. When performing a pivot shift test, the loosened LUCL fibers do not fully tighten in full extension. The LUCL inserts along with the AL at the supinator crest. Three different insertion types could be observed. The LUCL represents the posterior branch of the RCL rather than a distinct ligament. It is non-isometric and lengthens during elbow flexion. The RCL was found to be of vital importance for neutralization of posterolateral rotatory forces. Pronation of the forearm actively stabilizes the elbow joint as the supinator, anconeus and biceps muscle work in unison to increase posterolateral rotatory stability.

  4. Unreduced elbow dislocation treated by Ilizarov method: A case report

    Directory of Open Access Journals (Sweden)

    Jovanović Vesna

    2010-01-01

    Full Text Available Introduction. Unreduced elbow dislocation is every elbow dislocation older than one week. It may be treated non-operatively (with prereduction traction or surgically. The treatment goals are: to reduce pain, to establish joint stability and movements. There are a lot of techniques described in literature, series are relatively small, mostly case reports. Multicentric studies have not been done. That is why there are no precisely defined therapeutic protocols. Every contribution in the field is valuable. Case Outline. A 43-year-old patient was admitted for the treatment of a three-month old unreduced elbow dislocation. Treatment has been done by Ilizarov method, using the reduction mechanism. The reduction process lasted two weeks. The Ilizarov device was removed two months after the operation, then physical therapy was started. Normal anatomical and functional findings were established five months following the operation. Conclusion. The presented method of treatment has been found as very useful, having in mind that it may solve two problems: difficult reduction and redislocation. Reduction may be done without the joint opening, step by step; retention of the reduced joint may be easily done. Physical therapy may be started without Ilizarov device removal, movements of flexion and extension may be improved without any lateral instability. There is no iatrogenic intraarticular damage, so there are no secondary joint degeneration, pains and invalidity.

  5. Anthropometric characterisation of elbow angles and lines among Indian children

    Directory of Open Access Journals (Sweden)

    Bhanu Awasthi

    2017-01-01

    Full Text Available Background: For understanding injuries in paediatric elbow and checking the degree of reduction after manipulation, various radiological criteria using anthropometric parameters are used. Since anthropometric parameters of Caucasians are different from European and Mongoloids, their parameters cannot be applied on our population. Hence, there is a need to characterise anthropometric parameters of elbow among children in the Indian population. Materials and Methods: The study population comprised all cases of injury to the elbow joint between 3 and 13 years of age reporting to the Department of Orthopaedics during the study. The X-rays films were preserved, and the angles and lines (as anthropometric parameters were drawn on the radiographs. Results: Mean ± (standard deviation [SD] for Baumann angle in children included in this study was 75° ± 4.70°. Mean ± (SD of Baumann angle in males was 76° ± 4.44° and females was 74° ± 5.37°. Mean ± (SD for lateral capitellohumeral angle in children from 3 to 13 years of age was 49 ± 5.75. Conclusions: As the values of normal side have been found to affect the functional and cosmetic outcome of the affected extremity, slight changes in values of our population in comparison to that of the Western population can significantly affect the outcome.

  6. Evaluation of Karl Storz CMAC TipTM Device Versus Traditional Airway Suction in a Cadaver Model

    Directory of Open Access Journals (Sweden)

    Demis N. Lipe

    2014-07-01

    Full Text Available Introduction: We compared the efficacy of Karl Storz CMAC TipTM with inline suction to CMAC with traditional suction device in cadaveric models simulating difficult airways, using media mimicking pulmonary edema and vomit. Methods: This was a prospective, cohort study in which we invited emergency medicine faculty and residents to participate. Each participant intubated 2 cadavers (one with simulated pulmonary edema and one with simulated vomit, using CMAC with inline suction and CMAC with traditional suction. Thirty emergency medicine providers performed 4 total intubations each in a crossover trial comparing the CMAC with inline suction and CMAC with traditional suction. Two intubations were performed with simulated vomit and two with simulated pulmonary edema. The primary outcome was time to successful intubation; and the secondary outcome was proportion of successful intubation. Results: The median time to successful intubation using the CMAC with inline suction versus traditional suction in the pulmonary edema group was 29s and 30s respectively (p=0.54. In the vomit simulation, the median time to successful intubation was 40s using the CMAC with inline suction and 41s using the CMAC with traditional suction (p=0.70. There were no significant differences in time to successful intubation between the 2 devices. Similarly, the proportions of successful intubation were also not statistically significant between the 2 devices. The proportions of successful intubations using the inline suction were 96.7% and 73.3%, for the pulmonary edema and vomit groups, respectively. Additionally using the handheld suction device, the proportions for the pulmonary edema and vomit group were 100% and 66.7%, respectively. Conclusion: CMAC with inline suction was no different than CMAC with traditional suction and was associated with no statistically significant differences in median time to intubation or proportion of successful intubations. [West J Emerg Med

  7. A consideration on pipe-wall thinning mechanisms from an aspect of fluid-mechanics

    International Nuclear Information System (INIS)

    Inada, Fumio; Yoneda, Kimitoshi; Morita, Ryo; Fujiwara, Kazutoshi; Furuya, Masahiro

    2008-01-01

    The contribution of the fluid mechanics to the piping wall thinning phenomena was investigated. It was shown that the fluid force to the wall was quite different between flow accelerated corrosion (FAC) and erosion. The turbulent mass transfer, which is one of the primary factors of FAC, was analogous to the turbulent heat transfer. The model that the molecular transport in the viscous sublayer nearby soon of wall was predominant was practicable. In addition, the mass transport was predicted using commercial codes of computational fluid dynamics. Some prediction results of the mass transfer in orifice and the elbow using above techniques were explained. (author)

  8. Nuclear piping and pipe support design and operability relating to loadings and small bore piping

    International Nuclear Information System (INIS)

    Stout, D.H.; Tubbs, J.M.; Callaway, W.O.; Tang, H.T.; Van Duyne, D.A.

    1994-01-01

    The present nuclear piping system design practices for loadings, multiple support design and small bore piping evaluation are overly conservative. The paper discusses the results developed for realistic definitions of loadings and loading combinations with methodology for combining loads under various conditions for supports and multiple support design. The paper also discusses a simplified method developed for performing deadweight and thermal evaluations of small bore piping systems. Although the simplified method is oriented towards the qualification of piping in older plants, this approach is applicable to plants designed to any edition of the ASME Section III or B31.1 piping codes

  9. Remora fish suction pad attachment is enhanced by spinule friction.

    Science.gov (United States)

    Beckert, Michael; Flammang, Brooke E; Nadler, Jason H

    2015-11-01

    The remora fishes are capable of adhering to a wide variety of natural and artificial marine substrates using a dorsal suction pad. The pad is made of serial parallel pectinated lamellae, which are homologous to the dorsal fin elements of other fishes. Small tooth-like projections of mineralized tissue from the dorsal pad lamella, known as spinules, are thought to increase the remora's resistance to slippage and thereby enhance friction to maintain attachment to a moving host. In this work, the geometry of the spinules and host topology as determined by micro-computed tomography and confocal microscope data, respectively, are combined in a friction model to estimate the spinule contribution to shear resistance. Model results are validated with natural and artificially created spinules and compared with previous remora pull-off experiments. It was found that spinule geometry plays an essential role in friction enhancement, especially at short spatial wavelengths in the host surface, and that spinule tip geometry is not correlated with lamellar position. Furthermore, comparisons with pull-off experiments suggest that spinules are primarily responsible for friction enhancement on rough host topologies such as shark skin. © 2015. Published by The Company of Biologists Ltd.

  10. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  11. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.

    Science.gov (United States)

    Gillies, Donna; Spence, Kaye

    2011-07-06

    Mechanical ventilation is commonly used in Neonatal Intensive Care Units to assist breathing in a variety of conditions. Mechanical ventilation is achieved through the placement of an endotracheal tube (ETT) which is left in-situ. The ETT is suctioned to prevent a build-up of secretions and blockage of the airway. Methods of suctioning the endotracheal tube vary according to institutional practice and the individual clinician performing the task. The depth of suctioning is one of these variables. The catheter may be passed to the tip of the ETT or beyond the tip into the trachea or bronchi to facilitate removal of secretions. However, trauma to the lower airways may result from the suction catheter being passed into the airway beyond the tip of the endotracheal tube. To compare the effectiveness and complications of deep (catheter passed beyond the tip of the ETT) versus shallow (catheter passed to length of ETT only) suctioning of the endotracheal tube in ventilated infants. In this first update the searches were expanded to the Cochrane Central Register of Controlled Trials (The Cochrane Library, March 30), MEDLINE (from January 1966 to May 30 2011), CINAHL (from 1982 to May 30 2011) and EMBASE (1980 to May 2011) using text words and subject headings relevant to endotracheal suctioning. There were no language restrictions. Controlled trials using random or quasi-random allocation of neonates receiving ventilatory support via an endotracheal tube to either deep or shallow endotracheal suctioning. The updated search resulted in 149 potentially relevant references. Two of the studies from this search were identified as potentially relevant. We included one of the potentially relevant studies and the other was excluded because it did not fit the inclusion criteria. One small crossover trial (n = 27) of shallow versus deep suctioning met the criteria for inclusion in this review. The reported outcomes were oxygen saturation and heart rate, during and after suctioning

  12. Feeding kinematics, suction, and hydraulic jetting performance of harbor seals (Phoca vitulina.

    Directory of Open Access Journals (Sweden)

    Christopher D Marshall

    Full Text Available The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01 than biting feeding events (0.18±0.08 s. Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land. Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001 and gape angle (12.9±2.02°, pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm and gape angle (28.8±1.80°; P<0.001 and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their

  13. Ratcheting study in pressurized piping components under cyclic loading at room temperature

    International Nuclear Information System (INIS)

    Ravi Kiran, A.; Agrawal, M.K.; Reddy, G.R.; Vaze, K.K.; Ghosh, A.K.; Kushwaha, H.S.

    2006-07-01

    The nuclear power plant piping components and systems are often subjected to reversing cyclic loading conditions due to various process transients, seismic and other events. Earlier the design of piping subjected to seismic excitation was based on the principle of plastic collapse. It is believed that during such events, fatigue-ratcheting is likely mode of failure of piping components. The 1995 ASME Boiler and Pressure Vessel code, Section-III, has incorporated the reverse dynamic loading and ratcheting into the code. Experimental and analytical studies are carried out to understand this failure mechanism. The biaxial ratcheting characteristics of SA 333, Gr. 6 steel and SS 304 stainless steel at room temperature are investigated in the present work. Experiments are carried out on straight pipes subjected to internal pressure and cyclic bending load applied in a three point and four point bend test configurations. A shake table test is also carried out on a pressurized elbow by applying sinusoidal base excitation. Analytical simulation of ratcheting in the piping elements is carried out. Chaboche nonlinear kinematic hardening model is used for ratcheting simulation. (author)

  14. Diffusion in flexible pipes

    Energy Technology Data Exchange (ETDEWEB)

    Brogaard Kristensen, S.

    2000-06-01

    This report describes the work done on modelling and simulation of the complex diffusion of gas through the wall of a flexible pipe. The diffusion and thus the pressure in annulus depends strongly on the diffusion and solubility parameters of the gas-polymer system and on the degree of blocking of the outer surface of the inner liner due to pressure reinforcements. The report evaluates the basis modelling required to describe the complex geometries and flow patterns. Qualitatively results of temperature and concentration profiles are shown in the report. For the program to serve any modelling purpose in 'real life' the results need to be validated and possibly the model needs corrections. Hopefully, a full-scale test of a flexible pipe will provide the required temperatures and pressures in annulus to validate the models. (EHS)

  15. Diffusion in flexible pipes

    Energy Technology Data Exchange (ETDEWEB)

    Brogaard Kristensen, S

    2000-06-01

    This report describes the work done on modelling and simulation of the complex diffusion of gas through the wall of a flexible pipe. The diffusion and thus the pressure in annulus depends strongly on the diffusion and solubility parameters of the gas-polymer system and on the degree of blocking of the outer surface of the inner liner due to pressure reinforcements. The report evaluates the basis modelling required to describe the complex geometries and flow patterns. Qualitatively results of temperature and concentration profiles are shown in the report. For the program to serve any modelling purpose in 'real life' the results need to be validated and possibly the model needs corrections. Hopefully, a full-scale test of a flexible pipe will provide the required temperatures and pressures in annulus to validate the models. (EHS)

  16. Blood loss associated with Ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage.

    Science.gov (United States)

    Wittmann, F W; Ring, P A

    1984-01-01

    In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978

  17. Natural convection boundary layer with suction and mass transfer in a porous medium

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1989-03-01

    The free convection boundary layer flow with simultaneous heat and mass transfer in a porous medium is studied when the boundary wall moves in its own plane with suction. The study also incorporates chemical reaction for the very simple model of a binary reaction with Arrhenius activation energy. For large suction asymptotic approximate solutions are obtained for the flow variables for various values of the activation energy. (author). 10 refs, 2 figs

  18. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Directory of Open Access Journals (Sweden)

    Ryosuke Motani

    Full Text Available Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the

  19. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Science.gov (United States)

    Motani, Ryosuke; Ji, Cheng; Tomita, Taketeru; Kelley, Neil; Maxwell, Erin; Jiang, Da-yong; Sander, Paul Martin

    2013-01-01

    Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the establishment of modern

  20. Supermarket refrigeration. Optimization of suction pressure in existing refrigerators; Supermarktkaelte. Saugdruck optimieren in Bestandskaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Philipp; Mueller, Markus [Eckelmann AG, Wiesbaden (Germany)

    2012-06-15

    The new E*LDS firmware E*COP{sup +} from Eckelmann AG (Wiesbaden, Federal Republic of Germany) for the optimization of the suction pressure supplies a demand-oriented adaptation of the suction pressure. The new feature is ideal for an update of existing systems with thermostatic expansion valves. Using this update operators of supermarket operators may save about 10% energy with little effort.

  1. Waste pipe calculus

    International Nuclear Information System (INIS)

    Kaufman, A.M.

    1978-01-01

    A rapid method is presented for calculating transport in a network of one-dimensional flow paths or ''pipes''. The method defines a Green's function for each flow path and prescribes a method of combining these Green's functions to produce an overall Green's function for the flow path network. A unique feature of the method is the use of the Laplace transform of these Green's functions to carry out most of the calculations

  2. Pipe damping studies

    International Nuclear Information System (INIS)

    Ware, A.G.

    1986-01-01

    The Idaho National Engineering Laboratory (INEL) is conducting a research program to assist the United States Nuclear Regulatory Commission (USNRC) in determining best-estimate damping values for use in the dynamic analysis of nuclear power plant piping systems. This paper describes four tasks in the program that were undertaken in FY-86. In the first task, tests were conducted on a 5-in. INEL laboratory piping system and data were analyzed from a 6-in. laboratory system at the ANCO Engineers facility to investigate the parameters influencing damping in the seismic frequency range. Further tests were conducted on 3- and 5-in. INEL laboratory piping systems as the second task to determine damping values representative of vibrations in the 33 to 100 Hz range, typical of hydrodynamic transients. In the third task a statistical evaluation of the available damping data was conduted to determine probability distributions suitable for use in probabilistic risk assessments (PRAs), and the final task evaluated damping data at high strain levels

  3. Pipe clamp effects on thin-walled pipe design

    International Nuclear Information System (INIS)

    Lindquist, M.R.

    1980-01-01

    Clamp induced stresses in FFTF piping are sufficiently large to require structural assessment. The basic principles and procedures used in analyzing FFTF piping at clamp support locations for compliance with ASME Code rules are given. Typical results from a three-dimensional shell finite element pipe model with clamp loads applied over the clamp/pipe contact area are shown. Analyses performed to categorize clamp induced piping loads as primary or secondary in nature are described. The ELCLAMP Computer Code, which performs analyses at clamp locations combining clamp induced stresses with stresses from overall piping system loads, is discussed. Grouping and enveloping methods to reduce the number of individual clamp locations requiring analysis are described

  4. Neurological Complications Related to Elective Orthopedic Surgery: Part 1: Common Shoulder and Elbow Procedures.

    Science.gov (United States)

    Dwyer, Tim; Henry, Patrick D G; Cholvisudhi, Phantila; Chan, Vincent W S; Theodoropoulos, John S; Brull, Richard

    2015-01-01

    Many anesthesiologists are unfamiliar with the rate of surgical neurological complications of the shoulder and elbow procedures for which they provide local anesthetic-based anesthesia and/or analgesia. Part 1 of this narrative review series on neurological complications of elective orthopedic surgery describes the mechanisms and likelihood of peripheral nerve injury associated with some of the most common shoulder and elbow procedures, including open and arthroscopic shoulder procedures, elbow arthroscopy, and total shoulder and elbow replacement. Despite the many articles available, the overall number of studied patients is relatively low. Large prospective trials are required to establish the true incidence of neurological complications following elective shoulder and elbow surgery. As the popularity of regional anesthesia increases with the development of ultrasound guidance, anesthesiologists should have a thoughtful understanding of the nerves at risk of surgical injury during elective shoulder and elbow procedures.

  5. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    Science.gov (United States)

    Pekkan, Kerem; Chang, Brian; Uslu, Fazil; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-07-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larvae (2500-20,000 μm total length) are reported using time-resolved microscopic particle image velocimetry. For the larval stages studied, the maximum peak suction velocity of the inflow bolus is measured at a finite distance from the mouth tip and ranges from 1 to 8 mm/s. The average pressure gradient and the velocity profile proximal to the buccal (mouth) cavity are calculated, and two distinct trends are identified. External recirculation regions and reverse flow feeding cycles are also observed and quantified. One of the unresolved questions in fish suction feeding is the shape and dynamics of the buccal cavity during suction feeding; optical coherence tomography imaging is found to be useful for reconstructing the mouth kinematics. The projected area of the mouth cavity during the feeding cycle varies up to 160 and 22 % for the transverse and mid-sagittal planes, respectively. These findings can inspire novel hydrodynamically efficient biomedical and microfluidic devices.

  6. Corner Separation Control by Boundary Layer Suction Applied to a Highly Loaded Axial Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Yangwei Liu

    2014-11-01

    Full Text Available Control of corner separation has attracted much interest due to its improvement of performance and energy utilization in turbomachinery. Numerical studies have been performed under both design and off-design flow conditions to investigate the effects of boundary layer suction (BLS on corner separation in a highly loaded compressor cascade. Two new BLS slot configurations are proposed and a total of five suction slot configurations were studied and compared. Averaged static pressure rise, exit loss coefficient, passage blockage and flow turning angle have been given and compared systematically over a range of operation incidence angles. Distributions of significant loss removal, blade loading, exit deviation and total pressure loss at 3 degree and 7 degree incidence have also been studied. Under the same suction mass flows of 0.7% of the inlet mass flows, the pitchwise suction slot on the endwall shows a better optimal performance over the whole operation incidence among single suction slots. By using of the new proposed compound slot configuration with one spanwise slot on the blade suction side and one pitchwise slot on the endwall, the maximum reduction of total pressure loss at 7 degree incidence can be 39.4%.

  7. Pipe inspection using the pipe crawler. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. In several of the buildings at the Fernald Site, there is piping that was used to transport process materials. As the demolition of these buildings occur, disposal of this piping has become a costly issue. Currently, all process piping is cut into ten-foot or less sections, the ends of the piping are wrapped and taped to prevent the release of any potential contaminants into the air, and the piping is placed in roll off boxes for eventual repackaging and shipment to the Nevada Test Site (NTS) for disposal. Alternatives that allow for the onsite disposal of process piping are greatly desired due to the potential for dramatic savings in current offsite disposal costs. No means is currently employed to allow for the adequate inspection of the interior of piping, and consequently, process piping has been assumed to be internally contaminated and thus routinely disposed of at NTS. The BTX-II system incorporates a high-resolution micro color camera with lightheads, cabling, a monitor, and a video recorder. The complete probe is capable of inspecting pipes with an internal diameter (ID) as small as 1.4 inches. By using readily interchangeable lightheads, the same system is capable of inspecting piping up to 24 inches in ID. The original development of the BTX system was for inspection of boiler tubes and small diameter pipes for build-up, pitting, and corrosion. However, the system is well suited for inspecting the interior of most types of piping and other small, confined areas. The report describes the technology, its performance, uses, cost, regulatory and policy issues, and lessons learned

  8. Heat pipes and heat pipe exchangers for heat recovery systems

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, L L; Grakovich, L P; Kiselev, V G; Kurustalev, D K; Matveev, Yu

    1984-01-01

    Heat pipes and heat pipe exchangers are of great importance in power engineering as a means of recovering waste heat of industrial enterprises, solar energy, geothermal waters and deep soil. Heat pipes are highly effective heat transfer units for transferring thermal energy over large distance (tens of meters) with low temperature drops. Their heat transfer characteristics and reliable working for more than 10-15 yr permit the design of new systems with higher heat engineering parameters.

  9. Pipe inspection using the pipe crawler. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. In several of the buildings at the Fernald Site, there is piping that was used to transport process materials. As the demolition of these buildings occur, disposal of this piping has become a costly issue. Currently, all process piping is cut into ten-foot or less sections, the ends of the piping are wrapped and taped to prevent the release of any potential contaminants into the air, and the piping is placed in roll off boxes for eventual repackaging and shipment to the Nevada Test Site (NTS) for disposal. Alternatives that allow for the onsite disposal of process piping are greatly desired due to the potential for dramatic savings in current offsite disposal costs. No means is currently employed to allow for the adequate inspection of the interior of piping, and consequently, process piping has been assumed to be internally contaminated and thus routinely disposed of at NTS. The BTX-II system incorporates a high-resolution micro color camera with lightheads, cabling, a monitor, and a video recorder. The complete probe is capable of inspecting pipes with an internal diameter (ID) as small as 1.4 inches. By using readily interchangeable lightheads, the same system is capable of inspecting piping up to 24 inches in ID. The original development of the BTX system was for inspection of boiler tubes and small diameter pipes for build-up, pitting, and corrosion. However, the system is well suited for inspecting the interior of most types of piping and other small, confined areas. The report describes the technology, its performance, uses, cost, regulatory and policy issues, and lessons learned.

  10. New Design of a Soft Robotics Wearable Elbow Exoskeleton Based on Shape Memory Alloy Wire Actuators

    OpenAIRE

    Copaci, Dorin; Cano, Enrique; Moreno, Luis; Blanco, Dolores

    2017-01-01

    The elbow joint is a complex articulation composed of the humeroulnar and humeroradial joints (for flexion-extension movement) and the proximal radioulnar articulation (for pronation-supination movement). During the flexion-extension movement of the elbow joint, the rotation center changes and this articulation cannot be truly represented as a simple hinge joint. The main goal of this project is to design and assemble a medical rehabilitation exoskeleton for the elbow with one degree of freed...

  11. Feasibility of four-dimensional preoperative simulation for elbow debridement arthroplasty.

    Science.gov (United States)

    Yamamoto, Michiro; Murakami, Yukimi; Iwatsuki, Katsuyuki; Kurimoto, Shigeru; Hirata, Hitoshi

    2016-04-02

    Recent advances in imaging modalities have enabled three-dimensional preoperative simulation. A four-dimensional preoperative simulation system would be useful for debridement arthroplasty of primary degenerative elbow osteoarthritis because it would be able to detect the impingement lesions. We developed a four-dimensional simulation system by adding the anatomical axis to the three-dimensional computed tomography scan data of the affected arm in one position. Eleven patients with primary degenerative elbow osteoarthritis were included. A "two rings" method was used to calculate the flexion-extension axis of the elbow by converting the surface of the trochlea and capitellum into two rings. A four-dimensional simulation movie was created and showed the optimal range of motion and the impingement area requiring excision. To evaluate the reliability of the flexion-extension axis, interobserver and intraobserver reliabilities regarding the assessment of bony overlap volumes were calculated twice for each patient by two authors. Patients were treated by open or arthroscopic debridement arthroplasties. Pre- and postoperative examinations included elbow range of motion measurement, and completion of the patient-rated questionnaire Hand20, Japanese Orthopaedic Association-Japan Elbow Society Elbow Function Score, and the Mayo Elbow Performance Score. Measurement of the bony overlap volume showed an intraobserver intraclass correlation coefficient of 0.93 and 0.90, and an interobserver intraclass correlation coefficient of 0.94. The mean elbow flexion-extension arc significantly improved from 101° to 125°. The mean Hand20 score significantly improved from 52 to 22. The mean Japanese Orthopaedic Association-Japan Elbow Society Elbow Function Score significantly improved from 67 to 88. The mean Mayo Elbow Performance Score significantly improved from 71 to 91 at the final follow-up evaluation. We showed that four-dimensional, preoperative simulation can be generated by

  12. Does Excision of Heterotopic Ossification of the Elbow Result in Satisfactory Patient-Rated Outcomes?

    Science.gov (United States)

    Sandeep, K N; Suresh, G; Gopisankar, B; Abhishek, N; Sujiv, A

    2017-03-01

    Treatment of heterotopic ossification (HO) of the elbow is challenging and fraught with complications. Patients who sustain direct trauma to the elbow joint, the central nervous system, and thermal burns are at increased risk for development of HO. There is a paucity of studies and reports on patient's self-evaluation after the excision of the heterotopic ossification. This retrospective study assessed outcomes after excision of heterotopic ossification around the elbow in a cohort of ten patients operated from 2012 to 2015. The outcome assessment was done by the Mayo Elbow Performance index (MEPI) and the American Shoulder and Elbow Surgeons-Elbow score (ASES-E scores). The mean follow-up was 18.11 months after the operation. The Mayo Elbow Performance Score was excellent in two elbows, good in six and fair in two. The mean gain in flexion-extension arc after excision of HO was 80 degrees. All of the patients had residual flexion deformity postoperatively. Eight of the nine patients were able to do activities requiring flexion at final follow-up. Excision of HO around the elbow is associated with satisfactory patient-rated outcomes in spite of failure to regain full range of motion.

  13. Muscle contributions to elbow joint rotational stiffness in preparation for sudden external arm perturbations.

    Science.gov (United States)

    Holmes, Michael W R; Keir, Peter J

    2014-04-01

    Understanding joint stiffness and stability is beneficial for assessing injury risk. The purpose of this study was to examine joint rotational stiffness for individual muscles contributing to elbow joint stability. Fifteen male participants maintained combinations of three body orientations (standing, supine, sitting) and three hand preloads (no load, solid tube, fluid filled tube) while a device imposed a sudden elbow extension. Elbow angle and activity from nine muscles were inputs to a biomechanical model to determine relative contributions to elbow joint rotational stiffness, reported as percent of total stiffness. A body orientation by preload interaction was evident for most muscles (Psafety.

  14. Correlation of radiographic, necropsy and histologic findings in 8 dogs with elbow dysplasia

    International Nuclear Information System (INIS)

    Keller, G.G.; Kreeger, J.M.; Mann, F.A.; Lattimer, J.C.

    1997-01-01

    Elbow dysplasia is osteoarthrosis/degenerative joint disease due to abnormal development of the elbow joint. The abnormal development is the result of specific inherited etiologies alone or in combination. This paper attempts to clarify the diagnosis of elbow dysplasia based on the presence of degenerative joint disease by correlating radiographic, necropsy, and histopathologic results using elbows from 8 German Shepherd dogs. All elbows had radiographic changes consistent with osteoarthrosis/degenerative joint disease which were identified best on the flexed medial-lateral projection. Radiographically, a specific diagnosis was made in seven elbows; ununited anconeal process (6) and osteochondrosis (1). At necropsy these lesions were confirmed plus 14 elbows were identified that had fragmented medial coronoid process (6), abnormally shaped medial coronoid processes or fissures in the articular cartilage of the medial coronoid process (8). Additionally, histopathologically there was proliferative synovitis at the radial notch of the ulna and degenerative changes on the proximal, nonarticular surface of the anconeal process at the site of insertion of the olecranon ligament and joint capsule. Therefore, for screening the elbow joint to identify elbow dysplasia, the recognition of osteoarthrosis/degenerative joint disease on an extreme flexed mediolateral radiograph appears to be sufficient

  15. Effect of cryotherapy after elbow arthrolysis: a prospective, single-blinded, randomized controlled study.

    Science.gov (United States)

    Yu, Shi-yang; Chen, Shuai; Yan, He-de; Fan, Cun-yi

    2015-01-01

    To investigate the effect of cryotherapy after elbow arthrolysis on elbow pain, blood loss, analgesic consumption, range of motion, and long-term elbow function. Prospective, single-blinded, randomized controlled study. University hospital. Patients (N=59; 27 women, 32 men) who received elbow arthrolysis. Patients were randomly assigned into a cryotherapy group (n=31, cryotherapy plus standard care) or a control group (n=28, standard care). Elbow pain at rest and in motion were measured using a visual analog scale (VAS) on postoperative day (POD) 1 to POD 7 and at 2 weeks and 3 months after surgery. Blood loss and analgesic consumption were recorded postoperatively. Elbow range of motion (ROM) was measured before surgery and on POD 1, POD 7, and 3 months after surgery. The Mayo Elbow Performance Score (MEPS) was evaluated preoperatively and 3 months postoperatively. VAS scores were significantly lower in the cryotherapy group during the first 7 PODs, both at rest and in motion (Pcryotherapy group than the control group for pain relief (P.05). Cryotherapy is effective in relieving pain and reducing analgesic consumption for patients received elbow arthrolysis. The application of cryotherapy will not affect blood loss, ROM, or elbow function. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Pipe support program at Pickering

    International Nuclear Information System (INIS)

    Sahazizian, L.A.; Jazic, Z.

    1997-01-01

    This paper describes the pipe support program at Pickering. The program addresses the highest priority in operating nuclear generating stations, safety. We present the need: safety, the process: managed and strategic, and the result: assurance of critical piping integrity. In the past, surveillance programs periodically inspected some systems, equipment, and individual components. This comprehensive program is based on a managed process that assesses risk to identify critical piping systems and supports and to develop a strategy for surveillance and maintenance. The strategy addresses all critical piping supports. Successful implementation of the program has provided assurance of critical piping and support integrity and has contributed to decreasing probability of pipe failure, reducing risk to worker and public safety, improving configuration management, and reducing probability of production losses. (author)

  17. The effects of gender, level of co-contraction, and initial angle on elbow extensor muscle stiffness and damping under a step increase in elbow flexion moment.

    Science.gov (United States)

    Lee, Yunju; Ashton-Miller, James A

    2011-10-01

    Flexion buckling of an arm under the large ground reaction loads associated with arresting a fall to the ground increases the risk for head and thorax injuries. Yet, the factors that determine the arm buckling load remain poorly understood. We tested the hypothesis in 18 healthy young adults that neither gender, triceps co-contraction level (i.e., 25, 50, or 75% MVC) nor elbow angle would affect the rotational stiffness and damping resistance to step changes in elbow flexion loading. Data on the step response were gathered using optoelectronic markers (150 Hz) and myoelectric activity measurements (2 kHz), and an inverse dynamics analysis was used to estimate elbow extensor stiffness and damping coefficients. A repeated-measures analysis of variance showed that gender (p = 0.032), elbow flexion angle and co-contraction level (both p initial elbow flexion angle and maximum co-contraction, female stiffness and damping coefficients were 18 and 30% less, respectively, than male values after normalization by body height and weight. We conclude that the maximum extensor rotational stiffness and damping at the elbow is lower in women than in men of the same body size, and varies with triceps co-contraction level and initial elbow angle.

  18. Rekonstruksi pada Perforasi Palatum Akibat Pneggunaan Gigi Tiruan Lengkap Rahang Atas dengan Suction Cup

    Directory of Open Access Journals (Sweden)

    Cristiani Nadya Pramasari

    2012-12-01

    Full Text Available Latar belakang. Pemasangan suction cup pada gigi tiruan lengkap rahang atas merupakan salah satu cara untuk meningkatkan referensi. Kondisi vakum oleh karena suction cup ini dalam waktu jangka panjang dan tidak terkontrol mengakibatkan nekrosis jaringan yaitu adanya perforasi palatum. Tujuan. Melaporkan rekonstruksi penutupan perforasi palatum sebagai komplikasi penggunaan gigi tiruan lengkap rahang atas dengan suction cup. Laporan Kasus. Pada tanggal 11 September 2012 seorang pria berusia 64 tahun datang ke Poliklinik Bedah Mulut RSUP dr. Sardjito Yogyakarta dengan keluhan terdapat lubang pada langit-langit. Pasien menggunakan gigi palsu buatan tukang gigi dengan perekat berbahan karet pada langit-langit selama 5 tahun. Selama penggunaan gigi palsu pasien sering mengalami sakit dan pembengkakan di langit-langit sampai keluar nanah dan akhirnya terbentuk lubang sehingga jika minum air keluar dari hidung. Pemeriksaan rontgen oklusal rahang atas tampak adanya resorbsi regio palatum durum. Rekonstruksi menggunakan teknik push back modifikasi dilakukan untuk penutupan perforasi palatum di bawah anestesi umum. Kesimpulan. Suction cup pada gigi tiruan lengkap rahang atas mengakibatkan kerusakan jaringan lunak dan jaringan keras rongga mulut. Perforasi palatum yang diakibatkan oleh suction cup ini dapat dilakukan rekonstruksi dengan teknik push back dengan hasil yang cukup optimal.   Background. Suction cups are used to get retention of the complete dentures. The uncontrolled constant vacuum created by the suction cup induces necrosis of tissues and perforation ofpalate. Objective. To report reconstruction for palatal perforation closure as a complication due to prolonged use of maxillary denture with suction cup. Case Report. A 64 years old male patient came to the Department of Oral Surgery, Sardjito General Hospital Yogyakarta on September 11, 2012 with the complaint of hole in his palate. He was wearing dentures for the past 5 years. He also

  19. Damping in LMFBR pipe systems

    International Nuclear Information System (INIS)

    Anderson, M.J.; Barta, D.A.; Lindquist, M.R.; Renkey, E.J.; Ryan, J.A.

    1983-06-01

    LMFBR pipe systems typically utilize a thicker insulation package than that used on water plant pipe systems. They are supported with special insulated pipe clamps. Mechanical snubbers are employed to resist seismic loads. Recent laboratory testing has indicated that these features provide significantly more damping than presently allowed by Regulatory Guide 1.61 for water plant pipe systems. This paper presents results of additional in-situ vibration tests conducted on FFTF pipe systems. Pipe damping values obtained at various excitation levels are presented. Effects of filtering data to provide damping values at discrete frequencies and the alternate use of a single equivalent modal damping value are discussed. These tests further confirm that damping in typical LMFBR pipe systems is larger than presently used in pipe design. Although some increase in damping occurred with increased excitation amplitude, the effect was not significant. Recommendations are made to use an increased damping value for both the OBE and DBE seismic events in design of LMFBR pipe systems

  20. Dynamic experiments on cracked pipes

    International Nuclear Information System (INIS)

    Petit, M.; Brunet, G.; Buland, P.

    1991-01-01

    In order to apply the leak before break concept to piping systems, the behavior of cracked pipes under dynamic, and especially seismic loading must be studied. In a first phase, an experimental program on cracked stainless steel pipes under quasi-static monotonic loading has been conducted. In this paper, the dynamic tests on the same pipe geometry are described. These tests have been performed on a shaking table with a mono frequency input signal. The main parameter of the tests is the frequency of excitation versus the frequency of the system

  1. Water hammer in elastic pipes

    International Nuclear Information System (INIS)

    Gale, J.; Tiselj, I.

    2002-01-01

    One dimensional two-fluid six-equation model of two-phase flow, that can be found in computer codes like RELAP5, TRAC, and CATHARE, was upgraded with additional terms, which enable modelling of the pressure waves in elastic pipes. It is known that pipe elasticity reduces the propagation velocity of the shock and other pressure waves in the piping systems. Equations that include the pipe elasticty terms are used in WAHA code, which is being developed within the WAHALoads project of 5't'h EU research program.(author)

  2. Structural evaluation report of piping and support structure for design-changed hot-water layer system

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo

    1998-05-01

    After hot-water layer system had been installed, the verification tests to reduce the radiation level at the top of reactor pool were performed many times. The major goal of this report is to assess the structural integrity on the piping and the support structures of design-changed hot-water layer system. The piping stress analysis was performed by using ADLPIPE program for the pump suction line and the pump discharge line subjected to dead weight, pressure, thermal expansion and seismic loadings. The stress analysis of the support structure was carried out using the reaction forces obtained from the piping stress analysis. The results of structural evaluation for the pipings and the support structures showed that the structural acceptance criteria were satisfied, in compliance with ASME, subsection ND for the piping and subsection NF for the support structures. Therefore based on the results of the analysis and the design, the structural integrity on the piping and the support structures of design-changed hot-water system was proved. (author). 9 refs., 9 tabs., 14 figs

  3. Progress report on a NDT round robin on austenitic circumferential pipe welds

    International Nuclear Information System (INIS)

    Brast, G.; Maier, H.J.; Knoch, P.; Mletzko, U.

    1998-01-01

    The objective of the project is establish on the basis of Round Robin tests the current state of efficiency of various, defined testing methods, so that required or achievable optimizations can be defined and made. The project work up to date encompasses mon-destructive examinations of 15 austenitic welds with nominal widths DN 150/200/250 and wall thicknesses from 8 to 18 mm. Except for one test piece, (elbow/elbow), the joining welds are straight pipe to elbow welds. The results of the Round Robin tests show that the NDE detection limits for the fault examined (intercrystalline stress corrosion cracking) are in the range assumed so far, i.e. from about 20 to 25% of the wall thickness to be examined. The defect detection rates of the ultrasonic test methods applied are approx. 70% and thus are about equal in achievement with comparable international Round Robin tests (PISC; ASME/PDI, ENIQ, etc.). Clearly better are the fault detection rates of radiography. Evaluation of the individual results indicates the detection limits can be improved, by 1. reducing the misalignment of edges, 2. grinding of welds, 3. avoiding sharp notches at the root, 4. producing coaxial surfaces. (orig./CB) [de

  4. Development of Energy Efficiency Design Map based on acoustic resonance frequency of suction muffler in compressor

    International Nuclear Information System (INIS)

    Oh, Seungjae; Wang, Semyung; Cho, Sungman

    2015-01-01

    Highlights: • Development of Energy Efficiency Design Map. • Experimental validation of Energy Efficiency Design Map. • Suggestion regarding the Acoustically Supercharged Energy Efficiency. • Sensitivity analysis of the Energy Efficiency Ratio with respect to acoustic pressure. • Suggestion regarding the hybrid coupling method for acoustic analysis in compressor. - Abstract: The volumetric efficiency of the Internal Combustion (IC) engine and compressor can be increased by properly adjusting the acoustic resonance frequency of the suction muffler or the suction valve timing without any additional equipment or power source. This effect is known as acoustic supercharging. However, the energy efficiency has become more important than the volumetric efficiency because of the energy shortage issue and factors influencing consumers’ purchasing decisions. Therefore, methods for increasing the energy efficiency using the acoustic effect in the suction part of IC engine and compressor should be considered. In this study, a systematic method for improving the energy efficiency using the acoustic effect in the suction part of the compressor used in refrigerators and air conditioners was developed for the first time. This effect is named as the Acoustically Supercharged Energy Efficiency (ASEE). For the ASEE, first, a hybrid coupling method was suggested for the acoustical analysis in the suction part of the compressor. Next, an Energy Efficiency Design Map (EEDM) was proposed. This can serve as a design guide for suction mufflers in terms of the energy efficiency. Finally, sensitivity analyses of the Energy Efficiency Ratio (EER) and total massflow rate with respect to the acoustic pressure were conducted to identify the relationship between the acoustic pressure and the suction valve motion. This provides the physical background for the EEDM

  5. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    Science.gov (United States)

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  6. Decreased Brain Neurokinin-1 Receptor Availability in Chronic Tennis Elbow.

    Science.gov (United States)

    Linnman, Clas; Catana, Ciprian; Svärdsudd, Kurt; Appel, Lieuwe; Engler, Henry; Långström, Bengt; Sörensen, Jens; Furmark, Tomas; Fredrikson, Mats; Borsook, David; Peterson, Magnus

    Substance P is released in painful and inflammatory conditions, affecting both peripheral processes and the central nervous system neurokinin 1 (NK1) receptor. There is a paucity of data on human brain alterations in NK1 expression, how this system may be affected by treatment, and interactions between central and peripheral tissue alterations. Ten subjects with chronic tennis elbow (lateral epicondylosis) were selected out of a larger (n = 120) randomized controlled trial evaluating graded exercise as a treatment for chronic tennis elbow (lateral epicondylosis). These ten subjects were examined by positron emission tomography (PET) with the NK1-specific radioligand 11C-GR205171 before, and eight patients were followed up after treatment with graded exercise. Brain binding in the ten patients before treatment, reflecting NK1-receptor availability (NK1-RA), was compared to that of 18 healthy subjects and, longitudinally, to the eight of the original ten patients that agreed to a second PET examination after treatment. Before treatment, patients had significantly lower NK1-RA in the insula, vmPFC, postcentral gyrus, anterior cingulate, caudate, putamen, amygdala and the midbrain but not the thalamus and cerebellum, with the largest difference in the insula contralateral to the injured elbow. No significant correlations between brain NK1-RA and pain, functional severity, or peripheral NK1-RA in the affected limb were observed. In the eight patients examined after treatment, pain ratings decreased in everyone, but there were no significant changes in NK1-RA. These findings indicate a role for the substance P (SP) / NK1 receptor system in musculoskeletal pain and tissue healing. As neither clinical parameters nor successful treatment response was reflected in brain NK1-RA after treatment, this may reflect the diverse function of the SP/NK1 system in CNS and peripheral tissue, or a change too small or slow to capture over the three-month treatment.

  7. Management of Tennis Elbow with sodium hyaluronate periarticular injections

    Directory of Open Access Journals (Sweden)

    Petrella Robert J

    2010-02-01

    Full Text Available Abstract Objectives To determine the efficacy and safety of peri-articular hyaluronic acid injections in chronic lateral epicondylosis (tennis elbow. Design Prospective randomized clinical trial in primary care sport medicine. Patients Three hundred and thirty one consecutive competitive racquette sport athletes with chronic (>3 months lateral epicondylosis were administered 2 injections (first injection at baseline into the subcutaneous tissue and muscle 1 cm. from the lateral epicondyle toward the primary point of pain using a two-dimensional fanning technique. A second injection was administered 1 week later. Outcomes measures Assessments were done at baseline, days 7, 14, 30, 90 and 356. Efficacy measures included patient's visual analogue scale (VAS of pain at rest (0-100 mm and following assessment of grip strength (0-100 mm. Grip strength was determined using a jamar hydraulic hand dynamometer. Other assessments included patients' global assessment of elbow injury (5 point categorical scale; 1 = no disability, 5 = maximal disability, patients' assessment of normal function/activity (5 point categorical scale, patients/physician satisfaction assessment (10 point categorical scale, time to return to pain-free and disability-free sport and adverse events as per WHO definition. Differences between groups were determined using an intent-to-treat ANOVA. Results Average age of the study population was 49 years (± 12 years. One hundred and sixty-five patients were randomized to the HA and 166 were randomized to the control groups. The change in VAS pain was -6.7 (± 2.0 for HA vs -1.3 (± 1.5 for control (p Conclusion Peri-articular HA treatment for tennis elbow was significantly better than control in improving pain at rest and after maximal grip testing. Further, HA treatment was highly satisfactory by patients and physicians and resulted in better return to pain free sport compared to control.

  8. Decreased Brain Neurokinin-1 Receptor Availability in Chronic Tennis Elbow.

    Directory of Open Access Journals (Sweden)

    Clas Linnman

    Full Text Available Substance P is released in painful and inflammatory conditions, affecting both peripheral processes and the central nervous system neurokinin 1 (NK1 receptor. There is a paucity of data on human brain alterations in NK1 expression, how this system may be affected by treatment, and interactions between central and peripheral tissue alterations. Ten subjects with chronic tennis elbow (lateral epicondylosis were selected out of a larger (n = 120 randomized controlled trial evaluating graded exercise as a treatment for chronic tennis elbow (lateral epicondylosis. These ten subjects were examined by positron emission tomography (PET with the NK1-specific radioligand 11C-GR205171 before, and eight patients were followed up after treatment with graded exercise. Brain binding in the ten patients before treatment, reflecting NK1-receptor availability (NK1-RA, was compared to that of 18 healthy subjects and, longitudinally, to the eight of the original ten patients that agreed to a second PET examination after treatment. Before treatment, patients had significantly lower NK1-RA in the insula, vmPFC, postcentral gyrus, anterior cingulate, caudate, putamen, amygdala and the midbrain but not the thalamus and cerebellum, with the largest difference in the insula contralateral to the injured elbow. No significant correlations between brain NK1-RA and pain, functional severity, or peripheral NK1-RA in the affected limb were observed. In the eight patients examined after treatment, pain ratings decreased in everyone, but there were no significant changes in NK1-RA. These findings indicate a role for the substance P (SP / NK1 receptor system in musculoskeletal pain and tissue healing. As neither clinical parameters nor successful treatment response was reflected in brain NK1-RA after treatment, this may reflect the diverse function of the SP/NK1 system in CNS and peripheral tissue, or a change too small or slow to capture over the three-month treatment.

  9. Plastics pipe couplings

    International Nuclear Information System (INIS)

    Glover, J.B.

    1980-07-01

    A method is described of making a pipe coupling of the type comprising a plastics socket and a resilient annular sealing member secured in the mouth thereof, in which the material of at least one component of the coupling is subjected to irradiation with high energy radiation whereby the material is caused to undergo cross-linking. As examples, the coupling may comprise a polyethylene or plasticised PVC socket the material of which is subjected to irradiation, and the sealing member may be moulded from a thermoplastic elastomer which is subjected to irradiation. (U.K.)

  10. Pediatric elbow fractures: a new angle on an old topic

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Kathleen H.; Anton, Christopher G. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Zingula, Shannon N. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Salisbury, Shelia R. [Cincinnati Children' s Hospital Medical Center, Biostatistics and Epidemiology, Cincinnati, OH (United States); Tamai, Junichi [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Orthopedics, Cincinnati, OH (United States)

    2016-01-15

    The three most common elbow fractures classically reported in pediatric orthopedic literature are supracondylar (50-70%), lateral condylar (17-34%), and medial epicondylar fractures (10%), with fractures of the proximal radius (including but not limited to fractures of the radial neck) being relatively uncommon (5-10%). Our experience at a large children's hospital suggests a different distribution. Our goals were (1) to ascertain the frequency of different elbow fracture types in a large pediatric population, and (2) to determine which fracture types were occult on initial radiographs but detected on follow-up. Review of medical records identified 462 children, median age 6 years and interquartile range for age of 4-8 years (range 0.8-18 years), who were diagnosed with elbow fractures at our institution over a 10-month period. Initial and follow-up radiographs were reviewed in blinded fashion independently by two experienced pediatric musculoskeletal radiologists to identify fracture types on initial and follow-up radiographs. The most common fractures included supracondylar (n = 258, 56%), radial neck (n = 80, 17%), and lateral condylar (n = 69, 15%). Additional fractures were seen on follow-up exams in 32 children. Of these, 25 had a different fracture type than was identified on initial radiographs. The most common follow-up fractures were olecranon (n = 23, 72%), coronoid process (n = 4, 13%) and supracondylar (n = 3, 9%). Olecranon fractures were significantly more common on follow-up radiographs than they were on initial radiographs (n = 33, 7%; P <.0001). Twenty-six children had more than one fracture type on the initial radiograph. The most common fracture combinations were radial neck with olecranon (n = 9) and supracondylar with lateral condylar (n = 9). Supracondylar fractures are the most frequent elbow fracture seen initially, followed by radial neck, lateral condylar, and olecranon fractures in a distribution different from what has been

  11. Kinetic chain contributions to elbow function and dysfunction in sports.

    Science.gov (United States)

    Ben Kibler, W; Sciascia, Aaron

    2004-10-01

    The elbow functions in throwing and other athletic activities as a link in the kinetic chain of force development, regulation, and transfer. Efficient function, with maximal performance and minimal injury risk, requires optimum activation of all the link in the kinetic chain. Injury is often associated with alterations in force production or regulation capabilities in links that may be distant to the site of injury. Evaluation of injured athletes should include screening examinations for these areas, and treatment and conditioning should also include these areas.

  12. Hemophilic osteoarthropathy with special attention to the elbow joint

    International Nuclear Information System (INIS)

    Erlemann, R.; Adolph, J.; Peters, P.E.; Pollmann, H.

    1990-01-01

    Hemophilia is a rare disorder, whereas recurrent bleedings in the joint can result in osteoarthropathy. Radiological changes consist of osteoporosis, enlargement of the epiphyses, irregularity of the subchondral bone surface, narrowing of the joint space, cysts, erosions, joint incongruence and joint deformity. The earlier and the more frequently bleedings have occurred which have not been treated adequately, the more of the changes mentioned above are present. In children, osteoarthropathy of the elbow is present in only about 50% of cases, and in the remaining cases the degree is mostly minimal or moderate. Differential diagnosis consists of juvenile rheumatoid arthritis in children, and rheumatoid arthritis and osteoarthritis in adults. (orig.) [de

  13. Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation

    Directory of Open Access Journals (Sweden)

    Tze Hui Koh

    2017-10-01

    Full Text Available The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii an intent-based actuation, in which user intent is detected by surface electromyography (sEMG sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed.

  14. Large-bore pipe decontamination

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1998-01-01

    The decontamination and decommissioning (D and D) of 1200 buildings within the US Department of Energy-Office of Environmental Management (DOE-EM) Complex will require the disposition of miles of pipe. The disposition of large-bore pipe, in particular, presents difficulties in the area of decontamination and characterization. The pipe is potentially contaminated internally as well as externally. This situation requires a system capable of decontaminating and characterizing both the inside and outside of the pipe. Current decontamination and characterization systems are not designed for application to this geometry, making the direct disposal of piping systems necessary in many cases. The pipe often creates voids in the disposal cell, which requires the pipe to be cut in half or filled with a grout material. These methods are labor intensive and costly to perform on large volumes of pipe. Direct disposal does not take advantage of recycling, which could provide monetary dividends. To facilitate the decontamination and characterization of large-bore piping and thereby reduce the volume of piping required for disposal, a detailed analysis will be conducted to document the pipe remediation problem set; determine potential technologies to solve this remediation problem set; design and laboratory test potential decontamination and characterization technologies; fabricate a prototype system; provide a cost-benefit analysis of the proposed system; and transfer the technology to industry. This report summarizes the activities performed during fiscal year 1997 and describes the planned activities for fiscal year 1998. Accomplishments for FY97 include the development of the applicable and relevant and appropriate regulations, the screening of decontamination and characterization technologies, and the selection and initial design of the decontamination system

  15. Heat pipe and method of production of a heat pipe

    International Nuclear Information System (INIS)

    Kemp, R.S.

    1975-01-01

    The heat pipe consists of a copper pipe in which a capillary network or wick of heat-conducting material is arranged in direct contact with the pipe along its whole length. Furthermore, the interior space of the tube contains an evaporable liquid for pipe transfer. If water is used, the capillary network consists of, e.g., a phosphorus band network. To avoid contamination of the interior of the heat pipe during sealing, its ends are closed by mechanical deformation so that an arched or plane surface is obtained which is in direct contact with the network. After evacuation of the interior space, the remaining opening is closed with a tapered pin. The ratio wall thickness/tube diameter is between 0.01 and 0.6. (TK/AK) [de

  16. Pilot Study Comparing Closed Versus Open Tracheal Suctioning in Postoperative Neonates and Infants With Complex Congenital Heart Disease.

    Science.gov (United States)

    Tume, Lyvonne N; Baines, Paul B; Guerrero, Rafael; Hurley, Margaret A; Johnson, Robert; Kalantre, Atul; Ramaraj, Ram; Ritson, Paul C; Walsh, Laura; Arnold, Philip D

    2017-07-01

    To determine the hemodynamic effect of tracheal suction method in the first 36 hours after high-risk infant heart surgery on the PICU and to compare open and closed suctioning techniques. Pilot randomized crossover study. Single PICU in United Kingdom. Infants undergoing surgical palliation with Norwood Sano, modified Blalock-Taussig shunt, or pulmonary artery banding in the first 36 hours postoperatively. Infants were randomized to receive open or closed (in-line) tracheal suctioning either for their first or second study tracheal suction in the first 36 hours postoperatively. Twenty-four infants were enrolled over 18 months, 11 after modified Blalock-Taussig shunt, seven after Norwood Sano, and six after pulmonary artery banding. Thirteen patients received the open suction method first followed by the closed suction method second, and 11 patients received the closed suction method first followed by the open suction method second in the first 36 hours after their surgery. There were statistically significant larger changes in heart rate (p = 0.002), systolic blood pressure (p = 0.022), diastolic blood pressure (p = 0.009), mean blood pressure (p = 0.007), and arterial saturation (p = 0.040) using the open suction method, compared with closed suctioning, although none were clinically significant (defined as requiring any intervention). There were no clinically significant differences between closed and open tracheal suction methods; however, there were statistically significant greater changes in some hemodynamic variables with open tracheal suctioning, suggesting that closed technique may be safer in children with more precarious physiology.

  17. Impact analyses after pipe rupture

    International Nuclear Information System (INIS)

    Chun, R.C.; Chuang, T.Y.

    1983-01-01

    Two of the French pipe whip experiments are reproduced with the computer code WIPS. The WIPS results are in good agreement with the experimental data and the French computer code TEDEL. This justifies the use of its pipe element in conjunction with its U-bar element in a simplified method of impact analyses

  18. Mechanical Behaviour of Lined Pipe

    NARCIS (Netherlands)

    Hilberink, A.

    2011-01-01

    Installing lined pipe by means of the reeling installation method seems to be an attractive combination, because it provides the opportunity of eliminating the demanding welds from the critical time offshore and instead preparing them onshore. However, reeling of lined pipe is not yet proven

  19. Pulsed TIG welding of pipes

    International Nuclear Information System (INIS)

    Killing, U.

    1989-01-01

    The present study investigates into the effects of impulse welding parameters on weld geometry in the joint welding of thin-walled sheets and pipes (d=2.5 mm), and it uses random samples of thick-walled sheets and pipes (d=10 mm), in fixed positions. (orig./MM) [de

  20. Vortex lift augmentation by suction on a 60 deg swept Gothic wing

    Science.gov (United States)

    Taylor, A. H.; Jackson, L. R.; Huffman, J. K.

    1982-01-01

    An experimental investigation was conducted in the Langley high-speed 7- by 10-foot wind tunnel to determine the aerodynamic performance of suction applied near the wing tips above the trailing edge of a 60 deg swept Gothic wing. Moveable suction inlets were symmetrically mounted in the proximity of the trailing edge, and the amount of suction was varied to maximize wing lift. Tests were conducted at Mach 0.15, 0.30, and 0.45, and the angle of attack was varied from -4 to 50 deg. The suction augmentation increases the lift coefficient over the entire range of angle of attack. The lift improvement exceeds the unaugmented wing lift by over 20%. Moreover, the augmented lift exceeds the lift predicted by vortex lattice theory to 30 deg angle of attack. Suction augmentation is postulated to strengthen the vortex system by increasing its velocity and making it more concentrated. This causes the vortex breakdown to be delayed to a higher angle of attack