WorldWideScience

Sample records for efficient cad system

  1. Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.

    Science.gov (United States)

    Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung

    2015-12-01

    The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic

  2. Structural design by CAD system

    International Nuclear Information System (INIS)

    Kim, Jhin Wung; Shim, Jae Ku; Kim, Sun Hoon; Kim, Dae Hong; Lee, Kyung Jin; Choi, Kyu Sup; Choi, In Kil; Lee, Dong Yong

    1988-12-01

    CAD systems are now widely used for the design of many engineering problems involving static, dynamic and thermal stress analyses of structures. In order to apply CAD systems to the structural analysis and design, the function of hardwares and softwares necessary for the CAD systems must be understood. The purpose of this study is to introduce the basic elements that are indispensible in the application of CAD systems to the analysis and design of structures and to give a thorough understanding of CAD systems to design engineers, so as to participate in the further technological developments of CAD systems. Due to the complexity and variety of the shape and size of the nowa-days structures, the need of new design technologies is growing for more efficient, accurate and economical design of structures. The application of CAD systems to structural engineering fields enables to improve structural engineering analysis and design technologies and also to obtain the standardization of the design process. An active introduction of rapidly developing CAD technologies will contribute to analyzing and designing structures more efficiently and reliably. Based on this report of the current status of the application of CAD systems to the structural analysis and design, the next goal is to develop the expert system which enables to perform the design of structures by CAD systems from the preliminary conceptual design to the final detail drawings automatically. (Author)

  3. TGeoCad: an Interface between ROOT and CAD Systems

    International Nuclear Information System (INIS)

    Luzzi, C; Carminati, F

    2014-01-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems

  4. TGeoCad: an Interface between ROOT and CAD Systems

    Science.gov (United States)

    Luzzi, C.; Carminati, F.

    2014-06-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems.

  5. A CAD model for energy efficient offshore structures for desalination and energy generation

    Directory of Open Access Journals (Sweden)

    R. Rahul Dev,

    2016-09-01

    Full Text Available This paper presents a ‘Computer Aided Design (CAD’ model for energy efficient design of offshore structures. In the CAD model preliminary dimensions and geometric details of an offshore structure (i.e. semi-submersible are optimized to achieve a favorable range of motion to reduce the energy consumed by the ‘Dynamic Position System (DPS’. The presented model allows the designer to select the configuration satisfying the user requirements and integration of Computer Aided Design (CAD and Computational Fluid Dynamics (CFD. The integration of CAD with CFD computes a hydrodynamically and energy efficient hull form. Our results show that the implementation of the present model results into an design that can serve the user specified requirements with less cost and energy consumption.

  6. Building of a CAD system for I and C system of nuclear power plant

    International Nuclear Information System (INIS)

    Ma Zhicai; Zhang Dongsheng

    2013-01-01

    An I and C database was developed based on the design objects and properties presented in I and C design documents of nuclear power plant. With the database, a rapid-implemented CAD system for I and C engineering was designed and implemented with popular CAD software, AutoCAD and Visio, and desktop database management system, Access, to manage the design data and to automate the composing task for listings, forms and drawings. This system was applied in an engineering project for data management, document generation and drawing aid, and demonstrated its usability and efficiency. (authors)

  7. Sophistication and integration of plant engineering CAD-CAE systems

    International Nuclear Information System (INIS)

    Yoshinaga, Toshiaki; Hanyu, Masaharu; Ota, Yoshimi; Kobayashi, Yasuhiro.

    1995-01-01

    In respective departments in charge of basic planning, design, manufacture, inspection and construction of nuclear power plants, by the positive utilization of CAD/CAE system, efficient workings have been advanced. This time, the plant integrated CAE system wich heightens the function of these individual systems, and can make workings efficient and advanced by unifying and integrating them was developed. This system is composed of the newly developed application system and the data base system which enables the unified management of engineering data and high speed data conversion in addition to the CAD system for three-dimensional plant layout planning. On the basis of the rich experience and the proposal of improvement of designers by the application of the CAD system for three-dimensional plant layout planning to actual machines, the automation, speed increase and the visualization of input and output by graphical user interface (GUI) in the processing of respective applications were made feasible. As the advancement of plant CAE system, scenic engineering system, integrated layout CAE system, electric instrumentation design CAE system and construction planning CAE system are described. As for the integration of plant CAE systems, the integrated engineering data base, the combination of plant CAE systems, and the operation management in the dispersed environment of networks are reported. At present, Hitachi Ltd. exerts efforts for the construction of atomic energy product in formation integrated management system as the second stage of integration. (K.I.)

  8. Development of new CAD system for steel structures of nuclear power plants

    International Nuclear Information System (INIS)

    Morii, Yasuhiro; Kudou, Takashi; Kouno, Kenichi; Yamada, Koutarou

    2000-01-01

    IHI has developed a new Three-Dimensional Computer-Aided Design (3D-CAD) system to improve the design efficiency and quality of the steel structure of nuclear power plants. This system covers every design phase from the initial arrangement of structure to the production design sharing the same database. The system incorporates the design rules and professional expertise of designers, and enable easy and efficient design. The system can easily generate the three-dimensional data for structures, model data for stress analyses and composite arrangement data. The system has already been applied to several plants under construction and has achieved excellent results. The outline of the new CAD system is introduced. (author)

  9. Customizing CAD system and its application for engineering design

    International Nuclear Information System (INIS)

    Shin, Jeong Ho; Kwak, Byung Man

    2003-01-01

    The computer is an important tool to design an engineering system and CAD systems are widely used for various design practice. To meet the market requirements, the old mass production system is being changed into the mass customization system. As for CAD systems, it is increasingly required to extend, automate, and customize a wide range of functionality. This article describes the state-of-the-art of the principal technologies for customizing CAD systems. And we have implemented an application that enables the parametric design by directly inputting numerical values of parameters for a CAD model. Based on this application, we have developed another system that makes it possible sharing of part family data between SolidEdge and Pro/Engineer. Through customization of CAD systems, it is possible to improve the product quality using external knowledge-based systems or to integrate with external system such as CAE tools. This paper can be a guide for engineering designers who want to customize CAD systems

  10. BUILDING A PERGOLA IN CAD SYSTEMS

    Directory of Open Access Journals (Sweden)

    PRUNA Liviu

    2017-05-01

    Full Text Available In this paper the authors present a study and the conclusions they reached, regarding the possibility to automatically representing a pergola, when a CAD system is used. Also, a computer program, made by the authors is presented. This software was named Pergola and it offer the opportunity to sketch a pergola which cover a rectangular or circular area, when using the AutoCAD Architecture or AutoCAD computer program.

  11. Development of integrated CAD system PV-1

    International Nuclear Information System (INIS)

    Miyamoto, Hitoshi; Ogawa, Kazuya; Shibata, Masayoshi.

    1997-01-01

    An integrated CAD system for pressure vessels, such as heat exchangers, drums, towers, jacketed vessels, and tanks, has been developed. The system is operated by MS-DOS personal computers combined in a LAN. Pressure vessel designers can work watching using the computer display because the system automatically manages design work, on a common data base. The project team members in other sections, such as production, cost control, and design, have the same data concurrently. Personal computers unite the 3D CAD system, and the generated design with detail dimensions and shapes is stored in the 3D CAD system automatically. The system has promoted higher design quality and greatly reduced design cost. (author)

  12. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    International Nuclear Information System (INIS)

    Benzakoun, Joseph; Bommart, Sébastien; Coste, Joël; Chassagnon, Guillaume; Lederlin, Mathieu; Boussouar, Samia

    2016-01-01

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  13. Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system

    Energy Technology Data Exchange (ETDEWEB)

    Benzakoun, Joseph, E-mail: benzakoun.joseph@gmail.com [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Bommart, Sébastien, E-mail: s-bommart@chu-montpellier.fr [CHU de Montpellier, 191 avenue du Doyen Gaston Giraud, 34000 Montpellier (France); INSERM U 1046, 371 avenue du Doyen G. Giraud, 34000 Montpellier (France); Coste, Joël, E-mail: joel.coste@htd.aphp.fr [Hôpital Hôtel-Dieu, 1 parvis Notre-Dame, 75004 Paris (France); Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Chassagnon, Guillaume, E-mail: gchassagnon@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Cochin, Radiologie, 27 rue du Faubourg Saint Jacques, 75014 Paris (France); Lederlin, Mathieu, E-mail: mathieu.lederlin@chu-rennes.fr [CHU de Rennes, Radiologie, 2 Rue Henri le Guilloux, 35000 Rennes (France); Université de Rennes 1, 9 Rue Jean Macé, 35000 Rennes (France); Boussouar, Samia, E-mail: samiaboussouar@gmail.com [Université Paris Descartes, 12 rue de l’Ecole de Médecine, 75006 Paris (France); Hôpital Européen Georges Pompidou, 20 Rue Leblanc, 75015 Paris (France); and others

    2016-10-15

    Highlights: • CAD sensitivity is still limited for automated detection of subsolid nodules. • CAD detection rate is higher for part-solid than for pure ground-glass nodules. • Part-solid nodule detection is not better for nodules with larger solid component. - Abstract: Objectives: To evaluate the performance of a commercially available CAD system for automated detection and measurement of subsolid nodules. Materials and methods: The CAD system was tested on 50 pure ground-glass and 50 part-solid nodules (median diameter: 17 mm) previously found on standard-dose CT scans in 100 different patients. True nodule detection and the total number of CAD marks were evaluated at different sensitivity settings. The influence of nodule and CT acquisition characteristics was analyzed with logistic regression. Software and manually measured diameters were compared with Spearman and Bland-Altman methods. Results: With sensitivity adjusted for 3-mm nodule detection, 50/100 (50%) subsolid nodules were detected, at the average cost of 17 CAD marks per CT. These figures were respectively 26/100 (26%) and 2 at the 5-mm setting. At the highest sensitivity setting (2-mm nodule detection), the average number of CAD marks per CT was 41 but the nodule detection rate only increased to 54%. Part–solid nodules were better detected than pure ground glass nodules: 36/50 (72%) versus 14/50 (28%) at the 3-mm setting (p < 0.0001), with no influence of the solid component size. Except for the type (i.e. part solid or pure ground glass), no other nodule characteristic influenced the detection rate. High-quality segmentation was obtained for 79 nodules, which for automated measurements correlated well with manual measurements (rho = 0.90[0.84–0.93]). All part-solid nodules had software-measured attenuation values above −671 Hounsfield units (HU). Conclusion: The detection rate of subsolid nodules by this CAD system was insufficient, but high-quality segmentation was obtained in 79% of

  14. Characterization analysis database system (CADS). A system overview

    International Nuclear Information System (INIS)

    1997-12-01

    The CADS database is a standardized, quality-assured, and configuration-controlled data management system developed to assist in the task of characterizing the DOE surplus HEU material. Characterization of the surplus HEU inventory includes identifying the specific material; gathering existing data about the inventory; defining the processing steps that may be necessary to prepare the material for transfer to a blending site; and, ultimately, developing a range of the preliminary cost estimates for those processing steps. Characterization focuses on producing commercial reactor fuel as the final step in material disposition. Based on the project analysis results, the final determination will be made as to the viability of the disposition path for each particular item of HEU. The purpose of this document is to provide an informational overview of the CADS database, its evolution, and its current capabilities. This document describes the purpose of CADS, the system requirements it fulfills, the database structure, and the operational guidelines of the system

  15. Software planning and analysis for automated design system AutoCAD

    OpenAIRE

    Koskutė, Lina

    2007-01-01

    AutoCAD sistemos papildymas sukurtas tam, kad būtų lengviau ir paprasčiau dirbti su AutoCAD grafine sistema. Funkcijos sukurtos naudojant AutoLisp ir VisualLISP programavimo kalbas. Sistemos papildymą galima įdiegti į bet kurią AutoCAD versiją. Sukurtas papildymas lankstus naujų funkcijų prijungimui, lengvai eksploatuojamas. Funkcijos suskirstytos į keletą grupių pagal jų formatą. AutoCAD system complement is created to make more easy working with AutoCAD graphic system. Functions are crea...

  16. Absorbing CAD system geometries into GEANT

    International Nuclear Information System (INIS)

    Womersley, J.; Dragovitsch, P.; Youssef, S.

    1991-01-01

    The simulation community has for many years discussed the possibility of direct conversion of geometrical detector models from computer- aided design and engineering systems (CAD systems) to the simulation packages (which we shall assume means GEANT). This would allow fast and simultaneous optimization of the physics performance and structural integrity of detector designs. The benefit that this would offer is the avoidance of such problems as the late discovery of the rather thick cryostats in the D-Zero detector. Recent progress in the absorption of CAD geometries into GEANT models is reviewed, including descriptions of the additions to the I-DEAS solid modeller package developed for the EMPACT SSC proposal, the COGENT CAD-to-GEANT interpreter developed by Quantum Research Services, and the OCTAGON package for representing arbitrary shapes in GEANT. Likely future directions of development are described. 2 refs., 7 figs

  17. Trend and application of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-09-01

    This report is about trend and application of CAD/CAM system, giving descriptions of computer aided design which helps construction, engineering and drafting tasks. It also tells of computer aided manufacturing related general design of manufactures, which includes process design, production management, decision of work technology, processing. The need and application of CAD/CAM system is increasing more and more for industry each area.

  18. XML-based assembly visualization for a multi-CAD digital mock-up system

    International Nuclear Information System (INIS)

    Song, In Ho; Chung, Sung Chong

    2007-01-01

    Using a virtual assembly tool, engineers are able to design accurate and interference free parts without making physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product in a distributed design environment. In this paper, a multi-CAD assembly method is proposed through an XML and the lightweight CAD file. XML data contains a hierarchy of the multi-CAD assembly. The lightweight CAD file produced from various CAD files through the ACIS kemel and InterOp includes not only mesh and B-Rep data, but also topological data. It is used to visualize CAD data and to verify dimensions of the parts. The developed system is executed on desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Multi-CAD models have been assembled to verify the effectiveness of the developed DMU system on the Internet

  19. PV-CAD: an integrated tool for designing PV facades; PV-CAD - Ein integriertes Werkzeug zur Auslegung von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Giese, H.; Viotto, M. [Inst. fuer Solare Energieversorgungstechnik (ISET) e.V., Kassel (Germany); Esser, M.; Pukrop, D. [Univ. Oldenburg (Germany). Abt. Energie- und Halbleiterforschung; Stellbogen, D. [Zentrum fuer Sonnenergie- und Wasserstoff-Forschung, Stuttgart (Germany)

    1997-12-31

    PV-CAD provides PV system planners with a practice-oriented tool for an efficient design of PV facades. Being compatible with the standard programmes of the architects` and electrical engineering sectors it can be used on already existing systems and allows the user to draw on previously acquired knowedge. Its open interfaces permit the integration of further design tools. PV CAD works under Microsoft Windows for which it has the necessary graphic user interface. Its compliance to PC standards opens up a wide range of applications and permits its use also on inexpensive computers. Thanks to its promotion by the Federal Ministry for Education, Science, Research, and Technology under the research project ``Computer programmes for the design of photovoltaic facades`` PV-CAD is available at a moderate price. PV-CAD permits an efficient planning of solar facades and therefore has the potential to stimulate the use of PV on buildings. (orig.) [Deutsch] Mit PV-CAD steht dem Anlagenplaner ein anwendungsorientiertes Werkzeug zur Verfuegung, das eine rationelle Auslegung von PV-Fassaden ermoeglicht. Die Kompatibilitaet zu Standardprogrammen aus dem Architektur- und Elektrosektor erlaubt die Nutzung bereits vorhandener Systeme und damit erworbener Kenntnisse. Offene Schnittstellen gestatten die Einbindung weiterer Entwurfswerkzeuge. PV-CAD arbeitet unter Microsoft-Windows und verfuegt ueber die entsprechende grafische Benutzerschnittstelle. Die Kompatibilitaet zum PC-Standard eroeffnet eine sehr breite Anwenderbasis und ermoeglicht den Einsatz des Programms auch auf preiswerten Rechnern. Aufgrund der Foerderung durch das Bundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie im Rahmen des Forschungsprojekts `Rechnerprogramm zur Auslegung von Photovoltaik-Fassaden` steht PV-CAD preiswert zur Verfuegung. PV-CAD ermoeglicht eine effiziente Planung von Solarfassaden und kann daher dem PV-Einsatz in Gebaeuden weitere Impulse geben. (orig.)

  20. Comprehensive Auto CAD

    International Nuclear Information System (INIS)

    Jang, Taekju

    1993-06-01

    This book starts introduction of conception, application system, software for CAD, function of Auto CAD, kinds and function of Auto CAD files. It deals with starting of Auto CAD, dialogue box and Auto CAD interface, utility command, 2D drawing command, check command, control system, dimension, hatching command, layer command, block, 3D drawing, plotting and printing, auto CAD and application of data, supply program of auto CAD, AME and region modeler, EDLIN, script optimization of Auto CAD and composition on demand.

  1. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  2. FY1995 transduction method and CAD database systems for integrated design; 1995 nendo transduction ho to CAD database togo sekkei shien system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for cooperative design using Transduction method. (4) Program development : Programs for Windows95 and developed for distribution. (NEDO)

  3. The CAD concept for stellarator-type magnetic systems

    International Nuclear Information System (INIS)

    Vorobyova, V.P.; Martynov, S.A.; Khazhmuradov, M.A.

    2002-01-01

    The paper describes the computer-aided design (CAD) concept for stellarator-type magnetic systems. Consideration is given to the main peculiarities, principles, and dialog organization and design stages of the CAD. The practical realization of the concept is illustrated by specific examples

  4. Optical properties of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E

    2014-09-01

    To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. A multi-user selective undo/redo approach for collaborative CAD systems

    Directory of Open Access Journals (Sweden)

    Yuan Cheng

    2014-04-01

    Full Text Available The engineering design process is a creative process, and the designers must repeatedly apply Undo/Redo operations to modify CAD models to explore new solutions. Undo/Redo has become one of most important functions in interactive graphics and CAD systems. Undo/Redo in a collaborative CAD system is also very helpful for collaborative awareness among a group of cooperative designers to eliminate misunderstanding and to recover from design error. However, Undo/Redo in a collaborative CAD system is much more complicated. This is because a single erroneous operation is propagated to other remote sites, and operations are interleaved at different sites. This paper presents a multi-user selective Undo/Redo approach in full distributed collaborative CAD systems. We use site ID and State Vectors to locate the Undo/Redo target at each site. By analyzing the composition of the complex CAD model, a tree-like structure called Feature Combination Hierarchy is presented to describe the decomposition of a CAD model. Based on this structure, the dependency relationship among features is clarified. B-Rep re-evaluation is simplified with the assistance of the Feature Combination Hierarchy. It can be proven that the proposed Undo/Redo approach satisfies the intention preservation and consistency maintenance correctness criteria for collaborative systems.

  6. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  7. Annotation and retrieval system of CAD models based on functional semantics

    Science.gov (United States)

    Wang, Zhansong; Tian, Ling; Duan, Wenrui

    2014-11-01

    CAD model retrieval based on functional semantics is more significant than content-based 3D model retrieval during the mechanical conceptual design phase. However, relevant research is still not fully discussed. Therefore, a functional semantic-based CAD model annotation and retrieval method is proposed to support mechanical conceptual design and design reuse, inspire designer creativity through existing CAD models, shorten design cycle, and reduce costs. Firstly, the CAD model functional semantic ontology is constructed to formally represent the functional semantics of CAD models and describe the mechanical conceptual design space comprehensively and consistently. Secondly, an approach to represent CAD models as attributed adjacency graphs(AAG) is proposed. In this method, the geometry and topology data are extracted from STEP models. On the basis of AAG, the functional semantics of CAD models are annotated semi-automatically by matching CAD models that contain the partial features of which functional semantics have been annotated manually, thereby constructing CAD Model Repository that supports model retrieval based on functional semantics. Thirdly, a CAD model retrieval algorithm that supports multi-function extended retrieval is proposed to explore more potential creative design knowledge in the semantic level. Finally, a prototype system, called Functional Semantic-based CAD Model Annotation and Retrieval System(FSMARS), is implemented. A case demonstrates that FSMARS can successfully botain multiple potential CAD models that conform to the desired function. The proposed research addresses actual needs and presents a new way to acquire CAD models in the mechanical conceptual design phase.

  8. Building of a CAD system for instrumentation and control system of nuclear power plant

    International Nuclear Information System (INIS)

    Ma Zhicai; Hu Chunping; Zhang Dongsheng

    2012-01-01

    Base on the analysis of deign documents and process, a database for instrumentation and control system design can be developed with a popular desktop relational database management system (RDBMS). With the RDBMS, an instrumentation and control system CAD system can be built unitizing database link feature of popular CAD software, with the function of management of design data, output of list and forms. and design of drawings. A CAD system of this kind has been used in the design practice of nuclear power plant. With this system, it is shown that, the consistency of information has been controlled and the load on the engineer has been significantly reduced. The methodology used here can also be used in the CAD system for CAP1000 and CAP1400 plant. (authors) series

  9. Introduction of effect and consideration of the introduction of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-12-01

    This reports introduction of effect and consideration of the introduction of computer-aided design and computer aided manufacturing system. It includes outline of CAD/CAM system like definition, classification, system kinds, and development process of CAD/CAM system, technology, market trend development prospect, and value on introduction of this system, and current application of CAD/CAM system in major application area, development countries and Korea.

  10. The microcomputer-based expert system in CAD-PV

    International Nuclear Information System (INIS)

    Wang, Y.; Qin, S.

    1987-01-01

    As a branch of artificial intelligence, expert system has been revealed day after day in more and more engineering scopes since the successful applications of MYCIN in diagnosis and DENDRAL in the molecular structure of organic compounds etc.. But in the design scope of pressure vessel, as we know, only a few papers have so far been published with respect to the expert system. The necessity and feasibility of accompanying CAD-PV with expert system attracted more scholars to engage in. Although many countries, including China, have regularized the design standards or codes for pressure vessel, but of which no one can solve all of the problems concerning the various practical occasions and experiences. In general, the more domain knowledges a design engineer possesses of, the better decision will be made by him. By virtue of the expert system any less experienced engineer could make the optimum decision in design as well as a skilled senior engineer in addition to the application of design code. It is the due significance for developing high level expert system as an intelligence assistant in the plan option of CAD-PV. In this paper we attempt to introduce a specified software JACKPV used in the design procedure of jacketed pressure vessel as an intelligence front in CAD-PV. JACKPV consists of the function of expert system based on the personal computer IBM-PC/XT with the language PASCAL in its program. It was proved that an ordinary CAD software could be effectively improved while equipped with expert system. (orig.)

  11. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    International Nuclear Information System (INIS)

    MORRIS, J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-01-01

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods

  12. CYBERSECURITY AND USER ACCOUNTABILITY IN THE C-AD CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    MORRIS,J.T.; BINELLO, S.; D OTTAVIO, T.; KATZ, R.A.

    2007-10-15

    A heightened awareness of cybersecurity has led to a review of the procedures that ensure user accountability for actions performed on the computers of the Collider-Accelerator Department (C-AD) Control System. Control system consoles are shared by multiple users in control rooms throughout the C-AD complex. A significant challenge has been the establishment of procedures that securely control and monitor access to these shared consoles without impeding accelerator operations. This paper provides an overview of C-AD cybersecurity strategies with an emphasis on recent enhancements in user authentication and tracking methods.

  13. CAD-centric Computation Management System for a Virtual TBM

    Energy Technology Data Exchange (ETDEWEB)

    Ramakanth Munipalli; K.Y. Szema; P.Y. Huang; C.M. Rowell; A.Ying; M. Abdou

    2011-05-03

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  14. TopoCad - A unified system for geospatial data and services

    Science.gov (United States)

    Felus, Y. A.; Sagi, Y.; Regev, R.; Keinan, E.

    2013-10-01

    "E-government" is a leading trend in public sector activities in recent years. The Survey of Israel set as a vision to provide all of its services and datasets online. The TopoCad system is the latest software tool developed in order to unify a number of services and databases into one on-line and user friendly system. The TopoCad system is based on Web 1.0 technology; hence the customer is only a consumer of data. All data and services are accessible for the surveyors and geo-information professional in an easy and comfortable way. The future lies in Web 2.0 and Web 3.0 technologies through which professionals can upload their own data for quality control and future assimilation with the national database. A key issue in the development of this complex system was to implement a simple and easy (comfortable) user experience (UX). The user interface employs natural language dialog box in order to understand the user requirements. The system then links spatial data with alpha-numeric data in a flawless manner. The operation of the TopoCad requires no user guide or training. It is intuitive and self-taught. The system utilizes semantic engines and machine understanding technologies to link records from diverse databases in a meaningful way. Thus, the next generation of TopoCad will include five main modules: users and projects information, coordinates transformations and calculations services, geospatial data quality control, linking governmental systems and databases, smart forms and applications. The article describes the first stage of the TopoCad system and gives an overview of its future development.

  15. Usefulness of the CAD System for Detecting Pulmonary Nodule in Real Clinical Practice

    International Nuclear Information System (INIS)

    Song, Kyoung Doo; Chung, Myung Jin; Kim, Hee Cheol; Lee, Kyung Soo; Jeong, Sun Young

    2011-01-01

    We wanted to evaluate the usefulness of the computer-aided detection (CAD) system for detecting pulmonary nodules in real clinical practice by using the CT images. Our Institutional Review Board approved our retrospective study with a waiver of informed consent. This study included 166 CT examinations that were performed for the evaluation of pulmonary metastasis in 166 patients with colorectal cancer. All the CT examinations were interpreted by radiologists and they were also evaluated by the CAD system. All the nodules detected by the CAD system were evaluated with regard to whether or not they were true nodules, and they were classified into micro nodules (MN, diameter < 4 mm) and significant nodules (SN, 4 ≤ diameter ≤ 10 mm). The radiologic reports and CAD results were compared. The CAD system helped detect 426 nodules: 115 (27%) of the 426 nodules were classified as true nodules and 35 (30%) of the 115 nodules were SNs, and 83 (72%) of the 115 were not mentioned in the radiologists' reports and three (4%) of the 83 nodules were non-calcified SNs. One of three non-calcified SNs was confirmed as a metastatic nodule. According to the radiologists' reports, 60 true nodules were detected, and 28 of the 60 were not detected by the CAD system. Although the CAD system missed many SNs that are detected by radiologists, it helps detect additional nodules that are missed by the radiologists in real clinical practice. Therefore, the CAD system can be useful to support a radiologist's detection performance

  16. Total Isolation Status Monitoring and Management System by CAD Assisted Technology

    International Nuclear Information System (INIS)

    Nakamura, Masaaki

    1995-01-01

    Isolation tasks in a nuclear power station require high confidence and quick response particularly during the annual inspection when the equipment must be checked in a safe and planned manner. To realize these advanced isolation works, JAPC has developed TOtal Isolation Status Monitoring and Management System using CAD Assisted Technology. This system, TOMM-CAT, developed under the concept of 'User friendly advanced man-machine interface', allows planning and management to be performed on a CRT display. TOMM-CAT allows isolation tasks to be performed accurately and efficiently in conjunction with equipment information from the existing Job Order Management System, which runs on the station host computer. (author)

  17. Lung nodule detection on chest CT: evaluation of a computer-aided detection (CAD) system

    International Nuclear Information System (INIS)

    Lee, In Jae; Gamsu, Gordon; Czum, Julianna; Johnson, Rebecca; Chakrapani, Sanjay; Wu, Ning

    2005-01-01

    To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results

  18. Progress of conversion system from CAD data to MCNP geometry data in Japan

    International Nuclear Information System (INIS)

    Sato, S.; Nashif, H.; Masuda, F.; Morota, H.; Iida, H.; Konno, C.

    2010-01-01

    Automatic conversion systems from CAD data to MCNP geometry input data have been developed to convert the CAD data of the fusion reactor with very complicated structure. So far, two conversion systems (GEOMIT-1 and ARCMCP) have been developed and the third system (GEOMIT-2) is under developing. The void data can be created in these systems. GEOMIT-1 was developed in 2007, but a lot of manual shape splitting work for the CAD data was required to convert the complicated geometry. ARCMCP was developed in 2008. The algorithm has been drastically improved on automatic creation of ambiguous surface in ARCMCP, but it still required a little manual shape splitting work. The latest system, GEOMIT-2, does not require additional commercial software packages, though the previous systems require them. It also has functions of the CAD data healing and the automatic shape splitting. Geometrical errors of CAD data can be automatically revised by the healing function, and complicated geometries can be automatically split into simple geometries by the shape splitting function. Any manual works for CAD data are not required in GEOMIT-2. GEOMIT-2 is very useful for nuclear analyses of fusion reactors.

  19. Improved algorithms and advanced features of the CAD to MC conversion tool McCad

    International Nuclear Information System (INIS)

    Lu, L.; Fischer, U.; Pereslavtsev, P.

    2014-01-01

    Highlights: •The latest improvements of the McCad conversion approach including decomposition and void filling algorithms is presented. •An advanced interface for the materials editing and assignment has been developed and added to the McCAD GUI. •These improvements have been tested and successfully applied to DEMO and ITER NBI (Neutral Beam Injector) applications. •The performance of the CAD model conversion process is shown to be significantly improved. -- Abstract: McCad is a geometry conversion tool developed at KIT to enable the automatic bi-directional conversions of CAD models into the Monte Carlo (MC) geometries utilized for neutronics calculations (CAD to MC) and, reversed (MC to CAD), for visualization purposes. The paper presents the latest improvements of the conversion algorithms including improved decomposition, void filling and an advanced interface for the materials editing and assignment. The new implementations and features were tested on fusion neutronics applications to the DEMO and ITER NBI (Neutral Beam Injector) models. The results demonstrate greater stability and enhanced efficiency of McCad conversion process

  20. ROCK-CAD - computer aided geological modelling system

    International Nuclear Information System (INIS)

    Saksa, P.

    1995-12-01

    The study discusses surface and solid modelling methods, their use and interfacing with geodata. Application software named ROCK-CAD suitable for geological bedrock modelling has been developed with support from Teollisuuden Voima Oy (TVO). It has been utilized in the Finnish site characterization programme for spent nuclear fuel waste disposal during the 1980s and 1990s. The system is based on the solid modelling technique. It comprises also rich functionality for the particular geological modelling scheme. The ROCK-CAD system provides, among other things, varying graphical vertical and horizontal intersections and perspective illustrations. The specially developed features are the application of the boundary representation modelling method, parametric object generation language and the discipline approach. The ROCK-CAD system has been utilized in modelling spatial distribution of rock types and fracturing structures in TVO's site characterization. The Olkiluoto site at Eurajoki serves as an example case. The study comprises the description of the modelling process, models and illustration examples. The utilization of bedrock models in site characterization, in tentative repository siting as well as in groundwater flow simulation is depicted. The application software has improved the assessment of the sites studied, given a new basis for the documentation of interpretation and modelling work, substituted hand-drawing and enabled digital transfer to numerical analysis. Finally, aspects of presentation graphics in geological modelling are considered. (84 refs., 30 figs., 11 tabs.)

  1. Computer-aided pulmonary nodule detection. Performance of two CAD systems at different CT dose levels

    International Nuclear Information System (INIS)

    Hein, Patrick Alexander; Rogalla, P.; Klessen, C.; Lembcke, A.; Romano, V.C.

    2009-01-01

    Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median also positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p>0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems. (orig.)

  2. Potential benefits of a CAD package for designing multivariable control systems

    International Nuclear Information System (INIS)

    Mensah, S.

    1983-01-01

    An open-ended CAD package, MVPACK, has been developed and implemented on a PDP-11/45 minicomputer at the Chalk River Nuclear Laboratories. The package is fully interactive, and includes a comprehensive state-of-the-art methematical library to support development of complex multi-variable control algorithms. Coded in RATFOR, MVPACK operates with a flexible data structure which makes efficient use of minicomputer resources and provides a standard framework for program generation. The existence of a help mechanism enhances the simplicity of package utilization. The capability of the package as a tool for designing control systems is illustrated with the design of a regulating system for an evaporator

  3. Research on AutoCAD secondary development and function expansion based on VBA technology

    Science.gov (United States)

    Zhang, Runmei; Gu, Yehuan

    2017-06-01

    AutoCAD is the most widely used drawing tool among the similar design drawing products. In the process of drawing different types of design drawings of the same product, there are a lot of repetitive and single work contents. The traditional manual method uses a drawing software AutoCAD drawing graphics with low efficiency, high error rate and high input cost shortcomings and many more. In order to solve these problems, the design of the parametric drawing system of the hot-rolled I-beam (steel beam) cross-section is completed by using the VBA secondary development tool and the Access database software with large-capacity storage data, and the analysis of the functional extension of the plane drawing and the parametric drawing design in this paper. For the secondary development of AutoCAD functions, the system drawing work will be simplified and work efficiency also has been greatly improved. This introduction of parametric design of AutoCAD drawing system to promote the industrial mass production and related industries economic growth rate similar to the standard I-beam hot-rolled products.

  4. Development of 3D CAD system as a design tool for PEACER development

    International Nuclear Information System (INIS)

    Lee, H. W.; Jung, K. J.; Jung, S. H.; Hwang, I. S.

    2003-01-01

    In an effort to resolve generic concerns with current power reactors, PEACER[1] has been developed as a proliferation-resistant waste transmutation reactor based on a unique combination of technologies of a prove a fast reactor and the heavy liquid metal coolant. In order to develop engineering design and visualize its performance, a three dimensional computer aided design (3D CAD) method has been devised. Based on conceptual design, system, structure and components of PEACER are defined. Using resuIts from finite element stress analyzer, computational fluid dynamics tool, nuclear analysis tool, etc, 3D visualization is achieved on the geometric construct based on CATIA[3]. A 3D visualization environment is utilized not only to overcome the integration complexity but also to manipulate data flow such as meshing information used in analysis codes. The 3D CAD system in this paper includes an open language, Virtual Reality Modeling Language (VRML)[4,5], to deliver analyses results on 3D objects, interactively. Such modeling environment is expected to improve the efficiency of designing the conceptual reactor, PEACER, reducing time and cost. ResuIts of 3D design and system performance simulation will be presented

  5. Productivity increase through implementation of CAD/CAE workstation

    Science.gov (United States)

    Bromley, L. K.

    1985-01-01

    The tracking and communication division computer aided design/computer aided engineering system is now operational. The system is utilized in an effort to automate certain tasks that were previously performed manually. These tasks include detailed test configuration diagrams of systems under certification test in the ESTL, floorplan layouts of future planned laboratory reconfigurations, and other graphical documentation of division activities. The significant time savings achieved with this CAD/CAE system are examined: (1) input of drawings and diagrams; (2) editing of initial drawings; (3) accessibility of the data; and (4) added versatility. It is shown that the Applicon CAD/CAE system, with its ease of input and editing, the accessibility of data, and its added versatility, has made more efficient many of the necessary but often time-consuming tasks associated with engineering design and testing.

  6. Using CAD/CAM-systems for process optimization during laser beam cutting and surface treatment. CAD/CAM-gestuetzte Prozessauslegung beim Laserstrahlschneiden und -oberflaechenveredeln

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, W.; Trasser, F.J.; Wetzels, W. (Fraunhofer-Inst. fuer Produktionstechnologie, IPT, Aachen (Germany))

    1991-02-01

    Using technological modules in modern CAD/CAM-systems provides an efficient use of the available know-how. On the one hand, companies can save their know-how, on the other hand they can improve manufacturing quality as well as increase the productivity. Especially laser beam cutting allows an automatic process control - orientated on geometry aspects. Similar results can be shown for laser surface treatment as well, although up to now reducing of the programming time is the main task of technological modules for this application, including special algorithms for CNC-controlled rotation/swiveling of powder-nozzles and adjustment of the powder flow rate.

  7. CAD-centric Computation Management System for a Virtual TBM. Final Report

    International Nuclear Information System (INIS)

    Munipalli, Ramakanth; Szema, K.Y.; Huang, P.Y.; Rowell, C.M.; Ying, A.; Abdou, M.

    2011-01-01

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  8. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  9. CDMS: CAD data set system design description. Revision 1

    International Nuclear Information System (INIS)

    Gray, E.L.

    1994-01-01

    This document is intended to formalize the program design of the CAD Data Set Management System (CDMS) and to be the vehicle to communicate the design to the Engineering, Design Services, and Configuration Management organizations and the WHC IRM Analysts/Programmers. The SDD shows how the software system will be structured to satisfy the requirements identified in the WHC-SD-GN-CSRS-30005 CDMS Software Requirement Specification (SRS). It is a description of the software structure, software components, interfaces, and data that make up the CDMS System. The design descriptions contained within this document will describe in detail the software product that will be developed to assist the aforementioned organizations for the express purpose of managing CAD data sets associated with released drawings, replacing the existing locally developed system and laying the foundation for automating the configuration management

  10. The VE/CAD synergism

    International Nuclear Information System (INIS)

    Sperling, R.B.

    1993-01-01

    Value Engineering (VE) and Computer-Aided Design (CAD) can be used synergistically to reduce costs and improve facilities designs. The cost and schedule impacts of implementing alternative design ideas developed by VE teams can be greatly reduced when the drawings have been produced with interactive CAD systems. To better understand the interrelationship between VE and CAD, the fundamentals of the VE process are explained; and example of a VE proposal is described and the way CAD drawings facilitated its implementation is illustrated

  11. Evolution of facility layout requirements and CAD [computer-aided design] system development

    International Nuclear Information System (INIS)

    Jones, M.

    1990-06-01

    The overall configuration of the Superconducting Super Collider (SSC) including the infrastructure and land boundary requirements were developed using a computer-aided design (CAD) system. The evolution of the facility layout requirements and the use of the CAD system are discussed. The emphasis has been on minimizing the amount of input required and maximizing the speed by which the output may be obtained. The computer system used to store the data is also described

  12. CAD system applications to the nuclear fuel reprocessing facilities

    International Nuclear Information System (INIS)

    Morita, Eiji; Matsumoto, Tadakuni; Shikakura, Sakae; Furuya, Kousei; Sakurai, Shin-ichi.

    1994-01-01

    Effective supporting techniques of design, operation, and maintenance of the reprocessing facility have been developed using the Intergraph CAD system. Two and three dimensional views of the process cells were utilized to rationalize the equipment layout and material handling flows, and to check the piping interference. Interferences of the remote maintenance equipment with the process equipments were also evaluated by the pictures on the CAD display. The newest virtual reality technology will help our future development of the more natural simulation for the remote maintenance operator training. (author)

  13. Easy Auto CAD

    International Nuclear Information System (INIS)

    Lee, Hyeon Jun

    1996-02-01

    This book explains Auto CAD easily, which introduces improved function in Auto CAD R 13, such as direct import and export of 3 DS pile, revised render order structure, and explanations of assist, view Draw, construct and modify. Next it gives descriptions of Auto CAD conception, application and system. The last part deals with line, arc, circle, ellipse, erase, undo, redo, redraw, line type, multi line, limits, zoom, move, copy, rotate, array, mirror, grid, snap, units, offset and poly line.

  14. When and why might a Computer Aided Detection (CAD) system interfere with visual search? An eye-tracking study

    Science.gov (United States)

    Drew, Trafton; Cunningham, Corbin; Wolfe, Jeremy

    2012-01-01

    Rational and Objectives Computer Aided Detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. Methods 47 naïve observers in two studies were asked to search for a target, embedded in 1/f2.4 noise while we monitored their eye-movements. For some observers, a CAD system marked 75% of targets and 10% of distractors while other observers completed the study without CAD. In Experiment 1, the CAD system’s primary function was to tell observers where the target might be. In Experiment 2, CAD provided information about target identity. Results In Experiment 1, there was a significant enhancement of observer sensitivity in the presence of CAD (t(22)=4.74, pCAD system were missed more frequently than equivalent targets in No CAD blocks of the experiment (t(22)=7.02, pCAD, but also no significant cost on sensitivity to unmarked targets (t(22)=0.6, p=n.s.). Finally, in both experiments, CAD produced reliable changes in eye-movements: CAD observers examined a lower total percentage of the search area than the No CAD observers (Ex 1: t(48)=3.05, pCAD signals do not combine with observers’ unaided performance in a straight-forward manner. CAD can engender a sense of certainty that can lead to incomplete search and elevated chances of missing unmarked stimuli. PMID:22958720

  15. Development of 3D CAD system as a design tool for PEACER development

    International Nuclear Information System (INIS)

    Jeong, Kwang Jin; Lee, Hyoung Won; Jeong, Seung Ho; Shin, Jong Gye; Hwang, Il Soon

    2003-01-01

    In an effort to resolve generic concerns with current power reactors, PEACER has been developed as a proliferation-resistant waste transmutation reactor based on a unique combination of technologies of a proven fast reactor and the heavy liquid metal coolant. In order to develop engineering design and visualize its performance, a three-dimensional computer aided design (3D CAD) method has been devised. Based on conceptual design, system, structure and components of PEACER are defined. Using results from finite element stress analyzer, computational fluid dynamics tool, nuclear analysis tool, etc, 3D visualization is achieved on the geometric construct based on CATIA. A 3D visualization environment is utilized not only to overcome the integration complexity but also to manipulate data flow such as meshing information used in analysis codes. The 3D CAD system in this paper includes an open language, Virtual Reality Modeling Language (VRML), to deliver analyses results on 3D objects, interactively. Such modeling environment is expected to improve the efficiency of designing the conceptual reactor, PEACER, reducing time and cost. Results of 3D design and stress analysis simulation will be presented as an example case. (author)

  16. Colour parameters and shade correspondence of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Pecho, Oscar E; Ghinea, Razvan; Cardona, Juan C; Pérez, María M

    2015-06-01

    To evaluate colour differences between (1) CAD-CAM ceramic systems considering shades A1, A2 and A3 and the corresponding nominal shade of VC (Vita Classical shade guide) and (2) shades A1-A2, A2-A3 and A1, A2 and A3 within the same ceramic system. Samples of shades A1, A2 and A3 were fabricated (n=5) from CAD-CAM ceramic blocks (IPS e.max(®) CAD LT and HT, IPS Empress(®) CAD LT and HT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. Spectral reflectance and colour coordinates were measured using a spectroradiometer inside a viewing booth using the CIE D65 illuminant and the d/0° geometry. Spectral reflectance curves were compared using VAF coefficient and were statistically analyzed using Kruskal-Wallis and the Mann-Whitney U test (α=0.05). Colour coordinates were statistically analyzed using one-way ANOVA, Tukey's test with Bonferroni correction (α=0.001). All colour differences (ΔEab(*) and ΔE00) were analyzed through comparisons with the PT - perceptibility and AT - acceptability thresholds for dental ceramics. ΔE between ceramic systems and its corresponding shade ranged from 6.32 to 13.42 (ΔEab(*)) and 4.48 to 9.30 (ΔE00). ΔE between shades A1-A2, A2-A3 and A1, A2 and A3 ranged, respectively, 1.93-4.82, 1.22-5.59 and 3.63-8.84 (ΔEab(*)); 1.54-3.87, 1.03-3.90 and 2.95-6.51 (ΔE00). Considering the corresponding nominal shade from VC, none of the ceramic systems showed colour differences below the AT. In addition, some ceramic systems showed colour differences below AT (shades A1-A2 and A2-A3) and below PT (shades A2-A3). Careful adjustments should be made to the final shade of CAD-CAM ceramic restorations to reach a clinically acceptable shade match. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    Science.gov (United States)

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  18. Improving the radiologist–CAD interaction: designing for appropriate trust

    International Nuclear Information System (INIS)

    Jorritsma, W.; Cnossen, F.; Ooijen, P.M.A. van

    2015-01-01

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist–CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the interaction between radiologists and the CAD system is not optimal. An important factor in the interaction between humans and automated aids (such as CAD) is trust. Suboptimal performance of the human–automation team is often caused by an inappropriate level of trust in the automation. In this review, we examine the role of trust in the radiologist–CAD interaction and suggest ways to improve the output of the CAD system so that it allows radiologists to calibrate their trust in the CAD system more effectively. Observer studies of the CAD systems show that radiologists often have an inappropriate level of trust in the CAD system. They sometimes under-trust CAD, thereby reducing its potential benefits, and sometimes over-trust it, leading to diagnostic errors they would not have made without CAD. Based on the literature on trust in human–automation interaction and the results of CAD observer studies, we have identified four ways to improve the output of CAD so that it allows radiologists to form a more appropriate level of trust in CAD. Designing CAD systems for appropriate trust is important and can improve the performance of the radiologist–CAD team. Future CAD research and development should acknowledge the importance of the radiologist–CAD interaction, and specifically the role of trust therein, in order to create the perfect artificial partner for the radiologist. This review focuses on the role of trust in the radiologist–CAD interaction. The aim of the review is to encourage CAD developers to design for appropriate trust and thereby improve the performance of the radiologist–CAD team. - Highlights: • Radiologists often have an inappropriate

  19. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    Science.gov (United States)

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  20. Application of 3-dimensional CAD modeling system in nuclear plants

    International Nuclear Information System (INIS)

    Suwa, Minoru; Saito, Shunji; Nobuhiro, Minoru

    1990-01-01

    Until now, the preliminary work for mutual components in nuclear plant were readied by using plastic models. Recently with the development of computer graphic techniques, we can display the components on the graphics terminal, better than with use of plastic model and actual plants. The computer model can be handled, both telescopically and microscopically. A computer technique called 3-dimensional CAD modeling system was used as the preliminary work and design system. Through application of this system, database for nuclear plants was completed in arrangement step. The data can be used for piping design, stress analysis, shop production, testing and site construction, in all steps. In addition, the data can be used for various planning works, even after starting operation of plant. This paper describes the outline of the 3-dimensional CAD modeling system. (author)

  1. Issues in assessing multi-institutional performance of BI-RADS-based CAD systems

    Science.gov (United States)

    Markey, Mia K.; Lo, Joseph Y.

    2005-04-01

    The purpose of this study was to investigate factors that impact the generalization of breast cancer computer-aided diagnosis (CAD) systems that utilize the Breast Imaging Reporting and Data System (BI-RADS). Data sets from four institutions were analyzed: Duke University Medical Center, University of Pennsylvania Medical Center, Massachusetts General Hospital, and Wake Forest University. The latter two data sets are subsets of the Digital Database for Screening Mammography. Each data set consisted of descriptions of mammographic lesions according to the BI-RADS lexicon, patient age, and pathology status (benign/malignant). Models were developed to predict pathology status from the BI-RADS descriptors and the patient age. Comparisons between the models built on data from the different institutions were made in terms of empirical (non-parametric) receiver operating characteristic (ROC) curves. Results suggest that BI-RADS-based CAD systems focused on specific classes of lesions may be more generally applicable than models that cover several lesion types. However, better generalization was seen in terms of the area under the ROC curve than in the partial area index (>90% sensitivity). Previous studies have illustrated the challenges in translating a BI-RADS-based CAD system from one institution to another. This study provides new insights into possible approaches to improve the generalization of BI-RADS-based CAD systems.

  2. Convex-based void filling method for CAD-based Monte Carlo geometry modeling

    International Nuclear Information System (INIS)

    Yu, Shengpeng; Cheng, Mengyun; Song, Jing; Long, Pengcheng; Hu, Liqin

    2015-01-01

    Highlights: • We present a new void filling method named CVF for CAD based MC geometry modeling. • We describe convex based void description based and quality-based space subdivision. • The results showed improvements provided by CVF for both modeling and MC calculation efficiency. - Abstract: CAD based automatic geometry modeling tools have been widely applied to generate Monte Carlo (MC) calculation geometry for complex systems according to CAD models. Automatic void filling is one of the main functions in the CAD based MC geometry modeling tools, because the void space between parts in CAD models is traditionally not modeled while MC codes such as MCNP need all the problem space to be described. A dedicated void filling method, named Convex-based Void Filling (CVF), is proposed in this study for efficient void filling and concise void descriptions. The method subdivides all the problem space into disjointed regions using Quality based Subdivision (QS) and describes the void space in each region with complementary descriptions of the convex volumes intersecting with that region. It has been implemented in SuperMC/MCAM, the Multiple-Physics Coupling Analysis Modeling Program, and tested on International Thermonuclear Experimental Reactor (ITER) Alite model. The results showed that the new method reduced both automatic modeling time and MC calculation time

  3. CAD-guidelines

    International Nuclear Information System (INIS)

    Schlechtendahl, E.G.; Lang-Lendorff, G.

    1982-10-01

    The CAD-guidelines (CAD = Computer Aided Design) contain rules for programming, structuring and documentation of programs. The standard deals with the structure of CAD-programs, their components, the programming-methods, the language etc. It describes what documents and references are necessary for a CAD-program. In order to gain a broad application of CAD criteria like portability and completeness of the documentation for an effective maintenance are as important as a transparent way of producing CAD-software. (orig.) [de

  4. Geometric data transfer between CAD systems: solid models

    DEFF Research Database (Denmark)

    Kroszynski, Uri; Palstroem, Bjarne; Trostmann, Erik

    1989-01-01

    The first phase of the ESPRIT project CAD*I resulted in a specification for the exchange of solid models as well as in some pilot implementations of processors based on this specification. The authors summarize the CAD*I approach, addressing the structure of neutral files for solids, entities......, and attributes supporting three kinds of representations: facilities for the transfer of parametric designs; referencing library components; and other general mechanisms. They also describe the current state of the specification and processor implementations and include an example of a CAD*I neutral file....... Results from cycle and intersystem solid model transfer tests are presented, showing the practicality of the CAD*I proposal. B-rep model transfer results are discussed in some detail. The relationship of this work to standardization efforts is outlined...

  5. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  6. A new data integration approach for AutoCAD and GIS

    Science.gov (United States)

    Ye, Hongmei; Li, Yuhong; Wang, Cheng; Li, Lijun

    2006-10-01

    GIS has its advantages both on spatial data analysis and management, particularly on the geometric and attributive information management, which has also attracted lots attentions among researchers around world. AutoCAD plays more and more important roles as one of the main data sources of GIS. Various work and achievements can be found in the related literature. However, the conventional data integration from AutoCAD to GIS is time-consuming, which also can cause the information loss both in the geometric aspects and the attributive aspects for a large system. It is necessary and urgent to sort out new approach and algorithm for the efficient high-quality data integration. In this paper, a novel data integration approach from AutoCAD to GIS will be introduced based on the spatial data mining technique through the data structure analysis both in the AutoCAD and GIS. A practicable algorithm for the data conversion from CAD to GIS will be given as well. By a designed evaluation scheme, the accuracy of the conversion both in the geometric and the attributive information will be demonstrated. Finally, the validity and feasibility of the new approach will be shown by an experimental analysis.

  7. The modular technology of development of the CAD expansions: protection of the buildings from the lightning

    OpenAIRE

    Migunov, Vladimir V.; Kafiyatullov, Rustem R.; Safin, Ilsur T.

    2004-01-01

    The modular technology of development of the problem-oriented CAD expansions is applied to a task of designing of protection of the buildings from the lightning with realization in program system TechnoCAD GlassX. The system model of the drawings of lightning protection is developed including the structured parametric representation (properties of objects and their interdependence, general settings and default settings) and operations with it, which efficiently automate designing

  8. Preparation of CAD infrastructure for ITER procurement packages allocated to Korea

    International Nuclear Information System (INIS)

    Kim, G.H.; Hwang, H.S.; Choi, J.H.; Lee, H.G.; Thomas, E.; Redon, F.; Wilhelm, B.

    2013-01-01

    Highlights: ► It is necessary to use the same CAD platform between project partners for efficient design collaboration. ► Several unexpected problems were found during preparation of the CAD infrastructure. ► The problems have resulted in a waste of time and cost. ► The approach using the same configurations is effective to avoid IT-related problems. ► The design activities are steadily being performed on the prepared ITER CAD platform. -- Abstract: It is necessary to use the same CAD platform for standardization and efficient design collaboration between project partners. ITER has selected CATIA with ENOVIA as the primary CAD and integration tool. During the preparation of the CAD infrastructure, there were several difficulties with respect to information technology (IT). ITER design is classified as mechanical and plant. The procurement arrangement is divided into three types; functional specification, detailed design, and build to print. Therefore, it is important to prepare the suitable prerequisites according to the design type, and to comply with CAD methodologies to avoid trial and error. This paper presents how to overcome the difficulties and how to perform the CAD activities for ITER Korea procurement packages including important matters on a CAD infrastructure in a big project

  9. The application of CAD / CAM technology in Dentistry

    Science.gov (United States)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  10. Effect of Home Bleaching on the Translucency of CAD/CAM Systems.

    Science.gov (United States)

    Karci, Muhammet; Demir, Necla

    2017-11-10

    To evaluate the effect of a home bleaching agent (Opalescence PF) on the translucency of CAD/CAM ceramic systems. The 28 sintered ceramic specimens (IPS Empress CAD and IPS e.max CAD; 15 mm long, 10 mm wide, 1 mm thick) were divided into two subgroups as control and bleaching groups (n = 7). Carbamide peroxide (CP), 16%, home bleaching agent was applied onto the surface of each specimen for 6 hours per day for 7 days. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L * a * b * coordinates and the reflectance value (Y) of the specimens on white and black backgrounds. The translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) of the specimens were calculated. The data were statistically analyzed using Kolmogorov-Smirnov, one-way ANOVA, Tukey's test, and Pearson's correlation. Statistically significant differences in the TP values after 16% CP bleaching treatment were observed (p ˂ 0.05); however, no significant differences were found in the OP and CR values after the surface treatment (p ˃ 0.05). According to our study, patients who have all-ceramic restorations in their mouths should be careful when using home bleaching agents, because whitening agents can affect the translucency of all-ceramic restorations such as e.max CAD and Empress CAD. © 2017 by the American College of Prosthodontists.

  11. AutoCAD

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1998-01-01

    I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium.......I 1998 var AutoCAD Arkitektskolens basale CAD-tilbud til de studerende. Kursets vægt ligger på konstruktion og strukturering af 3d-modeller og med udgangspunkt i dette, 2d-tegning. Kurset er opbygget over CAD Clasic skabelonen (se min forskning). Kompendiet kan bruges til selvstudium....

  12. A computer-aided detection (CAD) system with a 3D algorithm for small acute intracranial hemorrhage

    Science.gov (United States)

    Wang, Ximing; Fernandez, James; Deshpande, Ruchi; Lee, Joon K.; Chan, Tao; Liu, Brent

    2012-02-01

    Acute Intracranial hemorrhage (AIH) requires urgent diagnosis in the emergency setting to mitigate eventual sequelae. However, experienced radiologists may not always be available to make a timely diagnosis. This is especially true for small AIH, defined as lesion smaller than 10 mm in size. A computer-aided detection (CAD) system for the detection of small AIH would facilitate timely diagnosis. A previously developed 2D algorithm shows high false positive rates in the evaluation based on LAC/USC cases, due to the limitation of setting up correct coordinate system for the knowledge-based classification system. To achieve a higher sensitivity and specificity, a new 3D algorithm is developed. The algorithm utilizes a top-hat transformation and dynamic threshold map to detect small AIH lesions. Several key structures of brain are detected and are used to set up a 3D anatomical coordinate system. A rule-based classification of the lesion detected is applied based on the anatomical coordinate system. For convenient evaluation in clinical environment, the CAD module is integrated with a stand-alone system. The CAD is evaluated by small AIH cases and matched normal collected in LAC/USC. The result of 3D CAD and the previous 2D CAD has been compared.

  13. AutoCAD 2014 and AutoCAD LT 2014

    CERN Document Server

    Gladfelter, Donnie

    2013-01-01

    A step-by-step tutorial introduction to AutoCAD As the only book to teach AutoCAD using a continuous tutorial which allows you to follow along sequentially or jump in at any exercise by downloading the drawing files, this Autodesk Official Press book is ideal for the AutoCAD novice. Industry expert and AutoCAD guru Donnie Gladfelter walks you through the powerful features of AutoCAD, provides you with a solid foundation of the basics, and shares the latest industry standards and techniques. The hands-on tutorial project inspired by real-world workflows that runs throughout the book

  14. Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children

    Science.gov (United States)

    Zhang, Aifeng; Uyeda, Joshua; Tsao, Sinchai; Ma, Kevin; Vachon, Linda A.; Liu, Brent J.; Huang, H. K.

    2008-03-01

    Bone age assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on a left hand and wrist radiograph. The most commonly used standard: Greulich and Pyle (G&P) Hand Atlas was developed 50 years ago and exclusively based on Caucasian population. Moreover, inter- & intra-observer discrepancies using this method create a need of an objective and automatic BAA method. A digital hand atlas (DHA) has been collected with 1,400 hand images of normal children from Asian, African American, Caucasian and Hispanic descends. Based on DHA, a fully automatic, objective computer-aided-diagnosis (CAD) method was developed and it was adapted to specific population. To bring DHA and CAD method to the clinical environment as a useful tool in assisting radiologist to achieve higher accuracy in BAA, a web-based system with direct connection to a clinical site is designed as a novel clinical implementation approach for online and real time BAA. The core of the system, a CAD server receives the image from clinical site, processes it by the CAD method and finally, generates report. A web service publishes the results and radiologists at the clinical site can review it online within minutes. This prototype can be easily extended to multiple clinical sites and will provide the foundation for broader use of the CAD system for BAA.

  15. Coronary artery disease reporting and data system (CAD-RADSTM): Inter-observer agreement for assessment categories and modifiers.

    Science.gov (United States)

    Maroules, Christopher D; Hamilton-Craig, Christian; Branch, Kelley; Lee, James; Cury, Roberto C; Maurovich-Horvat, Pál; Rubinshtein, Ronen; Thomas, Dustin; Williams, Michelle; Guo, Yanshu; Cury, Ricardo C

    The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation. Copyright © 2017. Published by Elsevier Inc.

  16. The Enzyme Activity and Substrate Specificity of Two Major Cinnamyl Alcohol Dehydrogenases in Sorghum (Sorghum bicolor), SbCAD2 and SbCAD4.

    Science.gov (United States)

    Jun, Se-Young; Walker, Alexander M; Kim, Hoon; Ralph, John; Vermerris, Wilfred; Sattler, Scott E; Kang, ChulHee

    2017-08-01

    Cinnamyl alcohol dehydrogenase (CAD) catalyzes the final step in monolignol biosynthesis, reducing sinapaldehyde, coniferaldehyde, and p -coumaraldehyde to their corresponding alcohols in an NADPH-dependent manner. Because of its terminal location in monolignol biosynthesis, the variation in substrate specificity and activity of CAD can result in significant changes in overall composition and amount of lignin. Our in-depth characterization of two major CAD isoforms, SbCAD2 (Brown midrib 6 [bmr6]) and SbCAD4, in lignifying tissues of sorghum ( Sorghum bicolor ), a strategic plant for generating renewable chemicals and fuels, indicates their similarity in both structure and activity to Arabidopsis ( Arabidopsis thaliana ) CAD5 and Populus tremuloides sinapyl alcohol dehydrogenase, respectively. This first crystal structure of a monocot CAD combined with enzyme kinetic data and a catalytic model supported by site-directed mutagenesis allows full comparison with dicot CADs and elucidates the potential signature sequence for their substrate specificity and activity. The L119W/G301F-SbCAD4 double mutant displayed its substrate preference in the order coniferaldehyde > p -coumaraldehyde > sinapaldehyde, with higher catalytic efficiency than that of both wild-type SbCAD4 and SbCAD2. As SbCAD4 is the only major CAD isoform in bmr6 mutants, replacing SbCAD4 with L119W/G301F-SbCAD4 in bmr6 plants could produce a phenotype that is more amenable to biomass processing. © 2017 American Society of Plant Biologists. All Rights Reserved.

  17. AutoCAD 2008 and AutoCAD LT 2008 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    "Whether you're new to AutoCAD or a veteran, you will undoubtedly find this book to be an excellent resource."-- Abhi Singh, AutoCAD Product Manager, Autodesk, Inc.Here's the book that makes AutoCAD approachableEven the people at Autodesk look to Ellen Finkelstein for AutoCAD training, so who better to teach you about AutoCAD 2008? This comprehensive guide brings veterans up to speed on AutoCAD updates and takes novices from the basics to programming in AutoLISP(r) and VBA. Every feature is covered in a logical order, and with the Quick Start chapter, you'll be creating drawings on your very f

  18. AutoCAD 2015 and AutoCAD LT 2015 bible

    CERN Document Server

    Finkelstein, Ellen

    2014-01-01

    The perfect reference for all AutoCAD users AutoCAD 2015 and AutoCAD LT 2015 Bible is the book you want to have close at hand to answer those day-to-day questions about this industry-leading software. Author and Autodesk University instructor Ellen Finkelstein guides readers through AutoCAD 2015 and AutoCAD LT 2015 with clear, easy-to-understand instruction and hands-on tutorials that allow even total beginners to create a design on their very first day. Although simple and fundamental enough to be used by those new to CAD, the book is so comprehensive that even Autodesk power u

  19. CAD-based Monte Carlo automatic modeling method based on primitive solid

    International Nuclear Information System (INIS)

    Wang, Dong; Song, Jing; Yu, Shengpeng; Long, Pengcheng; Wang, Yongliang

    2016-01-01

    Highlights: • We develop a method which bi-convert between CAD model and primitive solid. • This method was improved from convert method between CAD model and half space. • This method was test by ITER model and validated the correctness and efficiency. • This method was integrated in SuperMC which could model for SuperMC and Geant4. - Abstract: Monte Carlo method has been widely used in nuclear design and analysis, where geometries are described with primitive solids. However, it is time consuming and error prone to describe a primitive solid geometry, especially for a complicated model. To reuse the abundant existed CAD models and conveniently model with CAD modeling tools, an automatic modeling method for accurate prompt modeling between CAD model and primitive solid is needed. An automatic modeling method for Monte Carlo geometry described by primitive solid was developed which could bi-convert between CAD model and Monte Carlo geometry represented by primitive solids. While converting from CAD model to primitive solid model, the CAD model was decomposed into several convex solid sets, and then corresponding primitive solids were generated and exported. While converting from primitive solid model to the CAD model, the basic primitive solids were created and related operation was done. This method was integrated in the SuperMC and was benchmarked with ITER benchmark model. The correctness and efficiency of this method were demonstrated.

  20. Dataudveksling mellem CAD og CAE programmer

    DEFF Research Database (Denmark)

    Sørensen, Torben; Conrad, Finn

    2001-01-01

    Når mange forskelligartede programmer benyttes til beregninger og anden databehandling på samme modeller er det nødvendig at udveksle modellerne mellem disse forskellige programmer. Biler og skibe bliver f.eks. typisk designet i 3D CAD systemer, mens CAD modellerne herefter anvendes i andre...... dedikerede IT-systemer i forbindelse montageplanlægningen, svejseplanlægningen, robotprogrammeringen mm. der således her et behov for at udveksle CAD modellen mellem de forskellige programmer. Udveksling af information mellem forskellige programmer og systemer kræver såvel en fælles specifikation af det...

  1. The Use of a Parametric Feature Based CAD System to Teach Introductory Engineering Graphics.

    Science.gov (United States)

    Howell, Steven K.

    1995-01-01

    Describes the use of a parametric-feature-based computer-aided design (CAD) System, AutoCAD Designer, in teaching concepts of three dimensional geometrical modeling and design. Allows engineering graphics to go beyond the role of documentation and communication and allows an engineer to actually build a virtual prototype of a design idea and…

  2. AutoCAD / AutoCAD LT 2014 fundamentals metric

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The objective of AutoCAD/AutoCAD LT 2014 Fundamentals is to enable students to create a basic 2D drawing in the AutoCAD software. Even at this fundamental level, the AutoCAD software is one of the most sophisticated computer applications that you are likely to encounter. Therefore learning to use it can be challenging. To make the process easier and provide flexibility for instructors and students, the training guide is divided into two parts that can be taken independently.

  3. Initial CAD investigations for NET

    International Nuclear Information System (INIS)

    Katz, F.; Leinemann, K.; Ludwig, A.; Marek, U.; Olbrich, W.; Schlechtendahl, E.G.

    1985-11-01

    This report summarizes the work done under contract no. 164/84-7/FU-D-/NET between the Commission of the European Communities and KfK during the period from June 1, 1984, through May 31, 1985. The following topics are covered in this report: Initial modelling of NET version NET2A, CAD system extension for remote handling studies, analysis of the CAD information structure, work related to the transfer of CAD information between KfK and the NET team. (orig.) [de

  4. Successfully converting mine maps to CAD

    Energy Technology Data Exchange (ETDEWEB)

    Munn, M.D. (Image Conversion Services, Inc., Salt Lake City, UT (USA))

    1991-03-01

    Procedures followed by computer service bureaus to convert paper drawing to digital files that can be used by CAD systems are described. The conversion involves laser scanning of original drawings to produce an 'inactive image' (a form suitable for many drawings that do not need to be changed). Using optical character recognition software the image is then vectorized or converted from raster format to geometric elements usable in a CAD system. The vectorized image can then be cleaned up corrected and changed at the CAD workstation. 4 figs.

  5. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Obenauer, S.; Hermann, K.P.

    2012-01-01

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  6. APPLICATION OF 3D DIGITAL SCANNING AND CAD/CAM SYSTEMS FOR ZIRCONIA INDIRECT RESTORATIONS

    Directory of Open Access Journals (Sweden)

    Mariela Tsanova

    2016-09-01

    Full Text Available Object: To study the CAD/CAM systems’ possibilities for manufacturing Zirconia indirect restorations for restoring vital, vastly devastated teeth. Material and methods: Five patients with vital, heavily destroyed molars were included in the clinical study. The teeth were prepared according to requirements for Zirconia restorations. The impressions were taken with 3D intraoral scanner. The acquired data is transmitted electronically for designing the future restoration by the CAD software. After designing, the restoration is milled by the CAM module and sintered, according to a specially projected programme in accordance with the manufacturing demands. After clinical check-up, the restorations are glazed, air-blasted and cemented. Results: Setting up an individual protocol for working with CAD/CAM systems for restoring vital, severely devastated teeth with Zirconia indirect restorations. A research is made on 3D digital scanning, occlusal and proximal modeling, virtual articulation, analyzing the incline of the cavity walls, the thickness of the restoration and the possibilities for restoring the anatomy of the tooth according to patient’s individual characteristics of the teeth’s arch. Conclusion: The scanning and design process should be evaluated with the same quality control as when using traditional methods. The CAD software requires excellent preparation of the tooth cavity and digital scanning. This is the reason why these systems require a thorough understanding of CAD/CAM calibration and parameters of the product to be clinically acceptable. Once understood, CAD/CAM dentistry can create detailed and accurate restorations that function and perform with great success and longevity.

  7. Role of radiologists in CAD life-cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pietka, Ewa, E-mail: ewa.pietka@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Kawa, Jacek, E-mail: jacek.kawa@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Spinczyk, Dominik, E-mail: dominik.spinczyk@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Badura, Pawel, E-mail: pawel.badura@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Wieclawek, Wojciech, E-mail: wojciech.wieclawek@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Czajkowska, Joanna, E-mail: joanna.czajkowska@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland); Rudzki, Marcin, E-mail: marcin.rudzki@polsl.pl [Silesian University of Technology, Faculty of Automatic Control, Electronics and Computer Science, ul. Akademicka 16, 44-100 Gliwice (Poland)

    2011-05-15

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  8. Role of radiologists in CAD life-cycle

    International Nuclear Information System (INIS)

    Pietka, Ewa; Kawa, Jacek; Spinczyk, Dominik; Badura, Pawel; Wieclawek, Wojciech; Czajkowska, Joanna; Rudzki, Marcin

    2011-01-01

    A modern CAD (computer-aided diagnosis) system development involves a multidisciplinary team whose members are experts in medical and technical fields. This study indicates the activities of medical experts at various stages of the CAD design, testing, and implementation. Those stages include a medical analysis of the diagnostic problem, data collection, image analysis, evaluation, and clinical verification. At each stage the physicians knowledge and experience are indispensable. The final implementation involves integration with the existing Picture Archiving and Communication System. The term CAD life-cycle describes an overall process of the design, testing, and implementation of a system that in its final form assists the radiologists in their daily clinical routine. Four CAD systems (applied to the bone age assessment, Multiple Sclerosis detection, lung nodule detection, and pneumothorax measurement) developed in our laboratory are given as examples of how consecutive stages are developed by the multidisciplinary team. Specific advantages of the CAD implementation that include the daily clinical routine as well as research and education activities are discussed.

  9. Simultaneous detection and classification of breast masses in digital mammograms via a deep learning YOLO-based CAD system.

    Science.gov (United States)

    Al-Masni, Mohammed A; Al-Antari, Mugahed A; Park, Jeong-Min; Gi, Geon; Kim, Tae-Yeon; Rivera, Patricio; Valarezo, Edwin; Choi, Mun-Taek; Han, Seung-Moo; Kim, Tae-Seong

    2018-04-01

    Automatic detection and classification of the masses in mammograms are still a big challenge and play a crucial role to assist radiologists for accurate diagnosis. In this paper, we propose a novel Computer-Aided Diagnosis (CAD) system based on one of the regional deep learning techniques, a ROI-based Convolutional Neural Network (CNN) which is called You Only Look Once (YOLO). Although most previous studies only deal with classification of masses, our proposed YOLO-based CAD system can handle detection and classification simultaneously in one framework. The proposed CAD system contains four main stages: preprocessing of mammograms, feature extraction utilizing deep convolutional networks, mass detection with confidence, and finally mass classification using Fully Connected Neural Networks (FC-NNs). In this study, we utilized original 600 mammograms from Digital Database for Screening Mammography (DDSM) and their augmented mammograms of 2,400 with the information of the masses and their types in training and testing our CAD. The trained YOLO-based CAD system detects the masses and then classifies their types into benign or malignant. Our results with five-fold cross validation tests show that the proposed CAD system detects the mass location with an overall accuracy of 99.7%. The system also distinguishes between benign and malignant lesions with an overall accuracy of 97%. Our proposed system even works on some challenging breast cancer cases where the masses exist over the pectoral muscles or dense regions. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. AutoCAD 2012 and AutoCAD LT 2012 Bible

    CERN Document Server

    Finkelstein, Ellen

    2011-01-01

    The latest version of this perennial favorite, in-depth, reference-tutorial This top-selling book has been updated by AutoCAD guru and author Ellen Finkelstein to provide you with the very latest coverage of both AutoCAD 2012 and AutoCAD LT 2012. It begins with a Quick Start tutorial, so you start creating right away. From there, the book covers so much in-depth material on AutoCAD that it is said that even Autodesk employees keep this comprehensive book at their desks. A DVD is included that features before-and-after drawings of all the tutorials and plenty of great examples from AutoCAD prof

  11. Computing Mass Properties From AutoCAD

    Science.gov (United States)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  12. Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

    International Nuclear Information System (INIS)

    Choi, Eun Jung; Jin, Gong Yong; Han, Young Min; Lee, Young Sun; Kweon, Keun Sang

    2008-01-01

    We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within ± 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. The CAD system was a useful tool for diagnosing malignant SPNs

  13. Application of CAD/CAE/CAM in forging process: a review

    International Nuclear Information System (INIS)

    Ahmad Baharuddin Abdullah; Hamouda, A.M.S.

    2005-01-01

    Forging can be described as the process in which metal is plastically deformed with application of huge pressure. The process not only changes the shape but also improves the properties of the forged parts due to grain size refinement. Conventionally, the empirical trial and error method has been applied, but recently there are various tools are employed to improved product quality and economic of the process. For example, Computer Aided Design (CAD) is widely used in modeling of the process, while Computer Aided Engineering (CAE) tools have been utilized in analyzing the process. To physically demonstrate the process, Computer Aided Manufacturing (CAM) such as CNC machine has been exploited. In order to improve forging process efficiency, an integrated system that combines all advantages of CAD, CAM and CAE need to be developed. This paper presents an overview of computer aided simulation such as CAD, CAE and CAM application in forging process. (Author)

  14. A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas

    Science.gov (United States)

    Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.

    2007-03-01

    Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.

  15. Integration of computer-aided diagnosis/detection (CAD) results in a PACS environment using CAD-PACS toolkit and DICOM SR

    International Nuclear Information System (INIS)

    Le, Anh H.T.; Liu, Brent; Huang, H.K.

    2009-01-01

    Picture Archiving and Communication System (PACS) is a mature technology in health care delivery for daily clinical imaging service and data management. Computer-aided detection and diagnosis (CAD) utilizes computer methods to obtain quantitative measurements from medical images and clinical information to assist clinicians to assess a patient's clinical state more objectively. CAD needs image input and related information from PACS to improve its accuracy; and PACS benefits from CAD results online and available at the PACS workstation as a second reader to assist physicians in the decision making process. Currently, these two technologies remain as two separate independent systems with only minimal system integration. This paper describes a universal method to integrate CAD results with PACS in its daily clinical environment. The method is based on Health Level 7 (HL7) and Digital imaging and communications in medicine (DICOM) standards, and Integrating the Healthcare Enterprise (IHE) workflow profiles. In addition, the integration method is Health Insurance Portability and Accountability Act (HIPAA) compliant. The paper presents (1) the clinical value and advantages of integrating CAD results in a PACS environment, (2) DICOM Structured Reporting formats and some important IHE workflow profiles utilized in the system integration, (3) the methodology using the CAD-PACS integration toolkit, and (4) clinical examples with step-by-step workflows of this integration. (orig.)

  16. AutoCAD platform customization autolisp

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Customize and personalize programs built on the AutoCAD platform AutoLISP is the key to unlocking the secrets of a more streamlined experience using industry leading software programs like AutoCAD, Civil 3D, Plant 3D, and more. AutoCAD Platform Customization: AutoLISP provides real-world examples that show you how to do everything from modifying graphical objects and reading and setting system variables to communicating with external programs. It also features a resources appendix and downloadable datasets and customization examples-tools that ensure swift and easy adoption. Find out how to r

  17. Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

    Science.gov (United States)

    Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil

    2015-08-01

    This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (Pmarginal discrepancy (Pmarginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.

  18. CAD for CT colonography: toward a preparation-independent scheme

    International Nuclear Information System (INIS)

    Naeppi, J.

    2007-01-01

    Computer-aided detection (CAD) systems can be used to automatically detect and display the locations of polyps and masses in computed tomographic colonography (CTC) data for assisting radiologists' image interpretation. Rapid technical advancements over the last few years have established a fundamental CAD scheme for CTC that includes the steps of colon extraction, polyp detection, and false-positive (FP) reduction. Several CAD prototype systems have demonstrated clinically acceptable high polyp detection sensitivity with relatively few FP detections in cathartic CTC, and observer studies have demonstrated the potential benefit of such systems in improving the accuracy and consistency of radiologists' detection performance. Some CAD prototype systems have also demonstrated promising performance in reduced cathartic and non-cathartic CTC. Recent advancements suggest that CAD systems can soon be expected to provide a preparation-independent scheme that can yield consistently high detection sensitivity with moderately low FP rate not only with cathartic CTC protocols but over a wide range of cathartic, reduced cathartic, and non-cathartic CTC protocols. (orig.)

  19. Bomb CAD

    International Nuclear Information System (INIS)

    Massa, R.J.; Howard, J.W.

    1989-01-01

    This paper describes BombCAD a computer-aided analysis technique for assessing the damage to diverse structures which results from specific high explosive detonations within or near the structure. BombCAD analyzes the vulnerability of specific facilities to bomb attach, and evaluates siting, screening and hardening/softening aspects of comprehensive bomb defense programs. The paper describes BombCAD's architectural models of specific structures, computations of blastwave effects and the paradigms which relate blast wave effects to both structural damage and human injury. The use of BombCAD in bomb attack vulnerability assessment, facility design, bomb threat response planning and post-incident analyses is described and field examples are presented

  20. The review of CAD for simulation of microwave devices

    Directory of Open Access Journals (Sweden)

    Drach V.E.

    2017-01-01

    Full Text Available the article is devoted to a brief review of modern CAD for electromagnetic modeling of microwave devices. Five major CAD systems are described in the article: FEKO, μWave Wizard, Sonnet, AWR Microwave Office, HFSS. The main methods are given for each CAD system used for simulation of microwave structures and the main advantages that distinguish its use.

  1. CAD-based Monte Carlo program for integrated simulation of nuclear system SuperMC

    International Nuclear Information System (INIS)

    Wu, Y.; Song, J.; Zheng, H.; Sun, G.; Hao, L.; Long, P.; Hu, L.

    2013-01-01

    SuperMC is a (Computer-Aided-Design) CAD-based Monte Carlo (MC) program for integrated simulation of nuclear systems developed by FDS Team (China), making use of hybrid MC-deterministic method and advanced computer technologies. The design aim, architecture and main methodology of SuperMC are presented in this paper. The taking into account of multi-physics processes and the use of advanced computer technologies such as automatic geometry modeling, intelligent data analysis and visualization, high performance parallel computing and cloud computing, contribute to the efficiency of the code. SuperMC2.1, the latest version of the code for neutron, photon and coupled neutron and photon transport calculation, has been developed and validated by using a series of benchmarking cases such as the fusion reactor ITER model and the fast reactor BN-600 model

  2. Theory and practice of Auto CAD, computer graphics

    International Nuclear Information System (INIS)

    Hwang, Si Won; Choe, Hong Yeong; Shin, Jae Yeon; Lee, Ryong Cheol

    1990-08-01

    This book describes theory and practice of Auto CAD, computer graphics, which deals with peripheral of computer, occurrence of digital line by DDA, BRM, theory of conversion, data base and display and shape modeling. This book gives descriptions of outline of CAD system, Auto CAD, basic function practice, simple figure practice, the third angle projection drawing a little complex single object, machine drawing I, function practice of improved Auto CAD, edit, set up layer, and 3D, and 3D display function.

  3. Automated knowledge base development from CAD/CAE databases

    Science.gov (United States)

    Wright, R. Glenn; Blanchard, Mary

    1988-01-01

    Knowledge base development requires a substantial investment in time, money, and resources in order to capture the knowledge and information necessary for anything other than trivial applications. This paper addresses a means to integrate the design and knowledge base development process through automated knowledge base development from CAD/CAE databases and files. Benefits of this approach include the development of a more efficient means of knowledge engineering, resulting in the timely creation of large knowledge based systems that are inherently free of error.

  4. Strategies for the Curation of CAD Engineering Models

    Directory of Open Access Journals (Sweden)

    Manjula Patel

    2009-06-01

    Full Text Available Normal 0 Product Lifecycle Management (PLM has become increasingly important in the engineering community over the last decade or so, due to the globalisation of markets and the rising popularity of products provided as services. It demands the efficient capture, representation, organisation, retrieval and reuse of product data over its entire life. Simultaneously, there is now a much greater reliance on CAD models for communicating designs to manufacturers, builders, maintenance crews and regulators, and for definitively expressing designs. Creating the engineering record digitally, however, presents problems not only for its long-term maintenance and accessibility - due in part to the rapid obsolescence of the hardware, software and file formats involved - but also for recording the evolution of designs, artefacts and products. We examine the curation and preservation requirements in PLM and suggest ways of alleviating the problems of sustaining CAD engineering models through the use of lightweight formats, layered annotation and the collection of Representation Information as defined in the Open Archival Information System (OAIS Reference Model.  We describe two tools which have been specifically developed to aid in the curation of CAD engineering models in the context of PLM: Lightweight Models with Multilayered Annotation (LiMMA and a Registry/Repository of Representation Information for Engineering (RRoRIfE.

  5. Improving the radiologist-CAD interaction : designing for appropriate trust

    NARCIS (Netherlands)

    Jorritsma, W.; Cnossen, F.; van Ooijen, P. M. A.

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist-CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the

  6. Integrated CAD/CAE for nuclear power plants

    International Nuclear Information System (INIS)

    Lecoq, P.; Lachat, J.C.

    1987-01-01

    The size of the French nuclear power program has led both EDF and Framatome to equip themselves progressively with management software, computer-assisted design (CAD) systems, and computer-assisted engineering (CAE) systems. The nature of the projects and of the respective activities of EDF and Framatome determined the essential specifications of these computerized systems. EDF and Framatome have pooled their CAD/CAE efforts in a joint venture (Groupement d'Interet Economique) called GIAO, set up in 1985 by EDF and Aquitaine Systeme (a subsidiary of Framatome and Elf Aquitaine). GIAO's ambition is to become a pole of French CAD/CAE efforts and to foster progress in integrated computer-assisted engineering, by enlarging the synergy of EDF and Framatome in this field to other enterprises that participate in design and construction of complex industrial plants

  7. Application of the V.R. technology to the 3D-CAD system for nuclear plant

    International Nuclear Information System (INIS)

    Katoh, Toshisada; Tanaka, Kazuo; Kasai, Yasusuke; Kimura, Katsumi; Nakakoshi, Tetsuhiro

    1993-01-01

    The technology of the V.R. (Virtual Reality) is expected to improve the interface between the human and the computer by reality and easiness. The application of the V.R. technology to the nuclear power plant will bring the wide-spread use of the computer in various fields such as plant planning, design, training, and operation. The combination of the 3D-CAD plant data and the V.R. technologies will be easy approach to realize these applications because the 3D-CAD data for nuclear plant is constructed in the design stage. The prototype system investigates the feasibility of V.R. technologies in the nuclear plant. The stereo-scopic device and the voice processing device has been integrated to 3D-CAD system by 1992. We confirmed that these devices have a good effect on the improvement of the interface between the man and the computer. (orig.)

  8. Retrospective analysis of a Computer-Aided Detection (CAD) system in full-field digital mammography in correlation to tumor histology

    International Nuclear Information System (INIS)

    Obenauer, S.; Sohns, C.; Grabbe, E.; Werner, C.

    2005-01-01

    Purpose: to evaluate the usefulness of a computer-aided detection (CAD) system in full-field digital mammography in correlation to tumor histology. Material and methods: a total of 476 patients (226 patients with histologically proven malignant tumors, 250 healthy women) took part in this study. The mammograms were studied retrospectively, using the CAD system Image Checker. For 226 patients digital mammograms in MLO-projection were available. For 186 of these patients the CC-projection was also available. CAD markers that correlated with histologically proven carcinomas were considered to be true-positive markers. All other CAD markers were considered to be false-positive. Histologically proven carcinomas without markers were false-negative results. The dependence of the CAD markers placement upon the different carcinoma histologies was studied using the Chi-square test. Results: no significant difference could be proven for the detectability of malignant breast lesions of different histologic types. For the detectability of ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), lobular carcinoma in situ (LCIS), tubular carcinoma and ductulo-lobular carcinoma, the true positives were 71.1%, 75%, 70.7%, 70%, 60% and 80%, respectively, in the MLO projection and 83.9%, 75.9%, 81.8%, 77.8%, 87.5% and 33.3%, respectively, in the CC projection. There was an average of 0.5 false-positive markers per mammographic image. Conclusion: The histologic type of carcinoma seems to have no influence on detectability when using the CAD system. The high rate of false-positive markers shows, however, the limited specificity of the CAD system and that improvements are necessary. (orig.)

  9. Are unnecessary follow-up procedures induced by computer-aided diagnosis (CAD) in mammography? Comparison of mammographic diagnosis with and without use of CAD

    International Nuclear Information System (INIS)

    Marx, Christiane; Malich, Ansgar; Facius, Mirjam; Grebenstein, Uta; Sauner, Dieter; Pfleiderer, Stefan O.R.; Kaiser, Werner A.

    2004-01-01

    Objective: To evaluate the rate of unnecessary follow-up procedures recommended by radiologists using a CAD-system. Materials and methods: 185 patients (740 images) were consecutively selected from three groups (36 histologically proven cancers=group 1; 49 histologically proven benign lesions=group 2 and 100 screening cases (4 years-follow up=group 3). Mammograms were evaluated by a CAD system (Second Look [reg] , CADx, Canada). Five blinded radiologists assessed the images without/with CAD outputs. Diagnostic decisions were ranked from surely benign to surely malignant according to BIRADS classification, follow-up procedures were recommended for each observed lesion (a, screening; b, short interval follow-up examination in 6 months; c, pathologic clarification). Results: CAD-system detected 32/36 cancers (88.9%) (FP-rate: 1.04 massmarks and 0.27 calcmarks/image). The following values were reached by all observers without/with CAD in the mean: Sensitivity 80.6/80.0%, specificity 83.2/86.4%, PPV 53.1/58.1%, and NPV 94.6/94.7%. Observers described a similar number of additional lesions without/with the use of CAD (325/326). Whereas the number of unnecessary short-time follow up recommendations increased in all case-subgroups with CAD: 40.8/42.9% (group 1), 35.6/38.1% (group 2), 44.7/46.8% (group 3), respectively, the number of recommended biopsies decreased in all subgroups: group 1: 34.7/27.1%; group 2: 47.4/41.5%, group 3: 33.3/22.0%, respectively. Conclusion: In this rather small population additional usage of CAD led to a lower rate of unnecessary biopsies. The observed decrease of recommended unnecessary biopsies due to the usage of CAD in the screening group suggests a potential financial benefit by using CAD as diagnostic aid

  10. Optimizing Case-based detection performance in a multiview CAD system for mammography

    NARCIS (Netherlands)

    Samulski, M.; Karssemeijer, N.

    2011-01-01

    When reading mammograms, radiologists combine information from multiple views to detect abnormalities. Most computer-aided detection (CAD) systems, however, use primitive methods for inclusion of multiview context or analyze each view independently. In previous research it was found that in

  11. Longevity of Single-Tooth All-Ceramic CAD/CAM Restorations: A Meta-Analysis

    Science.gov (United States)

    2013-07-01

    to the application of CAD/CAM technology in dentistry . The initial monetary investment for the equipment is significant. Systems currently on the...CURRENT DENTAL CAD/CAM SYSTEMS Current CAD/CAM systems in dentistry include: CEREC (CEramic REConstruction) and CEREC Acquisition Center (AC) with...of Adhesive Dentistry , 1 (3), 255- 265. 42     Bindl A, & Mörmann W. (2002). An up to 5-year clinical evaluation of posterior In- Ceram CAD

  12. Flexural resistance of Cerec CAD/CAM system ceramic blocks. Part 2: Outsourcing materials.

    Science.gov (United States)

    Sedda, Maurizio; Vichi, Alessandro; Del Siena, Francesco; Louca, Chris; Ferrari, Marco

    2014-02-01

    To test different Cerec CAD/CAM system ceramic blocks, comparing mean flexural strength (sigma), Weibull modulus (m), and Weibull characteristic strength (sigma0) in an ISO standardized set-up. Following the recent ISO Standard (ISO 6872:2008), 11 types of ceramic blocks were tested: IPS e.max CAD MO, IPS e.max CAD LT and IPS e.max CAD HT (lithium disilicate glass-ceramic); In-Ceram SPINELL, In-Ceram Alumina and In-Ceram Zirconia (glass-infiltrated materials); inCoris AL and In-Ceram AL (densely sintered alumina); In-Ceram YZ, IPS e.max Zir-CAD and inCoris ZI (densely sintered zirconia). Specimens were cut out from ceramic blocks, finished, crystallized/infiltrated/sintered, polished, and tested in a three-point bending test apparatus. Flexural strength, Weibull characteristic strength, and Weibull modulus were obtained. A statistically significant difference was found (P ceramic (sigma = 272.6 +/- 376.8 MPa, m = 6.2 +/- 11.3, sigma0 = 294.0 +/- 394.1 MPa) and densely sintered alumina (sigma = 441.8 +/- 541.6 MPa, m = 11.9 +/- 19.0, sigma0 = 454.2 +/- 565.2 MPa). No statistically significant difference was found (P = 0.254) in glass infiltrated materials (sigma = 376.9 +/- 405.5 MPa, m = 7.5 +/- 11.5, sigma0 = 393.7 +/- 427.0 MPa). No statistically significant difference was found (P = 0.160) in densely sintered zirconia (sigma = 1,060.8 +/- 1,227.8 MPa, m = 5.8 +/- 7.4, sigma0 = 1,002.4 +/- 1,171.0 MPa). Not all the materials tested fulfilled the requirements for the clinical indications recommended by the manufacturer.

  13. Progress of computer-aided detection/diagnosis (CAD in dentistryCAD in dentistry

    Directory of Open Access Journals (Sweden)

    Akitoshi Katsumata

    2014-08-01

    CAD is also useful in the detection and evaluation of dental and maxillofacial lesions. Identifying alveolar bone resorption due to periodontitis and radiolucent jaw lesions (such as radicular and dentigerous cysts are important goals for CAD. CAD can be applied not only to panoramic radiography but also to dental cone-beam computed tomography (CBCT images. Linking of CAD and teleradiology will be an important issue.

  14. AutoCAD 2015 and AutoCAD LT 2015 essentials

    CERN Document Server

    Onstott, Scott

    2014-01-01

    Step-by-step instructions for the AutoCAD fundamentals AutoCAD 2015 Essentials contains 400 pages of full-color, comprehensive instruction on the world's top drafting and architecture software. This 2015 edition features architectural, manufacturing, and landscape architecture examples. And like previous editions, the detailed guide introduces core concepts using interactive tutorials and open-ended projects, which can be completed in any order, thanks to downloadable data sets (an especially useful feature for students and professionals studying for Autodesk AutoCAD certification). Unlike man

  15. MS AutoCad

    DEFF Research Database (Denmark)

    Andersen, Michael Rye; Heinicke, Hugo

    1996-01-01

    Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund for praktiskprojekter......Formålet med dette notat er at give en introduktion til tegning af et generalarrangement ved anvendelse af CAD-programmet AutoCAD. Generalarrangementets formål er at skabe en overskuelig præsentation af et skibsprojekt. Det skal gøres indenfor de rammer, som ligger til grund...

  16. Use of McCad for the conversion of ITER CAD data to MCNP geometry

    International Nuclear Information System (INIS)

    Tsige-Tamirat, H.; Fischer, U.; Serikov, A.; Stickel, S.

    2008-01-01

    The program McCad provides a CAD interface for the Monte Carlo transport code MCNP. It is able to convert CAD data into MCNP input geometry description and provides GUI components for modeling, visualization, and data exchange. It performs sequences of tests on CAD data to check its validity and neutronics appropriateness including completion of the final MCNP model by void geometries. McCad has been used to convert a 40 deg. ITER torus sector CAD model to a suitable MCNP geometry model. Results of MCNP calculations performed to validate the converted geometry are presented

  17. AutoCAD 2014 for dummies

    CERN Document Server

    Fane, Bill

    2013-01-01

    Find your way around AutoCAD 2014 with this full-color, For Dummies guide!Put away that pencil and paper and start putting the power of AutoCAD 2014 to work in your CAD projects and designs. From setting up your drawing environment to using text, dimensions, hatching, and more, this guide walks you through AutoCAD basics and provides you with a solid understanding of the latest CAD tools and techniques. You'll also benefit from the full-color illustrations that mirror exactly what you'll see on your AutoCAD 2014 screen and highlight the importance of AutoCAD's Mode

  18. In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems.

    Science.gov (United States)

    Hamza, Tamer A; Sherif, Rana M

    2017-06-01

    Dental laboratories use different computer-aided design and computer-aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of ×100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (α=.05). The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (±SD) highest marginal discrepancy was recorded in group TZI at 39.3 ±2.3 μm, while the least mean marginal discrepancy was recorded in group IZ (22.8 ±8.9 μm). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested (Pmarginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Learning Auto CAD 2004

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-15

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  20. Learning Auto CAD 2004

    International Nuclear Information System (INIS)

    Shin, Gyeong Su; Song, Chun Dong; Park, Hyeong Jin; Kim, Yeong Min

    2004-02-01

    This book introduces basic knowledge of AutoCAD, practice method of command of AutoCAD like poly line, rotate, copy, break, trim, stretch, lengthen, chamfer, grips, extend, array polygon, spline, hatch, and image, writing letters, making library, application of design center and tool palette, drawing floor plan elevation, cross-sectional diagram, presentation materials, effective application of AutoCAD, and construction design using CAD POWER 2004.

  1. AutoCAD 2008 for dummies

    CERN Document Server

    Byrnes, David

    2007-01-01

    A gentle, humorous introduction to this fearsomely complex software that helps new users start creating 2D and 3D technical drawings right awayCovers the new features and enhancements in the latest AutoCAD version and provides coverage of AutoCAD LT, AutoCAD''s lower-cost siblingTopics covered include creating a basic layout, using AutoCAD DesignCenter, drawing and editing, working with dimensions, plotting, using blocks, adding text to drawings, and drawing on the InternetAutoCAD is the leading CAD software for architects, engineers, and draftspeople who need to create detailed 2D and 3D tech

  2. AutoCAD platform customization user interface, AutoLISP, VBA, and beyond

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Take control of AutoCAD to boost the speed, quality, and precision of your work Senior drafters and savvy users are increasingly taking AutoCAD customization out of the hands of system administrators, and taking control of their own workflow. In AutoCAD Platform Customization, Autodesk customization guru Lee Ambrosius walks you through a multitude of customization options using detailed tutorials and real-world examples applicable to AutoCAD, AutoCAD LT, Civil 3D, Plant 3D, and other programs built on the AutoCAD platform. By unleashing the full power of the software, you'll simplify and str

  3. Translucency of zirconia copings made with different CAD/CAM systems.

    Science.gov (United States)

    Baldissara, Paolo; Llukacej, Altin; Ciocca, Leonardo; Valandro, Felipe L; Scotti, Roberto

    2010-07-01

    Zirconia cores are reported to be less translucent than glass, lithium disilicate, or alumina cores. This could affect the esthetic appearance and the clinical choices made when using zirconia-based restorations. The purpose of this in vitro study was to evaluate the translucency of zirconia copings for single crowns fabricated using different CAD/CAM systems, using lithium disilicate glass ceramic as a control. Using impressions made from a stainless steel complete-crown master die, 9 stone cast replicas were fabricated, numbered, and distributed into 8 ceramic ZrO(2) CAD/CAM system groups (Lava Frame 0.3 and 0.5, IPS e.max ZirCAD, VITA YZ, Procera AllZircon, Digizon, DC Zircon, and Cercon Base) and to a lithium disilicate glass-ceramic control group (IPS e.max Press) using a simple computer-generated randomization method. From each die, the manufacturer's authorized milling centers supplied 5 copings per group without applying any dying technique to the ceramic base material. The copings were prepared to allow for a 40-mum cement layer and were of different thicknesses according to system specifications. Translucency was measured by the direct transmission method with a digital photoradiometer mounted in a dark chamber. The light source was a 150-W halogen lamp beam. Measurements were repeated 3 times for each specimen. Data obtained were analyzed using 1-way ANOVA and the Bonferroni multiple comparison test (alpha=.05). Among ZrO(2) copings, Lava (0.3 mm and 0.5 mm thick) showed the highest (Plight flow units (3.572 + or - 018 x 10(3) lx and 3.181 + or - 0.13 x 10(3) lx, respectively). These values represent 71.7% and 63.9%, respectively, of the glass-ceramic control group (4.98 x 10(3) lx). All ZrO(2) copings demonstrated different levels of light transmission, with the 2 Lava specimens showing the highest values. Translucency of zirconia copings was significantly lower (P=.001) than that of the lithium disilicate glass-ceramic control. Copyright 2010 The

  4. Application of Auto CAD 2000

    International Nuclear Information System (INIS)

    Kim, Hyeong Jun

    1999-11-01

    This book deals with basic of AutoCAD, beginning AutoCAD 2000, using design center of AutoCAD 2000, adding drawing element with design center, drawing lines, using 2D edit command, making layer, hatching, dimensioning, entering letters on the floor plan, making 3D object, practice of 3D command, edition of 3D object, making solid, rendering object, and using internet in AutoCAD 2000. This book is introduction of AutoCAD 2000 for beginner.

  5. AutoCAD 2010 For Dummies

    CERN Document Server

    Byrnes, David

    2009-01-01

    AutoCAD is the hot computer-aided design software known for both its powerful tools and its complexity. AutoCAD 2010 for Dummies is the bestselling guide that walks you through this complicated program so you can build complex 3D technical drawings, edit like a pro, enter new dimensions, and plot with style. AutoCAD 2010 for Dummies helps you navigate the program, use the AutoCAD Design Center, create a basic layout and work with dimension, and put your drawings on the Internet. You'll soon be setting up the AutoCAD environment, using the AutoCAD Ribbon, creating annotation and dimension drawi

  6. A Step-by-Step Conservative Approach for CAD-CAM Laminate Veneers

    Directory of Open Access Journals (Sweden)

    Gerardo Durán Ojeda

    2017-01-01

    Full Text Available The use of CAD/CAM technology has allowed the fabrication of ceramic restorations efficiently and with predictable results. Lithium disilicate is a type of glass ceramic material that can be used for the elaboration of laminate veneers, being monolithic restorations which require characterization through a covering ceramic in order to achieve acceptable esthetic results. The next case report shows a predictable clinical protocol for the rehabilitation of the anterior teeth through the preparation of CAD/CAM veneers (e.max CAD, Ivoclar Vivadent, Liechtenstein which have been characterized by a nanofluorapatite ceramic (e.max Ceram, Ivoclar Vivadent, Liechtenstein through the layering technique.

  7. Front panel engineering with CAD simulation tool

    Science.gov (United States)

    Delacour, Jacques; Ungar, Serge; Mathieu, Gilles; Hasna, Guenther; Martinez, Pascal; Roche, Jean-Christophe

    1999-04-01

    THe progress made recently in display technology covers many fields of application. The specification of radiance, colorimetry and lighting efficiency creates some new challenges for designers. Photometric design is limited by the capability of correctly predicting the result of a lighting system, to save on the costs and time taken to build multiple prototypes or bread board benches. The second step of the research carried out by company OPTIS is to propose an optimization method to be applied to the lighting system, developed in the software SPEOS. The main features of the tool requires include the CAD interface, to enable fast and efficient transfer between mechanical and light design software, the source modeling, the light transfer model and an optimization tool. The CAD interface is mainly a prototype of transfer, which is not the subjects here. Photometric simulation is efficiently achieved by using the measured source encoding and a simulation by the Monte Carlo method. Today, the advantages and the limitations of the Monte Carlo method are well known. The noise reduction requires a long calculation time, which increases with the complexity of the display panel. A successful optimization is difficult to achieve, due to the long calculation time required for each optimization pass including a Monte Carlo simulation. The problem was initially defined as an engineering method of study. The experience shows that good understanding and mastering of the phenomenon of light transfer is limited by the complexity of non sequential propagation. The engineer must call for the help of a simulation and optimization tool. The main point needed to be able to perform an efficient optimization is a quick method for simulating light transfer. Much work has been done in this area and some interesting results can be observed. It must be said that the Monte Carlo method wastes time calculating some results and information which are not required for the needs of the simulation

  8. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  9. Importance Of Fashion Cad Computer Aided Design Study For Garment Industry In Bangladesh..

    Directory of Open Access Journals (Sweden)

    Md. Tabraz

    2017-10-01

    Full Text Available The garment industry is rapidly growing with new concepts for keeping fashion business alive. To survive in the fashion industry new innovations are necessary for a while. In order to meet the demands for the market a computer-aided design CAD system gives opportunity for mass customization in fashion. The system enables to create more styles random changes make new design dimension of collection pattern generation graded size pattern marker creation and fabric cutting. By integrating the system with the processes of garment sewing test of fit and final adjustment mass customization can be realized in the apparel industry. For the manufacturers the efficiency of the supply chain can be improved by reducing human efforts costs and production time. For the customers better fittings with faster delivery stimulate the desire of purchase and enhance their satisfaction. This paper illustrates that why Fashion CAD study is important for garment industry in Bangladesh.

  10. CAD: How it works, how to use it, performance

    International Nuclear Information System (INIS)

    Regge, Daniele; Halligan, Steve

    2013-01-01

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence

  11. CAD: How it works, how to use it, performance

    Energy Technology Data Exchange (ETDEWEB)

    Regge, Daniele, E-mail: daniele.regge@ircc.it [Institute for Cancer Research and Treatment, Candiolo-Torino (Italy); Halligan, Steve, E-mail: s.halligan@ucl.ac.uk [University College Hospital London, London (United Kingdom)

    2013-08-15

    Computer-aided diagnosis (CAD) systems are software algorithms designed to assist radiologists (or other practitioners) in solving a diagnostic problem by using a visual prompt (or “CAD mark”) to direct the observer towards potential pathology. CT colonography is a recent arrival to CAD, but could represent one of its most fruitful applications in the future. In contrast to other organs, where a variety of different pathologies are equally represented, significant colorectal pathologies other than polyps and cancer are relatively uncommon. As we shall see, this simplifies the diagnostic task for artificial intelligence developers and also for radiologists who, ultimately, must make the final decision. This review aims to present the current state-of-the-art for CAD applied to CT colonography. A brief overview of the technical essentials and of the diagnostic performance of CAD in isolation, is followed by an explanation of how CAD is used in day-to-day practice. The last section will deal with the most controversial issues affecting CAD performance in clinical practice, with a focus on the interaction between human and artificial intelligence.

  12. Structured reporting platform improves CAD-RADS assessment.

    Science.gov (United States)

    Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; Jermendy, Ádám L; Károlyi, Mihály; Panajotu, Alexisz; Bagyura, Zsolt; Vecsey-Nagy, Milán; Cury, Ricardo C; Leipsic, Jonathon A; Merkely, Béla; Maurovich-Horvat, Pál

    2017-11-01

    Structured reporting in cardiac imaging is strongly encouraged to improve quality through consistency. The Coronary Artery Disease - Reporting and Data System (CAD-RADS) was recently introduced to facilitate interdisciplinary communication of coronary CT angiography (CTA) results. We aimed to assess the agreement between manual and automated CAD-RADS classification using a structured reporting platform. Five readers prospectively interpreted 500 coronary CT angiographies using a structured reporting platform that automatically calculates the CAD-RADS score based on stenosis and plaque parameters manually entered by the reader. In addition, all readers manually assessed CAD-RADS blinded to the automatically derived results, which was used as the reference standard. We evaluated factors influencing reader performance including CAD-RADS training, clinical load, time of the day and level of expertise. Total agreement between manual and automated classification was 80.2%. Agreement in stenosis categories was 86.7%, whereas the agreement in modifiers was 95.8% for "N", 96.8% for "S", 95.6% for "V" and 99.4% for "G". Agreement for V improved after CAD-RADS training (p = 0.047). Time of the day and clinical load did not influence reader performance (p > 0.05 both). Less experienced readers had a higher total agreement as compared to more experienced readers (87.0% vs 78.0%, respectively; p = 0.011). Even though automated CAD-RADS classification uses data filled in by the readers, it outperforms manual classification by preventing human errors. Structured reporting platforms with automated calculation of the CAD-RADS score might improve data quality and support standardization of clinical decision making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  13. User interface issues in radiotherapy CAD software. 116

    International Nuclear Information System (INIS)

    Sherouse, G.W.; Mosher, C.E. Jr.

    1987-01-01

    A major growth area in computerized planning of radiotherapy over the last five years has been the development of programs for treatment design based on the interactive graphic display of three dimensional patient models. This word has been recognized as being a close relative of Computer-Aided Design (CAD) software which is used in industry for a broad spectrum of engineering and design applications. A CAD system for radiotherapy has been constructed which combines some of the more attractive aspects of other institutions' treatment design systems with CAD technology and a user interface which is designed for use by clinicians. The importance of an appropriate user interface cannot be overemphasized and is often sadly neglected in radiotherapy software. In order to realize the potential of this new treatment design technology it is essential that clinicians, particularly physicians, perceive RT CAD systems as tools rather than as obstacles. It is felt that thhe best way to achieve that perception is for the software to implement a superset of the functions used in conventional practice while retaining the ambiance of the traditional methods. It is the aim to construct a system which an experienced physician or dosimetrist can use with essentially no retraining. The model for this CAD tool is that of a virtual simulator. It is meant to faithfully reproduce both the function and the feel of a physical simulator. A number of techniques has been identified for realizing this goal. These include simple intuitive input devices, natural coordinate systems graphic interaction, good interactive responsiveness, and high-quality 3D display modalities. Here a description of these techniques and some details of their implementation is presented. 10 refs.; 2 figs

  14. AutoCAD platform customization VBA

    CERN Document Server

    Ambrosius, Lee

    2015-01-01

    Boost productivity and streamline your workflow with expert AutoCAD: VBA programming instruction AutoCAD Platform Customization: VBA is the definitive guide to personalizing AutoCAD and the various programs that run on the AutoCAD platform, including AutoCAD Architecture, Civil 3D, Plant 3D, and more. Written by an Autodesk insider with years of customization and programming experience, this book features detailed discussions backed by real-world examples and easy-to-follow tutorials that illustrate each step in the personalization process. Readers gain expert guidance toward managing layout

  15. Evaluation of effectiveness of a computer system (CAD) in the identification of lung nodules with low-dose MSCT: scanning technique and preliminary results

    International Nuclear Information System (INIS)

    Fraioli, Francesco; Catalano, Carlo; Almberger, Maria; Bertoletti, Linda; Cantisani, Vito; Danti, Massimiliano; Pediconi, Federica; Passariello, Roberto

    2005-01-01

    Purpose: Evaluation of the effectiveness of a computer-aided diagnosis (CAD) in the identification of pulmonary nodules. Materials and methods: Two observers (A1, A2) with different levels of experience independently evaluated 20 chest MSCT studies with and without the aid of a CAD system (LungCheck, R2 Technology, Inc.). The study parameters were as follows: 140 kVs, 40 mAs, collimation 4x1 mm, slice thickness 1.25 mm, reconstruction interval 1.0 mm. The observers analysed the images with and without CAD and evaluated: 1) nodule size (longer axis); 2) number and location of nodules; 3) reading time for each observer. The gold standard was represented by the evaluation of both readers in consensus with the aid of the CAD system. Results: Without CAD support the two readers identified 77 (A1) and 79 (A2) nodules and with CAD 81 (A1) and 82 (A2) nodules. Working in consensus the two observers identified 81 nodules without the aid of CAD and 84 nodules with the aid of CAD. Total number of nodules identified by CAD was 104, 25 of which were false positive and 5 false negative. The average reading time with the aid of CAD decreased by as much as 40% for both the observers. Conclusions: The preliminary results of our study suggest that the CAD technique is an accurate automatic support tool in the identification of pulmonary nodules. It reduces reading time and automatically supplies the size, volume, density and number of nodules, thus being useful both in screening programmes and in the follow-up of cancer patients, in whom comparison of the images is particularly difficult [it

  16. AutoCAD workbook

    CERN Document Server

    Metherell, Phil

    1989-01-01

    AutoCAD Workbook helps new users learn the basics of AutoCad, providing guidance on most of the commonly used functions in which the program operates.This book discusses loading AutoCad and starting a drawing; drawing and erasing lines, circles, and arcs; and setting up the drawing environment. The topics on drawing and editing polylines; entering text and text styles; and layers, linetype, and color are also considered. This publication likewise covers creating and using blocks, hatching and extracting information, dimensioning drawings, 3D visualization, and plotting a drawing. Other

  17. MEBT design for C-ADS

    International Nuclear Information System (INIS)

    Geng Huiping; Tang Jingyu; Li Zhihui; Yan Fang; Ouyang Huafu

    2012-01-01

    In proton accelerators, the Medium Energy Beam Transport (MEBT) line is an essential part for transporting and matching the beam from the RFQ to the next type of accelerating structure. The MEBT is also very important in machine commissioning and tuning. The design of the China Accelerator Driven System is making great progress. The C-ADS project is composed of two independent injectors; therefore, two MEBT lines will be designed independently. In this paper, we will give a detailed description of the MEBT design (including parameter selection and beam dynamics calculation) for the injector I of the C-ADS project. (authors)

  18. [The CAD-S, an instrument for the assessment of adaptation to divorce - separation].

    Science.gov (United States)

    Yárnoz Yaben, Sagrario; Comino González, Priscila

    2010-02-01

    The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.

  19. Automated CD-SEM recipe creation technology for mass production using CAD data

    Science.gov (United States)

    Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru

    2011-03-01

    Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).

  20. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    Science.gov (United States)

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...this time by allowing for rapid scanning, designing , development, and production of dental restorations. Using this technology gives dentists the

  1. CAD on personal computers

    International Nuclear Information System (INIS)

    Lee, Seong U; Cho, Cheol Ho; Ko, Il Du

    1990-02-01

    This book contains four studies of CAD on personal computers. The first thing is computer graphics in computer-aided design by Seong U Lee. The second thing is graphics primer and programming with Fortran by Seong U Lee. The third thing is application of Auto cad by Il Do Ko. The last thing is application of CAD in building construction design by Cheol Ho Cho.

  2. Integrating CAD modules in a PACS environment using a wide computing infrastructure.

    Science.gov (United States)

    Suárez-Cuenca, Jorge J; Tilve, Amara; López, Ricardo; Ferro, Gonzalo; Quiles, Javier; Souto, Miguel

    2017-04-01

    The aim of this paper is to describe a project designed to achieve a total integration of different CAD algorithms into the PACS environment by using a wide computing infrastructure. The aim is to build a system for the entire region of Galicia, Spain, to make CAD accessible to multiple hospitals by employing different PACSs and clinical workstations. The new CAD model seeks to connect different devices (CAD systems, acquisition modalities, workstations and PACS) by means of networking based on a platform that will offer different CAD services. This paper describes some aspects related to the health services of the region where the project was developed, CAD algorithms that were either employed or selected for inclusion in the project, and several technical aspects and results. We have built a standard-based platform with which users can request a CAD service and receive the results in their local PACS. The process runs through a web interface that allows sending data to the different CAD services. A DICOM SR object is received with the results of the algorithms stored inside the original study in the proper folder with the original images. As a result, a homogeneous service to the different hospitals of the region will be offered. End users will benefit from a homogeneous workflow and a standardised integration model to request and obtain results from CAD systems in any modality, not dependant on commercial integration models. This new solution will foster the deployment of these technologies in the entire region of Galicia.

  3. Interoperability of CAD Standards and Robotics in CIME

    DEFF Research Database (Denmark)

    Sørensen, Torben

    The research presented in this dissertation concerns the identification of problems and provision of solutions for increasing the degree of interoperability between CAD, CACSD (Computer Aided Control Systems Design) and CAR (Computer Aided Robotics) in Computer Integrated Manufacturing and Engine......The research presented in this dissertation concerns the identification of problems and provision of solutions for increasing the degree of interoperability between CAD, CACSD (Computer Aided Control Systems Design) and CAR (Computer Aided Robotics) in Computer Integrated Manufacturing......· The development of a STEP based interface for general control system data and functions, especially related to robot motion control for interoperability of CAD, CACSD, and CAR systems for the extension of the inter-system communication capabilities beyond the stage achieved up to now.This interface development...... comprehends the following work:· The definition of the concepts of 'information' and 'information model', and the selection of a proper information modeling methodology within the STEP methodologies.· The elaboration of a general function model of a generic robot motion controller in IDEF0 for interface...

  4. Cam Design Projects in an Advanced CAD Course for Mechanical Engineers

    Science.gov (United States)

    Ault, H. K.

    2009-01-01

    The objective of this paper is to present applications of solid modeling aimed at modeling of complex geometries such as splines and blended surfaces in advanced CAD courses. These projects, in CAD-based Mechanical Engineering courses, are focused on the use of the CAD system to solve design problems for applications in machine design, namely the…

  5. Development of CAD-Based Geometry Processing Module for a Monte Carlo Particle Transport Analysis Code

    International Nuclear Information System (INIS)

    Choi, Sung Hoon; Kwark, Min Su; Shim, Hyung Jin

    2012-01-01

    As The Monte Carlo (MC) particle transport analysis for a complex system such as research reactor, accelerator, and fusion facility may require accurate modeling of the complicated geometry. Its manual modeling by using the text interface of a MC code to define the geometrical objects is tedious, lengthy and error-prone. This problem can be overcome by taking advantage of modeling capability of the computer aided design (CAD) system. There have been two kinds of approaches to develop MC code systems utilizing the CAD data: the external format conversion and the CAD kernel imbedded MC simulation. The first approach includes several interfacing programs such as McCAD, MCAM, GEOMIT etc. which were developed to automatically convert the CAD data into the MCNP geometry input data. This approach makes the most of the existing MC codes without any modifications, but implies latent data inconsistency due to the difference of the geometry modeling system. In the second approach, a MC code utilizes the CAD data for the direct particle tracking or the conversion to an internal data structure of the constructive solid geometry (CSG) and/or boundary representation (B-rep) modeling with help of a CAD kernel. MCNP-BRL and OiNC have demonstrated their capabilities of the CAD-based MC simulations. Recently we have developed a CAD-based geometry processing module for the MC particle simulation by using the OpenCASCADE (OCC) library. In the developed module, CAD data can be used for the particle tracking through primitive CAD surfaces (hereafter the CAD-based tracking) or the internal conversion to the CSG data structure. In this paper, the performances of the text-based model, the CAD-based tracking, and the internal CSG conversion are compared by using an in-house MC code, McSIM, equipped with the developed CAD-based geometry processing module

  6. AutoCAD 2012 and AutoCAD LT 2012 No Experience Required

    CERN Document Server

    Gladfelter, Donnie

    2011-01-01

    The perfect step-by-step introduction to Autodesk's powerful architectural design software With this essential guide, you'll learn how to plan, develop, document, and present a complete AutoCAD project by building a summer cabin from start to finish. You can follow each step sequentially or jump in at any point by downloading the drawing files from the book's companion web site. You'll also master all essential AutoCAD features, get a thorough grounding in the basics, learn the very latest industry standards and techniques, and quickly become productive with AutoCAD 2012.Features concise expla

  7. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  8. CAD-model based remote handling control system for NET and JET

    International Nuclear Information System (INIS)

    Leinemann, K.; Kuehneapfel, U.; Ludwig, A.

    1989-01-01

    For maintenance work in fusion plants a supervisory control system concept was developed, which organized a close, problem-suited cooperation of man and machine, based on shared control and mutual help. The central module on the task control level of the control system is a real-time simulator based on a three-dimensional CAD-model. This simulator serves for planning and of-line programming of maintenance sequences, and, in th execution phase, for integrated viewing, combining TV and synthetic scene presentation. A first implementation of a geometric simulator and its integration in an overall control system was realized for JET. (author). 5 refs.; 7 figs

  9. Computer-aided detection (CAD) in mammography: Does it help the junior or the senior radiologist?

    International Nuclear Information System (INIS)

    Balleyguier, Corinne; Kinkel, Karen; Fermanian, Jacques; Malan, Sebastien; Djen, Germaine; Taourel, Patrice; Helenon, Olivier

    2005-01-01

    Objectives: To evaluate the impact of a computer-aided detection (CAD) system on the ability of a junior and senior radiologist to detect breast cancers on mammograms, and to determine the potential of CAD as a teaching tool in mammography. Methods: Hundred biopsy-proven cancers and 100 normal mammograms were randomly analyzed by a CAD system. The sensitivity (Se) and specificity (Sp) of the CAD system were calculated. In the second phase, to simulate daily practice, 110 mammograms (97 normal or with benign lesions, and 13 cancers) were examined independently by a junior and a senior radiologist, with and without CAD. Interpretations were standardized according to BI-RADS classification. Sensitivity, Specificity, positive and negative predictive values (PPV, NPV) were calculated for each session. Results: For the senior radiologist, Se slightly improved from 76.9 to 84.6% after CAD analysis (NS) (one case of clustered microcalcifications case overlooked by the senior radiologist was detected by CAD). Sp, PPV and PNV did not change significantly. For the junior radiologist, Se improved from 61.9 to 84.6% (significant change). Three cancers overlooked by the junior radiologist were detected by CAD. Sp was unchanged. Conclusion: CAD mammography proved more useful for the junior than for the senior radiologist, improving sensitivity. The CAD system may represent a useful educational tool for mammography

  10. Vragenlijst ter beoordeling van beeldschermtekenfuncties (CAD)

    NARCIS (Netherlands)

    Berndsen, M.B.; Vaas, F.

    1990-01-01

    Deze vragenlijst is een hulpmiddel om beeldscherm-tekenfuncties (CAD) waarbij gebruik wordt gemaakt van CAD-apparatuur, te beoordelen. Het gaat hierbij om functies waarin bij de hoofdtaken intensief met een beeldscherm wordt gewerkt, zoals het geval is bij de CAD-tekenaar, de CAD-instructeur en de

  11. Evaluation of Five Microcomputer CAD Packages.

    Science.gov (United States)

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…

  12. Virtual colonoscopy: effect of computer-assisted detection (CAD) on radiographer performance

    International Nuclear Information System (INIS)

    Burling, D.; Moore, A.; Marshall, M.; Weldon, J.; Gillen, C.; Baldwin, R.; Smith, K.; Pickhardt, P.; Honeyfield, L.; Taylor, S.

    2008-01-01

    Aim: To investigate the effect of a virtual colonoscopy (VC) computed-assisted detection (CAD) system on polyp detection by trained radiographers. Materials and methods: Four radiographers trained in VC interpretation and utilization of CAD systems read a total of 62 endoscopically validated VC examinations containing 150 polyps (size range 5-50 mm) in four sessions, recording any polyps found and the examination interpretation time, first without and then with the addition of CAD as a 'second reader'. After a temporal separation of 6 weeks to reduce recall bias, VC examinations were re-read using 'concurrent reader' CAD. Interpretation times, polyp detection, and number of false-positives were compared between the different reader paradigms using paired t and paired exact tests. Results: Overall, use of 'second reader' CAD significantly improved polyp detection by 12% (p < 0.001, CI 6%,17%)) from 48 to 60%. There was no significant improvement using CAD as a concurrent reader (p = 0.20; difference of 7%, CI -3%, 16%) and no significant overall difference in recorded false-positives with second reader or concurrent CAD paradigms compared with unassisted reading (p = 0.25 and 0.65, respectively). The mean interpretation time was 21.7 min for unassisted reading, 29.6 (p < 0.001) min for second reader and 19.1 min (p = 0.12) for concurrent reading paradigms. Conclusion: CAD, when used as a second reader, can significantly improve radiographer reading performance with only a moderate increase in interpretation times

  13. Integrated electric circuit CAD system in Minolta Camera Co. Ltd

    Energy Technology Data Exchange (ETDEWEB)

    Nakagami, Tsuyoshi; Hirata, Sumiaki; Matsumura, Fumihiko

    1988-08-26

    Development background, fundamental concept, details and future plan of the integrated electric circuit CAD system for OA equipment are presented. The central integrated database is basically intended to store experiences or know-hows, to cover the wide range of data required for designs, and to provide a friendly interface. This easy-to-use integrated database covers the drawing data, parts information, design standards, know-hows and system data. The system contains the circuit design function to support drawing circuit diagrams, the wiring design function to support the wiring and arrangement of printed circuit boards and various parts integratedly, and the function to verify designs, to make full use of parts or technical information, to maintain the system security. In the future, as the system will be wholly in operation, the design period reduction, quality improvement and cost saving will be attained by this integrated design system. (19 figs, 2 tabs)

  14. Easy Korean Auto CAD 14

    International Nuclear Information System (INIS)

    Lee, Jae Cheol

    1997-10-01

    This book introduces Auto CAD 14, which includes summary of basic things of Auto CAD 14, user interface for Auto CAD, basic drawing and advice, layer and set-up drawing, drawing with Auto CAD tools exactly, basic drawing of every thing, edit command, control of display, modeling and view ports of drawing space, various things drawing, writing letters, modification of floor plan, and check, block, X ref, lines and hatch, writing measurement, floor plan and OLE exchange of data, 3D floor plan, and rendering and presentation.

  15. TinkerCell: modular CAD tool for synthetic biology

    Science.gov (United States)

    Chandran, Deepak; Bergmann, Frank T; Sauro, Herbert M

    2009-01-01

    Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD) is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API). TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at . Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled and analyzed computationally. TinkerCell can readily

  16. TinkerCell: modular CAD tool for synthetic biology

    Directory of Open Access Journals (Sweden)

    Bergmann Frank T

    2009-10-01

    Full Text Available Abstract Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API. TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at http://www.tinkercell.com. Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled

  17. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  18. Multifunctional facades - design optimisation with CAD; Multifunktionale Fassaden - Effektive Auslegung durch CAD-Einsatz

    Energy Technology Data Exchange (ETDEWEB)

    Viotto, M. [Institut fuer Solare Energieversorgungstechnik (ISET), Kassel (Germany). Abt. fuer Anlagen- und Messtechnik

    1998-02-01

    The energetically optimal design of PV facades requires the consideration of many technical conditions (different elevations/orientations of modules; shading possibility; high and different module temperatures). It also requires the interface with architecture, civil and electrical engineering. To support this planning process, the software program PV-CAD was developed which rapidly calculates energy yield under conditions of inhomogeneous irradiance, shading, thermal behaviour of modules and electrical layout. PV-CAD is compatible with other civil and electrical engineering CAD programs and incorporates extensive databases (weather data; modules and inverter types). (orig.) [Deutsch] Fuer optimalen Energieertrag sind zahlreiche technische Randbedingungen bei der Auslegung einer Photovoltaik (PV)-Fassade zu beruecksichtigen (unterschiedliche Ausrichtungen/Neigungen der Module; moegliche Teilabschattung; hoehere und unterschiedliche Betriebstemperaturen). Installation und Betrieb einer PV-Fassade erfordern die Abstimmung zwischen Architektur, Bauwesen und Elektrotechnik. Zur Unterstuetzung der Planer wurde das Programm PV-CAD entwickelt, das den Energieertrag unter Beruecksichtigung von inhomogener Einstrahlung und Abschattung, Temperaturverhalten der Fassadenmodule sowie unterschiedlichen elektrischen Anlagenkonzepten schnell ermittelt; es fuegt sich nahtlos in CAD-Arbeitsumgebungen ein. (orig.)

  19. MEASURING INFORMATION INTEGR-ATION MODEL FOR CAD/CMM

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A CAD/CMM workpiece modeling system based on IGES file is proposed. The modeling system is implemented by using a new method for labelling the tolerance items of 3D workpiece. The concept-"feature face" is used in the method. First the CAD data of workpiece are extracted and recognized automatically. Then a workpiece model is generated, which is the integration of pure 3D geometry form with its corresponding inspection items. The principle of workpiece modeling is also presented. At last, the experiment results are shown and correctness of the model is certified.

  20. Cool-and Unusual-CAD Applications

    Science.gov (United States)

    Calhoun, Ken

    2004-01-01

    This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)

  1. AutoCAD 2015 and AutoCAD LT 2015

    CERN Document Server

    Gladfelter, Donnie

    2014-01-01

    Learn AutoCAD by example with this tutorial-based guide from Autodesk Official Press Whether you are just starting out or an experienced user wanting to brush up on your skills, this Autodesk Official Press book provides you with concise explanations, focused examples, and step-by-step instructions through a hands-on tutorial project that runs throughout the book. As you progress through the project, the book introduces you to the Microsoft Windows-based AutoCAD interface and then guides you through basic commands and creating drawings. A downloadable file is available from the website so that

  2. AutoCAD 2014 essentials

    CERN Document Server

    Onstott, Scott

    2013-01-01

    Learn crucial AutoCAD tools and techniques with this Autodesk Official Press Book Quickly become productive using AutoCAD 2014 and AutoCAD LT 2014 with this full color Autodesk Official Press guide. This unique learning resource features concise, straightforward explanations and real-world, hands-on exercises and tutorials. Following a quick discussion of concepts and goals, each chapter moves on to an approachable hands-on exercise designed to reinforce real-world tactics and techniques. Compelling, full-color screenshots illustrate tutorial steps, and chapters conclude with relat

  3. Acceleration techniques for the direct use of CAD-based geometry in fusion neutronics analysis

    International Nuclear Information System (INIS)

    Wilson, Paul P.H.; Tautges, Timothy J.; Kraftcheck, Jason A.; Smith, Brandon M.; Henderson, Douglass L.

    2010-01-01

    The Direct Accelerated Geometry Monte Carlo (DAGMC) software library offers a unique approach to performing neutronics analysis on CAD-based geometries of fusion systems. By employing a number of acceleration techniques, the ray-tracing operations that are fundamental to Monte Carlo radiation transport are implemented efficiently for direct use on the CAD-based solid model, eliminating the need to translate to the native Monte Carlo input language. By forming hierarchical trees of oriented bounding boxes, one for each facet that results from a high-fidelity tessellation of the model, the ray-tracing performance is adequate to permit detailed analysis of large complex systems. In addition to the reduction in human effort and improvement in quality assurance that is found in the translation approaches, the DAGMC approach also permits the analysis of geometries with higher order surfaces that cannot be represented by many native Monte Carlo radiation transport tools. The paper describes the various acceleration techniques and demonstrates the resulting capability in a real fusion neutronics analysis.

  4. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.

    Science.gov (United States)

    Lee, Wan-Sun; Lee, Du-Hyeong; Lee, Kyu-Bok

    2017-08-01

    This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) µm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) µm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

  5. Integration of CAD and GIS technology using ArcGIS for development of building information systems

    Directory of Open Access Journals (Sweden)

    Cvetinović Jelena M.

    2014-01-01

    Full Text Available Paper will present basic definitions and significance of implementation of information systems for facility maintenance, as well as terms Facility management (FM and FM lifecycle. The main focus of this paper is on CAD and GIS integration within ArcGIS software in order to consolidate different data formats for creating unique information system for FM.

  6. BombCAD - A new tool for bomb defense in nuclear facilities

    International Nuclear Information System (INIS)

    Massa, D.J.; Howard, J.W.; Sturm, S.R.

    1988-01-01

    This paper describes a new tool for analysis of the specific vulnerability of diverse facilites to bomb attack and for computer-aided-design (CAD) of siting, screening and hardening/softening aspects of comprehensive bomb defense programs. BombCAD combines the extensive architectural and engineering data base and graphics capabilities of modern architectural CAD systems with the bomb effects computational capability of the ''SECUREPLAN'' BOMB UTILITY. BombCAD permits architects/engineers, security professionals and facility managers to analytically estimate and graphically display facility vulnerability and changes (reductions) in vulnerability which result from the adoption of various bomb defense measures

  7. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    Science.gov (United States)

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology

  8. CAD: Designs on Business.

    Science.gov (United States)

    Milburn, Ken

    1988-01-01

    Provides a general review of the field of Computer-Aided Design Software including specific reviews of "Autosketch,""Generic CADD,""Drafix 1 Plus,""FastCAD," and "Autocad Release 9." Brief articles include "Blueprint for Generation,""CAD for Every Department,""Ideas…

  9. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  10. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  11. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  12. DESIGN REVIEW OF CAD MODELS USING A NUI LEAP MOTION SENSOR

    Directory of Open Access Journals (Sweden)

    GÎRBACIA Florin

    2015-06-01

    Full Text Available Natural User Interfaces (NUI is a relatively new area of research that aims to develop humancomputer interfaces, natural and intuitive, using voice commands, hand movements and gesture recognition, similar to communication between people which also implies body language and gestures. In this paper is presented a natural designed workspace which acquires the user's motion using a Leap Motion sensor and visualizes the CAD models using a CAVE-like 3D visualisation system. The user can modify complex CAD models using bimanual gesture commands in a 3D virtual environment. The developed bimanual gestures for rotate, pan, zoom and explode are presented. From the conducted experiments is established that Leap Motion NUI sensor provides an intuitive tool for design review of CAD models, performed even by users with no experience in CAD systems and virtual environments.

  13. Toward clinically usable CAD for lung cancer screening with computed tomography

    International Nuclear Information System (INIS)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R.

    2014-01-01

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  14. Toward clinically usable CAD for lung cancer screening with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew S.; Lo, Pechin; Goldin, Jonathan G.; Barnoy, Eran; Kim, Grace Hyun J.; McNitt-Gray, Michael F.; Aberle, Denise R. [David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, CA (United States)

    2014-11-15

    The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. The test set comprised thin-section CT scans from 108 LIDC subjects. The median (±IQR) sensitivity per subject was 100 (±37.5) for nodules ≥ 4 mm and 100 (±8.33) for nodules ≥ 8 mm. The corresponding false positive rates were 0 (±2.0) and 0 (±1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality. (orig.)

  15. PTC MathCAD and Workgroup Manager: Implementation in a Multi-Org System

    Science.gov (United States)

    Jones, Corey

    2015-01-01

    In this presentation, the presenter will review what was done at Kennedy Space Center to deploy and implement PTC MathCAD and PTC Workgroup Manager in a multi-org system. During the presentation the presenter will explain how they configured PTC Windchill to create custom soft-types and object initialization rules for their custom numbering scheme and why they choose these methods. This presentation will also include how to modify the EPM default soft-type file in the PTC Windchill server codebase folder. The presenter will also go over the code used in a start up script to initiate PTC MathCAD and PTC Workgroup Manager in the proper order, and also set up the environment variables when running both PTC Workgroup Manager and PTC Creo. The configuration.ini file the presenter used will also be reviewed to show you how to set up the PTC Workgroup Manager and customized it to their user community. This presentation will be of interest to administrators trying to create a similar set-up in either a single org or multiple org system deployment. The big take away will be ideas and best practices learned through implementing this system, and the lessons learned what to do and not to do when setting up this configuration. Attendees will be exposed to several different sets of code used and that worked well and will hear some limitations on what the software can accomplish when configured this way.

  16. A wheat cinnamyl alcohol dehydrogenase TaCAD12 contributes to host resistance to the sharp eyespot disease

    Directory of Open Access Journals (Sweden)

    Wei Rong

    2016-11-01

    Full Text Available Sharp eyespot, caused mainly by the necrotrophic fungus Rhizoctonia cerealis, is a destructive disease in hexaploid wheat (Triticum aestivum L.. In Arabidopsis, certain cinnamyl alcohol dehydrogenases (CADs have been implicated in monolignol biosynthesis and in defense response to bacterial pathogen infection. However, little is known about CADs in wheat defense responses to necrotrophic or soil-borne pathogens. In this study, we isolate a wheat CAD gene TaCAD12 in response to R. cerealis infection through microarray-based comparative transcriptomics, and study the enzyme activity and defense role of TaCAD12 in wheat. The transcriptional levels of TaCAD12 in sharp eyespot-resistant wheat lines were significantly higher compared with those in susceptible wheat lines. The sequence and phylogenetic analyses revealed that TaCAD12 belongs to IV group in CAD family. The biochemical assay proved that TaCAD12 protein is an authentic CAD enzyme and possesses catalytic efficiencies towards both coniferyl aldehyde and sinapyl aldehyde. Knock-down of TaCAD12 transcript significantly repressed resistance of the gene-silenced wheat plants to sharp eyespot caused by R. cerealis, whereas TaCAD12 overexpression markedly enhanced resistance of the transgenic wheat lines to sharp eyespot. Furthermore, certain defense genes (Defensin, PR10, PR17c, and Chitinase1 and monolignol biosynthesis-related genes (TaCAD1, TaCCR, and TaCOMT1 were up-regulated in the TaCAD12-overexpressing wheat plants but down-regulated in TaCAD12-silencing plants. These results suggest that TaCAD12 positively contributes to resistance against sharp eyespot through regulation of the expression of certain defense genes and monolignol biosynthesis-related genes in wheat.

  17. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006 - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collabora- tion avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  18. Automatic generation of virtual worlds from architectural and mechanical CAD models

    International Nuclear Information System (INIS)

    Szepielak, D.

    2003-12-01

    Accelerator projects like the XFEL or the planned linear collider TESLA involve extensive architectural and mechanical design work, resulting in a variety of CAD models. The CAD models will be showing different parts of the project, like e.g. the different accelerator components or parts of the building complexes, and they will be created and stored by different groups in different formats. A complete CAD model of the accelerator and its buildings is thus difficult to obtain and would also be extremely huge and difficult to handle. This thesis describes the design and prototype development of a tool which automatically creates virtual worlds from different CAD models. The tool will enable the user to select a required area for visualization on a map, and then create a 3D-model of the selected area which can be displayed in a web-browser. The thesis first discusses the system requirements and provides some background on data visualization. Then, it introduces the system architecture, the algorithms and the used technologies, and finally demonstrates the capabilities of the system using two case studies. (orig.)

  19. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  20. Evaluation of Shipbuilding CAD/CAM/CIM Systems - Phase II (Requirements for Future Systems)

    National Research Council Canada - National Science Library

    Horvath, John; Ross, Jonathan M

    1997-01-01

    .... The purpose of the analysis was two fold: 1. To describe the requirements of a competitive, future-oriented computer-aided design/computer-aided manufacturing/computer-integrated management (CAD/CAMYCIM...

  1. Implications of unchanged detection criteria with CAD as second reader of mammograms

    International Nuclear Information System (INIS)

    Bornefalk, Hans

    2006-01-01

    In this paper we address the use of computer-aided detection (CAD) systems as second readers in mammography. The approach is based on Bayesian decision theory and its implication for the choice of optimal operating points. The choice of a certain operating point along an ROC curve corresponds to a particular tradeoff between false positives and missed cancers. By minimizing a total risk function given this tradeoff, we determine optimal decision thresholds for the radiologist and CAD system when CAD is used as a second reader. We show that under very general circumstances, the performance of the sequential system is improved if the decision threshold of the latent human decision variable is increased compared to what it would have been in the absence of the CAD system. This means that an initial stricter decision criterion should be applied by the radiologist when CAD is used as a second reader than otherwise. First and foremost, the results in this paper should be interpreted qualitatively, but an attempt is made at quantifying the effect by tuning the model to a prospective study evaluating the use of CAD as a second reader. By making some necessary and plausible assumptions, we are able to estimate the effect of the resulting suboptimal operating point. In this study of 12 860 women, we estimate that a 15% reduction in callbacks for masses could have been achieved with only about a 1.5% relative decrease in sensitivity compared to that without using a stricter initial criterion by the radiologist. For microcalcifications the corresponding values are 7% and 0.2%

  2. Particle tracking in sophisticated CAD models for simulation purposes

    International Nuclear Information System (INIS)

    Sulkimo, J.; Vuoskoski, J.

    1995-01-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT. (orig.)

  3. Particle tracking in sophisticated CAD models for simulation purposes

    Science.gov (United States)

    Sulkimo, J.; Vuoskoski, J.

    1996-02-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT.

  4. Fra form-Z til AutoCad

    DEFF Research Database (Denmark)

    Jensen, Henrik

    2003-01-01

    Dette kursus er lavet for at forberede de studerende til deres tegnestuepraktik, og dets indhold er planlagt i samarbejde med tegnestuerne. I 2003 var form-Z Arkitektskolens grundlæggende CAD-program; men på tegnestuerne arbejde man med AutoCad. Kurset er opbygget over CAD Clasic skabelonen (se min...

  5. The Role of CAD in Enterprise Integration Process

    Directory of Open Access Journals (Sweden)

    M. Ota

    2004-01-01

    Full Text Available This article deals with the problem of the mutual influence between software systems used in enterprise environment and enterprise integration processes. The position of CAD data and CAx systems in the integrated environment of manufacturing enterprises is clarified. As a consequence, the key role of CAx systems used in those companies is emphasized. It is noted that the integration of CAD data is nowadays only on a secondary level, via primarily integrated PDM systems. This limitation is a reason why we are developing a unified communication model focused on product-oriented data. Our approach is based on Internet technologies, so we believe that is independent enough. The proposed system of communication is based on a simple request-replay dialogue. The structure of this model is open and extensible, but we assume supervision supported by an Internet portal.

  6. Laboratory Performance of Universal Adhesive Systems for Luting CAD/CAM Restorative Materials.

    Science.gov (United States)

    Siqueira, Fabiana; Cardenas, Andres Millan; Gutierrez, Mario Felipe; Malaquias, Pâmela; Hass, Viviane; Reis, Alessandra; Loguercio, Alessandro D; Perdigão, Jorge

    To evaluate the microshear bond strength (μSBS) of several universal adhesive systems applied on five different indirect restorative materials. Five CAD/CAM materials were selected: 1) indirect resin composite (LAV); 2) feldspathic glass ceramic (VTR); 3) leucite-reinforced glass-ceramic (EMP); 4) lithium disilicate ceramic (EMX); 5) yttrium-stabilized zirconium dioxide (CZI). For each material, 15 blocks were cut into 4 rectangular sections (6 × 6 × 6 mm) (n = 60 per group), and processed as recommended by the respective manufacturer. For each indirect material, the following adhesive systems were applied according to the respective manufacturer's instructions: 1) AdheSE Universal [ADU]; 2) All-Bond Universal (ABU); 3) Ambar Universal (AMB); 4) Clearfil Universal (CFU); 5) Futurabond U (FBU); 6) One Coat 7 Universal (OCU); 7) Peak Universal Bond (PUB); 8) Prime&Bond Elect (PBE); 9) Scotchbond Universal Adhesive (SBU); 10) Xeno Select (XEN, negative control). After the application of the adhesive system, cylinder-shaped transparent matrices were filled with a dual-curing resin cement (NX3) and light cured. Specimens were stored in water (37°C for 24 h) and tested in shear mode at 1.0 mm/min (mSBS). The failure pattern and μSBS were statistically evaluated (a = 0.05). LAV, VTR, and EMP showed a greater number of cohesive fractures than EMX and CZI (p materials. There was a wide variability in mean μSBS when different universal adhesives were applied to the several CAD/CAM indirect materials. Most universal adhesives bonded well to air-abraded zirconia.

  7. Suunnitteluautomaatio CAD-ohjelmissa

    OpenAIRE

    Anttila, Juho

    2010-01-01

    Tässä työssä tutkittiin suunnitteluautomaation mahdollisuuksia cad-ohjelmissa. Työtä varten perehdyttiin useampaan cad-ohjelmaan ja tehtiin suurehko automaatti Vertex G4 alustalle, jonka kokemuksiin työn pohdinta pitkälti perustuu. Työ etenee yleisestä työkalujen esittelystä automatisoinnin teoriaan. Teoriassa pohditaan erilaisia tapoja ja tasoja miten automatisointia voidaan toteuttaa. Työn aihe oli kiinnostava, koska aiheesta on tehty melko vähän teoksia. Teoriapohdiskelun ohella esitettii...

  8. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006

    - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium, Bât 593 Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collaboration avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  9. The evaluation of multi-structure, multi-atlas pelvic anatomy features in a prostate MR lymphography CAD system

    Science.gov (United States)

    Meijs, M.; Debats, O.; Huisman, H.

    2015-03-01

    In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.

  10. A voxel visualization and analysis system based on AutoCAD

    Science.gov (United States)

    Marschallinger, Robert

    1996-05-01

    A collection of AutoLISP programs is presented which enable the visualization and analysis of voxel models by AutoCAD rel. 12/rel. 13. The programs serve as an interactive, graphical front end for manipulating the results of three-dimensional modeling software producing block estimation data. ASCII data files describing geometry and attributes per estimation block are imported and stored as a voxel array. Each voxel may contain multiple attributes, therefore different parameters may be incorporated in one voxel array. Voxel classification is implemented on a layer basis providing flexible treatment of voxel classes such as recoloring, peeling, or volumetry. A versatile clipping tool enables slicing voxel arrays according to combinations of three perpendicular clipping planes. The programs feature an up-to-date, graphical user interface for user-friendly operation by non AutoCAD specialists.

  11. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  12. 64006 CAD i Byggesektoren. Grundkursus

    DEFF Research Database (Denmark)

    Borchersen, Egil

    1998-01-01

    Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes.......Overview on Computer Aided Design in Civil Engineering and introduction to AutoCAD version 13, layers, colours, blocks, attributes....

  13. CAD for cutting head exchange of roadheader

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Z.; Wu, Z.; Qian, P. [China Coal Research Institute (China). Shanghai Branch

    1999-08-01

    Improving the cutting method according to the actual operating conditions is an effective way to raise production efficiency. A cutting head designed by means of computer and CAD software is characterized by short design cycle but high design quality. Taking the AM-50 road header as an example, this paper shows that it is feasible to design an interchangeable cutting head for the machine without interfering with the main technical parameters. 2 refs., 5 figs., 1 tab.

  14. AutoCAD platform customization user interface and beyond

    CERN Document Server

    Ambrosius, Lee

    2014-01-01

    Make AutoCAD your own with powerful personalization options Options for AutoCAD customization are typically the domain of administrators, but savvy users can perform their own customizations to personalize AutoCAD. Until recently, most users never thought to customize the AutoCAD platform to meet their specific needs, instead leaving it to administrators. If you are an AutoCAD user who wants to ramp up personalization options in your favorite software, AutoCAD Platform Customization: User Interface and Beyond is the perfect resource for you. Author Lee Ambrosius is recognized as a leader in Au

  15. Is the application of CAD useful for radiologists for passing the official tests required for outpatient breast imaging?

    International Nuclear Information System (INIS)

    Malich, A.; Beier, A.; Gorna, R.; Bank, P.

    2007-01-01

    Purpose: to analyze whether currently available CAD systems meet the diagnostic requirements for passing screening tests (first reader CAD) and to analyze whether the additional usage of CAD systems provides significant support for the diagnosing radiologist on the basis of official screening test cases (second reading by CAD). Material and methods: 200 images of 100 mammographies of 50 patients of an official screening test case collection were analyzed double-blind with and without CAD printouts (iCAD, U.S.A.) by three radiologists: one experienced in breast analysis and CAD application, one experienced in mammography analysis but inexperienced in CAD usage, one with minimal experience with breast analysis and CAD application. All radiologists measured the largest diameter of any malignant mass. The mean value of these calculations was correlated to the largest diameter given by CAD prompts. Results: the mean sensitivity and specificity increased slightly as a result of the additional usage of CAD (1 and 0.6%, resp.). Both values are not statistically significant. The highest effect was measured for the radiologist with CAD experience, while no effect was measured for the inexperienced radiologist. CAD met the sensitivity requirements but not the specificity criteria (96 and 20.3%, resp.). The sizes given by CAD prompts corresponded significantly with the real sizes (r = 0.45, p < 0.05). (orig.)

  16. A convertor and user interface to import CAD files into worldtoolkit virtual reality systems

    Science.gov (United States)

    Wang, Peter Hor-Ching

    1996-01-01

    Virtual Reality (VR) is a rapidly developing human-to-computer interface technology. VR can be considered as a three-dimensional computer-generated Virtual World (VW) which can sense particular aspects of a user's behavior, allow the user to manipulate the objects interactively, and render the VW at real-time accordingly. The user is totally immersed in the virtual world and feel the sense of transforming into that VW. NASA/MSFC Computer Application Virtual Environments (CAVE) has been developing the space-related VR applications since 1990. The VR systems in CAVE lab are based on VPL RB2 system which consists of a VPL RB2 control tower, an LX eyephone, an Isotrak polhemus sensor, two Fastrak polhemus sensors, a folk of Bird sensor, and two VPL DG2 DataGloves. A dynamics animator called Body Electric from VPL is used as the control system to interface with all the input/output devices and to provide the network communications as well as VR programming environment. The RB2 Swivel 3D is used as the modelling program to construct the VW's. A severe limitation of the VPL VR system is the use of RB2 Swivel 3D, which restricts the files to a maximum of 1020 objects and doesn't have the advanced graphics texture mapping. The other limitation is that the VPL VR system is a turn-key system which does not provide the flexibility for user to add new sensors and C language interface. Recently, NASA/MSFC CAVE lab provides VR systems built on Sense8 WorldToolKit (WTK) which is a C library for creating VR development environments. WTK provides device drivers for most of the sensors and eyephones available on the VR market. WTK accepts several CAD file formats, such as Sense8 Neutral File Format, AutoCAD DXF and 3D Studio file format, Wave Front OBJ file format, VideoScape GEO file format, Intergraph EMS stereolithographics and CATIA Stereolithographics STL file formats. WTK functions are object-oriented in their naming convention, are grouped into classes, and provide easy C

  17. SPLPKG WFCMPR WFAPPX, Wilson-Fowler Spline Generator for Computer Aided Design And Manufacturing (CAD/CAM) Systems

    International Nuclear Information System (INIS)

    Fletcher, S.K.

    2002-01-01

    1 - Description of program or function: The three programs SPLPKG, WFCMPR, and WFAPPX provide the capability for interactively generating, comparing and approximating Wilson-Fowler Splines. The Wilson-Fowler spline is widely used in Computer Aided Design and Manufacturing (CAD/CAM) systems. It is favored for many applications because it produces a smooth, low curvature fit to planar data points. Program SPLPKG generates a Wilson-Fowler spline passing through given nodes (with given end conditions) and also generates a piecewise linear approximation to that spline within a user-defined tolerance. The program may be used to generate a 'desired' spline against which to compare other Splines generated by CAD/CAM systems. It may also be used to generate an acceptable approximation to a desired spline in the event that an acceptable spline cannot be generated by the receiving CAD/CAM system. SPLPKG writes an IGES file of points evaluated on the spline and/or a file containing the spline description. Program WFCMPR computes the maximum difference between two Wilson-Fowler Splines and may be used to verify the spline recomputed by a receiving system. It compares two Wilson-Fowler Splines with common nodes and reports the maximum distance between curves (measured perpendicular to segments) and the maximum difference of their tangents (or normals), both computed along the entire length of the Splines. Program WFAPPX computes the maximum difference between a Wilson- Fowler spline and a piecewise linear curve. It may be used to accept or reject a proposed approximation to a desired Wilson-Fowler spline, even if the origin of the approximation is unknown. The maximum deviation between these two curves, and the parameter value on the spline where it occurs are reported. 2 - Restrictions on the complexity of the problem - Maxima of: 1600 evaluation points (SPLPKG), 1000 evaluation points (WFAPPX), 1000 linear curve breakpoints (WFAPPX), 100 spline Nodes

  18. Viewing CAD Drawings on the Internet

    Science.gov (United States)

    Schwendau, Mark

    2004-01-01

    Computer aided design (CAD) has been producing 3-D models for years. AutoCAD software is frequently used to create sophisticated 3-D models. These CAD files can be exported as 3DS files for import into Autodesk's 3-D Studio Viz. In this program, the user can render and modify the 3-D model before exporting it out as a WRL (world file hyperlinked)…

  19. WEBSITE EXECUTION OF CAD MODULES

    Directory of Open Access Journals (Sweden)

    A. A. Lyalinsky

    2013-01-01

    Full Text Available Web-based interface of modules that are part of the computer-aided design system in microelectronics is considered. The influence of several factors (available computer  memory, maximum allowed run time, degree of homogeneity of the software on the structure of the created system is investigated. Synchronous and asynchronous variants of interaction between control and executive parts are described. References on the systems that allow an access to applications in CAD microelectronics and are based on the principles discussed in this article are given.

  20. Development of CAD implementing the algorithm of boundary elements’ numerical analytical method

    Directory of Open Access Journals (Sweden)

    Yulia V. Korniyenko

    2015-03-01

    Full Text Available Up to recent days the algorithms for numerical-analytical boundary elements method had been implemented with programs written in MATLAB environment language. Each program had a local character, i.e. used to solve a particular problem: calculation of beam, frame, arch, etc. Constructing matrices in these programs was carried out “manually” therefore being time-consuming. The research was purposed onto a reasoned choice of programming language for new CAD development, allows to implement algorithm of numerical analytical boundary elements method and to create visualization tools for initial objects and calculation results. Research conducted shows that among wide variety of programming languages the most efficient one for CAD development, employing the numerical analytical boundary elements method algorithm, is the Java language. This language provides tools not only for development of calculating CAD part, but also to build the graphic interface for geometrical models construction and calculated results interpretation.

  1. Line Generalization and AutoCAD Map

    Directory of Open Access Journals (Sweden)

    Nada Vučetić

    2001-01-01

    Full Text Available The paper offers the results of original research made on the application of AutoCAD Map in line generalisation. The differences and similarities have been found out between the Douglas-Peucker method and the method of line simplification that is incorporated in AutoCAD Map. There have been also the inaccuracies found out in AutoCAD Map manual relating to the issues of buffer width and tolerance, and the line width before and after simplification. The paper gives recommendations about pseudo nodes dissolving. It has been noticed that AutoCAD Map simplification method is not independent of the order of points. The application of the method is illustrated by an example of coastal line of Istria.

  2. On CAD-integrated Structural Topology and Design Optimization

    DEFF Research Database (Denmark)

    Olhoff, Niels; Bendsøe, M.P.; Rasmussen, John

    1991-01-01

    Concepts underlying an interactive CAD-based engineering design optimization system are developed, and methods of optimizing the topology, shape and sizing of mechanical components are presented. These methods are integrated in the system, and the method for determining the optimal topology is used...

  3. GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries

    Science.gov (United States)

    Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh

    2018-04-01

    Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.

  4. Analysis of HOM Problems in the C-ADS Main Linac

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Burn [Chinese Academy of Sciences (CAS), Lanzhou (China). Inst. of Modern Physics; Ng, King Yuen [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-05-18

    Excitation of higher-order modes (HOMs) in superconducting cavities may severely affect the operation of the main linac in the Chinese Accelerator Driven System (CADS). Preliminary analysis is made on the effects of beam dynamic, which includes possible longitudinal and transverse emittance enlargements, as well as the possibility of beam breakup. Suggestions are given for further investigation. Comparison is made between the C-ADS and the Fermilab Project X.

  5. Structural and Functional Analysis of the Signal-Transducing Linker in the pH-Responsive One-Component System CadC of Escherichia coli.

    Science.gov (United States)

    Buchner, Sophie; Schlundt, Andreas; Lassak, Jürgen; Sattler, Michael; Jung, Kirsten

    2015-07-31

    The pH-responsive one-component signaling system CadC in Escherichia coli belongs to the family of ToxR-like proteins, whose members share a conserved modular structure, with an N-terminal cytoplasmic winged helix-turn-helix DNA-binding domain being followed by a single transmembrane helix and a C-terminal periplasmic pH-sensing domain. In E. coli CadC, a cytoplasmic linker comprising approximately 50 amino acids is essential for transmission of the signal from the sensor to the DNA-binding domain. However, the mechanism of transduction is poorly understood. Using NMR spectroscopy, we demonstrate here that the linker region is intrinsically disordered in solution. Furthermore, mutational analyses showed that it tolerates a range of amino acid substitutions (altering polarity, rigidity and α-helix-forming propensity), is robust to extension but is sensitive to truncation. Indeed, truncations either reversed the expression profile of the target operon cadBA or decoupled expression from external pH altogether. CadC dimerizes via its periplasmic domain, but light-scattering analysis provided no evidence for dimerization of the isolated DNA-binding domain, with or without the linker region. However, bacterial two-hybrid analysis revealed that CadC forms stable dimers in a stimulus- and linker-dependent manner, interacting only at pHpH. Thus, we propose that the disordered CadC linker is required for transducing the pH-dependent response of the periplasmic sensor into a structural rearrangement that facilitates dimerization of the cytoplasmic CadC DNA-binding domain. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Frequency of coronary artery disease (cad) risk factors in armed forces

    International Nuclear Information System (INIS)

    Kamran, S.M.; Iftikhar, R.; Abbasi, K.

    2015-01-01

    To determine the frequency of risk factors of coronary artery disease (CAD) in apparently healthy soldiers of Pakistan Armed Forces. Study Design: Cross sectional descriptive study. Place and Duration of Study: Department of medicine, CMH Okara from July 2012 to Dec 2012. Patients and Methods: The study included 2215 male currently serving soldiers in age range of 18 to 52 years by consecutive sampling. Relevant history, body mass index (BMI), waist circumference (WC) and blood pressure (BP) of each subject were recorded. BMI > 25 kg/m/sup 2/ and WC > 90 cm was considered obesity and abdominal obesity respectively. BP > 140/90 mmHg was defined as hypertension. All the participants of study underwent blood glucose fasting, blood glucose random, ECG recording, personality assessment and lipid profile. Risk estimation was done using Eric Brittain scoring system. Results: In our study group 95.5% patients were having at least 1 risk factor of CAD, 54 % were having 2 to 4 risk factors while 3.93% had > 4 risk factors. Risk estimation of CAD using Eric Brittain scoring system showed that a large proportion of study group had high probability of developing ischemic heart disease in next 6 years. Conclusion: A large proportion of our soldiers are harboring risk of CAD due to increase in frequency of 8 conventional CAD risk factors especially obesity. (author)

  7. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  8. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network.

    Science.gov (United States)

    Albero, Alberto; Pascual, Agustín; Camps, Isabel; Grau-Benitez, María

    2015-10-01

    The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems. In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured. IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials. The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness.

  9. CAD Skills Increased through Multicultural Design Project

    Science.gov (United States)

    Clemons, Stephanie

    2006-01-01

    This article discusses how students in a college-entry-level CAD course researched four generations of their family histories and documented cultural and symbolic influences within their family backgrounds. AutoCAD software was then used to manipulate those cultural and symbolic images to create the design for a multicultural area rug. AutoCAD was…

  10. Use of Cad Systems in Testing the Collision of Underground Transportation Means / Zastosowanie systemów Cad w badaniach kolizyjności środków transportu podziemnego

    Science.gov (United States)

    Dudek, Marek

    2013-06-01

    A concept of use of CAD systems in testing collision of underground transportation means is presented. Reasons for undertaking this problem are given with end users identified. The concept of the system for collision analyses of transported loads is described. Examples of collision analysis during transportation of powered roof support are given. Presented system is designed to aid planning, organizational and training activities undertaken in management of transportation safety in mines. It will be also possible to use software resources, developed within the system as the didactic material as regards safe transportation process, which include hazards to the employees working in the area of transportation operations. Developed prototype of a system for testing the collision of underground transportation means was positively assessed by employees of the Coal Company, JSC - industrial partner of KOMAG. This prototype is continuously improved and adapted for commercial implementation in the selected coal mines. W pracy przedstawiono koncepcję zastosowania systemów CAD w badaniach kolizyjności środków transportu podziemnego. Określono przyczyny podjęcia tematu oraz zidentyfikowano końcowych użytkowników. Zaprezentowano koncepcję systemu do analiz kolizyjności transportowanych ładunków. Pokazano przykłady analizy kolizyjności podczas transportu sekcji obudowy zmechanizowanej. Przedstawiony system przeznaczony jest do wspomagania działań planistycznych, organizacyjnych i szkoleniowych podejmowanych w zarządzaniu bezpieczeństwem transportu w zakładach górniczych. Opracowane w ramach systemu zasoby programowe będzie można również wykorzystać jako materiał dydaktyczny z zakresu bezpieczeństwa pracy w transporcie, uwzględniający zagrożenia dla pracowników pracujących w bezpośredniej strefie prac transportowych. Opracowany prototyp systemu do badania kolizyjności środków transportu podziemnego został pozytywnie oceniony przez pracownik

  11. CADS: a FORTRAN subroutine package to aid symbolic dataflow in FORTRAN programs

    International Nuclear Information System (INIS)

    Richards, L.R.P.; Butland, A.T.D.; Symonds, A.G.

    1982-07-01

    The Core Allocation and Dataflow System, CADS, consists of two parts, VARY and VARYIO. VARY provides a means of organising the use of data store in a program by allowing the programmer to reference and manipulate areas of data store by names of the programmer's subprogram, and therefore the complete program, to be independent of its data sources or the destination of its results. CADS therefore provides a system of symbolic dataflow. (author)

  12. The cinnamyl alcohol dehydrogenase (CAD gene family in flax (Linum usitatissimum L.: Insight from expression profiling of cads induced by elicitors in cultured flax cells

    Directory of Open Access Journals (Sweden)

    Eom Hee Seung

    2016-01-01

    Full Text Available Cinnamyl alcohol dehydrogenase (CAD is a key enzyme in the biosynthesis of lignin and lignans as it catalyzes the final step of monolignol biosynthesis, using NADPH as a cofactor. In higher plants, CAD is encoded by a multigene family consisting of three major classes. Based on the recently released flax (Linum usitatissimum L. whole-genome sequences, in this study we identified six CAD family genes that contain an ADH_N domain and an ADH_zinc_N domain, which suggests that the putative flax CADs (LuCADs are zinc-dependent alcohol dehydrogenases and members of the plant CAD family. In addition, expression analysis using quantitative real-time PCR revealed spatial variations in the expression of LuCADs in different organs. Comparative analysis between LuCAD enzymatic activity and LuCAD transcripts indicates that the variation of LuCAD enzymatic activities by elicitors is reflected by transcription of LuCADs in flax suspension-cultured cells. Taken together, our genome-wide analysis of CAD genes and the expression profiling of these genes provide valuable information for understanding the function of CADs, and will assist future studies on the physiological role of monolignols associated with plant defense.

  13. Importing CAD models into MONK and MCBEND

    International Nuclear Information System (INIS)

    Searson, K.; Fleurot, F.; Cooper, A. J.; Cowan, P.

    2009-01-01

    The direct use of Computer Aided Design (CAD) models in criticality and shielding codes has been a long standing goal for Sellafield Ltd. Such functionality could offer several advantages over the traditional method of text based modelling systems. Analysts would be able to take advantage of the advanced Graphical User Interface based modelling features provided by solid modelers, potentially reducing the costs associated with creating models in a format suitable for the analyst's criticality and shielding code. A prototype system has been developed that allows CAD models created in Autodesk Inventor or Solidworks to be used in criticality and shielding calculations. The system is based on the ANSI Initial Graphics Exchange Specification 5.3 standard and models are exported from the CAD software in Trimmed NURBS format. The format retains much more of the model's geometrical information than a format based on solid meshing techniques and avoids many of the associated problems such as large memory costs, surface approximations and void spaces. The time consuming and complex meshing process is also avoided. Runtime intersection calculations are performed using either a Bezier clipping process for NURBS based surface definitions, or by transforming the coordinate system through which the ray tracks for Surface of Revolution calculations. NURBS surfaces are therefore converted to Bezier form as the model is imported. In addition, the SR generatrix is, in general, converted to a 'strip tree' representation, allowing the SR intersection calculations to be performed with arbitrary generatrix shapes. Details of recent improvements to the Bezier clipping process are provided. Reduction in runtime of SR based Solidworks models over equivalent NURBS based Autodesk Inventor models is also demonstrated. (authors)

  14. CAD, 3D modeling, engineering analysis, and prototype experimentation industrial and research applications

    CERN Document Server

    Zheng Li, Jeremy

    2015-01-01

    This succinct book focuses on computer aided design (CAD), 3-D modeling, and engineering analysis and the ways they can be applied effectively in research and industrial sectors including aerospace, defense, automotive, and consumer products. These efficient tools, deployed for R&D in the laboratory and the field, perform efficiently three-dimensional modeling of finished products, render complex geometrical product designs, facilitate structural analysis and optimal product design, produce graphic and engineering drawings, and generate production documentation. Written with an eye toward green energy installations and novel manufacturing facilities, this concise volume enables scientific researchers and engineering professionals to learn design techniques, control existing and complex issues, proficiently use CAD tools, visualize technical fundamentals, and gain analytic and technical skills. This book also: ·       Equips practitioners and researchers to handle powerful tools for engineering desi...

  15. The building and application of a flexible CAD model for the DTU ECOCAR

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    A flexible surface model is required for CFD-optimization of the DTU ECOCAR. The report exemplifies the creation of such a model using the 3D CAD system Creo 3.0 Parametric.......A flexible surface model is required for CFD-optimization of the DTU ECOCAR. The report exemplifies the creation of such a model using the 3D CAD system Creo 3.0 Parametric....

  16. CAD-based intelligent robot system integrated with 3D scanning for shoe roughing and cementing

    Directory of Open Access Journals (Sweden)

    Chiu Cheng-Chang

    2017-01-01

    Full Text Available Roughing and cementing are very essential to the process of bonding shoe uppers and the corresponding soles; however, for shoes with complicated design, such as sport shoes, roughing and cementing greatly relied on manual operation. Recently, shoe industry is progressing to 3D design, thus 3D model of the shoe upper and sole will be created before launching into mass production. Taking advantage of the 3D model, this study developed a plug-in program on Rhino 3D CAD platform, which realized the complicated roughing and cementing route planning to be performed by the plug-in program, integrated with real-time 3D scanning information to compensate the planned route, and then converted to working trajectory of robot arm to implement roughing and cementing. The proposed 3D CAD-based intelligent robot arm system integrated with 3D scanning for shoe roughing and cementing is realized and proved to be feasible.

  17. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    Science.gov (United States)

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p manufacture of four-unit FDPs.

  18. Peningkatan Prestasi Belajar CAD Mahasiswa Teknik Otomotif Non-Reguler FT UNY melalui Pembuatan “Pohon Kata” Perintah dalam Program AutoCAD

    Directory of Open Access Journals (Sweden)

    Martubi Martubi

    2010-05-01

    Full Text Available Penelitian ini bertujuan meningkatkan prestasi belajar mata kuliah Computer Aided Design (CAD mahasiswa prodi Teknik Otomotif Non-Reguler yang dinyatakan dalam bentuk rerata nilai akhir semester yang berasal dari komponen nilai tugas harian, nilai ujian tengah semester dan nilai ujian akhir semester. Penelitian quasi-eksperimen ini terdiri dari tahapan penelitian diawali dengan penyusunan materi pembelajaran sejumlah pokok bahasan tertentu dalam satu job sheet (lembar kerja, dilanjutkan dengan pembuatan bantuan “Pohon Kata” perintah dalam Auto CAD kepada kelas eksperimen yang ditentukan secara random dari dua kelas peserta kuliah Auto CAD pada Semester Genap 2008/2009. Kedua kelas diamati prestasinya, baik kecepatan penyelesaiannya maupun kualitas kebenaran gambarnya. Prestasi belajar kedua kelas juga diukur melalui pemberian ujian tengah semester dan ujian akhir semester. Setelah data prestasi kedua kelas terkumpul dilanjutkan dengan analisis statistik melalui uji beda (t-test setelah sebelumnya dilakukan uji persyaratan analisis yang ternyata dapat dipenuhi. Hasil penelitian ini disimpulkan bahwa: prestasi belajar CAD mahasiswa pada kelas yang diberi perlakuan strategi pembelajaran menggunakan “Pohon Kata” perintah dalam Program Auto CAD lebih baik dibanding prestasi belajar CAD mahasiswa pada kelas yang tidak diberi perlakuan (75,41>70,89, dengan demikian pembelajaran CAD menggunakan media “Pohon Kata” perintah dalam Program Auto CAD dapat meningkatkan prestasi belajar mahasiswa Teknik Otomotif Program Non-Reguler.

  19. Displacement of cryomodule in CADS injector II

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Jiandong; Zhang, Bin; Wang, Fengfeng; Wan, Yuqin; Sun, Guozhen; Yao, Junjie; Zhang, Juihui; He, Yuan [Chinese Academy of Sciences, Lanzhou (China). Inst. of Modern Physics

    2017-06-15

    As Cryomodule can easily reduce higher power consumption and length of an accelerator and the accelerator can be operated more continuously. The Chinese academy of sciences institute of modern physics is developing an accelerator driven subcritical system (CADS) Injector II. Cryomodules are extremely complex systems, and their design optimization is strongly dependent on the accelerator application for which they are intended.

  20. Combining photogrammetry and CAD

    International Nuclear Information System (INIS)

    Borowsky, V.

    1993-01-01

    In nuclear power plants photogrammetry is being used to supply the data needed for setting up 3D CAD models. At Siemens, project handling has been made more economical by using photogrammetry and 3D CAD as a single process. Photogrammetry can be used for modelling extensive sections of the plant or small areas. Areas which particularly lend themselves to the use of photogrammetry are those with a high level of radiation or those yielding a large volume of data. (author)

  1. Application of Auto CAD

    International Nuclear Information System (INIS)

    Park, Yong Un; Kim, Geun Ho

    1989-05-01

    This book has introduction to use this book and explanation of application on Auto CAD, which includes, sub directories, batch files, robot wrist, design of standard paper, title block, robort weld room, robert wrist joint, PC board, plant sym, electro, PID, machines, robots, bubbles, plant, schema, Pid, plant assembly, robots, dim plant, PL-ASSM, plotting line weight control, symbol drawing joint, Auto CAD using script file, set up of workout · MNU, workout MNU, ACAD, LSP and workout · MNU.

  2. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    Science.gov (United States)

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane

  3. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  4. ELM BASED CAD SYSTEM TO CLASSIFY MAMMOGRAMS BY THE COMBINATION OF CLBP AND CONTOURLET

    Directory of Open Access Journals (Sweden)

    S Venkatalakshmi

    2017-05-01

    Full Text Available Breast cancer is a serious life threat to the womanhood, worldwide. Mammography is the promising screening tool, which can show the abnormality being detected. However, the physicians find it difficult to detect the affected regions, as the size of microcalcifications is very small. Hence it would be better, if a CAD system can accompany the physician in detecting the malicious regions. Taking this as a challenge, this paper presents a CAD system for mammogram classification which is proven to be accurate and reliable. The entire work is decomposed into four different stages and the outcome of a phase is passed as the input of the following phase. Initially, the mammogram is pre-processed by adaptive median filter and the segmentation is done by GHFCM. The features are extracted by combining the texture feature descriptors Completed Local Binary Pattern (CLBP and contourlet to frame the feature sets. In the training phase, Extreme Learning Machine (ELM is trained with the feature sets. During the testing phase, the ELM can classify between normal, malignant and benign type of cancer. The performance of the proposed approach is analysed by varying the classifier, feature extractors and parameters of the feature extractor. From the experimental analysis, it is evident that the proposed work outperforms the analogous techniques in terms of accuracy, sensitivity and specificity.

  5. Tuner control system of Spoke012 SRF cavity for C-ADS injector I

    Science.gov (United States)

    Liu, Na; Sun, Yi; Wang, Guang-Wei; Mi, Zheng-Hui; Lin, Hai-Ying; Wang, Qun-Yao; Liu, Rong; Ma, Xin-Peng

    2016-09-01

    A new tuner control system for spoke superconducting radio frequency (SRF) cavities has been developed and applied to cryomodule I of the C-ADS injector I at the Institute of High Energy Physics, Chinese Academy of Sciences. We have successfully implemented the tuner controller based on Programmable Logic Controller (PLC) for the first time and achieved a cavity tuning phase error of ±0.7° (about ±4 Hz peak to peak) in the presence of electromechanical coupled resonance. This paper presents preliminary experimental results based on the PLC tuner controller under proton beam commissioning. Supported by Proton linac accelerator I of China Accelerator Driven sub-critical System (Y12C32W129)

  6. Or CAD 9.1

    International Nuclear Information System (INIS)

    Lee, Seung Mu

    2000-02-01

    This book gives descriptions of Or CAD 9.1 with before drawing plan such as gaining Or CAD Demo CD, capture tools, making new design file, drawing structure, and setting design template, Drawings like making new drawing, finding parts, drawing lines, connecting line among the pages, and connecting parts using drawing structure, unstable multivibrator circle such as management of design file, power and ground connection, utility, beginning layout, single drawing, flat drawing, latch circuit, making a library, making a footprint, smart route and flash window.

  7. Immersive CAD

    Energy Technology Data Exchange (ETDEWEB)

    Ames, A.L.

    1999-02-01

    This paper documents development of a capability for performing shape-changing editing operations on solid model representations in an immersive environment. The capability includes part- and assembly-level operations, with part modeling supporting topology-invariant and topology-changing modifications. A discussion of various design considerations in developing an immersive capability is included, along with discussion of a prototype implementation we have developed and explored. The project investigated approaches to providing both topology-invariant and topology-changing editing. A prototype environment was developed to test the approaches and determine the usefulness of immersive editing. The prototype showed exciting potential in redefining the CAD interface. It is fun to use. Editing is much faster and friendlier than traditional feature-based CAD software. The prototype algorithms did not reliably provide a sufficient frame rate for complex geometries, but has provided the necessary roadmap for development of a production capability.

  8. CAD-based Monte Carlo program for integrated simulation of nuclear system SuperMC

    International Nuclear Information System (INIS)

    Wu, Yican; Song, Jing; Zheng, Huaqing; Sun, Guangyao; Hao, Lijuan; Long, Pengcheng; Hu, Liqin

    2015-01-01

    Highlights: • The new developed CAD-based Monte Carlo program named SuperMC for integrated simulation of nuclear system makes use of hybrid MC-deterministic method and advanced computer technologies. SuperMC is designed to perform transport calculation of various types of particles, depletion and activation calculation including isotope burn-up, material activation and shutdown dose, and multi-physics coupling calculation including thermo-hydraulics, fuel performance and structural mechanics. The bi-directional automatic conversion between general CAD models and physical settings and calculation models can be well performed. Results and process of simulation can be visualized with dynamical 3D dataset and geometry model. Continuous-energy cross section, burnup, activation, irradiation damage and material data etc. are used to support the multi-process simulation. Advanced cloud computing framework makes the computation and storage extremely intensive simulation more attractive just as a network service to support design optimization and assessment. The modular design and generic interface promotes its flexible manipulation and coupling of external solvers. • The new developed and incorporated advanced methods in SuperMC was introduced including hybrid MC-deterministic transport method, particle physical interaction treatment method, multi-physics coupling calculation method, geometry automatic modeling and processing method, intelligent data analysis and visualization method, elastic cloud computing technology and parallel calculation method. • The functions of SuperMC2.1 integrating automatic modeling, neutron and photon transport calculation, results and process visualization was introduced. It has been validated by using a series of benchmarking cases such as the fusion reactor ITER model and the fast reactor BN-600 model. - Abstract: Monte Carlo (MC) method has distinct advantages to simulate complicated nuclear systems and is envisioned as a routine

  9. True Concurrent Thermal Engineering Integrating CAD Model Building with Finite Element and Finite Difference Methods

    Science.gov (United States)

    Panczak, Tim; Ring, Steve; Welch, Mark

    1999-01-01

    Thermal engineering has long been left out of the concurrent engineering environment dominated by CAD (computer aided design) and FEM (finite element method) software. Current tools attempt to force the thermal design process into an environment primarily created to support structural analysis, which results in inappropriate thermal models. As a result, many thermal engineers either build models "by hand" or use geometric user interfaces that are separate from and have little useful connection, if any, to CAD and FEM systems. This paper describes the development of a new thermal design environment called the Thermal Desktop. This system, while fully integrated into a neutral, low cost CAD system, and which utilizes both FEM and FD methods, does not compromise the needs of the thermal engineer. Rather, the features needed for concurrent thermal analysis are specifically addressed by combining traditional parametric surface based radiation and FD based conduction modeling with CAD and FEM methods. The use of flexible and familiar temperature solvers such as SINDA/FLUINT (Systems Improved Numerical Differencing Analyzer/Fluid Integrator) is retained.

  10. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Engineering applications using CAD based application programming interface

    Directory of Open Access Journals (Sweden)

    Tzotzis Anastasios

    2017-01-01

    Full Text Available Automating the design process of a product or a system can provide engineers and designers with many benefits. As such, repeatable tasks that are time consuming can be handled automatically and with minimal human attention. This is achieved by using the API (Application Programmable Interface of CAD systems in order to create macros or even develop software applications. The present paper deals with an application that has been developed with the API of a general purposes CAD system. This application automates the design process of a standard pneumatic double acting cylinder based on the appropriate inserted parameters (ISO 15552.The design process begins with the creation of a series of components developed as solids, and extends to the extraction of basic attributes and properties from the complete mechanical assembly. Finally, the assembled models and the extracted data can be used to further study the design of the pneumatic double acting cylinder. It is expected in the future to expand the features of the presented application in order to automate the design process of other related mechanical systems.

  12. Application of CAD/CFD/RP-technologies for development of LVAD systems

    Directory of Open Access Journals (Sweden)

    Morozov Valentin

    2016-01-01

    Full Text Available The important problem of new Left Ventricle Assist Device (LVAD systems development is to determine their hemodynamic and functional characteristics and reduce the design time. An effective method for achieving this is the use of approaches based on the application of CAD/CFD/PR-technologies. Methods of computer modelling were applied to determine the geometrical parameters of the blood pump, and methods of finite element analysis were used for the optimization of hemodynamic parameters of the LVAD system. The geometrical modelling was carried out in the Pro/Engineer WF5. The CAE-system Ansys was used to analyze the blood flow in the chamber of the pump. The motion of the flexible walls was simulated by normal flow through rigid walls. At the final stage some models were prepared for prototyping. The critical parameters of hemodynamic gave the possibility to optimize the shape of the blood pump. The LVAD system and its components were made using various RP-technologies. The hydraulic tests for the performance investigation and the analysis of implantability for implantable systems were carried out for manufactured prototypes of LVAD systems. The manufactured components of the LVAD system are completely operability and give the possibility to estimate the critical hemodynamic and functional parameters of the LVAD system.

  13. rCAD: A Novel Database Schema for the Comparative Analysis of RNA.

    Science.gov (United States)

    Ozer, Stuart; Doshi, Kishore J; Xu, Weijia; Gutell, Robin R

    2011-12-31

    Beyond its direct involvement in protein synthesis with mRNA, tRNA, and rRNA, RNA is now being appreciated for its significance in the overall metabolism and regulation of the cell. Comparative analysis has been very effective in the identification and characterization of RNA molecules, including the accurate prediction of their secondary structure. We are developing an integrative scalable data management and analysis system, the RNA Comparative Analysis Database (rCAD), implemented with SQL Server to support RNA comparative analysis. The platformagnostic database schema of rCAD captures the essential relationships between the different dimensions of information for RNA comparative analysis datasets. The rCAD implementation enables a variety of comparative analysis manipulations with multiple integrated data dimensions for advanced RNA comparative analysis workflows. In this paper, we describe details of the rCAD schema design and illustrate its usefulness with two usage scenarios.

  14. AutoCAD 2014 review for certification official certification preparation

    CERN Document Server

    ASCENT center for technical knowledge

    2014-01-01

    The AutoCAD® 2014 Review for Certification book is intended for users of AutoCAD® preparing to complete the AutoCAD 2014 Certified Professional exam. This book contains a collection of relevant instructional topics, practice exercises, and review questions from the Autodesk Official Training Guides (AOTG) from ASCENT - Center for Technical Knowledge pertaining specifically to the Certified Professional exam topics and objectives. This book is intended for experienced users of AutoCAD in preparation for certification. New users of AutoCAD should refer to the AOTG training guides from ASCENT, such as AutoCAD/AutoCAD LT 2014 Fundamentals, for more comprehensive instruction.

  15. Integrated CAE system for nuclear power plants. Development of piping design check system

    International Nuclear Information System (INIS)

    Narikawa, Noboru; Sato, Teruaki

    1994-01-01

    Toshiba Corporation has developed and operated the integrated CAE system for nuclear power plants, the core of which is the engineering data base to manage accurately and efficiently enormous amount of data on machinery, equipment and piping. As the first step of putting knowledge base system to practical use, piping design check system has been developed. By automatically checking up piping design, this system aims at the prevention of overlooking mistakes, efficient design works and the overall quality improvement of design. This system is based on the thought that it supports designers, and final decision is made by designers. This system is composed of the integrated data base, a two-dimensional CAD system and three-dimensional CAD system. The piping design check system is one of the application systems of the integrated CAE system. Object-oriented programming is the base of the piping design check system, and design knowledge and CAD data are necessary. As to the method of realizing the check system, the flow of piping design, the checkup functions, the checkup of interference and attribute base, and the integration of the system are explained. (K.I)

  16. Manipulating cinnamyl alcohol dehydrogenase (CAD) expression in flax affects fibre composition and properties

    Science.gov (United States)

    2014-01-01

    Background In recent decades cultivation of flax and its application have dramatically decreased. One of the reasons for this is unpredictable quality and properties of flax fibre, because they depend on environmental factors, retting duration and growing conditions. These factors have contribution to the fibre composition, which consists of cellulose, hemicelluloses, lignin and pectin. By far, it is largely established that in flax, lignin reduces an accessibility of enzymes either to pectin, hemicelluloses or cellulose (during retting or in biofuel synthesis and paper production). Therefore, in this study we evaluated composition and properties of flax fibre from plants with silenced CAD (cinnamyl alcohol dehydrogenase) gene, which is key in the lignin biosynthesis. There is evidence that CAD is a useful tool to improve lignin digestibility and/or to lower the lignin levels in plants. Results Two studied lines responded differentially to the introduced modification due to the efficiency of the CAD silencing. Phylogenetic analysis revealed that flax CAD belongs to the “bona-fide” CAD family. CAD down-regulation had an effect in the reduced lignin amount in the flax fibre cell wall and as FT-IR results suggests, disturbed lignin composition and structure. Moreover introduced modification activated a compensatory mechanism which was manifested in the accumulation of cellulose and/or pectin. These changes had putative correlation with observed improved fiber’s tensile strength. Moreover, CAD down-regulation did not disturb at all or has only slight effect on flax plants’ development in vivo, however, the resistance against flax major pathogen Fusarium oxysporum decreased slightly. The modification positively affected fibre possessing; it resulted in more uniform retting. Conclusion The major finding of our paper is that the modification targeted directly to block lignin synthesis caused not only reduced lignin level in fibre, but also affected amount and

  17. Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD/CAM Materials.

    Science.gov (United States)

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2018-03-06

    A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p 0.05). Deviation pattern for

  18. Quantitative assessment of multiple sclerosis lesion load using CAD and expert input

    Science.gov (United States)

    Gertych, Arkadiusz; Wong, Alexis; Sangnil, Alan; Liu, Brent J.

    2008-03-01

    Multiple sclerosis (MS) is a frequently encountered neurological disease with a progressive but variable course affecting the central nervous system. Outline-based lesion quantification in the assessment of lesion load (LL) performed on magnetic resonance (MR) images is clinically useful and provides information about the development and change reflecting overall disease burden. Methods of LL assessment that rely on human input are tedious, have higher intra- and inter-observer variability and are more time-consuming than computerized automatic (CAD) techniques. At present it seems that methods based on human lesion identification preceded by non-interactive outlining by CAD are the best LL quantification strategies. We have developed a CAD that automatically quantifies MS lesions, displays 3-D lesion map and appends radiological findings to original images according to current DICOM standard. CAD is also capable to display and track changes and make comparison between patient's separate MRI studies to determine disease progression. The findings are exported to a separate imaging tool for review and final approval by expert. Capturing and standardized archiving of manual contours is also implemented. Similarity coefficients calculated from quantities of LL in collected exams show a good correlation of CAD-derived results vs. those incorporated as expert's reading. Combining the CAD approach with an expert interaction may impact to the diagnostic work-up of MS patients because of improved reproducibility in LL assessment and reduced time for single MR or comparative exams reading. Inclusion of CAD-generated outlines as DICOM-compliant overlays into the image data can serve as a better reference in MS progression tracking.

  19. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    Science.gov (United States)

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p CAD (p = 0.0115), and Lava Ultimate (p CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the

  20. Energy efficient lighting design for Venlo type greenhouses

    NARCIS (Netherlands)

    Janssen, E.G.O.N.; Zonneveldt, L.; Sools, F.

    2005-01-01

    TNO has developed a Radiance software model to calculate the light distribution in the greenhouse using raytracing methods, suitable for daylight and artificial lighting. The model is based on a 3d CAD model. The objective is to maximize the efficiency of the artificial lighting system (the amount

  1. A Robust and Fast System for CTC Computer-Aided Detection of Colorectal Lesions

    Directory of Open Access Journals (Sweden)

    Gareth Beddoe

    2010-01-01

    Full Text Available We present a complete, end-to-end computer-aided detection (CAD system for identifying lesions in the colon, imaged with computed tomography (CT. This system includes facilities for colon segmentation, candidate generation, feature analysis, and classification. The algorithms have been designed to offer robust performance to variation in image data and patient preparation. By utilizing efficient 2D and 3D processing, software optimizations, multi-threading, feature selection, and an optimized cascade classifier, the CAD system quickly determines a set of detection marks. The colon CAD system has been validated on the largest set of data to date, and demonstrates excellent performance, in terms of its high sensitivity, low false positive rate, and computational efficiency.

  2. Westinghouse Idaho Nuclear Company, Inc. (WINCO) CAD activities at the Idaho Chemical Processing Plant (ICPP) (Idaho Engineering Laboratory)

    International Nuclear Information System (INIS)

    Jensen, B.

    1989-01-01

    June 1985 -- The drafting manager obtained approval to implement a cad system at the ICPP. He formed a committee to evaluate the various cad systems and recommend a system that would most benefit the ICPP. A ''PC'' (personal computer) based system using Autocad software was recommended in lieu of the much more expensive main frame based systems

  3. CATO: a CAD tool for intelligent design of optical networks and interconnects

    Science.gov (United States)

    Chlamtac, Imrich; Ciesielski, Maciej; Fumagalli, Andrea F.; Ruszczyk, Chester; Wedzinga, Gosse

    1997-10-01

    Increasing communication speed requirements have created a great interest in very high speed optical and all-optical networks and interconnects. The design of these optical systems is a highly complex task, requiring the simultaneous optimization of various parts of the system, ranging from optical components' characteristics to access protocol techniques. Currently there are no computer aided design (CAD) tools on the market to support the interrelated design of all parts of optical communication systems, thus the designer has to rely on costly and time consuming testbed evaluations. The objective of the CATO (CAD tool for optical networks and interconnects) project is to develop a prototype of an intelligent CAD tool for the specification, design, simulation and optimization of optical communication networks. CATO allows the user to build an abstract, possible incomplete, model of the system, and determine its expected performance. Based on design constraints provided by the user, CATO will automatically complete an optimum design, using mathematical programming techniques, intelligent search methods and artificial intelligence (AI). Initial design and testing of a CATO prototype (CATO-1) has been completed recently. The objective was to prove the feasibility of combining AI techniques, simulation techniques, an optical device library and a graphical user interface into a flexible CAD tool for obtaining optimal communication network designs in terms of system cost and performance. CATO-1 is an experimental tool for designing packet-switching wavelength division multiplexing all-optical communication systems using a LAN/MAN ring topology as the underlying network. The two specific AI algorithms incorporated are simulated annealing and a genetic algorithm. CATO-1 finds the optimal number of transceivers for each network node, using an objective function that includes the cost of the devices and the overall system performance.

  4. Collaborative product development in CAD and CAPP, an approach based on communication due to constraint conflicts and user initiative

    NARCIS (Netherlands)

    Salomons, O.W.; Kuipers, J.M.; van de Graaff, J.; van Slooten, F.; van Slooten, F.; van Houten, Frederikus J.A.M.; Kals, H.J.J.

    1995-01-01

    This paper addresses collaborative product development, focusing on computer support of collaboration between users of CAD systems alone, between users of CAPP systems alone and between users of both CAD and CAPP systems. Computer support of collaborative product development may enhance informal

  5. A Knowledge Based Approach to VLSI CAD

    Science.gov (United States)

    1983-09-01

    Avail-and/or Dist ISpecial L| OI. SEICURITY CLASIIrCATION OP THIS IPA.lErllm S Daene." A KNOwLEDE BASED APPROACH TO VLSI CAD’ Louis L Steinberg and...major issues lies in building up and managing the knowledge base of oesign expertise. We expect that, as with many recent expert systems, in order to

  6. CAD/CAM/CNC.

    Science.gov (United States)

    Domermuth, Dave; And Others

    1996-01-01

    Includes "Quick Start CNC (computer numerical control) with a Vacuum Filter and Laminated Plastic" (Domermuth); "School and Industry Cooperate for Mutual Benefit" (Buckler); and "CAD (computer-assisted drafting) Careers--What Professionals Have to Say" (Skinner). (JOW)

  7. Performance and value of CAD-deficient pine- Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Bailian Li; Houmin Chang; Hasan Jameel

    2007-02-28

    The southern US produces 58% of the nation's timber, much of it grown in intensively managed plantations of genetically improved loblolly pine. One of the fastest-growing loblolly pine selections made by the NCSU-Industry Cooperative Tree Improvement Program, whose progeny are widely planted, is also the only known natural carrier of a rare gene, cadn1. This allele codes for deficiency in an enzyme, cinnamyl alcohol dehydrogenase, which catalyzes the last step in the biosynthesis of lignin precursors. This study is to characterize this candidate gene for marker-assisted selection and deployment in the breeding program. This research will enhance the sustainability of forest production in the South, where land-use pressures will limit the total area available in the future for intensively managed plantations. Furthermore, this research will provide information to establish higher-value plantation forests with more desirable wood/fiber quality traits. A rare mutant allele (cad-n1) of the cad gene in loblolly pine (Pinus taeda L.) causes a deficiency in the production of cinnamyl alcohol dehydrogenase (CAD). The effects of this allele were examined by comparing wood density and growth traits of cad-n1 heterozygous trees with those of wild-type trees in a 10-year-old open-pollinated family trial growing under two levels of fertilization in Scotland County, North Carolina. In all, 200 trees were sampled with 100 trees for each treatment. Wood density measurements were collected from wood cores at breast height using x-ray densitometry. We found that the substitution of cad-n1 for a wild-type allele (Cad) was associated with a significant effect on wood density. The cad-n1 heterozygotes had a significantly higher wood density (+2.6%) compared to wild-type trees. The higher density was apparently due to the higher percentage of latewood in the heterozygotes. The fertilization effect was highly significant for both growth and wood density traits. While no cad genotype

  8. Sharing the learning activity using intelligent CAD

    DEFF Research Database (Denmark)

    Duffy, S. M.; Duffy, Alex

    1996-01-01

    In this paper the need for Intelligent Computer Aided Design (Int.CAD) to jointly support design and learning assistance is introduced. The paper focuses on presenting and exploring the possibility of realizing ''learning'' assistance in Int.CAD by introducing a new concept called Shared Learning...

  9. Radmap: ''as-built'' cad models incorporating geometrical, radiological and material information

    International Nuclear Information System (INIS)

    Piotrowski, L.; Lubawy, J.L.

    2001-01-01

    EDF intends to achieve successful and cost-effective dismantling of its obsolete nuclear plants. To reach this goal, EDF is currently extending its ''as-built'' 3-D modelling system to also include the location and characteristics of gamma sources in the geometrical models of its nuclear installations. The resulting system (called RADMAP) is a complete CAD chain covering 3-D and gamma data acquisitions, CAD modelling and exploitation of the final model. Its aim is to describe completely the geometrical and radiological state of a particular nuclear environment. This paper presents an overall view of RADMAP. The technical and functional characteristics of each element of the chain are indicated and illustrated using real (EDF) environments/applications. (author)

  10. Automation in the Teaching of Descriptive Geometry and CAD. High-Level CAD Templates Using Script Languages

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study improvements to the learning method of technical drawing and descriptive geometry through exercises with traditional techniques that are usually solved manually by applying automated processes assisted by high-level CAD templates (HLCts). Given that an exercise with traditional procedures can be solved, detailed step by step in technical drawing and descriptive geometry manuals, CAD applications allow us to do the same and generalize it later, incorporating references. Traditional teachings have become obsolete and current curricula have been relegated. However, they can be applied in certain automation processes. The use of geometric references (using variables in script languages) and their incorporation into HLCts allows the automation of drawing processes. Instead of repeatedly creating similar exercises or modifying data in the same exercises, users should be able to use HLCts to generate future modifications of these exercises. This paper introduces the automation process when generating exercises based on CAD script files, aided by parametric geometry calculation tools. The proposed method allows us to design new exercises without user intervention. The integration of CAD, mathematics, and descriptive geometry facilitates their joint learning. Automation in the generation of exercises not only saves time but also increases the quality of the statements and reduces the possibility of human error.

  11. Coupling photon Monte Carlo simulation and CAD software. Application to X-ray nondestructive evaluation

    International Nuclear Information System (INIS)

    Tabary, J.; Gliere, A.

    2001-01-01

    A Monte Carlo radiation transport simulation program, EGS Nova, and a computer aided design software, BRL-CAD, have been coupled within the framework of Sindbad, a nondestructive evaluation (NDE) simulation system. In its current status, the program is very valuable in a NDE laboratory context, as it helps simulate the images due to the uncollided and scattered photon fluxes in a single NDE software environment, without having to switch to a Monte Carlo code parameters set. Numerical validations show a good agreement with EGS4 computed and published data. As the program's major drawback is the execution time, computational efficiency improvements are foreseen. (orig.)

  12. A methodological study on organizing an intelligent CAD/CAE system for conceptual design of advanced nuclear reactor system

    International Nuclear Information System (INIS)

    Gofuku, Akio; Yoshikawa, Hidekazu

    1993-01-01

    In order to shorten the time span of design work and enhance both consistency and rationality of design products, the authors are now investigating an intelligent CAD/CAE system to support cooperative works by many specialists by adopting object-oriented approach. In this paper, the cognitive aspect of design activities of specialists in the conceptual design phase of nuclear reactors is discussed. The activities of the specialists in their design analysis process are highly knowledge-based and goal-oriented. The characteristics of the activities are 1) hierarchization of design goal into sub-goals, 2) prioritization of design sub-goals and step-by-step practise of design analysis, and 3) abstraction of real-world space structure into more simplified space structure to cope with theoretical treatment. Based on these consideration, a conceptual design model of specialists' activities composed of attribute modeling and design expertise knowledge base is proposed. The 'principle of functional independence' proposed by Sue is applied to bridge between the attribute modeling and design expertise knowledge base. The intelligent CAD/CAE system is now under development by focusing on the conceptual design of a space power reactor core utilizing thermo-ionic fuel elements as direct thermo-to-electric conversion. A program to calculate thermo-hydraulics of reactor core and thermo-ionic power generation has been developed. An interface has been also developed in order to communicate with the specialists at JAERI by E-mail concerning the interactive calculation between our calculation and the neutronics calculation of reactor core. (orig.)

  13. A methodological study on organizing an intelligent CAD/CAE system for conceptual design of advanced nuclear reactor system

    Energy Technology Data Exchange (ETDEWEB)

    Gofuku, Akio (Inst. of Atomic Energy, Kyoto Univ. (Japan)); Yoshikawa, Hidekazu (Inst. of Atomic Energy, Kyoto Univ. (Japan))

    1993-04-01

    In order to shorten the time span of design work and enhance both consistency and rationality of design products, the authors are now investigating an intelligent CAD/CAE system to support cooperative works by many specialists by adopting object-oriented approach. In this paper, the cognitive aspect of design activities of specialists in the conceptual design phase of nuclear reactors is discussed. The activities of the specialists in their design analysis process are highly knowledge-based and goal-oriented. The characteristics of the activities are 1) hierarchization of design goal into sub-goals, 2) prioritization of design sub-goals and step-by-step practise of design analysis, and 3) abstraction of real-world space structure into more simplified space structure to cope with theoretical treatment. Based on these consideration, a conceptual design model of specialists' activities composed of attribute modeling and design expertise knowledge base is proposed. The 'principle of functional independence' proposed by Sue is applied to bridge between the attribute modeling and design expertise knowledge base. The intelligent CAD/CAE system is now under development by focusing on the conceptual design of a space power reactor core utilizing thermo-ionic fuel elements as direct thermo-to-electric conversion. A program to calculate thermo-hydraulics of reactor core and thermo-ionic power generation has been developed. An interface has been also developed in order to communicate with the specialists at JAERI by E-mail concerning the interactive calculation between our calculation and the neutronics calculation of reactor core. (orig.)

  14. Multi-site evaluation of a computer aided detection (CAD) algorithm for small acute intra-cranial hemorrhage and development of a stand-alone CAD system ready for deployment in a clinical environment

    Science.gov (United States)

    Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.

    2010-03-01

    Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.

  15. AutoCAD-To-NASTRAN Translator Program

    Science.gov (United States)

    Jones, A.

    1989-01-01

    Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).

  16. Ergonomics Perspective in Agricultural Research: A User-Centred Approach Using CAD and Digital Human Modeling (DHM) Technologies

    Science.gov (United States)

    Patel, Thaneswer; Sanjog, J.; Karmakar, Sougata

    2016-09-01

    Computer-aided Design (CAD) and Digital Human Modeling (DHM) (specialized CAD software for virtual human representation) technologies endow unique opportunities to incorporate human factors pro-actively in design development. Challenges of enhancing agricultural productivity through improvement of agricultural tools/machineries and better human-machine compatibility can be ensured by adoption of these modern technologies. Objectives of present work are to provide the detailed scenario of CAD and DHM applications in agricultural sector; and finding out means for wide adoption of these technologies for design and development of cost-effective, user-friendly, efficient and safe agricultural tools/equipment and operator's workplace. Extensive literature review has been conducted for systematic segregation and representation of available information towards drawing inferences. Although applications of various CAD software have momentum in agricultural research particularly for design and manufacturing of agricultural equipment/machinery, use of DHM is still at its infancy in this sector. Current review discusses about reasons of less adoption of these technologies in agricultural sector and steps to be taken for their wide adoption. It also suggests possible future research directions to come up with better ergonomic design strategies for improvement of agricultural equipment/machines and workstations through application of CAD and DHM.

  17. The efficacy of using CAD for detection of breast cancer in mammography screening A systematic review

    DEFF Research Database (Denmark)

    Henriksen, Emilie; Lauridsen, Carsten Ammitzbøl

    Abstract Purpose: The aim of this systematic review is to present an overview of the available studies concerning the use of computer-aided detection (CAD) systems in screening mammography for early detection of breast cancer and compare the diagnostic accuracy and recall rates of single reading....... The literature search resulted in 1522 records after duplicates were removed. 1491 records were excluded by abstract and 18 were excluded after assessing the eligibility by full text reading. A total of 13 articles were included in this study. Results: The results for the single reading vs. single reading...... with CAD group indicate that the addition of CAD increases sensitivity and cancer detection rate (CDR). For the double reading vs. single reading with CAD group none of the studies reported significant differences in sensitivity and CDR. Adding CAD to single reading increased the recall rates and decreased...

  18. Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview

    Directory of Open Access Journals (Sweden)

    Chui Ling Goo

    2017-01-01

    Full Text Available This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.

  19. Computer modeling of occlusal surfaces of posterior teeth with the CICERO CAD/CAM system.

    Science.gov (United States)

    Olthoff, L W; Van Der Zel, J M; De Ruiter, W J; Vlaar, S T; Bosman, F

    2000-08-01

    Static and dynamic occlusal interference frequently needs to be corrected by selective grinding of the occlusal surface of conventional cast and ceramic-fused-to-metal restorations. CAD/CAM techniques allow control of the dimensional contours of these restorations. However, parameters responsible for the occlusal form need to be determined. In most articulators, these parameters are set as default values. Which technique is best for minimizing the introduction of occlusal interference in restorations has not been determined. This study investigated differences in crown structure of a crown designed in static occlusion (STA) with designs adapted for dynamic occlusal interferences. Therefore, values from an optoelectronic registration system (String-Condylocomp, KAVO), an occlusal generated path (OGP) technique and default settings (DEF) were used in the CICERO CAD/CAM system. Morphology of CON, DEF, and OGP crowns was compared with that of the STA crown with respect to differences in a buccolingual section and frequency of occlusal distances in an interocclusal range of 1 mm, measured from the occlusal surface of the crown. All crown types fulfilled the esthetic and morphologic criteria for restorations in clinical dentistry. Difference in the morphology of the OGP crown, compared with that of the STA crown, was greater than that for the CON and DEF crowns. These differences were seen especially in the distobuccal part of the occlusal surface; however, the number of occlusal contacts was considered sufficient to stabilize occlusion. Functional occlusion, adapted to dynamic occlusion in a CICERO crown for the first mandibular molar, can be obtained using data acquired with the String-Condylocomp registration system. The OGP technique was preferred to other techniques because of the simplicity of the technique for eliminating potential problems with opposing teeth during motion. However, this is achieved at the cost of fewer points of contact during occlusion than

  20. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Survey the effect of aerobic exercise on aerobic capacity in patients with coronary artery disease (cad)

    International Nuclear Information System (INIS)

    Kalyani, M. N.; Ebadi, A.

    2007-01-01

    Increased aerobic exercise capacity appears to reduce both all-cause mortality and cardiovascular disease mortality. Physical exercise to improve maximal oxygen consumption (VO/sub 2max/) is thus strongly recommended, however evidence regarding the most efficient training intensity for patients with coronary artery disease (CAD) is still lacking. The purpose of this randomized study was to assess the effects of aerobic exercise for increasing VO/sub 2max/ in stable CAD-patients. Thirty stable CAD-patients were randomized to supervised walking 30 min three times a week for 10 weeks. Before and after training VO/sub 2max/ was predicted from Bruce treadmill test. Before training VO/sub 2max/ was 35.2+-4.32 ml/kg/min and after training the mean VO/sub 2max/ was 43.1+-3.4 ml/kg/min. This difference was significant (p<0.05). Aerobic exercise is effective for increasing VO/sub 2max/ in stable CAD-patients. As VO/sub 2max/ seems to reflect a continuum between health and cardiovascular disease and death, the present data may be useful in designing effective training programmes for improved health in the future. (author)

  2. Resin-composite blocks for dental CAD/CAM applications.

    Science.gov (United States)

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  3. Use of three-dimensional, CAD/CAM-assisted, virtual surgical simulation and planning in the pediatric craniofacial population.

    Science.gov (United States)

    Gray, Rachel; Gougoutas, Alexander; Nguyen, Vinh; Taylor, Jesse; Bastidas, Nicholas

    2017-06-01

    Virtual Surgical Planning (VSP) and computer-aided design/computer-aided manufacturing (CAD/CAM) have recently helped improve efficiency and accuracy in many different craniofacial surgeries. Research has mainly focused on the use in the adult population with the exception of the use for mandibular distractions and cranial vault remodeling in the pediatric population. This study aims to elucidate the role of VSP and CAD/CAM in complex pediatric craniofacial cases by exploring its use in the correction of midface hypoplasia, orbital dystopia, mandibular reconstruction, and posterior cranial vault expansion. A retrospective analysis of thirteen patients who underwent 3d, CAD/CAM- assisted preoperative surgical planning between 2012 and 2016 was performed. All CAD/CAM assisted surgical planning was done in conjunction with a third party vendor (either 3D Systems or Materialise). Cutting and positioning guides as well as models were produced based on the virtual plan. Surgeries included free fibula mandible reconstruction (n = 4), lefort I osteotomy and distraction (n = 2), lefort II osteotomy with monobloc distraction (n = 1), expansion of the posterior vault for correction of chiari malformation (n = 3), and secondary orbital and midface reconstruction for facial trauma (n = 3). The patient's age, diagnosis, previous surgeries, length of operating time, complications, and post-surgery satisfaction were determined. In all cases we found presurgical planning was helpful to improve accuracy and significantly decrease intra-operative time. In cases where distraction was used, the planned and actual vectors were found to be accurate with excellent clinical outcomes. There were no complications except for one patient who experienced a wound infection post-operatively which did not alter the ultimate reconstruction. All patients experienced high satisfaction with their outcomes and excellent subjective aesthetic results were achieved. Preoperative planning using

  4. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  5. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  6. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. A CAD (Classroom Assessment Design) of a Computer Programming Course

    Science.gov (United States)

    Hawi, Nazir S.

    2012-01-01

    This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified…

  8. Clinical observation on application of CAD/CAM technique in orbital reconstruction

    Directory of Open Access Journals (Sweden)

    Chang-Fu Peng

    2016-05-01

    Full Text Available AIM:To evaluate the clinical application of CAD/CAM(computer-aided design/computer-aided manufacturingtechnique in orbital reconstruction. METHODS:Thirty-three patients(33 eyeswere included who were admitted and accepted orbital reconstructionin operation in our hospital from June 2011 and October 2015. The three-dimensional(3Dmodel was made by CAD/CAM technology, according to the orbital three-dimensional CT examination for each patient preoperatively, and the repairing materials were shaped under 3D entity model in operation. The patients were followed up for 3-12mo, and the orbital shape, enophthalmos, diplopia and eye movement were observed. RESULTS:Among the 33 cases(33 eyes, except that 1 case required to remove the implants postoperative because of overcorrection, the patients were satisfied with the orbital shape. Enophthalmos were corrected. The effective rate was 97%. Among 19 cases(19 eyeswith diplopia and eye movement disorders, symptoms in 16 cases(16 eyeswere disappeared or improved, the efficiency rate was 84%. There were no operative complications. CONCLUSION:The CAD/CAM technique is effective and practical in the reconstruction of orbital deformity with shorter operation time, higher efficacy, better outcomes and lower risk, and it is worth to be popularized in clinical application. But the fabrication of 3D model costs certain money which may bring economic pressures to poor patients.

  9. Engineering drawing from first principles using AutoCAD

    CERN Document Server

    Maguire, Dennis E

    1998-01-01

    Engineering Drawing From First Principles is a guide to good draughting for students of engineering who need to learn how to produce technically accurate and detailed designs to British and International Standards. Written by Dennis Maguire, an experienced author and City and Guilds chief examiner, this text is designed for use on Further Education and University courses where a basic understanding of draughtsmanship and CAD is necessary. Although not written as an AutoCAD tutor, the book will be a useful introduction to good CAD practice.Part of the Revision and Self-Assessmen

  10. VLSI Design with Alliance Free CAD Tools: an Implementation Example

    Directory of Open Access Journals (Sweden)

    Chávez-Bracamontes Ramón

    2015-07-01

    Full Text Available This paper presents the methodology used for a digital integrated circuit design that implements the communication protocol known as Serial Peripheral Interface, using the Alliance CAD System. The aim of this paper is to show how the work of VLSI design can be done by graduate and undergraduate students with minimal resources and experience. The physical design was sent to be fabricated using the CMOS AMI C5 process that features 0.5 micrometer in transistor size, sponsored by the MOSIS Educational Program. Tests were made on a platform that transfers data from inertial sensor measurements to the designed SPI chip, which in turn sends the data back on a parallel bus to a common microcontroller. The results show the efficiency of the employed methodology in VLSI design, as well as the feasibility of ICs manufacturing from school projects that have insufficient or no source of funding

  11. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  13. 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle detection

    Science.gov (United States)

    Vignetti, M. M.; Calmon, F.; Pittet, P.; Pares, G.; Cellier, R.; Quiquerez, L.; Chaves de Albuquerque, T.; Bechetoille, E.; Testa, E.; Lopez, J.-P.; Dauvergne, D.; Savoy-Navarro, A.

    2018-02-01

    Single-Photon Avalanche Diodes (SPADs) are p-n junctions operated in Geiger Mode by applying a reverse bias above the breakdown voltage. SPADs have the advantage of featuring single photon sensitivity with timing resolution in the picoseconds range. Nevertheless, their relatively high Dark Count Rate (DCR) is a major issue for charged particle detection, especially when it is much higher than the incoming particle rate. To tackle this issue, we have developed a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD). This novel device implements two vertically aligned SPADs featuring on-chip electronics for the detection of coincident avalanche events occurring on both SPADs. Such a coincidence detection mode allows an efficient discrimination of events related to an incoming charged particle (producing a quasi-simultaneous activation of both SPADs) from dark counts occurring independently on each SPAD. A 3D-SiCAD detector prototype has been fabricated in CMOS technology adopting a 3D flip-chip integration technique, and the main results of its characterization are reported in this work. The particle detection efficiency and noise rejection capability for this novel device have been evaluated by means of a β- strontium-90 radioactive source. Moreover the impact of the main operating parameters (i.e. the hold-off time, the coincidence window duration, the SPAD excess bias voltage) over the particle detection efficiency has been studied. Measurements have been performed with different β- particles rates and show that a 3D-SiCAD device outperforms single SPAD detectors: the former is indeed capable to detect particle rates much lower than the individual DCR observed in a single SPAD-based detectors (i.e. 2 to 3 orders of magnitudes lower).

  14. CAD – CAM PROCEDURE USING FOR RAPID PROTOTYPING WITH APPLICATION IN BIOMECHANICS

    Directory of Open Access Journals (Sweden)

    BRAUN Barbu

    2015-06-01

    Full Text Available The paper presents a new and efficient method for modeling some components with application in Biomechanics. It is shown the way in which this method could be successfully applied for orthopedic shoes, namely for foot insoles to correct any plantar deformities. The main advantages of the proposed method refer to low costs, successfully applying for different products for Biomechanics. The prototyped models via CAD/CAM method allowed a rapid and efficient improvement of their design. Another advantage refer to the fact that these can be properly and efficiently tested before prototyping by the point of view of mechanical stress, due to prior simulations, eliminating all costs meaning wastes or adjustments.

  15. 3D CAD ON Qinshan CANDU project

    International Nuclear Information System (INIS)

    Goland, D.

    2000-01-01

    This paper briefly describe AECL's work in applying computer-aided engineering tools to the Qinshan CANDU project. The main thrust of this paper is to introduce the major CAD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CAD tools and their applications are also briefly introduced. (author)

  16. A comparative evaluation of implant supported zirconia framework gap of two CAD/CAM systems

    Directory of Open Access Journals (Sweden)

    Narges Ameri

    2016-11-01

    computer-aided manufacturing (CAM systems (AmannGirrbach and Zirkonzahn. Materials and Methods: The master model of 3-unit FDP was made of two implant abutments (AmannGirrbach and Zirkonzahn from canine to second premolar. Twelve frameworks were manufactured using each fabricating system from semi-sintered zirconia blanks, which had to be sintered for final density after milling. After manufacturing, the absolute marginal discrepancy in each abutment were determined by means of Video Measurement System (VMS. The data were analyzed, using independent and paired t test (P=0.05. Results: For the premolar abutment, the absolute marginal discrepancy of frameworks fabricated by AmannGirrbach system was significantly greater than those of the other system (P=0.005. There was no significant difference between the marginal discrepancy of canine and premolar abutments (P>0.05. Conclusion: Within the limitations of this study, it could be concluded that the marginal fit of zirconia FDPs was significantly dependent on the CAD/CAM system used, but the abutment size was not an effective factor.

  17. Converting Geometry from Creo Parametric to BRL-CAD

    Science.gov (United States)

    2017-06-28

    SUPPLEMENTARY NOTES 14. ABSTRACT There exists in vulnerability /lethality analysis an ongoing need to convert target geometries from commercial systems...Contents List of Figures iv 1. Using Commercially Produced Models in Vulnerability /Lethality Analysis 1 2. Installing the Creo to BRL-CAD Converter...distribution is unlimited. 1 1. Using Commercially Produced Models in Vulnerability / Lethality Analysis Vulnerability /lethality (V/L) analysis

  18. KiCad challenges the big ones

    CERN Document Server

    Antonella Del Rosso

    2015-01-01

    Printed Circuit Boards (PCB) are the heart of any electronic device, including your toaster and your smartphone. Designing PCBs is the job of electronic engineers who, so far, have often had no option but to use proprietary tools to design complex circuits. Thanks to the efforts that CERN experts have put in to improve the free KiCad software, that situation is about to change.   KiCad's development started in 1992 as a way to design PCBs, the units that control how an electronic device works. Since 2013, experts in the Beams department have made important contributions to KiCad as part of the Open Hardware Initiative (OHI), which provides a framework to facilitate knowledge exchange across the electronic design community. “Our vision is to allow the hardware developers to share as easily as their software colleagues,” says Javier Serrano, head of the BE-CO-HT section and OHI initiator. “Software sources are easily shared online because they are text ...

  19. User productivity as a function of AutoCAD interface design.

    Science.gov (United States)

    Mitta, D A; Flores, P L

    1995-12-01

    Increased operator productivity is a desired outcome of user-CAD interaction scenarios. Two objectives of this research were to (1) define a measure of operator productivity and (2) empirically investigate the potential effects of CAD interface design on operator productivity, where productivity is defined as the percentage of a drawing session correctly completed per unit time. Here, AutoCAD provides the CAD environment of interest. Productivity with respect to two AutoCAD interface designs (menu, template) and three task types (draw, dimension, display) was investigated. Analysis of user productivity data revealed significantly higher productivity under the menu interface condition than under the template interface condition. A significant effect of task type was also discovered, where user productivity under display tasks was higher than productivity under the draw and dimension tasks. Implications of these results are presented.

  20. The National Shipbuilding Research Program. 1997 Ship Production Symposium. Implementation of Integrated CAD/CAM Systems in Small and Medium Sized Shipyards: A Case Study

    National Research Council Canada - National Science Library

    Mercier, Larry; Byington, Tracy; Senkwic, Walt; Barry, Christopher

    1997-01-01

    .... Implementing CAD/CAM is primarily a management, rather than technical, challenge. Performance-Based Management Techniques were used to develop the new system as an integrated whole, controlled and documented under ISO 9001...

  1. Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

    Science.gov (United States)

    Ahrberg, Danush; Lauer, Hans Christoph; Ahrberg, Martin; Weigl, Paul

    2016-03-01

    The aim of this clinical trial was to evaluate the marginal and internal fit of CAD/CAM fabricated zirconia crowns and three-unit fixed dental prostheses (FDPs) resulting from direct versus indirect digitalization. The efficiency of both methods was analyzed. In 25 patients, 17 single crowns and eight three-unit FDPs were fabricated with all-ceramic zirconia using CAD/CAM technology. Each patient underwent two different impression methods; a computer-aided impression with Lava C.O.S. (CAI) and a conventional polyether impression with Impregum pent soft (CI). The working time for each group was recorded. Before insertion, the marginal and internal fit was recorded using silicone replicas of the frameworks. Each sample was cut into four sections and evaluated at four sites (marginal gap, mid-axial wall, axio-occlusal transition, centro-occlusal site) under ×64 magnification. The Mann-Whitney U test was used to detect significant differences between the two groups in terms of marginal and internal fit (α = 0.05). The mean for the marginal gap was 61.08 μm (±24.77 μm) for CAI compared with 70.40 μm (±28.87 μm) for CI, which was a statistically significant difference. The other mean values for CAI and CI, respectively, were as follows in micrometers (± standard deviation): 88.27 (±41.49) and 92.13 (±49.87) at the mid-axial wall; 144.78 (±46.23) and 155.60 (±55.77) at the axio-occlusal transition; and 155.57 (49.85) and 171.51 (±60.98) at the centro-occlusal site. The CAI group showed significantly lower values of internal fit at the centro-occlusal site. A quadrant scan with a computer-aided impression was 5 min 6 s more time efficient when compared with a conventional impression, and a full-arch scan was 1 min 34 s more efficient. Although both direct and indirect digitalization facilitate the fabrication of single crowns and three-unit FDPs with clinically acceptable marginal fit, a significantly better marginal fit was noted with direct

  2. Teach CAD and Measuring Skills through Reverse Engineering

    Science.gov (United States)

    Board, Keith

    2012-01-01

    This article describes a reverse engineering activity that gives students hands-on, minds-on experience with measuring tools, machine parts, and CAD. The author developed this activity to give students an abundance of practical experience with measuring tools. Equally important, it provides a good interface between the virtual world of CAD 3D…

  3. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    Science.gov (United States)

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and pCAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental

  4. Computer-aided detection (CAD) of lung nodules and small tumours on chest radiographs

    International Nuclear Information System (INIS)

    De Boo, D.W.; Prokop, M.; Uffmann, M.; Ginneken, B. van; Schaefer-Prokop, C.M.

    2009-01-01

    Detection of focal pulmonary lesions is limited by quantum and anatomic noise and highly influenced by variable perception capacity of the reader. Multiple studies have proven that lesions - missed at time of primary interpretation - were visible on the chest radiographs in retrospect. Computer-aided diagnosis (CAD) schemes do not alter the anatomic noise but aim at decreasing the intrinsic limitations and variations of human perception by alerting the reader to suspicious areas in a chest radiograph when used as a 'second reader'. Multiple studies have shown that the detection performance can be improved using CAD especially for less experienced readers at a variable amount of decreased specificity. There seem to be a substantial learning process for both, experienced and inexperienced readers, to be able to optimally differentiate between false positive and true positive lesions and to build up sufficient trust in the capabilities of these systems to be able to use them at their full advantage. Studies so far focussed on stand-alone performance of the CAD schemes to reveal the magnitude of potential impact or on retrospective evaluation of CAD as a second reader for selected study groups. Further research is needed to assess the performance of these systems in clinical routine and to determine the trade-off between performance increase in terms of increased sensitivity and decreased inter-reader variability and loss of specificity and secondary indicated follow-up examinations for further diagnostic workup.

  5. Role of Computer Aided Diagnosis (CAD in the detection of pulmonary nodules on 64 row multi detector computed tomography

    Directory of Open Access Journals (Sweden)

    K Prakashini

    2016-01-01

    Full Text Available Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2% and 202 (91.4% by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4% and nodules in hilar (100% and central (96.5% location when compared to RAD′s performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD′s performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  6. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    Science.gov (United States)

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  7. Improving digital breast tomosynthesis reading time: A pilot multi-reader, multi-case study using concurrent Computer-Aided Detection (CAD).

    Science.gov (United States)

    Balleyguier, Corinne; Arfi-Rouche, Julia; Levy, Laurent; Toubiana, Patrick R; Cohen-Scali, Franck; Toledano, Alicia Y; Boyer, Bruno

    2017-12-01

    Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0

  8. Effect of Finishing and Polishing on Roughness and Gloss of Lithium Disilicate and Lithium Silicate Zirconia Reinforced Glass Ceramic for CAD/CAM Systems.

    Science.gov (United States)

    Vichi, A; Fonzar, R Fabian; Goracci, C; Carrabba, M; Ferrari, M

    To assess the efficacy of dedicated finishing/polishing systems on roughness and gloss of VITA Suprinity and IPS e.max CAD. A total of 24 blocks of Suprinity and 24 of e.max were cut into a wedge shape using an InLab MC-XL milling unit. After crystallization, the 24 Suprinity wedges were divided into four subgroups: group A.1: Suprinity Polishing Set Clinical used for 30 seconds and group A.2: for 60 seconds; group A.3: VITA Akzent Plus Paste; and group A.4: spray. The 24 e.max wedges (group B) were divided into four subgroups according to the finishing procedure: group B.1: Optrafine Ceramic Polishing System for 30 seconds and group B.2: for 60 seconds; group B.3: IPS e.max CAD Crystall/Glaze paste; and group B.4: spray. After finishing/polishing, gloss was assessed with a glossmeter and roughness evaluated with a profilometer. Results were analyzed by applying a two-way analysis of variance for gloss and another for roughness (α=0.05). One specimen per each subgroup was observed with a scanning electron microscope. For roughness, materials and surface were significant factors ( pgloss, both material and surface treatment were significant factors ( pgloss than e.max. Also the Material-Surface Treatment interaction was statistically significant ( pgloss. VITA Suprinity displayed higher polishability than IPS e.max CAD.

  9. Comparison of plantar pressure distribution in CAD-CAM and prefabricated foot orthoses in patients with flexible flatfeet.

    Science.gov (United States)

    Khodaei, Banafsheh; Saeedi, Hassan; Jalali, Maryam; Farzadi, Maede; Norouzi, Ehsan

    2017-12-01

    The effect of foot orthoses on plantar pressure distribution has been proven by researchers but there are some controversies about advantages of custom-made foot orthoses to less expensive prefabricated foot orthoses. Nineteen flatfeet adults between 18 and 45 participated in this study. CAD-CAM foot orthoses were made for these patients according to their foot scan. Prefabricated foot orthoses were prepared according to their foot size. Plantar pressure, force and contact area were measured using pedar ® -x in-shoe system wearing shoe alone, wearing CAD-CAM foot orthoses and wearing prefabricated foot orthoses. Repeated measures ANOVA model with post-hoc, Bonferroni comparison were used to test differences. CAD-CAM and prefabricated foot orthoses both decreased pressure and force under 2nd, 3-5 metatarsal and heel regions comparing to shoe alone condition. CAD-CAM foot orthosis increased pressure under lateral toe region in comparison to shoe alone and prefabricated foot orthosis. Both foot orthoses increased pressure and contact area in medial midfoot region comparing to shoe alone condition. Increased forces were seen at hallux and lateral toes by prefabricated foot orthoses in comparison with CAD-CAM foot orthoses and control condition, respectively. According to the results, both foot orthoses could decrease the pressure under heel and metatarsal area. It seems that the special design of CAD-CAM foot orthoses could not make great differences in plantar pressure distribution in this sample. Further research is required to determine whether these results are associated with different scan systems or design software. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Transcriptome-wide identification and characterization of CAD isoforms specific for podophyllotoxin biosynthesis from Podophyllum hexandrum.

    Science.gov (United States)

    Bhattacharyya, Dipto; Hazra, Saptarshi; Banerjee, Anindyajit; Datta, Riddhi; Kumar, Deepak; Chakrabarti, Saikat; Chattopadhyay, Sharmila

    2016-09-01

    Podophyllotoxin (ptox) is a therapeutically important lignan derived from Podophyllum hexandrum and is used as a precursor for the synthesis of anticancer drugs etoposide, teniposide and etopophose. In spite of its enormous economic significance, genomic information on this endangered medicinal herb is scarce. We have performed de novo transcriptome analysis of methyl jasmonate (MeJA)-treated P. hexandrum cell cultures exhibiting enhanced ptox accumulation. The results revealed the maximum up-regulation of several isoforms of cinnamyl alcohol dehydrogenase (CAD). CAD catalyzes the synthesis of coniferyl alcohol and sinapyl alcohol from coniferaldehyde (CAld) and sinapaldehyde respectively. Coniferyl alcohol can produce both lignin and lignan while sinapyl alcohol produces only lignin. To isolate the CAD isoforms favoring ptox, we deduced full length cDNA sequences of four CAD isoforms: PhCAD1, PhCAD2, PhCAD3 and PhCAD4 from the contigs of the transcriptome data. In vitro enzyme assays indicated a higher affinity for CAld over sinapaldehyde for each isoform. In silico molecular docking analyses also suggested that PhCAD3 has a higher binding preference with CAld over sinapaldehyde, followed by PhCAD4, PhCAD2, and PhCAD1, respectively. The transgenic cell cultures overexpressing these isoforms independently revealed that PhCAD3 favored the maximum accumulation of ptox as compared to lignin followed by PhCAD4 and PhCAD2, whereas, PhCAD1 favored both equally. Together, our study reveals transcriptome-wide identification and characterization of ptox specific CAD isoforms from P. hexandrum. It provides a useful resource for future research not only on the ptox biosynthetic pathway but on overall P. hexandrum, an endangered medicinal herb with immense therapeutic importance.

  11. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites.

    Science.gov (United States)

    Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik

    2015-03-01

    To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (pCAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (pCAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (pcurry>cress>distilled water) exerted the highest influence on DR (pCAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (pCAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The dynamic interaction of order flows and the CAD/USD exchange rate

    OpenAIRE

    Nikola Gradojevic; Christopher J. Neely

    2008-01-01

    We explore the relationship between disaggregated order flow, the Canada/U.S. dollar (CAD/USD) market and U.S. macroeconomic announcements. Three types of CAD order flow and the CAD/USD are cointegrated. Financial order flow appears to contemporaneously drive the CAD/USD while commercial order flow seems to contemporaneously respond to exchange rate movements. Past order flow and lagged exchange rates strongly explain most types of order flow. Despite this predictability and the contemporaneo...

  13. Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods.

    Science.gov (United States)

    de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As

    The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

  14. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    Science.gov (United States)

    2011-01-01

    provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473

  15. Association of rs662799 in APOA5 with CAD in Chinese Han population.

    Science.gov (United States)

    Chen, Hua; Ding, Shifang; Zhou, Mi; Wu, Xiayin; Liu, Xi; Wu, Yun; Liu, Dechao

    2018-01-08

    CAD (Coronary Artery Disease) is a complex disease that influenced by various environmental and genetic factors. Previous studies have found many single nucleotide polymorphisms (SNPs) associated with the risk of CAD occurrence. However, the results are inconsistent. In this study, we aim to investigate genetic etiology in Chinese Han population by analysis of 7 SNPs in lipid metabolism pathway that previously has been reported to be associated with CAD. A total of 631 samples were used in this study, including 435 CAD cases and 196 normal healthy controls. SNP genotyping were conducted via multiplex PCR amplifying followed by NGS (next-generation sequencing). Rs662799 in APOA5 (Apolipoprotein A5) gene was associated with CAD in Chinese Han population (Odds-ratio = 1.374, P-value = 0.03). No significant association was observed between the rest of SNPs and CAD. Stratified association analysis revealed rs5882 was associated with CAD in non-hypertension group (Odds-ratio = 1.593, P-value = 0.023). Rs1800588 was associated with CAD in smoking group (Odds-ratio = 1.603, P-value = 0.035). The minor allele of rs662799 was the risk factor of CAD occurrences in Chinese Han population.

  16. Listeria monocytogenes CadC Regulates Cadmium Efflux and Fine-tunes Lipoprotein Localization to Escape the Host Immune Response and Promote Infection.

    Science.gov (United States)

    Pombinho, Rita; Camejo, Ana; Vieira, Ana; Reis, Olga; Carvalho, Filipe; Almeida, Maria Teresa; Pinheiro, Jorge Campos; Sousa, Sandra; Cabanes, Didier

    2017-05-01

    Listeria monocytogenes is a major intracellular human foodborne bacterial pathogen. We previously revealed L. monocytogenes cadC as highly expressed during mouse infection. Here we show that L. monocytogenes CadC is a sequence-specific, DNA-binding and cadmium-dependent regulator of CadA, an efflux pump conferring cadmium resistance. CadC but not CadA is required for L. monocytogenes infection in vivo. Interestingly, CadC also directly represses lspB, a gene encoding a lipoprotein signal peptidase whose expression appears detrimental for infection. lspB overexpression promotes the release of the LpeA lipoprotein to the extracellular medium, inducing tumor necrosis factor α and interleukin 6 expression, thus impairing L. monocytogenes survival in macrophages. We propose that L. monocytogenes uses CadC to repress lspB expression during infection to avoid LpeA exposure to the host immune system, diminishing inflammatory cytokine expression and promoting intramacrophagic survival and virulence. CadC appears as the first metal efflux pump regulator repurposed during infection to fine-tune lipoprotein processing and host responses. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  17. Model-Based Engineering and Manufacturing CAD/CAM Benchmark

    International Nuclear Information System (INIS)

    Domm, T.D.; Underwood, R.S.

    1999-01-01

    The Benehmark Project was created from a desire to identify best practices and improve the overall efficiency and performance of the Y-12 Plant's systems and personnel supporting the manufacturing mission. The mission of the benchmark team was to search out industry leaders in manufacturing and evaluate their engineering practices and processes to determine direction and focus fm Y-12 modmizadon efforts. The companies visited included several large established companies and anew, small, high-tech machining firm. As a result of this effort changes are recommended that will enable Y-12 to become a more responsive cost-effective manufacturing facility capable of suppording the needs of the Nuclear Weapons Complex (NW at sign) and Work Fw Others into the 21' century. The benchmark team identified key areas of interest, both focused and gencml. The focus arm included Human Resources, Information Management, Manufacturing Software Tools, and Standarda/ Policies and Practices. Areas of general interest included Inhstructure, Computer Platforms and Networking, and Organizational Structure. The method for obtaining the desired information in these areas centered on the creation of a benchmark questionnaire. The questionnaire was used throughout each of the visits as the basis for information gathering. The results of this benchmark showed that all companies are moving in the direction of model-based engineering and manufacturing. There was evidence that many companies are trying to grasp how to manage current and legacy data. In terms of engineering design software tools, the companies contacted were using both 3-D solid modeling and surfaced Wire-frame models. The manufacturing computer tools were varie4 with most companies using more than one software product to generate machining data and none currently performing model-based manufacturing (MBM) ftom a common medel. The majority of companies were closer to identifying or using a single computer-aided design (CAD) system

  18. An Instructional Method for the AutoCAD Modeling Environment.

    Science.gov (United States)

    Mohler, James L.

    1997-01-01

    Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)

  19. TEACHING CAD PROGRAMMING TO ARCHITECTURE STUDENTS

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Caffarena CELANI

    2008-11-01

    Full Text Available The objective of this paper is to discuss the relevance of including the discipline of computer programming in the architectural curriculum. To do so I start by explaining how computer programming has been applied in other educational contexts with pedagogical success, describing Seymour Papert's principles. After that, I summarize the historical development of CAD and provide three historical examples of educational applications of computer programming in architecture, followed by a contemporary case that I find of particular relevance. Next, I propose a methodology for teaching programming for architects that aims at improving the quality of designs by making their concepts more explicit. This methodology is based on my own experience teaching computer programming for architecture students at undergraduate and graduate levels at the State University of Campinas, Brazil. The paper ends with a discussion about the role of programming nowadays, when most CAD software are user-friendly and do not require any knowledge of programming for improving performance. I conclude that the introduction of programming in the CAD curriculum within a proper conceptual framework may transform the concept of architectural education. Key-words: Computer programming; computer-aided design; architectural education.

  20. 28th International Conference on CAD/CAM, Robotics and Factories of the Future

    CERN Document Server

    Syan, Chanan

    2016-01-01

    This volume is based on the proceedings of the 28th International Conference on CAD/CAM, Robotics and Factories of the Future. This book specially focuses on the positive changes made in the field of robotics, CAD/CAM and future outlook for emerging manufacturing units. Some of the important topics discussed in the conference are product development and sustainability, modeling and simulation, automation, robotics and handling systems, supply chain management and logistics, advanced manufacturing processes, human aspects in engineering activities, emerging scenarios in engineering education and training. The contents of this set of proceedings will prove useful to both researchers and practitioners.

  1. Reproducibility of prompts in computer-aided detection (CAD) of breast cancer

    International Nuclear Information System (INIS)

    Taylor, C.G.; Champness, J.; Reddy, M.; Taylor, P.; Potts, H.W.W.; Given-Wilson, R.

    2003-01-01

    AIM: We evaluated the reproducibility of prompts using the R2 ImageChecker M2000 computer-aided detection (CAD) system. MATERIALS AND METHODS: Forty selected two-view mammograms of women with breast cancer were digitized and analysed using the ImageChecker on 10 separate occasions. The mammograms were chosen to provide both straightforward and subtle signs of malignancy. Data analysed included mammographic abnormality, pathology, and whether the cancer was prompted or given an emphasized prompt. RESULTS: Correct prompts were generated in 86 out of 100 occasions for screen-detected cancers. Reproducibility was less in the other categories of more subtle cancers: 21% for cancers previously missed by CAD, a group that contained more grade 1 and small (<10 mm) tumours. Prompts for calcifications were more reproducible than those for masses (76% versus 53%) and these cancers were more likely to have an emphasized prompt. CONCLUSIONS: Probably the most important cause of variability of prompts is shifts in film position between sequential digitizations. Consequently subtle lesions that are only just above the threshold for display may not be prompted on repeat scanning. However, users of CAD should be aware that even emphasized prompts are not consistently reproducible

  2. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    International Nuclear Information System (INIS)

    Lee, Eun Sun; Kim, Se Hyung; Im, Jong Pil; Kim, Sang Gyun; Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn

    2015-01-01

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  3. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Im, Jong Pil; Kim, Sang Gyun [Department of Internal Medicine, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2015-04-15

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  4. AutoCAD Civil 3D 2014 essentials

    CERN Document Server

    Chappell, Eric

    2013-01-01

    Quickly learn essential Civil 3D tools and techniques Get a thorough introduction to AutoCAD Civil 3D, the industry-leading engineering software used to design roads, highways, subdivisions, drainage and sewer systems, and more. This Autodesk Official Press book is a unique learning resource that features concise, straightforward explanations and real-world, hands-on exercises and tutorials. With compelling full-color screenshots and approachable exercises that demonstrate core features and functions, the book helps you gain understanding and confidence as you master this premiere

  5. AutoCAD-To-GIFTS Translator Program

    Science.gov (United States)

    Jones, Andrew

    1989-01-01

    AutoCAD-to-GIFTS translator program, ACTOG, developed to facilitate quick generation of small finite-element models using CASA/GIFTS finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Geometric entities recognized by ACTOG include points, lines, arcs, solids, three-dimensional lines, and three-dimensional faces. From this information, ACTOG creates GIFTS SRC file, which then reads into GIFTS preprocessor BULKM or modified and reads into EDITM to create finite-element model. SRC file used as is or edited for any number of uses. Written in Microsoft Quick-Basic (Version 2.0).

  6. Deactivation of the E. coli pH stress sensor CadC by cadaverine.

    Science.gov (United States)

    Haneburger, Ina; Fritz, Georg; Jurkschat, Nicole; Tetsch, Larissa; Eichinger, Andreas; Skerra, Arne; Gerland, Ulrich; Jung, Kirsten

    2012-11-23

    At acidic pH and in the presence of lysine, the pH sensor CadC activates transcription of the cadBA operon encoding the lysine/cadaverine antiporter CadB and the lysine decarboxylase CadA. In effect, these proteins contribute to acid stress adaptation in Escherichia coli. cadBA expression is feedback inhibited by cadaverine, and a cadaverine binding site is predicted within the central cavity of the periplasmic domain of CadC on the basis of its crystallographic analysis. Our present study demonstrates that this site only partially accounts for the cadaverine response in vivo. Instead, evidence for a second, pivotal binding site was collected, which overlaps with the pH-responsive patch of amino acids located at the dimer interface of the periplasmic domain. The temporal response of the E. coli Cad module upon acid shock was measured and modeled for two CadC variants with mutated cadaverine binding sites. These studies supported a cascade-like binding and deactivation model for the CadC dimer: binding of cadaverine within the pair of central cavities triggers a conformational transition that exposes two further binding sites at the dimer interface, and the occupation of those stabilizes the inactive conformation. Altogether, these data represent a striking example for the deactivation of a pH sensor. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Implementasi Penggunaan Aplikasi AutoCAD dalam Meningkatkan Kompetensi Dasar Menggambar teknik bagi Masyarakat

    Directory of Open Access Journals (Sweden)

    Risma Dwi Atmajayani

    2018-05-01

    Full Text Available Dengan berkembangnya teknologi, maka gambarpun ikut mengalami kemajuan dalam penggunaannya. Dengan kecanggihan dan kemajuan teknologi dapat melahirkan suatu cara menggambar dengan media komputer. Teknologi dapat membantu mempercepat menyelesaikan suatu pekerjaan, tidak terkecuali aplikasi CAD (Computer Aided Design. Program yang sering digunakan untuk pengajaran CAD adalah AutoCAD yang merupakan sebuah aplikasi (software yang digunakan untuk menggambar, mendesain gambar, menguji material dimana program tersebut mempunyai kemudahan dan keunggulan untuk membuat gambar secara tepat dan akurat. Berdasarkan temuan dilapangan yang didasari tinjauan langsung, didapatkan informasi bahwa materi AutoCAD yang diperoleh dari jenjang sebelumnya masih banyak yang jauh dari kondisi ideal. Materi AutoCAD yang didapatkan masih banyak tentang teori sedikit praktek, perangkat hardware yang terbatas sampai pada ketersediaan sumber daya manusia yang kurang adalah permasalahan umum yang terjadi. Adapun tujuan yang ingin dicapai adalah (1 Meningkatkan mutu peserta pelatihan melalui workshop pemanfaatan aplikasi AutoCAD (2 Meningkatkan ketrampilan peserta pelatihan dengan membuat suatu proyek desain gambar bangun berbasis aplikasi AutoCAD. Manfaat kegiatan pelatihan adalah: (1 Peserta pelatihan dapat meningkatkan pemahaman tentang program AutoCAD; (2 Peserta pelatihan dapat menyalurkan pengetahuan dan ketrampilan yang didapatkan nantinya kepada yang membutuhkan dan terutama akan sangat membantu para calon civil engineer dalam menyelesaikan pekerjaan yang berkaitan dengan desain rancang bangun; (3 Peserta pelatihan dapat mendesain gambar menggunakan program AutoCAD.

  8. Complete PCB design using OrCAD capture and layout

    CERN Document Server

    Mitzner, Kraig

    2011-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The book is written for both students and practicing engineers who need a quick tutorial on how to use the software and who need in-depth knowledge of the capabilities and limitations of the software package. There are two goals the book aims to reach:The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Layout. Capture is used to build the schematic diagram of the circuit, and Layout is used to design the circuit board so that

  9. CAD/CAM: improved design quality, increased productivity

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D. E.; England, J.

    1980-01-01

    Maintaining productivity levels while assuring the quality of engineering products grows increasingly more difficult and costly for industries such as the energy industry which are heavily committed to product design. The man/machine interface made possible through the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology can be applied to the design process as a tool for increased control to assure the quality of the final engineering product. The quality-control aspects of CAD/CAM technology are addressed in this presentation.

  10. Research on remote sensing image pixel attribute data acquisition method in AutoCAD

    Science.gov (United States)

    Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui

    2013-07-01

    The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.

  11. Utilizing optical coherence tomography for CAD/CAM of indirect dental restorations

    Science.gov (United States)

    Chityala, Ravishankar; Vidal, Carola; Jones, Robert

    Optical Coherence Tomography (OCT) has seen broad application in dentistry including early carious lesion detection and imaging defects in resin composite restorations. This study investigates expanding the clinical usefulness by investigating methods to use OCT for obtaining three-dimensional (3D) digital impressions, which can be integrated to CAD/CAM manufacturing of indirect restorations. 3D surface topography `before' and `after' a cavity preparation was acquired by an intraoral cross polarization swept source OCT (CP-OCT) system with a Micro-Electro-Mechanical System (MEMS) scanning mirror. Image registration and segmentation methods were used to digitally construct a replacement restoration that modeled the original surface morphology of a hydroxyapatite sample. After high resolution additive manufacturing (e.g. polymer 3D printing) of the replacement restoration, micro-CT imaging was performed to examine the marginal adaptation. This study establishes the protocol for further investigation of integrating OCT with CAD/CAM of indirect dental restorations.

  12. Trends in CAD education in interior design programs

    OpenAIRE

    Ko, Hye Mi

    1990-01-01

    This research investigated Computer Aided Design (CAD) education in the interior design. program focusing on educators' opinions about creativity aspects including computer application, teaching materials and teaching methods as well as other trends in CAD education. A questionnaire was sent to one hundred eighty-two members of the Interior Design Educators Council (IDEC). A frequency distribution was used on 69 usable returned surveys to describe the sample characteristi...

  13. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    Science.gov (United States)

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  14. Neutronics analysis of the International Thermonuclear Experimental Reactor (ITER) MCNP ''Benchmark CAD Model'' with the ATTILA discrete ordinance code

    International Nuclear Information System (INIS)

    Youssef, M.Z.; Feder, R.; Davis, I.

    2007-01-01

    The ITER IT has adopted the newly developed FEM, 3-D, and CAD-based Discrete Ordinates code, ATTILA for the neutronics studies contingent on its success in predicting key neutronics parameters and nuclear field according to the stringent QA requirements set forth by the Management and Quality Program (MQP). ATTILA has the advantage of providing a full flux and response functions mapping everywhere in one run where components subjected to excessive radiation level and strong streaming paths can be identified. The ITER neutronics community had agreed to use a standard CAD model of ITER (40 degree sector, denoted ''Benchmark CAD Model'') to compare results for several responses selected for calculation benchmarking purposes to test the efficiency and accuracy of the CAD-MCNP approach developed by each party. Since ATTILA seems to lend itself as a powerful design tool with minimal turnaround time, it was decided to benchmark this model with ATTILA as well and compare the results to those obtained with the CAD MCNP calculations. In this paper we report such comparison for five responses, namely: (1) Neutron wall load on the surface of the 18 shield blanket module (SBM), (2) Neutron flux and nuclear heating rate in the divertor cassette, (3) nuclear heating rate in the winding pack of the inner leg of the TF coil, (4) Radial flux profile across dummy port plug and shield plug placed in the equatorial port, and (5) Flux at seven point locations situated behind the equatorial port plug. (orig.)

  15. Fracture, roughness and phase transformation in CAD/CAM milling and subsequent surface treatments of lithium metasilicate/disilicate glass-ceramics.

    Science.gov (United States)

    Alao, Abdur-Rasheed; Stoll, Richard; Song, Xiao-Fei; Abbott, John R; Zhang, Yu; Abduo, Jaafar; Yin, Ling

    2017-10-01

    This paper studied surface fracture, roughness and morphology, phase transformations, and material removal mechanisms of lithium metasilicate/disilicate glass ceramics (LMGC/LDGC) in CAD/CAM-milling and subsequent surface treatments. LMGC (IPS e.max CAD) blocks were milled using a chairside dental CAD/CAM milling unit and then treated in sintering, polishing and glazing processes. X-ray diffraction was performed on all processed surfaces. Scanning electron microscopy (SEM) was applied to analyse surface fracture and morphology. Surface roughness was quantitatively characterized by the arithmetic average surface roughness R a and the maximum roughness R z using desktop SEM-assisted morphology analytical software. The CAD/CAM milling induced extensive brittle cracks and crystal pulverization on LMGC surfaces, which indicate that the dominant removal mechanism was the fracture mode. Polishing and sintering of the milled LMGC lowered the surface roughness (ANOVA, p 0.05). In comparison of all applied fabrication process routes, it is found that CAD/CAM milling followed by polishing and sintering produced the smoothest surface with R a = 0.12 ± 0.08µm and R z = 0.89 ± 0.26µm. Thus , it is proposed as the optimized process route for LMGC/LDGC in dental restorations. This route enables to manufacture LMGC/LDGC restorations with cost effectiveness, time efficiency, and improved surface quality for better occlusal functions and reduced bacterial plaque accumulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    Science.gov (United States)

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p CAD/CAM PMMA-based M (p CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  17. Assessment of the Use of AutoCAD in Mechanical Engineering Technical Drawing Education

    OpenAIRE

    Akyürek, Turgut

    2018-01-01

    AutoCAD is one of the widely used software tools in engineering education. In this study, ageneral assessment of AutoCAD for the usage in the mechanical engineering technical drawing educationis made. AutoCAD is assessed in terms of the fulfilment of the requirements defined for the main twotechnical drawing courses. AutoCAD is assessed in terms of its capability in meeting the requirements ofthe technical drawing courses.

  18. Can breast MRI computer-aided detection (CAD) improve radiologist accuracy for lesions detected at MRI screening and recommended for biopsy in a high-risk population?

    International Nuclear Information System (INIS)

    Arazi-Kleinman, T.; Causer, P.A.; Jong, R.A.; Hill, K.; Warner, E.

    2009-01-01

    Aim: To evaluate the sensitivity and specificity of magnetic resonance imaging (MRI) computer-aided detection (CAD) for breast MRI screen-detected lesions recommended for biopsy in a high-risk population. Material and methods: Fifty-six consecutive Breast Imaging Reporting and Data System (BI-RADS) 3-5 lesions with histopathological correlation [nine invasive cancers, 13 ductal carcinoma in situ (DCIS) and 34 benign] were retrospectively evaluated using a breast MRI CAD prototype (CAD-Gaea). CAD evaluation was performed separately and in consensus by two radiologists specializing in breast imaging, blinded to the histopathology. Thresholds of 50, 80, and 100% and delayed enhancement were independently assessed with CAD. Lesions were rated as malignant or benign according to threshold and delayed enhancement only and in combination. Sensitivities, specificities, and negative predictive values (NPV) were determined for CAD assessments versus pathology. Initial MRI BI-RADS interpretation without CAD versus CAD assessments were compared using paired binary diagnostic tests. Results: Threshold levels for lesion enhancement were: 50% to include all malignant (and all benign) lesions; and 100% for all invasive cancer and high-grade DCIS. Combined use of threshold and enhancement patterns for CAD assessment was best (73% sensitivity, 56% specificity and 76% NPV for all cancer). Sensitivities and NPV were better for invasive cancer (100%/100%) than for all malignancies (54%/76%). Radiologists' MRI interpretation was more sensitive than CAD (p = 0.05), but less specific (p = 0.001) for cancer detection. Conclusion: The breast MRI CAD system used could not improve the radiologists' accuracy for distinguishing all malignant from benign lesions, due to the poor sensitivity for DCIS detection.

  19. Format conversion between CAD data and GIS data based on ArcGIS

    Science.gov (United States)

    Xie, Qingqing; Wei, Bo; Zhang, Kailin; Wang, Zhichao

    2015-12-01

    To make full use of the data resources and realize a sharing for the different types of data in different industries, a method of format conversion between CAD data and GIS data based on ArcGIS was proposed. To keep the integrity of the converted data, some key steps to process CAD data before conversion were made in AutoCAD. For examples, deleting unnecessary elements such as title, border and legend avoided the appearance of unnecessary elements after conversion, as layering data again by a national standard avoided the different types of elements to appear in a same layer after conversion. In ArcGIS, converting CAD data to GIS data was executed by the correspondence of graphic element classification between AutoCAD and ArcGIS. In addition, an empty geographic database and feature set was required to create in ArcGIS for storing the text data of CAD data. The experimental results show that the proposed method avoids a large amount of editing work in data conversion and maintains the integrity of spatial data and attribute data between before and after conversion.

  20. CAD-based automatic modeling method for Geant4 geometry model through MCAM

    International Nuclear Information System (INIS)

    Wang, D.; Nie, F.; Wang, G.; Long, P.; LV, Z.

    2013-01-01

    The full text of publication follows. Geant4 is a widely used Monte Carlo transport simulation package. Before calculating using Geant4, the calculation model need be established which could be described by using Geometry Description Markup Language (GDML) or C++ language. However, it is time-consuming and error-prone to manually describe the models by GDML. Automatic modeling methods have been developed recently, but there are some problems that exist in most present modeling programs, specially some of them were not accurate or adapted to specifically CAD format. To convert the GDML format models to CAD format accurately, a Geant4 Computer Aided Design (CAD) based modeling method was developed for automatically converting complex CAD geometry model into GDML geometry model. The essence of this method was dealing with CAD model represented with boundary representation (B-REP) and GDML model represented with constructive solid geometry (CSG). At first, CAD model was decomposed to several simple solids which had only one close shell. And then the simple solid was decomposed to convex shell set. Then corresponding GDML convex basic solids were generated by the boundary surfaces getting from the topological characteristic of a convex shell. After the generation of these solids, GDML model was accomplished with series boolean operations. This method was adopted in CAD/Image-based Automatic Modeling Program for Neutronics and Radiation Transport (MCAM), and tested with several models including the examples in Geant4 install package. The results showed that this method could convert standard CAD model accurately, and can be used for Geant4 automatic modeling. (authors)

  1. Solid modeling and applications rapid prototyping, CAD and CAE theory

    CERN Document Server

    Um, Dugan

    2016-01-01

    The lessons in this fundamental text equip students with the theory of Computer Assisted Design (CAD), Computer Assisted Engineering (CAE), the essentials of Rapid Prototyping, as well as practical skills needed to apply this understanding in real world design and manufacturing settings. The book includes three main areas: CAD, CAE, and Rapid Prototyping, each enriched with numerous examples and exercises. In the CAD section, Professor Um outlines the basic concept of geometric modeling, Hermite and Bezier Spline curves theory, and 3-dimensional surface theories as well as rendering theory. The CAE section explores mesh generation theory, matrix notion for FEM, the stiffness method, and truss Equations. And in Rapid Prototyping, the author illustrates stereo lithographic theory and introduces popular modern RP technologies. Solid Modeling and Applications: Rapid Prototyping, CAD and CAE Theory is ideal for university students in various engineering disciplines as well as design engineers involved in product...

  2. Definition, translation and application of user-oriented languages as extensions of PL/1 in the CAD-systems REGENT

    International Nuclear Information System (INIS)

    Enderle, G.

    1975-09-01

    The integrated CAD-system REGENT serves for modular development of programs for different application areas, for management of data storage and data transfer and easy and safe application of programs by means of user-oriented languages. Programs, data and language for an application area form a REGENT-subsystem. The problem language system of REGENT, PLS (Problem Language System), provides facilities for the development of a problem oriented language for every subsystem as extensions of the base language PL/1. In this paper the translation of problem oriented languages by a precompiler into PL/1 and the definition of language extensions and datastructures for subsystems are described. Development and application of the language for a fluiddynamic-subsystem is shown. (orig.) [de

  3. The TorR High-Affinity Binding Site Plays a Key Role in Both torR Autoregulation and torCAD Operon Expression in Escherichia coli

    OpenAIRE

    Ansaldi, Mireille; Simon, Gwénola; Lepelletier, Michèle; Méjean, Vincent

    2000-01-01

    In the presence of trimethylamine N-oxide (TMAO), the TorS-TorR two-component regulatory system induces the torCAD operon, which encodes the TMAO respiratory system of Escherichia coli. The sensor protein TorS detects TMAO and transphosphorylates the response regulator TorR which, in turn, activates transcription of torCAD. The torR gene and the torCAD operon are divergently transcribed, and the short torR-torC intergenic region contains four direct repeats (the tor boxes) which proved to be ...

  4. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD

  5. Micro-relay technology for energy-efficient integrated circuits

    CERN Document Server

    Kam, Hei

    2015-01-01

    This book describes the design of relay-based circuit systems from device fabrication to circuit micro-architectures. This book is ideal for both device engineers as well as circuit system designers and highlights the importance of co-design across design hierarchies when optimizing system performance (in this case, energy-efficiency). This book is ideal for researchers and engineers focused on semiconductors, integrated circuits, and energy efficient electronics. This book also: ·         Covers microsystem fabrication, MEMS device design, circuit design, circuit micro-architecture, and CAD ·         Describes work previously done in the field and also lays the groundwork and criteria for future energy-efficient device and system design ·         Maximizes reader insights into the design and modeling of micro-relay, micro-relay reliability, integrated circuit design with micro-relays, and more

  6. Utilização do AutoCAD 2004 para quantificação de pesquisas usando fotomicrografias eletrônicas AutoCAD 2004 to quantify electron-photomicrography

    Directory of Open Access Journals (Sweden)

    Carla Albertina Martins Almeida

    2007-08-01

    Full Text Available OBJETIVO: Avaliar o uso do programa AutoCAD 2004 para estudos quantitativos em microscopia eletrônica. MÉTODOS: A demonstração da utilização do AutoCAD 2004 foi feita em um modelo experimental de diabetes induzido em ratos, divididos em Grupo Controle (GC-10 animais e Grupo Diabético (GD - 10 animais, avaliados 1 mês depois da indução do diabetes. Os olhos foram removidos após o sacrifício dos animais e preparados para exame em microscópio eletrônico, tendo sido feitas fotografias dos vasos retinianos. Foi utilizado o programa AutoCAD2004 para avaliar a espessura da membrana basal dos vasos. Os resultados foram avaliados estatisticamente. RESULTADOS: Usando o método proposto foi possível realizar medidas quantitativas na membrana basal de vasos retinianos de ratos diabéticos. CONCLUSÃO: O AutoCAD 2004 se mostrou efetivo, seguro e de fácil utilização para a quantificação de fenômenos biológicos, sendo possível sugerir este meio para a realização de avaliações quantitativas em experimentos biológicos.OBJECTIVE: To determine if the AutoCAD 2004 program is available to be used in quantitative research on electron microscopy. METHODS: A demonstrative of the AutoCAD2004 was done in an experimental model of diabetes induced in rats. The animals were divided by lot in control group animals (GC-10 animals and diabetic group (GD - 10 animals, evaluated 1 month after the diabetes induction. The eyes were removed after sacrifice and prepared to electron microscopy. The retina was photographed and the AutoCAD2004 program was used to measure the basal membrane of retina vessels. The results were submitted to statistical analysis. RESULTS: The AutoCAD2004 was effective to obtain quantitative measures from the basal membrane of retina vessels and there were no difference between the studied groups. CONCLUSION: The AutoCAD2004 was effective, safe and easy to apply to quantify biological parameters, which allowed suggest it to

  7. A visual LISP program for voxelizing AutoCAD solid models

    Science.gov (United States)

    Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz

    2015-01-01

    AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.

  8. Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

    Science.gov (United States)

    Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna

    2015-11-01

    The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate

  9. RayTrace: A Simplified Ray Tracing Software for use in AutoCad

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter; Tang, C.K.

    2005-01-01

    A design aid tool for testing and development of daylighting systems was developed. A simplified ray tracing software was programmed in Lisp for AutoCad. Only fully specularly reflective, fully transparent and fully absorbant surfaces can be defined in the software. The software is therefore best...

  10. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    Science.gov (United States)

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  11. Discoloration of various CAD/CAM blocks after immersion in coffee

    Directory of Open Access Journals (Sweden)

    Sasipin Lauvahutanon

    2017-02-01

    Full Text Available Objectives This study evaluated color differences (ΔEs and translucency parameter changes (ΔTPs of various computer-aided design/computer-aided manufacturing (CAD/CAM blocks after immersion in coffee. Materials and Methods Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L*a*b* values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6. The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05. The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent. The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC. There was no significant correlation between ΔEs and water sorption or solubility in water. Conclusions The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  12. Different Routes for Conifer- and Sinapaldehyde and Higher Saccharification upon Deficiency in the Dehydrogenase CAD11[OPEN

    Science.gov (United States)

    Laurans, Françoise; Foster, Cliff; Légée, Frédéric

    2017-01-01

    In the search for renewable energy sources, genetic engineering is a promising strategy to improve plant cell wall composition for biofuel and bioproducts generation. Lignin is a major factor determining saccharification efficiency and, therefore, is a prime target to engineer. Here, lignin content and composition were modified in poplar (Populus tremula × Populus alba) by specifically down-regulating CINNAMYL ALCOHOL DEHYDROGENASE1 (CAD1) by a hairpin-RNA-mediated silencing approach, which resulted in only 5% residual CAD1 transcript abundance. These transgenic lines showed no biomass penalty despite a 10% reduction in Klason lignin content and severe shifts in lignin composition. Nuclear magnetic resonance spectroscopy and thioacidolysis revealed a strong increase (up to 20-fold) in sinapaldehyde incorporation into lignin, whereas coniferaldehyde was not increased markedly. Accordingly, ultra-high-performance liquid chromatography-mass spectrometry-based phenolic profiling revealed a more than 24,000-fold accumulation of a newly identified compound made from 8-8 coupling of two sinapaldehyde radicals. However, no additional cinnamaldehyde coupling products could be detected in the CAD1-deficient poplars. Instead, the transgenic lines accumulated a range of hydroxycinnamate-derived metabolites, of which the most prominent accumulation (over 8,500-fold) was observed for a compound that was identified by purification and nuclear magnetic resonance as syringyl lactic acid hexoside. Our data suggest that, upon down-regulation of CAD1, coniferaldehyde is converted into ferulic acid and derivatives, whereas sinapaldehyde is either oxidatively coupled into S′(8-8)S′ and lignin or converted to sinapic acid and derivatives. The most prominent sink of the increased flux to hydroxycinnamates is syringyl lactic acid hexoside. Furthermore, low-extent saccharification assays, under different pretreatment conditions, showed strongly increased glucose (up to +81%) and xylose

  13. CAD And Distributed Manufacturing Solutions for Pellet Boiler Producers

    Directory of Open Access Journals (Sweden)

    Timur Mamut

    2016-12-01

    Full Text Available The paper is summarizing the research activities that had been carried out for defining an appropriate manufacturing concept and the system architecture for a manufacturing plant of pellet boilers. The concept has been validated through the implementation of a solution of computer integrated manufacturing that includes a CAD platform and a CAM facility including laser cutting machines, rolling and welding machines and advanced technologies for assembly, quality control and testing.

  14. Investigation and evaluation into the usability of human-computer interfaces using a typical CAD system

    Energy Technology Data Exchange (ETDEWEB)

    Rickett, J D

    1987-01-01

    This research program covers three topics relating to the human-computer interface namely, voice recognition, tools and techniques for evaluation, and user and interface modeling. An investigation into the implementation of voice-recognition technologies examines how voice recognizers may be evaluated in commercial software. A prototype system was developed with the collaboration of FEMVIEW Ltd. (marketing a CAD package). A theoretical approach to evaluation leads to the hypothesis that human-computer interaction is affected by personality, influencing types of dialogue, preferred methods for providing helps, etc. A user model based on personality traits, or habitual-behavior patterns (HBP) is presented. Finally, a practical framework is provided for the evaluation of human-computer interfaces. It suggests that evaluation is an integral part of design and that the iterative use of evaluation techniques throughout the conceptualization, design, implementation and post-implementation stages will ensure systems that satisfy the needs of the users and fulfill the goal of usability.

  15. Complete PCB design using OrCAD capture and PCB editor

    CERN Document Server

    Mitzner, Kraig

    2009-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Editor. Capture is used to build the schematic diagram of the circuit, and Editor is used to design the circuit board so that it can be manufactured. The book is written for both students and practicing engineers who need in-depth instruction on how to use the software, and who need background knowledge of the PCB design process. KEY FEATURES:* Beginning to end cove

  16. AutoCAD electrical 2013 for electrical control designers

    CERN Document Server

    Tickoo, Sham; CADCIM Technologies

    2013-01-01

    The AutoCAD Electrical 2013 for Electrical Control Designers textbook has been written to assist the engineering students and the practicing designers learn the application of various AutoCAD Electrical tools and options for creating electrical control designs. After reading this textbook, the users will be able to create professional electrical-control drawings easily and effectively. Moreover, the users will be able to automate various control engineering tasks such as building circuits, numbering wires, creating bills of materials, and many more. The textbook takes the users across a wide spectrum of electrical control drawings through progressive examples and numerous illustrations and exercises, thereby making it an ideal guide for both the novice and the advanced users. Salient Features of the Textbook Consists of 14 chapters that are organized in a pedagogical sequence covering various tools and features of AutoCAD Electrical such as schematic drawings, parametric and non-parametric PLC modules, Circu...

  17. AutoCAD electrical 2016 for electrical control designers

    CERN Document Server

    Tickoo, Sham

    2016-01-01

    The AutoCAD Electrical 2016 for Electrical Control Designers textbook has been written to assist the engineering students and the practicing designers who are new to AutoCAD Electrical. Using this textbook, the readers can learn the application of basic tools required for creating professional electrical control drawings with the help of AutoCAD Electrical. Keeping in view the varied requirements of the users, this textbook covers a wide range of tools and features such as schematic drawings, Circuit Builder, panel drawings, parametric and nonparametric PLC modules, stand-alone PLC I/O points, ladder diagrams, point-to-point wiring diagrams, report generation, creation of symbols, and so on. This will help the readers to create electrical drawings easily and effectively. Special emphasis has been laid on the introduction of concepts, which have been explained using text and supported with graphical examples. The examples and tutorials used in this book ensure that the users can relate the information provided...

  18. Marginal adaptation of CAD-CAM onlays: Influence of preparation design and impression technique.

    Science.gov (United States)

    Lima, Fernanda Ferruzzi; Neto, Constantino Fernandes; Rubo, José H; Santos, Gildo Coelho; Moraes Coelho Santos, Maria Jacinta

    2018-03-15

    Factors that may affect the marginal adaptation of computer-aided design and computer-aided manufacturing (CAD-CAM) restorations include preparation design, impression technique, and CAD-CAM system. The influence of impression technique and preparation design on CAD-CAM partial coverage restorations has not been fully addressed. The purpose of this in vitro study was to investigate the influence of direct and indirect digital impression techniques and 2 preparation designs on the marginal adaptation of CAD-CAM onlays. Two mesio-occlusal buccal onlay preparations with reduction of the mesiobuccal cusp were made: conventional preparation (CP) with a 1.2-mm modified shoulder margin and modified preparation (MP) flat cuspal reduction without shoulder. Virtual models were generated from each preparation by using a digital scanner (BlueCam; Dentsply Sirona) from the plastic teeth (direct digital impression) or from the stone dies (indirect digital impression). Onlays were designed using a CAD-CAM system (CEREC 4.0; Dentsply Sirona), and nanoceramic resin blocks (Lava Ultimate Restorative; 3M ESPE) were milled using the CEREC MCX milling machine. Marginal discrepancy was evaluated using an optical stereomicroscope at ×25 magnification in 18 locations distributed along the margins of the preparation. The data were analyzed by using 3-way ANOVA followed by the Tukey HSD test (α=.05). CP presented a statistically significant reduced average marginal adaptation (59 ±50 μm) than did MP (69 ±58 μm) (Pmarginal discrepancy in the mesial and buccal locations of MP when compared with CP. Regarding impression techniques, the buccal location presented the smallest average marginal discrepancy in restorations fabricated with indirect impression when compared with direct impression (42 ±33 μm and 60 ±39 μm) (Pmargin presented improved marginal adaptation compared with modified preparation with flat cuspal reduction. Direct and indirect digital impression techniques produced

  19. Structure, functional characterization, and evolution of the dihydroorotase domain of human CAD.

    Science.gov (United States)

    Grande-García, Araceli; Lallous, Nada; Díaz-Tejada, Celsa; Ramón-Maiques, Santiago

    2014-02-04

    Upregulation of CAD, the multifunctional protein that initiates and controls the de novo biosynthesis of pyrimidines in animals, is essential for cell proliferation. Deciphering the architecture and functioning of CAD is of interest for its potential usage as an antitumoral target. However, there is no detailed structural information about CAD other than that it self-assembles into hexamers of ∼1.5 MDa. Here we report the crystal structure and functional characterization of the dihydroorotase domain of human CAD. Contradicting all assumptions, the structure reveals an active site enclosed by a flexible loop with two Zn²⁺ ions bridged by a carboxylated lysine and a third Zn coordinating a rare histidinate ion. Site-directed mutagenesis and functional assays prove the involvement of the Zn and flexible loop in catalysis. Comparison with homologous bacterial enzymes supports a reclassification of the DHOase family and provides strong evidence against current models of the architecture of CAD. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. CAD/CAM-assisted breast reconstruction

    International Nuclear Information System (INIS)

    Melchels, Ferry; Hutmacher, Dietmar Werner; Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten; Warne, David; Barry, Mark; Ong, Fook Rhu; Chong, Woon Shin

    2011-01-01

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  1. A robust and efficient approach to detect 3D rectal tubes from CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Yang Xiaoyun; Slabaugh, Greg [Medicsight PLC, Kensington Centre, 66 Hammersmith Road, London (United Kingdom)

    2011-11-15

    Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

  2. A robust and efficient approach to detect 3D rectal tubes from CT colonography

    International Nuclear Information System (INIS)

    Yang Xiaoyun; Slabaugh, Greg

    2011-01-01

    Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

  3. Wind Turbine Blade CAD Models Used as Scaffolding Technique to Teach Design Engineers

    Science.gov (United States)

    Irwin, John

    2013-01-01

    The Siemens PLM CAD software NX is commonly used for designing mechanical systems, and in complex systems such as the emerging area of wind power, the ability to have a model controlled by design parameters is a certain advantage. Formula driven expressions based on the amount of available wind in an area can drive the amount of effective surface…

  4. Digital microscopic evaluation of vertical marginal discrepancies of CAD/CAM fabricated zirconia cores.

    Science.gov (United States)

    Habib, Syed Rashid

    2018-05-18

    The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital microscope. A total of 60 specimens were prepared and randomly divided into five groups (n=12 each) using the following systems: Ceramill Motion 2 (CM, Amanngirrbach, Germany); Weiland (WI, Ivoclar Vivadent, USA); Cerec (CS, Sirona Dental, USA); Zirkonzahn (ZZ, Gmbh Bruneck, Italy) and Cad4dent (CD, Canada). The specimens were numbered and the vertical marginal discrepancies were evaluated with a digital microscope at 50× magnification. A one-way analysis of variance showed a statistically significant difference (p=0.002) between the groups. The CM group exhibited the lowest values for the marginal gaps (31.30±15.12 μm), while the ZZ group exhibited the highest values for the marginal gaps (44.83±28.76 μm) compared to other groups. A post hoc Tukey's test for multiple comparisons between the experimental groups showed a statistically significant difference (p<0.05) between the group CM and group CD with group ZZ. The rest of the groups showed no significant differences between them. Variations in the values were observed for the four sites measured with the highest and the least mean marginal gap value of 43.19±23.84 μm and 32.49±12.21 μm for buccal and lingual sites, respectively. Variations existed in the marginal discrepancy values for the CAD/CAM systems investigated in the study. Vertical marginal discrepancy values observed for various systems investigated in the study were well within the clinically acceptable range.

  5. The Nucleotide Synthesis Enzyme CAD Inhibits NOD2 Antibacterial Function in Human Intestinal Epithelial Cells

    Science.gov (United States)

    Richmond, Amy L.; Kabi, Amrita; Homer, Craig R.; García, Noemí Marina; Nickerson, Kourtney P.; NesvizhskiI, Alexey I.; Sreekumar, Arun; Chinnaiyan, Arul M.; Nuñez, Gabriel; McDonald, Christine

    2013-01-01

    BACKGROUND & AIMS Polymorphisms that reduce the function of nucleotide-binding oligomerization domain (NOD)2, a bacterial sensor, have been associated with Crohn’s disease (CD). No proteins that regulate NOD2 activity have been identified as selective pharmacologic targets. We sought to discover regulators of NOD2 that might be pharmacologic targets for CD therapies. METHODS Carbamoyl phosphate synthetase/ aspartate transcarbamylase/dihydroorotase (CAD) is an enzyme required for de novo pyrimidine nucleotide synthesis; it was identified as a NOD2-interacting protein by immunoprecipitation-coupled mass spectrometry. CAD expression was assessed in colon tissues from individuals with and without inflammatory bowel disease by immunohistochemistry. The interaction between CAD and NOD2 was assessed in human HCT116 intestinal epithelial cells by immunoprecipitation, immunoblot, reporter gene, and gentamicin protection assays. We also analyzed human cell lines that express variants of NOD2 and the effects of RNA interference, overexpression and CAD inhibitors. RESULTS CAD was identified as a NOD2-interacting protein expressed at increased levels in the intestinal epithelium of patients with CD compared with controls. Overexpression of CAD inhibited NOD2-dependent activation of nuclear factor κB and p38 mitogen-activated protein kinase, as well as intracellular killing of Salmonella. Reduction of CAD expression or administration of CAD inhibitors increased NOD2-dependent signaling and antibacterial functions of NOD2 variants that are and are not associated with CD. CONCLUSIONS The nucleotide synthesis enzyme CAD is a negative regulator of NOD2. The antibacterial function of NOD2 variants that have been associated with CD increased in response to pharmacologic inhibition of CAD. CAD is a potential therapeutic target for CD. PMID:22387394

  6. Design system for in-vessel mainipulator of fusion reactor 'DESIM'

    International Nuclear Information System (INIS)

    Adachi, Junihci; Kobayashi, Takeshi; Ise, Hideo; Sato, Keisuke; Matsuda, Hirotsugu

    1989-01-01

    A computer aided design system 'DESIM' for the in-vessel manipulators of nuclear fusion reactors has been developed to design the manipulators efficiently. The DESIM consists of the following subsystems: (1) the design system for arm mechanisms to realize optimum manipulation performance in the specified workspace; (2) the robot simulator to study manipulator movement, postures and interference problems; (3) the CAD system which is used to define the structure object data for robots, and the interface system for the data conversion from the CAD system to the robot simulator. The DESIM has been used to design the in-vessel manipulator for the Fusion Experimental Reactor (FER) to confirm the effectiveness. (author)

  7. Numerical Analysis of Turbulent Flow around Tube Bundle by Applying CAD Best Practice Guideline

    International Nuclear Information System (INIS)

    Lee, Gong Hee; Bang, Young Seok; Woo, Sweng Woong; Cheng, Ae Ju

    2013-01-01

    In this study, the numerical analysis of a turbulent flow around both a staggered and an incline tube bundle was conducted using Annoys Cfx V. 13, a commercial CAD software. The flow was assumed to be steady, incompressible, and isothermal. According to the CAD Best Practice Guideline, the sensitivity study for grid size, accuracy of the discretization scheme for convection term, and turbulence model was conducted, and its result was compared with the experimental data to estimate the applicability of the CAD Best Practice Guideline. It was concluded that the CAD Best Practice Guideline did not always guarantee an improvement in the prediction performance of the commercial CAD software in the field of tube bundle flow

  8. Integrated approach for fusion multi-physics coupled analyses based on hybrid CAD and mesh geometries

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Yuefeng, E-mail: yuefeng.qiu@kit.edu; Lu, Lei; Fischer, Ulrich

    2015-10-15

    Highlights: • Integrated approach for neutronics, thermal and structural analyses was developed. • MCNP5/6, TRIPOLI-4 were coupled with CFX, Fluent and ANSYS Workbench. • A novel meshing approach has been proposed for describing MC geometry. - Abstract: Coupled multi-physics analyses on fusion reactor devices require high-fidelity neutronic models, and flexible, accurate data exchanging between various calculation codes. An integrated coupling approach has been developed to enable the conversion of CAD, mesh, or hybrid geometries for Monte Carlo (MC) codes MCNP5/6, TRIPOLI-4, and translation of nuclear heating data for CFD codes Fluent, CFX and structural mechanical software ANSYS Workbench. The coupling approach has been implemented based on SALOME platform with CAD modeling, mesh generation and data visualization capabilities. A novel meshing approach has been developed for generating suitable meshes for MC geometry descriptions. The coupling approach has been concluded to be reliable and efficient after verification calculations of several application cases.

  9. Microcomputer Simulated CAD for Engineering Graphics.

    Science.gov (United States)

    Huggins, David L.; Myers, Roy E.

    1983-01-01

    Describes a simulated computer-aided-graphics (CAD) program at The Pennsylvania State University. Rationale for the program, facilities, microcomputer equipment (Apple) used, and development of a software package for simulating applied engineering graphics are considered. (JN)

  10. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    International Nuclear Information System (INIS)

    Weinhorst, Bastian; Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng; Wilson, Paul

    2015-01-01

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  11. Comparative assessment of different approaches for the use of CAD geometry in Monte Carlo transport calculations

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Eggenstein-Leopoldshafen (Germany); Wilson, Paul [University of Wisconsin-Madison, Computational Nuclear Engineering Research Group, Madison, WI (United States)

    2015-10-15

    Highlights: • Comparison of different approaches for the use of CAD geometry for Monte Carlo transport calculations. • Comparison with regard to user-friendliness and computation performance. • Three approaches, namely conversion with McCad, unstructured mesh feature of MCN6 and DAGMC. • Installation most complex for DAGMC, model preparation worst for McCad, computation performance worst for MCNP6. • Installation easiest for McCad, model preparation best for MCNP6, computation speed fastest for McCad. - Abstract: Computer aided design (CAD) is an important industrial way to produce high quality designs. Therefore, CAD geometries are in general used for engineering and the design of complex facilities like the ITER tokamak. Although Monte Carlo codes like MCNP are well suited to handle the complex 3D geometry of ITER for transport calculations, they rely on their own geometry description and are in general not able to directly use the CAD geometry. In this paper, three different approaches for the use of CAD geometries with MCNP calculations are investigated and assessed with regard to calculation performance and user-friendliness. The first method is the conversion of the CAD geometry into MCNP geometry employing the conversion software McCad developed by KIT. The second approach utilizes the MCNP6 mesh geometry feature for the particle tracking and relies on the conversion of the CAD geometry into a mesh model. The third method employs DAGMC, developed by the University of Wisconsin-Madison, for the direct particle tracking on the CAD geometry using a patched version of MCNP. The obtained results show that each method has its advantages depending on the complexity and size of the model, the calculation problem considered, and the expertise of the user.

  12. Different Routes for Conifer- and Sinapaldehyde and Higher Saccharification upon Deficiency in the Dehydrogenase CAD1.

    Science.gov (United States)

    Van Acker, Rebecca; Déjardin, Annabelle; Desmet, Sandrien; Hoengenaert, Lennart; Vanholme, Ruben; Morreel, Kris; Laurans, Françoise; Kim, Hoon; Santoro, Nicholas; Foster, Cliff; Goeminne, Geert; Légée, Frédéric; Lapierre, Catherine; Pilate, Gilles; Ralph, John; Boerjan, Wout

    2017-11-01

    In the search for renewable energy sources, genetic engineering is a promising strategy to improve plant cell wall composition for biofuel and bioproducts generation. Lignin is a major factor determining saccharification efficiency and, therefore, is a prime target to engineer. Here, lignin content and composition were modified in poplar ( Populus tremula × Populus alba ) by specifically down-regulating CINNAMYL ALCOHOL DEHYDROGENASE1 ( CAD1 ) by a hairpin-RNA-mediated silencing approach, which resulted in only 5% residual CAD1 transcript abundance. These transgenic lines showed no biomass penalty despite a 10% reduction in Klason lignin content and severe shifts in lignin composition. Nuclear magnetic resonance spectroscopy and thioacidolysis revealed a strong increase (up to 20-fold) in sinapaldehyde incorporation into lignin, whereas coniferaldehyde was not increased markedly. Accordingly, ultra-high-performance liquid chromatography-mass spectrometry-based phenolic profiling revealed a more than 24,000-fold accumulation of a newly identified compound made from 8-8 coupling of two sinapaldehyde radicals. However, no additional cinnamaldehyde coupling products could be detected in the CAD1-deficient poplars. Instead, the transgenic lines accumulated a range of hydroxycinnamate-derived metabolites, of which the most prominent accumulation (over 8,500-fold) was observed for a compound that was identified by purification and nuclear magnetic resonance as syringyl lactic acid hexoside. Our data suggest that, upon down-regulation of CAD1 , coniferaldehyde is converted into ferulic acid and derivatives, whereas sinapaldehyde is either oxidatively coupled into S'(8-8)S' and lignin or converted to sinapic acid and derivatives. The most prominent sink of the increased flux to hydroxycinnamates is syringyl lactic acid hexoside. Furthermore, low-extent saccharification assays, under different pretreatment conditions, showed strongly increased glucose (up to +81%) and

  13. Innovation problems of new technologies - the introduction of CAD to mechnical engineering

    Energy Technology Data Exchange (ETDEWEB)

    Riehm, U; Rader, M

    1982-01-01

    The introduction of CAD (computer aided design) is accompanied by uncertainties in the estimation of the needs, the effectivity and the consequence of the application of CAD. Similar uncertainties have also been observed in the past during the introduction of NC-tooling machines. These problems can be solved by a parallel scientific evaluation of the experience made. This is the main purpose of a social science study accomaniing the introduction of CAD, which is presented here.

  14. Introduction to AutoCAD 2013 2D and 3D design

    CERN Document Server

    Yarwood, Alf

    2013-01-01

    Master the complexities of the world's bestselling 2D and 3D software with Alf Yarwood's Introduction to AutoCAD 2013. Ideally suited to new users of AutoCAD, this book will be a useful resource for drawing modules in both vocational and introductory undergraduate courses in engineering and construction.Alf Yarwood has once again produced a comprehensive, step-by-step introduction to the latest release of AutoCAD. Covering all the basic principles and acting as an introduction to 2D drawing, it also contains extensive coverage of all 3D topics, including 3D solid modelling a

  15. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  16. Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.

    Science.gov (United States)

    Stawarczyk, Bogna; Özcan, Mutlu; Trottmann, Albert; Schmutz, Felix; Roos, Malgorzata; Hämmerle, Christoph

    2013-05-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown. The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks. Wear specimens (N=42, n=6) were made from 5 CAD/CAM resins: ZENO PMMA (ZP), artBloc Temp (AT), Telio CAD (TC), Blanc High-class (HC), CAD-Temp (CT); 1 manually polymerized resin: Integral esthetic press (negative control group, IEP); and 1 glass-ceramic: VITA Mark II (positive control group, VM2). The specimens for the wear resistance were aged in a thermomechanical loading machine (49 N, 1.67 Hz, 5/50°C) with human enamel antagonists. The material loss of all specimens before, during, and after aging was evaluated with a 3DS profilometer. The measured material loss data of all tested groups were statistically evaluated with linear mixed model analysis (a=.05). Manually polymerized resin showed significantly higher material wear (P<.001) than all other tested groups. Glass-ceramic showed significantly lower wear values (P<.001) than CAD/CAM resins ZP, AT, HC, CT, and IES. CAD/CAM resin TC was not significantly different from the positive control group. Glass-ceramic showed the highest enamel wear values (P<.001) of all tested resins. No differences were found in the enamel wear among all resins. The glass-ceramic group showed damage in the form of cracks on the worn enamel surface in 50% of specimens. CAD/CAM resins showed lower wear rates than those conventionally polymerized. Only one CAD/CAM resin, TC, presented material wear values comparable with glass-ceramic. The tested glass-ceramic developed cracks in the enamel antagonist and showed the highest enamel wear values of all other tested groups. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  17. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    Science.gov (United States)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  18. Instant Autodesk AutoCAD 2014 customization with .NET

    CERN Document Server

    Nelson, Tom

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. An instruction-based guide with examples written in the C# programming language. VB.NET programmers can also take advantage of these examples by using one of the free conversion websites to convert the examples to VB.NET.Clear, step-by-step instructions and complete code examples illustrate the processes, making it easy to develop your own custom AutoCAD tools.This book is perfect if you are interested in customizing AutoCAD 2014 using the .NET API. You should have a basic familiari

  19. CAD system for quantifying emphysema severity based on multi-class classifier using CT image and spirometry information

    International Nuclear Information System (INIS)

    Nimura, Yukitaka; Mori, Kensaku; Kitasaka, Takayuki; Honma, Hirotoshi; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi

    2010-01-01

    Many diagnosis methods based on CT image processing are proposed for quantifying emphysema. The most of these diagnosis methods extract lesions as Low-Attenuation Areas (LAA) by simple threshold processing and evaluate their severity by calculating the LAA (LAA%) in the lung. However, pulmonary emphysema is diagnosed by not only the LAA but also the changes of pulmonary blood vessel and the spirometric measurements. This paper proposes a novel computer-aided detection (CAD) system for quantifying emphysema by combining spirometric measurements and results of CT image processing. The experimental results revealed that the accuracy rate of the proposed method was 78.3%. It is 13.1% improvement compared with the method based on only the LAA%. (author)

  20. Designing a combined casting mold for manufacture of a gasoline centrifugal pump body using CAD/CAM-systems

    Science.gov (United States)

    Galin, N. E.; Ogol, I. I.; Chervach, Yu B.; Dammer, V. Kh; Ru, Jia Hong

    2017-02-01

    The present paper examines designing of a combined casting mold for manufacture of a gasoline centrifugal pump body. The paper offers technological solutions for obtaining high quality castings at the testing stage of the finished mold. The paper is intended for practical use and prepared by order of JSC ‘Tomsk Electrical Engineering Plant’ using software and equipment of the department ‘Technologies of Computer-Aided Machinery Manufacturing’ of the Tomsk Polytechnic University (TPU) under the economic contract within state import substitution program. In preparing the paper, CAD/CAM-systems KOMPAS-3D and PowerMILL were used. In 2015, the designed casting mold was introduced into the production process at JSC ‘Tomsk Electrical Engineering Plant’.

  1. Marginal and internal fit of nano-composite CAD/CAM restorations

    Directory of Open Access Journals (Sweden)

    So-Hyun Park

    2016-02-01

    Full Text Available Objectives The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods A full veneer crown and an mesio-occluso-distal (MOD inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU and experimental nano-composite CAD/CAM blocks (EB under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000. In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001. Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000. Conclusions The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

  2. A CAD system for cerebral glioma based on texture features in DT-MR images

    Energy Technology Data Exchange (ETDEWEB)

    De Nunzio, G., E-mail: giorgio.denunzio@unisalento.it [Dept. of Materials Science, University of Salento, Via Monteroni, 73100 Lecce (Italy); Pastore, G. [PO ' Vito Fazzi' , UOC Fisica Sanitaria, Lecce (Italy); Donativi, M. [Dept. of Materials Science, University of Salento, Via Monteroni, 73100 Lecce (Italy); Castellano, A.; Falini, A. [Neuroradiology Unit and CERMAC Scientific Institute and University Vita-Salute San Raffaele, Milan (Italy)

    2011-08-21

    Tumor cells in cerebral glioma invade the surrounding tissues preferentially along white-matter tracts, spreading beyond the abnormal area seen on conventional MR images. Diffusion Tensor Imaging can reveal large peritumoral abnormalities in gliomas, which are not apparent on MRI. Our aim was to characterize pathological vs. healthy tissue in DTI datasets by 3D statistical Texture Analysis, developing an automatic segmentation technique (CAD, Computer Assisted Detection) for cerebral glioma based on a supervised classifier (an artificial neural network). A Matlab GUI (Graphical User Interface) was created to help the physician in the assisted diagnosis process and to optimize interactivity with the segmentation system, especially for patient follow-up during chemotherapy, and for preoperative assessment of tumor extension. Preliminary tissue classification results were obtained for the p map (the calculated area under the ROC curve, AUC, was 0.96) and the FA map (AUC=0.98). Test images were automatically segmented by tissue classification; manual and automatic segmentations were compared, showing good concordance.

  3. A CAD system for cerebral glioma based on texture features in DT-MR images

    International Nuclear Information System (INIS)

    De Nunzio, G.; Pastore, G.; Donativi, M.; Castellano, A.; Falini, A.

    2011-01-01

    Tumor cells in cerebral glioma invade the surrounding tissues preferentially along white-matter tracts, spreading beyond the abnormal area seen on conventional MR images. Diffusion Tensor Imaging can reveal large peritumoral abnormalities in gliomas, which are not apparent on MRI. Our aim was to characterize pathological vs. healthy tissue in DTI datasets by 3D statistical Texture Analysis, developing an automatic segmentation technique (CAD, Computer Assisted Detection) for cerebral glioma based on a supervised classifier (an artificial neural network). A Matlab GUI (Graphical User Interface) was created to help the physician in the assisted diagnosis process and to optimize interactivity with the segmentation system, especially for patient follow-up during chemotherapy, and for preoperative assessment of tumor extension. Preliminary tissue classification results were obtained for the p map (the calculated area under the ROC curve, AUC, was 0.96) and the FA map (AUC=0.98). Test images were automatically segmented by tissue classification; manual and automatic segmentations were compared, showing good concordance.

  4. Techniques for CAD reconstruction of 'as-built' environments and application to preparing for dismantling of plants

    International Nuclear Information System (INIS)

    Pot, J.; Levesque, P.

    1997-01-01

    Electricite de France is using CAD-generated numeric geometrical models to simulate maintenance operations and enable optimizing maintenance procedures. These models are also used to program the machines or robots for certain servicing procedures. They are used in the operator interfaces for robot control, and provide the operator with virtual cameras or enable generating specific information (such as virtual force feedback). Even more recently, CAD models have been integrated in what is known as 'virtual reality' software, giving the operators a sensation of 'immersion' in a virtual universe. Depending on the need and on the type of results expected from the simulations, one needs more or less precise models of the environment in which work will be performed. EDF is using several techniques to get 'as-built' models of the environments. This article describes the SOISIC system, which is a 3D laser sensor widely used for environment data acquisition, associated with 3Dipsos software, for CAD model reconstruction. These techniques, and the applications subsequently developed formaintenance applications, can be used in preparing and carrying out dismantling operations: 'as-built' CAD modeling of the installation can be used in the preparatory phase, providing plans, simulating the varioussteps, calculating waste volumes, helping in optimization of waste management, etc. These models can also be used during the actual dismantling process, to program the machines or robots used, or in the robot or machinesupervisory system. Some of the presented techniques have been used in a room in the Brennilis plant, which is currently being dismantled. (orig.)

  5. Edge strength of CAD/CAM materials.

    Science.gov (United States)

    Pfeilschifter, Maria; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-05-16

    To investigate the edge force of CAD/CAM materials as a function of (a) material, (b) thickness, and (c) distance from the margin. Materials intended for processing with CAD/CAM were investigated: eight resin composites, one resin-infiltrated ceramic, and a clinically proven lithiumdisilicate ceramic (reference). To measure edge force (that is, load to failure/crack), plates (d = 1 mm) were fixed and loaded with a Vickers diamond indenter (1 mm/min, Zwick 1446) at a distance of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm from the edge. Edge force was defined as a loading force at a distance of 0.5 mm. The type of failure was determined. To investigate the influence of the thickness, all data were determined on 1-mm and 2-mm plates. To test the influence of bonding and an underlying dentin, individual 1-mm plates were bonded to a 1-mm-thick dentin-like (concerning modulus of elasticity) resin composite. For the 1-mm plates, edge force varied between 64.4 ± 24.2 N (Shofu Block HC) and 183.2 ± 63.3 N (ceramic reference), with significant (p ≤ 0.001) differences between the materials. For the 2-mm plates, values between 129.2 ± 32.5 N (Lava Ultimate) and 230.3 ± 67.5 N (Cerasmart) were found. Statistical comparison revealed no significant differences (p > 0.109) between the materials. Brilliant Crios (p = 0.023), Enamic (p = 0.000), Shofu Blocks HC (p = 0.009), and Grandio Bloc (p = 0.002) showed significantly different edge force between the 1-mm- and 2-mm-thick plates. The failure pattern was either cracking, (severe) chipping, or fracture. Material, material thickness, and distance from the edge impact the edge force of CAD/CAM materials. CAD/CAM materials should be carefully selected on the basis of their individual edge force and performance during milling. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. AsBuilt-image with photogrammetry and 3D-CAD

    International Nuclear Information System (INIS)

    Kamsties, K.D.

    1993-01-01

    Using the combined method of photogrammetry and 3D-CAD, one obtains an AsBuilt-model of a plant, e.g. of a nuclear power plant, which surpasses all conventional methods of documentation concerning graphic quality as well as the possibilities of evaluation by data processing. With the 3D-CAD-model a full representation of the plant e.g. for safety assessment (''On-screen inspection'') or as a basis for future re-planning is available in the office. (orig./DG) [de

  7. CT Colonography: Role of a second reader CAD paradigm in the initial training of radiologists

    International Nuclear Information System (INIS)

    Neri, Emanuele; Faggioni, Lorenzo; Regge, Daniele; Vagli, Paola; Turini, Francesca; Cerri, Francesca; Picano, Eugenia; Giusti, Sabina; Bartolozzi, Carlo

    2011-01-01

    Purpose: To evaluate the influence of CAD for the evaluation of CT colonography (CTC) datasets by inexperienced readers during the attendance of a dedicated hands-on training course. Method and materials: Twenty-seven radiologists inexperienced in CTC (11 with no CTC training at all, 16 having previously reviewed no more than 10 CTC cases overall) attended a hands-on training course based on direct teaching on fifteen workstations (four Advantage Windows 4.4 with Colon VCAR software, GE; six CADCOLON, Im3D; five ColonScreen (Toshiba/Voxar) with ColonCAD TM API, Medicsight). During the course, readers were instructed to analyze 26 CTC cases including 38 colonic lesions obtained through low-dose MDCT acquisitions, consisting of 12 polyps sized less than 6 mm, 9 polyps sized between 6 and 10 mm, 12 polyps sized between 11 mm and 30 mm, and 5 colonic masses sized >3 cm. CTC images were reviewed by each reader both in 2D and 3D mode, respectively by direct evaluation of native axial images and MPR reconstructions, and virtual endoscopy or dissected views. Each reader had 15 min time for assessing each dataset without CAD, after which results were compared with those provided by CAD software. Global rater sensitivity for each lesion size before and after CAD usage was compared by means of two-tailed Student's t test, while sensitivity of each single reader before and after CAD usage was assessed with the McNemar test. Results: For lesions sized 30 mm, sensitivity before CAD-assisted reading was 0.3556 ± 0.3105 and did not change after CAD usage (p = 1). Sensitivity of each single rater did not significantly differ before and after CAD for any lesion size category (McNemar test, p > 0.05). Specificity was not significantly different before and after CAD for any lesion size (>96% for all size categories). Conclusion: CAD usage led to increased overall sensitivity of inexperienced readers for all polyps sizes, except for lesions >30 mm, but sensitivity of individual raters

  8. Different Routes for Conifer- and Sinapaldehyde and Higher Saccharification upon Deficiency in the Dehydrogenase CAD1

    OpenAIRE

    Van Acker, Rebecca; Dejardin, Annabelle; Desmet, Sandrien; Hoengenaert, Lennart; Vanholme, Ruben; Morreel, Kris; Laurans, Françoise; Kim, Hoon; Santoro, Nicholas; Foster, Cliff; Goeminne, Geert; Legée, Frédéric; Lapierre, Catherine; Pilate, Gilles; Ralph, John

    2017-01-01

    In the search for renewable energy sources, genetic engineering is a promising strategy to improve plant cell wall composition for biofuel and bioproducts generation. Lignin is a major factor determining saccharification efficiency and, therefore, is a prime target to engineer. Here, lignin content and composition were modified in poplar (Populus tremula 3 Populus alba) by specifically down-regulating CINNAMYL ALCOHOL DEHYDROGENASE1 (CAD1) by a hairpin-RNA-mediated silencing approach, which r...

  9. The Z-cad dual fluorescent sensor detects dynamic changes between the epithelial and mesenchymal cellular states.

    Science.gov (United States)

    Toneff, M J; Sreekumar, A; Tinnirello, A; Hollander, P Den; Habib, S; Li, S; Ellis, M J; Xin, L; Mani, S A; Rosen, J M

    2016-06-17

    The epithelial to mesenchymal transition (EMT) has been implicated in metastasis and therapy resistance of carcinomas and can endow cancer cells with cancer stem cell (CSC) properties. The ability to detect cancer cells that are undergoing or have completed EMT has typically relied on the expression of cell surface antigens that correlate with an EMT/CSC phenotype. Alternatively these cells may be permanently marked through Cre-mediated recombination or through immunostaining of fixed cells. The EMT process is dynamic, and these existing methods cannot reveal such changes within live cells. The development of fluorescent sensors that mirror the dynamic EMT state by following the expression of bona fide EMT regulators in live cells would provide a valuable new tool for characterizing EMT. In addition, these sensors will allow direct observation of cellular plasticity with respect to the epithelial/mesenchymal state to enable more effective studies of EMT in cancer and development. We generated a lentiviral-based, dual fluorescent reporter system, designated as the Z-cad dual sensor, comprising destabilized green fluorescent protein containing the ZEB1 3' UTR and red fluorescent protein driven by the E-cadherin (CDH1) promoter. Using this sensor, we robustly detected EMT and mesenchymal to epithelial transition (MET) in breast cancer cells by flow cytometry and fluorescence microscopy. Importantly, we observed dynamic changes in cellular populations undergoing MET. Additionally, we used the Z-cad sensor to identify and isolate minor subpopulations of cells displaying mesenchymal properties within a population comprising predominately epithelial-like cells. The Z-cad dual sensor identified cells with CSC-like properties more effectively than either the ZEB1 3' UTR or E-cadherin sensor alone. The Z-cad dual sensor effectively reports the activities of two factors critical in determining the epithelial/mesenchymal state of carcinoma cells. The ability of this stably

  10. Reconstruction of Consistent 3d CAD Models from Point Cloud Data Using a Priori CAD Models

    Science.gov (United States)

    Bey, A.; Chaine, R.; Marc, R.; Thibault, G.; Akkouche, S.

    2011-09-01

    We address the reconstruction of 3D CAD models from point cloud data acquired in industrial environments, using a pre-existing 3D model as an initial estimate of the scene to be processed. Indeed, this prior knowledge can be used to drive the reconstruction so as to generate an accurate 3D model matching the point cloud. We more particularly focus our work on the cylindrical parts of the 3D models. We propose to state the problem in a probabilistic framework: we have to search for the 3D model which maximizes some probability taking several constraints into account, such as the relevancy with respect to the point cloud and the a priori 3D model, and the consistency of the reconstructed model. The resulting optimization problem can then be handled using a stochastic exploration of the solution space, based on the random insertion of elements in the configuration under construction, coupled with a greedy management of the conflicts which efficiently improves the configuration at each step. We show that this approach provides reliable reconstructed 3D models by presenting some results on industrial data sets.

  11. Auto MOC-A 2D neutron transport code for arbitrary geometry based on the method of characteristics and customization of AutoCAD

    International Nuclear Information System (INIS)

    Chen Qichang; Wu Hongchun; Cao Liangzhi

    2008-01-01

    A new 2D neutron transport code AutoMOC for arbitrary geometry has been developed. This code is based on the method of characteristics (MOCs) and the customization of AutoCAD. The MOC solves the neutron transport equation along characteristic lines. It is independent of the geometric shape of boundaries and regions. So theoretically, this method can be used to solve the neutron transport equation in highly complex geometries. However, it is important to describe the geometry and calculate intersection points of each characteristic line with every boundary and region in advance. In complex geometries, due to the complications of treating the arbitrary domain, the selection of geometric shapes and efficiency of ray tracing are generally limited. The geometry treatment through the customization of AutoCAD, a widely used computer-aided design software package, is given in this paper. Thanks to the powerful capability of AutoCAD, the description of arbitrary geometry becomes quite convenient. Moreover, with the language Visual Basic for Applications (VBAs), AutoCAD can be customized to carry out the ray tracing procedure with a high flexibility in geometry. The numerical results show that AutoMOC can solve 2D neutron transport problems in a complex geometry accurately and effectively

  12. Auto MOC-A 2D neutron transport code for arbitrary geometry based on the method of characteristics and customization of AutoCAD

    Energy Technology Data Exchange (ETDEWEB)

    Chen Qichang; Wu Hongchun [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an Shaanxi 710049 (China); Cao Liangzhi [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an Shaanxi 710049 (China)], E-mail: caolz@mail.xjtu.edu.cn

    2008-10-15

    A new 2D neutron transport code AutoMOC for arbitrary geometry has been developed. This code is based on the method of characteristics (MOCs) and the customization of AutoCAD. The MOC solves the neutron transport equation along characteristic lines. It is independent of the geometric shape of boundaries and regions. So theoretically, this method can be used to solve the neutron transport equation in highly complex geometries. However, it is important to describe the geometry and calculate intersection points of each characteristic line with every boundary and region in advance. In complex geometries, due to the complications of treating the arbitrary domain, the selection of geometric shapes and efficiency of ray tracing are generally limited. The geometry treatment through the customization of AutoCAD, a widely used computer-aided design software package, is given in this paper. Thanks to the powerful capability of AutoCAD, the description of arbitrary geometry becomes quite convenient. Moreover, with the language Visual Basic for Applications (VBAs), AutoCAD can be customized to carry out the ray tracing procedure with a high flexibility in geometry. The numerical results show that AutoMOC can solve 2D neutron transport problems in a complex geometry accurately and effectively.

  13. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening

    DEFF Research Database (Denmark)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR......) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were...... excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences...

  14. Selection of examples in case-based computer-aided decision systems

    International Nuclear Information System (INIS)

    Mazurowski, Maciej A; Zurada, Jacek M; Tourassi, Georgia D

    2008-01-01

    Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system's diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system's performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2-4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system.

  15. Chairside CAD/CAM materials. Part 3: Cyclic fatigue parameters and lifetime predictions.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Valladares, Diana; Petschelt, Anselm; Lohbauer, Ulrich

    2018-06-01

    Chemical and mechanical degradation play a key role on the lifetime of dental restorative materials. Therefore, prediction of their long-term performance in the oral environment should base on fatigue, rather than inert strength data, as commonly observed in the dental material's field. The objective of the present study was to provide mechanistic fatigue parameters of current dental CAD/CAM materials under cyclic biaxial flexure and assess their suitability in predicting clinical fracture behaviors. Eight CAD/CAM materials, including polycrystalline zirconia (IPS e.max ZirCAD), reinforced glasses (Vitablocs Mark II, IPS Empress CAD), glass-ceramics (IPS e.max CAD, Suprinity PC, Celtra Duo), as well as hybrid materials (Enamic, Lava Ultimate) were evaluated. Rectangular plates (12×12×1.2mm 3 ) with highly polished surfaces were prepared and tested in biaxial cyclic fatigue in water until fracture using the Ball-on-Three-Balls (B3B) test. Cyclic fatigue parameters n and A* were obtained from the lifetime data for each material and further used to build SPT diagrams. The latter were used to compare in-vitro with in-vivo fracture distributions for IPS e.max CAD and IPS Empress CAD. Susceptibility to subcritical crack growth under cyclic loading was observed for all materials, being more severe (n≤20) in lithium-based glass-ceramics and Vitablocs Mark II. Strength degradations of 40% up to 60% were predicted after only 1 year of service. Threshold stress intensity factors (K th ) representing the onset of subcritical crack growth (SCG), were estimated to lie in the range of 0.37-0.44 of K Ic for the lithium-based glass-ceramics and Vitablocs Mark II and between 0.51-0.59 of K Ic for the other materials. Failure distributions associated with mechanistic estimations of strength degradation in-vitro showed to be useful in interpreting failure behavior in-vivo. The parameter K th stood out as a better predictor of clinical performance in detriment to the SCG n

  16. Structural Insight into the Core of CAD, the Multifunctional Protein Leading De Novo Pyrimidine Biosynthesis.

    Science.gov (United States)

    Moreno-Morcillo, María; Grande-García, Araceli; Ruiz-Ramos, Alba; Del Caño-Ochoa, Francisco; Boskovic, Jasminka; Ramón-Maiques, Santiago

    2017-06-06

    CAD, the multifunctional protein initiating and controlling de novo biosynthesis of pyrimidines in animals, self-assembles into ∼1.5 MDa hexamers. The structures of the dihydroorotase (DHO) and aspartate transcarbamoylase (ATC) domains of human CAD have been previously determined, but we lack information on how these domains associate and interact with the rest of CAD forming a multienzymatic unit. Here, we prove that a construct covering human DHO and ATC oligomerizes as a dimer of trimers and that this arrangement is conserved in CAD-like from fungi, which holds an inactive DHO-like domain. The crystal structures of the ATC trimer and DHO-like dimer from the fungus Chaetomium thermophilum confirm the similarity with the human CAD homologs. These results demonstrate that, despite being inactive, the fungal DHO-like domain has a conserved structural function. We propose a model that sets the DHO and ATC complex as the central element in the architecture of CAD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Solving polynomial systems using no-root elimination blending schemes

    KAUST Repository

    Barton, Michael

    2011-01-01

    Searching for the roots of (piecewise) polynomial systems of equations is a crucial problem in computer-aided design (CAD), and an efficient solution is in strong demand. Subdivision solvers are frequently used to achieve this goal; however

  18. Development of virtual private network for JT-60SA CAD integration

    International Nuclear Information System (INIS)

    Oshima, Takayuki; Fujita, Takaaki; Seki, Masami; Kawashima, Hisato; Hoshino, Katsumichi; Shibanuma, Kiyoshi; Verrecchia, M.; Teuchner, B.

    2010-01-01

    The CAD models will be exchanged and integrated at Naka for JT-60SA, a common computer network efficiently connected between Naka site and the Garching site is needed to be established. Virtual Private Network (VPN) was introduced with LAN on computer network physically-separated from JAEA intranet area and firewall. In July 2009, a new VPN connection between the Naka and Garching sites has been successfully demonstrated using IPSec-VPN technology with a commercial and cost-effective firewall/router for security. It was found that the introduction of the Wide Area File Service (WAFS) could solve the issue of the data transmission time and enhance the usability of the VPN for design integration in JT-60SA. (author)

  19. Using AutoCAD to improve the visibility of the organizational technological design

    Directory of Open Access Journals (Sweden)

    Lebedeva Irina Mikhailovna

    2014-01-01

    Full Text Available The article describes the issue of increasing the visibility of technological solutions in organizational-technological design. The ability to visualize the main stages of building process technology contributes to organic integration of all the requirements. A special role for the harmonious perception is played by correct display of the lighting facilities, shadowing. Realistic shadows help to analyze the rooms’ insolation of the designed facility and the surrounding areas. We give a justification for the use of AutoCAD in order to automate the process of visualizing the results of organizational-technological design. The author describes the methods of obtaining realistic natural lighting in AutoCAD without significantly increasing the complexity of the process. Engineering companies in 46 % of cases use the software AutoCAD in order to create construction plans. AutoCAD has a variety of possibilities and is constantly evolving. Continuation is one of the benefits of this program. AutoCAD is unique in terms of customization, because, apart from instruction languages, it has two built-in programming languages: AutoLISP and VisualBasic. Because of these specific features AutoCAD allows to create any applications related to graphics implementation. Constant monitoring of lightning changes allows finding the appropriate in terms of aesthetics, ergonomics and insolation decisions on planning and associating a building or structure to the environment. Solar lighting is simulated by a combination of several directional lightning point sources. The author offers a brief description of the program algorithm, which allows automatically managing lighting settings and creating a file with a realistic visualization of the design solutions.

  20. Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks.

    Science.gov (United States)

    Colombo, Marco; Cavallo, Marco; Miegge, Matteo; Dagna, Alberto; Beltrami, Riccardo; Chiesa, Marco; Poggio, Claudio

    2017-11-01

    The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words: CAD/CAM restorative materials, CIE Lab, Zirconia ceramics.

  1. Design Automation Using Script Languages. High-Level CAD Templates in Non-Parametric Programs

    Science.gov (United States)

    Moreno, R.; Bazán, A. M.

    2017-10-01

    The main purpose of this work is to study the advantages offered by the application of traditional techniques of technical drawing in processes for automation of the design, with non-parametric CAD programs, provided with scripting languages. Given that an example drawing can be solved with traditional step-by-step detailed procedures, is possible to do the same with CAD applications and to generalize it later, incorporating references. In today’s modern CAD applications, there are striking absences of solutions for building engineering: oblique projections (military and cavalier), 3D modelling of complex stairs, roofs, furniture, and so on. The use of geometric references (using variables in script languages) and their incorporation into high-level CAD templates allows the automation of processes. Instead of repeatedly creating similar designs or modifying their data, users should be able to use these templates to generate future variations of the same design. This paper presents the automation process of several complex drawing examples based on CAD script files aided with parametric geometry calculation tools. The proposed method allows us to solve complex geometry designs not currently incorporated in the current CAD applications and to subsequently create other new derivatives without user intervention. Automation in the generation of complex designs not only saves time but also increases the quality of the presentations and reduces the possibility of human errors.

  2. Refining a brief decision aid in stable CAD: cognitive interviews

    OpenAIRE

    Kelly-Blake, Karen; Clark, Stacie; Dontje, Katherine; Olomu, Adesuwa; Henry, Rebecca C; Rovner, David R; Rothert, Marilyn L; Holmes-Rovner, Margaret

    2014-01-01

    Background We describe the results of cognitive interviews to refine the “Making Choices©” Decision Aid (DA) for shared decision-making (SDM) about stress testing in patients with stable coronary artery disease (CAD). Methods We conducted a systematic development process to design a DA consistent with International Patient Decision Aid Standards (IPDAS) focused on Alpha testing criteria. Cognitive interviews were conducted with ten stable CAD patients using the “think aloud” interview techniq...

  3. Fracture and Fatigue Resistance of Cemented versus Fused CAD-on Veneers over Customized Zirconia Implant Abutments.

    Science.gov (United States)

    Nossair, Shereen Ahmed; Aboushelib, Moustafa N; Morsi, Tarek Salah

    2015-01-05

    To evaluate the fracture mechanics of cemented versus fused CAD-on veneers on customized zirconia implant abutments. Forty-five identical customized CAD/CAM zirconia implant abutments (0.5 mm thick) were prepared and seated on short titanium implant abutments (Ti base). A second scan was made to fabricate 45 CAD-on veneers (IPS Empress CAD, A2). Fifteen CAD-on veneers were cemented on the zirconia abutments (Panavia F2.0). Another 15 were fused to the zirconia abutments using low-fusing glass, while manually layered veneers served as control (n = 15). The restorations were subjected to artificial aging (3.2 million cycles between 5 and 10 kg in a water bath at 37°C) before being axially loaded to failure. Fractured specimens were examined using scanning electron microscopy to detect fracture origin, location, and size of critical crack. Stress at failure was calculated using fractography principles (alpha = 0.05). Cemented CAD-on restorations demonstrated significantly higher (F = 72, p CAD-on and manually layered restorations. Fractographic analysis of fractured specimens indicated that cemented CAD-on veneers failed due to radial cracks originating from the veneer/resin interface. Branching of the critical crack was observed in the bulk of the veneer. Fused CAD-on veneers demonstrated cohesive fracture originating at the thickest part of the veneer ceramic, while manually layered veneers failed due to interfacial fracture at the zirconia/veneer interface. Within the limitations of this study, cemented CAD-on veneers on customized zirconia implant abutments demonstrated higher fracture than fused and manually layered veneers. © 2014 by the American College of Prosthodontists.

  4. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  5. Up and running with AutoCAD 2013 2D and 3D drawing and modeling

    CERN Document Server

    Gindis, Elliot

    2012-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains support

  6. Up and running with AutoCAD 2014 2D and 3D drawing and modeling

    CERN Document Server

    Gindis, Elliot

    2013-01-01

    Get ""Up and Running"" with AutoCAD using Gindis's combination of step-by-step instruction, examples, and insightful explanations. The emphasis from the beginning is on core concepts and practical application of AutoCAD in architecture, engineering and design. Equally useful in instructor-led classroom training, self-study, or as a professional reference, the book is written with the user in mind by a long-time AutoCAD professional and instructor based on what works in the industry and the classroom. Strips away complexities, both real and perceived, and reduces AutoCAD t

  7. Detection and function of an intramolecular disulfide bond in the pH-responsive CadC of Escherichia coli

    Directory of Open Access Journals (Sweden)

    Dönhöfer Alexandra

    2011-04-01

    Full Text Available Abstract Background In an acidic and lysine-rich environment Escherichia coli induces expression of the cadBA operon which encodes CadA, the lysine decarboxylase, and CadB, the lysine/cadaverine antiporter. cadBA expression is dependent on CadC, a membrane-integrated transcriptional activator which belongs to the ToxR-like protein family. Activation of CadC requires two stimuli, lysine and low pH. Whereas lysine is detected by an interplay between CadC and the lysine-specific transporter LysP, pH alterations are sensed by CadC directly. Crystal structural analyses revealed a close proximity between two periplasmic cysteines, Cys208 and Cys272. Results Substitution of Cys208 and/or Cys272 by alanine resulted in CadC derivatives that were active in response to only one stimulus, either lysine or pH 5.8. Differential in vivo thiol trapping revealed a disulfide bond between these two residues at pH 7.6, but not at pH 5.8. When Cys208 and Cys272 were replaced by aspartate and lysine, respectively, virtually wild-type behavior was restored indicating that the disulfide bond could be mimicked by a salt bridge. Conclusion A disulfide bond was found in the periplasmic domain of CadC that supports an inactive state of CadC at pH 7.6. At pH 5.8 disulfide bond formation is prevented which transforms CadC into a semi-active state. These results provide new insights into the function of a pH sensor.

  8. Grinding damage assessment for CAD-CAM restorative materials.

    Science.gov (United States)

    Curran, Philippe; Cattani-Lorente, Maria; Anselm Wiskott, H W; Durual, Stéphane; Scherrer, Susanne S

    2017-03-01

    To assess surface/subsurface damage after grinding with diamond discs on five CAD-CAM restorative materials and to estimate potential losses in strength based on crack size measurements of the generated damage. The materials tested were: Lithium disilicate (LIT) glass-ceramic (e.max CAD), leucite glass-ceramic (LEU) (Empress CAD), feldspar ceramic (VM2) (Vita Mark II), feldspar ceramic-resin infiltrated (EN) (Enamic) and a composite reinforced with nano ceramics (LU) (Lava Ultimate). Specimens were cut from CAD-CAM blocs and pair-wise mirror polished for the bonded interface technique. Top surfaces were ground with diamond discs of respectively 75, 54 and 18μm. Chip damage was measured on the bonded interface using SEM. Fracture mechanics relationships were used to estimate fracture stresses based on average and maximum chip depths assuming these to represent strength limiting flaws subjected to tension and to calculate potential losses in strength compared to manufacturer's data. Grinding with a 75μm diamond disc induced on a bonded interface critical chips averaging 100μm with a potential strength loss estimated between 33% and 54% for all three glass-ceramics (LIT, LEU, VM2). The softer materials EN and LU were little damage susceptible with chips averaging respectively 26μm and 17μm with no loss in strength. Grinding with 18μm diamond discs was still quite detrimental for LIT with average chip sizes of 43μm and a potential strength loss of 42%. It is essential to understand that when grinding glass-ceramics or feldspar ceramics with diamond discs surface and subsurface damage are induced which have the potential of lowering the strength of the ceramic. Careful polishing steps should be carried out after grinding especially when dealing with glass-ceramics. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. The effect of milling and postmilling procedures on the surface roughness of CAD/CAM materials.

    Science.gov (United States)

    Mota, Eduardo Gonçalves; Smidt, Laura Nunes; Fracasso, Lisiane Martins; Burnett, Luiz Henrique; Spohr, Ana Maria

    2017-11-12

    The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures. Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL. Ten flat samples of each material were obtained. The surface roughness (Ra) test was performed before and after milling, crystallization, polishing, and glaze when indicated, followed by SEM and AFM analysis. Data were submitted to one-way ANOVA with repeated measures and the Tukey HSD test (α = 0.05). The milling step significantly increased the roughness of all the tested materials (P CAD and Suprinity) were more suitable to roughness than the other tested materials (P CAD/CAM materials, that is, fully sintered, should be only hand polished. The glaze step can be suppressed resulting in time saving. However, the glaze step in soft-milling lithium disilicate is imperative. © 2017 Wiley Periodicals, Inc.

  10. The use of high fidelity CAD models as the basis for training on complex systems

    Science.gov (United States)

    Miller, Kellie; Tanner, Steve

    1993-01-01

    During the design phases of large and complex systems such as NASA's Space Station Freedom (SSF), there are few, if any physical prototypes built. This is often due to their expense and the realization that the design is likely to change. This poses a problem for training, maintainability, and operations groups who are tasked to lay the foundation of plans for using these systems. The Virtual Reality and Visualization Laboratory at the Boeing Advanced Computing Group's Huntsville facility is supporting the use of high fidelity, detailed design models that are generated during the initial design phases, for use in training, maintainability and operations exercises. This capability was used in its non-immersive form to great effect at the SSF Critical Design Review (CDR) during February, 1993. Allowing the user to move about within a CAD design supports many efforts, including training and scenario study. We will demonstrate via a video of the Maintainability SSF CDR how this type of approach can be used and why it is so effective in conveying large amounts of information quickly and concisely. We will also demonstrate why high fidelity models are so important for this type of training system and how it's immersive aspects may be exploited as well.

  11. Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo

    2017-08-15

    Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Inundation Analysis of Reservoir Flood Based on Computer Aided Design (CAD and Digital Elevation Model (DEM

    Directory of Open Access Journals (Sweden)

    Jiqing Li

    2018-04-01

    Full Text Available GIS (Geographic Information System can be used to combine multiple hydrologic data and geographic data for FIA (Flood Impact Assessment. For a developing country like China, a lot of geographic data is in the CAD (Computer Aided Design format. The commonly used method for converting CAD into DEM may result in data loss. This paper introduces a solution for the conversion between CAD data and DEM data. The method has been applied to the FIA based on the topographic map of CAD in Hanjiang River. When compared with the other method, the new method solves the data loss problem. Besides, the paper use GIS to simulate the inundation range, area, and the depth distribution of flood backwater. Based on the analysis, the author concludes: (1 the differences of the inundation areas between the flood of HQ100 and the flood of HQ50 are small. (2 The inundation depth shows a decreasing trend along the upstream of the river. (3 The inundation area less than 4 m in flood of HQ50 is larger than that in flood of HQ100, the result is opposite when the inundation depth is greater than 4 m. (4 The flood loss is 392.32 million RMB for flood of HQ50 and 610.02 million RMB for flood of HQ100. The method can be applied to FIA.

  13. Rule-Based Design of Plant Expression Vectors Using GenoCAD.

    Science.gov (United States)

    Coll, Anna; Wilson, Mandy L; Gruden, Kristina; Peccoud, Jean

    2015-01-01

    Plant synthetic biology requires software tools to assist on the design of complex multi-genic expression plasmids. Here a vector design strategy to express genes in plants is formalized and implemented as a grammar in GenoCAD, a Computer-Aided Design software for synthetic biology. It includes a library of plant biological parts organized in structural categories and a set of rules describing how to assemble these parts into large constructs. Rules developed here are organized and divided into three main subsections according to the aim of the final construct: protein localization studies, promoter analysis and protein-protein interaction experiments. The GenoCAD plant grammar guides the user through the design while allowing users to customize vectors according to their needs. Therefore the plant grammar implemented in GenoCAD will help plant biologists take advantage of methods from synthetic biology to design expression vectors supporting their research projects.

  14. A tool to convert CAD models for importation into Geant4

    Science.gov (United States)

    Vuosalo, C.; Carlsmith, D.; Dasu, S.; Palladino, K.; LUX-ZEPLIN Collaboration

    2017-10-01

    The engineering design of a particle detector is usually performed in a Computer Aided Design (CAD) program, and simulation of the detector’s performance can be done with a Geant4-based program. However, transferring the detector design from the CAD program to Geant4 can be laborious and error-prone. SW2GDML is a tool that reads a design in the popular SOLIDWORKS CAD program and outputs Geometry Description Markup Language (GDML), used by Geant4 for importing and exporting detector geometries. Other methods for outputting CAD designs are available, such as the STEP format, and tools exist to convert these formats into GDML. However, these conversion methods produce very large and unwieldy designs composed of tessellated solids that can reduce Geant4 performance. In contrast, SW2GDML produces compact, human-readable GDML that employs standard geometric shapes rather than tessellated solids. This paper will describe the development and current capabilities of SW2GDML and plans for its enhancement. The aim of this tool is to automate importation of detector engineering models into Geant4-based simulation programs to support rapid, iterative cycles of detector design, simulation, and optimization.

  15. Effect of Crystallization Firing on Marginal Gap of CAD/CAM Fabricated Lithium Disilicate Crowns.

    Science.gov (United States)

    Gold, Steven A; Ferracane, Jack L; da Costa, Juliana

    2018-01-01

    To evaluate the marginal gaps of CAD/CAM (CEREC 3) produced crowns made from leucite-reinforced glass-ceramic (IPS Empress CAD) blocks (LG), and lithium-disilicate (IPS e.max CAD) blocks before (LD-B), and after (LD-A) crystallization firing. A human molar tooth (#19) was mounted with adjacent teeth on a typodont and prepared for a full-coverage ceramic crown. The typodont was assembled in the mannequin head to simulate clinical conditions. After tooth preparation 15 individual optical impressions were taken by the same operator using titanium dioxide powder and a CEREC 3 camera per manufacturer's instructions. One operator designed and machined the crowns in leucite-reinforced glass-ceramic blocks (n = 5) and lithium-disilicate blocks (n = 10) using the CEREC 3 system. The crowns were rigidly seated on the prepared tooth, and marginal gaps (μm) were measured with an optical microscope (500×) at 12 points, 3 on each of the M, B, D, and L surfaces of the leucite-reinforced glass-ceramic crowns and the lithium-disilicate crowns before and after crystallization firing. Results were analyzed by two-way ANOVA followed by a Tukey's post hoc multiple comparison test (α = 0.05). The overall mean marginal gaps (μm) for the crowns evaluated were: LG = 49.2 ± 5.5, LD-B = 42.9 ± 12.2, and LD-A = 57.2 ± 16.0. The marginal gaps for LG and LD-B were not significantly different, but both were significantly less than for LD-A. The type of ceramic material did not affect the marginal gap of CAD/CAM crowns. The crystallization firing process required for lithium-disilicate crowns resulted in a significant increase in marginal gap size, likely due to shrinkage of the ceramic during the crystallization process. The marginal gap of CAD/CAM-fabricated lithium disilicate crowns increases following crystallization firing. The marginal gap still remains within clinically acceptable parameters. © 2017 by the American College of Prosthodontists.

  16. Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

    International Nuclear Information System (INIS)

    Giger, Maryellen L.; Chan, Heang-Ping; Boone, John

    2008-01-01

    The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the

  17. Up and Running with AutoCAD 2011 2D and 3D Drawing and Modeling

    CERN Document Server

    Gindis, Elliot

    2010-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains supporting graphics (screen shot

  18. Up and Running with AutoCAD 2012 2D and 3D Drawing and Modeling

    CERN Document Server

    Gindis, Elliot

    2011-01-01

    Gindis introduces AutoCAD with step by step instructions, stripping away complexities to  begin working in AutoCAD immediately.  All concepts are explained first in theory, and then shown in practice, helping the reader understand what it is they are doing and why, before they do it. Divided into three parts, the book covers beginning through advanced AutoCAD, including 3D features.  Also included is an extensive Appendix for each part, detailing additional useful CAD-related information not often found in other text books The book contains supporting graphics (screen shot

  19. Functional characterization of a cadmium resistance operon in Staphylococcus aureus ATCC12600: CadC does not function as a repressor.

    Science.gov (United States)

    Hoogewerf, Arlene J; Dyk, Lisa A Van; Buit, Tyler S; Roukema, David; Resseguie, Emily; Plaisier, Christina; Le, Nga; Heeringa, Lee; Griend, Douglas A Vander

    2015-02-01

    Sequencing of a cadmium resistance operon from a Staphylococcus aureus ATCC12600 plasmid revealed that it is identical to a cadCA operon found in MRSA strains. Compared to plasmid-cured and cadC-mutant strains, cadC-positive ATCC12600 cells had increased resistance to cadmium (1 mg ml(-1) cadmium sulfate) and zinc (4 mg ml(-1) zinc sulfate), but not to other metal ions. After growth in media containing 20 µg ml(-1) cadmium sulfate, cadC-mutant cells contained more intracellular cadmium than cadC-positive ATCC12600 cells, suggesting that cadC absence results in impaired cadmium efflux. Electrophoretic mobility shift assays were performed with CadC proteins encoded by the S. aureus ATCC12600 plasmid and by the cadC gene of pI258, which is known to act as a transcriptional repressor and shares only 47% protein sequence identity with ATCC12600 CadC. Mobility shifts occurred when pI258 CadC protein was incubated with the promoter DNA-regions from the pI258 and S. aureus ATCC12600 cadCA operons, but did not occur with S. aureus ATCC12600 CadC protein, indicating that the ATCC12600 CadC protein does not interact with promoter region DNA. This cadCA operon, found in MRSA strains and previously functionally uncharacterized, increases resistance to cadmium and zinc by an efflux mechanism, and CadC does not function as a transcriptional repressor. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    Directory of Open Access Journals (Sweden)

    Yu-Tzu Wang

    2017-01-01

    Full Text Available This study integrates cone-beam computed tomography (CBCT/laser scan image superposition, computer-aided design (CAD, and 3D printing (3DP to develop a technology for producing customized dental (orthodontic miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews.

  1. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing.

    Science.gov (United States)

    Wang, Yu-Tzu; Yu, Jian-Hong; Lo, Lun-Jou; Hsu, Pin-Hsin; Lin, CHun-Li

    2017-01-01

    This study integrates cone-beam computed tomography (CBCT)/laser scan image superposition, computer-aided design (CAD), and 3D printing (3DP) to develop a technology for producing customized dental (orthodontic) miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews.

  2. Energy-aware memory management for embedded multimedia systems a computer-aided design approach

    CERN Document Server

    Balasa, Florin

    2011-01-01

    Energy-Aware Memory Management for Embedded Multimedia Systems: A Computer-Aided Design Approach presents recent computer-aided design (CAD) ideas that address memory management tasks, particularly the optimization of energy consumption in the memory subsystem. It explains how to efficiently implement CAD solutions, including theoretical methods and novel algorithms. The book covers various energy-aware design techniques, including data-dependence analysis techniques, memory size estimation methods, extensions of mapping approaches, and memory banking approaches. It shows how these techniques

  3. Analysis on the workspace of palletizing robot based on AutoCAD

    Science.gov (United States)

    Li, Jin-quan; Zhang, Rui; Guan, Qi; Cui, Fang; Chen, Kuan

    2017-10-01

    In this paper, a four-degree-of-freedom articulated palletizing robot is used as the object of research. Based on the analysis of the overall configuration of the robot, the kinematic mathematical model is established by D-H method to figure out the workspace of the robot. In order to meet the needs of design and analysis, using AutoCAD secondary development technology and AutoLisp language to develop AutoCAD-based 2D and 3D workspace simulation interface program of palletizing robot. At last, using AutoCAD plugin, the influence of structural parameters on the shape and position of the working space is analyzed when the structure parameters of the robot are changed separately. This study laid the foundation for the design, control and planning of palletizing robots.

  4. [Clinical skills and outcomes of chair-side computer aided design and computer aided manufacture system].

    Science.gov (United States)

    Yu, Q

    2018-04-09

    Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.

  5. Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.

    Science.gov (United States)

    Buhmann, Sonja; Herzog, Peter; Liang, Jin; Wolf, Mathias; Salganicoff, Marcos; Kirchhoff, Chlodwig; Reiser, Maximilian; Becker, Christoph H

    2007-06-01

    To evaluate the performance of a prototype computer-aided diagnosis (CAD) tool using artificial intelligence techniques for the detection of pulmonary embolism (PE) and the possible benefit for general radiologists. Forty multidetector row computed tomography datasets (16/64- channel scanner) using 100 kVp, 100 mAs effective/slice, and 1-mm axial reformats in a low-frequency reconstruction kernel were evaluated. A total of 80 mL iodinated contrast material was injected at a flow rate of 5 mL/seconds. Primarily, six general radiologists marked any PE using a commercially available lung evaluation software with simultaneous, automatic processing by CAD in the background. An expert panel consisting of two chest radiologists analyzed all PE marks from the readers and CAD, also searching for additional finding primarily missed by both, forming the ground truth. The ground truth consisted of 212 emboli. Of these, 65 (31%) were centrally and 147 (69%) were peripherally located. The readers detected 157/212 emboli (74%) leading to a sensitivity of 97% (63/65) for central and 70% (103/147) for peripheral emboli with 9 false-positive findings. CAD detected 168/212 emboli (79%), reaching a sensitivity of 74% for central (48/65) and 82%(120/147) for peripheral emboli. A total of 154 CAD candidates were considered as false positives, yielding an average of 3.85 false positives/case. The CAD software showed a sensitivity comparable to that of the general radiologists, but with more false positives. CAD detection of findings incremental to the radiologists suggests benefit when used as a second reader. Future versions of CAD have the potential to further increase clinical benefit by improving sensitivity and reducing false marks.

  6. Microleakage of composite crowns luted on CAD/CAM-milled human molars: a new method for standardized in vitro tests.

    Science.gov (United States)

    Schlenz, Maximiliane Amelie; Schmidt, Alexander; Rehmann, Peter; Niem, Thomas; Wöstmann, Bernd

    2018-04-24

    To investigate debonding of full crowns made of CAD/CAM composites, CAD/CAM technology was applied to manufacture standardized test abutments to increase the reproducibility of human teeth used in in vitro studies. A virtual test abutment and the corresponding virtual crown were designed and two STL data sets were generated. Sixty-four human third molars and CAD/CAM blocks were milled using a CNC machine. Crowns of four different composite blocks (Lava Ultimate (LU), Brilliant Crios (BC), Cerasmart (CS), Experimental (EX)) were adhesively bonded with their corresponding luting system (LU: Scotchbond Universal/RelyX Ultimate; BC: One Coat 7 Universal/DuoCem; CS: G-PremioBond/G-Cem LinkForce; EX: Experimental-Bond/Experimental-Luting-Cement). Half of the specimens were chemical-cured (CC) and the others were light-cured (LC). Afterwards, specimens were artificially aged in a chewing simulator (WL-tec, 1 million cycles, 50-500 N, 2 Hz, 37 °C). Finally, a dye penetration test was used to detect debonding. For inspection, the specimens were sliced, and penetration depth was measured with a digital microscope. Data were analyzed with the Mann-Whitney U test. No cases of total debonding were observed after cyclic loading. However, the LC specimens showed a significantly lower amount of leakage than the CC ones (p CAD/CAM technology in highly standardized test abutments for in vitro testing. For CAD/CAM composites, light curing should be performed. The success of a restoration depends on the long-term sealing ability of the luting materials, which avoids debonding along with microleakage. For CAD/CAM composites, separate light curing of the adhesive and luting composite is highly recommended.

  7. The application of CAD, CAE & CAM in development of butterfly valve’s disc

    Science.gov (United States)

    Asiff Razif Shah Ranjit, Muhammad; Hanie Abdullah, Nazlin

    2017-06-01

    The improved design of a butterfly valve disc is based on the concept of sandwich theory. Butterfly valves are mostly used in various industries such as oil and gas plant. The primary failure modes for valves are indented disc, keyways and shaft failure and the cavitation damage. Emphasis on the application of CAD, a new model of the butterfly valve’s disc structure was designed. The structure analysis was analysed using the finite element analysis. Butterfly valve performance factors can be obtained is by using Computational Fluid Dynamics (CFD) software to simulate the physics of fluid flow in a piping system around a butterfly valve. A comparison analysis was done using the finite element to justify the performance of the structure. The second application of CAE is the computational fluid flow analysis. The upstream pressure and the downstream pressure was analysed to calculate the cavitation index and determine the performance throughout each opening position of the valve. The CAM process was done using 3D printer to produce a prototype and analysed the structure in form of prototype. The structure was downscale fabricated based on the model designed initially through the application of CAD. This study is utilized the application of CAD, CAE and CAM for a better improvement of the butterfly valve’s disc components.

  8. Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography

    International Nuclear Information System (INIS)

    Ciatto, Stefano; Del Turco, Marco Rosselli; Risso, Gabriella; Catarzi, Sandra; Bonardi, Rita; Viterbo, Valeria; Gnutti, Pierangela; Guglielmoni, Barbara; Pinelli, Lelio; Pandiscia, Anna; Navarra, Francesco; Lauria, Adele; Palmiero, Rosa; Indovina, Pietro Luigi

    2003-01-01

    Objective: To evaluate the role of computer aided detection (CAD) in improving the interpretation of screening mammograms Material and methods: Ten radiologists underwent a proficiency test of screening mammography first by conventional reading and then with the help of CAD. Radiologists were blinded to test results for the whole study duration. Results of conventional and CAD reading were compared in terms of sensitivity and recall rate. Double reading was simulated combining conventional readings of four expert radiologists and compared with CAD reading. Results: Considering all ten readings, cancer was identified in 146 or 153 of 170 cases (85.8 vs. 90.0%; χ 2 =0.99, df=1, P=0.31) and recalls were 106 or 152 of 1330 cases (7.9 vs. 11.4%; χ 2 =8.69, df=1, P=0.003) at conventional or CAD reading, respectively. CAD reading was essentially the same (sensitivity 97.0 vs. 96.0%; χ 2 =7.1, df=1, P=0.93; recall rate 10.7 vs. 10.6%; χ 2 =1.5, df=1, P=0.96) as compared with simulated conventional double reading. Conclusion: CAD reading seems to improve the sensitivity of conventional reading while reducing specificity, both effects being of limited size. CAD reading had almost the same performance of simulated conventional double reading, suggesting a possible use of CAD which needs to be confirmed by further studies inclusive of cost-effective analysis

  9. Kinematic optimization of upgrade to the Hobby-Eberly Telescope through novel use of commercially available three-dimensional CAD package

    Science.gov (United States)

    Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.

    2010-07-01

    The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.

  10. Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks

    Science.gov (United States)

    Colombo, Marco; Cavallo, Marco; Miegge, Matteo; Dagna, Alberto; Beltrami, Riccardo; Chiesa, Marco

    2017-01-01

    Background The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). Material and Methods All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. Results One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. Conclusions The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words:CAD/CAM restorative materials, CIE Lab, Zirconia ceramics. PMID:29302281

  11. The application of springback compensation to the CAD geometries of forming tools: Milestone 2

    NARCIS (Netherlands)

    Lingbeek, R.A.

    2005-01-01

    For car body parts, generally a surface modeling CAD system is used. The geometry of the tools that are used for forming the parts is based directly on this description. To compensate for springback after forming, the tools have to be modified. This turns out to be a complicated and time consuming

  12. Roughness, surface energy, and superficial damages of CAD/CAM materials after surface treatment.

    Science.gov (United States)

    Strasser, Thomas; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-02-05

    The aim of this study was to examine the effects of surface pre-treatment on CAD/CAM materials including ceramics, zirconia, resin-infiltrated ceramic, and resin-based composite. Specimens were made of ten CAD/CAM materials (Celtra Duo, Degudent, D; Vita Suprinity, Vita, D; E.max CAD, Ivoclar-Vivadent, FL; E.max ZirCAD, Ivoclar-Vivadent, FL; Vita Enamic, Vita, D; Cerasmart, GC, B; LAVA Ultimate, 3M, D; SHOFU Block HC, SHOFU, US; Grandio Blocs, VOCO, D; BRILLIANT Crios, Coltene, CH) and pretreated to represent clinical procedures (Hf 20 s/5%; phosphoric acid 20 s/37%; Monobond etch and prime (Ivoclar-Vivadent, FL); water-cooled diamond bur (80 μm; 4 μm); Al 2 O 3 -blasting (50 μm/1 bar, 50 μm/2 bar, 120 μm/1 bar, 120 μm/2 bar); untreated; manufacturer's instructions). SEM-analysis (Phenom, FEI, NL) of the surfaces was performed (magnifications ≤ 10,000×). Roughness values R a , R z (KJ 3D, Keyence, J), and surface energy SE (OCA15 plus, SCA20, DataPhysics, D) were determined (statistics: non-parametric Mann-Whitney U test/Kruskal-Wallis test for independent specimen, α = 0.05). Kruskal-Wallis revealed significant (p CAD/CAM materials require individual pre-treatment for optimized and protective surface activation. Cementation is a key factor for clinical success. Given the variety of available CAD/CAM materials, specific procedures are needed.

  13. Variation in CAD Secondary Prevention Prescription among Outpatient Cardiology Practices: Insights from the NCDR®

    Science.gov (United States)

    Maddox, Thomas M.; Chan, Paul S.; Spertus, John A.; Tang, Fengming; Jones, Phil; Ho, P. Michael; Bradley, Steven M.; Tsai, Thomas T.; Bhatt, Deepak L.; Peterson, Pamela N.

    2014-01-01

    Objectives This study assesses practice variation of secondary prevention medication prescription among coronary artery disease (CAD) patients treated in outpatient practices participating in the NCDR® PINNACLE Registry®. Background Among patients with CAD, secondary prevention with a combination of beta-blockers, angiotensin converting enzyme inhibitors/angiotensin receptor blockers, and statins reduces cardiac mortality and myocardial infarction (MI). Accordingly, every CAD patient should receive the combination of these medications for which they are eligible. However, little is known about current prescription patterns of these medications and the variation in use among outpatient cardiology clinics. Methods Using data from NCDR® PINNACLE Registry®, a national outpatient cardiology practice registry, we assessed medication prescription patterns among eligible CAD patients between July 2008 and December 2010. Overall rates of prescription and variation by practice were calculated, adjusting for patient characteristics. Results Among 156,145 CAD patients in 58 practices, 103,830 (66.5%) were prescribed the optimal combination of medications for which they were eligible. The median rate of optimal combined prescription by practice was 73.5% and varied from 28.8% to 100%. After adjustment for patient factors, the practice median rate ratio for prescription was 1.25 (95% CI 1.2,1.32), indicating a 25% likelihood that 2 random practices would differ in treating identical CAD patients. Conclusions Among a national registry of CAD patients treated in outpatient cardiology practices, over one-third of patients failed to receive their optimal combination of secondary prevention medications. Significant variation was observed across practices, even after adjusting for patient characteristics, suggesting that quality improvement efforts may be needed to support more uniform practice. PMID:24184238

  14. Assessment of reliability of CAD-CAM tooth-colored implant custom abutments.

    Science.gov (United States)

    Guilherme, Nuno Marques; Chung, Kwok-Hung; Flinn, Brian D; Zheng, Cheng; Raigrodski, Ariel J

    2016-08-01

    Information is lacking about the fatigue resistance of computer-aided design and computer-aided manufacturing (CAD-CAM) tooth-colored implant custom abutment materials. The purpose of this in vitro study was to investigate the reliability of different types of CAD-CAM tooth-colored implant custom abutments. Zirconia (Lava Plus), lithium disilicate (IPS e.max CAD), and resin-based composite (Lava Ultimate) abutments were fabricated using CAD-CAM technology and bonded to machined titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy inserts for conical connection implants (NobelReplace Conical Connection RP 4.3×10 mm; Nobel Biocare). Three groups (n=19) were assessed: group ZR, CAD-CAM zirconia/Ti-6Al-4V bonded abutments; group RC, CAD-CAM resin-based composite/Ti-6Al-4V bonded abutments; and group LD, CAD-CAM lithium disilicate/Ti-6Al-4V bonded abutments. Fifty-seven implant abutments were secured to implants and embedded in autopolymerizing acrylic resin according to ISO standard 14801. Static failure load (n=5) and fatigue failure load (n=14) were tested. Weibull cumulative damage analysis was used to calculate step-stress reliability at 150-N and 200-N loads with 2-sided 90% confidence limits. Representative fractured specimens were examined using stereomicroscopy and scanning electron microscopy to observe fracture patterns. Weibull plots revealed β values of 2.59 for group ZR, 0.30 for group RC, and 0.58 for group LD, indicating a wear-out or cumulative fatigue pattern for group ZR and load as the failure accelerating factor for groups RC and LD. Fractographic observation disclosed that failures initiated in the interproximal area where the lingual tensile stresses meet the compressive facial stresses for the early failure specimens. Plastic deformation of titanium inserts with fracture was observed for zirconia abutments in fatigue resistance testing. Significantly higher reliability was found in group ZR, and no significant differences in reliability were

  15. Shutdown dose rate analysis with CAD geometry, Cartesian/tetrahedral mesh, and advanced variance reduction

    International Nuclear Information System (INIS)

    Biondo, Elliott D.; Davis, Andrew; Wilson, Paul P.H.

    2016-01-01

    Highlights: • A CAD-based shutdown dose rate analysis workflow has been implemented. • Cartesian and superimposed tetrahedral mesh are fully supported. • Biased and unbiased photon source sampling options are available. • Hybrid Monte Carlo/deterministic techniques accelerate photon transport. • The workflow has been validated with the FNG-ITER benchmark problem. - Abstract: In fusion energy systems (FES) high-energy neutrons born from burning plasma activate system components to form radionuclides. The biological dose rate that results from photons emitted by these radionuclides after shutdown—the shutdown dose rate (SDR)—must be quantified for maintenance planning. This can be done using the Rigorous Two-Step (R2S) method, which involves separate neutron and photon transport calculations, coupled by a nuclear inventory analysis code. The geometric complexity and highly attenuating configuration of FES motivates the use of CAD geometry and advanced variance reduction for this analysis. An R2S workflow has been created with the new capability of performing SDR analysis directly from CAD geometry with Cartesian or tetrahedral meshes and with biased photon source sampling, enabling the use of the Consistent Adjoint Driven Importance Sampling (CADIS) variance reduction technique. This workflow has been validated with the Frascati Neutron Generator (FNG)-ITER SDR benchmark using both Cartesian and tetrahedral meshes and both unbiased and biased photon source sampling. All results are within 20.4% of experimental values, which constitutes satisfactory agreement. Photon transport using CADIS is demonstrated to yield speedups as high as 8.5·10"5 for problems using the FNG geometry.

  16. The Association between Androgenic Hormone Levels and the Risk of Developing Coronary Artery Disease (CAD).

    Science.gov (United States)

    Allameh, Farzad; Pourmand, Gholamreza; Bozorgi, Ali; Nekuie, Sepideh; Namdari, Farshad

    2016-01-01

    The aim of the study was to evaluate the relationship between the serum levels of androgens and Coronary Artery Disease (CAD) in an Iranian population. Male individuals admitted to Tehran Heart Center and Sina Hospital, Tehran, Iran from 2011-2012 were categorized into CAD and control groups based on selective coronary angiography. Baseline demographic data, including age, BMI, diabetes, and a history of hypertension were recorded. Patients were also assessed for their serum levels of total testosterone, free testosterone, estradiol, dehydroepi and rosterone sulfate (DHEA-S), and Sex Hormone Binding Globulin (SHBG). Data analysis was carried out chi-square and ANOVA tests as well as logistic regression analysis. Two hundred patients were in the CAD group and 135 individuals in control group. In the CAD group, 69 had single-vessel disease, 49 had two-vessel diseases, and 82 had three-vessel diseases. Statistically significant differences were observed between the individuals in the two groups with respect to age (PCAD group; however, the serum level of SHBG was higher in the CAD group than in the control group (P=0.007). Results of the logistic regression analysis indicated that only age (P=0.042) and diabetes (P=0.003) had significant relationships with CAD. Although the serum levels of some of the androgens were significantly different between the two groups, no association was found between androgenic hormone levels and the risk of CAD, due mainly to the effect of age and diabetes.

  17. Evaluation of diagnostic efficiency of intelligence program for automatic diagnosis of circumferential profiles of myocardial short axial SPECT

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Tada, Akira; Nakajima, Kenichi; Taki, Junichi; Kojima, Kazuhiko.

    1984-01-01

    Quantitative diagnosis using circumferential profile (CFP) is widely employed for Tl-201 myocardial imaging. However, its diagnostic efficiency is susceptible to the number and composition of the confirmed normal (CN) group. Intelligence program for CFP data file and automatic diagnosis (CAD), which was previously developed by us, was modified for creating universal data file (d-base) and evaluated its diagnostic efficiency for myocardial short axial images according to the number of CNs. CAD consists of following 3 major functions: (1) CFP data filing to d-base, (2) modification and correction of file data, and (3) automatic diagnosis of CFP. When function (1) or (2) is completed, new diagnostic criteria (mean-2 sd) are generated automatically using CN data in the d-base at that time. Because of this function, diagnostic criteria are changeable according to the number of CNs. Sensitivity (TP) and specificity (TN) of CAD program for Tl-201 7-pinhole images of 16 normals and 17 ischemic heart diseases (IHDs) were 100%, 44% (CN = 4), 88%, 94% (CN = 8 or 16) and 88%, 100% (CN = 12), respectively. Diagnostic efficiency reached plateau in more than 8 CNs. Although number of patients were limited (8 CNs and 6 IHDs), results of CAD for short axial SPECT showed consistent tendency with 7-pinhole images. In conclusion, intelligence program is necessary for automatic diagnosis using quantitative criteria under the clinical condition of daily increasing informations. Automatic diagnosis of CFP using CAD program is simple, effective and useful for interpretation of Tl-201 myocardial short axial images. CAD program is applicable to any quantitative distribution study using CFPs. (author)

  18. Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

    Directory of Open Access Journals (Sweden)

    Suk-Ho Kang

    2013-08-01

    Full Text Available Objectives There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent and Rosetta SM (Hass, and to observe their crystalline structures. Materials and Methods Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi and x-ray diffraction (XRD, Rigaku analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05. The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.

  19. Accuracy of CAD-CAM-fabricated removable partial dentures.

    Science.gov (United States)

    Arnold, Christin; Hey, Jeremias; Schweyen, Ramona; Setz, Jürgen M

    2018-04-01

    The conventional fabrication of removable partial dentures (RPDs) is a complex, error-prone, time-consuming, and expensive process. The use of computer-aided design and computer-aided manufacturing (CAD-CAM) techniques, especially rapid prototyping, promises a more effective method for fabricating RPD frameworks. The purpose of this in vitro study was to evaluate the fit of RPD clasps fabricated by means of 4 different CAD-CAM-systems and to compare those fittings with that of the conventional lost-wax casting technique (LWT). A master model of a partially edentulous maxilla with the canines and second molars as the remaining teeth was fabricated. After the model was optically scanned, we designed a quadrangularly supported RPD with 4 clasps and a palatal strap major connector. A standard tessellation language data set was used to fabricate 12 identical RPDs by using 4 different CAD-CAM techniques: indirect rapid prototyping (wax inject printing combined with LWT), direct rapid prototyping (selective laser melting), indirect milling (wax milling with LWT), and direct milling (resin milling [polyetheretherketone]). Three conventionally cast RPDs (LWT) served as the control group. The fit accuracy of the clasps (n=12 for each group) was determined in both the horizontal and vertical dimensions by using light microscopy. Indirectly milled RPDs (117 ±34 μm horizontal and 45 ±21 μm vertical) and directly milled RPDs (43 ±23 μm horizontal, and 38 ±21 μm vertical) showed significantly better (P<.05) fit than did conventionally fabricated LWT RPDs (133 ±59 μm horizontal; 73 ±25 μm vertical). The worst fit was found for RPDs fabricated using indirect rapid prototyping (323 ±188 μm horizontal and 112 ±60 μm vertical) or direct rapid prototyping (365 ±205 μm horizontal and 363 ±133 μm vertical), which were unstable on the master model, making them unsuitable for clinical use. Most RPDs exhibited smaller vertical measuring distances. Compared with the LWT

  20. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  1. CAD-RADS(TM) Coronary Artery Disease - Reporting and Data System. An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Radiology (ACR) and the North American Society for Cardiovascular Imaging (NASCI). Endorsed by the American College of Cardiology.

    Science.gov (United States)

    Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A

    2016-01-01

    The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  2. Diseño óptimo multiobjetivo y planificación del proceso de fabricación (CAD/CAPP de redes de conductos de climatización // Optimal design and planning of the manufacturing process (CAD / CAPP of air conditioning pipeline nets

    Directory of Open Access Journals (Sweden)

    A. Cordovés García

    1999-01-01

    Full Text Available La integración de las tareas de diseño y preparación de la producción del producto constituye una de las principales direccionesde trabajo de diversos centros de investigación tecnológica. La tendencia en este sentido es la utilización eficiente de lainformación asociada al diseño, en las etapas subsiguientes de creación del producto.El sistema que se presenta efectúa el diseño óptimo automatizado de las redes de conductos para la climatización de locales apartir de la evaluación de los criterios fundamentales que determinan la eficiencia de la instalación; entre los que se destacan: elcosto de producción, las pérdidas de carga y el nivel de ruido del conducto.Durante la creación del diseño se pueden conocer los valores de los parámetros del fluido en cualquier punto de la red, asícomo obtener un listado clasificado de los componentes utilizados y del material necesario. La información geométrica ydimensional sobre los elementos de la red así como su necesidad, es transferida automáticamente desde la sección CAD a la depreparación de la producción, sección CAPP, la que se utiliza para organizar el corte definitivo del material, por métodosconvencionales o con tecnología CNC de acuerdo a las posibilidades tecnológicas del usuario.Palabras claves: Di seño ópt imo, CAD, cl imat ización.____________________________________________________________________AbstractOne of the main work directions of several technological research institutions is the integration of the product design andpreparation of the manufacturing tasks. The trend in this sense is to make an efficient use of the information associated to thedesign, in the subsequent stages of the production process.The system we now introduce is able to carry out the optimum automated design of the pipelines used for room airconditioning, through the analysis and evaluation of the main criteria that determine the efficiency of the installation. Amongthese are the

  3. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    Science.gov (United States)

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial

  4. An integrated 3D design, modeling and analysis resource for SSC detector systems

    International Nuclear Information System (INIS)

    DiGiacomo, N.J.; Adams, T.; Anderson, M.K.; Davis, M.; Easom, B.; Gliozzi, J.; Hale, W.M.; Hupp, J.; Killian, K.; Krohn, M.; Leitch, R.; Lajczok, M.; Mason, L.; Mitchell, J.; Pohlen, J.; Wright, T.

    1989-01-01

    Integrated computer aided engineering and design (CAE/CAD) is having a significant impact on the way design, modeling and analysis is performed, from system concept exploration and definition through final design and integration. Experience with integrated CAE/CAD in high technology projects of scale and scope similar to SSC detectors leads them to propose an integrated computer-based design, modeling and analysis resource aimed specifically at SSC detector system development. The resource architecture emphasizes value-added contact with data and efficient design, modeling and analysis of components, sub-systems or systems with fidelity appropriate to the task. They begin with a general examination of the design, modeling and analysis cycle in high technology projects, emphasizing the transition from the classical islands of automation to the integrated CAE/CAD-based approach. They follow this with a discussion of lessons learned from various attempts to design and implement integrated CAE/CAD systems in scientific and engineering organizations. They then consider the requirements for design, modeling and analysis during SSC detector development, and describe an appropriate resource architecture. They close with a report on the status of the resource and present some results that are indicative of its performance. 10 refs., 7 figs

  5. METABOLIC AND AUTOIMMUNE RISK FACTORS FOR CORONARY ARTERY DISEASE (CAD IN HEART TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    T. A. Khalilulin

    2010-01-01

    Full Text Available One of the most essential autoimmunity risk factors for development of CAD are increasing level of anticardiolipin antibodies and homocystein. This report presents retrospective analyses of 39 heart transplant recipients with maximal follow up over 16 years. Our results showed that hyperhomocystenemia and high levels of anticardiolipin antibodies play great value in development of CAD. Thus relative risks for development of CAD in presence both high levels of anticardiolipin antibodies and homocysteine are higher, than in traditional nonimmune risk factors. 

  6. SpiCAD: Integrated environment for circuitry simulation with SPICE code

    Energy Technology Data Exchange (ETDEWEB)

    D' Amore, D; Padovini, G; Santomauro, M [Politecnico di Milano (Italy). Dip. di Elettronica

    1991-11-01

    SPICE is one of the most commonly used programs for the simulation of the behaviour of electronic circuits. This article describes in detail the key design characteristics and capabilities of a computer environment called SpiCAD which integrates all the different phases of SPICE based circuitry simulation on a personal computer, i.e., the tracing of the electronics scheme, simulation and visualization of the results so as to help define semiconductor device models, determine input signals, construct macro-models and convert design sketches into formats acceptable to graphic systems.

  7. Model-Based Engineering and Manufacturing CAD/CAM Benchmark.; FINAL

    International Nuclear Information System (INIS)

    Domm, T.C.; Underwood, R.S.

    1999-01-01

    The Benchmark Project was created from a desire to identify best practices and improve the overall efficiency and performance of the Y-12 Plant's systems and personnel supporting the manufacturing mission. The mission of the benchmark team was to search out industry leaders in manufacturing and evaluate their engineering practices and processes to determine direction and focus for Y-12 modernization efforts. The companies visited included several large established companies and a new, small, high-tech machining firm. As a result of this effort, changes are recommended that will enable Y-12 to become a more modern, responsive, cost-effective manufacturing facility capable of supporting the needs of the Nuclear Weapons Complex (NWC) into the 21st century. The benchmark team identified key areas of interest, both focused and general. The focus areas included Human Resources, Information Management, Manufacturing Software Tools, and Standards/Policies and Practices. Areas of general interest included Infrastructure, Computer Platforms and Networking, and Organizational Structure. The results of this benchmark showed that all companies are moving in the direction of model-based engineering and manufacturing. There was evidence that many companies are trying to grasp how to manage current and legacy data. In terms of engineering design software tools, the companies contacted were somewhere between 3-D solid modeling and surfaced wire-frame models. The manufacturing computer tools were varied, with most companies using more than one software product to generate machining data and none currently performing model-based manufacturing (MBM) from a common model. The majority of companies were closer to identifying or using a single computer-aided design (CAD) system than a single computer-aided manufacturing (CAM) system. The Internet was a technology that all companies were looking to either transport information more easily throughout the corporation or as a conduit for

  8. An intelligent interlock design support system

    International Nuclear Information System (INIS)

    Hayashi, Toshifumi; Kamiyama, Masahiko

    1990-01-01

    This paper presents an intelligent interlock design support system, called Handy. BWR plant interlocks have been designed on a conventional CAD system operating on a mini-computer based time sharing system. However, its ability to support interlock designers is limited, mainly due to the system not being capable of manipulating the interlock logic. Handy improves the design efficiency with consistent manipulation of the logic and drawings, interlock simulation, versatile database management, object oriented user interface, high resolution high speed graphics, and automatic interlock outlining with a design support expert system. Handy is now being tested by designers, and is expected to greatly contribute to their efficiency. (author)

  9. The prediction of breast cancer biopsy outcomes using two CAD approaches that both emphasize an intelligible decision process

    International Nuclear Information System (INIS)

    Elter, M.; Schulz-Wendtland, R.; Wittenberg, T.

    2007-01-01

    Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, several computer-aided diagnosis (CAD) systems have been proposed in the last several years. These systems help physicians in their decision to perform a breast biopsy on a suspicious lesion seen in a mammogram or to perform a short term follow-up examination instead. We present two novel CAD approaches that both emphasize an intelligible decision process to predict breast biopsy outcomes from BI-RADS findings. An intelligible reasoning process is an important requirement for the acceptance of CAD systems by physicians. The first approach induces a global model based on decison-tree learning. The second approach is based on case-based reasoning and applies an entropic similarity measure. We have evaluated the performance of both CAD approaches on two large publicly available mammography reference databases using receiver operating characteristic (ROC) analysis, bootstrap sampling, and the ANOVA statistical significance test. Both approaches outperform the diagnosis decisions of the physicians. Hence, both systems have the potential to reduce the number of unnecessary breast biopsies in clinical practice. A comparison of the performance of the proposed decision tree and CBR approaches with a state of the art approach based on artificial neural networks (ANN) shows that the CBR approach performs slightly better than the ANN approach, which in turn results in slightly better performance than the decision-tree approach. The differences are statistically significant (p value <0.001). On 2100 masses extracted from the DDSM database, the CRB approach for example resulted in an area under the ROC curve of A(z)=0.89±0.01, the decision-tree approach in A(z)=0.87±0

  10. Pulmonary nodules: effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system-comparison of performance between different-dose CT scans.

    Science.gov (United States)

    Yanagawa, Masahiro; Honda, Osamu; Kikuyama, Ayano; Gyobu, Tomoko; Sumikawa, Hiromitsu; Koyama, Mitsuhiro; Tomiyama, Noriyuki

    2012-10-01

    To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m(2)) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. The consensus panel found 265 non-calcified nodules ≤ 30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (pASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; pASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    Science.gov (United States)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  12. Pou5f1-dependent EGF expression controls E-cad endocytosis, cell adhesion, and zebrafish epiboly movements

    Science.gov (United States)

    Song, Sungmin; Eckerle, Stephanie; Onichtchouk, Daria; Marrs, James A.; Nitschke, Roland; Driever, Wolfgang

    2013-01-01

    Summary Initiation of motile cell behavior in embryonic development occurs during late blastula stages when gastrulation begins. At this stage, the strong adhesion of blastomeres has to be modulated to enable dynamic behavior, similar to epithelial-to-mesenchymal transitions. We show that in zebrafish MZspg embryos mutant for the stem cell transcription factor Pou5f1/Oct4, which are severely delayed in the epiboly gastrulation movement, all blastomeres are defective in E-cad endosomal trafficking and E-cad accumulates at the plasma membrane. We find that Pou5f1-dependent control of EGF expression regulates endosomal E-cad trafficking. EGFR may act via modulation of p120 activity. Loss of E-cad dynamics reduces cohesion of cells in reaggregation assays. Quantitative analysis of cell behavior indicates that dynamic E-cad endosomal trafficking is required for epiboly cell movements. We hypothesize that dynamic control of E-cad trafficking is essential to effectively generate new adhesion sites when cells move relative to each other. PMID:23484854

  13. Predicting Long-term Ischemic Events Using Routine Clinical Parameters in Patients with Coronary Artery Disease: The OPT-CAD Risk Score.

    Science.gov (United States)

    Han, Yaling; Chen, Jiyan; Qiu, Miaohan; Li, Yi; Li, Jing; Feng, Yingqing; Qiu, Jian; Meng, Liang; Sun, Yihong; Tao, Guizhou; Wu, Zhaohui; Yang, Chunyu; Guo, Jincheng; Pu, Kui; Chen, Shaoliang; Wang, Xiaozeng

    2018-06-05

    The prognosis of patients with coronary artery disease (CAD) at hospital discharge was constantly varying, and post-discharge risk of ischemic events remain a concern. However, risk prediction tools to identify risk of ischemia for these patients has not yet been reported. We sought to develop a scoring system for predicting long-term ischemic events in CAD patients receiving antiplatelet therapy that would be beneficial in appropriate personalized decision-making for these patients. In this prospective Optimal antiPlatelet Therapy for Chinese patients with Coronary Artery Disease (OPT-CAD, NCT01735305) registry, a total of 14,032 patients with CAD receiving at least one kind of antiplatelet agent were enrolled from 107 centers across China, from January 2012 to March 2014. The risk scoring system was developed in a derivation cohort (enrolled initially 10,000 patients in the database) using a logistic regression model and was subsequently tested in a validation cohort (the last 4,032 patients). Points in risk score was assigned based on the multivariable odds ratio of each factor. Ischemic events were defined as the composite of cardiac death, myocardial infarction or stroke. Ischemic events occurred in 342 (3.4%) patients in the derivation cohort and 160 (4.0%) patients in the validation cohort during 1-year follow-up. The OPT-CAD score, ranging from 0-257 points, consist of 10 independent risk factors, including age (0-71 points), heart rates (0-36 points), hypertension (0-20 points), prior myocardial infarction (16 points), prior stroke (16 points), renal insufficient (21 points), anemia (19 points), low ejection fraction (22 points), positive cardiac troponin (23 points) and ST-segment deviation (13 points). In predicting 1-year ischemic events, the area under receiver operating characteristics curve were 0.73 and 0.72 in derivation and validation cohort, respectively. The incidences of ischemic events in low- (0-90 points), medium- (91-150 points) and

  14. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses.

    Science.gov (United States)

    Yilmaz, Burak; Alp, Gülce; Seidt, Jeremy; Johnston, William M; Vitter, Roger; McGlumphy, Edwin A

    2018-01-06

    The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). Statistically significant differences were found among load-to-fracture values of different HDPs (PCAD-CAM polymer. GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers

  15. 3D-CAD Effects on Creative Design Performance of Different Spatial Abilities Students

    Science.gov (United States)

    Chang, Y.

    2014-01-01

    Students' creativity is an important focus globally and is interrelated with students' spatial abilities. Additionally, three-dimensional computer-assisted drawing (3D-CAD) overcomes barriers to spatial expression during the creative design process. Does 3D-CAD affect students' creative abilities? The purpose of this study was to explore the…

  16. Continuous Surface Rendering, Passing from CAD to Physical Representation

    Directory of Open Access Journals (Sweden)

    Mario Covarrubias

    2013-06-01

    Full Text Available This paper describes a desktop-mechatronic interface that has been conceived to support designers in the evaluation of aesthetic virtual shapes. This device allows a continuous and smooth free hand contact interaction on a real and developable plastic tape actuated by a servo-controlled mechanism. The objective in designing this device is to reproduce a virtual surface with a consistent physical rendering well adapted to designers' needs. The desktop-mechatronic interface consists in a servo-actuated plastic strip that has been devised and implemented using seven interpolation points. In fact, by using the MEC (Minimal Energy Curve Spline approach, a developable real surface is rendered taking into account the CAD geometry of the virtual shapes. In this paper, we describe the working principles of the interface by using both absolute and relative approaches to control the position on each single control point on the MEC spline. Then, we describe the methodology that has been implemented, passing from the CAD geometry, linked to VisualNastran in order to maintain the parametric properties of the virtual shape. Then, we present the co-simulation between VisualNastran and MATLAB/Simulink used for achieving this goal and controlling the system and finally, we present the results of the subsequent testing session specifically carried out to evaluate the accuracy and the effectiveness of the mechatronic device.

  17. Ovulation leads women to perceive sexy cads as good dads.

    Science.gov (United States)

    Durante, Kristina M; Griskevicius, Vladas; Simpson, Jeffry A; Cantú, Stephanie M; Li, Norman P

    2012-08-01

    Why do some women pursue relationships with men who are attractive, dominant, and charming but who do not want to be in relationships--the prototypical sexy cad? Previous research shows that women have an increased desire for such men when they are ovulating, but it is unclear why ovulating women would think it is wise to pursue men who may be unfaithful and could desert them. Using both college-age and community-based samples, in 3 studies we show that ovulating women perceive charismatic and physically attractive men, but not reliable and nice men, as more committed partners and more devoted future fathers. Ovulating women perceive that sexy cads would be good fathers to their own children but not to the children of other women. This ovulatory-induced perceptual shift is driven by women who experienced early onset of puberty. Taken together, the current research identifies a novel proximate reason why ovulating women pursue relationships with sexy cads, complementing existing research that identifies the ultimate, evolutionary reasons for this behavior.

  18. Plant introduction system applying virtual reality

    International Nuclear Information System (INIS)

    Kasai, Yasusuke; Tanaka, Kazuo; Kimura, Katsumi; Nakakosi, Tetsuhiro

    1995-01-01

    We developed the prototype of the introduction system for nuclear power plant applying 3D-CAD data and the virtual reality (V.R) technologies. For the purpose of the public acceptance (PA), the use of the V.R technologies, such as CG stereographic, will be interesting for the public. Also, it is very important to introduce the components of the plant in detail, which will become easy by using the 3D-CAD data of the nuclear plant. We made a prototype system for introducing the main portion of the nuclear power plant, such as main control room, containment vessel or turbine building, applying CG stereographic by plant 3D data and artificial voice guidance for the explanations. We have exhibited this system in two local festivals at the plant sites. It has been efficient for creating plant scene by using 3D-CAD from the viewpoint of cost, and stereographic has been much attractive to the resident. The detail scenario must be investigated from the viewpoint of PA effect. Also the performance of the graphics workstation should be increased to promote the quality of the CG movie. But we think that this system will have much effective by its novelty and flexibility. (author)

  19. Color change of CAD-CAM materials and composite resin cements after thermocycling.

    Science.gov (United States)

    Gürdal, Isil; Atay, Ayse; Eichberger, Marlis; Cal, Ebru; Üsümez, Aslihan; Stawarczyk, Bogna

    2018-04-24

    The color of resin cements and computer-aided-design and computer-aided-manufacturing (CAD-CAM) restorations may change with aging. The purpose of this in vitro study was to analyze the influence of thermocycling on the color of CAD-CAM materials with underlying resin cement. Seven different CAD-CAM materials, composite resins and glass-ceramics were cut into 0.7-mm and 1.2-mm thicknesses (n=10) and cemented with a dual-polymerizing resin cement, a light-polymerizing resin cement, and a preheated composite resin (N=420). Color values were measured by using spectrophotometry. Specimens were subjected to thermocycling (5°C and 55°C; 5000 cycles). The measured color difference (ΔE) data were analyzed by using descriptive statistics. Normality of data distribution was tested by using the Kolmogorov-Smirnov test. Three-way and 1-way ANOVA followed by the Scheffé post-hoc test and unpaired 2-sample Student t test were computed to determine the significant differences among the tested parameters (α=.05). ΔE values were significantly influenced by the CAD-CAM material (η p 2 =0.85, Pcement (η P 2 =0.03, P=.003) but were not influenced by thickness (P=.179). Significant interactions were present among thickness, cement, and CAD-CAM materials (Pcement showed significantly lower ΔE values than the preheated composite resin (P=.003). Restoration materials and composite resin cement types used for cementation influence the amount of color change due to aging. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Use, Attitudes and Knowledge of Complementary and Alternative Drugs (CADs among Pregnant Women: A Preliminary Survey in Tuscany

    Directory of Open Access Journals (Sweden)

    Francesco Lapi

    2010-01-01

    Full Text Available To explore pregnant women's use, attitudes, knowledge and beliefs of complementary and alternative drugs (CADs defined as products manufactured from herbs or with a natural origin. A preliminary survey was conducted among 172 pregnant women in their third trimester of pregnancy, consecutively recruited in two obstetrical settings; 15 women were randomly selected to compute a test-to-retest analysis. Response rate was 87.2%. Test-to-retest analysis showed a questionnaire's reproducibility exceeding a K-value of 0.7 for all items. Mean age was 32.4 ± 0.4 years; most women were nulliparae (62.7%. The majority of subjects (68% declared to have used one or more CADs during their lifetime; 48% of pregnant women reported taking at least one CAD previously and during the current pregnancy. Women's habitual use of CADs meant they were at higher risk of taking CADs also during pregnancy (adjusted odds ratio = 10.8; 95% confidence interval: 4.7–25.0. Moreover, 59.1% of the subjects were unable to correctly identify the type of CADs they were using. The majority of women resorted to gynecologists as the primary information source for CADs during pregnancy, while they mainly referred to herbalists when not pregnant. Habitual use of CADs seems to be a strong predictor for their ingestion also during pregnancy; in addition most subjects were unable to correctly identify the products they were taking. In the light of the scanty data concerning the safety of CADs during pregnancy, these preliminary results confirm the need to investigate thoroughly the situation of pregnant women and CADs consumption.

  1. The Structural Optimization System CAOS

    DEFF Research Database (Denmark)

    Rasmussen, John

    1990-01-01

    CAOS is a system for structural shape optimization. It is closely integrated in a Computer Aided Design environment and controlled entirely from the CAD-system AutoCAD. The mathematical foundation of the system is briefly presented and a description of the CAD-integration strategy is given together...

  2. CAD-CAE in Electrical Machines and Drives Teaching.

    Science.gov (United States)

    Belmans, R.; Geysen, W.

    1988-01-01

    Describes the use of computer-aided design (CAD) techniques in teaching the design of electrical motors. Approaches described include three technical viewpoints, such as electromagnetics, thermal, and mechanical aspects. Provides three diagrams, a table, and conclusions. (YP)

  3. In vitro evaluation of the marginal integrity of CAD/CAM interim crowns.

    Science.gov (United States)

    Kelvin Khng, Kwang Yong; Ettinger, Ronald L; Armstrong, Steven R; Lindquist, Terry; Gratton, David G; Qian, Fang

    2016-05-01

    The accuracy of interim crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems has not been well investigated. The purpose of this in vitro study was to evaluate the marginal integrity of interim crowns made by CAD/CAM compared with that of conventional polymethylmethacrylate (PMMA) crowns. A dentoform mandibular left second premolar was prepared for a ceramic crown and scanned for the fabrication of 60 stereolithical resin dies, half of which were scanned to fabricate 15 Telio CAD-CEREC and 15 Paradigm MZ100-E4D-E4D crowns. Fifteen Caulk and 15 Jet interim crowns were made on the remaining resin dies. All crowns were cemented with Tempgrip under a 17.8-N load, thermocycled for 1000 cycles, placed in 0.5% acid fuschin for 24 hours, and embedded in epoxy resin before sectioning from the mid-buccal to mid-lingual surface. The marginal discrepancy was measured using a traveling microscope, and dye penetration was measured as a percentage of the overall length under the crown. The mean vertical marginal discrepancy of the conventionally made interim crowns was greater than for the CAD/CAM crowns (P=.006), while no difference was found for the horizontal component (P=.276). The mean vertical marginal discrepancy at the facial surface of the Caulk crowns was significantly greater than that of the other 3 types of interim crowns (Pmargin, the mean horizontal component of the Telio crowns was significantly larger than that of the other 3 types, with no difference at the lingual margins (P=.150). The mean percentage dye penetration for the Paradigm MZ100-E4D crowns was significantly greater and for Jet crowns significantly smaller than for the other 3 crowns (Pmarginal discrepancies of the Jet interim crowns at the facial surface and with the horizontal marginal discrepancies of the Caulk interim crowns at the lingual surface (Pmarginal discrepancy was found with the interim crowns fabricated by CAD/CAM as compared with PMMA crowns

  4. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement.

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin; Tulga, Ayça

    2017-12-01

    To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) ( P CAD/CAM restorative materials was modified after treatments. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

  5. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  6. TNF-alpha-308G>A polymorphism and the risk of familial CAD in a Pakistani population.

    Science.gov (United States)

    Hussain, Sabir; Iqbal, Tahir; Javed, Qamar

    2015-01-01

    A case-control and trio-families study was performed to establish a potential association between TNF-alpha gene promoter SNPs at -308 and -238, and occurrence of CAD in a Pakistani population. In the first phase, 150 patients and 150 controls were enrolled in the case-control association study. In the second phase, heritability of susceptible alleles was investigated from 88 trio-families with CAD affected offspring. Biochemical analysis of lipids and hs-CRP was carried out spectrophotometrically, while serum TNF-alpha concentrations were determined by enzyme-linked immunosorbent assay. Genotyping of the TNF-alpha SNPs were determined by PCR-RFLP method. Elevated serum TNF-alpha and hs-CRP were observed from CAD vs. controls (PA polymorphism in case-control study revealed that the said SNP was significantly associated with the increased risk of CAD. The findings demonstrated a significant link between the TNF-alpha variant allele A at -308 and CAD (P=0.0035), whereas the -238 SNP was not associated with the disease. Haplotype A-G of the TNF-alpha gene at -308G>A and -238G>A showed higher frequency in the patient group compared with controls (PA polymorphism is associated with CAD in the study population. Furthermore, for the first time, we showed that the TNF-alpha-308A allele was significantly associated with the familial CAD in our high risk population. Copyright © 2014. Published by Elsevier Inc.

  7. Energy Efficient Mobile Operating Systems

    OpenAIRE

    Muhammad Waseem

    2013-01-01

    Energy is an important resource in mobile computers now days. It is important to manage energy in efficient manner so that energy consumption will be reduced. Developers of operating system decided to increase the battery life time of mobile phones at operating system level. So, design of energy efficient mobile operating system is the best way to reduce the energy consumption in mobile devices. In this paper, currently used energy efficient mobile operating system is discussed and compared. ...

  8. CAD-RADS™: Coronary Artery Disease - Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Radiology (ACR) and the North American Society for Cardiovascular Imaging (NASCI). Endorsed by the American College of Cardiology.

    Science.gov (United States)

    Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A

    2016-12-01

    The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 Society of Cardiovascular Computed Tomography and the American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. Combined photogrammetry and 3-D CAD for plant documentation and planning of refits

    International Nuclear Information System (INIS)

    Fraas, K.C.; Giese, U.; Kamsties, K.D.

    1991-01-01

    Meticulous advance planning and erection studies using a three-dimensional computer-aided design model of the plant area concerned can reduce the problem that unexpected events during a plant refit will prolong the required inspection period. This presupposes that a 3-D CAD scale model of the running plant has been generated. A method is described with which the as-built condition of the plant area is converted into a 3-D CAD model by combining photogrammetry with 3-D CAD. The minimum amount of time required for in-plant surveying and the completeness and clarity of results are the special advantages of this method in comparison with other measurement techniques. Selected applications are presented. (orig.) [de

  10. Evaluation of the specificity of radionuclide myocardial imaging for detecting CAD

    International Nuclear Information System (INIS)

    Liu Xiujie

    1992-01-01

    In order to evaluate the specificity of radionuclide myocardial perfusion imaging for detecting coronary artery disease (CAD), 50 patients with normal coronary arteriography and radionuclide myocardial perfusion scintigraphy were analysed. The results from 201 T1 (20 cases) and 99m Tc-MIBI (30 cases) studies showed that out of 33 patients with no organic cardiovascular disease, 29 had normal myocardial imaging, and the specificity of radionuclide myocardial imaging for detecting CAD was 87.8%. 4 normal young women had false positive myocardial imaging. Out of 17 patients with cardiovascular disease and normal coronary arteriography, 15 patients had abnormal myocardial imaging. The final clinical diagnoses of these 15 patients were: 4 patients with hypertrophic cardiomyopathy, 3 with old myocardial infarction, 2 with myocarditis, 3 with small coronary vessel disease, 1 with congestive cardiomyopathy, and 2 with other cardiac disorder. The points of differentiation between CAD and other cardiovascular disease using radionuclide techniques were discussed

  11. DESIGN OF A SUPERBIKE PADDOCK STAND USING CAD AND CAE TOOLS

    Directory of Open Access Journals (Sweden)

    M.H. Mohd Noh

    2012-06-01

    Full Text Available Two people are required to operate current superbike paddock stands in order to elevate the superbike. Lifting the superbike alone using the current design of paddock stand may be impractical and inconvenient for users. To overcome this limitation, a new design of a superbike paddock stand was conceived that could be operated by a single user. CAD and CAE tools using CATIA V5R18 software were utilised in designing this new stand. A 3D CAD model was developed and analysed through finite element analysis (FEA and a prototype fabricated for verification testing of the design. The use of CAD and CAE tools saved much time in the design work and gave the researchers and designers freedom in producing their own design. However, the most important aspect of this design study was to design a superbike paddock stand that is more practical and convenient for operation by a single user.

  12. Digital Sketch Modelling: Integrating Digital Sketching as a Transition between Sketching and CAD in Industrial Design Education

    Science.gov (United States)

    Ranscombe, Charlie; Bissett-Johnson, Katherine

    2017-01-01

    Literature on the use of design tools in educational settings notes an uneasy relationship between student use of traditional hand sketching and digital modelling tools (CAD) during the industrial design process. This is often manifested in the transition from sketching to CAD and exacerbated by a preference of current students to use CAD. In this…

  13. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin

    2017-01-01

    PURPOSE To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (Pcementation of the novel CAD/CAM restorative materials. PMID:29279763

  14. Solving polynomial systems using no-root elimination blending schemes

    KAUST Repository

    Barton, Michael

    2011-12-01

    Searching for the roots of (piecewise) polynomial systems of equations is a crucial problem in computer-aided design (CAD), and an efficient solution is in strong demand. Subdivision solvers are frequently used to achieve this goal; however, the subdivision process is expensive, and a vast number of subdivisions is to be expected, especially for higher-dimensional systems. Two blending schemes that efficiently reveal domains that cannot contribute by any root, and therefore significantly reduce the number of subdivisions, are proposed. Using a simple linear blend of functions of the given polynomial system, a function is sought after to be no-root contributing, with all control points of its BernsteinBézier representation of the same sign. If such a function exists, the domain is purged away from the subdivision process. The applicability is demonstrated on several CAD benchmark problems, namely surfacesurfacesurface intersection (SSSI) and surfacecurve intersection (SCI) problems, computation of the Hausdorff distance of two planar curves, or some kinematic-inspired tasks. © 2011 Elsevier Ltd. All rights reserved.

  15. Innovative three-dimensional neutronics analyses directly coupled with cad models of geometrically complex fusion systems

    International Nuclear Information System (INIS)

    Sawan, M.; Wilson, P.; El-Guebaly, L.; Henderson, D.; Sviatoslavsky, G.; Bohm, T.; Kiedrowski, B.; Ibrahim, A.; Smith, B.; Slaybaugh, R.; Tautges, T.

    2007-01-01

    Fusion systems are, in general, geometrically complex requiring detailed three-dimensional (3-D) nuclear analysis. This analysis is required to address tritium self-sufficiency, nuclear heating, radiation damage, shielding, and radiation streaming issues. To facilitate such calculations, we developed an innovative computational tool that is based on the continuous energy Monte Carlo code MCNP and permits the direct use of CAD-based solid models in the ray-tracing. This allows performing the neutronics calculations in a model that preserves the geometrical details without any simplification, eliminates possible human error in modeling the geometry for MCNP, and allows faster design iterations. In addition to improving the work flow for simulating complex 3- D geometries, it allows a richer representation of the geometry compared to the standard 2nd order polynomial representation. This newly developed tool has been successfully tested for a detailed 40 degree sector benchmark of the International Thermonuclear Experimental Reactor (ITER). The calculations included determining the poloidal variation of the neutron wall loading, flux and nuclear heating in the divertor components, nuclear heating in toroidal field coils, and radiation streaming in the mid-plane port. The tool has been applied to perform 3-D nuclear analysis for several fusion designs including the ARIES Compact Stellarator (ARIES-CS), the High Average Power Laser (HAPL) inertial fusion power plant, and ITER first wall/shield (FWS) modules. The ARIES-CS stellarator has a first wall shape and a plasma profile that varies toroidally within each field period compared to the uniform toroidal shape in tokamaks. Such variation cannot be modeled analytically in the standard MCNP code. The impact of the complex helical geometry and the non-uniform blanket and divertor on the overall tritium breeding ratio and total nuclear heating was determined. In addition, we calculated the neutron wall loading variation in

  16. Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader

    International Nuclear Information System (INIS)

    Beyer, F.; Zierott, L.; Juergens, K.U.; Heindel, W.; Fallenberg, E.M.; Stoeckel, J.; Wormanns, D.

    2007-01-01

    The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR. (orig.)

  17. CAD-DRASTIC: chloride application density combined with DRASTIC for assessing groundwater vulnerability to road salt application

    Science.gov (United States)

    Salek, Mansour; Levison, Jana; Parker, Beth; Gharabaghi, Bahram

    2018-06-01

    Road salt is pervasively used throughout Canada and in other cold regions during winter. For cities relying exclusively on groundwater, it is important to plan and minimize the application of salt accordingly to mitigate the adverse effects of high chloride concentrations in water supply aquifers. The use of geospatial data (road network, land use, Quaternary and bedrock geology, average annual recharge, water-table depth, soil distribution, topography) in the DRASTIC methodology provides an efficient way of distinguishing salt-vulnerable areas associated with groundwater supply wells, to aid in the implementation of appropriate management practices for road salt application in urban areas. This research presents a GIS-based methodology to accomplish a vulnerability analysis for 12 municipal water supply wells within the City of Guelph, Ontario, Canada. The chloride application density (CAD) value at each supply well is calculated and related to the measured groundwater chloride concentrations and further combined with soil media and aquifer vadose- and saturated-zone properties used in DRASTIC. This combined approach, CAD-DRASTIC, is more accurate than existing groundwater vulnerability mapping methods and can be used by municipalities and other water managers to further improve groundwater protection related to road salt application.

  18. Energy efficient lighting design for Venlo type greenhouses

    NARCIS (Netherlands)

    Janssen, E.; Zonneveldt, L.; Sools, F.

    2006-01-01

    TNO has developed a Radiance software model to calculate the light distribution in the greenhouse using raytracing methods, suitable for daylight and artificial lighting. The model is based on a 3D CAD (Computer aided design) model. The objective is to maximize the efficiency of the artificial

  19. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  20. El CAD en la actividad de reingeniería e ingeniería en los mantenimientos a centrales eléctricas // CAD in the reengineering and engineering activity in maintenance of power plants

    Directory of Open Access Journals (Sweden)

    R. García Ramírez

    2000-07-01

    Full Text Available El presente trabajo muestra algunas experiencias obtenidas en la actividad de ingeniería y reingeniería durante elmantenimiento a centrales eléctricas con empleo del CAD (Computer Aided Design, se muestran además las estrategiasseguidas con vistas a automatizar la actividad de reingeniería en ordenadores y a lograr mejoras económicas en la actividada costa de disminuir los costos de producción.Palabras claves: CAD, reingeniería, mantenimiento de calderas._________________________________________________________________________AbstractThe present work shows some experiences obtained in the engineering and reengineering during the maintenance activity inpower plants carried out by our company applying the CAD (Computer Aided Design, it is also exposed the strategyfollowed with a view to automating the reengineering activity with the use of computers, keeping in mind a view to achieveconomic improvements in the activity to diminish production costs.Key words: reengineering, CAD, maintenance, boiler.

  1. The effect of glazing and aging on the surface properties of CAD/CAM resin blocks.

    Science.gov (United States)

    Tekçe, Neslihan; Fidan, Sinan; Tuncer, Safa; Kara, Dilan; Demirci, Mustafa

    2018-02-01

    To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (R a and R z ) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test ( P .05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher R a values than Group 2 ( P .05). Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.

  2. A Case Study in CAD Design Automation

    Science.gov (United States)

    Lowe, Andrew G.; Hartman, Nathan W.

    2011-01-01

    Computer-aided design (CAD) software and other product life-cycle management (PLM) tools have become ubiquitous in industry during the past 20 years. Over this time they have continuously evolved, becoming programs with enormous capabilities, but the companies that use them have not evolved their design practices at the same rate. Due to the…

  3. The value of radionuclide phase analysis and parameters of cardial function for diagnosis CAD at rest and during exercise

    International Nuclear Information System (INIS)

    Huang Gang

    1990-01-01

    27 patients and 5 normal were studied with ECG-gated cardial blood pool images and radionuclide phase analysis at rest and during exercise. The results showed that the sensitivity of LVEF in CAD at rest and during exercise were 57% and 71% respectively, and the sensitivity of the ventricular phase in CAD were 79% at rest and 90% during exercise, and the sensitivity of phase angle in CAD were higher than of LVEF. This suggested that the ventricular phase angle was important for diagnosing early CAD. In addition, regional EF, phase image and ventricular wall motion were useful to detect the lesion of ischemia in CAD

  4. ADMultiImg: a novel missing modality transfer learning based CAD system for diagnosis of MCI due to AD using incomplete multi-modality imaging data

    Science.gov (United States)

    Liu, Xiaonan; Chen, Kewei; Wu, Teresa; Weidman, David; Lure, Fleming; Li, Jing

    2018-02-01

    Alzheimer's Disease (AD) is the most common cause of dementia and currently has no cure. Treatments targeting early stages of AD such as Mild Cognitive Impairment (MCI) may be most effective to deaccelerate AD, thus attracting increasing attention. However, MCI has substantial heterogeneity in that it can be caused by various underlying conditions, not only AD. To detect MCI due to AD, NIA-AA published updated consensus criteria in 2011, in which the use of multi-modality images was highlighted as one of the most promising methods. It is of great interest to develop a CAD system based on automatic, quantitative analysis of multi-modality images and machine learning algorithms to help physicians more adequately diagnose MCI due to AD. The challenge, however, is that multi-modality images are not universally available for many patients due to cost, access, safety, and lack of consent. We developed a novel Missing Modality Transfer Learning (MMTL) algorithm capable of utilizing whatever imaging modalities are available for an MCI patient to diagnose the patient's likelihood of MCI due to AD. Furthermore, we integrated MMTL with radiomics steps including image processing, feature extraction, and feature screening, and a post-processing for uncertainty quantification (UQ), and developed a CAD system called "ADMultiImg" to assist clinical diagnosis of MCI due to AD using multi-modality images together with patient demographic and genetic information. Tested on ADNI date, our system can generate a diagnosis with high accuracy even for patients with only partially available image modalities (AUC=0.94), and therefore may have broad clinical utility.

  5. The theory of constraints applied in a manufacture CAD-CAM system in the industry Metalworking-plastic

    Directory of Open Access Journals (Sweden)

    Luis Juiña

    2017-06-01

    Full Text Available In the following project, the theory of constraints was applied in order to implement a manufacture CAD-CAM system into the metal mechanic industry processes of polymers injection and blown of polymers. The research showed that the manufacture of the mold with the engraving took 223,17 hours. In the workflow for the manufacture of the mold, a restriction was found in the outsource service of CNC. It took 120 hours of the whole process and represent the 51,47 % the total time of tooling manufacturing. There is also a constraint found in the design time. It was 60 hours that corresponds to 26,88 % of the overall time. In order to reduce the time, a modern system of design in 3D and CAM was established to improve the model process of design and manufacture. A simulation by computational resource was applied to the plastic. The design was changed from 2D to 3D. The implementation was focused in the design. A software was installed to improve the speed of modeling methods with reliable information. In the manufacture of molds, a new CNC machine was acquired with three simultaneous axes to eliminate the outsource service. By acquiring the design system, the working time was diminished in 79% and regarding to the CNC process, the working time was improved in 88%.

  6. Use of Existing CAD Models for Radiation Shielding Analysis

    Science.gov (United States)

    Lee, K. T.; Barzilla, J. E.; Wilson, P.; Davis, A.; Zachman, J.

    2015-01-01

    The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

  7. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    Science.gov (United States)

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  8. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    Science.gov (United States)

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  9. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Qinghua Huang

    2018-01-01

    Full Text Available The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  10. Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study.

    Science.gov (United States)

    Sonmez, Nesrin; Gultekin, Pinar; Turp, Volkan; Akgungor, Gokhan; Sen, Deniz; Mijiritsky, Eitan

    2018-01-08

    Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey's HSD, and Student's t tests (α = .05). Fractured specimens were evaluated using SEM. The highest Vickers microhardness value was found for VITA Mark II (p CAD was found to have the highest flexural strength (p CAD was also higher than other tested block materials (p CAD groups. It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics.

  11. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    Science.gov (United States)

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from

  12. Incorporation of composite defects from ultrasonic NDE into CAD and FE models

    Science.gov (United States)

    Bingol, Onur Rauf; Schiefelbein, Bryan; Grandin, Robert J.; Holland, Stephen D.; Krishnamurthy, Adarsh

    2017-02-01

    Fiber-reinforced composites are widely used in aerospace industry due to their combined properties of high strength and low weight. However, owing to their complex structure, it is difficult to assess the impact of manufacturing defects and service damage on their residual life. While, ultrasonic testing (UT) is the preferred NDE method to identify the presence of defects in composites, there are no reasonable ways to model the damage and evaluate the structural integrity of composites. We have developed an automated framework to incorporate flaws and known composite damage automatically into a finite element analysis (FEA) model of composites, ultimately aiding in accessing the residual life of composites and make informed decisions regarding repairs. The framework can be used to generate a layer-by-layer 3D structural CAD model of the composite laminates replicating their manufacturing process. Outlines of structural defects, such as delaminations, are automatically detected from UT of the laminate and are incorporated into the CAD model between the appropriate layers. In addition, the framework allows for direct structural analysis of the resulting 3D CAD models with defects by automatically applying the appropriate boundary conditions. In this paper, we show a working proof-of-concept for the composite model builder with capabilities of incorporating delaminations between laminate layers and automatically preparing the CAD model for structural analysis using a FEA software.

  13. Survey on the use of CAD-CAM technology by UK and Irish dental technicians.

    Science.gov (United States)

    Blackwell, E; Nesbit, M; Petridis, H

    2017-05-12

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dental technicians' use and reporting of this technology.Purpose The aim of this cross sectional survey was to identify the extent digital technology has infiltrated the workplace and to investigate the factors affecting the use of CAD-CAM technology by dental laboratory technicians within Ireland and the UK.Materials and methods A web-based questionnaire was composed (Opinio, Object Planet Inc. Oslo, Norway) and distributed to UK and Irish dental technicians. Answers to all questions were anonymous and grouped such that general information was gathered initially, followed by branching of the survey into two sections depending on whether or not the respondent worked with CAD-CAM technology. Results were compiled and statistical analysis (Fisher's Exact test, SPSS, IBM, Armonk, New York, USA) was performed in order to investigate any correlation between various demographic variables and the answers provided.Results The survey was distributed to 760 UK technicians and 77 Irish technicians. The total number of completed surveys was 105, which yielded a total response rate of 14%. Most technicians reported using some form of CAD/CAM aspect in the workflow, and this was more significant for technicians working in large laboratories. Most training received was company-led. Large laboratories were also significantly correlated with less outsourcing of CAD/CAM work and a change in dental material use leading to the increase of zirconia and the decrease of noble alloys. Dental technicians did not report any significant change in working relationships and staffing as a result of CAD/CAM incorporation. High initial investment cost was the most common reason quoted from non-users, along with the lack of such technology in their working environment.

  14. Metabolite profiling reveals a role for atypical cinnamyl alcohol dehydrogenase CAD1 in the synthesis of coniferyl alcohol in tobacco xylem.

    Science.gov (United States)

    Damiani, Isabelle; Morreel, Kris; Danoun, Saïda; Goeminne, Geert; Yahiaoui, Nabila; Marque, Christiane; Kopka, Joachim; Messens, Eric; Goffner, Deborah; Boerjan, Wout; Boudet, Alain-Michel; Rochange, Soizic

    2005-11-01

    In angiosperms, lignin is built from two main monomers, coniferyl and sinapyl alcohol, which are incorporated respectively as G and S units in the polymer. The last step of their synthesis has so far been considered to be performed by a family of dimeric cinnamyl alcohol dehydrogenases (CAD2). However, previous studies on Eucalyptus gunnii xylem showed the presence of an additional, structurally unrelated, monomeric CAD form named CAD1. This form reduces coniferaldehyde to coniferyl alcohol, but is inactive on sinapaldehyde. In this paper, we report the functional characterization of CAD1 in tobacco (Nicotiana tabacum L.). Transgenic tobacco plants with reduced CAD1 expression were obtained through an RNAi strategy. These plants displayed normal growth and development, and detailed biochemical studies were needed to reveal a role for CAD1. Lignin analyses showed that CAD1 down-regulation does not affect Klason lignin content, and has a moderate impact on G unit content of the non-condensed lignin fraction. However, comparative metabolic profiling of the methanol-soluble phenolic fraction from basal xylem revealed significant differences between CAD1 down-regulated and wild-type plants. Eight compounds were less abundant in CAD1 down-regulated lines, five of which were identified as dimers or trimers of monolignols, each containing at least one moiety derived from coniferyl alcohol. In addition, 3-trans-caffeoyl quinic acid accumulated in the transgenic plants. Together, our results support a significant contribution of CAD1 to the synthesis of coniferyl alcohol in planta, along with the previously characterized CAD2 enzymes.

  15. Unique CAD/CAM three-quarter crown restoration of a central incisor: a case report.

    Science.gov (United States)

    Goldberg, Marvin B; Siegel, Sharon C; Rezakani, Niloufar

    2013-07-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) dentistry has been in use for more than 2 decades. Recent improvements in this technology have made CAD/CAM restorations a viable alternative for routine dental care. This technology is being taught in dental schools to prepare students for contemporary dental practice and is particularly useful in unique restorative situations that allow conservation of tooth structure. This case report describes the restoration of a central incisor that was previously restored with an unesthetic three-quarter gold crown. The tooth exhibited recurrent caries and an unaffected labial wall of supported enamel. A CAD/CAM three-quarter crown was planned to conserve tooth structure. After preparation, the tooth was scanned for a CAD/CAM crown in order to fabricate a ceramic restoration, which was then milled and bonded, producing an esthetic result. Typically, in cases of esthetic enhancement, a labial laminate restoration is fabricated, but in this situation, a different approach was necessary to make a design for the lingual surface of an anterior tooth.

  16. Information technology in the strategy of digestive surgery. (2) Advances of CAD system using OsiriX

    International Nuclear Information System (INIS)

    Sugimoto, Maki; Yasuda, Hideki; Koda, Keiji; Yamazaki, Masato; Tezuka, Tohru; Kosugi, Chihiro; Watayo, Yoshihisa; Naka, Shuji

    2007-01-01

    OsiriX, one of information technology (IT) product in medicine, is an image processing system developed by surgeons and its software for Mac OS can be installed free of charge (http://homepage.mac.com/rossetantoine/osrix/). The present review describes the practical application of this computer-aided diagnostic (CAD) tool mainly in the field of surgery of hepato-biliary-pancreatic system. Authors are successfully utilizing the OsiriX for pre-operative diagnosis by modalities of multidetector-row CT (MDCT), MRI and PET images, for simulation of surgery by volume rendering, carbon dioxide MDCT cholangiopancreatography (CMCP), 3D vascular construction MDCT angiography and virtual reality, and for navigation during the actual operation. The machine they use is 16-row MDCT LightSpeed Ultra 16 (GE Healthcare), and their data are processed through the Digital Imaging and Communications in Medicine (DICOM) viewer OsiriX 2.6, Power Mac G5, MacBook Pro (Apple Computer, Inc.) and 3D image processing engine (TeraRecon, Inc.). Presented are details of decision of region of interest (ROI), 3D ROI extraction by region-growing, MacBook Pro and iPod, and IT surgery by OsiriX, which are still being improved day by day. (T.I.)

  17. Metodología para la manufactura de implantes craneales a partir de imágenes DICOM y tecnologías CAD/CAM/CNC Metodología para la manufactura de implantes craneales a partir de imágenes DICOM y tecnologías CAD/CAM/CNC

    Directory of Open Access Journals (Sweden)

    Iván López

    2005-12-01

    Full Text Available El presente artículo propone una metodología para el diseño y la fabricación de implantes craneales a partir de imágenes DICOM y tecnologías CAD/CAM/CNC. Esta metodología parte de las Tomografías Axiales Computarizadas (TAC de la cabeza del paciente, con las cuales se lleva a cabo la reconstrucción tridimensional del cráneo. Luego, en el sistema CAD se reconstruye el implante variando la técnica empleada dependiendo de la región del cráneo con defecto o trauma. Una vez obtenido el modelo, se diseña el montaje y se fabrica el implante con soporte en tecnología CAM/CNC.It’s proposed a methodology in order to design and manufacture cranial implants using DICOM and CAD/CAM/CNC technologies. This methodology begins when the designer makes a three-dimensional cranial reconstruction using the Axial Computer Tomographies (ACT of the patient’s cranium. Next, using a CAD system, the designer rebuilds the implant varying the used technique depending on the affected region. Finally, the designer builds the assembling and manufactures the implant.

  18. Circulating irisin levels are lower in patients with either stable coronary artery disease (CAD) or myocardial infarction (MI) versus healthy controls, whereas follistatin and activin A levels are higher and can discriminate MI from CAD with similar to CK-MB accuracy.

    Science.gov (United States)

    Anastasilakis, Athanasios D; Koulaxis, Dimitrios; Kefala, Nikoleta; Polyzos, Stergios A; Upadhyay, Jagriti; Pagkalidou, Eirini; Economou, Fotios; Anastasilakis, Chrysostomos D; Mantzoros, Christos S

    2017-08-01

    Several myokines are produced by cardiac muscle. We investigated changes in myokine levels at the time of acute myocardial infarction (MI) and following reperfusion in relation to controls. Patients with MI (MI Group, n=31) treated with percutaneous coronary intervention (PCI) were compared to patients with stable coronary artery disease (CAD) subjected to scheduled PCI (CAD Group, n=40) and controls with symptoms mimicking CAD without stenosis in angiography (Control Group, n=43). The number and degree of stenosis were recorded. Irisin, follistatin, follistatin-like 3, activin A and B, ALT, AST, CK and CK-MB were measured at baseline and 6 or 24h after the intervention. MI and CAD patients had lower irisin than controls (p<0.001). MI patients had higher follistatin, activin A, CK, CK-MB and AST than CAD patients and controls (all p≤0.001). None of the myokines changed following reperfusion. Circulating irisin was associated with the degree of stenosis in all patients (p=0.05). Irisin was not inferior to CK-MB in predicting MI while folistatin and activin A could discriminate MI from CAD patients with similar to CK-MB accuracy. None of these myokines was altered following PCI in contrast to CK-MB. Irisin levels are lower in MI and CAD implying that their production may depend on myocadial blood supply. Follistatin and activin A are higher in MI than in CAD suggesting increased release due to myocardial necrosis. They can predict MI with accuracy similar to CK-MB and their role in the diagnosis of MI remains to be confirmed by prospective large clinical studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    International Nuclear Information System (INIS)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo; Pitocco, Dario; Di Stasio, Enrico; Trani, Carlo

    2016-01-01

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  20. MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Savino, Giancarlo; Merlino, Biagio; Pirro, Federica; Rutigliano, Claudia; Santangelo, Carolina; Minoiu, Aurelian Costin; Natale, Luigi; Bonomo, Lorenzo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Radiological Sciences - Institute of Radiology, Rome (Italy); Pitocco, Dario [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Internal Medicine, Rome (Italy); Di Stasio, Enrico [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Clinical Biochemistry, Rome (Italy); Trani, Carlo [Catholic University of Rome, ' ' A. Gemelli' ' University Hospital, Department of Cardiovascular Medicine - Institute of Cardiology, Rome (Italy)

    2016-03-15

    To compare the CACS and CAD severity assessed by MDCT in neuropathic type-2 diabetic patients with and without Charcot-neuroarthropathy (CN). Thirty-four CN asymptomatic-patients and 36 asymptomatic-patients with diabetic-neuropathy (DN) without CN underwent MDCT to assess CACS and severity of CAD. Patients were classified as positive for significant CAD in presence of at least one stenosis >50 % on MDCT-coronary-angiography (MDCT-CA). Groups were matched for age, sex and traditional CAD risk-factors. The coronary-angiography (CA) was performed in all patients with at least a significant stenosis detected by MDCT-CA, both as reference and eventually as treatment. CN patients showed higher rates of significant CAD in comparison with DN subjects [p < 0.001], while non-significant differences were observed in CACS (p = 0.980). No significant differences were also observed in CACS distribution in all subjects for stenosis ≥/<50 % (p = 0.814), as well as in both groups (p = 0.661 and 0.559, respectively). The MDCT-CA showed an overall diagnostic-accuracy for significant CAD of 87 %. These preliminary data suggest that CN-patients have a higher prevalence of severe CAD in comparison with DN-patients, while coronary plaques do not exhibit an increased amount of calcium. MDCT may be helpful to assess the CV risk in such asymptomatic type-2-diabetic patients with autonomic-neuropathy. (orig.)

  1. Rapid proto typing of dental prosthesis by means of a feldspathic glass composite mixed with muscovite mica via CAD/CAM; Prototipagem rapida de proteses dentarias por meio de um composito de vidro feldspatico misturado com mica moscovita via CAD/CAM

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Junior, E.S.; Gomes Junior, G.G.; Fonseca, M.D.; Moraes, E.E.S.; Ogasawara, T., E-mail: edil@metalmat.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Metalurgica e Materiais

    2010-07-01

    The work consists in the use and integration of CAD/CAM tools as a process of design and manufacture of a rapid prototyping of dental prosthesis by machining using a CNC milling machine. The material machined to obtain the dental prosthesis were cylindrical blocks of a Feldspathic glass composite mixed with muscovite mica in various percentages (15%, 40% and 80%), which was resigned under biaxial pressing and sintered in vacuum at temperatures from 800 to 1100 deg C. The composite was characterized by XRD and SEM. The results show that increasing the crystallization of leucite is consequent to the temperature increase, and that the use of CAD/CAM system using a CNC milling machine is feasible to obtain dental prosthesis. (author)

  2. The N4 CAD chain: Another electricite de France breakthrough in nuclear engineering

    International Nuclear Information System (INIS)

    Cornon, P.; Durey, P.

    1996-01-01

    With the previous pressurized water reactor (PWR) series (1300 MW), Electricite de France (EdF) has experienced the first chain of computer-aided design (CAD) tools from programming drawings to instrumentation and control microprocessor memories. The Engineering and Construction Division of EdF decided to integrate the CAD tools in the design and construction process of its new N4 series (1400-MW PWR). At that time, EdF determined four safety and data quality principles for the human/machine interface of the CAD: 1. Unique data capture: A common alphanumeric database shares all the information used by more than one application, so this information is typed only once and can be verified independently. 2. Intrinsic consistency: Added to the previous principle, data consistency is also ensured by every application that provides ways to enter only allowed data when it is possible. This is completed by some checking facilities. 3. Ergonomy: Making extensive use of windows, buttons, pictures, and wysiwyg facilities, the CAD section develops applications speaking the real language of every designer who is able to understand and verify her/his work. 4. On-line help: For any question, prompted by any application, some on-line help has been written giving the list of allowed answers with explanations and/or examples

  3. CAD CONSTRUCTION METHOD OF 3D BUILDING MODELS FOR GIS ANALYSIS

    Directory of Open Access Journals (Sweden)

    P. Boguslawski

    2012-07-01

    Full Text Available Buildings are often modelled as two-dimensional (2D footprints which are extruded to simple cubes. Buildings are also represented as more complex objects with roofs, facades, etc. – in this case they are polyhedra, sometimes of a complex shape. These allow for visualisation and analysis of a wide area like a city, but micro-scale analysis of interiors is not possible. An example can be rescue operation simulation where information about the internal structure of a building and the external terrain is crucial to improve the response time. It demands a three-dimensional (3D model where each room is represented as a separate element; there are also doors, windows, walls and other objects that have to be included. Even complex geometrical models can be easily constructed using Computer-Aided Design (CAD systems. However, lack of semantic information and topological relations makes such models poor choices for GIS analysis. With the new dual half-edge (DHE data structure and a set of Euler operators a 3D model can be built as in CAD systems, and represented as a cell complex. Construction of non-manifold objects is also possible. An advantage of the DHE is simplicity – only edges and nodes are used. Because of the 3D duality implemented in the structure volumes (cells and faces are also present in the model. The geometry of a model is constructed explicitly by using Euler operators: connections between elements are created automatically, and semantic information is represented with attributes which can be assigned to any element of the model.

  4. Advances in computer-aided engineering : CAD/CAM-research at Delft University of Technology. Report of the VF-project CAD/CAM 1989-1994

    NARCIS (Netherlands)

    Undetermined, U.

    1994-01-01

    This book contains a collection of articles describing on-going CAD/CAM-research at several engineering faculties at Delft University of Technology. Two main themes covered in this book are 'Conceptual design of complex products' and 'Product modelling and product data exchange'.

  5. Integrating 3D CAD data for manufacturing and fabrication the core model of reactor TRIGA PUSPATI

    International Nuclear Information System (INIS)

    Abu Bakar Harun

    2005-01-01

    This paper describe the intrigue integration of digital 3 Dimensional Computer Aided Design (3D CAD) data manipulation for the Core Model fabrication of REAKTOR TRIGA PUSPATI and ready for mass manufacturing. 3 Dimensional CAD data from Computer Aided Design program will be used as an interpreter in the fabrication of this project. The Core Model of REAKTOR TRIGA PUSPATI will be fabricated with the aid of 3D CAD drawings and digital files. The components will be segregated and divided into 2 categories namely Conventional d Rapid Fabrication. (Author)

  6. Progress in the integration of the ITER plant systems in auxiliary buildings

    International Nuclear Information System (INIS)

    Kotamäki, M.; Cordier, J.-J.; Kuehn, I.; Perrin, J.-L.; Sweeney, S.; Villedary, B.

    2016-01-01

    Highlights: • Usage of 3D CAD model in ITER configuration management presented. • 3D CAD models efficient in configuration and interface management. • Costly and schedule delaying changes avoided with proper interface management. • ITER buildings construction progressing. - Abstract: The ITER Tokamak machine is located in the center of Tokamak complex buildings consisting of Tokamak, Diagnostic, and Tritium buildings. Around the Tokamak complex there are over 30 auxiliary buildings housing various plant systems serving the Tokamak machine either directly or indirectly. The layout and space allocation of each auxiliary building and plant systems housed by the building are represented in the so-called Configuration Management Models (CMM). These are light 3D CAD models that define the required space envelope and the physical interfaces between the systems and the buildings and in-between the systems. The paper describes the CMM and interface management processes of the ITER auxiliary buildings and plant systems, and discusses the preparations for the plant installation phase. In addition, the current baseline configuration of the ITER plant systems in auxiliary buildings is described together with the recent developments in the configuration of different systems, as well as the current status of the construction of the buildings.

  7. Progress in the integration of the ITER plant systems in auxiliary buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kotamäki, M., E-mail: miikka.kotamaki@iter.org; Cordier, J.-J.; Kuehn, I.; Perrin, J.-L.; Sweeney, S.; Villedary, B.

    2016-11-01

    Highlights: • Usage of 3D CAD model in ITER configuration management presented. • 3D CAD models efficient in configuration and interface management. • Costly and schedule delaying changes avoided with proper interface management. • ITER buildings construction progressing. - Abstract: The ITER Tokamak machine is located in the center of Tokamak complex buildings consisting of Tokamak, Diagnostic, and Tritium buildings. Around the Tokamak complex there are over 30 auxiliary buildings housing various plant systems serving the Tokamak machine either directly or indirectly. The layout and space allocation of each auxiliary building and plant systems housed by the building are represented in the so-called Configuration Management Models (CMM). These are light 3D CAD models that define the required space envelope and the physical interfaces between the systems and the buildings and in-between the systems. The paper describes the CMM and interface management processes of the ITER auxiliary buildings and plant systems, and discusses the preparations for the plant installation phase. In addition, the current baseline configuration of the ITER plant systems in auxiliary buildings is described together with the recent developments in the configuration of different systems, as well as the current status of the construction of the buildings.

  8. Light irradiance through novel CAD-CAM block materials and degree of conversion of composite cements.

    Science.gov (United States)

    Lise, Diogo Pedrollo; Van Ende, Annelies; De Munck, Jan; Yoshihara, Kumiko; Nagaoka, Noriyuki; Cardoso Vieira, Luiz Clovis; Van Meerbeek, Bart

    2018-02-01

    To assess light irradiance (LI) delivered by two light-curing units (LCU's) and to measure the degree of conversion (DC) of three composite cements, when cured through different thicknesses of two novel CAD-CAM block materials. 100-μm-thick films of a dual-curable composite cement (G-CEM LinkAce, GC), a light-curable flowable resin-based composite (RBC) (G-ænial Universal Flo, GC) and a micro-hybrid RBC (G-ænial Posterior, GC) were investigated as luting agents. Two 'polymer-ceramic' CAD-CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were sectioned in slabs with different thicknesses (1, 3 and 5mm). LI at the bottom of the specimens was measured using a calibrated spectrometer, while being light-cured through the CAD-CAM block slabs for 40s with a low- (±500mW/cm 2 ) or high- (±1,600mW/cm 2 ) irradiance LCU (n=5). After light-curing, micro-Raman spectra of the composite films were acquired to determine DC at 5min, 10min, 1h and 24h. LI data were statistically analyzed by Kruskal-Wallis followed by post-hoc comparisons, while a linear mixed-effect model was applied for the DC analysis. In addition, the CAD-CAM blocks ultrastructure was characterized upon argon-ion slicing using scanning transmission electron microscopy (STEM). Finally, light transmission (LT) through each CAD-CAM block material was assessed using a spectrophotometer. Curing-light attenuation and DC were significantly influenced by thickness and type of the overlying material. LCU only had a significant effect on DC of the micro-hybrid RBC. DC significantly increased over time for all composite cements. CAD-CAM block structural analysis revealed a relatively small and homogenous filler configuration (mean filler size of 0.2-0.5μm) for Cerasmart, while Enamic contained ceramic grains varying in shape and size (1-10μm), which were interconnected by the polymer-based network. LT was much higher at a wavelength range of 300-800nm for Cerasmart than for Enamic. Light-curable composite cements

  9. Efficiency Evaluation of Energy Systems

    CERN Document Server

    Kanoğlu, Mehmet; Dinçer, İbrahim

    2012-01-01

    Efficiency is one of the most frequently used terms in thermodynamics, and it indicates how well an energy conversion or process is accomplished. Efficiency is also one of the most frequently misused terms in thermodynamics and is often a source of misunderstanding. This is because efficiency is often used without being properly defined first. This book intends to provide a comprehensive evaluation of various efficiencies used for energy transfer and conversion systems including steady-flow energy devices (turbines, compressors, pumps, nozzles, heat exchangers, etc.), various power plants, cogeneration plants, and refrigeration systems. The book will cover first-law (energy based) and second-law (exergy based) efficiencies and provide a comprehensive understanding of their implications. It will help minimize the widespread misuse of efficiencies among students and researchers in energy field by using an intuitive and unified approach for defining efficiencies. The book will be particularly useful for a clear ...

  10. Energy-efficient fault-tolerant systems

    CERN Document Server

    Mathew, Jimson; Pradhan, Dhiraj K

    2013-01-01

    This book describes the state-of-the-art in energy efficient, fault-tolerant embedded systems. It covers the entire product lifecycle of electronic systems design, analysis and testing and includes discussion of both circuit and system-level approaches. Readers will be enabled to meet the conflicting design objectives of energy efficiency and fault-tolerance for reliability, given the up-to-date techniques presented.

  11. Randomized controlled within-subject evaluation of digital and conventional workflows for the fabrication of lithium disilicate single crowns. Part II: CAD-CAM versus conventional laboratory procedures.

    Science.gov (United States)

    Sailer, Irena; Benic, Goran I; Fehmer, Vincent; Hämmerle, Christoph H F; Mühlemann, Sven

    2017-07-01

    Clinical studies are needed to evaluate the entire digital and conventional workflows in prosthetic dentistry. The purpose of the second part of this clinical study was to compare the laboratory production time for tooth-supported single crowns made with 4 different digital workflows and 1 conventional workflow and to compare these crowns clinically. For each of 10 participants, a monolithic crown was fabricated in lithium disilicate-reinforced glass ceramic (IPS e.max CAD). The computer-aided design and computer-aided manufacturing (CAD-CAM) systems were Lava C.O.S. CAD software and centralized CAM (group L), Cares CAD software and centralized CAM (group iT), Cerec Connect CAD software and lab side CAM (group CiL), and Cerec Connect CAD software with centralized CAM (group CiD). The conventional fabrication (group K) included a wax pattern of the crown and heat pressing according to the lost-wax technique (IPS e.max Press). The time for the fabrication of the casts and the crowns was recorded. Subsequently, the crowns were clinically evaluated and the corresponding treatment times were recorded. The Paired Wilcoxon test with the Bonferroni correction was applied to detect differences among treatment groups (α=.05). The total mean (±standard deviation) active working time for the dental technician was 88 ±6 minutes in group L, 74 ±12 minutes in group iT, 74 ±5 minutes in group CiL, 92 ±8 minutes in group CiD, and 148 ±11 minutes in group K. The dental technician spent significantly more working time for the conventional workflow than for the digital workflows (P.05). Irrespective of the CAD-CAM system, the overall laboratory working time for a digital workflow was significantly shorter than for the conventional workflow, since the dental technician needed less active working time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Synergism of the method of characteristics and CAD technology for neutron transport calculation

    International Nuclear Information System (INIS)

    Chen, Z.; Wang, D.; He, T.; Wang, G.; Zheng, H.

    2013-01-01

    The method of characteristics (MOC) is a very popular methodology in neutron transport calculation and numerical simulation in recent decades for its unique advantages. One of the key problems determining whether the MOC can be applied in complicated and highly heterogeneous geometry is how to combine an effective geometry processing method with MOC. Most of the existing MOC codes describe the geometry by lines and arcs with extensive input data, such as circles, ellipses, regular polygons and combination of them. Thus they have difficulty in geometry modeling, background meshing and ray tracing for complicated geometry domains. In this study, a new idea making use of a CAD solid modeler MCAM which is a CAD/Image-based Automatic Modeling Program for Neutronics and Radiation Transport developed by FDS Team in China was introduced for geometry modeling and ray tracing of particle transport to remove these geometrical limitations mentioned above. The diamond-difference scheme was applied to MOC to reduce the spatial discretization error of the flat flux approximation in theory. Based on MCAM and MOC, a new MOC code was developed and integrated into SuperMC system, which is a Super Multi-function Computational system for neutronics and radiation simulation. The numerical testing results demonstrated the feasibility and effectiveness of the new idea for geometry treatment in SuperMC. (authors)

  13. Bridging CAGD knowledge into CAD/CG applications: Mathematical theories as stepping stones of innovations

    Science.gov (United States)

    Gobithaasan, R. U.; Miura, Kenjiro T.; Hassan, Mohamad Nor

    2014-07-01

    Computer Aided Geometric Design (CAGD) which surpasses the underlying theories of Computer Aided Design (CAD) and Computer Graphics (CG) has been taught in a number of Malaysian universities under the umbrella of Mathematical Sciences' faculty/department. On the other hand, CAD/CG is taught either under the Engineering or Computer Science Faculty. Even though CAGD researchers/educators/students (denoted as contributors) have been enriching this field of study by means of article/journal publication, many fail to convert the idea into constructive innovation due to the gap that occurs between CAGD contributors and practitioners (engineers/product/designers/architects/artists). This paper addresses this issue by advocating a number of technologies that can be used to transform CAGD contributors into innovators where immediate impact in terms of practical application can be experienced by the CAD/CG practitioners. The underlying principle of solving this issue is twofold. First would be to expose the CAGD contributors on ways to turn mathematical ideas into plug-ins and second is to impart relevant CAGD theories to CAD/CG to practitioners. Both cases are discussed in detail and the final section shows examples to illustrate the importance of turning mathematical knowledge into innovations.

  14. FROM CAD MODEL TO 3D PRINT VIA “STL” FILE FORMAT

    Directory of Open Access Journals (Sweden)

    Cătălin IANCU

    2010-06-01

    Full Text Available The paper work presents the STL file format, which is now used for transferring information from CAD software to a 3D printer, for obtaining the solid model in Rapid prototyping and Computer Aided Manufacturing. It’s presented also the STL format structure, its history, limitations and further development, as well as its new version to arrive and other similar file formats. As a conclusion, STL files used to transfer data from CAD package to 3D printers has a series of limitations and therefore new formats will replace it soon.

  15. Mobile Technology and CAD Technology Integration in Teaching Architectural Design Process for Producing Creative Product

    Science.gov (United States)

    Bin Hassan, Isham Shah; Ismail, Mohd Arif; Mustafa, Ramlee

    2011-01-01

    The purpose of this research is to examine the effect of integrating the mobile and CAD technology on teaching architectural design process for Malaysian polytechnic architectural students in producing a creative product. The website is set up based on Caroll's minimal theory, while mobile and CAD technology integration is based on Brown and…

  16. IPAD 2: Advances in Distributed Data Base Management for CAD/CAM

    Science.gov (United States)

    Bostic, S. W. (Compiler)

    1984-01-01

    The Integrated Programs for Aerospace-Vehicle Design (IPAD) Project objective is to improve engineering productivity through better use of computer-aided design and manufacturing (CAD/CAM) technology. The focus is on development of technology and associated software for integrated company-wide management of engineering information. The objectives of this conference are as follows: to provide a greater awareness of the critical need by U.S. industry for advancements in distributed CAD/CAM data management capability; to present industry experiences and current and planned research in distributed data base management; and to summarize IPAD data management contributions and their impact on U.S. industry and computer hardware and software vendors.

  17. A Virtual CAD Model of the LHC

    CERN Document Server

    Chemli, S; Messerli, R; Muttoni, Y; Prin, H; Van Uytvinck, E

    2000-01-01

    Integrating the large and complex LHC machine into the existing LEP tunnel is a major challenge. Space was not really a problem to fit the LEP machine into its tunnel, but LHC cryostats are much larger than the LEP quadrupoles and the external cryogenic line fills even more the tunnel. Space problems lead to small clearances. Possible conflicts, or at least the most penalising ones, between installed equipment or with transport, must be solved beforehand in order to avoid unacceptable delays and extra costs during the installation. Experience gained with LEP has already shown the help that Computer-Aided Engineering tools could provide for the integration. A virtual model of the LHC is presently prepared. The actual LEP tunnel, known with a quite good accuracy (centimetre level), has been modelled and all the elements of the machine constructed as 3D objects with the CAD system are positioned accurately on the basis of data generated from the theoretical definition. These layouts are used to generate the refe...

  18. Análisis geométrico de un perfil alar mediante técnicas CAD

    OpenAIRE

    Suffo, Miguel

    2016-01-01

    Los resultados del aprendizaje de este tutorial deben ser, entre otros: - Conocer las técnicas CAD orientadas al análisis de curvatura de formas geométricas - Saber aplicar entidades geométricas de curvas complejas en diseño aeronáutico - Comparar diferentes herramientas CAD para un mismo propósito

  19. Probability Density Functions for the CALIPSO Lidar Version 4 Cloud-Aerosol Discrimination (CAD) Algorithm

    Science.gov (United States)

    Liu, Z.; Kar, J.; Zeng, S.; Tackett, J. L.; Vaughan, M.; Trepte, C. R.; Omar, A. H.; Hu, Y.; Winker, D. M.

    2017-12-01

    In the CALIPSO retrieval algorithm, detection layers in the lidar measurements is followed by their classification as a "cloud" or "aerosol" using 5-dimensional probability density functions (PDFs). The five dimensions are the mean attenuated backscatter at 532 nm, the layer integrated total attenuated color ratio, the mid-layer altitude, integrated volume depolarization ratio and latitude. The new version 4 (V4) level 2 (L2) data products, released in November 2016, are the first major revision to the L2 product suite since May 2010. Significant calibration changes in the V4 level 1 data necessitated substantial revisions to the V4 L2 CAD algorithm. Accordingly, a new set of PDFs was generated to derive the V4 L2 data products. The V4 CAD algorithm is now applied to layers detected in the stratosphere, where volcanic layers and occasional cloud and smoke layers are observed. Previously, these layers were designated as `stratospheric', and not further classified. The V4 CAD algorithm is also applied to all layers detected at single shot (333 m) resolution. In prior data releases, single shot detections were uniformly classified as clouds. The CAD PDFs used in the earlier releases were generated using a full year (2008) of CALIPSO measurements. Because the CAD algorithm was not applied to stratospheric features, the properties of these layers were not incorporated into the PDFs. When building the V4 PDFs, the 2008 data were augmented with additional data from June 2011, and all stratospheric features were included. The Nabro and Puyehue-Cordon volcanos erupted in June 2011, and volcanic aerosol layers were observed in the upper troposphere and lower stratosphere in both the northern and southern hemispheres. The June 2011 data thus provides the stratospheric aerosol properties needed for comprehensive PDF generation. In contrast to earlier versions of the PDFs, which were generated based solely on observed distributions, construction of the V4 PDFs considered the

  20. Fatigue resistance of CAD/CAM resin composite molar crowns.

    NARCIS (Netherlands)

    Shembish, F.A.; Tong, H.; Kaizer, M.; Janal, M.N.; Thompson, V.P.; Opdam, N.J.M.; Zhang, Y.

    2016-01-01

    OBJECTIVE: To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. METHODS: Fully anatomically shaped monolithic resin composite molar crowns (Lava