WorldWideScience

Sample records for effects building cleaning

  1. Measuring the effect of cleaning in buildings

    International Nuclear Information System (INIS)

    Dahl, Inger

    2001-01-01

    Traditionally, the requirements imposed on cleaning quality have been a subject of subjective judgement. A Scandinavian standard (NS-INSTA 800) has now been agreed upon by the Nordic countries and is described in this article. The goal of the standard is to describe a quality measurement system that will make it easier to define different cleaning qualities and thus to help customer and supplier to specify clearly defined requirements. The new standard describes in detail how to measure the cleaning quality and how much dirt should be allowed to remain within each level of quality. The standard describes five quality levels and the measurements are taken on four different surface categories: furniture and fixtures, floors, walls and roofs. Four types of dirt are defined: waste and loose dirt, dust, spots and surface dirt. The cleaning quality achieved is judged by visually counting all impurities on easily accessible surfaces and on surfaces with difficult access (very small horizontal surfaces, horizontal surfaces above 180 cm, panelled ceiling etc)

  2. Effective Pneumatic Scheme and Control Strategy of a Climbing Robot for Class Wall Cleaning on High-rise Buildings

    Directory of Open Access Journals (Sweden)

    Guanghua Zong

    2008-11-01

    Full Text Available A new kind of pneumatic climbing robot is presented to meet the requirements of glass-wall cleaning for high-rise buildings, which is totally actuated by pneumatic cylinders and attached to the glass wall with vacuum suckers. Using the pneumatic actuators the climbing robot can be made lightweight and dexterous. At the same time the movement driven by pneumatic actuators has the characteristic of passive compliance. In order to solve the problems of high speed movement for the Y cylinder and precise position control of the X cylinder, the applied pneumatic schemes of X and Y cylinders are employed to drive the high-speed on-off solenoid valves and an ordinary valve to adjust the air-flow and pressure to the cylinders. Furthermore a method of segment and variable bang-bang controller is proposed to implement the accurate control of the position servo system for the X cylinder during the sideways movement. Testing results show that the novel approach can effectively improve the control quality. This cleaning robot can meet the requirements of realization.

  3. Effective Pneumatic Scheme and Control Strategy of a Climbing Robot for Class Wall Cleaning on High-rise Buildings

    Directory of Open Access Journals (Sweden)

    Houxiang Zhang

    2006-06-01

    Full Text Available A new kind of pneumatic climbing robot is presented to meet the requirements of glass-wall cleaning for high-rise buildings, which is totally actuated by pneumatic cylinders and attached to the glass wall with vacuum suckers. Using the pneumatic actuators the climbing robot can be made lightweight and dexterous. At the same time the movement driven by pneumatic actuators has the characteristic of passive compliance. In order to solve the problems of high speed movement for the Y cylinder and precise position control of the X cylinder, the applied pneumatic schemes of X and Y cylinders are employed to drive the high-speed on-off solenoid valves and an ordinary valve to adjust the air-flow and pressure to the cylinders. Furthermore a method of segment and variable bang-bang controller is proposed to implement the accurate control of the position servo system for the X cylinder during the sideways movement. Testing results show that the novel approach can effectively improve the control quality. This cleaning robot can meet the requirements of realization.

  4. US-China Clean Energy Research Center on Building Energy Efficiency: Materials that Improve the Cost-Effectiveness of Air Barrier Systems

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-12-01

    The US–China Clean Energy Research Center (CERC) was launched in 2009 by US Energy Secretary Steven Chu, Chinese Minister of Science and Technology Wan Gang, and Chinese National Energy Agency Administrator Zhang Guobao. This 5-year collaboration emerged from the fact that the United States and China are the world’s largest energy producers, energy consumers, and greenhouse gas emitters, and that their joint effort could have significant positive repercussions worldwide. CERC’s main goal is to develop and deploy clean energy technologies that will help both countries meet energy and climate challenges. Three consortia were established to address the most pressing energy-related research areas: Advanced Coal Technology, Clean Vehicles, and Building Energy Efficiency (BEE). The project discussed in this report was part of the CERC-BEE consortia; its objective was to lower energy use in buildings by developing and evaluating technologies that improve the cost-effectiveness of air barrier systems for building envelopes.

  5. Effect of Air Cleaning Technologies in Conjunction With the Use of Rotary Heat Exchangers in Residential Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Bergsøe, Niels Christian; Ekberg, Lars

    2013-01-01

    This study is part of a research project concerning the possibilities of applying efficient air cleaning technologies using rotary heat exchanger in residential buildings. The purpose of this project was to identify and adapt new air-cleaning technologies for implementation in HVAC systems...... with rotary air-to-air heat exchangers. For this purpose, a mechanical filter with low pressure drop and a 4 cm thick activated carbon filter were selected for testing in a laboratory environment. The measurements included testing of the filters, separately and combined, in a ductwork to study the efficiency...

  6. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  7. Correlating Cleaning Thoroughness with Effectiveness and Briefly Intervening to Affect Cleaning Outcomes: How Clean Is Cleaned?

    Directory of Open Access Journals (Sweden)

    Robert Clifford

    Full Text Available The most efficient approach to monitoring and improving cleaning outcomes remains unresolved. We sought to extend the findings of a previous study by determining whether cleaning thoroughness (dye removal correlates with cleaning efficacy (absence of molecular or cultivable biomaterial and whether one brief educational intervention improves cleaning outcomes.Before-after trial.Newly built community hospital.90 minute training refresher with surface-specific performance results.Dye removal, measured by fluorescence, and biomaterial removal and acquisition, measured with culture and culture-independent PCR-based assays, were clandestinely assessed for eight consecutive months. At this midpoint, results were presented to the cleaning staff (intervention and assessments continued for another eight consecutive months.1273 surfaces were sampled before and after terminal room cleaning. In the short-term, dye removal increased from 40.3% to 50.0% (not significant. For the entire study period, dye removal also improved but not significantly. After the intervention, the number of rooms testing positive for specific pathogenic species by culturing decreased from 55.6% to 36.6% (not significant, and those testing positive by PCR fell from 80.6% to 53.7% (P = 0.016. For nonspecific biomaterial on surfaces: a removal of cultivable Gram-negatives (GN trended toward improvement (P = 0.056; b removal of any cultivable growth was unchanged but acquisition (detection of biomaterial on post-cleaned surfaces that were contaminant-free before cleaning worsened (P = 0.017; c removal of PCR-based detection of bacterial DNA improved (P = 0.046, but acquisition worsened (P = 0.003; d cleaning thoroughness and efficacy were not correlated.At this facility, a minor intervention or minimally more aggressive cleaning may reduce pathogen-specific contamination, but not without unintended consequences.

  8. Promoting energy efficient building in China through clean development mechanism

    International Nuclear Information System (INIS)

    Zhou, Lu; Li, Jing; Chiang, Yat Hung

    2013-01-01

    This study aims to investigate the barriers which impede the promotion of Energy Efficient Building (EEB), and to propose solutions to alleviate these barriers by capturing the benefits from Clean Development Mechanism (CDM), in the context of China. Through comprehensive literature review, eight types of significant barriers are identified, including weak enforcement of government policies, market inefficiency, information barrier, small and scattering buildings, fragmentation of the construction industry, perceived high risk, higher initial cost, and difficulty in energy management. To overcome the barriers, the potential of CDM to facilitate EEB promotion is then discussed. These barriers are verified and potential solutions are tested with a questionnaire survey conducted among five professional groups in China, i.e. designers, project managers, quantity surveyors, marketing managers and property managers. The results suggest that they generally identified with the barriers. However, their limited awareness of CDM implies that corresponding policies should be formulated and implemented to improve their capability of providing more EEBs with CDM. - Highlights: ► Eight types of significant barriers to the implement of EEB are identified. ► The sources and roots of barriers are verified with the industry professionals. ► Benefits of CDM to EEB are discussed. ► There is limited awareness of CDM in building sector. ► Overcoming or alleviating these barriers through CDM and other sources are proposed

  9. Ecological effectiveness of oil spill countermeasures: how clean is clean?

    International Nuclear Information System (INIS)

    Baker, J.M.

    1999-01-01

    This paper with 94 references examines background levels of hydrocarbons and the difficulty of defining clean. Processes and timescales for natural cleaning, and factors affecting natural cleaning timescales are considered. Ecological advantages and disadvantages of clean-up methods are highlighted, and five case histories of oil spills are summarised. The relationships between ecological and socio-economic considerations, and the need for a net environmental benefit analysis which takes into account the advantages and disadvantages of clean-up responses and natural clean-up are discussed. A decision tree for evaluating the requirement for shore clean-up is illustrated. (UK)

  10. Is the use of particle air filtration justified? Costs and benefits of filtration with regard to health effects, building cleaning and occupant productivity

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Clausen, Geo; Weschler, Charles J.

    2008-01-01

    Estimates of costs and the corresponding benefits of particle filtration have been derived for a standard office building. Reduction in occupants’ exposure to particles during their workday is anticipated to reduce their morbidity and mortality. Filtration may also reduce the costs associated......, the sensitivity of the results to these parameters was evaluated as part of this study. The study also acknowledges that the benefits-to-costs ratio depends on the perspective of the stakeholder: the employer renting the building is impacted by occupant performance and building energy costs; the building owner...... is impacted by maintenance of the building and its HVAC system; society is impacted by the employees’ health and welfare. Regardless of perspective, particle filtration is anticipated to lead to annual savings significantly exceeding the running costs for filtration. However, economic losses resulting from...

  11. CPV performance versus soiling effects: Cleaning policies

    Science.gov (United States)

    Sanchez, D.; Trujillo, P.; Martinez, M.; Ferrer, J. P.; Rubio, F.

    2012-10-01

    In order to improve the performance of the CPV Plants in a cost effective way it is important to define the best cleaning policies, analyzing the effect of soiling in the surface of CPV modules. The energy generation of a CPV technology based in Fresnel Lens improves up to 7% when the surface of the module is cleaned. Some experimental measurements have been carried out over CPV modules and a model has been defined to analyze what is the best cleaning policy for that Technology in Puertollano. The power losses because of soiling and the critical time until the power losses stabilizes are obtained from the measurements; they are used as an input for the simulation. Using an established cleaning cost and the feeding tariff from Spain in 2007 it has been obtained that cleaning only reports a profit during the summer. The conclusion of the work is that the cleaning tasks have to be carefully planned together with the meteorological forecast in order to maximize the investment made in the cleaning.

  12. [Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].

    Science.gov (United States)

    Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun

    2016-01-01

    To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.

  13. Intelligent Sensor for Autonomous Cleaning in livestock buildings (ISAC) - A challenge in bioenvironmental engineering

    DEFF Research Database (Denmark)

    Strøm, J.S.; Zhang, G.; Blanke, Mogens

    2003-01-01

    Manual cleaning of livestock buildings, using high-pressure water technology, is one of the most tedious and health threatening tasks which is conducted by human labour. The cleaning process itself contributes to deterioration of the working environment due to stirring up dirt, microorganisms...

  14. Clean Cities: Building Partnerships to Cut Petroleum Use in Transportation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-01-07

    This brochure provides an overview of the U.S. Department of Energy's (DOE's) Clean Cities program, which advances the nation's economic, environmental, and energy security by supporting local actions to cut petroleum use in transportation. At the national level, the program develops and promotes publications, tools, and other unique resources. At the local level, nearly 100 coalitions leverage these resources to create networks of stakeholders.

  15. Clean Cities: Building Partnerships to Cut Petroleum Use in Transportation

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-01

    This brochure provides an overview of the U.S. Department of Energy's (DOE's) Clean Cities program, which advances the nation's economic, environmental, and energy security by supporting local actions to cut petroleum use in transportation. At the national level, the program develops and promotes publications, tools, and other unique resources. At the local level, nearly 100 coalitions leverage these resources to create networks of stakeholders.

  16. Efficient methods of nanoimprint stamp cleaning based on imprint self-cleaning effect

    Energy Technology Data Exchange (ETDEWEB)

    Meng Fantao; Chu Jinkui [Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, 116024 Dalian (China); Luo Gang; Zhou Ye; Carlberg, Patrick; Heidari, Babak [Obducat AB, SE-20125 Malmoe (Sweden); Maximov, Ivan; Montelius, Lars; Xu, H Q [Division of Solid State Physics, Lund University, Box 118, S-22100 Lund (Sweden); Nilsson, Lars, E-mail: ivan.maximov@ftf.lth.se [Department of Food Technology, Engineering and Nutrition, Lund University, Box 117, S-22100 Lund (Sweden)

    2011-05-06

    Nanoimprint lithography (NIL) is a nonconventional lithographic technique that promises low-cost, high-throughput patterning of structures with sub-10 nm resolution. Contamination of nanoimprint stamps is one of the key obstacles to industrialize the NIL technology. Here, we report two efficient approaches for removal of typical contamination of particles and residual resist from stamps: thermal and ultraviolet (UV) imprinting cleaning-both based on the self-cleaning effect of imprinting process. The contaminated stamps were imprinted onto polymer substrates and after demolding, they were treated with an organic solvent. The images of the stamp before and after the cleaning processes show that the two cleaning approaches can effectively remove contamination from stamps without destroying the stamp structures. The contact angles of the stamp before and after the cleaning processes indicate that the cleaning methods do not significantly degrade the anti-sticking layer. The cleaning processes reported in this work could also be used for substrate cleaning.

  17. Experimental study on air cleaning effect of clean air heat pump and its impact on ventilation requirement

    DEFF Research Database (Denmark)

    Fang, Lei; Sheng, Ying; Nie, Jinzhe

    2017-01-01

    This study investigated air purification effect of a Clean-Air Heat Pump (CAHP) which combined a desiccant wheel with a heat pump for both air cleaning and HVAC of buildings. The experiment was conducted in a field lab at four different outdoor air supply rates with and without air cleaning by CAHP....... Both sensory assessments of perceived air quality and chemical measurements of TVOC concentrations were conducted for evaluating the air cleaning performance of the CAHP. The results of experiment showed that running the CAHP improved significantly perceived air quality. At 2 L/s per person of outdoor...... air supply rate with operating the CAHP, the air quality was equivalent to the value at the higher outdoor air supply rate of 10 L/s per person without running CAHP. The TVOC measurements observed over 92% of efficiency on removal of indoor air VOCs and no VOCs accumulation on the desiccant wheel...

  18. Measuring cavitation and its cleaning effect

    NARCIS (Netherlands)

    Verhaagen, B.; Fernandez Rivas, David

    2016-01-01

    The advantages and limitations of techniques for measuring the presence and amount of cavitation, and for quantifying the removal of contaminants, are provided. After reviewing chemical, physical, and biological studies, a universal cause for the cleaning effects of bubbles cannot yet be concluded.

  19. Demand for Clean Energies Efficient Development in Buildings Technologies

    International Nuclear Information System (INIS)

    Mustafa Omer, Abdeen

    2017-01-01

    Aims/Purpose: The increased availability of reliable and efficient energy services stimulates new development alternatives. This article discusses the potential for such integrated systems in the stationary and portable power market in response to the critical need for a cleaner energy technology. Throughout the theme several issues relating to renewable energies, environment, and sustainable development are examined from both current and future perspectives. It is concluded that green energies like wind, solar, ground source heat pumps, and biomass must be promoted, implemented, and demonstrated from the economic and/or environmental point view. Biogas from biomass appears to have potential as an alternative energy source, which is potentially rich in biomass resources. This is an overview of some salient points and perspectives of biogas technology. The current literature is reviewed regarding the ecological, social, cultural and economic impacts of biogas technology. This article gives an overview of present and future use of biomass as an industrial feedstock for production of fuels, chemicals and other materials. However, to be truly competitive in an open market situation, higher value products are required. Results suggest that biogas technology must be encouraged, promoted, invested, implemented, and demonstrated, but especially in remote rural areas. Study design: Anticipated patterns of future energy use and consequent environmental impacts (acid precipitation, ozone depletion and the greenhouse effect or global warming) are comprehensively discussed in this article. Place and Duration of Study: National Centre for Research, Energy Research Institute (ERI), between January 2014 and July 2015. (author)

  20. Cleaning, abrasion, and polishing effect of novel perlite toothpaste abrasive.

    Science.gov (United States)

    Wang, Bo

    2013-01-01

    This study was intended to optimize perlite particle size and morphology for better tooth cleaning and lower tooth abrasion, and to evaluate the performance of a whitening toothpaste containing the optimized perlite abrasive for tooth cleaning, abrasion, and polishing. Perlite toothpaste abrasive samples were prepared by air classifying a commercial expanded perlite product. The tooth cleaning and abrasion properties for these classified perlite samples were reported via the pellicle cleaning ratio (PCR) and relative dentin abrasion (RDA). Performance of the whitening toothpaste containing the optimized perlite abrasive in tooth cleaning, polishing, and abrasion was evaluated against a widely used synthetic high-cleaning silica. Air classification removes large perlite particles and also physically changes perlite particle morphology from mostly three dimensional and angular particles to mainly two dimensional and platy particles. All the classified samples show good tooth cleaning effect, but tooth abrasion decreases significantly with decreasing particle size. Compared to high-cleaning silica whitening toothpaste, the whitening toothpaste containing the optimized perlite abrasive (PerlClean) is slightly better at tooth cleaning, lower in tooth abrasion, and significantly better at tooth polishing. Fine platy perlite particles are effective in tooth cleaning with low tooth abrasion. The enhanced performance of optimized perlite toothpaste abrasive compared to high-cleaning silica in a whitening toothpaste is attributed to the optimized particle size distribution and the unique platy particle geometry.

  1. Conditions for the clean slate effect after success or failure.

    Science.gov (United States)

    Körner, Anita; Strack, Fritz

    2018-03-20

    The act of physically cleaning one's hands may reduce the impact of past experiences, termed clean-slate effect. Cleaning was found to affect negative, neutral, and mildly positive states. We extend this influence to success, a self-serving state. We manipulated success vs. failure and measured changes in optimism (Experiment 1) or self-esteem (Experiment 2). Moreover, we examined boundary conditions for the clean-slate effect. Experiment 1 indicates that the influence of performance on optimism diminishes if participants knew (compared to did not know) they were cleaning their hands. Experiment 2 indicates that the influence of performance on self-esteem diminishes if participants cleaned themselves (compared to an object). These results suggest that the clean-slate effect requires both awareness and self-reference of the cleaning act. Thus, the clean-slate effect seems to depend on both conscious inferences and automatic processes. A meta-analysis across the experiments confirms a moderate-sized clean-slate effect.

  2. Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009 - June 30, 2010

    Energy Technology Data Exchange (ETDEWEB)

    Finch, P.; Potes, A.

    2010-06-01

    In June 2009, the State of Hawaii enacted an Energy Efficiency Portfolio Standard (EEPS) with a target of 4,300 gigawatt hours (GWh) by 2030 (Hawaii 2009). Upon setting this goal, the Hawaii Clean Energy Initiative, Booz Allen Hamilton (BAH), and the National Renewable Energy Laboratory (NREL), working with select local stakeholders, partnered to execute the first key step toward attaining the EEPS goal: the creation of a high-resolution roadmap outlining key areas of potential electricity savings. This roadmap was divided into two core elements: savings from new construction and savings from existing buildings. BAH focused primarily on the existing building analysis, while NREL focused on new construction forecasting. This report presents the results of the Booz Allen Hamilton study on the existing building stock of Hawaii, along with conclusions on the key drivers of potential energy efficiency savings and on the steps necessary to attain them.

  3. TiO2-SiO2 Coatings with a Low Content of AuNPs for Producing Self-Cleaning Building Materials

    Directory of Open Access Journals (Sweden)

    Manuel Luna

    2018-03-01

    Full Text Available The high pollution levels in our cities are producing a significant increase of dust on buildings. An application of photoactive coatings on building materials can produce buildings with self-cleaning surfaces. In this study, we have developed a simple sol-gel route for producing Au-TiO2/SiO2 photocatalysts with application on buildings. The gold nanoparticles (AuNPs improved the TiO2 photoactivity under solar radiation because they promoted absorption in the visible range. We varied the content of AuNPs in the sols under study, in order to investigate their effect on self-cleaning properties. The sols obtained were sprayed on a common building stone, producing coatings which adhere firmly to the stone and preserve their aesthetic qualities. We studied the decolourization efficiency of the photocatalysts under study against methylene blue and against soot (a real staining agent for buildings. Finally, we established that the coating with an intermediate Au content presented the best self-cleaning performance, due to the role played by its structure and texture on its photoactivity.

  4. Effect of cleaning products on upholstery leather finishes

    OpenAIRE

    Lara López, Mercedes

    2003-01-01

    The main objective of the project is to investigate the effects of cleaning products on upholstery leather finishes. Focusing on products applicable to upholstery leather cleaning, non-typical leather cleaners (and possible contaminants) or ink removers, in order to find out their behaviour, understanding how they work and if they are suitable for their purpose. Moreover an initial investigation about mechanism of soiling is proposed, in order, in the future, to avoid the soiling or develop a...

  5. The environmental effect of subsidies for clean technologies

    International Nuclear Information System (INIS)

    De Vries, F.P.; Nentjes, A.

    2001-01-01

    Environmental subsidies for clean technology result in a larger diffusion of such technology. However, as a result emissions can increase in imperfect markets for products. When several companies compete each other with clean and dirty technologies, production and emission will rise because of price competition.This effect will be even larger in case subsidies are applied. Therefore, subsidies are not advisable for every market. In this article an evolutionary game theory has been used with respect to the diffusion of environment-friendly innovation of products and the role of environmental policy instruments (in particular subsidies). 7 refs

  6. Effect of Time in Chemical Cleaning of Ultrafiltration Membranes

    NARCIS (Netherlands)

    Levitsky, I.; Naim, R.; Duek, A.; Gitis, V.

    2012-01-01

    Chemical cleaning of ultrafiltration membranes is often considered successful when the flux through a cleaned membrane is much higher than through a pristine one. Here, a novel definition of cleaning intensity is proposed as the product of the concentration of the cleaning agent and the cleaning

  7. Development of weightage for criteria affecting in retrofitting of existing building in Higher Learning Institution with clean energy initiatives

    Science.gov (United States)

    Izie Adiana Abidin, Nur; Aminuddin, Eeydzah; Zakaria, Rozana; Mazzuana Shamsuddin, Siti; Sahamir, Shaza Rina; Shahzaib, Jam; Nafis Abas, Darul

    2018-04-01

    Campus university building is the Higher Learning Institution (HLI) involves complex activities and operations, conserving the energy has become paramount important. There are several efforts taken by universities to improve its current energy use such as policy development, education, and adaption of energy conservation solution through retrofitting. This paper aims to highlight the importance of the criteria affecting in retrofitting of existing buildings with clean energy in order to achieve zero energy balance in buildings. The focus is given to the development of criteria for solar photovoltaic (solar PV), wind turbines and small-scale hydropower. A questionnaire survey was employed and distributed to the green building expert practitioner. Factor Analysis, Factor Score, and Weightage Factor were adapted as a method of analysis in order to produce the final result with weightage output for prioritization and ranking of the relevant criteria. The result performed assists to provide the stakeholders an overview of the important criteria that should be considered especially during the decision making to retrofit the existing buildings with clean energy resources. The criteria developed are also to establish a structured decision-making process and to ensure the selection of the decision or alternatives achieve the desired outcome.

  8. Using the CLEAN educational resource collection for building three-dimensional lessons to teach the climate system

    Science.gov (United States)

    Gold, A. U.; Sullivan, S. M.; Manning, C. L. B.; Ledley, T. S.; Youngman, E.; Taylor, J.; Niepold, F., III; Kirk, K.; Lockwood, J.; Bruckner, M. Z.; Fox, S.

    2017-12-01

    The impacts of climate change are a critical societal challenge of the 21st century. Educating students about the globally connected climate system is key in supporting the development of mitigation and adaptation strategies. Systems thinking is required for students to understand the complex, dynamic climate systems and the role that humans play within them. The interdisciplinary nature of climate science challenges educators, who often don't have formal training in climate science, to identify resources that are scientifically accurate before weaving them together into units that teach about the climate system. The Climate Literacy and Energy Awareness Network (CLEAN) supports this work by providing over 700 peer-reviewed, classroom-ready resources on climate and energy topics. The resource collection itself provide only limited instructional guidance, so educators need to weave the resources together to build multi-dimensional lessons that develop systems thinking skills. The Next Generation Science Standards (NGSS) science standards encourage educators to teach science in a 3-dimensional approach that trains students in systems thinking. The CLEAN project strives to help educators design NGSS-style, three-dimensional lessons about the climate system. Two approaches are currently being modeled on the CLEAN web portal. The first is described in the CLEAN NGSS "Get Started Guide" which follows a step-by-step process starting with the Disciplinary Core Idea and then interweaves the Cross-Cutting Concepts (CCC) and the Science and Engineering Practices (SEP) based on the teaching strategy chosen for the lesson or unit topic. The second model uses a climate topic as a starting place and the SEP as the guide through a four-step lesson sequence called "Earth Systems Investigations". Both models use CLEAN reviewed lessons as the core activity but provide the necessary framework for classroom implementation. Sample lessons that were developed following these two

  9. Effectiveness of aged graffiti cleaning on granite by chemical and mechanical procedures

    Science.gov (United States)

    Gomes, Vera; Dionísio, Amélia; Santiago Pozo-Antonio, José

    2017-04-01

    Granite is one of the most common building stones in the European Cultural Heritage mainly in Northwest Iberian Peninsula. Nowadays, graffiti when a result of an act of vandalism is one of the most important threat, involving a serious risk to heritage sustainability. The cleaning is expensive and in most of the cases, the complete removal is not achieved. Many cities worldwide spend huge amounts of money in cleaning campaigns and European Commission started to create urban environment policies to prevent and eliminate graffiti and also finance projects to develop new cleaning procedures and antigraffiti coatings1,2. However, in many cases graffiti is applied in monuments and façades without antigraffiti and in real practice, they are only cleaned after being long exposure to the atmosphere, reaction with the environment (rain and atmospheric pollutants) and also with the substrate, leading changes in their physical and chemical properties. However, no scientific studies focused on graffiti aging were found and also on the influence of the aging on the cleaning effectiveness, which is always evaluated with fresh graffiti. Therefore, the need to optimize the cleaning of aged graffiti is urgent. This paper aims to study the influence of the exposition of graffiti paintings to one of the most important urban contaminant SO2 on the cleaning effectiveness of graffiti on the valuable ornamental granite Rosa Porriño. Two different chemical products and two different mechanical procedures based on low pressure projection (wet and dry) were evaluated. Four different colour graffiti paintings (red, black, blue and silver) with different compositions were tested. The criteria for assessing the global cleaning effectiveness was considering the graffiti extraction and also the damage induced on the substrate through changes in the chromatic parameters, static contact angle and surface roughness of the stones, identification of deleterious products and modification of the

  10. Effects of beach cast cleaning on beach quality, microbial food web, and littoral macrofaunal biodiversity

    Science.gov (United States)

    Malm, Torleif; Råberg, Sonja; Fell, Sabine; Carlsson, Per

    2004-06-01

    At the end of the summer, drifting filamentous red algae cover shallow bottoms and accumulate in huge cast walls on the open shores of the non-tidal central Baltic Sea. The hypotheses that beach cleaning increases water clarity, decreases the organic content of the sand, and increases the species diversity in the shallow zone closest to the shore, were tested through field investigations and experiments. Cleaned shorelines were compared with un-cleaned shorelines at two sites with different intensity of beach cleaning in a rural area of SE Sweden. The results show that water clarity was significantly increased off the intensively cleaned beach but not off the moderately cleaned one. Similarly, the total leakage of nitrogenous compounds decreased off the intensively cleaned beach, but not off the moderately cleaned. The organic content of the sand was lower on both cleaned beaches compared with nearby un-cleaned beaches. The total animal biomass was significantly lower on the intensively cleaned beach compared with the un-cleaned beach, but the moderately cleaned beach gave no such effect. The difference in biodiversity and community structure between cleaned and un-cleaned beaches was insignificant. The most obvious difference in species composition was a much higher number of planktivore opossum shrimps of the genus Mysis and Praunus on the un-cleaned beaches. The bacterial production and the amount of ciliates larger than 20 mm were also higher on un-cleaned beaches, indicating that the microbial food web off the un-cleaned beaches is stimulated by the discharge of decomposing algal material. The conclusion of the study is that mechanical cleaning reduces the organic content of the beach sand and may change the water quality and microbial production, but the effect on the macrofaunal biodiversity is insignificant.

  11. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  12. BUILDING AN EFFECTIVE SALES FORCE

    Directory of Open Access Journals (Sweden)

    Ioana Olariu

    2016-06-01

    Full Text Available Building an effective sales force starts with selecting good salespeople, but good salespeople are very difficult to find. The reason for this is that most sales jobs are very demanding and require a great deal from the salesperson. There are many different types of sales jobs. Before it can hire salespeople, each company must do a careful job analysis to see what particular types of selling and other skills are necessary for each sales job. One task of the market planner is to establish clear objectives each year for the entire sales force, for each region, each sales office, and each salesperson. Sales jobs are different from in-house jobs in some significant ways. Nevertheless, each company must continually work on building and maintaining an effective sales force using the following steps: recruitment, selection, training, compensation and evaluation of each salesperson.

  13. Is the Clean Development Mechanism Effective for Emission Reductions?

    DEFF Research Database (Denmark)

    Tarp, Finn; Huang, Yongfu; He, Jingjing

    2014-01-01

    with great challenges, given the wide divide between developed and developing nations. Against this background, comprehensive evaluations of the effectiveness of Kyoto market‐based mechanisms such as the Clean Development Mechanism (CDM) in terms of mitigating human‐induced climate change are urgently needed...... reductions for 60 CDM host countries over the period 2005–2010, using a newly developed econometric method for dynamic panel data models associated with the X‐differencing procedure. Our results provide evidence in support of a decline in CO 2 emissions in CDM host countries. We conclude...

  14. Ontario's long-term energy plan, building our clean energy future

    International Nuclear Information System (INIS)

    2010-01-01

    The first energy priority of the plan is to provide all Ontarians with a clean, modern and reliable electricity system. It gives a summary of the means implemented to help families and businesses with increasing electricity costs. The plan is to shift the province from a coal-dependent system. Over the next 20 years, 15,000 MW (megawatt) of generating capacity will have to be rebuilt or constructed to replace older Ontario's energy infrastructures. In Ontario, an increase of about 3.5% per year in residential prices, resulting from the need to enjoy clean air, reliable generation and modernized transmission, is expected to occur over the next two decades. The expected electricity needs in Ontario and efficient means to satisfy them are described in this plan.

  15. Forward drive: the race to build the clean car of the future

    Energy Technology Data Exchange (ETDEWEB)

    Motavalli, Jim

    2001-10-15

    This comprehensive account of the past, present and future of the automobile examines the key trends, key technologies and key players involved in the race to develop clean, environmentally friendly vehicles that are affordable and that do not compromise on safety or design. Undertaking a rigorous interrogation of our global dependency on oil, the author demonstrates just how unwise and unnecessary this is in light of current developments such as the fuel cell revolution and the increasing viability of hybrid cars, which use both petrol and electricity - innovations that could signal a new era of clean, sustainable energy. The arguments put forward draw on support from an eclectic range of sources - including industry insiders, scientists, economists and environmentalists - to make for an enlightening read. (Author)

  16. Fluid dynamic effects on precision cleaning with supercritical fluids

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, M.R.; Hogan, M.O.; Silva, L.J.

    1994-06-01

    Pacific Northwest Laboratory staff have assembled a small supercritical fluids parts cleaning test stand to characterize how system dynamics affect the efficacy of precision cleaning with supercritical carbon dioxide. A soiled stainless steel coupon, loaded into a ``Berty`` autoclave, was used to investigate how changes in system turbulence and solvent temperature influenced the removal of test dopants. A pulsed laser beam through a fiber optic was used to investigate real-time contaminant removal. Test data show that cleaning efficiency is a function of system agitation, solvent density, and temperature. These data also show that high levels of cleaning efficiency can generally be achieved with high levels of system agitation at relatively low solvent densities and temperatures. Agitation levels, temperatures, and densities needed for optimal cleaning are largely contaminant dependent. Using proper system conditions, the levels of cleanliness achieved with supercritical carbon dioxide compare favorably with conventional precision cleaning methods. Additional research is currently being conducted to generalize the relationship between cleaning performance and parameters such as contaminant solubilities, mass transfer rates, and solvent agitation. These correlations can be used to optimize cleaning performance, system design, and time and energy consumption for particular parts cleaning applications.

  17. Green, Clean, & Mean: Pushing the Energy Envelope in Tech Industry Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Granderson, Jessica [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Rengie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Diamond, Richard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Haves, Philip [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Nordman, Bruce [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathew, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piette, Mary Ann [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Robinson, Gerald [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Selkowitz, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-05-01

    When it comes to innovation in energy and building performance, one can expect leading-edge activity from the technology sector. As front-line innovators in design, materials science, and information management, developing and operating high-performance buildings is a natural extension of their core business. The energy choices made by technology companies have broad importance given their influence on society at large as well as the extent of their own energy footprint. Microsoft, for example, has approximately 250 facilities around the world (30 million square feet of floor area), with significant aggregate energy use of approximately 4 million kilowatt-hours per day (Figure 1).

  18. Radiation Resistant Hybrid Lotus Effect Photoelectrocatalytic Self-Cleaning Anti-Contamination Coatings, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop radiation resistant hybrid Lotus Effect photoelectrocatalytic self-cleaning anti-contamination coatings for application to Lunar...

  19. Radioactive air emissions notice of construction 340-A building tank sludge clean out

    International Nuclear Information System (INIS)

    Hays, C.B.

    1997-01-01

    This document serves as a notice of construction pursuant to the requirements of Washington Administrative Code (WAC) 246-247-060 and as a request for approval to construct pursuant to 40 Code of Federal Regulations (CFR) 61.96 for the removal of sludge from six storage tanks located inside the 340-A Building, which is located in the 300 Area of the Hanford Site

  20. Methods for air cleaning and protection of building occupants from airborne pathogens

    Energy Technology Data Exchange (ETDEWEB)

    Bolashikov, Z.D.; Melikov, A.K. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Nils Koppels Alle, building 402, 2800 Lyngby (Denmark)

    2009-07-15

    This article aims to draw the attention of the scientific community towards the elevated risks of airborne transmission of diseases and the associated risks of epidemics or pandemics. The complexity of the problem and the need for multidisciplinary research is highlighted. The airborne route of transmission, i.e. the generation of pathogen laden droplets originating in the respiratory tract of an infected individual, the survivability of the pathogens, their dispersal indoors and their transfer to a healthy person are reviewed. The advantages and the drawbacks of air dilution, filtration, ultraviolet germicidal irradiation (UVGI), photocatalytic oxidation (PCO), plasmacluster ions and other technologies for air disinfection and purification from pathogens are analyzed with respect to currently used air distribution principles. The importance of indoor air characteristics, such as temperature, relative humidity and velocity for the efficiency of each method is analyzed, taking into consideration the nature of the pathogens themselves. The applicability of the cleaning methods to the different types of total volume air distribution used at present indoors, i.e. mixing, displacement and underfloor ventilation, as well as advanced air distribution techniques (such as personalized ventilation) is discussed. (author)

  1. Laser cleaning of parchment: structural, thermal and biochemical studies into the effect of wavelength and fluence

    International Nuclear Information System (INIS)

    Kennedy, Craig J.; Vest, Marie; Cooper, Martin; Wess, Tim J.

    2004-01-01

    Laser cleaning of parchment is a novel technique that has the potential to provide contactless, chemical-free cleaning of historically important documents. However, the effect of laser cleaning on the collagenous structure of parchment is still poorly understood, as is the effect of the wavelength or the energy density (fluence level) used to clean parchment. In this study, small angle X-ray scattering (SAXS), shrinkage temperature (Ts) measurements by the micro hot table technique and SDS-polyacrylamide gel electrophoresis (SDS-PAGE) of parchment samples after laser cleaning reveal the effect of cleaning to the structural, thermal and molecular characteristics of parchment, respectively. The effect of cleaning at infrared (1064 nm), green (532 nm) and ultraviolet (266 nm) wavelengths at a range of fluence levels is investigated. SAXS is used to investigate the removal of dirt from parchment. Laser cleaning at IR or green wavelengths appears not to alter the collagen diffraction pattern from SAXS, the shrinkage activity or shrinkage temperature from Ts measurements or the molecular integrity of parchment as shown by SDS-PAGE. However, parchments cleaned at the ultraviolet wavelength display structural damage and a reduction in hydrothermal stability and molecular integrity

  2. Bacterial contamination of stethoscope chest pieces and the effect of daily cleaning.

    Science.gov (United States)

    Fujita, H; Hansen, B; Hanel, R

    2013-01-01

    Stethoscopes are a potential source of nosocomial infection for hospitalized humans, a phenomenon not previously studied in companion animals. To determine if daily cleaning of stethoscope chest pieces reduces bacterial contamination between cleanings. Client-owned dogs and cats. Prospective observational study. In phase 1, bacterial cultures were obtained from the chest pieces of 10 participant stethoscopes once weekly for 3 weeks. In phase 2, stethoscopes were cleaned daily and 2 culture samples were obtained once weekly, immediately before and after cleaning with 70% isopropyl alcohol, for 3 weeks. Daily cleaning eliminated bacteria immediately after each cleaning (P = .004), but did not reduce the rate of positive cultures obtained before cleaning in phase 2. Cultures were positive for 20/30 (67%) samples during phase 1 and 18/30 (60%) obtained before daily cleaning during phase 2. Recovered organisms included normal skin flora, agents of opportunistic infections, and potential pathogens. The only genus that was repeatedly recovered from the same stethoscope for 2 or more consecutive weeks was Bacillus sp. Daily cleaning was highly effective at removing bacteria, but provided no reduction in precleaning contamination. Cleaning stethoscopes after use on dogs or cats infected with pathogenic bacteria and before use on immunocompromised animals should be considered. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  3. Investigation of a cable-driven parallel mechanism for interaction with a variety of surface, applied to the cleaning of free-form buildings

    NARCIS (Netherlands)

    Voss, K.H.J.; van der Wijk, V.; Herder, Justus Laurens; Lenarcic, Jadran; Husty, Manfred

    2012-01-01

    In this paper, the capability of a specific cable-driven parallel mechanism to interact with a variety of surfaces is investigated. This capability could be of use in for example the cleaning of large building surfaces. A method is presented to investigate the workspace for which the cables do not

  4. Cleaning and sanitation in the design and management of buildings. Counselling part no 5; Renhold og hygiene ved planlegging, utforming og drift av bygg. Veiledningshefte nr.5

    Energy Technology Data Exchange (ETDEWEB)

    Dahl, Paal Anders; Nilsen, Steinar K.; Sjoevold, Oddbjoern

    1999-02-01

    The report series ''Cleaning and sanitation in the design and management of buildings'' consists of twelve reports containing professional advice. The present report discusses the design of ventilation rooms and ventilation systems, heating- and electricity systems, sanitary installation, shafts etc., and directions on constructional matters. Legal aspects are also dealt with.

  5. The Effect of Selected Cleaning Techniques on Berkshire Lee Marble: A Scientific Study at Philadelphia City Hall

    Science.gov (United States)

    Mossotti, Victor G.; Eldeeb, A. Raouf; Fries, Terry L.; Coombs, Mary Jane; Naude, Virginia N.; Soderberg, Lisa; Wheeler, George S.

    2002-01-01

    This report describes a scientific investigation of the effects of eight different cleaning techniques on the Berkshire Lee marble component of the facade of the East Center Pavilion at Philadelphia City Hall; the study was commissioned by the city of Philadelphia. The eight cleaning techniques evaluated in this study were power wash (proprietary gel detergent followed by water rinse under pressure), misting (treatment with potable, nebulized water for 24-36 hours), gommage (proprietary Thomann-Hanry low-pressure, air-driven, small-particle, dry abrasion), combination (gommage followed by misting), Armax (sodium bicarbonate delivered under pressure in a water wash), JOS (dolomite powder delivered in a low-pressure, rotary-vortex water wash), laser (thermal ablation), and dry ice (powdered-dry-ice abrasion delivered under pressure). In our study approximately 160 cores were removed from the building for laboratory analysis. We developed a computer program to analyze scanning-electron-micrograph images for the microscale surface roughness and other morphologic parameters of the stone surface, including the near-surface fracture density of the stone. An analysis of more than 1,100 samples cut from the cores provided a statistical basis for crafting the essential elements of a reduced-form, mixed-kinetics conceptual model that represents the deterioration of calcareous stone in terms of self-organized soiling and erosion patterns. This model, in turn, provided a basis for identifying the variables that are affected by the cleaning techniques and for evaluating the extent to which such variables influence the stability of the stone. The model recognizes three classes of variables that may influence the soiling load on the stone, including such exogenous environmental variables as airborne moisture, pollutant concentrations, and local aerodynamics, and such endogenous stone variables as surface chemistry and microstructure (fracturing, roughness, and so on). This study

  6. Study on effective laser cleaning method to remove carbon layer from a gold surface

    International Nuclear Information System (INIS)

    Singh, Amol; Modi, Mohammed H; Lodha, G S; Choubey, A K; Upadhyaya, B N

    2013-01-01

    Hydrocarbon cracking and carbon contamination is a common problem in soft x-ray Synchrotron Radiation (SR) beamlines. Carbon contamination on optics is known to absorb and scatter radiation close to the C K-edge (284 eV) spectral region. The purpose of this work is to study and develop a laser cleaning method that can effectively remove the carbon contaminations without damaging the underneath gold-coated optics. The laser cleaning process is a non-contact, accurate, efficient and safe. Nd:YAG laser of 100 ns pulse duration is used for carbon cleaning. The effect of laser pulse duration, laser fluence, number of laser passes, angle of incidence and spot overlapping on the cleaning performance is studied. Cleaning effect and subsequent film quality after laser irradiation is analyzed using x-ray photoelectron spectroscopy (XPS) and soft x-ray reflectivity (SXR) techniques.

  7. Effectiveness of clean taxi priority incentive at Amsterdam Central Station

    NARCIS (Netherlands)

    van der Flier, A.S.; Dam, J.; van den Hoed, R.

    2017-01-01

    The municipality of Amsterdam wants to have an emission free taxi sector by 2025. In order to reach that goal, the city has taken a number of measures which favour clean taxis above conventional taxis. One of these measures is an innovative priority privilege scheme at the Amsterdam Central Station

  8. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    Science.gov (United States)

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  9. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    2013-04-01

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  10. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  11. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility

    Science.gov (United States)

    Santos-Junior, Aires G.; Ferreira, Adriano M.; Frota, Oleci P.; Rigotti, Marcelo A.; Barcelos, Larissa da S.; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G.; R. Furlan, Mara C.

    2018-01-01

    Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems. PMID:29643951

  12. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility.

    Science.gov (United States)

    Santos-Junior, Aires G; Ferreira, Adriano M; Frota, Oleci P; Rigotti, Marcelo A; Barcelos, Larissa da S; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G; R Furlan, Mara C

    2018-01-01

    Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle ( p =0.007) and the toilet bowl ( p =0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect ( p =0.04). The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.

  13. Effectiveness acidic pre-cleaning for copper-gold ore

    Directory of Open Access Journals (Sweden)

    Antonio Clareti Pereira

    Full Text Available Abstract The presence of copper-bearing minerals is known to bring on many challenges during the cyanidation of gold ore, like high consumption of cyanide and low extraction of metal, which are undesirable impacts on the auriferous recovery in the subsequent process step. The high copper solubility in cyanide prevents the direct use of classical hydrometallurgical processes for the extraction of gold by cyanidation. Additionally, the application of a conventional flotation process to extract copper is further complicated when it is oxidized. As a result, an acid pre-leaching process was applied in order to clean the ore of these copper minerals that are cyanide consumers. The objective was to evaluate the amount of soluble copper in cyanide before and after acidic cleaning. From a gold ore containing copper, the study selected four samples containing 0.22%, 0.55%, 1.00% and 1.36% of copper. For direct cyanidation of the ore without pre-treatment, copper extraction by cyanide complexing ranged from 8 to 83%. In contrast, the pre-treatment carried out with sulfuric acid extracted 24% to 99% of initial copper and subsequent cyanidation extracted 0.13 to 1.54% of initial copper. The study also showed that the copper contained in the secondary minerals is more easily extracted by cyanide (83%, being followed by the copper oxy-hydroxide minerals (60%, while the copper contained in the manganese oxide is less complexed by cyanide (8% a 12%. It was possible to observe that minerals with low acid solubility also have low solubility in cyanide. Cyanide consumption decreased by about 2.5 times and gold recovery increased to above 94% after acidic pre-cleaning.

  14. Monitoring and improving the effectiveness of surface cleaning and disinfection.

    Science.gov (United States)

    Rutala, William A; Weber, David J

    2016-05-02

    Disinfection of noncritical environmental surfaces and equipment is an essential component of an infection prevention program. Noncritical environmental surfaces and noncritical medical equipment surfaces may become contaminated with infectious agents and may contribute to cross-transmission by acquisition of transient hand carriage by health care personnel. Disinfection should render surfaces and equipment free of pathogens in sufficient numbers to prevent human disease (ie, hygienically clean). Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. CLEAN-AIR heat pump. Reduced energy consumption for ventilation in buildings by integrating air cleaning and heat pump. Final Report; CLEAN-AIR heat pump - Reduceret energiforbrug til ventilation af bygninger ved luftrensning integreret med luft varmepumpe. Slut rapport

    Energy Technology Data Exchange (ETDEWEB)

    Fang, L.; Olesen, Bjarne W.; Molinaro, G.; Simmonsen, P.; Skocajic, S. [Danmarks Tekniske Univ. Institut for Byggeri og Anlaeg, Lyngby (Denmark); Hummelshoej, R.M.; Carlassara, L. [COWI A/S, Lyngby, (Denmark); Groenbaek, H.; Hansen, Ole R. [Exhausto A/S, Langeskov (Denmark)

    2011-07-01

    This report summarizes task 1 of the Clean Air Heat Pump project - modelling and simulation on energy savings when using the clean air heat pump for ventilation, air cleaning and energy recovery. The total energy consumption of the proposed ventilation systems using clean air heat pump technology was calculated by a theoretical model and compared with the reference ventilation systems (conventional ventilation systems). The energy compared between the two systems includes energy used for heating, cooling and fan. The simulation and energy saving calculation was made for the application of the clean air heat pump in three typical climate conditions, i.e. mild-cold, mild-hot and hot and wet climates. Real climate data recorded from three cities in 2002 was used for the calculation. The three cities were Copenhagen (Denmark), Milan (Italy) and Colombo (Sir Lanka) which represent the above three typical climate zones. For the Danish climate (the mild cold climate), the calculations show that the ventilation system using clean air heat pump technology can save up to 42% of energy cost in winter compared to the conventional ventilation system. The energy saving in summer can be as high as 66% for the ventilation system with humidity control and 9% for the ventilation system without the requirement of humidity control. Since the Danish summer climate is very mild, over 80% of the yearly energy consumption for ventilation is used during winter season. It is, therefore, estimated that more than 35% annual energy saving for ventilation is expected in Denmark using the clean air heat pump ventilation technology. For the mild hot climate, e.g. the Italian climate, the calculations show that up to 63% of the energy saving can be achieved in summer season. For the winter mode, 17% reduction of the energy cost can be expected for the domestic use. For industrial use, the energy cost of the clean air heat pump may not be favourable due to the industrial price of gas in Italy is

  16. Protective effect of building against nuclear fallout

    International Nuclear Information System (INIS)

    Mueck, K.; Lovranich, E.; Steger, F.

    1995-02-01

    In order to adopt appropriate countermeasures to protect the public in case of a wide-spread contamination after a severe reactor accident, a profound knowledge of the dose to be expected and of the dose reduction to be expected if a specific countermeasure is adopted is required. Since external radiation contributes a major fraction of up to 80 % to the total dose, the interest is focused on the reduction of external dose by staying indoors. For this purpose measurements of the dose reduction by external radiation were performed in 40 residential rooms in Vienna which were chosen according to their fraction of the Viennese building structure. They were performed by measurement of the reduction of the gamma-flux in the interior of buildings compared to the gamma-flux outside. Measurements were carried out by a HPGe-detector which was positioned 1 m above ground. The observed dose reduction factors amounted to 0.013 on the average (protection factor 78.7 ± 49.7), with the protection factors of the investigated building types ranging from 6.5 (single house in garden) to 122.9 (edicifices of the turn of the century). The observed protection factors do not include the dose reduction by dense arrangement of buildings in urban areas which has to be considered separately. The dose reduction due to different radionuclide mixtures after severe reactor accidents was also investigated. Factors similar to that observed for Cs-137 were found. The maximum deviations amounted only 12 % and therefore may be neglected in the consideration of protective measures. Additional measurements were performed with the same detector shielded by lead on all sides to determine the contribution of the interior contamination. A contribution of between < 10 % to 50 % to the external dose in the interior of buildings was observed. Measures to reduce the inner contamination in rooms (closing of windows and doors, cleaning upon entering the building interior) in case of an event are therefore

  17. Effective cleaning of hexagonal boron nitride for graphene devices.

    Science.gov (United States)

    Garcia, Andrei G F; Neumann, Michael; Amet, François; Williams, James R; Watanabe, Kenji; Taniguchi, Takashi; Goldhaber-Gordon, David

    2012-09-12

    Hexagonal boron nitride (h-BN) films have attracted considerable interest as substrates for graphene. ( Dean, C. R. et al. Nat. Nanotechnol. 2010 , 5 , 722 - 6 ; Wang, H. et al. Electron Device Lett. 2011 , 32 , 1209 - 1211 ; Sanchez-Yamagishi, J. et al. Phys. Rev. Lett. 2012 , 108 , 1 - 5 .) We study the presence of organic contaminants introduced by standard lithography and substrate transfer processing on h-BN films exfoliated on silicon oxide substrates. Exposure to photoresist processing adds a large broad luminescence peak to the Raman spectrum of the h-BN flake. This signal persists through typical furnace annealing recipes (Ar/H(2)). A recipe that successfully removes organic contaminants and results in clean h-BN flakes involves treatment in Ar/O(2) at 500 °C.

  18. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    Science.gov (United States)

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  19. Performances in Tank Cleaning

    Directory of Open Access Journals (Sweden)

    Fanel-Viorel Panaitescu

    2018-03-01

    Full Text Available There are several operations which must do to maximize the performance of tank cleaning. The new advanced technologies in tank cleaning have raised the standards in marine areas. There are many ways to realise optimal cleaning efficiency for different tanks. The evaluation of tank cleaning options means to start with audit of operations: how many tanks require cleaning, are there obstructions in tanks (e.g. agitators, mixers, what residue needs to be removed, are cleaning agents required or is water sufficient, what methods can used for tank cleaning. After these steps, must be verify the results and ensure that the best cleaning values can be achieved in terms of accuracy and reliability. Technology advancements have made it easier to remove stubborn residues, shorten cleaning cycle times and achieve higher levels of automation. In this paper are presented the performances in tank cleaning in accordance with legislation in force. If tank cleaning technologies are effective, then operating costs are minimal.

  20. Review of cleaning techniques and their effects on the chemical composition of foliar samples

    Energy Technology Data Exchange (ETDEWEB)

    Rossini Oliva, S.; Raitio, H.

    2003-07-01

    Chemical foliar analysis is a tool widely used to study tree nutrition and to monitor the impact and extent of air pollutants. This paper reviews a number of cleaning methods, and the effects of cleaning on foliar chemistry. Cleaning may include mechanical techniques such as the use of dry or moistened tissues, shaking, blowing, and brushing, or use various washing techniques with water or other solvents. Owing to the diversity of plant species, tissue differences, etc., there is no standard procedure for all kinds of samples. Analysis of uncleaned leaves is considered a good method for assessing the degree of air contamination because it provides an estimate of the element content of the deposits on leaf surfaces or when the analysis is aimed at the investigation of transfer of elements along the food chain. Sample cleaning is recommended in order (1) to investigate the transfer rate of chemical elements from soil to plants, (2) to qualify the washoff of dry deposition from foliage and (3) to separate superficially absorbed and biomass-incorporated elements. Since there is not a standard cleaning procedure for all kinds of samples and aims, it is advised to conduct a pilot study in order to be able to establish a cleaning procedure to provide reliable foliar data. (orig.)

  1. Fouling research and cleaning effect by sponge ball on condencer tubes

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, S; Sano, A [Kansai Electric Power Co., Inc., Osaka (Japan); Minamoto, K; Mimura, K; Kyohara, S

    1978-07-01

    Systematic research has been performed to investigate the cleaning effect on condensers cooled by sea water. The test has been done for a year using the test condenser at the Kainan Power Station, Kansai Electric Power Company. The main purpose of this research was to see the effect of cleaning inner walls of condenser tubes with sponge balls on the prevention of adhesion of marine creatures such as barnacles and other shellfishes. As the test tubes, the aluminum-brass and titanium tubes with 25.4 mm diameter, 1.245 mm thickness and 170 mm length were used. Frequency of cleaning and flow rate were chosen as the variable parameters. The effect of seasons was also investigated. Major conclusions drawn from this research were as follows. (1) More adhesion of barnacles was observed at slower flow speed and in titanium tubes rather than aluminum brass tubes. (2) At the flow speed of 1 m/sec. cleaning frequency of more than twice a week was necessary to perfectly avoid the adhesion. (3) In summer, the adhesion was most intensive, whereas in winter, it was the least. (4) Barnacles were the most predominant organism. (5) Cleaning with sponge balls was effective.

  2. Fouling research and cleaning effect by sponge ball on condencer tubes

    International Nuclear Information System (INIS)

    Matsumoto, Seizo; Sano, Akira; Minamoto, Kenju; Mimura, Keisuke; Kyohara, Shigeru.

    1978-01-01

    Systematic research has been performed to investigate the cleaning effect on condensers cooled by sea water. The test has been done for a year using the test condenser at the Kainan Power Station, Kansai Electric Power Company. The main purpose of this research was to see the effect of cleaning inner walls of condenser tubes with sponge balls on the prevention of adhesion of marine creatures such as barnacles and other shellfishes. As the test tubes, the aluminum-brass and titanium tubes with 25.4 mm diameter, 1.245 mm thickness and 170 mm length were used. Frequency of cleaning and flow rate were chosen as the variable parameters. The effect of seasons was also investigated. Major conclusions drawn from this research were as follows. (1) More adhesion of barnacles was observed at slower flow speed and in titanium tubes rather than aluminum brass tubes. (2) At the flow speed of 1 m/sec. cleaning frequency of more than twice a week was necessary to perfectly avoid the adhesion. (3) In summer, the adhesion was most intensive, whereas in winter, it was the least. (4) Barnacles were the most predominant organism. (5) Cleaning with sponge balls was effective. (Aoki, K.)

  3. Development of a method to determine the effectiveness of cleaning agents in removal of biofilm derived spores in milking system

    Directory of Open Access Journals (Sweden)

    Ievgeniia Ostrov

    2016-09-01

    Full Text Available Microbial damages caused by biofilm forming bacteria in the dairy industry are a fundamental threat to safety and quality of dairy products. In order to ensure the optimal level of equipment hygiene in the dairy industry, it is necessary to determine the biofilm removal efficiency of cleaning agents used for cleaning-in-place procedures. However, currently there is no standard method available for evaluating and comparing cleaning agents for use in cleaning-in-place procedures in the dairy industry under realistic conditions. The present study aims to establish a cleaning-in-place model system to evaluate the effectiveness of cleaning agents in removal of biofilm derived spores from the surfaces of stainless steel which is the predominant substrate in milking equipment on dairy farms. The system is based on Bacillus subtilis spores surrounded with exopolymeric substances produced by bacteria during biofilm formation. The spores applied on sampling plates were mounted on T-junctions protruding 1.5 – 11-times the milk pipe diameter from the main loop to resemble different levels of cleaning difficulty. The cleaning tests were conducted using commercial alkaline detergents and caustic soda at conditions which are relevant to actual farm environment. The spores removal effect was evaluated by comparing the number of viable spores (attached to sampling plates before and after cleaning. Evaluation of the cleaning and disinfecting effect of cleaning agents towards biofilm derived spores was further performed, which indicates whether spores elimination effect of an agent is due to killing the spores or removing them from the surfaces of dairy equipment. Moreover, it was established that the presence of extracellular matrix is an important factor responsible for high level of cleaning difficulty characteristic for surface attached spores. In overall, the results of this study suggest that the developed model system simulates actual farm conditions for

  4. Joint China-United States Report for Year 1 Insulation Materials and Systems Project Area Clean Energy Research Center Building Energy Efficiency (CERC-BEE)

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, Therese K [ORNL; Biswas, Kaushik [ORNL; Song, Bo [China Academy of Building Research; Zhang, Sisi [China Academy of Building Research

    2012-08-01

    In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications in green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy efficiency and

  5. Effects of micro- and nano-structures on the self-cleaning behaviour of lotus leaves

    Science.gov (United States)

    Cheng, Y. T.; Rodak, D. E.; Wong, C. A.; Hayden, C. A.

    2006-03-01

    When rain falls on lotus leaves water beads up with a high contact angle. The water drops promptly roll off the leaves, collecting dirt along the way. This self-cleaning ability or lotus effect has, in recent years, stimulated much research effort worldwide for a variety of applications ranging from self-cleaning window glasses, paints, and fabrics to low friction surfaces. What are the mechanisms giving rise to the lotus effect? Although chemical composition and surface structure are believed important, a systematic experimental investigation of their effects is still lacking. By altering the surface structure of the leaves while keeping their chemical composition approximately the same, we report in this study the influence of micro- and nano-scale structures on the wetting behaviour of lotus leaves. The findings of this work may help design self-cleaning surfaces and improve our understanding of wetting mechanisms.

  6. Toward an effective implementation of clean development mechanism projects in China

    International Nuclear Information System (INIS)

    Zhang Zhongxiang

    2006-01-01

    With the already huge and growing amount of greenhouse gas emissions and a great deal of low-cost abatement options available, China is widely expected as the world's number one host country of clean development mechanism (CDM) projects. But, making this potential a reality represents a significant challenge for China, because there has been a general lack of awareness by both the Chinese government and business communities, clear institutional structure, and implementation strategy. This has raised great concern about China's ability to compete internationally for CDM projects and exploit fully its CDM potential. This paper aims to address how CDM projects will be effectively implemented in China by examining the major CDM capacity building projects in China with bilateral and multilateral donors, the treatment of low-cost, non-priority CDM projects, and how a system for application, approval, and implementation of CDM projects is set up in China and what roles the main institutional actors are going to play in the system. We conclude that these capacity building assistances, the establishment of streamlined and transparent CDM procedures and sound governance, and the lessons learned and experience gained from the implementation of the CDM project in Inner Mongolia and the two Prototype Carbon Fund' projects will help China to take advantage of CDM opportunities. Moreover, in order to further capitalize on its CDM potential, there is a pressing need for the Chinese government to amend its current interim CDM regulations, in particular those controversial provisions on the eligibility to participate in CDM projects in China and the distribution of the revenues derived from CDM project between the project developer and the Chinese government. We believe that taking these capacity building projects and the recommended actions to clearly define the sustainable development objective of the CDM and disseminate CDM knowledge to local authorities and project developers as

  7. Effectiveness of feeding large kibbles with mechanical cleaning properties in cats with gingivitis

    NARCIS (Netherlands)

    Vrieling, HE; Theyse, LFH; van Winkelhoff, AJ; Dijkshoorn, NA; Logan, EI; Picovet, P

    2005-01-01

    Effectiveness of feeding large kibbles with mechanical cleaning properties in cats with gingivitis periodontal disease is the most common acquired oral disease in cats. it starts with plaque accumulation and gingivitis. The aim of this study was to evaluate the effectiveness of different types of

  8. The effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes

    NARCIS (Netherlands)

    Bucx, M. J. L.; de Gast, H. M.; Veldhuis, J.; Hassing, L. H.; Meulemans, A.; Kammeyer, A.

    2003-01-01

    The increased use of thermal decontamination procedures for fibrelight laryngoscope blades, to comply with international guidelines, will have considerable economical effects. We evaluated the effect of mechanical cleaning plus thermal disinfection at 90degreesC, with or without subsequent steam

  9. Effect of alkaline cleaning and activation on aluminum alloy 7075-T6

    International Nuclear Information System (INIS)

    Joshi, Simon; Fahrenholtz, William G.; O'Keefe, Matthew J.

    2011-01-01

    The effect of alkaline cleaning and activation on the composition and thickness of the oxide layer on aluminum alloy 7075-T6 was studied. E-pH diagrams were developed to predict the effect of alkaline cleaning and activation solutions on the stability of the oxide surface layers. The thickness of the native oxide layer was determined to be ∼30 nm by Auger electron spectroscopy depth profiling analysis. The outer ∼20 nm was rich in magnesium while the remaining ∼10 nm was rich in aluminum. Cleaning in a 9.1 pH alkaline solution was found to remove the magnesium-rich layer and leave behind an aluminum-rich oxide layer ∼10 nm thick. Activation in alkaline solutions of NaOH (pH > 12.9) or Na 2 CO 3 (pH > 11.5) produced an oxide that was ∼20 to 60 nm thick and rich in magnesium. Alkaline cleaning and activation altered the oxide composition and thickness making it possible for deposition of thicker cerium-based conversion coatings (∼100 to 250 nm) compared to only alkaline cleaning (∼30 nm), with application of one spray cycle of deposition solution.

  10. Effect of alkaline cleaning and activation on aluminum alloy 7075-T6

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Simon, E-mail: sjwt5@mst.edu [Department of Materials Science and Engineering, Missouri University of Science and Technology, Rolla, MO 65409 (United States); Fahrenholtz, William G.; O' Keefe, Matthew J. [Department of Materials Science and Engineering, Missouri University of Science and Technology, Rolla, MO 65409 (United States)

    2011-01-01

    The effect of alkaline cleaning and activation on the composition and thickness of the oxide layer on aluminum alloy 7075-T6 was studied. E-pH diagrams were developed to predict the effect of alkaline cleaning and activation solutions on the stability of the oxide surface layers. The thickness of the native oxide layer was determined to be {approx}30 nm by Auger electron spectroscopy depth profiling analysis. The outer {approx}20 nm was rich in magnesium while the remaining {approx}10 nm was rich in aluminum. Cleaning in a 9.1 pH alkaline solution was found to remove the magnesium-rich layer and leave behind an aluminum-rich oxide layer {approx}10 nm thick. Activation in alkaline solutions of NaOH (pH > 12.9) or Na{sub 2}CO{sub 3} (pH > 11.5) produced an oxide that was {approx}20 to 60 nm thick and rich in magnesium. Alkaline cleaning and activation altered the oxide composition and thickness making it possible for deposition of thicker cerium-based conversion coatings ({approx}100 to 250 nm) compared to only alkaline cleaning ({approx}30 nm), with application of one spray cycle of deposition solution.

  11. Effects of tongue cleaning on bacterial flora in tongue coating and dental plaque: a crossover study.

    Science.gov (United States)

    Matsui, Miki; Chosa, Naoyuki; Shimoyama, Yu; Minami, Kentaro; Kimura, Shigenobu; Kishi, Mitsuo

    2014-01-14

    The effects of tongue cleaning on reconstruction of bacterial flora in dental plaque and tongue coating itself are obscure. We assessed changes in the amounts of total bacteria as well as Fusobacterium nucleatum in tongue coating and dental plaque specimens obtained with and without tongue cleaning. We conducted a randomized examiner-blind crossover study using 30 volunteers (average 23.7 ± 3.2 years old) without periodontitis. After dividing randomly into 2 groups, 1 group was instructed to clean the tongue, while the other did not. On days 1 (baseline), 3, and 10, tongue coating and dental plaque samples were collected after recording tongue coating score (Winkel tongue coating index: WTCI). After a washout period of 3 weeks, the same examinations were performed with the subjects allocated to the alternate group. Genomic DNA was purified from the samples and applied to SYBR® Green-based real-time PCR to quantify the amounts of total bacteria and F. nucleatum. After 3 days, the WTCI score recovered to baseline, though the amount of total bacteria in tongue coating was significantly lower as compared to the baseline. In plaque samples, the bacterial amounts on day 3 and 10 were significantly lower than the baseline with and without tongue cleaning. Principal component analysis showed that variations of bacterial amounts in the tongue coating and dental plaque samples were independent from each other. Furthermore, we found a strong association between amounts of total bacteria and F. nucleatum in specimens both. Tongue cleaning reduced the amount of bacteria in tongue coating. However, the cleaning had no obvious contribution to inhibit dental plaque formation. Furthermore, recovery of the total bacterial amount induced an increase in F. nucleatum in both tongue coating and dental plaque. Thus, it is recommended that tongue cleaning and tooth brushing should both be performed for promoting oral health.

  12. Preliminary Laser Cleaning Studies of a Consolidated Prehistoric Basketry Coming from the Pile Building of Fiave-Carera in the North-East of Italy

    International Nuclear Information System (INIS)

    Belli, R.; Miotello, A.; Mosaner, P.; Toniutti, L.; Bazzanella, M.

    2006-01-01

    In the archaeological field, some specific advantages are recognized to laser cleaning, like, for example, the absence of mechanical contacts with the sample. The cleaning procedures generally involve a multilayer structure (dust, dirty, organic deposits, and, in some cases, consolidant substances). In this work, prehistoric wood samples (found and consolidated in 1970s) have been laser irradiated (KrF excimer laser) in order to restore their original surface aspect. A certain amount of burned matter was also present. Samples came from a fragment of a prehistoric basketry found in the lake dwelling site of Fiave-Carera, Trento, Italy (1500-1400 BC). It was observed that the laser cleaning effects are strictly dependent on the irradiation parameters (power density and number of pulses). Efficient material removal was possible by using appropriate energy density. Moreover, for lower laser energy density, special structures appeared on the surface of the consolidating substance that we attributed to heating-induced stresses on the consolidant surface.

  13. Examining factors that influence the effectiveness of cleaning antineoplastic drugs from drug preparation surfaces: a pilot study.

    Science.gov (United States)

    Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George

    2014-06-01

    Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.

  14. Testing the cleaning effectiveness of new ecological aqueous dispersions applied on old icons

    Science.gov (United States)

    Vasilache, Viorica; Sandu, Irina Crina Anca; Pruteanu, Silvea; Caldeira, Ana Teresa; Simionescu, Atena Elena; Sandu, Ion

    2016-03-01

    Adherent deposits are very aggressive towards ancient heritage paintings since they affect the varnish and the painting's layers, sometimes reaching the preparative layers. The biggest problem to the restorer is their removal without affecting the patina, the transparent varnish (well preserved) and fine colour glazes made during painting. Therefore, their removal requires preliminary cleaning tests that allow the optimization of the cleaning system composition that is going to be used. The study was focused on organic natural systems, as colourless supernatants, some of them used during ages, but insufficiently studied. The paper presents an evaluation of the effectiveness of cleaning varnished icons of the nineteenth century, with complex conservation cases using supernatants derived from aqueous dispersions extracted from vegetables and dry indigenous herbal infusions. Best results, after six consecutive cleaning steps, on tempera old icon was obtained for a mixture made of mature white onion juice + extract of Soapwort flowers + corn silk tea + acacia tea. As a best result after just one cleaning step was obtained for a quaternary mixture composed from mature white onion juice + mature carrot juice + corn silk tea + aqueous extract of Soapwort flowers.

  15. Short-term respiratory effects of cleaning exposures in female domestic cleaners.

    Science.gov (United States)

    Medina-Ramón, M; Zock, J P; Kogevinas, M; Sunyer, J; Basagaña, X; Schwartz, J; Burge, P S; Moore, V; Antó, J M

    2006-06-01

    Symptoms of obstructive lung disease in domestic cleaners have been related to the use of bleach and other irritant cleaning products. The short-term effects of cleaning exposures on respiratory symptoms and peak expiratory flow (PEF) were investigated in domestic cleaners with respiratory disorders. In a panel study, 43 female domestic cleaners with a recent history of asthma and/or chronic bronchitis completed a 2-week diary, collecting information on respiratory symptoms, PEF and cleaning exposures. Mixed regression models were used to assess daily changes in symptoms and PEF associated with specific cleaning exposures. The probability of having work-related asthma was individually assessed by a computerised diagnostic system and an occupational asthma expert. Lower respiratory tract symptoms were more common on working days and were predominantly associated with exposure to diluted bleach, degreasing sprays/atomisers and air fresheners. Associations with upper respiratory tract symptoms and PEF were less apparent. Eleven (30%) subjects scored positively for work-related asthma. It is concluded that exposure to certain irritant cleaning products aggravates lower respiratory tract symptoms in female domestic cleaners with asthma or chronic bronchitis.

  16. Effectiveness of deep cleaning followed by hydrogen peroxide decontamination during high Clostridium difficile infection incidence.

    Science.gov (United States)

    Best, E L; Parnell, P; Thirkell, G; Verity, P; Copland, M; Else, P; Denton, M; Hobson, R P; Wilcox, M H

    2014-05-01

    Clostridium difficile infection (CDI) remains an infection control challenge, especially when environmental spore contamination and suboptimal cleaning may increase transmission risk. To substantiate the long-term effectiveness throughout a stroke rehabilitation unit (SRU) of deep cleaning and hydrogen peroxide decontamination (HPD), following a high incidence of CDI. Extensive environmental sampling (342 sites on each occasion) for C. difficile using sponge wipes was performed: before and after deep cleaning with detergent/chlorine agent; immediately following HPD; and on two further occasions, 19 days and 20 weeks following HPD. C. difficile isolates underwent polymerase chain reaction ribotyping and multi-locus variable repeat analysis (MLVA). C. difficile was recovered from 10.8%, 6.1%, 0.9%, 0% and 3.5% of sites at baseline, following deep cleaning, immediately after HPD, and 19 days and 20 weeks after HPD, respectively. C. difficile ribotypes recovered after deep cleaning matched those from CDI cases in the SRU during the previous 10 months. Similarly, 10/12 of the positive sites identified at 20 weeks post-HPD harboured the same C. difficile ribotype (002) and MLVA pattern as the isolate from the first post-HPD CDI case. CDI incidence [number of cases on SRU per 10 months (January-October 2011)] declined from 20 before to seven after the intervention. HPD, after deep cleaning with a detergent/chlorine agent, was highly effective for removing environmental C. difficile contamination. Long-term follow-up demonstrated that a CDI symptomatic patient can rapidly recontaminate the immediate environment. Determining a role for HPD should include long-term cost-effectiveness evaluations. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Combustion characteristics of intensively cleaned coal fractions. Effect of mineral matter

    Energy Technology Data Exchange (ETDEWEB)

    Rubiera, F.; Arenillas, A.; Fuente, E.; Pis, J.J. [Inst. Nacional de Carbon, Oviedo (Spain); Ivatt, S. [ETSU, Harwell, Didcot (United Kingdom)

    1997-12-31

    The purpose of this work has been to assess the effect that intensive coal cleaning exerts on the combustion behaviour of different density-separated coal fractions. Samples with ash contents varying from 39% for the raw coal, to 2% for the cleanest fraction were obtained after density separation. Temperature-programmed combustion and isothermal gasification in air were used to measure the reactivities of the parent coal and the cleaned fractions. Coal and char reactivities increased with increasing ash content of the samples. Thermal analysis-mass spectrometry of the low-temperature ashes was also carried out in order to study the reactions of coal minerals under combustion conditions. (orig.)

  18. Investigation of effective forensic cleaning methods for bullet and cartridge case samples

    Science.gov (United States)

    Shuherk, Cassie Marie

    Bullet and cartridge case evidence may potentially link weapons and crimes through the comparison of toolmark patterns. This analysis relies on the clarity of the toolmarks and the ability of the examiner to identify patterns on the evidence. These patterns may be distorted by debris such as soil, blood, cyanoacrylate, and construction materials. Despite the potential importance of bullet and cartridge case evidence, few investigations of proper cleaning methods have been conducted. The present study was designed to examine the effects of various cleaning solutions and application methods on copper and brass bullets and cartridge cases. Additionally, this research investigated the efficacy of these cleaning protocols on the common evidence contaminants blood and cyanoacrylate. No cleaning method was found to be universally effective on both contaminant types and nondestructive to the metal surface. Ultrasonication was the most efficient application method employed when used in conjunction with an appropriate cleaning solution. Acetone proved to be safe and successful at removing heavy cyanoacrylate deposits from brass cartridge cases without damaging the metal. Although sulfuric acid removed most of the cyanoacrylate from the brass cartridge case, ultrasonication of the fumed cartridge cases in sulfuric acid caused the nickel-plated primer caps to turn black. Additionally, etching occurred when sulfuric acid was allowed to dry on the cartridge case surface. Citric acid, salt-flour-vinegar paste, TergazymeRTM, and water did not effectively remove the cyanoacrylate from the cartridge cases, but the solutions were safe to use on the brass and sometimes resulted in a shinier surface. Regardless of the cleaning method employed, the bloodstained bullets retained most or all of the underlying brown tarnish. Ultrasonication with sulfuric acid was successful at removing some blood-initiated tarnishing; however, the removal of residues was not complete, making it difficult

  19. High Rate Production of Clean Water Based on the Combined Photo-Electro-Thermal Effect of Graphene Architecture.

    Science.gov (United States)

    Cui, Linfan; Zhang, Panpan; Xiao, Yukun; Liang, Yuan; Liang, Hanxue; Cheng, Zhihua; Qu, Liangti

    2018-04-23

    The use of abundant solar energy for regeneration and desalination of water is a promising strategy to address the challenge of a global shortage of clean water. Progress has been made to develop photothermal materials to improve the solar steam generation performance. However, the mass production rate of water is still low. Herein, by a rational combination of photo-electro-thermal effect on an all-graphene hybrid architecture, solar energy can not only be absorbed fully and transferred into heat, but also converted into electric power to further heat up the graphene skeleton frame for a much enhanced generation of water vapor. As a result, the unique graphene evaporator reaches a record high water production rate of 2.01-2.61 kg m -2 h -1 under solar illumination of 1 kW m -2 even without system optimization. Several square meters of the graphene evaporators will provide a daily water supply that is enough for tens of people. The combination of photo-electro-thermal effect on graphene materials offers a new strategy to build a fast and scalable solar steam generation system, which makes an important step towards a solution for the scarcity of clean water. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Molecular effects in ion-electron emission from clean metal surfaces

    International Nuclear Information System (INIS)

    Baragiola, R.A.; Alonso, E.V.; Auciello, O.; Ferron, J.; Lantschner, G.; Oliva Florio, A.

    1978-01-01

    The authors have measured electron emission yields from clean Al, Cu and Ag under 2-50 keV H + , D + , H 2 + impact. It is found that molecular ion yields are lower than twice the yield of atomic ions. No isotope effects are observed for equal-velocity ions. (Auth.)

  1. Clean Energy Finance Tool

    Science.gov (United States)

    State and local governments interested in developing a financing program can use this Excel tool to support energy efficiency and clean energy improvements for large numbers of buildings within their jurisdiction.

  2. Effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance

    Science.gov (United States)

    Dietze, Uwe; Dress, Peter; Waehler, Tobias; Singh, Sherjang; Jonckheere, Rik; Baudemprez, Bart

    2011-03-01

    Extreme Ultraviolet Lithography (EUVL) is considered the leading lithography technology choice for semiconductor devices at 16nm HP node and beyond. However, before EUV Lithography can enter into High Volume Manufacturing (HVM) of advanced semiconductor devices, the ability to guarantee mask integrity at point-of-exposure must be established. Highly efficient, damage free mask cleaning plays a critical role during the mask manufacturing cycle and throughout the life of the mask, where the absence of a pellicle to protect the EUV mask increases the risk of contamination during storage, handling and use. In this paper, we will present effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance, which employs an intelligent, holistic approach to maximize Mean Time Between Cleans (MBTC) and extend the useful life span of the reticle. The data presented will demonstrate the protection of the capping and absorber layers, preservation of pattern integrity as well as optical and mechanical properties to avoid unpredictable CD-linewidth and overlay shifts. Experiments were performed on EUV blanks and pattern masks using various process conditions. Conditions showing high particle removal efficiency (PRE) and minimum surface layer impact were then selected for durability studies. Surface layer impact was evaluated over multiple cleaning cycles by means of UV reflectivity metrology XPS analysis and wafer prints. Experimental results were compared to computational models. Mask life time predictions where made using the same computational models. The paper will provide a generic overview of the cleaning sequence which yielded best results, but will also provide recommendations for an efficient in-fab mask maintenance scheme, addressing handling, storage, cleaning and inspection.

  3. Attitudes and beliefs, not just knowledge, influence the effectiveness of environmental cleaning by environmental service workers.

    Science.gov (United States)

    Matlow, Anne G; Wray, Rick; Richardson, Susan E

    2012-04-01

    Hospital environmental service workers (ESWs) play an important role in interrupting the chain of infection because the environment is a reservoir for nosocomial pathogens. Improving ESWs' knowledge through education has been shown to improve ESW cleaning, but the behavioral determinants of their work have not been studied. Understanding and targeting ESWs' attitudes and beliefs may inform strategies to improve environmental cleaning. With the theory of planned behavior as framework, we used questionnaires and focus groups to examine intensive care unit ESWs' attitudes, beliefs [behavioral, normative, and control], and control) and intent about their job. Baseline quantitative microbial cultures of high-touch services were performed before and after cleaning. After an educational intervention addressing their attitudes, beliefs, and general infection control knowledge, attitudes, beliefs, and microbial contamination were reassessed. Beliefs were uniformly strong (4.5/5-5/5), and normative beliefs correlated best with intent to clean (R(2) = 0.3). Themes elicited from the focus groups included "me versus them," lack of appreciation, pride in work, and "if it were me." The rate of environmental contamination was significantly improved after the intervention (P = .0074 vs P = .0023, respectively); the measured relationship among attitudes, beliefs, and intent was not significantly changed. ESWs' attitudes and beliefs about their job may impact their intent to clean and in turn the effectiveness of their efforts. Understanding and addressing these attitudes and beliefs can be used to inform strategies for sustained improvement of environmental cleaning. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  4. Soiling, Cleaning, and Weathering Effects on Aircraft Polyurethane Topcoats

    Science.gov (United States)

    1988-03-01

    contact angle indicates a decrease in the surface energy of the coating (10), thus indicating a change in the surface chemistry . This effect is...A. Voet, CARBON BLACK: PHYSICS, CHEMISTRY , AND ELASTOMER REINFORCEMENT, Marcel Dekker, Inc., New York, 1976. 8 * NADC 88031-60 0 II- 0 00 00 z 0 >0...1 Attn: K. Silberger 20846 S. Normandie Ave. Torrance, CA 90502 Ciba-Geigy Corp ............................................................... 1I * Antn: R. Varron Ardsley, NY 10502 iii0~~A1111[1l,31W W

  5. Effectiveness of bone cleaning process using chemical and entomology approaches: time and cost.

    Science.gov (United States)

    Lai, Poh Soon; Khoo, Lay See; Mohd Hilmi, Saidin; Ahmad Hafizam, Hasmi; Mohd Shah, Mahmood; Nurliza, Abdullah; Nazni, Wasi Ahmad

    2015-08-01

    Skeletal examination is an important aspect of forensic pathology practice, requiring effective bone cleaning with minimal artefact. This study was conducted to compare between chemical and entomology methods of bone cleaning. Ten subjects between 20 and 40 years old who underwent uncomplicated medico-legal autopsies at the Institute of Forensic Medicine Malaysia were randomly chosen for this descriptive cross sectional study. The sternum bone was divided into 4 parts, each part subjected to a different cleaning method, being two chemical approaches i.e. laundry detergent and a combination of 6% hydrogen peroxide and powder sodium bicarbonate and two entomology approaches using 2nd instar maggots of Chrysomyia rufifacies and Ophyra spinigera. A scoring system for grading the outcome of cleaning was used. The effectiveness of the methods was evaluated based on average weight reduction per day and median number of days to achieve the average score of less than 1.5 within 12 days of the bone cleaning process. Using maggots was the most time-effective and costeffective method, achieving an average weight reduction of 1.4 gm per day, a median of 11.3 days to achieve the desired score and an average cost of MYR 4.10 per case to reach the desired score within 12 days. This conclusion was supported by blind validation by forensic specialists achieving a 77.8% preference for maggots. Emission scanning electron microscopy evaluation also revealed that maggots especially Chrysomyia rufifacies preserved the original condition of the bones better allowing improved elucidation of bone injuries in future real cases.

  6. Building Effective Marketing Communications in Tourism

    Directory of Open Access Journals (Sweden)

    Gorlevskaya Liudmila

    2016-12-01

    Full Text Available In the world of rapid technological evolution and economy of digitalization, consumers are continuously changing. Tourists are among the first. Their behaviour, media consumption, engagement level and expectations must influence on transformation of applied communication tools. In recent decades, the pace of change became faster. Media consumption has shifted to Internet, Mobile and innovative mediums. The paper proposes modern forms of communication tools on different stages of making-decision process and describes role of each to build marketing communications of tourism industry actors in a more effective way.

  7. Plasma Cleaning

    Science.gov (United States)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  8. Building

    OpenAIRE

    Seavy, Ryan

    2014-01-01

    Building for concrete is temporary. The building of wood and steel stands against the concrete to give form and then gives way, leaving a trace of its existence behind. Concrete is not a building material. One does not build with concrete. One builds for concrete. MARCH

  9. Effectiveness of cleaning-disinfection wipes and sprays against multidrug-resistant outbreak strains.

    Science.gov (United States)

    Kenters, Nikki; Huijskens, Elisabeth G W; de Wit, Sophie C J; van Rosmalen, Joost; Voss, Andreas

    2017-08-01

    Hospital rooms play an important role in the transmission of several health care-associated pathogens. During the last few years, a number of innovative cleaning-disinfecting products have been brought to market. In this study, commercially available products combining cleaning and disinfection were compared, using 2 different application methods. The aim was to determine which product was most effective in simultaneous cleaning and disinfection of surfaces. Seven cleaning-disinfecting wipes and sprays based on different active ingredients were tested for their efficacy in removal of microbial burden and proteins. Efficacy was tested with known Dutch outbreak strains: vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae OXA-48, or Acinetobacter baumannii. For all bacteria, ready-to-use cleaning-disinfecting products reduced the microbial count with a log 10 reduction >5 with a 5-minute exposure time, with the exception of a spray based on hydrogen peroxide. Omitting the aforementioned hydrogen peroxide spray, there were no significant differences between use of a wipe or spray in bacterial load reduction. Using adenosine triphosphate (ATP) measurements, a significant difference in log 10 relative light units (RLU) reduction between various bacteria (P ≤ .001) was observed. In general, a >5 log 10 reduction of colony forming units (CFU) for tested wipes and sprays was obtained for all tested bacteria strains, with exception of hydrogen peroxide spray and VRE. Although ATP may show a difference between pre- and postcleaning, RLU reduction does not correlate with actual CFU reductions. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Practical issues in laser cleaning of stone and painted artefacts: optimisation procedures and side effects

    Science.gov (United States)

    Pouli, Paraskevi; Oujja, Mohamed; Castillejo, Marta

    2012-02-01

    In the last twenty years lasers have acquired an important role in the study and the preservation of Cultural Heritage (CH) objects and Monuments, as they have effectively illuminated a number of complex diagnostic and restoration problems. Their unique properties have enabled their use in a wide range of conservation applications, since they ensure interventions with precise control, material selectivity and immediate feedback. Surface cleaning, based on laser ablation, is a delicate, critical and irreversible process, which, given the multitude of materials that may be present on a CH object and the often fragile or precarious condition of the original surfaces, is fraught with many potential complications. Therefore it is crucial to choose the best possible laser cleaning methodology for each individual case, which involves optimising the laser parameters according to material properties, as well as the thorough knowledge of the ablation mechanisms involved. In this context the systematic investigation and elucidation of potential damage or side effects occurring upon cleaning is essential, as it delineates the possibilities and limitations of laser ablation and allows the fine-tuning of the operating parameters for a successful cleaning intervention. This paper is an overview of studies investigating the mechanisms which are responsible for the laser-induced discoloration effects. Emphasis is given on the yellowing coloration observed on stonework upon infrared (IR) ablation of pollution encrustations, while the various theories introduced to approach the different physical and/or chemical processes and mechanisms responsible for such side effects are discussed. In this respect the different laser cleaning methodologies, which are based on the use of laser systems with different pulse durations and wavelength characteristics, introduced in order to rectify or prevent discoloration on stonework are presented. In parallel, the darkening phenomena which occur upon

  11. Effect of sponge ball cleaning on removing barnacles in condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Mimura, K; Minamoto, K; Kyohara, S [Kobe Steel Ltd. (Japan)

    1977-07-01

    Considering environmental protection, the recent tendency has been to give up chlorination of cooling water for power stations. The experimental results show that cooling sea-water without chlorination cannot get rid of barnacles which grow inside condenser tubes when the speed of the cooling water is less than 1 m/s. Cleaning by sponge balls 2 -- 3 times a week is found to be effective for both barnacle prevention and inactive film formation on the tube surface.

  12. The effect of consumer expectations and perceptions regarding sanitation on access to clean water

    CSIR Research Space (South Africa)

    Duncker, Louiza

    2017-08-01

    Full Text Available and Sanitation Centre. Drangert, Jan-Olof, Louiza Christina Duncker, Gertrude Matsebe, and Victoria Abu Atukunda. 2006. “Ecological Sanitation, Urban Agriculture and Gender in Peri- Journal of Ethical Urban Living 34 urban Settlements: A Comparative Study... the author worked on. Publication Details Journal of Ethical Urban Living (ISSN: 2470-2641). August, 2017. Volume 1, Issue 1. Citation Duncker, Louiza. 2017. “The Effect of Consumer Expectations and Perceptions Regarding Sanitation on Access to Clean Water...

  13. International Clean Energy Coalition

    Energy Technology Data Exchange (ETDEWEB)

    Erin Skootsky; Matt Gardner; Bevan Flansburgh

    2010-09-28

    In 2003, the National Association of Regulatory Utility Commissioners (NARUC) and National Energy Technology Laboratories (NETL) collaboratively established the International Clean Energy Coalition (ICEC). The coalition consisting of energy policy-makers, technologists, and financial institutions was designed to assist developing countries in forming and supporting local approaches to greenhouse gas mitigation within the energy sector. ICEC's work focused on capacity building and clean energy deployment in countries that rely heavily on fossil-based electric generation. Under ICEC, the coalition formed a steering committee consisting of NARUC members and held a series of meetings to develop and manage the workplan and define successful outcomes for the projects. ICEC identified India as a target country for their work and completed a country assessment that helped ICEC build a framework for discussion with Indian energy decisionmakers including two follow-on in-country workshops. As of the conclusion of the project in 2010, ICEC had also conducted outreach activities conducted during United Nations Framework Convention on Climate Change (UNFCCC) Ninth Conference of Parties (COP 9) and COP 10. The broad goal of this project was to develop a coalition of decision-makers, technologists, and financial institutions to assist developing countries in implementing affordable, effective and resource appropriate technology and policy strategies to mitigate greenhouse gas emissions. Project goals were met through international forums, a country assessment, and in-country workshops. This project focused on countries that rely heavily on fossil-based electric generation.

  14. Kinetic equations for clean superconductors: Application to the flux flow hall effect

    International Nuclear Information System (INIS)

    Kopnin, N.B.

    1994-01-01

    The kinetic equations for clean superconductors (l>>ζ) are derived. expanding the equations for the time dependent Green functions in the quasiclassical parameter, the new contributions are found which contain the derivatives of the distribution functions with respect to the quasiparticle momentum. The transition from the ultra-clean case (no relaxation) to a relaxation-dominated behavior, for which the kinetic equations coincide with the usual quasiclassical approximation, occurs for the relaxation time of the order of ℎE F /Δ 2 . The kinetic equations can be used for various dynamic processes in superconductors including the flux-flow Hall effect. The derived equations, after necessary modifications for the p-wave pairing, are especially suitable for nonstationary problems in the theory of superfluidity of 3 He

  15. Effects of different cleaning treatments on heavy metal removal of Panax notoginseng (Burk) F. H. Chen.

    Science.gov (United States)

    Dahui, Liu; Na, Xu; Li, Wang; Xiuming, Cui; Lanping, Guo; Zhihui, Zhang; Jiajin, Wang; Ye, Yang

    2014-01-01

    The quality and safety of Panax notoginseng products has become a focus of concern in recent years. Contamination with heavy metals is one of the important factors as to P. notoginseng safety. Cleaning treatments can remove dust, soil, impurities or even heavy metals and pesticide residues on agricultural products. But effects of cleaning treatments on the heavy metal content of P. notoginseng roots have still not been studied. In order to elucidate this issue, the effects of five different cleaning treatments (CK, no treatment; T1, warm water (50°C) washing; T2, tap water (10°C) washing; T3, drying followed by polishing; and T4, drying followed by tap water (10°C) washing) on P. notoginseng roots' heavy metal (Cu, Pb, Cd, As and Hg) contents were studied. The results showed that heavy metal (all five) content in the three parts all followed the order of hair root > rhizome > root tuber under the same treatment. Heavy metal removals were in the order of Hg > As > Pb > Cu > Cd. Removal efficiencies of the four treatments were in the order of T2 > T1 > T3 > T4. Treatments (T1-T4) could decrease the contents of heavy metal in P. notoginseng root significantly. Compared with the requirements of WM/T2-2004, P. notoginseng roots' heavy metal contents of Cu, Pb, As and Hg were safe under treatments T1 and T2. In conclusion, the cleaning process after production was necessary and could reduce the content of heavy metals significantly. Fresh P. notoginseng root washed with warm water (T2) was the most efficient treatment to remove heavy metal and should be applied in production.

  16. Photocatalytic Solutions Create Self-Cleaning Surfaces

    Science.gov (United States)

    2013-01-01

    A Stennis Space Center researcher investigating the effectiveness of photocatalytic materials for keeping the Center's buildings free of grime turned to a solution created by PURETi Inc. of New York City. Testing proved successful, and NASA and the company now share a Dual Use Technology partnership. PURETi's coatings keep surfaces clean and purify surrounding air, eliminating pollution, odors, and microbes.

  17. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics.

    Science.gov (United States)

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim; Tuncdemir, Ali Riza

    2012-11-01

    The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (α=0.05). THE DENTIN CLEANING METHODS DID NOT SIGNIFICANTLY AFFECT THE SBS OF CERAMIC DISCS TO DENTIN AS FOLLOWS: dental explorer, pumice, cleaning bur, and Er:YAG laser. The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.

  18. Substrate Effect on Plasma Clean Efficiency in Plasma Enhanced Chemical Vapor Deposition System

    Directory of Open Access Journals (Sweden)

    Shiu-Ko JangJian

    2007-01-01

    Full Text Available The plasma clean in a plasma-enhanced chemical vapor deposition (PECVD system plays an important role to ensure the same chamber condition after numerous film depositions. The periodic and applicable plasma clean in deposition chamber also increases wafer yield due to less defect produced during the deposition process. In this study, the plasma clean rate (PCR of silicon oxide is investigated after the silicon nitride deposited on Cu and silicon oxide substrates by remote plasma system (RPS, respectively. The experimental results show that the PCR drastically decreases with Cu substrate compared to that with silicon oxide substrate after numerous silicon nitride depositions. To understand the substrate effect on PCR, the surface element analysis and bonding configuration are executed by X-ray photoelectron spectroscopy (XPS. The high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS is used to analyze microelement of metal ions on the surface of shower head in the PECVD chamber. According to Cu substrate, the results show that micro Cu ion and the CuOx bonding can be detected on the surface of shower head. The Cu ion contamination might grab the fluorine radicals produced by NF3 ddissociation in the RPS and that induces the drastic decrease on PCR.

  19. Ni/YSZ electrode degradation studied by impedance spectroscopy: Effects of gas cleaning and current density

    DEFF Research Database (Denmark)

    Hauch, Anne; Mogensen, Mogens Bjerg

    2010-01-01

    Anode supported (Ni/YSZ–YSZ–LSM/YSZ) solid oxide fuel cells were tested and the degradation over time was monitored and analyzed by impedance spectroscopy. Test conditions were chosen to focus on the anode degradation and all tests were operated at 750 °C. O2 was supplied to the cathode...... and the anode inlet gas mixture had a high p(H2O)/p(H2) ratio of 0.4/0.6. Commercially available gasses were applied. Cells were tested over a few hundred hours applying varying current densities (OCV, 0.75 A/cm2 and 1 A/cm2). To investigate the effects of possible impurities in the inlet gas stream...... on the anode degradation, tests were set-up both with and without gas cleaning. Gas cleaning was done by passing the H2 over porous nickel at room temperature. It was found that cleaning of the inlet H2 gas more than halved the anode degradation under current load. For tests at OCV the increase in the Ni...

  20. Effect of Unprofessional Supervision on Durability of Buildings.

    Science.gov (United States)

    Yahaghi, Javad

    2018-02-01

    The durability of buildings which depends on the nature of the supervisory system used in their construction is an important feature of the construction industry. This article tries to draw the readers' attention to the effect of untrained and unprofessional building supervisors and their unethical performance on the durability of buildings.

  1. Lessons learned from a rigorous peer-review process for building the Climate Literacy and Energy Awareness (CLEAN) collection of high-quality digital teaching materials

    Science.gov (United States)

    Gold, A. U.; Ledley, T. S.; McCaffrey, M. S.; Buhr, S. M.; Manduca, C. A.; Niepold, F.; Fox, S.; Howell, C. D.; Lynds, S. E.

    2010-12-01

    The topic of climate change permeates all aspects of our society: the news, household debates, scientific conferences, etc. To provide students with accurate information about climate science and energy awareness, educators require scientifically and pedagogically robust teaching materials. To address this need, the NSF-funded Climate Literacy & Energy Awareness Network (CLEAN) Pathway has assembled a new peer-reviewed digital collection as part of the National Science Digital Library (NSDL) featuring teaching materials centered on climate and energy science for grades 6 through 16. The scope and framework of the collection is defined by the Essential Principles of Climate Science (CCSP 2009) and a set of energy awareness principles developed in the project. The collection provides trustworthy teaching materials on these socially relevant topics and prepares students to become responsible decision-makers. While a peer-review process is desirable for curriculum developer as well as collection builder to ensure quality, its implementation is non-trivial. We have designed a rigorous and transparent peer-review process for the CLEAN collection, and our experiences provide general guidelines that can be used to judge the quality of digital teaching materials across disciplines. Our multi-stage review process ensures that only resources with teaching goals relevant to developing climate literacy and energy awareness are considered. Each relevant resource is reviewed by two individuals to assess the i) scientific accuracy, ii) pedagogic effectiveness, and iii) usability/technical quality. A science review by an expert ensures the scientific quality and accuracy. Resources that pass all review steps are forwarded to a review panel of educators and scientists who make a final decision regarding inclusion of the materials in the CLEAN collection. Results from the first panel review show that about 20% (~100) of the resources that were initially considered for inclusion

  2. Partial pit exhaust improves indoor air quality and effectiveness of air cleaning in livestock housing

    DEFF Research Database (Denmark)

    Zhang, Guoqiang; Bjerg, B.; Zong, C.

    2017-01-01

    Ammonia and odor emissions from livestock production systems cause negative impact on atmospheric environment and local society. It is, therefore, important to develop cost-effective methods to reduce these emissions. Air cleaning technologies, including chemical and biological filters, have been...... and experimental investigations, to identify important factors that may affect the system performances for removal of ammonia and other pollutants from the animal housing and to address the extension work that may be needed to apply the method in actual production scales. It is shown that PPAE is an effective...

  3. The effect of cleaning substances on the surface of denture base material.

    Science.gov (United States)

    Žilinskas, Juozas; Junevičius, Jonas; Česaitis, Kęstutis; Junevičiūtė, Gabrielė

    2013-12-11

    The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material. Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, "plates"). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste ("Colgate Total"), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning. No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (pbaking soda--the total reflection reduction was 4.82 ± 0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect--4.6 ± 0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface - 3.8 9 ± 0.07%. All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

  4. Enhanced Chemical Cleaning: Effectiveness Of The UV Lamp To Decompose Oxalates

    International Nuclear Information System (INIS)

    Ketusky, E.; Huff, T.; Sudduth, C.

    2010-01-01

    Enhanced Chemical Cleaning is a new process scheduled to begin cleaning Savannah River Site High Level Waste Tanks in 2012. It is an improvement over the current chemical cleaning method, in that it minimizes downstream impacts on the High Level Waste System. It is based on a state of the art scale removal process used on the secondary side of nuclear power plants, with modifications to accommodate the unique constraints created by the tanks. Both Enhanced Chemical Cleaning and the scale removal process are founded on dissolving metal oxides/hydroxides using oxalic acid, with subsequent oxalate decomposition via hydroxylation using ozone or peroxide, and UV light as a catalyst. A divergence Enhanced Chemical Cleaning has from nuclear power scale removal is the significantly increased solids concentration during oxalate decomposition. These solids can limit the ability of the UV light to create hydroxyl radicals, either by limiting the ability of the light to penetrate through the solution, or by increasing the fouling rate on the UV light. Both will decrease the overall catalytic effectiveness, thereby decreasing the concentration of formed hydroxyl radicals. The hydroxyl radicals are the driving force behind the oxalate decomposition. To understand the impact of increased solids, testing was performed using a medium pressure UV light inside an ozone supplied Oxalate Decomposition Reactor. Using a dissolved metal sludge simulant with an initial oxalate concentration greater than 12,000 ppm, and an initial pH of about 2.0, the spent acid solution was recirculated through the reactor, while the UV light was allowed to foul. For the first few hours, the oxalate decomposition rate was about 1,300 ppm/hour. After about 3 hours, enough time for the UV lamp to foul, the oxalate decomposition rate decreased to about 500 ppm/hour. The decomposition rate then remained roughly constant for the next 16 hours. Overall, testing showed that the oxalate destruction rate decreased

  5. ENHANCED CHEMICAL CLEANING: EFFECTIVENESS OF THE UV LAMP TO DECOMPOSE OXALATES

    Energy Technology Data Exchange (ETDEWEB)

    Ketusky, E.; Huff, T.; Sudduth, C.

    2010-01-19

    Enhanced Chemical Cleaning is a new process scheduled to begin cleaning Savannah River Site High Level Waste Tanks in 2012. It is an improvement over the current chemical cleaning method, in that it minimizes downstream impacts on the High Level Waste System. It is based on a state of the art scale removal process used on the secondary side of nuclear power plants, with modifications to accommodate the unique constraints created by the tanks. Both Enhanced Chemical Cleaning and the scale removal process are founded on dissolving metal oxides/hydroxides using oxalic acid, with subsequent oxalate decomposition via hydroxylation using ozone or peroxide, and UV light as a catalyst. A divergence Enhanced Chemical Cleaning has from nuclear power scale removal is the significantly increased solids concentration during oxalate decomposition. These solids can limit the ability of the UV light to create hydroxyl radicals, either by limiting the ability of the light to penetrate through the solution, or by increasing the fouling rate on the UV light. Both will decrease the overall catalytic effectiveness, thereby decreasing the concentration of formed hydroxyl radicals. The hydroxyl radicals are the driving force behind the oxalate decomposition. To understand the impact of increased solids, testing was performed using a medium pressure UV light inside an ozone supplied Oxalate Decomposition Reactor. Using a dissolved metal sludge simulant with an initial oxalate concentration greater than 12,000 ppm, and an initial pH of about 2.0, the spent acid solution was recirculated through the reactor, while the UV light was allowed to foul. For the first few hours, the oxalate decomposition rate was about 1,300 ppm/hour. After about 3 hours, enough time for the UV lamp to foul, the oxalate decomposition rate decreased to about 500 ppm/hour. The decomposition rate then remained roughly constant for the next 16 hours. Overall, testing showed that the oxalate destruction rate decreased

  6. ToF-SIMS Investigation of the Effectiveness of Acid-Cleaning procedures for Genesis Solar Wind Collectors

    Science.gov (United States)

    Goreva, Y. S.; Humanyun, M.; Burnett, D. S.; Jurewicz, A. J.; Gonzalez, C. P.

    2014-01-01

    ToF-SIMS images of Genesis sample surfaces contain an incredible amount of important information, but they also show that the crash-derived surface contamination has many components, presenting a challenge to cleaning. Within the variability, we have shown that there are some samples which appear to be clean to begin with, e.g. 60471, and some are more contaminated. Samples 60493 and 60500 are a part of a focused study of the effectiveness of aqua regia and/or sulfuric acid cleaning of small flight Si implanted with Li-6 using ToF-SIMS.

  7. Clean data

    CERN Document Server

    Squire, Megan

    2015-01-01

    If you are a data scientist of any level, beginners included, and interested in cleaning up your data, this is the book for you! Experience with Python or PHP is assumed, but no previous knowledge of data cleaning is needed.

  8. Market effects of environmental regulation: coal, railroads, and the 1990 Clean Air Act

    Energy Technology Data Exchange (ETDEWEB)

    Busse, M.R.; Keohane, N.O. [University of California Berkeley, Berkeley, CA (United States)

    2007-01-01

    Many environmental regulations encourage the use of 'clean' inputs. When the suppliers of such an input have market power, environmental regulation will affect not only the quantity of the input used but also its price. We investigate the effect of the Title IV emissions trading program for sulfur dioxide on the market for low-sulfur coal. We find that the two railroads transporting coal were able to price discriminate on the basis of environmental regulation and geographic location. Delivered prices rose for plants in the trading program relative to other plants, and by more at plants near a low-sulfur coal source.

  9. Laser surface cleaning

    International Nuclear Information System (INIS)

    Freiwald, J.G.; Freiwald, D.A.

    1994-01-01

    The objective of this work is a laboratory demonstration that red-lead primer and two-part epoxy paints can be stripped from concrete and metal surfaces using surface cleaning systems based on pulsed-repetition CO 2 lasers. The three goals are to: (1) demonstrate coatings removal, including surface pore cleaning; (2) demonstrate that there is negligible release of ablated contaminants to the environment; and (3) demonstrate that the process will generate negligible amounts of additional waste compared to competing technologies. Phase 1 involved site visits to RMI and Fernald to assess the cleaning issues for buildings and parts. In addition, Phase 1 included detailed designs of a more powerful system for industrial cleaning rates, including laser, articulating optics, ablated-material capture suction nozzle attached to a horizontal raster scanner for floor cleaning, and filtration system. Some concept development is also being done for using robots, and for parts cleaning. In Phase 2 a transportable 6 kW system will be built and tested, with a horizontal surface scanner for cleaning paint from floors. The laboratory tests will again be instrumented. Some concept development will continue for using robots, and for parts cleaning. This report describes Phase 1 results

  10. Effects of plasma cleaning of the Cu seed layer surface on Cu electroplating

    International Nuclear Information System (INIS)

    O, Jun Hwan; Lee, Seong Wook; Kim, Jae Bum; Lee, Chong Mu

    2001-01-01

    Effects of plasma pretreatment to Cu seed/tantalum nitride (TaN)/ borophosphosilicate glass (BPSG) samples on copper (Cu) electroplating were investigated. Copper seed layers were deposited by magnetron sputtering onto tantalum nitride barrier layers before electroplating copper in the forward pulsed mode. The Cu seed layer was cleaned by plasma H 2 and N 2 prior to electroplating a copper film. Cu films electroplated on the copper seed layer with plasma pretreatment showed better electrical and physical properties such as electrical resistivities, surface morphologies, levels of impurities, adhesion and surface roughness than those without plasma pretreatment. It is shown that carbon and metal oxide contaminants at the sputtered Cu seed/TaN surface could be effectively removed by plasma H 2 cleaning. The degree of the (111) prefered orientation of the Cu film with plasma H 2 pretreatment is as high as pulse plated Cu film without plasma pretreatment. Also, plasma H 2 precleaning is more effective in enhancing the Cu electroplating properties onto the Cu seed layer than plasma N 2 precleaning

  11. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

    OpenAIRE

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim; Tuncdemir, Ali Riza

    2012-01-01

    PURPOSE The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and...

  12. Study of Wind Effects on Unique Buildings

    Science.gov (United States)

    Olenkov, V.; Puzyrev, P.

    2017-11-01

    The article deals with a numerical simulation of wind effects on the building of the Church of the Intercession of the Holy Virgin in the village Bulzi of the Chelyabinsk region. We presented a calculation algorithm and obtained pressure fields, velocity fields and the fields of kinetic energy of a wind stream, as well as streamlines. Computational fluid dynamic (CFD) evolved three decades ago at the interfaces of calculus mathematics and theoretical hydromechanics and has become a separate branch of science the subject of which is a numerical simulation of different fluid and gas flows as well as the solution of arising problems with the help of methods that involve computer systems. This scientific field which is of a great practical value is intensively developing. The increase in CFD-calculations is caused by the improvement of computer technologies, creation of multipurpose easy-to-use CFD-packagers that are available to a wide group of researchers and cope with various tasks. Such programs are not only competitive in comparison with physical experiments but sometimes they provide the only opportunity to answer the research questions. The following advantages of computer simulation can be pointed out: a) Reduction in time spent on design and development of a model in comparison with a real experiment (variation of boundary conditions). b) Numerical experiment allows for the simulation of conditions that are not reproducible with environmental tests (use of ideal gas as environment). c) Use of computational gas dynamics methods provides a researcher with a complete and ample information that is necessary to fully describe different processes of the experiment. d) Economic efficiency of computer calculations is more attractive than an experiment. e) Possibility to modify a computational model which ensures efficient timing (change of the sizes of wall layer cells in accordance with the chosen turbulence model).

  13. How effective is mandatory building energy disclosure program in Australia?

    Science.gov (United States)

    Kim, S.; Lim, B. T. H.

    2018-04-01

    Mandatory green building regulations are often considered as the most effective tool to promote better energy efficiency and environmental protection. Nevertheless, its effectiveness compared to the voluntary counterpart has not been fully explored yet. In addressing this gap, this study aims to examine the environmental performance of green building stocks affected by the Australian mandatory building energy disclosure program. To this, this study analysed energy savings and carbon reduction efficiencies using the normalisation approach. The result shows that mandatory energy disclosure program did contribute to the reduction in energy usage and carbon emissions from the affected building stocks. More specifically, affected green building stocks showed a good efficiency especially in carbon reductions. The research results inform policymakers the possible improvement required for the mandatory disclosure program to increase the effectiveness towards dealing with the contemporary environmental issues aroused from the building sector, especially in energy savings perspective.

  14. Effect of Daily Contact Lens Cleaning on Ocular Adverse Events during Extended Wear.

    Science.gov (United States)

    Ozkan, Jerome; Rathi, Varsha M; de la Jara, Percy Lazon; Naduvilath, Thomas; Holden, Brien A; Willcox, Mark D P

    2015-02-01

    The purpose of the study was to assess what effect daily cleaning of contact lenses with a multipurpose disinfection solution (MPDS), during 30 nights extended wear, would have on contact lens-related adverse events. This was a prospective, open-label, randomized, controlled, parallel-group, 3-month clinical study in which 193 participants were dispensed with lotrafilcon A silicone hydrogel lenses for a 30-day extended-wear schedule and with lenses replaced monthly. Participants were randomized to a control or test group. Test subjects were required to remove lenses daily after waking, clean them with the MPDS, and reinsert the lenses. Control subjects wore lenses without removal for 30 days extended wear. Handling-related lens contamination was assessed at the baseline visit. There was no significant difference between the test and control groups for the incidence of significant corneal infiltrative events (1.3 vs. 4.9%, p = 0.368), total corneal infiltrative events (2.6 vs. 4.9%, p = 0.682), or mechanical events (1.3 vs. 2.5%, p = 1.00). The test group had greater corneal staining (p lenses) resulted in isolation of Gram-positive bacteria from 92.5% of test lenses compared with 87.5% of control lenses (p = 0.712). Gram-negative bacteria were isolated from 5% of test subjects compared with 2.5% of control subjects (p = 1.00). Fungus was isolated from 2.5% of subjects in both the test and control groups (p = 1.00). The intervention of daily morning cleaning of the lens surface with an MPDS during extended wear did not significantly influence the incidence of adverse events.

  15. Air cleaning efficiency of deodorant materials under dynamic conditions: effect of air flow rate

    DEFF Research Database (Denmark)

    Mizutani, Chiyomi; Bivolarova, Mariya Petrova; Melikov, Arsen Krikor

    2014-01-01

    Unpleasant odor is a serious problem in hospitals and elderly facilities. One of the unpleasant odors is ammonia originating from human urine and sweat. The air cleaning efficiency of porous activated carbon fiber fabric which has been treated with acid, and porous activated carbon fiber fabric...... mixed with ammonia gas at a concentration of 20 ppm and velocities of 0.05, 0.15, 0.3 and 1.2 m/s. The activated carbon fibers treated with acid had a high deodorizing effect for ammonia (0.8) at a velocity of 0.05 m/s. The deodorizing effect of this material decreased with the increase in the velocity....... The porous activated carbon fiber fabric did not have a deodorant effect....

  16. Ultra-clean

    International Nuclear Information System (INIS)

    Hergenroether, K.

    1987-01-01

    No other method guarantees such a thorough cleaning of contaminated materials' surfaces. Only ultrasound can reach those cavities crevices and corners where any manual cleaning fails. Furthermore there is no cumbersome and time-consuming manual decontamination which often has to be carried out in glove boxes and hot cells. Depending on the design the cleaning effect can reach from removing adhering dirt particles to removing complete surface layers. (orig./PW) [de

  17. How Clean is Safe? Improving the Effectiveness of Decontamination of Structures and People Following Chemical and Biological Incidents

    Energy Technology Data Exchange (ETDEWEB)

    Vogt (Sorensen), B.M.

    2003-04-03

    This report describes a U.S. Department of Energy, (DOE) Chemical and Biological National Security Program project that sought to establish what is known about decontamination of structures, objects, and people following an exposure to chemical or biological materials. Specifically we sought to identify the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the factors determining when people were (or were not) decontaminated, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.

  18. A safe, effective, and facility compatible cleaning in place procedure for affinity resin in large-scale monoclonal antibody purification.

    Science.gov (United States)

    Wang, Lu; Dembecki, Jill; Jaffe, Neil E; O'Mara, Brian W; Cai, Hui; Sparks, Colleen N; Zhang, Jian; Laino, Sarah G; Russell, Reb J; Wang, Michelle

    2013-09-20

    Cleaning-in-place (CIP) for column chromatography plays an important role in therapeutic protein production. A robust and efficient CIP procedure ensures product quality, improves column life time and reduces the cost of the purification processes, particularly for those using expensive affinity resins, such as MabSelect protein A resin. Cleaning efficiency, resin compatibility, and facility compatibility are the three major aspects to consider in CIP process design. Cleaning MabSelect resin with 50mM sodium hydroxide (NaOH) along with 1M sodium chloride is one of the most popular cleaning procedures used in biopharmaceutical industries. However, high concentration sodium chloride is a leading cause of corrosion in the stainless steel containers used in large scale manufacture. Corroded containers may potentially introduce metal contaminants into purified drug products. Therefore, it is challenging to apply this cleaning procedure into commercial manufacturing due to facility compatibility and drug safety concerns. This paper reports a safe, effective and environmental and facility-friendly cleaning procedure that is suitable for large scale affinity chromatography. An alternative salt (sodium sulfate) is used to prevent the stainless steel corrosion caused by sodium chloride. Sodium hydroxide and salt concentrations were optimized using a high throughput screening approach to achieve the best combination of facility compatibility, cleaning efficiency and resin stability. Additionally, benzyl alcohol is applied to achieve more effective microbial control. Based on the findings, the recommended optimum cleaning strategy is cleaning MabSelect resin with 25 mM NaOH, 0.25 M Na2SO4 and 1% benzyl alcohol solution every cycle, followed by a more stringent cleaning using 50 mM NaOH with 0.25 M Na2SO4 and 1% benzyl alcohol at the end of each manufacturing campaign. A resin life cycle study using the MabSelect affinity resin demonstrates that the new cleaning strategy

  19. Effect of sponge ball cleaning on removing vernacles in condenser tubes

    International Nuclear Information System (INIS)

    Mimura, Keisuke; Minamoto, Kenju; Kyohara, Shigeru

    1977-01-01

    Usually aluminum brass material is adopted for the condenser tubes in thermal and nuclear power stations today, and sea water is treated with chlorine for the purpose of smooth operation and maintenance, but recently, this treatment tends to be avoided in view of environment preservation. When the chlorine treatment is not carried out, vernacles and other marine living things adhere to the internal surfaces of condenser tubes, and the corrosion of the tubes and the lowering of heat transfer rate occur. In this study, sponge ball cleaning was selected as the method of mechanically removing the adhering living things in tubes. When the balls are used too frequently, the formation of protective film is hindered, and the corrosion of tubes is accelerated, therefore it is important to determine the optimal frequency. The model condenser test and the immersion test of aluminum brass and titanium tubes were carried out. The testing method, the operation record and the test results are reported. Vernacles are apt to adhere to titanium tubes rather than aluminum brass tubes, and in case of aluminum brass tubes, they adhere to those with iron hydroxide film rather than those as manufactured. Vernacles adhere more as the flow speed in tubes is lower and the number of larvae in water is more. It was confirmed that the sponge ball cleaning was extremely effective for removing vernacles. (Kako, I.)

  20. Effect of sponge ball cleaning on removing vernacles in condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Mimura, K; Minamoto, K; Kyohara, S [Kobe Steel Ltd. (Japan)

    1977-01-01

    Usually aluminum brass material is adopted for the condenser tubes in thermal and nuclear power stations today, and sea water is treated with chlorine for the purpose of smooth operation and maintenance, but recently, this treatment tends to be avoided in view of environment preservation. When the chlorine treatment is not carried out, vernacles and other marine living things adhere to the internal surfaces of condenser tubes, and the corrosion of the tubes and the lowering of heat transfer rate occur. In this study, sponge ball cleaning was selected as the method of mechanically removing the adhering living things in tubes. When the balls are used too frequently, the formation of protective film is hindered, and the corrosion of tubes is accelerated, therefore it is important to determine the optimal frequency. The model condenser test and the immersion test of aluminum brass and titanium tubes were carried out. The testing method, the operation record and the test results are reported. Vernacles are apt to adhere to titanium tubes rather than aluminum brass tubes, and in case of aluminum brass tubes, they adhere to those with iron hydroxide film rather than those as manufactured. Vernacles adhere more as the flow speed in tubes is lower and the number of larvae in water is more. It was confirmed that the sponge ball cleaning was extremely effective for removing vernacles.

  1. Standard Test Method for Effects of Cleaning and Chemical Maintenance Materials on Painted Aircraft Surfaces

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers determination of the effects of cleaning solutions and liquid cleaner concentrates on painted aircraft surfaces (Note 1). Streaking, discoloration, and blistering may be determined visually. Softening is determined with a series of specially prepared pencils wherein determination of the softest pencil to rupture the paint film is made. Note 1—This test method is applicable to any paint film that is exposed to cleaning materials. MIL-PRF-85285 has been selected as a basic example. When other paint finishes are used, refer to the applicable material specification for panel preparation and system curing prior to testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  2. Experiments on cleaning effects of TDC, GDC and ECR-DC in the JFT-2M tokamak

    International Nuclear Information System (INIS)

    Matsuzaki, Y.; Ogawa, H.; Miura, Y.; Ohtsuka, H.; Suzuki, N.; Yamauchi, T.; Tani, T.; Mori, M.

    1987-01-01

    The cleaning effects of Taylor-type discharge cleaning (TDC), glow discharge cleaning (GDC) and ECR discharge cleaning (ECR-DC) were studied in the JFT-2M tokamak by comparing the properties of resulting tokamak plasmas, by observing the surface composition of samples and by residual gas analysis. The operational parameters of the three discharge cleaning techniques were as follows; the plasma current for TDC is 20 kA, the DC current for GDC is 3 A and the RF power for ECR-DC is 2.3 kW. Parameters of the tokamak plasmas such as loop voltages, radiation losses, spectra emission of oxygen, maximum mean electron densities and profiles of electron temperature were improved as the TDC and ECR-DC proceeded. Changes in the surface composition of samples were measured by Auger electron spectrosopy. The results showed that during the TDC and ECR-DC oxygen was reduced, while GDC reduced mainly carbon. Residual gas analysis performed during discharge cleaning corroborated these results. (orig.)

  3. Effects of dust accumulation and module cleaning on performance ratio of solar rooftop system and solar power plants

    Science.gov (United States)

    Sakarapunthip, Nattakarn; Chenvidhya, Dhirayut; Chuangchote, Surawut; Kirtikara, Krissanapong; Chenvidhya, Tanokkorn; Onreabroy, Wandee

    2017-08-01

    Thailand is an agricultural country, with rice, sugar, and cassava as the major export products. Production of rice, sugar cane, and cassava entails agricultural activities that give rise to significant airborne dusts. In this work, five photovoltaic (PV) units (one solar rooftop and four power plants) are selected for the study. From the study of dust accumulation on glass surface located near rice farms, it was found that opaque areas due to the deposition of dust are 11-14% after 1-2-week exposure. As a consequence, PV system performance is affected. Performance ratio was calculated to determine these effects. Overall results reveal that during the dry and hot seasons, dust deposition significantly affects the performance ratio. The performance ratio reduces by 1.6-3% for 1-month dust accumulation and reduces by 6-8% for 2-month dust accumulation. After cleaning the dust accumulated, the performance ratio greatly increases, resulting in the increase in the energy output by 10%. This increase provides economic and cost benefits of PV cleaning. The performance ratio is not significantly changed during the rainy season, which PV modules are relatively clean as the dust is washed away by rain. It was also found that most of the solar power plants in Thailand still rely on manual cleaning of PV modules with washing water followed by wiping. However, only one power plant, employs a machine for cleaning, resulting in lower cleaning costs.

  4. Effect of design and technology on the efficiency of ultrasonic facilities for sheet cleaning

    International Nuclear Information System (INIS)

    Lubyanitskij, G.D.

    1977-01-01

    Various techniques are reviewed for enhancing the efficiency of ultrasonic cleaning of various items, such as sheets, and for lowering the energy consumption of the process. It is important to maintain a specified spacing between the item to be cleaned and the supersound projector, to remove the contaminants accumulating in the surface layer of the solution and to provide an adequate combination between the ultrasonic and the mechanical cleaning means. It is noted that the injection of the surfactants directly into the cleaning zone lowers the intensity of foaming without affecting the quality of cleaning. In some cases the cleaning is even speeded up due to an improvement in conditions for the transmission of acoustic waves in areas at some distance from the converter

  5. Emerging sustainable/green cleaning products: health and environmental risks

    OpenAIRE

    Aydin, Mehmet Cihan; Işik, Ercan; Ulu, Ali Emre

    2016-01-01

    Sustainable development aims to bring a new perspective to our lives without compromising customer needs and quality. Along with sustainable development many innovative solutions came out. One of them is sustainable green cleaning products and techniques. Today, emissions from conventional cleaning products may cause severe health and environmental issues. Especially sick building syndromes such as eye, skin and respiratory irritations are main health effects of them. They may also contrib...

  6. Limonene and tetrahydrofurfuryl alcohol cleaning agent

    Science.gov (United States)

    Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.

    1996-05-07

    The present invention is a tetrahydrofurfuryl alcohol and limonene or terpineol cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  7. Limonene and tetrahydrofurfurly alcohol cleaning agent

    Science.gov (United States)

    Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.

    1997-10-21

    The present invention is a tetrahydrofurfuryl alcohol and limonene cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  8. Effect of capacity building programme of development agencies on ...

    African Journals Online (AJOL)

    Effect of capacity building programme of development agencies on well being of beneficiaries in Niger Delta, Nigeria. ... available for training. Adequate supervision will also go a long way to ensuring sustainability of the programmes. Key words: capacity building programme, development agencies, well being, beneficiaries ...

  9. Programmed Cleaning and Environmental Sanitation.

    Science.gov (United States)

    Gardner, John C., Ed.

    Maintenance of sanitation in buildings, plants, offices, and institutions; the selection of cleaning materials for these purposes; and the organization and supervision of the cleaning program are becoming increasingly complex and needful of a higher cost of handling. This book describes these problems and gives helpful information and guidance for…

  10. Cleaning Effectiveness of a Reciprocating Single-file and a Conventional Rotary Instrumentation System.

    Science.gov (United States)

    de Carvalho, Fredson Marcio Acris; Gonçalves, Leonardo Cantanhede de Oliveira; Marques, André Augusto Franco; Alves, Vanessa; Bueno, Carlos Eduardo da Silveira; De Martin, Alexandre Sigrist

    2016-01-01

    To compare cleaning effectiveness by histological analysis of a reciprocating single-file system with ProTaper rotary instruments during the preparation of curved root canals in extracted teeth. A total of 40 root canals with curvatures ranging between 20 - 40 degrees were divided into two groups of 20 canals. Canals were prepared to the following apical sizes: Reciproc size 25 (n=20); ProTaper: F2 (n=20). The normal distribution of data was tested by the Kolmogorov-Smirnov test and the values obtained for the test (Mann-Whitney U test, P .05) between the two groups. The application of reciprocating motion during instrumentation did not result in increased debris when compared with continuous rotation motion, even in the apical part of curved canals. Both instruments resulted in debris in the canal lumen, irrespective of the movement kinematics applied.

  11. Meissner effect in clean proximity-contact N-S double layer

    International Nuclear Information System (INIS)

    Higashitani, S.; Nagai, K.

    1994-01-01

    The Meissner effect in proximity-contact normal-superconducting (N-S) double layers is discussed in the clean limit. We obtain the quasi-classical Green's function linear in the vector potential such that satisfies the boundary conditions at the layer ends and also at the N-S interface with a finite reflection coefficient R. We find that, when there is no pairing interaction in the normal layer, the diamagnetic current in the normal layer is constant in space, consequently the magnetic field decreases linearly in the normal layer. To compare our theory with experiments, we calculate the screening length and find a good agreement in the temperature dependence with the experiments in the Au-Nb system. (orig.)

  12. Introduction of Small Advertising Cleaning Machine and Its Cleaning Effect Experiments in Beijing%北京市小广告清理设备介绍及清理效果试验

    Institute of Scientific and Technical Information of China (English)

    胡昌夏; 王晓燕; 孙晨阳; 冯伟

    2017-01-01

    对北京市各类小广告清理设备进行了简要介绍,并针对目前广泛使用的移动式小广告清理设备的清理效果进行了试验,在此基础上,对小广告清理设备的选择提出适宜推广使用汽车二类底盘车载小广告清理设备,高压热水清理适应范围最广并且清理效果综合较优,应该作为小广告清理的主要手段.%All kinds of small advertising cleaning machines in Beijing were introduced briefly.Based on the cleaning effect experiment results of small advertising cleaning mobile machines,we offered recornmendatiom on the type selection of the machines that it is suitable for the promotion of the use of two types of chassis car small advertising cleaning equipment;high pressure water cleaning adapts to the widest range and the best comprehensive effect of cleaning,then it should be used as the main means of small advertisements to clean up.

  13. The CLEAN Workshop Series: Promoting Effective Pedagogy for Teaching Undergraduate Climate Science

    Science.gov (United States)

    Kirk, K. B.; Bruckner, M. Z.; Manduca, C. A.; Buhr, S. M.

    2012-12-01

    To prepare students to understand a changing climate, it is imperative that we equip educators with the best possible tools and methods for reaching their audience. As part of the Climate Literacy and Energy Awareness Network (CLEAN) professional development efforts, two workshops for undergraduate faculty were held in 2012. These workshops used a variety of activities to help faculty learn about recent climate research, take part in demonstrations of successful activities for teaching climate topics, and collaborate to create new teaching materials. The workshops also facilitated professional networking among participants. Both workshops were held online, eliminating the need for travel, encouraging participants without travel funds to attend, and allowing international collaborations and presentations. To create an authentic experience, the workshop used several technologies such as the Blackboard Collaborate web conferencing platform, SERC's web-based collaboration tools and online discussion threads, and conference calls. The workshop Communicating Climate Science in the Classroom, held in April 2012, explored practices for communicating climate science and policy in the classroom and provided strategies to improve student understanding of this complex and sensitive topic. Workshop presentations featured public opinion research on Americans' perceptions of climate change, tactics for identifying and resolving student misconceptions, and methods to address various "backfire effects" that can result from attempts to correct misinformation. Demonstrations of teaching approaches included a role-playing simulation of emissions negotiations, Princeton's climate stabilization wedges game, and an activity that allows students to use scientific principles to tackle misinformation. The workshop Teaching Climate Complexity was held in May 2012. Teaching the complexities of climate science requires an understanding of many facets of the Earth system and a robust pedagogic

  14. Effectiveness of cleaning-disinfection wipes and sprays against multidrug-resistant outbreak strains

    NARCIS (Netherlands)

    Kenters, N.; Huijskens, E.G.; Wit, S.C.J. de; Rosmalen, J. van; Voss, A.

    2017-01-01

    BACKGROUND: Hospital rooms play an important role in the transmission of several health care-associated pathogens. During the last few years, a number of innovative cleaning-disinfecting products have been brought to market. In this study, commercially available products combining cleaning and

  15. ALGORITHM OF SELECTION EFFECTIVE SOLUTIONS FOR REPROFILING OF INDUSTRIAL BUILDINGS

    Directory of Open Access Journals (Sweden)

    MENEJLJUK A. I.

    2016-08-01

    Full Text Available Raising of problem.Non-compliance requirements of today's industrial enterprises, which were built during the Soviet period, as well as significant technical progress, economic reform and transition to market principles of performance evaluation leading to necessity to change their target and functionality. The technical condition of many industrial buildings in Ukraine allows to exploit them for decades.Redesigning manufacturing enterprises allows not only to reduce the cost of construction, but also to obtain new facilities in the city. Despite the large number of industrial buildings that have lost their effectiveness and relevance, as well as a significant investor interest in these objects, the scope of redevelopment in the construction remains unexplored. Analysis researches on the topic. The problem of reconstruction of industrial buildings considered in Topchy D. [3], Travin V. [9], as well as in the work of other scientists. However, there are no rules in regulatory documents and system studies for improving the organization of the reconstruction of buildings at realigning. The purpose of this work is the development an algorithm of actions for selection of effective organizational decisions at the planning stage of a reprofiling project of industrial buildings. The proposed algorithm allows you to select an effective organizational and technological solution for the re-profiling of industrial buildings, taking into account features of the building, its location, its state of structures and existing restrictions. The most effective organizational solution allows realize the reprofiling project of an industrial building in the most possible short terms and with the lowest possible use of material resources, taking into account the available features and restrictions. Conclusion. Each object has a number of unique features that necessary for considering at choosing an effective reprofiling variant. The developed algorithm for selecting

  16. Building Effective Water Governance in the Asian Highlands | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Building Effective Water Governance in the Asian Highlands ... This project is funded through IDRC's Adaptation Research Initiative in Asia (ARI-Asia) ... Kunming Institute of Botany, Chinese Academy of Sciences as represented by Sun Hang.

  17. Effect of capacity building on organizational performance of ...

    African Journals Online (AJOL)

    Effect of capacity building on organizational performance of multipurpose ... is need for re-orientation and sensitization of members and the employees of the ... assist by making cooperative extension services compulsory and accessible to all ...

  18. Trust-Building in Electronic Markets: Relative Importance and Interaction Effects of Trust-Building Mechanisms

    Science.gov (United States)

    Tams, Stefan

    We examine the relative and complementary effectiveness of trust-building strategies in online environments. While prior research has examined various antecedents to trust, we investigated two trust-building mechanisms more in depth: Web site trust and vendor reputation. We tried to understand the relative effectiveness of these two important mechanisms to provide online businesses with a clear recommendation of how to establish trust in an effective and efficient manner. Drawing from the literature on trust, we proposed vendor reputation to be more effective than Web site trust. Moreover, we examined a potential complementary effect of these mechanisms so as to provide online businesses with a deeper understanding of how to derive superior trust. We hypothesize a small such effect. The study proposes a laboratory experiment to test the model.

  19. Estimating bounds on the macroeconomic effects of the Clean Energy Future policy scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Sanstad, A. H.; DeCanio, S. J.; Boyd, G. A.

    2000-04-04

    The Clean Energy Future (CEF) is a partial equilibrium study in that it focuses specifically on markets for energy services. It is also important, however, to consider potential effects of the CEF policies on overall economic performance. The purpose of this paper is: (1) to provide a framework for interpreting the macroeconomic (or second-order) effects that might occur under the types of scenarios analyzed in the CEF, and (2) to obtain a range of estimates of these effects associated with the Moderate and Advanced scenarios as described in the CEF study. In this paper the authors consider results from both types of model in the context of the CEF study. The primary framework and calculations focus on the second meaning given above of the term macroeconomic and the associated CGE models, because these are appropriate for analysis on the time scales of the CEF, through 2010 or 2020. Because the Keynesian-style macroeconomic models are designed and suited for short-term forecasting, they also discuss the application of one such model to the analysis of the shorter-horizon effects of certain policies to reduce carbon emissions.

  20. CLEANING OF FRENCH SITES

    CERN Multimedia

    Mauro Nonis

    2002-01-01

    In the last two weeks some cleaning problems have been remarked in several CERN buildings on the French part of CERN sites. This is mainly due to the start up of the new cleaning contract from the 1st July. These problems are not related to a budgetary reduction of the activity. We excuse for the malfunctions that have been created to CERN community and we assure you that we have taken all the needed measures to solve the problem in the shortest delay. Mauro Nonis (ST/FM)

  1. Changes in knowledge and attitudes of hospital environmental services staff: The Researching Effective Approaches to Cleaning in Hospitals (REACH) study.

    Science.gov (United States)

    Mitchell, Brett G; White, Nicole; Farrington, Alison; Allen, Michelle; Page, Katie; Gardner, Anne; Halton, Kate; Riley, Thomas V; Gericke, Christian A; Paterson, David L; Graves, Nicholas; Hall, Lisa

    2018-03-14

    The Researching Effective Approaches to Cleaning in Hospitals (REACH) study tested a multimodal cleaning intervention in Australian hospitals. This article reports findings from a pre/post questionnaire, embedded into the REACH study, that was administered prior to the implementation of the intervention and at the conclusion of the study. A cross-sectional questionnaire, nested within a stepped-wedge trial, was administered. The REACH intervention was a cleaning bundle comprising 5 interdependent components. The questionnaire explored the knowledge, reported practice, attitudes, roles, and perceived organizational support of environmental services staff members in the hospitals participating in the REACH study. Environmental services staff members in 11 participating hospitals completed 616 pre- and 307 post-test questionnaires (n = 923). Increases in knowledge and practice were seen between the pre-and post-test questionnaires. Minimal changes were observed in attitudes regarding the role of cleaning and in perceived organizational support. To our knowledge, this is the first study to report changes in knowledge, attitudes, and perceived organizational support in environmental services staff members, in the context of a large multicenter clinical trial. In this underexplored group of hospital workers, findings suggest that environmental services staff members have a high level of knowledge related to cleaning practices and understand the importance of their role. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Effect of ammonia on ozone-initiated formation of indoor secondary products with emissions from cleaning products

    Science.gov (United States)

    Huang, Yu; Lee, Shun Cheng; Ho, Kin Fai; Ho, Steven Sai Hang; Cao, Nanying; Cheng, Yan; Gao, Yuan

    2012-11-01

    Biogenic volatile organic compounds (BVOCs) emitted from cleaning products and air fresheners indoors are prone to oxidation resulting in the formation of secondary pollutants that can pose health risks on residents. Ammonia (NH3) is ubiquitous in ambient and indoor environments. In this study, we investigated the effect of ammonia (NH3) on secondary pollutants formation from the ozonolysis of BVOCs emitted from cleaning products including floor cleaner (FC), kitchen cleaner (KC) and dishwashing detergent (DD) in a large environmental chamber. Our results demonstrated that the presence of NH3 (maximum concentration is 240 ppb) could significantly enhance secondary organic aerosols (SOAs) formation from the ozonolysis of all the three categories of cleaning products. For example, for the FC sample, the maximum total particle concentration was up to 2.0 × 104 # cm-3 in the presence of NH3, while it was 1.3 × 104 # cm-3 which was 35% lower without NH3. However, it was found that the extent of NH3 effect on SOAs formation from the ozonolysis of BVOCs emissions was component-dependent. The presence of NH3 in the reaction systems could increase the consumptions of d-limonene that is the dominant BVOC species as identified in cleaning products. The percent yields (%) of secondary carbonyl compounds generated from the ozonolysis of BVOCs emitted from three categories of cleaning products were identified in the presence and absence of NH3, respectively. The increase in SOAs particle number concentration can be attributed to the formation of condensable salts from reactions between NH3 and organic compounds generated from the BVOCs ozonolysis processes. By investigating the NH3 effect on the ozonolysis of BVOCs mixtures in contrast to the chemistry of individual compounds, a better assessment can be made of the overall impact cleaning products have on real indoor environments.

  3. Assessment of test methods for evaluating effectiveness of cleaning flexible endoscopes.

    Science.gov (United States)

    Washburn, Rebecca E; Pietsch, Jennifer J

    2018-06-01

    Strict adherence to each step of reprocessing is imperative to removing potentially infectious agents. Multiple methods for verifying proper reprocessing exist; however, each presents challenges and limitations, and best practice within the industry has not been established. Our goal was to evaluate endoscope cleaning verification tests with particular interest in the evaluation of the manual cleaning step. The results of the cleaning verification tests were compared with microbial culturing to see if a positive cleaning verification test would be predictive of microbial growth. This study was conducted at 2 high-volume endoscopy units within a multisite health care system. Each of the 90 endoscopes were tested for adenosine triphosphate, protein, microbial growth via agar plate, and rapid gram-negative culture via assay. The endoscopes were tested in 3 locations: the instrument channel, control knob, and elevator mechanism. This analysis showed substantial level of agreement between protein detection postmanual cleaning and protein detection post-high-level disinfection at the control head for scopes sampled sequentially. This study suggests that if protein is detected postmanual cleaning, there is a significant likelihood that protein will also be detected post-high-level disinfection. It also infers that a cleaning verification test is not predictive of microbial growth. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. DESIGNING AND EFFICIENCY EFFECT OF AUTOMATIC BALL-CLEANING SYSTEM FOR CONDENSER 180-KTsS-1 OF TURBINE Т-180/210-130-1 LMZ. Part 2

    Directory of Open Access Journals (Sweden)

    Yu. A. Zenovich-Leshkevich-Ol’pinskiy

    2015-01-01

    Full Text Available The authors elaborate the economical efficiency evaluation technique that could be universal and applied for technical-and-economic feasibility study of the ball-cleaning system installation on the steam turbines of the electric power plants. Besides the effect from reducing the exhaust steam pressure in the condenser by means of the ball-cleaning system implementation, this technique also accounts for the effect of lowering the condenser hydraulic pressure.The article refers to the practical results of the ball-cleaning system introduction on the steam turbines of Gomel CHP-2. As a result of regular application of the ball-cleaning system the temperature difference of the condensers of all blocks Т-180/210-130-1 confined into the regulatory values and the cleanness coefficient of all three turbine units reached 0,85. The authors consider the working results, implementation experience of the ball-cleaning system at Gomel CHP-2 and its efficiency evaluation technique to be worth disseminating when introducing the analogous systems at the plants of Belarusian power network.The authors suggest measures on the condenser automatic-cleaning system improvement with the turbine mathematical-simulation model employment that will make it possible to optimize the condenser cleaning regimes and to increase the ball-cleaning system effectiveness with the condenser cleanness coefficient growing up to 0,90–0,92.

  5. FAILURE MODE EFFECTS AND CRITICALITY ANALYSIS (FMECA AS A QUALITY TOOL TO PLAN IMPROVEMENTS IN ULTRASONIC MOULD CLEANING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Cristiano Fragassa

    2016-12-01

    Full Text Available Inside the complex process used for tire production, ultrasonic cleaning treatment probably represents the best solution to preserve the functionality of tire moulds, by removing residuals from moulds and keeping an unaltered quality for their surfaces. Ultrasonic Mould Cleaning Systems (UMCS is, however, a complicated technology that combines ultrasonic waves, high temperature and a succession of acid and basic attacks. At the same time, an UMCS plant, as part of a long productive chain, has to guarantee the highest productivity reducing failures and maintenances. This article describes the use of Failure Mode Effects and Criticality Analysis (FMECA as a methodology for improving quality in cleaning process. In particular, FMECA was utilized to identify potential defects in the original plant design, to recognize the inner causes of some failures actually occurred during operations and, finally, to suggest definitive re-design actions. Changes were implemented and the new UMCS offers a better quality in term of higher availability and productivity.

  6. Effective technology of wood and gaseous fuel co-firing for clean energy production

    International Nuclear Information System (INIS)

    Zake, M.; Barmina, I.; Gedrovics, M.; Desnickis, A.

    2007-01-01

    The main aim of the study was to develop and optimise a small-scale experimental co-firing technique for the effective and clean heat energy production by replacing a proportion of fossil fuel (propane) with renewable one (wood biomass). Technical solutions of propane co-fire presenting two different ways of additional heat supply to the wood biomass are proposed and analysed. The experiments have shown that a better result can be obtained for the direct propane co-fire of the wood biomass, when the rate of wood gasification and the ignition of volatiles are controlled by additional heat energy supply to the upper portion of wood biomass. A less effective though cleaner way of heat energy production is the direct propane co-fire of volatiles when low-temperature self-sustaining burnout of the wood biomass controls the rate of the volatile formation, while additional heat energy supply to the flow of volatiles controls their burnout. The effect of propane co-fire on the heat production rate and the composition of polluting emissions is studied and analysed for different rates of the additional heat supply to the wood biomass and of the swirling air supply as well as for different charge of wood biomass above the inlet of the propane flame flow. (Authors)

  7. Risk in cleaning: chemical and physical exposure.

    Science.gov (United States)

    Wolkoff, P; Schneider, T; Kildesø, J; Degerth, R; Jaroszewski, M; Schunk, H

    1998-04-23

    Cleaning is a large enterprise involving a large fraction of the workforce worldwide. A broad spectrum of cleaning agents has been developed to facilitate dust and dirt removal, for disinfection and surface maintenance. The cleaning agents are used in large quantities throughout the world. Although a complex pattern of exposure to cleaning agents and resulting health problems, such as allergies and asthma, are reported among cleaners, only a few surveys of this type of product have been performed. This paper gives a broad introduction to cleaning agents and the impact of cleaning on cleaners, occupants of indoor environments, and the quality of cleaning. Cleaning agents are usually grouped into different product categories according to their technical functions and the purpose of their use (e.g. disinfectants and surface care products). The paper also indicates the adverse health and comfort effects associated with the use of these agents in connection with the cleaning process. The paper identifies disinfectants as the most hazardous group of cleaning agents. Cleaning agents contain evaporative and non-evaporative substances. The major toxicologically significant constituents of the former are volatile organic compounds (VOCs), defined as substances with boiling points in the range of 0 degree C to about 400 degrees C. Although laboratory emission testing has shown many VOCs with quite different time-concentration profiles, few field studies have been carried out measuring the exposure of cleaners. However, both field studies and emission testing indicate that the use of cleaning agents results in a temporal increase in the overall VOC level. This increase may occur during the cleaning process and thus it can enhance the probability of increased short-term exposure of the cleaners. However, the increased levels can also be present after the cleaning and result in an overall increased VOC level that can possibly affect the indoor air quality (IAQ) perceived by

  8. The effectiveness of three home products in cleaning and disinfection of Staphylococcus aureus and Escherichia coli on home environmental surfaces.

    Science.gov (United States)

    Goodyear, N; Brouillette, N; Tenaglia, K; Gore, R; Marshall, J

    2015-11-01

    The objectives of this study were to investigate three products for: (i) cleaning effectiveness on two common household surfaces, and (ii) disinfection effectiveness against two common bacteria. Products included conventional ('bleach'), environmentally preferable (EP), do-it-yourself (DIY: distilled white vinegar, club soda, tea tree oil), 24-h old DIY, and individual DIY components in dilution. For cleaning ceramic, no product was effective (≥85% removal of Hucker's soil), however, DIY performed better than EP and bleach. On stainless, only DIY failed to meet the standard. For disinfection, bleach and EP achieved ≥5·00 log10 reductions under all conditions. DIY and components were more active against Escherichia coli than Staphylococcus aureus but only fresh DIY and 50% vinegar achieved ≥5·00 log10 reductions. EP is an effective alternative to bleach. DIY may be an adequate alternative for cleaning ceramic and for household use, where complete elimination of micro-organisms is unnecessary; however, it must be freshly prepared each day. This is the first report of performance of purportedly safer alternatives for both cleaning and disinfection for use in home health care. The EP product and DIY are potential alternatives for some household uses. © 2015 The Society for Applied Microbiology.

  9. Survival of Salmonella Copenhagen in food bowls following contamination with experimentally inoculated raw meat: Effects of time, cleaning, and disinfection

    OpenAIRE

    Weese, J Scott; Rousseau, J.

    2006-01-01

    There are concerns regarding the safety of feeding raw meat to household pets. This study demonstrated that Salmonella persists in food bowls that are inoculated with Salmonella-containing raw meat. Standard methods of cleaning and disinfection were minimally effective at eliminating Salmonella contamination.

  10. Building effective R&D capabilities abroad.

    Science.gov (United States)

    Kuemmerle, W

    1997-01-01

    In the past, companies kept most of their research and development activities in their home country because they thought it important to have R&D close to where strategic decisions were being made. But today many companies choose to establish R&D networks in foreign countries in order to tap the knowledge there or to commercialize products for those markets at a competitive speed. Adopting a global approach entails new, complex managerial challenges. It means linking R&D strategy to a company's overall business strategy. The first step in adopting such an approach is to build a team to lead the initiative--a team whose members are sufficiently senior to be able to mobilize resources at short notice. Second, companies must determine whether an R&D site's primary objective is to augment the expertise that the home base has the offer or to exploit that knowledge for use in the foreign country. That determination affects the choice of location and staff. For example, to augment the home base laboratory, a company would want to be near a foreign university; to exploit the home base laboratory it would need to be near large markets and manufacturing facilities. The best individual for managing both types of site combines the qualities of good scientist and good manager, knows how to integrate the new site with existing sites, understand technology trends, and is good at gaining access to foreign scientific communities. As more pockets of knowledge emerge around the globe and competition in foreign markets mounts, only those companies that embrace an informed approach to global R&D will be able to meet the new challenges.

  11. Heavy components coupling effect on building response spectra generation

    International Nuclear Information System (INIS)

    Liu, T.H.; Johnson, E.R.

    1985-01-01

    This study investigates the dynamic coupling effect on the floor response spectra between the heavy components and the Reactor Interior (R/I) building in a PWR. The following cases were studied: (I) simplified models of one and two lump mass models representing building and heavy components, and (II) actual plant building and heavy component models. Response spectra are developed at building nodes for all models, using time-history analysis methods. Comparisons of response spectra from various models are made to observe the coupling effects. In some cases, this study found that the coupling would reduce the response spectra values in certain frequency regions even if the coupling is not required according to the above criteria. (orig./HP)

  12. Effectiveness of clean-up procedures on stain susceptibility of different orthodontic adhesives

    Directory of Open Access Journals (Sweden)

    Swati Pundlik Mane

    2014-01-01

    Conclusion: Chemical-cure adhesive showed higher stain susceptibility than light-cure adhesive in all clean-up procedures. Both adhesives would show less stain susceptibility with polishing step with rubber cup and pumice.

  13. Effect of hang cleans or squats paired with countermovement vertical jumps on vertical displacement.

    Science.gov (United States)

    Andrews, Tedi R; Mackey, Theresa; Inkrott, Thomas A; Murray, Steven R; Clark, Ida E; Pettitt, Robert W

    2011-09-01

    Complex training is characterized by pairing resistance exercise with plyometric exercise to exploit the postactivation potentiation (PAP) phenomenon, thereby promising a better training effect. Studies on PAP as measured by human power performances are equivocal. One issue may be the lack of analyses across multiple sets of paired exercises, a common practice used by athletes. We evaluated countermovement vertical jump (CMJ) performance in 19 women, collegiate athletes in 3 of the following trials: (a) CMJs-only, where 1 set of CMJs served as a conditioning exercise, (b) heavy-load, back squats paired with CMJs, and (c) hang cleans paired with CMJs. The CMJ vertical displacement (3-attempt average), as measured with digital video, served as the dependent variable of CMJ performance. Across 3 sets of paired-exercise regimens, CMJ-only depreciated 1.6 cm and CMJ paired with back squats depreciated 2.0 cm (main effect, p squats or CMJs in and of themselves. Future research on exercise modes of complex training that best help athletes preserve and train with the highest power possible, in a given training session, is warranted.

  14. Design, build, and test an air-cleaning system for working-level control in uranium mines. Open file report October 1979-April 1984

    International Nuclear Information System (INIS)

    Schroeder, W.E.; Muldoon, T.L.; Babbitt, C.

    1984-06-01

    The health hazard from 222 radon byproducts, radon daughters, will be increasingly difficult to control by dilution with primary ventilation as the uranium industry digs farther and deeper for ore of diminishing grade. One solution is removal of daughters from air at the work place by filtering out respirable-size dust particles to which most daughters attach. This report describes design and testing of a filtration unit that reduces the working level in ventilating air 95% on an airflow of 10,000 cfm. Buildup of dust on the filter is controlled by periodic back-pulsing, so that the unit can operate for an extended period without changing elements. The effectiveness of the self-cleaning action was satisfactory under a contaminant loading that was 43% diesel smoke. Back-pulsing was able to control filter loading or buildup to a degree even under 100% diesel. The report describes testing of the filter medium and filter unit in both an experimental and an active mine and concludes with an analysis of the prototype design

  15. Can the Clean Development Mechanism attain both cost-effectiveness and sustainable development objectives?

    International Nuclear Information System (INIS)

    Kolshus, Hans H; Vevatne, Jonas; Torvanger, Asbjoern; Aunan, Kristin

    2001-06-01

    The Clean Development Mechanism (CDM), as defined in the Kyoto Protocol, has two objectives: to promote sustainable development in host developing countries, and to improve global cost-effectiveness by assisting developed countries in meeting their Kyoto targets. The aim of this paper is to explore the background of the CDM and discuss to what extent its current design allows it to achieve its dual objective. The first part of the paper is a literature review that includes descriptions of the flexibility mechanisms under the Kyoto Protocol; the CDM's market potential, and the issues of cost-effectiveness and sustainable development. In the second part of the paper, we discuss to what extent there is a conflict between cost-effectiveness and sustain ability, and whether the two objectives of the CDM can be achieved simultaneously. We develop a set of indicators to evaluate non-carbon benefits of CDM projects on the environment, development, and. equity, and show how these indicators can be used in practice by looking at case studies of CDM project candidates in the energy sector from Brazil and China. We demonstrate that for some CDM projects there is a trade-off between cost-effectiveness, in terms of a low quota price, and a high score on sustain ability indicators. We have reason to believe that the size of the CDM market in some studies is over-estimated since transaction costs and the challenge of promoting sustainable development are not fully accounted for. Also, we find that the proposed set of indicators can be a necessary tool to assure that sustain ability impacts of CDM projects are taken into consideration. (author)

  16. Can the Clean Development Mechanism attain both cost-effectiveness and sustainable development objectives?

    Energy Technology Data Exchange (ETDEWEB)

    Kolshus, Hans H; Vevatne, Jonas; Torvanger, Asbjoern; Aunan, Kristin

    2001-06-01

    The Clean Development Mechanism (CDM), as defined in the Kyoto Protocol, has two objectives: to promote sustainable development in host developing countries, and to improve global cost-effectiveness by assisting developed countries in meeting their Kyoto targets. The aim of this paper is to explore the background of the CDM and discuss to what extent its current design allows it to achieve its dual objective. The first part of the paper is a literature review that includes descriptions of the flexibility mechanisms under the Kyoto Protocol; the CDM's market potential, and the issues of cost-effectiveness and sustainable development. In the second part of the paper, we discuss to what extent there is a conflict between cost-effectiveness and sustain ability, and whether the two objectives of the CDM can be achieved simultaneously. We develop a set of indicators to evaluate non-carbon benefits of CDM projects on the environment, development, and. equity, and show how these indicators can be used in practice by looking at case studies of CDM project candidates in the energy sector from Brazil and China. We demonstrate that for some CDM projects there is a trade-off between cost-effectiveness, in terms of a low quota price, and a high score on sustain ability indicators. We have reason to believe that the size of the CDM market in some studies is over-estimated since transaction costs and the challenge of promoting sustainable development are not fully accounted for. Also, we find that the proposed set of indicators can be a necessary tool to assure that sustain ability impacts of CDM projects are taken into consideration. (author)

  17. Effect of facade components on energy efficiency in office buildings

    International Nuclear Information System (INIS)

    Ihara, Takeshi; Gustavsen, Arild; Jelle, Bjørn Petter

    2015-01-01

    Highlights: • Investigation of facade properties for energy efficiency of Tokyo office buildings. • Higher reflectance for opaque parts may slightly reduce energy demand. • Lower window U-value and solar heat gain coefficient are potential solutions. • Decreased heating due to insulation did not always compensate increased cooling. • Fundamental data for adjustment of facade properties of buildings are provided. - Abstract: Properties of facade materials should be considered to determine which of them strongly affect building energy performance, regardless of the building shapes, scales, ideal locations, and building types, and thus may be able to promote energy efficiency in buildings. In this study, the effects of four fundamental facade properties related to the energy efficiency of office buildings in Tokyo, Japan, were investigated with the purpose of reducing the heating and cooling energy demands. Some fundamental design factors such as volume and shape were also considered. It was found that the reduction in both the solar heat gain coefficient and window U-value and increase in the solar reflectance of the opaque parts are promising measures for reducing the energy demand. Conversely, the reduction in the U-value of the opaque parts decreased the heating energy demand, and this was accompanied by an increase in the cooling energy demand in some cases because the total energy demands were predominantly for cooling. The above-mentioned promising measures for reducing building energy demands are thus recommended for use, and an appropriate U-value should be applied to the opaque parts based on careful considerations. This study provides some fundamental ideas to adjust the facade properties of buildings.

  18. Novel micronized woody biomass process for production of cost-effective clean fermentable sugars.

    Science.gov (United States)

    Fu, Yu; Gu, Bon-Jae; Wang, Jinwu; Gao, Johnway; Ganjyal, Girish M; Wolcott, Michael P

    2018-03-29

    Thermo-chemical pretreatments of biomass typically result in environmental impacts from water use and emission. The degradation byproducts in the resulting sugars can be inhibitory to the activities of enzymes and yeasts. The results of this study showed that combining existing commercial comminution technology can reduce total energy consumption with improved saccharification yield while eliminating chemical use. Impact mill was found to be the most efficient milling for size reduction of forest residual chips from ca. 2 mm to a specific value below 100 µm. The further micronization effectively disrupted the recalcitrance of the woody biomass and produced the highly saccharifiable substrates for downstream processing. In addition, extrusion can be integrated into a clean cellulosic sugar process for further fibrillation in place of the conventional mixing processing. The highest energy efficiency was observed on the impact-milled samples with 0.515 kg sugars kWh -1 . Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. The Effects of Psychosocial Factors on Work Accidents in Izmir Konak Municipality Cleaning Workers.

    Directory of Open Access Journals (Sweden)

    Aysun Akgun

    2010-12-01

    Full Text Available AIM: The aim of this cross-sectional study was to investigate the relationship between psychosocial factors and work accidents among waste collector workers in Izmir Konak Municipality Cleaning Services Section. The study consisted 92 (%68 out of 135 workers of those accepted to participation. METHOD: face-to-face questionnaire were administered for data collection. Dependent variable was the work-related accident for previous six months. Independent variables were sociodemographic features, working conditions, mental health status, daytime sleepiness, workload and social support. The chi-square test and the logistic regression models used for data analysis. RESULTS: Work accident prevalence was 32.6% for the last 6 months. Age and workload were significantly affected work-related accidents (p=0.03; p=0.01 respectively. Social support, mental health status and daytime sleepiness status did not effect work-related accident prevalence (p=0.48; p=0.21; p=0.30 respectively. CONCLUSION: Results of the study indicated that work-related accident prevalence is high among workers in Izmir Konak Municipality. Workload was found important risk factor for the work accident among waste collector workers. [TAF Prev Med Bull 2010; 9(6.000: 623-632

  20. General equilibrium effects of a supply side GHG mitigation option under the Clean Development Mechanism.

    Science.gov (United States)

    Timilsina, Govinda R; Shrestha, Ram M

    2006-09-01

    The Clean Development Mechanism (CDM) under the Kyoto Protocol to the United Nations Framework Convention on Climate Change is considered a key instrument to encourage developing countries' participation in the mitigation of global climate change. Reduction of greenhouse gas (GHG) emissions through the energy supply and demand side activities are the main options to be implemented under the CDM. This paper analyses the general equilibrium effects of a supply side GHG mitigation option-the substitution of thermal power with hydropower--in Thailand under the CDM. A static multi-sector general equilibrium model has been developed for the purpose of this study. The key finding of the study is that the substitution of electricity generation from thermal power plants with that from hydropower plants would increase economic welfare in Thailand. The supply side option would, however, adversely affect the gross domestic product (GDP) and the trade balance. The percentage changes in economic welfare, GDP and trade balance increase with the level of substitution and the price of certified emission reduction (CER) units.

  1. Sulfur dioxide emissions and market effects under the Clean Air Act Acid Rain Program

    International Nuclear Information System (INIS)

    Zipper, C.E.; Gilroy, L.

    1998-01-01

    The Clean Air Act Amendments of 1990 (CAAA90) established a national program to control sulfur dioxide (SO 2 ) emissions from electricity generation. CAAA90's market-based approach includes trading and banking of SO 2 -emissions allowances. The paper presents an analysis of data describing electric utility SO 2 emissions in 1995, the first year of the program's Phase I, and market effects over the 1990-95 period. Fuel switching and flue-gas desulfurization were the dominant means used in 1995 by targeted generators to reduce emissions to 51% of 1990 levels. Flue-gas desulfurization costs, emissions allowance prices, low-sulfur coal prices, and average sulfur contents of coals shipped to electric utilities declined over the 1990-95 period. Projections indicate that 13-15 million allowances will have been banked during the programs' Phase I, which ends in 1999, a quantity expected to last through the first decade of the program's stricter Phase II controls. In 1995, both allowance prices and SO 2 emissions were below pre-CAAA90 expectations. The reduction of SO 2 emissions beyond pre-CAAA90 expectations, combined with lower-than-expected allowance prices and declining compliance costs, can be viewed as a success for market-based environmental controls. 21 refs., 6 figs., 3 tabs

  2. Effect of mouth cleaning with hinokitiol-containing gel on oral malodor: a randomized, open-label pilot study.

    Science.gov (United States)

    Iha, Kosaku; Suzuki, Nao; Yoneda, Masahiro; Takeshita, Toru; Hirofuji, Takao

    2013-10-01

    The aim of the study was to evaluate the effect of mouth cleaning with hinokitiol-containing gel on oral malodor. An open-label, randomized, controlled trial was conducted to assess oral malodor and clinical parameters related to oral malodor before and after mouth cleaning with hinokitiol-containing gel (n = 9) or with gel not including hinokitiol (n = 9). Mouth cleaning included the teeth, gingiva, and tongue and was carried out 3 times per day for 4 weeks. Organoleptic test (OLT) scores (P = .021), levels of hydrogen sulfide (P = .008) and methyl mercaptan (P = .020), frequency of bleeding on probing, average probing pocket depth, and plaque index significantly improved in the group using hinokitiol. In contrast, only the OLT score (P = .031) significantly improved in the control group after the treatment regimen. Mouth cleaning with hinokitiol-containing gel may be effective for reduction of oral malodor. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Manufacturing of NAA laboratory clean room

    International Nuclear Information System (INIS)

    Suwoto; Hasibuan, Djaruddin

    2001-01-01

    The ''NAA laboratory clean room'' has been built in the Reactor Serba Guna G.A. Siwabessy building. The erection of ''AAN laboratory clean room'' doing by started of preparation of the ''manufacturing procedure'' refer to ''Design and manufacturing neutron activation analysis clean room laboratory''. Manufacturing process and erection doing refer to procedures makes. By providing of the ''AAN laboratory clean room'' can be cocluded that the research activity and the user sevises in P2TRR well meet to be done

  4. Diamond-cleaning investigations

    International Nuclear Information System (INIS)

    Derry, T.E.

    Four parcels of diamonds which either had or had not been cleaned using the usual techniques, chiefly involving etch in molten potassium nitrate were supplied by De Beers Diamond Research Laboratories. Each parcel contained about 40 stones, amounting to about 10 carats. Half the diamonds in each parcel were cleaned by a standard procedure involving half an hours ultrasonic agitation in a 20% solution of the commercial detergent 'Contrad' which is effectively a surfactant and chelating agent. Visual comparisons by a number of observers who were not told the stones' histories, established that these diamonds generally had a more sparkling appearance after the cleaning procedure had been applied

  5. Effective 226Ra-content of some Hungarian building materials

    International Nuclear Information System (INIS)

    Toth, A.; Feher, I.

    1976-01-01

    The aim of the work was to analyse the effective 226 Ra content of building- and back filling materials used in Hungary. The quantity of radon was determined by ionization chambers connected to vibrating-reed electrometers, as well as by a scintillation radon counter. The radon measuring instruments were calibrated by known 222 Rn quantities given off from standard RaCl 2 solutions. The overall uncertainty of the data obtained is estimated as being 25%. The minimum measurable effective 226 Ra concentration due to a 10 4 g building material source is calculated as 16 fCi/g for the ionization chambers and 8 fCi/g for the scintillation counter. 68 building material samples and 11 backfill (concrete made by fly-ashes) samples have been studied and it has been found, that the effective 226 Ra contents of the tested building materials are 2 to 9 times greater than those found in the Soviet Union though none exceeds the recommended 600 fCi/g level. Among the back filling materials made with fly-ash the maximum 226 Ra content was 3300 fCi/g. The effective 226 Ra content measurements are well suited for a priori radon escape qualification of building materials. (K.A.)

  6. Device for absorbing seismic effects on buildings

    International Nuclear Information System (INIS)

    Xercavins, Pierre; Pompei, Michel.

    1979-01-01

    Device for absorbing seismic effects. The construction or structure to be protected rests on its foundations through at least one footing formed of a stack of metal plates interlinked by layers of adhesive material, over at least a part of their extent, this material being an elastomer that can distort, characterized in that at least part of the area of some metal plates works in association with components which are able to absorb at least some of the energy resulting from friction during the relative movements of the metal plates against the distortion of the elastomer [fr

  7. Clean nuclear power (2. part)

    International Nuclear Information System (INIS)

    Rocherolles, R.

    1998-01-01

    The 450 nuclear power plants which produce 24% of world electricity do not generate greenhouse gas effects, but 8,000 tonnes per year of irradiated, radioactive fuel. The first article which was published in the July-August 1997 issue of this journal, described the composition and management of these fuels. This article wish to show the advantage of 'advanced re-processing', which would separate fission products from actinides, in order to incinerate them separately in dedicated fuels and reactors, which, from an ecological point of view, seems more efficient than burying them underground in deep, geological layers. To rid the planet of waste which is continuing to build up, the first step is to build 'incinerators' which will eliminate fission products by slow neutron assisted neutronic capture, and actinides by fast neutron assisted fission. Various projects have been set up, in particular, in Los Alamos, Japan and the CERN. The Carlo Rubbia hybrid machine operating on the well-known thorium cycle is the most advanced project. An incinerator connected up to standard PWR reactor produces no actinide, and reduces the existing stock of plutonium. However, the proper solution, obviously, is to no longer produce waste along with power; second generation nuclear fission will do this. The CERN team bas studied a clean reactor, producing practically no actinides, or fission products, more or less. Thus, the solution to the problem of waste is at hand, and nuclear power will be cleaner that all other types of power. The world market opening up to clean nuclear power is about 1,300 Gigawatts, or 1,300 plants of 1,000 Megawatts. Remarkable progress is taking place under our very eyes; soon we will have clean power in sufficient quantities, at a lower cost than that of other forms of power. (authors)

  8. Heat exchanger cleaning

    International Nuclear Information System (INIS)

    Gatewood, J.R.

    1980-01-01

    A survey covers the various types of heat-exchange equipment that is cleaned routinely in fossil-fired generating plants, the hydrocarbon-processing industry, pulp and paper mills, and other industries; the various types, sources, and adverse effects of deposits in heat-exchange equipment; some details of the actual procedures for high-pressure water jetting and chemical cleaning of some specific pieces of equipment, including nuclear steam generators. (DN)

  9. Effects of discharge cleaning on the production of runaway electrons in TORTUS tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Cross, R C; Liu, J R; Giannone, L. (Sydney Univ. (Australia). School of Physics)

    1983-06-01

    Experimental results are presented on the production of runaway electrons as a function of wall cleanliness in the TORTUS tokamak. When the walls are clean, the production rate decreases as the filling pressure increases. When the walls are contaminated by oxygen, the production rate can increase when the filling pressure is increased, owing to the production of water vapour during tokamak discharges. These results resolve the differences reported in the literature on the production of runaways as a function of filling pressure. It is also observed that the runaway electron instability seen in other devices is suppressed when the walls are discharge-cleaned.

  10. Effects of discharge cleaning on the production of runaway electrons in TORTUS tokamak

    International Nuclear Information System (INIS)

    Cross, R.C.; Liu, J.R.; Giannone, L.

    1983-01-01

    Experimental results are presented on the production of runaway electrons as a function of wall cleanliness in the TORTUS tokamak. When the walls are clean, the production rate decreases as the filling pressure increases. When the walls are contaminated by oxygen, the production rate can increase when the filling pressure is increased, owing to the production of water vapour during tokamak discharges. These results resolve the differences reported in the literature on the production of runaways as a function of filling pressure. It is also observed that the runaway electron instability seen in other devices is suppressed when the walls are discharge-cleaned. (author)

  11. The effect of building façade on natural lighting (Case study: Building of phinisi tower UNM)

    Science.gov (United States)

    Jamala, Nurul

    2017-04-01

    Utilization of natural lighting is one factor to lower the energy consumption of a building. Model building facade effect on natural light sources that can be absorbed into the building. UNM Phinisi Tower Building is a metaphor for the display of boats phinisi using Hiperbolic paraboloid facade which is futuristic sophistication of the application of science and technology, so that this object that is the focus of research on the effects on the building facade natural lighting. A quantitative research methods using Autodesk Echotech program to determine the value of the building into the natural lighting illuminance, either by using the facade and do not. The aim of research is to determine the percentage utilization of natural light into the building using a building facade. The study concluded the decline percentage in the value of the illuminance after the building using the building facade is 49% -74% and a mean value of 60.3%, so it can be concluded that the building facade effects on the natural lighting.

  12. Issues and approaches for ensuring effective communication on acceptable daily exposure (ADE) values applied to pharmaceutical cleaning.

    Science.gov (United States)

    Olson, Michael J; Faria, Ellen C; Hayes, Eileen P; Jolly, Robert A; Barle, Ester Lovsin; Molnar, Lance R; Naumann, Bruce D; Pecquet, Alison M; Shipp, Bryan K; Sussman, Robert G; Weideman, Patricia A

    2016-08-01

    This manuscript centers on communication with key stakeholders of the concepts and program goals involved in the application of health-based pharmaceutical cleaning limits. Implementation of health-based cleaning limits, as distinct from other standards such as 1/1000th of the lowest clinical dose, is a concept recently introduced into regulatory domains. While there is a great deal of technical detail in the written framework underpinning the use of Acceptable Daily Exposures (ADEs) in cleaning (for example ISPE, 2010; Sargent et al., 2013), little is available to explain how to practically create a program which meets regulatory needs while also fulfilling good manufacturing practice (GMP) and other expectations. The lack of a harmonized approach for program implementation and communication across stakeholders can ultimately foster inappropriate application of these concepts. Thus, this period in time (2014-2017) could be considered transitional with respect to influencing best practice related to establishing health-based cleaning limits. Suggestions offered in this manuscript are intended to encourage full and accurate communication regarding both scientific and administrative elements of health-based ADE values used in pharmaceutical cleaning practice. This is a large and complex effort that requires: 1) clearly explaining key terms and definitions, 2) identification of stakeholders, 3) assessment of stakeholders' subject matter knowledge, 4) formulation of key messages fit to stakeholder needs, 5) identification of effective and timely means for communication, and 6) allocation of time, energy, and motivation for initiating and carrying through with communications. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. The influence of in situ argon cleaning of GaAs on Schottky diodes and metal-semiconductor field-effect transistors

    NARCIS (Netherlands)

    Hassel, van J.G.; Heyker, H.C.; Kwaspen, J.J.M.

    1995-01-01

    The influence of in situ argon cleaning of GaAs on the electrical characteristics of Schottky diodes and metal–semiconductor field-effect transistors (MESFETs) is investigated. The beam energy was varied from 50 to 500 eV and the characteristics were compared to wet chemically cleaned devices. The

  14. Evaluation of the persistence of functional and biological respiratory health effects in clean-up workers 6 years after the Prestige oil spill.

    NARCIS (Netherlands)

    Zock, J.P.; Rodríguez-Trigo, G.; Rodríguez-Rodríguez, E.; Souto-Alonso, A.; Espinosa, A.; Pozo-Rodríguez, F.; Gómez, F.P.; Fuster, C.; Castaño-Vinyals, G.; Antó, J.M.; Barberà, J.A.

    2014-01-01

    Fishermen who had participated in clean-up activities of the Prestige oil spill showed increased bronchial responsiveness and higher levels of respiratory biomarkers 2years later. We aimed to evaluate the persistence of these functional and biological respiratory health effects 6years after clean-up

  15. Effectiveness of Runoff Control Legislation and Active, Beautiful, Clean (ABC Waters Design Features in Singapore

    Directory of Open Access Journals (Sweden)

    Xue Ping Goh

    2017-08-01

    Full Text Available Storm water management in Singapore has always been a challenge due to intense rainfall in a flat, low-lying and urbanised catchment. PUB’s (Singapore’s National Water Agency recent runoff control regulation limits the runoff coefficient to 0.55 for developments larger than or equal to 0.2 ha. The use of Active, Beautiful, Clean (ABC Waters design features are encouraged to attain peak runoff reduction. Hence the paper focuses on (i determining the actual hydrological response regime of Singapore using the relationship between runoff coefficient (C, land use and slope; and (ii investigating the effectiveness of ABC Waters design features in delaying and reducing peak runoff using a modelling approach. Based on a Storm Water Management Model (SWMM model and using elevation, land use and soil data as inputs, the peak C-values were obtained for 50 m × 50 m grid cells. The results show that for the same land use, the one with steeper slope resulted in a higher runoff coefficient. Simulations were carried out in two study areas, Green Walk District and Tengah Subcatchment, where ABC Waters design features (such as porous pavements, green roofs, rain gardens and detention tanks were incorporated to reduce C-values. Results showed that peak C-values can be reduced to less than 0.55 after increasing the green areas and constructing detention facilities. Reduction in peak discharge (22% to 63% and a delay in peak discharge by up to 30 min were also observed. Hence, it is recommended to consider the relationship between slope and land use while determining runoff coefficients; and to incorporate ABC Waters design features in urban design to reduce the peak flow and runoff coefficient (C.

  16. Cleaning Services.

    Science.gov (United States)

    Sharpton, James L.

    This curriculum guide provides cleaning services instructional materials for a ninth- and tenth-grade Coordinated Vocational Education and Training: Home and Community Services program. It includes 2 sections and 11 instructional units. Each unit of instruction consists of eight basic components: performance objectives, teacher activities,…

  17. 'The Voracity Effect' and Climate Change : The Impact of Clean Technologies

    NARCIS (Netherlands)

    Benchekroun, H.; Ray Chaudhuri, A.

    2010-01-01

    In the absence of a successful international cooperative agreement over the control of emissions there is a growing interest in the role that clean technologies may play to alleviate the climate change problem. Within a non-cooperative transboundary pollution game, we investigate, analytically and

  18. The effect of impurity scattering on the thermally induced charge imbalance in a clean superconductor

    International Nuclear Information System (INIS)

    Nielsen, J.B.; Smith, H.; Ono, Y.A.; Pethick, C.J.

    1980-01-01

    The charge imbalance generated in a current-carrying clean superconductor by a temperature gradient is calculated, assuming that non-magnetic or magnetic impurities are the only source of scattering. The charge imbalance is obtained from exact solutions of the quasiparticle Boltzmann equation, valid at any temperature and superfluid velocity. (author)

  19. Building Effective Medical Missions with Servant Leadership Skills.

    Science.gov (United States)

    Johanson, Linda

    Nurses are naturally drawn to service opportunities, such as short-term medical missions (STMM), which hold great potential to benefit health. But STMMs have been criticized as potentially being culturally insensitive, leading to dependency, inadvertently causing harm, or being unsustainable. Utilizing servant leadership skills, nurses can effectively build community, vision, and sustainability into STMM projects.

  20. Effects of Jaw Clenching and Jaw Alignment Mouthpiece Use on Force Production During Vertical Jump and Isometric Clean Pull.

    Science.gov (United States)

    Allen, Charles R; Fu, Yang-Chieh; Cazas-Moreno, Vanessa; Valliant, Melinda W; Gdovin, Jacob R; Williams, Charles C; Garner, John C

    2018-01-01

    Allen, CR, Fu, Y-C, Cazas-Moreno, V, Valliant, MW, Gdovin, JR, Williams, CC, and Garner, JC. Effects of jaw clenching and jaw alignment mouthpiece use on force production during vertical jump and isometric clean pull. J Strength Cond Res 32(1): 237-243, 2018-This study examined the effects of jaw clenching, a self-adapted, jaw-repositioning mouthpiece on force production during maximum countermovement vertical jump and maximum isometric midthigh clean pull assessments in an attempt to determine any ergogenic effect attributable to clenching, jaw-repositioning mouthpiece use, or the combination of both. Thirty-six male subjects performed vertical jump and isometric clean pull assessments from a force platform under various mouthpiece and clench conditions. A 3 × 2 (mouthpiece × clench) repeated-measures analysis of variance was conducted to analyze each of the following force production variables for both assessments: peak force, normalized peak force, and rate of force development. In addition, jump height was analyzed for the vertical jump. Results revealed improvements in peak force (F1,35 = 15.84, p ≤ 0.001, (Equation is included in full-text article.)= 0.31), normalized peak force (F1,35 = 16.28, p ≤ 0.001, (Equation is included in full-text article.)= 0.32), and rate of force development (F1,35 = 12.89, p = 0.001, (Equation is included in full-text article.)= 0.27) during the isometric clean pull assessment when participants maximally clenched their jaw, regardless of mouthpiece condition. There were no statistically significant differences in jump height, peak force, normalized peak force, or rate of force development during the vertical jump for any treatment condition. This study supports previous research demonstrating that the implementation of remote voluntary contractions such as jaw clenching can lead to concurrent activation potentiation and a resulting ergogenic effect during activities involving and requiring high-force production.

  1. Modeling the Temperature Effect of Orientations in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Sabahat Arif

    2012-07-01

    Full Text Available Indoor thermal comfort in a building has been an important issue for the environmental sustainability. It is an accepted fact that their designs and planning consume a lot of energy in the modern architecture of 20th and 21st centuries. An appropriate orientation of a building can provide thermally comfortable indoor temperatures which otherwise can consume extra energy to condition these spaces through all the seasons. This experimental study investigates the potential effect of this solar passive design strategy on indoor temperatures and a simple model is presented for predicting indoor temperatures based upon the ambient temperatures.

  2. Building effective cybersecurity programs a security manager's handbook

    CERN Document Server

    Schreider, Tari

    2017-01-01

    You know by now that your company could not survive without the Internet. Not in today's market. You are either part of the digital economy or reliant upon it. With critical information assets at risk, your company requires a state-of-the-art cybersecurity program. But how do you achieve the best possible program? Tari Schreider, in Building Effective Cybersecurity Programs: A Security Manager's Handbook, lays out the step-by-step roadmap to follow as you build or enhance your cybersecurity program.

  3. Building effective working relationships across culturally and ethnically diverse communities.

    Science.gov (United States)

    Hosley, Cheryl A; Gensheimer, Linda; Yang, Mai

    2003-01-01

    Amherst H. Wilder Foundation's Social Adjustment Program for Southeast Asians is implementing two collaborative, best practice, mental health and substance abuse prevention service models in Minnesota. It faced several issues in effectively bridging multiple cultural groups, including building a diverse collaborative team, involving families and youth, reconciling cultural variation in meeting styles, and making best practice models culturally appropriate. Researchers and program staff used multiple strategies to address these challenges and build successful partnerships. Through shared goals, flexibility, and a willingness to explore and address challenges, collaboratives can promote stronger relationships across cultural communities and improve their service delivery systems.

  4. Self-cleaning effect in high quality percussion ablating of cooling hole by picosecond ultra-short pulse laser

    Science.gov (United States)

    Zhao, Wanqin; Yu, Zhishui

    2018-06-01

    Comparing with the trepanning technology, cooling hole could be processed based on the percussion drilling with higher processing efficiency. However, it is widely believed that the ablating precision of hole is lower for percussion drilling than for trepanning, wherein, the melting spatter materials around the hole surface and the recast layer inside the hole are the two main issues for reducing the ablating precision of hole, especially for the recast layer, it can't be eliminated completely even through the trepanning technology. In this paper, the self-cleaning effect which is a particular property just for percussion ablating of holes has been presented in detail. In addition, the reasons inducing the self-cleaning effect have been discussed. At last, based on the self-cleaning effect of percussion drilling, high quality cooling hole without the melting spatter materials around the hole surface and recast layer inside the hole could be ablated in nickel-based superalloy by picosecond ultra-short pulse laser.

  5. Effects of energy and carbon taxes on building material competitiveness

    Energy Technology Data Exchange (ETDEWEB)

    Sathre, Roger; Gustavsson, Leif [Ecotechnology, Mid Sweden University, 831 25 Oestersund, (Sweden)

    2007-04-15

    The relations between building material competitiveness and economic instruments for mitigating climate change are explored in this bottom-up study. The effects of carbon and energy taxes on building material manufacturing cost and total building construction cost are modelled, analysing individual materials as well as comparing a wood-framed building to a reinforced concrete-framed building. The energy balances of producing construction materials made of wood, concrete, steel, and gypsum are described and quantified. For wood lumber, more usable energy is available as biomass residues than is consumed in the processing steps. The quantities of biofuels made available during the production of wood materials are calculated, and the cost differences between using these biofuels and using fossil fuels are shown under various tax regimes. The results indicate that higher energy and carbon taxation rates increase the economic competitiveness of wood construction materials. This is due to both the lower energy cost for material manufacture, and the increased economic value of biomass by-products used to replace fossil fuel. (Author)

  6. Measured moisture in buildings and adverse health effects: a review.

    Science.gov (United States)

    Mendell, Mark J; Macher, Janet M; Kumagai, Kazukiyo

    2018-04-23

    It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support the setting of health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of quantified building moisture and occupant health effects identified three eligible studies. Two studies assessed associations between measured wall moisture content and respiratory health in the UK. Both reported dose-related increases in asthma exacerbation with higher measured moisture, with one study reporting an adjusted odds ratio (OR) of 7.0 for night-time asthma symptoms with higher bedroom moisture. The third study assessed relationships between infrared camera-determined wall moisture and atopic dermatitis in South Korea, reporting an adjusted OR of 14.5 for water-damaged homes and moderate or severe atopic dermatitis. Measuring building moisture has, despite extremely limited available findings, potential promise for detecting unhealthy D/M in homes and merits more research attention. Further research to validate these findings should include measured "water activity," which directly assesses moisture availability for microbial growth. Ultimately, evidence-based, health-related thresholds for building moisture, across specific materials and measurement devices, could better guide assessment and remediation of D/M in buildings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Effects of opening in shear walls of 30- storey building

    Directory of Open Access Journals (Sweden)

    Ruchi Sharma

    2015-03-01

    Full Text Available Tall towers and multi-storey buildings have fascinated mankind from the beginning of civilization, their construction being initially for defense and subsequently for ecclesiastical purposes. These tall buildings because of its height, is affected by lateral forces due to wind or earthquake actions tends to snap the building in shear and push it over in bending. In general, the rigidity (i.e. Resistance to lateral deflection and stability (i.e. Resistance to overturning moments requirement become more important. Shear walls (Structural walls contribute significant lateral stiffness, strength, and overall ductility and energy dissipation capacity. In many structural walls a regular pattern of openings has to be provided due to various functional requirements such as to accommodate doors, windows and service ducts. Such type of openings reduces the stiffness of the shear wall to some extent depending on the shape and size of the opening. In the present parametric study, efforts are made to investigate and critically assess the effects of various size of openings in shear walls on the responses and behaviors of multi-storey buildings. The 30 storey Prototype buildings with different types of openings in shear wall with and without incorporating the volume of shear wall reduced in the boundary elements are analyzed using software E-TABS using Response spectrum method (1893(Part-1-2002 and Time history method.

  8. METHODS OF SELECTING THE EFFECTIVE MODELS OF BUILDINGS REPROFILING PROJECTS

    Directory of Open Access Journals (Sweden)

    Александр Иванович МЕНЕЙЛЮК

    2016-02-01

    Full Text Available The article highlights the important task of project management in reprofiling of buildings. It is expedient to pay attention to selecting effective engineering solutions to reduce the duration and cost reduction at the project management in the construction industry. This article presents a methodology for the selection of efficient organizational and technical solutions for the reconstruction of buildings reprofiling. The method is based on a compilation of project variants in the program Microsoft Project and experimental statistical analysis using the program COMPEX. The introduction of this technique in the realigning of buildings allows choosing efficient models of projects, depending on the given constraints. Also, this technique can be used for various construction projects.

  9. [Intestinal cleaning for colonoscopy in children: effectiveness, adherence and adverse effects of schemes differentiated by age].

    Science.gov (United States)

    Miquel, Isabel; Arancibia, María Eugenia; Alliende, Francisco; Ríos, Gloria; Rodríguez, Lorena; Lucero, Yalda; Saelzer, Eric

    2017-04-01

    Adequate intestinal cleanliness is crucial to achieve optimal colonoscopy performance. Several bowel preparation (BP) schemes have been proposed, but there is still no consensus as regards which is the most suitable in paediatric patients. To describe the effectiveness, adherence, and adverse effects of BP protocols differentiated by age group in paediatric patients subjected to colonoscopy. Prospective, study that included patients PEG 3350 without electrolytes); 4y-9y 11 m (PEG 3350 without electrolytes + bisacodyl); 10 y-18 y (PEG 3350 with electrolytes). Demographic, clinical information, adherence and adverse effects were registered. Effectiveness was determined using a validated scale (Boston modified) during colonoscopy. A total of 159 patients were included, of which 87 (55%) were males, and with a median age of 4 years (range 1 m-17 years). Seventy eight percent of patients achieved successful BP. The higher effectiveness was observed in the groups of < 6 m (96%) and 10-18 y (91%). Constipation was significantly more frequent (29%) in the 4 yo-9 yo 11 m in which lower effectiveness was observed (69%). Good adherence was observed in 87% of patients. Adverse effects were observed in a third of patients, although they were mild and did not lead to the suspension of the BP. Satisfactory results were achieved with the BP schemes used, with a successful BP being obtained in 4 out of 5 patients. Results were different between groups, which is probably related to previous bowel transit and indicated medication.

  10. [Effects of rice cleaning and cooking process on the residues of flutolanil, fenobucarb, silafluofen and buprofezin in rice].

    Science.gov (United States)

    Satoh, Motoaki; Sakaguchi, Masayuki; Kobata, Masakazu; Sakaguchi, Yoko; Tanizawa, Haruna; Miura, Yuri; Sasano, Ryoichi; Nakanishi, Yutaka

    2003-02-01

    We studied the effect of cleaning and cooking on the residues of flutolanil, fenobucarb, silafluofen and buprofezin in rice. The rice had been sprayed in a paddy field in Wakayama city, with 3 kinds of pesticide application protocols: spraying once at the usual concentration of pesticides, repeated spraying (3 times) with the usual concentration of pesticides and spraying once with 3 times the usual concentration of pesticides. The residue levels of pesticide decreased during the rice cleaning process. Silafluofen, which has a higher log Pow value, remained in the hull of the rice. Fenobucarb, which has a lower log Pow value, penetrated inside the rice. The residue concentration of pesticide in polished rice was higher than that in pre-washed rice processed ready for cooking. During the cooking procedure, the reduction of pesticides in polished rice was higher than that in brown rice.

  11. WINDOW-CLEANING

    CERN Multimedia

    Environmental Section / ST-TFM

    2001-01-01

    The two-month window-cleaning session on the Meyrin, Prévessin and LEP sites will soon begin. The cleaning contractors will work from Monday to Saturday, every week from 4.00 a.m. to 8.00 p.m. The work will be organised so as to disturb users as little as possible. In any event, a work notice will be left in each office 24 hours beforehand. To prevent any damage to documents or items which could occur despite the precautions taken, please clear completely the window-sills and the area immediately around them. If, however, for valid reasons, the work cannot be done on the scheduled day, please inform the Environmental Section by telephoning: 73753 / 74233 / 72242 If you are going to be absent during this two-month period, we should be grateful if you would clear the above mentioned areas before your departure. REMINDER To allow more thorough cleaning of the entrance doors to buildings and also facilitate the weekly work of the cleaning contractors, we ask you to make use of the notice boards at the...

  12. Bioinspired Surface for Low Drag, Self-Cleaning, and Antifouling: Shark Skin, Butterfly and Rice Leaf Effects

    Science.gov (United States)

    Bixler, Gregroy D.

    In this thesis, first presented is an overview of inorganic-fouling and biofouling which is generally undesirable for many medical, marine, and industrial applications. A survey of nature's flora and fauna are studied in order to discover new antifouling methods that could be mimicked for engineering applications. New antifouling methods will presumably incorporate a combination of physical and chemical controls. Presented are mechanisms and experimental results focusing on laminar and turbulent drag reducing shark skin inspired riblet surfaces. This includes new laser etched and riblet film samples for closed channel drag using water, oil, and air as well as in wind tunnel. Also presented are mechanisms and experimental results focusing on the newly discovered rice and butterfly wing effect surfaces. Morphology, drag, self-cleaning, contact angle, and contact angle hysteresis data are presented to understand the role of sample geometrical dimensions, wettability, viscosity, and velocity. Hierarchical liquid repellent coatings combining nano- and micro-sized features and particles are utilized to recreate or combine various effects. Such surfaces have been fabricated with photolithography, soft lithography, hot embossing, and coating techniques. Discussion is provided along with new conceptual models describing the role of surface structures related to low drag, self-cleaning, and antifouling properties. Modeling provides design guidance when developing novel low drag and self-cleaning surfaces for medical, marine, and industrial applications.

  13. Radon entry into buildings: Effects of atmospheric pressure fluctuations and building structural factors

    International Nuclear Information System (INIS)

    Robinson, A.L.

    1996-05-01

    An improved understanding of the factors that control radon entry into buildings is needed in order to reduce the public health risks caused by exposure to indoor radon. This dissertation examines three issues associated with radon entry into buildings: (1) the influence of a subslab gravel layer and the size of the openings between the soil and the building interior on radon entry; (2) the effect of atmospheric pressure fluctuations on radon entry; and (3) the development and validation of mathematical models which simulate radon and soil-gas entry into houses. Experiments were conducted using two experimental basements to examine the influence of a subslab gravel layer on advective radon entry driven by steady indoor-outdoor pressure differences. These basement structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The measurements indicate that a high permeability subslab gravel layer increases the advective radon entry rate into the structure by as much as a factor of 30. The magnitude of the enhancement caused by the subslab gravel layer depends on the area of the openings in the structure floor; the smaller the area of these openings the larger the enhancement in the radon entry rate caused by the subslab gravel layer. A three-dimensional, finite-difference model correctly predicts the effect of a subslab gravel layer and open area configuration on advective radon entry driven by steady indoor-outdoor pressure differences; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5

  14. Radon entry into buildings: Effects of atmospheric pressure fluctuations and building structural factors

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Allen Lantham [Univ. of California, Berkeley, CA (United States). Dept. of Mechanical Engineering

    1996-05-01

    An improved understanding of the factors that control radon entry into buildings is needed in order to reduce the public health risks caused by exposure to indoor radon. This dissertation examines three issues associated with radon entry into buildings: (1) the influence of a subslab gravel layer and the size of the openings between the soil and the building interior on radon entry; (2) the effect of atmospheric pressure fluctuations on radon entry; and (3) the development and validation of mathematical models which simulate radon and soil-gas entry into houses. Experiments were conducted using two experimental basements to examine the influence of a subslab gravel layer on advective radon entry driven by steady indoor-outdoor pressure differences. These basement structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The measurements indicate that a high permeability subslab gravel layer increases the advective radon entry rate into the structure by as much as a factor of 30. The magnitude of the enhancement caused by the subslab gravel layer depends on the area of the openings in the structure floor; the smaller the area of these openings the larger the enhancement in the radon entry rate caused by the subslab gravel layer. A three-dimensional, finite-difference model correctly predicts the effect of a subslab gravel layer and open area configuration on advective radon entry driven by steady indoor-outdoor pressure differences; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5.

  15. Clean cars

    Energy Technology Data Exchange (ETDEWEB)

    Piffaretti, M.

    2008-07-01

    This well-illustrated presentation made at the Swiss 2008 research conference on traffic by the Protoscar company takes a look at research, design, engineering and communication topics in the area of 'clean cars'. The present situation with electrically driven and hybrid-drive cars is reviewed and the chances and problems of the present-day vehicles are examined. New developments and a number of vehicles that should be on the market in the period from 2012 to 2015 are presented. Also, 'clean' specialist vehicles such as trucks and buses are reviewed. Battery systems and associated problems and new developments are looked at. The promotion scheme in Mendrisio, Switzerland is reviewed. Bottom-up and top-down approaches are discussed and future market developments are looked at, as are promotional activities in various countries.

  16. The clean development mechanism versus international permit trading: The effect on technological change

    International Nuclear Information System (INIS)

    Hagem, Cathrine

    2009-01-01

    The clean development mechanism of the Kyoto Protocol may induce technological change in developing countries. As an alternative to the clean development mechanism regime, developing countries may accept a (generous) cap on their own emissions, allow domestic producers to invest in new efficient technologies, and sell the excess emission permits on the international permit market. The purpose of this article is to show how the gains from investment, and hence the incentive to invest in new technology in developing countries, differ between the two alternative regimes. We show that the difference in the gains from investment depends on whether the producers in developing countries face competitive or noncompetitive output markets, whether the investment affects fixed or variable production costs, and whether producers can reduce emissions through means other than investing in new technology. (author)

  17. The Effects of Psychosocial Factors on Work Accidents in Izmir Konak Municipality Cleaning Workers.

    OpenAIRE

    Aysun Akgun; Ahmet Soysal; Yucel Demiral

    2010-01-01

    AIM: The aim of this cross-sectional study was to investigate the relationship between psychosocial factors and work accidents among waste collector workers in Izmir Konak Municipality Cleaning Services Section. The study consisted 92 (%68) out of 135 workers of those accepted to participation. METHOD: face-to-face questionnaire were administered for data collection. Dependent variable was the work-related accident for previous six months. Independent variables were sociodemographic features,...

  18. Energy Building Regulations: The Effect of the Federal Performance Standards on Building Code Administration and the Conservation of Energy in New Buildings.

    Science.gov (United States)

    Kopper, William D.

    1980-01-01

    Explores the changes in the administration and enforcement of building regulations that will be engendered by the proposed federal energy building standards. Also evaluates the effectiveness of those standards in meeting congressional intent. Available from U.C. Davis Law Review, School of Law, Martin Luther King Jr. Hall, University of…

  19. An analysis of cost effective incentives for initial commercial deployment of advanced clean coal technologies

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, D.F. [SIMTECHE, Half Moon Bay, CA (United States)

    1997-12-31

    This analysis evaluates the incentives necessary to introduce commercial scale Advanced Clean Coal Technologies, specifically Integrated Coal Gasification Combined Cycle (ICGCC) and Pressurized Fluidized Bed Combustion (PFBC) powerplants. The incentives required to support the initial introduction of these systems are based on competitive busbar electricity costs with natural gas fired combined cycle powerplants, in baseload service. A federal government price guarantee program for up to 10 Advanced Clean Coal Technology powerplants, 5 each ICGCC and PFBC systems is recommended in order to establish the commercial viability of these systems by 2010. By utilizing a decreasing incentives approach as the technologies mature (plants 1--5 of each type), and considering the additional federal government benefits of these plants versus natural gas fired combined cycle powerplants, federal government net financial exposure is minimized. Annual net incentive outlays of approximately 150 million annually over a 20 year period could be necessary. Based on increased demand for Advanced Clean Coal Technologies beyond 2010, the federal government would be revenue neutral within 10 years of the incentives program completion.

  20. Numerical Study of High-Speed Droplet Impact on Surfaces and its Physical Cleaning Effects

    Science.gov (United States)

    Kondo, Tomoki; Ando, Keita

    2015-11-01

    Spurred by the demand for cleaning techniques of low environmental impact, one favors physical cleaning that does not rely on any chemicals. One of the promising candidates is based on water jets that often involve fission into droplet fragments and collide with target surfaces to which contaminant particles (often micron-sized or even smaller) stick. Hydrodynamic force (e.g., shearing and lifting) arising from the droplet impact will play a role to remove the particles, but its detailed mechanism is still unknown. To explore the role of high-speed droplet impact in physical cleaning, we solve compressible Navier-Stokes equations with a finite volume method that is designed to capture both shocks and material interfaces in accurate and robust manners. Water hammer and shear flow accompanied by high-speed droplet impact at a rigid wall is simulated to evaluate lifting force and rotating torque, which are relevant to the application of particle removal. For the simulation, we use the numerical code recently developed by Computational Flow Group lead by Tim Colonius at Caltech. The first author thanks Jomela Meng for her help in handling the code during his stay at Caltech.

  1. Geothermal energy - effective solutions for heating and cooling of buildings

    International Nuclear Information System (INIS)

    Veleska, Viktorija

    2014-01-01

    Energy and natural resources are essential prerequisites for the maintenance of the life and the development of human civilization. With the advancement of technology is more emphasis on energy efficiency and reducing carbon dioxide emissions. Energy efficiency is using less power without reducing the quality of life. Almost half of the energy used is devoted to buildings, including heating and cooling. Buildings are a major source of CO_2 emissions in the atmosphere. Reducing the impact of buildings on the environment and the development of renewable energy, energy solutions are key factor in terms of sustainable development. Energy and geothermal pumps posts represent effective solutions for large facilities for heating and cooling. Geothermal energy piles represent a system of pipes that circulate thermal fluid and embedded in earth, thus extracting heat from the bearing to satisfy the needs for heating and cooling. Experience has shown that this type of energy piles can save up to two thirds of the cost of conventional heating, while geothermal pump has the ability to low temperature resources (such as groundwater and earth) to extract energy and raise the higher level needed for heating buildings. Their implementation is supported by an active group of researchers working with industry to demonstrate the benefits of dual benefit performance at the foundations. Initiative for renewable heat and potential for further adoption of solutions with these technologies is rapidly expanding. The use of this source of energy has great potential due to environmental, economic and social benefits. (author)

  2. The National Shipbuilding Research Program. Cost-Effective Clean Up of Spent Grit

    National Research Council Canada - National Science Library

    2000-01-01

    The National Shipbuilding Research Program and, in particular, the SP-1 and SP-3 panels have long recognized the economic and environmental significance of surface preparation and coating in the building of ship...

  3. Building lifespan: effect on the environmental impact of building components in a Danish perspective

    DEFF Research Database (Denmark)

    Marsh, Rob

    2017-01-01

    of building lifespan are inadequately addressed. The aim of this research is therefore to explore how environmental impact from building components is affected by building lifespans of 50, 80, 100 and 120 years in a Danish context. LCAs are undertaken for 792 parametric variations of typical construction...... solutions, covering all primary building components and based on contemporary practice. A full statistical analysis is carried out, which shows a significant statistical correlation between changes in building lifespan and environmental impact for all primary building components, except windows......Construction professionals must now integrate environmental concerns with life cycle assessment (LCA) early in the procurement process. Building lifespan is important to LCA, since results must be normalized on an annualized basis for comparison. However, the scientific literature shows that issues...

  4. Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end.

  5. Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Jing [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China)], E-mail: zhaojing@tju.edu.cn; Wu Yong [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China); Zhu Neng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China)

    2009-06-15

    The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end.

  6. Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jing; Zhu, Neng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China); Wu, Yong [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China)

    2009-06-15

    The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end. (author)

  7. IDEA Clean Energy Application Center

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Robert P. [International District Energy Association, Westborough, MA (United States)

    2013-12-20

    /feasibility tool for these types of community energy projects. The Excel based tool incorporates hourly climate based building loads data to arrive at the composite energy demand for the district and compares the Net Present Value (NPV) of the costs of CHP/DE alternatives. This tool has been used to provide assistance to several projects in the Northeast, Mid-Atlantic, Intermountain and Pacific Regions. The tool was disseminated to the CEACs and supplemented by a Training Webinar and a How to Guide IDEA produced a US Community Energy Development Guide to support mayors, planners, community leaders, real estate developers and economic development officials who are interested in planning more sustainable urban energy infrastructure, creating community energy master plans and implementing CHP/ District Energy systems in cities, communities and towns. IDEA has collected industry data and provided a comprehensive data set containing information on District Energy installations in the US. District energy systems are present in 49 states and theDistrict of Columbia. Of the 597 systems 55% were DE alone while the remainder was some combination of CHP, district heating, and district cooling. District energy systems that do not currently involve electric generation are strong near-term candidates for the adoption of CHP due to the magnitude of their aggregated thermal load. This data has helped inform specific and targeted initiatives including technical assistance provided by the CEAC’s for EPA’s Boiler MACT Compliance by large District Heating System boilers. These outcomes have been greatly enabled by the close coordination and collaboration with DOE CEAC leadership and with the eight regional US DOE Clean Energy Application Centers and the award’s incremental funding has allowed IDEA to leverage our resources to be an effective champion for Clean Energy.

  8. Environmental effect of structural solutions and building materials to a building

    International Nuclear Information System (INIS)

    Haapio, Appu; Viitaniemi, Pertti

    2008-01-01

    The field of building environmental assessment tools has become a popular research area over the past decade. However, how the service life of a building affects the results of the environmental assessment of a building has not been emphasised previously. The aim of this study is to analyse how different structural solutions and building materials affect the results of the environmental assessment of a whole building over the building's life cycle. Furthermore, how the length of the building's service life affects the results is analysed. The environmental assessments of 78 single-family houses were calculated for this study. The buildings have different wall insulations, claddings, window frames, and roof materials, and the length of the service life varies from 60 years up to 160 years. The current situation and the future of the environmental assessment of buildings are discussed. In addition, topics for further research are suggested; for example, how workmanship affects the service life and the environmental impact of a building should be studied

  9. Effect of UV on building materials in New Zealand

    International Nuclear Information System (INIS)

    Bennett, A.F.

    1993-01-01

    Building materials can be divided into two main classes; organic or polymeric based and inorganic materials. Inorganic materials are in most cases largely unaffected by UV radiation. Many common polymers have bonds sensitive to radiation in the UV region. Absorption of radiation of these wavelengths will lead to excitation of electrons which can lead to isomerisation, chain scissors, cross linking and free radical formation. It is worth noting that the effects of UV radiation are always acting synergistically with other environmental effects. (author). 4 refs., 2 tabs

  10. The repetition effect in building and construction works

    DEFF Research Database (Denmark)

    Gottlieb, Stefan Christoffer; Haugbølle, Kim

    are then applied on the Public Transport Authorities' main account structure of units and costs, and a method for assessing the possibilities of achieving effects of repetition for each account is described. Finally, the report summarises the core conditions necessary to take into consideration in relation......This report summarises the results from the work undertaken for the Public Transport Authority on the effect of learning and repetition in building and construction works. The results are applied by the Public Transport Authority in a new budgeting model, while the agency investigates...

  11. The Effectiveness of HCl and HF Cleaning of Si0.85Ge0.15 Surface

    International Nuclear Information System (INIS)

    Sun, Y

    2008-01-01

    The cleaning of Si 0.85 Ge 0.15 surfaces using HCl and HF solutions is studied using synchrotron radiation photoelectron spectroscopy. The HF solution is found to be effective in removing both the Si oxide and the Ge oxide while the HCl solution can only remove part of the Ge oxide. For samples treated with HF, four spectral components are needed to fit the Ge 3d photoemission spectra. One is the bulk component and the other three are attributed to the surface Ge atoms with mono-hydride, di-hydride and tri-hydride terminations, respectively

  12. Effects of physical and chemical aspects on membrane fouling and cleaning using interfacial free energy analysis in forward osmosis.

    Science.gov (United States)

    Zhang, Wanzhu; Dong, Bingzhi

    2018-05-20

    Natural organic matter (NOM) in micro-polluted water purification using membranes is a critical issue to handle. Understanding the fouling mechanism in the forward osmosis (FO) process, particularly identifying the predominant factor that controls membrane fouling, could have significant effects on exerting the advantages of FO technique. Cellulose triacetate no-woven (CTA-NW) membrane is applied to experiments with a high removal efficiency (> 99%) for the model foulant. Tannic acid (TA) is used as a surrogate foulant for NOM in the membrane fouling process, thus enabling the analysis of the effects of physical and chemical aspects of water flux, retention, and adsorption. The membrane fouling behavior is affected mainly by the combined effects of the osmotic dragging force and the interaction of the pH in the working solution, foulants, and calcium ions, as demonstrated by the water flux loss and the changes of membrane retention and adsorption. The fouled CTA-NW membrane (in PRO mode) could be flux-recovered by > 85% through physical cleaning methods. The interfacial free energy analysis theory was used to analyze the membrane fouling behavior with calculating the interfacial cohesion and adhesion free energies. The cohesion free energy refers to the deposition of foulants (TA or TA combined with calcium ions) on a fouled membrane. In addition, the adhesion free energy could be used to evaluate the interaction between foulants and a clean membrane.

  13. Effective removal of airborne 222Rn decay products inside buildings

    International Nuclear Information System (INIS)

    Maher, E.F.; Rudnick, S.N.; Moeller, D.W.

    1987-01-01

    Comparisons were made of the effectiveness of various indoor air treatment methods in reducing the lung dose due to inhalation of 222 Rn decay products. The comparisons were based upon measurements of the total steady-state concentrations of 218 Po, 214 Pb and 214 Bi, and the concentrations of these nuclides not attached to particles. These measurements, which were made inside a 78-m3 room before and after air treatment, were used along with a state-of-the art lung dose model to predict reductions in the dose to the radiosensitive bronchial tissues. Results suggest that flow-through air-cleaning methods, such as filtration and electrostatic precipitation, although effective in reducing total potential alpha energy concentration, cause a greater quantity of airborne potential alpha energy to be unattached to particles. This may result in a substantial increase in the dose to bronchial tissues. The optimal form of air treatment appears to be a combination of nonuniform positive space charge generated by an ion generator and enhanced convection from a fan. This combination of air treatment gave reductions in the mean dose to the bronchial tissues of up to 87%

  14. Researching effective approaches to cleaning in hospitals: protocol of the REACH study, a multi-site stepped-wedge randomised trial.

    Science.gov (United States)

    Hall, Lisa; Farrington, Alison; Mitchell, Brett G; Barnett, Adrian G; Halton, Kate; Allen, Michelle; Page, Katie; Gardner, Anne; Havers, Sally; Bailey, Emily; Dancer, Stephanie J; Riley, Thomas V; Gericke, Christian A; Paterson, David L; Graves, Nicholas

    2016-03-24

    The Researching Effective Approaches to Cleaning in Hospitals (REACH) study will generate evidence about the effectiveness and cost-effectiveness of a novel cleaning initiative that aims to improve the environmental cleanliness of hospitals. The initiative is an environmental cleaning bundle, with five interdependent, evidence-based components (training, technique, product, audit and communication) implemented with environmental services staff to enhance hospital cleaning practices. The REACH study will use a stepped-wedge randomised controlled design to test the study intervention, an environmental cleaning bundle, in 11 Australian hospitals. All trial hospitals will receive the intervention and act as their own control, with analysis undertaken of the change within each hospital based on data collected in the control and intervention periods. Each site will be randomised to one of the 11 intervention timings with staggered commencement dates in 2016 and an intervention period between 20 and 50 weeks. All sites complete the trial at the same time in 2017. The inclusion criteria allow for a purposive sample of both public and private hospitals that have higher-risk patient populations for healthcare-associated infections (HAIs). The primary outcome (objective one) is the monthly number of Staphylococcus aureus bacteraemias (SABs), Clostridium difficile infections (CDIs) and vancomycin resistant enterococci (VRE) infections, per 10,000 bed days. Secondary outcomes for objective one include the thoroughness of hospital cleaning assessed using fluorescent marker technology, the bio-burden of frequent touch surfaces post cleaning and changes in staff knowledge and attitudes about environmental cleaning. A cost-effectiveness analysis will determine the second key outcome (objective two): the incremental cost-effectiveness ratio from implementation of the cleaning bundle. The study uses the integrated Promoting Action on Research Implementation in Health Services (i

  15. THE EFFECT OF BUILDING FAÇADE MODEL ON LIGHT DISTRIBUTION (CASE STUDY: MENARA PHINISI BUILDING OF UNM

    Directory of Open Access Journals (Sweden)

    Nurul Jamala

    2017-12-01

    Full Text Available Global warming issues influence the temperature of the earth surface. It is an impact on energy consumption, especially in buildings. Utilization of daylight is one of the factors that need to be considered, in order to minimize energy consumption as a source of artificial lighting. This study analyzed the distribution of light on the Menara Phinisi building of Makassar State University. Quantitative research method that is to describe the data of simulation in Autodesk Ecotect program. The research objective was to determine the effect of the building facade model on the value of illumination inside the building. Results of the study concluded that the decrease percentage of the distribution of light on the building facade using and not using the facade is 3,16% or 236 lux. Distribution of light in horizontal and diagonal facade models differ in the amount of 2,5%. Design analysis of the building serves as a guide for analyzing the influence of the building facade model so that it can create energy efficient buildings.

  16. The effects of multimedia advertising on building brand equity

    Directory of Open Access Journals (Sweden)

    Reza Pirayesh

    2014-08-01

    Full Text Available This paper presents an empirical investigation to study the effects of multimedia advertisement on building brand equity. The proposed study uses two questionnaires, one for multimedia advertisement, which consists of 17 questions and the other one for measuring brand equity. The survey is applied among 384 randomly selected customers who do their daily businesses with banks located in province of Kordestan, Iran. Using Pearson correlation as well as linear regression techniques, the study has determined a positive and meaningful relationship between these two variables. In our survey, word of mouth advertisement seems to have the highest impact on brand equity followed by having seminars.

  17. The filtering effect of buildings on airborne particulate matter

    International Nuclear Information System (INIS)

    Christensen, G.C.; Mustonen, R.

    1987-06-01

    Within the radioecological programme of the Nordic Liaison Committee for Atomic Energy (NKA), the possible consequences of a major reactor accident are one of its main research branches. This study of the filtering effect of buildings on airborne particulate matter has been one part of this branch. The absorbed dose to a person from a passing radioactive cloud will be lower if he has been indoors and not ourdoors during the cloud passage. The aim of this study has been to find filtering factors for typical Finnish and Norwegian houses to use in model work

  18. Key Performance Indicator of Building Maintenance and Its Effect on the Building Life Cycle

    Directory of Open Access Journals (Sweden)

    M.A. Othuman Mydin

    2014-07-01

    Full Text Available Building maintenance is considered as one of the national agenda. Multitude barriers received by the services providers have undergone various difficulties in satisfying public interest have been progressively resolved as a sign towards becoming a more developed country. In real practice, building maintenance is the thing which we mostly tolerate. If the building is able to weather the elements, we may with delay taking action on it. Most buildings are always treated with ‘ad-hoc’ maintenance. In some instances, the building disrepair will wait until complaints are made before any repair work is done. It shows that the situation is not considered critical as it may. Maintenance is still being practiced in improper procedure by the maintenance managers which subsequently caused bad impacts to the facilities and the services provided. It can be seen that the managers prefer carrying out reactive maintenance works rather than proactive works and at times do not consider the clients satisfaction and also the performance of services. This paper will focus on some important elements of building maintenance and its relation to building performance holistically.

  19. Clean Water Action Plan: Restoring and protecting America`s waters

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    On October 18, 1997, the 25th anniversary of the enactment of the Clean Water Act, the Vice President called for a renewed effort to restore and protect water quality. The Vice President asked that the Secretary of Agriculture and the Administrator of the Environmental Protection Agency (EPA), working with other affected agencies, develop a Clean Water Action Plan that builds on clean water successes and addresses three major goals: (1) enhanced protection from public health threats posed by water pollution; (2) more effective control of polluted runoff; and (3) promotion of water quality protection on a watershed basis.

  20. The concentrations of phthalates in settled dust in Bulgarian homes in relation to building characteristic and cleaning habits in the family

    DEFF Research Database (Denmark)

    Kolarik, Barbara; Bornehag, Carl-Gustaf; Naydenov, Kiril Georgiev

    2008-01-01

    . Dust samples from the child's bedroom were collected in 177 homes and analysed for the content of dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), butyl benzyl phthalate (BBzP), di-n-octyl phthalate (DnOP) and DEHP. Information on building characteristics and family...... spectra, and wood flooring. However, in a sub-group of homes with no use of polish, the concentration of DEHP was higher in homes with inspector-observed balatum compared with wood flooring but the difference was not significant may be due to a too small sample size....

  1. Building shielding effects on radiation doses from routine radionuclide releases

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1977-01-01

    In calculating population doses from the release of radionuclides to the atmosphere, it is usually assumed that man spends all of his time outdoors standing on a smooth infinite plane. Realistically, however, man spends most of the time indoors, so that substantial reductions in radiation doses may result compared with the usual estimates. Calculational models were developed to study the effects of building structures on radiation doses from routine releases of radionuclides to the atmosphere. Both internal dose from inhaled radionuclides and external photon dose from airborne and surface-deposited radionuclides are considered. The effect of building structures is described quantitatively by a dose reduction factor, which is the ratio of the dose inside a structure to the corresponding dose with no structure present. The internal dose from inhaled radionuclides is proportional to the radionuclide concentration in the air. Assuming that the outdoor airborne concentration is constant with time, the time-dependence of the indoor airborne concentration in terms of the structure air ventilation rate, the deposition velocities for radionuclides on the inside floor, walls, and ceiling, and the radioactive decay constant, were calculated

  2. Upright nanopyramid structured cover glass with light harvesting and self-cleaning effects for solar cell applications

    International Nuclear Information System (INIS)

    Amalathas, Amalraj Peter; Alkaisi, Maan M

    2016-01-01

    In this paper, we demonstrate the effect of upright nanopyramid (UNP) structured cover glass with light harvesting and self-cleaning functions on the device performance of monocrystalline Si solar cells. The UNP structures were fabricated on the surface of the glass substrate by simple, high throughput and low cost UV nanoimprint lithography, using a Si master mold with inverted nanopyramid (INP) structures. The diffuse transmittance and haze ratio values were significantly increased for UNP patterned glass, especially in the wavelength range 300–600 nm compared to the bare glass; this implies that antireflection and strong light scattering are due to the UNP structures. By replacing a bare cover glass with UNP patterned glass, the power conversion efficiency of the monocrystalline Si solar cell was substantially enhanced by about 10.97%; this is mainly due to the increased short-circuit current density J SC of 32.39 mA cm −2 compared to the reference cell with bare cover glass (i.e. J SC   =  31.60 mA cm −2 ). In addition, unlike the bare cover glass (i.e. θ CA ∼ 36°), the fluorinated UNP structured cover glass exhibited a hydrophobic surface with a water contact angle ( θ CA ) of ∼132° and excellent self-cleaning of dust particles by rolling down water droplets. (paper)

  3. Effects of Multiple Cleaning and Disinfection Interventions on Infectious Diseases in Children: A Group Randomized Trial in China.

    Science.gov (United States)

    Ban, Hai Qun; Li, Tao; Shen, Jin; Li, Jin; Peng, Pin Zhang; Ye, Heng Ping; Zhang, Liu Bo

    2015-11-01

    To assess the effectiveness of multiple cleaning and disinfection interventions in the homes and kindergartens, in reducing gastrointestinal and respiratory illnesses of children. From October 2010 to September 2011, we performed a prospective, controlled study in China. 408 children under 5 years old were recruited and group randomized into intervention and control groups. Families and kindergartens in the intervention group were provided with antibacterial products for hand hygiene and surface cleaning or disinfection for one year. Each child's illness symptoms and sick leave were recorded every day. A total of 393 children completed the study, with similar baseline demographics in each of the 2 groups. Except for abdominal pain, the odds of symptoms (fever, cough and expectoration, runny nose and nasal congestion, diarrhea), illness (acute respiratory illness and gastrointestinal illness), and sick leave per person each month were significantly reduced by interventions. The rates of fever, diarrhea, acute respiratory illness, gastrointestinal illness and sick leave per person per year were significantly decreased as well. Not only the acute respiratory and gastrointestinal illness but the sick leave rate in children were significantly reduced by multiple interventions. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  4. Plasma cleaning of beamline optical components: Contamination and gas composition effects

    International Nuclear Information System (INIS)

    Rosenberg, R.A.; Smith, J.A.; Wallace, D.J.

    1992-01-01

    We have initiated a program to study the impact of gas composition on the carbon removal rate during plasma cleaning of optical components, and of possible contamination due to the plasma processing. The measurements were performed in a test chamber designed to simulate the geometry of the grating/Codling mirror section of a Grasshopper monochromator. Removal rates were determined for a direct-current (dc) (Al electrode) discharge using a quartz crystal microbalance coated with polymethylmethacrylate, located at the position of the grating. Auger electron spectroscopy analysis of strateg- ically located, gold-coated stainless steel samples was employed to determine contamination. The relative removal rates of the gases studied were 3% C 2 F 6 /O 2 much-gt O 2 +H 2 O>O 2 ∼N 2 O>H 2 >N 2 . Although the C 2 F 6 /O 2 gas mixture showed a 20 times greater removal rate than its nearest competitor, it also caused significant contamination to occur. Contamination studies were performed for both dc and radio-frequency (rf) discharges. For the dc discharge we found that great care must be taken in order to avoid Al contamination; for the rf discharge, significant Fe contamination was observed

  5. The effects of Title IV of the Clean Air Act amendments of 1990 on electric utilities: An update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This report presents data and analyses related to Phase I implementation of the Clean Air Act Amendment by electric utilities. It describes the strategies used to comply with the Acid Rain Program in 1995, the effect of compliance on sulfur dioxide emissions levels, the cost of compliance, and the effects of the program on coal supply and demand. The first year of Phase I demonstrated that the market-based sulfur dioxide emissions control system could achieve significant reductions in emissions at lower than expected costs. Some utilities reduced aggregate emissions below legal requirements due to economic incentives; other utilities purchased additional allowances to avoid noncompliance. More than half of the utilities switched to or blended with lower sulfur coal, due to price reductions in the coal market which were partially due to the allowance trading program. 21 figs., 20 tabs.

  6. Rancho Seco building wake effects on atmospheric diffusion

    International Nuclear Information System (INIS)

    Start, G.E.; Cate, J.H.; Dickson, C.R.; Ricks, N.R.; Ackerman, G.R.; Sagendorf, J.F.

    1977-11-01

    A series of 23 paired gaseous tracer releases at the Rancho Seco Nuclear Power Station in 1975 was the third of several tests designed to investigate the diffusion characteristics of the atmosphere under conditions of low windspeed and temperature inversion. This test also evaluated the effects of flow around buildings upon dilution of pollutants. Gaseous tracers were laterally dispersed about six times more than the expected amounts from Pasquill--Gifford curves of sigma-y. Most of this increase could be related to observed variance of the horizontal wind direction (meandering). For ground-level releases the effective sigma-z values were 16 times greater than the corresponding values from the Pasquill--Gifford curves. Measured ground-level axial concentrations were about 75 times smaller than predicted by the Gaussian diffusion equation for a ground-level release when Pasquill--Gifford values of sigma-y and sigma-z were used

  7. Health effects associated with energy conservation measures in commercial buildings

    International Nuclear Information System (INIS)

    Stenner, R.D.; Baechler, M.C.

    1990-09-01

    Indoor air quality can be impacted by hundreds of different chemicals. More than 900 different organic compounds alone have been identified in indoor air. Health effects that could arise from exposure to individual pollutants or mixtures of pollutants cover the full range of acute and chronic effects, including largely reversible responses, such as rashes and irritations, to the irreversible toxic and carcinogenic effects. These indoor contaminants are emitted from a large variety of materials and substances that are widespread components of everyday life. Pacific Northwest Laboratory conducted a search of the peer-reviewed literature on health effects associated with indoor air contaminants for the Bonneville Power Administration to aid the agency in the preparation of environmental documents. Results are reported in two volumes. Volume 1 summarizes the results of the search of the peer-reviewed literature on health effects associated with a selected list of indoor air contaminants. In addition, the report discusses potential health effects of polychlorinated biphenyls and chlorofluorocarbons. All references to the literature reviewed are found in this document Volume 2. Volume 2 provides detailed information from the literature reviewed, summarizes potential health effects, reports health hazard ratings, and discusses quantitative estimates of carcinogenic risk in humans and animals. Contaminants discussed in this report are those that; have been measured in the indoor air of a public building; have been measured (significant concentrations) in test situations simulating indoor air quality (as presented in the referenced literature); and have a significant hazard rating. 38 refs., 7 figs., 23 tabs

  8. Health effects associated with energy conservation measures in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, R.D.; Baechler, M.C.

    1990-09-01

    Indoor air quality can be impacted by hundreds of different chemicals. More than 900 different organic compounds alone have been identified in indoor air. Health effects that could arise from exposure to individual pollutants or mixtures of pollutants cover the full range of acute and chronic effects, including largely reversible responses, such as rashes and irritations, to the irreversible toxic and carcinogenic effects. These indoor contaminants are emitted from a large variety of materials and substances that are widespread components of everyday life. Pacific Northwest Laboratory conducted a search of the peer-reviewed literature on health effects associated with indoor air contaminants for the Bonneville Power Administration to aid the agency in the preparation of environmental documents. Results are reported in two volumes. Volume 1 summarizes the results of the search of the peer-reviewed literature on health effects associated with a selected list of indoor air contaminants. In addition, the report discusses potential health effects of polychlorinated biphenyls and chlorofluorocarbons. All references to the literature reviewed are found in this document Volume 2. Volume 2 provides detailed information from the literature reviewed, summarizes potential health effects, reports health hazard ratings, and discusses quantitative estimates of carcinogenic risk in humans and animals. Contaminants discussed in this report are those that; have been measured in the indoor air of a public building; have been measured (significant concentrations) in test situations simulating indoor air quality (as presented in the referenced literature); and have a significant hazard rating. 38 refs., 7 figs., 23 tabs.

  9. Revegetation Plan for Areas of the Fitzner-Eberhardt Arid Lands Ecology Reserve Affected by Decommissioning of Buildings and Infrastructure and Debris Clean-up Actions

    Energy Technology Data Exchange (ETDEWEB)

    Downs, Janelle L.; Durham, Robin E.; Larson, Kyle B.

    2011-01-01

    The U.S. Department of Energy (DOE), Richland Operations Office is working to remove a number of facilities on the Fitzner Eberhardt Arid Lands Ecology Reserve (ALE), which is part of the Hanford Reach National Monument. Decommissioning and removal of buildings and debris on ALE will leave bare soils and excavated areas that need to be revegetated to prevent erosion and weed invasion. Four main areas within ALE are affected by these activities (DOE 2009;DOE/EA-1660F): 1) facilities along the ridgeline of Rattlesnake Mountain, 2) the former Nike missile base and ALE HQ laboratory buildings, 3) the aquatic research laboratory at Rattlesnake Springs area, and 4) a number of small sites across ALE where various types of debris remain from previous uses. This revegetation plan addresses the revegetation and restoration of those land areas disturbed by decommissioning and removal of buildings, facilities and associated infrastructure or debris removal. The primary objective of the revegetation efforts on ALE is to establish native vegetation at each of the sites that will enhance and accelerate the recovery of the native plant community that naturally persists at that location. Revegetation is intended to meet the direction specified by the Environmental Assessment (DOE 2009; DOE/EA-1660F) and by Stipulation C.7 of the Memorandum of Agreement (MOA) for the Rattlesnake Mountain Combined Community Communication Facility and InfrastructureCleanup on the Fitzner/Eberhardt Arid Lands Ecology Reserve, Hanford Site, Richland Washington(DOE 2009; Appendix B). Pacific Northwest National Laboratory (PNNL) under contract with CH2M Hill Plateau Remediation Company (CPRC) and in consultation with the tribes and DOE-RL developed a site-specific strategy for each of the revegetation units identified within this document. The strategy and implementation approach for each revegetation unit identifies an appropriate native species mix and outlines the necessary site preparation activities

  10. Effects of welding fumes on nuclear air cleaning system carbon adsorber banks

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, P.W. [Duke Power Company, Huntersville, NC (United States)

    1997-08-01

    Standard Technical Specifications for nuclear air cleaning systems include requirements for surveillance tests following fire, painting, or chemical release in areas communicating with the affected system. To conservatively implement this requirement, many plants categorize welding as a chemical release process, and institute controls to ensure that welding fumes do not interact with carbon adsorbers in a filter system. After reviewing research data that indicated welding had a minimal impact on adsorber iodine removal efficiency, further testing was performed with the goal of establishing a welding threshold. It was anticipated that some quantity of weld electrodes could be determined that had a corresponding detrimental impact on iodine removal efficiency for the exposed adsorber. This value could be used to determine a conservative sampling schedule that would allow the station to perform laboratory testing to ensure system degradation did not occur without a full battery of surveillance tests. A series of tests was designed to demonstrate carbon efficiency versus cumulative welding fume exposure. Three series of tests were performed, one for each of three different types of commonly used weld electrodes. Carbon sampling was performed at baseline conditions, and every five pounds of electrode thereafter. Two different laboratory tests were performed for each sample; one in accordance with ASTM 3803/1989 at 95% relative humidity and 30 degrees C, and another using the less rigorous conditions of 70% relative humidity and 80 degrees C. Review of the test data for all three types of electrodes failed to show a significant correlation between carbon efficiency degradation and welding fume exposure. Accordingly, welding is no longer categorized as a `chemical release process` at McGuire Nuclear Station, and limits on welding fume interaction with ventilation systems have been eliminated. 4 refs., 3 figs., 1 tab.

  11. Clean Cities Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    2004-01-01

    This fact sheet explains the Clean Cities Program and provides contact information for all coalitions and regional offices. It answers key questions such as: What is the Clean Cities Program? What are alternative fuels? How does the Clean Cities Program work? What sort of assistance does Clean Cities offer? What has Clean Cities accomplished? What is Clean Cities International? and Where can I find more information?

  12. National Clean Fleets Partnership (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2012-01-01

    Provides an overview of Clean Cities National Clean Fleets Partnership (NCFP). The NCFP is open to large private-sector companies that have fleet operations in multiple states. Companies that join the partnership receive customized assistance to reduce petroleum use through increased efficiency and use of alternative fuels. This initiative provides fleets with specialized resources, expertise, and support to successfully incorporate alternative fuels and fuel-saving measures into their operations. The National Clean Fleets Partnership builds on the established success of DOE's Clean Cities program, which reduces petroleum consumption at the community level through a nationwide network of coalitions that work with local stakeholders. Developed with input from fleet managers, industry representatives, and Clean Cities coordinators, the National Clean Fleets Partnership goes one step further by working with large private-sector fleets.

  13. Characteristics and self-cleaning effect of the transparent super-hydrophobic film having nanofibers array structures

    Science.gov (United States)

    Lee, Kyungjun; Lyu, Sungnam; Lee, Sangmin; Kim, Youn Sang; Hwang, Woonbong

    2010-09-01

    Transparent super-hydrophobic films were fabricated using the PDMS method and silane process, based on anodization in phosphoric acid. Contact angle tests were performed to determine the contact angle of each film according to the anodizing time. Transmittance tests also were performed to obtain the transparency of each TPT (trimethylolpropane propoxylate triacrylate) replica film according to the anodizing time. The contact angle was determined by studying the drop shape, and the transmittance was measured using a UV-spectrometer. The contact angle increases with increasing anodizing time, because increasing pillar length can trap more air between the TPT replica film and a drop of water. The transmittance falls with increasing anodizing time because the increasing pillar length causes a scattering effect. This study shows that the pillar length and transparency are inversely proportional. The TPT replica film having nanofibers array structures was better than other films in aspect of self-cleaning by doing quantitative experimentation.

  14. Apical Transportation, Centering Ability, and Cleaning Effectiveness of Reciprocating Single-file System Associated with Different Glide Path Techniques.

    Science.gov (United States)

    de Carvalho, Guilherme Moreira; Sponchiado Junior, Emílio Carlos; Garrido, Angela Delfina Bittencourt; Lia, Raphael Carlos Comelli; Garcia, Lucas da Fonseca Roberti; Marques, André Augusto Franco

    2015-12-01

    The aim of this study was to evaluate the apical transportation, the centering ability, and the cleaning effectiveness of a reciprocating single-file system associated to different glide path techniques. The mesial root canals of 52 mandibular molars were randomly distributed into 4 groups (n = 13) according to the different glide path techniques used before biomechanical preparation with Reciproc System (RS): KF/RS (sizes 10 and 15 K-files), NGP/RS (no glide path, only reciprocating system), PF/RS (sizes 13, 16, and 19 PathFile instruments), and NP (no preparation). Cone-beam computed tomography analysis was performed before and after instrumentation for apical third images acquisition. Apical transportation and its direction were evaluated by using the formula D = (X1 - X2) - (Y1 - Y2), and the centering ability was analyzed by the formula CC = (X1 - X2/Y1 - Y2 or Y1 - Y2/X1 - X2). The samples were submitted to histologic processing and analyzed under a digital microscope for debris quantification. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test, P .05). Groups had a tendency toward transportation in the mesial direction. No technique had perfect centering ability (=1.0), with no significant difference among them. KF/RS had larger amount of debris, with statistically significant difference in comparison with NGP/RS (P > .05). The different glide path techniques promoted minimal apical transportation, and the reciprocating single-file system tested remained relatively centralized within the root canal. Also, the different techniques interfered in the cleaning effectiveness of the reciprocating system. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Effects of opening in shear walls of 30- storey building

    OpenAIRE

    Ruchi Sharma; Jignesh A Amin

    2015-01-01

    Tall towers and multi-storey buildings have fascinated mankind from the beginning of civilization, their construction being initially for defense and subsequently for ecclesiastical purposes. These tall buildings because of its height, is affected by lateral forces due to wind or earthquake actions tends to snap the building in shear and push it over in bending. In general, the rigidity (i.e. Resistance to lateral deflection) and stability (i.e. Resistance to overturning moments) requirement ...

  16. Rice- and butterfly-wing effect inspired self-cleaning and low drag micro/nanopatterned surfaces in water, oil, and air flow

    Science.gov (United States)

    Bixler, Gregory D.; Bhushan, Bharat

    2013-12-01

    In search of new solutions to complex challenges, researchers are turning to living nature for inspiration. For example, special surface characteristics of rice leaves and butterfly wings combine the shark skin (anisotropic flow leading to low drag) and lotus leaf (superhydrophobic and self-cleaning) effects, producing the so-called rice and butterfly wing effect. In this paper, we study four microstructured surfaces inspired by rice leaves and fabricated with photolithography techniques. We also present a method of creating such surfaces using a hot embossing procedure for scaled-up manufacturing. Fluid drag, self-cleaning, contact angle, and contact angle hysteresis data are presented to understand the role of sample geometrical dimensions. Conceptual modeling provides design guidance when developing novel low drag, self-cleaning, and potentially antifouling surfaces for medical, marine, and industrial applications.

  17. Building construction materials effect in tropical wet and cold climates: A case study of office buildings in Cameroon

    Directory of Open Access Journals (Sweden)

    Modeste Kameni Nematchoua

    2016-03-01

    Full Text Available This paper presents the results of an experimental study that was conducted in 15 office buildings in the humid and cold tropics during the working hours of the dry and rainy seasons in Cameroon. This was with the aim to study the effects that local and imported materials had on indoor air quality. To achieve this objective, the adaptive model approach has been selected. In accordance with the conditions of this model, all workers were kept in natural ventilation and, in accordance with the general procedure, a questionnaire was distributed to them, while variables, like air temperature, wind speed, and relative humidity were sampled. The results showed a clear agreement between expected behaviour, in accordance with the characteristics of building construction, and its real indoor ambience once they were statistically analysed. On the other hand, old buildings showed a higher percentage of relative humidity and a lower degree of indoor air temperature. Despite this, local thermal comfort indices and questionnaires showed adequate indoor ambience in each group of buildings, except when marble was used for external tiling. The effect of marble as an external coating helps to improve indoor ambience during the dry season. This is due to more indoor air and relative humidity being accumulated. At the same time, these ambiences are degraded when relative humidity is higher. Finally, these results should be taken cognisance of by architects and building designers in order to improve indoor environment, and overcome thermal discomfort in the Saharan area.

  18. Biofouling of reverse osmosis membranes: effects of cleaning on biofilm microbial communities, membrane performance, and adherence of extracellular polymeric substances.

    Science.gov (United States)

    Al Ashhab, Ashraf; Sweity, Amer; Bayramoglu, Bihter; Herzberg, Moshe; Gillor, Osnat

    2017-05-01

    Laboratory-scale reverse osmosis (RO) flat-sheet systems were used with two parallel flow cells, one treated with cleaning agents and a control (ie undisturbed). The cleaning efforts increased the affinity of extracellular polymeric substances (EPS) to the RO membrane and altered the biofilm surface structure. Analysis of the membrane biofilm community composition revealed the dominance of Proteobacteria. However, within the phylum Proteobacteria, γ-Proteobacteria dominated the cleaned membrane biofilm, while β-Proteobacteria dominated the control biofilm. The composition of the fungal phyla was also altered by cleaning, with enhancement of Ascomycota and suppression of Basidiomycota. The results suggest that repeated cleaning cycles select for microbial groups that strongly attach to the RO membrane surface by producing rigid and adhesive EPS that hampers membrane performance.

  19. Effect of cleaning and disinfection of toys on infectious diseases and micro-organisms in daycare nurseries.

    Science.gov (United States)

    Ibfelt, T; Engelund, E H; Schultz, A C; Andersen, L P

    2015-02-01

    The rising number of children in daycare nurseries increases opportunities for the transmission of infectious diseases. Pathogens may be transmitted directly from child to child via sneezing, coughing and touching, or indirectly via the environment. Toys are among the fomites with the highest pathogen load, but their role in disease transmission is unknown. To determine if washing and disinfection of toys can reduce sickness absence and microbial pathogen load in the nursery environment. Twelve nurseries (caring for 587 children) were randomized to intervention and control groups. The intervention consisted of washing and disinfection of toys and linen every two weeks for three months by a commercial cleaning company. The extent and causes of sickness absence among the children were recorded in both groups before and after introduction of the intervention. Ten sampling points in each nursery were examined for bacteria and respiratory viruses. The presence of respiratory virus DNA/RNA was widespread, but very few pathogenic bacteria were found in the environment. The intervention reduced the presence of adenovirus [odds ratio (OR) 2.4, 95% confidence interval (CI) 1.1-5.0], rhinovirus (OR 5.3, 95% CI 2.3-12.4) and respiratory syncytial virus (OR 4.1, 95% CI 1.5-11.2) compared with the control group, but the intervention had no effect on sickness absence or disease patterns in the nurseries. Although cleaning and disinfection of toys every two weeks can decrease the microbial load in nurseries, it does not appear to reduce sickness absence among nursery children. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  20. Shear-lag effect and its effect on the design of high-rise buildings

    Directory of Open Access Journals (Sweden)

    Dat Bui Thanh

    2018-01-01

    Full Text Available For super high-rise buildings, the analysis and selection of suitable structural solutions are very important. The structure has not only to carry the gravity loads (self-weight, live load, etc., but also to resist lateral loads (wind and earthquake loads. As the buildings become taller, the demand on different structural systems dramatically increases. The article considers the division of the structural systems of tall buildings into two main categories - interior structures for which the major part of the lateral load resisting system is located within the interior of the building, and exterior structures for which the major part of the lateral load resisting system is located at the building perimeter. The basic types of each of the main structural categories are described. In particular, the framed tube structures, which belong to the second main category of exterior structures, seem to be very efficient. That type of structure system allows tall buildings resist the lateral loads. However, those tube systems are affected by shear lag effect - a nonlinear distribution of stresses across the sides of the section, which is commonly found in box girders under lateral loads. Based on a numerical example, some general conclusions for the influence of the shear-lag effect on frequencies, periods, distribution and variation of the magnitude of the internal forces in the structure are presented.

  1. Shear-lag effect and its effect on the design of high-rise buildings

    Science.gov (United States)

    Thanh Dat, Bui; Traykov, Alexander; Traykova, Marina

    2018-03-01

    For super high-rise buildings, the analysis and selection of suitable structural solutions are very important. The structure has not only to carry the gravity loads (self-weight, live load, etc.), but also to resist lateral loads (wind and earthquake loads). As the buildings become taller, the demand on different structural systems dramatically increases. The article considers the division of the structural systems of tall buildings into two main categories - interior structures for which the major part of the lateral load resisting system is located within the interior of the building, and exterior structures for which the major part of the lateral load resisting system is located at the building perimeter. The basic types of each of the main structural categories are described. In particular, the framed tube structures, which belong to the second main category of exterior structures, seem to be very efficient. That type of structure system allows tall buildings resist the lateral loads. However, those tube systems are affected by shear lag effect - a nonlinear distribution of stresses across the sides of the section, which is commonly found in box girders under lateral loads. Based on a numerical example, some general conclusions for the influence of the shear-lag effect on frequencies, periods, distribution and variation of the magnitude of the internal forces in the structure are presented.

  2. DESIGNING AND EFFICIENCY EFFECT OF AUTOMATIC BALL-CLEANING SYSTEM FOR CONDENSER 180-KTsS-1 OF TURBINE Т-180/210-130-1 LMZ. Part 1

    Directory of Open Access Journals (Sweden)

    Yu. A. Zenovich-Leshkevich-Ol’pinskiy

    2015-01-01

    Full Text Available In order to reduce losses in the cooling source (condenser and to increase effectiveness of fuel-and-power resources utilization, the authors present a modern automatic ball-cleaning system for the pipes of condenser 180-KTsS-1 of turbine unit Т-180/210-130-1 LMZ of Gomel CHP-2. The article examines exploitation challenges of the steam turbine condensers and methods of clearing them from sedimentations. Depending on the sedimentation character and composition, and the quality of cooling water at the power plant, they apply various methods of the condenser tubes clearing: heat drying, vacuum dehydration, acid-washing, pipes-shooting with water and water-air pistols, ablution with high-pressure water jet etc. All the applied cleaning methods are the periodical means to fight the sedimentations and require the turbine halting or unloading, predetermine the equipment operating between clearings with constantly smearing cooling surfaces of the condensers, i.e. with reduced efficiency of equipment operation.The installation of the ball-cleaning system practically excludes defects of the chemical and mechanical cleaning methods, which leads to the condenser pipes life-in-service increase, the full-flow condensate quality improvement, reliability and efficient performance enhancement of the steam turbines equipment. The authors consider developed algorithms of data processing and designed system control of the condenser cleaning that allowed realizing its operation in automatic mode.

  3. Wind load effects on high rise buildings in Peninsular Malaysia

    Science.gov (United States)

    Nizamani, Z.; Thang, K. C.; Haider, B.; Shariff, M.

    2018-04-01

    Wind is a randomly varying dynamic phenomenon composed of a multitude of eddies of varying sizes and rotational characteristics along a general stream of air moving relative to the ground. These eddies give wind its gustiness, creating fluctuation and results in a complex flow characteristics. The wind vector at any point can be regarded as the sum of mean wind vector and the fluctuation components. These components not only vary with height but also dependant on the approach terrain and topography. Prevailing wind exerts pressure onto the structural surfaces. The effects of wind pressure in the form of shear and bending moments are found to be a major problem in structural failure. This study aims to study the effects of wind load on a fifteen-storey high rise building using EN 1991-1-4 code and MS1553:2002. The simulation results showed that by increasing the wind speed, the storey resultant forces, namely storey shear and storey moment increases significantly. Furthermore, simulation results according to EN 1991-1-4 yield higher values compared to the simulation results according to MS1553:2002.

  4. Effect of loading on peak power of the bar, body, and system during power cleans, squats, and jump squats.

    Science.gov (United States)

    McBride, Jeffrey M; Haines, Tracie L; Kirby, Tyler J

    2011-08-01

    Nine males (age 24.7 ± 2.1 years, height 175.3 ± 5.5 cm, body mass 80.8 ± 7.2 kg, power clean 1-RM 97.1 ± 6.36 kg, squat 1-RM = 138.3 ± 20.9 kg) participated in this study. On day 1, the participants performed a one-repetition maximum (1-RM) in the power clean and the squat. On days 2, 3, and 4, participants performed the power clean, squat or jump squat. Loading for the power clean ranged from 30% to 90% of the participant's power clean 1-RM and loading for the squat and jump squat ranged from 0% to 90% of the participant's squat 1-RM, all at 10% increments. Peak force, velocity, and power were calculated for the bar, body, and system (bar + body) for all power clean, squat, and jump squat trials. Results indicate that peak power for the bar, body, and system is differentially affected by load and movement pattern. When using the power clean, squat or jump squat for training, the optimal load in each exercise may vary. Throwing athletes or weightlifters may be most concerned with bar power, but jumpers or sprinters may be more concerned with body or system power. Thus, the exercise type and load vary according to the desired stimulus.

  5. Pilot-scale continuous ultrasonic cleaning equipment reduces Listeria monocytogenes levels on conveyor belts.

    Science.gov (United States)

    Tolvanen, Riina; Lundén, Janne; Hörman, Ari; Korkeala, Hannu

    2009-02-01

    Ultrasonic cleaning of a conveyor belt was studied by building a pilot-scale conveyor with an ultrasonic cleaning bath. A piece of the stainless steel conveyor belt was contaminated with meat-based soil and Listeria monocytogenes strains (V1, V3, and B9) and incubated for 72 h to allow bacteria to attach to the conveyor belt surfaces. The effect of ultrasound with a potassium hydroxide-based cleaning detergent was determined by using the cleaning bath at 45 and 50 degrees C for 30 s with and without ultrasound. The detachment of L. monocytogenes from the conveyor belt caused by the ultrasonic treatment was significantly greater at 45 degrees C (independent samples t test, P conveyor belt is effective even with short treatment times.

  6. Effects of 20–100 nm particles on liquid clouds in the clean summertime Arctic

    Directory of Open Access Journals (Sweden)

    W. R. Leaitch

    2016-09-01

    Full Text Available Observations addressing effects of aerosol particles on summertime Arctic clouds are limited. An airborne study, carried out during July 2014 from Resolute Bay, Nunavut, Canada, as part of the Canadian NETCARE project, provides a comprehensive in situ look into some effects of aerosol particles on liquid clouds in the clean environment of the Arctic summer. Median cloud droplet number concentrations (CDNC from 62 cloud samples are 10 cm−3 for low-altitude cloud (clouds topped below 200 m and 101 cm−3 for higher-altitude cloud (clouds based above 200 m. The lower activation size of aerosol particles is  ≤  50 nm diameter in about 40 % of the cases. Particles as small as 20 nm activated in the higher-altitude clouds consistent with higher supersaturations (S for those clouds inferred from comparison of the CDNC with cloud condensation nucleus (CCN measurements. Over 60 % of the low-altitude cloud samples fall into the CCN-limited regime of Mauritsen et al. (2011, within which increases in CDNC may increase liquid water and warm the surface. These first observations of that CCN-limited regime indicate a positive association of the liquid water content (LWC and CDNC, but no association of either the CDNC or LWC with aerosol variations. Above the Mauritsen limit, where aerosol indirect cooling may result, changes in particles with diameters from 20 to 100 nm exert a relatively strong influence on the CDNC. Within this exceedingly clean environment, as defined by low carbon monoxide and low concentrations of larger particles, the background CDNC are estimated to range between 16 and 160 cm−3, where higher values are due to activation of particles  ≤  50 nm that likely derive from natural sources. These observations offer the first wide-ranging reference for the aerosol cloud albedo effect in the summertime Arctic.

  7. Effective Dissemination - Building an 'Evidence to Impact' Strategy

    Directory of Open Access Journals (Sweden)

    Dan O'Neill

    2017-02-01

    within VetCompass will be discussed to highlight the most effective vehicles for individual audiences. Traditional dissemination vehicles include peer-reviewed publications and conference talks but the authors will explore the utility of online interactive tools, poster infographics, social media, YouTube, newspaper, TV and radio in addition to engagement via embedding key groups within primary research itself. Effective dissemination pathways must be realistic within the resources available, and ideally should also enhance future evidence generation.For maximally effective EBVM, it is no longer enough to assume that if we build it, they will come. Instead, we must take our evidence to the audience.

  8. Clean energy utilization technology

    International Nuclear Information System (INIS)

    Honma, Takuya

    1992-01-01

    The technical development of clean energy including the utilization of solar energy was begun in 1973 at the time of the oil crisis, and about 20 years elapsed. Also in Japan, the electric power buying system by electric power companies for solar light electric power and wind electric power has been started in 1992, namely their value as a merchandise was recognized. As for these two technologies, the works of making the international standards and JIS were begun. The range of clean energy or natural energy is wide, and its kinds are many. The utilization of solar heat and the electric power generation utilizing waves, tide and geotherm already reached the stage of practical use. Generally in order to practically use new energy, the problem of price must be solved, but the price is largely dependent on the degree of spread. Also the reliability, durability and safety must be ensured, and the easiness of use, effectiveness and trouble-saving maintenance and operation are required. For the purpose, it is important to packaging those skillfully in a system. The cases of intelligent natural energy systems are shown. Solar light and wind electric power generation systems and the technology of transporting clean energy are described. (K.I.)

  9. Sodium Sulphate Effect on Cement Produced with Building Stone Waste

    Directory of Open Access Journals (Sweden)

    Emre Sancak

    2015-01-01

    Full Text Available In this study, the blended cements produced by using the building stone waste were exposed to sulphate solution and the cement properties were examined. Prepared mortar specimens were cured under water for 28 days and then they were exposed to three different proportions of sodium sulphate solution for 125 days. Performances of cements were determined by means of compressive strength and tensile strength tests. The broken parts of some mortar bars were examined with scanning electron microscope (SEM. Besides, they were left under moist atmosphere and their length change was measured and continuously monitored for period of 125 days. In blended cements, solely cements obtained by replacing 10–20% of diatomites gave similar strength values with ordinary Portland cement (CEM I 42.5R at the ages of 7, 28, and 56 days. In all mortar specimens that included either waste andesite (AP or marble powder (MP showed best performance against very severe effective sodium sulphate solutions (13500 mg/L.

  10. Effect of urban climate on building integrated photovoltaics performance

    International Nuclear Information System (INIS)

    Tian Wei; Wang Yiping; Ren Jianbo; Zhu Li

    2007-01-01

    It is generally recognized that BIPV (building integrated photovoltaics) has the potential to become a major source of renewable energy in the urban environment. The actual output of a PV module in the field is a function of orientation, total irradiance, spectral irradiance, wind speed, air temperature, soiling and various system-related losses. In urban areas, the attenuation of solar radiation due to air pollution is obvious, and the solar spectral content subsequently changes. The urban air temperature is higher than that in the surrounding countryside, and the wind speed in urban areas is usually less than that in rural areas. Three different models of PV power are used to investigate the effect of urban climate on PV performance. The results show that the dimming of solar radiation in the urban environment is the main reason for the decrease of PV module output using the climatic data of urban and rural sites in Mexico City for year 2003. The urban PV conversion efficiency is higher than that of the rural PV system because the PV module temperature in the urban areas is slightly lower than that in the rural areas in the case. The DC power output of PV seems to be underestimated if the spectral response of PV in the urban environment is not taken into account based on the urban hourly meteorological data of Sao Paulo for year 2004

  11. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    NARCIS (Netherlands)

    Kenters, N.; Huijskens, E.G.; Wit, S.C.J. de; Sanders, I.; Rosmalen, J. van; Kuijper, E.J.; Voss, A.

    2017-01-01

    BACKGROUND: In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested for their

  12. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    NARCIS (Netherlands)

    Kenters, N.; E. Huijskens (Elisabeth); de Wit, S.C.J.; Sanders, I.G.J.M.; J.M. van Rosmalen (Joost); E. Kuijper; Voss, A.

    2017-01-01

    textabstractBackground: In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested

  13. Clean water, Sanitation and Diarrhoea in Indonesia: Effects of Household and Community Factors

    NARCIS (Netherlands)

    Komarulzaman, A.; Smits, J.P.J.M.; Jong, E. de

    2017-01-01

    Diarrhoea is an important health issue in low- and middle-income countries, including Indonesia. We applied a multilevel regression analysis on the Indonesian Demographic and Health Survey to examine the effects of drinking water and sanitation facilities at the household and community level on

  14. Clean water, sanitation and diarrhoea in Indonesia: Effects of household and community factors.

    Science.gov (United States)

    Komarulzaman, Ahmad; Smits, Jeroen; de Jong, Eelke

    2017-09-01

    Diarrhoea is an important health issue in low- and middle-income countries, including Indonesia. We applied a multilevel regression analysis on the Indonesian Demographic and Health Survey to examine the effects of drinking water and sanitation facilities at the household and community level on diarrhoea prevalence among children under five (n = 33,339). The role of the circumstances was explored by studying interactions between the water and sanitation variables and other risk factors. Diarrhoea prevalence was reported by 4820 (14.4%) children, who on average were younger, poorer and were living in a poorer environment. At the household level, piped water was significantly associated with diarrhoea prevalence (OR = 0.797, 95% CI: 0.692-0.918), improved sanitation had no direct effect (OR = 0.992, 95% CI: 0.899-1.096) and water treatment was not related to diarrhoea incidence (OR = 1.106, 95% CI: 0.994-1.232). At the community level, improved water coverage had no direct effect (OR = 1.002, 95% CI: 0.950-1.057) but improved sanitation coverage was associated with lower diarrhoea prevalence (OR = 0.917, 95% CI: 0.843-0.998). Our interaction analysis showed that the protective effects of better sanitation at the community level were increased by better drinking water at the community level. This illustrates the importance of improving both drinking water and sanitation simultaneously.

  15. Some factors influencing the effective use of disinfectants and cleaning agents

    Directory of Open Access Journals (Sweden)

    W.P. Kortenbout

    1982-09-01

    Full Text Available Disinfection means the freeing of an article from some or all of its burden of live pathogenic microorganisms which might cause infection during its use. The term is a relative one and disinfection may be described as being partially or highly effective according to the proportion of pathogenic organisms killed or removed.

  16. A 10-day vacancy period after cleaning and disinfection has no effect on the bacterial load in pig nursery units.

    Science.gov (United States)

    Luyckx, K; Millet, S; Van Weyenberg, S; Herman, L; Heyndrickx, M; Dewulf, J; De Reu, K

    2016-10-19

    Biosecurity measures such as cleaning, disinfection and a vacancy period between production cycles on pig farms are essential to prevent disease outbreaks. No studies have tested the effect of a longer vacancy period on bacterial load in nursery units. The present study evaluated the effect of a 10-day vacancy period in pig nursery units on total aerobic flora, Enterococcus spp., Escherichia coli, faecal coliforms and methicillin resistant Staphylococcus aureus (MRSA). Three vacancy periods of 10 days were monitored, each time applied in 3 units. The microbiological load was measured before disinfection and at 1, 4, 7 and 10 days after disinfection. No significant decrease or increase in E. coli, faecal coliforms, MRSA and Enterococcus spp. was noticed. Total aerobic flora counts were the lowest on day 4 after disinfection (i.e. 4.07 log CFU/625 cm 2 ) (P disinfection, drinking nipples were still mostly contaminated with total aerobic flora (i.e. 5.32 log CFU/625 cm 2 ) and Enterococcus spp. (i.e. 95 % of the samples were positive) (P disinfection with no extra biosecurity measures has no impact on the environmental load of total aerobic flora, E. coli, faecal coliforms, MRSA and Enterococcus spp..

  17. Chemical cleaning of UK AGR boilers

    International Nuclear Information System (INIS)

    Rudge, A.; Turner, P.; Ghosh, A.; Clary, W.; Tice, D.

    2002-01-01

    For the first time in their operational lives, UK advanced gas-cooled reactor once-through boilers have been chemically cleaned. Chemical cleaning was necessary to avoid lost output resulting from boiler pressure drops, which had been increasing for a number of years. Chemical cleaning of these boilers presents a number of unique difficulties. These include lack of access to the boilers, highly sensitised 316H superheater sections that cannot be excluded from the cleaning flow path, relatively thin boiler tube walls and an intolerance to boiler tube failure because of the role of the boilers in nuclear decay heat removal. The difficulties were overcome by implementing the clean in a staged manner, starting with an extensive materials testwork programme to select and then to substantiate the cleaning process. The selected process was based on ammoniated citric acid plus formic acid for the principal acid cleaning stage. Materials testwork was followed by an in-plant trial clean of six boiler tubes, further materials testwork and the clean of a boiler tube in a full-scale test rig. An overview is presented of the work that was carried out to demonstrate that the clean could be carried out safely, effectively and without leading to unacceptable corrosion losses. Full-scale chemical cleaning was implemented by using as much of the existing plant as possible. Careful control and monitoring was employed to ensure that the cleaning was implemented according to the specified design, thus ensuring that a safe and effective clean was carried out. Full-scale cleaning has resulted in significant boiler pressure drop recovery, even though the iron burden was relatively low and cleaning was completed in a short time. (orig.)

  18. Effect of structural design on traffic-induced building vibrations

    DEFF Research Database (Denmark)

    Persson, Peter; Andersen, Lars Vabbersgaard; Persson, Kent

    2017-01-01

    Population growth and urbanization results in densified cities, where new buildings are being built closer to existing vibration sources such as road-, tram- and rail traffic. In addition, new transportation systems are constructed closer to existing buildings. Potential disturbing vibrations...... are one issue to consider in planning urban environment and densification of cities. Vibrations can be disturbing for humans but also for sensitive equipment in, for example, hospitals. In determining the risk for disturbing vibrations, the distance between the source and the receiver, the ground...... properties, and type and size of the building are governing factors. In the paper, a study is presented aiming at investigating the influence of various parameters of the building's structural design on vibration levels in the structure caused by ground surface loads, e.g. traffic. Parameters studied...

  19. Emulsion type dry cleaning system

    International Nuclear Information System (INIS)

    Kohanawa, Osamu; Matsumoto, Hiroyo.

    1988-01-01

    Protective clothing against radioactive contamination used in the radiation controlled areas of nuclear plants has been washed by the same wet washing as used for underwear washing, but recently dry cleaning is getting used in place of wet washing, which generates a large quantity of laundry drain. However, it was required to use wet washing once every five to ten dry cleanings for washing protective clothing, because conventional dry cleaning is less effective in removing water-soluble soils. Therefore, in order to eliminate wet washing, and to decrease the quantity of laundry drains, the emulsion type dry cleaning system capable of removing both oil-soluble and water-soluble soils at a time has been developed. The results of developmental experiments and actual application are presented in this paper. (author)

  20. Terrain and building effects on the transport of radioactive material at a nuclear site

    International Nuclear Information System (INIS)

    Jeong, Hyojoon; Park, Misun; Jeong, Haesun; Hwang, Wontae; Kim, Eunhan; Han, Moonhee

    2014-01-01

    Highlights: • This study is to quantify the building and terrain effects on the atmospheric dispersion. • Statistical methods with AERMOD-PRIME and CFD were used. • To assess the risk in nuclear power plants, terrain and building effects have to be considered. - Abstract: This study identified the terrain and building effects on the atmospheric dispersion of radioactive materials at the Wolsong Nuclear Site. To analyze the atmospheric dispersion of radioactive materials, the AERMOD-PRIME model, CFD model and meteorological data from 2010 were used. The terrain and building effects on the atmospheric dispersion of radioactive materials within a 1 km radius of the site were statistically significant. The maximum concentration of the radioactive material increased by 7 times compared to the concentration when the terrain and building effects were not considered. It was found that the terrain and building influenced the decrease in the concentration of radioactive material in a concentric circle with a 914 m radius from the center of the site. The concentration of radioactive material in a concentric circle with a 350 m radius was two-times higher than the concentration estimated at the backside of the building, which is the downwind side, without any consideration of the terrain and building effects. In consideration of the Korean situation, in which multiple nuclear reactors are built on the same nuclear site, it is necessary to evaluate the risk that may affect workers and nearby residents by reflecting the terrain and building effects

  1. Discharge cleaning for a tokamak

    International Nuclear Information System (INIS)

    Ishii, Shigeyuki

    1983-01-01

    Various methods of discharge cleaning for tokamaks are described. The material of the first walls of tokamaks is usually stainless steel, inconel, titanium and so on. Hydrogen is exclusively used as the discharge gas. Glow discharge cleaning (GDC), Taylor discharge cleaning (TDC), and electron cyclotron resonance discharge cleaning (ECR-DC) are discussed in this paper. The cleaning by GDC is made by moving a movable anode to the center of a tokamak vassel. Taylor found the good cleaning effect of induced discharge by high pressure and low power discharge. This is called TDC. When the frequency of high frequency discharge in a magnetic field is equal to that of the electron cyclotron resonance, the break down potential is lowered if the pressure is sufficiently low. The ECR-CD is made by using this effect. In TDC and ECR-DC, the electron temperature, which has a close relation to the production rate of H 0 , can be controlled by the pressure. In GDC, the operating pressure was improved by the radio frequency glow (RG) method. However, there is still the danger of arcing. In case of GDC and ECR-DC, the position of plasma can be controlled, but not in case of TDC. The TDC is accepted by most of takamak devices in the world. (Kato, T.)

  2. Effectiveness of phytoremediation technologies to clean up of metalloids using three plant species in Iran.

    Science.gov (United States)

    Nejatzadeh-Barandozi, Fatemeh; Gholami-Borujeni, Fathollah

    2014-01-01

    Phytoremediation is a potential, innovative, and cost-effective technology for non-destructive remediation of heavy-metal contaminated soils. A field trial was conducted to evaluate the phytoremediation efficiencies of three plants and the effects of ethylenediaminetetraacetic acid (EDTA) or ammonium addition [(NH4)2SO4 and NH4NO3] for assisting removal of heavy metals (Pb, Hg, and Cd) from contaminated soil. The tested plants include Amaranthus retroflexus, Sorghum bicolor, and Lolium perrene. Results showed that maximum concentration of Pb, Hg, and Cd were detected in shoots of A. retroflexus, S. bicolor, and L. perrene at high concentrations in pH=6.2. The application of EDTA as a chelating agent to soil was the most efficient to enhance the phytoavailability of Pb, Hg and Cd. The concentrations of Pb, Hg, and Cd in the shoots of A. retroflexus treated with EDTA were 57 mg/kg, 14.1 mg/kg, and 30 mg/kg, respectively. Results indicated that among the three plants, A. retroflexus had great potential in phytoremediation of contaminated soils.

  3. Heterogeneous photocatalysis on construction materials: effect of catalyst properties on the efficiency for degrading NOx and self cleaning

    Directory of Open Access Journals (Sweden)

    Bengtsson, N.

    2014-05-01

    Full Text Available This paper analyzes the effect of some properties of different catalysts on the photocatalytic activity. The efficiency has been determined for two different processes: NOx abatement and self-cleaning for Rhodamine B and tobacco extract being, the TiO2 based photocatalyst, supported as coatings on white mortar. Eight different catalysts were tested, seven commercial ones and one home-made catalyst with improved visible light absorption properties. Additionally, some of them were submitted to exposition to water and/or calcinations to alter their physical properties. A kinetic approach was used to evaluate the photocatalytic activity, being the first reaction constant (for NO and just empirical constants (for self-cleaning the parameters used for the comparison of the different materials. As a result, the efficiency, even for ranking, is dependent on the type of contaminant used in the experiment. In general, NO oxidation and tobacco followed similar trends while no clear relations were found for Rhodamine B.En este trabajo se analiza el efecto de las propiedades de distintos catalizadores en la actividad fotocatalítica de degradación de NOx y autolimpieza, para Rodamina B y extracto de tabaco. Se han ensayado ocho fotocatalizadores, basados en TiO2 y soportados sobre mortero blanco; siete de ellos comerciales y uno sintetizado en el laboratorio con absorción mejorada en el visible. Adicionalmente, las propiedades físicas de algunos de ellos se alteraron mediante tratamientos con agua y/o por calcinación. La actividad fotocatalítica se ha evaluado mediante aproximación cinética, siendo la constante de reacción de primer orden (para NO y constantes empíricas de ajuste (para autolimpieza los parámetros de comparación entre materiales. Como resultado, la eficiencia depende del contaminante utilizado en el experimento de evaluación. En general, en este estudio, oxidación de NO y de extracto de tabaco presentan tendencias similares

  4. Effects of mechanical cleaning by manual brushing and abrasive blasting on lime render coatings on Architectural Heritage

    Directory of Open Access Journals (Sweden)

    Iglesias-Campos, M. A.

    2014-12-01

    Full Text Available This research studies the effects of mechanical cleaning by brushing and by abrasive blasting on the lime render coating of a façade. After analysing the properties of the material, the deposits to be removed and their possible influence on the treatment, different cleaning tests were made by manual brushing and by blasting with three varieties of abrasives at 45° and 75° angles, keeping the other parameters constant. Taking the restorer’s perspective as a starting point, and in order to fulfil the practical requirements of an intervention, tests were evaluated with macro-photography, USB digital microscope and stereomicroscope with 3D visualization and measurement. From the results can be concluded that abrasives with low friability and greater grain size than the space between mortar aggregates blasted at a 75° angle reduce the differential erosion compared to other abrasives; although manual brushing has less impact on the surface.En este trabajo se estudian los efectos de las limpiezas mecánicas con cepillado y con proyección de abrasivos sobre un revestimiento exterior de cal. Tras documentar las propiedades del material, de los depósitos superficiales y de su posible influencia en el tratamiento, se realizaron diferentes catas de limpieza con cepillado manual y con proyección de tres abrasivos con ángulos de 45° y 75° manteniendo constantes el resto de parámetros. Partiendo de la visión del conservador-restaurador y de un carácter práctico según las necesidades reales de intervención, los ensayos se evaluaron con macrofotografía, microscopio digital USB y microscopio estereoscópico con visualización y medición en 3D. De los resultados se determina que los abrasivos de baja friabilidad y granulometría mayor que el espacio entre los áridos del mortero proyectados con un ángulo de 75° reducen la erosión diferencial en comparación a otros abrasivos, aunque el cepillado manual altera menos la superficie.

  5. Assessment of effectiveness of Chinese aid in competence building and financing development in Sudan

    OpenAIRE

    Nour S.

    2014-01-01

    Assessment of effectiveness of Chinese aid in competence building and financing development in Sudan by S. Nour [abstract] This paper discusses the effectiveness of Chinese aid for competence building and financing development in Sudan using new primary data at the micro level. We find that Chinese aid and loans to Sudan caused mixed positive-negative impacts. The positive impact is competence building and providing alternative complementary sources of finance to complement domestic capital a...

  6. The effect of using low-polluting building materials on ventilation requirements and energy use in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wargocki, P.; Frontczak, M. (International Centre for Indoor Environment and Energy, Dept. of Mechanical Engineering, DTU, Kgs. Lyngby (DK)); Knudsen, Henrik N. (Danish Building Research Institute, Aalborg Univ., Hoersholm (DK))

    2007-07-01

    The main objective of the ongoing research project described in this paper was to study the potential for reducing energy used for ventilating buildings by using low-polluting building materials, without compromising the indoor air quality. To quantify this potential, the exposure-response relationships, i.e. the relationships between ventilation rate and perceived indoor air quality, were established for rooms furnished with different categories of polluting materials and the simulations of energy used for ventilation were carried out. The exposure-response relationships were based on a summary of data reported in the literature on exposure-response relationships for materials tested in laboratory settings in small-scale glass chambers, and in full-scale in climate chambers, test rooms or normal offices. New experiments were also considered in which the effect of using low-polluting materials on perceived air quality was examined in test rooms ventilated with different outdoor air supply rates, low-polluting materials being selected in small glass chambers. The results suggest that the exposure-response relationships vary between different building materials and that the perceived air quality can be improved considerably when polluting building materials are substituted with materials that pollute less. The preliminary energy simulations indicate that selecting low-polluting materials will result in considerable energy savings as a result of reducing the ventilation rates required to achieve acceptable indoor air quality. (au)

  7. Effect of flow velocity, substrate concentration and hydraulic cleaning on biofouling of reverse osmosis feed channels

    KAUST Repository

    Radu, Andrea I.

    2012-04-01

    A two-dimensional mathematical model coupling fluid dynamics, salt and substrate transport and biofilm development in time was used to investigate the effects of cross-flow velocity and substrate availability on biofouling in reverse osmosis (RO)/nanofiltration (NF) feed channels. Simulations performed in channels with or without spacer filaments describe how higher liquid velocities lead to less overall biomass amount in the channel by increasing the shear stress. In all studied cases at constant feed flow rate, biomass accumulation in the channel reached a steady state. Replicate simulation runs prove that the stochastic biomass attachment model does not affect the stationary biomass level achieved and has only a slight influence on the dynamics of biomass accumulation. Biofilm removal strategies based on velocity variations are evaluated. Numerical results indicate that sudden velocity increase could lead to biomass sloughing, followed however by biomass re-growth when returning to initial operating conditions. Simulations show particularities of substrate availability in membrane devices used for water treatment, e.g., the accumulation of rejected substrates at the membrane surface due to concentration polarization. Interestingly, with an increased biofilm thickness, the overall substrate consumption rate dominates over accumulation due to substrate concentration polarization, eventually leading to decreased substrate concentrations in the biofilm compared to bulk liquid. © 2012 Elsevier B.V.

  8. Effectiveness of a steam cleaning unit for disinfection in a veterinary hospital.

    Science.gov (United States)

    Wood, Cheryl L; Tanner, Benjamin D; Higgins, Laura A; Dennis, Jeffrey S; Luempert, Louis G

    2014-12-01

    To evaluate whether the application of steam to a variety of surface types in a veterinary hospital would effectively reduce the number of bacteria. 5 surface types. Steam was applied as a surface treatment for disinfection to 18 test sites of 5 surface types in a veterinary hospital. A pretreatment sample was obtained by collection of a swab specimen from the left side of each defined test surface. Steam disinfection was performed on the right side of each test surface, and a posttreatment sample was then collected in the same manner from the treated (right) side of each test surface. Total bacteria for pretreatment and posttreatment samples were quantified by heterotrophic plate counts and for Staphylococcus aureus, Pseudomonas spp, and total coliforms by counts on selective media. Significant reductions were observed in heterotrophic plate counts after steam application to dog runs and dog kennel floors. A significant reduction in counts of Pseudomonas spp was observed after steam application to tub sinks. Bacterial counts were reduced, but not significantly, on most other test surfaces that had adequate pretreatment counts for quantification. Development of health-care-associated infections is of increasing concern in human and veterinary medicine. The application of steam significantly reduced bacterial numbers on a variety of surfaces within a veterinary facility. Steam disinfection may prove to be an alternative or adjunct to chemical disinfection within veterinary practices.

  9. VPLS: an effective technology for building scalable transparent LAN services

    Science.gov (United States)

    Dong, Ximing; Yu, Shaohua

    2005-02-01

    Virtual Private LAN Service (VPLS) is generating considerable interest with enterprises and service providers as it offers multipoint transparent LAN service (TLS) over MPLS networks. This paper describes an effective technology - VPLS, which links virtual switch instances (VSIs) through MPLS to form an emulated Ethernet switch and build Scalable Transparent Lan Services. It first focuses on the architecture of VPLS with Ethernet bridging technique at the edge and MPLS at the core, then it tries to elucidate the data forwarding mechanism within VPLS domain, including learning and aging MAC addresses on a per LSP basis, flooding of unknown frames and replication for unknown, multicast, and broadcast frames. The loop-avoidance mechanism, known as split horizon forwarding, is also analyzed. Another important aspect of VPLS service is its basic operation, including autodiscovery and signaling, is discussed. From the perspective of efficiency and scalability the paper compares two important signaling mechanism, BGP and LDP, which are used to set up a PW between the PEs and bind the PWs to a particular VSI. With the extension of VPLS and the increase of full mesh of PWs between PE devices (n*(n-1)/2 PWs in all, a n2 complete problem), VPLS instance could have a large number of remote PE associations, resulting in an inefficient use of network bandwidth and system resources as the ingress PE has to replicate each frame and append MPLS labels for remote PE. So the latter part of this paper focuses on the scalability issue: the Hierarchical VPLS. Within the architecture of HVPLS, this paper addresses two ways to cope with a possibly large number of MAC addresses, which make VPLS operate more efficiently.

  10. Sequential Ground Motion Effects on the Behavior of a Base-Isolated RCC Building

    Directory of Open Access Journals (Sweden)

    Zhi Zheng

    2017-01-01

    Full Text Available The sequential ground motion effects on the dynamic responses of reinforced concrete containment (RCC buildings with typical isolators are studied in this paper. Although the base isolation technique is developed to guarantee the security and integrity of RCC buildings under single earthquakes, seismic behavior of base-isolated RCC buildings under sequential ground motions is deficient. Hence, an ensemble of as-recorded sequential ground motions is employed to study the effect of including aftershocks on the seismic evaluation of base-isolated RCC buildings. The results indicate that base isolation can significantly attenuate the earthquake shaking of the RCC building under not only single earthquakes but also seismic sequences. It is also found that the adverse aftershock effect on the RCC can be reduced due to the base isolation applied to the RCC. More importantly, the study indicates that disregarding aftershocks can induce significant underestimation of the isolator displacement for base-isolated RCC buildings.

  11. Clean Energy Infrastructure Educational Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hallinan, Kevin; Menart, James; Gilbert, Robert

    2012-08-31

    The Clean Energy Infrastructure Educational Initiative represents a collaborative effort by the University of Dayton, Wright State University and Sinclair Community College. This effort above all aimed to establish energy related programs at each of the universities while also providing outreach to the local, state-wide, and national communities. At the University of Dayton, the grant has aimed at: solidfying a newly created Master's program in Renewable and Clean Energy; helping to establish and staff a regional sustainability organization for SW Ohio. As well, as the prime grantee, the University of Dayton was responsible for insuring curricular sharing between WSU and the University of Dayton. Finally, the grant, through its support of graduate students, and through cooperation with the largest utilities in SW Ohio enabled a region-wide evaluation of over 10,000 commercial building buildings in order to identify the priority buildings in the region for energy reduction. In each, the grant has achieved success. The main focus of Wright State was to continue the development of graduate education in renewable and clean energy. Wright State has done this in a number of ways. First and foremost this was done by continuing the development of the new Renewable and Clean Energy Master's Degree program at Wright State . Development tasks included: continuing development of courses for the Renewable and Clean Energy Master's Degree, increasing the student enrollment, and increasing renewable and clean energy research work. The grant has enabled development and/or improvement of 7 courses. Collectively, the University of Dayton and WSU offer perhaps the most comprehensive list of courses in the renewable and clean energy area in the country. Because of this development, enrollment at WSU has increased from 4 students to 23. Secondly, the grant has helped to support student research aimed in the renewable and clean energy program. The grant helped to solidify

  12. Activity measurement and effective dose modelling of natural radionuclides in building material

    International Nuclear Information System (INIS)

    Maringer, F.J.; Baumgartner, A.; Rechberger, F.; Seidel, C.; Stietka, M.

    2013-01-01

    In this paper the assessment of natural radionuclides' activity concentration in building materials, calibration requirements and related indoor exposure dose models is presented. Particular attention is turned to specific improvements in low-level gamma-ray spectrometry to determine the activity concentration of necessary natural radionuclides in building materials with adequate measurement uncertainties. Different approaches for the modelling of the effective dose indoor due to external radiation resulted from natural radionuclides in building material and results of actual building material assessments are shown. - Highlights: • Dose models for indoor radiation exposure due to natural radionuclides in building materials. • Strategies and methods in radionuclide metrology, activity measurement and dose modelling. • Selection of appropriate parameters in radiation protection standards for building materials. • Scientific-based limitations of indoor exposure due to natural radionuclides in building materials

  13. Effect of the Building Act 2011 on compliance costs in Western Australia

    Directory of Open Access Journals (Sweden)

    Elizabeth Bazen

    2014-06-01

    Full Text Available  The Building Act 2011 commenced in Western Australia on 2 April 2012. It introduced private certification for design and construction compliance, and reduced fees and timeframes for local governments to issue permits. This research project assessed the effect of the Act on the time and cost of building approvals in WA, using an internet-based, self-completion survey to obtain feedback from people on their experience of the new building approvals process.   This research compared the cost of approval for 16 building projects under the new and old approvals processes. The research concluded that the new approvals process appears to be cost-neutral for the building industry as a whole. However, the cost of approval for the 11 building projects studied valued up to $1 million, particularly alterations to existing buildings, is an average of 4.0 times greater under the new approvals process.

  14. THE DETECTION OF THE NECESSARY CONDITIONS OF EFFECTIVE FUNCTIONING OF THE BALL CLEANING SYSTEM OF THE TUBES OF STEAM TURBINE CONDENSERS. Part 1

    Directory of Open Access Journals (Sweden)

    A. G. Gerasimova

    2017-01-01

    Full Text Available A problem of an increase of the power of turbine by improving heat transfer in condensers of steam turbines is considered in the article as a topical one. The analysis of contamination of the internal surfaces of cooling tubes and of the influence of pollution on the process of heat transfer in turbine condensers has been fulfilled. The existing method of cleaning of condenser tubes with the use of porous elastic balls of sponge rubber that is implemented on a number of large thermal power plants and state region power plants of the Republic of Belarus is examined. In the operation of the ball cleaning system a significant drawback has been revealed, viz. a low efficiency of this method due to the failure to comply with preparation the system of circulating water for operation. Also, a certain imperfection of ball cleaning system technology has been determined. One of the prerequisites for the effective functioning of the ball cleaning system is a certain degree of purity of the pipe system of the condenser, characterized by the coefficient of purity. To determine the effectiveness of ball cleaning system a series of experiments on the launching of porous rubber balls in the pipe system of the main and the embedded bunches of the T-250/300-240 UTMZ turbine has been produced. Immediately before the experiments hydraulic cleaning of the tubes of the condenser by a high-pressure installation were carried out. During the experiments, records of the number of downloaded porous rubber balls, of the number of rubber balls captured in a loading chamber, and of the number of rubber balls that remained in a calibration device were kept. A large proportion of default of the balls caused by the presence of residues of the carbonate sediments, that obstruct the movement of porous rubber balls in the tubes of the condenser, was determined. The presence of carbonate deposits in the tubes of the condenser indicates a lack of effectiveness of antiscale treatment

  15. Cleaning Management in Higher Education: Value for Money Study.

    Science.gov (United States)

    Scottish Higher Education Funding Council, Edinburgh.

    This report identifies key management issues for senior managers and heads of cleaning departments in developing and reviewing cleaning services to support improvement and enhance cost effectiveness. The cleaning costs incurred by higher education institutions (HEIs) represent 2.7 percent of the total spent nationally on cleaning services for both…

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... has been rented. This feature is not available right now. Please try again later. Published on May ... 34 How The Clean Hands - Safe Hands System Works - Duration: 3:38. Clean Hands-Safe Hands 5, ...

  17. Chemical cleaning review

    International Nuclear Information System (INIS)

    Dow, B.L.; Thomas, R.C.

    1995-01-01

    Three main chemical processes for cleaning steam generators have evolved from the early work of the industry. Of the more than 50 chemical cleanings carried out to date most have been considered a success by the utilities performing them. (author)

  18. Assessment of effectiveness of Chinese aid in competence building and financing development in Sudan

    NARCIS (Netherlands)

    Nour, S.

    2014-01-01

    Assessment of effectiveness of Chinese aid in competence building and financing development in Sudan by S. Nour [abstract] This paper discusses the effectiveness of Chinese aid for competence building and financing development in Sudan using new primary data at the micro level. We find that Chinese

  19. Efficient methods of piping cleaning

    Directory of Open Access Journals (Sweden)

    Orlov Vladimir Aleksandrovich

    2014-01-01

    Full Text Available The article contains the analysis of the efficient methods of piping cleaning of water supply and sanitation systems. Special attention is paid to the ice cleaning method, in course of which biological foil and various mineral and organic deposits are removed due to the ice crust buildup on the inner surface of water supply and drainage pipes. These impurities are responsible for the deterioration of the organoleptic properties of the transported drinking water or narrowing cross-section of drainage pipes. The co-authors emphasize that the use of ice compared to other methods of pipe cleaning has a number of advantages due to the relative simplicity and cheapness of the process, economical efficiency and lack of environmental risk. The equipment for performing ice cleaning is presented, its technological options, terms of cleansing operations, as well as the volumes of disposed pollution per unit length of the water supply and drainage pipelines. It is noted that ice cleaning requires careful planning in the process of cooking ice and in the process of its supply in the pipe. There are specific requirements to its quality. In particular, when you clean drinking water system the ice applied should be hygienically clean and meet sanitary requirements.In pilot projects, in particular, quantitative and qualitative analysis of sediments adsorbed by ice is conducted, as well as temperature and the duration of the process. The degree of pollution of the pipeline was estimated by the volume of the remote sediment on 1 km of pipeline. Cleaning pipelines using ice can be considered one of the methods of trenchless technologies, being a significant alternative to traditional methods of cleaning the pipes. The method can be applied in urban pipeline systems of drinking water supply for the diameters of 100—600 mm, and also to diversion collectors. In the world today 450 km of pipelines are subject to ice cleaning method.Ice cleaning method is simple

  20. The Effects of Two Different Cleaning and Disinfection Programs on Broiler Performance and Microbiological Status of Broiler Houses

    Directory of Open Access Journals (Sweden)

    MFC Burbarelli

    2015-12-01

    Full Text Available ABSTRACT The objective of this study was to investigate the influence of two cleaning and disinfection programs on broiler performance and on the microbiological status of the facilities. This trial was an observational study of comparative character. Two experiments were conducted, with 960 birds each. Both experiments were carried out in a positive-pressure broiler house. Broilers were distributed in pens equipped with a bell drinker and a tube feeder each. In the first experiment, new wood shavings were used as litter material, and in the second, reused wood shavings were used. Two treatments with16 replicates of 30 birds each were evaluated. The regular treatment consisted of dry and wet organic matter removal, followed by washing. The European treatment consisted of dry organic matter removal, humidification, washing with water under high pressure, detergent application, rinsing, and application of two combined disinfectants: glutaraldehyde 250g/L + formaldehyde 185g/L; p-chlor-m-cresol 210 g/L. Biosecurity measures were adopted during daily management tasks to prevent cross contamination between treatments. The effectiveness of the treatments was evaluated by microbiological analysis performed before and after treatment applications, as well as by broiler performance results. Live performance results were similar between both treatments when broilers were reared on new litter. When reused word-shavings were used as litter material, the European treatment promoted better broiler performance. The European treatment was more effective than the regular treatment in reducing total microbial counts in the facilities when reused wood shavings were used as litter material, and positively influenced broiler performance.

  1. Sustainable school infrastructure through effective innovative building technology selection

    CSIR Research Space (South Africa)

    Mphahlele, C

    2014-10-01

    Full Text Available The aim of the paper is to provide an overview of a model proposed for the selection Innovative Building Technologies (IBTs) and procurement of services supporting the erection of the IBTs that will ensure the construction of a sustainable school...

  2. Effects of different building blocks designs on the statistical ...

    African Journals Online (AJOL)

    Tholang T. Mokhele

    Enumeration Areas (EAs), Small Area Layers (SALs) and SubPlaces) from the 2001 census data were used as building blocks for the generation of census output areas with AZTool program in both rural and urban areas of South Africa. One way-Analysis of Variance (ANOVA) was also performed to determine statistical ...

  3. Salinization effects on the water sorption of porous building materials

    NARCIS (Netherlands)

    Brocken, H.J.P.; Rook, W.; Adan, O.C.G.

    1999-01-01

    The interaction of salt transport and moisture transport plays a crucial role in some deterioration mechanisms of porous building materials. For this reason it has been an important research subject for mant' years. Yet most research was still complicated by the lack of experimental techniques

  4. Building the capacity of agricultural extension personnel for effective ...

    African Journals Online (AJOL)

    This paper strongly recommends immediate recruitment of new hands as well as full implementation of a well-designed capacity building programme so as to ensure a sustainable extension service delivery system where extension personnel can operate in the expected commercial (agriculture-driven) economy. Keywords: ...

  5. The protection effects of buildings in front of nuclear fall-out

    International Nuclear Information System (INIS)

    Mueck, K.; Lovranich, E.; Steger, F.

    1995-02-01

    In order to adopt appropriate countermeasures to protect the public in case of a wide-spread contamination after a severe reactor accident, a profound knowledge of the dose to be expected of the dose reduction to be expected if a specific countermeasure is adopted is required. Since external radiation contributes a major fraction of up to 80 % to the total dose, the interest is focussed on the reduction of external dose by staying indoors. For this purpose measurements of the dose reduction by external radiation were performed in 40 residential rooms in Vienna which were chosen according to their fraction of the Viennese building structure. They were performed by measurement of the reduction of the gamma-flux in the interior of buildings compared to the gamma-flux outside. Measurements were carried out by a HPGe-detector which was positioned 1 m above ground. The observed dose reduction factors amounted to 0.013 on the average (protection factor 78,7 '+-' 49,7), with the protection factors of the investigated building types ranging from 6,5 (single house in garden) to 122,9 (edicifices of the turn of the century). The observed protection factors do not include the dose reduction by dense arrangement of buildings in urban areas which has to be considered separately. The dose reduction due to different radionuclide mixtures after severe reactor accidents was also investigated. Factors similar to that observed for Cs-137 were found. The maximum deviations amounted only 12 % and therefore may be neglected in the consideration of protective measures. Additional measurements were performed with the same detector shielded by lead on all sides to determine the contribution of the interior contamination. A contribution of between < 10 % to 50 % to the external dose in the interior of buildings was observed. Measures to reduce the inner contamination in rooms (closing of windows and doors, cleaning upon entering the building interior) in case of an event are therefore

  6. The effects of oil contamination and cleaning on sea otters (Enhydra lutris); II. Metabolism, thermoregulation, and behavior

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R W; Williams, T M; Thomas, J A; DasSelein, R A; Cornell, L H [Hubbs marine Research Center, San Diego, CA (USA)

    1988-12-01

    The purpose of this study was to develop a method to clean and rehabilitate sea otters that might become contaminated during an oil spill and to determine which physiological and behavioral factors were important in restoring the insulation provided by the fur. Tests were conducted on 12 sea otters; measurements of average metabolic rate, core body temperature, behavior, and squalene concentration on the fur were made before oiling 1-3 days after 20% of the body surface area was covered with fresh crude oil, and after cleaning. Under base-line conditions in water at 13{degrees}C, average metabolic rate was 8.0 W/kg, core body temperature was 38.9{degrees}C, and whole body thermal conductance was 10.7 W/(m2/{degrees}C). The squalene concentration on the fur averaged 3.7 mg/g fur. Oiling increased thermal conductance 1.8 times. To compensate for the loss of insulation and maintain a normal core body temperature (39{degrees}C), the otters increased average metabolic rate (1.9 times) through voluntary activity and shivering; the time spent grooming and swimming increased 1.7 times. Using detergent, the oiled fur could be cleaned during 40 min. of washing and rinsing. Grooming activity by the otters was essential for restoring the water-repellent quality of the fur. Core body temperature, average metabolic rate, and thermal conductance returned to base-line levels 3-6 days after cleaning. Squalene was removed by cleaning and did not return to normal levels in the oiled area after 7 days. Veterinary care was important to keep the otters healthy. At least 1-2 weeks should be allowed for otters to restore the insulation of their fur and for recovery from the stress of oiling and cleaning. 29 ref., 5 figs., 6 tabs.

  7. Hydration effects on the electronic properties of eumelanin building blocks

    International Nuclear Information System (INIS)

    Assis Oliveira, Leonardo Bruno; Fonseca, Tertius L.; Costa Cabral, Benedito J.; Coutinho, Kaline; Canuto, Sylvio

    2016-01-01

    Theoretical results for the electronic properties of eumelanin building blocks in the gas phase and water are presented. The building blocks presently investigated include the monomeric species DHI (5,6-dihydroxyindole) or hydroquinone (HQ), DHICA (5,6-dihydroxyindole-2-carboxylic acid), indolequinone (IQ), quinone methide (MQ), two covalently bonded dimers [HM ≡ HQ + MQ and IM ≡ IQ + MQ], and two tetramers [HMIM ≡ HQ + IM, IMIM ≡ IM + IM]. The electronic properties in water were determined by carrying out sequential Monte Carlo/time dependent density functional theory calculations. The results illustrate the role played by hydrogen bonding and electrostatic interactions in the electronic properties of eumelanin building blocks in a polar environment. In water, the dipole moments of monomeric species are significantly increased ([54–79]%) relative to their gas phase values. Recently, it has been proposed that the observed enhancement of the higher-energy absorption intensity in eumelanin can be explained by excitonic coupling among eumelanin protomolecules [C.-T. Chen et al., Nat. Commun. 5, 3859 (2014)]. Here, we are providing evidence that for DHICA, IQ, and HMIM, the electronic absorption toward the higher-energy end of the spectrum ([180–220] nm) is enhanced by long-range Coulombic interactions with the water environment. It was verified that by superposing the absorption spectra of different eumelanin building blocks corresponding to the monomers, dimers, and tetramers in liquid water, the behaviour of the experimental spectrum, which is characterised by a nearly monotonic decay from the ultraviolet to the infrared, is qualitatively reproduced. This result is in keeping with a “chemical disorder model,” where the broadband absorption of eumelanin pigments is determined by the superposition of the spectra associated with the monomeric and oligomeric building blocks.

  8. Hydration effects on the electronic properties of eumelanin building blocks

    Energy Technology Data Exchange (ETDEWEB)

    Assis Oliveira, Leonardo Bruno [Instituto de Física da Universidade Federal de Goiás, 74690-900 Goiânia, GO (Brazil); Departamento de Física - CEPAE, Universidade Federal de Goiás, 74690-900 Goiânia, GO (Brazil); Escola de Ciências Exatas e da Computação, Pontifícia Universidade Católica de Goiás, 74605-010 Goiânia, GO (Brazil); Fonseca, Tertius L. [Instituto de Física da Universidade Federal de Goiás, 74690-900 Goiânia, GO (Brazil); Costa Cabral, Benedito J., E-mail: ben@cii.fc.ul.pt [Grupo de Física Matemática da Universidade de Lisboa and Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa (Portugal); Coutinho, Kaline; Canuto, Sylvio [Instituto de Física da Universidade de São Paulo, CP 66318, 05314-970 São Paulo, SP (Brazil)

    2016-08-28

    Theoretical results for the electronic properties of eumelanin building blocks in the gas phase and water are presented. The building blocks presently investigated include the monomeric species DHI (5,6-dihydroxyindole) or hydroquinone (HQ), DHICA (5,6-dihydroxyindole-2-carboxylic acid), indolequinone (IQ), quinone methide (MQ), two covalently bonded dimers [HM ≡ HQ + MQ and IM ≡ IQ + MQ], and two tetramers [HMIM ≡ HQ + IM, IMIM ≡ IM + IM]. The electronic properties in water were determined by carrying out sequential Monte Carlo/time dependent density functional theory calculations. The results illustrate the role played by hydrogen bonding and electrostatic interactions in the electronic properties of eumelanin building blocks in a polar environment. In water, the dipole moments of monomeric species are significantly increased ([54–79]%) relative to their gas phase values. Recently, it has been proposed that the observed enhancement of the higher-energy absorption intensity in eumelanin can be explained by excitonic coupling among eumelanin protomolecules [C.-T. Chen et al., Nat. Commun. 5, 3859 (2014)]. Here, we are providing evidence that for DHICA, IQ, and HMIM, the electronic absorption toward the higher-energy end of the spectrum ([180–220] nm) is enhanced by long-range Coulombic interactions with the water environment. It was verified that by superposing the absorption spectra of different eumelanin building blocks corresponding to the monomers, dimers, and tetramers in liquid water, the behaviour of the experimental spectrum, which is characterised by a nearly monotonic decay from the ultraviolet to the infrared, is qualitatively reproduced. This result is in keeping with a “chemical disorder model,” where the broadband absorption of eumelanin pigments is determined by the superposition of the spectra associated with the monomeric and oligomeric building blocks.

  9. THE EFFECT OF DEGRADATION PROCESSES ON THE SERVICEABILITY OF BUILDING MATERIALS OF HISTORIC BUILDINGS

    Directory of Open Access Journals (Sweden)

    Jiří Witzany

    2016-10-01

    Full Text Available The article presents an analysis of degradation processes and partial results of an experimental research into materials and structures exposed to the effects of external environments with an emphasis on the effects of moisture and chemical degradation processes on major mechanical properties of sandstone.

  10. Urban weather data and building models for the inclusion of the urban heat island effect in building performance simulation.

    Science.gov (United States)

    Palme, M; Inostroza, L; Villacreses, G; Lobato, A; Carrasco, C

    2017-10-01

    This data article presents files supporting calculation for urban heat island (UHI) inclusion in building performance simulation (BPS). Methodology is used in the research article "From urban climate to energy consumption. Enhancing building performance simulation by including the urban heat island effect" (Palme et al., 2017) [1]. In this research, a Geographical Information System (GIS) study is done in order to statistically represent the most important urban scenarios of four South-American cities (Guayaquil, Lima, Antofagasta and Valparaíso). Then, a Principal Component Analysis (PCA) is done to obtain reference Urban Tissues Categories (UTC) to be used in urban weather simulation. The urban weather files are generated by using the Urban Weather Generator (UWG) software (version 4.1 beta). Finally, BPS is run out with the Transient System Simulation (TRNSYS) software (version 17). In this data paper, four sets of data are presented: 1) PCA data (excel) to explain how to group different urban samples in representative UTC; 2) UWG data (text) to reproduce the Urban Weather Generation for the UTC used in the four cities (4 UTC in Lima, Guayaquil, Antofagasta and 5 UTC in Valparaíso); 3) weather data (text) with the resulting rural and urban weather; 4) BPS models (text) data containing the TRNSYS models (four building models).

  11. Clean-up and matrix effect in LC-MS/MS analysis of food of plant origin for high polar herbicides.

    Science.gov (United States)

    Kaczyński, Piotr

    2017-09-01

    This study reports an innovative and sensitive procedure for analysis of difficult high polar herbicides (HPH) in diverse foods of plant origin. The QuPPe (Quick Polar Pesticides) method followed by determination by LC-MS/MS was modified. Chromatographic conditions, extraction, clean-up, and matrix effect were studied. Several liquid chromatography stationary and mobile phases were evaluated, and it was found that hydrophilic interaction chromatography (HILIC) gives good retention and sensitivity. An acidified methanol-water mixture was used as an effective extraction solvent of eleven HPH. Dispersive solid-phase clean-up sorbents (C18, GCB, Florisil, chitosan and graphene) were evaluated. The efficiency of the method was examined using data on recovery, precision and matrix effects. High extraction yields were achieved, and recoveries were within the 64-97% range with relative standard deviations <20% for all HPH in all commodities. Low matrix effects were observed when graphene was used during clean-up of onion extract and when chitosan was used for wheat, potato and pea extract. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Histological evaluation of the cleaning effectiveness of two reciprocating single-file systems in severely curved root canals: Reciproc versus WaveOne.

    Science.gov (United States)

    Carvalho, Maira de Souza; Junior, Emílio Carlos Sponchiado; Bitencourt Garrido, Angela Delfina; Roberti Garcia, Lucas da Fonseca; Franco Marques, André Augusto

    2015-01-01

    The aim of this study was to evaluate the cleaning effectiveness achieved with two reciprocating single-file systems in severely curved root canals: Reciproc and WaveOne. Twenty-five mesial roots of mandibular molars were randomly separated into two groups, according to the instrumentation system used. The negative control group consisted of five specimens that were not instrumented. The mesial canals (buccal and lingual) in Reciproc Group were instrumented with file R25 and the WaveOne group with the Primary file. The samples were submitted to histological processing and analyzed under a digital microscope. The WaveOne group presented a larger amount of debris than the Reciproc Group, however, without statistically significant difference (P > 0.05). A larger amount of debris in the control group was observed, with statistically significant difference to Reciproc and WaveOne groups (P file instrumentation systems presented similar effectiveness for root canal cleaning.

  13. The effect of humus on biological cleaning of soils - association of harmful organic substances from mineral oil contaminators

    International Nuclear Information System (INIS)

    Richnow, H.H.; Seifert, R.; Michaelis, W.

    1993-01-01

    The association of organic harmful substances and particularly their metabolites with the humin fraction is a process which has great ecological importance. The knowledge of the type and extent of such associations of harmful substances with the humin fraction of the soil plays a central part in the assessment of loading by harmful substances or the success of biological cleaning up measures. (orig.) [de

  14. Activity measurement and effective dose modelling of natural radionuclides in building material.

    Science.gov (United States)

    Maringer, F J; Baumgartner, A; Rechberger, F; Seidel, C; Stietka, M

    2013-11-01

    In this paper the assessment of natural radionuclides' activity concentration in building materials, calibration requirements and related indoor exposure dose models is presented. Particular attention is turned to specific improvements in low-level gamma-ray spectrometry to determine the activity concentration of necessary natural radionuclides in building materials with adequate measurement uncertainties. Different approaches for the modelling of the effective dose indoor due to external radiation resulted from natural radionuclides in building material and results of actual building material assessments are shown. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Effects of team-building on communication and teamwork among nursing students.

    Science.gov (United States)

    Yi, Y J

    2016-03-01

    The aim of this study was to assess the effects of team-building on communication and teamwork (i.e. teamwork skills and team effectiveness) among nursing students. Team-building is effective for improving communication and teamwork among the nursing organization. However, the effects of team-building are not well known especially in Korea. This study used a quasi-experimental design. The sample was composed of 195 junior-year nursing students in Korea. The experimental group (100 subjects) participated in team-building activities over a 100-day period, whereas no intervention was applied to the control group (95 subjects). Pretest was conducted in both groups, and post-test was conducted after the 100-day intervention. The pre-post change in mean communication competence score did not differ between the two groups. However, the mean scores for teamwork skills and team effectiveness differed significantly between the two groups after team-building activity. This study was not a double-blind test, and randomized sampling was not implemented. Caution should thus be used when interpreting the findings. Team-building activities were effective for improving the teamwork skills and team effectiveness among Korean nursing students. It is recommended that team-building activities should be included regularly as an integral educational approach in nursing education. The findings suggest that suggests that team-building for improving communication and teamwork should be designated as one of the required criteria for nursing college programme accreditation in many countries, including Korea. However team-building requires further testing to verify this across cultures. Nurses need to receive formal team-building training for improving communication and teamwork, and formal education should be included in their job training schedule. It is recommended that communication competence and teamwork be used as one of job performance evaluations in their workplace. © 2015

  16. Pesticide analysis in coffee leaves using a quick, easy, cheap, effective, rugged and safe approach and liquid chromatography tandem mass spectrometry: Optimization of the clean-up step.

    Science.gov (United States)

    Trevisan, Maria Teresa Salles; Owen, Robert Wyn; Calatayud-Vernich, Pau; Breuer, Andrea; Picó, Yolanda

    2017-08-25

    An analytical method using a quick, easy, cheap, effective, rugged and safe (QuEChERS) procedure for multi-residue determination of 52 pesticides in coffee leaf extractshas been developed and validated according to SANTE/11945/2015 guidelines. Different sorbent combinations for dispersive solid phase extraction (d-SPE) clean-up as well as dispersive liquid-liquid microextraction (DLLME) were tested. The relative standard deviations (RSDs) for the recovery of 87-94% of pesticides added to coffee leaf extracts,was ≤20% for samples spiked at concentrations up to 50ng*g -1 depending on the clean-up procedures. However, samples spiked with a 100ng*g -1 pesticide mixture gave RSDs>20% for most pesticides when d-SPE was carried out adding Supelclean ENVI-Carb 120/400. To explain this fact,the secondary metabolic profile was analyzed in all the extraction and clean-up procedures. Only in the clean-up procedure with the addition of Supel QuE Z-Sep+, does caffeine show a constant adsorption between blank and spiked samples. In other clean-up procedures, the amount of caffeine was higher in those samples spiked with pesticides. This indicates competition between caffeine and pesticides for adsorption to the sorbent. Addition of Supel QuE Z-Sep+ to the procedure revealed only a 32% matrix effect, whereas using PSA+ C18 the matrix effect was close to 97%. The process efficiency is up to 54% with the addition of Supel QuE Z-Sep+ and just up to 7% for the other clean-up procedures. The method was successfully tested in coffee leaves from different types of cultivars. Pesticides were not detected in organic coffee leaf extracts, but thiametoxan was clearly detected in 50% of coffee leaf extracts harvested from coffee trees grown under traditional conditions as determined by UHPLC-TOFMSLC/QqTOF-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The effect of building regulations on energy consumption in single family houses in Denmark

    DEFF Research Database (Denmark)

    Kjærbye, Vibeke; Larsen, Anders; Togeby, Mikael

    This paper explores how changes in regulatory requirements for energy efficiency in buildings (in the US also known as building energy codes) affect household energy consumption. The focus in this paper is on natural gas consumption by Danish single-family owner-occupied houses. Unlike most other...... advanced econometric methods we examine differences in heating energy consumption due to different building regulation requirements at the time of house construction. As for the effect of the building regulation, we find that changes in Danish building regulations have led to significant reductions...... in energy used for heating. The latest revision of the Danish building regulation covered by this paper is that of 1998. This revision has resulted in a 7% reduction in natural gas consumption....

  18. Northeast Clean Energy Application Center

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, Tom [Pace Univ., New York, NY (United States)

    2013-09-30

    From October 1, 2009 through September 30, 2013 (“contract period”), the Northeast Clean Energy Application Center (“NE-CEAC”) worked in New York and New England (Connecticut, Rhode Island, Vermont, Massachusetts, New Hampshire, and Maine) to create a more robust market for the deployment of clean energy technologies (CETs) including combined heat and power (CHP), district energy systems (DES), and waste heat recovery (WHR) systems through the provision of technical assistance, education and outreach, and strategic market analysis and support for decision-makers. CHP, DES, and WHR can help reduce greenhouse gas emissions, reduce electrical and thermal energy costs, and provide more reliable energy for users throughout the United States. The NE-CEAC’s efforts in the provision of technical assistance, education and outreach, and strategic market analysis and support for decision-makers helped advance the market for CETs in the Northeast thereby helping the region move towards the following outcomes: Reduction of greenhouse gas emissions and criteria pollutants; Improvements in energy efficiency resulting in lower costs of doing business; Productivity gains in industry and efficiency gains in buildings; Lower regional energy costs; Strengthened energy security; Enhanced consumer choice; Reduced price risks for end-users; and Economic development effects keeping more jobs and more income in our regional economy Over the contract period, NE-CEAC provided technical assistance to approximately 56 different potential end-users that were interested in CHP and other CETs for their facility or facilities. Of these 56 potential end-users, five new CHP projects totaling over 60 MW of install capacity became operational during the contract period. The NE-CEAC helped host numerous target market workshops, trainings, and webinars; and NE-CEAC staff delivered presentations at many other workshops and conferences. In total, over 60 different workshops, conferences

  19. Lighting and energy supply for heating in building using algae power

    African Journals Online (AJOL)

    A significant proportion of this energy is consumed in buildings. Therefore, access to clean and healthy energy in buildings can have a significant role in improving environmental conditions. This article wants to present the definition and the usage of one of the energy resources made by nanotechnology and its effect on ...

  20. Who is afraid of the big bad ban? An evaluation of the effects of the Spanish clean air law on expenditure at hospitality venues

    OpenAIRE

    Garcia Villar, Jaume; López-Nicolás, Ángel

    2014-01-01

    Background:In January 2011 Spain modified clean air legislation in force since 2006, removing all existing exceptions applicable to hospitality venues. Although this legal reform was backed by all political parties with parliamentary representation, the government's initiative was contested by the tobacco industry and its allies in the hospitality industry. One of the most voiced arguments against the reform was its potentially disruptive effect on the revenue of hospitality venues. This pape...

  1. The effect of micro air movement on the heat and moisture characteristics of building constructions

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2010-01-01

    The research focuses on the effect of air movement through building constructions. Although the typical air movement inside building constructions is quite small (velocity is of order ~10-5 m/s), this research shows the impact on the heat and moisture characteristics. The paper presents a case study

  2. The effect of micro air movement on the heat and moisture characteristics of building constructions

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2008-01-01

    The research focuses on the effect of air movement through building constructions. Although the typical air movement inside building constructions is quite small (velocity is of order ~10-5 m/s), this research shows the impact on the heat and moisture characteristics. The paper presents a case study

  3. The Effect of Pair Work on a Word-Building Task

    Science.gov (United States)

    Baleghizadeh, Sasan

    2010-01-01

    This paper reports on a study that was carried out to investigate the effect of pair work on a word-building task in two EFL classes. Forty Iranian adult students participated in this study. The participants in the experimental group completed the word-building task in pairs following the Think-Pair-Share technique, whereas the participants in the…

  4. Daylong Effect of Tooth Brushing or Combination Tooth Brushing and Tongue Cleaning Using Antiplaque®Toothpaste on Volatile Sulphur Compound Levels

    Directory of Open Access Journals (Sweden)

    Indriasti Indah Wardhany

    2013-07-01

    Full Text Available Objective: to determine the daylong effect of Antiplaque® toothpaste active copound and the effect of tooth brushing or combination of tooth brushing and tongue cleaning on Volatile Sulphur Compounds (VSC levels. Methods: Clinical experimental double blinded microbiological and clinical examination. Subjects mainly from dental faculty student with or without a chief complain of halitosis. One hundred and twenty subjects were divided into four groups that consist of thirty samples each group. Two group are treatment subjects were divided into four groups that consist thirty samples each group. Two groups are treatment groups using Antiplaque® toothpaste and two groups are control groups using placebo toothpaste. The daylong effects of VSC levels are measured by Halimeter and organoleptic. The intraoral status were measured including periodontal status and tongue index. Result: There are a reduction of VSC levels in both treatment and control group, but the reduction only significant in group using Antiplaque® toothpaste (Wilcoxon signed rank test, p<0.05. There are a reduction of VSC levels in both treatment using Antiplaque® toothpaste, but the combination of tooth brushing and tongue cleaning reduced VSC levels significantly lower than tooth brushing treatment (Mann Whitney U test, P,0.05. Conclusion: Tooth brushing and tongue cleaning using Antiplaque® toothpaste significantly reduced VSC levels.DOI: 10.14693/jdi.v16i2.95

  5. Computational fluid dynamics simulation of wind-driven inter-unit dispersion around multi-storey buildings: Upstream building effect

    DEFF Research Database (Denmark)

    Ai, Zhengtao; Mak, C.M.; Dai, Y.W.

    2017-01-01

    of such changed airflow patterns on inter-unit dispersion characteristics around a multi-storey building due to wind effect. Computational fluid dynamics (CFD) method in the framework of Reynolds-averaged Navier-stokes modelling was employed to predict the coupled outdoor and indoor airflow field, and the tracer...... gas technique was used to simulate the dispersion of infectious agents between units. Based on the predicted concentration field, a mass conservation based parameter, namely re-entry ratio, was used to evaluate quantitatively the inter-unit dispersion possibilities and thus assess risks along...

  6. The effects of buildings on low-level atmospheric discharges

    International Nuclear Information System (INIS)

    Foster, P.M.; Robins, A.G.

    1985-01-01

    The building wake dispersion study undertaken by the CEGB was aimed at providing a coherent assessment of both analytical and physical modelling techniques from comparisons with full scale data obtained at an operational nuclear power station in well mixed meteorological conditions. The project was divided into three parts: (i) to develop the necessary full scale techniques for quantitative plume observations at ground level and above, (ii) to conduct a range of plume dispersion and mapping experiments at a suitable nuclear site at both full and model scales, (iii) to assess the results of (ii) and compare them with analytical modelling predictions. A dual smoke tracer and SF 6 gas tracer was chosen for the full scale trials. They were conducted at Oldbury Power Station. The complementary wind tunnel investigations were conducted in the CEGB wind tunnel. The full scale measurements provided data on the elevated plume structure and on the downwind range dependence of plume dimensions and concentration over a limited range of wind directions. Comparison with the corresponding results from the wind tunnel study was generally good. However, in the lightest winds studied (around 5 ms -1 ) differences were observed. A selection of simple analytic models was subjected to further analysis using the extensive data set from the wind tunnel study. This showed that close to the building plume behaviour was complex and produced large variations in ground level centre line concentration with varying source position and wind direction. The analytic models do not predict this but only attempt to represent the bulk behaviour. However, beyond about 10 building heights range the plume behaviour simplifies sufficiently for acceptably accurate predictions to be achieved

  7. The effects of buildings on low-level atmospheric discharges

    International Nuclear Information System (INIS)

    Foster, P.M.; Robins, A.G.

    1985-01-01

    This study of building influenced dispersion provides a coherent assessment of both analytical and physical modelling techniques from comparisons with full scale data obtained at an operational nuclear power station. Plume sections showing the elevated structure and dilution of full scale plumes have been obtained using scanning lidar equipment and dual smoke/SF 6 tracers. Complementary wind tunnel studies have been made and validation studies between full and model scales have been carried out. The limitations of some popular simple dispersion models have been assessed from comparisons with the measurements. (author)

  8. Energy Code Compliance in a Detailed Commercial Building Sample: The Effects of Missing Data

    Energy Technology Data Exchange (ETDEWEB)

    Biyani, Rahul K.; Richman, Eric E.

    2003-09-30

    Most commercial buildings in the U.S. are required by State or local jurisdiction to meet energy standards. The enforcement of these standards is not well known and building practice without them on a national scale is also little understood. To provide an understanding of these issues, a database has been developed at PNNL that includes detailed energy related building characteristics of 162 commercial buildings from across the country. For this analysis, the COMcheck? compliance software (developed at PNNL) was used to assess compliance with energy codes among these buildings. Data from the database for each building provided the program input with percentage energy compliance to the ASHRAE/IESNA Standard 90.1-1999 energy as the output. During the data input process it was discovered that some essential data for showing compliance of the building envelope was missed and defaults had to be developed to provide complete compliance information. This need for defaults for some data inputs raised the question of what the effect on documenting compliance could be due to missing data. To help answer this question a data collection effort was completed to assess potential differences. Using the program Dodge View, as much of the missing envelope data as possible was collected from the building plans and the database input was again run through COMcheck?. The outputs of both compliance runs were compared to see if the missing data would have adversely affected the results. Both of these results provided a percentage compliance of each building in the envelope and lighting categories, showing by how large a percentage each building either met or fell short of the ASHRAE/IESNA Standard 90.1-1999 energy code. The results of the compliance runs showed that 57.7 % of the buildings met or exceeded envelope requirements with defaults and that 68 % met or exceeded envelope requirements with the actual data. Also, 53.6 % of the buildings met or surpassed the lighting requirements

  9. Base level Investigation in various buildings and corresponding effective factors

    Directory of Open Access Journals (Sweden)

    Mohsen Tehranizadeh

    2017-07-01

    Full Text Available Base level is one of the important parameters in determining the seismic force and preliminary design of structural sections. Base level, According to 2800 seismic regulations, in cases which the basement perimeter is executed with reinforced concrete walls integrated by structure, in addition with surrounding dense soil; set top of basement walls. The critical issue involved in determining base level is horizontal motion of the land. Usually horizontal movement of the Earth is transferred by shear and friction between the edges of the basement walls and foundation, also this process is completed by soil friction between underside of slabs and shallow. Different conditions such as non-same elevated foundations, soil type around building, soil-structure interaction and type of foundation are impressive on location of base level. Other factors including retaining wall openings in basement, basement floors and soil characteristics around the base structures affect base level coordination. As regards there is cleared definition for base level in different regulation all around the world, sometimes engineers cannot comprehend main purpose correctly, or concepts occasionally are interpreted inaccurately. When structure conditions little different from what normally there is, for example, buildings on slope, or structures on deep foundation such as piles, often experts are conflicted by finding location of base level in this status. In this paper investigations about base level in the past years expressed and studied, also, important issues around them are discussed.

  10. A perspective study on green cleaning for Malaysian public hospital

    Science.gov (United States)

    Ramli, N. A.; Zawawi, E. M.; Arif, N. R. M.; Mahbob, N. S.; Sulaiman, Z.; Zainol, N. N.

    2018-02-01

    Cleaning being a major contributor to the operations and maintenance expenditure and also Indoor Environmental Quality (IEQ) issues. Improper and ineffective cleaning can harm the environment and poses greatest risk to health. The use of traditional cleaning products presents a variety of human health and ecological concerns; and may contribute to poor IEQ. As an effort to reduce the issue of operations and maintenance costs and IEQ issues in a building, it is important to establish a green cleaning programme to ensure that the buildings are cleaned in a green way. Numbers of scholars has pointed out the factors which had prevented the green cleaning implementation in hospital buildings. Nonetheless, the significance of these factors has yet to be practically explored in the Malaysian context. Hence, the aim of the paper is to identify the most critical factor that prevents the implementation of green cleaning in Malaysian hospital building. A questionnaire survey and personal communication (i.e. interview) was conducted which involved two groups of respondents. They are the hospital maintenance staff (Cleansing Service Department) and cleaning contractors. Frequency and criticality index calculations have been used to rank these factors according to the level of importance. The result showed that an “unclear components and requirements of green cleaning” indicated as the most critical factor that prevent the implementation of green cleaning in Malaysian hospital building. In the concern for a successful implementation of green cleaning, it is hope that the findings of these studies can be enlightenment to the cleaning contractors as well as the hospital maintenance management team in Malaysia.

  11. Healthcare Building Sustainability Assessment tool - Sustainable Effective Design criteria in the Portuguese context

    International Nuclear Information System (INIS)

    Castro, Maria de Fátima; Mateus, Ricardo; Bragança, Luís

    2017-01-01

    Tools and methods to improve current practices and quality in the healthcare building sector are necessary to support decision-making at different building life cycle phases. Furthermore, Healthcare Building Sustainability Assessment (HBSA) Methods are based on criteria organised into different levels, such as categories and indicators. These criteria highlight aspects of significant importance when designing and operating a sustainable healthcare building. To bring more objectivity to the sustainability assessments, the standardisation bodies (CEN and ISO) proposed core indicators that should be used in the evaluation of the environmental, societal and economic performances of buildings. Nevertheless, relying on state of the art analysis, it is possible to conclude that there are aspects of major importance for the operation of healthcare buildings that are not considered in the HBSA methods. Thus, the aim of this paper is to discuss the context of sustainability assessment methods in the field of healthcare buildings and to present a proposal for the incorporation of Sustainable-Effective Design (SED) criteria in a new HBSA method. The used research method is innovative since in the development of the list of sustainability criteria it considers the opinion of main healthcare buildings' stakeholders, the existing healthcare assessment methods and the ISO and CEN standardisation works in the field of the methods to assess the sustainability of construction works. As a result, the proposed method is composed of fifty-two sustainability indicators that cover the different dimensions of the sustainability concept to support decision making during the design of a new or retrofitted healthcare building in urban areas. - Highlights: •A new system to assess the sustainability of healthcare buildings is presented. •We propose a method to develop the list of sustainability indicators for hospitals. •We propose a new concept – Sustainable-Effective Design (SED

  12. Clean Energy Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    For the past several years, the IEA and others have been calling for a clean energy revolution to achieve global energy security, economic growth and climate change goals. This report analyses for the first time progress in global clean energy technology deployment against the pathways that are needed to achieve these goals. It provides an overview of technology deployment status, key policy developments and public spending on RDD&D of clean energy technologies.

  13. Building Effective Pipelines to Increase Diversity in the Geosciences

    Science.gov (United States)

    Snow, E.; Robinson, C. R.; Neal-Mujahid, R.

    2017-12-01

    The U.S. Geological Survey (USGS) recognizes and understands the importance of a diverse workforce in advancing our science. Valuing Differences is one of the guiding principles of the USGS, and is the critical basis of the collaboration among the Youth and Education in Science (YES) program in the USGS Office of Science, Quality, and Integrity (OSQI), the Office of Diversity and Equal Opportunity (ODEO), and USGS science centers to build pipeline programs targeting diverse young scientists. Pipeline programs are robust, sustained relationships between two entities that provide a pathway from one to the other, in this case, from minority serving institutions to the USGS. The USGS has benefited from pipeline programs for many years. Our longest running program, with University of Puerto Rico Mayaguez (UPR), is a targeted outreach and internship program that has been managed by USGS scientists in Florida since the mid-1980's Originally begun as the Minority Participation in the Earth Sciences (MPES ) Program, it has evolved over the years, and in its several forms has brought dozens of interns to the USGS. Based in part on that success, in 2006 USGS scientists in Woods Hole MA worked with their Florida counterparts to build a pipeline program with City College of New York (CCNY). In this program, USGS scientists visit CCNY monthly, giving a symposium and meeting with students and faculty. The talks are so successful that the college created a course around them. In 2017, the CCNY and UPR programs brought 12 students to the USGS for summer internships. The CCNY model has been so successful that USGS is exploring creating similar pipeline programs. The YES office is coordinating with ODEO and USGS science centers to identify partner universities and build relationships that will lead to robust partnership where USGS scientists will visit regularly to engage with faculty and students and recruit students for USGS internships. The ideal partner universities will have a

  14. Soil Structure Interaction Effect on High Rise and Low Rise Buildings

    OpenAIRE

    Divya Pathak; PAresh H. SHAH

    2000-01-01

    Effect of supporting soil on the response of structure has been analyzed in the present study. A low rise (G+ 5 storey) and a high rise (G+12 storey) building has been taken for the analysis. For both type of buildings, the response of building with and without consideration of soil structure interaction effect has been compared.Without interaction case is the case in which ends of the structure are assumed to be fixed while in interaction case, structure is assumed to be...

  15. Effects of building roof greening on air quality in street canyons

    Science.gov (United States)

    Baik, Jong-Jin; Kwak, Kyung-Hwan; Park, Seung-Bu; Ryu, Young-Hee

    2012-12-01

    Building roof greening is a successful strategy for improving urban thermal environment. It is of theoretical interest and practical importance to study the effects of building roof greening on urban air quality in a systematic and quantitative way. In this study, we examine the effects of building roof greening on air quality in street canyons using a computational fluid dynamics (CFD) model that includes the thermodynamic energy equation and the transport equation of passive, non-reactive pollutants. For simplicity, building roof greening is represented by specified cooling. Results for a simple building configuration with a street canyon aspect ratio of one show that the cool air produced due to building roof greening flows into the street canyon, giving rise to strengthened street canyon flow. The strengthened street canyon flow enhances pollutant dispersion near the road, which decreases pollutant concentration there. Thus, building roof greening improves air quality near the road. The degree of air quality improvement near the road increases as the cooling intensity increases. In the middle region of the street canyon, the air quality can worsen when the cooling intensity is not too strong. Results for a real urban morphology also show that building roof greening improves air quality near roads. The degree of air quality improvement near roads due to building roof greening depends on the ambient wind direction. These findings provide a theoretical foundation for constructing green roofs for the purpose of improving air quality near roads or at a pedestrian level as well as urban thermal environment. Further studies using a CFD model coupled with a photochemistry model and a surface energy balance model are required to evaluate the effects of building roof greening on air quality in street canyons in a more realistic framework.

  16. Portable sandblaster cleans small areas

    Science.gov (United States)

    Severin, H. J.

    1966-01-01

    Portable sandblasting unit rapidly and effectively cleans localized areas on a metal surface. The unit incorporates a bellows enclosure, masking plate, sand container, and used sand accummulator connected to a vacuum system. The bellows is equipped with an inspection window and light for observation of the sanding operation.

  17. Meeting the clean air demand

    International Nuclear Information System (INIS)

    Hocker, C.

    1991-01-01

    This article addresses the impacts to the emissions control industry and the future of small independent projects of the Clean Air Act. Topics discussed include technological and market niche of pollution control companies, risk reduction by owning and operating the emission control portion of the plant as a separate entity, the diversity of technologies, and legislative effects

  18. Likely-clean concrete disposition at Chalk River Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Betts, J.A. [Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    2011-07-01

    The vast majority of wastes produced at nuclear licensed sites are no different from wastes produced from other traditional industrial activities. Radiation and contamination control practices ensure that the small amounts of waste materials that contain a radiation and or contamination hazard are segregated and managed appropriately according to the level of hazard. Part of the segregation process involves additional clearance checks of wastes generated in areas where the potential to become radioactively contaminated exists, but is very small and contamination control practices are such that the wastes are believed to be 'likely-clean'. This important clearance step helps to ensure that radioactive contamination is not inadvertently released during disposition of inactive waste materials. Clearance methods for bagged likely-clean wastes (i.e. small volumes of low density wastes) or discreet non-bagged items are well advanced. Clearance of bagged likely-clean wastes involves measuring small volumes of bagged material within purpose built highly sensitive bag monitors. For non-bagged items the outer surfaces are scanned to check for surface contamination using traditional hand-held contamination instrumentation. For certain very bulky and porous materials (such as waste concrete), these traditional clearance methods are impractical or not fully effective. As a somewhat porous (and dense) material, surface scanning cannot always be demonstrated to be conclusive. In order to effectively disposition likely-clean concrete, both the method of clearance (i.e. conversion from likely-clean to clean) and method of disposition have to be considered. Likely-clean concrete wastes have been produced at Chalk River Laboratories (CRL) from demolitions of buildings and structures, as well as small amounts from site maintenance activities. A final disposition method for this material that includes the secondary clearance check that changes the classification of this

  19. Likely-clean concrete disposition at Chalk River Laboratories

    International Nuclear Information System (INIS)

    Betts, J.A.

    2011-01-01

    The vast majority of wastes produced at nuclear licensed sites are no different from wastes produced from other traditional industrial activities. Radiation and contamination control practices ensure that the small amounts of waste materials that contain a radiation and or contamination hazard are segregated and managed appropriately according to the level of hazard. Part of the segregation process involves additional clearance checks of wastes generated in areas where the potential to become radioactively contaminated exists, but is very small and contamination control practices are such that the wastes are believed to be 'likely-clean'. This important clearance step helps to ensure that radioactive contamination is not inadvertently released during disposition of inactive waste materials. Clearance methods for bagged likely-clean wastes (i.e. small volumes of low density wastes) or discreet non-bagged items are well advanced. Clearance of bagged likely-clean wastes involves measuring small volumes of bagged material within purpose built highly sensitive bag monitors. For non-bagged items the outer surfaces are scanned to check for surface contamination using traditional hand-held contamination instrumentation. For certain very bulky and porous materials (such as waste concrete), these traditional clearance methods are impractical or not fully effective. As a somewhat porous (and dense) material, surface scanning cannot always be demonstrated to be conclusive. In order to effectively disposition likely-clean concrete, both the method of clearance (i.e. conversion from likely-clean to clean) and method of disposition have to be considered. Likely-clean concrete wastes have been produced at Chalk River Laboratories (CRL) from demolitions of buildings and structures, as well as small amounts from site maintenance activities. A final disposition method for this material that includes the secondary clearance check that changes the classification of this

  20. Social and ecological effects of biomass utilization and the willingness to use clean energy in the eastern Qinghai–Tibet plateau

    International Nuclear Information System (INIS)

    Ping, Xiaoge; Jiang, Zhigang; Li, Chunwang

    2012-01-01

    We conducted surveys in 19 villages on the Qinghai–Tibet plateau to explore the social and ecological effects of household biomass utilization and local people's willingness to use clean energy. Results showed that biomass was commonly used on this plateau. Dung combustion generated heavy indoor smoke in pastoral regions. Women were main dung collectors, who spent 1.8 h per day on dung collection. Crop residues and firewood were mainly collected by adults. Most respondents would like to rest while few chose to entertain or study when the time for biomass collection was saved. Tree numbers decreased in agricultural regions and grasslands deteriorated in pastoral regions recently according to most respondents. There were significant differences in the willingness to use modern energy, but no significant difference in the willingness to use clean energy among households from regions with different livelihoods. Almost all the respondents would like to use clean energy when there was no economic constraint but paid no attention to the environmental impact of fuel choice. Livelihood and region were main determinants in modern energy utilization, and energy price was the main determinant of fuel choice. Future energy development should focus on finding new ways to utilize biomass and exploring renewable energy. - Highlight: ► Rural household survey is done in 19 villages on the Qinghai–Tibet plateau. ► Biomass collection and utilization cost time and are bad for health and ecosystem. ► Price is the main determinant of fuel choice. ► Most households are willing to use clean energy but pay no attention to the environment. ► Future development should focus on finding new ways to utilize biomass and exploring renewable energy.

  1. Flue gas cleaning chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Gutberlet, H [VEBA Kraftwerke Ruhr AG, Gelsenkirchen (Germany)

    1996-12-01

    The introduction of modern flue gas cleaning technology into fossil-fueled power stations has repeatedly confronted the power station chemists with new and interesting problems over the last 15 - 20 years. Both flue gas desulphurization by lime washing and catalytic removal of nitrogen oxides are based on simple basic chemical reactions. Owing to the use of readily available starting materials, the production of safe, useful end products and, last but not least, the possibility of implementing all this on an industrial scale by means of efficient process engineering, limestone desulphurization and catalytic removal of nitrogen oxides dominate the world market and, little by little, are becoming still more widespread. The origin and thus the quality of fuels and starting materials, the firing method, the mode of operation and engineering peculiarities in each plant interact in a complex manner. Simple cause/effect relationships are frequently incapable of explaining phenomena; thinking in complex interrelationships is needed. (EG)

  2. Monitoring the Energy-Use Effects of Cool Roofs on California Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Konopaki, Steve; Rainer, Leo

    2004-07-01

    Solar-reflective roofs stay cooler in the sun than solar-absorptive roofs. Such ''cool'' roofs achieve lower surface temperatures that reduce heat conduction into the building and the building's cooling load. The California Energy Commission has funded research in which Lawrence Berkeley National Laboratory (LBNL) has measured the electricity use and peak demand in commercial buildings to document savings from implementing the Commission's Cool Roofs program. The study seeks to determine the savings achieved by cool roofs by monitoring the energy use of a carefully selected assortment of buildings participating in the Cool Roofs program. Measurements were needed because the peak savings resulting from the application of cool roofs on different types of buildings in the diverse California climate zones have not been well characterized to date. Only a few occupancy categories (e.g., office and retail buildings) have been monitored before this, and those were done under a limited number of climatic conditions. To help rectify this situation, LBNL was tasked to select the buildings to be monitored, measure roof performance before and after replacing a hot roof by a cool roof, and document both energy and peak demand savings resulting from installation of cool roofs. We monitored the effects of cool roofs on energy use and environmental parameters in six California buildings at three different sites: a retail store in Sacramento; an elementary school in San Marcos (near San Diego); and a 4-building cold storage facility in Reedley (near Fresno). The latter included a cold storage building, a conditioning and fruit-palletizing area, a conditioned packing area, and two unconditioned packing areas (counted as one building).

  3. Wet-cleaning of MgO(001): Modification of surface chemistry and effects on thin film growth investigated by x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectroscopy

    OpenAIRE

    Le Febvrier, Arnaud; Jensen, Jens; Eklund, Per

    2017-01-01

    The effect of the wet-cleaning process using solvents and detergent on the surface chemistry of MgO(001) substrate for film deposition was investigated. Six different wet-cleaning processes using solvent and detergent were compared. The effect on film growth was studied by the example system ScN. The surface chemistry of the cleaned surface was studied by x-ray photoelectron spectroscopy and the film/substrate interface after film growth was investigated by time-of-flight secondary ion mass s...

  4. A Building Energy Efficiency Optimization Method by Evaluating the Effective Thermal Zones Occupancy

    Directory of Open Access Journals (Sweden)

    Franco Cotana

    2012-12-01

    Full Text Available Building energy efficiency is strongly linked to the operations and control systems, together with the integrated performance of passive and active systems. In new high quality buildings in particular, where these two latter aspects have been already implemented at the design stage, users’ perspective, obtained through post-occupancy assessment, has to be considered to reduce whole energy requirement during service life. This research presents an innovative and low-cost methodology to reduce buildings’ energy requirements through post-occupancy assessment and optimization of energy operations using effective users’ attitudes and requirements as feedback. As a meaningful example, the proposed method is applied to a multipurpose building located in New York City, NY, USA, where real occupancy conditions are assessed. The effectiveness of the method is tested through dynamic simulations using a numerical model of the case study, calibrated through real monitoring data collected on the building. Results show that, for the chosen case study, the method provides optimized building energy operations which allow a reduction of primary energy requirements for HVAC, lighting, room-electricity, and auxiliary supply by about 21%. This paper shows that the proposed strategy represents an effective way to reduce buildings’ energy waste, in particular in those complex and high-efficiency buildings that are not performing as well as expected during the concept-design-commissioning stage, in particular due to the lack of feedback after the building handover.

  5. How clean is clean?---How clean is needed?

    International Nuclear Information System (INIS)

    Hays, A.K.

    1991-01-01

    This paper will provide an overview of cleaning qualifications used in a variety of industries: from small-scale manufacturer's of precision-machined products to large-scale manufacturer's of electronics (printed wiring boards and surface mount technology) and microelectronics. Cleanliness testing techniques used in the production of precision-machined products, will be described. The on-going DOD program to obtain high-reliability electronics, through the use of military specifications for cleaning and cleanliness levels, will be reviewed. In addition, the continually changing cleanroom/materials standards of the microelectronics industry will be discussed. Finally, we will speculate on the role that new and improved analytical techniques and sensor technologies will play in the factories of the future. 4 refs., 1 tab

  6. Impact of coupled heat and moisture transfer effects on buildings energy consuption

    Directory of Open Access Journals (Sweden)

    Ferroukhi Mohammed Yacine

    2017-01-01

    Full Text Available Coupled heat, air, and moisture transfers through building envelope have an important effect on prediction of building energy requirements. Several works were conducted in order to integrate hygrothermal transfers in dynamic buildings simulations codes. However, the incorporation of multidirectional hygrothermal transfer analysis in the envelope into building simulation tools is rarely considered. In this work, coupled heat, air, and moisture (HAM transfer model in multilayer walls was established. Thereafter, the HAM model is coupled dynamically to a building behavior code (BES.The coupling concerns a co-simulation between COMSOL Multiphysics and TRNSYS software. Afterward, the HAM-BES co-simulation accuracy was verified. Then, HAM-BES co-simulation platform was applied to a case study with various types of climates (temperate, hot and humid, cold and humid. Three simulations cases were carried out. The first simulation case consists of the TRNSYS model without HAM transfer model. The second simulation case, 1-D HAM model for the envelope was integrated in TRNSYS code. For the third one, 1-D HAM model for the wall and 2-D HAM model for thermal bridges were coupled to the thermal building model of TRNSYS. Analysis of the results confirms the significant impact of 2-D envelope hygrothermal transfers on the indoor thermal and moisture behavior of building as well as on the energy building assessment. These conclusions are shown for different studied climates.

  7. Effect of phase change material on the heat transfer rate of different building materials

    Science.gov (United States)

    Hasan, Mushfiq; Alam, Shahnur; Ahmed, Dewan Hasan

    2017-12-01

    Phase change material (PCM) is widely known as latent heat storage. A comprehensive study is carried out to investigate the effect of PCM on heat transfer rate of building materials. Paraffin is used as PCM along with different conventional building materials to investigate the heat transfer rate from the heated region to the cold region. PCM is placed along with the three different types of building materials like plaster which is well know building material in urban areas and wood and straw which are commonly used in rural areas for roofing as well as wall panel material and investigated the heat transfer rate. An experimental setup was constructed with number of rectangular shape aluminum detachable casing (as cavity) and placed side by side. Series of rectangular cavity filled with convent ional building materials and PCM and these were placed in between two chambers filled with water at different temperature. Building materials and PCM were placed in different cavities with different combinations and investigated the heat transfer rate. The results show that using the PCM along with other building materials can be used to maintain lower temperature at the inner wall and chamber of the cold region. Moreover, the placement or orientation of the building materials and PCM make significant contribution to heat transfer rate from the heated zone to the cold zone.

  8. Carbon dioxide cleaning pilot project

    International Nuclear Information System (INIS)

    Knight, L.; Blackman, T.E.

    1994-01-01

    In 1989, radioactive-contaminated metal at the Rocky Flats Plant (RFP) was cleaned using a solvent paint stripper (Methylene chloride). One-third of the radioactive material was able to be recycled; two-thirds went to the scrap pile as low-level mixed waste. In addition, waste solvent solutions also required disposal. Not only was this an inefficient process, it was later prohibited by the Resource Conservation and Recovery Act (RCRA), 40 CFR 268. A better way of doing business was needed. In the search for a solution to this situation, it was decided to study the advantages of using a new technology - pelletized carbon dioxide cleaning. A proof of principle demonstration occurred in December 1990 to test whether such a system could clean radioactive-contaminated metal. The proof of principle demonstration was expanded in June 1992 with a pilot project. The purpose of the pilot project was three fold: (1) to clean metal so that it can satisfy free release criteria for residual radioactive contamination at the Rocky Flats Plant (RFP); (2) to compare two different carbon dioxide cleaning systems; and (3) to determine the cost-effectiveness of decontamination process in a production situation and compare the cost of shipping the metal off site for waste disposal. The pilot project was completed in August 1993. The results of the pilot project were: (1) 90% of those items which were decontaminated, successfully met the free release criteria , (2) the Alpheus Model 250 was selected to be used on plantsite and (3) the break even cost of decontaminating the metal vs shipping the contaminated material offsite for disposal was a cleaning rate of 90 pounds per hour, which was easily achieved

  9. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...... supply rate with CAHP air purification of recirculated air with three different outdoor air supply rates without recirculation or air cleaning. Sensory assessments of perceived air quality and chemical measurements of TVOC concentration were used to evaluate the air-cleaning performance of the CAHP....... The results of the experiment showed that the operation of the CAHP significantly improved the perceived air quality in a room polluted by both human bio-effluents and building materials. At the outdoor airflow rate of 2 L/s per person, the indoor air quality with CAHP was equivalent to what was achieved...

  10. Guidelines for Building Science Education

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, Cheryn E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rashkin, Samuel [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huelman, Pat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-01

    The U.S. Department of Energy’s (DOE) residential research and demonstration program, Building America, has triumphed through 20 years of innovation. Partnering with researchers, builders, remodelers, and manufacturers to develop innovative processes like advanced framing and ventilation standards, Building America has proven an energy efficient design can be more cost effective, healthy, and durable than a standard house. As Building America partners continue to achieve their stretch goals, they have found that the barrier to true market transformation for high performance homes is the limited knowledge-base of the professionals working in the building industry. With dozens of professionals taking part in the design and execution of building and selling homes, each person should have basic building science knowledge relevant to their role, and an understanding of how various home components interface with each other. Instead, our industry typically experiences a fragmented approach to home building and design. After obtaining important input from stakeholders at the Building Science Education Kick-Off Meeting, DOE created a building science education strategy addressing education issues preventing the widespread adoption of high performance homes. This strategy targets the next generation and provides valuable guidance for the current workforce. The initiative includes: • Race to Zero Student Design Competition: Engages universities and provides students who will be the next generation of architects, engineers, construction managers and entrepreneurs with the necessary skills and experience they need to begin careers in clean energy and generate creative solutions to real world problems. • Building Science to Sales Translator: Simplifies building science into compelling sales language and tools to sell high performance homes to their customers. • Building Science Education Guidance: Brings together industry and academia to solve problems related to

  11. Carbon pricing comes clean

    International Nuclear Information System (INIS)

    De Wit, Elisa

    2011-01-01

    Together with the Clean Energy Bill, the implications of the Australian Federal Government's climate change legislative package are far reaching. Norton Rose gives business a heads-up in this breakdown of the draft legislation underpinning the carbon pricing and clean energy scheme. It is a summary of Norton Rose's full analysis.

  12. Mechanical cleaning of graphene

    NARCIS (Netherlands)

    Goossens, A.M.; Calado, V.E.; Barreiro, A.; Watanabe, K.; Taniguchi, T.; Vandersypen, L.M.K.

    2012-01-01

    Contamination of graphene due to residues from nanofabrication often introduces background doping and reduces electron mobility. For samples of high electronic quality, post-lithography cleaning treatments are therefore needed. We report that mechanical cleaning based on contact mode atomic force

  13. Green Cleaning Label Power

    Science.gov (United States)

    Balek, Bill

    2012-01-01

    Green cleaning plays a significant and supportive role in helping education institutions meet their sustainability goals. However, identifying cleaning products, supplies and equipment that truly are environmentally preferable can be daunting. The marketplace is inundated with products and services purporting to be "green" or environmentally…

  14. Criteria of the effectiveness of a liaison center for the machine building industry

    International Nuclear Information System (INIS)

    Hofer, P.; Wolff, H.; Franzen, D.

    1977-06-01

    The study aimed at working out a catalogue of criteria for the effective work of a liaison center for the machine building industry within the planned system of information and documentation of the German Government. By selecting this objective, the investigation methodically demanded a continuous change between theoretical analysis (study of literature, analytical deduction of the framework for a user-oriented information system) and empirical observation of information behaviour in the machine building industry (personal interviews with enterprises and important information sources for the machine building industries). An information system keyed to the information needs of the machine building industry must cover three main phases: Collection and documentation of information, selecting and procuring the needed information as well as encouraging and consulting the clients on the use of information. These different tasks complement one another, they correspond to different functions within enterprises: management, staff, and information function. Central point of a liaison center must be the task of selecting the required information (making information available, selling good information, analysing the information needs of clients), completed by fields of activity in documenting information (specifically for the machine building industry) and consulting clients on the use of information (agency for contacts, drawing the clients' attention to the complexity of machine building problems). A concrete catalogue of criteria for an effective conception of a liaison center for the machine building industry has been worked out. (orig.) [de

  15. Criteria of the effectiveness of a liaison center for the machine building industry

    International Nuclear Information System (INIS)

    Hofer, P.; Wolff, H.; Franzen, D.; Schlichting, J.; Weidig, I.

    1978-04-01

    The study aimed at working out a catalogue of criteria for the effective work of a liaison center for the machine building industry within the planned system of information and documentation of the German Government. By selecting this objective, the investigation methodically demanded a continuous change between theoretical analysis (study of literature, analytical deduction of the framework for a user-oriented information system) and empirical observation of information behaviour in the machine building industry (personal interviews with enterprises and important information sources for the machine building industries). An information system keyed to the information needs of the machine building industry must cover three main phases: Collection and documentation of information, selecting and procuring the needed information as well as encouraging and consulting the clients on the use of information. These different tasks complement one another, they correspond to different functions within enterprises: management, staff, and information function. Central point of a liaison center must be the task of selecting the required information (making information available, selling good information, analysing the information needs of clients), completed by fields of activity in documenting information (specifically for the machine building industry) and consulting clients on the use of information (agency for contacts, drawing the client's attention to the complexity of machine building problems). A concrete catalogue of criteria for an effective conception of a liaison center for the machine building industry has been worked out. (orig.) [de

  16. Assessing the Multiple Benefits of Clean Energy Full Report

    Science.gov (United States)

    Guidance for state energy, environmental, and economic policy makers to identify and quantify the many benefits of clean energy to support the development and implementation of cost-effective clean energy initiatives.

  17. Decomposition of no-clean solder flux systems and their effects on the corrosion reliability of electronics

    DEFF Research Database (Denmark)

    Conseil, Helene; Verdingovas, Vadimas; Jellesen, Morten Stendahl

    2016-01-01

    No-clean flux systems are used today for the soldering of electronic printed circuit board assemblies assuming that all the aggressive substances of the flux will vanish during the soldering process i.e. evaporate, decompose or being enclosed safely in the residues. However this is not true in most...... that the fluxes do not decompose fully within the temperature regime of the soldering process, leaving behind significant level of weak organic acid residues. The residue depending on the type and amount can be can be very aggressive towards the corrosion on the printed circuit board assemblies. The glutaric acid...

  18. The regulation of hazardous air pollutants under the Clean Air Act Amendments of 1990: Effects on the Portland cement industry

    International Nuclear Information System (INIS)

    Mikols, E.H.; Gill, A.S.; Dougherty, A.

    1996-01-01

    Title III of the 1990 Clean Air Act Amendments (CAAA) addresses the control of hazardous air pollutants (HAPs) from major sources of air pollution in the US. In the CAAA, Congress defined 189 compounds as hazardous air pollutants in need of additional control by the Environmental Protection Agency (EPA). Congress directed EPA to identify the major source categories which emit HAPs and to prepare regulations that would reduce and control future HAP emissions. This paper outlines the activities undertaken by EPA to regulate HAP emissions from Portland cement plants and the program developed by the Portland cement manufacturing industry to cope with Title III

  19. Laser cleaning on Roman coins

    Science.gov (United States)

    Drakaki, E.; Karydas, A. G.; Klinkenberg, B.; Kokkoris, M.; Serafetinides, A. A.; Stavrou, E.; Vlastou, R.; Zarkadas, C.

    Ancient metal objects react with moisture and environmental chemicals to form various corrosion products. Because of the unique character and high value of such objects, any cleaning procedure should guarantee minimum destructiveness. The most common treatment used is mechanical stripping, in which it is difficult to avoid surface damage when employed. Lasers are currently being tested for a wide range of conservation applications. Since they are highly controllable and can be selectively applied, lasers can be used to achieve more effective and safer cleaning of archaeological artifacts and protect their surface details. The basic criterion that motivated us to use lasers to clean Roman coins was the requirement of pulsed emission, in order to minimize heat-induced damages. In fact, the laser interaction with the coins has to be short enough, to produce a fast removal of the encrustation, avoiding heat conduction into the substrate. The cleaning effects of three lasers operating at different wavelengths, namely a TEA CO2 laser emitting at 10.6 μm, an Er:YAG laser at 2.94 μm, and a 2ω-Nd:YAG laser at 532 nm have been compared on corroded Romans coins and various atomic and nuclear techniques have also been applied to evaluate the efficiency of the applied procedure.

  20. Cleaning metal filters by pulse-jet

    International Nuclear Information System (INIS)

    Pickard, P.; Perry, R.A.

    1986-01-01

    Cleanable metal filters have an established use in the Nuclear Industry. The filters that have been installed in the past have not proved to be sufficiently cleanable. A series of tests were undertaken to study the application of pulse-jet cleaning to metal fibre filter elements. The efficiency of dust removal was examined under various operating conditions. A very high degree of particulate removal was achieved, with a return to almost clean pressure drop. The effectiveness of cleaning was found to vary inversely with blowback pressure. The position of the blowback nozzle with respect to the filter element throat was also found to be important to cleaning efficiency. Under the test conditions the effect of re-entrainment when cleaning on line was found to be minimal. (author)

  1. Effect of nonlinearity of connecting dampers on vibration control of connected building structures

    Directory of Open Access Journals (Sweden)

    Masatoshi eKasagi

    2016-01-01

    Full Text Available The connection of two building structures with dampers is one of effective vibration control systems. In this vibration control system, both buildings have to possess different vibration properties in order to provide a higher vibration reduction performance. In addition to such condition of different vibration properties of both buildings, the connecting dampers also play an important role in the vibration control mechanism. In this paper, the effect of nonlinearity of connecting dampers on the vibration control of connected building structures is investigated in detail. A high-damping rubber damper and an oil damper with and without relief mechanism are treated. It is shown that, while the high-damping rubber damper is effective in a rather small deformation level, the linear oil damper is effective in a relatively large deformation level. It is further shown that, while the oil dampers reduce the response in the same phase as the case without dampers, the high-damping rubber dampers change the phase. The merit is that the high-damping rubber can reduce the damper deformation and keep the sufficient space between both buildings. This can mitigate the risk of building pounding.

  2. Effects of soil stiffness and embedment on reactor building response

    International Nuclear Information System (INIS)

    Michalopoulos, A.P.; Vardanega, C.; Cornaggia, L.

    1981-01-01

    A parametric study was made to assess the influence of soil conditions and foundation embedment depth on the floor response spectra for a reactor building. The analyses incorporated soft, medium and hard soils, and three different embedment depths, in a seismic environment described by a 0.36 g peak ground acceleration. The shear wave velocity profiles for the soft, medium and hard soil conditions, were assumed to increase in proportion to the square root of depth from their ground surface values of 300, 600 and 900 meters per second, respectively. Foundation embedment depths of zero, eight and fourteen meters were analyzed using elastic half-space theory, accounting for kinematic interaction. The variation of shear modulus with depth under earthquake excitation was determined using a deconvolution process. Horizontal and vertical synthetic time histories, matching the USNRC Regulatory Guide 1.60 design ground response spectra, were applied at the ground surface and then deconvolved to the foundation level to obtain the input for the soil-structure model. The mathematical model of the superstructure consisted of four lumped-mass close-coupled systems, representing containment shells and components, while the foundation mat was modeled as rigid. Lumped soil compliances (springs and dashpots) were used to represent the horizontal, vertical and rotational modes of vibration. The dynamic analyses were performed utilizing the computer code DAPSYS, and consisted of mode frequency analyses and modal superposition. Modal damping was computed as a weighted average of structural and soil (radiation and material) damping, using the strain energy stored in the respective components as the weighting factor and distinguishing the hysteric nature of the structural and soil material damping, and the viscous nature of the soil radiation damping. (orig./RW)

  3. The Effect of Mechanical Load on the Thermal Conductivity of Building Materials

    Directory of Open Access Journals (Sweden)

    J. Toman

    2000-01-01

    Full Text Available The effect of mechanical load on the thermal conductivity of building materials in the design of envelope parts of building structures is studied. A typical building material is chosen in the practical investigation of this effect, namely the cement mortar. It is concluded that in the range of hygroscopic moisture content, lower levels of mechanical load, typically up to 90 % of compressive strength (CS, are not dangerous from the point of view of worsening the designed thermal properties, but in the overhygroscopic region, the load as low as 57 % of CS may be dangerous. The higher levels of loading are found to be always significant because they lead to marked increase of thermal conductivity which is always a negative information for a building designer.

  4. A study on the effects of double skin facades on the energy management in buildings

    International Nuclear Information System (INIS)

    Chou, S.K.; Chua, K.J.; Ho, J.C.

    2009-01-01

    Double skin facades (DSF) are gaining popularity for their ability to reduce solar heat gain in buildings. However, research works on the impact of DSF on the energy management, aerophysics and air conditioning of buildings are still at their infancy. The concept of envelope thermal transfer value (ETTV) has been specifically applied to evaluate the solar radiation gain component through a DSF fenestration system. The aim of this paper is to study the effects of DSF on the solar heat gain, the ETTV and hence the energy management within buildings. A systematic methodology to investigate the effectiveness of DSF in reducing solar heat gain has been presented. Experimental works have been performed to obtain the solar heat gain coefficient (SHGC) values of a DSF fenestration system. These values are then applied to compare the ETTVs generated from a model building with different DSF configurations, namely, different wall-to-window ratios and varying shading coefficients.

  5. ''How clean is clean'' in the United States federal and Washington State cleanup regulations

    International Nuclear Information System (INIS)

    Landau, H.G.

    1993-01-01

    The enactment of legislation and promulgation of implementing regulations generally involves the resolution of conflicting goals. Defining ''How Clean is Clean?'' in federal and state cleanup laws, regulations, and policies is no exception. Answering the ''How Clean is Clean?'' question has resulted in the identification of some important and sometimes conflicting goals. Continuing resolution of the following conflicting goals is the key to effect cleanup of hazardous waste sites: Expediency vs. Fairness; Flexibility vs. Consistency; Risk Reduction vs. Risk Causation; and Permanence vs. Cost Effectiveness

  6. A metric for characterizing the effectiveness of thermal mass in building materials

    International Nuclear Information System (INIS)

    Talyor, Robert A.; Miner, Mark

    2014-01-01

    Highlights: • Proposes a metric for interior thermal mass materials (floors, walls, counters). • Simple, yet effective, metric composed of easily calculated ‘local’ and ‘global’ variables. • Like Energy Star, the proposed metric gives a single number to aid consumer choice. • The metric is calculated and compared for selected, readily available data. • Drywall, concrete flooring, and wood paneling are quite effective thermal mass. - Abstract: Building energy use represents approximately 25% of the average total global energy consumption (for both residential and commercial buildings). Heating, ventilation, and air conditioning (HVAC) – in most climates – embodies the single largest draw inside our buildings. In many countries around the world a concerted effort is being made towards retrofitting existing buildings to improve energy efficiency. Better windows, insulation, and ducting can make drastic differences in the energy consumption of a building HVAC system. Even with these improvements, HVAC systems are still required to compensate for daily and seasonal temperature swings of the surrounding environment. Thermal mass inside the thermal envelope can help to alleviate these swings. While it is possible to add specialty thermal mass products to buildings for this purpose, commercial uptake of these products is low. Common building interior building materials (e.g. flooring, walls, countertops) are often overlooked as thermal mass products, but herein we propose and analyze non-dimensional metrics for the ‘benefit’ of selected commonly available products. It was found that location-specific variables (climate, electricity price, material price, insolation) can have more than an order of magnitude influence in the calculated metrics for the same building material. Overall, this paper provides guidance on the most significant contributors to indoor thermal mass, and presents a builder- and consumer-friendly metric to inform decisions about

  7. Optimizing Local Plant Products in Building Construction:Effects of ...

    African Journals Online (AJOL)

    ... and on bamboo reinforced concrete beams reveal that indeed truss configuration has marked effect on the stiffness and ultimate strength of trusses, where vertically aligned members as found in queen-post and Howe trusses are seen to be more effective than inclined members in load transfer and ultimate resistance.

  8. The ORC method. Effective modelling of thermal performance of multilayer building components

    Energy Technology Data Exchange (ETDEWEB)

    Akander, Jan

    2000-02-01

    The ORC Method (Optimised RC-networks) provides a means of modelling one- or multidimensional heat transfer in building components, in this context within building simulation environments. The methodology is shown, primarily applied to heat transfer in multilayer building components. For multilayer building components, the analytical thermal performance is known, given layer thickness and material properties. The aim of the ORC Method is to optimise the values of the thermal resistances and heat capacities of an RC-model such as to give model performance a good agreement with the analytical performance, for a wide range of frequencies. The optimisation procedure is made in the frequency domain, where the over-all deviation between model and analytical frequency response, in terms of admittance and dynamic transmittance, is minimised. It is shown that ORC's are effective in terms of accuracy and computational time in comparison to finite difference models when used in building simulations, in this case with IDA/ICE. An ORC configuration of five mass nodes has been found to model building components in Nordic countries well, within the application of thermal comfort and energy requirement simulations. Simple RC-networks, such as the surface heat capacity and the simple R-C-configuration are not appropriate for detailed building simulation. However, these can be used as basis for defining the effective heat capacity of a building component. An approximate method is suggested on how to determine the effective heat capacity without the use of complex numbers. This entity can be calculated on basis of layer thickness and material properties with the help of two time constants. The approximate method can give inaccuracies corresponding to 20%. In-situ measurements have been carried out in an experimental building with the purpose of establishing the effective heat capacity of external building components that are subjected to normal thermal conditions. The auxiliary

  9. Rudimentary Cleaning Compared to Level 300A

    Science.gov (United States)

    Arpin, Christina Y. Pina; Stoltzfus, Joel

    2012-01-01

    A study was done to characterize the cleanliness level achievable when using a rudimentary cleaning process, and results were compared to JPR 5322.1G Level 300A. While it is not ideal to clean in a shop environment, some situations (e.g., field combat operations) require oxygen system hardware to be maintained and cleaned to prevent a fire hazard, even though it cannot be sent back to a precision cleaning facility. This study measured the effectiveness of basic shop cleaning. Initially, three items representing parts of an oxygen system were contaminated: a metal plate, valve body, and metal oxygen bottle. The contaminants chosen were those most likely to be introduced to the system during normal use: oil, lubricant, metal shavings/powder, sand, fingerprints, tape, lip balm, and hand lotion. The cleaning process used hot water, soap, various brushes, gaseous nitrogen, water nozzle, plastic trays, scouring pads, and a controlled shop environment. Test subjects were classified into three groups: technical professionals having an appreciation for oxygen hazards; professional precision cleaners; and a group with no previous professional knowledge of oxygen or precision cleaning. Three test subjects were in each group, and each was provided with standard cleaning equipment, a cleaning procedure, and one of each of the three test items to clean. The results indicated that the achievable cleanliness level was independent of the technical knowledge or proficiency of the personnel cleaning the items. Results also showed that achieving a Level 300 particle count was more difficult than achieving a Level A nonvolatile residue amount.

  10. The Effectiveness of Full Day School System for Students’ Character Building

    Science.gov (United States)

    Benawa, A.; Peter, R.; Makmun, S.

    2018-01-01

    The study aims to put forward that full day school which was delivered in Marsudirini Elementary School in Bogor is effective for students’ character building. The study focused on the implementation of full day school system. The qualitative-based research method applied in the study is characteristic evaluation involving non-participant observation, interview, and documentation analysis. The result of this study concludes that the full day school system is significantly effective in education system for elementary students’ character building. The full day school system embraced the entire relevant processes based on the character building standard. The synergy of comprehensive components in instructional process at full day school has influenced the building of the students’ character effectively and efficiently. The relationship emerged between instructional development process in full day school system and the character building of the students. By developing instructional process through systemic and systematic process in full day school system, the support of stakeholders (leaders, human resources, students, parents’ role) and other components (learning resources, facilities, budget) provides a potent and expeditious contribution for character building among the students eventually.

  11. pH and redox effects of building materials

    International Nuclear Information System (INIS)

    Van der Sloot, H.A.; Van Zomeren, A.; Meeussen, J.C.L.; De Nie, D.S.

    2007-11-01

    The application of relatively fine grained industrial slags as fill material in industrial terrains and parking lots has led to unacceptably elevated pH values and imposed reducing conditions in ground- and surface water. Based on the Dutch Building Materials Decree the materials applied were classified as category 1 materials (free use). There are no limits set to pH and redox in this regulation. In itself a lower or higher pH and a low redox potential are not necessarily critical. Only when the buffer capacity of the surroundings is exceeded, undesirable situations may develop. In this work, the release of alkaline and reducing substances has been studied to assess if regulatory controls are needed and how such controls could be implemented practically. Both pH and redox potential are unsuitable properties for this purpose as it is the buffer capacity of the releasing material and the buffer capacity of the receiving soil and water bodies that determine whether unacceptable conditions develop. As pH and redox are also affected by gas reactions (O2 and CO2), the evaluation becomes relatively complex. Using the chemical speciation-transport model ORCHESTRA, a scenario description has been developed to assess the release of alkaline and reducing species from slag by infiltration under unsaturated conditions. Proper acid neutralization and redox buffering data for the materials were determined. Based on the sophisticated model results, a simplified model description was applied to link observations to impact. Decision schemes for applications above groundwater and in surface water have been developed based on the buffer capacity and particle size distribution of the material to be used, the infiltration rate, the degree of exposure to O2 and CO2 from the atmosphere or from soil air and the dimensions of the application. This has led to a preliminary guidance on implementing rules for acceptance of materials in specific applications. The modeled release predictions

  12. Chapter 2: Assessing the Potential Energy Impacts of Clean Energy Initiatives

    Science.gov (United States)

    Chapter 2 of Assessing the Multiple Benefits of Clean Energy helps state energy, environmental, and economic policy makers identify and quantify the many benefits of clean energy to support the development and implementation of cost-effective clean energ

  13. Synergic effects of thermal mass and natural ventilation on the thermal behaviour of traditional massive buildings

    Science.gov (United States)

    Gagliano, A.; Nocera, F.; Patania, F.; Moschella, A.; Detommaso, M.; Evola, G.

    2016-05-01

    The energy policies about energy efficiency in buildings currently focus on new buildings and on existing buildings in case of energy retrofit. However, historic and heritage buildings, that are the trademark of numerous European cities, should also deserve attention; nevertheless, their energy efficiency is nowadays not deeply investigated. In this context, this study evaluates the thermal performance of a traditional massive building situated in a Mediterranean city. Dynamic numerical simulations were carried out on a yearly basis through the software DesignBuilder, both in free-running conditions and in the presence of an air-conditioning (AC) system. The results highlight that the massive envelope of traditional residential buildings helps in maintaining small fluctuations of the indoor temperature, thus limiting the need for AC in the mid-season and in summer. This feature is highly emphasised by exploiting natural ventilation at night, which allows reducing the building energy demand for cooling by about 30%.The research also indicates that, for Mediterranean climate, the increase in thermal insulation does not always induce positive effects on the thermal performance in summer, and that it might even produce an increase in the heat loads due to the transmission through the envelope.

  14. Building Effective Water Governance in the Asian Highlands | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    This project seeks to facilitate effective water resource management in the Asian Highlands by integrating climate ... Journal articles ... Adaptation strategies for two Colombian cities were discussed at ADAPTO's second international workshop.

  15. The Connect Effect Building Strong Personal, Professional, and Virtual Networks

    CERN Document Server

    Dulworth, Michael

    2008-01-01

    Entrepreneur and executive development expert Mike Dulworth's THE CONNECT EFFECT provides readers with a simple framework and practical tools for developing that crucial competitive advantage: a high-quality personal, professional/organizational and virtual network.

  16. Clean coal technologies

    International Nuclear Information System (INIS)

    Aslanyan, G.S.

    1993-01-01

    According to the World Energy Council (WEC), at the beginning of the next century three main energy sources - coal, nuclear power and oil will have equal share in the world's total energy supply. This forecast is also valid for the USSR which possesses more than 40% of the world's coal resources and continuously increases its coal production (more than 700 million tons of coal are processed annually in the USSR). The stringent environmental regulations, coupled with the tendency to increase the use of coal are the reasons for developing different concepts for clean coal utilization. In this paper, the potential efficiency and environmental performance of different clean coal production cycles are considered, including technologies for coal clean-up at the pre-combustion stage, advanced clean combustion methods and flue gas cleaning systems. Integrated systems, such as combined gas-steam cycle and the pressurized fluidized bed boiler combined cycle, are also discussed. The Soviet National R and D program is studying new methods for coal utilization with high environmental performance. In this context, some basic research activities in the field of clean coal technology in the USSR are considered. Development of an efficient vortex combustor, a pressurized fluidized bed gasifier, advanced gas cleaning methods based on E-beam irradiation and plasma discharge, as well as new catalytic system, are are presented. In addition, implementation of technological innovations for retrofitting and re powering of existing power plants is discussed. (author)

  17. Decontamination of polypropylene fabrics by dry cleaning

    International Nuclear Information System (INIS)

    Severa, J.; Knajfl, J.

    1983-01-01

    Polypropylene fabrics can efficiently be decontaminated by dry cleaning in benzine or perchloroethylene, this also in case the fabric was greased in addition to radioactive contamination. For heavily soiled fabric, it is advantageous to first dry clean it and then wash it. The positive effect was confirmed of intensifiers on the cleaning process, especially of benzine soap. In practice, its concentration should be selected within 1 and 10 g.dm - 3 . Decontamination by dry cleaning and subsequent washing is advantageous in that that the resulting activity of waste water from the laundry is low. Radioactive wastes from the dry cleaning process have a low weight and can be handled as solid waste. (M.D.)

  18. Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

    Directory of Open Access Journals (Sweden)

    Qiang Xu

    2016-02-01

    Full Text Available The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH and finite element method (FEM coupling method is used to numerically simulate the fluid and structure interaction (FSI between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

  19. Cleaning of Sodium in the Cold Trap

    International Nuclear Information System (INIS)

    Kim, Byung Ho; Jeong, Ji Young; Kim, Jong Man; Choi, Byung Hae; Nam, Ho Yun

    2005-01-01

    The purpose of a cleaning process is to remove the residual sodium adhering to the component walls once it has been properly drained. It is necessary to clean and decontaminate a component, especially the large components of the primary coolant system; such as the intermediate heat exchangers and the primary pump. Improper and inadequate cleaning has in a number of cases resulted in problems in the storage, handling, and reuse of components. Several types of failures due to improper cleaning procedures have been defined in the past. Inadequate and incomplete removal of sodium results in residues which may contain metallic sodium and alkaline compounds such as sodium hydroxide, sodium oxide, sodium carbonate, and various types of alcoholates. Reinsertion of components containing these compounds into a high-temperature sodium system can result in either the intergranular penetration characteristic of a high- oxygen sodium or an accelerated corrosion due to oxygen. The methods used for cleaning sodium equipment depend on the condition and types of equipment to be cleaned and whether the equipment is to be reused. Cleaning methods are needed that will avoid a deleterious local overheating, material surface degradation or deposits, chemical, physical, or mechanical damage, and external effects. This paper discusses a steam-nitrogen gas cleaning method for the routine applications that permits the reuse of the cold trap in sodium

  20. Should you get your heating ducts cleaned?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Canada Mortgage and Housing Corporation conducted research into duct cleaning during which time several houses were tested for hot air furnace duct performance before and after cleaning. Duct cleaning is a major industry which claims that cleaning of ducts will provide you with better indoor air quality, reduce household molds and allergens, get rid of house dust, result in more airflow and better delivery of warm air and reduce energy costs. This report does not substantiate those claims. Researchers found little or no discernible differences in the concentrations of house airborne particles or in duct airflows due to duct cleaning. This is because ducts are metal passages that cannot create dust. Most household dusts come from outdoors that has been tracked in or blows through windows and other openings. While duct cleaning may be justifiable personally, it does not change the quality of the air you breathe, nor will it significantly affect airflow or heating costs. Some filters effectively clean the air in the ducts but they do not create a dust-free environment because of the above-mentioned dust sources. The only time that duct cleaning may make sense is if you have water in your ducts that can result in mold growth, if you are moving into a newly constructed house to remove drywall dust, if your are having trouble with furnace airflow, or if you see an accumulation of debris in the return air ducts. It was emphasized that broadcast spraying of biocides within the duct system should not be performed.

  1. Controlling the clean room atmosphere

    International Nuclear Information System (INIS)

    Meeks, R.F.

    1979-01-01

    Several types of clean rooms are commonly in use. They include the conventional clean room, the horizontal laminar flow clean room, the vertical laminar flow clean room and a fourth type that incorporates ideas from the previous types and is known as a clean air bench or hood. These clean rooms are briefly described. The origin of contamination and methods for controlling the contamination are discussed

  2. The effects of road building on arbuscular mycorrhizal fungal diversity in Huangshan Scenic Area.

    Science.gov (United States)

    Yang, Anna; Tang, Dongmei; Jin, Xiulong; Lu, Lin; Li, Xiaohong; Liu, Kun

    2018-01-22

    Arbuscular mycorrhizal (AM) fungi are vital soil microbes that connect many individual plants into a large functional organism via a vast mycelial network under the ground. In this study, the changes of soil AM fungal community in response to road-building disturbance caused by tourism development in Huangshan (Yellow Mountain) Scenic Area are assessed. Road building have brought negative effects on AM fungal community, inducing lower diversity parameters, including species number, spore density and diversity indices. However, the dominant genus and species of AM fungi which play key roles in the AM fungal community composition are quite similar before and after road building. Moreover, there are no significant differences in species richness of AM fungi associated with plants, suggesting the tolerance of AM fungal community to the disturbance of road building.

  3. Health effects associated with energy conservation measures in commercial buildings

    International Nuclear Information System (INIS)

    Stenner, R.D.; Baechler, M.C.

    1990-09-01

    Indoor air quality can conceivably be impacted by hundreds of different chemicals. More than 900 different organic compounds alone have been identified in indoor air. The health effects that could potentially arise from exposure to individual pollutants or mixtures of pollutants cover the full range of acute and chronic effects, including largely reversible responses, such as rashes and irritations, as well as irreversible toxic and carcinogenic effects. These indoor contaminants are emitted from a large variety of materials and substances that are widespread components of everyday life. Pacific Northwest Laboratory conducted a search of the peer-reviewed literature on health effects associated with indoor air contaminants for the Bonneville Power Administration to aid the agency in the preparation of environmental documents. The results of this search are reported in two volumes. Volume 1 is a summary of the results of the literature search; Volume 2 is the complete results of the literature search and contains all references to the material reviewed. 16 tabs

  4. Health effects associated with energy conservation measures in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, R.D.; Baechler, M.C.

    1990-09-01

    Indoor air quality can conceivably be impacted by hundreds of different chemicals. More than 900 different organic compounds alone have been identified in indoor air. The health effects that could potentially arise from exposure to individual pollutants or mixtures of pollutants cover the full range of acute and chronic effects, including largely reversible responses, such as rashes and irritations, as well as irreversible toxic and carcinogenic effects. These indoor contaminants are emitted from a large variety of materials and substances that are widespread components of everyday life. Pacific Northwest Laboratory conducted a search of the peer-reviewed literature on health effects associated with indoor air contaminants for the Bonneville Power Administration to aid the agency in the preparation of environmental documents. The results of this search are reported in two volumes. Volume 1 is a summary of the results of the literature search; Volume 2 is the complete results of the literature search and contains all references to the material reviewed. 16 tabs.

  5. Family Communication: Strategies for Building Effective Partnerships and Working Relationships

    Science.gov (United States)

    Shamash, Emily R.; Martin, Alyson M.

    2014-01-01

    This article offers a variety of strategies for pre-service and beginning teachers to utilize in order to create positive and effective relationships with families that are built on clear communication and trust. It is crucial for new and veteran teachers to understand the importance of successful communication with parents and families of…

  6. Comparison of glow discharge cleaning with Taylor-type discharge cleaning on JFT-2

    International Nuclear Information System (INIS)

    Yokokura, Kenji; Matsuzaki, Yoshimi; Tani, Takashi

    1983-01-01

    Method of glow discharge cleaning (GDC) was applied to JFT-2 tokamak and the cleaning effect of GDC was compared with that of taylor-type discharge cleaning (TDC) on the same machin. Results show clearly their individual characteristics to remove light impurities. Their abilities of surface cleaning were compared each other by observing cleanliness of sample surfaces with a AES and by measuring decay times of produced gas pressures during discharge cleanings with a mass-analyser. It was shown that TDC method is better by several times than GDC method from a mass-analyser measurement. Moreover discharge cleaning time necessary to reduce light impurities in the normal plasma to a certain level was compared by monitoring time evolution of radiation loss power with a bolometer, and the time by TDC was only one fifth of that by GDC. The advantage of TDC may come from the excellently high hydrogen flux which interacts with the limiter and the wall. (author)

  7. Effect of Zinc Oxide Nanoparticles and Sodium Hydroxide on the Self-Cleaning and Antibacterial Properties of Polyethylene Terephthalate

    Directory of Open Access Journals (Sweden)

    Mohammad Mirjalili

    2017-12-01

    Full Text Available In this study, the synthesis of zinc oxide nanoparticles was carried out, together with the hydrolysis of polyethylene terephthalate, using sodium hydroxide to increase surface activity and enhance nanoparticle adsorption. Polyester fabrics were treated with zinc acetate and sodium hydroxide in an ultrasonic bath, resulting in the formation of ZnO nanospheres. The presence of zinc oxide on the surface of the polyethylene terephthalate was confi rmed using scanning electron microscopy (SEM and energy-dispersive X-ray spectroscopy (EDS. The self-cleaning property of treated fabrics was evaluated through discolouring using methylene blue stain under solar irradiation. The antibacterial activities of the samples against common pathogenic bacteria, including Escherichia coli and Staphylococcus aureus, were also assessed. The results indicated that the photocatalytic and antibacterial activities of the ultrasound-treated polyethylene terephthalate improved significantly.

  8. Effects of titanium nanoparticles on self-cleaning and structural features of zinc-magnesium-phosphate glass

    International Nuclear Information System (INIS)

    Ismail, S.F.; Sahar, M.R.; Ghoshal, S.K.

    2016-01-01

    Graphical abstract: Water contact angle for sample S2, S3, S4 and S5. The water contact angle increased with increased the titanium NPs content (mol%). - Highlights: • ZnO–MgO–P_2O_5 embedded TiO_2 NPs prepared by conventional melt-quenching method. • The amorphous nature is confirmed by X-ray diffraction spectroscopy. • The structural characteristics of glasses is investigated using FTIR and Raman. • Wettability of the glasses surface by water contact angle. - Abstract: The loss of glass transparency on surface pollutants contamination unless inhibited not only causes vision obscurity but also responsible for major aesthetic damages of cultural heritage. It is due to the sticking of fine dirt particles on wetting layers, a complex process with several possible ramifications still to be clarified. We report the influence of titanium dioxide or titania (TiO_2) nanoparticles (NPs) on the structural and self-cleaning properties of zinc–magnesium–phosphate glasses. Following melt-quenching method glass samples of optimized composition (42 − x)P_2O_5–8MgO–50ZnO–xTiO_2 with x = 0, 1, 2, 3 and 4 mol% are prepared. XRD patterns verified their amorphous nature and TEM images revealed the nucleation of TiO_2 NPs of average diameter ≈4.05 ± 0.01 nm. Fourier transform infrared (FTIR) spectra displayed four absorption band centred at 1618–3438 cm"−"1, 902– 931 cm"−"1, 757–762 cm"−"1 and 531–560 cm"−"1. Raman spectra exhibited four peaks each accompanied by a blue-shift. Water contact angle is found to increase with the increase of titanium NPs concentration into the amorphous matrix. This knowledge can be used to set up strategies and selective treatments to preventing glass transparency loss via the modification of self-cleaning attributes.

  9. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    Directory of Open Access Journals (Sweden)

    N. Kenters

    2017-06-01

    Full Text Available Abstract Background In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested for their efficacy against spores of distinctive C. difficile PCR ribotypes. Methods Four different products were tested; 1 hydrogen peroxide 1.5%; 2 glucoprotamin 1.5%; 3 a mixture of ethanol, propane and N-alkyl amino propyl glycine; and 4 a mixture of didecyldimonium chloride, benzalkonium chloride, polyaminopropyl, biguanide and dimenthicone as active ingredients. Tiles were contaminated with a test solution containing a concentration of 5x106CFU/ml spores of C. difficile strains belonging to PCR ribotypes 010, 014 or 027. The tiles were left to dry for an hour and then wiped or sprayed with one of the sprays or wipes as intended by the manufacturers. When products neutralized after 5 min, microbiological cultures and ATP measures were performed. Results Irrespective of the disinfection method, the microbial count log10 reduction of C. difficile PCR ribotype 010 was highest, followed by the reduction of C. difficile 014 and C. difficile 027. Overall, the wipes performed better than the sprays with the same active ingredient. On average, although not significantly, a difference in relative light units (RLU reduction between the wipes and sprays was found. The wipes had a higher RLU log10 reduction, but no significant difference for RLU reduction was observed between the different C. difficile strains (p = 0.16. Conclusion C. difficile spores of PCR ribotypes 014 and 027 strains are more difficult to eradicate than non-toxigenic PCR ribotype 010. In general, impregnated cleaning/disinfection wipes performed better than ready-to-use sprays. Wipes with hydrogen peroxide (1.5% showed the highest bactericidal activity.

  10. Airborne Particulate Matter in Two Multi-Family Green Buildings: Concentrations and Effect of Ventilation and Occupant Behavior.

    Science.gov (United States)

    Patton, Allison P; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J; Krogmann, Uta; Mainelis, Gediminas

    2016-01-20

    There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m³) than in Building L (37 µg/m³); I/O was higher in Building E (1.3-2.0) than in Building L (0.5-0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents' exposure to PM in residential green buildings.

  11. Airborne Particulate Matter in Two Multi-Family Green Buildings: Concentrations and Effect of Ventilation and Occupant Behavior

    Directory of Open Access Journals (Sweden)

    Allison P. Patton

    2016-01-01

    Full Text Available There are limited data on air quality parameters, including airborne particulate matter (PM in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1 measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E and mechanical (Building L ventilation; (2 compare indoor and outdoor PM mass concentrations and their ratios (I/O in these buildings, taking into account the effects of occupant behavior; and (3 evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m3 than in Building L (37 µg/m3; I/O was higher in Building E (1.3–2.0 than in Building L (0.5–0.8 for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation are important factors affecting residents’ exposure to PM in residential green buildings.

  12. Summary report of the Banff clean energy dialogue : towards a truly Canadian clean energy strategy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    A clean energy strategy will allow Canada to seize opportunities for prosperity in a low-carbon future, while also contributing to the country's economic growth. This report outlined the conclusions drawn by representatives of major energy corporations and policy-makers who gathered to discuss Canada's clean energy plans for the future. Attendants at the meeting concluded that energy conservation and energy efficiency will play a prominent role in a successful clean energy strategy. However, a price on carbon is needed to emphasize the fundamental relationship between energy and the environment. A successful strategy will feature the following 4 overarching principles: (1) economic opportunity, (2) social responsibility, (3) environmental stewardship, and (4) international strategy in relation to trade and development of new markets. The role that federal, provincial and municipal governments will play in developing and implementing the strategy was also presented. The meeting was divided into the following 6 working sessions: (1) global context for a clean energy strategy, (2) why a Canadian clean energy strategy? Why now?, (3) key pillars of a Canadian clean energy strategy, (4) key building blocks of a national clean energy strategy, (5) a balanced Canadian framework, and (6) next steps. 1 fig.

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... intended to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... also aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  17. Clean Hands Count

    Science.gov (United States)

    ... intended to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... also aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... reminding healthcare providers to clean their hands. See: https://www.cdc.gov/handhygiene/campa... . Comments on this ... are allowed in accordance with our comment policy: http://www.cdc.gov/SocialMedia/Tools/... This video can ...

  19. Clean Water Act

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data represent geographic terms used within the Clean Water Act (CWA). The CWA establishes the basic structure for regulating the addition of pollutants...

  20. 6 Home Cleaning Recipes

    Science.gov (United States)

    ... aluminum, brass, ceramics, chrome, copper, fiberglass, glass/quartz, plastic, and steel. GLASS CLEANER 1 cup vinegar 1 ... originally filled with commercial cleaning products. Instead, reuse plastic water bottles.  Always place a label on the ...

  1. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ... It's in your hands - prevent sepsis in health care' A 5 May 2018 advocacy message from WHO - ...

  3. Steam cleaning device

    International Nuclear Information System (INIS)

    Karaki, Mikio; Muraoka, Shoichi.

    1985-01-01

    Purpose: To clean complicated and long objects to be cleaned having a structure like that of nuclear reactor fuel assembly. Constitution: Steams are blown from the bottom of a fuel assembly and soon condensated initially at the bottom of a vertical water tank due to water filled therein. Then, since water in the tank is warmed nearly to the saturation temperature, purified water is supplied from a injection device below to the injection device above the water tank on every device. In this way, since purified water is sprayed successively from below to above and steams are condensated in each of the places, the entire fuel assembly elongated in the vertical direction can be cleaned completely. Water in the reservoir goes upward like the steam flow and is drained together with the eliminated contaminations through an overflow pipe. After the cleaning has been completed, a main steam valve is closed and the drain valve is opened to drain water. (Kawakami, Y.)

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Published on May 5, 2017 This video for healthcare providers is intended to promote or encourage adherence ... role in their care by asking or reminding healthcare providers to clean their hands. See: https://www. ...

  6. Endovascular Therapy is Effective and Safe for Patients with Severe Ischemic Stroke: Pooled Analysis of IMS III and MR CLEAN Data

    Science.gov (United States)

    Broderick, Joseph P.; Berkhemer, Olvert A.; Palesch, Yuko Y.; Dippel, Diederik W.J.; Foster, Lydia D.; Roos, Yvo B.W.E.M.; van der Lugt, Aad; Tomsick, Thomas A.; Majoie, Charles B.L.M.; van Zwam, Wim H.; Demchuk, Andrew M.; van Oostenbrugge, Robert J.; Khatri, Pooja; Lingsma, Hester F.; Hill, Michael D.; Roozenbeek, Bob; Jauch, Edward C.; Jovin, Tudor G.; Yan, Bernard; von Kummer, Rüdiger; Molina, Carlos A.; Goyal, Mayank; Schonewille, Wouter J.; Mazighi, Mikael; Engelter, Stefan T.; Anderson, Craig S.; Spilker, Judith; Carrozzella, Janice; Ryckborst, Karla J.; Janis, L. Scott; Simpson, Kit

    2015-01-01

    Background and Purpose We assessed the effect of endovascular treatment in acute ischemic stroke patients with severe neurological deficit (NIHSS ≥20) following a pre-specified analysis plan. Methods The pooled analysis of the IMS III and MR CLEAN trial included participants with an NIHSS ≥20 prior to intravenous (IV) t-PA treatment (IMS III) or randomization (MR CLEAN) who were treated with IV t-PA ≤ 3 hours of stroke onset. Our hypothesis was that participants with severe stroke randomized to endovascular therapy following IV t-PA would have improved 90-day outcome (distribution of modified Rankin scale [mRS] scores), as compared to those who received IV t-PA alone. Results Among 342 participants in the pooled analysis (194 from IMS III, 148 from MR CLEAN), an ordinal logistic regression model showed that the endovascular group had superior 90-day outcome compared to the IV t-PA group (adjusted odds ratio [aOR] 1.78; 95% confidence interval [CI] 1.20-2.66). In the logistic regression model of the dichotomous outcome (mRS 0-2, or ‘functional independence’), the endovascular group had superior outcomes (aOR 1.97; 95% CI 1.09-3.56). Functional independence (mRS ≤2) at 90 days was 25% in the endovascular group as compared to 14% in the IV t-PA group. Conclusions Endovascular therapy following IV t-PA within 3 hours of symptom onset improves functional outcome at 90 days after severe ischemic stroke. PMID:26486865

  7. Building more effective sea level rise models for coastal management

    Science.gov (United States)

    Kidwell, D.; Buckel, C.; Collini, R.; Meckley, T.

    2017-12-01

    For over a decade, increased attention on coastal resilience and adaptation to sea level rise has resulted in a proliferation of predictive models and tools. This proliferation has enhanced our understanding of our vulnerability to sea level rise, but has also led to stakeholder fatigue in trying to realize the value of each advancement. These models vary in type and complexity ranging from GIS-based bathtub viewers to modeling systems that dynamically couple complex biophysical and geomorphic processes. These approaches and capabilities typically have the common purpose using scenarios of global and regional sea level change to inform adaptation and mitigation. In addition, stakeholders are often presented a plethora of options to address sea level rise issues from a variety of agencies, academics, and consulting firms. All of this can result in confusion, misapplication of a specific model/tool, and stakeholder feedback of "no more new science or tools, just help me understand which one to use". Concerns from stakeholders have led to the question; how do we move forward with sea level rise modeling? This presentation will provide a synthesis of the experiences and feedback derived from NOAA's Ecological Effects of Sea level Rise (EESLR) program to discuss the future of predictive sea level rise impact modeling. EESLR is an applied research program focused on the advancement of dynamic modeling capabilities in collaboration with local and regional stakeholders. Key concerns from stakeholder engagement include questions about model uncertainty, approaches for model validation, and a lack of cross-model comparisons. Effective communication of model/tool products, capabilities, and results is paramount to address these concerns. Looking forward, the most effective predictions of sea level rise impacts on our coast will be attained through a focus on coupled modeling systems, particularly those that connect natural processes and human response.

  8. Effects of non-uniform embedments on earthquake responses of nuclear reactor building

    International Nuclear Information System (INIS)

    Koyanagi, Y.; Okamoto, S.; Yoshida, K.; Inove, H.

    1989-01-01

    The nuclear reactor buildings have the portion embedded in soil. In the seismic design of such structures, it is essential to consider the effects of the embedment on the earthquake response. Most studies on these effects, however, assume the uniform embedment, i.e. the depth of the embedment is constant, which is convenient for the design and analysis. The behavior of the earthquake response considering the three-dimensional aspects of non-uniform embedment has not been made clear yet. In this paper, the authors evaluate the effects of the non-uniform embedment in an inclined ground surface on the earthquake response of a nuclear reactor building as illustrated. A typical PWR type reactor building is chosen as an analysis structure model. Four different types of embedment are set up for the comparison study. The three-dimensional analysis is carried out considering the geometry of embedment

  9. Effects of different SSI parameters on the floor response spectra of a nuclear reactor building

    International Nuclear Information System (INIS)

    Kabir, A.F.; Bolourchi, S.; Maryak, M.E.

    1991-01-01

    The effects of several critical soil-structure interaction (SSI) parameters on the floor response spectra (FRS) of a typical nuclear reactor building have been examined. These parameters are computation of soil impedance functions using different approaches, scattering effects (reductions in ground motion due to embedment and rigidity of building foundation) and strain dependency of soil dynamic properties. This paper reports that the significant conclusions of the study, which are applicable to a deeply embedded very rigid nuclear reactor building, are as follows: FRS generated without considering scattering effects are highly conservative; differences between FRS, generated considering strain-dependency of soil dynamic properties, and those generated suing low-strain values, are not significant; and the lumped-parameter approach of SSI calculations, which only uses a single value of soil shear modulus in impedance calculations, may not be able to properly compute the soil impedances for a soil deposit with irregularly varying properties with depth

  10. Regulatory odour model development: Survey of modelling tools and datasets with focus on building effects

    DEFF Research Database (Denmark)

    Olesen, H. R.; Løfstrøm, P.; Berkowicz, R.

    dispersion models for estimating local concentration levels in general. However, the report focuses on some particular issues, which are relevant for subsequent work on odour due to animal production. An issue of primary concern is the effect that buildings (stables) have on flow and dispersion. The handling...... of building effects is a complicated problem, and a major part of the report is devoted to the treatment of building effects in dispersion models......A project within the framework of a larger research programme, Action Plan for the Aquatic Environment III (VMP III) aims towards improving an atmospheric dispersion model (OML). The OML model is used for regulatory applications in Denmark, and it is the candidate model to be used also in future...

  11. Chemical cleaning, decontamination and corrosion

    International Nuclear Information System (INIS)

    Gadiyar, H.S.; Das Chintamani; Gaonkar, K.B.

    1991-01-01

    Chemical cleaning of process equipments and pipings in chemical/petrochemical industries is necessitated for improving operation, for preventing premature failures and for avoiding contamination. In developing a chemical formulation for cleaning equipments, the important aspects to be considered include (i) effective removal of corrosion products and scales, (ii) minimum corrosion of the base metal, (iii) easy to handle chemicals and (iv) economic viability. As on date, a wide variety of chemical formulations are available, many of them are either proprietory or patented. For evolving an effective formulation, knowledge of the oxides of various metals and alloys on the one hand and acid concentration, complexing agents and inhibitors to be incorporated on the other, is quite essential. Organic acids like citric acid, acetic acid and formic acid are more popular ones, often used with EDTA for effective removal of corrosion products from ferrous components. The report enumerates some of the concepts in developing effective formulations for chemical cleaning of carbon steel components and further, makes an attempt to suggest simple formulations to be developed for chemical decontamination. (author). 6 refs., 3 fi gs., 4 tabs

  12. TiO 2 Thin Films Prepared via Adsorptive Self-Assembly for Self-Cleaning Applications

    KAUST Repository

    Xi, Baojuan; Verma, Lalit Kumar; Li, Jing; Bhatia, Charanjit Singh; Danner, Aaron James; Yang, Hyunsoo; Zeng, Hua Chun

    2012-01-01

    oxidation processes for wastewater and bactericidal treatments, self-cleaning window glass for green intelligent buildings, dye-sensitized solar cells, solid-state semiconductor metal-oxide solar cells, self-cleaning glass for photovoltaic devices

  13. Clean Air Markets - Monitoring Surface Water Chemistry

    Science.gov (United States)

    Learn about how EPA uses Long Term Monitoring (LTM) and Temporily Integrated Monitoring of Ecosystems (TIME) to track the effect of the Clean Air Act Amendments on acidity of surface waters in the eastern U.S.

  14. Development of an atmospheric diffusion numerical model for a nuclear facility. Numerical calculation method incorporating building effects

    International Nuclear Information System (INIS)

    Sada, Koichi; Michioka, Takenobu; Ichikawa, Yoichi

    2002-01-01

    Because effluent gas is sometimes released from low positions, viz., near the ground surface and around buildings, the effects caused by buildings within the site area are not negligible for gas diffusion predictions. For these reasons, the effects caused by buildings for gas diffusion are considered under the terrain following calculation coordinate system in this report. Numerical calculation meshes on the ground surface are treated as the building with the adaptation of wall function techniques of turbulent quantities in the flow calculations using a turbulence closure model. The reflection conditions of released particles on building surfaces are taken into consideration in the diffusion calculation using the Lagrangian particle model. Obtained flow and diffusion calculation results are compared with those of wind tunnel experiments around the building. It was apparent that features observed in a wind tunnel, viz., the formation of cavity regions behind the building and the gas diffusion to the ground surface behind the building, are also obtained by numerical calculation. (author)

  15. Effect of LED lighting on the cooling and heating loads in office buildings

    International Nuclear Information System (INIS)

    Ahn, Byung-Lip; Jang, Cheol-Yong; Leigh, Seung-Bok; Yoo, Seunghwan; Jeong, Hakgeun

    2014-01-01

    Highlights: • Application of heat control strategy reduces total energy consumption of LED lighting. • Convective heat from LED lighting should be emitted outdoors during cooling period. • Seasonal optimization of convective heat lowers total energy consumption. - Abstract: LED lighting has the potential to provide energy savings, and in many countries, there are policies to encourage its use owing to its higher efficiency and longer life in comparison to other lighting fixtures. However, since 75–85% of the light electric power in LED lights is still generated as heat, the sole use of LED lighting in a building could have a negative effect on the cooling load. In this paper, we study the heating properties of LED lighting and establish a management strategy to exploit these properties to reduce the energy used for heating and cooling of buildings. Using a simulation program, the energy consumption of the Green Building in Daejeon, Korea, and the virtual building provided by the U.S. Department of Energy (DOE) was computed according for different light fixtures. A control strategy is more applicable to LED lighting than to general fluorescent lighting, especially for the cooling of a building, because the use of a return-air duct and the heat sinks on the LED fixtures allow the heat to be better directed. Deployment of LED lights in combination with such a control strategy can help to increase the energy efficiency of a building

  16. Effectiveness of daylighting design and occupant visual satisfaction in a LEED gold laboratory building

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Ying; Oswald, Anne [Department of Design and Environmental Analysis, Cornell University, Ithaca, NY 14853 (United States); Yang, Xiaodi [School of Architecture, Carnegie Mellon University, Pittsburgh, PA 15213 (United States)

    2011-01-15

    Using daylight as primary light source has been widely recognized as an important strategy to reduce building energy demand and enhance indoor environment quality. However, to design and operate a building to make full use of daylight, which is a dynamic light source, to meet diverse occupant needs remains a challenge. This paper reports a post-occupancy study of the visual environment in a laboratory building on a university campus, and puts a spotlight on the building occupants as it examines the effectiveness of the daylighting design and systems integration in creating a visual environment to support occupant comfort and satisfaction while reducing artificial lighting demand. Results show generally high satisfaction with daylit work environment and positive effect of the horizontal shading strategy. Issues about the integration between daylighting and electric lighting systems and level of occupant control are identified and discussed for improving the effectiveness of daylighting and enhancing the quality of the visual environment in the building of study. A multiple-tool methodology is developed and tested, which included occupant surveys, interviews, illuminance measurements, continuous data loggers, fisheye-lens camera and glare-identifying software, and documentation of spatial settings, systems features, and user behavior. (author)

  17. Shielding effect of building to natural radiation and its influence to population dose evaluation

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Itoh, Kazuo; Yoshimura, Toshiaki.

    1980-01-01

    This work investigated the shielding effect of the building which is indispensable for the accurate evaluation of the population dose of external exposure from natural radiation. At first, the attenuation coefficients of various building materials were measured and found to agree with the calculated values within 10% errors. The shielding factors of these materials were calculated from the calculated attenuation coefficients and buildup factors. The shielding factors of the wall, window, roof and floor were calculated separately by settling the model houses and combining the shielding factors of the building materials used, and then the shielding factor of the whole building was obtained by use of the opening fraction of the wall and the fractions of the wall, roof and floor areas to the total floor area. The influence of the shielding effect of the building is well represented by the occupancy factor which is the ratio of the group doses including that shielding effect to those excluding it. The occupancy factor lies between 0.9 and 1.0 for four specified districts, Tokyo, Osaka, Ibaraki and Nagano. (author)

  18. Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Woods, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-01-01

    This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. An error in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.

  19. Engineering Integration: Building a Quick and Effective Faculty Seminar

    Directory of Open Access Journals (Sweden)

    Kate Peterson

    2012-12-01

    Full Text Available In the spring of 2010, the Science & Engineering Library of the University of Minnesota-Twin Cities partnered with the Information Literacy Librarian and offered a faculty seminar to the College of Science and Engineering. The seminar’s goals included 1. refreshing and expanding faculty’s knowledge of information and 21st century literacies and 2. creating a community of faculty committed to developing student skills in finding, evaluating and synthesizing information in their academic coursework and into their professional careers. Overall, the seminar increased faculty understanding of services and expertise of the libraries, and 21st century literacies. It also developed and strengthened ties between individual faculty members and their subject librarians, leading to a mix of outcomes from a faculty member partnering on a grant the Libraries applied for to course integrated instruction sessions to faculty participating in an e-textbook pilot. This seminar provides a strong model for re-framing information literacy in the context of teaching and learning in science and engineering, giving librarians an opportunity to strengthen relationships and increase liaison effectiveness.

  20. Organizational leadership for building effective health care teams.

    Science.gov (United States)

    Taplin, Stephen H; Foster, Mary K; Shortell, Stephen M

    2013-01-01

    The movement toward accountable care organizations and patient-centered medical homes will increase with implementation of the Affordable Care Act (ACA). The ACA will therefore give further impetus to the growing importance of teams in health care. Teams typically involve 2 or more people embedded in a larger social system who differentiate their roles, share common goals, interact with each other, and perform tasks affecting others. Multiple team types fit within this definition, and they all need support from leadership to succeed. Teams have been invoked as a necessary tool to address the needs of patients with multiple chronic conditions and to address medical workforce shortages. Invoking teams, however, is much easier than making them function effectively, so we need to consider the implications of the growing emphasis on teams. Although the ACA will spur team development, organizational leadership must use what we know now to train, support, and incentivize team function. Meanwhile, we must also advance research regarding teams in health care to give those leaders more evidence to guide their work.

  1. Deriving the effect of wind speed on clean marine aerosol optical properties using the A-Train satellites

    Directory of Open Access Journals (Sweden)

    V. P. Kiliyanpilakkil

    2011-11-01

    Full Text Available The relationship between "clean marine" aerosol optical properties and ocean surface wind speed is explored using remotely sensed data from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP on board the CALIPSO satellite and the Advanced Microwave Scanning Radiometer (AMSR-E on board the AQUA satellite. Detailed data analyses are carried out over 15 regions selected to be representative of different areas of the global ocean for the time period from June 2006 to April 2011. Based on remotely sensed optical properties the CALIPSO algorithm is capable of discriminating "clean marine" aerosols from other types often present over the ocean (such as urban/industrial pollution, desert dust and biomass burning. The global mean optical depth of "clean marine" aerosol at 532 nm (AOD532 is found to be 0.052 ± 0.038 (mean plus or minus standard deviation. The mean layer integrated particulate depolarization ratio of marine aerosols is 0.02 ± 0.016. Integrated attenuated backscatter and color ratio of marine aerosols at 532 nm were found to be 0.003 ± 0.002 sr−1 and 0.530 ± 0.149, respectively. A logistic regression between AOD532 and 10-m surface wind speed (U10 revealed three distinct regimes. For U10 ≤ 4 m s−1 the mean CALIPSO-derived AOD532 is found to be 0.02 ± 0.003 with little dependency on the surface wind speed. For 4 < U10 ≤ 12 m s−1, representing the dominant fraction of all available data, marine aerosol optical depth is linearly correlated with the surface wind speed values, with a slope of 0.006 s m−1. In this intermediate wind speed region, the AOD532 vs. U10 regression slope derived here is comparable to previously reported values. At very high wind speed values (U10 > 18 m s−1, the AOD532-wind speed relationship

  2. Clean coal technology

    International Nuclear Information System (INIS)

    Abelson, P.H.

    1990-01-01

    One of the major technology challenges in the next decade will be to develop means of using coal imaginatively as a source of chemicals and in a more energy-efficient manner. The Clean Air Act will help to diminish the acid rain but will not reduce CO 2 emissions. The Department of Energy (DOE) is fostering many innovations that are likely to have a positive effect on coal usage. Of the different innovations in the use of coal fostered by DOE, two are of particular interest. One is the new pressurized fluid bed combustion (PFBC) combined-cycle demonstration. The PFBC plant now becoming operational can reduce SO 2 emissions by more than 90% and NO x emissions by 50-70%. A second new technology co-sponsored by DOE is the Encoal mild coal gasification project that will convert a sub-bituminous low-BTU coal into a useful higher BTU solid while producing significant amounts of a liquid fuel

  3. Effects of titanium nanoparticles on self-cleaning and structural features of zinc-magnesium-phosphate glass

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, S.F.; Sahar, M.R., E-mail: mrahim057@gmail.com; Ghoshal, S.K.

    2016-02-15

    Graphical abstract: Water contact angle for sample S2, S3, S4 and S5. The water contact angle increased with increased the titanium NPs content (mol%). - Highlights: • ZnO–MgO–P{sub 2}O{sub 5} embedded TiO{sub 2} NPs prepared by conventional melt-quenching method. • The amorphous nature is confirmed by X-ray diffraction spectroscopy. • The structural characteristics of glasses is investigated using FTIR and Raman. • Wettability of the glasses surface by water contact angle. - Abstract: The loss of glass transparency on surface pollutants contamination unless inhibited not only causes vision obscurity but also responsible for major aesthetic damages of cultural heritage. It is due to the sticking of fine dirt particles on wetting layers, a complex process with several possible ramifications still to be clarified. We report the influence of titanium dioxide or titania (TiO{sub 2}) nanoparticles (NPs) on the structural and self-cleaning properties of zinc–magnesium–phosphate glasses. Following melt-quenching method glass samples of optimized composition (42 − x)P{sub 2}O{sub 5}–8MgO–50ZnO–xTiO{sub 2} with x = 0, 1, 2, 3 and 4 mol% are prepared. XRD patterns verified their amorphous nature and TEM images revealed the nucleation of TiO{sub 2} NPs of average diameter ≈4.05 ± 0.01 nm. Fourier transform infrared (FTIR) spectra displayed four absorption band centred at 1618–3438 cm{sup −1}, 902– 931 cm{sup −1}, 757–762 cm{sup −1} and 531–560 cm{sup −1}. Raman spectra exhibited four peaks each accompanied by a blue-shift. Water contact angle is found to increase with the increase of titanium NPs concentration into the amorphous matrix. This knowledge can be used to set up strategies and selective treatments to preventing glass transparency loss via the modification of self-cleaning attributes.

  4. Emerging forward osmosis (FO) technologies and challenges ahead for clean water and clean energy applications

    KAUST Repository

    Chung, Tai-Shung

    2012-08-01

    The purpose of this short review is to share our understanding and perspectives with the chemical, environmental, water and osmotic power communities on FO processes in order to conduct meaningful R & D and develop effective and sustainable FO technologies for clean water and clean energy. © 2012 Elsevier Ltd. All rights reserved.

  5. Emerging forward osmosis (FO) technologies and challenges ahead for clean water and clean energy applications

    KAUST Repository

    Chung, Tai-Shung; Li, Xue; Ong, Rui Chin; Ge, Qingchun; Wang, Honglei; Han, Gang

    2012-01-01

    The purpose of this short review is to share our understanding and perspectives with the chemical, environmental, water and osmotic power communities on FO processes in order to conduct meaningful R & D and develop effective and sustainable FO technologies for clean water and clean energy. © 2012 Elsevier Ltd. All rights reserved.

  6. The ratio of effective building height to street width governs dispersion of local vehicle emissions

    Science.gov (United States)

    Schulte, Nico; Tan, Si; Venkatram, Akula

    2015-07-01

    Analysis of data collected in street canyons located in Hanover, Germany and Los Angeles, USA, suggests that street-level concentrations of vehicle-related pollutants can be estimated with a model that assumes that vertical turbulent transport of emissions dominates the governing processes. The dispersion model relates surface concentrations to traffic flow rate, the effective aspect ratio of the street, and roof level turbulence. The dispersion model indicates that magnification of concentrations relative to those in the absence of buildings is most sensitive to the aspect ratio of the street, which is the ratio of the effective height of the buildings on the street to the width of the street. This result can be useful in the design of transit oriented developments that increase building density to reduce emissions from transportation.

  7. The Effect of Anisotropy of Building Materials on the Moisture Transfer

    Directory of Open Access Journals (Sweden)

    J. Drchalová

    2000-01-01

    Full Text Available The effect of anisotropy of building materials on the moisture transfer in the design of envelope parts of building structures is studied. Two typical fibre containing plate building materials produced in the Czech Republic, Dekalux and Dekalit P, are chosen for the demonstration of this effect. Experimental results show that while for lighter Dekalit P, an order of magnitude difference in the moisture diffusivities k for the two basic orientations, i.e. along and across the plate, is observed, for the heavier Dekalux the differences in k are within the errorbar of the experimental method. As follows from the experimental results, compacting of surface layers of the plates of light fibred materials is very favorable from the point of view of moisture penetration but one should keep in mind that any local damage of the surface layer can result in a considerably faster moisture transfer in the direction along the plate.

  8. Roles of Urban Tree Canopy and Buildings in Urban Heat Island Effects: Parameterization and Preliminary Results

    Science.gov (United States)

    Loughner, Christopher P.; Allen, Dale J.; Zhang, Da-Lin; Pickering, Kenneth E.; Dickerson, Russell R.; Landry, Laura

    2012-01-01

    Urban heat island (UHI) effects can strengthen heat waves and air pollution episodes. In this study, the dampening impact of urban trees on the UHI during an extreme heat wave in the Washington, D.C., and Baltimore, Maryland, metropolitan area is examined by incorporating trees, soil, and grass into the coupled Weather Research and Forecasting model and an urban canopy model (WRF-UCM). By parameterizing the effects of these natural surfaces alongside roadways and buildings, the modified WRF-UCM is used to investigate how urban trees, soil, and grass dampen the UHI. The modified model was run with 50% tree cover over urban roads and a 10% decrease in the width of urban streets to make space for soil and grass alongside the roads and buildings. Results show that, averaged over all urban areas, the added vegetation decreases surface air temperature in urban street canyons by 4.1 K and road-surface and building-wall temperatures by 15.4 and 8.9 K, respectively, as a result of tree shading and evapotranspiration. These temperature changes propagate downwind and alter the temperature gradient associated with the Chesapeake Bay breeze and, therefore, alter the strength of the bay breeze. The impact of building height on the UHI shows that decreasing commercial building heights by 8 m and residential building heights by 2.5 m results in up to 0.4-K higher daytime surface and near-surface air temperatures because of less building shading and up to 1.2-K lower nighttime temperatures because of less longwave radiative trapping in urban street canyons.

  9. Abort Gap Cleaning for LHC Run 2

    Energy Technology Data Exchange (ETDEWEB)

    Uythoven, Jan [CERN; Boccardi, Andrea [CERN; Bravin, Enrico [CERN; Goddard, Brennan [CERN; Hemelsoet, Georges-Henry [CERN; Höfle, Wolfgang [CERN; Jacquet, Delphine [CERN; Kain, Verena [CERN; Mazzoni, Stefano [CERN; Meddahi, Malika [CERN; Valuch, Daniel [CERN; Gianfelice-Wendt, Eliana [Fermilab

    2014-07-01

    To minimize the beam losses at the moment of an LHC beam dump the 3 μs long abort gap should contain as few particles as possible. Its population can be minimised by abort gap cleaning using the LHC transverse damper system. The LHC Run 1 experience is briefly recalled; changes foreseen for the LHC Run 2 are presented. They include improvements in the observation of the abort gap population and the mechanism to decide if cleaning is required, changes to the hardware of the transverse dampers to reduce the detrimental effect on the luminosity lifetime and proposed changes to the applied cleaning algorithms.

  10. Abort Gap Cleaning for LHC Run 2

    CERN Document Server

    Uythoven, J; Bravin, E; Goddard, B; Hemelsoet, GH; Höfle, W; Jacquet, D; Kain, V; Mazzoni, S; Meddahi, M; Valuch, D

    2015-01-01

    To minimise the beam losses at the moment of an LHC beam dump the 3 μs long abort gap should contain as few particles as possible. Its population can be minimised by abort gap cleaning using the LHC transverse damper system. The LHC Run 1 experience is briefly recalled; changes foreseen for the LHC Run 2 are presented. They include improvements in the observation of the abort gap population and the mechanism to decide if cleaning is required, changes to the hardware of the transverse dampers to reduce the detrimental effect on the luminosity lifetime and proposed changes to the applied cleaning algorithms.

  11. The effects of electrode cleaning and conditioning on the performance of high-energy, pulsed-power devices

    Energy Technology Data Exchange (ETDEWEB)

    Cuneo, M.E.

    1998-09-01

    High-energy pulsed-power devices routinely access field strengths above those at which broad-area, cathode-initiated, high-voltage vacuum-breakdown occur (> 1e7--3e7 V/m). Examples include magnetically-insulated-transmission-lines and current convolutes, high-current-density electron and ion diodes, high-power microwave devices, and cavities and other structures for electrostatic and RF accelerators. Energy deposited in anode surfaces may exceed anode plasma thermal-desorption creation thresholds on the time-scale of the pulse. Stimulated desorption by electron or photon bombardment can also lead to plasma formation on electrode or insulator surfaces. Device performance is limited above these thresholds, particularly in pulse length and energy, by the formation and expansion of plasmas formed primarily from electrode contaminants. In-situ conditioning techniques to modify and eliminate the contaminants through multiple high-voltage pulses, low base pressures, RF discharge cleaning, heating, surface coatings, and ion- and electron-beam surface treatment allow access to new regimes of performance through control of plasma formation and modification of the plasma properties. Experimental and theoretical progress from a variety of devices and small scale experiments with a variety of treatment methods will be reviewed and recommendations given for future work.

  12. Is dry cleaning all wet?

    International Nuclear Information System (INIS)

    Ryan, M.

    1993-01-01

    Chemical solvents from dry cleaning, particularly perchloroethylene (perc), have contributed to groundwater contamination, significant levels of air pollution in and around cleaners, and chemical accumulation in food. Questions are being raised about the process of cleaning clothes with chemical, and other less toxic cleaning methods are being explored. The EPA has focused attention on the 50 year old Friedburg method of cleaning, Ecoclean, which uses no dangerous chemicals and achieves comparable results. Unfortunately, the cleaning industry is resistant to change, so cutting back on amount of clothes that need dry cleaning and making sure labels aren't exaggerating when they say dry clean only, is frequently the only consumer option now

  13. Ultrasonic aqueous cleaning as a replacement for chlorinated solvent cleaning

    International Nuclear Information System (INIS)

    Thompson, L.M.; Simandl, R.F.

    1992-01-01

    The Oak Ridge Y-12 Plant has been involved in the replacement of chlorinated solvents since 1982. One of the most successful replacement efforts has been the substitution of vapor degreasers or soak tanks using chlorinated solvents with ultrasonic cleaning using aqueous detergents. Recently, funding was obtained from the Department of Energy Office (DOE) of Technology Development to demonstrate this technology. A unit has been procured and installed in the vacuum pump shop area to replace the use of a solvent soak tank. Initially, the solvents used in the shop were CFC-113 and a commercial brand cleaner which contained both perchloroethylene and methylene chloride. While the ultrasonic unit was being procured, a terpene-based solvent was used. Generally, parts were soaked overnight in order to soften baked-on vanish. Many times, wire brushing was used to help remove remaining contamination. Initial testing with the ultrasonic cleaner indicated cleaning times of 20 min were as effective as the overnight solvent soaks in removing contamination. Wire brushing was also not required following the ultrasonic cleaning as was sometimes required with the solvent soak

  14. Interactive effects of fire and large herbivores on web-building spiders.

    Science.gov (United States)

    Foster, C N; Barton, P S; Wood, J T; Lindenmayer, D B

    2015-09-01

    Altered disturbance regimes are a major driver of biodiversity loss worldwide. Maintaining or re-creating natural disturbance regimes is therefore the focus of many conservation programmes. A key challenge, however, is to understand how co-occurring disturbances interact to affect biodiversity. We experimentally tested for the interactive effects of prescribed fire and large macropod herbivores on the web-building spider assemblage of a eucalypt forest understorey and investigated the role of vegetation in mediating these effects using path analysis. Fire had strong negative effects on the density of web-building spiders, which were partly mediated by effects on vegetation structure, while negative effects of large herbivores on web density were not related to changes in vegetation. Fire amplified the effects of large herbivores on spiders, both via vegetation-mediated pathways and by increasing herbivore activity. The importance of vegetation-mediated pathways and fire-herbivore interactions differed for web density and richness and also differed between web types. Our results demonstrate that for some groups of web-building spiders, the effects of co-occurring disturbance drivers may be mostly additive, whereas for other groups, interactions between drivers can amplify disturbance effects. In our study system, the use of prescribed fire in the presence of high densities of herbivores could lead to reduced densities and altered composition of web-building spiders, with potential cascading effects through the arthropod food web. Our study highlights the importance of considering both the independent and interactive effects of disturbances, as well as the mechanisms driving their effects, in the management of disturbance regimes.

  15. Intercultural Leadership Toolkit for Librarians: Building Awareness to Effectively Serve Diverse Multicultural Populations

    Science.gov (United States)

    Allard, Suzie; Mehra, Bharat; Qayyum, M. Asim

    2007-01-01

    This paper presents five tools for librarians to use in building effective intercultural communication that reaches out to diverse populations. Librarians can more successfully cross intercultural boundaries if they are aware of the key tenets of intercultural communication and information provision, and then apply the five leadership tools in…

  16. Strategies Towards Effective Management of Higher Education for Building a Culture of Peace in Nigeria

    Science.gov (United States)

    Asiyai, Romina Ifeoma

    2015-01-01

    This study was aimed at investigating strategies for effective management of higher education for building a culture of peace in Nigeria. Four research questions and four hypotheses guided the investigation. The study is a survey research which adopted the ex-post-facto design. The respondents comprised of one thousand four hundred and eighty…

  17. Effectiveness of Training Model Capacity Building for Entrepreneurship Women Based Empowerment Community

    Science.gov (United States)

    Idawati; Mahmud, Alimuddin; Dirawan, Gufran Darma

    2016-01-01

    The purpose of this research was to determine the effectiveness of a training model for capacity building of women entrepreneurship community-based. Research type approach Research and Development Model, which refers to the model of development research that developed by Romiszowki (1996) combined with a model of development Sugiono (2011) it was…

  18. Effects of Traditional Advertising and Social Messages on Brand-Building Metrics and Customer Acquisition

    NARCIS (Netherlands)

    De Vries, Lisette; Gensler, Sonja; Leeflang, Pieter

    This study examines the relative effectiveness of traditional advertising, impressions generated through firm-to-consumer (F2C) messages on Facebook, and the volume and valence of consumer-to-consumer (C2C) messages on Twitter and web forums for brand-building and customer acquisition efforts. The

  19. Effects of heat and electricity saving measures in district-heated multistory residential buildings

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed the potential for energy savings in district heated buildings. • Measures that reduce more peak load production give higher primary energy savings. • Efficient appliances increase heat demand but give net primary energy savings. • Efficient appliances give the largest net primary energy savings. - Abstract: The effects of heat and electricity saving measures in district-heated buildings can be complex because these depend not only on how energy is used on the demand side but also on how energy is provided from the supply side. In this study, we analyze the effects of heat and electricity saving measures in multistory concrete-framed and wood-framed versions of an existing district-heated building and examine the impacts of the reduced energy demand on different district heat (DH) production configurations. The energy saving measures considered are for domestic hot water reduction, building thermal envelope improvement, ventilation heat recovery (VHR), and household electricity savings. Our analysis is based on a measured heat load profile of an existing DH production system in Växjö, Sweden. Based on the measured heat load profile, we model three minimum-cost DH production system using plausible environmental and socio-political scenarios. Then, we investigate the primary energy implications of the energy saving measures applied to the two versions of the existing building, taking into account the changed DH demand, changed cogenerated electricity, and changed electricity use due to heat and electricity saving measures. Our results show that the difference between the final and primary energy savings of the concrete-framed and wood-framed versions of the case-study building is minor. The primary energy efficiency of the energy saving measures depends on the type of measure and on the composition of the DH production system. Of the various energy saving measures explored, electricity savings give the highest primary energy savings

  20. Probabilistic analysis of the torsional effects on the tall building resistance due to earthquake even

    Science.gov (United States)

    Králik, Juraj; Králik, Juraj

    2017-07-01

    The paper presents the results from the deterministic and probabilistic analysis of the accidental torsional effect of reinforced concrete tall buildings due to earthquake even. The core-column structural system was considered with various configurations in plane. The methodology of the seismic analysis of the building structures in Eurocode 8 and JCSS 2000 is discussed. The possibilities of the utilization the LHS method to analyze the extensive and robust tasks in FEM is presented. The influence of the various input parameters (material, geometry, soil, masses and others) is considered. The deterministic and probability analysis of the seismic resistance of the structure was calculated in the ANSYS program.

  1. Clean utilization of coal

    International Nuclear Information System (INIS)

    Yueruem, Y.

    1992-01-01

    This volume contains 23 lectures presented at the Advanced Study Institute on 'Chemistry and Chemical Engineering of Catalytic Solid Fuel Conversion for the Production of Clean Synthetic Fuels', which was held at Akcay, Edremit, Turkey, between 21 July and August 3, 1991. Three main subjects: structure and reactivity of coal; cleaning of coal and its products, and factors affecting the environmental balance of energy usage and solutions for the future, were discussed in the Institute and these are presented under six groups in the book: Part 1. Structure and reactivity of coal; Part 2. Factors affecting environmental balance; Part 3. Pre-usage cleaning operations and processes; Part 4. Upgrading of coal liquids and gases; Part 5. Oxygen enriched processes; and Part 6. Probable future solution for energy and pollution problems. Separate abstracts have been prepared for all the lectures

  2. Clean room actuators

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Toshiro

    1987-06-01

    This report explains on the present status of the clean room actuators including the author's research results. In a clean room, there exists a possibility of dust generation, even when a direct human work is eliminated by the use of robots or automatic machines, from the machines themselves. For this, it is important to develop such clean robots and transfer/positioning mechanism that do not generate dusts, and to develop an actuator and its control technique. Topics described in the report are as follows: 1. Prevention of dust diffusion by means of sealing. 2. Elimination of mechanical contact (Linear induction motor and pneumatic float, linear motor and magnetic attraction float, linear motor and air bearing, and magnetic bearing). 3. Contactless actuator having a positioning mechanism (Use of linear step motor and rotary contactless actuator). (15 figs, 11 refs)

  3. The Clean Air Act

    International Nuclear Information System (INIS)

    Coburn, L.L.

    1990-01-01

    The Clean Air Act amendments alter the complex laws affecting atmospheric pollution and at the same time have broad implications for energy. Specifically, the Clean Air Act amendments for the first time deal with the environmental problem of acid deposition in a way that minimizes energy and economic impacts. By relying upon a market-based system of emission trading, a least cost solution will be used to reduce sulfur dioxide (SO 2 ) emissions by almost 40 percent. The emission trading system is the centerpiece of the Clean Air Act (CAA) amendments effort to resolve energy and environmental interactions in a manner that will maximize environmental solutions while minimizing energy impacts. This paper will explore how the present CAA amendments deal with the emission trading system and the likely impact of the emission trading system and the CAA amendments upon the electric power industry

  4. Pool water cleaning facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro [Hitachi Ltd., Tokyo (Japan); Asano, Takashi

    1998-05-29

    Only one system comprising a suppression poor water cleaning system (SPCU) and a filtration desalting tower (F/D) is connected for a plurality of nuclear power plants. Pipelines/valves for connecting the one system of the SPCU pump, the F/D and the plurality of nuclear power plants are disposed, and the system is used in common with the plurality of nuclear power plants. Pipelines/valves for connecting a pipeline for passing SP water to the commonly used SPCU pump and a skimmer surge tank are disposed, and fuel pool water is cooled and cleaned by the commonly used SPCU pump and the commonly used F/D. The number of SPCU pumps and the F/D facilities can be reduced, and a fuel pool water cooling operation mode and a fuel pool water cleaning operation mode which were conducted by an FPC pump so far are conducted by the SPCU pump. (N.H.)

  5. Keeping condensers clean

    Energy Technology Data Exchange (ETDEWEB)

    Wicker, K.

    2006-04-15

    The humble condenser is among the biggest contributors to a steam power plant's efficiency. But although a clean condenser can provide great economic benefit, a dirty one can raise plant heat rate, resulting in large losses of generation revenue and/or unnecessarily high fuel bills. Conventional methods for cleaning fouled tubes range form chemicals to scrapers to brushes and hydro-blasters. This article compares the available options and describes how one power station, Omaha Public Power District's 600 MW North Omaha coal-fired power station, cleaned up its act. The makeup and cooling water of all its five units comes from the Missouri River. 6 figs.

  6. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    Science.gov (United States)

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  7. Ventilation Positive Pressure Intervention Effect on Indoor Air Quality in a School Building with Moisture Problems

    Science.gov (United States)

    Vornanen-Winqvist, Camilla; Järvi, Kati; Toomla, Sander; Ahmed, Kaiser; Andersson, Maria A.; Mikkola, Raimo; Marik, Tamás; Salonen, Heidi

    2018-01-01

    This case study investigates the effects of ventilation intervention on measured and perceived indoor air quality (IAQ) in a repaired school where occupants reported IAQ problems. Occupants’ symptoms were suspected to be related to the impurities leaked indoors through the building envelope. The study’s aim was to determine whether a positive pressure of 5–7 Pa prevents the infiltration of harmful chemical and microbiological agents from structures, thus decreasing symptoms and discomfort. Ventilation intervention was conducted in a building section comprising 12 classrooms and was completed with IAQ measurements and occupants’ questionnaires. After intervention, the concentration of total volatile organic compounds (TVOC) and fine particulate matter (PM2.5) decreased, and occupants’ negative perceptions became more moderate compared to those for other parts of the building. The indoor mycobiota differed in species composition from the outdoor mycobiota, and changed remarkably with the intervention, indicating that some species may have emanated from an indoor source before the intervention. PMID:29385772

  8. Ventilation Positive Pressure Intervention Effect on Indoor Air Quality in a School Building with Moisture Problems.

    Science.gov (United States)

    Vornanen-Winqvist, Camilla; Järvi, Kati; Toomla, Sander; Ahmed, Kaiser; Andersson, Maria A; Mikkola, Raimo; Marik, Tamás; Kredics, László; Salonen, Heidi; Kurnitski, Jarek

    2018-01-30

    This case study investigates the effects of ventilation intervention on measured and perceived indoor air quality (IAQ) in a repaired school where occupants reported IAQ problems. Occupants' symptoms were suspected to be related to the impurities leaked indoors through the building envelope. The study's aim was to determine whether a positive pressure of 5-7 Pa prevents the infiltration of harmful chemical and microbiological agents from structures, thus decreasing symptoms and discomfort. Ventilation intervention was conducted in a building section comprising 12 classrooms and was completed with IAQ measurements and occupants' questionnaires. After intervention, the concentration of total volatile organic compounds (TVOC) and fine particulate matter (PM 2.5 ) decreased, and occupants' negative perceptions became more moderate compared to those for other parts of the building. The indoor mycobiota differed in species composition from the outdoor mycobiota, and changed remarkably with the intervention, indicating that some species may have emanated from an indoor source before the intervention.

  9. Key Performance Indicators for Maintenance Management Effectiveness of Public Hospital Building

    Directory of Open Access Journals (Sweden)

    Farhana Omar Mardhiah

    2017-01-01

    Full Text Available Effectiveness of management in maintenance aspect holds the key element in influencing the performance of overall maintenance management. Similarly, public hospital building needs an effective maintenance management as this type of building in nature is one of the most complex issues in the field of maintenance. Improper building maintenance management adopted by the organization significantly will interrupt the overall operation of the building. Therefore, this paper is aim to identifying the key performance indicator (KPI of effectiveness of maintenance management for the public hospital building. A total of 32 set of questionnaires were distributed to the maintenance manager for each hospital in the northern region of peninsular Malaysia by using self-administration strategy. The survey answer was analyzed by performing descriptive analysis in SPSS. Overall, the result of descriptive analysis shows that all the ten factors of effectiveness of maintenance management are accepted as KPI since the mean value is at least 3.93 which classified as important and significant. The most significant factor of effectiveness of maintenance management is task planning and scheduling with the mean score of 4.35. While less significant factor is identify as maintenance approach with the value of mean score is 3.93. The both results indicates that the management need to have well-structured planning for the maintenance works and also need to embrace the exact strategy of maintenance approach in order to achieved better overall performance of maintenance management. This study may draw a standard practice for the government in assessing the performance of public facilities in terms of maintenance management.

  10. Environmental cleaning and disinfection.

    Science.gov (United States)

    Traverse, Michelle; Aceto, Helen

    2015-03-01

    The guidelines in this article provide veterinarians, veterinary technicians, and veterinary health care workers with an overview of evidence-based recommendations for the best practices associated with environmental cleaning and disinfection of a veterinary clinic that deals with small animals. Hospital-associated infections and the control and prevention programs necessary to alleviate them are addressed from an environmental perspective. Measures of hospital cleaning and disinfection include understanding mechanisms and types of contamination in veterinary settings, recognizing areas of potential concern, addressing appropriate decontamination techniques and selection of disinfectants, the management of potentially contaminated equipment, laundry, and waste management, and environmental surveillance strategies. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Modelling heavy metals build-up on urban road surfaces for effective stormwater reuse strategy implementation

    International Nuclear Information System (INIS)

    Hong, Nian; Zhu, Panfeng; Liu, An

    2017-01-01

    Urban road stormwater is an alternative water resource to mitigate water shortage issues in the worldwide. Heavy metals deposited (build-up) on urban road surface can enter road stormwater runoff, undermining stormwater reuse safety. As heavy metal build-up loads perform high variabilities in terms of spatial distribution and is strongly influenced by surrounding land uses, it is essential to develop an approach to identify hot-spots where stormwater runoff could include high heavy metal concentrations and hence cannot be reused if it is not properly treated. This study developed a robust modelling approach to estimating heavy metal build-up loads on urban roads using land use fractions (representing percentages of land uses within a given area) by an artificial neural network (ANN) model technique. Based on the modelling results, a series of heavy metal load spatial distribution maps and a comprehensive ecological risk map were generated. These maps provided a visualization platform to identify priority areas where the stormwater can be safely reused. Additionally, these maps can be utilized as an urban land use planning tool in the context of effective stormwater reuse strategy implementation. - Highlights: • A model was developed to simulate heavy metal build-up loads on urban roads. • This model is based on artificial neural networks. • Land use fractions was used to model build-up loads on different particle sizes. • The maps of heavy metal spatial distribution and ecological risk were generated. • This model can be used for effective stormwater reuse strategy implementation. - Development of a robust modelling approach to mapping heavy metals build-up and their ecological risks for stormwater reuse safety.

  12. Effectiveness of biosecurity measures in preventing badger visits to farm buildings.

    Science.gov (United States)

    Judge, Johanna; McDonald, Robbie A; Walker, Neil; Delahay, Richard J

    2011-01-01

    Bovine tuberculosis caused by Mycobacterium bovis is a serious and economically important disease of cattle. Badgers have been implicated in the transmission and maintenance of the disease in the UK since the 1970s. Recent studies have provided substantial evidence of widespread and frequent visits by badgers to farm buildings during which there is the potential for close direct contact with cattle and contamination of cattle feed. Here we evaluated the effectiveness of simple exclusion measures in improving farm biosecurity and preventing badger visits to farm buildings. In the first phase of the study, 32 farms were surveyed using motion-triggered infrared cameras on potential entrances to farm buildings to determine the background level of badger visits experienced by each farm. In the second phase, they were divided into four treatment groups; "Control", "Feed Storage", "Cattle Housing" and "Both", whereby no exclusion measures were installed, exclusion measures were installed on feed storage areas only, cattle housing only or both feed storage and cattle housing, respectively. Badger exclusion measures included sheet metal gates, adjustable metal panels for gates, sheet metal fencing, feed bins and electric fencing. Cameras were deployed for at least 365 nights in each phase on each farm. Badger visits to farm buildings occurred on 19 of the 32 farms in phase one. In phase two, the simple exclusion measures were 100% effective in preventing badger entry into farm buildings, as long as they were appropriately deployed. Furthermore, the installation of exclusion measures also reduced the level of badger visits to the rest of the farmyard. The findings of the present study clearly demonstrate how relatively simple practical measures can substantially reduce the likelihood of badger visits to buildings and reduce some of the potential for contact and disease transmission between badgers and cattle.

  13. Effectiveness of biosecurity measures in preventing badger visits to farm buildings.

    Directory of Open Access Journals (Sweden)

    Johanna Judge

    Full Text Available BACKGROUND: Bovine tuberculosis caused by Mycobacterium bovis is a serious and economically important disease of cattle. Badgers have been implicated in the transmission and maintenance of the disease in the UK since the 1970s. Recent studies have provided substantial evidence of widespread and frequent visits by badgers to farm buildings during which there is the potential for close direct contact with cattle and contamination of cattle feed. METHODOLOGY: Here we evaluated the effectiveness of simple exclusion measures in improving farm biosecurity and preventing badger visits to farm buildings. In the first phase of the study, 32 farms were surveyed using motion-triggered infrared cameras on potential entrances to farm buildings to determine the background level of badger visits experienced by each farm. In the second phase, they were divided into four treatment groups; "Control", "Feed Storage", "Cattle Housing" and "Both", whereby no exclusion measures were installed, exclusion measures were installed on feed storage areas only, cattle housing only or both feed storage and cattle housing, respectively. Badger exclusion measures included sheet metal gates, adjustable metal panels for gates, sheet metal fencing, feed bins and electric fencing. Cameras were deployed for at least 365 nights in each phase on each farm. RESULTS: Badger visits to farm buildings occurred on 19 of the 32 farms in phase one. In phase two, the simple exclusion measures were 100% effective in preventing badger entry into farm buildings, as long as they were appropriately deployed. Furthermore, the installation of exclusion measures also reduced the level of badger visits to the rest of the farmyard. The findings of the present study clearly demonstrate how relatively simple practical measures can substantially reduce the likelihood of badger visits to buildings and reduce some of the potential for contact and disease transmission between badgers and cattle.

  14. Effect of highly reflective roofing sheet on building thermal loads for a school in Osaka

    Directory of Open Access Journals (Sweden)

    Yuan Jihui

    2017-01-01

    Full Text Available Currently, urban heat island (UHI phenomenon and building energy consumptions are becoming serious. Strategies to mitigate UHI and reduce building energy consumptions are implemented worldwide. In Japan, as an effective means of mitigating UHI and saving energy of buildings, highly reflective (HR and green roofs are increasingly used. In order to evaluate the effect of roofs with high reflection and thermal insulation on the energy conservation of buildings, we investigated the roof solar reflectivity of the subject school in Osaka, in which the HR roofing sheet was installed on the roof from 2010. Thermal loads, including cooling and heating loads of the top floor of school, were calculated using the thermal load calculation software, New HASP/ACLD-β. Comparing the thermal loads after HR roofing sheet installation to previous, the annual thermal load decreased about 25 MJ/m2-year and the cooling load decreased about 112 MJ/m2-year. However, the heating load increased about 87 MJ/m2-year in winter. To minimize the annual thermal load, thermal insulation of the roof was also considered be used together with HR roofing sheet in this study. The results showed that the combination of HR roofing sheet and high thermal insulation is more effective to reduce the annual thermal load.

  15. How much information disclosure of building energy performance is necessary?

    International Nuclear Information System (INIS)

    Hsu, David

    2014-01-01

    Many different governments have begun to require disclosure of building energy performance, in order to allow owners and prospective buyers to incorporate this information into their investment decisions. These policies, known as disclosure or information policies, require owners to benchmark their buildings and sometimes conduct engineering audits. However, given substantial variation in the cost to disclose different types of information, it is natural to ask: how much and what kind of information about building energy performance should be disclosed, and for what purposes? To answer this question, this paper assembles and cleans a comprehensive panel dataset of New York City multifamily buildings, and analyzes its predictive power using a Bayesian multilevel regression model. Analysis of variance (ANOVA) reveals that building-level variation is the most important factor in explaining building energy use, and that there are few, if any, relationships of building systems to observed energy use. This indicates that disclosure laws requiring benchmarking data may be relatively more useful than engineering audits in explaining the observed energy performance of existing buildings. These results should inform the further development of information disclosure laws. - Highlights: • A comprehensive panel dataset of energy performance and building characteristics was assembled and cleaned. • The effectiveness of the disclosed information to predict building energy performance was tested using a regression model. • Building-level variation has a greater effect than any building characteristic or systems. • Benchmarking data alone predicts energy performance equally as well as both benchmarking and engineering audit data together, and better than audit data alone

  16. Sonochemical cleaning efficiencies in dental instruments

    Science.gov (United States)

    Tiong, T. Joyce; Walmsley, A. Damien; Price, Gareth J.

    2012-05-01

    Ultrasound has been widely used for cleaning purposes in a variety of situations, including in dental practice. Cleaning is achieved through a combination of acoustically driven streaming effects and sonochemical effects arising from the production of inertial cavitation in a liquid. In our work, various dental instruments used for endodontic (root canal) treatment have been evaluated for their efficiency in producing sonochemical effects in an in-vitro cleaning environment. The areas where cavitation was produced were mapped by monitoring chemiluminescence from luminol solutions and this was correlated with their cleaning efficiencies - assessed by the ability to bleach a dye, to form an emulsion by mixing immiscible components and also to remove ink from a glass surface. The results showed good correlation (Pearson's coefficient > 0.9) between the cavitation and cleaning efficiencies, suggesting that the former plays an important role in cleaning. The methods developed and the results will be beneficial in endodontics research in order to optimise future root canal instruments and treatments.

  17. Systematic review and meta-analysis of the effectiveness of antiseptic agents for meatal cleaning in the prevention of catheter-associated urinary tract infections.

    Science.gov (United States)

    Fasugba, O; Koerner, J; Mitchell, B G; Gardner, A

    2017-03-01

    Catheter-associated urinary tract infections (CAUTIs) are among the most common healthcare-associated infections. Antiseptic cleaning of the meatal area before and during catheter use may reduce the risk of CAUTIs. To undertake a systematic review of the literature and meta-analysis of studies investigating the effectiveness of antiseptic cleaning before urinary catheter insertion and during catheter use for prevention of CAUTIs. Electronic databases were searched to identify randomized controlled trials. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated and compared across intervention and control groups using DerSimonian-Laird random-effects model. Subgroup analyses were performed. Heterogeneity was estimated using the I 2 statistic. In total, 2665 potential papers were identified; of these, 14 studies were eligible for inclusion. There was no difference in the incidence of CAUTIs when comparing antiseptic and non-antiseptic agents (pooled OR 0.90, 95% CI 0.73-1.10; P=0.31), or when comparing different agents: povidone-iodine vs routine care; povidone-iodine vs soap and water; chlorhexidine vs water; povidone-iodine vs saline; povidone-iodine vs water; and green soap and water vs routine care (P>0.05 for all). Comparison of an antibacterial agent with routine care indicated near significance (P=0.06). There was no evidence of heterogeneity (I 2 =0%; P>0.05). Subgroup analyses showed no difference in the incidence of CAUTIs in terms of country, setting, risk of bias, sex and frequency of administration. There were no differences in CAUTI rates, although methodological issues hamper generalizability of this finding. Antibacterial agents may prove to be significant in a well-conducted study. The present results provide good evidence to inform infection control guidelines in catheter management. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Effects of Reducing Antimicrobial Use and Applying a Cleaning and Disinfection Program in Veal Calf Farming: Experiences from an Intervention Study to Control Livestock-Associated MRSA.

    Directory of Open Access Journals (Sweden)

    Alejandro Dorado-García

    Full Text Available With the ultimate aim of containing the emergence of resistant bacteria, a Dutch policy was set in place in 2010 promoting a reduction of antimicrobial use (AMU in food-producing animals. In this context, a study evaluated strategies to curb livestock-associated methicillin resistant Staphylococcus aureus (LA-MRSA. Fifty-one veal calf farms were assigned to one of 3 study arms: RAB farms reducing antimicrobials by protocol; RAB-CD farms reducing antimicrobials by protocol and applying a cleaning and disinfection program; and Control farms without interventions. MRSA carriage was tested in week 0 and week 12 of 2 consecutive production cycles in farmers, family members and veal calves. Interventions were validated and a cyclic rise in MRSA-prevalence in animals was shown with a more moderate increase in RAB farms. Prevalence in humans declined parallel over time in the study arms but RAB farms were at the lowest MRSA levels from the beginning of the study. In RAB-CD farms, human and animal prevalence did not differ from Control farms and MRSA air loads were significantly higher than in the other study arms. Mimicking the national trend, an overall AMU decrease (daily dosages per animal per cycle (DDDA/C was observed over 4 pre-study and the 2 study cycles; this trend did not have a significant effect on a set of evaluated farm technical parameters. AMU was positively associated with MRSA across study arms (ORs per 10 DDDA/C increase = 1.26 for both humans (p = 0.07 and animals (p = 0.12 in first cycle. These results suggest that AMU reduction might be a good strategy for curbing MRSA in veal calf farming, however the specific cleaning and disinfecting program in RAB-CD farms was not effective. The drop in MRSA prevalence in people during the study could be attributed to the observed long-term AMU decreasing trend.

  19. Effects of Reducing Antimicrobial Use and Applying a Cleaning and Disinfection Program in Veal Calf Farming: Experiences from an Intervention Study to Control Livestock-Associated MRSA.

    Science.gov (United States)

    Dorado-García, Alejandro; Graveland, Haitske; Bos, Marian E H; Verstappen, Koen M; Van Cleef, Brigitte A G L; Kluytmans, Jan A J W; Wagenaar, Jaap A; Heederik, Dick J J

    2015-01-01

    With the ultimate aim of containing the emergence of resistant bacteria, a Dutch policy was set in place in 2010 promoting a reduction of antimicrobial use (AMU) in food-producing animals. In this context, a study evaluated strategies to curb livestock-associated methicillin resistant Staphylococcus aureus (LA-MRSA). Fifty-one veal calf farms were assigned to one of 3 study arms: RAB farms reducing antimicrobials by protocol; RAB-CD farms reducing antimicrobials by protocol and applying a cleaning and disinfection program; and Control farms without interventions. MRSA carriage was tested in week 0 and week 12 of 2 consecutive production cycles in farmers, family members and veal calves. Interventions were validated and a cyclic rise in MRSA-prevalence in animals was shown with a more moderate increase in RAB farms. Prevalence in humans declined parallel over time in the study arms but RAB farms were at the lowest MRSA levels from the beginning of the study. In RAB-CD farms, human and animal prevalence did not differ from Control farms and MRSA air loads were significantly higher than in the other study arms. Mimicking the national trend, an overall AMU decrease (daily dosages per animal per cycle (DDDA/C)) was observed over 4 pre-study and the 2 study cycles; this trend did not have a significant effect on a set of evaluated farm technical parameters. AMU was positively associated with MRSA across study arms (ORs per 10 DDDA/C increase = 1.26 for both humans (p = 0.07) and animals (p = 0.12 in first cycle)). These results suggest that AMU reduction might be a good strategy for curbing MRSA in veal calf farming, however the specific cleaning and disinfecting program in RAB-CD farms was not effective. The drop in MRSA prevalence in people during the study could be attributed to the observed long-term AMU decreasing trend.

  20. Cleaning of spent solvent and method of processing cleaning liquid waste

    International Nuclear Information System (INIS)

    Ozawa, Masaki; Kawada, Tomio; Tamura, Nobuhiko.

    1993-01-01

    Spent solvents discharged from a solvent extracting step mainly comprise n-dodecane and TBP and contain nuclear fission products and solvent degradation products. The spent solvents are cleaned by using a sodium chloride free detergent comprising hydrazine oxalate and hydrazine carbonate in a solvent cleaning device. Nitric acid is added to the cleaning liquid wastes containing spent detergents extracted from the solvent cleaning device, to control an acid concentration. The detergent liquid wastes of controlled acid concentration are sent to an electrolysis oxidation bath as electrolytes and electrochemically decomposed in carbonic acid gas, nitrogen gas and hydrogen gas. The decomposed gases are processed as off gases. The decomposed liquid wastes are processed as a waste nitric acid solution. This can provide more effective cleaning. In addition, the spent detergent can be easily decomposed in a room temperature region. Accordingly, the amount of wastes can be decreased. (I.N.)

  1. Effectiveness of E-Learning for Students Vocational High School Building Engineering Program

    Science.gov (United States)

    Soeparno; Muslim, Supari

    2018-04-01

    Implementation of vocational learning in accordance with the 2013 curriculum must meet the criteria, one of which is learning to be consistent with advances in technology and information. Technology-based learning in vocational commonly referred to as E-Learning, online (in the network) and WBL (Web-Based Learning). Facts on the ground indicate that based learning technology and information on Vocational High School of Building Engineering is still not going well. The purpose of this research is to know: advantages and disadvantages of learning with E-Learning, conformity of learning with E-Learning with characteristics of students on Vocational High School of Building Engineering and effective learning method based on E-Learning for students on Vocational High School of Building Engineering. Research done by literature method, get the following conclusion as follow: the advantages of E-Learning is learning can be done anywhere and anytime, efficient in accessing materials and tasks, ease of communication and discussion; while the shortage is the need for additional costs for good internet access and lack of social interaction between teachers and students. E-learning is appropriate to basic knowledge competencies, and not appropriate at the level of advanced competencies and skills. Effective E-Learning Based Learning Method on Vocational High School of Building Engineering is a Blended method that is a mix between conventional method and e-learning.

  2. Laser-assisted cleaning

    Indian Academy of Sciences (India)

    Experiments conducted with loose contamination on metal and transparent dielectric surfaces proved conclusively the dominant role played by the absorption of the incident radiation by the surface towards the generation of the cleaning force as against the absorption in the particulates alone. Further, the presence of ...

  3. Road-Cleaning Device

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    Roadways are literally soaked with petrochemical byproducts, oils, gasoline, and other volatile substances that eventually run off into sewers and end up in rivers, waterways, and other undesirable places. Can the roads be cleaned of these wastes, with their proper disposal? Can vehicles, robots, or other devices be designed that could be driven…

  4. Clean energy microgrids

    CERN Document Server

    Obara, Shin'ya

    2017-01-01

    This book describes the latest technology in microgrids and economic, environmental and policy aspects of their implementation, including microgrids for cold regions, and future trends. The aim of this work is to give this complete overview of the latest technology around the world, and the interrelation with clean energy systems.

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  6. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  8. No positive effect of Acid etching or plasma cleaning on osseointegration of titanium implants in a canine femoral condyle press-fit model

    DEFF Research Database (Denmark)

    Saksø, Henrik; Jakobsen, Thomas Vestergaard; Mortensen, Mikkel Saksø

    2013-01-01

    Implant surface treatments that improve early osseointegration may prove useful in long-term survival of uncemented implants. We investigated Acid Etching and Plasma Cleaning on titanium implants.......Implant surface treatments that improve early osseointegration may prove useful in long-term survival of uncemented implants. We investigated Acid Etching and Plasma Cleaning on titanium implants....

  9. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  10. Fiscal 2000 achievement report on the development of energy conservation/environment purification system using cleaning effect of optical irradiation; 2000 nendo hikari clean gijutsu wo mochiita sho energy kankyo joka system no kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The research aims to develop materials and apparatuses for the purification of atmosphere using titanium dioxide that exhibits a powerful oxidizing capability when irradiated with light. A study is conducted to find out an optimum composition for a photocatalytic fluorocarbon polymer sheet suitable for use in a denitration apparatus. A high density fluorocarbon polymer sheet composed of TiO{sub 2} modified with 0.3% of Pd/absorbent zeolite/fluorocarbon polymer PTFE (polytetrafluoroethylene) =48-63/24-36/10-20 is found to show high denitration efficiency, and this achieves the denitration efficiency goal. As for sheet thickness, 0.75mm is found to be enough. The sheet experiences some hardening in an accelerated exposure test, but does not change much in a surface gloss test or a chalking test. Although a slight reduction is observed in denitration efficiency, yet the durability goal is achieved. In the effort to develop an energy conservation type air cleaning apparatus, field tests and experiments are repeatedly conducted. As for photodenitration in the cleaning apparatus, the number of photodenitration stages and the magnitude of equimolar adsorption area necessary for achieving an 80% denitration rate is calculated from the relations of the NOx concentration profile and the denitration rate in the equimolar adsorption module to (gas flow rate/module surface), and the result shows that the initially intended goal is achieved. (NEDO)

  11. EFFECT OF RECYCLE TIRE ISOLATOR AS EARTHQUAKE RESISTANCE SYSTEM FOR LOW RISE BUILDINGS IN MALAYSIA

    Directory of Open Access Journals (Sweden)

    SOW WEI JIE

    2016-08-01

    Full Text Available The purpose of this research is to investigate the effect of Recycle Tire Isolator (RTI as earthquake resistance system for low rise buildings in Malaysia. Most of the earthquake’s victims are due to the collapse of poorly designed concrete and masonry buildings. Therefore, an economical but reliable RTI is introduced to solve the problem in most of the developing countries such as Malaysia. This study focuses on the effect of RTI-5 (5 layers RTI in protecting three stories buildings. The vertical displacement of RTI-5 was determined through static compression test. The maximum vertical displacement of RTI-5 was obtained when the specimen was monotonically loaded to failure. Finite element analysis was carried out by using ANSYS V16.0 to model the RTI-5 and the results obtained were compared to the experimental results. The dynamic stiffness and damping ratio of RTI-5 were investigated through dynamic test. The behaviour of various thickness of RTI were examined and compared with Rubber Bearing (RB and Scrap Tire Rubber Pad (STRP.Total displacement of three stories buildings on fixed base and on base isolation were determined. The results from static compression test and finite element analysis showed that RTI-5 could sustain a vertical load of 380 kN with vertical deformation of 12.5 mm. It has been verified by finite element analysis (FEA where both of the results achieved close agreement in terms of vertical deformation. RTI-5 and STRP have similar vertical stiffness due to the employment of same material in fabrication. However, rubber bearing is stiffer than RTI-5 due to the present of embedded steel plates. Besides, RTI-4 is stiffer than RTI-5 due to the number of layers are lesser in RTI-4. The results of dynamic test shown that RTI-5 has higher damping ratio than RTI-4. In overall, total deformation at the top floor of the three stories building is reduced by 83% via implementation of RTI in the base of the building. It has been proven

  12. Washing away your sins in the brain: physical cleaning and priming of cleaning recruit different brain networks after moral threat.

    Science.gov (United States)

    Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin; Liu, Chao

    2017-07-01

    The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. © The Author (2017). Published by Oxford University Press.

  13. Challenges and Strategies for Building and Maintaining Effective Preceptor-Preceptee Relationships among Nurses

    Directory of Open Access Journals (Sweden)

    Gerald A. Matua

    2014-10-01

    Full Text Available Objectives: This study aimed to determine the challenges encountered and strategies used by nurse preceptors to build effective professional relationships during the preceptorship of final year nursing students. Methods: This study was conducted in November 2012 at the College of Nursing in Sultan Qaboos University, Muscat, Oman. A qualitative research design consisting of focus group discussions was used to investigate the challenges that preceptors encounter and the strategies that they use to build effective relationships with preceptees. A total of 21 preceptors from Sultan Qaboos University Hospital participated in the study as part of a training workshop for nurse preceptors. The interviews were audio recorded, transcribed verbatim and thematically analysed. Results: The main challenges faced by preceptors included discrepancies in applying theory to practice; lack of trust; lack of time, and perceived lack of knowledge. The effective strategies identified by the preceptors to be used in building a healthy preceptor-preceptee relationship were proper orientation; effective communication; preparation for complex situations; appreciation and acknowledgment; positive feedback; assurance of support; spending time together; knowing preceptors personally; giving breaks, and encouraging self-commitment. Conclusion: Preceptors should be encouraged to identify challenges that hinder the building of effective relationships with preceptees early during their preceptorship. The incorporation of appropriate and evidenced-based strategies, such as those identified in this study, can transform the preceptorship experience into one that is fulfilling for both preceptors and preceptees. This may lead to greater job satisfaction, personal and professional growth as well as higher self-esteem levels for preceptors and the realisation of clinical objectives for preceptees.

  14. Challenges and Strategies for Building and Maintaining Effective Preceptor-Preceptee Relationships among Nurses.

    Science.gov (United States)

    Matua, Gerald A; Seshan, Vidya; Savithri, Raman; Fronda, Dennis C

    2014-11-01

    This study aimed to determine the challenges encountered and strategies used by nurse preceptors to build effective professional relationships during the preceptorship of final year nursing students. This study was conducted in November 2012 at the College of Nursing in Sultan Qaboos University, Muscat, Oman. A qualitative research design consisting of focus group discussions was used to investigate the challenges that preceptors encounter and the strategies that they use to build effective relationships with preceptees. A total of 21 preceptors from Sultan Qaboos University Hospital participated in the study as part of a training workshop for nurse preceptors. The interviews were audio recorded, transcribed verbatim and thematically analysed. The main challenges faced by preceptors included discrepancies in applying theory to practice; lack of trust; lack of time, and perceived lack of knowledge. The effective strategies identified by the preceptors to be used in building a healthy preceptor-preceptee relationship were proper orientation; effective communication; preparation for complex situations; appreciation and acknowledgment; positive feedback; assurance of support; spending time together; knowing preceptors personally; giving breaks, and encouraging self-commitment. Preceptors should be encouraged to identify challenges that hinder the building of effective relationships with preceptees early during their preceptorship. The incorporation of appropriate and evidenced-based strategies, such as those identified in this study, can transform the preceptorship experience into one that is fulfilling for both preceptors and preceptees. This may lead to greater job satisfaction, personal and professional growth as well as higher self-esteem levels for preceptors and the realisation of clinical objectives for preceptees.

  15. Urban weather data and building models for the inclusion of the urban heat island effect in building performance simulation

    Directory of Open Access Journals (Sweden)

    M. Palme

    2017-10-01

    Full Text Available This data article presents files supporting calculation for urban heat island (UHI inclusion in building performance simulation (BPS. Methodology is used in the research article “From urban climate to energy consumption. Enhancing building performance simulation by including the urban heat island effect” (Palme et al., 2017 [1]. In this research, a Geographical Information System (GIS study is done in order to statistically represent the most important urban scenarios of four South-American cities (Guayaquil, Lima, Antofagasta and Valparaíso. Then, a Principal Component Analysis (PCA is done to obtain reference Urban Tissues Categories (UTC to be used in urban weather simulation. The urban weather files are generated by using the Urban Weather Generator (UWG software (version 4.1 beta. Finally, BPS is run out with the Transient System Simulation (TRNSYS software (version 17. In this data paper, four sets of data are presented: 1 PCA data (excel to explain how to group different urban samples in representative UTC; 2 UWG data (text to reproduce the Urban Weather Generation for the UTC used in the four cities (4 UTC in Lima, Guayaquil, Antofagasta and 5 UTC in Valparaíso; 3 weather data (text with the resulting rural and urban weather; 4 BPS models (text data containing the TRNSYS models (four building models.

  16. Effect of thermal mass on life cycle primary energy balances of a concrete- and a wood-frame building

    International Nuclear Information System (INIS)

    Dodoo, Ambrose; Gustavsson, Leif; Sathre, Roger

    2012-01-01

    Highlights: ► The effect of thermal mass on life cycle primary energy balance of concrete and wood building is analyzed. ► A concrete building has slightly lower space heating demand than a wood alternative. ► Still, a wood building has a lower life cycle primary energy use than a concrete alternative. ► The influence of thermal mass on space heating energy use for buildings in Nordic climate is small. -- Abstract: In this study we analyze the effect of thermal mass on space heating energy use and life cycle primary energy balances of a concrete- and a wood-frame building. The analysis includes primary energy use during the production, operation, and end-of-life phases. Based on hour-by-hour dynamic modeling of heat flows in building mass configurations we calculate the energy saving benefits of thermal mass during the operation phase of the buildings. Our results indicate that the energy savings due to thermal mass is small and varies with the climatic location and energy efficiency levels of the buildings. A concrete-frame building has slightly lower space heating demand than a wood-frame alternative, due to the higher thermal mass of concrete-based materials. Still, a wood-frame building has a lower life cycle primary energy balance than a concrete-frame alternative. This is due primarily to the lower production primary energy use and greater bioenergy recovery benefits of the wood-frame buildings. These advantages outweigh the energy saving benefits of thermal mass. We conclude that the influence of thermal mass on space heating energy use for buildings located in Nordic climate is small and that wood-frame buildings with cogeneration based district heating would be an effective means of reducing primary energy use in the built environment.

  17. Summer and Winter Effect of Innovative Cool Roof Tiles on the Dynamic Thermal Behavior of Buildings

    Directory of Open Access Journals (Sweden)

    Anna Laura Pisello

    2014-04-01

    Full Text Available Cool roofs represent an acknowledged passive cooling technique to reduce building energy consumption for cooling and to mitigate urban heat island effects. This paper concerns the evaluation of the dynamic effect of new cool roof clay tiles on building thermal performance in summer and winter conditions. To this end, these properties have been analyzed on traditional roof brick tiles through an indoor and outdoor two-year long continuous monitoring campaign set up in a residential building located in central Italy. The analysis and the cooperation with industrial companies producing brick tiles and reflective coatings allowed the production of a new tile with notable “cool roof” properties through the traditional industrial manufacturing path of such tiles. Notable results show that during summer the high reflection tiles are able to decrease the average external roof surface temperature by more than 10 °C and the indoor operative temperature by more than 3 °C. During winter the average external surface temperature is lower with high reflection tiles by about 1 °C. Singular optic-thermal phenomena are registered while evaluating the dynamics of the cool roof effect. Interesting findings show how the sloped cool roof application could suggest further considerations about the dynamic effect of cool roofs.

  18. Exploring surface cleaning strategies in hospital to prevent contact transmission of methicillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Lei, Hao; Jones, Rachael M; Li, Yuguo

    2017-01-18

    Cleaning of environmental surfaces in hospitals is important for the control of methicillin-resistant Staphylococcus aureus (MRSA) and other hospital-acquired infections transmitted by the contact route. Guidance regarding the best approaches for cleaning, however, is limited. In this study, a mathematical model based on ordinary differential equations was constructed to study MRSA concentration dynamics on high-touch and low-touch surfaces, and on the hands and noses of two patients (in two hospitals rooms) and a health care worker in a hypothetical hospital environment. Two cleaning interventions - whole room cleaning and wipe cleaning of touched surfaces - were considered. The performance of the cleaning interventions was indicated by a reduction in MRSA on the nose of a susceptible patient, relative to no intervention. Whole room cleaning just before first patient care activities of the day was more effective than whole room cleaning at other times, but even with 100% efficiency, whole room cleaning only reduced the number of MRSA transmitted to the susceptible patient by 54%. Frequent wipe cleaning of touched surfaces was shown to be more effective that whole room cleaning because surfaces are rapidly re-contaminated with MRSA after cleaning. Wipe cleaning high-touch surfaces was more effective than wipe cleaning low-touch surfaces for the same frequency of cleaning. For low wipe cleaning frequency (≤3 times per hour), high-touch surfaces should be targeted, but for high wipe cleaning frequency (>3 times per hour), cleaning should target high- and low-touch surfaces in proportion to the surface touch frequency. This study reproduces the observations from a field study of room cleaning, which provides support for the validity of our findings. Daily whole room cleaning, even with 100% cleaning efficiency, provides limited reduction in the number of MRSA transmitted to susceptible patients via the contact route; and should be supplemented with frequent targeted

  19. Clean Energy Solutions Center: Assisting Countries with Clean Energy Policy

    Science.gov (United States)

    advice on financing instruments. In a recent keynote to the Climate and Clean Energy Investment Forum renewable energy technologies in the country. Informing Energy Access and Clean Energy Project Finance understanding and knowledge of how to design policies that enable financing and encourage investment in clean

  20. The effectiveness of energy management system on energy efficiency in the building

    Science.gov (United States)

    Julaihi, F.; Ibrahim, S. H.; Baharun, A.; Affendi, R.; Nawi, M. N. M.

    2017-10-01

    Energy plays a key role in achieving the desired economic growth for the country. Worldwide industries use 40 percent energy for material and consumption protection to fulfil human needs which contributes almost 37 percent of global greenhouse gases emissions. One of the approach in order to reduce the emission of greenhouse gases to the environment is by conserving energy. This could be executed by implementing energy management especially in commercial and office buildings as daily electricity consumption is high in this type of building. Energy management can also increase the efficiency of energy in the building. Study has been conducted to investigate the performance on implementation of energy management system in office building. Energy management is one of the contemporary challenges, thus study adopts an exploratory approach by using a tool developed by UNIDO called EnMS or Energy Management System. Findings show that by implementing energy management can reduce electricity consumption up to 30%. However, serious initiatives by the organization are needed to promote the effectiveness of energy management.

  1. The effect of building regulations and energy conservation measures in domestic sector on national energy consumption

    International Nuclear Information System (INIS)

    Samo, S.R.; Akhund, M.A.; Brohi, K.M.

    2004-01-01

    In England, housing accounts for some 30% of total fuel consumption and a similar proportion of energy-related carbon dioxide (CO/sub 2/) emission. A study has been conducted to analyse the effect of the legislations and UK thermal building regulations on national energy consumption in housing. This research paper presents data on the percentage of dwelling stock, the energy consumption, energy cost and carbon dioxide (CO/sub 2/) emission in different types of dwellings, which comply different building regulations from 1965 to 1995. It was found that. 66% of the dwelling stock, which comply the building Regulations before 1965, consumes 73% of total energy used in housing. This dwelling stock is also responsible for 75% of carbon dioxide (CO/sub 2/) emission. Whereas currently only 4% of the dwelling stock complies the latest building regulations 1995 which consume 2 % of energy and produce a similar percentage of carbon dioxide (CO/sub 2/) emission in housing. Since the large portion of the dwelling stock is comprised of old dwellings, therefore the greatest potential for energy conservation measures can be found in improving these dwellings instead of constructing new dwellings. (author)

  2. Drag of Clean and Fouled Net Panels--Measurements and Parameterization of Fouling.

    Directory of Open Access Journals (Sweden)

    Lars Christian Gansel

    Full Text Available Biofouling is a serious problem in marine aquaculture and it has a number of negative impacts including increased forces on aquaculture structures and reduced water exchange across nets. This in turn affects the behavior of fish cages in waves and currents and has an impact on the water volume and quality inside net pens. Even though these negative effects are acknowledged by the research community and governmental institutions, there is limited knowledge about fouling related effects on the flow past nets, and more detailed investigations distinguishing between different fouling types have been called for. This study evaluates the effect of hydroids, an important fouling organism in Norwegian aquaculture, on the forces acting on net panels. Drag forces on clean and fouled nets were measured in a flume tank, and net solidity including effect of fouling were determined using image analysis. The relationship between net solidity and drag was assessed, and it was found that a solidity increase due to hydroids caused less additional drag than a similar increase caused by change in clean net parameters. For solidities tested in this study, the difference in drag force increase could be as high as 43% between fouled and clean nets with same solidity. The relationship between solidity and drag force is well described by exponential functions for clean as well as for fouled nets. A method is proposed to parameterize the effect of fouling in terms of an increase in net solidity. This allows existing numerical methods developed for clean nets to be used to model the effects of biofouling on nets. Measurements with other types of fouling can be added to build a database on effects of the accumulation of different fouling organisms on aquaculture nets.

  3. Assessment of Effective Prestressed Force of Nuclear Containment Building using SI Technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H. P.; Jang, J. B.; Hwang, K. M.; Song, Y. C. [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Bonded tendons have been used in reactor buildings of heavy water reactors and the light water reactors of some nuclear power plants operating in Korea. The assessment of prestressed forces on those bonded tendons is becoming an important issue in assuring their continuous operation beyond their design life. In order to assess the effective prestressed force on the bonded tendon, indirect assessment techniques have been applying to the test beams which were manufactured on construction time. Therefore, this research mainly forced to establish the assessment methodology to measure directly the effective prestressed force on the bonded tendon of containment buildings using System Identification (SI) technique. To accomplish this purpose, simple SI method was proposed and adapted three dimensional finite element analysis of the 1:4 scale prestressed concrete containment vessel (PCCV) tested by Sandia National Laboratory in 2000

  4. Plasma cleaning for waste minimization

    Energy Technology Data Exchange (ETDEWEB)

    Ward, P.P.

    1993-07-01

    Although plasma cleaning is a recognized substitute for solvent cleaning in removing organic contaminants, some universal problems in plasma cleaning processes prevent wider use of plasma techniques. Lack of understanding of the fundamental mechanisms of the process, unreliable endpoint detection techniques, and slow process times make plasma cleaning processes less than desirable. Our approach to address these plasma cleaning problems is described. A comparison of plasma cleaning rates of oxygen and oxygen/sulfur hexafluoride gases shows that fluorine-containing plasmas can enhance etch rates by 400% over oxygen alone. A discussion of various endpoint indication techniques is discussed and compared for application suitability. Work toward a plasma cleaning database is discussed. In addition to the global problems of plasma cleaning, an experiment where the specific mixed-waste problem of removal of machine oils from radioactive scrap metal is discussed.

  5. Clean Energy Solutions Center Services

    Energy Technology Data Exchange (ETDEWEB)

    2016-03-01

    The Solutions Center offers no-cost expert policy assistance, webinars and training forums, clean energy policy reports, data, and tools provided in partnership with more than 35 leading international and regional clean energy organizations.

  6. Automated cleaning of electronic components

    International Nuclear Information System (INIS)

    Drotning, W.; Meirans, L.; Wapman, W.; Hwang, Y.; Koenig, L.; Petterson, B.

    1994-01-01

    Environmental and operator safety concerns are leading to the elimination of trichloroethylene and chlorofluorocarbon solvents in cleaning processes that remove rosin flux, organic and inorganic contamination, and particulates from electronic components. Present processes depend heavily on these solvents for manual spray cleaning of small components and subassemblies. Use of alternative solvent systems can lead to longer processing times and reduced quality. Automated spray cleaning can improve the quality of the cleaning process, thus enabling the productive use of environmentally conscious materials, while minimizing personnel exposure to hazardous materials. We describe the development of a prototype robotic system for cleaning electronic components in a spray cleaning workcell. An important feature of the prototype system is the capability to generate the robot paths and motions automatically from the CAD models of the part to be cleaned, and to embed cleaning process knowledge into the automatically programmed operations

  7. Challenges and Strategies for Building and Maintaining Effective Preceptor-Preceptee Relationships among Nurses

    OpenAIRE

    Matua, Gerald A.; Seshan, Vidya; Savithri, Raman; Fronda, Dennis C.

    2014-01-01

    Objectives: This study aimed to determine the challenges encountered and strategies used by nurse preceptors to build effective professional relationships during the preceptorship of final year nursing students. Methods: This study was conducted in November 2012 at the College of Nursing in Sultan Qaboos University, Muscat, Oman. A qualitative research design consisting of focus group discussions was used to investigate the challenges that preceptors encounter and the strategies that they use...

  8. Effective Energy Simulation and Optimal Design of Side-lit Buildings with Venetian Blinds

    Science.gov (United States)

    Cheng, Tian

    Venetian blinds are popularly used in buildings to control the amount of incoming daylight for improving visual comfort and reducing heat gains in air-conditioning systems. Studies have shown that the proper design and operation of window systems could result in significant energy savings in both lighting and cooling. However, there is no convenient computer tool that allows effective and efficient optimization of the envelope of side-lit buildings with blinds now. Three computer tools, Adeline, DOE2 and EnergyPlus widely used for the above-mentioned purpose have been experimentally examined in this study. Results indicate that the two former tools give unacceptable accuracy due to unrealistic assumptions adopted while the last one may generate large errors in certain conditions. Moreover, current computer tools have to conduct hourly energy simulations, which are not necessary for life-cycle energy analysis and optimal design, to provide annual cooling loads. This is not computationally efficient, particularly not suitable for optimal designing a building at initial stage because the impacts of many design variations and optional features have to be evaluated. A methodology is therefore developed for efficient and effective thermal and daylighting simulations and optimal design of buildings with blinds. Based on geometric optics and radiosity method, a mathematical model is developed to reasonably simulate the daylighting behaviors of venetian blinds. Indoor illuminance at any reference point can be directly and efficiently computed. They have been validated with both experiments and simulations with Radiance. Validation results show that indoor illuminances computed by the new models agree well with the measured data, and the accuracy provided by them is equivalent to that of Radiance. The computational efficiency of the new models is much higher than that of Radiance as well as EnergyPlus. Two new methods are developed for the thermal simulation of buildings. A

  9. Sustainable development with clean coal

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    This paper discusses the opportunities available with clean coal technologies. Applications include new power plants, retrofitting and repowering of existing power plants, steelmaking, cement making, paper manufacturing, cogeneration facilities, and district heating plants. An appendix describes the clean coal technologies. These include coal preparation (physical cleaning, low-rank upgrading, bituminous coal preparation); combustion technologies (fluidized-bed combustion and NOx control); post-combustion cleaning (particulate control, sulfur dioxide control, nitrogen oxide control); and conversion with the integrated gasification combined cycle.

  10. Determination of Cost-Effective Energy Efficiency Measures in Buildings with the Aid of Multiple Indices

    Directory of Open Access Journals (Sweden)

    Theodoros Zachariadis

    2018-01-01

    Full Text Available Energy refurbishments of buildings can substantially contribute to economy-wide energy efficiency improvements, leading to decarbonisation and additional sustainability benefits. Prioritising the most economically promising investments is not straightforward because apart from cost-effectiveness calculations, several real-world constraints have to be taken into account. This paper describes an approach to assess the economically viable energy efficiency potential in the building sector of the Mediterranean island of Cyprus, with a combination of detailed engineering modelling, cost-effectiveness calculations and real-world considerations of budgetary, technical, behavioural and market constraints. We examine diverse cost-effectiveness indices and come up with a proposal for prioritising specific energy investments such as the installation of heat pumps, insulation of roofs, and replacement of lighting and electronic equipment—without however ignoring other measures that may be economically less favourable but can realistically be implemented in a limited number of buildings. Finally we address the governance of energy efficiency policies, focusing on weaknesses of the current regulatory environment in Cyprus, which can be generalised for many other countries facing similar dilemmas.

  11. Investigations of some building materials for γ-rays shielding effectiveness

    Science.gov (United States)

    Mann, Kulwinder Singh; Kaur, Baljit; Sidhu, Gurdeep Singh; Kumar, Ajay

    2013-06-01

    For construction of residential and non-residential buildings bricks are used as building blocks. Bricks are made from mixtures of sand, clay, cement, fly ash, gypsum, red mud and lime. Shielding effectiveness of five soil samples and two fly ash samples have been investigated using some energy absorption parameters (Mass attenuation coefficients, mass energy absorption coefficients, KERMA (kinetic energy released per unit mass), HVL, equivalent atomic number and electron densities) firstly at 14 different energies from 81-1332 keV then extended to wide energy range 0.015-15 MeV. The soil sample with maximum shielding effectiveness has been used for making eight fly ash bricks [(Lime)0.15 (Gypsum)0.05 (Fly Ash)x (Soil)0.8-x, where values of x are from 0.4-0.7]. High Purity Germanium (HPGe) detector has been used for gamma-ray spectroscopy. The elemental compositions of samples were analysed using an energy dispersive X-ray fluorescence (EDXRF) spectrometer. The agreements of theoretical and experimental values of mass attenuation coefficient have been found to be quite satisfactory. It has been verified that common brick possess the maximum shielding effectiveness for wide energy range 0.015-15 MeV. The results have been shown graphically with some useful conclusions for making radiation safe buildings.

  12. Effects of build parameters on linear wear loss in plastic part produced by fused deposition modeling

    Science.gov (United States)

    Mohamed, Omar Ahmed; Masood, Syed Hasan; Bhowmik, Jahar Lal

    2017-07-01

    Fused Deposition Modeling (FDM) is one of the prominent additive manufacturing technologies for producing polymer products. FDM is a complex additive manufacturing process that can be influenced by many process conditions. The industrial demands required from the FDM process are increasing with higher level product functionality and properties. The functionality and performance of FDM manufactured parts are greatly influenced by the combination of many various FDM process parameters. Designers and researchers always pay attention to study the effects of FDM process parameters on different product functionalities and properties such as mechanical strength, surface quality, dimensional accuracy, build time and material consumption. However, very limited studies have been carried out to investigate and optimize the effect of FDM build parameters on wear performance. This study focuses on the effect of different build parameters on micro-structural and wear performance of FDM specimens using definitive screening design based quadratic model. This would reduce the cost and effort of additive manufacturing engineer to have a systematic approachto make decision among the manufacturing parameters to achieve the desired product quality.

  13. Canyon solvent cleaning

    International Nuclear Information System (INIS)

    Reif, D.J.

    1986-01-01

    The HM Process at the Savannah River Plant (SRP) uses 7.5% tributylphosphate in n-paraffin as an extraction solvent. During use, the solvent is altered due to hydrolysis and radiolysis, forming materials that influence product losses, produce decontamination, and separation efficiencies. Laboratory studies to improve online solvent cleaning have shown the carbonate washing, although removing residual solvent activity does not remove binding ligands that hold fission products in the solvent. Treatment of solvent by an alumina adsorption process removes binding ligands and significantly improves recycle solvent performance. Both laboratory work defining a full-scale alumina adsorption process and the use of the process to clean HM Process first cycle solvent are presented

  14. Solar panel cleaning robot

    Science.gov (United States)

    Nalladhimmu, Pavan Kumar Reddy; Priyadarshini, S.

    2018-04-01

    As the demand of electricity is increasing, there is need to using the renewable sources to produce the energy at present of power shortage, the use of solar energy could be beneficial to great extent and easy to get the maximum efficiency. There is an urgent in improving the efficiency of solar power generation. Current solar panels setups take a major power loss when unwanted obstructions cover the surface of the panels. To make solar energy more efficiency of solar array systems must be maximized efficiency evaluation of PV panels, that has been discussed with particular attention to the presence of dust on the efficiency of the PV panels have been highlighted. This paper gives the how the solar panel cleaning system works and designing of the cleaning system.

  15. Clean Energy Application Center

    Energy Technology Data Exchange (ETDEWEB)

    Freihaut, Jim [Pennsylvania State Univ., University Park, PA (United States)

    2013-09-30

    The Mid Atlantic Clean Energy Application Center (MACEAC), managed by The Penn State College of Engineering, serves the six states in the Mid-Atlantic region (Pennsylvania, New Jersey, Delaware, Maryland, Virginia and West Virginia) plus the District of Columbia. The goals of the Mid-Atlantic CEAC are to promote the adoption of Combined Heat and Power (CHP), Waste Heat Recovery (WHR) and District Energy Systems (DES) in the Mid Atlantic area through education and technical support to more than 1,200 regional industry and government representatives in the region. The successful promotion of these technologies by the MACEAC was accomplished through the following efforts; (1)The MACEAC developed a series of technology transfer networks with State energy and environmental offices, Association of Energy Engineers local chapters, local community development organizations, utilities and, Penn State Department of Architectural Engineering alumni and their firms to effectively educate local practitioners about the energy utilization, environmental and economic advantages of CHP, WHR and DES; (2) Completed assessments of the regional technical and market potential for CHP, WHR and DE technologies application in the context of state specific energy prices, state energy and efficiency portfolio development. The studies were completed for Pennsylvania, New Jersey and Maryland and included a set of incentive adoption probability models used as a to guide during implementation discussions with State energy policy makers; (3) Using the technical and market assessments and adoption incentive models, the Mid Atlantic CEAC developed regional strategic action plans for the promotion of CHP Application technology for Pennsylvania, New Jersey and Maryland; (4) The CHP market assessment and incentive adoption model information was discussed, on a continuing basis, with relevant state agencies, policy makers and Public Utility Commission organizations resulting in CHP favorable incentive

  16. Evaporator Cleaning Studies

    International Nuclear Information System (INIS)

    Wilmarth, W.R.

    1999-01-01

    Operation of the 242-16H High Level Waste Evaporator proves crucial to liquid waste management in the H-Area Tank Farm. Recent operational history of the Evaporator showed significant solid formation in secondary lines and in the evaporator pot. Additional samples remain necessary to ensure material identity in the evaporator pot. Analysis of these future samples will provide actinide partitioning information and dissolution characteristics of the solid material from the pot to ensure safe chemical cleaning

  17. Cleanly: trashducation urban system

    DEFF Research Database (Denmark)

    Reif, Inbal; Alt, Florian; Ramos, Juan David Hincapie

    Half the world's population is expected to live in urban areas by 2020. The high human density and changes in peoples' consumption habits result in an ever-increasing amount of trash that must be handled by governing bodies. Problems created by inefficient or dysfunctional cleaning services are e......, which not only motivates our research but also provides useful information on reasons and possible solutions for trash problems....

  18. Laser cleaning of Rakowicze sandstone

    NARCIS (Netherlands)

    Nijland, T.G.; Wijffels, T.J.

    2003-01-01

    Decisions about the cleaning of natural stone should always be made within the awareness of direct and indirect damage that may be the result of cleaning. During the last decade, laser cleaning of objects and monuments of natural stone has become increasingly popular. Whereas a considerable amount

  19. Who is afraid of smoking bans? An evaluation of the effects of the Spanish clean air law on expenditure at hospitality venues.

    Science.gov (United States)

    García-Villar, Jaume; López-Nicolás, Ángel

    2015-11-01

    In January 2011 Spain modified clean air legislation in force since 2006, removing all existing exceptions applicable to hospitality venues. Although this legal reform was backed by all political parties with parliamentary representation, the government's initiative was contested by the tobacco industry and its allies in the hospitality industry. One of the most voiced arguments against the reform was its potentially disruptive effect on the revenue of hospitality venues. This paper evaluates the impact of this reform on household expenditure at restaurants and bars and cafeterias. We used household expenditure micro-data for years 2006-2012 to estimate models for the probability of observing expenditures and the expected level of expenditure. We applied a before-after analysis with a wide range of controls for confounding factors and a flexible modeling of time effects in order to identify the effects of the reform. Our results suggest that the reform caused a 2% reduction in the proportion of households containing smokers but did not cause reductions in households' expenditures on restaurant services or on bars and cafeteria services.

  20. Innovation, renewable energy, and state investment: Case studies of leading clean energy funds

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ryan; Bolinger, Mark; Milford, Lewis; Porter, Kevin; Clark, Roger

    2002-09-01

    Over the last several years, many U.S. states have established clean energy funds to help support the growth of renewable energy markets. Most often funded by system-benefits charges (SBC), the 15 states that have established such funds are slated to collect nearly $3.5 billion from 1998 to 2012 for renewable energy investments. These clean energy funds are expected to have a sizable impact on the energy future of the states in which the funds are being collected and used. For many of the organizations tapped to administer these funds, however, this is a relatively new role that presents the challenge of using public funds in the most effective and innovative fashion possible. Fortunately, each state is not alone in its efforts; many other U.S. states and a number of countries are undertaking similar efforts. Early lessons are beginning to be learned by clean energy funds about how to effectively target public funds towards creating and building renewable energy markets. A number of innovative programs have already been developed that show significant leadership by U.S. states in supporting renewable energy. It is important that clean energy fund administrators learn from this emerging experience.

  1. Clean steels for fusion

    International Nuclear Information System (INIS)

    Gelles, D.S.

    1995-03-01

    Fusion energy production has an inherent advantage over fission: a fuel supply with reduced long term radioactivity. One of the leading candidate materials for structural applications in a fusion reactor is a tungsten stabilized 9% chromium Martensitic steel. This alloy class is being considered because it offers the opportunity to maintain that advantage in the reactor structure as well as provide good high temperature strength and radiation induced swelling and embrittlement resistance. However, calculations indicate that to obtain acceptable radioactivity levels within 500 years after service, clean steel will be required because the niobium impurity levels must be kept below about 2 appm and nickel, molybdenum, nitrogen, copper, and aluminum must be intentionally restricted. International efforts are addressing the problems of clean steel production. Recently, a 5,000 kg heat was vacuum induction melted in Japan using high purity commercial raw materials giving niobium levels less than 0.7 appm. This paper reviews the need for reduced long term radioactivity, defines the advantageous properties of the tungsten stabilized Martensitic steel class, and describes the international efforts to produce acceptable clean steels

  2. Field experience with KWU SG chemical cleaning process

    International Nuclear Information System (INIS)

    Odar, S.

    1989-01-01

    The ingress of corrosion products into PWR steam generators (SG's) their deposition and the subsequent concentration of salt impurities can induce a variety of mechanisms for corrosion attack on SG tubing. Already, some plants have had to replace their steam generators due to severe corrosion damage and others are seriously considering the same costly action in the near future. One of the most effective ways to counteract corrosion mechanisms and thus to reduce the likelihood of SG replacement becoming necessary is to clean the SG's and to keep them clean. For many years, the industry has been involved in developing different types of cleaning techniques. Among these, chemical cleaning has been shown to be especially effective. In this article, the KWU chemical cleaning process, for which there is considerable application experience, is described. The results of field applications will be presented together with material compatibility data and information on cleaning effectiveness. (author)

  3. Benzotriazole removal on post-Cu CMP cleaning

    International Nuclear Information System (INIS)

    Tang Jiying; Liu Yuling; Sun Ming; Fan Shiyan; Li Yan

    2015-01-01

    This work investigates systematically the effect of FA/O II chelating agent and FA/O I surfactant in alkaline cleaning solutions on benzotriazole (BTA) removal during post-Cu CMP cleaning in GLSI under the condition of static etching. The best detergent formulation for BTA removal can be determined by optimization of the experiments of single factor and compound cleaning solution, which has been further confirmed experimentally by contact angle (CA) measurements. The resulting solution with the best formulation has been measured for the actual production line, and the results demonstrate that the obtained cleaning solution can effectively and efficiently remove BTA, CuO and abrasive SiO 2 without basically causing interfacial corrosion. This work demonstrates the possibility of developing a simple, low-cost and environmentally-friendly cleaning solution to effectively solve the issues of BTA removal on post-Cu CMP cleaning in a multi-layered copper wafer. (paper)

  4. Measured energy savings and cost-effectiveness of conservation retrofits in commercial buildings

    International Nuclear Information System (INIS)

    Greely, K.M.; Harris, J.P.; Hatcher, A.M.

    1990-01-01

    In this study, the authors examine the measured savings and cost-effectiveness of 447 commercial retrofit projects in the US, Canada, and Europe, representing over 1,700 buildings. For these projects, they examine savings and cost-effectiveness by building type and retrofit strategy, savings from individual measures, peak electric demand savings, comparisons of measured vs. predicted savings, and the persistence of savings in the years following a retrofit. Median annual site energy savings amounted to 20 kBtu/ft 2 , or 18% of whole-building usage; median retrofit cost was $0.56/ft 2 (1988 $), the median payback time was 3.1 years, and the median cost of conserved energy was $3.10/site MBtu. When examined by retrofit strategy, they found that projects with only HVAC and/or lighting retrofits had median payback times of one to three years, while those affecting the building shell, either alone or in combination with other types of measures, had payback times of five or more years. Projects in which only maintenance practices were changed typically saved 12% of their pre-retrofit consumption, often using in-house labor. Their research suggests that, despite significant savings and short payback times for the majority of projects, optimum savings are often not being achieved, due to limited owner willingness to invest in all cost-effective measures, as well as to improper retrofit installation and/or maintenance. A comprehensive understanding of energy management as a process is needed, including both inspection and commissioning of installed retrofits and ongoing tracking of energy consumption as an indicator of operating problems

  5. Annual mean effective dose of Slovak population due to natural radioactivity of building materials

    International Nuclear Information System (INIS)

    Cabanekova, H.

    2006-01-01

    volume of the samples. For the typical building materials of Slovak construction industry has been estimated the average volume activity (brick: 40 K: 660.1 Bq.kg-1, 226 Ra: 63.5 Bq.kg-1, 232 Th: 71.3 Bq.kg-1, A ekv : 216.3 Bq.kg-1; concrete: 40 K: 322.6 Bq.kg-1, 226 Ra: 46.1 Bq.kg-1, 232 Th: 29.0 Bq.kg-1, A ekv : 216,3 Bq.kg-1). Indoor radiation exposure of the population due to external exposure from natural radionuclides has been determined for a standard room (5 x 5 x 2.8 m) and for assuming that the mean occupancy indoors is 80%. Using a special calculation model there was received the annual mean effective dose from natural radionuclides in two typical Slovak dwellings for brick houses: 0.87 mSv.y-1 and for houses from concrete panels: 0.31 mSv.y-1. (author)

  6. RESULTS OF A PILOT FIELD STUDY TO EVALUATE THE EFFECTIVENESS OF CLEANING RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS AND THE IMPACT ON INDOOR AIR QUALITY AND SYSTEM PERFORMANCE

    Science.gov (United States)

    The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...

  7. Seismic Response of 3D Steel Buildings considering the Effect of PR Connections and Gravity Frames

    Directory of Open Access Journals (Sweden)

    Alfredo Reyes-Salazar

    2014-01-01

    Full Text Available The nonlinear seismic responses of 3D steel buildings with perimeter moment resisting frames (PMRF and interior gravity frames (IGF are studied explicitly considering the contribution of the IGF. The effect on the structural response of the stiffness of the beam-to-column connections of the IGF, which is usually neglected, is also studied. It is commonly believed that the flexibility of shear connections is negligible and that 2D models can be used to properly represent 3D real structures. The results of the study indicate, however, that the moments developed on columns of IGF can be considerable and that modeling buildings as plane frames may result in very conservative designs. The contribution of IGF to the lateral structural resistance may be significant. The contribution increases when their connections are assumed to be partially restrained (PR. The incremented participation of IGF when the stiffness of their connections is considered helps to counteract the no conservative effect that results in practice when lateral seismic loads are not considered in IGF while designing steel buildings with PMRF. Thus, if the structural system under consideration is used, the three-dimensional model should be used in seismic analysis and the IGF and the stiffness of their connections should be considered as part of the lateral resistance system.

  8. Seismic Response of 3D Steel Buildings considering the Effect of PR Connections and Gravity Frames

    Science.gov (United States)

    Haldar, Achintya; López-Barraza, Arturo; Rivera-Salas, J. Luz

    2014-01-01

    The nonlinear seismic responses of 3D steel buildings with perimeter moment resisting frames (PMRF) and interior gravity frames (IGF) are studied explicitly considering the contribution of the IGF. The effect on the structural response of the stiffness of the beam-to-column connections of the IGF, which is usually neglected, is also studied. It is commonly believed that the flexibility of shear connections is negligible and that 2D models can be used to properly represent 3D real structures. The results of the study indicate, however, that the moments developed on columns of IGF can be considerable and that modeling buildings as plane frames may result in very conservative designs. The contribution of IGF to the lateral structural resistance may be significant. The contribution increases when their connections are assumed to be partially restrained (PR). The incremented participation of IGF when the stiffness of their connections is considered helps to counteract the no conservative effect that results in practice when lateral seismic loads are not considered in IGF while designing steel buildings with PMRF. Thus, if the structural system under consideration is used, the three-dimensional model should be used in seismic analysis and the IGF and the stiffness of their connections should be considered as part of the lateral resistance system. PMID:24995357

  9. Evidence on dynamic effects in the water content – water potential relation of building materials

    DEFF Research Database (Denmark)

    Scheffler, Gregor Albrecht; Plagge, Rudolf

    2008-01-01

    static and dynamic moisture storage data and the more pronounced was the corresponding dynamic hysteresis. The paper thus provides clear experimental evidence on dynamic effects in the water content – water potential relation of building materials. By that, data published by previous authors as Topp et......Hygrothermal simulation has become a widely applied tool for the design and assessment of building structures under possible indoor and outdoor climatic conditions. One of the most important prerequisites of such simulations is reliable material data. Different approaches exist here to derive...... the required material functions, i.e. the moisture storage characteristic and the liquid water conductivity, from measured basic properties. The current state of the art in material modelling as well as the corresponding transport theory implies that the moisture transport function is unique...

  10. Qualification test of chemical cleaning for secondary side of steam generator in Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zhang Mengqin; Zhang Shufeng; Yu Jinghua; Hou Shufeng

    1997-07-01

    The chemical cleaning technique for removing sludge on the secondary side in Qinshan Nuclear Power Plant has been qualified. The chemical cleaning process will carry out during shutdown refuelling. The qualification test has studied the effect of chemical cleaning agent component, cleaning time on dissolution effectiveness of sludge (Fe 3 O 4 ) and to evaluate corrosion situation of main materials of SG in the cleaning process. The main component of cleaning agent is EDTA. The cleaning temperature is 20∼30 degree C. It is determined that allowable remains amount of cleaning agent (EDTA). The technique of cleaning, rinse, passivation for the chemical cleaning in Qinshan Nuclear Power Plant has been made. The qualification test shown that the technique can dissolve Fe 3 O 4 >1 g/L, the corrosion of materials is in allowable value, the allowable remains of EDTA is <0.01%. The technique character is static, ambient temperature. (9 refs., 12 tabs.)

  11. Clean energy deployment: addressing financing cost

    International Nuclear Information System (INIS)

    Ameli, Nadia; Kammen, Daniel M

    2012-01-01

    New methods are needed to accelerate clean energy policy adoption. To that end, this study proposes an innovative financing scheme for renewable and energy efficiency deployment. Financing barriers represent a notable obstacle for energy improvements and this is particularly the case for low income households. Implementing a policy such as PACE—property assessed clean energy—allows for the provision of upfront funds for residential property owners to install electric and thermal solar systems and make energy efficiency improvements to their buildings. This paper will inform the design of better policies tailored to the creation of the appropriate conditions for such investments to occur, especially in those countries where most of the population belongs to the low–middle income range facing financial constraints. (letter)

  12. Clean Energy Works Oregon Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Andria [City of Portland; Cyr, Shirley [Clean Energy Works

    2013-12-31

    In April 2010, the City of Portland received a $20 million award from the U.S. Department of Energy, as part of the Energy Efficiency and Conservation Block Grant program. This award was appropriated under the American Recovery and Reinvestment Act (ARRA), passed by President Obama in 2009. DOE’s program became known as the Better Buildings Neighborhood Program (BBNP). The BBNP grant objectives directed the City of Portland Bureau of Planning and Sustainability (BPS) as the primary grantee to expand the BPS-led pilot program, Clean Energy Works Portland, into Clean Energy Works Oregon (CEWO), with the mission to deliver thousands of home energy retrofits, create jobs, save energy and reduce carbon dioxide emissions.The Final Technical Report explores the successes and lessons learned from the first 3 years of program implementation.

  13. Clean energy deployment: addressing financing cost

    Science.gov (United States)

    Ameli, Nadia; Kammen, Daniel M.

    2012-09-01

    New methods are needed to accelerate clean energy policy adoption. To that end, this study proposes an innovative financing scheme for renewable and energy efficiency deployment. Financing barriers represent a notable obstacle for energy improvements and this is particularly the case for low income households. Implementing a policy such as PACE—property assessed clean energy—allows for the provision of upfront funds for residential property owners to install electric and thermal solar systems and make energy efficiency improvements to their buildings. This paper will inform the design of better policies tailored to the creation of the appropriate conditions for such investments to occur, especially in those countries where most of the population belongs to the low-middle income range facing financial constraints.

  14. G20 Clean Energy, and Energy Efficiency Deployment and Policy Progress

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    G-20 Clean Energy, and Energy Efficiency Deployment and Policy Progress, a report prepared by the International Energy Agency (IEA) in collaboration with the G-20 Clean Energy and Energy Efficiency Working Group, provides an overview of clean energy and energy efficiency technology deployment and summarises support policies in place across G-20 countries. The report highlights that while clean energy technology deployment has made steady progress and energy efficiency improvements have been made, continued reliance on fossil fuels to meet growth in global energy demand presents a significant challenge. Scaling-up the deployment of renewable energy, in addition to improving end-use efficiency, enhancing the efficiency of fossil fuel based power generation, and supporting the widespread deployment of CCS will, therefore, also be crucial aspects of the transition to a cleaner energy future. Because the G-20 group of countries represent close to 80% of energy-related CO2 emissions, by developing and deploying energy efficiency and clean energy technologies, they are presented with a unique opportunity to make collective progress in transitioning the global energy system. IEA Deputy Executive Director Richard Jones emphasised the importance of G-20 efforts, saying, 'The IEA welcomes this important collaboration with the G-20. Enhanced deployment of clean energy technologies and of energy efficiency improvements offers energy security and environmental benefits. It will also enable cost savings over the medium and long term -- an aspect that is particularly relevant at a time of economic uncertainty. We believe that enhanced policy assessment and analysis, building on this initial report, will enable governments to take more cost effective and efficient policy decisions.' This report was issued on the authority of the IEA Executive Director, it does not necessarily represent the views of IEA Member countries or the G20.

  15. G20 Clean Energy, and Energy Efficiency Deployment and Policy Progress

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    G-20 Clean Energy, and Energy Efficiency Deployment and Policy Progress, a report prepared by the International Energy Agency (IEA) in collaboration with the G-20 Clean Energy and Energy Efficiency Working Group, provides an overview of clean energy and energy efficiency technology deployment and summarises support policies in place across G-20 countries. The report highlights that while clean energy technology deployment has made steady progress and energy efficiency improvements have been made, continued reliance on fossil fuels to meet growth in global energy demand presents a significant challenge. Scaling-up the deployment of renewable energy, in addition to improving end-use efficiency, enhancing the efficiency of fossil fuel based power generation, and supporting the widespread deployment of CCS will, therefore, also be crucial aspects of the transition to a cleaner energy future. Because the G-20 group of countries represent close to 80% of energy-related CO2 emissions, by developing and deploying energy efficiency and clean energy technologies, they are presented with a unique opportunity to make collective progress in transitioning the global energy system. IEA Deputy Executive Director Richard Jones emphasised the importance of G-20 efforts, saying, 'The IEA welcomes this important collaboration with the G-20. Enhanced deployment of clean energy technologies and of energy efficiency improvements offers energy security and environmental benefits. It will also enable cost savings over the medium and long term -- an aspect that is particularly relevant at a time of economic uncertainty. We believe that enhanced policy assessment and analysis, building on this initial report, will enable governments to take more cost effective and efficient policy decisions.' This report was issued on the authority of the IEA Executive Director, it does not necessarily represent the views of IEA Member countries or the G20.

  16. Evaluating the Effect of Nuclear Power Plant Buildings on the Atmospheric Dispersion Behavior of Released Radioactive Materials

    International Nuclear Information System (INIS)

    Nassar, N.N.; Tawfik, F.S.; Agamy, S.A.; Nagla, T.F.

    2017-01-01

    One of the most important principles in air pollution is to minimize the release of pollutants to the atmosphere, deposition on the ground and promote sufficient dilution of released pollutants within the atmosphere. Building down wash describes the effect that wind flowing over or around buildings create a cavity of reticulating winds in the are a near the buildings. These cavities cause increased vertical dispersion of plumes emitted from stacks on or near the buildings . Often it leads to elevated concentrations downwind of affected stacks. The aim of this work is to evaluate the effect of the building down wash phenomena on the atmospheric dispersion behavior of released radioactive materials from NPP. In this study, a hypothetical scenario is presented involving a point source with varying stack parameters and rectangular shaped buildings (Mille stone Nuclear Power Plant) using meteorological parameters of a chosen day. The concentrations of assumed released radionuclides, taking into consideration the building down wash effect and without are calculated using the AERMOD Model taking into consideration the effect of the type of atmospheric stability class. Also the analysis includes the model predictions for the highest 1-hour cavity concentration. The results show that the size of the cavity zone is not affected by the type of stability class, but is affected by the stack location and buildings shape. On other hand, the distance at which the plume touches the ground is affected by the type of stability class, the stack location and buildings shape. So, strategies for locating buildings need to be considered to maximize dispersion when planning for constructing several reactors and accessory buildings at a nuclear site

  17. Effects of newly designed hospital buildings on staff perceptions : a pre-post study to validate design decisions

    NARCIS (Netherlands)

    Schreuder, E.J.A.; Heel, L. van; Goedhart, R.; Dusseldorp, E.; Schraagen, J.M.C.; Burdorf, A.

    2015-01-01

    Objective: This study investigates effects of the newly built nonpatient-related buildings of a large university medical center on staff perceptions and whether the design objectives were achieved. Background: The medical center is gradually renewing its hospital building area of 200,000 m.(2) This

  18. A Difference-In-Differences Study of the Effects of a New Abandoned Building Remediation Strategy on Safety

    Science.gov (United States)

    Michelle C. Kondo; Danya Keene; Bernadette C. Hohl; John M. MacDonald; Charles C. Branas

    2015-01-01

    Vacant and abandoned buildings pose significant challenges to the health and safety of communities. In 2011 the City of Philadelphia began enforcing a Doors and Windows Ordinance that required property owners of abandoned buildings to install working doors and windows in all structural openings or face significant fines. We tested the effects of the new ordinance on...

  19. Maintenance measures for preservation and recovery of permeable pavement surface infiltration rate--The effects of street sweeping, vacuum cleaning, high pressure washing, and milling.

    Science.gov (United States)

    Winston, Ryan J; Al-Rubaei, Ahmed M; Blecken, Godecke T; Viklander, Maria; Hunt, William F

    2016-03-15

    The surface infiltration rates (SIR) of permeable pavements decline with time as sediment and debris clog pore spaces. Effective maintenance techniques are needed to ensure the hydraulic functionality and water quality benefits of this stormwater control. Eight different small-scale and full-scale maintenance techniques aimed at recovering pavement permeability were evaluated at ten different permeable pavement sites in the USA and Sweden. Maintenance techniques included manual removal of the upper 2 cm of fill material, mechanical street sweeping, regenerative-air street sweeping, vacuum street sweeping, hand-held vacuuming, high pressure washing, and milling of porous asphalt. The removal of the upper 2 cm of clogging material did not significantly improve the SIR of concrete grid paves (CGP) and permeable interlocking concrete pavers (PICP) due to the inclusion of fines in the joint and bedding stone during construction, suggesting routine maintenance cannot overcome improper construction. For porous asphalt maintenance, industrial hand-held vacuum cleaning, pressure washing, and milling were increasingly successful at recovering the SIR. Milling to a depth of 2.5 cm nearly restored the SIR for a 21-year old porous asphalt pavement to like-new conditions. For PICP, street sweepers employing suction were shown to be preferable to mechanical sweepers; additionally, maintenance efforts may become more intensive over time to maintain a threshold SIR, as maintenance was not 100% effective at removing clogging material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Green signalling effects in the market for energy-efficient residential buildings

    International Nuclear Information System (INIS)

    Fuerst, Franz; Oikarinen, Elias; Harjunen, Oskari

    2016-01-01

    Highlights: • Energy efficiency (EE) levels are hypothesised to affect house transaction prices. • We estimate a hedonic model using Energy Performance Certificates from Finland. • A price premium is found for the most energy-efficient properties. • The empirical results are suggestive of a green signalling effect. • Demand for EE high performers appears to be segmented from lower tiers. - Abstract: Empirical evidence from recent studies suggests that the price premium on energy-efficient buildings is potentially higher than the pure capitalisation of energy savings but the empirical evidence on the size of the non-savings components is scant. This study aims to fill this research gap by investigating whether the mandatory energy efficiency ratings for residential properties imply benefits that go beyond energy savings. Using a sample of several thousand apartment transactions from Helsinki, Finland, we first test if higher ratings were significantly associated with higher prices. In addition to a large number of property and neighbourhood characteristics, this dataset contains information on building-level energy usage which allows us to distinguish between the cost savings effect of energy consumption and the value of more intangible factors associated with the energy label. The hedonic model yields a statistically significant 3.3% price premium for apartments in the top three energy-efficiency categories and 1.5% when a set of detailed neighbourhood characteristics are included. When maintenance costs containing energy usage costs are added, a robust and significant price premium of 1.3% persists whereas no differentiation is found for the medium and lower rating categories. These findings may be indicative of energy-efficient buildings having signalling value – and therefore an additional incentive to invest in such buildings – for ‘green’ consumers. However, a favourable energy rating did not appear to speed up the sales process in the